From d79605f406d80fc843393ad390fe61f1dd991fcb Mon Sep 17 00:00:00 2001 From: "Lerond, Jeremy" Date: Mon, 16 Jan 2023 22:27:31 -0800 Subject: [PATCH 01/45] Remove BT dependency for space type data lookup; Simplify medium office space types and space type assumptions for 90.1-2004. --- data/geometry/ASHRAEMediumOffice.osm | 10 +- .../standards/Standards.SpaceType.rb | 4 - .../data/ashrae_90_1_2004.spc_typ.json | 22901 +--------------- test/doe_prototype/test_medium_office.rb | 4 +- 4 files changed, 356 insertions(+), 22563 deletions(-) diff --git a/data/geometry/ASHRAEMediumOffice.osm b/data/geometry/ASHRAEMediumOffice.osm index b377f9c93f..7e6984e7f4 100644 --- a/data/geometry/ASHRAEMediumOffice.osm +++ b/data/geometry/ASHRAEMediumOffice.osm @@ -4452,30 +4452,30 @@ OS:ZoneHVAC:EquipmentList, OS:SpaceType, {34e15ad4-259e-4af7-9d47-f9dfb6b78bc5}, !- Handle - Office WholeBuilding - Md Office, !- Name + Office, !- Name , !- Default Construction Set Name , !- Default Schedule Set Name {507a5052-c6fa-4e80-96ea-d8413460cc49}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Office, !- Standards Building Type - WholeBuilding - Md Office; !- Standards Space Type + Office; !- Standards Space Type OS:Rendering:Color, {507a5052-c6fa-4e80-96ea-d8413460cc49}, !- Handle - Office WholeBuilding - Md Office, !- Name + Office, !- Name 120, !- Rendering Red Value 230, !- Rendering Green Value 199; !- Rendering Blue Value OS:SpaceType, {197e68ab-195b-4ad3-9452-c3b5ed7c640d}, !- Handle - Plenum, !- Name + Corridor, !- Name , !- Default Construction Set Name , !- Default Schedule Set Name , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name , !- Standards Building Type - Plenum; !- Standards Space Type + Corridor; !- Standards Space Type OS:SubSurface, {bc65ca32-39bf-48a6-a1cd-d61dc5fd3db7}, !- Handle diff --git a/lib/openstudio-standards/standards/Standards.SpaceType.rb b/lib/openstudio-standards/standards/Standards.SpaceType.rb index 6d94eaa50b..bc06d0abc3 100644 --- a/lib/openstudio-standards/standards/Standards.SpaceType.rb +++ b/lib/openstudio-standards/standards/Standards.SpaceType.rb @@ -6,9 +6,6 @@ class Standard # @param space_type [OpenStudio::Model::SpaceType] space type object # @return [hash] hash of internal loads for different load types def space_type_get_standards_data(space_type) - standards_building_type = if space_type.standardsBuildingType.is_initialized - space_type.standardsBuildingType.get - end standards_space_type = if space_type.standardsSpaceType.is_initialized space_type.standardsSpaceType.get end @@ -16,7 +13,6 @@ def space_type_get_standards_data(space_type) # populate search hash search_criteria = { 'template' => template, - 'building_type' => standards_building_type, 'space_type' => standards_space_type } diff --git a/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json b/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json index 27559c6843..cc9c62ef35 100644 --- a/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +++ b/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json @@ -1,22555 +1,352 @@ { "space_types": [ - { - "template": "90.1-2004", - "building_type": "Any", - "space_type": "Plenum", - "lighting_standard": null, - "lighting_primary_space_type": null, - "lighting_secondary_space_type": null, - "lighting_per_area": null, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": null, - "lighting_fraction_radiant": null, - "lighting_fraction_visible": null, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": null, - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": null, - "electric_equipment_fraction_latent": null, - "electric_equipment_fraction_radiant": null, - "electric_equipment_fraction_lost": null, - "electric_equipment_schedule": null, - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": null, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": null, - "ventilation_primary_space_type": null, - "ventilation_secondary_space_type": null, - "ventilation_per_area": null, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": null, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": null, - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": null, - "cooling_setpoint_schedule": null, - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": null - }, - { - "template": "90.1-2004", - "building_type": "College", - "space_type": "College - Art Classroom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Classroom/lecture/training", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.4, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": null, - "lighting_fraction_radiant": null, - "lighting_fraction_visible": null, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": null, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "College BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.929, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "College BLDG_EQUIP_SCH_Base", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 20.0, - "occupancy_schedule": "College BLDG_Studio_OCC_SCH", - "occupancy_activity_schedule": "College ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Education", - "ventilation_secondary_space_type": "Classroom", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": null, - "infiltration_per_exterior_wall_area": 0.2016, - "infiltration_air_changes": null, - "infiltration_schedule": "College INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "College HTGSETP_SCH", - "cooling_setpoint_schedule": "College CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": "College BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_196_120" - }, - { - "template": "90.1-2004", - "building_type": "College", - "space_type": "College - Classroom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Classroom", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.4, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": null, - "lighting_fraction_radiant": null, - "lighting_fraction_visible": null, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": null, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "College BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.929, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "College BLDG_EQUIP_SCH_Base", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 65.0, - "occupancy_schedule": "College BLDG_Class_OCC_SCH", - "occupancy_activity_schedule": "College ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Education", - "ventilation_secondary_space_type": "Classroom", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": null, - "infiltration_per_exterior_wall_area": 0.2016, - "infiltration_air_changes": null, - "infiltration_schedule": "College INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "College HTGSETP_SCH", - "cooling_setpoint_schedule": "College CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": "College BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_196_120" - }, - { - "template": "90.1-2004", - "building_type": "College", - "space_type": "College - Conference", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Conference", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.3, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": null, - "lighting_fraction_radiant": null, - "lighting_fraction_visible": null, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": null, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "College BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "College BLDG_EQUIP_SCH_Base", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 50.0, - "occupancy_schedule": "College BLDG_OCC_SCH", - "occupancy_activity_schedule": "College ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Conference rooms", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": null, - "infiltration_per_exterior_wall_area": 0.2016, - "infiltration_air_changes": null, - "infiltration_schedule": "College INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "College HTGSETP_SCH", - "cooling_setpoint_schedule": "College CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": "College BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_196_120" - }, - { - "template": "90.1-2004", - "building_type": "College", - "space_type": "College - Corridor", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Corridor", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": null, - "lighting_fraction_radiant": null, - "lighting_fraction_visible": null, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": null, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "College BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.37, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "College BLDG_EQUIP_SCH_Base", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": null, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": null, - "infiltration_per_exterior_wall_area": 0.2016, - "infiltration_air_changes": null, - "infiltration_schedule": "College INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "College HTGSETP_SCH", - "cooling_setpoint_schedule": "College CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": "College BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_31" - }, - { - "template": "90.1-2004", - "building_type": "College", - "space_type": "College - Elevator Shaft", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "ElevatorCore", - "lighting_secondary_space_type": null, - "lighting_per_area": null, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": null, - "lighting_fraction_radiant": null, - "lighting_fraction_visible": null, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": null, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "College ELEV_LIGHT_FAN_SCH_24_7", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "occupancy_per_area": null, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Elevators", - "ventilation_per_area": 1.0, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": null, - "infiltration_per_exterior_wall_area": 0.2016, - "infiltration_air_changes": null, - "infiltration_schedule": "College INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": null, - "cooling_setpoint_schedule": null, - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": "College BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "41_31_169" - }, - { - "template": "90.1-2004", - "building_type": "College", - "space_type": "College - Entrance Lobby", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Lobby - elevator", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.3, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": null, - "lighting_fraction_radiant": null, - "lighting_fraction_visible": null, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": null, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "College BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.37, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "College BLDG_EQUIP_SCH_Base", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 10.0, - "occupancy_schedule": "College BLDG_OCC_SCH", - "occupancy_activity_schedule": "College ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Reception areas", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": null, - "infiltration_per_exterior_wall_area": 0.2016, - "infiltration_air_changes": null, - "infiltration_schedule": "College INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "College HTGSETP_SCH", - "cooling_setpoint_schedule": "College CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": "College BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "College", - "space_type": "College - Laboratory", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Lab", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.4, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": null, - "lighting_fraction_radiant": null, - "lighting_fraction_visible": null, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": null, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "College BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 4.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "College BLDG_EQUIP_SCH_Base", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 25.0, - "occupancy_schedule": "College BLDG_Lab_OCC_SCH", - "occupancy_activity_schedule": "College ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "college/university-laboratories", - "ventilation_secondary_space_type": null, - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": null, - "infiltration_per_exterior_wall_area": 0.2016, - "infiltration_air_changes": null, - "infiltration_schedule": "College INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "College HTGSETP_SCH", - "cooling_setpoint_schedule": "College CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": "College BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "204_120_230" - }, - { - "template": "90.1-2004", - "building_type": "College", - "space_type": "College - Lecture Hall", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Auditorium", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.4, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": null, - "lighting_fraction_radiant": null, - "lighting_fraction_visible": null, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": null, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "College BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.929, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "College BLDG_EQUIP_SCH_Base", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 65.0, - "occupancy_schedule": "College BLDG_Lecture_OCC_SCH", - "occupancy_activity_schedule": "College ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Education", - "ventilation_secondary_space_type": "Classroom", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": null, - "infiltration_per_exterior_wall_area": 0.2016, - "infiltration_air_changes": null, - "infiltration_schedule": "College INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "College HTGSETP_SCH", - "cooling_setpoint_schedule": "College CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": "College BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_196_120" - }, - { - "template": "90.1-2004", - "building_type": "College", - "space_type": "College - Lounge", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Lounge", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.2, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": null, - "lighting_fraction_radiant": null, - "lighting_fraction_visible": null, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": null, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "College BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 7.15, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "College BLDG_EQUIP_SCH_Base", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 25.0, - "occupancy_schedule": "College BLDG_Cafe_OCC_SCH", - "occupancy_activity_schedule": "College ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Food and Beverage Service", - "ventilation_secondary_space_type": "Cafeteria, fast food", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": null, - "infiltration_per_exterior_wall_area": 0.2016, - "infiltration_air_changes": null, - "infiltration_schedule": "College INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "College HTGSETP_SCH", - "cooling_setpoint_schedule": "College CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": "College BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "College", - "space_type": "College - Media Center", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Auditorium", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.2, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": null, - "lighting_fraction_radiant": null, - "lighting_fraction_visible": null, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": null, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "College BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.93, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "College BLDG_EQUIP_SCH_Base", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 10.0, - "occupancy_schedule": "College BLDG_Lecture_OCC_SCH", - "occupancy_activity_schedule": "College ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Education", - "ventilation_secondary_space_type": "Libraries", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": null, - "infiltration_per_exterior_wall_area": 0.2016, - "infiltration_air_changes": null, - "infiltration_schedule": "College INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "College HTGSETP_SCH", - "cooling_setpoint_schedule": "College CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": "College BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_196_121" - }, - { - "template": "90.1-2004", - "building_type": "College", - "space_type": "College - Office", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Office - enclosed", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": null, - "lighting_fraction_radiant": null, - "lighting_fraction_visible": null, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": null, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "College BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "College BLDG_EQUIP_SCH_Base", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.0, - "occupancy_schedule": "College BLDG_OCC_SCH_Offices", - "occupancy_activity_schedule": "College ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Office space", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": null, - "infiltration_per_exterior_wall_area": 0.2016, - "infiltration_air_changes": null, - "infiltration_schedule": "College INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "College HTGSETP_SCH", - "cooling_setpoint_schedule": "College CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": "College BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "College", - "space_type": "College - Restroom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Restroom", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": null, - "lighting_fraction_radiant": null, - "lighting_fraction_visible": null, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": null, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "College BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.37, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "College BLDG_EQUIP_SCH_Base", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": null, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)", - "ventilation_per_area": 0.96, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": null, - "infiltration_per_exterior_wall_area": 0.2016, - "infiltration_air_changes": null, - "infiltration_schedule": "College INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "College HTGSETP_SCH_SETBACK", - "cooling_setpoint_schedule": "College CLGSETP_SCH_SETUP", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": "College BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_169_31" - }, - { - "template": "90.1-2004", - "building_type": "College", - "space_type": "College - Stairs", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Stair", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.6, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": null, - "lighting_fraction_radiant": null, - "lighting_fraction_visible": null, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": null, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "College BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "occupancy_per_area": null, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": null, - "infiltration_per_exterior_wall_area": 0.2016, - "infiltration_air_changes": null, - "infiltration_schedule": "College INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "College HTGSETP_SCH", - "cooling_setpoint_schedule": "College CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": "College BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "College", - "space_type": "College - Storage", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Storage", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.8, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": null, - "lighting_fraction_radiant": null, - "lighting_fraction_visible": null, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": null, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "College BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "occupancy_per_area": null, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", - "ventilation_secondary_space_type": "Storage rooms", - "ventilation_per_area": 0.15, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": null, - "infiltration_per_exterior_wall_area": 0.2016, - "infiltration_air_changes": null, - "infiltration_schedule": "College INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "College HTGSETP_SCH", - "cooling_setpoint_schedule": "College CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": "College BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_149_230" - }, - { - "template": "90.1-2004", - "building_type": "College", - "space_type": "College - Utility", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Electrical/Mechanical", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": null, - "lighting_fraction_radiant": null, - "lighting_fraction_visible": null, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": null, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "College BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.37, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "College BLDG_EQUIP_SCH_Base", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": null, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": null, - "infiltration_per_exterior_wall_area": 0.2016, - "infiltration_air_changes": null, - "infiltration_schedule": "College INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "College HTGSETP_SCH_SETBACK", - "cooling_setpoint_schedule": "College CLGSETP_SCH_SETUP", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": "College BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "41_31_169" - }, - { - "template": "90.1-2004", - "building_type": "Courthouse", - "space_type": "Courthouse - Break Room", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Lounge/Recreation", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.2, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Courthouse GENERAL_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 4.46, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Courthouse BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.0, - "occupancy_schedule": "Courthouse OFFICE_OCC_SCH", - "occupancy_activity_schedule": "Courthouse ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Reception Areas", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Courthouse_INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Courthouse HTGSETP", - "cooling_setpoint_schedule": "Courthouse CLGSETP", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "Courthouse BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "Courthouse", - "space_type": "Courthouse - Cell", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", - "lighting_secondary_space_type": "Confinement Cells", - "lighting_per_area": 0.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Courthouse GENERAL_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": null, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Courthouse BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 25.0, - "occupancy_schedule": "Courthouse CELL_OCC_SCH", - "occupancy_activity_schedule": "Courthouse ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Correctional Facilities", - "ventilation_secondary_space_type": "Cell", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Courthouse_INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Courthouse HTGSETP", - "cooling_setpoint_schedule": "Courthouse CLGSETP", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "Courthouse", - "space_type": "Courthouse - Conference", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Conference/Meeting/Multipurpose", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.3, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Courthouse GENERAL_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.37, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Courthouse BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 50.0, - "occupancy_schedule": "Courthouse OFFICE_OCC_SCH", - "occupancy_activity_schedule": "Courthouse ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Conference Rooms", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Courthouse_INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Courthouse HTGSETP", - "cooling_setpoint_schedule": "Courthouse CLGSETP", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_196_120" - }, - { - "template": "90.1-2004", - "building_type": "Courthouse", - "space_type": "Courthouse - Corridor", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Corridor/Transition", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Courthouse GENERAL_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.16, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Courthouse BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "Courthouse OFFICE_OCC_SCH", - "occupancy_activity_schedule": "Courthouse ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Courthouse_INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Courthouse HTGSETP", - "cooling_setpoint_schedule": "Courthouse CLGSETP", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_31" - }, - { - "template": "90.1-2004", - "building_type": "Courthouse", - "space_type": "Courthouse - Courtroom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", - "lighting_secondary_space_type": "Courtroom", - "lighting_per_area": 1.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Courthouse COURTROOM_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": null, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Courthouse BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 70.0, - "occupancy_schedule": "Courthouse COURTROOM_OCC_SCH", - "occupancy_activity_schedule": "Courthouse ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Education", - "ventilation_secondary_space_type": "Classroom", - "ventilation_per_area": 0.0, - "ventilation_per_person": 16.95, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Courthouse_INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Courthouse HTGSETP", - "cooling_setpoint_schedule": "Courthouse CLGSETP", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "Courthouse", - "space_type": "Courthouse - Courtroom Waiting", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.3, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Courthouse COURTROOM_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.07, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Courthouse BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 10.0, - "occupancy_schedule": "Courthouse COURTROOM_OCC_SCH", - "occupancy_activity_schedule": "Courthouse ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Reception Areas", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Courthouse_INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Courthouse HTGSETP", - "cooling_setpoint_schedule": "Courthouse CLGSETP", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "Courthouse", - "space_type": "Courthouse - Elevator Lobby", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.3, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Courthouse GENERAL_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.07, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Courthouse BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 10.0, - "occupancy_schedule": "Courthouse OFFICE_OCC_SCH", - "occupancy_activity_schedule": "Courthouse ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Reception Areas", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Courthouse_INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Courthouse HTGSETP", - "cooling_setpoint_schedule": "Courthouse CLGSETP", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "Courthouse", - "space_type": "Courthouse - Elevator Shaft", - "lighting_standard": null, - "lighting_primary_space_type": null, - "lighting_secondary_space_type": null, - "lighting_per_area": null, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": null, - "lighting_fraction_radiant": null, - "lighting_fraction_visible": null, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": null, - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": null, - "electric_equipment_fraction_latent": null, - "electric_equipment_fraction_radiant": null, - "electric_equipment_fraction_lost": null, - "electric_equipment_schedule": null, - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": null, - "ventilation_primary_space_type": null, - "ventilation_secondary_space_type": null, - "ventilation_per_area": null, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Courthouse_INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": null, - "cooling_setpoint_schedule": null, - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "41_31_169" - }, - { - "template": "90.1-2004", - "building_type": "Courthouse", - "space_type": "Courthouse - Entrance Lobby", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.3, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Courthouse GENERAL_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.07, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Courthouse BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 10.0, - "occupancy_schedule": "Courthouse OFFICE_OCC_SCH", - "occupancy_activity_schedule": "Courthouse ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Reception Areas", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Courthouse_INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Courthouse HTGSETP", - "cooling_setpoint_schedule": "Courthouse CLGSETP", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "Courthouse", - "space_type": "Courthouse - Judges Chamber", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", - "lighting_secondary_space_type": "Judges Chambers", - "lighting_per_area": 1.3, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Courthouse JUDGES_CHAMBER_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.64, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Courthouse BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.0, - "occupancy_schedule": "Courthouse JUDGES_CHAMBER_OCC_SCH", - "occupancy_activity_schedule": "Courthouse ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Office space", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Courthouse_INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Courthouse HTGSETP", - "cooling_setpoint_schedule": "Courthouse CLGSETP", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "Courthouse", - "space_type": "Courthouse - Jury Assembly", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Classroom/Lecture/Training", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.4, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Courthouse JURY_ASSEMBLY_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": null, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Courthouse BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 120.0, - "occupancy_schedule": "Courthouse JURY_ASSEMBLY_OCC_SCH", - "occupancy_activity_schedule": "Courthouse ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Assembly rooms", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Courthouse_INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Courthouse HTGSETP", - "cooling_setpoint_schedule": "Courthouse CLGSETP", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "Courthouse", - "space_type": "Courthouse - Jury Deliberation", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Conference/Meeting/Multipurpose", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.3, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Courthouse JURY_DELIBERATION_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.37, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Courthouse BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 50.0, - "occupancy_schedule": "Courthouse JURY_DELIBERATION_OCC_SCH", - "occupancy_activity_schedule": "Courthouse ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Conference Rooms", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Courthouse_INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Courthouse HTGSETP", - "cooling_setpoint_schedule": "Courthouse CLGSETP", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "Courthouse", - "space_type": "Courthouse - Library", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Library", - "lighting_secondary_space_type": "Reading Area", - "lighting_per_area": 1.2, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Courthouse GENERAL_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": null, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Courthouse BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 10.0, - "occupancy_schedule": "Courthouse OFFICE_OCC_SCH", - "occupancy_activity_schedule": "Courthouse ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Education", - "ventilation_secondary_space_type": "Libraries", - "ventilation_per_area": 0.0, - "ventilation_per_person": 16.95, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Courthouse_INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Courthouse HTGSETP", - "cooling_setpoint_schedule": "Courthouse CLGSETP", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "Courthouse", - "space_type": "Courthouse - Office", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Office-Enclosed", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Courthouse GENERAL_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.64, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Courthouse BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.0, - "occupancy_schedule": "Courthouse OFFICE_OCC_SCH", - "occupancy_activity_schedule": "Courthouse ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Office space", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Courthouse_INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Courthouse HTGSETP", - "cooling_setpoint_schedule": "Courthouse CLGSETP", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "Courthouse", - "space_type": "Courthouse - Parking", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Parking Garage", - "lighting_secondary_space_type": "Garage Area", - "lighting_per_area": 0.2, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Courthouse GENERAL_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": null, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Courthouse BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Garages, Repair, Service Stations", - "ventilation_secondary_space_type": "Enclosed parking garage", - "ventilation_per_area": 1.5, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Courthouse_INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Courthouse HTGSETP", - "cooling_setpoint_schedule": "Courthouse CLGSETP", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "Courthouse", - "space_type": "Courthouse - Plenum", - "lighting_standard": null, - "lighting_primary_space_type": null, - "lighting_secondary_space_type": null, - "lighting_per_area": null, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": null, - "lighting_fraction_radiant": null, - "lighting_fraction_visible": null, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": null, - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": null, - "electric_equipment_fraction_latent": null, - "electric_equipment_fraction_radiant": null, - "electric_equipment_fraction_lost": null, - "electric_equipment_schedule": null, - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": null, - "ventilation_primary_space_type": null, - "ventilation_secondary_space_type": null, - "ventilation_per_area": null, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Courthouse_INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": null, - "cooling_setpoint_schedule": null, - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "Courthouse", - "space_type": "Courthouse - Restrooms", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Restrooms", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Courthouse GENERAL_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.07, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Courthouse BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "Courthouse OFFICE_OCC_SCH", - "occupancy_activity_schedule": "Courthouse ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Public restrooms", - "ventilation_per_area": 0.0, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Courthouse_INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Courthouse HTGSETP", - "cooling_setpoint_schedule": "Courthouse CLGSETP", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "Courthouse BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_169_31" - }, - { - "template": "90.1-2004", - "building_type": "Courthouse", - "space_type": "Courthouse - Security Screening", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.3, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Courthouse GENERAL_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Courthouse BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 10.0, - "occupancy_schedule": "Courthouse OFFICE_OCC_SCH", - "occupancy_activity_schedule": "Courthouse ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Reception Areas", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Courthouse_INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Courthouse HTGSETP", - "cooling_setpoint_schedule": "Courthouse CLGSETP", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "Courthouse", - "space_type": "Courthouse - Service Shaft", - "lighting_standard": null, - "lighting_primary_space_type": null, - "lighting_secondary_space_type": null, - "lighting_per_area": null, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": null, - "lighting_fraction_radiant": null, - "lighting_fraction_visible": null, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": null, - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": null, - "electric_equipment_fraction_latent": null, - "electric_equipment_fraction_radiant": null, - "electric_equipment_fraction_lost": null, - "electric_equipment_schedule": null, - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": null, - "ventilation_primary_space_type": null, - "ventilation_secondary_space_type": null, - "ventilation_per_area": null, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Courthouse_INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": null, - "cooling_setpoint_schedule": null, - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "41_31_169" - }, - { - "template": "90.1-2004", - "building_type": "Courthouse", - "space_type": "Courthouse - Stairs", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Stairs-Active", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.6, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Courthouse GENERAL_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Courthouse BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Courthouse_INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Courthouse HTGSETP", - "cooling_setpoint_schedule": "Courthouse CLGSETP", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "Courthouse", - "space_type": "Courthouse - Storage", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Active Storage", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.8, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Courthouse GENERAL_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Courthouse BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", - "ventilation_secondary_space_type": "Storage rooms", - "ventilation_per_area": 0.15, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Courthouse_INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Courthouse HTGSETP", - "cooling_setpoint_schedule": "Courthouse CLGSETP", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_149_230" - }, - { - "template": "90.1-2004", - "building_type": "Courthouse", - "space_type": "Courthouse - Utility", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Electrical/Mechanical", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Courthouse GENERAL_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.27, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Courthouse BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Courthouse_INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Courthouse HTGSETP", - "cooling_setpoint_schedule": "Courthouse CLGSETP", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "41_31_169" - }, - { - "template": "90.1-2004", - "building_type": "FullServiceRestaurant", - "space_type": "Attic", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Attics", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": null, - "lighting_fraction_radiant": null, - "lighting_fraction_visible": null, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": null, - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": null, - "electric_equipment_fraction_latent": null, - "electric_equipment_fraction_radiant": null, - "electric_equipment_fraction_lost": null, - "electric_equipment_schedule": null, - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": null, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": null, - "ventilation_primary_space_type": null, - "ventilation_secondary_space_type": null, - "ventilation_per_area": null, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": null, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Always On", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": null, - "cooling_setpoint_schedule": null, - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_149_230" - }, - { - "template": "90.1-2004", - "building_type": "FullServiceRestaurant", - "space_type": "Dining", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "For Family Dining", - "lighting_per_area": 2.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "RestaurantSitDown BLDG_LIGHT_KITCHEN_SCH_2004_2007", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 6.032, - "electric_equipment_fraction_latent": 0.25, - "electric_equipment_fraction_radiant": 0.3, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "RestaurantSitDown BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 70.0, - "occupancy_schedule": "RestaurantSitDown BLDG_OCC_SCH", - "occupancy_activity_schedule": "RestaurantSitDown ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Food and Beverage Service", - "ventilation_secondary_space_type": "Dining Rooms", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": null, - "infiltration_per_exterior_wall_area": 0.2016, - "infiltration_air_changes": null, - "infiltration_schedule": "RestaurantSitDown INFIL_HALF_ON_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "RestaurantSitDown HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "RestaurantSitDown CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "31_169_34" - }, - { - "template": "90.1-2004", - "building_type": "FullServiceRestaurant", - "space_type": "Kitchen", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Food Preparation", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.2, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "RestaurantSitDown BLDG_LIGHT_KITCHEN_SCH_2004_2007", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": 205.81, - "gas_equipment_fraction_latent": 0.1, - "gas_equipment_fraction_radiant": 0.2, - "gas_equipment_fraction_lost": 0.7, - "gas_equipment_schedule": "RestaurantSitDown Rest_GAS_EQUIP_SCH", - "electric_equipment_per_area": 37.53, - "electric_equipment_fraction_latent": 0.25, - "electric_equipment_fraction_radiant": 0.3, - "electric_equipment_fraction_lost": 0.2, - "electric_equipment_schedule": "RestaurantSitDown BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.0, - "occupancy_schedule": "RestaurantSitDown BLDG_OCC_SCH", - "occupancy_activity_schedule": "RestaurantSitDown ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Food and Beverage Service", - "ventilation_secondary_space_type": "Kitchens (cooking)", - "ventilation_per_area": 0.47, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": null, - "infiltration_per_exterior_wall_area": 0.2016, - "infiltration_air_changes": null, - "infiltration_schedule": "RestaurantSitDown INFIL_HALF_ON_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "RestaurantSitDown HTGSETP_KITCHEN_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "RestaurantSitDown CLGSETP_KITCHEN_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": 133.0, - "service_water_heating_area": 1501.0, - "service_water_heating_peak_flow_per_area": 0.08860759494, - "service_water_heating_system_type": "Dedicated", - "booster_water_heater_fraction": 0.6, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": 180.0, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "RestaurantSitDown BLDG_SWH_SCH", - "exhaust_per_area": 0.7, - "exhaust_fan_efficiency": 0.338, - "exhaust_fan_power": 694.5023196377475, - "exhaust_fan_pressure_rise": 0.5, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": "RestaurantSitDown Kitchen_Exhaust_SCH", - "exhaust_flow_fraction_schedule": "RestaurantSitDown Kitchen_Exhaust_SCH", - "balanced_exhaust_fraction_schedule": "RestaurantSitDown Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule", - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "78_222_133" - }, - { - "template": "90.1-2004", - "building_type": "HighriseApartment", - "space_type": "Apartment", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "HighriseApartment", - "lighting_secondary_space_type": "Apartment", - "lighting_per_area": 1.07, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": 0.27, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.6, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "ApartmentHighRise LTG_APT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.6196632768, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "ApartmentHighRise EQP_APT_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 2.63, - "occupancy_schedule": "ApartmentHighRise OCC_APT_SCH", - "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", - "is_residential": "Yes", - "ventilation_standard": "ASHRAE 62.1-2004", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Apartment", - "ventilation_per_area": 0.0, - "ventilation_per_person": 0.0, - "ventilation_air_changes": 0.35, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.2016, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH", - "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH", - "service_water_heating_peak_flow_rate": 3.48, - "service_water_heating_area": 950.0, - "service_water_heating_peak_flow_per_area": 0.003663157895, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "ApartmentHighRise APT_DHW_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "78_167_222" - }, - { - "template": "90.1-2004", - "building_type": "HighriseApartment", - "space_type": "Apartment_topfloor_NS", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "HighriseApartment", - "lighting_secondary_space_type": "Apartment", - "lighting_per_area": 1.07, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": 0.27, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.6, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "ApartmentHighRise LTG_APT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.6196632768, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "ApartmentHighRise EQP_APT_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 2.63, - "occupancy_schedule": "ApartmentHighRise OCC_APT_SCH", - "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", - "is_residential": "Yes", - "ventilation_standard": "ASHRAE 62.1-2004", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Apartment", - "ventilation_per_area": 0.0, - "ventilation_per_person": 0.0, - "ventilation_air_changes": 0.35, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0575970048, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH", - "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH", - "service_water_heating_peak_flow_rate": 3.48, - "service_water_heating_area": 950.0, - "service_water_heating_peak_flow_per_area": 0.003663157895, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "ApartmentHighRise APT_DHW_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "78_167_222" - }, - { - "template": "90.1-2004", - "building_type": "HighriseApartment", - "space_type": "Apartment_topfloor_WE", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "HighriseApartment", - "lighting_secondary_space_type": "Apartment", - "lighting_per_area": 1.07, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": 0.27, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.6, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "ApartmentHighRise LTG_APT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.6196632768, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "ApartmentHighRise EQP_APT_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 2.63, - "occupancy_schedule": "ApartmentHighRise OCC_APT_SCH", - "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", - "is_residential": "Yes", - "ventilation_standard": "ASHRAE 62.1-2004", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Apartment", - "ventilation_per_area": 0.0, - "ventilation_per_person": 0.0, - "ventilation_air_changes": 0.35, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0803777592, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH", - "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH", - "service_water_heating_peak_flow_rate": 3.48, - "service_water_heating_area": 950.0, - "service_water_heating_peak_flow_per_area": 0.003663157895, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "ApartmentHighRise APT_DHW_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "78_167_222" - }, - { - "template": "90.1-2004", - "building_type": "HighriseApartment", - "space_type": "Corridor", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "HighriseApartment", - "lighting_secondary_space_type": "Corridor", - "lighting_per_area": 0.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.6, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "ApartmentHighRise LTG_COR_SCH_2004_2007", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "ApartmentMidRise All Off", - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Public restrooms", - "ventilation_per_area": 0.0, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.2016, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": null, - "cooling_setpoint_schedule": null, - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_31" - }, - { - "template": "90.1-2004", - "building_type": "HighriseApartment", - "space_type": "Corridor_topfloor", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "HighriseApartment", - "lighting_secondary_space_type": "Corridor", - "lighting_per_area": 0.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.6, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "ApartmentHighRise LTG_COR_SCH_2004_2007", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "ApartmentMidRise All Off", - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Public restrooms", - "ventilation_per_area": 0.0, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0234460331, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": null, - "cooling_setpoint_schedule": null, - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_31" - }, - { - "template": "90.1-2004", - "building_type": "HighriseApartment", - "space_type": "Office", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "HighriseApartment", - "lighting_secondary_space_type": "Office", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.6, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "ApartmentHighRise LTG_OFF_SCH_2004_2007", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.6196632768, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "ApartmentHighRise EQP_OFF_SCH_2004_2007", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 2.11, - "occupancy_schedule": "ApartmentHighRise OCC_OFF_SCH", - "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Bedrooms", - "ventilation_per_area": 0.1, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.2016, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH", - "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "Hospital", - "space_type": "Basement", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Basement", - "lighting_secondary_space_type": "For Hospital", - "lighting_per_area": 1.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Hospital BLDG_LIGHT_OFFICE_BSMT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.75, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 2.5, - "occupancy_schedule": "Hospital BLDG_OCC_SCH", - "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-2004", - "ventilation_primary_space_type": "Basement", - "ventilation_secondary_space_type": "For Hospital", - "ventilation_per_area": 0.05, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0446, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Hospital INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Hospital HTGSETP_SCH", - "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "Hospital", - "space_type": "Corridor", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Corridor/Transition", - "lighting_secondary_space_type": "For Hospital", - "lighting_per_area": 1.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Hospital BLDG_LIGHT_CORRIDOR_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 1.0, - "occupancy_schedule": "Hospital BLDG_OCC_SCH", - "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Hospital INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Hospital HTGSETP_SCH", - "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_31" - }, - { - "template": "90.1-2004", - "building_type": "Hospital", - "space_type": "Dining", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Hospital BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 10.0, - "occupancy_schedule": "Hospital BLDG_OCC_SCH", - "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Food and Beverage Service", - "ventilation_secondary_space_type": "Dining Rooms", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Hospital INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Hospital HTGSETP_SCH", - "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "31_169_34" - }, - { - "template": "90.1-2004", - "building_type": "Hospital", - "space_type": "ER_Exam", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Emergency", - "lighting_per_area": 2.7, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.5, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 20.0, - "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", - "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "AIA 2001", - "ventilation_primary_space_type": "Surgery and Critical Care", - "ventilation_secondary_space_type": "ER Waiting Room", - "ventilation_per_area": null, - "ventilation_per_person": null, - "ventilation_air_changes": 2.0, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Hospital INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Hospital HTGSETP_SCH", - "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", - "service_water_heating_peak_flow_rate": 1.0, - "service_water_heating_area": 300.0, - "service_water_heating_peak_flow_per_area": 0.003333333333, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_159" - }, - { - "template": "90.1-2004", - "building_type": "Hospital", - "space_type": "ER_NurseStn", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Nurse Station", - "lighting_per_area": 1.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Hospital BLDG_LIGHT_NURSEFLR1_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.36, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 1.333, - "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", - "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Reception Areas", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Hospital INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Hospital HTGSETP_SCH", - "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "31_162_169" - }, - { - "template": "90.1-2004", - "building_type": "Hospital", - "space_type": "ER_Trauma", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Emergency", - "lighting_per_area": 2.7, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 4.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 20.0, - "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", - "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "AIA 2001", - "ventilation_primary_space_type": "Surgery and Critical Care", - "ventilation_secondary_space_type": "ER Waiting Room", - "ventilation_per_area": null, - "ventilation_per_person": null, - "ventilation_air_changes": 2.0, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Hospital INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Hospital HTGSETP_SCH", - "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", - "service_water_heating_peak_flow_rate": 1.0, - "service_water_heating_area": 300.0, - "service_water_heating_peak_flow_per_area": 0.003333333333, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_159" - }, - { - "template": "90.1-2004", - "building_type": "Hospital", - "space_type": "ER_Triage", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Emergency", - "lighting_per_area": 2.7, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 2.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 20.0, - "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", - "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "AIA 2001", - "ventilation_primary_space_type": "Surgery and Critical Care", - "ventilation_secondary_space_type": "ER Waiting Room", - "ventilation_per_area": null, - "ventilation_per_person": null, - "ventilation_air_changes": 2.0, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Hospital INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Hospital HTGSETP_SCH", - "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", - "service_water_heating_peak_flow_rate": 1.0, - "service_water_heating_area": 300.0, - "service_water_heating_peak_flow_per_area": 0.003333333333, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_159" - }, - { - "template": "90.1-2004", - "building_type": "Hospital", - "space_type": "ICU_NurseStn", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Nurse Station", - "lighting_per_area": 1.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 2.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 1.333, - "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", - "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Reception Areas", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Hospital INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Hospital HTGSETP_SCH", - "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "31_162_169" - }, - { - "template": "90.1-2004", - "building_type": "Hospital", - "space_type": "ICU_Open", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Recovery", - "lighting_per_area": 0.8, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 3.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.0, - "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", - "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "AIA 2001", - "ventilation_primary_space_type": "Surgery and Critical Care", - "ventilation_secondary_space_type": "Newborn Intensive Care", - "ventilation_per_area": null, - "ventilation_per_person": null, - "ventilation_air_changes": 2.0, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Hospital INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Hospital HTGSETP_SCH", - "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "78_167_222" - }, - { - "template": "90.1-2004", - "building_type": "Hospital", - "space_type": "ICU_PatRm", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Patient Room", - "lighting_per_area": 0.7, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 3.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.0, - "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", - "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "AIA 2001", - "ventilation_primary_space_type": "Surgery and Critical Care", - "ventilation_secondary_space_type": "Newborn Intensive Care", - "ventilation_per_area": null, - "ventilation_per_person": null, - "ventilation_air_changes": 2.0, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Hospital INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Hospital HTGSETP_SCH", - "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "78_167_222" - }, - { - "template": "90.1-2004", - "building_type": "Hospital", - "space_type": "Kitchen", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Food Preparation", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.2, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Hospital BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": 51.16, - "gas_equipment_fraction_latent": 0.0, - "gas_equipment_fraction_radiant": 0.5, - "gas_equipment_fraction_lost": 0.0, - "gas_equipment_schedule": "Hospital BLDG_EQUIP_SCH", - "electric_equipment_per_area": 7.5, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.0, - "occupancy_schedule": "Hospital BLDG_OCC_SCH", - "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Food and Beverage Service", - "ventilation_secondary_space_type": "Kitchens (cooking)", - "ventilation_per_area": 0.47, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Hospital INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Hospital HTGSETP_SCH", - "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", - "service_water_heating_peak_flow_rate": 150.0, - "service_water_heating_area": 10000.0, - "service_water_heating_peak_flow_per_area": 0.015, - "service_water_heating_system_type": "Dedicated", - "booster_water_heater_fraction": 0.6, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": 180.0, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", - "exhaust_per_area": 0.7, - "exhaust_fan_efficiency": 0.338, - "exhaust_fan_power": 229133.6778, - "exhaust_fan_pressure_rise": 124.5, - "exhaust_fan_maximum_flow_rate": 7200.0, - "exhaust_availability_schedule": "Hospital Kitchen_Exhaust_SCH", - "exhaust_flow_fraction_schedule": "Hospital Kitchen_Exhaust_SCH", - "balanced_exhaust_fraction_schedule": "Hospital Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule", - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "78_222_133" - }, - { - "template": "90.1-2004", - "building_type": "Hospital", - "space_type": "Lab", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Laboratory", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.4, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Hospital BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 4.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.0, - "occupancy_schedule": "Hospital BLDG_OCC_SCH", - "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Education", - "ventilation_secondary_space_type": "Laboratories", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Hospital INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Hospital HTGSETP_SCH", - "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", - "service_water_heating_peak_flow_rate": 2.0, - "service_water_heating_area": 2850.0, - "service_water_heating_peak_flow_per_area": 0.000701754386, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "Hospital BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "204_120_230" - }, - { - "template": "90.1-2004", - "building_type": "Hospital", - "space_type": "Lobby", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.3, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Hospital BLDG_LIGHT_LOBBYFLR1_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.09999999999999999, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 1.333, - "occupancy_schedule": "Hospital BLDG_OCC_SCH", - "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Lobbies", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Hospital INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Hospital HTGSETP_SCH", - "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "31_162_169" - }, - { - "template": "90.1-2004", - "building_type": "Hospital", - "space_type": "NurseStn", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Nurse Station", - "lighting_per_area": 1.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Hospital BLDG_LIGHT_NURSEFLR234_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 2.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 1.333, - "occupancy_schedule": "Hospital BLDG_OCC_SCH", - "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Reception Areas", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Hospital INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Hospital HTGSETP_SCH", - "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "31_162_169" - }, - { - "template": "90.1-2004", - "building_type": "Hospital", - "space_type": "OR", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Operating Room", - "lighting_per_area": 2.2, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 4.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.0, - "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", - "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "AIA 2001", - "ventilation_primary_space_type": "Surgery and Critical Care", - "ventilation_secondary_space_type": "Operating/Surgical Cystoscopic Rooms", - "ventilation_per_area": null, - "ventilation_per_person": null, - "ventilation_air_changes": 3.0, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Hospital INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Hospital HTGSETP_SCH", - "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", - "service_water_heating_peak_flow_rate": 2.0, - "service_water_heating_area": 600.0, - "service_water_heating_peak_flow_per_area": 0.003333333333, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "Hospital BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_159" - }, - { - "template": "90.1-2004", - "building_type": "Hospital", - "space_type": "Office", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Office", - "lighting_secondary_space_type": "For Hospital", - "lighting_per_area": 1.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Hospital BLDG_LIGHT_OFFICE_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 7.0, - "occupancy_schedule": "Hospital BLDG_OCC_SCH", - "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Office Space", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Hospital INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Hospital HTGSETP_SCH", - "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "Hospital", - "space_type": "PatCorridor", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Corridor/Transition", - "lighting_secondary_space_type": "For Hospital", - "lighting_per_area": 1.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Hospital BLDG_LIGHT_CORRIDOR_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 1.0, - "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", - "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Hospital INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Hospital HTGSETP_SCH", - "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_31" - }, - { - "template": "90.1-2004", - "building_type": "Hospital", - "space_type": "PatRoom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Patient Room", - "lighting_per_area": 0.7, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Hospital BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 2.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.0, - "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", - "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", - "is_residential": "Yes", - "ventilation_standard": "AIA 2001", - "ventilation_primary_space_type": "Nursing", - "ventilation_secondary_space_type": "Patient Room", - "ventilation_per_area": null, - "ventilation_per_person": null, - "ventilation_air_changes": 2.0, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Hospital INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Hospital HTGSETP_SCH", - "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", - "service_water_heating_peak_flow_rate": 1.0, - "service_water_heating_area": 280.0, - "service_water_heating_peak_flow_per_area": 0.003571428571, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "78_167_222" - }, - { - "template": "90.1-2004", - "building_type": "Hospital", - "space_type": "PhysTherapy", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Physical Therapy", - "lighting_per_area": 0.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Hospital BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.5, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.0, - "occupancy_schedule": "Hospital BLDG_OCC_SCH", - "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", - "ventilation_secondary_space_type": "Physical therapy", - "ventilation_per_area": 0.47, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Hospital INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Hospital HTGSETP_SCH", - "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", - "service_water_heating_peak_flow_rate": 1.0, - "service_water_heating_area": 5280.0, - "service_water_heating_peak_flow_per_area": 0.0001893939394, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "Hospital BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "154_230_120" - }, - { - "template": "90.1-2004", - "building_type": "Hospital", - "space_type": "Radiology", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Radiology", - "lighting_per_area": 0.4, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Hospital BLDG_LIGHT_RADIOLOGY_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 10.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.0, - "occupancy_schedule": "Hospital BLDG_OCC_SCH", - "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", - "ventilation_secondary_space_type": "Medical procedure", - "ventilation_per_area": 0.47, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Hospital INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Hospital HTGSETP_SCH", - "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", - "service_water_heating_peak_flow_rate": 1.0, - "service_water_heating_area": 5250.0, - "service_water_heating_peak_flow_per_area": 0.0001904761905, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "136_78_222" - }, - { - "template": "90.1-2004", - "building_type": "Laboratory", - "space_type": "Equipment corridor", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Corridor/Transition", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Lab_LIGHT_CORRIDOR_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 15.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Lab_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "Lab_OCC_SCH", - "occupancy_activity_schedule": "Lab_OCC_Activity", - "is_residential": null, - "ventilation_standard": "ASHRAE TC9.10", - "ventilation_primary_space_type": "Laboratory", - "ventilation_secondary_space_type": "Equipment corridor", - "ventilation_per_area": 1.0, - "ventilation_per_person": 10.0, - "ventilation_air_changes": 6.0, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.2016, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Lab_INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Lab_HTGSETP_SCH", - "cooling_setpoint_schedule": "Lab_CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null - }, - { - "template": "90.1-2004", - "building_type": "Laboratory", - "space_type": "Lab with fume hood", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Laboratory", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.4, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Lab_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 4.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Lab_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.0, - "occupancy_schedule": "Lab_OCC_SCH", - "occupancy_activity_schedule": "Lab_OCC_Activity", - "is_residential": null, - "ventilation_standard": "ASHRAE TC9.10", - "ventilation_primary_space_type": "Laboratory", - "ventilation_secondary_space_type": "Lab with fume hood", - "ventilation_per_area": 0.18, - "ventilation_per_person": 10.0, - "ventilation_air_changes": 15.0, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.2016, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Lab_INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Lab_HTGSETP_SCH", - "cooling_setpoint_schedule": "Lab_CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": 0.000701754, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "Lab_BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null - }, - { - "template": "90.1-2004", - "building_type": "Laboratory", - "space_type": "Office", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Office-Open Plan", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.96, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH_2004", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.25, - "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Office Space", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": 0.0, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.2016, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_PACU_VAV_bot", - "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": 0.000950996, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "OfficeMedium BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null - }, - { - "template": "90.1-2004", - "building_type": "Laboratory", - "space_type": "Open lab", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Laboratory", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.4, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Lab_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 4.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Lab_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.0, - "occupancy_schedule": "Lab_OCC_SCH", - "occupancy_activity_schedule": "Lab_OCC_Activity", - "is_residential": null, - "ventilation_standard": "ASHRAE TC9.10", - "ventilation_primary_space_type": "Laboratory", - "ventilation_secondary_space_type": "Open lab", - "ventilation_per_area": 1.0, - "ventilation_per_person": 10.0, - "ventilation_air_changes": 6.0, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.2016, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Lab_INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Lab_HTGSETP_SCH", - "cooling_setpoint_schedule": "Lab_CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": 0.000701754, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "Lab_BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null - }, - { - "template": "90.1-2004", - "building_type": "LargeDataCenterHighITE", - "space_type": "StandaloneDataCenter", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "OfficeLarge", - "lighting_secondary_space_type": "Data Center", - "lighting_per_area": 1.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "DataCenter Lighting_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 500.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.1, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "DataCenter Equipment_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": null, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-2007", - "ventilation_primary_space_type": "Miscellaneous Spaces", - "ventilation_secondary_space_type": "Computer (not printing)", - "ventilation_per_area": 0.06, - "ventilation_per_person": 5.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": null, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": null, - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "DataCenter HTGSETP_SCH", - "cooling_setpoint_schedule": "DataCenter CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_31" - }, - { - "template": "90.1-2004", - "building_type": "LargeDataCenterLowITE", - "space_type": "StandaloneDataCenter", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "OfficeLarge", - "lighting_secondary_space_type": "Data Center", - "lighting_per_area": 1.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "DataCenter Lighting_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 100.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.1, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "DataCenter Equipment_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": null, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-2007", - "ventilation_primary_space_type": "Miscellaneous Spaces", - "ventilation_secondary_space_type": "Computer (not printing)", - "ventilation_per_area": 0.06, - "ventilation_per_person": 5.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": null, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": null, - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "DataCenter HTGSETP_SCH", - "cooling_setpoint_schedule": "DataCenter CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_31" - }, - { - "template": "90.1-2004", - "building_type": "LargeHotel", - "space_type": "Banquet", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "For Hotel", - "lighting_per_area": 1.3, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 6.301, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelLarge Kitchen_Elec_Equip_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 67.0, - "occupancy_schedule": "HotelLarge MeetingRoom_Occ_Sch", - "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Conference rooms", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelLarge INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", - "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_196_120" - }, - { - "template": "90.1-2004", - "building_type": "LargeHotel", - "space_type": "Basement", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Basement", - "lighting_secondary_space_type": "For Hotel", - "lighting_per_area": 1.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelLarge BLDG_LIGHT_OFFICE_BSMT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.5, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.0, - "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-2007", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Multipurpose assembly", - "ventilation_per_area": 0.06, - "ventilation_per_person": 5.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", - "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_149_230" - }, - { - "template": "90.1-2004", - "building_type": "LargeHotel", - "space_type": "Cafe", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "For Hotel", - "lighting_per_area": 1.3, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.5, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 67.0, - "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Food and Beverage Service", - "ventilation_secondary_space_type": "Cafeteria, fast food", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelLarge INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", - "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "31_169_34" - }, - { - "template": "90.1-2004", - "building_type": "LargeHotel", - "space_type": "Corridor", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Corridor/Transition", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelLarge BLDG_LIGHT_CORRIDOR_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 1.0, - "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelLarge INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", - "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_31" - }, - { - "template": "90.1-2004", - "building_type": "LargeHotel", - "space_type": "Corridor2", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Corridor/Transition", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelLarge BLDG_LIGHT_CORRIDOR_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-2007", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.112, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", - "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_31" - }, - { - "template": "90.1-2004", - "building_type": "LargeHotel", - "space_type": "GuestRoom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hotel/Motel", - "lighting_secondary_space_type": "Guest Rooms", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.627, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 3.57, - "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch", - "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", - "is_residential": "Yes", - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Dormitory sleeping areas", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelLarge INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelLarge Base_OccGuestRoom_HtgSP_Sch", - "cooling_setpoint_schedule": "HotelLarge Base_OccGuestRoom_ClgSP_Sch", - "service_water_heating_peak_flow_rate": 1.25, - "service_water_heating_area": 420.0, - "service_water_heating_peak_flow_per_area": 0.002976190476, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "78_167_222" - }, - { - "template": "90.1-2004", - "building_type": "LargeHotel", - "space_type": "GuestRoom2", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hotel/Motel", - "lighting_secondary_space_type": "Guest Rooms", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.977, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.68, - "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch", - "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", - "is_residential": "Yes", - "ventilation_standard": "ASHRAE 62.1-2007", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Bedroom/living Room", - "ventilation_per_area": 0.06, - "ventilation_per_person": 5.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.112, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelLarge Base_OccGuestRoom_HtgSP_Sch", - "cooling_setpoint_schedule": "HotelLarge Base_OccGuestRoom_ClgSP_Sch", - "service_water_heating_peak_flow_rate": 1.25, - "service_water_heating_area": 264.0, - "service_water_heating_peak_flow_per_area": 0.004734848485, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "78_167_222" - }, - { - "template": "90.1-2004", - "building_type": "LargeHotel", - "space_type": "GuestRoom3", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hotel/Motel", - "lighting_secondary_space_type": "Guest Rooms", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.627, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 3.57, - "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch", - "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", - "is_residential": "Yes", - "ventilation_standard": "ASHRAE 62.1-2007", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Bedroom/living Room", - "ventilation_per_area": 0.06, - "ventilation_per_person": 5.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0566608, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelLarge Base_OccGuestRoom_HtgSP_Sch", - "cooling_setpoint_schedule": "HotelLarge Base_OccGuestRoom_ClgSP_Sch", - "service_water_heating_peak_flow_rate": 1.25, - "service_water_heating_area": 420.0, - "service_water_heating_peak_flow_per_area": 0.002976190476, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "78_167_222" - }, - { - "template": "90.1-2004", - "building_type": "LargeHotel", - "space_type": "GuestRoom4", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hotel/Motel", - "lighting_secondary_space_type": "Guest Rooms", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.977, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.68, - "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch", - "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", - "is_residential": "Yes", - "ventilation_standard": "ASHRAE 62.1-2007", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Bedroom/living Room", - "ventilation_per_area": 0.06, - "ventilation_per_person": 5.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.050904, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelLarge Base_OccGuestRoom_HtgSP_Sch", - "cooling_setpoint_schedule": "HotelLarge Base_OccGuestRoom_ClgSP_Sch", - "service_water_heating_peak_flow_rate": 1.25, - "service_water_heating_area": 264.0, - "service_water_heating_peak_flow_per_area": 0.004734848485, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "78_167_222" - }, - { - "template": "90.1-2004", - "building_type": "LargeHotel", - "space_type": "GuestRoom5", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hotel/Motel", - "lighting_secondary_space_type": "Guest Rooms", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.759, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 4.325, - "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch", - "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", - "is_residential": "Yes", - "ventilation_standard": "ASHRAE 62.1-2007", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Bedroom/living Room", - "ventilation_per_area": 0.06, - "ventilation_per_person": 5.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.112, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelLarge Base_OccGuestRoom_HtgSP_Sch", - "cooling_setpoint_schedule": "HotelLarge Base_OccGuestRoom_ClgSP_Sch", - "service_water_heating_peak_flow_rate": 1.25, - "service_water_heating_area": 346.8, - "service_water_heating_peak_flow_per_area": 0.00360438293, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "78_167_222" - }, - { - "template": "90.1-2004", - "building_type": "LargeHotel", - "space_type": "GuestRoom6", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hotel/Motel", - "lighting_secondary_space_type": "Guest Rooms", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.62, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 3.53, - "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch", - "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", - "is_residential": "Yes", - "ventilation_standard": "ASHRAE 62.1-2007", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Bedroom/living Room", - "ventilation_per_area": 0.06, - "ventilation_per_person": 5.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.112, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelLarge Base_OccGuestRoom_HtgSP_Sch", - "cooling_setpoint_schedule": "HotelLarge Base_OccGuestRoom_ClgSP_Sch", - "service_water_heating_peak_flow_rate": 1.25, - "service_water_heating_area": 425.0, - "service_water_heating_peak_flow_per_area": 0.002941176471, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "78_167_222" - }, - { - "template": "90.1-2004", - "building_type": "LargeHotel", - "space_type": "GuestRoom7", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hotel/Motel", - "lighting_secondary_space_type": "Guest Rooms", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.453, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 2.58, - "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch", - "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", - "is_residential": "Yes", - "ventilation_standard": "ASHRAE 62.1-2007", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Bedroom/living Room", - "ventilation_per_area": 0.06, - "ventilation_per_person": 5.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.112, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelLarge Base_OccGuestRoom_HtgSP_Sch", - "cooling_setpoint_schedule": "HotelLarge Base_OccGuestRoom_ClgSP_Sch", - "service_water_heating_peak_flow_rate": 1.25, - "service_water_heating_area": 581.4, - "service_water_heating_peak_flow_per_area": 0.0021499828, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "78_167_222" - }, - { - "template": "90.1-2004", - "building_type": "LargeHotel", - "space_type": "GuestRoom8", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hotel/Motel", - "lighting_secondary_space_type": "Guest Rooms", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.977, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.68, - "occupancy_schedule": "Always Off", - "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", - "is_residential": "Yes", - "ventilation_standard": "ASHRAE 62.1-2007", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Bedroom/living Room", - "ventilation_per_area": 0.06, - "ventilation_per_person": 5.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.112, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelLarge VAC_OccGuestRoom_HtgSP_Sch", - "cooling_setpoint_schedule": "HotelLarge VAC_OccGuestRoom_ClgSP_Sch", - "service_water_heating_peak_flow_rate": 1.25, - "service_water_heating_area": 264.0, - "service_water_heating_peak_flow_per_area": 0.004734848485, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null - }, - { - "template": "90.1-2004", - "building_type": "LargeHotel", - "space_type": "Kitchen", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Food Preparation", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.2, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": 767.0, - "gas_equipment_fraction_latent": 0.1, - "gas_equipment_fraction_radiant": 0.2, - "gas_equipment_fraction_lost": 0.7, - "gas_equipment_schedule": "HotelLarge Kitchen_Gas_Equip_SCH", - "electric_equipment_per_area": 47.2, - "electric_equipment_fraction_latent": 0.2, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.1, - "electric_equipment_schedule": "HotelLarge Kitchen_Elec_Equip_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.0, - "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Food and Beverage Service", - "ventilation_secondary_space_type": "Kitchens (cooking)", - "ventilation_per_area": 0.47, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelLarge INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", - "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", - "service_water_heating_peak_flow_rate": 133.0, - "service_water_heating_area": 1112.0, - "service_water_heating_peak_flow_per_area": 0.1196043165, - "service_water_heating_system_type": "Dedicated", - "booster_water_heater_fraction": 0.6, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": 180.0, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "HotelLarge BLDG_SWH_SCH", - "exhaust_per_area": 0.7, - "exhaust_fan_efficiency": 0.16, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": 125.0, - "exhaust_fan_maximum_flow_rate": 4000.0, - "exhaust_availability_schedule": "HotelLarge Kitchen_Exhaust_SCH", - "exhaust_flow_fraction_schedule": "HotelLarge Kitchen_Exhaust_SCH", - "balanced_exhaust_fraction_schedule": "HotelLarge Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule", - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "78_222_133" - }, - { - "template": "90.1-2004", - "building_type": "LargeHotel", - "space_type": "Laundry", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Laundry-Washing", - "lighting_per_area": 0.6, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": 170.0, - "gas_equipment_fraction_latent": 0.0, - "gas_equipment_fraction_radiant": 0.5, - "gas_equipment_fraction_lost": 0.0, - "gas_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", - "electric_equipment_per_area": 5.73, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 4.0, - "occupancy_schedule": "HotelLarge LaundryRoom_Occ_Sch", - "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Dry Cleaners, Laundries", - "ventilation_secondary_space_type": "Commercial Laundry", - "ventilation_per_area": 0.0, - "ventilation_per_person": 25.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelLarge INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", - "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", - "service_water_heating_peak_flow_rate": 156.6, - "service_water_heating_area": 840.0, - "service_water_heating_peak_flow_per_area": 0.1864285714, - "service_water_heating_system_type": "Dedicated", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "HotelLarge LaundryRoom_SWH_Sch_Post2004", - "exhaust_per_area": null, - "exhaust_fan_efficiency": 0.16, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": 125.0, - "exhaust_fan_maximum_flow_rate": 500.0, - "exhaust_availability_schedule": "HotelLarge Hours_of_operation", - "exhaust_flow_fraction_schedule": "HotelLarge Hours_of_operation", - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_149_230" - }, - { - "template": "90.1-2004", - "building_type": "LargeHotel", - "space_type": "Lobby", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "For Hotel", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.7500000000000001, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 30.0, - "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Lobbies", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelLarge INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", - "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "LargeHotel", - "space_type": "Mechanical", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Electrical/Mechanical", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.5, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelLarge INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", - "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "41_31_169" - }, - { - "template": "90.1-2004", - "building_type": "LargeHotel", - "space_type": "Retail", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Building Area", - "lighting_per_area": 1.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 15.0, - "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", - "ventilation_secondary_space_type": "Basement and street", - "ventilation_per_area": 0.3, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelLarge INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", - "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "171_222_78" - }, - { - "template": "90.1-2004", - "building_type": "LargeHotel", - "space_type": "Retail2", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Building Area", - "lighting_per_area": 1.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 15.0, - "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", - "ventilation_secondary_space_type": "Basement and street", - "ventilation_per_area": 0.3, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.112, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", - "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "171_222_78" - }, - { - "template": "90.1-2004", - "building_type": "LargeHotel", - "space_type": "Storage", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Active Storage", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.8, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelLarge BLDG_LIGHT_STORAGE_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.24999999999999997, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 2.0, - "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", - "ventilation_secondary_space_type": "Shipping and receiving", - "ventilation_per_area": 0.15, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelLarge INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", - "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_149_230" - }, - { - "template": "90.1-2004", - "building_type": "LargeOffice", - "space_type": "Retail", - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.3, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "notes": null, - "occupancy_per_area": 15.0, - "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH", - "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Specialty Shops", - "ventilation_secondary_space_type": "Clothiers, furniture", - "ventilation_per_area": 0.3, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "lighting_primary_space_type": "Retail (not including accent lighting)", - "lighting_secondary_space_type": "Sales Area", - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null - }, - { - "template": "90.1-2004", - "building_type": "MidriseApartment", - "space_type": "Apartment", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "MidriseApartment", - "lighting_secondary_space_type": "Apartment", - "lighting_per_area": 1.07, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": 0.27, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.6, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "ApartmentMidRise LTG_APT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.6196632768, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 2.63, - "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH", - "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", - "is_residential": "Yes", - "ventilation_standard": "ASHRAE 62.1-2004", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Apartment", - "ventilation_per_area": 0.0, - "ventilation_per_person": 0.0, - "ventilation_air_changes": 0.35, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.2016, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "ApartmentMidRise INF_APT_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH", - "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH", - "service_water_heating_peak_flow_rate": 3.48, - "service_water_heating_area": 950.0, - "service_water_heating_peak_flow_per_area": 0.003663157895, - "service_water_heating_system_type": "One Per Unit", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "78_167_222" - }, - { - "template": "90.1-2004", - "building_type": "MidriseApartment", - "space_type": "Apartment_topfloor_NS", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "MidriseApartment", - "lighting_secondary_space_type": "Apartment", - "lighting_per_area": 1.07, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": 0.27, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.6, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "ApartmentMidRise LTG_APT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.6196632768, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 2.63, - "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH", - "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", - "is_residential": "Yes", - "ventilation_standard": "ASHRAE 62.1-2004", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Apartment", - "ventilation_per_area": 0.0, - "ventilation_per_person": 0.0, - "ventilation_air_changes": 0.35, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0575970048, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "ApartmentMidRise INF_APT_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH", - "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH", - "service_water_heating_peak_flow_rate": 3.48, - "service_water_heating_area": 950.0, - "service_water_heating_peak_flow_per_area": 0.003663157895, - "service_water_heating_system_type": "One Per Unit", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "78_167_222" - }, - { - "template": "90.1-2004", - "building_type": "MidriseApartment", - "space_type": "Apartment_topfloor_WE", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "MidriseApartment", - "lighting_secondary_space_type": "Apartment", - "lighting_per_area": 1.07, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": 0.27, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.6, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "ApartmentMidRise LTG_APT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.6196632768, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 2.63, - "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH", - "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", - "is_residential": "Yes", - "ventilation_standard": "ASHRAE 62.1-2004", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Apartment", - "ventilation_per_area": 0.0, - "ventilation_per_person": 0.0, - "ventilation_air_changes": 0.35, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0803777592, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "ApartmentMidRise INF_APT_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH", - "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH", - "service_water_heating_peak_flow_rate": 3.48, - "service_water_heating_area": 950.0, - "service_water_heating_peak_flow_per_area": 0.003663157895, - "service_water_heating_system_type": "One Per Unit", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "78_167_222" - }, - { - "template": "90.1-2004", - "building_type": "MidriseApartment", - "space_type": "Corridor", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "MidriseApartment", - "lighting_secondary_space_type": "Corridor", - "lighting_per_area": 0.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.6, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "ApartmentMidRise LTG_COR_SCH_2004_2007", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "ApartmentMidRise All Off", - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Public restrooms", - "ventilation_per_area": 0.0, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.2016, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "ApartmentMidRise INF_COR_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH", - "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_31" - }, - { - "template": "90.1-2004", - "building_type": "MidriseApartment", - "space_type": "Corridor_topfloor", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "MidriseApartment", - "lighting_secondary_space_type": "Corridor", - "lighting_per_area": 0.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.6, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "ApartmentMidRise LTG_COR_SCH_2004_2007", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "ApartmentMidRise All Off", - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Public restrooms", - "ventilation_per_area": 0.0, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0234460331, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "ApartmentMidRise INF_COR_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH", - "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_31" - }, - { - "template": "90.1-2004", - "building_type": "MidriseApartment", - "space_type": "Office", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "MidriseApartment", - "lighting_secondary_space_type": "Office", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.6, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "ApartmentMidRise LTG_OFF_SCH_2004_2007", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.6196632768, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "ApartmentMidRise EQP_OFF_SCH_2004_2007", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 2.11, - "occupancy_schedule": "ApartmentMidRise OCC_OFF_SCH", - "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Bedrooms", - "ventilation_per_area": 0.1, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.2016, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "ApartmentMidRise INF_OFF_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_OFF_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_OFF_SCH_No_Setback", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "Attic", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Attics", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": null, - "lighting_fraction_radiant": null, - "lighting_fraction_visible": null, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": null, - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": null, - "electric_equipment_fraction_latent": null, - "electric_equipment_fraction_radiant": null, - "electric_equipment_fraction_lost": null, - "electric_equipment_schedule": null, - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": null, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": null, - "ventilation_primary_space_type": null, - "ventilation_secondary_space_type": null, - "ventilation_per_area": null, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": null, - "cooling_setpoint_schedule": null, - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_149_230" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "BreakRoom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Lounge/Recreation", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.2, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.4, - "lighting_fraction_radiant": 0.4, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 5.58, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 50.0, - "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Reception Areas", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "Classroom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Classroom/Lecture/Training", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.4, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.4, - "lighting_fraction_radiant": 0.4, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.929, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 35.0, - "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Education", - "ventilation_secondary_space_type": "Classroom", - "ventilation_per_area": 0.0, - "ventilation_per_person": 16.95, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_196_120" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "ClosedOffice", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Office-Enclosed", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.4, - "lighting_fraction_radiant": 0.4, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": "na", - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.87, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 4.75, - "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Office Space", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "Conference", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Conference/Meeting/Multipurpose", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.3, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.4, - "lighting_fraction_radiant": 0.4, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 50.0, - "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Conference rooms", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_196_120" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "Corridor", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Corridor/Transition", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.4, - "lighting_fraction_radiant": 0.4, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.29, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 1.0, - "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_31" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "Dining", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.4, - "lighting_fraction_radiant": 0.4, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 10.0, - "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Reception areas", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "Elec/MechRoom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Electrical/Mechanical", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.4, - "lighting_fraction_radiant": 0.4, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.27, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Office Space", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "41_31_169" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "Elevator Lobby", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.3, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.07, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 10.0, - "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Reception Areas", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "Elevator Machine Room", - "lighting_standard": null, - "lighting_primary_space_type": null, - "lighting_secondary_space_type": null, - "lighting_per_area": null, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": null, - "lighting_fraction_radiant": null, - "lighting_fraction_visible": null, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": null, - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": null, - "electric_equipment_fraction_latent": null, - "electric_equipment_fraction_radiant": null, - "electric_equipment_fraction_lost": null, - "electric_equipment_schedule": null, - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": null, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": null, - "ventilation_primary_space_type": null, - "ventilation_secondary_space_type": null, - "ventilation_per_area": null, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "TallBuilding Elevator Machine Room HTGSETP_SCH", - "cooling_setpoint_schedule": "TallBuilding Elevator Machine Room CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "Elevator Shaft", - "lighting_standard": null, - "lighting_primary_space_type": null, - "lighting_secondary_space_type": null, - "lighting_per_area": null, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": null, - "lighting_fraction_radiant": null, - "lighting_fraction_visible": null, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": null, - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": null, - "electric_equipment_fraction_latent": null, - "electric_equipment_fraction_radiant": null, - "electric_equipment_fraction_lost": null, - "electric_equipment_schedule": null, - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": null, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": null, - "ventilation_primary_space_type": null, - "ventilation_secondary_space_type": null, - "ventilation_per_area": null, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": null, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": null, - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": null, - "cooling_setpoint_schedule": null, - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "IT_Room", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Office-Enclosed", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.4, - "lighting_fraction_radiant": 0.4, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 2.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.0, - "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "41_31_169" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "Lobby", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.3, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.4, - "lighting_fraction_radiant": 0.4, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.27, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 10.0, - "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Reception Areas", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "Main Electrical", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Electrical/Mechanical", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.4, - "lighting_fraction_radiant": 0.4, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.27, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Office Space", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "Main Mechanical", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Electrical/Mechanical", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.4, - "lighting_fraction_radiant": 0.4, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.5, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Office Space", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "MediumOffice - Breakroom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Lounge/Recreation", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.2, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 5.58, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH_2004", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 50.0, - "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Reception Areas", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_PACU_VAV_bot", - "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "MediumOffice - Classroom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Classroom/Lecture/Training", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.4, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.929, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH_2004", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 35.0, - "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Education", - "ventilation_secondary_space_type": "Classroom", - "ventilation_per_area": 0.0, - "ventilation_per_person": 16.95, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_PACU_VAV_bot", - "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_196_120" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "MediumOffice - ClosedOffice", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Office-Enclosed", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": "na", - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.87, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH_2004", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 4.75, - "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Office Space", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_PACU_VAV_bot", - "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "MediumOffice - Conference", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Conference/Meeting/Multipurpose", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.3, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH_2004", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 50.0, - "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Conference rooms", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_PACU_VAV_bot", - "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_196_120" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "MediumOffice - Corridor", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Corridor/Transition", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.29, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH_2004", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_PACU_VAV_bot", - "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_31" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "MediumOffice - Dining", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH_2004", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 10.0, - "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Reception areas", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_PACU_VAV_bot", - "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "MediumOffice - Elec/MechRoom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Electrical/Mechanical", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.27, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH_2004", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", - "ventilation_secondary_space_type": "Storage rooms", - "ventilation_per_area": 0.15, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_PACU_VAV_bot", - "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": 51.0, - "service_water_heating_area": 1608.45, - "service_water_heating_peak_flow_per_area": 0.03170754453, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "OfficeMedium BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "41_31_169" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "MediumOffice - Lobby", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.3, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.27, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH_2004", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 10.0, - "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Reception Areas", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_PACU_VAV_bot", - "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "MediumOffice - OpenOffice", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Office-Open Plan", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.96, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH_2004", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.25, - "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Office Space", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_PACU_VAV_bot", - "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "MediumOffice - Restroom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Restrooms", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.27, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH_2004", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_PACU_VAV_bot", - "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_169_31" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "MediumOffice - Stair", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Stairs-Active", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.6, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH_2004", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_PACU_VAV_bot", - "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "MediumOffice - Storage", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Active Storage", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.8, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH_2004", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", - "ventilation_secondary_space_type": "Storage rooms", - "ventilation_per_area": 0.15, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_PACU_VAV_bot", - "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_149_230" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "OfficeLarge Data Center", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "OfficeLarge", - "lighting_secondary_space_type": "Data Center", - "lighting_per_area": 1.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 20.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "DataCenter_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": null, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": null, - "ventilation_primary_space_type": null, - "ventilation_secondary_space_type": null, - "ventilation_per_area": null, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": null, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": null, - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeLarge HTGSETP_DC_SCH", - "cooling_setpoint_schedule": "OfficeLarge CLGSETP_DC_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "OfficeLarge Main Data Center", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "OfficeLarge", - "lighting_secondary_space_type": "Data Center", - "lighting_per_area": 1.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 45.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "DataCenter_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": null, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": null, - "ventilation_primary_space_type": null, - "ventilation_secondary_space_type": null, - "ventilation_per_area": null, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": null, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": null, - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeLarge HTGSETP_DC_SCH", - "cooling_setpoint_schedule": "OfficeLarge CLGSETP_DC_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "OpenOffice", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Office-Open Plan", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.4, - "lighting_fraction_radiant": 0.4, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.96, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.25, - "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Office Space", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "PrintRoom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Office-Enclosed", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.4, - "lighting_fraction_radiant": 0.4, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 5.4, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 10.0, - "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "41_31_169" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "Restroom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Restrooms", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.4, - "lighting_fraction_radiant": 0.4, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": "This is only used in Tall Building office stories, value for one story. For individual large office building type, SWH is added via hardcoding to certain zones and Main Service Water Peak FlowRate in \"prototype_input\".", - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.27, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 10.0, - "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)", - "ventilation_per_area": 0.96, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": 34.8, - "service_water_heating_area": 170.0, - "service_water_heating_peak_flow_per_area": 0.2047058824, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "OfficeLarge BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_169_31" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "SmallOffice - Attic", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Attics", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": null, - "lighting_fraction_radiant": null, - "lighting_fraction_visible": null, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": null, - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": null, - "electric_equipment_fraction_latent": null, - "electric_equipment_fraction_radiant": null, - "electric_equipment_fraction_lost": null, - "electric_equipment_schedule": null, - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": null, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": null, - "ventilation_primary_space_type": null, - "ventilation_secondary_space_type": null, - "ventilation_per_area": null, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeSmall INFIL_QUARTER_ON_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": null, - "cooling_setpoint_schedule": null, - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_149_230" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "SmallOffice - Breakroom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Lounge/Recreation", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.2, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.4, - "lighting_fraction_radiant": 0.4, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeSmall BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 5.58, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeSmall BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 50.0, - "occupancy_schedule": "OfficeSmall BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeSmall ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Reception Areas", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeSmall INFIL_QUARTER_ON_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeSmall HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "OfficeSmall CLGSETP_SCH_NO_OPTIMUM", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "SmallOffice - Classroom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Classroom/Lecture/Training", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.4, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.4, - "lighting_fraction_radiant": 0.4, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeSmall BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.929, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeSmall BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 35.0, - "occupancy_schedule": "OfficeSmall BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeSmall ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Education", - "ventilation_secondary_space_type": "Classroom", - "ventilation_per_area": 0.0, - "ventilation_per_person": 16.95, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeSmall INFIL_QUARTER_ON_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeSmall HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "OfficeSmall CLGSETP_SCH_NO_OPTIMUM", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_196_120" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "SmallOffice - ClosedOffice", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Office-Enclosed", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.4, - "lighting_fraction_radiant": 0.4, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeSmall BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": "na", - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.87, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeSmall BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 4.75, - "occupancy_schedule": "OfficeSmall BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeSmall ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Office Space", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeSmall INFIL_QUARTER_ON_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeSmall HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "OfficeSmall CLGSETP_SCH_NO_OPTIMUM", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "SmallOffice - Conference", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Conference/Meeting/Multipurpose", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.3, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.4, - "lighting_fraction_radiant": 0.4, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeSmall BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeSmall BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 50.0, - "occupancy_schedule": "OfficeSmall BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeSmall ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Conference rooms", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeSmall INFIL_QUARTER_ON_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeSmall HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "OfficeSmall CLGSETP_SCH_NO_OPTIMUM", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_196_120" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "SmallOffice - Corridor", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Corridor/Transition", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.4, - "lighting_fraction_radiant": 0.4, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeSmall BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.29, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeSmall BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "OfficeSmall BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeSmall ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeSmall INFIL_QUARTER_ON_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeSmall HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "OfficeSmall CLGSETP_SCH_NO_OPTIMUM", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_31" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "SmallOffice - Dining", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.4, - "lighting_fraction_radiant": 0.4, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeSmall BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeSmall BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 10.0, - "occupancy_schedule": "OfficeSmall BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeSmall ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Reception areas", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeSmall INFIL_QUARTER_ON_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeSmall HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "OfficeSmall CLGSETP_SCH_NO_OPTIMUM", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "SmallOffice - Elec/MechRoom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Electrical/Mechanical", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.4, - "lighting_fraction_radiant": 0.4, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeSmall BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.27, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeSmall BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", - "ventilation_secondary_space_type": "Storage rooms", - "ventilation_per_area": 0.15, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeSmall INFIL_QUARTER_ON_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeSmall HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "OfficeSmall CLGSETP_SCH_NO_OPTIMUM", - "service_water_heating_peak_flow_rate": 3.0, - "service_water_heating_area": 5502.0, - "service_water_heating_peak_flow_per_area": 0.0005452562704, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "OfficeSmall BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "41_31_169" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "SmallOffice - Lobby", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.3, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.4, - "lighting_fraction_radiant": 0.4, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeSmall BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.27, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeSmall BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 10.0, - "occupancy_schedule": "OfficeSmall BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeSmall ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Reception Areas", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeSmall INFIL_QUARTER_ON_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeSmall HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "OfficeSmall CLGSETP_SCH_NO_OPTIMUM", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "SmallOffice - OpenOffice", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Office-Open Plan", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.4, - "lighting_fraction_radiant": 0.4, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeSmall BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.96, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeSmall BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.25, - "occupancy_schedule": "OfficeSmall BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeSmall ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Office Space", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeSmall INFIL_QUARTER_ON_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeSmall HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "OfficeSmall CLGSETP_SCH_NO_OPTIMUM", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "SmallOffice - Restroom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Restrooms", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.4, - "lighting_fraction_radiant": 0.4, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeSmall BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.27, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeSmall BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "OfficeSmall BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeSmall ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeSmall INFIL_QUARTER_ON_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeSmall HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "OfficeSmall CLGSETP_SCH_NO_OPTIMUM", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_169_31" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "SmallOffice - Stair", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Stairs-Active", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.6, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.4, - "lighting_fraction_radiant": 0.4, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeSmall BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeSmall BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeSmall INFIL_QUARTER_ON_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeSmall HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "OfficeSmall CLGSETP_SCH_NO_OPTIMUM", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "SmallOffice - Storage", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Active Storage", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.8, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.4, - "lighting_fraction_radiant": 0.4, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeSmall BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeSmall BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", - "ventilation_secondary_space_type": "Storage rooms", - "ventilation_per_area": 0.15, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeSmall INFIL_QUARTER_ON_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeSmall HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "OfficeSmall CLGSETP_SCH_NO_OPTIMUM", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_149_230" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "Stair", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Stairs-Active", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.6, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.4, - "lighting_fraction_radiant": 0.4, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "Storage", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Active Storage", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.8, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.4, - "lighting_fraction_radiant": 0.4, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_149_230" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "Vending", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Corridor/Transition", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.4, - "lighting_fraction_radiant": 0.4, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 3.85, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 1.0, - "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "WholeBuilding - Lg Office", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Whole Building", - "lighting_secondary_space_type": "Office", - "lighting_per_area": 1.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.74973447, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.0, - "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeLarge ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Office Buildings", - "ventilation_secondary_space_type": "Whole Building", - "ventilation_per_area": 0.1, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.201599, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": 27.7, - "service_water_heating_area": 53628.0, - "service_water_heating_peak_flow_per_area": 0.0005165212203, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "OfficeLarge BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "WholeBuilding - Lg Office-basement", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Whole Building", - "lighting_secondary_space_type": "Office", - "lighting_per_area": 1.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.45, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Always On", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.0, - "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeLarge ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Office Buildings", - "ventilation_secondary_space_type": "Whole Building", - "ventilation_per_area": 0.1, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.201599, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": 27.7, - "service_water_heating_area": 53628.0, - "service_water_heating_peak_flow_per_area": 0.0005165212203, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "OfficeLarge BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "WholeBuilding - Lg Office-others", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Whole Building", - "lighting_secondary_space_type": "Office", - "lighting_per_area": 1.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.75, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.0, - "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeLarge ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Office Buildings", - "ventilation_secondary_space_type": "Whole Building", - "ventilation_per_area": 0.1, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.201599, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": 27.7, - "service_water_heating_area": 53628.0, - "service_water_heating_peak_flow_per_area": 0.0005165212203, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "OfficeLarge BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "WholeBuilding - Md Office", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Whole Building", - "lighting_secondary_space_type": "Office", - "lighting_per_area": 1.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.75, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH_2004", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.0, - "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Office Buildings", - "ventilation_secondary_space_type": "Whole Building", - "ventilation_per_area": 0.1, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_PACU_VAV_bot", - "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": 51.0, - "service_water_heating_area": 53628.0, - "service_water_heating_peak_flow_per_area": 0.0009509957485, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "OfficeMedium BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "Office", - "space_type": "WholeBuilding - Sm Office", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Whole Building", - "lighting_secondary_space_type": "Office", - "lighting_per_area": 1.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OfficeSmall BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.63, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OfficeSmall BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.6, - "occupancy_schedule": "OfficeSmall BLDG_OCC_SCH", - "occupancy_activity_schedule": "OfficeSmall ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Office Buildings", - "ventilation_secondary_space_type": "Whole Building", - "ventilation_per_area": 0.1, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OfficeSmall INFIL_QUARTER_ON_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OfficeSmall HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "OfficeSmall CLGSETP_SCH_NO_OPTIMUM", - "service_water_heating_peak_flow_rate": 3.0, - "service_water_heating_area": 5502.0, - "service_water_heating_peak_flow_per_area": 0.0005452562704, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "OfficeSmall BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "Anesthesia", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Exam/Treatment", - "lighting_per_area": 1.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 2.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 20.02, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "GGHC v2.2", - "ventilation_primary_space_type": "Health Care", - "ventilation_secondary_space_type": "Treatment / Examination", - "ventilation_per_area": 0.3, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": 8.0, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": 2.0, - "service_water_heating_area": 108.0, - "service_water_heating_peak_flow_per_area": 0.01851851852, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", - "exhaust_per_area": 1.3333346236599153, - "exhaust_fan_efficiency": 0.31, - "exhaust_fan_power": 54.520672421626536, - "exhaust_fan_pressure_rise": 1.0, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": "OutPatientHealthCare Hours_of_operation", - "exhaust_flow_fraction_schedule": "OutPatientHealthCare Hours_of_operation", - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "204_120_230" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "BioHazard", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Active Storage", - "lighting_secondary_space_type": "For Hospital", - "lighting_per_area": 0.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.1, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "GGHC v2.2", - "ventilation_primary_space_type": "Health Care", - "ventilation_secondary_space_type": "Bedpan Room", - "ventilation_per_area": 0.15, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "204_120_230" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "Cafe", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 99.89, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Food and Beverage Service", - "ventilation_secondary_space_type": "Cafeteria, fast food", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "31_169_34" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "CleanWork", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Exam/Treatment", - "lighting_per_area": 1.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 2.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 20.02, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "GGHC v2.2", - "ventilation_primary_space_type": "Health Care", - "ventilation_secondary_space_type": "Clean Utility / Workroom", - "ventilation_per_area": 0.3, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": 4.0, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "204_120_230" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "Conference", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Conference/Meeting/Multipurpose", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.3, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 49.95, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Conference rooms", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_196_120" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "DressingRoom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Office-Enclosed", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.1, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.0, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Office Space", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "136_78_222" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "Elec/MechRoom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Electrical/Mechanical", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 5.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Public restrooms", - "ventilation_per_area": 0.0, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "41_31_169" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "ElevatorPumpRoom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Electrical/Mechanical", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 5.3, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.1, - "electric_equipment_fraction_lost": 0.9, - "electric_equipment_schedule": "OutPatientHealthCare ELEV_LIGHT_FAN_SCH_24_7", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Public restrooms", - "ventilation_per_area": 0.0, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "41_31_169" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "Exam", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Exam/Treatment", - "lighting_per_area": 1.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.1, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 20.02, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "GGHC v2.2", - "ventilation_primary_space_type": "Health Care", - "ventilation_secondary_space_type": "Special Procedure Room, Diagnostic", - "ventilation_per_area": 0.3, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": 6.0, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "136_78_222" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "Hall", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Corridor/Transition", - "lighting_secondary_space_type": "For Hospital", - "lighting_per_area": 1.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.4, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_31" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "Hall_infil", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Corridor/Transition", - "lighting_secondary_space_type": "For Hospital", - "lighting_per_area": 1.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.4, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_31" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "IT_Room", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Office-Enclosed", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.1, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.0, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Telecommunication centers and data entry areas", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "41_31_169" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "Janitor", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Active Storage", - "lighting_secondary_space_type": "For Hospital", - "lighting_per_area": 0.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.1, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.3, - "electric_equipment_fraction_lost": 0.7, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "GGHC v2.2", - "ventilation_primary_space_type": "Health Care", - "ventilation_secondary_space_type": "Bathroom/ Public", - "ventilation_per_area": 0.15, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_149_230" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "Lobby", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.3, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.1, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 10.0, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Lobbies", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "LockerRoom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Lounge/Recreation", - "lighting_secondary_space_type": "For Hospital", - "lighting_per_area": 0.8, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 3.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 15.01, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Lobbies", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_169_31" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "Lounge", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Lounge/Recreation", - "lighting_secondary_space_type": "For Hospital", - "lighting_per_area": 0.8, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 3.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 15.01, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Lobbies", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "MRI", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Radiology", - "lighting_per_area": 0.4, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 10.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 20.02, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "GGHC v2.2", - "ventilation_primary_space_type": "Health Care", - "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment", - "ventilation_per_area": 0.3, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": 2.0, - "service_water_heating_area": 440.0, - "service_water_heating_peak_flow_per_area": 0.004545454545, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", - "exhaust_per_area": 1.0000009677449364, - "exhaust_fan_efficiency": 0.31, - "exhaust_fan_power": 166.5909435105255, - "exhaust_fan_pressure_rise": 1.0, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": "OutPatientHealthCare Hours_of_operation", - "exhaust_flow_fraction_schedule": "OutPatientHealthCare Hours_of_operation", - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_159" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "MRI_Control", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Radiology", - "lighting_per_area": 0.4, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 10.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 20.02, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "GGHC v2.2", - "ventilation_primary_space_type": "Health Care", - "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment", - "ventilation_per_area": 0.3, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": 2.0, - "service_water_heating_area": 168.0, - "service_water_heating_peak_flow_per_area": 0.0119047619, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", - "exhaust_per_area": 1.0000009677449364, - "exhaust_fan_efficiency": 0.31, - "exhaust_fan_power": 63.6074511585643, - "exhaust_fan_pressure_rise": 1.0, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": "OutPatientHealthCare Hours_of_operation", - "exhaust_flow_fraction_schedule": "OutPatientHealthCare Hours_of_operation", - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "136_78_222" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "MedGas", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Active Storage", - "lighting_secondary_space_type": "For Hospital", - "lighting_per_area": 0.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.1, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", - "ventilation_secondary_space_type": "Storage rooms", - "ventilation_per_area": 0.15, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "204_120_230" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "NurseStation", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Nurse Station", - "lighting_per_area": 1.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 2.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 20.02, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", - "ventilation_secondary_space_type": "Physical therapy", - "ventilation_per_area": 0.47, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "31_162_169" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "OR", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Operating Room", - "lighting_per_area": 2.2, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": 23.87, - "gas_equipment_fraction_latent": 0.0, - "gas_equipment_fraction_radiant": 0.0, - "gas_equipment_fraction_lost": 0.5, - "gas_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH", - "electric_equipment_per_area": 4.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 20.02, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", - "ventilation_secondary_space_type": "Operating rooms outpatient", - "ventilation_per_area": 0.5, - "ventilation_per_person": 30.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": 20.0, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare OR_HTGSETP_SCH", - "cooling_setpoint_schedule": "OutPatientHealthCare OR_CLGSETP_SCH", - "service_water_heating_peak_flow_rate": 12.0, - "service_water_heating_area": 472.0, - "service_water_heating_peak_flow_per_area": 0.02542372881, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_159" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "Office", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Office-Enclosed", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_OFFICE_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.1, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.0, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Office Space", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "PACU", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Recovery", - "lighting_per_area": 0.8, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 3.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 20.02, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", - "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient", - "ventilation_per_area": 0.533, - "ventilation_per_person": 5.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": 6.0, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": 2.0, - "service_water_heating_area": 316.0, - "service_water_heating_peak_flow_per_area": 0.006329113924, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_159" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "PhysicalTherapy", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Physical Therapy", - "lighting_per_area": 0.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.5, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 20.02, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", - "ventilation_secondary_space_type": "Physical therapy", - "ventilation_per_area": 0.47, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": 6.0, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": 2.0, - "service_water_heating_area": 946, - "service_water_heating_peak_flow_per_area": 0.002114164905, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "154_230_120" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "PreOp", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Patient Room", - "lighting_per_area": 0.7, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 2.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 10.0, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", - "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient", - "ventilation_per_area": 0.533, - "ventilation_per_person": 5.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": 6.0, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": 2.0, - "service_water_heating_area": 263.5, - "service_water_heating_peak_flow_per_area": 0.007590132827, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_159" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "ProcedureRoom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Emergency", - "lighting_per_area": 2.7, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 3.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 20.02, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", - "ventilation_secondary_space_type": "Procedure Room Outpatient", - "ventilation_per_area": 0.8, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": 15.0, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": 2.0, - "service_water_heating_area": 285.0, - "service_water_heating_peak_flow_per_area": 0.00701754386, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_159" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "Reception", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.3, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.1, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 29.97, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Lobbies", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "Soil Work", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Exam/Treatment", - "lighting_per_area": 1.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 2.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 20.02, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "GGHC v2.2", - "ventilation_primary_space_type": "Health Care", - "ventilation_secondary_space_type": "Clean Linen Storage", - "ventilation_per_area": 0.3, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": 10.0, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": 1.6666682795748944, - "exhaust_fan_efficiency": 0.31, - "exhaust_fan_power": 79.50931394820536, - "exhaust_fan_pressure_rise": 1.0, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": "OutPatientHealthCare Hours_of_operation", - "exhaust_flow_fraction_schedule": "OutPatientHealthCare Hours_of_operation", - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "204_120_230" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "Stair", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Corridor/Transition", - "lighting_secondary_space_type": "For Hospital", - "lighting_per_area": 1.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.4, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "Toilet", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Restrooms", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.4, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.3, - "electric_equipment_fraction_lost": 0.7, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Public restrooms", - "ventilation_per_area": 0.0, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": 10.0, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": 1.6666682795748942, - "exhaust_fan_efficiency": 0.31, - "exhaust_fan_power": 34.075420263516584, - "exhaust_fan_pressure_rise": 1.0, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": "OutPatientHealthCare Hours_of_operation", - "exhaust_flow_fraction_schedule": "OutPatientHealthCare Hours_of_operation", - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_169_31" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "Undeveloped", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Active Storage", - "lighting_secondary_space_type": "For Hospital", - "lighting_per_area": 0.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.1, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.3, - "electric_equipment_fraction_lost": 0.7, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "GGHC v2.2", - "ventilation_primary_space_type": "Health Care", - "ventilation_secondary_space_type": "Bathroom/ Public", - "ventilation_per_area": 0.15, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_149_230" - }, - { - "template": "90.1-2004", - "building_type": "Outpatient", - "space_type": "Xray", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Radiology", - "lighting_per_area": 0.4, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 10.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 20.02, - "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", - "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "GGHC v2.2", - "ventilation_primary_space_type": "Health Care", - "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment", - "ventilation_per_area": 0.3, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": 2.0, - "service_water_heating_area": 900.0, - "service_water_heating_peak_flow_per_area": 0.002222222222, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_159" - }, - { - "template": "90.1-2004", - "building_type": "PrimarySchool", - "space_type": "Cafeteria", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.37, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 2.3588, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SchoolPrimary KITCHEN_ELEC_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 100.0, - "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Cafeteria", - "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Food and Beverage Service", - "ventilation_secondary_space_type": "Cafeteria, fast food", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "31_169_34" - }, - { - "template": "90.1-2004", - "building_type": "PrimarySchool", - "space_type": "Classroom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Classroom/Lecture/Training", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.4, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.37, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SchoolPrimary BLDG_LIGHT_CLASSROOM_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.3935, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 25.0, - "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", - "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Education", - "ventilation_secondary_space_type": "Classroom", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "PrimarySchool", - "space_type": "ComputerRoom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Classroom/Lecture/Training", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.4, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.37, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SchoolPrimary BLDG_LIGHT_CLASSROOM_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.8581, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 25.0, - "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", - "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Education", - "ventilation_secondary_space_type": "Classroom", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "PrimarySchool", - "space_type": "Corridor", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Corridor/Transition", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.37, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SchoolPrimary BLDG_LIGHT_CORRIDOR_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.37, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", - "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Education", - "ventilation_secondary_space_type": "Corridors", - "ventilation_per_area": 0.1, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_31" - }, - { - "template": "90.1-2004", - "building_type": "PrimarySchool", - "space_type": "Gym", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Gymnasium/Exercise Center", - "lighting_secondary_space_type": "Exercise Area", - "lighting_per_area": 0.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.37, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SchoolPrimary BLDG_LIGHT_GYM_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.46, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 30.0, - "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Gym", - "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Sports and Amusement", - "ventilation_secondary_space_type": "Playing floors (gymnasium)", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "154_230_120" - }, - { - "template": "90.1-2004", - "building_type": "PrimarySchool", - "space_type": "Kitchen", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Food Preparation", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.2, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.37, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": 453.7, - "gas_equipment_fraction_latent": 0.1, - "gas_equipment_fraction_radiant": 0.2, - "gas_equipment_fraction_lost": 0.7, - "gas_equipment_schedule": "SchoolPrimary KITCHEN_GAS_EQUIP_SCH", - "electric_equipment_per_area": 17.6934, - "electric_equipment_fraction_latent": 0.25, - "electric_equipment_fraction_radiant": 0.3, - "electric_equipment_fraction_lost": 0.2, - "electric_equipment_schedule": "SchoolPrimary KITCHEN_ELEC_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 13.93, - "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", - "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Food and Beverage Service", - "ventilation_secondary_space_type": "Kitchens (cooking)", - "ventilation_per_area": 0.47, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", - "service_water_heating_peak_flow_rate": 100.0, - "service_water_heating_area": 1808.0, - "service_water_heating_peak_flow_per_area": 0.05530973451, - "service_water_heating_system_type": "Dedicated", - "booster_water_heater_fraction": 0.6, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": 180.0, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "SchoolPrimary BLDG_SWH_SCH", - "exhaust_per_area": 0.7, - "exhaust_fan_efficiency": 0.338, - "exhaust_fan_power": 572.9644137011418, - "exhaust_fan_pressure_rise": 0.5, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": "SchoolPrimary Kitchen_Exhaust_SCH", - "exhaust_flow_fraction_schedule": "SchoolPrimary Kitchen_Exhaust_SCH", - "balanced_exhaust_fraction_schedule": "SchoolPrimary Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule", - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "78_222_133" - }, - { - "template": "90.1-2004", - "building_type": "PrimarySchool", - "space_type": "Library", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Whole Building", - "lighting_secondary_space_type": "Library", - "lighting_per_area": 1.3, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.37, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SchoolPrimary BLDG_LIGHT_LIBRARY_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": 0.0, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.3935, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 10.0, - "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", - "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Education", - "ventilation_secondary_space_type": "Libraries", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_196_120" - }, - { - "template": "90.1-2004", - "building_type": "PrimarySchool", - "space_type": "Lobby", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.3, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.37, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SchoolPrimary BLDG_LIGHT_LOBBYFLR1_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.37, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", - "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Education", - "ventilation_secondary_space_type": "Corridors", - "ventilation_per_area": 0.1, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "PrimarySchool", - "space_type": "Mechanical", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Electrical/Mechanical", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.37, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.929, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", - "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "41_31_169" - }, - { - "template": "90.1-2004", - "building_type": "PrimarySchool", - "space_type": "Office", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Office-Enclosed", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.37, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.0, - "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Offices", - "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Office Space", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "PrimarySchool", - "space_type": "Restroom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Restrooms", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.37, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SchoolPrimary BLDG_LIGHT_BATH_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.37, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", - "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)", - "ventilation_per_area": 0.96, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", - "service_water_heating_peak_flow_rate": 56.5, - "service_water_heating_area": 2045.0, - "service_water_heating_peak_flow_per_area": 0.02762836186, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "SchoolPrimary BLDG_SWH_SCH", - "exhaust_per_area": 0.293378304967726, - "exhaust_fan_efficiency": 0.338, - "exhaust_fan_power": 104.17534794566214, - "exhaust_fan_pressure_rise": 0.5, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_169_31" - }, - { - "template": "90.1-2004", - "building_type": "QuickServiceRestaurant", - "space_type": "Attic", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Attics", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": null, - "lighting_fraction_radiant": null, - "lighting_fraction_visible": null, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": null, - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": null, - "electric_equipment_fraction_latent": null, - "electric_equipment_fraction_radiant": null, - "electric_equipment_fraction_lost": null, - "electric_equipment_schedule": null, - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": null, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": null, - "ventilation_primary_space_type": null, - "ventilation_secondary_space_type": null, - "ventilation_per_area": null, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": null, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Always On", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": null, - "cooling_setpoint_schedule": null, - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_149_230" - }, - { - "template": "90.1-2004", - "building_type": "QuickServiceRestaurant", - "space_type": "Dining", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "For Family Dining", - "lighting_per_area": 2.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.37, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "RestaurantFastFood BLDG_LIGHT_DINING_SCH_2004_2007", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 10.85, - "electric_equipment_fraction_latent": 0.25, - "electric_equipment_fraction_radiant": 0.3, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "RestaurantFastFood BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 70.0, - "occupancy_schedule": "RestaurantFastFood BLDG_OCC_SCH", - "occupancy_activity_schedule": "RestaurantFastFood ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Food and Beverage Service", - "ventilation_secondary_space_type": "Cafeteria, fast food", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": null, - "infiltration_per_exterior_wall_area": 0.2016, - "infiltration_air_changes": null, - "infiltration_schedule": "RestaurantFastFood INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "RestaurantFastFood HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "RestaurantFastFood CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "31_169_34" - }, - { - "template": "90.1-2004", - "building_type": "QuickServiceRestaurant", - "space_type": "Kitchen", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Food Preparation", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.2, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "RestaurantFastFood BLDG_LIGHT_KITCHEN_SCH_2004_2007", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": 250.86, - "gas_equipment_fraction_latent": 0.1, - "gas_equipment_fraction_radiant": 0.2, - "gas_equipment_fraction_lost": 0.7, - "gas_equipment_schedule": "RestaurantFastFood FF_GAS_EQUIP_SCH", - "electric_equipment_per_area": 25.166, - "electric_equipment_fraction_latent": 0.25, - "electric_equipment_fraction_radiant": 0.3, - "electric_equipment_fraction_lost": 0.3, - "electric_equipment_schedule": "RestaurantFastFood BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.0, - "occupancy_schedule": "RestaurantFastFood BLDG_OCC_SCH", - "occupancy_activity_schedule": "RestaurantFastFood ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Food and Beverage Service", - "ventilation_secondary_space_type": "Kitchens (cooking)", - "ventilation_per_area": 0.47, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": null, - "infiltration_per_exterior_wall_area": 0.2016, - "infiltration_air_changes": null, - "infiltration_schedule": "RestaurantFastFood INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "RestaurantFastFood HTGSETP_KITCHEN_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "RestaurantFastFood CLGSETP_KITCHEN_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": 40.0, - "service_water_heating_area": 1250.0, - "service_water_heating_peak_flow_per_area": 0.032, - "service_water_heating_system_type": "Dedicated", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "RestaurantFastFood BLDG_SWH_SCH", - "exhaust_per_area": 0.7, - "exhaust_fan_efficiency": 0.338, - "exhaust_fan_power": 575.7279076578998, - "exhaust_fan_pressure_rise": 0.502411575562701, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": "RestaurantFastFood Hours_of_operation", - "exhaust_flow_fraction_schedule": "RestaurantFastFood Hours_of_operation", - "balanced_exhaust_fraction_schedule": "RestaurantFastFood Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule_2004", - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "78_222_133" - }, - { - "template": "90.1-2004", - "building_type": "Retail", - "space_type": "Back_Space", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Active Storage", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.8, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "RetailStandalone BLDG_LIGHT_BACK_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": "This is only used in Tall Building office stories, value for one story. For individual Retail building type, SWH is added via hardcoding to certain zones and Main Service Water Peak FlowRate in \"prototype_input\".", - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.75, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 15.0, - "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH", - "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", - "ventilation_secondary_space_type": "Storage rooms", - "ventilation_per_area": 0.15, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": 18.0, - "service_water_heating_area": 3361.5972, - "service_water_heating_peak_flow_per_area": 0.005354597511, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "RetailStandalone BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_149_230" - }, - { - "template": "90.1-2004", - "building_type": "Retail", - "space_type": "Entry", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.3, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "RetailStandalone BLDG_LIGHT_ENTRY_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.3, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH", - "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", - "ventilation_secondary_space_type": "Basement and street", - "ventilation_per_area": 0.3, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "RetailStandalone FRONT_ENTRY_COOLING", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_31" - }, - { - "template": "90.1-2004", - "building_type": "Retail", - "space_type": "Point_of_Sale", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Retail (not including accent lighting)", - "lighting_secondary_space_type": "Sales Area", - "lighting_per_area": 1.7, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "RetailStandalone BLDG_LIGHT_FRONT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 2.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 15.0, - "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH", - "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", - "ventilation_secondary_space_type": "Basement and street", - "ventilation_per_area": 0.3, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "171_222_78" - }, - { - "template": "90.1-2004", - "building_type": "Retail", - "space_type": "Retail", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Retail (not including accent lighting)", - "lighting_secondary_space_type": "Sales Area", - "lighting_per_area": 1.7, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "RetailStandalone BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.3, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 15.0, - "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH", - "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Specialty Shops", - "ventilation_secondary_space_type": "Clothiers, furniture", - "ventilation_per_area": 0.3, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "171_222_78" - }, - { - "template": "90.1-2004", - "building_type": "SecondarySchool", - "space_type": "Auditorium", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Audience/Seating Area", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.37, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.46, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 150.0, - "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Auditorium", - "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Education", - "ventilation_secondary_space_type": "Auditorium", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC", - "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_196_120" - }, - { - "template": "90.1-2004", - "building_type": "SecondarySchool", - "space_type": "Cafeteria", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.37, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 7.15, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SchoolSecondary KITCHEN_ELEC_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 100.0, - "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Cafeteria", - "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Food and Beverage Service", - "ventilation_secondary_space_type": "Cafeteria, fast food", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC", - "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "31_169_34" - }, - { - "template": "90.1-2004", - "building_type": "SecondarySchool", - "space_type": "Classroom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Classroom/Lecture/Training", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.4, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.37, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SchoolSecondary BLDG_LIGHT_CLASSROOM_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.929, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 35.0, - "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", - "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Education", - "ventilation_secondary_space_type": "Classroom", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "SecondarySchool", - "space_type": "ComputerRoom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Classroom/Lecture/Training", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.4, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.37, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SchoolSecondary BLDG_LIGHT_CLASSROOM_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.858, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 35.0, - "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", - "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Education", - "ventilation_secondary_space_type": "Classroom", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "SecondarySchool", - "space_type": "Corridor", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Corridor/Transition", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.37, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SchoolSecondary BLDG_LIGHT_CORRIDOR_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.37, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", - "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Education", - "ventilation_secondary_space_type": "Corridors", - "ventilation_per_area": 0.1, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_31" - }, - { - "template": "90.1-2004", - "building_type": "SecondarySchool", - "space_type": "Gym", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Gymnasium/Exercise Center", - "lighting_secondary_space_type": "Playing Area", - "lighting_per_area": 1.4, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.37, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SchoolSecondary BLDG_LIGHT_GYM_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.46, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 30.0, - "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Gym", - "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Sports and Amusement", - "ventilation_secondary_space_type": "Playing floors (gymnasium)", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC", - "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": 159.5, - "service_water_heating_area": 21269.0, - "service_water_heating_peak_flow_per_area": 0.007499177206, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "154_230_120" - }, - { - "template": "90.1-2004", - "building_type": "SecondarySchool", - "space_type": "Kitchen", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Food Preparation", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.2, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.37, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": 532.1, - "gas_equipment_fraction_latent": 0.1, - "gas_equipment_fraction_radiant": 0.2, - "gas_equipment_fraction_lost": 0.7, - "gas_equipment_schedule": "SchoolSecondary KITCHEN_GAS_EQUIP_SCH", - "electric_equipment_per_area": 20.65, - "electric_equipment_fraction_latent": 0.25, - "electric_equipment_fraction_radiant": 0.3, - "electric_equipment_fraction_lost": 0.2, - "electric_equipment_schedule": "SchoolSecondary KITCHEN_ELEC_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 15.23, - "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", - "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Food and Beverage Service", - "ventilation_secondary_space_type": "Kitchens (cooking)", - "ventilation_per_area": 0.47, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC", - "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": 133.0, - "service_water_heating_area": 2325.0, - "service_water_heating_peak_flow_per_area": 0.05720430108, - "service_water_heating_system_type": "Dedicated", - "booster_water_heater_fraction": 0.6, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": 180.0, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH", - "exhaust_per_area": 0.7, - "exhaust_fan_efficiency": 0.338, - "exhaust_fan_power": 694.5023196377475, - "exhaust_fan_pressure_rise": 0.5, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": "SchoolSecondary Kitchen_Exhaust_SCH", - "exhaust_flow_fraction_schedule": "SchoolSecondary Kitchen_Exhaust_SCH", - "balanced_exhaust_fraction_schedule": "SchoolSecondary Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule", - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "78_222_133" - }, - { - "template": "90.1-2004", - "building_type": "SecondarySchool", - "space_type": "Library", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Whole Building", - "lighting_secondary_space_type": "Library", - "lighting_per_area": 1.3, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.37, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SchoolSecondary BLDG_LIGHT_LIBRARY_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.93, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 10.0, - "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", - "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Education", - "ventilation_secondary_space_type": "Libraries", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_196_120" - }, - { - "template": "90.1-2004", - "building_type": "SecondarySchool", - "space_type": "Lobby", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.3, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.37, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SchoolSecondary BLDG_LIGHT_LOBBYFLR1_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.37, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", - "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Reception Areas", - "ventilation_per_area": null, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "SecondarySchool", - "space_type": "Mechanical", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Electrical/Mechanical", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.37, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SchoolSecondary BLDG_LIGHT_MECHANICAL_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.37, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", - "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_Setback", - "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_Setback", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "41_31_169" - }, - { - "template": "90.1-2004", - "building_type": "SecondarySchool", - "space_type": "Office", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Office-Enclosed", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.37, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SchoolSecondary BLDG_LIGHT_OFFICE_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.0, - "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Offices", - "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Office Space", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM", - "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "SecondarySchool", - "space_type": "Restroom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Restrooms", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.37, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SchoolSecondary BLDG_LIGHT_BATH_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.37, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", - "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)", - "ventilation_per_area": 0.96, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_Setback", - "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_Setback", - "service_water_heating_peak_flow_rate": 52.2, - "service_water_heating_area": 2260.0, - "service_water_heating_peak_flow_per_area": 0.02309734513, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH", - "exhaust_per_area": 0.2812153843741127, - "exhaust_fan_efficiency": 0.338, - "exhaust_fan_power": 110.36763444376396, - "exhaust_fan_pressure_rise": 0.5, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_169_31" - }, - { - "template": "90.1-2004", - "building_type": "SmallDataCenterHighITE", - "space_type": "ComputerRoom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "OfficeLarge", - "lighting_secondary_space_type": "Data Center", - "lighting_per_area": 1.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "DataCenter Lighting_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 100.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.1, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "DataCenter Equipment_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": null, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-2007", - "ventilation_primary_space_type": "Miscellaneous Spaces", - "ventilation_secondary_space_type": "Computer (not printing)", - "ventilation_per_area": 0.06, - "ventilation_per_person": 5.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": null, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": null, - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "DataCenter HTGSETP_SCH", - "cooling_setpoint_schedule": "DataCenter CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_31" - }, - { - "template": "90.1-2004", - "building_type": "SmallDataCenterLowITE", - "space_type": "ComputerRoom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "OfficeLarge", - "lighting_secondary_space_type": "Data Center", - "lighting_per_area": 1.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": null, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "DataCenter Lighting_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 40.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.1, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "DataCenter Equipment_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": null, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-2007", - "ventilation_primary_space_type": "Miscellaneous Spaces", - "ventilation_secondary_space_type": "Computer (not printing)", - "ventilation_per_area": 0.06, - "ventilation_per_person": 5.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": null, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": null, - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "DataCenter HTGSETP_SCH", - "cooling_setpoint_schedule": "DataCenter CLGSETP_SCH", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_31" - }, - { - "template": "90.1-2004", - "building_type": "SmallHotel", - "space_type": "Corridor", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Corridor/Transition", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelSmall BLDG_LIGHT_CORRIDOR_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelSmall AlwaysOff", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "HotelSmall AlwaysOff", - "occupancy_activity_schedule": "HotelSmall Activity_Sch", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.2016, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Always On", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", - "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_31" - }, - { - "template": "90.1-2004", - "building_type": "SmallHotel", - "space_type": "Corridor4", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Corridor/Transition", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelSmall BLDG_LIGHT_CORRIDOR_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelSmall AlwaysOff", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "HotelSmall AlwaysOff", - "occupancy_activity_schedule": "HotelSmall Activity_Sch", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0258, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Always On", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", - "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_31" - }, - { - "template": "90.1-2004", - "building_type": "SmallHotel", - "space_type": "Elec/MechRoom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "SmallHotel", - "lighting_secondary_space_type": "Elec/MechRoom", - "lighting_per_area": 0.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelSmall AlwaysOff", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 198.2, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelSmall BLDG_ELEVATORS", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.2016, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Always On", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": null, - "cooling_setpoint_schedule": null, - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "41_31_174" - }, - { - "template": "90.1-2004", - "building_type": "SmallHotel", - "space_type": "ElevatorCore", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "SmallHotel", - "lighting_secondary_space_type": "ElevatorCore", - "lighting_per_area": 0.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelSmall AlwaysOff", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": null, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelSmall BLDG_ELEVATORS", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.2016, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Always On", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": null, - "cooling_setpoint_schedule": null, - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "41_31_174" - }, - { - "template": "90.1-2004", - "building_type": "SmallHotel", - "space_type": "ElevatorCore4", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "SmallHotel", - "lighting_secondary_space_type": "ElevatorCore", - "lighting_per_area": 0.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelSmall AlwaysOff", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": null, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelSmall BLDG_ELEVATORS", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": null, - "occupancy_activity_schedule": null, - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.05042, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Always On", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": null, - "cooling_setpoint_schedule": null, - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "41_31_174" - }, - { - "template": "90.1-2004", - "building_type": "SmallHotel", - "space_type": "Exercise", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Gymnasium/Exercise Center", - "lighting_secondary_space_type": "Exercise Area", - "lighting_per_area": 0.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelSmall BLDG_LIGHT_EXERCENTER_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.73, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelSmall ExerciseCenter_Eqp_Sch", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 19.94, - "occupancy_schedule": "HotelSmall ExerciseCenter_Occ_Sch", - "occupancy_activity_schedule": "HotelSmall Activity_Sch", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Sports and Amusement", - "ventilation_secondary_space_type": "Spectator areas", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.2016, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", - "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "154_230_120" - }, - { - "template": "90.1-2004", - "building_type": "SmallHotel", - "space_type": "GuestLounge", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "For Hotel", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelSmall BLDG_LIGHT_FRONTLOUNGE_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 2.42, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelSmall Lobby_Eqp_Sch", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 30.0, - "occupancy_schedule": "HotelSmall Lobby_Occ_Sch", - "occupancy_activity_schedule": "HotelSmall Activity_Sch", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Lobbies", - "ventilation_per_area": 0.0, - "ventilation_per_person": 15.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.2016, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", - "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "SmallHotel", - "space_type": "GuestRoom123Occ", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hotel/Motel", - "lighting_secondary_space_type": "Guest Rooms", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SmallHotel GuestRoom Light", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.1, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelSmall GuestRoom_Eqp_Sch_Base", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 4.27, - "occupancy_schedule": "HotelSmall GuestRoom_Occ_Sch", - "occupancy_activity_schedule": "HotelSmall Activity_Sch", - "is_residential": "Yes", - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Bedrooms", - "ventilation_per_area": 0.1, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.2016, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelSmall Base_OccGuestRoom_HtgSP_Sch", - "cooling_setpoint_schedule": "HotelSmall Base_OccGuestRoom_ClgSP_Sch", - "service_water_heating_peak_flow_rate": 2.22, - "service_water_heating_area": 351.0, - "service_water_heating_peak_flow_per_area": 0.006324786325, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "HotelSmall GuestRoom_SHW_Sch", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "78_167_222" - }, - { - "template": "90.1-2004", - "building_type": "SmallHotel", - "space_type": "GuestRoom123Vac", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hotel/Motel", - "lighting_secondary_space_type": "Guest Rooms", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelSmall AlwaysOff", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.1, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelSmall AlwaysOff", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 4.27, - "occupancy_schedule": "HotelSmall AlwaysOff", - "occupancy_activity_schedule": "HotelSmall Activity_Sch", - "is_residential": "Yes", - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Bedrooms", - "ventilation_per_area": 0.1, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.2016, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelSmall VacGuestRoom_HtgSP_Sch", - "cooling_setpoint_schedule": "HotelSmall VacGuestRoom_ClgSP_Sch", - "service_water_heating_peak_flow_rate": 2.22, - "service_water_heating_area": 351.0, - "service_water_heating_peak_flow_per_area": 0.006324786325, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "HotelSmall AlwaysOff", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "78_167_222" - }, - { - "template": "90.1-2004", - "building_type": "SmallHotel", - "space_type": "GuestRoom4Occ", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hotel/Motel", - "lighting_secondary_space_type": "Guest Rooms", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SmallHotel GuestRoom Light", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.1, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelSmall GuestRoom_Eqp_Sch_Base", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 4.27, - "occupancy_schedule": "HotelSmall GuestRoom_Occ_Sch", - "occupancy_activity_schedule": "HotelSmall Activity_Sch", - "is_residential": "Yes", - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Bedrooms", - "ventilation_per_area": 0.1, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0504, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelSmall Base_OccGuestRoom_HtgSP_Sch", - "cooling_setpoint_schedule": "HotelSmall Base_OccGuestRoom_ClgSP_Sch", - "service_water_heating_peak_flow_rate": 2.22, - "service_water_heating_area": 351.0, - "service_water_heating_peak_flow_per_area": 0.006324786325, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "HotelSmall GuestRoom_SHW_Sch", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "78_167_222" - }, - { - "template": "90.1-2004", - "building_type": "SmallHotel", - "space_type": "GuestRoom4Vac", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hotel/Motel", - "lighting_secondary_space_type": "Guest Rooms", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelSmall AlwaysOff", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.1, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelSmall AlwaysOff", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 4.27, - "occupancy_schedule": "HotelSmall AlwaysOff", - "occupancy_activity_schedule": "HotelSmall Activity_Sch", - "is_residential": "Yes", - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Bedrooms", - "ventilation_per_area": 0.1, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0504, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelSmall VacGuestRoom_HtgSP_Sch", - "cooling_setpoint_schedule": "HotelSmall VacGuestRoom_ClgSP_Sch", - "service_water_heating_peak_flow_rate": 2.22, - "service_water_heating_area": 351.0, - "service_water_heating_peak_flow_per_area": 0.006324786325, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "HotelSmall AlwaysOff", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "78_167_222" - }, - { - "template": "90.1-2004", - "building_type": "SmallHotel", - "space_type": "Laundry", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Laundry-Washing", - "lighting_per_area": 0.6, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelSmall BLDG_LIGHT_LAUNDRY_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": 129.9, - "gas_equipment_fraction_latent": 0.0, - "gas_equipment_fraction_radiant": 0.2, - "gas_equipment_fraction_lost": 0.0, - "gas_equipment_schedule": "HotelSmall LaundryRoom_Eqp_Gas_Sch", - "electric_equipment_per_area": 2.57, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.2, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelSmall LaundryRoom_Eqp_Elec_Sch", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 10.0, - "occupancy_schedule": "HotelSmall LaundryRoom_Occ_Sch", - "occupancy_activity_schedule": "HotelSmall Activity_Sch", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Dry Cleaners, Laundries", - "ventilation_secondary_space_type": "Commercial Laundry", - "ventilation_per_area": 0.0, - "ventilation_per_person": 25.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.2016, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", - "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", - "service_water_heating_peak_flow_rate": 67.5, - "service_water_heating_area": 1053.0, - "service_water_heating_peak_flow_per_area": 0.0641025641, - "service_water_heating_system_type": "Dedicated", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 180.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "HotelSmall LaundryRoom_SHW_Sch", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_149_230" - }, - { - "template": "90.1-2004", - "building_type": "SmallHotel", - "space_type": "Mechanical", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Electrical/Mechanical", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelSmall BLDG_LIGHT_MECHROOM_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": 0.0, - "gas_equipment_fraction_radiant": 0.2, - "gas_equipment_fraction_lost": 0.5, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.2, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelSmall AlwaysOff", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "HotelSmall AlwaysOff", - "occupancy_activity_schedule": "HotelSmall Activity_Sch", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.2016, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", - "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "41_31_169" - }, - { - "template": "90.1-2004", - "building_type": "SmallHotel", - "space_type": "Meeting", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Conference/Meeting/Multipurpose", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.3, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelSmall BLDG_LIGHT_MEETINGROOM_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.574, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelSmall MeetingRoom_Eqp_Sch", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 50.0, - "occupancy_schedule": "HotelSmall MeetingRoom_Occ_Sch", - "occupancy_activity_schedule": "HotelSmall Activity_Sch", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Conference rooms", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.2016, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", - "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_196_120" - }, - { - "template": "90.1-2004", - "building_type": "SmallHotel", - "space_type": "Office", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Office-Enclosed", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SmallHotel Office Light", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.28, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelSmall OFF_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 7.14, - "occupancy_schedule": "HotelSmall Office_Occ_Sch", - "occupancy_activity_schedule": "HotelSmall Activity_Sch", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Office Space", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.2016, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", - "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - }, - { - "template": "90.1-2004", - "building_type": "SmallHotel", - "space_type": "PublicRestroom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Restrooms", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Always On", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelSmall Lobby_Eqp_Sch", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 2.85, - "occupancy_schedule": "HotelSmall Lobby_Occ_Sch", - "occupancy_activity_schedule": "HotelSmall Activity_Sch", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Public restrooms", - "ventilation_per_area": 0.0, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.2016, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", - "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": 1.139566144206643, - "exhaust_fan_efficiency": 0.338, - "exhaust_fan_power": 69.45023196377475, - "exhaust_fan_pressure_rise": 0.5, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_169_31" - }, - { - "template": "90.1-2004", - "building_type": "SmallHotel", - "space_type": "StaffLounge", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Lounge/Recreation", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.2, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "HotelSmall BLDG_LIGHT_EMPLOYEELOUNGE_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 2.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelSmall EmployeeLounge_Eqp_Sch", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 51.28, - "occupancy_schedule": "HotelSmall EmployeeLounge_Occ_Sch", - "occupancy_activity_schedule": "HotelSmall Activity_Sch", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", - "ventilation_secondary_space_type": "Conference rooms", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.2016, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", - "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "31_169_34" - }, - { - "template": "90.1-2004", - "building_type": "SmallHotel", - "space_type": "Stair", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Stairs-Active", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.6, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Always On", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelSmall AlwaysOff", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "HotelSmall AlwaysOff", - "occupancy_activity_schedule": "HotelSmall Activity_Sch", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.2016, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Always On", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", - "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "SmallHotel", - "space_type": "Stair4", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Stairs-Active", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.6, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Always On", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelSmall AlwaysOff", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "HotelSmall AlwaysOff", - "occupancy_activity_schedule": "HotelSmall Activity_Sch", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.1196, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Always On", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", - "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "SmallHotel", - "space_type": "Storage", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Active Storage", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.8, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SmallHotel Storage Light", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelSmall AlwaysOff", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "HotelSmall AlwaysOff", - "occupancy_activity_schedule": "HotelSmall Activity_Sch", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", - "ventilation_secondary_space_type": "Storage rooms", - "ventilation_per_area": 0.15, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.2016, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Always On", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", - "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_149_230" - }, - { - "template": "90.1-2004", - "building_type": "SmallHotel", - "space_type": "Storage4Front", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Active Storage", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.8, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SmallHotel Storage Light", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelSmall AlwaysOff", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "HotelSmall AlwaysOff", - "occupancy_activity_schedule": "HotelSmall Activity_Sch", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", - "ventilation_secondary_space_type": "Storage rooms", - "ventilation_per_area": 0.15, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0504, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Always On", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", - "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_149_230" - }, - { - "template": "90.1-2004", - "building_type": "SmallHotel", - "space_type": "Storage4Rear", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Active Storage", - "lighting_secondary_space_type": "General", - "lighting_per_area": 0.8, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SmallHotel Storage Light", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "HotelSmall AlwaysOff", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "HotelSmall AlwaysOff", - "occupancy_activity_schedule": "HotelSmall Activity_Sch", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", - "ventilation_secondary_space_type": "Storage rooms", - "ventilation_per_area": 0.15, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.1196, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Always On", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", - "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_149_230" - }, - { - "template": "90.1-2004", - "building_type": "StripMall", - "space_type": "Strip mall - type 1", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Whole Building", - "lighting_secondary_space_type": "Retail", - "lighting_per_area": 1.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": 0.975, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "RetailStripmall Type1_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.4, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "RetailStripmall Type1_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 8.0, - "occupancy_schedule": "RetailStripmall Type1_OCC_SCH", - "occupancy_activity_schedule": "HotelSmall Activity_Sch", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", - "ventilation_secondary_space_type": "Basement and street", - "ventilation_per_area": 0.3, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0891675017, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "RetailStripmall Type1_Infil_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "RetailStripmall Type1_HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "RetailStripmall Type1_CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": 1.8, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": "One Per Unit", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "RetailStripmall Type1_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "171_222_78" - }, - { - "template": "90.1-2004", - "building_type": "StripMall", - "space_type": "Strip mall - type 2", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Whole Building", - "lighting_secondary_space_type": "Retail", - "lighting_per_area": 1.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": 0.4, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "RetailStripmall Type2_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.4, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "RetailStripmall Type2_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 8.0, - "occupancy_schedule": "RetailStripmall Type2_OCC_SCH", - "occupancy_activity_schedule": "HotelSmall Activity_Sch", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", - "ventilation_secondary_space_type": "Basement and street", - "ventilation_per_area": 0.3, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0628789142, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "RetailStripmall Type2_Infil_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "RetailStripmall Type2_HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "RetailStripmall Type2_CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": 1.8, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": "One Per Unit", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "RetailStripmall Type2_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "171_222_78" - }, - { - "template": "90.1-2004", - "building_type": "StripMall", - "space_type": "Strip mall - type 3", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Whole Building", - "lighting_secondary_space_type": "Retail", - "lighting_per_area": 1.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "RetailStripmall Type3_LIGHT_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.4, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "RetailStripmall Type3_EQUIP_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 8.0, - "occupancy_schedule": "RetailStripmall Type3_OCC_SCH", - "occupancy_activity_schedule": "HotelSmall Activity_Sch", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", - "ventilation_secondary_space_type": "Basement and street", - "ventilation_per_area": 0.3, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0628789142, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "RetailStripmall Type3_Infil_SCH", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "RetailStripmall Type3_HTGSETP_SCH_NO_OPTIMUM", - "cooling_setpoint_schedule": "RetailStripmall Type3_CLGSETP_SCH_NO_SETBACK", - "service_water_heating_peak_flow_rate": 1.8, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": "One Per Unit", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "RetailStripmall Type3_SWH_SCH", - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "171_222_78" - }, - { - "template": "90.1-2004", - "building_type": "SuperMarket", - "space_type": "Bakery", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Supermarket", - "lighting_secondary_space_type": "Deli/Bakery", - "lighting_per_area": 1.2, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SuperMarket Bldg Light", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": 8.53, - "gas_equipment_fraction_latent": 0.1, - "gas_equipment_fraction_radiant": 0.2, - "gas_equipment_fraction_lost": 0.7, - "gas_equipment_schedule": "SuperMarket Gas Equip New", - "electric_equipment_per_area": 0.01, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SuperMarket Bldg Equip New", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 8.0, - "occupancy_schedule": "SuperMarket Bldg Occ", - "occupancy_activity_schedule": "SuperMarket Activity", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Food and Beverage Service", - "ventilation_secondary_space_type": "Kitchens (cooking)", - "ventilation_per_area": 0.47, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SuperMarket Infil New", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SuperMarket HtgSetp", - "cooling_setpoint_schedule": "SuperMarket ClgSetp", - "service_water_heating_peak_flow_rate": 5.0, - "service_water_heating_area": 2334.5, - "service_water_heating_peak_flow_per_area": 0.00214178625, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "SuperMarket Bldg Swh", - "exhaust_per_area": 1.2402518232437685, - "exhaust_fan_efficiency": 0.338, - "exhaust_fan_power": 520.8767397283107, - "exhaust_fan_pressure_rise": 0.5, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": "SuperMarket HVACOperationSchd", - "exhaust_flow_fraction_schedule": "SuperMarket HVACOperationSchd", - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "31_169_34" - }, - { - "template": "90.1-2004", - "building_type": "SuperMarket", - "space_type": "Corridor", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Supermarket", - "lighting_secondary_space_type": "Corridor", - "lighting_per_area": 0.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SuperMarket Bldg Light", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SuperMarket Bldg Equip New", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 8.0, - "occupancy_schedule": "SuperMarket Bldg Occ", - "occupancy_activity_schedule": "SuperMarket Activity", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SuperMarket Infil New", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SuperMarket HtgSetp", - "cooling_setpoint_schedule": "SuperMarket ClgSetp", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_31" - }, - { - "template": "90.1-2004", - "building_type": "SuperMarket", - "space_type": "Deli", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Supermarket", - "lighting_secondary_space_type": "Deli/Bakery", - "lighting_per_area": 1.2, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SuperMarket Bldg Light", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": 8.53, - "gas_equipment_fraction_latent": 0.1, - "gas_equipment_fraction_radiant": 0.2, - "gas_equipment_fraction_lost": 0.7, - "gas_equipment_schedule": "SuperMarket Gas Equip New", - "electric_equipment_per_area": 0.83, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SuperMarket Bldg Equip New", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 8.0, - "occupancy_schedule": "SuperMarket Bldg Occ", - "occupancy_activity_schedule": "SuperMarket Activity", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Food and Beverage Service", - "ventilation_secondary_space_type": "Kitchens (cooking)", - "ventilation_per_area": 0.47, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SuperMarket Infil New", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SuperMarket HtgSetp", - "cooling_setpoint_schedule": "SuperMarket ClgSetp", - "service_water_heating_peak_flow_rate": 5.0, - "service_water_heating_area": 2334.5, - "service_water_heating_peak_flow_per_area": 0.00214178625, - "service_water_heating_system_type": "Shared", - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": 140.0, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": 0.2, - "service_water_heating_fraction_latent": 0.05, - "service_water_heating_schedule": "SuperMarket Bldg Swh", - "exhaust_per_area": 1.2402518232437685, - "exhaust_fan_efficiency": 0.338, - "exhaust_fan_power": 520.8767397283107, - "exhaust_fan_pressure_rise": 0.5, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": "SuperMarket HVACOperationSchd", - "exhaust_flow_fraction_schedule": "SuperMarket HVACOperationSchd", - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "31_169_34" - }, - { - "template": "90.1-2004", - "building_type": "SuperMarket", - "space_type": "Dining", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Supermarket", - "lighting_secondary_space_type": "Dining", - "lighting_per_area": 0.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SuperMarket Bldg Light", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 3.83, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SuperMarket Bldg Equip New", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 70.0, - "occupancy_schedule": "SuperMarket Bldg Occ", - "occupancy_activity_schedule": "SuperMarket Activity", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Food and Beverage Service", - "ventilation_secondary_space_type": "Dining rooms", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SuperMarket Infil New", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SuperMarket HtgSetp", - "cooling_setpoint_schedule": "SuperMarket ClgSetp", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_157_120" - }, - { - "template": "90.1-2004", - "building_type": "SuperMarket", - "space_type": "DryStorage", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Supermarket", - "lighting_secondary_space_type": "DryStorage", - "lighting_per_area": 0.8, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SuperMarket Bldg Light", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.31, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SuperMarket Bldg Equip New", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 3.34, - "occupancy_schedule": "SuperMarket Bldg Occ", - "occupancy_activity_schedule": "SuperMarket Activity", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", - "ventilation_secondary_space_type": "Shipping and receiving", - "ventilation_per_area": 0.15, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SuperMarket Infil New", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SuperMarket HtgSetp", - "cooling_setpoint_schedule": "SuperMarket ClgSetp", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_169_31" - }, - { - "template": "90.1-2004", - "building_type": "SuperMarket", - "space_type": "Elec/MechRoom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Supermarket", - "lighting_secondary_space_type": "Elec/Mech", - "lighting_per_area": 1.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SuperMarket Bldg Light", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SuperMarket Bldg Equip New", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "SuperMarket Bldg Occ", - "occupancy_activity_schedule": "SuperMarket Activity", - "is_residential": null, - "ventilation_standard": null, - "ventilation_primary_space_type": null, - "ventilation_secondary_space_type": null, - "ventilation_per_area": null, - "ventilation_per_person": null, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SuperMarket Infil New", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SuperMarket HtgSetp", - "cooling_setpoint_schedule": "SuperMarket ClgSetp", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "41_31_169" - }, - { - "template": "90.1-2004", - "building_type": "SuperMarket", - "space_type": "Meeting", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Supermarket", - "lighting_secondary_space_type": "Meeting", - "lighting_per_area": 1.3, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SuperMarket Bldg Light", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SuperMarket Bldg Equip New", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 50.0, - "occupancy_schedule": "SuperMarket Bldg Occ", - "occupancy_activity_schedule": "SuperMarket Activity", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Conference rooms", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SuperMarket Infil New", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SuperMarket HtgSetp", - "cooling_setpoint_schedule": "SuperMarket ClgSetp", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "230_196_120" - }, - { - "template": "90.1-2004", - "building_type": "SuperMarket", - "space_type": "Office", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Supermarket", - "lighting_secondary_space_type": "Office", - "lighting_per_area": 1.1, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SuperMarket Bldg Light", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SuperMarket Bldg Equip New", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 5.0, - "occupancy_schedule": "SuperMarket Bldg Occ", - "occupancy_activity_schedule": "SuperMarket Activity", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Office space", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SuperMarket Infil New", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SuperMarket HtgSetp", - "cooling_setpoint_schedule": "SuperMarket ClgSetp", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_169_31" - }, - { - "template": "90.1-2004", - "building_type": "SuperMarket", - "space_type": "Produce", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Supermarket", - "lighting_secondary_space_type": "Sales/Produce", - "lighting_per_area": 1.7, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SuperMarket Bldg Light", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.05, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SuperMarket Bldg Equip New", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 8.0, - "occupancy_schedule": "SuperMarket Bldg Occ", - "occupancy_activity_schedule": "SuperMarket Activity", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", - "ventilation_secondary_space_type": "Basement and street", - "ventilation_per_area": 0.3, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SuperMarket Infil New", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SuperMarket HtgSetp", - "cooling_setpoint_schedule": "SuperMarket ClgSetp", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_169_31" - }, - { - "template": "90.1-2004", - "building_type": "SuperMarket", - "space_type": "Restroom", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Supermarket", - "lighting_secondary_space_type": "Restroom", - "lighting_per_area": 0.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SuperMarket Bldg Light", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SuperMarket Bldg Equip New", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 8.0, - "occupancy_schedule": "SuperMarket Bldg Occ", - "occupancy_activity_schedule": "SuperMarket Activity", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Public restrooms", - "ventilation_per_area": 1.04, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SuperMarket Infil New", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SuperMarket HtgSetp", - "cooling_setpoint_schedule": "SuperMarket ClgSetp", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_169_31" - }, - { - "template": "90.1-2004", - "building_type": "SuperMarket", - "space_type": "Sales", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Supermarket", - "lighting_secondary_space_type": "Sales/Produce", - "lighting_per_area": 1.7, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SuperMarket Bldg Light", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 1.02, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SuperMarket Bldg Equip New", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 8.0, - "occupancy_schedule": "SuperMarket Bldg Occ", - "occupancy_activity_schedule": "SuperMarket Activity", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", - "ventilation_secondary_space_type": "Basement and street", - "ventilation_per_area": 0.3, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SuperMarket Infil New", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SuperMarket HtgSetp", - "cooling_setpoint_schedule": "SuperMarket ClgSetp", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_169_31" - }, - { - "template": "90.1-2004", - "building_type": "SuperMarket", - "space_type": "Vestibule", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Supermarket", - "lighting_secondary_space_type": "Vestibule", - "lighting_per_area": 0.5, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.7, - "lighting_fraction_visible": 0.2, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "SuperMarket Bldg Light", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "SuperMarket Bldg Equip New", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 8.0, - "occupancy_schedule": "SuperMarket Bldg Occ", - "occupancy_activity_schedule": "SuperMarket Activity", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Public Spaces", - "ventilation_secondary_space_type": "Corridors and utilities", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0595, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "SuperMarket Infil New", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "SuperMarket Vestibule HtgSetp", - "cooling_setpoint_schedule": "SuperMarket Vestibule ClgSetp", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": null, - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "169_31_31" - }, - { - "template": "90.1-2004", - "building_type": "Warehouse", - "space_type": "Bulk", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Warehouse", - "lighting_secondary_space_type": "Medium/Bulky Material Storage", - "lighting_per_area": 0.9, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.42, - "lighting_fraction_visible": 0.18, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Warehouse BLDG_LIGHT_STORAGE_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.237684638, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Warehouse Bldg Equip", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "Warehouse BLDG_OCC_SCH", - "occupancy_activity_schedule": "Warehouse Office Activity Schedule", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", - "ventilation_secondary_space_type": "Warehouses", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0444, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Warehouse Bulk Infil Schedule", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Warehouse Bulk Storage Heating Setpoint Schedule", - "cooling_setpoint_schedule": "Warehouse ClgSetp BulkStorage", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "41_31_169" - }, - { - "template": "90.1-2004", - "building_type": "Warehouse", - "space_type": "Fine", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Warehouse", - "lighting_secondary_space_type": "Fine Material Storage", - "lighting_per_area": 1.4, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.42, - "lighting_fraction_visible": 0.18, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Warehouse BLDG_LIGHT_STORAGE_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.0, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Warehouse Bldg Equip", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 0.0, - "occupancy_schedule": "Warehouse BLDG_OCC_SCH", - "occupancy_activity_schedule": "Warehouse Office Activity Schedule", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", - "ventilation_secondary_space_type": "Warehouses", - "ventilation_per_area": 0.05, - "ventilation_per_person": 0.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0444, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Warehouse Fine Infil Schedule", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Warehouse Fine Storage Heating Setpoint Schedule", - "cooling_setpoint_schedule": "Warehouse Fine Storage Cooling Setpoint Schedule", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_149_230" - }, - { - "template": "90.1-2004", - "building_type": "Warehouse", - "space_type": "Office", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_primary_space_type": "Office-Enclosed", - "lighting_secondary_space_type": "General", - "lighting_per_area": 1.0, - "rcr_threshold": null, - "lighting_per_person": null, - "additional_lighting_per_area": null, - "lighting_fraction_to_return_air": 0.0, - "lighting_fraction_radiant": 0.37, - "lighting_fraction_visible": 0.18, - "lighting_fraction_replaceable": 1.0, - "lpd_fraction_linear_fluorescent": 1.0, - "lpd_fraction_compact_fluorescent": null, - "lpd_fraction_high_bay": null, - "lpd_fraction_specialty_lighting": null, - "lpd_fraction_exit_lighting": null, - "lighting_schedule": "Warehouse BLDG_LIGHT_OFFICE_SCH", - "compact_fluorescent_lighting_schedule": null, - "high_bay_lighting_schedule": null, - "specialty_lighting_schedule": null, - "exit_lighting_schedule": null, - "target_illuminance_setpoint": null, - "psa_nongeometry_fraction": null, - "ssa_nongeometry_fraction": null, - "notes": null, - "gas_equipment_per_area": null, - "gas_equipment_fraction_latent": null, - "gas_equipment_fraction_radiant": null, - "gas_equipment_fraction_lost": null, - "gas_equipment_schedule": null, - "electric_equipment_per_area": 0.75, - "electric_equipment_fraction_latent": 0.0, - "electric_equipment_fraction_radiant": 0.5, - "electric_equipment_fraction_lost": 0.0, - "electric_equipment_schedule": "Warehouse Office_Plug_SCH", - "additional_electric_equipment_schedule": null, - "additional_gas_equipment_schedule": null, - "occupancy_per_area": 1.96, - "occupancy_schedule": "Warehouse BLDG_OCC_SCH", - "occupancy_activity_schedule": "Warehouse Office Activity Schedule", - "is_residential": null, - "ventilation_standard": "ASHRAE 62.1-1999", - "ventilation_primary_space_type": "Offices", - "ventilation_secondary_space_type": "Office Space", - "ventilation_per_area": 0.0, - "ventilation_per_person": 20.0, - "ventilation_air_changes": null, - "minimum_total_air_changes": null, - "infiltration_per_exterior_area": 0.0433, - "infiltration_per_exterior_wall_area": null, - "infiltration_air_changes": null, - "infiltration_schedule": "Warehouse Office Infil Schedule", - "infiltration_schedule_perimeter": null, - "heating_setpoint_schedule": "Warehouse HtgSetp", - "cooling_setpoint_schedule": "Warehouse ClgSetp", - "service_water_heating_peak_flow_rate": null, - "service_water_heating_area": null, - "service_water_heating_peak_flow_per_area": "", - "service_water_heating_system_type": null, - "booster_water_heater_fraction": null, - "service_water_heating_target_temperature": null, - "booster_water_heating_target_temperature": null, - "service_water_heating_fraction_sensible": null, - "service_water_heating_fraction_latent": null, - "service_water_heating_schedule": null, - "exhaust_per_area": null, - "exhaust_fan_efficiency": null, - "exhaust_fan_power": null, - "exhaust_fan_pressure_rise": null, - "exhaust_fan_maximum_flow_rate": null, - "exhaust_availability_schedule": null, - "exhaust_flow_fraction_schedule": null, - "balanced_exhaust_fraction_schedule": null, - "manual_continuous_dimming": null, - "programmable_multilevel_dimming": null, - "multilevel_occupancy_sensors": null, - "occupancy_sensors": null, - "occupancy_sensors_with_personal_continuous_dimming": null, - "automatic_multilevel_switching_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, - "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, - "rgb": "120_230_199" - } - ] + { + "template": "90.1-2004", + "space_type": "Office", + "lighting_standard": "ASHRAE 90.1-2004", + "lighting_primary_space_type": "Office", + "lighting_secondary_space_type": "Office", + "lighting_per_area": 1.1, + "rcr_threshold": null, + "lighting_per_person": null, + "additional_lighting_per_area": null, + "lighting_fraction_to_return_air": 0.0, + "lighting_fraction_radiant": 0.6, + "lighting_fraction_visible": 0.2, + "lighting_fraction_replaceable": 1.0, + "lpd_fraction_linear_fluorescent": 1.0, + "lpd_fraction_compact_fluorescent": null, + "lpd_fraction_high_bay": null, + "lpd_fraction_specialty_lighting": null, + "lpd_fraction_exit_lighting": null, + "lighting_schedule": "ApartmentHighRise LTG_OFF_SCH_2004_2007", + "compact_fluorescent_lighting_schedule": null, + "high_bay_lighting_schedule": null, + "specialty_lighting_schedule": null, + "exit_lighting_schedule": null, + "target_illuminance_setpoint": null, + "psa_nongeometry_fraction": null, + "ssa_nongeometry_fraction": null, + "notes": null, + "gas_equipment_per_area": null, + "gas_equipment_fraction_latent": null, + "gas_equipment_fraction_radiant": null, + "gas_equipment_fraction_lost": null, + "gas_equipment_schedule": null, + "electric_equipment_per_area": 0.6196632768, + "electric_equipment_fraction_latent": 0.0, + "electric_equipment_fraction_radiant": 0.5, + "electric_equipment_fraction_lost": 0.0, + "electric_equipment_schedule": "ApartmentHighRise EQP_OFF_SCH_2004_2007", + "additional_electric_equipment_schedule": null, + "additional_gas_equipment_schedule": null, + "occupancy_per_area": 2.11, + "occupancy_schedule": "ApartmentHighRise OCC_OFF_SCH", + "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", + "is_residential": null, + "ventilation_standard": "ASHRAE 62.1-1999", + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Bedrooms", + "ventilation_per_area": 0.1, + "ventilation_per_person": 0.0, + "ventilation_air_changes": null, + "minimum_total_air_changes": null, + "infiltration_per_exterior_area": 0.2016, + "infiltration_per_exterior_wall_area": null, + "infiltration_air_changes": null, + "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", + "infiltration_schedule_perimeter": null, + "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH", + "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH", + "service_water_heating_peak_flow_rate": null, + "service_water_heating_area": null, + "service_water_heating_peak_flow_per_area": "", + "service_water_heating_system_type": null, + "booster_water_heater_fraction": null, + "service_water_heating_target_temperature": null, + "booster_water_heating_target_temperature": null, + "service_water_heating_fraction_sensible": null, + "service_water_heating_fraction_latent": null, + "service_water_heating_schedule": null, + "exhaust_per_area": null, + "exhaust_fan_efficiency": null, + "exhaust_fan_power": null, + "exhaust_fan_pressure_rise": null, + "exhaust_fan_maximum_flow_rate": null, + "exhaust_availability_schedule": null, + "exhaust_flow_fraction_schedule": null, + "balanced_exhaust_fraction_schedule": null, + "manual_continuous_dimming": null, + "programmable_multilevel_dimming": null, + "multilevel_occupancy_sensors": null, + "occupancy_sensors": null, + "occupancy_sensors_with_personal_continuous_dimming": null, + "automatic_multilevel_switching_in_primary_sidelighted_areas": null, + "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, + "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, + "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, + "rgb": "120_230_199" + }, + { + "template": "90.1-2004", + "space_type": "Corridor", + "lighting_standard": "ASHRAE 90.1-2004", + "lighting_primary_space_type": "Corridor", + "lighting_secondary_space_type": "Corridor", + "lighting_per_area": 0.5, + "rcr_threshold": null, + "lighting_per_person": null, + "additional_lighting_per_area": null, + "lighting_fraction_to_return_air": 0.0, + "lighting_fraction_radiant": 0.6, + "lighting_fraction_visible": 0.2, + "lighting_fraction_replaceable": 1.0, + "lpd_fraction_linear_fluorescent": 1.0, + "lpd_fraction_compact_fluorescent": null, + "lpd_fraction_high_bay": null, + "lpd_fraction_specialty_lighting": null, + "lpd_fraction_exit_lighting": null, + "lighting_schedule": "ApartmentHighRise LTG_COR_SCH_2004_2007", + "compact_fluorescent_lighting_schedule": null, + "high_bay_lighting_schedule": null, + "specialty_lighting_schedule": null, + "exit_lighting_schedule": null, + "target_illuminance_setpoint": null, + "psa_nongeometry_fraction": null, + "ssa_nongeometry_fraction": null, + "notes": null, + "gas_equipment_per_area": null, + "gas_equipment_fraction_latent": null, + "gas_equipment_fraction_radiant": null, + "gas_equipment_fraction_lost": null, + "gas_equipment_schedule": null, + "electric_equipment_per_area": 0.0, + "electric_equipment_fraction_latent": 0.0, + "electric_equipment_fraction_radiant": 0.5, + "electric_equipment_fraction_lost": 0.0, + "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS", + "additional_electric_equipment_schedule": null, + "additional_gas_equipment_schedule": null, + "occupancy_per_area": 0.0, + "occupancy_schedule": "ApartmentMidRise All Off", + "occupancy_activity_schedule": null, + "is_residential": null, + "ventilation_standard": "ASHRAE 62.1-1999", + "ventilation_primary_space_type": "Public Spaces", + "ventilation_secondary_space_type": "Public restrooms", + "ventilation_per_area": 0.0, + "ventilation_per_person": 0.0, + "ventilation_air_changes": null, + "minimum_total_air_changes": null, + "infiltration_per_exterior_area": 0.2016, + "infiltration_per_exterior_wall_area": null, + "infiltration_air_changes": null, + "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", + "infiltration_schedule_perimeter": null, + "heating_setpoint_schedule": null, + "cooling_setpoint_schedule": null, + "service_water_heating_peak_flow_rate": null, + "service_water_heating_area": null, + "service_water_heating_peak_flow_per_area": "", + "service_water_heating_system_type": null, + "booster_water_heater_fraction": null, + "service_water_heating_target_temperature": null, + "booster_water_heating_target_temperature": null, + "service_water_heating_fraction_sensible": null, + "service_water_heating_fraction_latent": null, + "service_water_heating_schedule": null, + "exhaust_per_area": null, + "exhaust_fan_efficiency": null, + "exhaust_fan_power": null, + "exhaust_fan_pressure_rise": null, + "exhaust_fan_maximum_flow_rate": null, + "exhaust_availability_schedule": null, + "exhaust_flow_fraction_schedule": null, + "balanced_exhaust_fraction_schedule": null, + "manual_continuous_dimming": null, + "programmable_multilevel_dimming": null, + "multilevel_occupancy_sensors": null, + "occupancy_sensors": null, + "occupancy_sensors_with_personal_continuous_dimming": null, + "automatic_multilevel_switching_in_primary_sidelighted_areas": null, + "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, + "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, + "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, + "rgb": "169_31_31" + }, + { + "template": "90.1-2004", + "space_type": "Kitchen", + "lighting_standard": "ASHRAE 90.1-2004", + "lighting_primary_space_type": "Kitchen", + "lighting_secondary_space_type": "Kitchen", + "lighting_per_area": 1.2, + "rcr_threshold": null, + "lighting_per_person": null, + "additional_lighting_per_area": null, + "lighting_fraction_to_return_air": 0.0, + "lighting_fraction_radiant": 0.7, + "lighting_fraction_visible": 0.2, + "lighting_fraction_replaceable": 1.0, + "lpd_fraction_linear_fluorescent": 1.0, + "lpd_fraction_compact_fluorescent": null, + "lpd_fraction_high_bay": null, + "lpd_fraction_specialty_lighting": null, + "lpd_fraction_exit_lighting": null, + "lighting_schedule": "Hospital BLDG_LIGHT_SCH", + "compact_fluorescent_lighting_schedule": null, + "high_bay_lighting_schedule": null, + "specialty_lighting_schedule": null, + "exit_lighting_schedule": null, + "target_illuminance_setpoint": null, + "psa_nongeometry_fraction": null, + "ssa_nongeometry_fraction": null, + "notes": null, + "gas_equipment_per_area": 51.16, + "gas_equipment_fraction_latent": 0.0, + "gas_equipment_fraction_radiant": 0.5, + "gas_equipment_fraction_lost": 0.0, + "gas_equipment_schedule": "Hospital BLDG_EQUIP_SCH", + "electric_equipment_per_area": 7.5, + "electric_equipment_fraction_latent": 0.0, + "electric_equipment_fraction_radiant": 0.5, + "electric_equipment_fraction_lost": 0.0, + "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", + "additional_electric_equipment_schedule": null, + "additional_gas_equipment_schedule": null, + "occupancy_per_area": 5.0, + "occupancy_schedule": "Hospital BLDG_OCC_SCH", + "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", + "is_residential": null, + "ventilation_standard": "ASHRAE 62.1-1999", + "ventilation_primary_space_type": "Food and Beverage Service", + "ventilation_secondary_space_type": "Kitchens (cooking)", + "ventilation_per_area": 0.47, + "ventilation_per_person": 0.0, + "ventilation_air_changes": null, + "minimum_total_air_changes": null, + "infiltration_per_exterior_area": 0.0595, + "infiltration_per_exterior_wall_area": null, + "infiltration_air_changes": null, + "infiltration_schedule": "Hospital INFIL_SCH_PNNL", + "infiltration_schedule_perimeter": null, + "heating_setpoint_schedule": "Hospital HTGSETP_SCH", + "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", + "service_water_heating_peak_flow_rate": 150.0, + "service_water_heating_area": 10000.0, + "service_water_heating_peak_flow_per_area": 0.015, + "service_water_heating_system_type": "Dedicated", + "booster_water_heater_fraction": 0.6, + "service_water_heating_target_temperature": 140.0, + "booster_water_heating_target_temperature": 180.0, + "service_water_heating_fraction_sensible": 0.2, + "service_water_heating_fraction_latent": 0.05, + "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", + "exhaust_per_area": 0.7, + "exhaust_fan_efficiency": 0.338, + "exhaust_fan_power": 229133.6778, + "exhaust_fan_pressure_rise": 124.5, + "exhaust_fan_maximum_flow_rate": 7200.0, + "exhaust_availability_schedule": "Hospital Kitchen_Exhaust_SCH", + "exhaust_flow_fraction_schedule": "Hospital Kitchen_Exhaust_SCH", + "balanced_exhaust_fraction_schedule": "Hospital Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule", + "manual_continuous_dimming": null, + "programmable_multilevel_dimming": null, + "multilevel_occupancy_sensors": null, + "occupancy_sensors": null, + "occupancy_sensors_with_personal_continuous_dimming": null, + "automatic_multilevel_switching_in_primary_sidelighted_areas": null, + "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, + "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, + "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, + "rgb": "78_222_133" + }, + { + "template": "90.1-2004", + "space_type": "Lobby", + "lighting_standard": "ASHRAE 90.1-2004", + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "Lobby", + "lighting_per_area": 1.3, + "rcr_threshold": null, + "lighting_per_person": null, + "additional_lighting_per_area": null, + "lighting_fraction_to_return_air": 0.0, + "lighting_fraction_radiant": 0.7, + "lighting_fraction_visible": 0.2, + "lighting_fraction_replaceable": 1.0, + "lpd_fraction_linear_fluorescent": 1.0, + "lpd_fraction_compact_fluorescent": null, + "lpd_fraction_high_bay": null, + "lpd_fraction_specialty_lighting": null, + "lpd_fraction_exit_lighting": null, + "lighting_schedule": "Hospital BLDG_LIGHT_LOBBYFLR1_SCH", + "compact_fluorescent_lighting_schedule": null, + "high_bay_lighting_schedule": null, + "specialty_lighting_schedule": null, + "exit_lighting_schedule": null, + "target_illuminance_setpoint": null, + "psa_nongeometry_fraction": null, + "ssa_nongeometry_fraction": null, + "notes": null, + "gas_equipment_per_area": null, + "gas_equipment_fraction_latent": null, + "gas_equipment_fraction_radiant": null, + "gas_equipment_fraction_lost": null, + "gas_equipment_schedule": null, + "electric_equipment_per_area": 0.09999999999999999, + "electric_equipment_fraction_latent": 0.0, + "electric_equipment_fraction_radiant": 0.5, + "electric_equipment_fraction_lost": 0.0, + "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", + "additional_electric_equipment_schedule": null, + "additional_gas_equipment_schedule": null, + "occupancy_per_area": 1.333, + "occupancy_schedule": "Hospital BLDG_OCC_SCH", + "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", + "is_residential": null, + "ventilation_standard": "ASHRAE 62.1-1999", + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Lobbies", + "ventilation_per_area": 0.0, + "ventilation_per_person": 15.0, + "ventilation_air_changes": null, + "minimum_total_air_changes": null, + "infiltration_per_exterior_area": 0.0595, + "infiltration_per_exterior_wall_area": null, + "infiltration_air_changes": null, + "infiltration_schedule": "Hospital INFIL_SCH_PNNL", + "infiltration_schedule_perimeter": null, + "heating_setpoint_schedule": "Hospital HTGSETP_SCH", + "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", + "service_water_heating_peak_flow_rate": null, + "service_water_heating_area": null, + "service_water_heating_peak_flow_per_area": "", + "service_water_heating_system_type": null, + "booster_water_heater_fraction": null, + "service_water_heating_target_temperature": null, + "booster_water_heating_target_temperature": null, + "service_water_heating_fraction_sensible": null, + "service_water_heating_fraction_latent": null, + "service_water_heating_schedule": null, + "exhaust_per_area": null, + "exhaust_fan_efficiency": null, + "exhaust_fan_power": null, + "exhaust_fan_pressure_rise": null, + "exhaust_fan_maximum_flow_rate": null, + "exhaust_availability_schedule": null, + "exhaust_flow_fraction_schedule": null, + "balanced_exhaust_fraction_schedule": null, + "manual_continuous_dimming": null, + "programmable_multilevel_dimming": null, + "multilevel_occupancy_sensors": null, + "occupancy_sensors": null, + "occupancy_sensors_with_personal_continuous_dimming": null, + "automatic_multilevel_switching_in_primary_sidelighted_areas": null, + "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null, + "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null, + "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null, + "rgb": "31_162_169" + } + ] } \ No newline at end of file diff --git a/test/doe_prototype/test_medium_office.rb b/test/doe_prototype/test_medium_office.rb index dc0958a11e..808b81e81b 100644 --- a/test/doe_prototype/test_medium_office.rb +++ b/test/doe_prototype/test_medium_office.rb @@ -3,8 +3,8 @@ class TestMediumOffice < CreateDOEPrototypeBuildingTest building_types = ['MediumOffice'] - templates = ['DOE Ref Pre-1980','DOE Ref 1980-2004','90.1-2007','90.1-2013','90.1-2016','90.1-2019'] - climate_zones = ['ASHRAE 169-2013-2A','ASHRAE 169-2013-3B','ASHRAE 169-2013-5A','ASHRAE 169-2013-8A'] + templates = ['90.1-2004'] + climate_zones = ['ASHRAE 169-2013-4A'] epw_files = ['USA_FL_Miami.Intl.AP.722020_TMY3.epw'] # not used for ASHRAE/DOE archetypes, but required for call create_models = true run_models = false From 3b71a9f4b6848e87bd5549c67185cf82a57497b6 Mon Sep 17 00:00:00 2001 From: Weili Xu Date: Tue, 21 Mar 2023 11:11:53 -0700 Subject: [PATCH 02/45] remove jenkins and add github action --- .github/workflows/osstd-database.yml | 40 ++++++++++++++++++++++++++++ Jenkinsfile | 4 +-- Jenkinsfile_develop | 4 +-- 3 files changed, 44 insertions(+), 4 deletions(-) create mode 100644 .github/workflows/osstd-database.yml diff --git a/.github/workflows/osstd-database.yml b/.github/workflows/osstd-database.yml new file mode 100644 index 0000000000..66a48ad7b9 --- /dev/null +++ b/.github/workflows/osstd-database.yml @@ -0,0 +1,40 @@ +# This workflow will check formatting with Black, install Python dependencies, +# and run tests with pytest +on: + pull_request: + path: + - 'data/data-refactor' +jobs: + black-formatting-check: + name: Black formatting check + runs-on: 'ubuntu-latest' + steps: + - name: Checkout code + uses: actions/checkout@v3 + - name: Setup Python + uses: actions/setup-python@v4 + with: + python-version: '3.10' + # This will halt the action if formatting fails + # Note: This will also fail if there are syntax errors + - uses: psf/black@stable + with: + version: "22.12.0" + run-unit-tests: + name: Run unit tests + runs-on: 'ubuntu-latest' + steps: + - name: Checkout code + uses: actions/checkout@v3 + - name: Setup Python + uses: actions/setup-python@v4 + with: + python-version: '3.10' + cache: 'pipenv' + - name: Install pipenv + run: curl https://raw.githubusercontent.com/pypa/pipenv/master/get-pipenv.py | python + - name: Install dpendencies + run: pipenv install --dev + - name: Run pytests + # This will halt the action if any of the tests fail + run: pipenv run pytest -v \ No newline at end of file diff --git a/Jenkinsfile b/Jenkinsfile index 92372c5162..5c7b063d7f 100644 --- a/Jenkinsfile +++ b/Jenkinsfile @@ -1,5 +1,5 @@ //Jenkins pipelines are stored in shared libaries. Please see: https://github.com/tijcolem/nrel_cbci_jenkins_libs -@Library('cbci_shared_libs') _ +//@Library('cbci_shared_libs') _ -openstudio_standards() +//openstudio_standards() diff --git a/Jenkinsfile_develop b/Jenkinsfile_develop index a23fcd22bd..c9abbe3678 100644 --- a/Jenkinsfile_develop +++ b/Jenkinsfile_develop @@ -1,5 +1,5 @@ //Jenkins pipelines are stored in shared libaries. Please see: https://github.com/tijcolem/nrel_cbci_jenkins_libs -@Library('cbci_shared_libs') _ +//@Library('cbci_shared_libs') _ -openstudio_standards_develop() +//openstudio_standards_develop() From b10b44006ceb102f8163505bffa15a2e19b1c556 Mon Sep 17 00:00:00 2001 From: Weili Xu Date: Tue, 21 Mar 2023 11:13:43 -0700 Subject: [PATCH 03/45] fix bug --- .github/workflows/osstd-database.yml | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/.github/workflows/osstd-database.yml b/.github/workflows/osstd-database.yml index 66a48ad7b9..c89969fef1 100644 --- a/.github/workflows/osstd-database.yml +++ b/.github/workflows/osstd-database.yml @@ -13,8 +13,8 @@ jobs: uses: actions/checkout@v3 - name: Setup Python uses: actions/setup-python@v4 - with: - python-version: '3.10' + with: + python-version: '3.10' # This will halt the action if formatting fails # Note: This will also fail if there are syntax errors - uses: psf/black@stable From 8b631530f9a09a28a4dd20e5e35abd884ef35fa7 Mon Sep 17 00:00:00 2001 From: Weili Xu Date: Wed, 22 Mar 2023 16:00:48 -0700 Subject: [PATCH 04/45] Database code migration Database code migration --- .github/workflows/osstd-database.yml | 7 +- .gitignore | 33 + data/openstudio_standards_data/Pipfile | 14 + data/openstudio_standards_data/Pipfile.lock | 267 + data/openstudio_standards_data/README.md | 29 + .../applications/__init__.py | 0 .../create_openstudio_standards_json.py | 284 ++ .../applications/database_maintenance.py | 44 + .../applications/form/__init__.py | 0 .../applications/form/update_space_data.py | 158 + data/openstudio_standards_data/client.py | 55 + .../database_engine/__init__.py | 0 .../database_engine/assertions.py | 60 + .../database_engine/database.py | 159 + .../database_engine/database_util.py | 73 + .../database_tables/__init__.py | 83 + .../database_tables/envelope_requirement.py | 176 + .../hvac_minimum_requirement_boilers.py | 152 + .../hvac_minimum_requirement_boilers_90_1.py | 13 + .../hvac_minimum_requirement_chillers.py | 166 + .../hvac_minimum_requirement_chillers_90_1.py | 15 + .../hvac_minimum_requirement_furnaces.py | 124 + .../hvac_minimum_requirement_furnaces_90_1.py | 15 + ...c_minimum_requirement_heat_pump_cooling.py | 190 + ...imum_requirement_heat_pump_cooling_90_1.py | 17 + ...c_minimum_requirement_heat_pump_heating.py | 178 + ...imum_requirement_heat_pump_heating_90_1.py | 17 + ...hvac_minimum_requirement_heat_rejection.py | 107 + ...minimum_requirement_heat_rejection_90_1.py | 15 + .../hvac_minimum_requirement_motors.py | 118 + .../hvac_minimum_requirement_motors_90_1.py | 13 + ...um_requirement_unitary_air_conditioners.py | 197 + ...quirement_unitary_air_conditioners_90_1.py | 17 + .../hvac_minimum_requirement_water_heaters.py | 160 + ..._minimum_requirement_water_heaters_90_1.py | 15 + ...irement_water_source_heat_pumps_cooling.py | 128 + ...nt_water_source_heat_pumps_cooling_90_1.py | 17 + ...irement_water_source_heat_pumps_heating.py | 115 + ...nt_water_source_heat_pumps_heating_90_1.py | 17 + .../database_tables/level_1_space_types.py | 76 + .../level_2_electric_equipment.py | 95 + .../level_2_lighting_space_types.py | 69 + .../level_2_ventilation_space_types.py | 71 + .../level_3_lighting_90_1_2004.py | 13 + .../level_3_lighting_90_1_2019.py | 12 + .../level_3_lighting_90_1_definition.py | 90 + .../level_3_ventilation_62_1_2004.py | 13 + .../level_3_ventilation_62_1_2019.py | 12 + .../level_3_ventilation_62_1_definition.py | 112 + .../database_tables/support_constructions.py | 136 + ...electric_equipment_space_type_name_tags.py | 59 + .../support_lighting_space_type_name_tags.py | 57 + .../database_tables/support_materials.py | 251 + .../support_performance_curves.py | 212 + .../support_standard_templates.py | 74 + ...upport_ventilation_space_type_name_tags.py | 58 + .../system_requirement_economizer.py | 109 + .../system_requirement_economizer_90_1.py | 13 + .../system_requirement_energy_recovery.py | 166 + ...system_requirement_energy_recovery_90_1.py | 15 + .../initial_data/envelope_requirement.csv | 4534 +++++++++++++++++ .../general_building_space_type.json | 898 ++++ .../general_building_space_type_full.csv | 221 + .../hvac_minimum_requirement_boilers_90_1.csv | 22 + ...hvac_minimum_requirement_chillers_90_1.csv | 163 + ...hvac_minimum_requirement_furnaces_90_1.csv | 13 + ...mum_requirement_heat_pump_cooling_90_1.csv | 165 + ...mum_requirement_heat_pump_heating_90_1.csv | 51 + ...inimum_requirement_heat_rejection_90_1.csv | 31 + .../hvac_minimum_requirement_motors_90_1.csv | 148 + ...uirement_unitary_air_conditioners_90_1.csv | 196 + ...minimum_requirement_water_heaters_90_1.csv | 25 + ...t_water_source_heat_pumps_cooling_90_1.csv | 19 + ...t_water_source_heat_pumps_heating_90_1.csv | 7 + .../initial_data/level_1_space_types.csv | 129 + .../level_2_electric_equipment.csv | 91 + .../level_2_lighting_space_types.csv | 287 ++ .../level_2_ventilation_space_types.csv | 174 + .../level_3_lighting_90_1_2004.csv | 126 + .../level_3_lighting_90_1_2019.csv | 139 + .../level_3_ventilation_62_1_2004.csv | 64 + .../level_3_ventilation_62_1_2019.csv | 110 + .../initial_data/light_def_90_1_2004.json | 1127 ++++ .../initial_data/light_def_90_1_2019.json | 1244 +++++ .../initial_data/light_subspaces.json | 1718 +++++++ .../initial_data/lighting_space_tag.json | 476 ++ .../initial_data/plug_load_space_tag.json | 464 ++ .../initial_data/standard_template.json | 18 + .../initial_data/support_constructions.csv | 492 ++ ...lectric_equipment_space_type_name_tags.csv | 155 + .../support_lighting_space_type_name_tags.csv | 159 + .../initial_data/support_materials.csv | 1390 +++++ .../support_performance_curves.csv | 734 +++ .../support_standard_templates.csv | 3 + ...pport_ventilation_space_type_name_tags.csv | 111 + .../system_requirement_economizer_90_1.csv | 497 ++ ...ystem_requirement_energy_recovery_90_1.csv | 409 ++ .../initial_data/vent_def_62_1_2004.json | 884 ++++ .../initial_data/vent_def_62_1_2019.json | 1528 ++++++ .../initial_data/vent_space_tag.json | 332 ++ .../initial_data/vent_subspaces.json | 1040 ++++ .../query/__init__.py | 0 .../query/fetch/__init__.py | 0 .../query/fetch/database_table.py | 69 + .../query/fetch/space.py | 40 + .../query/fetch/template.py | 64 + .../query/update/__init__.py | 0 .../query/update/update_a_table.py | 28 + data/openstudio_standards_data/query/util.py | 54 + .../test/__init__.py | 0 .../test/test_database.py | 48 + .../test/test_template.py | 39 + 112 files changed, 25695 insertions(+), 2 deletions(-) create mode 100644 data/openstudio_standards_data/Pipfile create mode 100644 data/openstudio_standards_data/Pipfile.lock create mode 100644 data/openstudio_standards_data/README.md create mode 100644 data/openstudio_standards_data/applications/__init__.py create mode 100644 data/openstudio_standards_data/applications/create_openstudio_standards_json.py create mode 100644 data/openstudio_standards_data/applications/database_maintenance.py create mode 100644 data/openstudio_standards_data/applications/form/__init__.py create mode 100644 data/openstudio_standards_data/applications/form/update_space_data.py create mode 100644 data/openstudio_standards_data/client.py create mode 100644 data/openstudio_standards_data/database_engine/__init__.py create mode 100644 data/openstudio_standards_data/database_engine/assertions.py create mode 100644 data/openstudio_standards_data/database_engine/database.py create mode 100644 data/openstudio_standards_data/database_engine/database_util.py create mode 100644 data/openstudio_standards_data/database_tables/__init__.py create mode 100644 data/openstudio_standards_data/database_tables/envelope_requirement.py create mode 100644 data/openstudio_standards_data/database_tables/hvac_minimum_requirement_boilers.py create mode 100644 data/openstudio_standards_data/database_tables/hvac_minimum_requirement_boilers_90_1.py create mode 100644 data/openstudio_standards_data/database_tables/hvac_minimum_requirement_chillers.py create mode 100644 data/openstudio_standards_data/database_tables/hvac_minimum_requirement_chillers_90_1.py create mode 100644 data/openstudio_standards_data/database_tables/hvac_minimum_requirement_furnaces.py create mode 100644 data/openstudio_standards_data/database_tables/hvac_minimum_requirement_furnaces_90_1.py create mode 100644 data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_cooling.py create mode 100644 data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_cooling_90_1.py create mode 100644 data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_heating.py create mode 100644 data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_heating_90_1.py create mode 100644 data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_rejection.py create mode 100644 data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_rejection_90_1.py create mode 100644 data/openstudio_standards_data/database_tables/hvac_minimum_requirement_motors.py create mode 100644 data/openstudio_standards_data/database_tables/hvac_minimum_requirement_motors_90_1.py create mode 100644 data/openstudio_standards_data/database_tables/hvac_minimum_requirement_unitary_air_conditioners.py create mode 100644 data/openstudio_standards_data/database_tables/hvac_minimum_requirement_unitary_air_conditioners_90_1.py create mode 100644 data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_heaters.py create mode 100644 data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_heaters_90_1.py create mode 100644 data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_cooling.py create mode 100644 data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1.py create mode 100644 data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_heating.py create mode 100644 data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_heating_90_1.py create mode 100644 data/openstudio_standards_data/database_tables/level_1_space_types.py create mode 100644 data/openstudio_standards_data/database_tables/level_2_electric_equipment.py create mode 100644 data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py create mode 100644 data/openstudio_standards_data/database_tables/level_2_ventilation_space_types.py create mode 100644 data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2004.py create mode 100644 data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2019.py create mode 100644 data/openstudio_standards_data/database_tables/level_3_lighting_90_1_definition.py create mode 100644 data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2004.py create mode 100644 data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2019.py create mode 100644 data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_definition.py create mode 100644 data/openstudio_standards_data/database_tables/support_constructions.py create mode 100644 data/openstudio_standards_data/database_tables/support_electric_equipment_space_type_name_tags.py create mode 100644 data/openstudio_standards_data/database_tables/support_lighting_space_type_name_tags.py create mode 100644 data/openstudio_standards_data/database_tables/support_materials.py create mode 100644 data/openstudio_standards_data/database_tables/support_performance_curves.py create mode 100644 data/openstudio_standards_data/database_tables/support_standard_templates.py create mode 100644 data/openstudio_standards_data/database_tables/support_ventilation_space_type_name_tags.py create mode 100644 data/openstudio_standards_data/database_tables/system_requirement_economizer.py create mode 100644 data/openstudio_standards_data/database_tables/system_requirement_economizer_90_1.py create mode 100644 data/openstudio_standards_data/database_tables/system_requirement_energy_recovery.py create mode 100644 data/openstudio_standards_data/database_tables/system_requirement_energy_recovery_90_1.py create mode 100644 data/openstudio_standards_data/initial_data/envelope_requirement.csv create mode 100644 data/openstudio_standards_data/initial_data/general_building_space_type.json create mode 100644 data/openstudio_standards_data/initial_data/general_building_space_type_full.csv create mode 100644 data/openstudio_standards_data/initial_data/hvac_minimum_requirement_boilers_90_1.csv create mode 100644 data/openstudio_standards_data/initial_data/hvac_minimum_requirement_chillers_90_1.csv create mode 100644 data/openstudio_standards_data/initial_data/hvac_minimum_requirement_furnaces_90_1.csv create mode 100644 data/openstudio_standards_data/initial_data/hvac_minimum_requirement_heat_pump_cooling_90_1.csv create mode 100644 data/openstudio_standards_data/initial_data/hvac_minimum_requirement_heat_pump_heating_90_1.csv create mode 100644 data/openstudio_standards_data/initial_data/hvac_minimum_requirement_heat_rejection_90_1.csv create mode 100644 data/openstudio_standards_data/initial_data/hvac_minimum_requirement_motors_90_1.csv create mode 100644 data/openstudio_standards_data/initial_data/hvac_minimum_requirement_unitary_air_conditioners_90_1.csv create mode 100644 data/openstudio_standards_data/initial_data/hvac_minimum_requirement_water_heaters_90_1.csv create mode 100644 data/openstudio_standards_data/initial_data/hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1.csv create mode 100644 data/openstudio_standards_data/initial_data/hvac_minimum_requirement_water_source_heat_pumps_heating_90_1.csv create mode 100644 data/openstudio_standards_data/initial_data/level_1_space_types.csv create mode 100644 data/openstudio_standards_data/initial_data/level_2_electric_equipment.csv create mode 100644 data/openstudio_standards_data/initial_data/level_2_lighting_space_types.csv create mode 100644 data/openstudio_standards_data/initial_data/level_2_ventilation_space_types.csv create mode 100644 data/openstudio_standards_data/initial_data/level_3_lighting_90_1_2004.csv create mode 100644 data/openstudio_standards_data/initial_data/level_3_lighting_90_1_2019.csv create mode 100644 data/openstudio_standards_data/initial_data/level_3_ventilation_62_1_2004.csv create mode 100644 data/openstudio_standards_data/initial_data/level_3_ventilation_62_1_2019.csv create mode 100644 data/openstudio_standards_data/initial_data/light_def_90_1_2004.json create mode 100644 data/openstudio_standards_data/initial_data/light_def_90_1_2019.json create mode 100644 data/openstudio_standards_data/initial_data/light_subspaces.json create mode 100644 data/openstudio_standards_data/initial_data/lighting_space_tag.json create mode 100644 data/openstudio_standards_data/initial_data/plug_load_space_tag.json create mode 100644 data/openstudio_standards_data/initial_data/standard_template.json create mode 100644 data/openstudio_standards_data/initial_data/support_constructions.csv create mode 100644 data/openstudio_standards_data/initial_data/support_electric_equipment_space_type_name_tags.csv create mode 100644 data/openstudio_standards_data/initial_data/support_lighting_space_type_name_tags.csv create mode 100644 data/openstudio_standards_data/initial_data/support_materials.csv create mode 100644 data/openstudio_standards_data/initial_data/support_performance_curves.csv create mode 100644 data/openstudio_standards_data/initial_data/support_standard_templates.csv create mode 100644 data/openstudio_standards_data/initial_data/support_ventilation_space_type_name_tags.csv create mode 100644 data/openstudio_standards_data/initial_data/system_requirement_economizer_90_1.csv create mode 100644 data/openstudio_standards_data/initial_data/system_requirement_energy_recovery_90_1.csv create mode 100644 data/openstudio_standards_data/initial_data/vent_def_62_1_2004.json create mode 100644 data/openstudio_standards_data/initial_data/vent_def_62_1_2019.json create mode 100644 data/openstudio_standards_data/initial_data/vent_space_tag.json create mode 100644 data/openstudio_standards_data/initial_data/vent_subspaces.json create mode 100644 data/openstudio_standards_data/query/__init__.py create mode 100644 data/openstudio_standards_data/query/fetch/__init__.py create mode 100644 data/openstudio_standards_data/query/fetch/database_table.py create mode 100644 data/openstudio_standards_data/query/fetch/space.py create mode 100644 data/openstudio_standards_data/query/fetch/template.py create mode 100644 data/openstudio_standards_data/query/update/__init__.py create mode 100644 data/openstudio_standards_data/query/update/update_a_table.py create mode 100644 data/openstudio_standards_data/query/util.py create mode 100644 data/openstudio_standards_data/test/__init__.py create mode 100644 data/openstudio_standards_data/test/test_database.py create mode 100644 data/openstudio_standards_data/test/test_template.py diff --git a/.github/workflows/osstd-database.yml b/.github/workflows/osstd-database.yml index c89969fef1..a9e5037e57 100644 --- a/.github/workflows/osstd-database.yml +++ b/.github/workflows/osstd-database.yml @@ -3,7 +3,7 @@ on: pull_request: path: - - 'data/data-refactor' + - 'data/openstudio_standards_data' jobs: black-formatting-check: name: Black formatting check @@ -33,8 +33,11 @@ jobs: cache: 'pipenv' - name: Install pipenv run: curl https://raw.githubusercontent.com/pypa/pipenv/master/get-pipenv.py | python + working-directory: 'data/openstudio_standards_data' - name: Install dpendencies run: pipenv install --dev + working-directory: 'data/openstudio_standards_data' - name: Run pytests # This will halt the action if any of the tests fail - run: pipenv run pytest -v \ No newline at end of file + run: pipenv run pytest -v + working-directory: 'data/openstudio_standards_data' \ No newline at end of file diff --git a/.gitignore b/.gitignore index 71caa9db87..ed7a89e72d 100644 --- a/.gitignore +++ b/.gitignore @@ -41,3 +41,36 @@ coverage/ /data/standards/openstudio_standards_duplicates_log.csv /data/standards/export /data/geometry/../*.osw + +## Python ignores +# Byte-compiled / optimized / DLL files +__pycache__/ +*.py[cod] +*$py.class + +# C extensions +*.so + +# Distribution / packaging +.Python +build/ +develop-eggs/ +dist/ +downloads/ +eggs/ +.eggs/ +lib/ +lib64/ +parts/ +sdist/ +var/ +wheels/ +pip-wheel-metadata/ +share/python-wheels/ +*.egg-info/ +.installed.cfg +*.egg +MANIFEST + + + diff --git a/data/openstudio_standards_data/Pipfile b/data/openstudio_standards_data/Pipfile new file mode 100644 index 0000000000..61739bda50 --- /dev/null +++ b/data/openstudio_standards_data/Pipfile @@ -0,0 +1,14 @@ +[[source]] +url = "https://pypi.org/simple" +verify_ssl = true +name = "pypi" + +[packages] +pytest = "*" +black = "*" + +[dev-packages] +pytest-cov = "*" + +[requires] +python_version = "3.10" diff --git a/data/openstudio_standards_data/Pipfile.lock b/data/openstudio_standards_data/Pipfile.lock new file mode 100644 index 0000000000..b409a88def --- /dev/null +++ b/data/openstudio_standards_data/Pipfile.lock @@ -0,0 +1,267 @@ +{ + "_meta": { + "hash": { + "sha256": "8ce59fe81cf863b2197b2f755c3c40c7544bce0aed72fcf72933595a7de8e9a4" + }, + "pipfile-spec": 6, + "requires": { + "python_version": "3.10" + }, + "sources": [ + { + "name": "pypi", + "url": "https://pypi.org/simple", + "verify_ssl": true + } + ] + }, + "default": { + "attrs": { + "hashes": [ + "sha256:29e95c7f6778868dbd49170f98f8818f78f3dc5e0e37c0b1f474e3561b240836", + "sha256:c9227bfc2f01993c03f68db37d1d15c9690188323c067c641f1a35ca58185f99" + ], + "markers": "python_version >= '3.6'", + "version": "==22.2.0" + }, + "black": { + "hashes": [ + "sha256:101c69b23df9b44247bd88e1d7e90154336ac4992502d4197bdac35dd7ee3320", + "sha256:159a46a4947f73387b4d83e87ea006dbb2337eab6c879620a3ba52699b1f4351", + "sha256:1f58cbe16dfe8c12b7434e50ff889fa479072096d79f0a7f25e4ab8e94cd8350", + "sha256:229351e5a18ca30f447bf724d007f890f97e13af070bb6ad4c0a441cd7596a2f", + "sha256:436cc9167dd28040ad90d3b404aec22cedf24a6e4d7de221bec2730ec0c97bcf", + "sha256:559c7a1ba9a006226f09e4916060982fd27334ae1998e7a38b3f33a37f7a2148", + "sha256:7412e75863aa5c5411886804678b7d083c7c28421210180d67dfd8cf1221e1f4", + "sha256:77d86c9f3db9b1bf6761244bc0b3572a546f5fe37917a044e02f3166d5aafa7d", + "sha256:82d9fe8fee3401e02e79767016b4907820a7dc28d70d137eb397b92ef3cc5bfc", + "sha256:9eedd20838bd5d75b80c9f5487dbcb06836a43833a37846cf1d8c1cc01cef59d", + "sha256:c116eed0efb9ff870ded8b62fe9f28dd61ef6e9ddd28d83d7d264a38417dcee2", + "sha256:d30b212bffeb1e252b31dd269dfae69dd17e06d92b87ad26e23890f3efea366f" + ], + "index": "pypi", + "version": "==22.12.0" + }, + "click": { + "hashes": [ + "sha256:7682dc8afb30297001674575ea00d1814d808d6a36af415a82bd481d37ba7b8e", + "sha256:bb4d8133cb15a609f44e8213d9b391b0809795062913b383c62be0ee95b1db48" + ], + "markers": "python_version >= '3.7'", + "version": "==8.1.3" + }, + "colorama": { + "hashes": [ + "sha256:08695f5cb7ed6e0531a20572697297273c47b8cae5a63ffc6d6ed5c201be6e44", + "sha256:4f1d9991f5acc0ca119f9d443620b77f9d6b33703e51011c16baf57afb285fc6" + ], + "markers": "sys_platform == 'win32'", + "version": "==0.4.6" + }, + "exceptiongroup": { + "hashes": [ + "sha256:327cbda3da756e2de031a3107b81ab7b3770a602c4d16ca618298c526f4bec1e", + "sha256:bcb67d800a4497e1b404c2dd44fca47d3b7a5e5433dbab67f96c1a685cdfdf23" + ], + "markers": "python_version < '3.11'", + "version": "==1.1.0" + }, + "iniconfig": { + "hashes": [ + "sha256:2d91e135bf72d31a410b17c16da610a82cb55f6b0477d1a902134b24a455b8b3", + "sha256:b6a85871a79d2e3b22d2d1b94ac2824226a63c6b741c88f7ae975f18b6778374" + ], + "markers": "python_version >= '3.7'", + "version": "==2.0.0" + }, + "mypy-extensions": { + "hashes": [ + "sha256:090fedd75945a69ae91ce1303b5824f428daf5a028d2f6ab8a299250a846f15d", + "sha256:2d82818f5bb3e369420cb3c4060a7970edba416647068eb4c5343488a6c604a8" + ], + "version": "==0.4.3" + }, + "packaging": { + "hashes": [ + "sha256:714ac14496c3e68c99c29b00845f7a2b85f3bb6f1078fd9f72fd20f0570002b2", + "sha256:b6ad297f8907de0fa2fe1ccbd26fdaf387f5f47c7275fedf8cce89f99446cf97" + ], + "markers": "python_version >= '3.7'", + "version": "==23.0" + }, + "pathspec": { + "hashes": [ + "sha256:3c95343af8b756205e2aba76e843ba9520a24dd84f68c22b9f93251507509dd6", + "sha256:56200de4077d9d0791465aa9095a01d421861e405b5096955051deefd697d6f6" + ], + "markers": "python_version >= '3.7'", + "version": "==0.10.3" + }, + "platformdirs": { + "hashes": [ + "sha256:83c8f6d04389165de7c9b6f0c682439697887bca0aa2f1c87ef1826be3584490", + "sha256:e1fea1fe471b9ff8332e229df3cb7de4f53eeea4998d3b6bfff542115e998bd2" + ], + "markers": "python_version >= '3.7'", + "version": "==2.6.2" + }, + "pluggy": { + "hashes": [ + "sha256:4224373bacce55f955a878bf9cfa763c1e360858e330072059e10bad68531159", + "sha256:74134bbf457f031a36d68416e1509f34bd5ccc019f0bcc952c7b909d06b37bd3" + ], + "markers": "python_version >= '3.6'", + "version": "==1.0.0" + }, + "pytest": { + "hashes": [ + "sha256:c7c6ca206e93355074ae32f7403e8ea12163b1163c976fee7d4d84027c162be5", + "sha256:d45e0952f3727241918b8fd0f376f5ff6b301cc0777c6f9a556935c92d8a7d42" + ], + "index": "pypi", + "version": "==7.2.1" + }, + "tomli": { + "hashes": [ + "sha256:939de3e7a6161af0c887ef91b7d41a53e7c5a1ca976325f429cb46ea9bc30ecc", + "sha256:de526c12914f0c550d15924c62d72abc48d6fe7364aa87328337a31007fe8a4f" + ], + "markers": "python_full_version < '3.11.0a7'", + "version": "==2.0.1" + } + }, + "develop": { + "attrs": { + "hashes": [ + "sha256:29e95c7f6778868dbd49170f98f8818f78f3dc5e0e37c0b1f474e3561b240836", + "sha256:c9227bfc2f01993c03f68db37d1d15c9690188323c067c641f1a35ca58185f99" + ], + "markers": "python_version >= '3.6'", + "version": "==22.2.0" + }, + "colorama": { + "hashes": [ + "sha256:08695f5cb7ed6e0531a20572697297273c47b8cae5a63ffc6d6ed5c201be6e44", + "sha256:4f1d9991f5acc0ca119f9d443620b77f9d6b33703e51011c16baf57afb285fc6" + ], + "markers": "sys_platform == 'win32'", + "version": "==0.4.6" + }, + "coverage": { + "extras": [ + "toml" + ], + "hashes": [ + "sha256:051afcbd6d2ac39298d62d340f94dbb6a1f31de06dfaf6fcef7b759dd3860c45", + "sha256:0a1890fca2962c4f1ad16551d660b46ea77291fba2cc21c024cd527b9d9c8809", + "sha256:0ee30375b409d9a7ea0f30c50645d436b6f5dfee254edffd27e45a980ad2c7f4", + "sha256:13250b1f0bd023e0c9f11838bdeb60214dd5b6aaf8e8d2f110c7e232a1bff83b", + "sha256:17e01dd8666c445025c29684d4aabf5a90dc6ef1ab25328aa52bedaa95b65ad7", + "sha256:19245c249aa711d954623d94f23cc94c0fd65865661f20b7781210cb97c471c0", + "sha256:1caed2367b32cc80a2b7f58a9f46658218a19c6cfe5bc234021966dc3daa01f0", + "sha256:1f66862d3a41674ebd8d1a7b6f5387fe5ce353f8719040a986551a545d7d83ea", + "sha256:220e3fa77d14c8a507b2d951e463b57a1f7810a6443a26f9b7591ef39047b1b2", + "sha256:276f4cd0001cd83b00817c8db76730938b1ee40f4993b6a905f40a7278103b3a", + "sha256:29de916ba1099ba2aab76aca101580006adfac5646de9b7c010a0f13867cba45", + "sha256:2a7f23bbaeb2a87f90f607730b45564076d870f1fb07b9318d0c21f36871932b", + "sha256:2c407b1950b2d2ffa091f4e225ca19a66a9bd81222f27c56bd12658fc5ca1209", + "sha256:30b5fec1d34cc932c1bc04017b538ce16bf84e239378b8f75220478645d11fca", + "sha256:3c2155943896ac78b9b0fd910fb381186d0c345911f5333ee46ac44c8f0e43ab", + "sha256:411d4ff9d041be08fdfc02adf62e89c735b9468f6d8f6427f8a14b6bb0a85095", + "sha256:436e103950d05b7d7f55e39beeb4d5be298ca3e119e0589c0227e6d0b01ee8c7", + "sha256:49640bda9bda35b057b0e65b7c43ba706fa2335c9a9896652aebe0fa399e80e6", + "sha256:4a950f83fd3f9bca23b77442f3a2b2ea4ac900944d8af9993743774c4fdc57af", + "sha256:50a6adc2be8edd7ee67d1abc3cd20678987c7b9d79cd265de55941e3d0d56499", + "sha256:52ab14b9e09ce052237dfe12d6892dd39b0401690856bcfe75d5baba4bfe2831", + "sha256:54f7e9705e14b2c9f6abdeb127c390f679f6dbe64ba732788d3015f7f76ef637", + "sha256:66e50680e888840c0995f2ad766e726ce71ca682e3c5f4eee82272c7671d38a2", + "sha256:790e4433962c9f454e213b21b0fd4b42310ade9c077e8edcb5113db0818450cb", + "sha256:7a38362528a9115a4e276e65eeabf67dcfaf57698e17ae388599568a78dcb029", + "sha256:7b05ed4b35bf6ee790832f68932baf1f00caa32283d66cc4d455c9e9d115aafc", + "sha256:7e109f1c9a3ece676597831874126555997c48f62bddbcace6ed17be3e372de8", + "sha256:949844af60ee96a376aac1ded2a27e134b8c8d35cc006a52903fc06c24a3296f", + "sha256:95304068686545aa368b35dfda1cdfbbdbe2f6fe43de4a2e9baa8ebd71be46e2", + "sha256:9e662e6fc4f513b79da5d10a23edd2b87685815b337b1a30cd11307a6679148d", + "sha256:a9fed35ca8c6e946e877893bbac022e8563b94404a605af1d1e6accc7eb73289", + "sha256:b69522b168a6b64edf0c33ba53eac491c0a8f5cc94fa4337f9c6f4c8f2f5296c", + "sha256:b78729038abea6a5df0d2708dce21e82073463b2d79d10884d7d591e0f385ded", + "sha256:b8c56bec53d6e3154eaff6ea941226e7bd7cc0d99f9b3756c2520fc7a94e6d96", + "sha256:b9727ac4f5cf2cbf87880a63870b5b9730a8ae3a4a360241a0fdaa2f71240ff0", + "sha256:ba3027deb7abf02859aca49c865ece538aee56dcb4871b4cced23ba4d5088904", + "sha256:be9fcf32c010da0ba40bf4ee01889d6c737658f4ddff160bd7eb9cac8f094b21", + "sha256:c18d47f314b950dbf24a41787ced1474e01ca816011925976d90a88b27c22b89", + "sha256:c76a3075e96b9c9ff00df8b5f7f560f5634dffd1658bafb79eb2682867e94f78", + "sha256:cbfcba14a3225b055a28b3199c3d81cd0ab37d2353ffd7f6fd64844cebab31ad", + "sha256:d254666d29540a72d17cc0175746cfb03d5123db33e67d1020e42dae611dc196", + "sha256:d66187792bfe56f8c18ba986a0e4ae44856b1c645336bd2c776e3386da91e1dd", + "sha256:d8d04e755934195bdc1db45ba9e040b8d20d046d04d6d77e71b3b34a8cc002d0", + "sha256:d8f3e2e0a1d6777e58e834fd5a04657f66affa615dae61dd67c35d1568c38882", + "sha256:e057e74e53db78122a3979f908973e171909a58ac20df05c33998d52e6d35757", + "sha256:e4ce984133b888cc3a46867c8b4372c7dee9cee300335e2925e197bcd45b9e16", + "sha256:ea76dbcad0b7b0deb265d8c36e0801abcddf6cc1395940a24e3595288b405ca0", + "sha256:ecb0f73954892f98611e183f50acdc9e21a4653f294dfbe079da73c6378a6f47", + "sha256:ef14d75d86f104f03dea66c13188487151760ef25dd6b2dbd541885185f05f40", + "sha256:f26648e1b3b03b6022b48a9b910d0ae209e2d51f50441db5dce5b530fad6d9b1", + "sha256:f67472c09a0c7486e27f3275f617c964d25e35727af952869dd496b9b5b7f6a3" + ], + "markers": "python_version >= '3.7'", + "version": "==7.0.5" + }, + "exceptiongroup": { + "hashes": [ + "sha256:327cbda3da756e2de031a3107b81ab7b3770a602c4d16ca618298c526f4bec1e", + "sha256:bcb67d800a4497e1b404c2dd44fca47d3b7a5e5433dbab67f96c1a685cdfdf23" + ], + "markers": "python_version < '3.11'", + "version": "==1.1.0" + }, + "iniconfig": { + "hashes": [ + "sha256:2d91e135bf72d31a410b17c16da610a82cb55f6b0477d1a902134b24a455b8b3", + "sha256:b6a85871a79d2e3b22d2d1b94ac2824226a63c6b741c88f7ae975f18b6778374" + ], + "markers": "python_version >= '3.7'", + "version": "==2.0.0" + }, + "packaging": { + "hashes": [ + "sha256:714ac14496c3e68c99c29b00845f7a2b85f3bb6f1078fd9f72fd20f0570002b2", + "sha256:b6ad297f8907de0fa2fe1ccbd26fdaf387f5f47c7275fedf8cce89f99446cf97" + ], + "markers": "python_version >= '3.7'", + "version": "==23.0" + }, + "pluggy": { + "hashes": [ + "sha256:4224373bacce55f955a878bf9cfa763c1e360858e330072059e10bad68531159", + "sha256:74134bbf457f031a36d68416e1509f34bd5ccc019f0bcc952c7b909d06b37bd3" + ], + "markers": "python_version >= '3.6'", + "version": "==1.0.0" + }, + "pytest": { + "hashes": [ + "sha256:c7c6ca206e93355074ae32f7403e8ea12163b1163c976fee7d4d84027c162be5", + "sha256:d45e0952f3727241918b8fd0f376f5ff6b301cc0777c6f9a556935c92d8a7d42" + ], + "index": "pypi", + "version": "==7.2.1" + }, + "pytest-cov": { + "hashes": [ + "sha256:2feb1b751d66a8bd934e5edfa2e961d11309dc37b73b0eabe73b5945fee20f6b", + "sha256:996b79efde6433cdbd0088872dbc5fb3ed7fe1578b68cdbba634f14bb8dd0470" + ], + "index": "pypi", + "version": "==4.0.0" + }, + "tomli": { + "hashes": [ + "sha256:939de3e7a6161af0c887ef91b7d41a53e7c5a1ca976325f429cb46ea9bc30ecc", + "sha256:de526c12914f0c550d15924c62d72abc48d6fe7364aa87328337a31007fe8a4f" + ], + "markers": "python_full_version < '3.11.0a7'", + "version": "==2.0.1" + } + } +} diff --git a/data/openstudio_standards_data/README.md b/data/openstudio_standards_data/README.md new file mode 100644 index 0000000000..8d1ba130ca --- /dev/null +++ b/data/openstudio_standards_data/README.md @@ -0,0 +1,29 @@ +## Data Refactor Repo + +### Prerequisite +Python 3.10 (3.9 could work but not tested) + +### How to use +Clone this repo +To create the full database in your local repo: + +```python +import sqlite3 +from applications.database_maintenance import create_openstudio_standards_database_from_csv + +conn = sqlite3.connect('openstudio_standards.db') +create_openstudio_standards_database(conn) +conn.close() + +``` + +This code will generate an `openstudio_standards_database.sql` in the same file directory. + + +### How to contribute: +1. Create a new branch +2. Write code +3. Run `pipenv run black .` -> format your code +4. Run `pipenv run pytest` -> make sure all unit test is passed (NOTE: you must run pytest under data-refactor folder) + +Push your changes. diff --git a/data/openstudio_standards_data/applications/__init__.py b/data/openstudio_standards_data/applications/__init__.py new file mode 100644 index 0000000000..e69de29bb2 diff --git a/data/openstudio_standards_data/applications/create_openstudio_standards_json.py b/data/openstudio_standards_data/applications/create_openstudio_standards_json.py new file mode 100644 index 0000000000..bd24ceeb56 --- /dev/null +++ b/data/openstudio_standards_data/applications/create_openstudio_standards_json.py @@ -0,0 +1,284 @@ +import json +import sqlite3 +import logging + +from database_tables.level_2_electric_equipment import ( + RECORD_TEMPLATE as plug_load_record_template, +) +from query.fetch.space import fetch_space_data +from query.fetch.database_table import ( + fetch_table, + fetch_records_from_table_by_key_values, +) +from query.fetch.template import fetch_templates + + +def create_osstd_space_data_json(conn: sqlite3.Connection, json_data_dir: str): + """ + Extract osstd building data to a json file. + :param conn: database connection + :param json_data_dir: directory + :return: + """ + space_data = [] + + # Step 1, we need to get the template table and loop in the table + standard_templates = fetch_templates(conn) + # Step 2, get all building -> light and vent map table + space_map_table = fetch_space_data(conn) + # Step 3, create an empty data holder to serve a memoize storage for standard tables + standard_data_tables = dict() + + for template in standard_templates: + lighting_standard_table = template["lighting_standard_table"] + ventilation_standard_table = template["ventilation_standard_table"] + # filter out the matching lighting standard table and ventilation standard table + subset_space_map_table = filter( + lambda bldg: bldg["level_3_lighting_definition_table"] + == lighting_standard_table + and bldg["level_3_ventilation_definition_table"] + == ventilation_standard_table, + space_map_table, + ) + for space in subset_space_map_table: + # WX: I tried to avoid having queries inside the loop but this seems to be a decision to make either loop + # the queries or pre-query each standard version tables outside the loop but increase the maintenance effort + sp_data = dict() + sp_data["template"] = template["template"] + sp_data["lighting_standard"] = template["lighting_standard"] + sp_data["ventilation_standard"] = template["ventilation_standard"] + sp_data["space_type"] = space["space_type"] + + lpd_id = int(space["level_3_lighting_defintion_id"]) + vent_id = int(space["level_3_ventilation_defintion_id"]) + if lighting_standard_table not in standard_data_tables.keys(): + light_table = fetch_table(conn, lighting_standard_table) + standard_data_tables[lighting_standard_table] = light_table + if ventilation_standard_table not in standard_data_tables.keys(): + vent_table = fetch_table(conn, ventilation_standard_table) + standard_data_tables[ventilation_standard_table] = vent_table + if space.get("electric_equipment_space_type_name"): + plug_load_record = fetch_records_from_table_by_key_values( + conn, + "equip_load", + { + "electric_equipment_space_type_name": space[ + "electric_equipment_space_type_name" + ] + }, + ) + if plug_load_record: + # Get the first record in the list. + plug_load_record = plug_load_record[0] + else: + plug_load_record = plug_load_record_template + light = next( + ltg + for ltg in standard_data_tables[lighting_standard_table] + if ltg["id"] == lpd_id + ) + vent = next( + vt + for vt in standard_data_tables[ventilation_standard_table] + if vt["id"] == vent_id + ) + sp_data.update(light) + sp_data.update(vent) + sp_data.update(plug_load_record) + # delete ID parameter, the ID is database specific and does not need + # included in the json + sp_data.pop("id", None) + + space_data.append(sp_data) + + with open(json_data_dir, "w") as output_report: + output_report.write(json.dumps(space_data, indent=4)) + + +def create_openstudio_standards_data_json_ashrae_90_1( + conn: sqlite3.Connection, version_90_1: str +) -> None: + """ + Create and export data for a specific version of ASHRAE 90.1 to be used by OpenStudio Standards + + :param conn (sqlite3.Connection): database connection + :param version_90_1 (str): code version of ASHRAE 90.1, e.g. "2004", "2007", etc. + """ + # Dictionary that maps OpenStudio Standards JSON data file names to database table(s) + # The mapping defined here covers data that varies based on code version + tables_to_export_90_1 = { + "chillers": ["hvac_minimum_requirement_chillers_90_1"], + "boilers": ["hvac_minimum_requirement_boilers_90_1"], + "furnaces": ["hvac_minimum_requirement_furnaces_90_1"], + "heat_rejection": ["hvac_minimum_requirement_heat_rejection_90_1"], + "motors": ["hvac_minimum_requirement_motors_90_1"], + "unitary_acs": ["hvac_minimum_requirement_unitary_air_conditioners_90_1"], + "water_source_heat_pumps_heating": [ + "hvac_minimum_requirement_water_source_heat_pumps_heating_90_1" + ], + "water_source_heat_pumps": [ + "hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1" + ], + "water_heaters": ["hvac_minimum_requirement_water_heaters_90_1"], + "heat_pumps": ["hvac_minimum_requirement_heat_pump_cooling_90_1"], + "heat_pumps_heating": ["hvac_minimum_requirement_heat_pump_heating_90_1"], + "economizers": ["system_requirement_economizer_90_1"], + "energy_recovery": ["system_requirement_energy_recovery_90_1"], + "construction_properties": ["envelope_requirement"], + } + + # Generate and "export" the data to the correct location within the OpenStudio Standards repository + create_openstudio_standards_code_version_data_json( + conn, + code="ashrae_90_1", + code_version=version_90_1, + template=f"90.1-{version_90_1}", + tables_to_export=tables_to_export_90_1, + ) + + # The mapping defined here covers data that does NOT vary based on code version + tables_to_export_90_1 = { + "materials": "support_materials", + "constructions": "support_constructions", + "curves": "support_performance_curves", + } + + # Generate and "export" the data to the correct location within the OpenStudio Standards repository + create_openstudio_standards_code_data_json( + conn, code="ashrae_90_1", tables_to_export=tables_to_export_90_1 + ) + + +def create_openstudio_standards_code_version_data_json( + conn: sqlite3.Connection, + code: str, + code_version: str, + template: str, + tables_to_export: dict, +) -> None: + """ + Extract code- and code version-specific OpenStudio Standards data from the database and export it to JSON files + :param conn (sqlite3.Connection): database connection + :param code (str): name of the building energy code, e.g. "ashrae_90_1" + :param code_version (str): verion of the code, e.g. "2004", "2007", etc. + :param template (str): template corresponding to the code and code version, e.g. "90.1-2004", or "90.1-2007" + :param tables_to_export (dict): mapping of name of OpenStudio Standards JSON file name to corresponding tables from the database that contains the data for the code and code version data + """ + for table_type, tables in tables_to_export.items(): + logging.info(f"Creating {table_type} data") + + # Store the retrieved content from the database + file_content = {f"{table_type}": []} + + # Iterate through the database tables to retrieve necessary tables + for table in tables: + logging.info(f"Processing data in {table} table") + + # Get data + records = fetch_records_from_table_by_key_values( + conn, table, {"template": template} + ) + logging.info(f"{len(records)} found") + + # Process/clean retrieved data + if len(records) > 0: + file_content[table_type].extend(process_records(records)) + + # Export retrieved data + if len(file_content[table_type]) > 0: + with open( + f"../../lib/openstudio-standards/standards/{code}/{code}_{code_version}/data/{code}_{code_version}.{table_type}.json", + "w+", + ) as output_report: + output_report.write(json.dumps(file_content, indent=2)) + else: + logging.warning( + f"No records were found, so {table} won't be created for {code} {code_version}" + ) + + +def create_openstudio_standards_code_data_json( + conn: sqlite3.Connection, code: str, tables_to_export: dict +) -> None: + """ + Extract code version-specific OpenStudio Standards data from the database and export it to JSON files + :param conn (sqlite3.Connection): database connection + :param code (str): name of the building energy code, e.g. "ashrae_90_1" + :param tables_to_export (dict): mapping of name of OpenStudio Standards JSON file name to corresponding tables from the database that contains the data for the code and code version data + """ + for table_type, table in tables_to_export.items(): + # Store the retrieved content from the database + file_content = {f"{table_type}": []} + + logging.info(f"Processing data in {table} table") + + # Get data + records = fetch_table(conn, table) + logging.info(f"{len(records)} found") + + # Process/clean retrieved data + if len(records) > 0: + file_content[table_type].extend(process_records(records)) + + # Export retrieved data + if len(file_content[table_type]) > 0: + with open( + f"../../lib/openstudio-standards/standards/{code}/data/{code}.{table_type}.json", + "w+", + ) as output_report: + output_report.write(json.dumps(file_content, indent=2)) + else: + logging.warning( + f"No records were found, so {table} won't be created for {code}" + ) + + +def process_records(records: list) -> list: + """Process/clean the data retrieved from the database to match the format expected by OpenStudio Standards + :param records (list): record(s) retrieved from the database that require processing/cleaning to match the expected format + :returns list: processed/cleaned records + """ + # Sort records by IDs (if exists in the data) to ensure consistent ordering of the exported data + if "id" in list(records[0].keys()): + records = sorted(records, key=lambda d: d["id"]) + + # Iterate through the records to perform key/value pair modifications + for record in records: + # Remove unnecessary key/value pairs + for key in ["template", "id", "annotation"]: + if key in list(record.keys()): + del record[key] + + materials = [] + for key, value in record.items(): + # Reformat date + if "_date" in key: + # '9/9/1919' + date = value.split("/") + year = date[2] if len(date[2]) > 1 else f"0{date[2]}" + month = date[0] if len(date[0]) > 1 else f"0{date[0]}" + day = date[1] if len(date[1]) > 1 else f"0{date[1]}" + record[key] = f"{year}-{month}-{day}T00:00:00+00:00" + + # Convert string booleans to actual booleans + if value == "TRUE": + record[key] = True + if value == "FALSE": + record[key] = False + + # Identify of the data is part of an "enumeration" of material + # e.g., is the key "material_1", or "material_2", etc. + material_id = key.split("material_")[-1] + try: + material_id = int(material_id) + except: + pass + if isinstance(material_id, int) and not value is None: + materials.append(value) + + # Create a list of materials instead of having multiple material key/value pairs + if len(materials) > 0: + for i in range(1, 7): + del record[f"material_{i}"] + record["materials"] = materials + return records diff --git a/data/openstudio_standards_data/applications/database_maintenance.py b/data/openstudio_standards_data/applications/database_maintenance.py new file mode 100644 index 0000000000..f90d2de09c --- /dev/null +++ b/data/openstudio_standards_data/applications/database_maintenance.py @@ -0,0 +1,44 @@ +import sqlite3 + +import database_tables as tables +from database_engine.database_util import read_csv_to_list_dict, read_json_to_list_dict + + +def create_openstudio_standards_database_from_csv(conn: sqlite3.Connection): + database_available_tables = tables.__gettables__() + table_list = [table[1]() for table in database_available_tables] + with conn: + for datatable in table_list: + datatable.create_a_table(conn) + data = read_csv_to_list_dict(f"{datatable.initial_data_directory}.csv") + for record in data: + print(record) + print(datatable.add_a_record(conn, record)) + + +def create_openstudio_standards_database_from_json(conn: sqlite3.Connection): + database_available_tables = tables.__gettables__() + table_list = [table[1]() for table in database_available_tables] + with conn: + for datatable in table_list: + datatable.create_a_table(conn) + data = read_json_to_list_dict(f"{datatable.initial_data_directory}.json") + for record in data: + print(record) + print(datatable.add_a_record(conn, record)) + + +def export_openstudio_standards_database_to_csv(conn: sqlite3.Connection, save_dir=""): + database_available_tables = tables.__gettables__() + table_list = [table[1]() for table in database_available_tables] + with conn: + for datatable in table_list: + datatable.export_table_to_csv(conn, save_dir) + + +def export_openstudio_standards_database_to_json(conn: sqlite3.Connection, save_dir=""): + database_available_tables = tables.__gettables__() + table_list = [table[1]() for table in database_available_tables] + with conn: + for datatable in table_list: + datatable.export_table_to_json(conn, save_dir) diff --git a/data/openstudio_standards_data/applications/form/__init__.py b/data/openstudio_standards_data/applications/form/__init__.py new file mode 100644 index 0000000000..e69de29bb2 diff --git a/data/openstudio_standards_data/applications/form/update_space_data.py b/data/openstudio_standards_data/applications/form/update_space_data.py new file mode 100644 index 0000000000..5b92ad8545 --- /dev/null +++ b/data/openstudio_standards_data/applications/form/update_space_data.py @@ -0,0 +1,158 @@ +import sqlite3 + +from database_engine.assertions import getattr_ +from database_tables.level_2_electric_equipment import EquipLoadTable +from query.fetch.database_table import fetch_records_from_table_by_key_values +from query.fetch.template import fetch_template_data_by_template_first +from database_tables.level_1_space_types import ( + TABLE_NAME as GENERAL_SPACE_TYPE_TABLE_NAME, +) +from database_tables.level_2_lighting_space_types import ( + TABLE_NAME as LIGHT_SUBSPACES_TABLE_NAME, +) +from database_tables.level_2_ventilation_space_types import ( + TABLE_NAME as VENT_SUBSPACES_TABLE_NAME, +) +from query.update.update_a_table import update_a_table +import database_tables as tables +from query.util import match_dict_data_by_key + +SPACE_TABLE_HEADER = [ + "space_type", + "level_3_lighting_defintion_id", + "level_3_ventilation_defintion_id", +] + +FETCH_SPACE_TO_TABLE_QUEYR = f""" +SELECT {','.join(SPACE_TABLE_HEADER)} FROM {GENERAL_SPACE_TYPE_TABLE_NAME} + LEFT JOIN {LIGHT_SUBSPACES_TABLE_NAME} ON {GENERAL_SPACE_TYPE_TABLE_NAME}.lighting_space_type_name = {LIGHT_SUBSPACES_TABLE_NAME}.lighting_space_type_name + LEFT JOIN {VENT_SUBSPACES_TABLE_NAME} ON {GENERAL_SPACE_TYPE_TABLE_NAME}.ventilation_space_type_name = {VENT_SUBSPACES_TABLE_NAME}.ventilation_space_type_name + WHERE space_type = '%s' AND level_3_lighting_definition_table = '%s' AND level_3_ventilation_definition_table = '%s' +""" + + +def update_openstudio_standards_space_data( + conn: sqlite3.Connection, json_data: list[dict] +): + """ + update existing openstudio_standards space_data + :param conn: + :param json_data: + :return: + """ + for space_data in json_data: + template = getattr_(space_data, "space", "template") + space_type = getattr_(space_data, "space", "space_type") + + # mandatory + lighting_primary_space_type = getattr_( + space_data, "space", "lighting_primary_space_type" + ) + lighting_secondary_space_type = getattr_( + space_data, "space", "lighting_secondary_space_type" + ) + ventilation_primary_space_type = getattr_( + space_data, "space", "ventilation_primary_space_type" + ) + ventilation_secondary_space_type = getattr_( + space_data, "space", "ventilation_secondary_space_type" + ) + + # Step 1, we need to get the template table and loop in the table + standard_template = fetch_template_data_by_template_first(conn, template) + lighting_standard_table = standard_template["lighting_standard_table"] + ventilation_standard_table = standard_template["ventilation_standard_table"] + + fetch_query = FETCH_SPACE_TO_TABLE_QUEYR % ( + space_type, + lighting_standard_table, + ventilation_standard_table, + ) + cur = conn.cursor() + cur.execute(fetch_query) + + assert ( + cur.arraysize > 0 + ), f"Cannot find data match the criteria of space_type='{space_type}', lighting_standard_table='{lighting_standard_table}', ventilation_standard_table='{ventilation_standard_table}'" + + # loop through the rows in table + for row in cur: + level_3_lighting_defintion_id = row[ + SPACE_TABLE_HEADER.index("level_3_lighting_defintion_id") + ] + level_3_ventilation_defintion_id = row[ + SPACE_TABLE_HEADER.index("level_3_ventilation_defintion_id") + ] + + # update lighting + light_tables = tables.__get_light_tables__() + # Find the matching data table and initialize it. + light_table = next( + filter( + lambda t: t[1]().data_table_name == lighting_standard_table, + light_tables, + ) + )[1]() + light_table.validate_record_datatype(space_data) + + lighting_update_dict = match_dict_data_by_key( + space_data, light_table.record_template + ) + + search_condition = ( + "id=%s AND lighting_primary_space_type='%s' AND lighting_secondary_space_type='%s'" + % ( + level_3_lighting_defintion_id, + lighting_primary_space_type, + lighting_secondary_space_type, + ) + ) + update_a_table( + conn, lighting_standard_table, lighting_update_dict, search_condition + ) + + # update ventilation + ventilation_update_dict = { + "ventilation_per_person": space_data.get("ventilation_per_person"), + "ventilation_per_person_unit": space_data.get( + "ventilation_per_person_unit" + ), + "ventilation_per_area": space_data.get("ventilation_per_area"), + "ventilation_per_area_unit": space_data.get( + "ventilation_per_area_unit" + ), + "occupancy_per_area": space_data.get("occupancy_per_area"), + "occupancy_per_area_unit": space_data.get("occupancy_per_area_unit"), + "air_class": space_data.get("air_class"), + "os": space_data.get("os"), + } + search_condition = ( + "id=%s AND ventilation_primary_space_type='%s' AND ventilation_secondary_space_type='%s'" + % ( + level_3_ventilation_defintion_id, + ventilation_primary_space_type, + ventilation_secondary_space_type, + ) + ) + update_a_table( + conn, + ventilation_standard_table, + ventilation_update_dict, + search_condition, + ) + + # update plug load table + if space_data.get("electric_equipment_space_type_name"): + plug_load_table = EquipLoadTable() + plug_load_update = match_dict_data_by_key( + space_data, plug_load_table.record_template + ) + search_condition = "electric_equipment_space_type_name='%s'" % ( + space_data["electric_equipment_space_type_name"] + ) + update_a_table( + conn, + plug_load_table.data_table_name, + plug_load_update, + search_condition, + ) diff --git a/data/openstudio_standards_data/client.py b/data/openstudio_standards_data/client.py new file mode 100644 index 0000000000..7abc5c9f17 --- /dev/null +++ b/data/openstudio_standards_data/client.py @@ -0,0 +1,55 @@ +from applications.create_openstudio_standards_json import ( + create_openstudio_standards_building_data_json, +) +from applications.database_maintenance import ( + export_openstudio_standards_database_to_json, + export_openstudio_standards_database_to_csv, + create_openstudio_standards_database_from_csv, + create_openstudio_standards_database_from_json, +) + +# create_openstudio_standards_database() +# create_openstudio_standards_building_data_json("openstudio_standards_building_data.json", "openstudio_standards_database.db") +from applications.form.update_space_data import update_openstudio_standards_space_data +from database_engine.database import create_connect +from query.fetch.database_table import fetch_a_record_from_table_by_id + +conn = create_connect(None) +# create_openstudio_standards_database_from_csv(conn) +# a = fetch_a_record_from_table_by_id(conn, "level_3_lighting_90_1_2019", 1) +# export_openstudio_standards_database_to_csv(conn, "") +# export_openstudio_standards_database_to_json(conn, "initial_data/") +# create_openstudio_standards_database_from_json(conn) +# create_openstudio_standards_building_data_json(conn, 'openstudio_standards_building_data.json') +update_json = [ + { + "template": "2019", + "lighting_standard": "ASHRAE 90.1-2019", + "ventilation_standard": "ASHRAE 62.1-2019", + "space_type": "audience seating - convention center", + "method": "CS", + "lighting_primary_space_type": "Audience Seating Area", + "lighting_per_area": 0.23, + "lighting_secondary_space_type": "All other audience seating areas", + "lighting_per_area_unit": "W/ft2", + "annotation": "", + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Auditorium seating area", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 150, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "electric_equipment_space_type_name": "audience seating - convention center", + "electric_equipment_minimum_epd": 0.63, + "electric_equipment_average_epd": 0.90, + "electric_equipment_median_epd": 0.63, + "electric_equipment_maximum_epd": 0.63, + "electric_equipment_epd_unit": "W/ft2", + } +] + +update_openstudio_standards_space_data(conn, update_json) diff --git a/data/openstudio_standards_data/database_engine/__init__.py b/data/openstudio_standards_data/database_engine/__init__.py new file mode 100644 index 0000000000..e69de29bb2 diff --git a/data/openstudio_standards_data/database_engine/assertions.py b/data/openstudio_standards_data/database_engine/assertions.py new file mode 100644 index 0000000000..bf1cf0bc6f --- /dev/null +++ b/data/openstudio_standards_data/database_engine/assertions.py @@ -0,0 +1,60 @@ +class OpenStudioStandardsDataException(Exception): + def __init__(self, message): + super().__init__(message) + + +class OpenStudioStandardsFormDataException(OpenStudioStandardsDataException): + def __init__(self, message): + super().__init__(message) + + +def assert_(b: bool, err_msg: str): + if not b: + raise OpenStudioStandardsFormDataException(err_msg) + + +class MissingKeyException(OpenStudioStandardsDataException): + def __init__(self, object_name, first_key): + message = f"{object_name} is missing {'one of the fields in: ' if isinstance(first_key, list) else ''}{first_key}" + super().__init__(message) + + +def getattr_(obj, obj_name: str, first_key, *remaining_keys): + """Gets the value inside a dictionary described by a key path or raises an expection + + Parameters + ---------- + obj : dict + A potentially nested dictionary of dictionaries to be searched. At each + level along the key path, the dictionary must have an id field. + obj_name : str + The name for the dictionary to be searched + first_key : str + The first key in the path + remaining_keys: [str] + Any additional keys in the path + + Returns + ------- + any + The value stored the the given key path + + Raises + ------ + AssertionError if the key path does not exist. The error message indicates what + field was missing. + """ + assert_( + obj is not None, + f"Object: {obj_name} provided is None, failed to search for key: {first_key}", + ) + + if first_key not in obj: + raise MissingKeyException(obj_name, first_key) + val = obj[first_key] + + return ( + val + if len(remaining_keys) == 0 + else getattr_(val, first_key, remaining_keys[0], *remaining_keys[1:]) + ) diff --git a/data/openstudio_standards_data/database_engine/database.py b/data/openstudio_standards_data/database_engine/database.py new file mode 100644 index 0000000000..2999599f82 --- /dev/null +++ b/data/openstudio_standards_data/database_engine/database.py @@ -0,0 +1,159 @@ +import sqlite3 +from sqlite3 import Error +import csv +import json + +DB_FILE = "openstudio_standards_database.db" + + +def create_connect(db_file): + """ + create a database_tables conection to the SQLite database_tables specified by db_file + :param db_file: database_tables file or None (None uses default + :return: Connection object or None + """ + conn = None + try: + conn = sqlite3.connect(db_file if db_file else DB_FILE) + # enable foreign keys execution + conn.execute("PRAGMA foreign_keys = 1") + except Error as e: + print(e) + return conn + + +class DBOperation: + def __init__(self, table_name, record_template, initial_data_directory): + """ + DB Operation class + :param table_name: String name of the table + :param record_template: dictionary record template + :param initial_data_directory: String initial data directory + """ + self.data_table_name = table_name + self.record_template = record_template + self.initial_data_directory = initial_data_directory + + def create_a_table(self, connection): + """ + Create a table - no return + :param connection: + :return: + """ + print(f"creating table: {self.data_table_name}") + connection.execute(self._get_create_table_query()) + return True + + def add_a_record(self, connection, record: dict): + """ + Add a record to a table + :param connection: + :param record: dict contains the dictionary of record + :return: the index of the newly inserted record. + """ + # run data validation, raise exception if data is not validated. + cur = connection.cursor() + + self.validate_record_datatype(record) + cur.execute(self._get_insert_record_query(), self._preprocess_record(record)) + connection.commit() + return cur.lastrowid + + def get_all_records(self, connection): + """ + Retrieve all data records + :param connection: + :return: + """ + return connection.execute(self._get_retrieve_all_query()).fetchall() + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + pass + + def get_record_template(self): + """ + Get a record template of a table + :return: + """ + return self.record_template + + def validate_record_datatype(self, record): + """ + Validate the data. This function shall be used to set special data requirement that SQLite schema cannot + verify. e.g., a data's data type shall be int. + + :param record: dict + A dictionary that contains a map column to value in a row. + :return: boolean + """ + return True + + def export_table_to_csv(self, conn, save_dir=""): + """ + A function that exports the table into a .csv file + + :param conn: SQLite3Connection object + :param save_dir: str, path that saves the csv file + :return: + """ + cursor = conn.cursor() + cursor.execute(self._get_retrieve_all_query()) + csv_dir = f"{save_dir}{self.data_table_name}.csv" + with open(csv_dir, "w", newline="") as csv_file: + csv_writer = csv.writer(csv_file, delimiter=",") + csv_writer.writerow([i[0] for i in cursor.description]) + csv_writer.writerows(cursor) + + def export_table_to_json(self, conn, save_dir=""): + """ + A function that exports the table into a .json file + + :param conn: SQLite3Connection object + :param save_dir: str, path that saves the json file + :return: + """ + cursor = conn.cursor() + cursor.execute(self._get_retrieve_all_query()) + r = [ + dict((cursor.description[i][0], value) for i, value in enumerate(row)) + for row in cursor.fetchall() + ] + + json_dir = f"{save_dir}{self.data_table_name}.json" + json_output = json.dumps(r, indent=4) + with open(json_dir, "w", newline="") as json_file: + json_file.write(json_output) + + def _preprocess_record(self, record): + """ + Function that pre-process a record before insert to Table. + + :param record: + :return: + """ + pass + + def _get_create_table_query(self): + """ + Function to create a table + :return: + """ + pass + + def _get_insert_record_query(self): + """ + Function to insert a query + :return: + """ + pass + + def _get_retrieve_all_query(self): + """ + Function to retrieve all records in a table + :return: + """ + return f"SELECT * FROM {self.data_table_name}" diff --git a/data/openstudio_standards_data/database_engine/database_util.py b/data/openstudio_standards_data/database_engine/database_util.py new file mode 100644 index 0000000000..a04fff3e4a --- /dev/null +++ b/data/openstudio_standards_data/database_engine/database_util.py @@ -0,0 +1,73 @@ +import csv +import json + + +def read_csv_to_tuples(csv_dir): + """ + Read csv, convert each row to a tuple + :param csv_dir: + :return: list list of tuple + """ + table_list = [] + with open(csv_dir) as csv_file: + csv_reader = csv.reader(csv_file, delimiter=",") + for row in csv_reader: + # remove empty strings in the record + new_row = [cell if cell else None for cell in row] + table_list.append(tuple(new_row)) + + return table_list + + +def read_csv_to_list_dict(csv_dir): + """ + Read csv, convert to list of dictionaries + :param csv_dir: + :return: list list of dictionary + """ + with open(csv_dir, mode="r") as csv_file: + csv_reader = csv.DictReader(csv_file, delimiter=",") + table_list = [ + {key: row[key] for key in row if key != "id"} for row in csv_reader + ] + return table_list + + +def read_json_to_list_dict(json_dir): + """ + Read json, convert to list of dictionaries + :param json_dir: + :return: list list of dictionary + """ + with open(json_dir, mode="r") as json_file: + json_table = json.loads(json_file.read()) + table_list = [ + {key: record[key] for key in record if key != "id"} for record in json_table + ] + return table_list + + +def is_float(element: any) -> bool: + """ + Test to verify if an element is float data type + :param element: + :return: + """ + if element is None: + return False + try: + float(element) + except ValueError: + return False + return True + + +def getattr_either(key: str, record: dict, option=None): + """ + A helper function to retrieve a key from a record object (dict) with an option for reject solution. + :param key: key + :param record: dictionary that could contain value for the key. + :param option: value return when reject (optional), default is None + :return: value + """ + return record[key] if record.get(key) else option diff --git a/data/openstudio_standards_data/database_tables/__init__.py b/data/openstudio_standards_data/database_tables/__init__.py new file mode 100644 index 0000000000..73251ab19f --- /dev/null +++ b/data/openstudio_standards_data/database_tables/__init__.py @@ -0,0 +1,83 @@ +import importlib +import inspect + +import database_engine.database as database_classes +import database_tables as db_tables + +# need to be in orders of complexity +# Tables with no foreign key need to be created +# before other tables +__all__ = [ + # tables no foreign keys + "hvac_minimum_requirement_motors_90_1", + "hvac_minimum_requirement_water_heaters_90_1", + "hvac_minimum_requirement_heat_rejection_90_1", + "hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1", + "hvac_minimum_requirement_water_source_heat_pumps_heating_90_1", + "hvac_minimum_requirement_unitary_air_conditioners_90_1", + "hvac_minimum_requirement_heat_pump_cooling_90_1", + "hvac_minimum_requirement_heat_pump_heating_90_1", + "hvac_minimum_requirement_chillers_90_1", + "hvac_minimum_requirement_boilers_90_1", + "hvac_minimum_requirement_furnaces_90_1", + "level_3_lighting_90_1_2019", + "level_3_lighting_90_1_2004", + "level_3_ventilation_62_1_2004", + "level_3_ventilation_62_1_2019", + "level_2_electric_equipment", + "support_standard_templates", + "support_lighting_space_type_name_tags", + "support_ventilation_space_type_name_tags", + "support_electric_equipment_space_type_name_tags", + "support_materials", + "support_performance_curves", + "system_requirement_energy_recovery_90_1", + "system_requirement_economizer_90_1", + # tables with foreign keys + "level_2_lighting_space_types", + "level_2_ventilation_space_types", + "level_1_space_types", + "envelope_requirement", + "support_constructions", +] + + +def __get_light_tables__(): + available_tables = __gettables__() + return [table for table in available_tables if table[0].startswith("LightDef")] + + +def __gettables__(): + tables = inspect.getmembers(db_tables, inspect.ismodule) + # sort the list tuples to the same order as __all__ + tables_sorted = [ + table for table_name in __all__ for table in tables if table_name == table[0] + ] + base_class_names = [ + f[0] for f in inspect.getmembers(database_classes, inspect.isclass) + ] + available_tables = [] + for table in tables_sorted: + available_tables += [ + f + for f in inspect.getmembers( + table[1], + lambda obj: inspect.isclass(obj) + and issubclass(obj, database_classes.DBOperation), + ) + if (not f[0].startswith("_")) + and (not f[0] in base_class_names) + and (f[0].endswith("Table")) + ] + + return available_tables + + +def __getattr__(name): + if name in __all__: + return importlib.import_module("." + name, __name__) + raise AttributeError(f"module {__name__!r} has no attribute {name!r}") + + +def __dir__(): + return __all__ diff --git a/data/openstudio_standards_data/database_tables/envelope_requirement.py b/data/openstudio_standards_data/database_tables/envelope_requirement.py new file mode 100644 index 0000000000..dc0396e54e --- /dev/null +++ b/data/openstudio_standards_data/database_tables/envelope_requirement.py @@ -0,0 +1,176 @@ +from database_engine.database import DBOperation +from database_engine.database_util import is_float, getattr_either + +TABLE_NAME = "envelope_requirement" + +RECORD_HELP = """ +Must provide a tuple that contains: +template: TEXT +climate_zone_set: TEXT +intended_surface_type: TEXT +standard_construction_type: TEXT +building_category: TEXT +construction: TEXT +orientation: TEXT +minimum_percent_of_surface: NUMERIC +maximum_percent_of_surface: NUMERIC +assembly_maximum_u_value: NUMERIC +u_value_includes_interior_film_coefficient: TEXT +u_value_includes_exterior_film_coefficient: TEXT +assembly_maximum_f_factor: NUMERIC +assembly_maximum_c_factor: NUMERIC +assembly_maximum_solar_heat_gain_coefficient: NUMERIC +assembly_minimum_vt_SHGC: NUMERIC +annotation: TEXT (optional) +""" + +CREATE_ENVELOPE_REQUIREMENTS_TABLE = """ +CREATE TABLE IF NOT EXISTS %s +(id INTEGER PRIMARY KEY, +template TEXT NOT NULL, +climate_zone_set TEXT NOT NULL, +intended_surface_type TEXT NOT NULL, +standard_construction_type TEXT, +building_category TEXT NOT NULL, +construction TEXT NOT NULL, +orientation TEXT, +minimum_percent_of_surface NUMERIC, +maximum_percent_of_surface NUMERIC, +assembly_maximum_u_value NUMERIC, +u_value_includes_interior_film_coefficient TEXT, +u_value_includes_exterior_film_coefficient TEXT, +assembly_maximum_f_factor NUMERIC, +assembly_maximum_c_factor NUMERIC, +assembly_maximum_solar_heat_gain_coefficient NUMERIC, +assembly_minimum_vt_shgc NUMERIC, +annotation TEXT, +FOREIGN KEY(construction) REFERENCES support_constructions(name) +); +""" + +INSERT_A_ENVELOPE_REQUIREMENT_RECORD = """ + INSERT INTO %s ( +template, +climate_zone_set, +intended_surface_type, +standard_construction_type, +building_category, +construction, +orientation, +minimum_percent_of_surface, +maximum_percent_of_surface, +assembly_maximum_u_value, +u_value_includes_interior_film_coefficient, +u_value_includes_exterior_film_coefficient, +assembly_maximum_f_factor, +assembly_maximum_c_factor, +assembly_maximum_solar_heat_gain_coefficient, +assembly_minimum_vt_shgc, +annotation +) +VALUES (?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?); +""" + +RECORD_TEMPLATE = { + "template": "", + "climate_zone_set": "", + "intended_surface_type": "", + "standard_construction_type": "", + "building_category": "", + "construction": "", + "orientation": "", + "minimum_percent_of_surface": 0.0, + "maximum_percent_of_surface": 0.0, + "assembly_maximum_u_value": 0.0, + "u_value_includes_interior_film_coefficient": 0.0, + "u_value_includes_exterior_film_coefficient": 0.0, + "assembly_maximum_f_factor": 0.0, + "assembly_maximum_c_factor": 0.0, + "assembly_maximum_solar_heat_gain_coefficient": 0.0, + "assembly_minimum_vt_shgc": 0.0, + "annotation": "", +} + + +class EnvelopeRequirementTable(DBOperation): + def __init__(self): + super(EnvelopeRequirementTable, self).__init__( + table_name=TABLE_NAME, + record_template=RECORD_TEMPLATE, + initial_data_directory=f"initial_data/{TABLE_NAME}", + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def validate_record_datatype(self, record): + str_expected = [ + "template", + "climate_zone_set", + "intended_surface_type", + "standard_construction_type", + "building_category", + "construction", + "orientation", + "value_includes_interior_film_coefficient", + "value_includes_exterior_film_coefficient", + ] + + for f in str_expected: + if record.get(f): + assert isinstance( + record[f], str + ), f"{f} requires to be a string, instead got {record[f]}" + + float_expected = [ + "minimum_percent_of_surface", + "maximum_percent_of_surface", + "assembly_maximum_u_value", + "assembly_maximum_f_factor", + "assembly_maximum_c_factor", + "assembly_maximum_solar_heat_gain_coefficient", + "assembly_minimum_vt_shgc", + ] + + for f in float_expected: + if record.get(f): + assert is_float( + record.get(f) + ), f"{f} requires to be numeric data type, instead got {record[f]}" + + def _preprocess_record(self, record): + """ + + :param record: dict + :return: + """ + + return ( + getattr_either("template", record), + getattr_either("climate_zone_set", record), + getattr_either("intended_surface_type", record), + getattr_either("standard_construction_type", record), + getattr_either("building_category", record), + getattr_either("construction", record), + getattr_either("orientation", record), + getattr_either("minimum_percent_of_surface", record), + getattr_either("maximum_percent_of_surface", record), + getattr_either("assembly_maximum_u_value", record), + getattr_either("u_value_includes_interior_film_coefficient", record), + getattr_either("u_value_includes_exterior_film_coefficient", record), + getattr_either("assembly_maximum_f_factor", record), + getattr_either("assembly_maximum_c_factor", record), + getattr_either("assembly_maximum_solar_heat_gain_coefficient", record), + getattr_either("assembly_minimum_vt_shgc", record), + getattr_either("annotation", record), + ) + + def _get_create_table_query(self): + return CREATE_ENVELOPE_REQUIREMENTS_TABLE % self.data_table_name + + def _get_insert_record_query(self): + return INSERT_A_ENVELOPE_REQUIREMENT_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_boilers.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_boilers.py new file mode 100644 index 0000000000..5f65a8408a --- /dev/null +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_boilers.py @@ -0,0 +1,152 @@ +from database_engine.database import DBOperation +from database_engine.database_util import is_float, getattr_either + +RECORD_HELP = """ +Must provide a tuple that contains: +template: TEXT +fluid_type: TEXT +fuel_type: TEXT +condensing: NUMERIC +condensing_control: NUMERIC +minimum_capacity: NUMERIC +maximum_capacity: NUMERIC +start_date: TEXT +end_date: TEXT +minimum_annual_fuel_utilization_efficiency: NUMERIC +minimum_thermal_efficiency: NUMERIC +minimum_combustion_efficiency: NUMERIC +efffplr: NUMERIC +annotation: TEXT (optional) +""" + +CREATE_HVAC_REQ_BOILER_TABLE = """ +CREATE TABLE IF NOT EXISTS %s +(id INTEGER PRIMARY KEY, +template TEXT NOT NULL, +fluid_type TEXT NOT NULL, +fuel_type TEXT NOT NULL, +condensing TEXT, +condensing_control TEXT, +minimum_capacity NUMERIC, +maximum_capacity NUMERIC, +start_date TEXT NOT NULL, +end_date TEXT NOT NULL, +minimum_annual_fuel_utilization_efficiency NUMERIC, +minimum_thermal_efficiency NUMERIC, +minimum_combustion_efficiency NUMERIC, +efffplr NUMERIC, +annotation TEXT); +""" + +INSERT_A_BOILER_RECORD = """ + INSERT INTO %s ( +template, +fluid_type, +fuel_type, +condensing, +condensing_control, +minimum_capacity, +maximum_capacity, +start_date, +end_date, +minimum_annual_fuel_utilization_efficiency, +minimum_thermal_efficiency, +minimum_combustion_efficiency, +efffplr, +annotation +) +VALUES (?, ?, ?, ? ,? , ?, ?, ?, ?, ?, ?, ?, ?, ?); +""" + +RECORD_TEMPLATE = { + "template": "", + "fluid_type": "", + "fuel_type": "", + "condensing": 0.0, + "condensing_control": 0.0, + "minimum_capacity": 0.0, + "maximum_capacity": 0.0, + "start_date": "", + "end_date": "", + "minimum_annual_fuel_utilization_efficiency": 0.0, + "minimum_thermal_efficiency": 0.0, + "minimum_combustion_efficiency": 0.0, + "efffplr": "", + "annotation": "", +} + + +class HVACMinReqBoilers(DBOperation): + def __init__(self, table_name, initial_data_directory): + super(HVACMinReqBoilers, self).__init__( + table_name=table_name, + record_template=RECORD_TEMPLATE, + initial_data_directory=initial_data_directory, + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def validate_record_datatype(self, record): + str_expected = [ + "template", + "fluid_type", + "condensing", + "condensing_control", + "start_date", + "end_date", + "efffplr", + ] + + for f in str_expected: + if record.get(f): + assert isinstance( + record[f], str + ), f"{f} requires to be a string, instead got {record[f]}" + + float_expected = [ + "minimum_capacity", + "maximum_capacity", + "minimum_annual_fuel_utilization_efficiency", + "minimum_thermal_efficiency", + "minimum_combustion_efficiency", + ] + + for f in float_expected: + if record.get(f): + assert is_float( + record.get(f) + ), f"{f} requires to be numeric data type, instead got {record[f]}" + + def _preprocess_record(self, record): + """ + + :param record: dict + :return: + """ + return ( + getattr_either("template", record), + getattr_either("fluid_type", record), + getattr_either("fuel_type", record), + getattr_either("condensing", record), + getattr_either("condensing_control", record), + getattr_either("minimum_capacity", record), + getattr_either("maximum_capacity", record), + getattr_either("start_date", record), + getattr_either("end_date", record), + getattr_either("minimum_annual_fuel_utilization_efficiency", record), + getattr_either("minimum_thermal_efficiency", record), + getattr_either("minimum_combustion_efficiency", record), + getattr_either("efffplr", record), + getattr_either("annotation", record, ""), + ) + + def _get_create_table_query(self): + return CREATE_HVAC_REQ_BOILER_TABLE % self.data_table_name + + def _get_insert_record_query(self): + return INSERT_A_BOILER_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_boilers_90_1.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_boilers_90_1.py new file mode 100644 index 0000000000..28822f9b1a --- /dev/null +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_boilers_90_1.py @@ -0,0 +1,13 @@ +import sqlite3 + +from database_tables.hvac_minimum_requirement_boilers import HVACMinReqBoilers + +TABLE_NAME = "hvac_minimum_requirement_boilers_90_1" + + +class HVACMinReqBoilers901Table(HVACMinReqBoilers): + def __init__(self): + super(HVACMinReqBoilers901Table, self).__init__( + table_name=TABLE_NAME, + initial_data_directory=f"initial_data/{TABLE_NAME}", + ) diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_chillers.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_chillers.py new file mode 100644 index 0000000000..a1d4f1c58f --- /dev/null +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_chillers.py @@ -0,0 +1,166 @@ +from database_engine.database import DBOperation +from database_engine.database_util import is_float, getattr_either + +RECORD_HELP = """ +Must provide a tuple that contains: +template: TEXT +cooling_type: TEXT +condenser_type: TEXT +compressor_type: TEXT +absorption_type: TEXT +variable_speed_drive: TEXT +minimum_capacity: NUMERIC +maximum_capacity: NUMERIC +start_date: TEXT +end_date: TEXT +minimum_full_load_efficiency: NUMERIC +minimum_integrated_part_load_value: NUMERIC +capft: TEXT +eirft: TEXT +eirfplr: TEXT +annotation: TEXT (optional) +""" + +CREATE_HVAC_REQUIREMENT_CHILLERS_TABLE = """ +CREATE TABLE IF NOT EXISTS %s +(id INTEGER PRIMARY KEY, +template TEXT NOT NULL, +cooling_type TEXT, +condenser_type TEXT, +compressor_type TEXT, +absorption_type TEXT, +variable_speed_drive TEXT, +minimum_capacity NUMERIC, +maximum_capacity NUMERIC, +start_date TEXT, +end_date TEXT, +minimum_full_load_efficiency NUMERIC, +minimum_integrated_part_load_value NUMERIC, +capft TEXT, +eirft TEXT, +eirfplr TEXT, +annotation TEXT); +""" + +INSERT_A_CHILLER_RECORD = """ + INSERT INTO %s ( +template, +cooling_type, +condenser_type, +compressor_type, +absorption_type, +variable_speed_drive, +minimum_capacity, +maximum_capacity, +start_date, +end_date, +minimum_full_load_efficiency, +minimum_integrated_part_load_value, +capft, +eirft, +eirfplr, +annotation +) +VALUES (?, ?, ?, ? ,? , ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?); +""" + +RECORD_TEMPLATE = { + "template": "", + "cooling_type": "", + "condenser_type": "", + "compressor_type": "", + "absorption_type": "", + "variable_speed_drive": "", + "minimum_capacity": 0.0, + "maximum_capacity": 0.0, + "start_date": "", + "end_date": "", + "minimum_full_load_efficiency": 0.0, + "minimum_integrated_part_load_value": 0.0, + "capft": "", + "eirft": "", + "eirfplr": "", + "annotation": "", +} + + +class HVACMinimumRequirementChillers(DBOperation): + def __init__(self, table_name, initial_data_directory): + super(HVACMinimumRequirementChillers, self).__init__( + table_name=table_name, + record_template=RECORD_TEMPLATE, + initial_data_directory=initial_data_directory, + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def validate_record_datatype(self, record): + str_expected = [ + "template", + "cooling_type", + "condenser_type", + "compressor_type", + "absorption_type", + "variable_speed_drive", + "start_date", + "end_date", + "capft", + "eirft", + "eirfplr", + ] + + for f in str_expected: + if record.get(f): + assert isinstance( + record[f], str + ), f"{f} requires to be a string, instead got {record[f]}" + + float_expected = [ + "minimum_capacity", + "maximum_capacity", + "minimum_full_load_efficiency", + "minimum_integrated_part_load_value", + ] + + for f in float_expected: + if record.get(f): + assert is_float( + record.get(f) + ), f"{f} requires to be numeric data type, instead got {record[f]}" + + def _preprocess_record(self, record): + """ + + :param record: dict + :return: + """ + + return ( + getattr_either("template", record), + getattr_either("cooling_type", record), + getattr_either("condenser_type", record), + getattr_either("compressor_type", record), + getattr_either("absorption_type", record), + getattr_either("variable_speed_drive", record), + getattr_either("minimum_capacity", record), + getattr_either("maximum_capacity", record), + getattr_either("start_date", record), + getattr_either("end_date", record), + getattr_either("minimum_full_load_efficiency", record), + getattr_either("minimum_integrated_part_load_value", record), + getattr_either("capft", record), + getattr_either("eirft", record), + getattr_either("eirfplr", record), + getattr_either("annotation", record), + ) + + def _get_create_table_query(self): + return CREATE_HVAC_REQUIREMENT_CHILLERS_TABLE % self.data_table_name + + def _get_insert_record_query(self): + return INSERT_A_CHILLER_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_chillers_90_1.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_chillers_90_1.py new file mode 100644 index 0000000000..5486386771 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_chillers_90_1.py @@ -0,0 +1,15 @@ +import sqlite3 + +from database_tables.hvac_minimum_requirement_chillers import ( + HVACMinimumRequirementChillers, +) + +TABLE_NAME = "hvac_minimum_requirement_chillers_90_1" + + +class HVACMinimumRequirementChillers901Table(HVACMinimumRequirementChillers): + def __init__(self): + super(HVACMinimumRequirementChillers901Table, self).__init__( + table_name=TABLE_NAME, + initial_data_directory=f"initial_data/{TABLE_NAME}", + ) diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_furnaces.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_furnaces.py new file mode 100644 index 0000000000..56cc2374c2 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_furnaces.py @@ -0,0 +1,124 @@ +from database_engine.database import DBOperation +from database_engine.database_util import is_float, getattr_either + +RECORD_HELP = """ +Must provide a tuple that contains: +template: TEXT +minimum_capacity: NUMERIC +maximum_capacity: NUMERIC +start_date: TEXT +end_date: TEXT +minimum_annual_fuel_utilization_efficiency: NUMERIC +minimum_thermal_efficiency: NUMERIC +minimum_combustion_efficiency: NUMERIC +annotation: TEXT (optional) +""" + +CREATE_HVAC_REQUIREMENT_FURNACES_TABLE = """ +CREATE TABLE IF NOT EXISTS %s +(id INTEGER PRIMARY KEY, +template TEXT NOT NULL, +minimum_capacity NUMERIC, +maximum_capacity NUMERIC, +start_date TEXT NOT NULL, +end_date TEXT NOT NULL, +minimum_annual_fuel_utilization_efficiency NUMERIC, +minimum_thermal_efficiency NUMERIC, +minimum_combustion_efficiency NUMERIC, +annotation TEXT); +""" + +INSERT_A_FURNACE_RECORD = """ + INSERT INTO %s ( +template, +minimum_capacity, +maximum_capacity, +start_date, +end_date, +minimum_annual_fuel_utilization_efficiency, +minimum_thermal_efficiency, +minimum_combustion_efficiency, +annotation +) +VALUES (?, ?, ?, ? ,? , ?, ?, ?, ?); +""" + +RECORD_TEMPLATE = { + "template": "", + "minimum_capacity": 0.0, + "maximum_capacity": 0.0, + "start_date": "", + "end_date": "", + "minimum_annual_fuel_utilization_efficiency": 0.0, + "minimum_thermal_efficiency": 0.0, + "minimum_combustion_efficiency": 0.0, + "annotation": "", +} + + +class HVACMinimumRequirementFurnaces(DBOperation): + def __init__(self, table_name, initial_data_directory): + super(HVACMinimumRequirementFurnaces, self).__init__( + table_name=table_name, + record_template=RECORD_TEMPLATE, + initial_data_directory=initial_data_directory, + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def validate_record_datatype(self, record): + str_expected = [ + "template", + "start_date", + "end_date", + ] + + for f in str_expected: + if record.get(f): + assert isinstance( + record[f], str + ), f"{f} requires to be a string, instead got {record[f]}" + + float_expected = [ + "minimum_capacity", + "maximum_capacity", + "minimum_annual_fuel_utilization_efficiency", + "minimum_thermal_efficiency", + "minimum_combustion_efficiency", + ] + + for f in float_expected: + if record.get(f): + assert is_float( + record.get(f) + ), f"{f} requires to be numeric data type, instead got {record[f]}" + + def _preprocess_record(self, record): + """ + + :param record: dict + :return: + """ + + return ( + getattr_either("template", record), + getattr_either("minimum_capacity", record), + getattr_either("maximum_capacity", record), + getattr_either("start_date", record), + getattr_either("end_date", record), + getattr_either("minimum_annual_fuel_utilization_efficiency", record), + getattr_either("minimum_thermal_efficiency", record), + getattr_either("minimum_combustion_efficiency", record), + getattr_either("annotation", record), + ) + + def _get_create_table_query(self): + return CREATE_HVAC_REQUIREMENT_FURNACES_TABLE % self.data_table_name + + def _get_insert_record_query(self): + return INSERT_A_FURNACE_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_furnaces_90_1.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_furnaces_90_1.py new file mode 100644 index 0000000000..015857c025 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_furnaces_90_1.py @@ -0,0 +1,15 @@ +import sqlite3 + +from database_tables.hvac_minimum_requirement_furnaces import ( + HVACMinimumRequirementFurnaces, +) + +TABLE_NAME = "hvac_minimum_requirement_furnaces_90_1" + + +class HVACMinimumRequirementFurnaces901Table(HVACMinimumRequirementFurnaces): + def __init__(self): + super(HVACMinimumRequirementFurnaces901Table, self).__init__( + table_name=TABLE_NAME, + initial_data_directory=f"initial_data/{TABLE_NAME}", + ) diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_cooling.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_cooling.py new file mode 100644 index 0000000000..ff2d4b5298 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_cooling.py @@ -0,0 +1,190 @@ +from database_engine.database import DBOperation +from database_engine.database_util import is_float, getattr_either + +RECORD_HELP = """ +Must provide a tuple that contains: +template: TEXT +cooling_type: TEXT +heating_type: TEXT +subcategory: TEXT +minimum_capacity: NUMERIC +maximum_capacity: NUMERIC +start_date: TEXT +end_date: TEXT +minimum_seasonal_efficiency: NUMERIC +minimum_full_load_efficiency: NUMERIC +minimum_iplv: NUMERIC +minimum_integrated_energy_efficiency_ratio: NUMERIC +pthp_eer_coefficient_1: NUMERIC +pthp_eer_coefficient_2: NUMERIC +cool_cap_ft: TEXT +cool_cap_fflow: TEXT +cool_eir_ft: TEXT +cool_eir_fflow: TEXT +cool_plf_fplr: TEXT +annotation: TEXT (optional) +""" + +CREATE_HVAC_REQUIREMENT_HEAT_PUMP_COOLING_TABLE = """ +CREATE TABLE IF NOT EXISTS %s +(id INTEGER PRIMARY KEY, +template TEXT NOT NULL, +cooling_type TEXT NOT NULL, +heating_type TEXT NOT NULL, +subcategory TEXT NOT NULL, +minimum_capacity NUMERIC, +maximum_capacity NUMERIC, +start_date TEXT, +end_date TEXT, +minimum_seasonal_efficiency NUMERIC, +minimum_full_load_efficiency NUMERIC, +minimum_iplv NUMERIC, +minimum_integrated_energy_efficiency_ratio NUMERIC, +pthp_eer_coefficient_1 NUMERIC, +pthp_eer_coefficient_2 NUMERIC, +cool_cap_ft TEXT, +cool_cap_fflow TEXT, +cool_eir_ft TEXT, +cool_eir_fflow TEXT, +cool_plf_fplr TEXT, +annotation TEXT); +""" + +INSERT_A_HEAT_PUMP_COOLING_RECORD = """ + INSERT INTO %s ( +template, +cooling_type, +heating_type, +subcategory, +minimum_capacity, +maximum_capacity, +start_date, +end_date, +minimum_seasonal_efficiency, +minimum_full_load_efficiency, +minimum_iplv, +minimum_integrated_energy_efficiency_ratio, +pthp_eer_coefficient_1, +pthp_eer_coefficient_2, +cool_cap_ft, +cool_cap_fflow, +cool_eir_ft, +cool_eir_fflow, +cool_plf_fplr, +annotation +) +VALUES (?, ?, ?, ? ,? , ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?); +""" + +RECORD_TEMPLATE = { + "template": "", + "cooling_type": "", + "heating_type": "", + "subcategory": "", + "minimum_capacity": 0.0, + "maximum_capacity": 0.0, + "start_date": "", + "end_date": "", + "minimum_seasonal_efficiency": 0.0, + "minimum_full_load_efficiency": 0.0, + "minimum_iplv": 0.0, + "minimum_integrated_energy_efficiency_ratio": 0.0, + "pthp_eer_coefficient_1": 0.0, + "pthp_eer_coefficient_2": 0.0, + "cool_cap_ft": "", + "cool_cap_fflow": "", + "cool_eir_ft": "", + "cool_eir_fflow": "", + "cool_plf_fplr": "", + "annotation": "", +} + + +class HVACMinimumRequirementHeatPumpCooling(DBOperation): + def __init__(self, table_name, initial_data_directory): + super(HVACMinimumRequirementHeatPumpCooling, self).__init__( + table_name=table_name, + record_template=RECORD_TEMPLATE, + initial_data_directory=initial_data_directory, + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def validate_record_datatype(self, record): + str_expected = [ + "template", + "cooling_type", + "heating_type", + "subcategory", + "start_date", + "end_date", + "cool_cap_ft", + "cool_cap_fflow", + "cool_eir_ft", + "cool_eir_fflow", + "cool_plf_fplr", + ] + + for f in str_expected: + if record.get(f): + assert isinstance( + record[f], str + ), f"{f} requires to be a string, instead got {record[f]}" + + float_expected = [ + "minimum_capacity", + "maximum_capacity", + "minimum_seasonal_efficiency", + "minimum_full_load_efficiency", + "minimum_iplv", + "minimum_integrated_energy_efficiency_ratio", + "pthp_eer_coefficient_1", + "pthp_eer_coefficient_2", + ] + + for f in float_expected: + if record.get(f): + assert is_float( + record.get(f) + ), f"{f} requires to be numeric data type, instead got {record[f]}" + + def _preprocess_record(self, record): + """ + + :param record: dict + :return: + """ + + return ( + getattr_either("template", record), + getattr_either("cooling_type", record), + getattr_either("heating_type", record), + getattr_either("subcategory", record), + getattr_either("minimum_capacity", record), + getattr_either("maximum_capacity", record), + getattr_either("start_date", record), + getattr_either("end_date", record), + getattr_either("minimum_seasonal_efficiency", record), + getattr_either("minimum_full_load_efficiency", record), + getattr_either("minimum_iplv", record), + getattr_either("minimum_integrated_energy_efficiency_ratio", record), + getattr_either("pthp_eer_coefficient_1", record), + getattr_either("pthp_eer_coefficient_2", record), + getattr_either("cool_cap_ft", record), + getattr_either("cool_cap_fflow", record), + getattr_either("cool_eir_ft", record), + getattr_either("cool_eir_fflow", record), + getattr_either("cool_plf_fplr", record), + getattr_either("annotation", record), + ) + + def _get_create_table_query(self): + return CREATE_HVAC_REQUIREMENT_HEAT_PUMP_COOLING_TABLE % self.data_table_name + + def _get_insert_record_query(self): + return INSERT_A_HEAT_PUMP_COOLING_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_cooling_90_1.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_cooling_90_1.py new file mode 100644 index 0000000000..8709761d02 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_cooling_90_1.py @@ -0,0 +1,17 @@ +import sqlite3 + +from database_tables.hvac_minimum_requirement_heat_pump_cooling import ( + HVACMinimumRequirementHeatPumpCooling, +) + +TABLE_NAME = "hvac_minimum_requirement_heat_pump_cooling_90_1" + + +class HVACMinimumRequirementHeatPumpCooling901Table( + HVACMinimumRequirementHeatPumpCooling +): + def __init__(self): + super(HVACMinimumRequirementHeatPumpCooling901Table, self).__init__( + table_name=TABLE_NAME, + initial_data_directory=f"initial_data/{TABLE_NAME}", + ) diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_heating.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_heating.py new file mode 100644 index 0000000000..717657af49 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_heating.py @@ -0,0 +1,178 @@ +from database_engine.database import DBOperation +from database_engine.database_util import is_float, getattr_either + +RECORD_HELP = """ +Must provide a tuple that contains: +template: TEXT +cooling_type: TEXT +subcategory: TEXT +minimum_capacity: NUMERIC +maximum_capacity: NUMERIC +start_date: TEXT +end_date: TEXT +minimum_heating_seasonal_performance_factor: NUMERIC +minimum_coefficient_of_performance_heating: NUMERIC +minimum_energy_efficiency_ratio: NUMERIC +pthp_cop_coefficient_1: NUMERIC +pthp_cop_coefficient_2: NUMERIC +heat_cap_ft: TEXT +heat_cap_fflow: TEXT +heat_eir_ft: TEXT +heat_eir_fflow: TEXT +heat_plf_fplr: TEXT +annotation: TEXT (optional) +""" + +CREATE_HVAC_REQUIREMENT_HEAT_PUMP_HEATING_TABLE = """ +CREATE TABLE IF NOT EXISTS %s +(id INTEGER PRIMARY KEY, +template TEXT NOT NULL, +cooling_type TEXT NOT NULL, +subcategory TEXT NOT NULL, +minimum_capacity NUMERIC, +maximum_capacity NUMERIC, +start_date TEXT, +end_date TEXT, +minimum_heating_seasonal_performance_factor NUMERIC, +minimum_coefficient_of_performance_heating NUMERIC, +minimum_energy_efficiency_ratio NUMERIC, +pthp_cop_coefficient_1 NUMERIC, +pthp_cop_coefficient_2 NUMERIC, +heat_cap_ft TEXT, +heat_cap_fflow TEXT, +heat_eir_ft TEXT, +heat_eir_fflow TEXT, +heat_plf_fplr TEXT, +annotation TEXT); +""" + +INSERT_A_HEAT_PUMP_HEATING_RECORD = """ + INSERT INTO %s ( +template, +cooling_type, +subcategory, +minimum_capacity, +maximum_capacity, +start_date, +end_date, +minimum_heating_seasonal_performance_factor, +minimum_coefficient_of_performance_heating, +minimum_energy_efficiency_ratio, +pthp_cop_coefficient_1, +pthp_cop_coefficient_2, +heat_cap_ft, +heat_cap_fflow, +heat_eir_ft, +heat_eir_fflow, +heat_plf_fplr, +annotation +) +VALUES (?, ?, ?, ? ,? , ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?); +""" + +RECORD_TEMPLATE = { + "template": "", + "cooling_type": "", + "subcategory": "", + "minimum_capacity": 0.0, + "maximum_capacity": 0.0, + "start_date": "", + "end_date": "", + "minimum_heating_seasonal_performance_factor": 0.0, + "minimum_coefficient_of_performance_heating": 0.0, + "minimum_energy_efficiency_ratio": 0.0, + "pthp_cop_coefficient_1": 0.0, + "pthp_cop_coefficient_2": 0.0, + "heat_cap_ft": "", + "heat_cap_fflow": "", + "heat_eir_ft": "", + "heat_eir_fflow": "", + "heat_plf_fplr": "", + "annotation": "", +} + + +class HVACMinimumRequirementHeatPumpHeating(DBOperation): + def __init__(self, table_name, initial_data_directory): + super(HVACMinimumRequirementHeatPumpHeating, self).__init__( + table_name=table_name, + record_template=RECORD_TEMPLATE, + initial_data_directory=initial_data_directory, + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def validate_record_datatype(self, record): + str_expected = [ + "template", + "cooling_type", + "subcategory", + "start_date", + "end_date", + "heat_cap_ft", + "heat_cap_fflow", + "heat_eir_ft", + "heat_eir_fflow", + "heat_plf_fplr", + ] + + for f in str_expected: + if record.get(f): + assert isinstance( + record[f], str + ), f"{f} requires to be a string, instead got {record[f]}" + + float_expected = [ + "minimum_capacity", + "maximum_capacity", + "minimum_heating_seasonal_performance_factor", + "minimum_coefficient_of_performance_heating", + "minimum_energy_efficiency_ratio", + "pthp_cop_coefficient_1", + "pthp_cop_coefficient_2", + ] + + for f in float_expected: + if record.get(f): + assert is_float( + record.get(f) + ), f"{f} requires to be numeric data type, instead got {record[f]}" + + def _preprocess_record(self, record): + """ + + :param record: dict + :return: + """ + + return ( + getattr_either("template", record), + getattr_either("cooling_type", record), + getattr_either("subcategory", record), + getattr_either("minimum_capacity", record), + getattr_either("maximum_capacity", record), + getattr_either("start_date", record), + getattr_either("end_date", record), + getattr_either("minimum_heating_seasonal_performance_factor", record), + getattr_either("minimum_coefficient_of_performance_heating", record), + getattr_either("minimum_energy_efficiency_ratio", record), + getattr_either("pthp_cop_coefficient_1", record), + getattr_either("pthp_cop_coefficient_2", record), + getattr_either("heat_cap_ft", record), + getattr_either("heat_cap_fflow", record), + getattr_either("heat_eir_ft", record), + getattr_either("heat_eir_fflow", record), + getattr_either("heat_plf_fplr", record), + getattr_either("annotation", record), + ) + + def _get_create_table_query(self): + return CREATE_HVAC_REQUIREMENT_HEAT_PUMP_HEATING_TABLE % self.data_table_name + + def _get_insert_record_query(self): + return INSERT_A_HEAT_PUMP_HEATING_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_heating_90_1.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_heating_90_1.py new file mode 100644 index 0000000000..884002086b --- /dev/null +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_heating_90_1.py @@ -0,0 +1,17 @@ +import sqlite3 + +from database_tables.hvac_minimum_requirement_heat_pump_heating import ( + HVACMinimumRequirementHeatPumpHeating, +) + +TABLE_NAME = "hvac_minimum_requirement_heat_pump_heating_90_1" + + +class HVACMinimumRequirementHeatPumpHeating901Table( + HVACMinimumRequirementHeatPumpHeating +): + def __init__(self): + super(HVACMinimumRequirementHeatPumpHeating901Table, self).__init__( + table_name=TABLE_NAME, + initial_data_directory=f"initial_data/{TABLE_NAME}", + ) diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_rejection.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_rejection.py new file mode 100644 index 0000000000..51cc7a1759 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_rejection.py @@ -0,0 +1,107 @@ +from database_engine.database import DBOperation +from database_engine.database_util import is_float, getattr_either + +RECORD_HELP = """ +Must provide a tuple that contains: +template: TEXT +equipment_type: TEXT +fan_type: TEXT +start_date: TEXT +end_date: TEXT +minimum_performance_gpm_per_hp: NUMERIC +annotation: TEXT (optional) +""" + +CREATE_HVAC_REQUIREMENT_HEAT_REJECTION_TABLE = """ +CREATE TABLE IF NOT EXISTS %s +(id INTEGER PRIMARY KEY, +template TEXT NOT NULL, +equipment_type TEXT NOT NULL, +fan_type TEXT NOT NULL, +start_date TEXT NOT NULL, +end_date TEXT NOT NULL, +minimum_performance_gpm_per_hp NUMERIC NOT NULL, +annotation TEXT); +""" + +INSERT_A_HEAT_REJECTION_RECORD = """ + INSERT INTO %s ( +template, +equipment_type, +fan_type, +start_date, +end_date, +minimum_performance_gpm_per_hp, +annotation +) +VALUES (?, ?, ?, ? ,? , ?, ?); +""" + +RECORD_TEMPLATE = { + "template": "", + "equipment_type": "", + "fan_type": "", + "start_date": "", + "end_date": "", + "minimum_performance_gpm_per_hp": 0.0, + "annotation": "", +} + + +class HVACMinimumRequirementHeatRejection(DBOperation): + def __init__(self, table_name, initial_data_directory): + super(HVACMinimumRequirementHeatRejection, self).__init__( + table_name=table_name, + record_template=RECORD_TEMPLATE, + initial_data_directory=initial_data_directory, + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def validate_record_datatype(self, record): + str_expected = [ + "template", + "equipment_type", + "start_date", + "end_date", + "fan_type", + ] + + for f in str_expected: + if record.get(f): + assert isinstance( + record[f], str + ), f"{f} requires to be a string, instead got {record[f]}" + + if record.get("minimum_performance_gpm_per_hp"): + assert is_float( + record.get("minimum_performance_gpm_per_hp") + ), f"minimum_performance_gpm_per_hp requires to be numeric data type, instead got {record['minimum_performance_gpm_per_hp']}" + + def _preprocess_record(self, record): + """ + + :param record: dict + :return: + """ + + return ( + getattr_either("template", record), + getattr_either("equipment_type", record), + getattr_either("fan_type", record), + getattr_either("start_date", record), + getattr_either("end_date", record), + getattr_either("minimum_performance_gpm_per_hp", record), + getattr_either("annotation", record), + ) + + def _get_create_table_query(self): + return CREATE_HVAC_REQUIREMENT_HEAT_REJECTION_TABLE % self.data_table_name + + def _get_insert_record_query(self): + return INSERT_A_HEAT_REJECTION_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_rejection_90_1.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_rejection_90_1.py new file mode 100644 index 0000000000..43a1563e96 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_rejection_90_1.py @@ -0,0 +1,15 @@ +import sqlite3 + +from database_tables.hvac_minimum_requirement_heat_rejection import ( + HVACMinimumRequirementHeatRejection, +) + +TABLE_NAME = "hvac_minimum_requirement_heat_rejection_90_1" + + +class HVACMinimumRequirementHeatRejection901Table(HVACMinimumRequirementHeatRejection): + def __init__(self): + super(HVACMinimumRequirementHeatRejection901Table, self).__init__( + table_name=TABLE_NAME, + initial_data_directory=f"initial_data/{TABLE_NAME}", + ) diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_motors.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_motors.py new file mode 100644 index 0000000000..bbccd02722 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_motors.py @@ -0,0 +1,118 @@ +from database_engine.database import DBOperation +from database_engine.database_util import is_float, getattr_either + +RECORD_HELP = """ +Must provide a tuple that contains: +template: TEXT +number_of_poles: NUMERIC +type: TEXT +synchronous_speed: TEXT +minimum_capacity: NUMERIC +maximum_capacity: NUMERIC +nominal_full_load_efficiency: NUMERIC +annotation: TEXT (optional) +""" + +CREATE_HVAC_REQUIREMENT_MOTORS_TABLE = """ +CREATE TABLE IF NOT EXISTS %s +(id INTEGER PRIMARY KEY, +template TEXT NOT NULL, +number_of_poles NUMERIC, +type TEXT NOT NULL, +synchronous_speed NUMERIC NOT NULL, +minimum_capacity NUMERIC, +maximum_capacity NUMERIC NOT NULL, +nominal_full_load_efficiency NUMERIC NOT NULL, +annotation TEXT); +""" + +INSERT_A_MOTOR_RECORD = """ + INSERT INTO %s ( +template, +number_of_poles, +type, +synchronous_speed, +minimum_capacity, +maximum_capacity, +nominal_full_load_efficiency, +annotation +) +VALUES (?, ?, ?, ? , ?, ?, ?, ?); +""" + +RECORD_TEMPLATE = { + "template": "", + "number_of_poles": 0.0, + "type": "", + "synchronous_speed": 0.0, + "minimum_capacity": 0.0, + "maximum_capacity": 0.0, + "nominal_full_load_efficiency": 0.0, + "annotation": "", +} + + +class HVACMinimumRequirementMotors(DBOperation): + def __init__(self, table_name, initial_data_directory): + super(HVACMinimumRequirementMotors, self).__init__( + table_name=table_name, + record_template=RECORD_TEMPLATE, + initial_data_directory=initial_data_directory, + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def validate_record_datatype(self, record): + str_expected = [ + "template", + "type", + ] + + for f in str_expected: + if record.get(f): + assert isinstance( + record[f], str + ), f"{f} requires to be a string, instead got {record[f]}" + + float_expected = [ + "number_of_poles", + "synchronous_speed", + "minimum_capacity", + "maximum_capacity", + "nominal_full_load_efficiency", + ] + + for f in float_expected: + if record.get(f): + assert is_float( + record.get(f) + ), f"{f} requires to be numeric data type, instead got {record[f]}" + + def _preprocess_record(self, record): + """ + + :param record: dict + :return: + """ + + return ( + getattr_either("template", record), + getattr_either("number_of_poles", record), + getattr_either("type", record), + getattr_either("synchronous_speed", record), + getattr_either("minimum_capacity", record), + getattr_either("maximum_capacity", record), + getattr_either("nominal_full_load_efficiency", record), + getattr_either("annotation", record), + ) + + def _get_create_table_query(self): + return CREATE_HVAC_REQUIREMENT_MOTORS_TABLE % self.data_table_name + + def _get_insert_record_query(self): + return INSERT_A_MOTOR_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_motors_90_1.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_motors_90_1.py new file mode 100644 index 0000000000..c083f45e4f --- /dev/null +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_motors_90_1.py @@ -0,0 +1,13 @@ +import sqlite3 + +from database_tables.hvac_minimum_requirement_motors import HVACMinimumRequirementMotors + +TABLE_NAME = "hvac_minimum_requirement_motors_90_1" + + +class HVACMinimumRequirementMotors901Table(HVACMinimumRequirementMotors): + def __init__(self): + super(HVACMinimumRequirementMotors901Table, self).__init__( + table_name=TABLE_NAME, + initial_data_directory=f"initial_data/{TABLE_NAME}", + ) diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_unitary_air_conditioners.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_unitary_air_conditioners.py new file mode 100644 index 0000000000..54afde0efe --- /dev/null +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_unitary_air_conditioners.py @@ -0,0 +1,197 @@ +from database_engine.database import DBOperation +from database_engine.database_util import is_float, getattr_either + +RECORD_HELP = """ +Must provide a tuple that contains: +template: TEXT +cooling_type: TEXT +heating_type: TEXT +subcategory: TEXT +minimum_capacity: NUMERIC +maximum_capacity: NUMERIC +start_date: TEXT +end_date: TEXT +minimum_seasonal_efficiency: NUMERIC +minimum_energy_efficiency_ratio: NUMERIC +minimum_integrated_part_load_value: NUMERIC +minimum_integrated_energy_efficiency_ratio: NUMERIC +ptac_eer_coefficient_1: NUMERIC +ptac_eer_coefficient_2: NUMERIC +minimum_scop: NUMERIC +cool_cap_ft: TEXT +cool_cap_fflow: TEXT +cool_eir_ft: TEXT +cool_eir_fflow: TEXT +cool_plf_fplr: TEXT +annotation: TEXT (optional) +""" + +CREATE_HVAC_REQUIREMENT_UNITARY_AIR_CONDITIONERS_TABLE = """ +CREATE TABLE IF NOT EXISTS %s +(id INTEGER PRIMARY KEY, +template TEXT NOT NULL, +cooling_type TEXT NOT NULL, +heating_type TEXT NOT NULL, +subcategory TEXT NOT NULL, +minimum_capacity NUMERIC, +maximum_capacity NUMERIC, +start_date TEXT, +end_date TEXT, +minimum_seasonal_efficiency NUMERIC, +minimum_energy_efficiency_ratio NUMERIC, +minimum_integrated_part_load_value NUMERIC, +minimum_integrated_energy_efficiency_ratio NUMERIC, +ptac_eer_coefficient_1 NUMERIC, +ptac_eer_coefficient_2 NUMERIC, +minimum_scop NUMERIC, +cool_cap_ft TEXT, +cool_cap_fflow TEXT, +cool_eir_ft TEXT, +cool_eir_fflow TEXT, +cool_plf_fplr TEXT, +annotation TEXT); +""" + +INSERT_A_UNITARY_AIR_CONDITIONERS_RECORD = """ + INSERT INTO %s ( +template, +cooling_type, +heating_type, +subcategory, +minimum_capacity, +maximum_capacity, +start_date, +end_date, +minimum_seasonal_efficiency, +minimum_energy_efficiency_ratio, +minimum_integrated_part_load_value, +minimum_integrated_energy_efficiency_ratio, +ptac_eer_coefficient_1, +ptac_eer_coefficient_2, +minimum_scop, +cool_cap_ft, +cool_cap_fflow, +cool_eir_ft, +cool_eir_fflow, +cool_plf_fplr, +annotation +) +VALUES (?, ?, ?, ? ,? , ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?); +""" + +RECORD_TEMPLATE = { + "template": "", + "cooling_type": "", + "heating_type": "", + "subcategory": "", + "minimum_capacity": 0.0, + "maximum_capacity": 0.0, + "start_date": "", + "end_date": "", + "minimum_seasonal_efficiency": 0.0, + "minimum_energy_efficiency_ratio": 0.0, + "minimum_integrated_part_load_value": 0.0, + "minimum_integrated_energy_efficiency_ratio": 0.0, + "ptac_eer_coefficient_1": 0.0, + "ptac_eer_coefficient_2": 0.0, + "minimum_scop": 0.0, + "cool_cap_ft": "", + "cool_cap_fflow": "", + "cool_eir_ft": "", + "cool_eir_fflow": "", + "cool_plf_fplr": "", + "annotation": "", +} + + +class HVACMinimumRequirementUnitaryAirConditioners(DBOperation): + def __init__(self, table_name, initial_data_directory): + super(HVACMinimumRequirementUnitaryAirConditioners, self).__init__( + table_name=table_name, + record_template=RECORD_TEMPLATE, + initial_data_directory=initial_data_directory, + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def validate_record_datatype(self, record): + str_expected = [ + "template", + "cooling_type", + "start_date", + "end_date", + "cool_cap_ft", + "cool_cap_fflow", + "cool_eir_ft", + "cool_eir_fflow", + "cool_plf_fplr", + ] + + for f in str_expected: + if record.get(f): + assert isinstance( + record[f], str + ), f"{f} requires to be a string, instead got {record[f]}" + + float_expected = [ + "minimum_capacity", + "maximum_capacity", + "minimum_seasonal_efficiency", + "minimum_energy_efficiency_ratio", + "minimum_integrated_part_load_value", + "minimum_integrated_energy_efficiency_ratio", + "ptac_eer_coefficient_1", + "ptac_eer_coefficient_2", + "minimum_scop", + ] + + for f in float_expected: + if record.get(f): + assert is_float( + record.get(f) + ), f"{f} requires to be numeric data type, instead got {record[f]}" + + def _preprocess_record(self, record): + """ + + :param record: dict + :return: + """ + + return ( + getattr_either("template", record), + getattr_either("cooling_type", record), + getattr_either("heating_type", record), + getattr_either("subcategory", record), + getattr_either("minimum_capacity", record), + getattr_either("maximum_capacity", record), + getattr_either("start_date", record), + getattr_either("end_date", record), + getattr_either("minimum_seasonal_efficiency", record), + getattr_either("minimum_energy_efficiency_ratio", record), + getattr_either("minimum_integrated_part_load_value", record), + getattr_either("minimum_integrated_energy_efficiency_ratio", record), + getattr_either("ptac_eer_coefficient_1", record), + getattr_either("ptac_eer_coefficient_2", record), + getattr_either("minimum_scop", record), + getattr_either("cool_cap_ft", record), + getattr_either("cool_cap_fflow", record), + getattr_either("cool_eir_ft", record), + getattr_either("cool_eir_fflow", record), + getattr_either("cool_plf_fplr", record), + getattr_either("annotation", record), + ) + + def _get_create_table_query(self): + return ( + CREATE_HVAC_REQUIREMENT_UNITARY_AIR_CONDITIONERS_TABLE + % self.data_table_name + ) + + def _get_insert_record_query(self): + return INSERT_A_UNITARY_AIR_CONDITIONERS_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_unitary_air_conditioners_90_1.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_unitary_air_conditioners_90_1.py new file mode 100644 index 0000000000..98372cfe00 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_unitary_air_conditioners_90_1.py @@ -0,0 +1,17 @@ +import sqlite3 + +from database_tables.hvac_minimum_requirement_unitary_air_conditioners import ( + HVACMinimumRequirementUnitaryAirConditioners, +) + +TABLE_NAME = "hvac_minimum_requirement_unitary_air_conditioners_90_1" + + +class HVACMinimumRequirementUnitaryAirConditioners901Table( + HVACMinimumRequirementUnitaryAirConditioners +): + def __init__(self): + super(HVACMinimumRequirementUnitaryAirConditioners901Table, self).__init__( + table_name=TABLE_NAME, + initial_data_directory=f"initial_data/{TABLE_NAME}", + ) diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_heaters.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_heaters.py new file mode 100644 index 0000000000..e413e0f5ed --- /dev/null +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_heaters.py @@ -0,0 +1,160 @@ +from database_engine.database import DBOperation +from database_engine.database_util import is_float, getattr_either + +RECORD_HELP = """ +Must provide a tuple that contains: +template: TEXT +fuel_type: TEXT +minimum_capacity: NUMERIC +maximum_capacity: NUMERIC +start_date: TEXT +end_date: TEXT +energy_factor_base: NUMERIC +energy_factor_volume_derate: NUMERIC +standby_loss_base: NUMERIC +standby_loss_capacity_allowance: NUMERIC +standby_loss_volume_allowance: NUMERIC +hourly_loss_base: NUMERIC +hourly_loss_volume_allowance: NUMERIC +thermal_efficiency: NUMERIC +annotation: TEXT (optional) +""" + +CREATE_HVAC_REQUIREMENT_WATER_HEATERS_TABLE = """ +CREATE TABLE IF NOT EXISTS %s +(id INTEGER PRIMARY KEY, +template TEXT NOT NULL, +fuel_type TEXT NOT NULL, +minimum_capacity NUMERIC, +maximum_capacity NUMERIC, +start_date TEXT NOT NULL, +end_date TEXT NOT NULL, +energy_factor_base NUMERIC, +energy_factor_volume_derate NUMERIC, +standby_loss_base NUMERIC, +standby_loss_capacity_allowance NUMERIC, +standby_loss_volume_allowance NUMERIC, +hourly_loss_base NUMERIC, +hourly_loss_volume_allowance NUMERIC, +thermal_efficiency NUMERIC, +annotation TEXT); +""" + +INSERT_A_WATER_HEATER_RECORD = """ + INSERT INTO %s ( +template, +fuel_type, +minimum_capacity, +maximum_capacity, +start_date, +end_date, +energy_factor_base, +energy_factor_volume_derate, +standby_loss_base, +standby_loss_capacity_allowance, +standby_loss_volume_allowance, +hourly_loss_base, +hourly_loss_volume_allowance, +thermal_efficiency, +annotation +) +VALUES (?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?); +""" + +RECORD_TEMPLATE = { + "template": "", + "fuel_type": "", + "minimum_capacity": 0.0, + "maximum_capacity": 0.0, + "start_date": "", + "end_date": "", + "energy_factor_base,": 0.0, + "energy_factor_volume_derate,": 0.0, + "standby_loss_base,": 0.0, + "standby_loss_capacity_allowance,": 0.0, + "standby_loss_volume_allowance,": 0.0, + "hourly_loss_base,": 0.0, + "hourly_loss_volume_allowance,": 0.0, + "thermal_efficiency,": 0.0, + "annotation": "", +} + + +class HVACMinimumRequirementWaterHeaters(DBOperation): + def __init__(self, table_name, initial_data_directory): + super(HVACMinimumRequirementWaterHeaters, self).__init__( + table_name=table_name, + record_template=RECORD_TEMPLATE, + initial_data_directory=initial_data_directory, + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def validate_record_datatype(self, record): + str_expected = [ + "template", + "fuel_type", + "start_date", + "end_date", + ] + + for f in str_expected: + if record.get(f): + assert isinstance( + record[f], str + ), f"{f} requires to be a string, instead got {record[f]}" + + float_expected = [ + "minimum_capacity", + "maximum_capacity", + "energy_factor_base", + "energy_factor_volume_derate", + "standby_loss_base", + "standby_loss_capacity_allowance", + "standby_loss_volume_allowance", + "hourly_loss_base", + "hourly_loss_volume_allowance", + "thermal_efficiency", + ] + + for f in float_expected: + if record.get(f): + assert is_float( + record.get(f) + ), f"{f} requires to be numeric data type, instead got {record[f]}" + + def _preprocess_record(self, record): + """ + + :param record: dict + :return: + """ + + return ( + getattr_either("template", record), + getattr_either("fuel_type", record), + getattr_either("minimum_capacity", record), + getattr_either("maximum_capacity", record), + getattr_either("start_date", record), + getattr_either("end_date", record), + getattr_either("energy_factor_base", record), + getattr_either("energy_factor_volume_derate", record), + getattr_either("standby_loss_base", record), + getattr_either("standby_loss_capacity_allowance", record), + getattr_either("standby_loss_volume_allowance", record), + getattr_either("hourly_loss_base", record), + getattr_either("hourly_loss_volume_allowance", record), + getattr_either("thermal_efficiency", record), + getattr_either("annotation", record), + ) + + def _get_create_table_query(self): + return CREATE_HVAC_REQUIREMENT_WATER_HEATERS_TABLE % self.data_table_name + + def _get_insert_record_query(self): + return INSERT_A_WATER_HEATER_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_heaters_90_1.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_heaters_90_1.py new file mode 100644 index 0000000000..5999f58e3a --- /dev/null +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_heaters_90_1.py @@ -0,0 +1,15 @@ +import sqlite3 + +from database_tables.hvac_minimum_requirement_water_heaters import ( + HVACMinimumRequirementWaterHeaters, +) + +TABLE_NAME = "hvac_minimum_requirement_water_heaters_90_1" + + +class HVACMinimumRequirementWaterHeaters901Table(HVACMinimumRequirementWaterHeaters): + def __init__(self): + super(HVACMinimumRequirementWaterHeaters901Table, self).__init__( + table_name=TABLE_NAME, + initial_data_directory=f"initial_data/{TABLE_NAME}", + ) diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_cooling.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_cooling.py new file mode 100644 index 0000000000..643cb56914 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_cooling.py @@ -0,0 +1,128 @@ +from database_engine.database import DBOperation +from database_engine.database_util import is_float, getattr_either + +RECORD_HELP = """ +Must provide a tuple that contains: +template: TEXT +minimum_capacity: NUMERIC +maximum_capacity: NUMERIC +start_date: TEXT +end_date: TEXT +minimum_full_load_efficiency: NUMERIC +annotation: TEXT (optional) +""" + +CREATE_HVAC_REQUIREMENT_WATER_SOURCE_HEAT_PUMPS_COOLING_TABLE = """ +CREATE TABLE IF NOT EXISTS %s +(id INTEGER PRIMARY KEY, +template TEXT NOT NULL, +minimum_capacity NUMERIC, +maximum_capacity NUMERIC, +start_date TEXT NOT NULL, +end_date TEXT NOT NULL, +minimum_full_load_efficiency NUMERIC, +annotation TEXT); +""" + +INSERT_A_WATER_SOURCE_HEAT_PUMP_RECORD = """ + INSERT INTO %s ( +template, +minimum_capacity, +maximum_capacity, +start_date, +end_date, +minimum_full_load_efficiency, +annotation +) +VALUES (?, ?, ?, ? ,? , ?, ?); +""" + +RECORD_TEMPLATE = { + "template": "", + "minimum_capacity": 0.0, + "maximum_capacity": 0.0, + "start_date": "", + "end_date": "", + "minimum_full_load_efficiency": 0.0, + "annotation": "", +} + + +class HVACMinimumRequirementWaterSourceHeatPumpsCooling(DBOperation): + def __init__(self, table_name, initial_data_directory): + super(HVACMinimumRequirementWaterSourceHeatPumpsCooling, self).__init__( + table_name=table_name, + record_template=RECORD_TEMPLATE, + initial_data_directory=initial_data_directory, + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def validate_record_datatype(self, record): + str_expected = [ + "template", + "start_date", + "end_date", + ] + + for f in str_expected: + if record.get(f): + assert isinstance( + record[f], str + ), f"{f} requires to be a string, instead got {record[f]}" + + float_expected = [ + "minimum_capacity", + "maximum_capacity", + "minimum_full_load_efficiency", + ] + + for f in float_expected: + if record.get(f): + assert is_float( + record.get(f) + ), f"{f} requires to be numeric data type, instead got {record[f]}" + + if record.get("minimum_capacity"): + assert is_float( + record.get("minimum_capacity") + ), f"minimum_capacity requires to be numeric data type, instead got {record['minimum_capacity']}" + if record.get("maximum_capacity"): + assert is_float( + record.get("maximum_capacity") + ), f"maximum_capacity requires to be numeric data type, instead got {record['minimum_capacity']}" + if record.get(""): + assert is_float( + record.get("minimum_full_load_efficiency") + ), f"minimum_full_load_efficiency requires to be numeric data type, instead got {record['minimum_full_load_efficiency']}" + + def _preprocess_record(self, record): + """ + + :param record: dict + :return: + """ + + return ( + getattr_either("template", record), + getattr_either("minimum_capacity", record), + getattr_either("maximum_capacity", record), + getattr_either("start_date", record), + getattr_either("end_date", record), + getattr_either("minimum_full_load_efficiency", record), + getattr_either("annotation", record), + ) + + def _get_create_table_query(self): + return ( + CREATE_HVAC_REQUIREMENT_WATER_SOURCE_HEAT_PUMPS_COOLING_TABLE + % self.data_table_name + ) + + def _get_insert_record_query(self): + return INSERT_A_WATER_SOURCE_HEAT_PUMP_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1.py new file mode 100644 index 0000000000..b923fc7008 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1.py @@ -0,0 +1,17 @@ +import sqlite3 + +from database_tables.hvac_minimum_requirement_water_source_heat_pumps_cooling import ( + HVACMinimumRequirementWaterSourceHeatPumpsCooling, +) + +TABLE_NAME = "hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1" + + +class HVACMinimumRequirementWaterSourceHeatPumpsCooling901Table( + HVACMinimumRequirementWaterSourceHeatPumpsCooling +): + def __init__(self): + super(HVACMinimumRequirementWaterSourceHeatPumpsCooling901Table, self).__init__( + table_name=TABLE_NAME, + initial_data_directory=f"initial_data/{TABLE_NAME}", + ) diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_heating.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_heating.py new file mode 100644 index 0000000000..e5a5fd097e --- /dev/null +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_heating.py @@ -0,0 +1,115 @@ +from database_engine.database import DBOperation +from database_engine.database_util import is_float, getattr_either + +RECORD_HELP = """ +Must provide a tuple that contains: +template: TEXT +minimum_capacity: NUMERIC +maximum_capacity: NUMERIC +start_date: TEXT +end_date: TEXT +minimum_coefficient_of_performance: NUMERIC +annotation: TEXT (optional) +""" + +CREATE_HVAC_REQUIREMENT_WATER_SOURCE_HEAT_PUMPS_HEATING_TABLE = """ +CREATE TABLE IF NOT EXISTS %s +(id INTEGER PRIMARY KEY, +template TEXT NOT NULL, +minimum_capacity NUMERIC, +maximum_capacity NUMERIC, +start_date TEXT NOT NULL, +end_date TEXT NOT NULL, +minimum_coefficient_of_performance NUMERIC, +annotation TEXT); +""" + +INSERT_A_WATER_SOURCE_HEAT_PUMP_RECORD = """ + INSERT INTO %s ( +template, +minimum_capacity, +maximum_capacity, +start_date, +end_date, +minimum_coefficient_of_performance, +annotation +) +VALUES (?, ?, ?, ? ,? , ?, ?); +""" + +RECORD_TEMPLATE = { + "template": "", + "minimum_capacity": 0.0, + "maximum_capacity": 0.0, + "start_date": "", + "end_date": "", + "minimum_coefficient_of_performance": 0.0, + "annotation": "", +} + + +class HVACMinimumRequirementWaterSourceHeatPumpsHeating(DBOperation): + def __init__(self, table_name, initial_data_directory): + super(HVACMinimumRequirementWaterSourceHeatPumpsHeating, self).__init__( + table_name=table_name, + record_template=RECORD_TEMPLATE, + initial_data_directory=initial_data_directory, + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def validate_record_datatype(self, record): + str_expected = [ + "template", + "start_date", + "end_date", + ] + + for f in str_expected: + if record.get(f): + assert isinstance( + record[f], str + ), f"{f} requires to be a string, instead got {record[f]}" + + float_expected = [ + "minimum_capacity", + "maximum_capacity", + "minimum_coefficient_of_performance", + ] + + for f in float_expected: + if record.get(f): + assert is_float( + record.get(f) + ), f"{f} requires to be numeric data type, instead got {record[f]}" + + def _preprocess_record(self, record): + """ + + :param record: dict + :return: + """ + + return ( + getattr_either("template", record), + getattr_either("minimum_capacity", record), + getattr_either("maximum_capacity", record), + getattr_either("start_date", record), + getattr_either("end_date", record), + getattr_either("minimum_coefficient_of_performance", record), + getattr_either("annotation", record), + ) + + def _get_create_table_query(self): + return ( + CREATE_HVAC_REQUIREMENT_WATER_SOURCE_HEAT_PUMPS_HEATING_TABLE + % self.data_table_name + ) + + def _get_insert_record_query(self): + return INSERT_A_WATER_SOURCE_HEAT_PUMP_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_heating_90_1.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_heating_90_1.py new file mode 100644 index 0000000000..6d57f5a53e --- /dev/null +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_heating_90_1.py @@ -0,0 +1,17 @@ +import sqlite3 + +from database_tables.hvac_minimum_requirement_water_source_heat_pumps_heating import ( + HVACMinimumRequirementWaterSourceHeatPumpsHeating, +) + +TABLE_NAME = "hvac_minimum_requirement_water_source_heat_pumps_heating_90_1" + + +class HVACMinimumRequirementWaterSourceHeatPumpsHeating901Table( + HVACMinimumRequirementWaterSourceHeatPumpsHeating +): + def __init__(self): + super(HVACMinimumRequirementWaterSourceHeatPumpsHeating901Table, self).__init__( + table_name=TABLE_NAME, + initial_data_directory=f"initial_data/{TABLE_NAME}", + ) diff --git a/data/openstudio_standards_data/database_tables/level_1_space_types.py b/data/openstudio_standards_data/database_tables/level_1_space_types.py new file mode 100644 index 0000000000..823fa642e4 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/level_1_space_types.py @@ -0,0 +1,76 @@ +from database_engine.database import DBOperation +from database_engine.database_util import getattr_either + +TABLE_NAME = "level_1_space_types" + +RECORD_HELP = """ +Must provide a dict that contains following key value pairs: +space_type_name: TEXT +lighting_space_type_name: TEXT +ventilation_space_type_name: TEXT +electric_equipment_space_type_name: TEXT +""" + +CREATE_level_1_space_types = f""" +CREATE TABLE IF NOT EXISTS {TABLE_NAME} +(id INTEGER PRIMARY KEY, +space_type_name TEXT NOT NULL, +lighting_space_type_name TEXT, +ventilation_space_type_name TEXT, +electric_equipment_space_type_name TEXT, +FOREIGN KEY(lighting_space_type_name) REFERENCES support_lighting_space_type_name_tags(lighting_space_type_name) +FOREIGN KEY(ventilation_space_type_name) REFERENCES support_ventilation_space_type_name_tags(ventilation_space_type_name) +FOREIGN KEY(electric_equipment_space_type_name) REFERENCES support_electric_equipment_space_type_name_tags(support_electric_equipment_space_type_name_tags) +); +""" + +INSERT_level_1_space_types = f""" + INSERT INTO {TABLE_NAME} + (space_type_name, lighting_space_type_name, ventilation_space_type_name, electric_equipment_space_type_name) + VALUES (?, ?, ?, ?); +""" + + +RECORD_TEMPLATE = { + "space_type_name": "", + "lighting_space_type_name": "", + "ventilation_space_type_name": "", + "electric_equipment_space_type_name": "", +} + + +class GeneralBuildingSpaceTypeTable(DBOperation): + def __init__(self): + super(GeneralBuildingSpaceTypeTable, self).__init__( + table_name=TABLE_NAME, + record_template=RECORD_TEMPLATE, + initial_data_directory=f"initial_data/{TABLE_NAME}", + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def _preprocess_record(self, record): + """ + + :param record: dict + :return: + """ + assert bool(record.get("space_type_name")), "Missing space type" + + return ( + getattr_either("space_type_name", record), + getattr_either("lighting_space_type_name", record), + getattr_either("ventilation_space_type_name", record), + getattr_either("electric_equipment_space_type_name", record), + ) + + def _get_create_table_query(self): + return CREATE_level_1_space_types + + def _get_insert_record_query(self): + return INSERT_level_1_space_types diff --git a/data/openstudio_standards_data/database_tables/level_2_electric_equipment.py b/data/openstudio_standards_data/database_tables/level_2_electric_equipment.py new file mode 100644 index 0000000000..c753772976 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/level_2_electric_equipment.py @@ -0,0 +1,95 @@ +import sqlite3 + +from database_engine.database import DBOperation +from database_engine.database_util import is_float, getattr_either + +TABLE_NAME = "level_2_electric_equipment" + + +RECORD_HELP = """ +Must provide a tuple that contains: +electric_equipment_space_type_name: TEXT +electric_equipment_minimum_epd: REAL +electric_equipment_average_epd: REAL +electric_equipment_median_epd: REAL +electric_equipment_maximum_epd: REAL +electric_equipment_epd_unit: TEXT +""" + +CREATE_level_2_electric_equipment = """ +CREATE TABLE IF NOT EXISTS %s +(id INTEGER PRIMARY KEY, +electric_equipment_space_type_name TEXT NOT NULL, +electric_equipment_minimum_epd NUMERIC, +electric_equipment_average_epd NUMERIC, +electric_equipment_median_epd NUMERIC, +electric_equipment_maximum_epd NUMERIC, +electric_equipment_epd_unit TEXT); +""" + +INSERT_EQUIP_LOAD_RECORD = """ + INSERT INTO %s + (electric_equipment_space_type_name, electric_equipment_minimum_epd, electric_equipment_average_epd, electric_equipment_median_epd, electric_equipment_maximum_epd, electric_equipment_epd_unit) + VALUES (?, ?, ?, ? , ? ,?); +""" + +RECORD_TEMPLATE = { + "electric_equipment_space_type_name": "", + "electric_equipment_minimum_epd": "", + "electric_equipment_average_epd": "", + "electric_equipment_median_epd": "", + "electric_equipment_maximum_epd": "", + "electric_equipment_epd_unit": "W/ft2", +} + + +class EquipLoadTable(DBOperation): + def __init__(self): + super(EquipLoadTable, self).__init__( + table_name=TABLE_NAME, + record_template=RECORD_TEMPLATE, + initial_data_directory=f"initial_data/{TABLE_NAME}", + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def validate_record_datatype(self, record): + float_expected = [ + "electric_equipment_minimum_epd", + "electric_equipment_average_epd", + "electric_equipment_median_epd", + "electric_equipment_maximum_epd", + ] + + for f in float_expected: + if record.get(f): + assert is_float( + record.get(f) + ), f"{f} requires to be numeric data type, instead got {record[f]}" + + def _preprocess_record(self, record): + """ + + :param record: dictionary + :return: + """ + record_tuple = ( + getattr_either("electric_equipment_space_type_name", record), + getattr_either("electric_equipment_minimum_epd", record), + getattr_either("electric_equipment_average_epd", record), + getattr_either("electric_equipment_median_epd", record), + getattr_either("electric_equipment_maximum_epd", record), + getattr_either("electric_equipment_epd_unit", record, ""), + ) + return record_tuple + + def _get_create_table_query(self): + return CREATE_level_2_electric_equipment % self.data_table_name + + def _get_insert_record_query(self): + return INSERT_EQUIP_LOAD_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py b/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py new file mode 100644 index 0000000000..1e0fd87447 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py @@ -0,0 +1,69 @@ +from database_engine.database import DBOperation +from database_engine.database_util import getattr_either + +TABLE_NAME = "level_2_lighting_space_types" + +RECORD_HELP = """ +Must provide a tuple that contains: +lighting_space_type_name: TEXT (unique) +level_3_lighting_definition_table: TEXT +level_3_lighting_defintion_id: id from level_3_lighting_definition index +""" + +LIGHT_SUBSPACE_TABLE = """ +CREATE TABLE IF NOT EXISTS level_2_lighting_space_types +(id INTEGER PRIMARY KEY, +lighting_space_type_name TEXT NOT NULL, +level_3_lighting_definition_table TEXT NOT NULL, +level_3_lighting_defintion_id INTEGER NOT NULL, +FOREIGN KEY(lighting_space_type_name) REFERENCES support_lighting_space_type_name_tags(lighting_space_type_name) +); +""" + +INSERT_LIGHT_SUBSPACE = f""" + INSERT INTO {TABLE_NAME} + (lighting_space_type_name, level_3_lighting_definition_table, level_3_lighting_defintion_id) + VALUES (?, ?, ?); +""" + +RECORD_TEMPLATE = { + "lighting_space_type_name": "", + "level_3_lighting_definition_table": "", + "level_3_lighting_defintion_id": "", +} + + +class LightSubspaceTable(DBOperation): + def __init__(self): + super(LightSubspaceTable, self).__init__( + table_name=TABLE_NAME, + record_template=RECORD_TEMPLATE, + initial_data_directory=f"initial_data/{TABLE_NAME}", + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def _preprocess_record(self, record): + """ + + :param record: dict + :return: + """ + record_list = ( + getattr_either("lighting_space_type_name", record), + getattr_either("level_3_lighting_definition_table", record), + getattr_either("level_3_lighting_defintion_id", record), + ) + + return record_list + + def _get_create_table_query(self): + return LIGHT_SUBSPACE_TABLE + + def _get_insert_record_query(self): + return INSERT_LIGHT_SUBSPACE diff --git a/data/openstudio_standards_data/database_tables/level_2_ventilation_space_types.py b/data/openstudio_standards_data/database_tables/level_2_ventilation_space_types.py new file mode 100644 index 0000000000..0800386f72 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/level_2_ventilation_space_types.py @@ -0,0 +1,71 @@ +from database_engine.database import DBOperation +from database_engine.database_util import getattr_either + +TABLE_NAME = "level_2_ventilation_space_types" + +RECORD_HELP = """ +Must provide a tuple that contains: +ventilation_space_type_name: TEXT (unique) +level_3_ventilation_definition_table: TEXT +level_3_ventilation_defintion_id: id from level_3_ventilation_definition index +""" + +VENT_SUBSPACE_TABLE = """ +CREATE TABLE IF NOT EXISTS level_2_ventilation_space_types +(id INTEGER PRIMARY KEY, +ventilation_space_type_name TEXT NOT NULL, +level_3_ventilation_definition_table TEXT NOT NULL, +level_3_ventilation_defintion_id INTEGER NOT NULL, +FOREIGN KEY(ventilation_space_type_name) REFERENCES support_ventilation_space_type_name_tags(ventilation_space_type_name) + +); +""" + +INSERT_VENT_SUBSPACE = f""" + INSERT INTO {TABLE_NAME} + (ventilation_space_type_name, level_3_ventilation_definition_table, level_3_ventilation_defintion_id) + VALUES (?, ?, ?); +""" + +RECORD_TEMPLATE = { + "ventilation_space_type_name": "", + "level_3_ventilation_definition_table": "", + "level_3_ventilation_defintion_id": "", +} + + +class VentSubspaceTable(DBOperation): + def __init__(self): + super(VentSubspaceTable, self).__init__( + table_name=TABLE_NAME, + record_template=RECORD_TEMPLATE, + initial_data_directory=f"initial_data/{TABLE_NAME}", + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def _preprocess_record(self, record): + """ + + :param record: dict + :return: + """ + + record_list = ( + getattr_either("ventilation_space_type_name", record), + getattr_either("level_3_ventilation_definition_table", record), + getattr_either("level_3_ventilation_defintion_id", record), + ) + + return record_list + + def _get_create_table_query(self): + return VENT_SUBSPACE_TABLE + + def _get_insert_record_query(self): + return INSERT_VENT_SUBSPACE diff --git a/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2004.py b/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2004.py new file mode 100644 index 0000000000..22d45856a3 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2004.py @@ -0,0 +1,13 @@ +import sqlite3 + +from database_tables.level_3_lighting_90_1_definition import LightDef901 + +TABLE_NAME = "level_3_lighting_90_1_2004" + + +class LightDef9012004Table(LightDef901): + def __init__(self): + super(LightDef9012004Table, self).__init__( + table_name=TABLE_NAME, + initial_data_directory=f"initial_data/{TABLE_NAME}", + ) diff --git a/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2019.py b/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2019.py new file mode 100644 index 0000000000..2e3e5605d7 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2019.py @@ -0,0 +1,12 @@ +import sqlite3 + +from database_tables.level_3_lighting_90_1_definition import LightDef901 + +TABLE_NAME = "level_3_lighting_90_1_2019" + + +class LightDef9012019Table(LightDef901): + def __init__(self): + super(LightDef9012019Table, self).__init__( + table_name=TABLE_NAME, initial_data_directory=f"initial_data/{TABLE_NAME}" + ) diff --git a/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_definition.py b/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_definition.py new file mode 100644 index 0000000000..39260c77d3 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_definition.py @@ -0,0 +1,90 @@ +import sqlite3 + +from database_engine.database import DBOperation +from database_engine.database_util import is_float, getattr_either + +RECORD_HELP = """ +Must provide a tuple that contains: +method: [BA, CS, SS] +lighting_primary_space_type: TEXT +lighting_secondary_space_type: TEXT +lighting_per_area: REAL +lighting_per_area_unit: TEXT +annotation: TEXT (optional) +""" + +CREATE_LIGHT_DEF_90_1_TABLE = """ +CREATE TABLE IF NOT EXISTS %s +(id INTEGER PRIMARY KEY, +method TEXT DEFAULT 'BA' NOT NULL, +lighting_primary_space_type TEXT, +lighting_per_area NUMERIC NOT NULL, +lighting_secondary_space_type TEXT, +lighting_per_area_unit TEXT DEFAULT 'w/ft2' NOT NULL, +annotation TEXT); +""" + +INSERT_A_LIGHT_RECORD = """ + INSERT INTO %s + (method, lighting_primary_space_type, lighting_secondary_space_type, lighting_per_area, lighting_per_area_unit, annotation) + VALUES (?, ?, ?, ? , ? ,?); +""" + +RECORD_TEMPLATE = { + "method": "", + "lighting_primary_space_type": "", + "lighting_secondary_space_type": "", + "lighting_per_area": 0.0, + "lighting_per_area_unit": "W/ft2", + "annotation": "", +} + + +class LightDef901(DBOperation): + def __init__(self, table_name, initial_data_directory): + super(LightDef901, self).__init__( + table_name=table_name, + record_template=RECORD_TEMPLATE, + initial_data_directory=initial_data_directory, + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def validate_record_datatype(self, record): + if record.get("method"): + assert record["method"] in [ + "BA", + "CS", + "SS", + ], f"method is provided with wrong choice value. Available: BA, CS, SS " + if record.get("lighting_per_area"): + assert is_float( + record.get("lighting_per_area") + ), f"lighting_per_area requires to be numeric data type, instead got {record['lighting_per_area']}" + + def _preprocess_record(self, record): + """ + + :param record: dictionary + :return: + """ + record_tuple = ( + getattr_either("method", record), + getattr_either("lighting_primary_space_type", record), + getattr_either("lighting_secondary_space_type", record), + getattr_either("lighting_per_area", record), + getattr_either("lighting_per_area_unit", record, "W/ft2"), + getattr_either("annotation", record, ""), + ) + return record_tuple + + def _get_create_table_query(self): + return CREATE_LIGHT_DEF_90_1_TABLE % self.data_table_name + + def _get_insert_record_query(self): + return INSERT_A_LIGHT_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2004.py b/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2004.py new file mode 100644 index 0000000000..d79e3fa6b4 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2004.py @@ -0,0 +1,13 @@ +import sqlite3 + +from database_tables.level_3_ventilation_62_1_definition import VentDef621 + +TABLE_NAME = "level_3_ventilation_62_1_2004" + + +class VentDef6212004Table(VentDef621): + def __init__(self): + super(VentDef6212004Table, self).__init__( + table_name=TABLE_NAME, + initial_data_directory=f"initial_data/{TABLE_NAME}", + ) diff --git a/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2019.py b/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2019.py new file mode 100644 index 0000000000..3845d46a07 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2019.py @@ -0,0 +1,12 @@ +import sqlite3 + +from database_tables.level_3_ventilation_62_1_definition import VentDef621 + +TABLE_NAME = "level_3_ventilation_62_1_2019" + + +class VentDef6212019Table(VentDef621): + def __init__(self): + super(VentDef6212019Table, self).__init__( + table_name=TABLE_NAME, initial_data_directory=f"initial_data/{TABLE_NAME}" + ) diff --git a/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_definition.py b/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_definition.py new file mode 100644 index 0000000000..633f943aad --- /dev/null +++ b/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_definition.py @@ -0,0 +1,112 @@ +import sqlite3 + +from database_engine.database import DBOperation +from database_engine.database_util import is_float, getattr_either + +RECORD_HELP = """ +Must provide a tuple that contains: +ventilation_primary_space_type: TEXT +ventilation_secondary_space_type: TEXT +ventilation_per_person: NUMERIC +ventilation_per_person_unit: TEXT +ventilation_per_area: NUMERIC +ventilation_per_area_unit: TEXT, +occupancy_per_area: NUMERIC, +occupancy_per_area_unit: TEXT +air_class: INTEGER +os: TEXT +annotation: TEXT (optional) +""" + +CREATE_VENT_DEF_62_1_TABLE = """ +CREATE TABLE IF NOT EXISTS %s +(id INTEGER PRIMARY KEY, +ventilation_primary_space_type TEXT NOT NULL, +ventilation_secondary_space_type TEXT NOT NULL, +ventilation_per_person NUMERIC, +ventilation_per_person_unit TEXT DEFAULT 'cfm/person', +ventilation_per_area NUMERIC, +ventilation_per_area_unit TEXT DEFAULT 'cfm/ft2', +occupancy_per_area NUMERIC, +occupancy_per_area_unit TEXT DEFAULT 'ppl/1000 ft2', +air_class INTEGER, +os TEXT, +annotation TEXT); +""" + +INSERT_A_VENT_RECORD = """ + INSERT INTO %s (ventilation_primary_space_type, +ventilation_secondary_space_type, ventilation_per_person, ventilation_per_person_unit, +ventilation_per_area, ventilation_per_area_unit, occupancy_per_area, occupancy_per_area_unit, air_class, os, annotation) +VALUES (?, ?, ?, ? ,? ,? , ?, ?, ?, ?, ?); +""" + +RECORD_TEMPLATE = { + "ventilation_primary_space_type": "", + "ventilation_secondary_space_type": "", + "ventilation_per_person": 0.0, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.0, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 0.0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 0, + "os": "", + "annotation": "", +} + + +class VentDef621(DBOperation): + def __init__(self, table_name, initial_data_directory): + super(VentDef621, self).__init__( + table_name=table_name, + record_template=RECORD_TEMPLATE, + initial_data_directory=initial_data_directory, + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def validate_record_datatype(self, record): + float_expected = [ + "ventilation_per_person", + "ventilation_per_area", + "occupancy_per_area", + ] + + for f in float_expected: + if record.get(f): + assert is_float( + record.get(f) + ), f"{f} requires to be numeric data type, instead got {record[f]}" + + def _preprocess_record(self, record): + """ + + :param record: dict + :return: + """ + + return ( + getattr_either("ventilation_primary_space_type", record), + getattr_either("ventilation_secondary_space_type", record), + getattr_either("ventilation_per_person", record), + getattr_either("ventilation_per_person_unit", record, "cfm/person"), + getattr_either("ventilation_per_area", record), + getattr_either("ventilation_per_area_unit", record, "cfm/ft2"), + getattr_either("occupancy_per_area", record), + getattr_either("occupancy_per_area_unit", record, "ppl/1000 ft2"), + getattr_either("air_class", record), + getattr_either("os", record), + getattr_either("annotation", record, ""), + ) + + def _get_create_table_query(self): + return CREATE_VENT_DEF_62_1_TABLE % self.data_table_name + + def _get_insert_record_query(self): + return INSERT_A_VENT_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/support_constructions.py b/data/openstudio_standards_data/database_tables/support_constructions.py new file mode 100644 index 0000000000..0dc2d53d18 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/support_constructions.py @@ -0,0 +1,136 @@ +from database_engine.database import DBOperation +from database_engine.database_util import getattr_either + +TABLE_NAME = "support_constructions" + +RECORD_HELP = """ +Must provide a dict that contains following key value pairs: +name: TEXT +intended_surface_type: TEXT +standard_construction_type: TEXT +insulation_layer: TEXT +skylight_framing: TEXT +material_1: TEXT +material_2: TEXT +material_3: TEXT +material_4: TEXT +material_5: TEXT +material_6: TEXT +""" + +CREATE_CONSTRUCTIONS_TABLE = f""" +CREATE TABLE IF NOT EXISTS {TABLE_NAME} +(name TEXT UNIQUE NOT NULL PRIMARY KEY, +intended_surface_type TEXT, +standard_construction_type TEXT, +insulation_layer TEXT, +skylight_framing TEXT, +material_1 TEXT, +material_2 TEXT, +material_3 TEXT, +material_4 TEXT, +material_5 TEXT, +material_6 TEXT, +FOREIGN KEY(material_1) REFERENCES support_materials(name) +FOREIGN KEY(material_2) REFERENCES support_materials(name) +FOREIGN KEY(material_3) REFERENCES support_materials(name) +FOREIGN KEY(material_4) REFERENCES support_materials(name) +FOREIGN KEY(material_5) REFERENCES support_materials(name) +FOREIGN KEY(material_6) REFERENCES support_materials(name) +); +""" + +INSERT_CONSTRUCTION = f""" + INSERT INTO {TABLE_NAME} + (name, +intended_surface_type, +standard_construction_type, +insulation_layer, +skylight_framing, +material_1, +material_2, +material_3, +material_4, +material_5, +material_6) + VALUES (?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?); +""" + + +RECORD_TEMPLATE = { + "name": "", + "intended_surface_type": "", + "standard_construction_type": "", + "insulation_layer": "", + "skylight_framing": "", + "material_1": "", + "material_2": "", + "material_3": "", + "material_4": "", + "material_5": "", + "material_6": "", +} + + +class SupportConstructionsTable(DBOperation): + def __init__(self): + super(SupportConstructionsTable, self).__init__( + table_name=TABLE_NAME, + record_template=RECORD_TEMPLATE, + initial_data_directory=f"initial_data/{TABLE_NAME}", + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def validate_record_datatype(self, record): + str_expected = [ + "name", + "intended_surface_type", + "standard_construction_type", + "insulation_layer", + "skylight_framing", + "material_1", + "material_2", + "material_3", + "material_4", + "material_5", + "material_6", + ] + + for f in str_expected: + if record.get(f): + assert isinstance( + record[f], str + ), f"{f} requires to be a string, instead got {record[f]}" + + def _preprocess_record(self, record): + """ + + :param record: dict + :return: + """ + + return ( + getattr_either("name", record), + getattr_either("intended_surface_type", record), + getattr_either("standard_construction_type", record), + getattr_either("insulation_layer", record), + getattr_either("skylight_framing", record), + getattr_either("material_1", record), + getattr_either("material_2", record), + getattr_either("material_3", record), + getattr_either("material_4", record), + getattr_either("material_5", record), + getattr_either("material_6", record), + ) + + def _get_create_table_query(self): + return CREATE_CONSTRUCTIONS_TABLE + + def _get_insert_record_query(self): + return INSERT_CONSTRUCTION diff --git a/data/openstudio_standards_data/database_tables/support_electric_equipment_space_type_name_tags.py b/data/openstudio_standards_data/database_tables/support_electric_equipment_space_type_name_tags.py new file mode 100644 index 0000000000..c2c4659fe2 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/support_electric_equipment_space_type_name_tags.py @@ -0,0 +1,59 @@ +from database_engine.database import DBOperation +from database_engine.database_util import getattr_either + +TABLE_NAME = "support_electric_equipment_space_type_name_tags" + +RECORD_HELP = """ +Must provide a dict that contains following key value pairs: +support_electric_equipment_space_type_name_tags: TEXT +""" + +CREATE_support_electric_equipment_space_type_name_tags = f""" +CREATE TABLE IF NOT EXISTS {TABLE_NAME} +( +support_electric_equipment_space_type_name_tags TEXT UNIQUE NOT NULL PRIMARY KEY +); +""" + +INSERT_SPACE_TAG = f""" + INSERT INTO {TABLE_NAME} + (support_electric_equipment_space_type_name_tags) + VALUES (?); +""" + + +RECORD_TEMPLATE = { + "support_electric_equipment_space_type_name_tags": "", +} + + +class PlugLoadSpaceTagTable(DBOperation): + def __init__(self): + super(PlugLoadSpaceTagTable, self).__init__( + table_name=TABLE_NAME, + record_template=RECORD_TEMPLATE, + initial_data_directory=f"initial_data/{TABLE_NAME}", + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def _preprocess_record(self, record): + """ + + :param record: dict + :return: + """ + return ( + getattr_either("support_electric_equipment_space_type_name_tags", record), + ) + + def _get_create_table_query(self): + return CREATE_support_electric_equipment_space_type_name_tags + + def _get_insert_record_query(self): + return INSERT_SPACE_TAG diff --git a/data/openstudio_standards_data/database_tables/support_lighting_space_type_name_tags.py b/data/openstudio_standards_data/database_tables/support_lighting_space_type_name_tags.py new file mode 100644 index 0000000000..0080e390be --- /dev/null +++ b/data/openstudio_standards_data/database_tables/support_lighting_space_type_name_tags.py @@ -0,0 +1,57 @@ +from database_engine.database import DBOperation +from database_engine.database_util import getattr_either + +TABLE_NAME = "support_lighting_space_type_name_tags" + +RECORD_HELP = """ +Must provide a dict that contains following key value pairs: +lighting_space_type_name: TEXT +""" + +CREATE_LIGHTING_SPACE_TAG = f""" +CREATE TABLE IF NOT EXISTS {TABLE_NAME} +( +lighting_space_type_name TEXT UNIQUE NOT NULL PRIMARY KEY +); +""" + +INSERT_SPACE_TAG = f""" + INSERT INTO {TABLE_NAME} + (lighting_space_type_name) + VALUES (?); +""" + + +RECORD_TEMPLATE = { + "lighting_space_type_name": "", +} + + +class LightingSpaceTagTable(DBOperation): + def __init__(self): + super(LightingSpaceTagTable, self).__init__( + table_name=TABLE_NAME, + record_template=RECORD_TEMPLATE, + initial_data_directory=f"initial_data/{TABLE_NAME}", + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def _preprocess_record(self, record): + """ + + :param record: dict + :return: + """ + return (getattr_either("lighting_space_type_name", record),) + + def _get_create_table_query(self): + return CREATE_LIGHTING_SPACE_TAG + + def _get_insert_record_query(self): + return INSERT_SPACE_TAG diff --git a/data/openstudio_standards_data/database_tables/support_materials.py b/data/openstudio_standards_data/database_tables/support_materials.py new file mode 100644 index 0000000000..ac4638b078 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/support_materials.py @@ -0,0 +1,251 @@ +from database_engine.database import DBOperation +from database_engine.database_util import getattr_either, is_float + +TABLE_NAME = "support_materials" + +RECORD_HELP = """ +Must provide a dict that contains following key value pairs: +name: TEXT +material_type: TEXT +roughness: NUMERIC +thickness: NUMERIC +conductivity: NUMERIC +resistance: NUMERIC +density: NUMERIC +specific_heat: NUMERIC +thermal_absorptance: NUMERIC +solar_absorptance: NUMERIC +visible_absorptance: NUMERIC +u_factor: NUMERIC +solar_heat_gain_coefficient: NUMERIC +visible_transmittance: NUMERIC +gas_type: TEXT +optical_data_type: TEXT +solar_transmittance_at_normal_incidence: NUMERIC +front_side_solar_reflectance_at_normal_incidence: NUMERIC +back_side_solar_reflectance_at_normal_incidence: NUMERIC +visible_transmittance_at_normal_incidence: NUMERIC +front_side_visible_reflectance_at_normal_incidence: NUMERIC +back_side_visible_reflectance_at_normal_incidence: NUMERIC +infrared_transmittance_at_normal_incidence: NUMERIC +front_side_infrared_hemispherical_emissivity: NUMERIC +back_side_infrared_hemispherical_emissivity: NUMERIC +dirt_correction_factor_for_solar_and_visible_transmittance: NUMERIC +solar_diffusing: TEXT +frame_width: NUMERIC +annotation: TEXT +""" + +CREATE_MATERIALS_TABLE = f""" +CREATE TABLE IF NOT EXISTS {TABLE_NAME} +(name TEXT UNIQUE NOT NULL PRIMARY KEY, +material_type TEXT, +roughness NUMERIC, +thickness NUMERIC, +conductivity NUMERIC, +resistance NUMERIC, +density NUMERIC, +specific_heat NUMERIC, +thermal_absorptance NUMERIC, +solar_absorptance NUMERIC, +visible_absorptance NUMERIC, +gas_type TEXT, +u_factor NUMERIC, +solar_heat_gain_coefficient NUMERIC, +visible_transmittance NUMERIC, +optical_data_type TEXT, +solar_transmittance_at_normal_incidence NUMERIC, +front_side_solar_reflectance_at_normal_incidence NUMERIC, +back_side_solar_reflectance_at_normal_incidence NUMERIC, +visible_transmittance_at_normal_incidence NUMERIC, +front_side_visible_reflectance_at_normal_incidence NUMERIC, +back_side_visible_reflectance_at_normal_incidence NUMERIC, +infrared_transmittance_at_normal_incidence NUMERIC, +front_side_infrared_hemispherical_emissivity NUMERIC, +back_side_infrared_hemispherical_emissivity NUMERIC, +dirt_correction_factor_for_solar_and_visible_transmittance NUMERIC, +solar_diffusing TEXT, +frame_width NUMERIC, +annotation TEXT +); +""" + +INSERT_MATERIAL = f""" + INSERT INTO {TABLE_NAME} + (name, +material_type, +roughness, +thickness, +conductivity, +resistance, +density, +specific_heat, +thermal_absorptance, +solar_absorptance, +visible_absorptance, +gas_type, +u_factor, +solar_heat_gain_coefficient, +visible_transmittance, +optical_data_type, +solar_transmittance_at_normal_incidence, +front_side_solar_reflectance_at_normal_incidence, +back_side_solar_reflectance_at_normal_incidence, +visible_transmittance_at_normal_incidence, +front_side_visible_reflectance_at_normal_incidence, +back_side_visible_reflectance_at_normal_incidence, +infrared_transmittance_at_normal_incidence, +front_side_infrared_hemispherical_emissivity, +back_side_infrared_hemispherical_emissivity, +dirt_correction_factor_for_solar_and_visible_transmittance, +solar_diffusing, +frame_width, +annotation) + VALUES (?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?); +""" + + +RECORD_TEMPLATE = { + "name": "", + "material_type": "", + "roughness": "", + "thickness": 0.0, + "conductivity": 0.0, + "resistance": 0.0, + "density": 0.0, + "specific_heat": 0.0, + "thermal_absorptance": 0.0, + "solar_absorptance": 0.0, + "visible_absorptance": 0.0, + "gas_type": "", + "u_factor": 0.0, + "solar_heat_gain_coefficient": 0.0, + "visible_transmittance": 0.0, + "optical_data_type": "", + "solar_transmittance_at_normal_incidence": 0.0, + "front_side_solar_reflectance_at_normal_incidence": 0.0, + "back_side_solar_reflectance_at_normal_incidence": 0.0, + "visible_transmittance_at_normal_incidence": 0.0, + "front_side_visible_reflectance_at_normal_incidence": 0.0, + "back_side_visible_reflectance_at_normal_incidence": 0.0, + "infrared_transmittance_at_normal_incidence": 0.0, + "front_side_infrared_hemispherical_emissivity": 0.0, + "back_side_infrared_hemispherical_emissivity": 0.0, + "dirt_correction_factor_for_solar_and_visible_transmittance": 0.0, + "solar_diffusing": "", + "frame_width": 0.0, + "annotation": "", +} + + +class SupportMaterialTable(DBOperation): + def __init__(self): + super(SupportMaterialTable, self).__init__( + table_name=TABLE_NAME, + record_template=RECORD_TEMPLATE, + initial_data_directory=f"initial_data/{TABLE_NAME}", + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def validate_record_datatype(self, record): + str_expected = [ + "name", + "material_type", + "roughness", + "annotation", + "gas_type", + "optical_data_type", + "solar_diffusing", + ] + + for f in str_expected: + if record.get(f): + assert isinstance( + record[f], str + ), f"{f} requires to be a string, instead got {record[f]}" + + float_expected = [ + "thickness", + "conductivity", + "resistance", + "density", + "specific_heat", + "thermal_absorptance", + "solar_absorptance", + "visible_absorptance", + "u_factor", + "solar_heat_gain_coefficient", + "visible_transmittance", + "frame_width", + "solar_transmittance_at_normal_incidence", + "front_side_solar_reflectance_at_normal_incidence", + "back_side_solar_reflectance_at_normal_incidence", + "visible_transmittance_at_normal_incidence", + "front_side_visible_reflectance_at_normal_incidence", + "back_side_visible_reflectance_at_normal_incidence", + "infrared_transmittance_at_normal_incidence", + "front_side_infrared_hemispherical_emissivity", + "back_side_infrared_hemispherical_emissivity", + "dirt_correction_factor_for_solar_and_visible_transmittance", + ] + + for f in float_expected: + if record.get(f): + assert is_float( + record.get(f) + ), f"{f} requires to be numeric data type, instead got {record[f]}" + + def _preprocess_record(self, record): + """ + + :param record: dict + :return: + """ + + return ( + getattr_either("name", record), + getattr_either("material_type", record), + getattr_either("roughness", record), + getattr_either("thickness", record), + getattr_either("conductivity", record), + getattr_either("resistance", record), + getattr_either("density", record), + getattr_either("specific_heat", record), + getattr_either("thermal_absorptance", record), + getattr_either("solar_absorptance", record), + getattr_either("visible_absorptance", record), + getattr_either("gas_type", record), + getattr_either("u_factor", record), + getattr_either("solar_heat_gain_coefficient", record), + getattr_either("visible_transmittance", record), + getattr_either("optical_data_type", record), + getattr_either("solar_transmittance_at_normal_incidence", record), + getattr_either("front_side_solar_reflectance_at_normal_incidence", record), + getattr_either("back_side_solar_reflectance_at_normal_incidence", record), + getattr_either("visible_transmittance_at_normal_incidence", record), + getattr_either( + "front_side_visible_reflectance_at_normal_incidence", record + ), + getattr_either("back_side_visible_reflectance_at_normal_incidence", record), + getattr_either("infrared_transmittance_at_normal_incidence", record), + getattr_either("front_side_infrared_hemispherical_emissivity", record), + getattr_either("back_side_infrared_hemispherical_emissivity", record), + getattr_either( + "dirt_correction_factor_for_solar_and_visible_transmittance", record + ), + getattr_either("solar_diffusing", record), + getattr_either("frame_width", record), + getattr_either("annotation", record), + ) + + def _get_create_table_query(self): + return CREATE_MATERIALS_TABLE + + def _get_insert_record_query(self): + return INSERT_MATERIAL diff --git a/data/openstudio_standards_data/database_tables/support_performance_curves.py b/data/openstudio_standards_data/database_tables/support_performance_curves.py new file mode 100644 index 0000000000..943a636d87 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/support_performance_curves.py @@ -0,0 +1,212 @@ +from database_engine.database import DBOperation +from database_engine.database_util import is_float, getattr_either + +TABLE_NAME = "support_performance_curves" + +RECORD_HELP = """ +Must provide a dict that contains following key value pairs: +ventilation_space_type_name: TEXT +name: TEXT +category: TEXT +form: TEXT +dependent_variable: TEXT +independent_variable_1: TEXT +independent_variable_2: TEXT +coeff_1: NUMERIC +coeff_2: NUMERIC +coeff_3: NUMERIC +coeff_4: NUMERIC +coeff_5: NUMERIC +coeff_6: NUMERIC +coeff_7: NUMERIC +coeff_8: NUMERIC +coeff_9: NUMERIC +coeff_10: NUMERIC +minimum_independent_variable_1: NUMERIC +maximum_independent_variable_1: NUMERIC +minimum_independent_variable_2: NUMERIC +maximum_independent_variable_2: NUMERIC +minimum_dependent_variable_output: NUMERIC +maximum_dependent_variable_output: NUMERIC +annotation: TEXT +""" + +CREATE_PERFORMANCE_CURVES_TABLE = f""" +CREATE TABLE IF NOT EXISTS {TABLE_NAME} +( +id INTEGER PRIMARY KEY, +name TEXT NOT NULL, +category TEXT, +form TEXT NOT NULL, +dependent_variable TEXT, +independent_variable_1 TEXT, +independent_variable_2 TEXT, +coeff_1 NUMERIC, +coeff_2 NUMERIC, +coeff_3 NUMERIC, +coeff_4 NUMERIC, +coeff_5 NUMERIC, +coeff_6 NUMERIC, +coeff_7 NUMERIC, +coeff_8 NUMERIC, +coeff_9 NUMERIC, +coeff_10 NUMERIC, +minimum_independent_variable_1 NUMERIC, +maximum_independent_variable_1 NUMERIC, +minimum_independent_variable_2 NUMERIC, +maximum_independent_variable_2 NUMERIC, +minimum_dependent_variable_output NUMERIC, +maximum_dependent_variable_output NUMERIC, +annotation TEXT +); +""" + +INSERT_PERFORMANCE_CURVE = f""" + INSERT INTO {TABLE_NAME} + ( +name, +category, +form, +dependent_variable, +independent_variable_1, +independent_variable_2, +coeff_1, +coeff_2, +coeff_3, +coeff_4, +coeff_5, +coeff_6, +coeff_7, +coeff_8, +coeff_9, +coeff_10, +minimum_independent_variable_1, +maximum_independent_variable_1, +minimum_independent_variable_2, +maximum_independent_variable_2, +minimum_dependent_variable_output, +maximum_dependent_variable_output, +annotation) + VALUES (?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?); +""" + + +RECORD_TEMPLATE = { + "name": "", + "category": "", + "form": "", + "dependent_variable": "", + "independent_variable_1": "", + "independent_variable_2": "", + "coeff_1": 0.0, + "coeff_2": 0.0, + "coeff_3": 0.0, + "coeff_4": 0.0, + "coeff_5": 0.0, + "coeff_6": 0.0, + "coeff_7": 0.0, + "coeff_8": 0.0, + "coeff_9": 0.0, + "coeff_10": 0.0, + "minimum_independent_variable_1": 0.0, + "maximum_independent_variable_1": 0.0, + "minimum_independent_variable_2": 0.0, + "maximum_independent_variable_2": 0.0, + "minimum_dependent_variable_output": 0.0, + "maximum_dependent_variable_output": 0.0, + "annotation": "", +} + + +class VentSpaceTagTable(DBOperation): + def __init__(self): + super(VentSpaceTagTable, self).__init__( + table_name=TABLE_NAME, + record_template=RECORD_TEMPLATE, + initial_data_directory=f"initial_data/{TABLE_NAME}", + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def validate_record_datatype(self, record): + str_expected = [ + "name", + "category", + "form", + "dependent_variable", + "independent_variable_1", + "independent_variable_2", + ] + + for f in str_expected: + if record.get(f): + assert isinstance( + record[f], str + ), f"{f} requires to be a string, instead got {record[f]}" + + float_expected = [ + "minimum_independent_variable_1", + "minimum_independent_variable_2", + "maximum_independent_variable_1", + "maximum_independent_variable_2", + "minimum_dependent_variable_output", + "maximum_dependent_variable_output", + ] + + for f in float_expected: + if record.get(f): + assert is_float( + record.get(f) + ), f"{f} requires to be numeric data type, instead got {record[f]}" + + for i in range(10): + if record.get(f"coeff_{i+1}"): + coeff = f"coeff_{i+1}" + record_id = record[f"{coeff}"] + assert is_float( + record.get(coeff) + ), f"{coeff} requires to be numeric data type, instead got {record_id}" + + def _preprocess_record(self, record): + """ + + :param record: dict + :return: + """ + + return ( + getattr_either("name", record), + getattr_either("category", record), + getattr_either("form", record), + getattr_either("dependent_variable", record), + getattr_either("independent_variable_1", record), + getattr_either("independent_variable_2", record), + getattr_either("coeff_1", record), + getattr_either("coeff_2", record), + getattr_either("coeff_3", record), + getattr_either("coeff_4", record), + getattr_either("coeff_5", record), + getattr_either("coeff_6", record), + getattr_either("coeff_7", record), + getattr_either("coeff_8", record), + getattr_either("coeff_9", record), + getattr_either("coeff_10", record), + getattr_either("minimum_independent_variable_1", record), + getattr_either("maximum_independent_variable_1", record), + getattr_either("minimum_independent_variable_2", record), + getattr_either("maximum_independent_variable_2", record), + getattr_either("minimum_dependent_variable_output", record), + getattr_either("maximum_dependent_variable_output", record), + getattr_either("annotation", record), + ) + + def _get_create_table_query(self): + return CREATE_PERFORMANCE_CURVES_TABLE + + def _get_insert_record_query(self): + return INSERT_PERFORMANCE_CURVE diff --git a/data/openstudio_standards_data/database_tables/support_standard_templates.py b/data/openstudio_standards_data/database_tables/support_standard_templates.py new file mode 100644 index 0000000000..62cccfdfcd --- /dev/null +++ b/data/openstudio_standards_data/database_tables/support_standard_templates.py @@ -0,0 +1,74 @@ +import sqlite3 + +from database_engine.database import DBOperation +from database_engine.database_util import getattr_either + +TABLE_NAME = "support_standard_templates" + +RECORD_HELP = """ +Must provide a tuple that contains: +template,TEXT +lighting_standard,TEXT +ventilation_standard, TEXT +""" + +CREATE_support_standard_templates = """ +CREATE TABLE IF NOT EXISTS support_standard_templates +(id INTEGER PRIMARY KEY, +template TEXT NOT NULL UNIQUE, +lighting_standard TEXT, +lighting_standard_table TEXT, +ventilation_standard TEXT, +ventilation_standard_table TEXT); +""" + +INSERT_A_TEMPLATE_RECORD = """ + INSERT INTO support_standard_templates (template, +lighting_standard, lighting_standard_table, ventilation_standard, ventilation_standard_table) +VALUES (?, ?, ?, ? , ?); +""" + +RECORD_TEMPLATE = { + "template": "", + "lighting_standard": "", + "lighting_standard_table": "", + "ventilation_standard": "", + "ventilation_standard_table": "", +} + + +class StandardTemplateTable(DBOperation): + def __init__(self): + super(StandardTemplateTable, self).__init__( + table_name=TABLE_NAME, + record_template=RECORD_TEMPLATE, + initial_data_directory=f"initial_data/{TABLE_NAME}", + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def _preprocess_record(self, record): + """ + + :param record: dict + :return: + """ + + return ( + getattr_either("template", record), + getattr_either("lighting_standard", record), + getattr_either("lighting_standard_table", record), + getattr_either("ventilation_standard", record), + getattr_either("ventilation_standard_table", record), + ) + + def _get_create_table_query(self): + return CREATE_support_standard_templates + + def _get_insert_record_query(self): + return INSERT_A_TEMPLATE_RECORD diff --git a/data/openstudio_standards_data/database_tables/support_ventilation_space_type_name_tags.py b/data/openstudio_standards_data/database_tables/support_ventilation_space_type_name_tags.py new file mode 100644 index 0000000000..7bdd2d78f8 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/support_ventilation_space_type_name_tags.py @@ -0,0 +1,58 @@ +from database_engine.database import DBOperation +from database_engine.database_util import getattr_either + +TABLE_NAME = "support_ventilation_space_type_name_tags" + +RECORD_HELP = """ +Must provide a dict that contains following key value pairs: +ventilation_space_type_name: TEXT +""" + +CREATE_ventilation_space_type_name = f""" +CREATE TABLE IF NOT EXISTS {TABLE_NAME} +( +ventilation_space_type_name TEXT UNIQUE NOT NULL PRIMARY KEY +); +""" + +INSERT_SPACE_TAG = f""" + INSERT INTO {TABLE_NAME} + (ventilation_space_type_name) + VALUES (?); +""" + + +RECORD_TEMPLATE = { + "ventilation_space_type_name": "", +} + + +class VentSpaceTagTable(DBOperation): + def __init__(self): + super(VentSpaceTagTable, self).__init__( + table_name=TABLE_NAME, + record_template=RECORD_TEMPLATE, + initial_data_directory=f"initial_data/{TABLE_NAME}", + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def _preprocess_record(self, record): + """ + + :param record: dict + :return: + """ + + return (getattr_either("ventilation_space_type_name", record),) + + def _get_create_table_query(self): + return CREATE_ventilation_space_type_name + + def _get_insert_record_query(self): + return INSERT_SPACE_TAG diff --git a/data/openstudio_standards_data/database_tables/system_requirement_economizer.py b/data/openstudio_standards_data/database_tables/system_requirement_economizer.py new file mode 100644 index 0000000000..d94751a7a0 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/system_requirement_economizer.py @@ -0,0 +1,109 @@ +from database_engine.database import DBOperation +from database_engine.database_util import is_float, getattr_either + +RECORD_HELP = """ +Must provide a tuple that contains: +template: TEXT +climate_zone: TEXT +data_center: TEXT +capacity_limit: NUMERIC +fixed_dry_bulb_high_limit_shutoff_temp: NUMERIC +annotation: TEXT (optional) +""" + +CREATE_SYSTEM_REQUIREMENT_ECONOMIZER_TABLE = """ +CREATE TABLE IF NOT EXISTS %s +(id INTEGER PRIMARY KEY, +template TEXT NOT NULL, +climate_zone TEXT NOT NULL, +data_center TEXT, +capacity_limit NUMERIC, +fixed_dry_bulb_high_limit_shutoff_temp NUMERIC, +annotation TEXT); +""" + +INSERT_A_SYSTEM_REQUIREMENT_ECONOMIZER = """ + INSERT INTO %s ( +template, +climate_zone, +data_center, +capacity_limit, +fixed_dry_bulb_high_limit_shutoff_temp, +annotation +) +VALUES (?, ?, ?, ?, ?, ?); +""" + +RECORD_TEMPLATE = { + "template": "", + "climate_zone": "", + "data_center": "", + "capacity_limit": 0.0, + "fixed_dry_bulb_high_limit_shutoff_temp": 0.0, + "annotation": "", +} + + +class SystemRequirementEconomizer(DBOperation): + def __init__(self, table_name, initial_data_directory): + super(SystemRequirementEconomizer, self).__init__( + table_name=table_name, + record_template=RECORD_TEMPLATE, + initial_data_directory=initial_data_directory, + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def validate_record_datatype(self, record): + str_expected = [ + "template", + "climate_zone", + "data_center", + "subcategory", + "start_date", + "end_date", + ] + + for f in str_expected: + if record.get(f): + assert isinstance( + record[f], str + ), f"{f} requires to be a string, instead got {record[f]}" + + float_expected = [ + "capacity_limit", + "fixed_dry_bulb_high_limit_shutoff_temp", + ] + + for f in float_expected: + if record.get(f): + assert is_float( + record.get(f) + ), f"{f} requires to be numeric data type, instead got {record[f]}" + + def _preprocess_record(self, record): + """ + + :param record: dict + :return: + """ + + return ( + getattr_either("template", record), + getattr_either("climate_zone", record), + getattr_either("data_center", record), + getattr_either("capacity_limit", record), + getattr_either("fixed_dry_bulb_high_limit_shutoff_temp", record), + getattr_either("annotation", record), + ) + + def _get_create_table_query(self): + return CREATE_SYSTEM_REQUIREMENT_ECONOMIZER_TABLE % self.data_table_name + + def _get_insert_record_query(self): + return INSERT_A_SYSTEM_REQUIREMENT_ECONOMIZER % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/system_requirement_economizer_90_1.py b/data/openstudio_standards_data/database_tables/system_requirement_economizer_90_1.py new file mode 100644 index 0000000000..d2b83fd96a --- /dev/null +++ b/data/openstudio_standards_data/database_tables/system_requirement_economizer_90_1.py @@ -0,0 +1,13 @@ +import sqlite3 + +from database_tables.system_requirement_economizer import SystemRequirementEconomizer + +TABLE_NAME = "system_requirement_economizer_90_1" + + +class SystemRequirementEconomizer901Table(SystemRequirementEconomizer): + def __init__(self): + super(SystemRequirementEconomizer901Table, self).__init__( + table_name=TABLE_NAME, + initial_data_directory=f"initial_data/{TABLE_NAME}", + ) diff --git a/data/openstudio_standards_data/database_tables/system_requirement_energy_recovery.py b/data/openstudio_standards_data/database_tables/system_requirement_energy_recovery.py new file mode 100644 index 0000000000..b882c83d34 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/system_requirement_energy_recovery.py @@ -0,0 +1,166 @@ +from database_engine.database import DBOperation +from database_engine.database_util import is_float, getattr_either + +RECORD_HELP = """ +Must provide a tuple that contains: +template: TEXT +climate_zone: TEXT +under_8000_hours: TEXT +nontransient_dwelling: TEXT +percent_oa_0_to_10: NUMERIC +percent_oa_10_to_20: NUMERIC +percent_oa_20_to_30: NUMERIC +percent_oa_30_to_40: NUMERIC +percent_oa_40_to_50: NUMERIC +percent_oa_50_to_60: NUMERIC +percent_oa_60_to_70: NUMERIC +percent_oa_70_to_80: NUMERIC +percent_oa_greater_than_80: NUMERIC +enthalpy_recovery_ratio_design_conditions: TEXT +enthalpy_recovery_ratio: NUMERIC +annotation: TEXT (optional) +""" + +CREATE_SYSTEM_REQUIREMENT_ENERGY_RECOVERY_TABLE = """ +CREATE TABLE IF NOT EXISTS %s +(id INTEGER PRIMARY KEY, +template TEXT NOT NULL, +climate_zone TEXT NOT NULL, +under_8000_hours TEXT, +nontransient_dwelling TEXT, +percent_oa_0_to_10 NUMERIC, +percent_oa_10_to_20 NUMERIC, +percent_oa_20_to_30 NUMERIC, +percent_oa_30_to_40 NUMERIC, +percent_oa_40_to_50 NUMERIC, +percent_oa_50_to_60 NUMERIC, +percent_oa_60_to_70 NUMERIC, +percent_oa_70_to_80 NUMERIC, +percent_oa_greater_than_80 NUMERIC, +enthalpy_recovery_ratio_design_conditions TEXT, +enthalpy_recovery_ratio NUMERIC, +annotation TEXT); +""" + +INSERT_A_SYSTEM_REQUIREMENT_ENERGY_RECOVERY_RECORD = """ + INSERT INTO %s ( +template, +climate_zone, +under_8000_hours, +nontransient_dwelling, +percent_oa_0_to_10, +percent_oa_10_to_20, +percent_oa_20_to_30, +percent_oa_30_to_40, +percent_oa_40_to_50, +percent_oa_50_to_60, +percent_oa_60_to_70, +percent_oa_70_to_80, +percent_oa_greater_than_80, +enthalpy_recovery_ratio_design_conditions, +enthalpy_recovery_ratio, +annotation +) +VALUES (?, ?, ?, ? , ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?); +""" + +RECORD_TEMPLATE = { + "template": "", + "climate_zone": "", + "under_8000_hours": "", + "nontransient_dwelling": "", + "percent_oa_0_to_10": 0.0, + "percent_oa_10_to_20": 0.0, + "percent_oa_20_to_30": 0.0, + "percent_oa_30_to_40": 0.0, + "percent_oa_40_to_50": 0.0, + "percent_oa_50_to_60": 0.0, + "percent_oa_60_to_70": 0.0, + "percent_oa_70_to_80": 0.0, + "percent_oa_greater_than_80": 0.0, + "enthalpy_recovery_ratio_design_conditions": "", + "enthalpy_recovery_ratio": 0.0, + "annotation": "", +} + + +class SystemRequirementEnergyRecovery(DBOperation): + def __init__(self, table_name, initial_data_directory): + super(SystemRequirementEnergyRecovery, self).__init__( + table_name=table_name, + record_template=RECORD_TEMPLATE, + initial_data_directory=initial_data_directory, + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def validate_record_datatype(self, record): + str_expected = [ + "template", + "climate_zone", + "under_8000_hours", + "nontransient_dwelling", + "enthalpy_recovery_ratio_design_conditions", + ] + + for f in str_expected: + if record.get(f): + assert isinstance( + record[f], str + ), f"{f} requires to be a string, instead got {record[f]}" + + float_expected = [ + "percent_oa_0_to_10", + "percent_oa_10_to_20", + "percent_oa_20_to_30", + "percent_oa_30_to_40", + "percent_oa_40_to_50", + "percent_oa_50_to_60", + "percent_oa_60_to_70", + "percent_oa_70_to_80", + "percent_oa_greater_than_80", + "enthalpy_recovery_ratio", + ] + + for f in float_expected: + if record.get(f): + assert is_float( + record.get(f) + ), f"{f} requires to be numeric data type, instead got {record[f]}" + + def _preprocess_record(self, record): + """ + + :param record: dict + :return: + """ + + return ( + getattr_either("template", record), + getattr_either("climate_zone", record), + getattr_either("under_8000_hours", record), + getattr_either("nontransient_dwelling", record), + getattr_either("percent_oa_0_to_10", record), + getattr_either("percent_oa_10_to_20", record), + getattr_either("percent_oa_20_to_30", record), + getattr_either("percent_oa_30_to_40", record), + getattr_either("percent_oa_40_to_50", record), + getattr_either("percent_oa_50_to_60", record), + getattr_either("percent_oa_60_to_70", record), + getattr_either("percent_oa_70_to_80", record), + getattr_either("percent_oa_greater_than_80", record), + getattr_either("enthalpy_recovery_ratio_design_conditions", record), + getattr_either("enthalpy_recovery_ratio", record), + getattr_either("annotation", record), + ) + + def _get_create_table_query(self): + return CREATE_SYSTEM_REQUIREMENT_ENERGY_RECOVERY_TABLE % self.data_table_name + + def _get_insert_record_query(self): + return INSERT_A_SYSTEM_REQUIREMENT_ENERGY_RECOVERY_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/system_requirement_energy_recovery_90_1.py b/data/openstudio_standards_data/database_tables/system_requirement_energy_recovery_90_1.py new file mode 100644 index 0000000000..c3af6f5ca4 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/system_requirement_energy_recovery_90_1.py @@ -0,0 +1,15 @@ +import sqlite3 + +from database_tables.system_requirement_energy_recovery import ( + SystemRequirementEnergyRecovery, +) + +TABLE_NAME = "system_requirement_energy_recovery_90_1" + + +class SystemRequirementEnergyRecovery901Table(SystemRequirementEnergyRecovery): + def __init__(self): + super(SystemRequirementEnergyRecovery901Table, self).__init__( + table_name=TABLE_NAME, + initial_data_directory=f"initial_data/{TABLE_NAME}", + ) diff --git a/data/openstudio_standards_data/initial_data/envelope_requirement.csv b/data/openstudio_standards_data/initial_data/envelope_requirement.csv new file mode 100644 index 0000000000..19467ee5b2 --- /dev/null +++ b/data/openstudio_standards_data/initial_data/envelope_requirement.csv @@ -0,0 +1,4534 @@ +template,climate_zone_set,intended_surface_type,standards_construction_type,building_category,construction,orientation,minimum_percent_of_surface,maximum_percent_of_surface,assembly_maximum_u_value,u_value_includes_interior_film_coefficient,u_value_includes_exterior_film_coefficient,asssembly_maximum_f_factor,assembly_maximum_c_factor,assembly_maximum_solar_heat_gain_coefficient,assembly_minimum_vt_shgc,annotation +90.1-2004,ClimateZone 1,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 1,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,1.282,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.614,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,1.28,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2004,ClimateZone 1,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,1.18,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 2,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.167,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2004,ClimateZone 2,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.184,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 2,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 2,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 2,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 2,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 2,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 2,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 2,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 2,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 2,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 2,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 2,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 2,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.34 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 2,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 2,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 2,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 3A,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 3B,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 3C,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 3,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2004,ClimateZone 3A,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2004,ClimateZone 3B,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2004,ClimateZone 3C,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2004,ClimateZone 3,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2004,ClimateZone 3A,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2004,ClimateZone 3B,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2004,ClimateZone 3C,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2004,ClimateZone 3,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 3A,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 3B,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 3C,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 3A,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.184,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 3A,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 3A,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 3A,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 3A,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 3A,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 3A,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 3A,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 3A,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 3A,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.39 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.36 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.34 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.34,, +90.1-2004,ClimateZone 3A,Skylight,Plastic with Curb,Nonresidential,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.27,, +90.1-2004,ClimateZone 3A,Skylight,Plastic with Curb,Residential,U 1.30 SHGC 0.27 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.27,, +90.1-2004,ClimateZone 3A,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.39 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,Skylight,Without Curb,Residential,U 0.69 SHGC 0.36 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 3A,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3B,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.184,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 3B,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 3B,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 3B,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 3B,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 3B,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 3B,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 3B,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 3B,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 3B,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.39 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3B,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.36 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,Skylight,Plastic with Curb,Nonresidential,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3B,Skylight,Plastic with Curb,Residential,U 1.30 SHGC 0.27 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 3B,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3B,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.39 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,Skylight,Without Curb,Residential,U 0.69 SHGC 0.36 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.65,, +90.1-2004,ClimateZone 3C,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.184,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.61,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.61,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.61,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Residential,U 0.72 SHGC 0.25 Simple Glazing Window,,40.001,100,0.72,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.72 SHGC 0.25 Simple Glazing Window,,40.001,100,0.72,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Residential,U 0.72 SHGC 0.25 Simple Glazing Window,,40.001,100,0.72,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.61,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Residential,U 0.72 SHGC 0.25 Simple Glazing Window,,40.001,100,0.72,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 3C,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 3C,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 3C,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 3C,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 3C,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 3C,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 3C,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 3C,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 3C,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.61 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.27,, +90.1-2004,ClimateZone 3C,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.39 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.27,, +90.1-2004,ClimateZone 3C,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.39 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.65 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.65 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3C,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 3C,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.61 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3C,Skylight,Without Curb,Residential,U 1.36 SHGC 0.39 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 4,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2004,ClimateZone 4,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.134,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 4,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.95,,,, +90.1-2004,ClimateZone 4,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 4,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.84,,,, +90.1-2004,ClimateZone 4,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 4,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 4,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 4,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 4,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 4,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 4,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.36 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 4,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 4,Skylight,Plastic with Curb,Nonresidential,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,Skylight,Plastic with Curb,Residential,U 1.30 SHGC 0.62 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.65,, +90.1-2004,ClimateZone 4,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.27,, +90.1-2004,ClimateZone 4,Skylight,Without Curb,Residential,U 0.58 SHGC 0.36 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,0.27,, +90.1-2004,ClimateZone 4,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 5,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2004,ClimateZone 5,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 5,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.84,,,, +90.1-2004,ClimateZone 5,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 5,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.84,,,, +90.1-2004,ClimateZone 5,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 5,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 5,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 5,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 5,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 5,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 5,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.36 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 5,Skylight,Plastic with Curb,Nonresidential,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 5,Skylight,Plastic with Curb,Residential,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.61,, +90.1-2004,ClimateZone 5,Skylight,Without Curb,Residential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 6,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.0066,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 6,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2004,ClimateZone 6,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 6,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.84,,,, +90.1-2004,ClimateZone 6,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 6,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.78,,,, +90.1-2004,ClimateZone 6,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 6,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 6,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 6,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 6,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2004,ClimateZone 6,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 6,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.45 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.65 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.65,, +90.1-2004,ClimateZone 6,Skylight,Plastic with Curb,Nonresidential,U 0.87 SHGC 0.71 Simple Glazing Skylight,,0,2,0.87,TRUE,TRUE,,,0.65,, +90.1-2004,ClimateZone 6,Skylight,Plastic with Curb,Residential,U 0.74 SHGC 0.65 Simple Glazing Skylight,,0,2,0.74,TRUE,TRUE,,,0.34,, +90.1-2004,ClimateZone 6,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,Skylight,Without Curb,Residential,U 0.58 SHGC 0.61 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,0.61,, +90.1-2004,ClimateZone 6,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 7,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 7,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2004,ClimateZone 7,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 7,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.84,,,, +90.1-2004,ClimateZone 7,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, +90.1-2004,ClimateZone 7,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.78,,,, +90.1-2004,ClimateZone 7,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 7,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 7,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 7,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2004,ClimateZone 7,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2004,ClimateZone 7,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 7,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.68 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 7,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.64 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,Skylight,Plastic with Curb,Nonresidential,U 0.87 SHGC 0.77 Simple Glazing Skylight,,0,2,0.87,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,Skylight,Plastic with Curb,Residential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 7,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 7,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.68 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,Skylight,Without Curb,Residential,U 0.69 SHGC 0.64 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.65,, +90.1-2004,ClimateZone 8,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 8,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.072,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2004,ClimateZone 8,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.055,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, +90.1-2004,ClimateZone 8,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.78,,,, +90.1-2004,ClimateZone 8,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2004,ClimateZone 8,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.78,,,, +90.1-2004,ClimateZone 8,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 8,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.95,,,, +90.1-2004,ClimateZone 8,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 8,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2004,ClimateZone 8,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2004,ClimateZone 8,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 8,Skylight,Glass with Curb,Nonresidential,U 0.98 SHGC 0.62 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.62,, +90.1-2004,ClimateZone 8,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.27 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.27,, +90.1-2004,ClimateZone 8,Skylight,Glass with Curb,Semiheated,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,Skylight,Plastic with Curb,Nonresidential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,Skylight,Plastic with Curb,Residential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 8,Skylight,Plastic with Curb,Semiheated,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 8,Skylight,Without Curb,Nonresidential,U 0.58 SHGC 0.19 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 8,Skylight,Without Curb,Residential,U 0.58 SHGC 0.45 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,Skylight,Without Curb,Semiheated,U 0.81 SHGC 0.65 Simple Glazing Skylight,,0,2,0.81,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 1,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 1,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 1,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 1,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 1,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 1,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 1,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 1,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 1,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 1,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.36 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 1,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 1,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.16 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.16,, +90.1-2004,ClimateZone 1,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.34 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.34,, +90.1-2004,ClimateZone 1,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.27,, +90.1-2004,ClimateZone 1,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.27,, +90.1-2004,ClimateZone 1,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 1,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.065,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.063,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.65,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,1.28,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2007,ClimateZone 1,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 2,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.167,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2007,ClimateZone 2,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.184,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2007,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.7 SHGC 0.25 Simple Glazing Window,,,,0.7,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.7 SHGC 0.25 Simple Glazing Window,,,,0.7,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 2,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2007,ClimateZone 2,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 2,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2007,ClimateZone 2,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 2,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2007,ClimateZone 2,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 2,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 2,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 2,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 2,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.49,, +90.1-2007,ClimateZone 2,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.49 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.49,, +90.1-2007,ClimateZone 2,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.39,, +90.1-2007,ClimateZone 2,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.49,, +90.1-2007,ClimateZone 2,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.46,, +90.1-2007,ClimateZone 2,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.36,, +90.1-2007,ClimateZone 3,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 3,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2007,ClimateZone 3,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.184,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2007,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 3,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 3,ExteriorWindow,Metal framing (all other),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.9 SHGC 0.25 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 3,GlassDoor,Metal framing (entrance door),Residential,U 0.9 SHGC 0.25 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 3,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 3,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2007,ClimateZone 3,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 3,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.09,,,, +90.1-2007,ClimateZone 3,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 3,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2007,ClimateZone 3,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 3,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 3,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 3,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 3,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.39 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.36 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.71 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.71,, +90.1-2007,ClimateZone 3,Skylight,Plastic with Curb,Nonresidential,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.65,, +90.1-2007,ClimateZone 3,Skylight,Plastic with Curb,Residential,U 1.30 SHGC 0.27 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.55,, +90.1-2007,ClimateZone 3,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.39 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,Skylight,Without Curb,Residential,U 0.69 SHGC 0.36 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.49,, +90.1-2007,ClimateZone 3,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.49,, +90.1-2007,ClimateZone 4,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 4,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2007,ClimateZone 4,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.134,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2007,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.4 SHGC 0.4 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.4 SHGC 0.4 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.85 SHGC 0.4 Simple Glazing Window,,,,0.85,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.85 SHGC 0.4 Simple Glazing Window,,,,0.85,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 4,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2007,ClimateZone 4,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, +90.1-2007,ClimateZone 4,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2007,ClimateZone 4,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 4,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2007,ClimateZone 4,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 4,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 4,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2007,ClimateZone 4,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 4,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.39,, +90.1-2007,ClimateZone 4,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.36 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,Skylight,Plastic with Curb,Nonresidential,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.68,, +90.1-2007,ClimateZone 4,Skylight,Plastic with Curb,Residential,U 1.30 SHGC 0.62 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.64,, +90.1-2007,ClimateZone 4,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.64,, +90.1-2007,ClimateZone 4,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,Skylight,Without Curb,Residential,U 0.58 SHGC 0.36 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.77,, +90.1-2007,ClimateZone 5,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 5,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.119,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2007,ClimateZone 5,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2007,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 5,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2007,ClimateZone 5,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, +90.1-2007,ClimateZone 5,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2007,ClimateZone 5,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 5,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2007,ClimateZone 5,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 5,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2007,ClimateZone 5,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2007,ClimateZone 5,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 5,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.77,, +90.1-2007,ClimateZone 5,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.77,, +90.1-2007,ClimateZone 5,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,Skylight,Plastic with Curb,Nonresidential,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,Skylight,Plastic with Curb,Residential,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,0.68,, +90.1-2007,ClimateZone 5,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.64,, +90.1-2007,ClimateZone 5,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.64,, +90.1-2007,ClimateZone 5,Skylight,Without Curb,Residential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 6,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2007,ClimateZone 6,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2007,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.6 SHGC 0.45 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 0.9 SHGC 0.45 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, +90.1-2007,ClimateZone 6,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2007,ClimateZone 6,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2007,ClimateZone 6,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2007,ClimateZone 6,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 6,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2007,ClimateZone 6,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 6,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2007,ClimateZone 6,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2007,ClimateZone 6,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 6,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.45 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,Skylight,Plastic with Curb,Nonresidential,U 0.87 SHGC 0.71 Simple Glazing Skylight,,0,2,0.87,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,Skylight,Plastic with Curb,Residential,U 0.74 SHGC 0.65 Simple Glazing Skylight,,0,2,0.74,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,Skylight,Without Curb,Residential,U 0.58 SHGC 0.45 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 7,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2007,ClimateZone 7,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.042,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2007,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.45,, +90.1-2007,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,, +90.1-2007,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.45,, +90.1-2007,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.6 SHGC 0.45 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.45,, +90.1-2007,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 0.9 SHGC 0.45 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2007,ClimateZone 7,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.843,,,, +90.1-2007,ClimateZone 7,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2007,ClimateZone 7,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2007,ClimateZone 7,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 7,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2007,ClimateZone 7,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 7,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2007,ClimateZone 7,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, +90.1-2007,ClimateZone 7,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 7,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.68 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.64 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,Skylight,Plastic with Curb,Nonresidential,U 0.87 SHGC 0.77 Simple Glazing Skylight,,0,2,0.87,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,Skylight,Plastic with Curb,Residential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.68 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.36,, +90.1-2007,ClimateZone 7,Skylight,Without Curb,Residential,U 0.69 SHGC 0.64 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.19,, +90.1-2007,ClimateZone 7,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.16,, +90.1-2007,ClimateZone 8,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 8,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.072,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2007,ClimateZone 8,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.036,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.052,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.036,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2007,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.45,, +90.1-2007,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,, +90.1-2007,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.45,, +90.1-2007,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.6 SHGC 0.45 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.45,, +90.1-2007,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 0.9 SHGC 0.45 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2007,ClimateZone 8,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2007,ClimateZone 8,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.51,,,, +90.1-2007,ClimateZone 8,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2007,ClimateZone 8,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 8,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2007,ClimateZone 8,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 8,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2007,ClimateZone 8,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.075,,, +90.1-2007,ClimateZone 8,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 8,Skylight,Glass with Curb,Nonresidential,U 0.98 SHGC 0.45 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.45 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,Skylight,Glass with Curb,Semiheated,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.34,, +90.1-2007,ClimateZone 8,Skylight,Plastic with Curb,Nonresidential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,0.27,, +90.1-2007,ClimateZone 8,Skylight,Plastic with Curb,Residential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,0.27,, +90.1-2007,ClimateZone 8,Skylight,Plastic with Curb,Semiheated,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,Skylight,Without Curb,Nonresidential,U 0.58 SHGC 0.45 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,Skylight,Without Curb,Residential,U 0.58 SHGC 0.36 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,0.36,, +90.1-2007,ClimateZone 8,Skylight,Without Curb,Semiheated,U 0.81 SHGC 0.65 Simple Glazing Skylight,,0,2,0.81,TRUE,TRUE,,,0.19,, +90.1-2007,ClimateZone 1,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,1.18,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2007,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 1,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2007,ClimateZone 1,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 1,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2007,ClimateZone 1,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 1,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2007,ClimateZone 1,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 1,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 1,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 1,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 1,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.49 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.49,, +90.1-2007,ClimateZone 1,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.49,, +90.1-2007,ClimateZone 1,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.39 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.39,, +90.1-2007,ClimateZone 1,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.34 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.77,, +90.1-2007,ClimateZone 1,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.77,, +90.1-2007,ClimateZone 1,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.62,, +90.1-2007,ClimateZone 1,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 1,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.065,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.063,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.065,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.167,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2010,ClimateZone 1,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.093,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 2,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2010,ClimateZone 2,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.093,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.093,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2010,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.7 SHGC 0.25 Simple Glazing Window,,,,0.7,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.7 SHGC 0.25 Simple Glazing Window,,,,0.7,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 2,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2010,ClimateZone 2,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2010,ClimateZone 2,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2010,ClimateZone 2,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 2,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 2,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 2,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 2,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 2,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 2,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 2,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.27 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.27,, +90.1-2010,ClimateZone 2,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.27,, +90.1-2010,ClimateZone 2,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.36,, +90.1-2010,ClimateZone 2,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, +90.1-2010,ClimateZone 2,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.19,, +90.1-2010,ClimateZone 2,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 3,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2010,ClimateZone 3,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2010,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 3,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 3,ExteriorWindow,Metal framing (all other),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.9 SHGC 0.25 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 3,GlassDoor,Metal framing (entrance door),Residential,U 0.9 SHGC 0.25 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 3,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,GroundContactFloor,Unheated,Nonresidential,Smallhotel 2010 Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 3,GroundContactFloor,Heated,Nonresidential,Smallhotel 2010 Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2010,ClimateZone 3,GroundContactFloor,Unheated,Residential,Smallhotel 2010 Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 3,GroundContactFloor,Heated,Residential,Smallhotel 2010 Slab Floor,,,,,TRUE,TRUE,0.09,,,, +90.1-2010,ClimateZone 3,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 3,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2010,ClimateZone 3,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 3,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 3,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 3,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 3,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.39 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.39,, +90.1-2010,ClimateZone 3,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.36 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.36,, +90.1-2010,ClimateZone 3,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.19,, +90.1-2010,ClimateZone 3,Skylight,Plastic with Curb,Nonresidential,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,Skylight,Plastic with Curb,Residential,U 1.30 SHGC 0.27 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.65,, +90.1-2010,ClimateZone 3,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.39 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.27,, +90.1-2010,ClimateZone 3,Skylight,Without Curb,Residential,U 0.69 SHGC 0.36 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.27,, +90.1-2010,ClimateZone 3,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 4,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2010,ClimateZone 4,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2010,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.4 SHGC 0.4 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.4 SHGC 0.4 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.85 SHGC 0.4 Simple Glazing Window,,,,0.85,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.85 SHGC 0.4 Simple Glazing Window,,,,0.85,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 4,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2010,ClimateZone 4,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, +90.1-2010,ClimateZone 4,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2010,ClimateZone 4,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 4,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2010,ClimateZone 4,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 4,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 4,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2010,ClimateZone 4,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 4,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.36 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.39,, +90.1-2010,ClimateZone 4,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.36 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.36,, +90.1-2010,ClimateZone 4,Skylight,Plastic with Curb,Nonresidential,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.19,, +90.1-2010,ClimateZone 4,Skylight,Plastic with Curb,Residential,U 1.30 SHGC 0.62 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.49,, +90.1-2010,ClimateZone 4,Skylight,Without Curb,Residential,U 0.58 SHGC 0.36 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,0.36,, +90.1-2010,ClimateZone 4,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.19,, +90.1-2010,ClimateZone 5,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 5,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.119,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.083,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2010,ClimateZone 5,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.069,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.069,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2010,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 5,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2010,ClimateZone 5,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, +90.1-2010,ClimateZone 5,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2010,ClimateZone 5,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 5,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2010,ClimateZone 5,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 5,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2010,ClimateZone 5,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2010,ClimateZone 5,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 5,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.45 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.65 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.65,, +90.1-2010,ClimateZone 5,Skylight,Plastic with Curb,Nonresidential,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,0.62,, +90.1-2010,ClimateZone 5,Skylight,Plastic with Curb,Residential,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,0.27,, +90.1-2010,ClimateZone 5,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,Skylight,Without Curb,Residential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.49,, +90.1-2010,ClimateZone 5,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.36,, +90.1-2010,ClimateZone 6,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 6,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.072,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2010,ClimateZone 6,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.069,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.069,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2010,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.6 SHGC 0.45 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 0.9 SHGC 0.45 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, +90.1-2010,ClimateZone 6,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2010,ClimateZone 6,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2010,ClimateZone 6,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2010,ClimateZone 6,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 6,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2010,ClimateZone 6,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 6,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2010,ClimateZone 6,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2010,ClimateZone 6,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 6,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.19,, +90.1-2010,ClimateZone 6,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.45 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,Skylight,Plastic with Curb,Nonresidential,U 0.87 SHGC 0.71 Simple Glazing Skylight,,0,2,0.87,TRUE,TRUE,,,0.49,, +90.1-2010,ClimateZone 6,Skylight,Plastic with Curb,Residential,U 0.74 SHGC 0.65 Simple Glazing Skylight,,0,2,0.74,TRUE,TRUE,,,0.49,, +90.1-2010,ClimateZone 6,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.39,, +90.1-2010,ClimateZone 6,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,Skylight,Without Curb,Residential,U 0.58 SHGC 0.45 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.77,, +90.1-2010,ClimateZone 7,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 7,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.072,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2010,ClimateZone 7,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.042,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2010,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.45,, +90.1-2010,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,, +90.1-2010,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.45,, +90.1-2010,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.6 SHGC 0.45 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.45,, +90.1-2010,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 0.9 SHGC 0.45 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2010,ClimateZone 7,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.843,,,, +90.1-2010,ClimateZone 7,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2010,ClimateZone 7,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2010,ClimateZone 7,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 7,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2010,ClimateZone 7,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 7,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2010,ClimateZone 7,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, +90.1-2010,ClimateZone 7,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 7,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.68 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.77,, +90.1-2010,ClimateZone 7,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.64 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.62,, +90.1-2010,ClimateZone 7,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,Skylight,Plastic with Curb,Nonresidential,U 0.87 SHGC 0.77 Simple Glazing Skylight,,0,2,0.87,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,Skylight,Plastic with Curb,Residential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,0.49,, +90.1-2010,ClimateZone 7,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.49,, +90.1-2010,ClimateZone 7,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.68 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.39,, +90.1-2010,ClimateZone 7,Skylight,Without Curb,Residential,U 0.69 SHGC 0.64 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 8,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.035,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.035,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2010,ClimateZone 8,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.036,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.052,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.036,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2010,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.45,, +90.1-2010,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,, +90.1-2010,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.45,, +90.1-2010,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.6 SHGC 0.45 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.45,, +90.1-2010,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 0.9 SHGC 0.45 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2010,ClimateZone 8,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2010,ClimateZone 8,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.51,,,, +90.1-2010,ClimateZone 8,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2010,ClimateZone 8,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 8,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2010,ClimateZone 8,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 8,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2010,ClimateZone 8,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.075,,, +90.1-2010,ClimateZone 8,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 8,Skylight,Glass with Curb,Nonresidential,U 0.98 SHGC 0.49 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.49,, +90.1-2010,ClimateZone 8,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.46 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.46,, +90.1-2010,ClimateZone 8,Skylight,Glass with Curb,Semiheated,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.36,, +90.1-2010,ClimateZone 8,Skylight,Plastic with Curb,Nonresidential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,Skylight,Plastic with Curb,Residential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,Skylight,Plastic with Curb,Semiheated,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,0.71,, +90.1-2010,ClimateZone 8,Skylight,Without Curb,Nonresidential,U 0.58 SHGC 0.65 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,0.65,, +90.1-2010,ClimateZone 8,Skylight,Without Curb,Residential,U 0.58 SHGC 0.55 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,0.55,, +90.1-2010,ClimateZone 8,Skylight,Without Curb,Semiheated,U 0.81 SHGC 0.65 Simple Glazing Skylight,,0,2,0.81,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.093,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2010,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 1,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 1,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2010,ClimateZone 1,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 1,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2010,ClimateZone 1,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 1,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2010,ClimateZone 1,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 1,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 1,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 1,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 1,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.19,, +90.1-2010,ClimateZone 1,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.34 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.36,, +90.1-2010,ClimateZone 1,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, +90.1-2010,ClimateZone 1,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, +90.1-2010,ClimateZone 1,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.39,, +90.1-2013,ClimateZone 1,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 1,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.1156,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2013,ClimateZone 1,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 2,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.096,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2013,ClimateZone 2,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2013,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.4 SHGC 0.25 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.83 SHGC 0.25 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 0.4 SHGC 0.25 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 0.77 SHGC 0.25 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.93 SHGC 0.45 Simple Glazing Window,,,,0.93,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 0.83 SHGC 0.45 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 2,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2013,ClimateZone 2,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 2,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2013,ClimateZone 2,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 2,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2013,ClimateZone 2,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 2,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2013,ClimateZone 2,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2013,ClimateZone 2,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2013,ClimateZone 2,Skylight,Glass with Curb,Nonresidential,U 0.65 SHGC 0.45 Simple Glazing Skylight,,0,2,0.65,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,Skylight,Glass with Curb,Residential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,0,2,0.65,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,Skylight,Glass with Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,0.77,, +90.1-2013,ClimateZone 2,Skylight,Plastic with Curb,Nonresidential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,0,2,0.65,TRUE,TRUE,,,0.77,, +90.1-2013,ClimateZone 2,Skylight,Plastic with Curb,Residential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,0,2,0.65,TRUE,TRUE,,,0.77,, +90.1-2013,ClimateZone 2,Skylight,Plastic with Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,Skylight,Without Curb,Nonresidential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,0,2,0.65,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,Skylight,Without Curb,Residential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,0,2,0.65,TRUE,TRUE,,,0.68,, +90.1-2013,ClimateZone 2,Skylight,Without Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,0.64,, +90.1-2013,ClimateZone 3,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 3,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.119,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.096,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2013,ClimateZone 3,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.077,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.072,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2013,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.25 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 3,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.25 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.25 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 3,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.25 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.87 SHGC 0.45 Simple Glazing Window,,,,0.87,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 3,GlassDoor,Metal framing (entrance door),Residential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 3,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 3,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2013,ClimateZone 3,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, +90.1-2013,ClimateZone 3,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2013,ClimateZone 3,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 3,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2013,ClimateZone 3,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 3,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2013,ClimateZone 3,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2013,ClimateZone 3,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2013,ClimateZone 3,Skylight,Glass with Curb,Nonresidential,U 0.55 SHGC 0.64 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,0.64,, +90.1-2013,ClimateZone 3,Skylight,Glass with Curb,Residential,U 0.55 SHGC 0.45 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,Skylight,Glass with Curb,Semiheated,U 1.70 SHGC 0.36 Simple Glazing Skylight,,0,2,1.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,Skylight,Plastic with Curb,Nonresidential,U 0.55 SHGC 0.45 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,Skylight,Plastic with Curb,Residential,U 0.55 SHGC 0.45 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,Skylight,Plastic with Curb,Semiheated,U 1.70 SHGC 0.36 Simple Glazing Skylight,,0,2,1.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,Skylight,Without Curb,Nonresidential,U 0.55 SHGC 0.45 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,Skylight,Without Curb,Residential,U 0.55 SHGC 0.45 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,Skylight,Without Curb,Semiheated,U 1.70 SHGC 0.36 Simple Glazing Skylight,,0,2,1.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 4,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.082,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2013,ClimateZone 4,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.06,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2013,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.42 SHGC 0.4 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.42 SHGC 0.4 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.4 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.51 SHGC 0.45 Simple Glazing Window,,,,0.51,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.73 SHGC 0.45 Simple Glazing Window,,,,0.73,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.4 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 0.81 SHGC 0.45 Simple Glazing Window,,,,0.81,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2013,ClimateZone 4,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.843,,,, +90.1-2013,ClimateZone 4,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2013,ClimateZone 4,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2013,ClimateZone 4,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 4,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2013,ClimateZone 4,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 4,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2013,ClimateZone 4,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, +90.1-2013,ClimateZone 4,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2013,ClimateZone 4,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,Skylight,Glass with Curb,Semiheated,U 1.15 SHGC 0.77 Simple Glazing Skylight,,0,2,1.15,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,Skylight,Plastic with Curb,Semiheated,U 1.15 SHGC 0.77 Simple Glazing Skylight,,0,2,1.15,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,Skylight,Without Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,Skylight,Without Curb,Semiheated,U 1.15 SHGC 0.77 Simple Glazing Skylight,,0,2,1.15,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 5,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.082,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2013,ClimateZone 5,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.055,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.055,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2013,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.32 SHGC 0.4 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.42 SHGC 0.4 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.32 SHGC 0.4 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.42 SHGC 0.4 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.4 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.62 SHGC 0.45 Simple Glazing Window,,,,0.62,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.4 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 0.7 SHGC 0.45 Simple Glazing Window,,,,0.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2013,ClimateZone 5,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2013,ClimateZone 5,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.51,,,, +90.1-2013,ClimateZone 5,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2013,ClimateZone 5,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 5,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2013,ClimateZone 5,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 5,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2013,ClimateZone 5,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, +90.1-2013,ClimateZone 5,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2013,ClimateZone 5,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.36 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.36,, +90.1-2013,ClimateZone 5,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.19 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.19,, +90.1-2013,ClimateZone 5,Skylight,Glass with Curb,Semiheated,U 0.98 SHGC 0.45 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.34 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.34,, +90.1-2013,ClimateZone 5,Skylight,Plastic with Curb,Semiheated,U 0.98 SHGC 0.27 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.27,, +90.1-2013,ClimateZone 5,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,Skylight,Without Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,Skylight,Without Curb,Semiheated,U 0.98 SHGC 0.36 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.36,, +90.1-2013,ClimateZone 6,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 6,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.031,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.06,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2013,ClimateZone 6,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2013,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.32 SHGC 0.4 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.42 SHGC 0.4 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.4 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.32 SHGC 0.4 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.42 SHGC 0.4 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.4 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.51 SHGC 0.45 Simple Glazing Window,,,,0.51,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 0.59 SHGC 0.45 Simple Glazing Window,,,,0.59,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.51,,,, +90.1-2013,ClimateZone 6,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2013,ClimateZone 6,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.434,,,, +90.1-2013,ClimateZone 6,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.671,,,, +90.1-2013,ClimateZone 6,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 6,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2013,ClimateZone 6,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 6,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, +90.1-2013,ClimateZone 6,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2013,ClimateZone 6,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2013,ClimateZone 6,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.19 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.19,, +90.1-2013,ClimateZone 6,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,Skylight,Glass with Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.36 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.36,, +90.1-2013,ClimateZone 6,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.19 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.19,, +90.1-2013,ClimateZone 6,Skylight,Plastic with Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,0.19,, +90.1-2013,ClimateZone 6,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,Skylight,Without Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,Skylight,Without Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,0.39,, +90.1-2013,ClimateZone 7,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.042,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.042,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.27,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 7,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.039,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2013,ClimateZone 7,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.044,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.044,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.042,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.072,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2013,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.51,,,, +90.1-2013,ClimateZone 7,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.671,,,, +90.1-2013,ClimateZone 7,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.434,,,, +90.1-2013,ClimateZone 7,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.671,,,, +90.1-2013,ClimateZone 7,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 7,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2013,ClimateZone 7,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 7,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2013,ClimateZone 7,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2013,ClimateZone 7,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2013,ClimateZone 7,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.27 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.27,, +90.1-2013,ClimateZone 7,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.27 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.27,, +90.1-2013,ClimateZone 7,Skylight,Glass with Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.36 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.36,, +90.1-2013,ClimateZone 7,Skylight,Plastic with Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,0.19,, +90.1-2013,ClimateZone 7,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.19 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.19,, +90.1-2013,ClimateZone 7,Skylight,Without Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,Skylight,Without Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 8,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.026,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.026,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.039,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2013,ClimateZone 8,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.048,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.039,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.032,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.048,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.039,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.032,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.06,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2013,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.434,,,, +90.1-2013,ClimateZone 8,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.671,,,, +90.1-2013,ClimateZone 8,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.424,,,, +90.1-2013,ClimateZone 8,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.373,,,, +90.1-2013,ClimateZone 8,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, +90.1-2013,ClimateZone 8,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2013,ClimateZone 8,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 8,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2013,ClimateZone 8,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2013,ClimateZone 8,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2013,ClimateZone 8,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.39 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.39,, +90.1-2013,ClimateZone 8,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.36 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.36,, +90.1-2013,ClimateZone 8,Skylight,Glass with Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.65 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.65,, +90.1-2013,ClimateZone 8,Skylight,Plastic with Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,0.27,, +90.1-2013,ClimateZone 8,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,Skylight,Without Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,Skylight,Without Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,0.39,, +90.1-2013,ClimateZone 1,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,1151,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2013,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.93 SHGC 0.25 Simple Glazing Window,,,,0.93,TRUE,TRUE,,,0.25,, +90.1-2013,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2013,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,, +90.1-2013,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2013,ClimateZone 1,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 1,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2013,ClimateZone 1,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 1,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2013,ClimateZone 1,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 1,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2013,ClimateZone 1,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 1,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2013,ClimateZone 1,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2013,ClimateZone 1,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2013,ClimateZone 1,Skylight,Glass with Curb,Nonresidential,U 0.75 SHGC 0.45 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,Skylight,Glass with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.49,, +90.1-2013,ClimateZone 1,Skylight,Glass with Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,0.49,, +90.1-2013,ClimateZone 1,Skylight,Plastic with Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.39,, +90.1-2013,ClimateZone 1,Skylight,Plastic with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,Skylight,Plastic with Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,Skylight,Without Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.68,, +90.1-2013,ClimateZone 1,Skylight,Without Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.64,, +90.1-2013,ClimateZone 1,Skylight,Without Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,0.64,, +90.1-2016,ClimateZone 1,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 1,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 1,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 1,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 1,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 1,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.1156,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2016,ClimateZone 1,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 2,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 2,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 2,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 2,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 2,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.096,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2016,ClimateZone 2,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2016,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.37 SHGC 0.25 Simple Glazing Window,,,,0.37,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.54 SHGC 0.25 Simple Glazing Window,,,,0.54,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.83 SHGC 0.25 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 0.37 SHGC 0.25 Simple Glazing Window,,,,0.37,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.54 SHGC 0.25 Simple Glazing Window,,,,0.54,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 0.77 SHGC 0.25 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.93 SHGC 0.45 Simple Glazing Window,,,,0.93,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 0.83 SHGC 0.45 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 2,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2016,ClimateZone 2,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 2,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2016,ClimateZone 2,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 2,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2016,ClimateZone 2,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 2,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2016,ClimateZone 2,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2016,ClimateZone 2,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2016,ClimateZone 2,Skylight,Glass with Curb,Nonresidential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 2,Skylight,Glass with Curb,Residential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 2,Skylight,Glass with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, +90.1-2016,ClimateZone 2,Skylight,Plastic with Curb,Nonresidential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 2,Skylight,Plastic with Curb,Residential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 2,Skylight,Plastic with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, +90.1-2016,ClimateZone 2,Skylight,Without Curb,Nonresidential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 2,Skylight,Without Curb,Residential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 2,Skylight,Without Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, +90.1-2016,ClimateZone 3,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 3,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 3,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 3,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 3,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 3,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 3,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 3,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.119,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.096,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2016,ClimateZone 3,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.077,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.072,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2016,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.33 SHGC 0.25 Simple Glazing Window,,,,0.33,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 3,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.25 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Residential,U 0.33 SHGC 0.25 Simple Glazing Window,,,,0.33,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 3,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.25 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.87 SHGC 0.45 Simple Glazing Window,,,,0.87,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 3,GlassDoor,Metal framing (entrance door),Residential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 3,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 3,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2016,ClimateZone 3,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, +90.1-2016,ClimateZone 3,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2016,ClimateZone 3,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 3,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2016,ClimateZone 3,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 3,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2016,ClimateZone 3,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2016,ClimateZone 3,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2016,ClimateZone 3,Skylight,Glass with Curb,Nonresidential,U 0.55 SHGC 0.35 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 3,Skylight,Glass with Curb,Residential,U 0.55 SHGC 0.35 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 3,Skylight,Glass with Curb,Semiheated,U 1.7 SHGC 0.55 Simple Glazing Skylight,,,,1.7,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,Skylight,Plastic with Curb,Nonresidential,U 0.55 SHGC 0.35 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 3,Skylight,Plastic with Curb,Residential,U 0.55 SHGC 0.35 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 3,Skylight,Plastic with Curb,Semiheated,U 1.7 SHGC 0.55 Simple Glazing Skylight,,,,1.7,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,Skylight,Without Curb,Nonresidential,U 0.55 SHGC 0.35 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 3,Skylight,Without Curb,Residential,U 0.55 SHGC 0.35 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 3,Skylight,Without Curb,Semiheated,U 1.7 SHGC 0.55 Simple Glazing Skylight,,,,1.7,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 4,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 4,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 4,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 4,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 4,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 4,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 4,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.082,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2016,ClimateZone 4,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.06,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2016,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.31 SHGC 0.36 Simple Glazing Window,,,,0.31,TRUE,TRUE,,,0.36,1.1, +90.1-2016,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.38 SHGC 0.36 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.36,1.1, +90.1-2016,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.31 SHGC 0.36 Simple Glazing Window,,,,0.31,TRUE,TRUE,,,0.36,1.1, +90.1-2016,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.38 SHGC 0.36 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.36,1.1, +90.1-2016,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.36 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.36,1.1, +90.1-2016,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.51 SHGC 0.45 Simple Glazing Window,,,,0.51,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.73 SHGC 0.45 Simple Glazing Window,,,,0.73,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.68 SHGC 0.36 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.36,1.1, +90.1-2016,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2016,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2016,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 0.81 SHGC 0.45 Simple Glazing Window,,,,0.81,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2016,ClimateZone 4,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.843,,,, +90.1-2016,ClimateZone 4,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2016,ClimateZone 4,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2016,ClimateZone 4,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 4,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2016,ClimateZone 4,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 4,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2016,ClimateZone 4,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, +90.1-2016,ClimateZone 4,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2016,ClimateZone 4,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 4,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 4,Skylight,Glass with Curb,Semiheated,U 1.15 SHGC 0.55 Simple Glazing Skylight,,,,1.15,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 4,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 4,Skylight,Plastic with Curb,Semiheated,U 1.15 SHGC 0.55 Simple Glazing Skylight,,,,1.15,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 4,Skylight,Without Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 4,Skylight,Without Curb,Semiheated,U 1.15 SHGC 0.55 Simple Glazing Skylight,,,,1.15,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 5,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 5,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 5,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 5,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 5,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 5,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 5,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.082,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2016,ClimateZone 5,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.055,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.055,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2016,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.31 SHGC 0.38 Simple Glazing Window,,,,0.31,TRUE,TRUE,,,0.38,1.1, +90.1-2016,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.38 SHGC 0.38 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.38,1.1, +90.1-2016,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.31 SHGC 0.38 Simple Glazing Window,,,,0.31,TRUE,TRUE,,,0.38,1.1, +90.1-2016,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.38 SHGC 0.38 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.38,1.1, +90.1-2016,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.38 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.38,1.1, +90.1-2016,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.62 SHGC 0.45 Simple Glazing Window,,,,0.62,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.68 SHGC 0.38 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.38,1.1, +90.1-2016,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2016,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2016,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 0.7 SHGC 0.45 Simple Glazing Window,,,,0.7,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2016,ClimateZone 5,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2016,ClimateZone 5,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.51,,,, +90.1-2016,ClimateZone 5,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2016,ClimateZone 5,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 5,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2016,ClimateZone 5,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 5,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2016,ClimateZone 5,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, +90.1-2016,ClimateZone 5,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2016,ClimateZone 5,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 5,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 5,Skylight,Glass with Curb,Semiheated,U 0.98 SHGC 0.55 Simple Glazing Skylight,,,,0.98,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 5,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 5,Skylight,Plastic with Curb,Semiheated,U 0.98 SHGC 0.55 Simple Glazing Skylight,,,,0.98,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 5,Skylight,Without Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 5,Skylight,Without Curb,Semiheated,U 0.98 SHGC 0.55 Simple Glazing Skylight,,,,0.98,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 6,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 6,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 6,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 6,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 6,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 6,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 6,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.031,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.06,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2016,ClimateZone 6,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2016,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.3 SHGC 0.4 Simple Glazing Window,,,,0.3,TRUE,TRUE,,,0.4,1.1, +90.1-2016,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.36 SHGC 0.4 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.4,1.1, +90.1-2016,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.68 SHGC 0.4 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.4,1.1, +90.1-2016,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.3 SHGC 0.4 Simple Glazing Window,,,,0.3,TRUE,TRUE,,,0.4,1.1, +90.1-2016,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.36 SHGC 0.4 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.4,1.1, +90.1-2016,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.4 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.4,1.1, +90.1-2016,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.51 SHGC 0.45 Simple Glazing Window,,,,0.51,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2016,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2016,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 0.59 SHGC 0.45 Simple Glazing Window,,,,0.59,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.51,,,, +90.1-2016,ClimateZone 6,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2016,ClimateZone 6,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.434,,,, +90.1-2016,ClimateZone 6,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.671,,,, +90.1-2016,ClimateZone 6,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 6,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2016,ClimateZone 6,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 6,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, +90.1-2016,ClimateZone 6,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2016,ClimateZone 6,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2016,ClimateZone 6,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 6,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 6,Skylight,Glass with Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 6,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 6,Skylight,Plastic with Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 6,Skylight,Without Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 6,Skylight,Without Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 7,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 7,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 7,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 7,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 7,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 7,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.042,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.042,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.27,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 7,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.039,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2016,ClimateZone 7,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.044,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.044,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.042,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.072,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2016,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.28 SHGC 0.45 Simple Glazing Window,,,,0.28,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.33 SHGC 0.45 Simple Glazing Window,,,,0.33,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.28 SHGC 0.45 Simple Glazing Window,,,,0.28,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.33 SHGC 0.45 Simple Glazing Window,,,,0.33,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.51,,,, +90.1-2016,ClimateZone 7,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.671,,,, +90.1-2016,ClimateZone 7,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.434,,,, +90.1-2016,ClimateZone 7,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.671,,,, +90.1-2016,ClimateZone 7,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 7,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2016,ClimateZone 7,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 7,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2016,ClimateZone 7,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2016,ClimateZone 7,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2016,ClimateZone 7,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.55 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.55 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,Skylight,Glass with Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.55 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.55 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,Skylight,Plastic with Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.55 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,Skylight,Without Curb,Residential,U 0.5 SHGC 0.55 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,Skylight,Without Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 8,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 8,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 8,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 8,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 8,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 8,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 8,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.026,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.026,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.039,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2016,ClimateZone 8,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.048,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.039,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.048,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.039,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.06,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2016,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.25 SHGC 0.45 Simple Glazing Window,,,,0.25,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.29 SHGC 0.45 Simple Glazing Window,,,,0.29,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.25 SHGC 0.45 Simple Glazing Window,,,,0.25,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.29 SHGC 0.45 Simple Glazing Window,,,,0.29,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.434,,,, +90.1-2016,ClimateZone 8,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.671,,,, +90.1-2016,ClimateZone 8,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.424,,,, +90.1-2016,ClimateZone 8,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.373,,,, +90.1-2016,ClimateZone 8,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, +90.1-2016,ClimateZone 8,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2016,ClimateZone 8,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 8,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2016,ClimateZone 8,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2016,ClimateZone 8,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2016,ClimateZone 8,Skylight,Glass with Curb,Nonresidential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,Skylight,Glass with Curb,Residential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,Skylight,Glass with Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,Skylight,Plastic with Curb,Nonresidential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,Skylight,Plastic with Curb,Residential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,Skylight,Plastic with Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,Skylight,Without Curb,Nonresidential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,Skylight,Without Curb,Residential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,Skylight,Without Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,1151,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2016,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.93 SHGC 0.45 Simple Glazing Window,,,,0.93,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.1 SHGC 0.45 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2016,ClimateZone 1,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 1,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2016,ClimateZone 1,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 1,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2016,ClimateZone 1,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 1,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2016,ClimateZone 1,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 1,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2016,ClimateZone 1,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2016,ClimateZone 1,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2016,ClimateZone 1,Skylight,Glass with Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 1,Skylight,Glass with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 1,Skylight,Glass with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, +90.1-2016,ClimateZone 1,Skylight,Plastic with Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 1,Skylight,Plastic with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 1,Skylight,Plastic with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, +90.1-2016,ClimateZone 1,Skylight,Without Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 1,Skylight,Without Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 1,Skylight,Without Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, +90.1-2019,ClimateZone 1,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 1,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 1,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 1,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 1,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 1,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.1156,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2019,ClimateZone 1,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 2,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 2,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 2,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 2,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 2,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.096,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2019,ClimateZone 2,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2019,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1,Fixed +90.1-2019,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1,Fixed +90.1-2019,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.23 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.23,1.1,Entrance door +90.1-2019,ClimateZone 2,ExteriorWindow,Fixed,Nonresidential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1, +90.1-2019,ClimateZone 2,ExteriorWindow,Operable,Nonresidential,U 0.6 SHGC 0.23 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.23,1.1, +90.1-2019,ClimateZone 2,ExteriorWindow,Entrance door,Nonresidential,U 0.77 SHGC 0.23 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.23,1.1, +90.1-2019,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1,Fixed +90.1-2019,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1,Fixed +90.1-2019,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 0.77 SHGC 0.23 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.23,1.1,Entrance door +90.1-2019,ClimateZone 2,ExteriorWindow,Fixed,Residential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1, +90.1-2019,ClimateZone 2,ExteriorWindow,Operable,Residential,U 0.6 SHGC 0.23 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.23,1.1, +90.1-2019,ClimateZone 2,ExteriorWindow,Entrance door,Residential,U 0.77 SHGC 0.23 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.23,1.1, +90.1-2019,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,,Entrance door +90.1-2019,ClimateZone 2,ExteriorWindow,Fixed,Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorWindow,Operable,Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorWindow,Entrance door,Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2019,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2019,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 2,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2019,ClimateZone 2,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 2,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2019,ClimateZone 2,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 2,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2019,ClimateZone 2,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 2,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2019,ClimateZone 2,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2019,ClimateZone 2,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2019,ClimateZone 2,Skylight,Glass with Curb,Nonresidential,U 0.65 SHGC 0.3 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 2,Skylight,Glass with Curb,Residential,U 0.65 SHGC 0.3 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 2,Skylight,Glass with Curb,Semiheated,U 0.9 SHGC 0.55 Simple Glazing Skylight,,,,0.9,TRUE,TRUE,,,0.55,, +90.1-2019,ClimateZone 2,Skylight,Plastic with Curb,Nonresidential,U 0.65 SHGC 0.3 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 2,Skylight,Plastic with Curb,Residential,U 0.65 SHGC 0.3 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 2,Skylight,Plastic with Curb,Semiheated,U 0.9 SHGC 0.55 Simple Glazing Skylight,,,,0.9,TRUE,TRUE,,,0.55,, +90.1-2019,ClimateZone 2,Skylight,Without Curb,Nonresidential,U 0.65 SHGC 0.3 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 2,Skylight,Without Curb,Residential,U 0.65 SHGC 0.3 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 2,Skylight,Without Curb,Semiheated,U 0.9 SHGC 0.55 Simple Glazing Skylight,,,,0.9,TRUE,TRUE,,,0.55,, +90.1-2019,ClimateZone 3,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 3,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 3,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 3,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 3,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 3,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 3,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 3,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.119,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.096,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2019,ClimateZone 3,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.077,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.072,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2019,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.42 SHGC 0.25 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.25,1.1,Fixed +90.1-2019,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.42 SHGC 0.25 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.25,1.1,Fixed +90.1-2019,ClimateZone 3,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.68 SHGC 0.23 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.23,1.1,Entrance door +90.1-2019,ClimateZone 3,ExteriorWindow,Fixed,Nonresidential,U 0.42 SHGC 0.25 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.25,1.1, +90.1-2019,ClimateZone 3,ExteriorWindow,Operable,Nonresidential,U 0.54 SHGC 0.23 Simple Glazing Window,,,,0.54,TRUE,TRUE,,,0.23,1.1, +90.1-2019,ClimateZone 3,ExteriorWindow,Entrance door,Nonresidential,U 0.68 SHGC 0.23 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.23,1.1, +90.1-2019,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Residential,U 0.42 SHGC 0.25 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.25,1.1,Fixed +90.1-2019,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.42 SHGC 0.25 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.25,1.1,Fixed +90.1-2019,ClimateZone 3,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.23 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.23,1.1,Entrance door +90.1-2019,ClimateZone 3,ExteriorWindow,Fixed,Residential,U 0.42 SHGC 0.25 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.25,1.1, +90.1-2019,ClimateZone 3,ExteriorWindow,Operable,Residential,U 0.54 SHGC 0.23 Simple Glazing Window,,,,0.54,TRUE,TRUE,,,0.23,1.1, +90.1-2019,ClimateZone 3,ExteriorWindow,Entrance door,Residential,U 0.68 SHGC 0.23 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.23,1.1, +90.1-2019,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 3,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,,Entrance door +90.1-2019,ClimateZone 3,ExteriorWindow,Fixed,Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorWindow,Operable,Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorWindow,Entrance door,Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,1.1, +90.1-2019,ClimateZone 3,GlassDoor,Metal framing (entrance door),Residential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,1.1, +90.1-2019,ClimateZone 3,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 3,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2019,ClimateZone 3,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, +90.1-2019,ClimateZone 3,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2019,ClimateZone 3,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 3,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2019,ClimateZone 3,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 3,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2019,ClimateZone 3,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2019,ClimateZone 3,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2019,ClimateZone 3,Skylight,Glass with Curb,Nonresidential,U 0.55 SHGC 0.3 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 3,Skylight,Glass with Curb,Residential,U 0.55 SHGC 0.3 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 3,Skylight,Glass with Curb,Semiheated,U 0.9 SHGC 0.55 Simple Glazing Skylight,,,,0.9,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,Skylight,Plastic with Curb,Nonresidential,U 0.55 SHGC 0.3 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 3,Skylight,Plastic with Curb,Residential,U 0.55 SHGC 0.3 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 3,Skylight,Plastic with Curb,Semiheated,U 0.9 SHGC 0.55 Simple Glazing Skylight,,,,0.9,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,Skylight,Without Curb,Nonresidential,U 0.55 SHGC 0.3 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 3,Skylight,Without Curb,Residential,U 0.55 SHGC 0.3 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 3,Skylight,Without Curb,Semiheated,U 0.9 SHGC 0.55 Simple Glazing Skylight,,,,0.9,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 4,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 4,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 4,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 4,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 4,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 4,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 4,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.082,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2019,ClimateZone 4,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.06,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2019,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1,Fixed +90.1-2019,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1,Fixed +90.1-2019,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1,Fixed +90.1-2019,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1,Fixed +90.1-2019,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1,Entrance door +90.1-2019,ClimateZone 4,ExteriorWindow,Fixed,Residential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1, +90.1-2019,ClimateZone 4,ExteriorWindow,Operable,Residential,U 0.45 SHGC 0.33 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.33,1.1, +90.1-2019,ClimateZone 4,ExteriorWindow,Entrance door,Residential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1, +90.1-2019,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,,Entrance door +90.1-2019,ClimateZone 4,ExteriorWindow,Fixed,Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWindow,Operable,Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWindow,Entrance door,Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1,Entrance door +90.1-2019,ClimateZone 4,ExteriorWindow,Fixed,Nonresidential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1, +90.1-2019,ClimateZone 4,ExteriorWindow,Operable,Nonresidential,U 0.45 SHGC 0.33 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.33,1.1, +90.1-2019,ClimateZone 4,ExteriorWindow,Entrance door,Nonresidential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1, +90.1-2019,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2019,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2019,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 0.81 SHGC 0.45 Simple Glazing Window,,,,0.81,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2019,ClimateZone 4,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.843,,,, +90.1-2019,ClimateZone 4,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2019,ClimateZone 4,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2019,ClimateZone 4,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 4,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2019,ClimateZone 4,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 4,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2019,ClimateZone 4,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, +90.1-2019,ClimateZone 4,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2019,ClimateZone 4,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 4,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 4,Skylight,Glass with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 4,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 4,Skylight,Plastic with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 4,Skylight,Without Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 4,Skylight,Without Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 5,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 5,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 5,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 5,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 5,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 5,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 5,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.082,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2019,ClimateZone 5,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.055,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.055,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2019,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.36 SHGC 0.38 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.38,1.1,Fixed +90.1-2019,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.36 SHGC 0.38 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.38,1.1,Fixed +90.1-2019,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.36 SHGC 0.38 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.38,1.1,Fixed +90.1-2019,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.36 SHGC 0.38 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.38,1.1,Fixed +90.1-2019,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1,Entrance door +90.1-2019,ClimateZone 5,ExteriorWindow,Fixed,Residential,U 0.36 SHGC 0.38 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.38,1.1, +90.1-2019,ClimateZone 5,ExteriorWindow,Operable,Residential,U 0.45 SHGC 0.33 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.33,1.1, +90.1-2019,ClimateZone 5,ExteriorWindow,Entrance door,Residential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1, +90.1-2019,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,,Entrance door +90.1-2019,ClimateZone 5,ExteriorWindow,Fixed,Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWindow,Operable,Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWindow,Entrance door,Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1,Entrance door +90.1-2019,ClimateZone 5,ExteriorWindow,Fixed,Nonresidential,U 0.36 SHGC 0.38 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.38,1.1, +90.1-2019,ClimateZone 5,ExteriorWindow,Operable,Nonresidential,U 0.45 SHGC 0.33 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.33,1.1, +90.1-2019,ClimateZone 5,ExteriorWindow,Entrance door,Nonresidential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1, +90.1-2019,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2019,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2019,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 0.7 SHGC 0.45 Simple Glazing Window,,,,0.7,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2019,ClimateZone 5,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2019,ClimateZone 5,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.51,,,, +90.1-2019,ClimateZone 5,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2019,ClimateZone 5,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 5,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2019,ClimateZone 5,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 5,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2019,ClimateZone 5,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, +90.1-2019,ClimateZone 5,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2019,ClimateZone 5,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 5,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 5,Skylight,Glass with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 5,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 5,Skylight,Plastic with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 5,Skylight,Without Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 5,Skylight,Without Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 6,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 6,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 6,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 6,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 6,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 6,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 6,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.031,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.06,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2019,ClimateZone 6,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2019,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.34 SHGC 0.38 Simple Glazing Window,,,,0.34,TRUE,TRUE,,,0.38,1.1,Fixed +90.1-2019,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.34 SHGC 0.38 Simple Glazing Window,,,,0.34,TRUE,TRUE,,,0.38,1.1,Fixed +90.1-2019,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.63 SHGC 0.34 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.34,1.1,Entrance door +90.1-2019,ClimateZone 6,ExteriorWindow,Fixed,Nonresidential,U 0.34 SHGC 0.38 Simple Glazing Window,,,,0.34,TRUE,TRUE,,,0.38,1.1, +90.1-2019,ClimateZone 6,ExteriorWindow,Operable,Nonresidential,U 0.42 SHGC 0.34 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.34,1.1, +90.1-2019,ClimateZone 6,ExteriorWindow,Entrance door,Nonresidential,U 0.63 SHGC 0.34 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.34,1.1, +90.1-2019,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.34 SHGC 0.38 Simple Glazing Window,,,,0.34,TRUE,TRUE,,,0.38,1.1,Fixed +90.1-2019,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.34 SHGC 0.38 Simple Glazing Window,,,,0.34,TRUE,TRUE,,,0.38,1.1,Fixed +90.1-2019,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.63 SHGC 0.34 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.34,1.1,Entrance door +90.1-2019,ClimateZone 6,ExteriorWindow,Fixed,Residential,U 0.34 SHGC 0.38 Simple Glazing Window,,,,0.34,TRUE,TRUE,,,0.38,1.1, +90.1-2019,ClimateZone 6,ExteriorWindow,Operable,Residential,U 0.42 SHGC 0.34 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.34,1.1, +90.1-2019,ClimateZone 6,ExteriorWindow,Entrance door,Residential,U 0.63 SHGC 0.34 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.34,1.1, +90.1-2019,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.39 SHGC 0.45 Simple Glazing Window,,,,0.39,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.39 SHGC 0.45 Simple Glazing Window,,,,0.39,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,,,Entrance door +90.1-2019,ClimateZone 6,ExteriorWindow,Fixed,Semiheated,U 0.39 SHGC 0.45 Simple Glazing Window,,,,0.39,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorWindow,Operable,Semiheated,U 0.48 SHGC 0.45 Simple Glazing Window,,,,0.48,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorWindow,Entrance door,Semiheated,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2019,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2019,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 0.59 SHGC 0.45 Simple Glazing Window,,,,0.59,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.51,,,, +90.1-2019,ClimateZone 6,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2019,ClimateZone 6,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.434,,,, +90.1-2019,ClimateZone 6,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.671,,,, +90.1-2019,ClimateZone 6,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 6,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2019,ClimateZone 6,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 6,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, +90.1-2019,ClimateZone 6,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2019,ClimateZone 6,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2019,ClimateZone 6,Skylight,Glass with Curb,Nonresidential,U 0.47 SHGC 0.4 Simple Glazing Skylight,,,,0.47,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 6,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 6,Skylight,Glass with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,Skylight,Plastic with Curb,Nonresidential,U 0.47 SHGC 0.4 Simple Glazing Skylight,,,,0.47,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 6,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 6,Skylight,Plastic with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,Skylight,Without Curb,Nonresidential,U 0.47 SHGC 0.4 Simple Glazing Skylight,,,,0.47,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 6,Skylight,Without Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 6,Skylight,Without Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 7,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 7,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 7,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 7,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 7,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 7,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.042,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.042,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.27,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 7,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.039,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2019,ClimateZone 7,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.044,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.044,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.042,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.072,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2019,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.29 SHGC 0.4 Simple Glazing Window,,,,0.29,TRUE,TRUE,,,0.4,1.1,Fixed +90.1-2019,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.29 SHGC 0.4 Simple Glazing Window,,,,0.29,TRUE,TRUE,,,0.4,1.1,Fixed +90.1-2019,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1,Entrance door +90.1-2019,ClimateZone 7,ExteriorWindow,Fixed,Nonresidential,U 0.29 SHGC 0.4 Simple Glazing Window,,,,0.29,TRUE,TRUE,,,0.4,1.1, +90.1-2019,ClimateZone 7,ExteriorWindow,Operable,Nonresidential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1, +90.1-2019,ClimateZone 7,ExteriorWindow,Entrance door,Nonresidential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1, +90.1-2019,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.29 SHGC 0.4 Simple Glazing Window,,,,0.29,TRUE,TRUE,,,0.4,1.1,Fixed +90.1-2019,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.29 SHGC 0.4 Simple Glazing Window,,,,0.29,TRUE,TRUE,,,0.4,1.1,Fixed +90.1-2019,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1,Entrance door +90.1-2019,ClimateZone 7,ExteriorWindow,Fixed,Residential,U 0.26 SHGC 0.4 Simple Glazing Window,,,,0.26,TRUE,TRUE,,,0.4,1.1, +90.1-2019,ClimateZone 7,ExteriorWindow,Operable,Residential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1, +90.1-2019,ClimateZone 7,ExteriorWindow,Entrance door,Residential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1, +90.1-2019,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.36 SHGC 0.45 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.36 SHGC 0.45 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 0.63 SHGC 0.45 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,,,Entrance door +90.1-2019,ClimateZone 7,ExteriorWindow,Fixed,Semiheated,U 0.36 SHGC 0.45 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorWindow,Operable,Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorWindow,Entrance door,Semiheated,U 0.63 SHGC 0.45 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, +90.1-2019,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, +90.1-2019,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.51,,,, +90.1-2019,ClimateZone 7,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.671,,,, +90.1-2019,ClimateZone 7,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.434,,,, +90.1-2019,ClimateZone 7,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.671,,,, +90.1-2019,ClimateZone 7,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 7,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2019,ClimateZone 7,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 7,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2019,ClimateZone 7,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2019,ClimateZone 7,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2019,ClimateZone 7,Skylight,Glass with Curb,Nonresidential,U 0.44 SHGC 0.55 Simple Glazing Skylight,,,,0.44,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,Skylight,Glass with Curb,Residential,U 0.44 SHGC 0.55 Simple Glazing Skylight,,,,0.44,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,Skylight,Glass with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,Skylight,Plastic with Curb,Nonresidential,U 0.44 SHGC 0.55 Simple Glazing Skylight,,,,0.44,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,Skylight,Plastic with Curb,Residential,U 0.44 SHGC 0.55 Simple Glazing Skylight,,,,0.44,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,Skylight,Plastic with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,Skylight,Without Curb,Nonresidential,U 0.44 SHGC 0.55 Simple Glazing Skylight,,,,0.44,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,Skylight,Without Curb,Residential,U 0.44 SHGC 0.55 Simple Glazing Skylight,,,,0.44,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,Skylight,Without Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 8,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 8,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 8,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 8,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 8,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 8,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 8,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.026,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.026,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.039,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2019,ClimateZone 8,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.048,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.039,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.048,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.039,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.06,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2019,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.26 SHGC 0.4 Simple Glazing Window,,,,0.26,TRUE,TRUE,,,0.4,1.1,Fixed +90.1-2019,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.26 SHGC 0.4 Simple Glazing Window,,,,0.26,TRUE,TRUE,,,0.4,1.1,Fixed +90.1-2019,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1,Entrance door +90.1-2019,ClimateZone 8,ExteriorWindow,Fixed,Nonresidential,U 0.26 SHGC 0.4 Simple Glazing Window,,,,0.26,TRUE,TRUE,,,0.4,1.1, +90.1-2019,ClimateZone 8,ExteriorWindow,Operable,Nonresidential,U 0.32 SHGC 0.36 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.36,1.1, +90.1-2019,ClimateZone 8,ExteriorWindow,Entrance door,Nonresidential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1, +90.1-2019,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.26 SHGC 0.4 Simple Glazing Window,,,,0.26,TRUE,TRUE,,,0.4,1.1,Fixed +90.1-2019,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.26 SHGC 0.4 Simple Glazing Window,,,,0.26,TRUE,TRUE,,,0.4,1.1,Fixed +90.1-2019,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1,Entrance door +90.1-2019,ClimateZone 8,ExteriorWindow,Fixed,Residential,U 0.26 SHGC 0.4 Simple Glazing Window,,,,0.26,TRUE,TRUE,,,0.4,1.1, +90.1-2019,ClimateZone 8,ExteriorWindow,Operable,Residential,U 0.32 SHGC 0.36 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.36,1.1, +90.1-2019,ClimateZone 8,ExteriorWindow,Entrance door,Residential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1, +90.1-2019,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.36 SHGC 0.45 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.36 SHGC 0.45 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 0.63 SHGC 0.45 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,,,Entrance door +90.1-2019,ClimateZone 8,ExteriorWindow,Fixed,Semiheated,U 0.36 SHGC 0.45 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorWindow,Operable,Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorWindow,Metal framing (entrance door),Semiheated,U 0.63 SHGC 0.45 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, +90.1-2019,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, +90.1-2019,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.434,,,, +90.1-2019,ClimateZone 8,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.671,,,, +90.1-2019,ClimateZone 8,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.424,,,, +90.1-2019,ClimateZone 8,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.373,,,, +90.1-2019,ClimateZone 8,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, +90.1-2019,ClimateZone 8,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2019,ClimateZone 8,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 8,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2019,ClimateZone 8,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2019,ClimateZone 8,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2019,ClimateZone 8,Skylight,Glass with Curb,Nonresidential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,Skylight,Glass with Curb,Residential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,Skylight,Glass with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,Skylight,Plastic with Curb,Nonresidential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,Skylight,Plastic with Curb,Residential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,Skylight,Plastic with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,Skylight,Without Curb,Nonresidential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,Skylight,Without Curb,Residential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,Skylight,Without Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,1151,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2019,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.5 SHGC 0.23 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.23,1.1,Fixed +90.1-2019,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.5 SHGC 0.23 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.23,1.1,Fixed +90.1-2019,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.83 SHGC 0.21 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.21,1.1,Entrance door +90.1-2019,ClimateZone 1,ExteriorWindow,Fixed,Nonresidential,U 0.5 SHGC 0.23 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.23,1.1, +90.1-2019,ClimateZone 1,ExteriorWindow,Operable,Nonresidential,U 0.62 SHGC 0.21 Simple Glazing Window,,,,0.62,TRUE,TRUE,,,0.21,1.1, +90.1-2019,ClimateZone 1,ExteriorWindow,Entrance door,Nonresidential,U 0.83 SHGC 0.21 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.21,1.1, +90.1-2019,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 0.5 SHGC 0.23 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.23,1.1,Fixed +90.1-2019,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.5 SHGC 0.23 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.23,1.1,Fixed +90.1-2019,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 0.83 SHGC 0.21 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.21,1.1,Entrance door +90.1-2019,ClimateZone 1,ExteriorWindow,Fixed,Residential,U 0.5 SHGC 0.23 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.23,1.1, +90.1-2019,ClimateZone 1,ExteriorWindow,Operable,Residential,U 0.62 SHGC 0.21 Simple Glazing Window,,,,0.62,TRUE,TRUE,,,0.21,1.1, +90.1-2019,ClimateZone 1,ExteriorWindow,Entrance door,Residential,U 0.83 SHGC 0.21 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.21,1.1, +90.1-2019,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.1 SHGC 0.45 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,,,Entrance door +90.1-2019,ClimateZone 1,ExteriorWindow,Fixed,Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorWindow,Operable,Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorWindow,Entrance door,Semiheated,U 1.1 SHGC 0.45 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2019,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2019,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2019,ClimateZone 1,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 1,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2019,ClimateZone 1,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 1,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2019,ClimateZone 1,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 1,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2019,ClimateZone 1,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 1,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2019,ClimateZone 1,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2019,ClimateZone 1,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2019,ClimateZone 1,Skylight,Glass with Curb,Nonresidential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 1,Skylight,Glass with Curb,Residential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 1,Skylight,Glass with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, +90.1-2019,ClimateZone 1,Skylight,Plastic with Curb,Nonresidential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 1,Skylight,Plastic with Curb,Residential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 1,Skylight,Plastic with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, +90.1-2019,ClimateZone 1,Skylight,Without Curb,Nonresidential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 1,Skylight,Without Curb,Residential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 1,Skylight,Without Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, +90.1-2016,ClimateZone 0,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 0,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 0,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 0,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 0,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 0,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.115,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2016,ClimateZone 0,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2016,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.32 SHGC 0.22 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.22,1.1, +90.1-2016,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1, +90.1-2016,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.83 SHGC 0.22 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.22,1.1, +90.1-2016,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 0.32 SHGC 0.22 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.22,1.1, +90.1-2016,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1, +90.1-2016,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 0.83 SHGC 0.22 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.22,1.1, +90.1-2016,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.93 SHGC 0.45 Simple Glazing Window,,,,0.93,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.1 SHGC 0.45 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2016,ClimateZone 0,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 0,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2016,ClimateZone 0,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 0,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2016,ClimateZone 0,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 0,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2016,ClimateZone 0,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 0,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2016,ClimateZone 0,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2016,ClimateZone 0,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2016,ClimateZone 0,Skylight,Glass with Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 0,Skylight,Glass with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 0,Skylight,Glass with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, +90.1-2016,ClimateZone 0,Skylight,Plastic with Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 0,Skylight,Plastic with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 0,Skylight,Plastic with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, +90.1-2016,ClimateZone 0,Skylight,Without Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 0,Skylight,Without Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 0,Skylight,Without Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, +90.1-2019,ClimateZone 0,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 0,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 0,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 0,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 0,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 0,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.115,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2019,ClimateZone 0,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2019,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1,Fixed +90.1-2019,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1,Fixed +90.1-2019,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.83 SHGC 0.2 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.2,1.1,Entrance door +90.1-2019,ClimateZone 0,ExteriorWindow,Fixed,Nonresidential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1, +90.1-2019,ClimateZone 0,ExteriorWindow,Operable,Nonresidential,U 0.62 SHGC 0.2 Simple Glazing Window,,,,0.62,TRUE,TRUE,,,0.2,1.1, +90.1-2019,ClimateZone 0,ExteriorWindow,Entrance door,Nonresidential,U 0.83 SHGC 0.2 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.2,1.1, +90.1-2019,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1,Fixed +90.1-2019,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1,Fixed +90.1-2019,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 0.83 SHGC 0.2 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.2,1.1,Entrance door +90.1-2019,ClimateZone 0,ExteriorWindow,Fixed,Residential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1, +90.1-2019,ClimateZone 0,ExteriorWindow,Operable,Residential,U 0.62 SHGC 0.2 Simple Glazing Window,,,,0.62,TRUE,TRUE,,,0.2,1.1, +90.1-2019,ClimateZone 0,ExteriorWindow,Entrance door,Residential,U 0.83 SHGC 0.2 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.2,1.1, +90.1-2019,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.1 SHGC 0.45 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,,,Entrance door +90.1-2019,ClimateZone 0,ExteriorWindow,Fixed,Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorWindow,Operable,Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorWindow,Entrance door,Semiheated,U 1.1 SHGC 0.45 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2019,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2019,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2019,ClimateZone 0,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 0,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2019,ClimateZone 0,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 0,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2019,ClimateZone 0,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 0,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2019,ClimateZone 0,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 0,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2019,ClimateZone 0,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2019,ClimateZone 0,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2019,ClimateZone 0,Skylight,Glass with Curb,Nonresidential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 0,Skylight,Glass with Curb,Residential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 0,Skylight,Glass with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,Skylight,Plastic with Curb,Nonresidential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 0,Skylight,Plastic with Curb,Residential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 0,Skylight,Plastic with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,Skylight,Without Curb,Nonresidential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 0,Skylight,Without Curb,Residential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 0,Skylight,Without Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 0,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,1.282,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.614,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,1.28,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2004,ClimateZone 0,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,1.18,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 0,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 0,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 0,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 0,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 0,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 0,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 0,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 0,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 0,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 0,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.36 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 0,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 0,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.16 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.16,, +90.1-2004,ClimateZone 0,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.34 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.34,, +90.1-2004,ClimateZone 0,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.27,, +90.1-2004,ClimateZone 0,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.27,, +90.1-2004,ClimateZone 0,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 0,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.065,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.063,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.65,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,1.28,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2007,ClimateZone 0,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,1.18,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2007,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 0,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2007,ClimateZone 0,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 0,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2007,ClimateZone 0,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 0,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2007,ClimateZone 0,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 0,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 0,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 0,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 0,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.49 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.49,, +90.1-2007,ClimateZone 0,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.49,, +90.1-2007,ClimateZone 0,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.39 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.39,, +90.1-2007,ClimateZone 0,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.34 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.77,, +90.1-2007,ClimateZone 0,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.77,, +90.1-2007,ClimateZone 0,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.62,, +90.1-2007,ClimateZone 0,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 0,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.065,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.063,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.065,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.167,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2010,ClimateZone 0,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.093,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.093,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2010,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 0,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 0,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2010,ClimateZone 0,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 0,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2010,ClimateZone 0,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 0,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2010,ClimateZone 0,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 0,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 0,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 0,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 0,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.19,, +90.1-2010,ClimateZone 0,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.34 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.36,, +90.1-2010,ClimateZone 0,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, +90.1-2010,ClimateZone 0,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, +90.1-2010,ClimateZone 0,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.39,, +90.1-2013,ClimateZone 0,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 0,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.1156,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2013,ClimateZone 0,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2013,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.93 SHGC 0.25 Simple Glazing Window,,,,0.93,TRUE,TRUE,,,0.25,, +90.1-2013,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2013,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,, +90.1-2013,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2013,ClimateZone 0,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 0,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2013,ClimateZone 0,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 0,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2013,ClimateZone 0,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 0,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2013,ClimateZone 0,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 0,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2013,ClimateZone 0,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2013,ClimateZone 0,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2013,ClimateZone 0,Skylight,Glass with Curb,Nonresidential,U 0.75 SHGC 0.45 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,Skylight,Glass with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.49,, +90.1-2013,ClimateZone 0,Skylight,Glass with Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,0.49,, +90.1-2013,ClimateZone 0,Skylight,Plastic with Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.39,, +90.1-2013,ClimateZone 0,Skylight,Plastic with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,Skylight,Plastic with Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,Skylight,Without Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.68,, +90.1-2013,ClimateZone 0,Skylight,Without Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.64,, +90.1-2013,ClimateZone 0,Skylight,Without Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,0.64,, diff --git a/data/openstudio_standards_data/initial_data/general_building_space_type.json b/data/openstudio_standards_data/initial_data/general_building_space_type.json new file mode 100644 index 0000000000..2b14fa77c2 --- /dev/null +++ b/data/openstudio_standards_data/initial_data/general_building_space_type.json @@ -0,0 +1,898 @@ +[ + { + "id": 1, + "space_type": "chapel - visually impaired", + "lighting_subspace_type": "chapel_visually_impaired", + "ventilation_subspace_type": "public_assembly_spaces_religious_workshop", + "plug_load_subspace_type": null + }, + { + "id": 2, + "space_type": "recreation/common living - visually impaired", + "lighting_subspace_type": "recreation_common_living_visually_impaired", + "ventilation_subspace_type": "hotels_motels_resorts_dormitories_multi_purpose_assembly", + "plug_load_subspace_type": null + }, + { + "id": 3, + "space_type": "atrium < 20 ft height", + "lighting_subspace_type": "atrium_low", + "ventilation_subspace_type": "office_buildings_main_entry_lobbies", + "plug_load_subspace_type": "atrium < 20 ft height" + }, + { + "id": 4, + "space_type": "atrium >= 20 ft and <= 40 ft in height", + "lighting_subspace_type": "atrium_medium", + "ventilation_subspace_type": "office_buildings_main_entry_lobbies", + "plug_load_subspace_type": "atrium >= 20 ft and <= 40 ft in height" + }, + { + "id": 5, + "space_type": "atrium > 40 ft height", + "lighting_subspace_type": "atrium_high", + "ventilation_subspace_type": "office_buildings_main_entry_lobbies", + "plug_load_subspace_type": "atrium > 40 ft height" + }, + { + "id": 6, + "space_type": "audience seating - convention center", + "lighting_subspace_type": "audience_seating_convention_center", + "ventilation_subspace_type": "public_assembly_spaces_auditorium_seating_area", + "plug_load_subspace_type": "audience seating - convention center" + }, + { + "id": 7, + "space_type": "audience seating - exercise center", + "lighting_subspace_type": "audience_seating_exercise_center", + "ventilation_subspace_type": "sports_entertainment_spectator_areas", + "plug_load_subspace_type": "audience seating - exercise center" + }, + { + "id": 8, + "space_type": "audience seating - all other", + "lighting_subspace_type": "audience_seating_general", + "ventilation_subspace_type": "public_assembly_spaces_auditorium_seating_area", + "plug_load_subspace_type": "audience seating - all other" + }, + { + "id": 9, + "space_type": "audience seating - auditorium", + "lighting_subspace_type": "audience_seating_auditorium", + "ventilation_subspace_type": "public_assembly_spaces_auditorium_seating_area", + "plug_load_subspace_type": "audience seating - auditorium" + }, + { + "id": 10, + "space_type": "audience seating - gymnasium", + "lighting_subspace_type": "audience_seating_gymnasium", + "ventilation_subspace_type": "sports_entertainment_spectator_areas", + "plug_load_subspace_type": "audience seating - gymnasium" + }, + { + "id": 11, + "space_type": "audience seating - sports arena", + "lighting_subspace_type": "audience_seating_sports_arena", + "ventilation_subspace_type": "sports_entertainment_spectator_areas", + "plug_load_subspace_type": "audience seating - sports arena" + }, + { + "id": 12, + "space_type": "audience seating - motion picture theater", + "lighting_subspace_type": "audience_seating_motion_picture_theater", + "ventilation_subspace_type": "public_assembly_spaces_auditorium_seating_area", + "plug_load_subspace_type": "audience seating - motion picture theater" + }, + { + "id": 13, + "space_type": "audience seating - penitentiary", + "lighting_subspace_type": "audience_seating_penitentiary", + "ventilation_subspace_type": "public_assembly_spaces_auditorium_seating_area", + "plug_load_subspace_type": null + }, + { + "id": 14, + "space_type": "audience seating - performing arts theater", + "lighting_subspace_type": "audience_seating_performing_arts_theater", + "ventilation_subspace_type": "public_assembly_spaces_auditorium_seating_area", + "plug_load_subspace_type": "audience seating - performing arts theater" + }, + { + "id": 15, + "space_type": "audience seating - religious facility", + "lighting_subspace_type": "audience_seating_religious_facility", + "ventilation_subspace_type": "public_assembly_spaces_auditorium_seating_area", + "plug_load_subspace_type": "audience seating - religious facility" + }, + { + "id": 16, + "space_type": "audience seating - transportation facility", + "lighting_subspace_type": "audience_seating_transportation", + "ventilation_subspace_type": "public_assembly_spaces_auditorium_seating_area", + "plug_load_subspace_type": null + }, + { + "id": 17, + "space_type": "automotive", + "lighting_subspace_type": "automotive", + "ventilation_subspace_type": "miscellaneous_spaces_transportation_waiting", + "plug_load_subspace_type": null + }, + { + "id": 18, + "space_type": "banking activity", + "lighting_subspace_type": "banking_activity", + "ventilation_subspace_type": "miscellaneous_spaces_banks_bank_lobbies", + "plug_load_subspace_type": "banking activity" + }, + { + "id": 19, + "space_type": "classroom/lecture/training - all other", + "lighting_subspace_type": "classroom_lecture_training_general", + "ventilation_subspace_type": "educational_facilities_classroom_old", + "plug_load_subspace_type": "classroom/lecture/training - all other" + }, + { + "id": 20, + "space_type": "classroom/lecture/training - penitentiary", + "lighting_subspace_type": "classroom_lecture_training_penitentiary", + "ventilation_subspace_type": "correctional_facilities_dayroom", + "plug_load_subspace_type": "classroom/lecture/training - penitentiary" + }, + { + "id": 21, + "space_type": "classroom - laboratory or shop", + "lighting_subspace_type": "laboratory_classroom", + "ventilation_subspace_type": "educational_facilities_university_college_laboratories", + "plug_load_subspace_type": null + }, + { + "id": 22, + "space_type": "classroom/lecture/training - preschool to 12th", + "lighting_subspace_type": "classroom_lecture_training_general", + "ventilation_subspace_type": "educational_facilities_classroom_young", + "plug_load_subspace_type": "classroom/lecture/training - preschool to 12th" + }, + { + "id": 23, + "space_type": "computer room", + "lighting_subspace_type": "computer_room", + "ventilation_subspace_type": "miscellaneous_spaces_computer", + "plug_load_subspace_type": "computer room" + }, + { + "id": 24, + "space_type": "conference/meeting/multipurpose", + "lighting_subspace_type": "conference_meeting_multipurpose", + "ventilation_subspace_type": "general_conference_meeting", + "plug_load_subspace_type": "conference/meeting/multipurpose" + }, + { + "id": 25, + "space_type": "confinement cells", + "lighting_subspace_type": "confinement_cells", + "ventilation_subspace_type": "correctional_facilities_cell", + "plug_load_subspace_type": "confinement cells" + }, + { + "id": 26, + "space_type": "exhibit - convention center", + "lighting_subspace_type": "exhibit_convention_center", + "ventilation_subspace_type": "public_assembly_spaces_museums_galleries", + "plug_load_subspace_type": "exhibit - convention center" + }, + { + "id": 27, + "space_type": "copy/print", + "lighting_subspace_type": "copy_print", + "ventilation_subspace_type": "office_buildings_telephone_data_entry", + "plug_load_subspace_type": null + }, + { + "id": 28, + "space_type": "corridor for visually impaired", + "lighting_subspace_type": "corridor_visually_impaired", + "ventilation_subspace_type": "general_conference_corridors", + "plug_load_subspace_type": null + }, + { + "id": 29, + "space_type": "corridor - hospital", + "lighting_subspace_type": "corridor_hospital", + "ventilation_subspace_type": "general_conference_corridors", + "plug_load_subspace_type": "corridor - hospital" + }, + { + "id": 30, + "space_type": "corridor - manufacturing facility", + "lighting_subspace_type": "corridor_manufacturing_facility", + "ventilation_subspace_type": "general_conference_corridors", + "plug_load_subspace_type": "corridor - manufacturing facility" + }, + { + "id": 31, + "space_type": "corridor - all other", + "lighting_subspace_type": "corridor_general", + "ventilation_subspace_type": "general_conference_corridors", + "plug_load_subspace_type": "corridor - all other" + }, + { + "id": 32, + "space_type": "courtroom", + "lighting_subspace_type": "courtroom", + "ventilation_subspace_type": "public_assembly_spaces_courtrooms", + "plug_load_subspace_type": "courtroom" + }, + { + "id": 33, + "space_type": "dining - all other", + "lighting_subspace_type": "dining_general", + "ventilation_subspace_type": "food_beverage_service_restaurant_dining_rooms", + "plug_load_subspace_type": "dining - all other" + }, + { + "id": 34, + "space_type": "dining - bar/lounge/leisure", + "lighting_subspace_type": "dining_bar_lounge_leisure", + "ventilation_subspace_type": "food_beverage_service_bars_cocktail_lounges", + "plug_load_subspace_type": "dining - bar/lounge/leisure" + }, + { + "id": 35, + "space_type": "dining - cafeteria/fast food", + "lighting_subspace_type": "dining_cafeteria_fast_food", + "ventilation_subspace_type": "food_beverage_service_cafeteria_fast_food_dining", + "plug_load_subspace_type": "dining - cafeteria/fast food" + }, + { + "id": 36, + "space_type": "dining for visually impaired", + "lighting_subspace_type": "dining_visually_impaired", + "ventilation_subspace_type": "food_beverage_service_restaurant_dining_rooms", + "plug_load_subspace_type": null + }, + { + "id": 37, + "space_type": "dining - family", + "lighting_subspace_type": "dining_family", + "ventilation_subspace_type": "food_beverage_service_restaurant_dining_rooms", + "plug_load_subspace_type": "dining - family" + }, + { + "id": 38, + "space_type": "dining - penitentiary", + "lighting_subspace_type": "dining_penitentiary", + "ventilation_subspace_type": "food_beverage_service_restaurant_dining_rooms", + "plug_load_subspace_type": "dining - penitentiary" + }, + { + "id": 39, + "space_type": "dining - hotel", + "lighting_subspace_type": "dining_hotel", + "ventilation_subspace_type": "food_beverage_service_restaurant_dining_rooms", + "plug_load_subspace_type": null + }, + { + "id": 40, + "space_type": "dining - motel", + "lighting_subspace_type": "dining_motel", + "ventilation_subspace_type": "food_beverage_service_restaurant_dining_rooms", + "plug_load_subspace_type": null + }, + { + "id": 41, + "space_type": "dormitory - living quarters", + "lighting_subspace_type": "dormitory_living_quarters", + "ventilation_subspace_type": "hotels_motels_resorts_dormitories_bedroom_living_room", + "plug_load_subspace_type": "dormitory - living quarters" + }, + { + "id": 42, + "space_type": "electrical/mechanical", + "lighting_subspace_type": "electrical_mechanical", + "ventilation_subspace_type": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", + "plug_load_subspace_type": "electrical/mechanical" + }, + { + "id": 43, + "space_type": "emergency vehicle garage", + "lighting_subspace_type": "emergency_vehicle_garage", + "ventilation_subspace_type": "miscellaneous_spaces_transportation_waiting", + "plug_load_subspace_type": "emergency vehicle garage" + }, + { + "id": 44, + "space_type": "firestation - sleeping quarters", + "lighting_subspace_type": "firestation_sleeping_quarters", + "ventilation_subspace_type": "hotels_motels_resorts_dormitories_barracks_sleeping_areas", + "plug_load_subspace_type": "firestation - sleeping quarters" + }, + { + "id": 45, + "space_type": "kitchen", + "lighting_subspace_type": "kitchen", + "ventilation_subspace_type": "food_beverage_service_kitchen", + "plug_load_subspace_type": "kitchen" + }, + { + "id": 46, + "space_type": "guest room", + "lighting_subspace_type": "guest_room", + "ventilation_subspace_type": "hotels_motels_resorts_dormitories_barracks_sleeping_areas", + "plug_load_subspace_type": "guest room" + }, + { + "id": 47, + "space_type": "gymnasium exercise area", + "lighting_subspace_type": "gymnasium_exercise_area", + "ventilation_subspace_type": "sports_entertainment_gym_stadium", + "plug_load_subspace_type": "gymnasium exercise area" + }, + { + "id": 48, + "space_type": "gymnasium playing area", + "lighting_subspace_type": "gymnasium_playing_area", + "ventilation_subspace_type": "sports_entertainment_gym_stadium", + "plug_load_subspace_type": "gymnasium playing area" + }, + { + "id": 49, + "space_type": "emergency room", + "lighting_subspace_type": "emergency_room", + "ventilation_subspace_type": "outpatient_health_care_facilities_general_examination_room", + "plug_load_subspace_type": "emergency room" + }, + { + "id": 50, + "space_type": "exam/treatment", + "lighting_subspace_type": "exam_treatment", + "ventilation_subspace_type": "outpatient_health_care_facilities_general_examination_room", + "plug_load_subspace_type": "exam/treatment" + }, + { + "id": 51, + "space_type": "imaging", + "lighting_subspace_type": "imaging", + "ventilation_subspace_type": "outpatient_health_care_facilities_class_1_imaging_rooms", + "plug_load_subspace_type": null + }, + { + "id": 52, + "space_type": "medical supply", + "lighting_subspace_type": "medical_supply", + "ventilation_subspace_type": "miscellaneous_spaces_pharmacy", + "plug_load_subspace_type": null + }, + { + "id": 53, + "space_type": "nursery", + "lighting_subspace_type": "nursery", + "ventilation_subspace_type": "outpatient_health_care_facilities_psychiatric_consultation_room", + "plug_load_subspace_type": null + }, + { + "id": 54, + "space_type": "nurses station", + "lighting_subspace_type": "nurses_station", + "ventilation_subspace_type": "outpatient_health_care_facilities_psychiatric_consultation_room", + "plug_load_subspace_type": "nurses station" + }, + { + "id": 55, + "space_type": "operating room", + "lighting_subspace_type": "operating_room", + "ventilation_subspace_type": "outpatient_health_care_facilities_general_examination_room", + "plug_load_subspace_type": "operating room" + }, + { + "id": 56, + "space_type": "patient room", + "lighting_subspace_type": "patient_room", + "ventilation_subspace_type": "outpatient_health_care_facilities_physical_therapy_individual_room", + "plug_load_subspace_type": "patient room" + }, + { + "id": 57, + "space_type": "physical therapy", + "lighting_subspace_type": "physical_therapy", + "ventilation_subspace_type": "outpatient_health_care_facilities_physical_therapy_exercise_area", + "plug_load_subspace_type": "physical therapy" + }, + { + "id": 58, + "space_type": "recovery", + "lighting_subspace_type": "recovery", + "ventilation_subspace_type": "outpatient_health_care_facilities_urgent_care_examination_room", + "plug_load_subspace_type": null + }, + { + "id": 59, + "space_type": "judges chambers", + "lighting_subspace_type": "judges_chambers", + "ventilation_subspace_type": "public_assembly_spaces_legislative_chambers", + "plug_load_subspace_type": "judges chambers" + }, + { + "id": 60, + "space_type": "laboratory", + "lighting_subspace_type": "laboratory_all_other", + "ventilation_subspace_type": "educational_facilities_science_laboratories", + "plug_load_subspace_type": "laboratory" + }, + { + "id": 61, + "space_type": "library - reading", + "lighting_subspace_type": "library_reading", + "ventilation_subspace_type": "public_assembly_spaces_libraries", + "plug_load_subspace_type": "library - reading" + }, + { + "id": 62, + "space_type": "library - stacks", + "lighting_subspace_type": "library_stacks", + "ventilation_subspace_type": "public_assembly_spaces_libraries", + "plug_load_subspace_type": "library - stacks" + }, + { + "id": 63, + "space_type": "library - cataloging", + "lighting_subspace_type": "library_cataloging", + "ventilation_subspace_type": "public_assembly_spaces_libraries", + "plug_load_subspace_type": "library - cataloging" + }, + { + "id": 64, + "space_type": "loading dock", + "lighting_subspace_type": "loading_dock", + "ventilation_subspace_type": "miscellaneous_spaces_sorting_packing_light_assembly", + "plug_load_subspace_type": null + }, + { + "id": 65, + "space_type": "lobby - all other", + "lighting_subspace_type": "lobby_general", + "ventilation_subspace_type": "public_assembly_spaces_lobbies", + "plug_load_subspace_type": "lobby - all other" + }, + { + "id": 66, + "space_type": "lobby - elevator", + "lighting_subspace_type": "lobby_elevator", + "ventilation_subspace_type": "public_assembly_spaces_lobbies", + "plug_load_subspace_type": "lobby - elevator" + }, + { + "id": 67, + "space_type": "lobby for visually impaired", + "lighting_subspace_type": "lobby_visually_impaired", + "ventilation_subspace_type": "public_assembly_spaces_lobbies", + "plug_load_subspace_type": null + }, + { + "id": 68, + "space_type": "lobby - hotel", + "lighting_subspace_type": "lobby_hotel", + "ventilation_subspace_type": "hotels_motels_resorts_dormitories_lobbies_prefunction", + "plug_load_subspace_type": "lobby - hotel" + }, + { + "id": 69, + "space_type": "lobby - motion picture theater", + "lighting_subspace_type": "lobby_motion_picture_theater", + "ventilation_subspace_type": "public_assembly_spaces_lobbies", + "plug_load_subspace_type": "lobby - motion picture theater" + }, + { + "id": 70, + "space_type": "lobby - performing arts theater", + "lighting_subspace_type": "lobby_performing_arts_theater", + "ventilation_subspace_type": "public_assembly_spaces_lobbies", + "plug_load_subspace_type": "lobby - performing arts theater" + }, + { + "id": 71, + "space_type": "locker room", + "lighting_subspace_type": "locker_room", + "ventilation_subspace_type": "general_break_rooms", + "plug_load_subspace_type": "locker room" + }, + { + "id": 72, + "space_type": "lounge/breakroom - all other", + "lighting_subspace_type": "lounge_breakroom_general", + "ventilation_subspace_type": "general_break_rooms", + "plug_load_subspace_type": "lounge/breakroom - all other" + }, + { + "id": 73, + "space_type": "lounge/breakroom - healthcare facility", + "lighting_subspace_type": "lounge_breakroom_healthcare_facility", + "ventilation_subspace_type": "general_break_rooms", + "plug_load_subspace_type": "lounge/breakroom - healthcare facility" + }, + { + "id": 74, + "space_type": "laundry/washing", + "lighting_subspace_type": "laundry_washing", + "ventilation_subspace_type": "hotels_motels_resorts_dormitories_laundry_rooms", + "plug_load_subspace_type": "laundry/washing" + }, + { + "id": 75, + "space_type": "detailed manufacuring", + "lighting_subspace_type": "detailed_manufacuring", + "ventilation_subspace_type": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", + "plug_load_subspace_type": null + }, + { + "id": 76, + "space_type": "manufacturing equipment room", + "lighting_subspace_type": "manufacturing_equipment_room", + "ventilation_subspace_type": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", + "plug_load_subspace_type": "manufacturing equipment room" + }, + { + "id": 77, + "space_type": "manufacturing extra high bay", + "lighting_subspace_type": "manufacturing_extra_high_bay", + "ventilation_subspace_type": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", + "plug_load_subspace_type": null + }, + { + "id": 78, + "space_type": "manufacturing high bay", + "lighting_subspace_type": "manufacturing_high_bay", + "ventilation_subspace_type": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", + "plug_load_subspace_type": null + }, + { + "id": 79, + "space_type": "manufacturing low bay", + "lighting_subspace_type": "manufacturing_low_bay", + "ventilation_subspace_type": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", + "plug_load_subspace_type": "manufacturing low bay" + }, + { + "id": 80, + "space_type": "manufacturing control", + "lighting_subspace_type": "manufacturing_control", + "ventilation_subspace_type": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", + "plug_load_subspace_type": null + }, + { + "id": 81, + "space_type": "museum exhibit area", + "lighting_subspace_type": "museum_exhibit_area", + "ventilation_subspace_type": "public_assembly_spaces_museums_galleries", + "plug_load_subspace_type": "museum exhibit area" + }, + { + "id": 82, + "space_type": "museum restoration", + "lighting_subspace_type": "museum_restoration", + "ventilation_subspace_type": "public_assembly_spaces_museums_galleries", + "plug_load_subspace_type": "museum restoration" + }, + { + "id": 83, + "space_type": "performing arts dressing room", + "lighting_subspace_type": "performing_arts_dressing_room", + "ventilation_subspace_type": "retail_mall_common_areas", + "plug_load_subspace_type": "performing arts dressing room" + }, + { + "id": 84, + "space_type": "office - enclosed <= 250 sf", + "lighting_subspace_type": "office_enclosed_small", + "ventilation_subspace_type": "office_buildings_office_space", + "plug_load_subspace_type": "office - enclosed <= 250 sf" + }, + { + "id": 85, + "space_type": "office - enclosed > 250 sf", + "lighting_subspace_type": "office_enclosed_large", + "ventilation_subspace_type": "office_buildings_office_space", + "plug_load_subspace_type": "office - enclosed > 250 sf" + }, + { + "id": 86, + "space_type": "office - open", + "lighting_subspace_type": "office_open", + "ventilation_subspace_type": "office_buildings_office_space", + "plug_load_subspace_type": "office - open" + }, + { + "id": 87, + "space_type": "parking area, interior", + "lighting_subspace_type": "parking_area_interior", + "ventilation_subspace_type": "miscellaneous_spaces_transportation_waiting", + "plug_load_subspace_type": "parking area, interior" + }, + { + "id": 88, + "space_type": "pharmacy", + "lighting_subspace_type": "pharmacy", + "ventilation_subspace_type": "miscellaneous_spaces_pharmacy", + "plug_load_subspace_type": "pharmacy" + }, + { + "id": 89, + "space_type": "post office - sorting area", + "lighting_subspace_type": "post_office_sorting_area", + "ventilation_subspace_type": "miscellaneous_spaces_sorting_packing_light_assembly", + "plug_load_subspace_type": "post office - sorting area" + }, + { + "id": 90, + "space_type": "fellowship hall - religious facility", + "lighting_subspace_type": "fellowship_hall_religious_facility", + "ventilation_subspace_type": "public_assembly_spaces_religious_workshop", + "plug_load_subspace_type": "fellowship hall - religious facility" + }, + { + "id": 91, + "space_type": "worship/pulpit/choir area", + "lighting_subspace_type": "worship_pulpit_choir_area", + "ventilation_subspace_type": "public_assembly_spaces_religious_workshop", + "plug_load_subspace_type": "worship/pulpit/choir area" + }, + { + "id": 92, + "space_type": "restroom - all other", + "lighting_subspace_type": "restroom_all_other", + "ventilation_subspace_type": null, + "plug_load_subspace_type": "restroom - all other" + }, + { + "id": 93, + "space_type": "restroom - visually impaired", + "lighting_subspace_type": "restroom_visually_impaired", + "ventilation_subspace_type": null, + "plug_load_subspace_type": null + }, + { + "id": 94, + "space_type": "retail dressing room", + "lighting_subspace_type": "retail_dressing_room", + "ventilation_subspace_type": "retail_mall_common_areas", + "plug_load_subspace_type": null + }, + { + "id": 95, + "space_type": "retail mall concourse", + "lighting_subspace_type": "retail_mall_concourse", + "ventilation_subspace_type": "retail_mall_common_areas", + "plug_load_subspace_type": null + }, + { + "id": 96, + "space_type": "seating area, general", + "lighting_subspace_type": "seating_area_general", + "ventilation_subspace_type": "public_assembly_spaces_auditorium_seating_area", + "plug_load_subspace_type": "seating area, general" + }, + { + "id": 97, + "space_type": "sports arena playing area, class I", + "lighting_subspace_type": "sports_arena_playing_area_class_I", + "ventilation_subspace_type": "sports_entertainment_sports_arena", + "plug_load_subspace_type": null + }, + { + "id": 98, + "space_type": "sports arena playing area, class II", + "lighting_subspace_type": "sports_arena_playing_area_class_II", + "ventilation_subspace_type": "sports_entertainment_sports_arena", + "plug_load_subspace_type": "sports arena playing area, class II" + }, + { + "id": 99, + "space_type": "sports arena playing area, class III", + "lighting_subspace_type": "sports_arena_playing_area_class_III", + "ventilation_subspace_type": "sports_entertainment_sports_arena", + "plug_load_subspace_type": null + }, + { + "id": 100, + "space_type": "sports arena playing area, class IV", + "lighting_subspace_type": "sports_arena_playing_area_class_IV", + "ventilation_subspace_type": "sports_entertainment_sports_arena", + "plug_load_subspace_type": "sports arena playing area, class IV" + }, + { + "id": 101, + "space_type": "sports arena - ring sports area", + "lighting_subspace_type": "sports_arena_ring_sports_area", + "ventilation_subspace_type": "sports_entertainment_sports_arena", + "plug_load_subspace_type": null + }, + { + "id": 102, + "space_type": "sports arena - court sports area", + "lighting_subspace_type": "sports_arena_court_sports_area", + "ventilation_subspace_type": "sports_entertainment_sports_arena", + "plug_load_subspace_type": null + }, + { + "id": 103, + "space_type": "sports arena - indoor playing field", + "lighting_subspace_type": "sports_arena_indoor_playing_field", + "ventilation_subspace_type": "sports_entertainment_sports_arena", + "plug_load_subspace_type": null + }, + { + "id": 104, + "space_type": "stairwell", + "lighting_subspace_type": "stairwell", + "ventilation_subspace_type": "general_conference_corridors", + "plug_load_subspace_type": "stairwell" + }, + { + "id": 105, + "space_type": "storage < 50 sf - all other", + "lighting_subspace_type": "storage_ all_other_small", + "ventilation_subspace_type": "general_conference_storage_rooms", + "plug_load_subspace_type": "storage < 50 sf - all other" + }, + { + "id": 106, + "space_type": "storage 50 to 1000 sf - all other", + "lighting_subspace_type": "storage_ all_other_large", + "ventilation_subspace_type": "general_conference_storage_rooms", + "plug_load_subspace_type": "storage 50 to 1000 sf - all other" + }, + { + "id": 107, + "space_type": "storage < 50 sf - hospital", + "lighting_subspace_type": "storage_hospital_small", + "ventilation_subspace_type": "general_conference_storage_rooms", + "plug_load_subspace_type": "storage < 50 sf - hospital" + }, + { + "id": 108, + "space_type": "storage 50 to 1000 sf - hospital", + "lighting_subspace_type": "storage_hospital_large", + "ventilation_subspace_type": "general_conference_storage_rooms", + "plug_load_subspace_type": "storage 50 to 1000 sf - hospital" + }, + { + "id": 109, + "space_type": "storage - inactive", + "lighting_subspace_type": "storage_inactive", + "ventilation_subspace_type": "general_conference_storage_rooms", + "plug_load_subspace_type": "storage - inactive" + }, + { + "id": 110, + "space_type": "storage, inactive - museum", + "lighting_subspace_type": "storage_inactive_museum", + "ventilation_subspace_type": "general_conference_storage_rooms", + "plug_load_subspace_type": null + }, + { + "id": 111, + "space_type": "airport concourse", + "lighting_subspace_type": "airport_concourse", + "ventilation_subspace_type": "office_buildings_reception_areas", + "plug_load_subspace_type": "airport concourse" + }, + { + "id": 112, + "space_type": "baggage/carousel", + "lighting_subspace_type": "baggage_carousel", + "ventilation_subspace_type": "office_buildings_reception_areas", + "plug_load_subspace_type": "baggage/carousel" + }, + { + "id": 113, + "space_type": "transportation ticket counter", + "lighting_subspace_type": "transportation_ticket_counter", + "ventilation_subspace_type": "office_buildings_reception_areas", + "plug_load_subspace_type": "transportation ticket counter" + }, + { + "id": 114, + "space_type": "vehicular maintenance", + "lighting_subspace_type": "vehicular_maintenance", + "ventilation_subspace_type": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", + "plug_load_subspace_type": "vehicular maintenance" + }, + { + "id": 115, + "space_type": "warehouse - bulk storage", + "lighting_subspace_type": "warehouse_bulk_storage", + "ventilation_subspace_type": "miscellaneous_spaces_warehouses", + "plug_load_subspace_type": "warehouse - bulk storage" + }, + { + "id": 116, + "space_type": "warehouse - fine storage", + "lighting_subspace_type": "warehouse_fine_storage", + "ventilation_subspace_type": "miscellaneous_spaces_warehouses", + "plug_load_subspace_type": "warehouse - fine storage" + }, + { + "id": 117, + "space_type": "workshop", + "lighting_subspace_type": "workshop", + "ventilation_subspace_type": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", + "plug_load_subspace_type": "workshop" + }, + { + "id": 118, + "space_type": "sales", + "lighting_subspace_type": "sales", + "ventilation_subspace_type": "retail_sales", + "plug_load_subspace_type": "sales" + }, + { + "id": 119, + "space_type": "sales - display type 1", + "lighting_subspace_type": "sales_display_type_1", + "ventilation_subspace_type": "retail_sales", + "plug_load_subspace_type": null + }, + { + "id": 120, + "space_type": "sales - display type 2", + "lighting_subspace_type": "sales_display_type_2", + "ventilation_subspace_type": "retail_sales", + "plug_load_subspace_type": null + }, + { + "id": 121, + "space_type": "sales - display type 3", + "lighting_subspace_type": "sales_display_type_3", + "ventilation_subspace_type": "retail_sales", + "plug_load_subspace_type": null + }, + { + "id": 122, + "space_type": "sales - display type 4", + "lighting_subspace_type": "sales_display_type_4", + "ventilation_subspace_type": "retail_sales", + "plug_load_subspace_type": null + }, + { + "id": 123, + "space_type": "guest room - highway", + "lighting_subspace_type": "guest_room", + "ventilation_subspace_type": "hotels_motels_resorts_dormitories_barracks_sleeping_areas", + "plug_load_subspace_type": null + }, + { + "id": 124, + "space_type": "lodging dining - highway", + "lighting_subspace_type": "dining_general", + "ventilation_subspace_type": "food_beverage_service_restaurant_dining_rooms", + "plug_load_subspace_type": null + }, + { + "id": 125, + "space_type": "audience seating - classroom/lecture/training", + "lighting_subspace_type": "audience_seating_general", + "ventilation_subspace_type": "public_assembly_spaces_auditorium_seating_area", + "plug_load_subspace_type": null + }, + { + "id": 126, + "space_type": "audience seating - conference/meeting/multipurpose", + "lighting_subspace_type": "audience_seating_general", + "ventilation_subspace_type": "public_assembly_spaces_auditorium_seating_area", + "plug_load_subspace_type": null + }, + { + "id": 127, + "space_type": "audience seating - corridor/transition", + "lighting_subspace_type": "audience_seating_general", + "ventilation_subspace_type": "public_assembly_spaces_auditorium_seating_area", + "plug_load_subspace_type": null + }, + { + "id": 128, + "space_type": "guest room - bathroom", + "lighting_subspace_type": "guest_room", + "ventilation_subspace_type": "hotels_motels_resorts_dormitories_barracks_sleeping_areas", + "plug_load_subspace_type": null + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/initial_data/general_building_space_type_full.csv b/data/openstudio_standards_data/initial_data/general_building_space_type_full.csv new file mode 100644 index 0000000000..38de66d099 --- /dev/null +++ b/data/openstudio_standards_data/initial_data/general_building_space_type_full.csv @@ -0,0 +1,221 @@ +id,building_type,space_type,lighting_space_type_name,ventilation_space_type_name +1,FullServiceRestaurant,Kitchen,kitchen,food_beverage_service_kitchen +2,FullServiceRestaurant,Dining,dining_family,food_beverage_service_restaurant_dining_rooms +3,FullServiceRestaurant,Attic,, +4,HighriseApartment,Apartment,bam_multifamily,hotels_motels_resorts_dormitories_bedroom_living_room +5,HighriseApartment,Apartment_topfloor_NS,bam_multifamily,hotels_motels_resorts_dormitories_bedroom_living_room +6,HighriseApartment,Apartment_topfloor_WE,bam_multifamily,hotels_motels_resorts_dormitories_bedroom_living_room +7,HighriseApartment,Corridor,corridor_general,transient_residential_common_corridors +8,HighriseApartment,Corridor_topfloor,corridor_general,transient_residential_common_corridors +9,HighriseApartment,Office,office_enclosed_small,hotels_motels_resorts_dormitories_multi_purpose_assembly +10,Hospital,Basement,bam_hospital,outpatient_health_care_facilities_general_examination_room +11,Hospital,Corridor,corridor_hospital,general_conference_corridors +12,Hospital,Dining,dining_general,food_beverage_service_restaurant_dining_rooms +13,Hospital,ER_Exam,exam_treatment,outpatient_health_care_facilities_general_examination_room +14,Hospital,ER_NurseStn,nurses_station,outpatient_health_care_facilities_psychiatric_consultation_room +15,Hospital,ER_Trauma,emergency_room,outpatient_health_care_facilities_general_examination_room +16,Hospital,ER_Triage,emergency_room,outpatient_health_care_facilities_general_examination_room +17,Hospital,ICU_NurseStn,nurses_station,outpatient_health_care_facilities_urgent_care_examination_room +18,Hospital,ICU_Open,recovery,outpatient_health_care_facilities_urgent_care_examination_room +19,Hospital,Lab,laboratory_classroom,educational_facilities_science_laboratories +20,Hospital,Lobby,lobby_general,public_assembly_spaces_lobbies +21,Hospital,NurseStn,nurses_station,outpatient_health_care_facilities_psychiatric_consultation_room +22,Hospital,OR,operating_room,outpatient_health_care_facilities_general_examination_room +23,Hospital,PatCorridor,corridor_hospital,general_conference_corridors +24,Hospital,PatRoom,patient_room,outpatient_health_care_facilities_physical_therapy_individual_room +25,Hospital,PhysTherapy,physical_therapy,outpatient_health_care_facilities_physical_therapy_exercise_area +26,Hospital,Radiology,imaging,outpatient_health_care_facilities_class_1_imaging_rooms +27,Hospital,Kitchen,kitchen,food_beverage_service_kitchen +28,Hospital,ICU_PatRm,patient_room,outpatient_health_care_facilities_physical_therapy_individual_room +29,Hospital,Office,office_enclosed_small,office_buildings_office_space +30,Hospital,HospitalOfficeFlr1,office_enclosed_small,office_buildings_office_space +31,Hospital,HospitalOfficeFlr5,office_enclosed_small,office_buildings_office_space +32,LargeHotel,Kitchen,kitchen,food_beverage_service_kitchen +33,LargeHotel,Banquet,dining_hotel,general_conference_meeting +34,LargeHotel,Basement,bam_hotel,hotels_motels_resorts_dormitories_multi_purpose_assembly +35,LargeHotel,Cafe,dining_hotel,food_beverage_service_cafeteria_fast_food_dining +36,LargeHotel,Corridor,corridor_general,general_conference_corridors +37,LargeHotel,Corridor2,corridor_general,general_conference_corridors +38,LargeHotel,GuestRoom,guest_room,hotels_motels_resorts_dormitories_bedroom_living_room +39,LargeHotel,GuestRoom2,guest_room,hotels_motels_resorts_dormitories_bedroom_living_room +40,LargeHotel,GuestRoom3,guest_room,hotels_motels_resorts_dormitories_bedroom_living_room +41,LargeHotel,GuestRoom4,guest_room,hotels_motels_resorts_dormitories_bedroom_living_room +42,LargeHotel,Laundry,laundry_washing,hotels_motels_resorts_dormitories_laundry_rooms +43,LargeHotel,Lobby,lobby_hotel,hotels_motels_resorts_dormitories_lobbies_prefunction +44,LargeHotel,Mechanical,electrical_mechanical,general_conference_corridors +45,LargeHotel,Retail,sales,retail_sales +46,LargeHotel,Retail2,sales,retail_sales +47,LargeHotel,Storage,storage_ all_other_small,office_buildings_occupiable_storage_rooms +48,MidriseApartment,Apartment,bam_multifamily,hotels_motels_resorts_dormitories_bedroom_living_room +49,MidriseApartment,Apartment_topfloor_NS,bam_multifamily,hotels_motels_resorts_dormitories_bedroom_living_room +50,MidriseApartment,Apartment_topfloor_WE,bam_multifamily,hotels_motels_resorts_dormitories_bedroom_living_room +51,MidriseApartment,Corridor,corridor_general,transient_residential_common_corridors +52,MidriseApartment,Corridor_topfloor,corridor_general,transient_residential_common_corridors +53,MidriseApartment,Office,office_enclosed_small,office_buildings_office_space +54,Office,OfficeLarge Data Center,computer_room,miscellaneous_spaces_computer +55,Office,OfficeLarge Main Data Center,computer_room,miscellaneous_spaces_computer +56,Office,WholeBuilding - Sm Office,bam_office,office_buildings_office_space +57,Office,WholeBuilding - Md Office,bam_office,office_buildings_office_space +58,Office,WholeBuilding - Lg Office,bam_office,office_buildings_office_space +59,Office,WholeBuilding - Lg Office-basement,bam_office,office_buildings_office_space +60,Office,Attic,, +61,Office,General,bam_office,office_buildings_office_space +62,Office,Vending,corridor_general,general_conference_corridors +63,Office,Storage,storage_ all_other_small,office_buildings_occupiable_storage_rooms +64,Office,Stair,stairway,general_conference_corridors +65,Office,Restroom,restroom_visually_impaired,general_conference_corridors +66,Office,PrintRoom,office_enclosed_small,general_conference_corridors +67,Office,OpenOffice,office_open,office_buildings_office_space +68,Office,Lobby,lobby_general,public_assembly_spaces_lobbies +69,Office,IT_Room,office_enclosed_small,general_conference_corridors +70,Office,Elec/MechRoom,electrical_mechanical,general_conference_corridors +71,Office,Corridor,corridor_general,general_conference_corridors +72,Office,Conference,conference_meeting_multipurpose,general_conference_meeting +73,Office,ClosedOffice,office_enclosed_small,office_buildings_office_space +74,Office,BreakRoom,lounge_breakroom_general,office_buildings_reception_areas +75,Office,Elevator Lobby,lobby_general,public_assembly_spaces_lobbies +76,Office,Elevator Machine Room,electrical_mechanical,general_conference_corridors +77,Office,Main Electrical,electrical_mechanical,general_conference_corridors +78,Office,Main Mechanical,electrical_mechanical,general_conference_corridors +79,Office,Dining,dining_general,food_beverage_service_cafeteria_fast_food_dining +80,Office,Classroom,classroom_lecture_training_general,educational_facilities_lecture_classroom +81,Office,MediumOffice - Storage,storage_ all_other_small,office_buildings_occupiable_storage_rooms +82,Office,MediumOffice - Stair,stairway,general_conference_corridors +83,Office,MediumOffice - Restroom,restroom_visually_impaired,general_conference_corridors +84,Office,MediumOffice - OpenOffice,office_open,office_buildings_office_space +85,Office,MediumOffice - Lobby,lobby_general,public_assembly_spaces_lobbies +86,Office,MediumOffice - Elec/MechRoom,electrical_mechanical,general_conference_corridors +87,Office,MediumOffice - Corridor,corridor_general,general_conference_corridors +88,Office,MediumOffice - Conference,conference_meeting_multipurpose,general_conference_meeting +89,Office,MediumOffice - ClosedOffice,office_enclosed_small,office_buildings_office_space +90,Office,MediumOffice - Breakroom,lounge_breakroom_general,office_buildings_reception_areas +91,Office,MediumOffice - Dining,dining_general,food_beverage_service_cafeteria_fast_food_dining +92,Office,MediumOffice - Classroom,classroom_lecture_training_general,educational_facilities_lecture_classroom +93,Office,SmallOffice - Attic,, +94,Office,SmallOffice - Storage,storage_ all_other_small,office_buildings_occupiable_storage_rooms +95,Office,SmallOffice - Stair,stairway,general_conference_corridors +96,Office,SmallOffice - Restroom,restroom_visually_impaired,general_conference_corridors +97,Office,SmallOffice - OpenOffice,office_open,office_buildings_office_space +98,Office,SmallOffice - Lobby,lobby_general,public_assembly_spaces_lobbies +99,Office,SmallOffice - Elec/MechRoom,electrical_mechanical,general_conference_corridors +100,Office,SmallOffice - Corridor,corridor_general,general_conference_corridors +101,Office,SmallOffice - Conference,conference_meeting_multipurpose,general_conference_meeting +102,Office,SmallOffice - ClosedOffice,office_enclosed_small,office_buildings_office_space +103,Office,SmallOffice - Breakroom,lounge_breakroom_general,office_buildings_reception_areas +104,Office,SmallOffice - Dining,dining_general,food_beverage_service_cafeteria_fast_food_dining +105,Office,SmallOffice - Classroom,classroom_lecture_training_general,educational_facilities_lecture_classroom +106,Office,WholeBuilding - Lg Office-others,bam_office,office_buildings_office_space +107,Office,WholeBuilding - Lg Office-basement,bam_office,office_buildings_office_space +108,Office,Elevator Shaft,electrical_mechanical,general_conference_corridors +109,Outpatient,Anesthesia,exam_treatment,outpatient_health_care_facilities_general_examination_room +110,Outpatient,BioHazard,storage_hospital_small,office_buildings_occupiable_storage_rooms +111,Outpatient,Cafe,dining_general,food_beverage_service_cafeteria_fast_food_dining +112,Outpatient,CleanWork,exam_treatment,outpatient_health_care_facilities_general_examination_room +113,Outpatient,Conference,conference_meeting_multipurpose,general_conference_meeting +114,Outpatient,DressingRoom,office_enclosed_small,office_buildings_office_space +115,Outpatient,Elec/MechRoom,electrical_mechanical,general_conference_corridors +116,Outpatient,ElevatorPumpRoom,electrical_mechanical,general_conference_corridors +117,Outpatient,Exam,exam_treatment,outpatient_health_care_facilities_general_examination_room +118,Outpatient,Hall,corridor_hospital,general_conference_corridors +119,Outpatient,Hall_infil,corridor_hospital,general_conference_corridors +120,Outpatient,IT_Room,office_enclosed_small,office_buildings_office_space +121,Outpatient,Janitor,storage_hospital_small,office_buildings_occupiable_storage_rooms +122,Outpatient,Lobby,lobby_general,public_assembly_spaces_lobbies +123,Outpatient,LockerRoom,lounge_breakroom_healthcare_facility,public_assembly_spaces_lobbies +124,Outpatient,Lounge,lounge_breakroom_healthcare_facility,public_assembly_spaces_lobbies +125,Outpatient,MedGas,storage_hospital_small,office_buildings_occupiable_storage_rooms +126,Outpatient,MRI,imaging,outpatient_health_care_facilities_class_1_imaging_rooms +127,Outpatient,MRI_Control,imaging,outpatient_health_care_facilities_class_1_imaging_rooms +128,Outpatient,NurseStation,nurses_station,outpatient_health_care_facilities_psychiatric_consultation_room +129,Outpatient,OutpatientFloor2Work,office_enclosed_small,office_buildings_office_space +130,Outpatient,Office,office_enclosed_small,office_buildings_office_space +131,Outpatient,OR,operating_room,outpatient_health_care_facilities_general_examination_room +132,Outpatient,PACU,recovery,outpatient_health_care_facilities_physical_therapy_exercise_area +133,Outpatient,PhysicalTherapy,physical_therapy,outpatient_health_care_facilities_physical_therapy_exercise_area +134,Outpatient,PreOp,patient_room,outpatient_health_care_facilities_physical_therapy_individual_room +135,Outpatient,ProcedureRoom,emergency_room,outpatient_health_care_facilities_general_examination_room +136,Outpatient,Reception,lobby_general,public_assembly_spaces_lobbies +137,Outpatient,Stair,stairway,general_conference_corridors +138,Outpatient,Soil Work,exam_treatment,outpatient_health_care_facilities_general_examination_room +139,Outpatient,Toilet,restroom_visually_impaired,general_conference_corridors +140,Outpatient,Undeveloped,storage_hospital_small,office_buildings_occupiable_storage_rooms +141,Outpatient,Xray,imaging,outpatient_health_care_facilities_class_1_imaging_rooms +142,PrimarySchool,Cafeteria,dining_general,food_beverage_service_cafeteria_fast_food_dining +143,PrimarySchool,Classroom,classroom_lecture_training_general,educational_facilities_classroom_young +144,PrimarySchool,ComputerRoom,classroom_lecture_training_general,educational_facilities_computer_lab +145,PrimarySchool,Corridor,corridor_general,general_conference_corridors +146,PrimarySchool,Gym,gymnasium_exercise_area,sports_entertainment_gym_stadium +147,PrimarySchool,Kitchen,kitchen,food_beverage_service_kitchen +148,PrimarySchool,Library,library_reading,educational_facilities_libraries +149,PrimarySchool,Lobby,lobby_general,public_assembly_spaces_lobbies +150,PrimarySchool,Mechanical,electrical_mechanical,general_conference_corridors +151,PrimarySchool,Office,office_enclosed_small,office_buildings_office_space +152,PrimarySchool,Restroom,restroom_visually_impaired,general_conference_corridors +153,QuickServiceRestaurant,Dining,dining_general,food_beverage_service_cafeteria_fast_food_dining +154,QuickServiceRestaurant,Attic,, +155,QuickServiceRestaurant,Kitchen,kitchen,food_beverage_service_kitchen +156,Retail,Back_Space,storage_ all_other_small,retail_sales +157,Retail,Entry,lobby_general,retail_sales +158,Retail,Point_of_Sale,sales,retail_sales +159,Retail,Retail,sales,retail_sales +160,Retail,Core_Retail,sales,retail_sales +161,Retail,Front_Retail,sales,retail_sales +162,SecondarySchool,Auditorium,audience_seating_general,public_assembly_spaces_auditorium_seating_area +163,SecondarySchool,Cafeteria,dining_general,food_beverage_service_cafeteria_fast_food_dining +164,SecondarySchool,Classroom,classroom_lecture_training_general,educational_facilities_classroom_old +165,SecondarySchool,ComputerRoom,classroom_lecture_training_general,educational_facilities_computer_lab +166,SecondarySchool,Corridor,corridor_general,general_conference_corridors +167,SecondarySchool,Gym,gymnasium_exercise_area,sports_entertainment_gym_stadium +168,SecondarySchool,Library,library_reading,educational_facilities_libraries +169,SecondarySchool,Lobby,lobby_general,public_assembly_spaces_lobbies +170,SecondarySchool,Mechanical,electrical_mechanical,general_conference_corridors +171,SecondarySchool,Office,office_enclosed_small,office_buildings_office_space +172,SecondarySchool,Restroom,restroom_visually_impaired,general_conference_corridors +173,SecondarySchool,Kitchen,kitchen,food_beverage_service_kitchen +174,SmallHotel,GuestRoom,guest_room,hotels_motels_resorts_dormitories_bedroom_living_room +175,SmallHotel,Corridor,corridor_general,general_conference_corridors +176,SmallHotel,Corridor4,corridor_general,general_conference_corridors +177,SmallHotel,Elec/MechRoom,electrical_mechanical,general_conference_corridors +178,SmallHotel,ElevatorCore,lobby_general,general_conference_corridors +179,SmallHotel,ElevatorCore4,lobby_general,general_conference_corridors +180,SmallHotel,Exercise,gymnasium_exercise_area,sports_entertainment_gym_stadium +181,SmallHotel,GuestRoom123Occ,guest_room,hotels_motels_resorts_dormitories_bedroom_living_room +182,SmallHotel,GuestRoom123Vac,guest_room,hotels_motels_resorts_dormitories_bedroom_living_room +183,SmallHotel,GuestRoom4Occ,guest_room,hotels_motels_resorts_dormitories_bedroom_living_room +184,SmallHotel,GuestRoom4Vac,guest_room,hotels_motels_resorts_dormitories_bedroom_living_room +185,SmallHotel,Laundry,laundry_washing,hotels_motels_resorts_dormitories_laundry_rooms +186,SmallHotel,Mechanical,electrical_mechanical,general_conference_corridors +187,SmallHotel,Meeting,conference_meeting_multipurpose,general_conference_meeting +188,SmallHotel,Office,office_enclosed_small,office_buildings_office_space +189,SmallHotel,PublicRestroom,restroom_visually_impaired,general_conference_corridors +190,SmallHotel,StaffLounge,lounge_breakroom_general,general_conference_meeting +191,SmallHotel,Stair,stairway,general_conference_corridors +192,SmallHotel,Stair4,stairway,general_conference_corridors +193,SmallHotel,Storage,storage_ all_other_small,office_buildings_occupiable_storage_rooms +194,SmallHotel,Storage4Front,storage_ all_other_small,office_buildings_occupiable_storage_rooms +195,SmallHotel,Storage4Rear,storage_ all_other_small,office_buildings_occupiable_storage_rooms +196,SmallHotel,GuestLounge,lounge_breakroom_general,public_assembly_spaces_lobbies +197,StripMall,Strip mall - type 0A,sales,retail_sales +198,StripMall,Strip mall - type 0B,sales,retail_sales +199,StripMall,Strip mall - type 1,bam_retail,retail_sales +200,StripMall,Strip mall - type 2,bam_retail,retail_sales +201,StripMall,Strip mall - type 3,bam_retail,retail_sales +202,SuperMarket,Meeting,conference_meeting_multipurpose,general_conference_meeting +203,SuperMarket,Dining,dining_general,food_beverage_service_cafeteria_fast_food_dining +204,SuperMarket,Restroom,restroom_visually_impaired,general_conference_corridors +205,SuperMarket,Elec/MechRoom,electrical_mechanical,general_conference_corridors +206,SuperMarket,Corridor,corridor_general,general_conference_corridors +207,SuperMarket,Deli,sales,retail_supermarket +208,SuperMarket,Bakery,kitchen,retail_supermarket +209,SuperMarket,Vestibule,lobby_general,office_buildings_main_entry_lobbies +210,SuperMarket,Sales,sales,retail_supermarket +211,SuperMarket,Produce,sales,retail_supermarket +212,SuperMarket,DryStorage,storage_ all_other_small,office_buildings_occupiable_storage_rooms +213,SuperMarket,Office,office_enclosed_small,office_buildings_office_space +214,Warehouse,Office,office_enclosed_small,office_buildings_office_space +215,Warehouse,Fine,warehouse_fine_storage,miscellaneous_spaces_warehouses +216,Warehouse,Bulk,warehouse_bulk_storage,miscellaneous_spaces_warehouses +217,LargeHotel,GuestRoom5,guest_room,hotels_motels_resorts_dormitories_bedroom_living_room +218,LargeHotel,GuestRoom6,guest_room,hotels_motels_resorts_dormitories_bedroom_living_room +219,LargeHotel,GuestRoom7,guest_room,hotels_motels_resorts_dormitories_bedroom_living_room +220,LargeHotel,GuestRoom8,guest_room,hotels_motels_resorts_dormitories_bedroom_living_room diff --git a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_boilers_90_1.csv b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_boilers_90_1.csv new file mode 100644 index 0000000000..1580f685cb --- /dev/null +++ b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_boilers_90_1.csv @@ -0,0 +1,22 @@ +id,template,fluid_type,fuel_type,condensing,condensing_control,minimum_capacity,maximum_capacity,start_date,end_date,minimum_annual_fuel_utilization_efficiency,minimum_thermal_efficiency,minimum_combustion_efficiency,efffplr,annotation +1,90.1-2004,Hot Water,Gas,,,0,299999,9/9/1919,9/9/2999,0.8,,,Boiler with No Minimum Turndown,From 90.1-2004 +2,90.1-2004,Hot Water,Gas,,,300000,249999999,9/9/1919,9/9/2999,,0.75,,Boiler with No Minimum Turndown,From 90.1-2004 +3,90.1-2004,Hot Water,Gas,,,250000000,9999999999,9/9/1919,9/9/2999,,,0.8,Boiler with No Minimum Turndown,From 90.1-2004 +4,90.1-2007,Hot Water,Gas,,,0,299999,9/9/1919,9/9/2999,0.8,,,Boiler with No Minimum Turndown,From 90.1-2007 +5,90.1-2007,Hot Water,Gas,,,300000,249999999,9/9/1919,9/9/2999,,0.8,,Boiler with No Minimum Turndown,From 90.1-2007 +6,90.1-2007,Hot Water,Gas,,,250000000,9999999999,9/9/1919,9/9/2999,,,0.82,Boiler with No Minimum Turndown,From 90.1-2007 +7,90.1-2010,Hot Water,Gas,,,0,299999,9/9/1919,9/9/2999,0.8,,,Boiler with No Minimum Turndown,From 90.1-2010 +8,90.1-2010,Hot Water,Gas,,,300000,249999999,9/9/1919,9/9/2999,,0.8,,Boiler with No Minimum Turndown,From 90.1-2010 +9,90.1-2010,Hot Water,Gas,,,250000000,9999999999,9/9/1919,9/9/2999,,,0.82,Boiler with No Minimum Turndown,From 90.1-2010 +10,90.1-2013,Hot Water,Gas,,,0,299999,9/9/1919,9/9/2999,0.82,,,Boiler with No Minimum Turndown,From 90.1-2013 +11,90.1-2013,Hot Water,Gas,,,300000,999999,9/9/1919,9/9/2999,,0.8,,Boiler with No Minimum Turndown,From 90.1-2013 +12,90.1-2013,Hot Water,Gas,,,1000000,249999999,9/9/1919,9/9/2999,,0.8,,Boiler with Minimum Turndown,From 90.1-2013 +13,90.1-2013,Hot Water,Gas,,,250000000,9999999999,9/9/1919,9/9/2999,,,0.82,Boiler with Minimum Turndown,From 90.1-2013 +14,90.1-2016,Hot Water,Gas,,,0,299999,9/9/1919,9/9/2999,0.82,,,Boiler with No Minimum Turndown,From 90.1-2016 +15,90.1-2016,Hot Water,Gas,,,300000,999999,9/9/1919,9/9/2999,,0.8,,Boiler with No Minimum Turndown,From 90.1-2016 +16,90.1-2016,Hot Water,Gas,,,1000000,249999999,9/9/1919,9/9/2999,,0.8,,Boiler with Minimum Turndown,From 90.1-2016 +17,90.1-2016,Hot Water,Gas,,,250000000,9999999999,9/9/1919,9/9/2999,,,0.82,Boiler with Minimum Turndown,From 90.1-2016 +18,90.1-2019,Hot Water,Gas,,,0,299999,9/9/1919,9/9/2999,0.84,,,Boiler with No Minimum Turndown,From 90.1-2019 +19,90.1-2019,Hot Water,Gas,,,300000,999999,9/9/1919,9/9/2999,,0.8,,Boiler with No Minimum Turndown,From 90.1-2019 +20,90.1-2019,Hot Water,Gas,,,1000000,249999999,9/9/1919,9/9/2999,,0.8,,Boiler with Minimum Turndown,From 90.1-2019 +21,90.1-2019,Hot Water,Gas,,,250000000,9999999999,9/9/1919,9/9/2999,,,0.82,Boiler with Minimum Turndown,From 90.1-2019 diff --git a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_chillers_90_1.csv b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_chillers_90_1.csv new file mode 100644 index 0000000000..c904371f30 --- /dev/null +++ b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_chillers_90_1.csv @@ -0,0 +1,163 @@ +template,cooling_type,condenser_type,compressor_type,absorption_type,variable_speed_drive,minimum_capacity,maximum_capacity,start_date,end_date,minimum_full_load_efficiency,minimum_integrated_part_load_value,capft,eirft,eirfplr,annotation +90.1-2004,AirCooled,WithCondenser,,,,0,9999,9/9/1919,9/9/2999,1.256,1.153,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR, +90.1-2004,AirCooled,WithoutCondenser,,,,0,9999,9/9/1919,9/9/2999,1.135,1.019,ChlrAirRecipQRatio_fTchwsToadbSI,ChlrAirRecipEIRRatio_fTchwsToadbSI,ChlrAirRecipEIRRatio_fQRatio, +90.1-2004,AirCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.862,,,,, +90.1-2007,AirCooled,WithCondenser,,,,0,9999,9/9/1919,9/9/2999,1.29,1.164,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Form 90.1-2007 Table 6.8.1A +90.1-2010,AirCooled,WithCondenser,,,,0,149.99,9/9/1919,9/9/2999,1.255,0.941,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR, +90.1-2010,AirCooled,WithCondenser,,,,150,9999,9/9/1919,9/9/2999,1.255,0.941,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR, +90.1-2010,AirCooled,WithoutCondenser,,,,0,9999,9/9/1919,9/9/2999,1.255,0.941,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR, +90.1-2010,AirCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.862,,,,, +90.1-2013,AirCooled,WithCondenser,,,,0,149.99,9/9/1919,12/31/2014,1.25,0.96,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies +90.1-2013,AirCooled,WithCondenser,,,,150,9999,9/9/1919,12/31/2014,1.25,0.94,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies +90.1-2013,AirCooled,WithoutCondenser,,,,0,149.99,9/9/1919,12/31/2014,1.25,0.96,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,AirCooled,WithoutCondenser,,,,150,9999,9/9/1919,12/31/2014,1.25,0.94,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,AirCooled,,,Single Effect,,0,9999,9/9/1919,12/31/2014,5.862,,,,,Path A Efficiencies +90.1-2013,AirCooled,WithCondenser,,,,0,149.99,1/1/2015,12/31/2014,1.188,0.876,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies +90.1-2013,AirCooled,WithCondenser,,,,150,9999,1/1/2015,9/9/2999,1.188,0.857,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies +90.1-2013,AirCooled,WithoutCondenser,,,,0,149.99,1/1/2015,9/9/2999,1.188,0.876,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,AirCooled,WithoutCondenser,,,,150,9999,1/1/2015,9/9/2999,1.188,0.857,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,AirCooled,,,Single Effect,,0,9999,1/1/2015,9/9/2999,5.862,,,,,Path A Efficiencies +90.1-2004,WaterCooled,,Reciprocating,,,0,149.99,9/9/1919,9/9/2999,0.837,0.696,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, +90.1-2004,WaterCooled,,Reciprocating,,,150,9999,9/9/1919,9/9/2999,0.837,0.696,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, +90.1-2004,WaterCooled,,Rotary Screw,,,0,149.99,9/9/1919,9/9/2999,0.79,0.676,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, +90.1-2004,WaterCooled,,Rotary Screw,,,150,299.99,9/9/1919,9/9/2999,0.718,0.628,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, +90.1-2004,WaterCooled,,Rotary Screw,,,300,9999,9/9/1919,9/9/2999,0.639,0.572,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, +90.1-2004,WaterCooled,,Scroll,,,0,149.99,9/9/1919,9/9/2999,0.79,0.676,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, +90.1-2004,WaterCooled,,Scroll,,,150,299.99,9/9/1919,9/9/2999,0.718,0.628,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, +90.1-2004,WaterCooled,,Scroll,,,300,9999,9/9/1919,9/9/2999,0.639,0.572,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, +90.1-2004,WaterCooled,,Centrifugal,,,150,299.99,9/9/1919,9/9/2999,0.634,0.596,WaterCooled_Centrifugal_Chiller_LT150_2004_CAPFT,WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio, +90.1-2004,WaterCooled,,Centrifugal,,,0,149.99,9/9/1919,9/9/2999,0.703,0.67,WaterCooled_Centrifugal_Chiller_LT150_2004_CAPFT,WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio, +90.1-2004,WaterCooled,,Centrifugal,,,300,9999,9/9/1919,9/9/2999,0.577,0.55,WaterCooled_Centrifugal_Chiller_GT150_2004_CAPFT,WaterCooled_Centrifugal_Chiller_GT150_2004_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio, +90.1-2004,WaterCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.024,,,,, +90.1-2007,WaterCooled,,Reciprocating,,,0,74.99,9/9/1919,9/9/2999,0.78,0.63,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Reciprocating,,,75,149.99,9/9/1919,9/9/2999,0.775,0.615,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Reciprocating,,,150,299.99,9/9/1919,9/9/2999,0.68,0.58,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Reciprocating,,,300,9999,9/9/1919,9/9/2999,0.62,0.54,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Scroll,,,0,74.99,9/9/1919,9/9/2999,0.78,0.63,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Scroll,,,75,149.99,9/9/1919,9/9/2999,0.775,0.615,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Scroll,,,150,299.99,9/9/1919,9/9/2999,0.68,0.58,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Scroll,,,300,9999,9/9/1919,9/9/2999,0.62,0.54,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Rotary Screw,,,0,74.99,9/9/1919,9/9/2999,0.78,0.63,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Rotary Screw,,,75,149.99,9/9/1919,9/9/2999,0.775,0.615,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Rotary Screw,,,150,299.99,9/9/1919,9/9/2999,0.68,0.58,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Rotary Screw,,,300,9999,9/9/1919,9/9/2999,0.62,0.54,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Centrifugal,,,0,149.99,9/9/1919,9/9/2999,0.634,0.596,WaterCooled_Centrifugal_Chiller_LT150_2004_CAPFT,WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Centrifugal,,,150,299.99,9/9/1919,9/9/2999,0.634,0.596,WaterCooled_Centrifugal_Chiller_LT150_2004_CAPFT,WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Centrifugal,,,300,599.99,9/9/1919,9/9/2999,0.576,0.549,WaterCooled_Centrifugal_Chiller_GT150_2004_CAPFT,WaterCooled_Centrifugal_Chiller_GT150_2004_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Centrifugal,,,600,9999,9/9/1919,9/9/2999,0.57,0.539,WaterCooled_Centrifugal_Chiller_GT150_2004_CAPFT,WaterCooled_Centrifugal_Chiller_GT150_2004_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Reciprocating,,,0,74.99,9/9/1919,9/9/2999,0.78,0.63,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Reciprocating,,,75,149.99,9/9/1919,9/9/2999,0.775,0.615,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Reciprocating,,,150,299.99,9/9/1919,9/9/2999,0.68,0.58,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Reciprocating,,,300,9999,9/9/1919,9/9/2999,0.62,0.54,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Scroll,,,0,74.99,9/9/1919,9/9/2999,0.78,0.63,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Scroll,,,75,149.99,9/9/1919,9/9/2999,0.775,0.615,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Scroll,,,150,299.99,9/9/1919,9/9/2999,0.68,0.58,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Scroll,,,300,9999,9/9/1919,9/9/2999,0.62,0.54,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Rotary Screw,,,0,74.99,9/9/1919,9/9/2999,0.78,0.63,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Rotary Screw,,,75,149.99,9/9/1919,9/9/2999,0.775,0.615,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Rotary Screw,,,150,299.99,9/9/1919,9/9/2999,0.68,0.58,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Rotary Screw,,,300,9999,9/9/1919,9/9/2999,0.62,0.54,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Centrifugal,,,0,149.99,9/9/1919,9/9/2999,0.634,0.596,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Centrifugal,,,150,299.99,9/9/1919,9/9/2999,0.634,0.596,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Centrifugal,,,300,599.99,9/9/1919,9/9/2999,0.576,0.549,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Centrifugal,,,600,9999,9/9/1919,9/9/2999,0.57,0.539,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.024,,,,, +90.1-2013,WaterCooled,,Reciprocating,,,0,74.99,9/9/1919,12/31/2014,0.78,0.63,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Reciprocating,,,75,149.99,9/9/1919,12/31/2014,0.775,0.615,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Reciprocating,,,150,299.99,9/9/1919,12/31/2014,0.68,0.58,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Reciprocating,,,300,599.99,9/9/1919,12/31/2014,0.62,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Reciprocating,,,600,9999,9/9/1919,12/31/2014,0.62,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Scroll,,,0,74.99,9/9/1919,12/31/2014,0.78,0.63,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Scroll,,,75,149.99,9/9/1919,12/31/2014,0.775,0.615,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Scroll,,,150,299.99,9/9/1919,12/31/2014,0.68,0.58,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Scroll,,,300,599.99,9/9/1919,12/31/2014,0.62,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Scroll,,,600,9999,9/9/1919,12/31/2014,0.62,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Rotary Screw,,,0,74.99,9/9/1919,12/31/2014,0.78,0.63,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Rotary Screw,,,75,149.99,9/9/1919,12/31/2014,0.775,0.615,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Rotary Screw,,,150,299.99,9/9/1919,12/31/2014,0.68,0.58,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Rotary Screw,,,300,599.99,9/9/1919,12/31/2014,0.62,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Rotary Screw,,,600,9999,9/9/1919,12/31/2014,0.62,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Centrifugal,,,0,149.99,9/9/1919,12/31/2014,0.634,0.596,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Centrifugal,,,150,399.99,9/9/1919,12/31/2014,0.634,0.596,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Centrifugal,,,400,599.99,9/9/1919,12/31/2014,0.576,0.549,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Centrifugal,,,600,9999,9/9/1919,12/31/2014,0.57,0.539,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Add but unsure what to put for Minimum full load efficiency and min IPLV +90.1-2013,WaterCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.024,,,,,Path A Efficiencies +90.1-2013,WaterCooled,,Reciprocating,,,0,74.99,1/1/2015,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Reciprocating,,,75,149.99,1/1/2015,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Reciprocating,,,150,299.99,1/1/2015,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Reciprocating,,,300,599.99,1/1/2015,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Reciprocating,,,600,9999,1/1/2015,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Scroll,,,0,74.99,1/1/2015,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Scroll,,,75,149.99,1/1/2015,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Scroll,,,150,299.99,1/1/2015,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Scroll,,,300,599.99,1/1/2015,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Scroll,,,600,9999,1/1/2015,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Rotary Screw,,,0,74.99,1/1/2015,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Rotary Screw,,,75,149.99,1/1/2015,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Rotary Screw,,,150,299.99,1/1/2015,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Rotary Screw,,,300,599.99,1/1/2015,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Rotary Screw,,,600,9999,1/1/2015,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Centrifugal,,,0,149.99,1/1/2015,9/9/2999,0.61,0.55,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Centrifugal,,,150,399.99,1/1/2015,9/9/2999,0.56,0.52,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Centrifugal,,,400,599.99,1/1/2015,9/9/2999,0.56,0.5,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Centrifugal,,,600,9999,1/1/2015,9/9/2999,0.56,0.5,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Add but unsure what to put for Minimum full load efficiency and min IPLV +90.1-2004,,,,Double Effect Indirect Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.35,,,, +90.1-2004,,,,Double Effect Direct Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.517,,,, +90.1-2010,,,,Double Effect Indirect Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.35,,,, +90.1-2010,,,,Double Effect Direct Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.517,,,, +90.1-2013,,,,Double Effect Indirect Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.35,,,,Path A Efficiencies +90.1-2013,,,,Double Effect Direct Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.517,,,,Path A Efficiencies +90.1-2016,AirCooled,WithCondenser,,,,0,149.99,9/9/1919,9/9/2999,1.188,0.876,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies +90.1-2016,AirCooled,WithCondenser,,,,150,9999,9/9/1919,9/9/2999,1.188,0.857,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies +90.1-2016,AirCooled,WithoutCondenser,,,,0,149.99,9/9/1919,9/9/2999,1.188,0.876,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,AirCooled,WithoutCondenser,,,,150,9999,9/9/1919,9/9/2999,1.188,0.857,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,AirCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.862,,,,,Path A Efficiencies +90.1-2016,WaterCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.024,,,,,Path A Efficiencies +90.1-2016,WaterCooled,,Reciprocating,,,0,74.99,9/9/1919,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Reciprocating,,,75,149.99,9/9/1919,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Reciprocating,,,150,299.99,9/9/1919,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Reciprocating,,,300,599.99,9/9/1919,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Reciprocating,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Scroll,,,0,74.99,9/9/1919,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Scroll,,,75,149.99,9/9/1919,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Scroll,,,150,299.99,9/9/1919,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Scroll,,,300,599.99,9/9/1919,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Scroll,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Rotary Screw,,,0,74.99,9/9/1919,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Rotary Screw,,,75,149.99,9/9/1919,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Rotary Screw,,,150,299.99,9/9/1919,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Rotary Screw,,,300,599.99,9/9/1919,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Rotary Screw,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Centrifugal,,,0,149.99,9/9/1919,9/9/2999,0.61,0.55,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Centrifugal,,,150,399.99,9/9/1919,9/9/2999,0.56,0.52,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Centrifugal,,,400,599.99,9/9/1919,9/9/2999,0.56,0.5,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Centrifugal,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,,,,Double Effect Indirect Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.35,,,,Path A Efficiencies +90.1-2016,,,,Double Effect Direct Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.517,,,,Path A Efficiencies +90.1-2019,AirCooled,WithCondenser,,,,0,149.99,9/9/1919,9/9/2999,1.188,0.876,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies +90.1-2019,AirCooled,WithCondenser,,,,150,9999,9/9/1919,9/9/2999,1.188,0.857,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies +90.1-2019,AirCooled,WithoutCondenser,,,,0,149.99,9/9/1919,9/9/2999,1.188,0.876,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,AirCooled,WithoutCondenser,,,,150,9999,9/9/1919,9/9/2999,1.188,0.857,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,AirCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.862,,,,,Path A Efficiencies +90.1-2019,WaterCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.024,,,,,Path A Efficiencies +90.1-2019,WaterCooled,,Reciprocating,,,0,74.99,9/9/1919,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Reciprocating,,,75,149.99,9/9/1919,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Reciprocating,,,150,299.99,9/9/1919,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Reciprocating,,,300,599.99,9/9/1919,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Reciprocating,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Scroll,,,0,74.99,9/9/1919,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Scroll,,,75,149.99,9/9/1919,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Scroll,,,150,299.99,9/9/1919,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Scroll,,,300,599.99,9/9/1919,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Scroll,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Rotary Screw,,,0,74.99,9/9/1919,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Rotary Screw,,,75,149.99,9/9/1919,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Rotary Screw,,,150,299.99,9/9/1919,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Rotary Screw,,,300,599.99,9/9/1919,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Rotary Screw,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Centrifugal,,,0,149.99,9/9/1919,9/9/2999,0.61,0.55,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Centrifugal,,,150,399.99,9/9/1919,9/9/2999,0.56,0.52,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Centrifugal,,,400,599.99,9/9/1919,9/9/2999,0.56,0.5,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Centrifugal,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,,,,Double Effect Indirect Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.35,,,,Path A Efficiencies +90.1-2019,,,,Double Effect Direct Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.517,,,,Path A Efficiencies diff --git a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_furnaces_90_1.csv b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_furnaces_90_1.csv new file mode 100644 index 0000000000..7bbcdb7238 --- /dev/null +++ b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_furnaces_90_1.csv @@ -0,0 +1,13 @@ +template,minimum_capacity,maximum_capacity,start_date,end_date,minimum_annual_fuel_utilization_efficiency,minimum_thermal_efficiency,minimum_combustion_efficiency,annotation +90.1-2004,0,224999,9/9/1919,9/9/2999,0.78,0.8,,Table 6.8.1E page 49 +90.1-2004,225000,249999999,9/9/1919,9/9/2999,,,0.8,Table 6.8.1E page 49 +90.1-2007,0,224999,9/9/1919,9/9/2999,0.78,0.8,,Table 6.8.1E page 49 +90.1-2007,225000,249999999,9/9/1919,9/9/2999,,,0.8,Table 6.8.1E page 49 +90.1-2010,0,224999,9/9/1919,9/9/2999,0.78,0.8,,Table 6.8.1E page 62 +90.1-2010,225000,249999999,9/9/1919,9/9/2999,,0.8,,Table 6.8.1E page 62 +90.1-2013,0,224999,9/9/1919,9/9/2999,0.78,0.8,,Table 6.8.1E page 72 +90.1-2013,225000,249999999,9/9/1919,9/9/2999,,0.8,,Table 6.8.1E page 72 +90.1-2016,0,224999,9/9/1919,9/9/2999,0.78,0.8,,Table 6.8.1E page 116 +90.1-2016,225000,249999999,9/9/1919,9/9/2999,,0.8,,Table 6.8.1E page 116 +90.1-2019,0,224999,9/9/1919,9/9/2999,,0.81,,Table 6.8.1-6 for > 225 ktbu/hr; Table F-4 for < 225 ktbu/hr +90.1-2019,225000,249999999,9/9/1919,9/9/2999,,0.8,,Table 6.8.1-6 for > 225 ktbu/hr; Table F-4 for < 225 ktbu/hr diff --git a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_heat_pump_cooling_90_1.csv b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_heat_pump_cooling_90_1.csv new file mode 100644 index 0000000000..3ea90977be --- /dev/null +++ b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_heat_pump_cooling_90_1.csv @@ -0,0 +1,165 @@ +template,cooling_type,heating_type,subcategory,minimum_capacity,maximum_capacity,start_date,end_date,minimum_seasonal_efficiency,minimum_full_load_efficiency,minimum_iplv,minimum_integrated_energy_efficiency_ratio,pthp_eer_coefficient_1,pthp_eer_coefficient_2,cool_cap_ft,cool_cap_fflow,cool_eir_ft,cool_eir_fflow,cool_plf_fplr,annotation +90.1-2004,AirCooled,Electric Resistance or None,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,12.3,0.213,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1D +90.1-2004,AirCooled,All Other,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,12.3,0.213,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1D +90.1-2007,AirCooled,Electric Resistance or None,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,12.3,0.213,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2007 Table 6.8.1D +90.1-2007,AirCooled,All Other,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,12.3,0.213,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2007 Table 6.8.1D +90.1-2010,AirCooled,Electric Resistance or None,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,12.3,0.213,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1D Before 10/8/2012 +90.1-2010,AirCooled,All Other,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,12.3,0.213,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1D Before 10/8/2012 +90.1-2013,AirCooled,Electric Resistance or None,PTHP,0,9999999,9/9/1919,12/31/2015,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2013 Table 6.8.1-4 +90.1-2013,AirCooled,All Other,PTHP,0,9999999,9/9/1919,12/31/2015,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2013 Table 6.8.1-4 +90.1-2013,AirCooled,Electric Resistance or None,PTHP,0,9999999,1/1/2016,9/9/2999,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2013 Table 6.8.1-4 +90.1-2013,AirCooled,All Other,PTHP,0,9999999,1/1/2016,9/9/2999,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2013 Table 6.8.1-4 +90.1-2004,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,9.7,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2004,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,9.7,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2004,ThroughWall,Electric Resistance or None,Single Package,0,29999,9/9/1919,9/9/2999,9.7,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2004,ThroughWall,All Other,Single Package,0,29999,9/9/1919,9/9/2999,9.7,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2004,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B +90.1-2004,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,9.9,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B +90.1-2004,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,9.3,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B +90.1-2004,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,9.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B +90.1-2004,AirCooled,Electric Resistance or None,Single Package,240000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B +90.1-2004,AirCooled,All Other,Single Package,240000,9999999,9/9/1919,9/9/2999,,8.8,9,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B +90.1-2007,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" +90.1-2007,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" +90.1-2007,ThroughWall,Electric Resistance or None,Single Package,0,29999,9/9/1919,9/9/2999,10.6,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" +90.1-2007,ThroughWall,All Other,Single Package,0,29999,9/9/1919,9/9/2999,10.6,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" +90.1-2007,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" +90.1-2007,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,9.9,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" +90.1-2007,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,9.3,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" +90.1-2007,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,9.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" +90.1-2007,AirCooled,Electric Resistance or None,Single Package,240000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" +90.1-2007,AirCooled,All Other,Single Package,240000,9999999,9/9/1919,9/9/2999,,8.8,9,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" +90.1-2010,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,ThroughWall,Electric Resistance or None,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,ThroughWall,All Other,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,11,,11.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,10.8,,11,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,10.6,,10.7,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,10.4,,10.5,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,Electric Resistance or None,Single Package,240000,9999999,9/9/1919,9/9/2999,,9.5,,9.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,All Other,Single Package,240000,9999999,9/9/1919,9/9/2999,,9.3,,9.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2013,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,12/31/2014,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 +90.1-2013,AirCooled,All Other,Single Package,0,64999,9/9/1919,12/31/2014,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 +90.1-2013,AirCooled,Electric Resistance or None,Single Package,0,64999,1/1/2015,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 +90.1-2013,AirCooled,All Other,Single Package,0,64999,1/1/2015,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 +90.1-2013,ThroughWall,Electric Resistance or None,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 +90.1-2013,ThroughWall,All Other,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 +90.1-2013,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,12/31/2015,,11,,11.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,Electric Resistance or None,Single Package,65000,134999,1/1/2016,9/9/2999,,11,,12.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,All Other,Single Package,65000,134999,9/9/1919,12/31/2015,,10.8,,11,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,All Other,Single Package,65000,134999,1/1/2016,9/9/2999,,10.8,,12,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,12/31/2015,,10.6,,10.7,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,Electric Resistance or None,Single Package,135000,239999,1/1/2016,9/9/2999,,10.6,,11.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,All Other,Single Package,135000,239999,9/9/1919,12/31/2015,,10.4,,10.5,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,All Other,Single Package,135000,239999,1/1/2016,9/9/2999,,10.4,,11.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,Electric Resistance or None,Single Package,240000,9999999,9/9/1919,12/31/2015,,9.5,,9.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,Electric Resistance or None,Single Package,240000,9999999,1/1/2016,9/9/2999,,9.5,,10.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,All Other,Single Package,240000,9999999,9/9/1919,12/31/2015,,9.3,,9.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,All Other,Single Package,240000,9999999,1/1/2016,9/9/2999,,9.3,,0.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2004,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,10,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2004,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,10,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2004,ThroughWall,Electric Resistance or None,Split System,0,29999,9/9/1919,9/9/2999,10,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2004,ThroughWall,All Other,Split System,0,29999,9/9/1919,9/9/2999,10,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2004,SmallDuctHighVelocity,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,10,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B +90.1-2004,SmallDuctHighVelocity,All Other,Split System,0,64999,9/9/1919,9/9/2999,10,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B +90.1-2004,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B +90.1-2004,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,9.9,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B +90.1-2004,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,9.3,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B +90.1-2004,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,9.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B +90.1-2004,AirCooled,Electric Resistance or None,Split System,240000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B +90.1-2004,AirCooled,All Other,Split System,240000,9999999,9/9/1919,9/9/2999,,8.8,9,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B +90.1-2007,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" +90.1-2007,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" +90.1-2007,ThroughWall,Electric Resistance or None,Split System,0,29999,9/9/1919,9/9/2999,10.9,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" +90.1-2007,ThroughWall,All Other,Split System,0,29999,9/9/1919,9/9/2999,10.9,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" +90.1-2007,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" +90.1-2007,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,9.9,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" +90.1-2007,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,9.3,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" +90.1-2007,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,9.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" +90.1-2007,AirCooled,Electric Resistance or None,Split System,240000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" +90.1-2007,AirCooled,All Other,Split System,240000,9999999,9/9/1919,9/9/2999,,8.8,9,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" +90.1-2010,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,ThroughWall,Electric Resistance or None,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,ThroughWall,All Other,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,11,,11.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,10.8,,11,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,10.6,,10.7,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,10.4,,10.5,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,Electric Resistance or None,Split System,240000,9999999,9/9/1919,9/9/2999,,9.5,,9.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,All Other,Split System,240000,9999999,9/9/1919,9/9/2999,,9.3,,9.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2013,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,12/31/2014,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 +90.1-2013,AirCooled,All Other,Split System,0,64999,9/9/1919,12/31/2014,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 +90.1-2013,AirCooled,Electric Resistance or None,Split System,0,64999,1/1/2015,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 +90.1-2013,AirCooled,All Other,Split System,0,64999,1/1/2015,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 +90.1-2013,ThroughWall,Electric Resistance or None,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 +90.1-2013,ThroughWall,All Other,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 +90.1-2013,SmallDuctHighVelocity,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,11,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,SmallDuctHighVelocity,All Other,Split System,0,64999,9/9/1919,9/9/2999,11,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,12/31/2015,,11,,11.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,Electric Resistance or None,Split System,65000,134999,1/1/2016,9/9/2999,,11,,12.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,All Other,Split System,65000,134999,9/9/1919,12/31/2015,,10.8,,11,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,All Other,Split System,65000,134999,1/1/2016,9/9/2999,,10.8,,12,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,12/31/2015,,10.6,,10.7,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,Electric Resistance or None,Split System,135000,239999,1/1/2016,9/9/2999,,10.6,,11.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,All Other,Split System,135000,239999,9/9/1919,12/31/2015,,10.4,,10.5,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,All Other,Split System,135000,239999,1/1/2016,9/9/2999,,10.4,,11.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,Electric Resistance or None,Split System,240000,9999999,9/9/1919,12/31/2015,,9.5,,9.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,Electric Resistance or None,Split System,240000,9999999,1/1/2016,9/9/2999,,9.5,,10.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,All Other,Split System,240000,9999999,9/9/1919,12/31/2015,,9.3,,9.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,All Other,Split System,240000,9999999,1/1/2016,9/9/2999,,9.3,,0.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2016,AirCooled,Electric Resistance or None,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,All Other,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,ThroughWall,Electric Resistance or None,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,ThroughWall,All Other,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,11,,12.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,10.8,,12,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,10.6,,11.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,10.4,,11.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,Electric Resistance or None,Single Package,240000,9999999,9/9/1919,9/9/2999,,9.5,,10.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,All Other,Single Package,240000,9999999,9/9/1919,9/9/2999,,9.3,,0.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,ThroughWall,Electric Resistance or None,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,ThroughWall,All Other,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,SmallDuctHighVelocity,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,11,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,SmallDuctHighVelocity,All Other,Split System,0,64999,9/9/1919,9/9/2999,11,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,11,,12.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,10.8,,12,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,10.6,,11.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,10.4,,11.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,Electric Resistance or None,Split System,240000,9999999,9/9/1919,9/9/2999,,9.5,,10.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,All Other,Split System,240000,9999999,9/9/1919,9/9/2999,,9.3,,0.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,PTHP,0,6999,9/9/1919,9/9/2999,,11.9,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,PTHP,0,6999,9/9/1919,9/9/2999,,11.9,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,PTHP,7000,14999,1/1/2016,9/9/2999,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,PTHP,7000,14999,1/1/2016,9/9/2999,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,PTHP,15000,9999999,9/9/1919,9/9/2999,,9.5,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,PTHP,15000,9999999,9/9/1919,9/9/2999,,9.5,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,12/31/2014,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,Single Package,0,64999,9/9/1919,12/31/2014,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,ThroughWall,Electric Resistance or None,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,ThroughWall,All Other,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,11,,12.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,10.8,,12,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,10.6,,11.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,10.4,,11.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,Single Package,240000,9999999,9/9/1919,9/9/2999,,9.5,,10.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,Single Package,240000,9999999,9/9/1919,9/9/2999,,9.3,,0.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,ThroughWall,Electric Resistance or None,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,ThroughWall,All Other,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,SmallDuctHighVelocity,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,11,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,SmallDuctHighVelocity,All Other,Split System,0,64999,9/9/1919,9/9/2999,11,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,11,,12.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,10.8,,12,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,10.6,,11.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,10.4,,11.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,Split System,240000,9999999,9/9/1919,9/9/2999,,9.5,,10.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,Split System,240000,9999999,9/9/1919,9/9/2999,,9.3,,0.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, diff --git a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_heat_pump_heating_90_1.csv b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_heat_pump_heating_90_1.csv new file mode 100644 index 0000000000..b5fe02a2c7 --- /dev/null +++ b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_heat_pump_heating_90_1.csv @@ -0,0 +1,51 @@ +template,cooling_type,subcategory,minimum_capacity,maximum_capacity,start_date,end_date,minimum_heating_seasonal_performance_factor,minimum_coefficient_of_performance_heating,minimum_energy_efficiency_ratio,pthp_cop_coefficient_1,pthp_cop_coefficient_2,heat_cap_ft,heat_cap_fflow,heat_eir_ft,heat_eir_fflow,heat_plf_fplr,annotation +90.1-2004,AirCooled,PTHP,0,9999999,9/9/1919,9/9/2999,,,,3.2,0.026,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2004 Table 6.8.1D +90.1-2007,AirCooled,PTHP,0,9999999,9/9/1919,9/9/2999,,,,3.2,0.026,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2007 Table 6.8.1D +90.1-2010,AirCooled,PTHP,0,9999999,9/9/1919,9/9/2999,,,,3.2,0.026,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2010 Table 6.8.1D before 10/08/2012 +90.1-2013,AirCooled,PTHP,0,9999999,9/9/1919,9/9/2999,,,,3.7,0.052,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2013 Table 6.8.1-4 +90.1-2004,AirCooled,Single Package,0,64999,9/9/1919,9/9/2999,6.6,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2004,ThroughWall,Single Package,0,29999,9/9/1919,9/9/2999,6.6,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2004,AirCooled,Single Package,65000,134999,9/9/1919,9/9/2999,,3.2,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2004,AirCooled,Single Package,135000,9999999,9/9/1919,9/9/2999,,3.1,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2007,AirCooled,Single Package,0,64999,9/9/1919,9/9/2999,7.7,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" +90.1-2007,ThroughWall,Single Package,0,29999,9/9/1919,9/9/2999,7,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" +90.1-2007,AirCooled,Single Package,65000,134999,9/9/1919,9/9/2999,,3.2,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" +90.1-2007,AirCooled,Single Package,135000,9999999,9/9/1919,9/9/2999,,3.1,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" +90.1-2010,AirCooled,Single Package,0,64999,9/9/1919,9/9/2999,7.7,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,ThroughWall,Single Package,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,Single Package,65000,134999,9/9/1919,9/9/2999,,3.3,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,Single Package,135000,9999999,9/9/1919,9/9/2999,,3.2,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2013,AirCooled,Single Package,0,64999,9/9/1919,12/31/2014,7.7,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2013 Table 6.8.1-2, Before 1/1/2015" +90.1-2013,AirCooled,Single Package,0,64999,1/1/2015,9/9/2999,8,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2013 Table 6.8.1-2, Before 1/1/2015" +90.1-2013,ThroughWall,Single Package,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2013 Table 6.8.1-3 +90.1-2013,AirCooled,Single Package,65000,134999,9/9/1919,9/9/2999,,3.3,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR,From 90.1-2013 Table 6.8.1-5 +90.1-2013,AirCooled,Single Package,135000,9999999,9/9/1919,9/9/2999,,3.2,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR,From 90.1-2013 Table 6.8.1-6 +90.1-2004,AirCooled,Split System,0,64999,9/9/1919,9/9/2999,6.8,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2004,ThroughWall,Split System,0,29999,9/9/1919,9/9/2999,6.8,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2004,SmallDuctHighVelocity,Split System,0,64999,9/9/1919,9/9/2999,6.8,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2007,AirCooled,Split System,0,64999,9/9/1919,9/9/2999,7.7,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" +90.1-2007,ThroughWall,Split System,0,29999,9/9/1919,9/9/2999,7.1,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" +90.1-2010,AirCooled,Split System,0,64999,9/9/1919,9/9/2999,7.7,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,ThroughWall,Split System,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2013,AirCooled,Split System,0,64999,9/9/1919,12/31/2014,7.7,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2013 Table 6.8.1-2, Before 1/1/2015" +90.1-2013,AirCooled,Split System,0,64999,1/1/2015,9/9/2999,8.2,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2013 Table 6.8.1-2, Before 1/1/2015" +90.1-2013,ThroughWall,Split System,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2013 Table 6.8.1-2 +90.1-2013,SmallDuctHighVelocity,Split System,0,64999,9/9/1919,9/9/2999,6.8,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2013 Table 6.8.1-4 +90.1-2016,AirCooled,PTHP,0,9999999,9/9/1919,9/9/2999,,,,3.7,0.052,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, +90.1-2016,AirCooled,Single Package,0,64999,9/9/1919,9/9/2999,8,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,ThroughWall,Single Package,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, +90.1-2016,AirCooled,Single Package,65000,134999,9/9/1919,9/9/2999,,3.3,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,Single Package,135000,9999999,9/9/1919,9/9/2999,,3.2,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,Split System,0,64999,9/9/1919,9/9/2999,8.2,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,ThroughWall,Split System,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, +90.1-2016,SmallDuctHighVelocity,Split System,0,64999,9/9/1919,9/9/2999,6.8,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, +90.1-2019,AirCooled,PTHP,0,6999,9/9/1919,9/9/2999,,3.3,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, +90.1-2019,AirCooled,PTHP,6999,14999,9/9/1919,9/9/2999,,,,3.7,0.052,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, +90.1-2019,AirCooled,PTHP,14999,9999999,9/9/1919,9/9/2999,,2.9,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, +90.1-2019,AirCooled,Single Package,0,64999,9/9/1919,9/9/2999,8,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,ThroughWall,Single Package,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, +90.1-2019,AirCooled,Single Package,65000,134999,9/9/1919,9/9/2999,,3.3,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Single Package,135000,9999999,9/9/1919,9/9/2999,,3.2,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Split System,0,64999,9/9/1919,9/9/2999,8.2,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,ThroughWall,Split System,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, +90.1-2019,SmallDuctHighVelocity,Split System,0,64999,9/9/1919,9/9/2999,6.8,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, diff --git a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_heat_rejection_90_1.csv b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_heat_rejection_90_1.csv new file mode 100644 index 0000000000..886007d819 --- /dev/null +++ b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_heat_rejection_90_1.csv @@ -0,0 +1,31 @@ +template,equipment_type,fan_type,start_date,end_date,minimum_performance_gpm_per_hp,annotation +90.1-2004,Open Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2004 Table 6.8.1G +90.1-2004,Open Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,38.2,From 90.1-2004 Table 6.8.1G +90.1-2004,Closed Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2004 Table 6.8.1G +90.1-2004,Closed Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,38.2,From 90.1-2004 Table 6.8.1G +90.1-2004,Dry Cooler,Propeller or Axial,9/9/1919,9/9/2999,4,Not required by code. Value provided by 90.1 Mechanical Subcommittee +90.1-2007,Open Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2007 Table 6.8.1G +90.1-2007,Open Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,38.2,From 90.1-2007 Table 6.8.1G +90.1-2007,Closed Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2007 Table 6.8.1G +90.1-2007,Closed Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,38.2,From 90.1-2007 Table 6.8.1G +90.1-2007,Dry Cooler,Propeller or Axial,9/9/1919,9/9/2999,4,Not required by code. Value provided by 90.1 Mechanical Subcommittee +90.1-2010,Open Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2010 Table 6.8.1 G +90.1-2010,Open Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,38.2,From 90.1-2010 Table 6.8.1 G +90.1-2010,Closed Cooling Tower,Centrifugal,9/9/1919,9/9/2999,7,From 90.1-2010 Table 6.8.1 G +90.1-2010,Closed Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,14,From 90.1-2010 Table 6.8.1 G +90.1-2010,Dry Cooler,Propeller or Axial,9/9/1919,9/9/2999,4,Not required by code. Value provided by 90.1 Mechanical Subcommittee +90.1-2013,Open Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2013 Table 6.8.1-7 +90.1-2013,Open Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,40.2,From 90.1-2013 Table 6.8.1-7 +90.1-2013,Closed Cooling Tower,Centrifugal,9/9/1919,9/9/2999,7,From 90.1-2013 Table 6.8.1-7 +90.1-2013,Closed Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,14,From 90.1-2013 Table 6.8.1-7 +90.1-2013,Dry Cooler,Propeller or Axial,9/9/1919,9/9/2999,4,NOTE: Not required by code. Value provided by 90.1 Mechanical Subcommittee +90.1-2016,Open Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2016 Table 6.8.1-7 +90.1-2016,Open Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,40.2,From 90.1-2016 Table 6.8.1-7 +90.1-2016,Closed Cooling Tower,Centrifugal,9/9/1919,9/9/2999,7,From 90.1-2016 Table 6.8.1-7 +90.1-2016,Closed Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,16.1,From 90.1-2016 Table 6.8.1-7 +90.1-2016,Dry Cooler,Propeller or Axial,9/9/1919,9/9/2999,4,NOTE Not required by code. Value provided by 90.1 Mechanical Subcommittee +90.1-2019,Open Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2019 Table 6.8.1-7 +90.1-2019,Open Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,40.2,From 90.1-2019 Table 6.8.1-7 +90.1-2019,Closed Cooling Tower,Centrifugal,9/9/1919,9/9/2999,7,From 90.1-2019 Table 6.8.1-7 +90.1-2019,Closed Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,16.1,From 90.1-2019 Table 6.8.1-7 +90.1-2019,Dry Cooler,Propeller or Axial,9/9/1919,9/9/2999,4.5,From 90.1-2019 Table 6.8.1.7. Juan Gonzalez Added 01/11/2021 to account for fluid coolers in data center water loop heat pump condenser loops diff --git a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_motors_90_1.csv b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_motors_90_1.csv new file mode 100644 index 0000000000..986abcdab9 --- /dev/null +++ b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_motors_90_1.csv @@ -0,0 +1,148 @@ +template,number_of_poles,type,synchronous_speed,minimum_capacity,maximum_capacity,nominal_full_load_efficiency,annotation +90.1-2004,4,Enclosed,1800,0,0.999,0.29,"Motors below 1 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" +90.1-2004,4,Enclosed,1800,1,1.499,0.825,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,1.5,1.999,0.84,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,2,2.999,0.84,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,3,4.999,0.875,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,5,7.499,0.875,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,7.5,9.999,0.895,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,10,14.999,0.895,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,15,19.999,0.91,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,20,24.999,0.91,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,25,29.999,0.924,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,30,39.999,0.924,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,40,49.999,0.93,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,50,59.999,0.93,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,60,74.999,0.936,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,75,99.999,0.941,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,100,124.999,0.945,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,125,149.999,0.945,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,150,199.999,0.95,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,200,9999,0.95,From 90.1-2004 Table 10.8 +90.1-2007,4,Enclosed,1800,0,0.999,0.29,"Motors below 1 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" +90.1-2007,4,Enclosed,1800,1,1.499,0.825,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,1.5,1.999,0.84,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,2,2.999,0.84,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,3,4.999,0.875,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,5,7.499,0.875,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,7.5,9.999,0.895,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,10,14.999,0.895,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,15,19.999,0.91,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,20,24.999,0.91,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,25,29.999,0.924,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,30,39.999,0.924,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,40,49.999,0.93,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,50,59.999,0.93,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,60,74.999,0.936,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,75,99.999,0.941,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,100,124.999,0.945,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,125,149.999,0.945,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,150,199.999,0.95,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,200,9999,0.95,From 90.1-2007 Table 10.8 +90.1-2010,4,Enclosed,1800,0,0.999,0.29,"Motors below 1 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" +90.1-2010,4,Enclosed,1800,1,1.499,0.855,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,1.5,1.999,0.865,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,2,2.999,0.865,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,3,4.999,0.895,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,5,7.499,0.895,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,7.5,9.999,0.917,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,10,14.999,0.917,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,15,19.999,0.924,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,20,24.9999,0.93,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,25,29.999,0.936,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,30,39.999,0.936,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,40,49.999,0.941,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,50,59.999,0.945,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,60,74.999,0.95,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,75,99.999,0.954,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,100,124.999,0.954,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,125,149.999,0.954,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,150,199.999,0.958,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,200,249.999,0.962,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,250,299.999,0.962,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,300,349.999,0.962,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,350,399.999,0.962,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,400,449.999,0.962,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,450,499.999,0.962,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,500,9999,0.962,From 90.1-2010 Table 10.8B +90.1-2013,4,Enclosed,1800,0,0.08333,0.29,"Motors below 1/12 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" +90.1-2013,4,Enclosed,1800,0.08334,0.999,0.7,"Motors between 1/12 and 1 HP must be EC, with minimum efficiency of 70% per PNNL" +90.1-2013,4,Enclosed,1800,1,1.499,0.855, +90.1-2013,4,Enclosed,1800,1.5,1.999,0.865, +90.1-2013,4,Enclosed,1800,2,2.999,0.865, +90.1-2013,4,Enclosed,1800,3,4.999,0.895, +90.1-2013,4,Enclosed,1800,5,7.499,0.895, +90.1-2013,4,Enclosed,1800,7.5,9.999,0.917, +90.1-2013,4,Enclosed,1800,10,14.999,0.917, +90.1-2013,4,Enclosed,1800,15,19.999,0.924, +90.1-2013,4,Enclosed,1800,20,24.999,0.93, +90.1-2013,4,Enclosed,1800,25,29.999,0.936, +90.1-2013,4,Enclosed,1800,30,39.999,0.936, +90.1-2013,4,Enclosed,1800,40,49.999,0.941, +90.1-2013,4,Enclosed,1800,50,59.999,0.945, +90.1-2013,4,Enclosed,1800,60,74.999,0.95, +90.1-2013,4,Enclosed,1800,75,99.999,0.954, +90.1-2013,4,Enclosed,1800,100,124.999,0.954, +90.1-2013,4,Enclosed,1800,125,149.999,0.954, +90.1-2013,4,Enclosed,1800,150,199.999,0.958, +90.1-2013,4,Enclosed,1800,200,249.999,0.962, +90.1-2013,4,Enclosed,1800,250,299.999,0.95, +90.1-2013,4,Enclosed,1800,300,349.999,0.954, +90.1-2013,4,Enclosed,1800,350,399.999,0.954, +90.1-2013,4,Enclosed,1800,400,449.999,0.954, +90.1-2013,4,Enclosed,1800,450,499.999,0.954, +90.1-2013,4,Enclosed,1800,500,9999,0.954, +90.1-2016,4,Enclosed,1800,0,0.08333,0.29,"Motors below 1/12 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" +90.1-2016,4,Enclosed,1800,0.08334,0.999,0.7,"Motors between 1/12 and 1 HP must be EC, with minimum efficiency of 70% per PNNL" +90.1-2016,4,Enclosed,1800,1,1.499,0.855, +90.1-2016,4,Enclosed,1800,1.5,1.999,0.865, +90.1-2016,4,Enclosed,1800,2,2.999,0.865, +90.1-2016,4,Enclosed,1800,3,4.999,0.895, +90.1-2016,4,Enclosed,1800,5,7.499,0.895, +90.1-2016,4,Enclosed,1800,7.5,9.999,0.917, +90.1-2016,4,Enclosed,1800,10,14.999,0.917, +90.1-2016,4,Enclosed,1800,15,19.999,0.924, +90.1-2016,4,Enclosed,1800,20,24.999,0.93, +90.1-2016,4,Enclosed,1800,25,29.999,0.936, +90.1-2016,4,Enclosed,1800,30,39.999,0.936, +90.1-2016,4,Enclosed,1800,40,49.999,0.941, +90.1-2016,4,Enclosed,1800,50,59.999,0.945, +90.1-2016,4,Enclosed,1800,60,74.999,0.95, +90.1-2016,4,Enclosed,1800,75,99.999,0.954, +90.1-2016,4,Enclosed,1800,100,124.999,0.954, +90.1-2016,4,Enclosed,1800,125,149.999,0.954, +90.1-2016,4,Enclosed,1800,150,199.999,0.958, +90.1-2016,4,Enclosed,1800,200,249.999,0.962, +90.1-2016,4,Enclosed,1800,250,299.999,0.962, +90.1-2016,4,Enclosed,1800,300,349.999,0.962, +90.1-2016,4,Enclosed,1800,350,399.999,0.962, +90.1-2016,4,Enclosed,1800,400,449.999,0.962, +90.1-2016,4,Enclosed,1800,450,499.999,0.962, +90.1-2016,4,Enclosed,1800,500,9999,0.962, +90.1-2019,4,Enclosed,1800,0,0.08333,0.29,"Motors below 1/12 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" +90.1-2019,4,Enclosed,1800,0.08334,0.999,0.7,"Motors between 1/12 and 1 HP must be EC, with minimum efficiency of 70% per PNNL" +90.1-2019,4,Enclosed,1800,1,1.499,0.855, +90.1-2019,4,Enclosed,1800,1.5,1.999,0.865, +90.1-2019,4,Enclosed,1800,2,2.999,0.865, +90.1-2019,4,Enclosed,1800,3,4.999,0.895, +90.1-2019,4,Enclosed,1800,5,7.499,0.895, +90.1-2019,4,Enclosed,1800,7.5,9.999,0.917, +90.1-2019,4,Enclosed,1800,10,14.999,0.917, +90.1-2019,4,Enclosed,1800,15,19.999,0.924, +90.1-2019,4,Enclosed,1800,20,24.999,0.93, +90.1-2019,4,Enclosed,1800,25,29.999,0.936, +90.1-2019,4,Enclosed,1800,30,39.999,0.936, +90.1-2019,4,Enclosed,1800,40,49.999,0.941, +90.1-2019,4,Enclosed,1800,50,59.999,0.945, +90.1-2019,4,Enclosed,1800,60,74.999,0.95, +90.1-2019,4,Enclosed,1800,75,99.999,0.954, +90.1-2019,4,Enclosed,1800,100,124.999,0.954, +90.1-2019,4,Enclosed,1800,125,149.999,0.954, +90.1-2019,4,Enclosed,1800,150,199.999,0.958, +90.1-2019,4,Enclosed,1800,200,249.999,0.962, +90.1-2019,4,Enclosed,1800,250,299.999,0.962, +90.1-2019,4,Enclosed,1800,300,349.999,0.962, +90.1-2019,4,Enclosed,1800,350,399.999,0.962, +90.1-2019,4,Enclosed,1800,400,449.999,0.962, +90.1-2019,4,Enclosed,1800,450,499.999,0.962, +90.1-2019,4,Enclosed,1800,500,9999,0.962, diff --git a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_unitary_air_conditioners_90_1.csv b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_unitary_air_conditioners_90_1.csv new file mode 100644 index 0000000000..51d10b80ba --- /dev/null +++ b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_unitary_air_conditioners_90_1.csv @@ -0,0 +1,196 @@ +template,cooling_type,heating_type,subcategory,minimum_capacity,maximum_capacity,start_date,end_date,minimum_seasonal_efficiency,minimum_energy_efficiency_ratio,minimum_integrated_part_load_value,minimum_integrated_energy_efficiency_ratio,ptac_eer_coefficient_1,ptac_eer_coefficient_2,minimum_scop,cool_cap_ft,cool_cap_fflow,cool_eir_ft,cool_eir_fflow,cool_plf_fplr,annotation +90.1-2004,AirCooled,All Other,PTAC,0,9999999,9/9/1919,9/9/2999,,,,,12.5,0.213,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2004,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,9.7,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,9.5,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,All Other,Single Package,240000,759999,9/9/1919,9/9/2999,,9.3,9.5,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,All Other,Single Package,760000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,10,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,9.5,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,All Other,Split System,240000,759999,9/9/1919,9/9/2999,,9.3,9.5,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,All Other,Split System,760000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,Electric Resistance or None,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.2,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2004 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" +90.1-2004,AirCooled,Electric Resistance or None,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.1,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2004 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" +90.1-2004,AirCooled,Electric Resistance or None,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,1.9,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2004 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" +90.1-2004,AirCooled,Electric Resistance or None,PTAC,0,9999999,9/9/1919,9/9/2999,,,,,12.5,0.213,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2004,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,9.7,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,10.3,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,9.7,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,Electric Resistance or None,Single Package,240000,759999,9/9/1919,9/9/2999,,9.5,9.7,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,Electric Resistance or None,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.2,9.4,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,10,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,10.3,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,9.7,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,Electric Resistance or None,Split System,240000,759999,9/9/1919,9/9/2999,,9.5,9.7,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,Electric Resistance or None,Split System,760000,9999999,9/9/1919,9/9/2999,,9.2,9.4,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,WaterCooled,All Other,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.6,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2004 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" +90.1-2004,WaterCooled,All Other,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.5,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2004 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" +90.1-2004,WaterCooled,All Other,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,2.4,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2004 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" +90.1-2007,AirCooled,All Other,PTAC,0,9999999,9/9/1919,9/9/2999,,,,,12.5,0.213,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2007,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,9.5,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,All Other,Single Package,240000,759999,9/9/1919,9/9/2999,,9.3,9.5,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,All Other,Single Package,760000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,9.5,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,All Other,Split System,240000,759999,9/9/1919,9/9/2999,,9.3,9.5,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,All Other,Split System,760000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,Electric Resistance or None,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.2,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2007 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" +90.1-2007,AirCooled,Electric Resistance or None,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.1,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2007 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" +90.1-2007,AirCooled,Electric Resistance or None,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,1.9,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2007 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" +90.1-2007,AirCooled,Electric Resistance or None,PTAC,0,9999999,9/9/1919,9/9/2999,,,,,12.5,0.213,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2007,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,10.3,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,9.7,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,Electric Resistance or None,Single Package,240000,759999,9/9/1919,9/9/2999,,9.5,9.7,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,Electric Resistance or None,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.2,9.4,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,10.3,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,9.7,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,Electric Resistance or None,Split System,240000,759999,9/9/1919,9/9/2999,,9.5,9.7,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,Electric Resistance or None,Split System,760000,9999999,9/9/1919,9/9/2999,,9.2,9.4,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,WaterCooled,All Other,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.6,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2007 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" +90.1-2007,WaterCooled,All Other,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.5,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2007 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" +90.1-2007,WaterCooled,All Other,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,2.4,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2007 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" +90.1-2010,AirCooled,All Other,PTAC,0,9999999,9/9/1919,9/9/2999,,,,,13.8,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2010,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2010,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,11,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2010,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,10.8,,,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, +90.1-2010,AirCooled,All Other,Single Package,240000,759999,9/9/1919,9/9/2999,,9.8,,9.7,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, +90.1-2010,AirCooled,All Other,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.5,,9.2,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, +90.1-2010,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2010,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,11,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2010,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,10.8,,,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, +90.1-2010,AirCooled,All Other,Split System,240000,759999,9/9/1919,9/9/2999,,9.8,,9.7,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, +90.1-2010,AirCooled,All Other,Split System,760000,9999999,9/9/1919,9/9/2999,,9.5,,9.2,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, +90.1-2010,AirCooled,Electric Resistance or None,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.2,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for downflow units +90.1-2010,AirCooled,Electric Resistance or None,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.1,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for downflow units +90.1-2010,AirCooled,Electric Resistance or None,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,1.9,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for downflow units +90.1-2010,AirCooled,Electric Resistance or None,PTAC,0,9999999,9/9/1919,9/9/2999,,,,,13.8,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2010,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2010,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,11.2,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2010,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,11,,,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, +90.1-2010,AirCooled,Electric Resistance or None,Single Package,240000,759999,9/9/1919,9/9/2999,,10,,9.7,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, +90.1-2010,AirCooled,Electric Resistance or None,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.7,,9.4,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, +90.1-2010,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2010,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,11.2,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2010,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,11,,,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, +90.1-2010,AirCooled,Electric Resistance or None,Split System,240000,759999,9/9/1919,9/9/2999,,10,,9.7,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, +90.1-2010,AirCooled,Electric Resistance or None,Split System,760000,9999999,9/9/1919,9/9/2999,,9.7,,9.4,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, +90.1-2010,WaterCooled,All Other,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.6,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units +90.1-2010,WaterCooled,All Other,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.5,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units +90.1-2010,WaterCooled,All Other,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,2.4,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units +90.1-2013,AirCooled,All Other,PTAC,0,9999999,9/9/1919,12/31/2014,,,,,13.8,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2013,AirCooled,All Other,PTAC,0,9999999,1/1/2015,9/9/2999,,,,,14,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2013,AirCooled,All Other,Single Package,0,64999,9/9/1919,12/31/2014,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Single Package,0,64999,1/1/2015,9/9/2999,14,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Single Package,65000,134999,9/9/1919,12/31/2015,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Single Package,135000,239999,9/9/1919,12/31/2015,,10.8,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Single Package,240000,759999,9/9/1919,12/31/2015,,9.8,,9.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Single Package,760000,9999999,9/9/1919,12/31/2015,,9.5,,9.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Single Package,65000,134999,1/1/2016,9/9/2999,,11,,12.7,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Single Package,135000,239999,1/1/2016,9/9/2999,,10.8,,12.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Single Package,240000,759999,1/1/2016,9/9/2999,,9.8,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Single Package,760000,9999999,1/1/2016,9/9/2999,,9.5,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Split System,65000,134999,9/9/1919,12/31/2015,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Split System,135000,239999,9/9/1919,12/31/2015,,10.8,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Split System,240000,759999,9/9/1919,12/31/2015,,9.8,,9.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Split System,760000,9999999,9/9/1919,12/31/2015,,9.5,,9.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Split System,65000,134999,1/1/2016,9/9/2999,,11,,12.7,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Split System,135000,239999,1/1/2016,9/9/2999,,10.8,,12.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Split System,240000,759999,1/1/2016,9/9/2999,,9.8,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Split System,760000,9999999,1/1/2016,9/9/2999,,9.5,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.2,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units +90.1-2013,AirCooled,Electric Resistance or None,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.1,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units +90.1-2013,AirCooled,Electric Resistance or None,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,1.9,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units +90.1-2013,AirCooled,Electric Resistance or None,PTAC,0,9999999,9/9/1919,12/31/2014,,,,,13.8,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2013,AirCooled,Electric Resistance or None,PTAC,0,9999999,1/1/2015,9/9/2999,,,,,14,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2013,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,12/31/2014,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Single Package,0,64999,1/1/2015,9/9/2999,14,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,12/31/2015,,11.2,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,12/31/2015,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Single Package,240000,759999,9/9/1919,12/31/2015,,10,,10.1,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Single Package,760000,9999999,9/9/1919,12/31/2015,,9.7,,9.8,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Single Package,65000,134999,1/1/2016,9/9/2999,,11.2,,12.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Single Package,135000,239999,1/1/2016,9/9/2999,,11,,12.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Single Package,240000,759999,1/1/2016,9/9/2999,,10,,11.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Single Package,760000,9999999,1/1/2016,9/9/2999,,9.7,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,12/31/2015,,11.2,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,12/31/2015,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Split System,240000,759999,9/9/1919,12/31/2015,,10,,10.1,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Split System,760000,9999999,9/9/1919,12/31/2015,,9.7,,9.8,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Split System,65000,134999,1/1/2016,9/9/2999,,11.2,,12.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Split System,135000,239999,1/1/2016,9/9/2999,,11,,12.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Split System,240000,759999,1/1/2016,9/9/2999,,10,,11.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Split System,760000,9999999,1/1/2016,9/9/2999,,9.7,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,WaterCooled,All Other,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.6,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units +90.1-2013,WaterCooled,All Other,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.5,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units +90.1-2013,WaterCooled,All Other,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,2.4,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units +90.1-2016,AirCooled,All Other,PTAC,0,9999999,9/9/1919,12/31/2014,,,,,13.8,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,All Other,PTAC,0,9999999,1/1/2015,9/9/2999,,,,,14,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,14,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,10.8,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,All Other,Single Package,240000,759999,9/9/1919,9/9/2999,,9.8,,9.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,All Other,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.5,,9.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,10.8,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,All Other,Split System,240000,759999,9/9/1919,9/9/2999,,9.8,,9.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,All Other,Split System,760000,9999999,9/9/1919,9/9/2999,,9.5,,9.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,Electric Resistance or None,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.3,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units +90.1-2016,AirCooled,Electric Resistance or None,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.2,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units +90.1-2016,AirCooled,Electric Resistance or None,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,2,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units +90.1-2016,AirCooled,Electric Resistance or None,PTAC,0,9999999,9/9/1919,12/31/2014,,,,,13.8,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,Electric Resistance or None,PTAC,0,9999999,1/1/2015,9/9/2999,,,,,14,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,12/31/2014,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,Electric Resistance or None,Single Package,0,64999,1/1/2015,9/9/2999,14,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,11.2,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,Electric Resistance or None,Single Package,240000,759999,9/9/1919,9/9/2999,,10,,10.1,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,Electric Resistance or None,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.7,,9.8,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,11.2,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,Electric Resistance or None,Split System,240000,759999,9/9/1919,9/9/2999,,10,,10.1,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,Electric Resistance or None,Split System,760000,9999999,9/9/1919,9/9/2999,,9.7,,9.8,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,WaterCooled,All Other,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.5,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units +90.1-2016,WaterCooled,All Other,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.4,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units +90.1-2016,WaterCooled,All Other,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,2.25,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units +90.1-2019,AirCooled,All Other,PTAC,0,6999,9/9/1919,9/9/2999,,11.9,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,PTAC,6999,14999,9/9/1919,9/9/2999,,,,,14,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,PTAC,14999,9999999,9/9/1919,9/9/2999,,9.5,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,14,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,11,,12.7,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,10.8,,12.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,All Other,Single Package,240000,759999,9/9/1919,9/9/2999,,9.8,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,All Other,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.5,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,11,,12.7,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,10.8,,12.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,All Other,Split System,240000,759999,9/9/1919,9/9/2999,,9.8,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,All Other,Split System,760000,9999999,9/9/1919,9/9/2999,,9.5,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,Electric Resistance or None,CRAC,0,79999,9/9/1919,9/9/2999,,,,,,,2.7,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for downflow units +90.1-2019,AirCooled,Electric Resistance or None,CRAC,80000,294999,9/9/1919,9/9/2999,,,,,,,2.58,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for downflow units +90.1-2019,AirCooled,Electric Resistance or None,CRAC,295000,9999999,9/9/1919,9/9/2999,,,,,,,2.36,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for downflow units +90.1-2019,AirCooled,Electric Resistance or None,PTAC,0,6999,9/9/1919,9/9/2999,,11.9,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,PTAC,6999,14999,9/9/1919,9/9/2999,,,,,14,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,PTAC,14999,9999999,9/9/1919,9/9/2999,,9.5,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,14,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,11.2,,12.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,11,,12.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,Electric Resistance or None,Single Package,240000,759999,9/9/1919,9/9/2999,,10,,11.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,Electric Resistance or None,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.7,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,11.2,,12.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,11,,12.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,Electric Resistance or None,Split System,240000,759999,9/9/1919,9/9/2999,,10,,11.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,Electric Resistance or None,Split System,760000,9999999,9/9/1919,9/9/2999,,9.7,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,WaterCooled,All Other,CRAC,0,79999,9/9/1919,9/9/2999,,,,,,,2.82,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for water cooled downflow units +90.1-2019,WaterCooled,All Other,CRAC,80000,294999,9/9/1919,9/9/2999,,,,,,,2.73,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for water cooled downflow units +90.1-2019,WaterCooled,All Other,CRAC,295000,9999999,9/9/1919,9/9/2999,,,,,,,2.67,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for water cooled downflow units diff --git a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_water_heaters_90_1.csv b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_water_heaters_90_1.csv new file mode 100644 index 0000000000..67ef79f434 --- /dev/null +++ b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_water_heaters_90_1.csv @@ -0,0 +1,25 @@ +template,fuel_type,minimum_capacity,maximum_capacity,start_date,end_date,energy_factor_base,energy_factor_volume_derate,standby_loss_base,standby_loss_capacity_allowance,standby_loss_volume_allowance,hourly_loss_base,hourly_loss_volume_allowance,thermal_efficiency,annotation +90.1-2004,Electricity,0,40945.99,9/9/1919,9/9/2999,0.93,0.00132,,,,,,,From 90.1-2004 Table 7.8 +90.1-2004,Electricity,40946,99999999,9/9/1919,9/9/2999,,,20,,35,,,,From 90.1-2004 Table 7.8 +90.1-2004,NaturalGas,0,74999.99,9/9/1919,9/9/2999,0.62,0.0019,,,,,,,From 90.1-2004 Table 7.8 +90.1-2004,NaturalGas,75000,99999999,9/9/1919,9/9/2999,,,,800,110,,,0.8,From 90.1-2004 Table 7.8 +90.1-2007,Electricity,0,40945.99,9/9/1919,9/9/2999,0.93,0.00132,,,,,,,From 90.1-2007 Table 7.8 +90.1-2007,Electricity,40946,99999999,9/9/1919,9/9/2999,,,20,,35,,,,From 90.1-2007 Table 7.8 +90.1-2007,NaturalGas,0,74999.99,9/9/1919,9/9/2999,0.62,0.0019,,,,,,,From 90.1-2007 Table 7.8 +90.1-2007,NaturalGas,75000,99999999,9/9/1919,9/9/2999,,,,800,110,,,0.8,From 90.1-2007 Table 7.8 +90.1-2010,Electricity,0,40945.99,9/9/1919,9/9/2999,0.97,0.00132,,,,,,,From 90.1-2010 Table 7.8 +90.1-2010,Electricity,40946,99999999,9/9/1919,9/9/2999,,,20,,35,,,,From 90.1-2010 Table 7.8 +90.1-2010,NaturalGas,0,74999.99,9/9/1919,9/9/2999,0.67,0.0019,,,,,,,From 90.1-2010 Table 7.8 +90.1-2010,NaturalGas,75000,99999999,9/9/1919,9/9/2999,,,,800,110,,,0.8,From 90.1-2010 Table 7.8 +90.1-2013,Electricity,0,40945.99,9/9/1919,9/9/2999,0.97,0.00132,,,,,,,From 90.1-2013 Table 7.8 +90.1-2013,Electricity,40946,99999999,9/9/1919,9/9/2999,,,,,,0.3,27,,From 90.1-2013 Table 7.8 +90.1-2013,NaturalGas,0,74999.99,9/9/1919,9/9/2999,0.67,0.0019,,,,,,,From 90.1-2013 Table 7.8 +90.1-2013,NaturalGas,75000,99999999,9/9/1919,9/9/2999,,,,800,110,,,0.8,From 90.1-2013 Table 7.8 +90.1-2016,Electricity,0,40945.99,9/9/1919,9/9/2999,0.96,0.0003,,,,,,,"From 90.1-2016 Table F-2, Rated Storage Volume <= 55 gal" +90.1-2016,Electricity,40946,99999999,9/9/1919,9/9/2999,,,,,,0.3,27,, +90.1-2016,NaturalGas,0,74999.99,9/9/1919,9/9/2999,0.675,0.0015,,,,,,,"From 90.1-2016 Table F-2, Rated Storage Volume <= 55 gal" +90.1-2016,NaturalGas,75000,99999999,9/9/1919,9/9/2999,,,,800,110,,,0.8, +90.1-2019,Electricity,0,40945.99,9/9/1919,9/9/2999,0.96,0.0003,,,,,,,Same as 90.1-2016 as placeholder; 90.1-2019 Table F-2 uses UEF +90.1-2019,Electricity,40946,99999999,9/9/1919,9/9/2999,,,,,,0.3,27,, +90.1-2019,NaturalGas,0,74999.99,9/9/1919,9/9/2999,0.675,0.0015,,,,,,,Same as 90.1-2016 as placeholder; 90.1-2019 Table F-2 uses UEF +90.1-2019,NaturalGas,75000,99999999,9/9/1919,9/9/2999,,,,800,110,,,0.8, diff --git a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1.csv b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1.csv new file mode 100644 index 0000000000..3ef18bfab7 --- /dev/null +++ b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1.csv @@ -0,0 +1,19 @@ +template,minimum_capacity,maximum_capacity,start_date,end_date,minimum_full_load_efficiency,annotation +90.1-2004,0,16999,9/9/1919,9/9/2999,11.2,From 90.1-2004 Table 6.8.1B +90.1-2004,17000,64999,9/9/1919,9/9/2999,12,From 90.1-2004 Table 6.8.1B +90.1-2004,65000,134999,9/9/1919,9/9/2999,12,From 90.1-2004 Table 6.8.1B +90.1-2007,0,16999,9/9/1919,9/9/2999,11.2,From 90.1-2007 Table 6.8.1B +90.1-2007,17000,64999,9/9/1919,9/9/2999,12,From 90.1-2007 Table 6.8.1B +90.1-2007,65000,134999,9/9/1919,9/9/2999,12,From 90.1-2007 Table 6.8.1B +90.1-2010,0,16999,9/9/1919,9/9/2999,11.2,From 90.1-2010 Table 6.8.1B +90.1-2010,17000,64999,9/9/1919,9/9/2999,12,From 90.1-2010 Table 6.8.1B +90.1-2010,65000,134999,9/9/1919,9/9/2999,12,From 90.1-2010 Table 6.8.1B +90.1-2013,0,16999,9/9/1919,9/9/2999,12.2,From 90.1-2013 Table 6.8.1-2 +90.1-2013,17000,64999,9/9/1919,9/9/2999,13,From 90.1-2013 Table 6.8.1-2 +90.1-2013,65000,134999,9/9/1919,9/9/2999,13,From 90.1-2013 Table 6.8.1-2 +90.1-2016,0,16999,9/9/1919,9/9/2999,12.2, +90.1-2016,17000,64999,9/9/1919,9/9/2999,13, +90.1-2016,65000,134999,9/9/1919,9/9/2999,13, +90.1-2019,0,16999,9/9/1919,9/9/2999,12.2, +90.1-2019,17000,64999,9/9/1919,9/9/2999,13, +90.1-2019,65000,134999,9/9/1919,9/9/2999,13, diff --git a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_water_source_heat_pumps_heating_90_1.csv b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_water_source_heat_pumps_heating_90_1.csv new file mode 100644 index 0000000000..2359b75f6d --- /dev/null +++ b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_water_source_heat_pumps_heating_90_1.csv @@ -0,0 +1,7 @@ +template,minimum_capacity,maximum_capacity,start_date,end_date,minimum_coefficient_of_performance,annotation +90.1-2004,0,9999999,9/9/1919,9/9/2999,4.2,From 90.1-2004 Table 6.8.1B +90.1-2007,0,9999999,9/9/1919,9/9/2999,4.2,From 90.1-2007 Table 6.8.1B +90.1-2010,0,9999999,9/9/1919,9/9/2999,4.2,From 90.1-2010 Table 6.8.1B +90.1-2013,0,9999999,9/9/1919,9/9/2999,4.3,From 90.1-2013 Table 6.8.1-2 +90.1-2016,0,9999999,9/9/1919,9/9/2999,4.3,From 90.1-2016 Table 6.8.1-2 +90.1-2019,0,9999999,9/9/1919,9/9/2999,4.3,From 90.1-2016 Table 6.8.1-15 diff --git a/data/openstudio_standards_data/initial_data/level_1_space_types.csv b/data/openstudio_standards_data/initial_data/level_1_space_types.csv new file mode 100644 index 0000000000..5c4109760b --- /dev/null +++ b/data/openstudio_standards_data/initial_data/level_1_space_types.csv @@ -0,0 +1,129 @@ +id,space_type_name,lighting_space_type_name,ventilation_space_type_name,electric_equipment_space_type_name +1,chapel - visually impaired,chapel_visually_impaired,public_assembly_spaces_religious_workshop, +2,recreation/common living - visually impaired,recreation_common_living_visually_impaired,hotels_motels_resorts_dormitories_multi_purpose_assembly, +3,atrium < 20 ft height,atrium_low,office_buildings_main_entry_lobbies,atrium < 20 ft height +4,atrium >= 20 ft and <= 40 ft in height,atrium_medium,office_buildings_main_entry_lobbies,atrium >= 20 ft and <= 40 ft in height +5,atrium > 40 ft height,atrium_high,office_buildings_main_entry_lobbies,atrium > 40 ft height +6,audience seating - convention center,audience_seating_convention_center,public_assembly_spaces_auditorium_seating_area,audience seating - convention center +7,audience seating - exercise center,audience_seating_exercise_center,sports_entertainment_spectator_areas,audience seating - exercise center +8,audience seating - all other,audience_seating_general,public_assembly_spaces_auditorium_seating_area,audience seating - all other +9,audience seating - auditorium,audience_seating_auditorium,public_assembly_spaces_auditorium_seating_area,audience seating - auditorium +10,audience seating - gymnasium,audience_seating_gymnasium,sports_entertainment_spectator_areas,audience seating - gymnasium +11,audience seating - sports arena,audience_seating_sports_arena,sports_entertainment_spectator_areas,audience seating - sports arena +12,audience seating - motion picture theater,audience_seating_motion_picture_theater,public_assembly_spaces_auditorium_seating_area,audience seating - motion picture theater +13,audience seating - penitentiary,audience_seating_penitentiary,public_assembly_spaces_auditorium_seating_area, +14,audience seating - performing arts theater,audience_seating_performing_arts_theater,public_assembly_spaces_auditorium_seating_area,audience seating - performing arts theater +15,audience seating - religious facility,audience_seating_religious_facility,public_assembly_spaces_auditorium_seating_area,audience seating - religious facility +16,audience seating - transportation facility,audience_seating_transportation,public_assembly_spaces_auditorium_seating_area, +17,automotive,automotive,miscellaneous_spaces_transportation_waiting, +18,banking activity,banking_activity,miscellaneous_spaces_banks_bank_lobbies,banking activity +19,classroom/lecture/training - all other,classroom_lecture_training_general,educational_facilities_classroom_old,classroom/lecture/training - all other +20,classroom/lecture/training - penitentiary,classroom_lecture_training_penitentiary,correctional_facilities_dayroom,classroom/lecture/training - penitentiary +21,classroom - laboratory or shop,laboratory_classroom,educational_facilities_university_college_laboratories, +22,classroom/lecture/training - preschool to 12th,classroom_lecture_training_general,educational_facilities_classroom_young,classroom/lecture/training - preschool to 12th +23,computer room,computer_room,miscellaneous_spaces_computer,computer room +24,conference/meeting/multipurpose,conference_meeting_multipurpose,general_conference_meeting,conference/meeting/multipurpose +25,confinement cells,confinement_cells,correctional_facilities_cell,confinement cells +26,exhibit - convention center,exhibit_convention_center,public_assembly_spaces_museums_galleries,exhibit - convention center +27,copy/print,copy_print,office_buildings_telephone_data_entry, +28,corridor for visually impaired,corridor_visually_impaired,general_conference_corridors, +29,corridor - hospital,corridor_hospital,general_conference_corridors,corridor - hospital +30,corridor - manufacturing facility,corridor_manufacturing_facility,general_conference_corridors,corridor - manufacturing facility +31,corridor - all other,corridor_general,general_conference_corridors,corridor - all other +32,courtroom,courtroom,public_assembly_spaces_courtrooms,courtroom +33,dining - all other,dining_general,food_beverage_service_restaurant_dining_rooms,dining - all other +34,dining - bar/lounge/leisure,dining_bar_lounge_leisure,food_beverage_service_bars_cocktail_lounges,dining - bar/lounge/leisure +35,dining - cafeteria/fast food,dining_cafeteria_fast_food,food_beverage_service_cafeteria_fast_food_dining,dining - cafeteria/fast food +36,dining for visually impaired,dining_visually_impaired,food_beverage_service_restaurant_dining_rooms, +37,dining - family,dining_family,food_beverage_service_restaurant_dining_rooms,dining - family +38,dining - penitentiary,dining_penitentiary,food_beverage_service_restaurant_dining_rooms,dining - penitentiary +39,dining - hotel,dining_hotel,food_beverage_service_restaurant_dining_rooms, +40,dining - motel,dining_motel,food_beverage_service_restaurant_dining_rooms, +41,dormitory - living quarters,dormitory_living_quarters,hotels_motels_resorts_dormitories_bedroom_living_room,dormitory - living quarters +42,electrical/mechanical,electrical_mechanical,miscellaneous_spaces_manufacturing_wo_hazardous_materials,electrical/mechanical +43,emergency vehicle garage,emergency_vehicle_garage,miscellaneous_spaces_transportation_waiting,emergency vehicle garage +44,firestation - sleeping quarters,firestation_sleeping_quarters,hotels_motels_resorts_dormitories_barracks_sleeping_areas,firestation - sleeping quarters +45,kitchen,kitchen,food_beverage_service_kitchen,kitchen +46,guest room,guest_room,hotels_motels_resorts_dormitories_barracks_sleeping_areas,guest room +47,gymnasium exercise area,gymnasium_exercise_area,sports_entertainment_gym_stadium,gymnasium exercise area +48,gymnasium playing area,gymnasium_playing_area,sports_entertainment_gym_stadium,gymnasium playing area +49,emergency room,emergency_room,outpatient_health_care_facilities_general_examination_room,emergency room +50,exam/treatment,exam_treatment,outpatient_health_care_facilities_general_examination_room,exam/treatment +51,imaging,imaging,outpatient_health_care_facilities_class_1_imaging_rooms, +52,medical supply,medical_supply,miscellaneous_spaces_pharmacy, +53,nursery,nursery,outpatient_health_care_facilities_psychiatric_consultation_room, +54,nurses station,nurses_station,outpatient_health_care_facilities_psychiatric_consultation_room,nurses station +55,operating room,operating_room,outpatient_health_care_facilities_general_examination_room,operating room +56,patient room,patient_room,outpatient_health_care_facilities_physical_therapy_individual_room,patient room +57,physical therapy,physical_therapy,outpatient_health_care_facilities_physical_therapy_exercise_area,physical therapy +58,recovery,recovery,outpatient_health_care_facilities_urgent_care_examination_room, +59,judges chambers,judges_chambers,public_assembly_spaces_legislative_chambers,judges chambers +60,laboratory,laboratory_all_other,educational_facilities_science_laboratories,laboratory +61,library - reading,library_reading,public_assembly_spaces_libraries,library - reading +62,library - stacks,library_stacks,public_assembly_spaces_libraries,library - stacks +63,library - cataloging,library_cataloging,public_assembly_spaces_libraries,library - cataloging +64,loading dock,loading_dock,miscellaneous_spaces_sorting_packing_light_assembly, +65,lobby - all other,lobby_general,public_assembly_spaces_lobbies,lobby - all other +66,lobby - elevator,lobby_elevator,public_assembly_spaces_lobbies,lobby - elevator +67,lobby for visually impaired,lobby_visually_impaired,public_assembly_spaces_lobbies, +68,lobby - hotel,lobby_hotel,hotels_motels_resorts_dormitories_lobbies_prefunction,lobby - hotel +69,lobby - motion picture theater,lobby_motion_picture_theater,public_assembly_spaces_lobbies,lobby - motion picture theater +70,lobby - performing arts theater,lobby_performing_arts_theater,public_assembly_spaces_lobbies,lobby - performing arts theater +71,locker room,locker_room,general_break_rooms,locker room +72,lounge/breakroom - all other,lounge_breakroom_general,general_break_rooms,lounge/breakroom - all other +73,lounge/breakroom - healthcare facility,lounge_breakroom_healthcare_facility,general_break_rooms,lounge/breakroom - healthcare facility +74,laundry/washing,laundry_washing,hotels_motels_resorts_dormitories_laundry_rooms,laundry/washing +75,detailed manufacuring,detailed_manufacuring,miscellaneous_spaces_manufacturing_wo_hazardous_materials, +76,manufacturing equipment room,manufacturing_equipment_room,miscellaneous_spaces_manufacturing_wo_hazardous_materials,manufacturing equipment room +77,manufacturing extra high bay,manufacturing_extra_high_bay,miscellaneous_spaces_manufacturing_wo_hazardous_materials, +78,manufacturing high bay,manufacturing_high_bay,miscellaneous_spaces_manufacturing_wo_hazardous_materials, +79,manufacturing low bay,manufacturing_low_bay,miscellaneous_spaces_manufacturing_wo_hazardous_materials,manufacturing low bay +80,manufacturing control,manufacturing_control,miscellaneous_spaces_manufacturing_wo_hazardous_materials, +81,museum exhibit area,museum_exhibit_area,public_assembly_spaces_museums_galleries,museum exhibit area +82,museum restoration,museum_restoration,public_assembly_spaces_museums_galleries,museum restoration +83,performing arts dressing room,performing_arts_dressing_room,retail_mall_common_areas,performing arts dressing room +84,office - enclosed <= 250 sf,office_enclosed_small,office_buildings_office_space,office - enclosed <= 250 sf +85,office - enclosed > 250 sf,office_enclosed_large,office_buildings_office_space,office - enclosed > 250 sf +86,office - open,office_open,office_buildings_office_space,office - open +87,"parking area, interior",parking_area_interior,miscellaneous_spaces_transportation_waiting,"parking area, interior" +88,pharmacy,pharmacy,miscellaneous_spaces_pharmacy,pharmacy +89,post office - sorting area,post_office_sorting_area,miscellaneous_spaces_sorting_packing_light_assembly,post office - sorting area +90,fellowship hall - religious facility,fellowship_hall_religious_facility,public_assembly_spaces_religious_workshop,fellowship hall - religious facility +91,worship/pulpit/choir area,worship_pulpit_choir_area,public_assembly_spaces_religious_workshop,worship/pulpit/choir area +92,restroom - all other,restroom_all_other,,restroom - all other +93,restroom - visually impaired,restroom_visually_impaired,, +94,retail dressing room,retail_dressing_room,retail_mall_common_areas, +95,retail mall concourse,retail_mall_concourse,retail_mall_common_areas, +96,"seating area, general",seating_area_general,public_assembly_spaces_auditorium_seating_area,"seating area, general" +97,"sports arena playing area, class I",sports_arena_playing_area_class_I,sports_entertainment_sports_arena, +98,"sports arena playing area, class II",sports_arena_playing_area_class_II,sports_entertainment_sports_arena,"sports arena playing area, class II" +99,"sports arena playing area, class III",sports_arena_playing_area_class_III,sports_entertainment_sports_arena, +100,"sports arena playing area, class IV",sports_arena_playing_area_class_IV,sports_entertainment_sports_arena,"sports arena playing area, class IV" +101,sports arena - ring sports area,sports_arena_ring_sports_area,sports_entertainment_sports_arena, +102,sports arena - court sports area,sports_arena_court_sports_area,sports_entertainment_sports_arena, +103,sports arena - indoor playing field,sports_arena_indoor_playing_field,sports_entertainment_sports_arena, +104,stairwell,stairwell,general_conference_corridors,stairwell +105,storage < 50 sf - all other,storage_ all_other_small,general_conference_storage_rooms,storage < 50 sf - all other +106,storage 50 to 1000 sf - all other,storage_ all_other_large,general_conference_storage_rooms,storage 50 to 1000 sf - all other +107,storage < 50 sf - hospital,storage_hospital_small,general_conference_storage_rooms,storage < 50 sf - hospital +108,storage 50 to 1000 sf - hospital,storage_hospital_large,general_conference_storage_rooms,storage 50 to 1000 sf - hospital +109,storage - inactive,storage_inactive,general_conference_storage_rooms,storage - inactive +110,"storage, inactive - museum",storage_inactive_museum,general_conference_storage_rooms, +111,airport concourse,airport_concourse,office_buildings_reception_areas,airport concourse +112,baggage/carousel,baggage_carousel,office_buildings_reception_areas,baggage/carousel +113,transportation ticket counter,transportation_ticket_counter,office_buildings_reception_areas,transportation ticket counter +114,vehicular maintenance,vehicular_maintenance,miscellaneous_spaces_manufacturing_wo_hazardous_materials,vehicular maintenance +115,warehouse - bulk storage,warehouse_bulk_storage,miscellaneous_spaces_warehouses,warehouse - bulk storage +116,warehouse - fine storage,warehouse_fine_storage,miscellaneous_spaces_warehouses,warehouse - fine storage +117,workshop,workshop,miscellaneous_spaces_manufacturing_wo_hazardous_materials,workshop +118,sales,sales,retail_sales,sales +119,sales - display type 1,sales_display_type_1,retail_sales, +120,sales - display type 2,sales_display_type_2,retail_sales, +121,sales - display type 3,sales_display_type_3,retail_sales, +122,sales - display type 4,sales_display_type_4,retail_sales, +123,guest room - highway,guest_room,hotels_motels_resorts_dormitories_barracks_sleeping_areas, +124,lodging dining - highway,dining_general,food_beverage_service_restaurant_dining_rooms, +125,audience seating - classroom/lecture/training,audience_seating_general,public_assembly_spaces_auditorium_seating_area, +126,audience seating - conference/meeting/multipurpose,audience_seating_general,public_assembly_spaces_auditorium_seating_area, +127,audience seating - corridor/transition,audience_seating_general,public_assembly_spaces_auditorium_seating_area, +128,guest room - bathroom,guest_room,hotels_motels_resorts_dormitories_barracks_sleeping_areas, diff --git a/data/openstudio_standards_data/initial_data/level_2_electric_equipment.csv b/data/openstudio_standards_data/initial_data/level_2_electric_equipment.csv new file mode 100644 index 0000000000..47a8f8ba4e --- /dev/null +++ b/data/openstudio_standards_data/initial_data/level_2_electric_equipment.csv @@ -0,0 +1,91 @@ +id,electric_equipment_space_type_name,electric_equipment_minimum_epd,electric_equipment_average_epd,electric_equipment_median_epd,electric_equipment_maximum_epd,electric_equipment_epd_unit +1,corridor - all other,0,0.28,0.24,0.82,W/ft2 +2,dining - all other,0.32,0.55,0.55,0.82,W/ft2 +3,electrical/mechanical,0,0,0,0,W/ft2 +4,kitchen,0.3,0.76,0.71,2.52,W/ft2 +5,laboratory,0.49,0.78,0.7,2.02,W/ft2 +6,lobby - all other,0.16,0.41,0.35,0.83,W/ft2 +7,locker room,0,0.38,0.44,0.97,W/ft2 +8,lounge/breakroom - all other,0,0.49,0.52,0.88,W/ft2 +9,office - enclosed <= 250 sf,0.51,0.68,0.68,0.89,W/ft2 +10,office - enclosed > 250 sf,0.65,0.7,0.69,0.82,W/ft2 +11,office - open,0.53,0.66,0.67,0.81,W/ft2 +12,restroom - all other,0,0,0,0,W/ft2 +13,stairwell,0,0.25,0.25,0.53,W/ft2 +14,storage < 50 sf - all other,0,0,0,0,W/ft2 +15,storage 50 to 1000 sf - all other,0,0,0,0,W/ft2 +16,vehicular maintenance,0.65,0.69,0.69,0.73,W/ft2 +17,workshop,0,0.54,0.57,0.74,W/ft2 +18,atrium - first three floors,0,0.52,0.54,0.75,W/ft2 +19,audience seating - convention center,0.63,0.63,0.63,0.63,W/ft2 +20,classroom/lecture/training - all other,0.5,0.63,0.62,0.8,W/ft2 +21,conference/meeting/multipurpose,0.42,0.62,0.62,0.97,W/ft2 +22,exhibit - convention center,0.84,0.84,0.84,0.84,W/ft2 +23,gymnasium exercise area,0.27,0.48,0.49,0.68,W/ft2 +24,gymnasium playing area,0,0.51,0.51,1.06,W/ft2 +25,laundry/washing,0,0.39,0.39,0.59,W/ft2 +26,lobby - elevator,0.32,0.32,0.32,0.32,W/ft2 +27,nurses station,0,0.52,0.57,0.85,W/ft2 +28,post office - sorting area,0,0.23,0.24,0.39,W/ft2 +29,sales,0.41,0.67,0.67,0.92,W/ft2 +30,"sports arena playing area, class IV",0.32,0.5,0.64,0.69,W/ft2 +31,audience seating - all other,0.31,0.49,0.46,0.75,W/ft2 +32,confinement cells,0.22,0.26,0.26,0.32,W/ft2 +33,courtroom,0.25,0.4,0.4,0.56,W/ft2 +34,judges chambers,0.5,0.59,0.59,0.68,W/ft2 +35,library - stacks,0,0.2,0.2,0.33,W/ft2 +36,storage - inactive,0,0,0,0,W/ft2 +37,dining - bar/lounge/leisure,0.5,0.5,0.5,0.5,W/ft2 +38,dining - cafeteria/fast food,0.6,0.6,0.6,0.6,W/ft2 +39,dining - family,0.78,0.78,0.78,0.78,W/ft2 +40,computer room,0.69,0.7,0.69,0.73,W/ft2 +41,dormitory - living quarters,0.23,0.44,0.42,0.62,W/ft2 +42,audience seating - exercise center,0.6,0.6,0.6,0.6,W/ft2 +43,exam/treatment,0.51,0.56,0.53,0.66,W/ft2 +44,library - reading,0.32,0.49,0.46,0.71,W/ft2 +45,emergency vehicle garage,0.39,0.39,0.39,0.39,W/ft2 +46,firestation - sleeping quarters,0.37,0.37,0.37,0.37,W/ft2 +47,"parking area, interior",0.11,0.27,0.3,0.32,W/ft2 +48,audience seating - gymnasium,0.64,0.64,0.64,0.64,W/ft2 +49,emergency room,0.61,0.62,0.62,0.62,W/ft2 +50,patient room,0.71,0.72,0.72,0.73,W/ft2 +51,pharmacy,0.47,0.64,0.72,0.74,W/ft2 +52,corridor - hospital,0.3,0.3,0.3,0.3,W/ft2 +53,fellowship hall - religious facility,0.36,0.39,0.39,0.41,W/ft2 +54,lounge/breakroom - healthcare facility,0.75,0.75,0.75,0.75,W/ft2 +55,operating room,0.77,0.77,0.77,0.77,W/ft2 +56,physical therapy,0.73,0.73,0.73,0.73,W/ft2 +57,storage < 50 sf - hospital,0,0,0,0,W/ft2 +58,storage 50 to 1000 sf - hospital,0,0,0,0,W/ft2 +59,guest room,0.47,0.53,0.53,0.58,W/ft2 +60,lobby - hotel,0.5,0.5,0.5,0.5,W/ft2 +61,library - cataloging,0.21,0.21,0.21,0.21,W/ft2 +62,museum exhibit area,0.32,0.46,0.43,0.68,W/ft2 +63,corridor - manufacturing facility,0.38,0.38,0.38,0.38,W/ft2 +64,manufacturing equipment room,0,0,0,0,W/ft2 +65,manufacturing low bay,0.67,0.67,0.67,0.67,W/ft2 +66,performing arts dressing room,0.29,0.41,0.43,0.5,W/ft2 +67,audience seating - auditorium,0.26,0.29,0.29,0.32,W/ft2 +68,audience seating - motion picture theater,0.28,0.28,0.28,0.28,W/ft2 +69,lobby - motion picture theater,0.33,0.33,0.33,0.33,W/ft2 +70,Dwelling Unit,0.25,0.25,0.25,0.25,W/ft2 +71,museum restoration,0.21,0.21,0.21,0.21,W/ft2 +72,banking activity,0.54,0.55,0.55,0.56,W/ft2 +73,warehouse - fine storage,0,0.06,0.06,0.12,W/ft2 +74,classroom/lecture/training - penitentiary,0.41,0.41,0.41,0.41,W/ft2 +75,dining - penitentiary,0.35,0.35,0.35,0.35,W/ft2 +76,audience seating - performing arts theater,0.27,0.27,0.27,0.27,W/ft2 +77,lobby - performing arts theater,0.33,0.33,0.33,0.33,W/ft2 +78,audience seating - religious facility,0.41,0.41,0.41,0.41,W/ft2 +79,worship/pulpit/choir area,0.42,0.42,0.42,0.42,W/ft2 +80,classroom/lecture/training - preschool to 12th,0.67,0.67,0.67,0.67,W/ft2 +81,"sports arena playing area, class II",0.32,0.48,0.48,0.64,W/ft2 +82,audience seating - sports arena,0.38,0.38,0.38,0.38,W/ft2 +83,airport concourse,0.52,0.52,0.52,0.52,W/ft2 +84,atrium < 20 ft height,0.53,0.53,0.53,0.53,W/ft2 +85,atrium > 40 ft height,0.53,0.53,0.53,0.53,W/ft2 +86,atrium >= 20 ft and <= 40 ft in height,0.53,0.53,0.53,0.53,W/ft2 +87,baggage/carousel,0.55,0.55,0.55,0.55,W/ft2 +88,"seating area, general",0.25,0.25,0.25,0.25,W/ft2 +89,transportation ticket counter,0.74,0.74,0.74,0.74,W/ft2 +90,warehouse - bulk storage,0.11,0.11,0.11,0.11,W/ft2 diff --git a/data/openstudio_standards_data/initial_data/level_2_lighting_space_types.csv b/data/openstudio_standards_data/initial_data/level_2_lighting_space_types.csv new file mode 100644 index 0000000000..c9adbd41c9 --- /dev/null +++ b/data/openstudio_standards_data/initial_data/level_2_lighting_space_types.csv @@ -0,0 +1,287 @@ +id,lighting_space_type_name,level_3_lighting_definition_table,level_3_lighting_defintion_id +1,bam_automotive_facility,level_3_lighting_90_1_2004,1 +2,bam_convention_center,level_3_lighting_90_1_2004,2 +3,bam_courthouse,level_3_lighting_90_1_2004,3 +4,bam_dinin_bar_lounge_leisure,level_3_lighting_90_1_2004,4 +5,bam_dining_cafeteria_fast_food,level_3_lighting_90_1_2004,5 +6,bam_dining_family,level_3_lighting_90_1_2004,6 +7,bam_dormitory,level_3_lighting_90_1_2004,7 +8,bam_exercise_center,level_3_lighting_90_1_2004,8 +9,bam_fire_station,level_3_lighting_90_1_2004,23 +10,bam_gymnasium,level_3_lighting_90_1_2004,9 +11,bam_healthcare_clinic,level_3_lighting_90_1_2004,10 +12,bam_hospital,level_3_lighting_90_1_2004,11 +13,bam_hotel,level_3_lighting_90_1_2004,12 +14,bam_library,level_3_lighting_90_1_2004,13 +15,bam_manufacturing_facility,level_3_lighting_90_1_2004,14 +16,bam_motel,level_3_lighting_90_1_2004,15 +17,bam_motion_picture_theater,level_3_lighting_90_1_2004,16 +18,bam_multifamily,level_3_lighting_90_1_2004,17 +19,bam_museum,level_3_lighting_90_1_2004,18 +20,bam_office,level_3_lighting_90_1_2004,19 +21,bam_parking_garage,level_3_lighting_90_1_2004,20 +22,bam_penitentiary,level_3_lighting_90_1_2004,21 +23,bam_performing_arts_theater,level_3_lighting_90_1_2004,22 +24,bam_police_station,level_3_lighting_90_1_2004,23 +25,bam_post_office,level_3_lighting_90_1_2004,24 +26,bam_religious_facility,level_3_lighting_90_1_2004,25 +27,bam_retail,level_3_lighting_90_1_2004,26 +28,bam_school_university,level_3_lighting_90_1_2004,27 +29,bam_sports_arena,level_3_lighting_90_1_2004,28 +30,bam_town_hall,level_3_lighting_90_1_2004,29 +31,bam_transportation,level_3_lighting_90_1_2004,30 +32,bam_warehouse,level_3_lighting_90_1_2004,31 +33,bam_workshop,level_3_lighting_90_1_2004,32 +34,office_enclosed_small,level_3_lighting_90_1_2004,33 +35,office_enclosed_large,level_3_lighting_90_1_2004,33 +36,office_open,level_3_lighting_90_1_2004,34 +37,conference_meeting_multipurpose,level_3_lighting_90_1_2004,35 +38,classroom_lecture_training_general,level_3_lighting_90_1_2004,36 +39,classroom_lecture_training_penitentiary,level_3_lighting_90_1_2004,37 +40,lobby_general,level_3_lighting_90_1_2004,38 +41,lobby_hotel,level_3_lighting_90_1_2004,39 +42,lobby_performing_arts_theater,level_3_lighting_90_1_2004,40 +43,lobby_motion_picture_theater,level_3_lighting_90_1_2004,41 +44,lobby_visually_impaired,level_3_lighting_90_1_2004,38 +45,lobby_elevator,level_3_lighting_90_1_2004,38 +46,audience_seating_general,level_3_lighting_90_1_2004,42 +47,audience_seating_gymnasium,level_3_lighting_90_1_2004,43 +48,audience_seating_exercise_center,level_3_lighting_90_1_2004,44 +49,audience_seating_convention_center,level_3_lighting_90_1_2004,45 +50,audience_seating_penitentiary,level_3_lighting_90_1_2004,46 +51,audience_seating_religious_facility,level_3_lighting_90_1_2004,47 +52,audience_seating_sports_arena,level_3_lighting_90_1_2004,48 +53,audience_seating_performing_arts_theater,level_3_lighting_90_1_2004,49 +54,audience_seating_motion_picture_theater,level_3_lighting_90_1_2004,50 +55,audience_seating_transportation,level_3_lighting_90_1_2004,51 +56,audience_seating_auditorium,level_3_lighting_90_1_2004,42 +57,atrium_first_three_floor,level_3_lighting_90_1_2004,52 +58,atrium_each_additional_floor,level_3_lighting_90_1_2004,53 +59,lounge_breakroom_general,level_3_lighting_90_1_2004,54 +60,lounge_breakroom_healthcare_facility,level_3_lighting_90_1_2004,55 +61,dining_general,level_3_lighting_90_1_2004,56 +62,dining_penitentiary,level_3_lighting_90_1_2004,57 +63,dining_hotel,level_3_lighting_90_1_2004,58 +64,dining_motel,level_3_lighting_90_1_2004,59 +65,dining_bar_lounge_leisure,level_3_lighting_90_1_2004,60 +66,dining_family,level_3_lighting_90_1_2004,61 +67,dining_cafeteria_fast_food,level_3_lighting_90_1_2004,56 +68,dining_visually_impaired,level_3_lighting_90_1_2004,56 +69,kitchen,level_3_lighting_90_1_2004,62 +70,laboratory_classroom,level_3_lighting_90_1_2004,63 +71,laboratory_all_other,level_3_lighting_90_1_2004,63 +72,restroom_visually_impaired,level_3_lighting_90_1_2004,64 +73,restroom_all_other,level_3_lighting_90_1_2004,64 +74,performing_arts_dressing_room,level_3_lighting_90_1_2004,65 +75,corridor_general,level_3_lighting_90_1_2004,66 +76,corridor_hospital,level_3_lighting_90_1_2004,67 +77,corridor_manufacturing_facility,level_3_lighting_90_1_2004,68 +78,corridor_visually_impaired,level_3_lighting_90_1_2004,66 +79,stairway,level_3_lighting_90_1_2004,69 +80,stairwell,level_3_lighting_90_1_2004,69 +81,storage_ all_other_small,level_3_lighting_90_1_2004,70 +82,storage_ all_other_large,level_3_lighting_90_1_2004,70 +83,storage_hospital_small,level_3_lighting_90_1_2004,71 +84,storage_hospital_large,level_3_lighting_90_1_2004,71 +85,storage_inactive,level_3_lighting_90_1_2004,72 +86,storage_inactive_museum,level_3_lighting_90_1_2004,73 +87,electrical_mechanical,level_3_lighting_90_1_2004,74 +88,workshop,level_3_lighting_90_1_2004,75 +89,gymnasium_playing_area,level_3_lighting_90_1_2004,76 +90,gymnasium_exercise_area,level_3_lighting_90_1_2004,77 +91,courtroom,level_3_lighting_90_1_2004,78 +92,confinement_cells,level_3_lighting_90_1_2004,79 +93,judges_chambers,level_3_lighting_90_1_2004,80 +94,emergency_vehicle_garage,level_3_lighting_90_1_2004,81 +95,firestation_sleeping_quarters,level_3_lighting_90_1_2004,82 +96,post_office_sorting_area,level_3_lighting_90_1_2004,83 +97,exhibit_convention_center,level_3_lighting_90_1_2004,84 +98,library_cataloging,level_3_lighting_90_1_2004,85 +99,library_stacks,level_3_lighting_90_1_2004,86 +100,library_reading,level_3_lighting_90_1_2004,87 +101,emergency_room,level_3_lighting_90_1_2004,88 +102,recovery,level_3_lighting_90_1_2004,89 +103,nurses_station,level_3_lighting_90_1_2004,90 +104,exam_treatment,level_3_lighting_90_1_2004,91 +105,pharmacy,level_3_lighting_90_1_2004,92 +106,patient_room,level_3_lighting_90_1_2004,93 +107,operating_room,level_3_lighting_90_1_2004,94 +108,nursery,level_3_lighting_90_1_2004,95 +109,medical_supply,level_3_lighting_90_1_2004,96 +110,physical_therapy,level_3_lighting_90_1_2004,97 +111,imaging,level_3_lighting_90_1_2004,98 +112,laundry_washing,level_3_lighting_90_1_2004,99 +113,automotive,level_3_lighting_90_1_2004,100 +114,manufacturing_low_bay,level_3_lighting_90_1_2004,101 +115,manufacturing_high_bay,level_3_lighting_90_1_2004,102 +116,detailed_manufacuring,level_3_lighting_90_1_2004,103 +117,manufacturing_equipment_room,level_3_lighting_90_1_2004,104 +118,manufacturing_control,level_3_lighting_90_1_2004,105 +119,guest_room,level_3_lighting_90_1_2004,106 +120,dormitory_living_quarters,level_3_lighting_90_1_2004,107 +121,museum_exhibit_area,level_3_lighting_90_1_2004,108 +122,museum_restoration,level_3_lighting_90_1_2004,109 +123,banking_activity,level_3_lighting_90_1_2004,110 +124,worship_pulpit_choir_area,level_3_lighting_90_1_2004,111 +125,fellowship_hall_religious_facility,level_3_lighting_90_1_2004,112 +126,sales,level_3_lighting_90_1_2004,113 +127,retail_mall_concourse,level_3_lighting_90_1_2004,114 +128,sports_arena_ring_sports_area,level_3_lighting_90_1_2004,115 +129,sports_arena_court_sports_area,level_3_lighting_90_1_2004,116 +130,sports_arena_indoor_playing_field,level_3_lighting_90_1_2004,117 +131,warehouse_bulk_storage,level_3_lighting_90_1_2004,119 +132,parking_area_interior,level_3_lighting_90_1_2004,120 +133,airport_concourse,level_3_lighting_90_1_2004,121 +134,baggage_carousel,level_3_lighting_90_1_2004,122 +135,transportation_ticket_counter,level_3_lighting_90_1_2004,123 +136,sales_display_type_1,level_3_lighting_90_1_2004,124 +137,sales_display_type_2,level_3_lighting_90_1_2004,124 +138,sales_display_type_3,level_3_lighting_90_1_2004,125 +139,sales_display_type_4,level_3_lighting_90_1_2004,125 +140,bam_automotive_facility,level_3_lighting_90_1_2019,1 +141,bam_convention_center,level_3_lighting_90_1_2019,2 +142,bam_courthouse,level_3_lighting_90_1_2019,3 +143,bam_dinin_bar_lounge_leisure,level_3_lighting_90_1_2019,4 +144,bam_dining_cafeteria_fast_food,level_3_lighting_90_1_2019,5 +145,bam_dining_family,level_3_lighting_90_1_2019,6 +146,bam_dormitory,level_3_lighting_90_1_2019,7 +147,bam_exercise_center,level_3_lighting_90_1_2019,8 +148,bam_fire_station,level_3_lighting_90_1_2019,9 +149,bam_gymnasium,level_3_lighting_90_1_2019,10 +150,bam_healthcare_clinic,level_3_lighting_90_1_2019,11 +151,bam_hospital,level_3_lighting_90_1_2019,12 +152,bam_hotel,level_3_lighting_90_1_2019,13 +153,bam_library,level_3_lighting_90_1_2019,14 +154,bam_manufacturing_facility,level_3_lighting_90_1_2019,15 +155,bam_motel,level_3_lighting_90_1_2019,13 +156,bam_motion_picture_theater,level_3_lighting_90_1_2019,16 +157,bam_multifamily,level_3_lighting_90_1_2019,17 +158,bam_museum,level_3_lighting_90_1_2019,18 +159,bam_office,level_3_lighting_90_1_2019,19 +160,bam_parking_garage,level_3_lighting_90_1_2019,20 +161,bam_penitentiary,level_3_lighting_90_1_2019,21 +162,bam_performing_arts_theater,level_3_lighting_90_1_2019,22 +163,bam_police_station,level_3_lighting_90_1_2019,23 +164,bam_post_office,level_3_lighting_90_1_2019,24 +165,bam_religious_facility,level_3_lighting_90_1_2019,25 +166,bam_retail,level_3_lighting_90_1_2019,26 +167,bam_school_university,level_3_lighting_90_1_2019,27 +168,bam_sports_arena,level_3_lighting_90_1_2019,28 +169,bam_town_hall,level_3_lighting_90_1_2019,29 +170,bam_transportation,level_3_lighting_90_1_2019,30 +171,bam_warehouse,level_3_lighting_90_1_2019,31 +172,bam_workshop,level_3_lighting_90_1_2019,32 +173,office_enclosed_small,level_3_lighting_90_1_2019,79 +174,office_enclosed_large,level_3_lighting_90_1_2019,80 +175,office_open,level_3_lighting_90_1_2019,81 +176,conference_meeting_multipurpose,level_3_lighting_90_1_2019,48 +177,classroom_lecture_training_general,level_3_lighting_90_1_2019,47 +178,classroom_lecture_training_penitentiary,level_3_lighting_90_1_2019,46 +179,lobby_general,level_3_lighting_90_1_2019,75 +180,lobby_hotel,level_3_lighting_90_1_2019,72 +181,lobby_performing_arts_theater,level_3_lighting_90_1_2019,74 +182,lobby_motion_picture_theater,level_3_lighting_90_1_2019,73 +183,lobby_visually_impaired,level_3_lighting_90_1_2019,70 +184,lobby_elevator,level_3_lighting_90_1_2019,71 +185,audience_seating_general,level_3_lighting_90_1_2019,43 +186,audience_seating_gymnasium,level_3_lighting_90_1_2019,37 +187,audience_seating_exercise_center,level_3_lighting_90_1_2019,43 +188,audience_seating_convention_center,level_3_lighting_90_1_2019,43 +189,audience_seating_penitentiary,level_3_lighting_90_1_2019,39 +190,audience_seating_religious_facility,level_3_lighting_90_1_2019,41 +191,audience_seating_sports_arena,level_3_lighting_90_1_2019,42 +192,audience_seating_performing_arts_theater,level_3_lighting_90_1_2019,40 +193,audience_seating_motion_picture_theater,level_3_lighting_90_1_2019,38 +194,audience_seating_transportation,level_3_lighting_90_1_2019,43 +195,audience_seating_auditorium,level_3_lighting_90_1_2019,36 +196,atrium_low,level_3_lighting_90_1_2019,33 +197,atrium_medium,level_3_lighting_90_1_2019,34 +198,atrium_high,level_3_lighting_90_1_2019,35 +199,lounge_breakroom_general,level_3_lighting_90_1_2019,78 +200,lounge_breakroom_healthcare_facility,level_3_lighting_90_1_2019,77 +201,dining_general,level_3_lighting_90_1_2019,61 +202,dining_penitentiary,level_3_lighting_90_1_2019,56 +203,dining_hotel,level_3_lighting_90_1_2019,61 +204,dining_motel,level_3_lighting_90_1_2019,61 +205,dining_bar_lounge_leisure,level_3_lighting_90_1_2019,58 +206,dining_family,level_3_lighting_90_1_2019,60 +207,dining_cafeteria_fast_food,level_3_lighting_90_1_2019,59 +208,dining_visually_impaired,level_3_lighting_90_1_2019,57 +209,kitchen,level_3_lighting_90_1_2019,64 +210,laboratory_classroom,level_3_lighting_90_1_2019,66 +211,laboratory_all_other,level_3_lighting_90_1_2019,67 +212,restroom_visually_impaired,level_3_lighting_90_1_2019,84 +213,restroom_all_other,level_3_lighting_90_1_2019,85 +214,performing_arts_dressing_room,level_3_lighting_90_1_2019,120 +215,corridor_general,level_3_lighting_90_1_2019,53 +216,corridor_hospital,level_3_lighting_90_1_2019,52 +217,corridor_manufacturing_facility,level_3_lighting_90_1_2019,53 +218,corridor_visually_impaired,level_3_lighting_90_1_2019,51 +219,stairway,level_3_lighting_90_1_2019,88 +220,stairwell,level_3_lighting_90_1_2019,89 +221,storage_ all_other_small,level_3_lighting_90_1_2019,90 +222,storage_ all_other_large,level_3_lighting_90_1_2019,91 +223,storage_hospital_small,level_3_lighting_90_1_2019,90 +224,storage_hospital_large,level_3_lighting_90_1_2019,91 +225,electrical_mechanical,level_3_lighting_90_1_2019,62 +226,workshop,level_3_lighting_90_1_2019,93 +227,gymnasium_playing_area,level_3_lighting_90_1_2019,101 +228,gymnasium_exercise_area,level_3_lighting_90_1_2019,100 +229,courtroom,level_3_lighting_90_1_2019,54 +230,confinement_cells,level_3_lighting_90_1_2019,49 +231,emergency_vehicle_garage,level_3_lighting_90_1_2019,63 +232,firestation_sleeping_quarters,level_3_lighting_90_1_2019,99 +233,post_office_sorting_area,level_3_lighting_90_1_2019,121 +234,exhibit_convention_center,level_3_lighting_90_1_2019,97 +235,library_stacks,level_3_lighting_90_1_2019,112 +236,library_reading,level_3_lighting_90_1_2019,111 +237,recovery,level_3_lighting_90_1_2019,110 +238,nurses_station,level_3_lighting_90_1_2019,106 +239,exam_treatment,level_3_lighting_90_1_2019,102 +240,pharmacy,level_3_lighting_90_1_2019,83 +241,patient_room,level_3_lighting_90_1_2019,108 +242,operating_room,level_3_lighting_90_1_2019,107 +243,nursery,level_3_lighting_90_1_2019,105 +244,medical_supply,level_3_lighting_90_1_2019,104 +245,physical_therapy,level_3_lighting_90_1_2019,109 +246,imaging,level_3_lighting_90_1_2019,103 +247,laundry_washing,level_3_lighting_90_1_2019,68 +248,automotive,level_3_lighting_90_1_2019,96 +249,manufacturing_low_bay,level_3_lighting_90_1_2019,117 +250,manufacturing_high_bay,level_3_lighting_90_1_2019,116 +251,detailed_manufacuring,level_3_lighting_90_1_2019,113 +252,manufacturing_equipment_room,level_3_lighting_90_1_2019,114 +253,manufacturing_extra_high_bay,level_3_lighting_90_1_2019,115 +254,guest_room,level_3_lighting_90_1_2019,65 +255,dormitory_living_quarters,level_3_lighting_90_1_2019,98 +256,museum_exhibit_area,level_3_lighting_90_1_2019,118 +257,museum_restoration,level_3_lighting_90_1_2019,119 +258,banking_activity,level_3_lighting_90_1_2019,44 +259,worship_pulpit_choir_area,level_3_lighting_90_1_2019,123 +260,fellowship_hall_religious_facility,level_3_lighting_90_1_2019,122 +261,sales,level_3_lighting_90_1_2019,86 +262,retail_mall_concourse,level_3_lighting_90_1_2019,125 +263,retail_dressing_room,level_3_lighting_90_1_2019,124 +264,sports_arena_playing_area_class_I,level_3_lighting_90_1_2019,126 +265,sports_arena_playing_area_class_II,level_3_lighting_90_1_2019,127 +266,sports_arena_playing_area_class_III,level_3_lighting_90_1_2019,128 +267,sports_arena_playing_area_class_IV,level_3_lighting_90_1_2019,129 +268,warehouse_fine_storage,level_3_lighting_90_1_2019,134 +269,warehouse_bulk_storage,level_3_lighting_90_1_2019,133 +270,parking_area_interior,level_3_lighting_90_1_2019,82 +271,airport_concourse,level_3_lighting_90_1_2019,131 +272,baggage_carousel,level_3_lighting_90_1_2019,130 +273,transportation_ticket_counter,level_3_lighting_90_1_2019,132 +274,sales_display_type_1,level_3_lighting_90_1_2019,135 +275,sales_display_type_2,level_3_lighting_90_1_2019,136 +276,sales_display_type_3,level_3_lighting_90_1_2019,137 +277,sales_display_type_4,level_3_lighting_90_1_2019,138 +278,breakroom,level_3_lighting_90_1_2019,45 +279,copy_print,level_3_lighting_90_1_2019,50 +280,computer_room,level_3_lighting_90_1_2019,55 +281,loading_dock,level_3_lighting_90_1_2019,69 +282,locker_room,level_3_lighting_90_1_2019,76 +283,seating_area_general,level_3_lighting_90_1_2019,87 +284,vehicular_maintenance,level_3_lighting_90_1_2019,92 +285,chapel_visually_impaired,level_3_lighting_90_1_2019,94 +286,recreation_common_living_visually_impaired,level_3_lighting_90_1_2019,95 diff --git a/data/openstudio_standards_data/initial_data/level_2_ventilation_space_types.csv b/data/openstudio_standards_data/initial_data/level_2_ventilation_space_types.csv new file mode 100644 index 0000000000..816a1d9cc9 --- /dev/null +++ b/data/openstudio_standards_data/initial_data/level_2_ventilation_space_types.csv @@ -0,0 +1,174 @@ +id,ventilation_space_type_name,level_3_ventilation_definition_table,level_3_ventilation_defintion_id +1,correctional_facilities_cell,level_3_ventilation_90_1_2019,13 +2,correctional_facilities_dayroom,level_3_ventilation_90_1_2019,14 +3,correctional_facilities_guard_stations,level_3_ventilation_90_1_2019,15 +4,correctional_facilities_booking_waiting,level_3_ventilation_90_1_2019,12 +5,educational_facilities_daycare,level_3_ventilation_90_1_2019,21 +6,educational_facilities_classroom_young,level_3_ventilation_90_1_2019,17 +7,educational_facilities_classroom_old,level_3_ventilation_90_1_2019,18 +8,educational_facilities_lecture_classroom,level_3_ventilation_90_1_2019,22 +9,educational_facilities_lecture_hall,level_3_ventilation_90_1_2019,23 +10,educational_facilities_art_classroom,level_3_ventilation_90_1_2019,16 +11,educational_facilities_science_laboratories,level_3_ventilation_90_1_2019,28 +12,educational_facilities_wood_metal_shop,level_3_ventilation_90_1_2019,30 +13,educational_facilities_computer_lab,level_3_ventilation_90_1_2019,19 +14,educational_facilities_media_center,level_3_ventilation_90_1_2019,25 +15,educational_facilities_music_theater_dance,level_3_ventilation_90_1_2019,27 +16,educational_facilities_multiuse_assembly,level_3_ventilation_90_1_2019,26 +17,educational_facilities_daycare_sickroom,level_3_ventilation_90_1_2019,20 +18,educational_facilities_libraries,level_3_ventilation_90_1_2019,24 +19,educational_facilities_university_college_laboratories,level_3_ventilation_90_1_2019,29 +20,food_beverage_service_restaurant_dining_rooms,level_3_ventilation_90_1_2019,34 +21,food_beverage_service_cafeteria_fast_food_dining,level_3_ventilation_90_1_2019,32 +22,food_beverage_service_bars_cocktail_lounges,level_3_ventilation_90_1_2019,31 +23,food_beverage_service_kitchen,level_3_ventilation_90_1_2019,33 +24,general_conference_meeting,level_3_ventilation_90_1_2019,37 +25,general_conference_corridors,level_3_ventilation_90_1_2019,38 +26,general_conference_storage_rooms,level_3_ventilation_90_1_2019,39 +27,general_break_rooms,level_3_ventilation_90_1_2019,35 +28,general_coffee_stations,level_3_ventilation_90_1_2019,36 +29,hotels_motels_resorts_dormitories_bedroom_living_room,level_3_ventilation_90_1_2019,41 +30,hotels_motels_resorts_dormitories_barracks_sleeping_areas,level_3_ventilation_90_1_2019,40 +31,hotels_motels_resorts_dormitories_lobbies_prefunction,level_3_ventilation_90_1_2019,44 +32,hotels_motels_resorts_dormitories_multi_purpose_assembly,level_3_ventilation_90_1_2019,45 +33,hotels_motels_resorts_dormitories_laundry_rooms,level_3_ventilation_90_1_2019,42 +34,hotels_motels_resorts_dormitories_laundry_rooms_w_dwelling_units,level_3_ventilation_90_1_2019,43 +35,office_buildings_office_space,level_3_ventilation_90_1_2019,62 +36,office_buildings_reception_areas,level_3_ventilation_90_1_2019,63 +37,office_buildings_telephone_data_entry,level_3_ventilation_90_1_2019,64 +38,office_buildings_main_entry_lobbies,level_3_ventilation_90_1_2019,60 +39,office_buildings_breakrooms,level_3_ventilation_90_1_2019,59 +40,office_buildings_occupiable_storage_rooms,level_3_ventilation_90_1_2019,61 +41,miscellaneous_spaces_bank_ vaults_safe_deposit,level_3_ventilation_90_1_2019,47 +42,miscellaneous_spaces_computer,level_3_ventilation_90_1_2019,48 +43,miscellaneous_spaces_pharmacy,level_3_ventilation_90_1_2019,52 +44,miscellaneous_spaces_photo_studios,level_3_ventilation_90_1_2019,53 +45,miscellaneous_spaces_shipping_receiving,level_3_ventilation_90_1_2019,54 +46,miscellaneous_spaces_transportation_waiting,level_3_ventilation_90_1_2019,57 +47,miscellaneous_spaces_warehouses,level_3_ventilation_90_1_2019,58 +48,miscellaneous_spaces_banks_bank_lobbies,level_3_ventilation_90_1_2019,46 +49,miscellaneous_spaces_freezer_refrigerated_spaces,level_3_ventilation_90_1_2019,49 +50,miscellaneous_spaces_manufacturing_wo_hazardous_materials,level_3_ventilation_90_1_2019,50 +51,miscellaneous_spaces_manufacturing_w_hazardous_materials,level_3_ventilation_90_1_2019,51 +52,miscellaneous_spaces_sorting_packing_light_assembly,level_3_ventilation_90_1_2019,55 +53,miscellaneous_spaces_telephone_closets,level_3_ventilation_90_1_2019,56 +54,public_assembly_spaces_auditorium_seating_area,level_3_ventilation_90_1_2019,83 +55,public_assembly_spaces_religious_workshop,level_3_ventilation_90_1_2019,90 +56,public_assembly_spaces_courtrooms,level_3_ventilation_90_1_2019,84 +57,public_assembly_spaces_legislative_chambers,level_3_ventilation_90_1_2019,85 +58,public_assembly_spaces_libraries,level_3_ventilation_90_1_2019,86 +59,public_assembly_spaces_lobbies,level_3_ventilation_90_1_2019,87 +60,public_assembly_spaces_children_museums,level_3_ventilation_90_1_2019,88 +61,public_assembly_spaces_museums_galleries,level_3_ventilation_90_1_2019,89 +62,retail_sales,level_3_ventilation_90_1_2019,91 +63,retail_mall_common_areas,level_3_ventilation_90_1_2019,95 +64,retail_barbershop,level_3_ventilation_90_1_2019,92 +65,retail_beauty_nail_salons,level_3_ventilation_90_1_2019,93 +66,retail_pet_shops,level_3_ventilation_90_1_2019,96 +67,retail_supermarket,level_3_ventilation_90_1_2019,97 +68,retail_coin_operated_laundries,level_3_ventilation_90_1_2019,94 +69,sports_entertainment_sports_arena,level_3_ventilation_90_1_2019,102 +70,sports_entertainment_gym_stadium,level_3_ventilation_90_1_2019,102 +71,sports_entertainment_spectator_areas,level_3_ventilation_90_1_2019,105 +72,sports_entertainment_swimming,level_3_ventilation_90_1_2019,107 +73,sports_entertainment_disco_dance_floors,level_3_ventilation_90_1_2019,99 +74,sports_entertainment_health_club_aerobics_room,level_3_ventilation_90_1_2019,103 +75,sports_entertainment_health_club_weight_rooms,level_3_ventilation_90_1_2019,104 +76,sports_entertainment_bowling_alley,level_3_ventilation_90_1_2019,98 +77,sports_entertainment_gambling_casinos,level_3_ventilation_90_1_2019,100 +78,sports_entertainment_game_arcades,level_3_ventilation_90_1_2019,101 +79,sports_entertainment_stages_studios,level_3_ventilation_90_1_2019,106 +80,animal_facilities_animal_exam_room,level_3_ventilation_90_1_2019,1 +81,animal_facilities_animal_imaging,level_3_ventilation_90_1_2019,2 +82,animal_facilities_animal_operating_rooms,level_3_ventilation_90_1_2019,3 +83,animal_facilities_animal_postoperative_recovery_room,level_3_ventilation_90_1_2019,4 +84,animal_facilities_animal_preparation_rooms,level_3_ventilation_90_1_2019,5 +85,animal_facilities_animal_procedure_room,level_3_ventilation_90_1_2019,6 +86,animal_facilities_animal_surgery_scrub,level_3_ventilation_90_1_2019,7 +87,animal_facilities_large_animal_holding_room,level_3_ventilation_90_1_2019,8 +88,animal_facilities_necropsy,level_3_ventilation_90_1_2019,9 +89,animal_facilities_small_animal_cage_room_static,level_3_ventilation_90_1_2019,10 +90,animal_facilities_small_animal_cage_room_ventilated,level_3_ventilation_90_1_2019,11 +91,outpatient_health_care_facilities_birthing_room,level_3_ventilation_90_1_2019,65 +92,outpatient_health_care_facilities_class_1_imaging_rooms,level_3_ventilation_90_1_2019,66 +93,outpatient_health_care_facilities_dental_operatory,level_3_ventilation_90_1_2019,67 +94,outpatient_health_care_facilities_general_examination_room,level_3_ventilation_90_1_2019,68 +95,outpatient_health_care_facilities_other_dental_treatment_areas,level_3_ventilation_90_1_2019,69 +96,outpatient_health_care_facilities_physical_therapy_exercise_area,level_3_ventilation_90_1_2019,70 +97,outpatient_health_care_facilities_physical_therapy_individual_room,level_3_ventilation_90_1_2019,71 +98,outpatient_health_care_facilities_physical_therapeutic_pool_area,level_3_ventilation_90_1_2019,72 +99,outpatient_health_care_facilities_prosthetics_orthotics_room,level_3_ventilation_90_1_2019,73 +100,outpatient_health_care_facilities_psychiatric_consultation_room,level_3_ventilation_90_1_2019,74 +101,outpatient_health_care_facilities_psychiatric_examination_room,level_3_ventilation_90_1_2019,75 +102,outpatient_health_care_facilities_psychiatric_group_room,level_3_ventilation_90_1_2019,76 +103,outpatient_health_care_facilities_psychiatric_seclusion_room,level_3_ventilation_90_1_2019,77 +104,outpatient_health_care_facilities_speech_therapy_room,level_3_ventilation_90_1_2019,78 +105,outpatient_health_care_facilities_urgent_care_examination_room,level_3_ventilation_90_1_2019,79 +106,outpatient_health_care_facilities_urgent_care_observation_room,level_3_ventilation_90_1_2019,80 +107,outpatient_health_care_facilities_urgent_care_treatment_room,level_3_ventilation_90_1_2019,81 +108,outpatient_health_care_facilities_urgent_care_triage_room,level_3_ventilation_90_1_2019,82 +109,transient_residential_common_corridors,level_3_ventilation_90_1_2019,108 +110,transient_residential_dwelling_unit,level_3_ventilation_90_1_2019,109 +111,correctional_facilities_cell,level_3_ventilation_90_1_2004,1 +112,correctional_facilities_dayroom,level_3_ventilation_90_1_2004,2 +113,correctional_facilities_guard_stations,level_3_ventilation_90_1_2004,3 +114,correctional_facilities_booking_waiting,level_3_ventilation_90_1_2004,4 +115,educational_facilities_daycare,level_3_ventilation_90_1_2004,5 +116,educational_facilities_classroom_young,level_3_ventilation_90_1_2004,6 +117,educational_facilities_classroom_old,level_3_ventilation_90_1_2004,7 +118,educational_facilities_lecture_classroom,level_3_ventilation_90_1_2004,8 +119,educational_facilities_lecture_hall,level_3_ventilation_90_1_2004,9 +120,educational_facilities_art_classroom,level_3_ventilation_90_1_2004,10 +121,educational_facilities_science_laboratories,level_3_ventilation_90_1_2004,11 +122,educational_facilities_wood_metal_shop,level_3_ventilation_90_1_2004,12 +123,educational_facilities_computer_lab,level_3_ventilation_90_1_2004,13 +124,educational_facilities_media_center,level_3_ventilation_90_1_2004,14 +125,educational_facilities_music_theater_dance,level_3_ventilation_90_1_2004,15 +126,educational_facilities_multiuse_assembly,level_3_ventilation_90_1_2004,16 +127,food_beverage_service_restaurant_dining_rooms,level_3_ventilation_90_1_2004,17 +128,food_beverage_service_cafeteria_fast_food_dining,level_3_ventilation_90_1_2004,18 +129,food_beverage_service_bars_cocktail_lounges,level_3_ventilation_90_1_2004,19 +130,general_conference_meeting,level_3_ventilation_90_1_2004,20 +131,general_conference_corridors,level_3_ventilation_90_1_2004,21 +132,general_conference_storage_rooms,level_3_ventilation_90_1_2004,22 +133,hotels_motels_resorts_dormitories_bedroom_living_room,level_3_ventilation_90_1_2004,23 +134,hotels_motels_resorts_dormitories_barracks_sleeping_areas,level_3_ventilation_90_1_2004,24 +135,hotels_motels_resorts_dormitories_lobbies_prefunction,level_3_ventilation_90_1_2004,25 +136,hotels_motels_resorts_dormitories_multi_purpose_assembly,level_3_ventilation_90_1_2004,26 +137,office_buildings_office_space,level_3_ventilation_90_1_2004,27 +138,office_buildings_reception_areas,level_3_ventilation_90_1_2004,28 +139,office_buildings_telephone_data_entry,level_3_ventilation_90_1_2004,29 +140,office_buildings_main_entry_lobbies,level_3_ventilation_90_1_2004,30 +141,miscellaneous_spaces_bank_ vaults_safe_deposit,level_3_ventilation_90_1_2004,31 +142,miscellaneous_spaces_computer,level_3_ventilation_90_1_2004,32 +143,miscellaneous_spaces_pharmacy,level_3_ventilation_90_1_2004,33 +144,miscellaneous_spaces_photo_studios,level_3_ventilation_90_1_2004,34 +145,miscellaneous_spaces_shipping_receiving,level_3_ventilation_90_1_2004,35 +146,miscellaneous_spaces_transportation_waiting,level_3_ventilation_90_1_2004,36 +147,miscellaneous_spaces_warehouses,level_3_ventilation_90_1_2004,37 +148,public_assembly_spaces_auditorium_seating_area,level_3_ventilation_90_1_2004,38 +149,public_assembly_spaces_religious_workshop,level_3_ventilation_90_1_2004,39 +150,public_assembly_spaces_courtrooms,level_3_ventilation_90_1_2004,40 +151,public_assembly_spaces_legislative_chambers,level_3_ventilation_90_1_2004,41 +152,public_assembly_spaces_libraries,level_3_ventilation_90_1_2004,42 +153,public_assembly_spaces_lobbies,level_3_ventilation_90_1_2004,43 +154,public_assembly_spaces_children_museums,level_3_ventilation_90_1_2004,44 +155,public_assembly_spaces_museums_galleries,level_3_ventilation_90_1_2004,45 +156,retail_sales,level_3_ventilation_90_1_2004,46 +157,retail_mall_common_areas,level_3_ventilation_90_1_2004,47 +158,retail_barbershop,level_3_ventilation_90_1_2004,48 +159,retail_beauty_nail_salons,level_3_ventilation_90_1_2004,49 +160,retail_pet_shops,level_3_ventilation_90_1_2004,50 +161,retail_supermarket,level_3_ventilation_90_1_2004,51 +162,retail_coin_operated_laundries,level_3_ventilation_90_1_2004,52 +163,sports_entertainment_sports_arena,level_3_ventilation_90_1_2004,53 +164,sports_entertainment_gym_stadium,level_3_ventilation_90_1_2004,54 +165,sports_entertainment_spectator_areas,level_3_ventilation_90_1_2004,55 +166,sports_entertainment_swimming,level_3_ventilation_90_1_2004,56 +167,sports_entertainment_disco_dance_floors,level_3_ventilation_90_1_2004,57 +168,sports_entertainment_health_club_aerobics_room,level_3_ventilation_90_1_2004,58 +169,sports_entertainment_health_club_weight_rooms,level_3_ventilation_90_1_2004,59 +170,sports_entertainment_bowling_alley,level_3_ventilation_90_1_2004,60 +171,sports_entertainment_gambling_casinos,level_3_ventilation_90_1_2004,61 +172,sports_entertainment_game_arcades,level_3_ventilation_90_1_2004,62 +173,sports_entertainment_stages_studios,level_3_ventilation_90_1_2004,63 diff --git a/data/openstudio_standards_data/initial_data/level_3_lighting_90_1_2004.csv b/data/openstudio_standards_data/initial_data/level_3_lighting_90_1_2004.csv new file mode 100644 index 0000000000..c970952f1c --- /dev/null +++ b/data/openstudio_standards_data/initial_data/level_3_lighting_90_1_2004.csv @@ -0,0 +1,126 @@ +id,method,lighting_primary_space_type,lighting_per_area,lighting_secondary_space_type,lighting_per_area_unit,annotation +1,BA,Automotive Facility,0.9,General,W/ft2, +2,BA,Convention Center,1.2,General,W/ft2, +3,BA,Court House,1.2,General,W/ft2, +4,BA,Dining: Bar Lounge/Leisure,1.3,General,W/ft2, +5,BA,Dining: Cafeteria/Fast Food,1.4,General,W/ft2, +6,BA,Dining: Family,1.6,General,W/ft2, +7,BA,Dormitory,1,General,W/ft2, +8,BA,Exercise Center,1,General,W/ft2, +9,BA,Gymnasium,1.1,General,W/ft2, +10,BA,Health Care-Clinic,1,General,W/ft2, +11,BA,Hospital,1.2,General,W/ft2, +12,BA,Hotel,1,General,W/ft2, +13,BA,Library,1.3,General,W/ft2, +14,BA,Manufacturing Facility,1.3,General,W/ft2, +15,BA,Motel,1,General,W/ft2, +16,BA,Motion Picture Theater,1.2,General,W/ft2, +17,BA,Multi-Family,0.7,General,W/ft2, +18,BA,Museum,1.1,General,W/ft2, +19,BA,Office,1,General,W/ft2, +20,BA,Parking Garage,0.3,General,W/ft2, +21,BA,Penitentiary,1,General,W/ft2, +22,BA,Performing Arts Theater,1.6,General,W/ft2, +23,BA,Police/Fire Station,1,General,W/ft2, +24,BA,Post Office,1.1,General,W/ft2, +25,BA,Religious Building,1.3,General,W/ft2, +26,BA,Retail,1.5,General,W/ft2, +27,BA,School/University,1.2,General,W/ft2, +28,BA,Sports Arena,1.1,General,W/ft2, +29,BA,Town Hall,1.1,General,W/ft2, +30,BA,Transportation,1,General,W/ft2, +31,BA,Warehouse,0.8,General,W/ft2, +32,BA,Workshop,1.4,General,W/ft2, +33,CS,Office-Enclosed,1.1,General,W/ft2, +34,CS,Office-Open Plan,1.1,General,W/ft2, +35,CS,Conference/Meeting/Multipurpose,1.3,General,W/ft2, +36,CS,Classroom/Lecture/Training,1.4,General,W/ft2, +37,CS,Classroom/Lecture/Training,1.3,For Penitentiary,W/ft2, +38,CS,Lobby,1.3,General,W/ft2, +39,CS,Lobby,1.1,For Hotel,W/ft2, +40,CS,Lobby,3.3,For Performing Arts Theater,W/ft2, +41,CS,Lobby,1.1,For Motion Picture Theater,W/ft2, +42,CS,Audience/Seating Area,0.9,General,W/ft2, +43,CS,Audience/Seating Area,0.4,For Gymnasium,W/ft2, +44,CS,Audience/Seating Area,0.3,For Exercise Center,W/ft2, +45,CS,Audience/Seating Area,0.7,For Convention Center,W/ft2, +46,CS,Audience/Seating Area,0.7,For Penitentiary,W/ft2, +47,CS,Audience/Seating Area,1.7,For Religious Buildings,W/ft2, +48,CS,Audience/Seating Area,0.4,For Sports Arena,W/ft2, +49,CS,Audience/Seating Area,2.6,For Performing Arts Theater,W/ft2, +50,CS,Audience/Seating Area,1.2,For Motion Picture Theater,W/ft2, +51,CS,Audience/Seating Area,0.5,For Transportation,W/ft2, +52,CS,Atrium: First Three Floors,0.6,General,W/ft2, +53,CS,Atrium: Each Additional Floor,0.2,General,W/ft2, +54,CS,Lounge/Recreation,1.2,General,W/ft2, +55,CS,Lounge/Recreation,0.8,For Hospital,W/ft2, +56,CS,Dining Area,0.9,General,W/ft2, +57,CS,Dining Area,1.3,For Penitentiary,W/ft2, +58,CS,Dining Area,1.3,For Hotel,W/ft2, +59,CS,Dining Area,1.2,For Motel,W/ft2, +60,CS,Dining Area,1.4,For Bar Lounge/Leisure Dining,W/ft2, +61,CS,Dining Area,2.1,For Family Dining,W/ft2, +62,CS,Food Preparation,1.2,General,W/ft2, +63,CS,Laboratory,1.4,General,W/ft2, +64,CS,Restrooms,0.9,General,W/ft2, +65,CS,Dressing/Locker/Fitting Room,0.6,General,W/ft2, +66,CS,Corridor/Transition,0.5,General,W/ft2, +67,CS,Corridor/Transition,1,For Hospital,W/ft2, +68,CS,Corridor/Transition,0.5,For Manufacturing Facility,W/ft2, +69,CS,Stairs: Active,0.6,General,W/ft2, +70,CS,Active Storage,0.8,General,W/ft2, +71,CS,Active Storage,0.9,For Hospital,W/ft2, +72,CS,Inactive Storage,0.3,General,W/ft2, +73,CS,Inactive Storage,0.8,For Museum,W/ft2, +74,CS,Electrical/Mechanical,1.5,General,W/ft2, +75,CS,Workshop,1.9,General,W/ft2, +76,SS,Gymnasium/Exercise Center,1.4,Playing Area,W/ft2, +77,SS,Gymnasium/Exercise Center,0.9,Exercise Area,W/ft2, +78,SS,Courthouse/Police Station/Penitentiary,1.9,Courtroom,W/ft2, +79,SS,Courthouse/Police Station/Penitentiary,0.9,Confinement Cells,W/ft2, +80,SS,Courthouse/Police Station/Penitentiary,1.3,Judges Chambers,W/ft2, +81,SS,Fire Stations,0.8,Fire Station Engine Room,W/ft2, +82,SS,Fire Stations,0.3,Sleeping Quarters,W/ft2, +83,SS,Post Office: Sorting Area,1.2,General,W/ft2, +84,SS,Convention Center: Exhibit Space,1.3,General,W/ft2, +85,SS,Library,1.1,Card File and Cataloging,W/ft2, +86,SS,Library,1.7,Stacks,W/ft2, +87,SS,Library,1.2,Reading Area,W/ft2, +88,SS,Hospital,2.7,Emergency,W/ft2, +89,SS,Hospital,0.8,Recovery,W/ft2, +90,SS,Hospital,1,Nurse Station,W/ft2, +91,SS,Hospital,1.5,Exam/Treatment,W/ft2, +92,SS,Hospital,1.2,Pharmacy,W/ft2, +93,SS,Hospital,0.7,Patient Room,W/ft2, +94,SS,Hospital,2.2,Operating Room,W/ft2, +95,SS,Hospital,0.6,Nursery,W/ft2, +96,SS,Hospital,1.4,Medical Supply,W/ft2, +97,SS,Hospital,0.9,Physical Therapy,W/ft2, +98,SS,Hospital,0.4,Radiology,W/ft2, +99,SS,Hospital,0.6,Laundry: Washing,W/ft2, +100,SS,Automotive: Service/Repair,0.7,General,W/ft2, +101,SS,Manufacturing,1.2,Low Bay (<25 ft Floor to Ceiling Height),W/ft2, +102,SS,Manufacturing,1.7,High Bay (>25 ft Floor to Ceiling Height),W/ft2, +103,SS,Manufacturing,2.1,Detailed Manufacturing,W/ft2, +104,SS,Manufacturing,1.2,Equipment Room,W/ft2, +105,SS,Manufacturing,0.5,Control Room,W/ft2, +106,SS,Hotel/Motel Guest Rooms,1.1,General,W/ft2, +107,SS,Dormitory: Living Quarters,1.1,General,W/ft2, +108,SS,Museum,1,General Exhibition,W/ft2, +109,SS,Museum,1.7,Restoration,W/ft2, +110,SS,Bank/Office: Banking Activity Area,1.5,General,W/ft2, +111,SS,Religious Buildings,2.4,"Worship Pulpit, Choir",W/ft2, +112,SS,Religious Buildings,0.9,Fellowship Hall,W/ft2, +113,SS,Retail,1.7,Sales Area,W/ft2, +114,SS,Retail,1.7,Mall Concourse,W/ft2, +115,SS,Sports Arena,2.7,Ring Sports Area,W/ft2, +116,SS,Sports Arena,2.3,Court Sports Area,W/ft2, +117,SS,Sports Arena,1.4,Indoor Playing Field Area,W/ft2, +118,SS,Warehouse,1.4,Fine Material Storage,W/ft2, +119,SS,Warehouse,0.9,Medium/Bulky Material Storage,W/ft2, +120,SS,Parking Garage: Garage Area,0.2,General,W/ft2, +121,SS,Transportation,0.6,Airport: Concourse,W/ft2, +122,SS,Transportation,1,Air/Train/Bus: Baggage Area,W/ft2, +123,SS,Transportation,1.5,Terminal: Ticket Counter,W/ft2, +124,SS,Retail,1.6,Sales Additional (Specific Display),W/ft2, +125,SS,Retail,3.9,Sales Additional (Valuable Merchandise),W/ft2, diff --git a/data/openstudio_standards_data/initial_data/level_3_lighting_90_1_2019.csv b/data/openstudio_standards_data/initial_data/level_3_lighting_90_1_2019.csv new file mode 100644 index 0000000000..fbc2b5ad09 --- /dev/null +++ b/data/openstudio_standards_data/initial_data/level_3_lighting_90_1_2019.csv @@ -0,0 +1,139 @@ +id,method,lighting_primary_space_type,lighting_per_area,lighting_secondary_space_type,lighting_per_area_unit,annotation +1,BA,Automotive facility,0.75,General,W/ft2, +2,BA,Convention center,0.64,General,W/ft2, +3,BA,Courthouse,0.79,General,W/ft2, +4,BA,Dining: Bar lounge/leisure,0.8,General,W/ft2, +5,BA,Dining: Cafeteria/fast food,0.76,General,W/ft2, +6,BA,Dining: Family,0.71,General,W/ft2, +7,BA,Dormitory,0.53,General,W/ft2, +8,BA,Exercise center,0.72,General,W/ft2, +9,BA,Fire station,0.56,General,W/ft2, +10,BA,Gymnasium,0.76,General,W/ft2, +11,BA,Health-care clinic,0.81,General,W/ft2, +12,BA,Hospital,0.96,General,W/ft2, +13,BA,Hotel/motel,0.56,General,W/ft2, +14,BA,Library,0.83,General,W/ft2, +15,BA,Manufacturing facility,0.82,General,W/ft2, +16,BA,Motion picture theater,0.44,General,W/ft2, +17,BA,Multifamily,0.45,General,W/ft2, +18,BA,Museum,0.55,General,W/ft2, +19,BA,Office,0.64,General,W/ft2, +20,BA,Parking garage,0.18,General,W/ft2, +21,BA,Penitentiary,0.69,General,W/ft2, +22,BA,Performing arts theater,0.84,General,W/ft2, +23,BA,Police station,0.66,General,W/ft2, +24,BA,Post office,0.65,General,W/ft2, +25,BA,Religious facility,0.67,General,W/ft2, +26,BA,Retail,0.84,General,W/ft2, +27,BA,School/university,0.72,General,W/ft2, +28,BA,Sports arena,0.76,General,W/ft2, +29,BA,Town hall,0.69,General,W/ft2, +30,BA,Transportation,0.5,General,W/ft2, +31,BA,Warehouse,0.45,General,W/ft2, +32,BA,Workshop,0.91,General,W/ft2, +33,CS,Atrium,0.39,< 20 ft in height,W/ft2, +34,CS,Atrium,0.48,>= 20 ft and <= 40 ft in height,W/ft2, +35,CS,Atrium,0.6,> 40 ft in height,W/ft2, +36,CS,Audience Seating Area,0.61,Auditorium,W/ft2, +37,CS,Audience Seating Area,0.23,Gymnasium,W/ft2, +38,CS,Audience Seating Area,0.27,Motion picture theater,W/ft2, +39,CS,Audience Seating Area,0.67,Penitentiary,W/ft2, +40,CS,Audience Seating Area,1.16,Performing arts theater,W/ft2, +41,CS,Audience Seating Area,0.72,Religious facility,W/ft2, +42,CS,Audience Seating Area,0.33,Sports arena,W/ft2, +43,CS,Audience Seating Area,0.23,All other audience seating areas,W/ft2, +44,CS,Banking Activity Area,0.61,General,W/ft2, +45,CS,Breakroom,0.59,General,W/ft2,(See Lounge/Breakroom) +46,CS,Classroom/Lecture Hall/Training Room,0.89,Penitentiary,W/ft2, +47,CS,Classroom/Lecture Hall/Training Room,0.71,All other classrooms/lecture halls/training rooms,W/ft2, +48,CS,Conference/Meeting/Multipurpose Room,0.97,General,W/ft2, +49,CS,Confinement Cells,0.7,General,W/ft2, +50,CS,Copy/Print Room,0.31,General,W/ft2, +51,CS,Corridor,0.71,Facility for the visually impaired (and not used primarily by the staff),W/ft2, +52,CS,Corridor,0.71,Hospital,W/ft2, +53,CS,Corridor,0.41,All other corridors,W/ft2, +54,CS,Courtroom,1.2,General,W/ft2, +55,CS,Computer Room,0.94,General,W/ft2, +56,CS,Dining Area,0.42,Penitentiary,W/ft2, +57,CS,Dining Area,1.27,Facility for the visually impaired (and not used primarily by staff),W/ft2, +58,CS,Dining Area,0.86,Bar/lounge or leisure dining,W/ft2, +59,CS,Dining Area,0.4,Cafeteria or fast food dining,W/ft2, +60,CS,Dining Area,0.6,Family dining,W/ft2, +61,CS,Dining Area,0.43,All other dining areas,W/ft2, +62,CS,Electrical/Mechanical Room,0.43,General,W/ft2, +63,CS,Emergency Vehicle Garage,0.52,General,W/ft2, +64,CS,Food Preparation Area,1.09,General,W/ft2, +65,CS,Guest Room,0.41,General,W/ft2, +66,CS,Laboratory,1.11,In or as a classroom,W/ft2, +67,CS,Laboratory,1.33,All other laboratories,W/ft2, +68,CS,Laundry/Washing Area,0.53,General,W/ft2, +69,CS,"Loading Dock, Interior",0.88,General,W/ft2, +70,CS,Lobby,1.69,Facility for the visually impaired (and not used primarily by the staff),W/ft2, +71,CS,Lobby,0.65,Elevator,W/ft2, +72,CS,Lobby,0.51,Hotel,W/ft2, +73,CS,Lobby,0.23,Motion picture theater,W/ft2, +74,CS,Lobby,1.25,Performing arts theater ,W/ft2, +75,CS,Lobby,0.84,All other lobbies,W/ft2, +76,CS,Locker Room,0.52,General,W/ft2, +77,CS,Lounge/Breakroom,0.42,Healthcare facility,W/ft2, +78,CS,Lounge/Breakroom,0.59,All other lounges/breakrooms,W/ft2, +79,CS,Office,0.74,Enclosed and <= 250 ft2,W/ft2, +80,CS,Office,0.66,Enclosed and > 250 ft2,W/ft2, +81,CS,Office,0.61,Open plan,W/ft2, +82,CS,"Parking Area, Interior",0.15,General,W/ft2, +83,CS,Pharmacy Area,1.66,General,W/ft2, +84,CS,Restroom,1.26,Facility for the visually impaired (and not used primarily by the staff),W/ft2, +85,CS,Restroom,0.63,All other restrooms,W/ft2, +86,CS,Sales Area,1.05,General,W/ft2, +87,CS,"Seating Area, General",0.23,General,W/ft2, +88,CS,Stairway,0.49,General,W/ft2,The space containing the stairway shall determine the LPD and control requirements for the stairway. +89,CS,Stairwell,0.49,General,W/ft2, +90,CS,Storage Room,0.51,< 50 ft2,W/ft2, +91,CS,Storage Room,0.38,>= 50 ft2,W/ft2, +92,CS,Vehicular Maintenance Area,0.6,General,W/ft2, +93,CS,Workshop,1.26,General,W/ft2, +94,SS,Facility for the Visually Impaired,0.7,Chapel (used primarily by residents),W/ft2, +95,SS,Facility for the Visually Impaired,1.77,Recreation room/common living room (and not used primarily by staff),W/ft2, +96,SS,Automotive,0.6,General,W/ft2,(See 'Vehicular Maintenance Area') +97,SS,Convention Center: Exhibit Space,0.61,General,W/ft2, +98,SS,Dormitory: Living Quarters,0.5,General,W/ft2, +99,SS,Fire Station: Sleeping Quarters,0.23,General,W/ft2, +100,SS,Gymnasium/Fitness Center,0.9,Exercise area,W/ft2, +101,SS,Gymnasium/Fitness Center,0.85,Playing area,W/ft2, +102,SS,Healthcare Facility,1.4,Exam/treatment room,W/ft2, +103,SS,Healthcare Facility,0.94,Imaging room,W/ft2, +104,SS,Healthcare Facility,0.62,Medical supply room,W/ft2, +105,SS,Healthcare Facility,0.92,Nursery,W/ft2, +106,SS,Healthcare Facility,1.17,Nurse's station,W/ft2, +107,SS,Healthcare Facility,2.26,Operating room,W/ft2, +108,SS,Healthcare Facility,0.68,Patient room,W/ft2, +109,SS,Healthcare Facility,0.91,Physical therapy room,W/ft2, +110,SS,Healthcare Facility,1.25,Recovery room,W/ft2, +111,SS,Library,0.96,Reading area,W/ft2, +112,SS,Library,1.18,Stacks,W/ft2, +113,SS,Manufacturing Facility,0.8,Detailed manufacturing area,W/ft2, +114,SS,Manufacturing Facility,0.76,Equipment room,W/ft2, +115,SS,Manufacturing Facility,1.42,Extra high bay area (> 50 ft floor-to-ceiling height),W/ft2, +116,SS,Manufacturing Facility,1.24,High bay area (25 to 50 ft floor-to-ceiling height),W/ft2, +117,SS,Manufacturing Facility,0.86,Low bay area (< 25 ft floor-to-ceiling height),W/ft2, +118,SS,Museum,0.31,General exhibition area,W/ft2, +119,SS,Museum,1.1,Restoration room,W/ft2, +120,SS,Performing Arts Theater: Dressing Room,0.41,General,W/ft2, +121,SS,Post Office: Sorting Area,0.76,General,W/ft2, +122,SS,Religious Facility,0.54,Fellowship hall,W/ft2, +123,SS,Religious Facility,0.85,Worship/pulpit/choir area,W/ft2, +124,SS,Retail Facilities,0.51,Dressing/fitting room,W/ft2, +125,SS,Retail Facilities,0.82,Mall concourse,W/ft2, +126,SS,Sports Arena: Playing Area,2.94,Class I facility,W/ft2, +127,SS,Sports Arena: Playing Area,2.01,Class II facility,W/ft2, +128,SS,Sports Arena: Playing Area,1.3,Class III facility,W/ft2, +129,SS,Sports Arena: Playing Area,0.86,Class IV facility,W/ft2, +130,SS,Transportation Facility,0.39,Baggage/carousel area,W/ft2, +131,SS,Transportation Facility,0.25,Airport concourse,W/ft2, +132,SS,Transportation Facility,0.51,Ticket counter,W/ft2, +133,SS,Warehouse: Storage Area,0.33,"Medium to bulky, palletized items",W/ft2, +134,SS,Warehouse: Storage Area,0.69,"Smaller, hand-carried items",W/ft2, +135,SS,Retail,0.45,Sales Additional (Retail Area 1),W/ft2, +136,SS,Retail,0.45,Sales Additional (Retail Area 2),W/ft2, +137,SS,Retail,1.05,Sales Additional (Retail Area 3),W/ft2, +138,SS,Retail,1.88,Sales Additional (Retail Area 4),W/ft2, diff --git a/data/openstudio_standards_data/initial_data/level_3_ventilation_62_1_2004.csv b/data/openstudio_standards_data/initial_data/level_3_ventilation_62_1_2004.csv new file mode 100644 index 0000000000..90bd0aa856 --- /dev/null +++ b/data/openstudio_standards_data/initial_data/level_3_ventilation_62_1_2004.csv @@ -0,0 +1,64 @@ +id,ventilation_primary_space_type,ventilation_secondary_space_type,ventilation_per_person,ventilation_per_person_unit,ventilation_per_area,ventilation_per_area_unit,occupancy_per_area,occupancy_per_area_unit,air_class,os,annotation +1,Correctional Facilities,Cell,5,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, +2,Correctional Facilities,Day room,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, +3,Correctional Facilities,Guard stations,5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,, +4,Correctional Facilities,Booking/waiting,7.5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,2,, +5,Educational Facilities,Daycare (through age 4),10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, +6,Educational Facilities,Classrooms (ages 5-8),10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, +7,Educational Facilities,Classrooms (age 9 plus),10,cfm/person,0.12,cfm/ft2,35,ppl/1000 ft2,1,, +8,Educational Facilities,Lecture classroom,7.5,cfm/person,0.06,cfm/ft2,65,ppl/1000 ft2,1,, +9,Educational Facilities,Lecture hall (fixed seats),7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, +10,Educational Facilities,Art classroom,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, +11,Educational Facilities,Science laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,,, +12,Educational Facilities,Wood/metal shop,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, +13,Educational Facilities,Computer lab,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, +14,Educational Facilities,Media center,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, +15,Educational Facilities,Music/theater/dance,10,cfm/person,0.06,cfm/ft2,35,ppl/1000 ft2,1,, +16,Educational Facilities,Multi-use assembly,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, +17,Food and Beverage Service,Restaurant dining rooms,7.5,cfm/person,0.18,cfm/ft2,70,ppl/1000 ft2,2,, +18,Food and Beverage Service,Cafeteria/fast food dining,7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, +19,Food and Beverage Service,"Bars, cocktail lounges",7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, +20,General,Conference/meeting,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, +21,General,Corridors,,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,1,, +22,General,Storage rooms,,cfm/person,0.12,cfm/ft2,,ppl/1000 ft2,1,, +23,"Hotels, Motels, Resorts, Dormitories",Bedroom/living Room,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,, +24,"Hotels, Motels, Resorts, Dormitories",Barracks sleeping areas,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, +25,"Hotels, Motels, Resorts, Dormitories",Lobbies/prefunction,7.5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, +26,"Hotels, Motels, Resorts, Dormitories",Multi-purpose assembly,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,, +27,Office Buildings,Office space,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1,, +28,Office Buildings,Reception areas,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, +29,Office Buildings,Telephone/data entry,5,cfm/person,0.06,cfm/ft2,60,ppl/1000 ft2,1,, +30,Office Buildings,Main entry lobbies,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,, +31,Miscellaneous Spaces,Bank vaults/safe deposit,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,2,, +32,Miscellaneous Spaces,Computer (not printing),5,cfm/person,0.06,cfm/ft2,4,ppl/1000 ft2,1,, +33,Miscellaneous Spaces,Pharmacy (prep. area),5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, +34,Miscellaneous Spaces,Photo studios,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, +35,Miscellaneous Spaces,Shipping/receiving,,cfm/person,0.12,cfm/ft2,,ppl/1000 ft2,1,, +36,Miscellaneous Spaces,Transportation waiting,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, +37,Miscellaneous Spaces,Warehouses,,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,2,, +38,Public Assembly Spaces,Auditorium seating area,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, +39,Public Assembly Spaces,Places of religious workshop,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,, +40,Public Assembly Spaces,Courtrooms,5,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, +41,Public Assembly Spaces,Legislative chambers,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, +42,Public Assembly Spaces,Libraries,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, +43,Public Assembly Spaces,Lobbies,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, +44,Public Assembly Spaces,Museums (children's),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, +45,Public Assembly Spaces,Museums/galleries,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, +46,Retail,Sales (except as below),7.5,cfm/person,0.12,cfm/ft2,15,ppl/1000 ft2,2,, +47,Retail,Mall common areas,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, +48,Retail,Barber shop,7.5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,2,, +49,Retail,Beauty and nail salons,20,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, +50,Retail,Pet shops (animal areas),7.5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, +51,Retail,Supermarket,7.5,cfm/person,0.06,cfm/ft2,8,ppl/1000 ft2,1,, +52,Retail,Coin-operated laundries,7.5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,2,, +53,Sports and Entertainment,Sports arena (play area),,cfm/person,0.3,cfm/ft2,,ppl/1000 ft2,1,, +54,Sports and Entertainment,"Gym, stadium (play area)",,cfm/person,0.3,cfm/ft2,30,ppl/1000 ft2,2,, +55,Sports and Entertainment,Spectator areas,7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, +56,Sports and Entertainment,Swimming (pool & deck),,cfm/person,0.48,cfm/ft2,,ppl/1000 ft2,2,, +57,Sports and Entertainment,Disco/dance floors,20,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, +58,Sports and Entertainment,Health club/aerobics room,20,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,2,, +59,Sports and Entertainment,Health club/weight rooms,20,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,2,, +60,Sports and Entertainment,Bowling alley (seating),10,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, +61,Sports and Entertainment,Gambling casinos,7.5,cfm/person,0.18,cfm/ft2,120,ppl/1000 ft2,1,, +62,Sports and Entertainment,Game arcades,7.5,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, +63,Sports and Entertainment,"Stages, studios",10,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, diff --git a/data/openstudio_standards_data/initial_data/level_3_ventilation_62_1_2019.csv b/data/openstudio_standards_data/initial_data/level_3_ventilation_62_1_2019.csv new file mode 100644 index 0000000000..0ebaf45414 --- /dev/null +++ b/data/openstudio_standards_data/initial_data/level_3_ventilation_62_1_2019.csv @@ -0,0 +1,110 @@ +id,ventilation_primary_space_type,ventilation_secondary_space_type,ventilation_per_person,ventilation_per_person_unit,ventilation_per_area,ventilation_per_area_unit,occupancy_per_area,occupancy_per_area_unit,air_class,os,annotation +1,Animal Facilities,Animal exam room (veterinary office),10,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2,, +2,Animal Facilities,Animal imaging (MRI/CT/PET),10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, +3,Animal Facilities,Animal operating rooms,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, +4,Animal Facilities,Animal postoperative recovery room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, +5,Animal Facilities,Animal preparation rooms,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, +6,Animal Facilities,Animal procedure room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, +7,Animal Facilities,Animal surgery scrub,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, +8,Animal Facilities,Large-animal holding room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, +9,Animal Facilities,Necropsy,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, +10,Animal Facilities,Small-animal-cage room (static cages),10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, +11,Animal Facilities,Small-animal-cage room (ventilated cages),10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, +12,Correctional Facilities,Booking/waiting,7.5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,2,, +13,Correctional Facilities,Cell,5,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, +14,Correctional Facilities,Dayroom,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, +15,Correctional Facilities,Guard stations,5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,, +16,Educational Facilities,Art classroom,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, +17,Educational Facilities,Classrooms (ages 5 to 8),10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, +18,Educational Facilities,Classrooms (age 9 plus),10,cfm/person,0.12,cfm/ft2,35,ppl/1000 ft2,1,, +19,Educational Facilities,Computer lab,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, +20,Educational Facilities,Daycare sickroom,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,3,, +21,Educational Facilities,Daycare (through age 4),10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, +22,Educational Facilities,Lecture classroom,7.5,cfm/person,0.06,cfm/ft2,65,ppl/1000 ft2,1,yes, +23,Educational Facilities,Lecture hall (fixed seats),7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,yes, +24,Educational Facilities,Libraries (education),5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,,, +25,Educational Facilities,Media center,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, +26,Educational Facilities,Multiuse assembly,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,yes, +27,Educational Facilities,Music/theater/dance,10,cfm/person,0.06,cfm/ft2,35,ppl/1000 ft2,1,yes, +28,Educational Facilities,Science laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, +29,Educational Facilities,University/college laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, +30,Educational Facilities,Wood/metal shop,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, +31,Food and Beverage Service,"Bars, cocktail lounges",7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, +32,Food and Beverage Service,Cafeteria/fast-food dining,7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, +33,Food and Beverage Service,Kitchen (cooking),7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2,, +34,Food and Beverage Service,Restaurant dining rooms,7.5,cfm/person,0.18,cfm/ft2,70,ppl/1000 ft2,2,, +35,"Food and Beverage Service, General",Break rooms,5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,1,yes, +36,"Food and Beverage Service, General",Coffee stations,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,yes, +37,"Food and Beverage Service, General",Conference/meeting,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,yes, +38,"Food and Beverage Service, General",Corridors,,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,1,yes, +39,"Food and Beverage Service, General",Occupiable storage rooms for liquids or gels,5,cfm/person,0.12,cfm/ft2,2,ppl/1000 ft2,2,, +40,"Hotels, Motels, Resorts, Dormitories",Barracks sleeping areas,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,yes, +41,"Hotels, Motels, Resorts, Dormitories",Bedroom/living room,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,yes, +42,"Hotels, Motels, Resorts, Dormitories","Laundry rooms, central",5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,2,, +43,"Hotels, Motels, Resorts, Dormitories",Laundry rooms within dwelling units,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, +44,"Hotels, Motels, Resorts, Dormitories",Lobbies/prefunction,7.5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,yes, +45,"Hotels, Motels, Resorts, Dormitories",Multipurpose assembly,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,yes, +46,Miscellaneous Spaces,Banks or bank lobbies,7.5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,yes, +47,Miscellaneous Spaces,Bank vaults/safe deposit,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,2,yes, +48,Miscellaneous Spaces,Computer (not printing),5,cfm/person,0.06,cfm/ft2,4,ppl/1000 ft2,1,yes, +49,Miscellaneous Spaces,Freezer and refrigerated spaces (<50�F [10�C]),10,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,2,, +50,Miscellaneous Spaces,Manufacturing where hazardous materials are not used,10,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,2,, +51,Miscellaneous Spaces,Manufacturing where hazardous materials are used (excludes heavy industrial and chemical processes),10,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,3,, +52,Miscellaneous Spaces,Pharmacy (prep. area),5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, +53,Miscellaneous Spaces,Photo studios,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, +54,Miscellaneous Spaces,Shipping/receiving,10,cfm/person,0.12,cfm/ft2,2,ppl/1000 ft2,2,, +55,Miscellaneous Spaces,"Sorting, packing, light assembly",7.5,cfm/person,0.12,cfm/ft2,7,ppl/1000 ft2,2,, +56,Miscellaneous Spaces,Telephone closets,,cfm/person,0,cfm/ft2,,ppl/1000 ft2,1,, +57,Miscellaneous Spaces,Transportation waiting,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,yes, +58,Miscellaneous Spaces,Warehouses,10,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,2,, +59,Office Buildings,Breakrooms,5,cfm/person,0.12,cfm/ft2,50,ppl/1000 ft2,1,, +60,Office Buildings,Main entry lobbies,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,yes, +61,Office Buildings,Occupiable storage rooms for dry materials,5,cfm/person,0.06,cfm/ft2,2,ppl/1000 ft2,1,, +62,Office Buildings,Office space,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1,yes, +63,Office Buildings,Reception areas,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,yes, +64,Office Buildings,Telephone/data entry,5,cfm/person,0.06,cfm/ft2,60,ppl/1000 ft2,1,yes, +65,Outpatient Health Care Facilities,Birthing room,10,cfm/person,0.18,cfm/ft2,15,ppl/1000 ft2,2,, +66,Outpatient Health Care Facilities,Class 1 imaging rooms,5,cfm/person,0.12,cfm/ft2,5,ppl/1000 ft2,1,, +67,Outpatient Health Care Facilities,Dental operatory,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, +68,Outpatient Health Care Facilities,General examination room,7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,1,, +69,Outpatient Health Care Facilities,Other dental treatment areas,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1,, +70,Outpatient Health Care Facilities,Physical therapy exercise area,20,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,2,, +71,Outpatient Health Care Facilities,Physical therapy individual room,10,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, +72,Outpatient Health Care Facilities,Physical therapeutic pool area,,cfm/person,0.48,cfm/ft2,,ppl/1000 ft2,2,, +73,Outpatient Health Care Facilities,Prosthetics and orthotics room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, +74,Outpatient Health Care Facilities,Psychiatric consultation room,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, +75,Outpatient Health Care Facilities,Psychiatric examination room,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, +76,Outpatient Health Care Facilities,Psychiatric group room,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, +77,Outpatient Health Care Facilities,Psychiatric seclusion room,10,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1,, +78,Outpatient Health Care Facilities,Speech therapy room,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, +79,Outpatient Health Care Facilities,Urgent care examination room,7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,1,, +80,Outpatient Health Care Facilities,Urgent care observation room,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, +81,Outpatient Health Care Facilities,Urgent care treatment room,7.5,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, +82,Outpatient Health Care Facilities,Urgent care triage room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, +83,Public Assembly Spaces,Auditorium seating area,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,yes, +84,Public Assembly Spaces,Courtrooms,5,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,yes, +85,Public Assembly Spaces,Legislative chambers,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,yes, +86,Public Assembly Spaces,Libraries (public assembly),5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, +87,Public Assembly Spaces,Lobbies,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,yes, +88,Public Assembly Spaces,Museums (children's),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, +89,Public Assembly Spaces,Museums/galleries,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,yes, +90,Public Assembly Spaces,Places of religious worship,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,yes, +91,Retail,Sales (except as below),7.5,cfm/person,0.12,cfm/ft2,15,ppl/1000 ft2,2,, +92,Retail,Barbershop,7.5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,2,yes, +93,Retail,Beauty and nail salons,20,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, +94,Retail,Coin-operated laundries,7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2,, +95,Retail,Mall common areas,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,yes, +96,Retail,Pet shops (animal areas),7.5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, +97,Retail,Supermarket,7.5,cfm/person,0.06,cfm/ft2,8,ppl/1000 ft2,1,yes, +98,Sports and Entertainment,Bowling alley (seating),10,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, +99,Sports and Entertainment,Disco/dance floors,20,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,2,yes, +100,Sports and Entertainment,Gambling casinos,7.5,cfm/person,0.18,cfm/ft2,120,ppl/1000 ft2,1,, +101,Sports and Entertainment,Game arcades,7.5,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, +102,Sports and Entertainment,"Gym, sports arena (play area)",20,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,2,, +103,Sports and Entertainment,Health club/aerobics room,20,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,2,, +104,Sports and Entertainment,Health club/weight rooms,20,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,2,, +105,Sports and Entertainment,Spectator areas,7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,yes, +106,Sports and Entertainment,"Stages, studios",10,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,yes, +107,Sports and Entertainment,Swimming (pool and deck),,cfm/person,0.48,cfm/ft2,,ppl/1000 ft2,2,, +108,Transient Residential,Common corridors,,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,1,yes, +109,Transient Residential,Dwelling unit,5,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,1,yes, diff --git a/data/openstudio_standards_data/initial_data/light_def_90_1_2004.json b/data/openstudio_standards_data/initial_data/light_def_90_1_2004.json new file mode 100644 index 0000000000..6530823f03 --- /dev/null +++ b/data/openstudio_standards_data/initial_data/light_def_90_1_2004.json @@ -0,0 +1,1127 @@ +[ + { + "id": 1, + "method": "BA", + "lighting_primary_space_type": "Automotive Facility", + "lighting_per_area": 0.9, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 2, + "method": "BA", + "lighting_primary_space_type": "Convention Center", + "lighting_per_area": 1.2, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 3, + "method": "BA", + "lighting_primary_space_type": "Court House", + "lighting_per_area": 1.2, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 4, + "method": "BA", + "lighting_primary_space_type": "Dining: Bar Lounge/Leisure", + "lighting_per_area": 1.3, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 5, + "method": "BA", + "lighting_primary_space_type": "Dining: Cafeteria/Fast Food", + "lighting_per_area": 1.4, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 6, + "method": "BA", + "lighting_primary_space_type": "Dining: Family", + "lighting_per_area": 1.6, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 7, + "method": "BA", + "lighting_primary_space_type": "Dormitory", + "lighting_per_area": 1, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 8, + "method": "BA", + "lighting_primary_space_type": "Exercise Center", + "lighting_per_area": 1, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 9, + "method": "BA", + "lighting_primary_space_type": "Gymnasium", + "lighting_per_area": 1.1, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 10, + "method": "BA", + "lighting_primary_space_type": "Health Care-Clinic", + "lighting_per_area": 1, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 11, + "method": "BA", + "lighting_primary_space_type": "Hospital", + "lighting_per_area": 1.2, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 12, + "method": "BA", + "lighting_primary_space_type": "Hotel", + "lighting_per_area": 1, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 13, + "method": "BA", + "lighting_primary_space_type": "Library", + "lighting_per_area": 1.3, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 14, + "method": "BA", + "lighting_primary_space_type": "Manufacturing Facility", + "lighting_per_area": 1.3, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 15, + "method": "BA", + "lighting_primary_space_type": "Motel", + "lighting_per_area": 1, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 16, + "method": "BA", + "lighting_primary_space_type": "Motion Picture Theater", + "lighting_per_area": 1.2, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 17, + "method": "BA", + "lighting_primary_space_type": "Multi-Family", + "lighting_per_area": 0.7, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 18, + "method": "BA", + "lighting_primary_space_type": "Museum", + "lighting_per_area": 1.1, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 19, + "method": "BA", + "lighting_primary_space_type": "Office", + "lighting_per_area": 1, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 20, + "method": "BA", + "lighting_primary_space_type": "Parking Garage", + "lighting_per_area": 0.3, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 21, + "method": "BA", + "lighting_primary_space_type": "Penitentiary", + "lighting_per_area": 1, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 22, + "method": "BA", + "lighting_primary_space_type": "Performing Arts Theater", + "lighting_per_area": 1.6, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 23, + "method": "BA", + "lighting_primary_space_type": "Police/Fire Station", + "lighting_per_area": 1, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 24, + "method": "BA", + "lighting_primary_space_type": "Post Office", + "lighting_per_area": 1.1, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 25, + "method": "BA", + "lighting_primary_space_type": "Religious Building", + "lighting_per_area": 1.3, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 26, + "method": "BA", + "lighting_primary_space_type": "Retail", + "lighting_per_area": 1.5, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 27, + "method": "BA", + "lighting_primary_space_type": "School/University", + "lighting_per_area": 1.2, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 28, + "method": "BA", + "lighting_primary_space_type": "Sports Arena", + "lighting_per_area": 1.1, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 29, + "method": "BA", + "lighting_primary_space_type": "Town Hall", + "lighting_per_area": 1.1, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 30, + "method": "BA", + "lighting_primary_space_type": "Transportation", + "lighting_per_area": 1, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 31, + "method": "BA", + "lighting_primary_space_type": "Warehouse", + "lighting_per_area": 0.8, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 32, + "method": "BA", + "lighting_primary_space_type": "Workshop", + "lighting_per_area": 1.4, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 33, + "method": "CS", + "lighting_primary_space_type": "Office-Enclosed", + "lighting_per_area": 1.1, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 34, + "method": "CS", + "lighting_primary_space_type": "Office-Open Plan", + "lighting_per_area": 1.1, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 35, + "method": "CS", + "lighting_primary_space_type": "Conference/Meeting/Multipurpose", + "lighting_per_area": 1.3, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 36, + "method": "CS", + "lighting_primary_space_type": "Classroom/Lecture/Training", + "lighting_per_area": 1.4, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 37, + "method": "CS", + "lighting_primary_space_type": "Classroom/Lecture/Training", + "lighting_per_area": 1.3, + "lighting_secondary_space_type": "For Penitentiary", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 38, + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_per_area": 1.3, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 39, + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_per_area": 1.1, + "lighting_secondary_space_type": "For Hotel", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 40, + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_per_area": 3.3, + "lighting_secondary_space_type": "For Performing Arts Theater", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 41, + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_per_area": 1.1, + "lighting_secondary_space_type": "For Motion Picture Theater", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 42, + "method": "CS", + "lighting_primary_space_type": "Audience/Seating Area", + "lighting_per_area": 0.9, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 43, + "method": "CS", + "lighting_primary_space_type": "Audience/Seating Area", + "lighting_per_area": 0.4, + "lighting_secondary_space_type": "For Gymnasium", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 44, + "method": "CS", + "lighting_primary_space_type": "Audience/Seating Area", + "lighting_per_area": 0.3, + "lighting_secondary_space_type": "For Exercise Center", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 45, + "method": "CS", + "lighting_primary_space_type": "Audience/Seating Area", + "lighting_per_area": 0.7, + "lighting_secondary_space_type": "For Convention Center", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 46, + "method": "CS", + "lighting_primary_space_type": "Audience/Seating Area", + "lighting_per_area": 0.7, + "lighting_secondary_space_type": "For Penitentiary", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 47, + "method": "CS", + "lighting_primary_space_type": "Audience/Seating Area", + "lighting_per_area": 1.7, + "lighting_secondary_space_type": "For Religious Buildings", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 48, + "method": "CS", + "lighting_primary_space_type": "Audience/Seating Area", + "lighting_per_area": 0.4, + "lighting_secondary_space_type": "For Sports Arena", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 49, + "method": "CS", + "lighting_primary_space_type": "Audience/Seating Area", + "lighting_per_area": 2.6, + "lighting_secondary_space_type": "For Performing Arts Theater", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 50, + "method": "CS", + "lighting_primary_space_type": "Audience/Seating Area", + "lighting_per_area": 1.2, + "lighting_secondary_space_type": "For Motion Picture Theater", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 51, + "method": "CS", + "lighting_primary_space_type": "Audience/Seating Area", + "lighting_per_area": 0.5, + "lighting_secondary_space_type": "For Transportation", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 52, + "method": "CS", + "lighting_primary_space_type": "Atrium\u00ef\u00bf\u00bdFirst Three Floors", + "lighting_per_area": 0.6, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 53, + "method": "CS", + "lighting_primary_space_type": "Atrium\u00ef\u00bf\u00bdEach Additional Floor", + "lighting_per_area": 0.2, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 54, + "method": "CS", + "lighting_primary_space_type": "Lounge/Recreation", + "lighting_per_area": 1.2, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 55, + "method": "CS", + "lighting_primary_space_type": "Lounge/Recreation", + "lighting_per_area": 0.8, + "lighting_secondary_space_type": "For Hospital", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 56, + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_per_area": 0.9, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 57, + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_per_area": 1.3, + "lighting_secondary_space_type": "For Penitentiary", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 58, + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_per_area": 1.3, + "lighting_secondary_space_type": "For Hotel", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 59, + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_per_area": 1.2, + "lighting_secondary_space_type": "For Motel", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 60, + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_per_area": 1.4, + "lighting_secondary_space_type": "For Bar Lounge/Leisure Dining", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 61, + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_per_area": 2.1, + "lighting_secondary_space_type": "For Family Dining", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 62, + "method": "CS", + "lighting_primary_space_type": "Food Preparation", + "lighting_per_area": 1.2, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 63, + "method": "CS", + "lighting_primary_space_type": "Laboratory", + "lighting_per_area": 1.4, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 64, + "method": "CS", + "lighting_primary_space_type": "Restrooms", + "lighting_per_area": 0.9, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 65, + "method": "CS", + "lighting_primary_space_type": "Dressing/Locker/Fitting Room", + "lighting_per_area": 0.6, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 66, + "method": "CS", + "lighting_primary_space_type": "Corridor/Transition", + "lighting_per_area": 0.5, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 67, + "method": "CS", + "lighting_primary_space_type": "Corridor/Transition", + "lighting_per_area": 1, + "lighting_secondary_space_type": "For Hospital", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 68, + "method": "CS", + "lighting_primary_space_type": "Corridor/Transition", + "lighting_per_area": 0.5, + "lighting_secondary_space_type": "For Manufacturing Facility", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 69, + "method": "CS", + "lighting_primary_space_type": "Stairs\u00ef\u00bf\u00bdActive", + "lighting_per_area": 0.6, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 70, + "method": "CS", + "lighting_primary_space_type": "Active Storage", + "lighting_per_area": 0.8, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 71, + "method": "CS", + "lighting_primary_space_type": "Active Storage", + "lighting_per_area": 0.9, + "lighting_secondary_space_type": "For Hospital", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 72, + "method": "CS", + "lighting_primary_space_type": "Inactive Storage", + "lighting_per_area": 0.3, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 73, + "method": "CS", + "lighting_primary_space_type": "Inactive Storage", + "lighting_per_area": 0.8, + "lighting_secondary_space_type": "For Museum", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 74, + "method": "CS", + "lighting_primary_space_type": "Electrical/Mechanical", + "lighting_per_area": 1.5, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 75, + "method": "CS", + "lighting_primary_space_type": "Workshop", + "lighting_per_area": 1.9, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 76, + "method": "SS", + "lighting_primary_space_type": "Gymnasium/Exercise Center", + "lighting_per_area": 1.4, + "lighting_secondary_space_type": "Playing Area", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 77, + "method": "SS", + "lighting_primary_space_type": "Gymnasium/Exercise Center", + "lighting_per_area": 0.9, + "lighting_secondary_space_type": "Exercise Area", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 78, + "method": "SS", + "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", + "lighting_per_area": 1.9, + "lighting_secondary_space_type": "Courtroom", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 79, + "method": "SS", + "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", + "lighting_per_area": 0.9, + "lighting_secondary_space_type": "Confinement Cells", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 80, + "method": "SS", + "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", + "lighting_per_area": 1.3, + "lighting_secondary_space_type": "Judges Chambers", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 81, + "method": "SS", + "lighting_primary_space_type": "Fire Stations", + "lighting_per_area": 0.8, + "lighting_secondary_space_type": "Fire Station Engine Room", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 82, + "method": "SS", + "lighting_primary_space_type": "Fire Stations", + "lighting_per_area": 0.3, + "lighting_secondary_space_type": "Sleeping Quarters", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 83, + "method": "SS", + "lighting_primary_space_type": "Post Office\u00ef\u00bf\u00bdSorting Area", + "lighting_per_area": 1.2, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 84, + "method": "SS", + "lighting_primary_space_type": "Convention Center\u00ef\u00bf\u00bdExhibit Space", + "lighting_per_area": 1.3, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 85, + "method": "SS", + "lighting_primary_space_type": "Library", + "lighting_per_area": 1.1, + "lighting_secondary_space_type": "Card File and Cataloging", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 86, + "method": "SS", + "lighting_primary_space_type": "Library", + "lighting_per_area": 1.7, + "lighting_secondary_space_type": "Stacks", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 87, + "method": "SS", + "lighting_primary_space_type": "Library", + "lighting_per_area": 1.2, + "lighting_secondary_space_type": "Reading Area", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 88, + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_per_area": 2.7, + "lighting_secondary_space_type": "Emergency", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 89, + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_per_area": 0.8, + "lighting_secondary_space_type": "Recovery", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 90, + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_per_area": 1, + "lighting_secondary_space_type": "Nurse Station", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 91, + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_per_area": 1.5, + "lighting_secondary_space_type": "Exam/Treatment", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 92, + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_per_area": 1.2, + "lighting_secondary_space_type": "Pharmacy", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 93, + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_per_area": 0.7, + "lighting_secondary_space_type": "Patient Room", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 94, + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_per_area": 2.2, + "lighting_secondary_space_type": "Operating Room", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 95, + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_per_area": 0.6, + "lighting_secondary_space_type": "Nursery", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 96, + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_per_area": 1.4, + "lighting_secondary_space_type": "Medical Supply", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 97, + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_per_area": 0.9, + "lighting_secondary_space_type": "Physical Therapy", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 98, + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_per_area": 0.4, + "lighting_secondary_space_type": "Radiology", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 99, + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_per_area": 0.6, + "lighting_secondary_space_type": "Laundry\u00ef\u00bf\u00bdWashing", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 100, + "method": "SS", + "lighting_primary_space_type": "Automotive\u00ef\u00bf\u00bdService/Repair", + "lighting_per_area": 0.7, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 101, + "method": "SS", + "lighting_primary_space_type": "Manufacturing", + "lighting_per_area": 1.2, + "lighting_secondary_space_type": "Low Bay (<25 ft Floor to Ceiling Height)", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 102, + "method": "SS", + "lighting_primary_space_type": "Manufacturing", + "lighting_per_area": 1.7, + "lighting_secondary_space_type": "High Bay (>25 ft Floor to Ceiling Height)", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 103, + "method": "SS", + "lighting_primary_space_type": "Manufacturing", + "lighting_per_area": 2.1, + "lighting_secondary_space_type": "Detailed Manufacturing", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 104, + "method": "SS", + "lighting_primary_space_type": "Manufacturing", + "lighting_per_area": 1.2, + "lighting_secondary_space_type": "Equipment Room", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 105, + "method": "SS", + "lighting_primary_space_type": "Manufacturing", + "lighting_per_area": 0.5, + "lighting_secondary_space_type": "Control Room", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 106, + "method": "SS", + "lighting_primary_space_type": "Hotel/Motel Guest Rooms", + "lighting_per_area": 1.1, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 107, + "method": "SS", + "lighting_primary_space_type": "Dormitory\u00ef\u00bf\u00bdLiving Quarters", + "lighting_per_area": 1.1, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 108, + "method": "SS", + "lighting_primary_space_type": "Museum", + "lighting_per_area": 1, + "lighting_secondary_space_type": "General Exhibition", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 109, + "method": "SS", + "lighting_primary_space_type": "Museum", + "lighting_per_area": 1.7, + "lighting_secondary_space_type": "Restoration", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 110, + "method": "SS", + "lighting_primary_space_type": "Bank/Office\u00ef\u00bf\u00bdBanking Activity Area", + "lighting_per_area": 1.5, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 111, + "method": "SS", + "lighting_primary_space_type": "Religious Buildings", + "lighting_per_area": 2.4, + "lighting_secondary_space_type": "Worship Pulpit, Choir", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 112, + "method": "SS", + "lighting_primary_space_type": "Religious Buildings", + "lighting_per_area": 0.9, + "lighting_secondary_space_type": "Fellowship Hall", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 113, + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_per_area": 1.7, + "lighting_secondary_space_type": "Sales Area", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 114, + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_per_area": 1.7, + "lighting_secondary_space_type": "Mall Concourse", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 115, + "method": "SS", + "lighting_primary_space_type": "Sports Arena", + "lighting_per_area": 2.7, + "lighting_secondary_space_type": "Ring Sports Area", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 116, + "method": "SS", + "lighting_primary_space_type": "Sports Arena", + "lighting_per_area": 2.3, + "lighting_secondary_space_type": "Court Sports Area", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 117, + "method": "SS", + "lighting_primary_space_type": "Sports Arena", + "lighting_per_area": 1.4, + "lighting_secondary_space_type": "Indoor Playing Field Area", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 118, + "method": "SS", + "lighting_primary_space_type": "Warehouse", + "lighting_per_area": 1.4, + "lighting_secondary_space_type": "Fine Material Storage", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 119, + "method": "SS", + "lighting_primary_space_type": "Warehouse", + "lighting_per_area": 0.9, + "lighting_secondary_space_type": "Medium/Bulky Material Storage", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 120, + "method": "SS", + "lighting_primary_space_type": "Parking Garage\u00ef\u00bf\u00bdGarage Area", + "lighting_per_area": 0.2, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 121, + "method": "SS", + "lighting_primary_space_type": "Transportation", + "lighting_per_area": 0.6, + "lighting_secondary_space_type": "Airport\u00ef\u00bf\u00bdConcourse", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 122, + "method": "SS", + "lighting_primary_space_type": "Transportation", + "lighting_per_area": 1, + "lighting_secondary_space_type": "Air/Train/Bus\u00ef\u00bf\u00bdBaggage Area", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 123, + "method": "SS", + "lighting_primary_space_type": "Transportation", + "lighting_per_area": 1.5, + "lighting_secondary_space_type": "Terminal\u00ef\u00bf\u00bdTicket Counter", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 124, + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_per_area": 1.6, + "lighting_secondary_space_type": "Sales Additional (Specific Display)", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 125, + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_per_area": 3.9, + "lighting_secondary_space_type": "Sales Additional (Valuable Merchandise)", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/initial_data/light_def_90_1_2019.json b/data/openstudio_standards_data/initial_data/light_def_90_1_2019.json new file mode 100644 index 0000000000..343a0a7a43 --- /dev/null +++ b/data/openstudio_standards_data/initial_data/light_def_90_1_2019.json @@ -0,0 +1,1244 @@ +[ + { + "id": 1, + "method": "BA", + "lighting_primary_space_type": "Automotive facility", + "lighting_per_area": 0.75, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 2, + "method": "BA", + "lighting_primary_space_type": "Convention center", + "lighting_per_area": 0.64, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 3, + "method": "BA", + "lighting_primary_space_type": "Courthouse", + "lighting_per_area": 0.79, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 4, + "method": "BA", + "lighting_primary_space_type": "Dining: Bar lounge/leisure", + "lighting_per_area": 0.8, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 5, + "method": "BA", + "lighting_primary_space_type": "Dining: Cafeteria/fast food", + "lighting_per_area": 0.76, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 6, + "method": "BA", + "lighting_primary_space_type": "Dining: Family", + "lighting_per_area": 0.71, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 7, + "method": "BA", + "lighting_primary_space_type": "Dormitory", + "lighting_per_area": 0.53, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 8, + "method": "BA", + "lighting_primary_space_type": "Exercise center", + "lighting_per_area": 0.72, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 9, + "method": "BA", + "lighting_primary_space_type": "Fire station", + "lighting_per_area": 0.56, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 10, + "method": "BA", + "lighting_primary_space_type": "Gymnasium", + "lighting_per_area": 0.76, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 11, + "method": "BA", + "lighting_primary_space_type": "Health-care clinic", + "lighting_per_area": 0.81, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 12, + "method": "BA", + "lighting_primary_space_type": "Hospital", + "lighting_per_area": 0.96, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 13, + "method": "BA", + "lighting_primary_space_type": "Hotel/motel", + "lighting_per_area": 0.56, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 14, + "method": "BA", + "lighting_primary_space_type": "Library", + "lighting_per_area": 0.83, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 15, + "method": "BA", + "lighting_primary_space_type": "Manufacturing facility", + "lighting_per_area": 0.82, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 16, + "method": "BA", + "lighting_primary_space_type": "Motion picture theater", + "lighting_per_area": 0.44, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 17, + "method": "BA", + "lighting_primary_space_type": "Multifamily", + "lighting_per_area": 0.45, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 18, + "method": "BA", + "lighting_primary_space_type": "Museum", + "lighting_per_area": 0.55, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 19, + "method": "BA", + "lighting_primary_space_type": "Office", + "lighting_per_area": 0.64, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 20, + "method": "BA", + "lighting_primary_space_type": "Parking garage", + "lighting_per_area": 0.18, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 21, + "method": "BA", + "lighting_primary_space_type": "Penitentiary", + "lighting_per_area": 0.69, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 22, + "method": "BA", + "lighting_primary_space_type": "Performing arts theater", + "lighting_per_area": 0.84, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 23, + "method": "BA", + "lighting_primary_space_type": "Police station", + "lighting_per_area": 0.66, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 24, + "method": "BA", + "lighting_primary_space_type": "Post office", + "lighting_per_area": 0.65, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 25, + "method": "BA", + "lighting_primary_space_type": "Religious facility", + "lighting_per_area": 0.67, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 26, + "method": "BA", + "lighting_primary_space_type": "Retail", + "lighting_per_area": 0.84, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 27, + "method": "BA", + "lighting_primary_space_type": "School/university", + "lighting_per_area": 0.72, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 28, + "method": "BA", + "lighting_primary_space_type": "Sports arena", + "lighting_per_area": 0.76, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 29, + "method": "BA", + "lighting_primary_space_type": "Town hall", + "lighting_per_area": 0.69, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 30, + "method": "BA", + "lighting_primary_space_type": "Transportation", + "lighting_per_area": 0.5, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 31, + "method": "BA", + "lighting_primary_space_type": "Warehouse", + "lighting_per_area": 0.45, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 32, + "method": "BA", + "lighting_primary_space_type": "Workshop", + "lighting_per_area": 0.91, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 33, + "method": "CS", + "lighting_primary_space_type": "Atrium", + "lighting_per_area": 0.39, + "lighting_secondary_space_type": "< 20 ft in height", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 34, + "method": "CS", + "lighting_primary_space_type": "Atrium", + "lighting_per_area": 0.48, + "lighting_secondary_space_type": ">= 20 ft and <= 40 ft in height", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 35, + "method": "CS", + "lighting_primary_space_type": "Atrium", + "lighting_per_area": 0.6, + "lighting_secondary_space_type": "> 40 ft in height", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 36, + "method": "CS", + "lighting_primary_space_type": "Audience Seating Area", + "lighting_per_area": 0.61, + "lighting_secondary_space_type": "Auditorium", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 37, + "method": "CS", + "lighting_primary_space_type": "Audience Seating Area", + "lighting_per_area": 0.23, + "lighting_secondary_space_type": "Gymnasium", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 38, + "method": "CS", + "lighting_primary_space_type": "Audience Seating Area", + "lighting_per_area": 0.27, + "lighting_secondary_space_type": "Motion picture theater", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 39, + "method": "CS", + "lighting_primary_space_type": "Audience Seating Area", + "lighting_per_area": 0.67, + "lighting_secondary_space_type": "Penitentiary", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 40, + "method": "CS", + "lighting_primary_space_type": "Audience Seating Area", + "lighting_per_area": 1.16, + "lighting_secondary_space_type": "Performing arts theater", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 41, + "method": "CS", + "lighting_primary_space_type": "Audience Seating Area", + "lighting_per_area": 0.72, + "lighting_secondary_space_type": "Religious facility", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 42, + "method": "CS", + "lighting_primary_space_type": "Audience Seating Area", + "lighting_per_area": 0.33, + "lighting_secondary_space_type": "Sports arena", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 43, + "method": "CS", + "lighting_primary_space_type": "Audience Seating Area", + "lighting_per_area": 0.23, + "lighting_secondary_space_type": "All other audience seating areas", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 44, + "method": "CS", + "lighting_primary_space_type": "Banking Activity Area", + "lighting_per_area": 0.61, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 45, + "method": "CS", + "lighting_primary_space_type": "Breakroom", + "lighting_per_area": 0.59, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "(See Lounge/Breakroom)" + }, + { + "id": 46, + "method": "CS", + "lighting_primary_space_type": "Classroom/Lecture Hall/Training Room", + "lighting_per_area": 0.89, + "lighting_secondary_space_type": "Penitentiary", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 47, + "method": "CS", + "lighting_primary_space_type": "Classroom/Lecture Hall/Training Room", + "lighting_per_area": 0.71, + "lighting_secondary_space_type": "All other classrooms/lecture halls/training rooms", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 48, + "method": "CS", + "lighting_primary_space_type": "Conference/Meeting/Multipurpose Room", + "lighting_per_area": 0.97, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 49, + "method": "CS", + "lighting_primary_space_type": "Confinement Cells", + "lighting_per_area": 0.7, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 50, + "method": "CS", + "lighting_primary_space_type": "Copy/Print Room", + "lighting_per_area": 0.31, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 51, + "method": "CS", + "lighting_primary_space_type": "Corridor", + "lighting_per_area": 0.71, + "lighting_secondary_space_type": "Facility for the visually impaired (and not used primarily by the staff)", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 52, + "method": "CS", + "lighting_primary_space_type": "Corridor", + "lighting_per_area": 0.71, + "lighting_secondary_space_type": "Hospital", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 53, + "method": "CS", + "lighting_primary_space_type": "Corridor", + "lighting_per_area": 0.41, + "lighting_secondary_space_type": "All other corridors", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 54, + "method": "CS", + "lighting_primary_space_type": "Courtroom", + "lighting_per_area": 1.2, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 55, + "method": "CS", + "lighting_primary_space_type": "Computer Room", + "lighting_per_area": 0.94, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 56, + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_per_area": 0.42, + "lighting_secondary_space_type": "Penitentiary", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 57, + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_per_area": 1.27, + "lighting_secondary_space_type": "Facility for the visually impaired (and not used primarily by staff)", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 58, + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_per_area": 0.86, + "lighting_secondary_space_type": "Bar/lounge or leisure dining", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 59, + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_per_area": 0.4, + "lighting_secondary_space_type": "Cafeteria or fast food dining", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 60, + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_per_area": 0.6, + "lighting_secondary_space_type": "Family dining", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 61, + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_per_area": 0.43, + "lighting_secondary_space_type": "All other dining areas", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 62, + "method": "CS", + "lighting_primary_space_type": "Electrical/Mechanical Room", + "lighting_per_area": 0.43, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 63, + "method": "CS", + "lighting_primary_space_type": "Emergency Vehicle Garage", + "lighting_per_area": 0.52, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 64, + "method": "CS", + "lighting_primary_space_type": "Food Preparation Area", + "lighting_per_area": 1.09, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 65, + "method": "CS", + "lighting_primary_space_type": "Guest Room", + "lighting_per_area": 0.41, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 66, + "method": "CS", + "lighting_primary_space_type": "Laboratory", + "lighting_per_area": 1.11, + "lighting_secondary_space_type": "In or as a classroom", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 67, + "method": "CS", + "lighting_primary_space_type": "Laboratory", + "lighting_per_area": 1.33, + "lighting_secondary_space_type": "All other laboratories", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 68, + "method": "CS", + "lighting_primary_space_type": "Laundry/Washing Area", + "lighting_per_area": 0.53, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 69, + "method": "CS", + "lighting_primary_space_type": "Loading Dock, Interior", + "lighting_per_area": 0.88, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 70, + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_per_area": 1.69, + "lighting_secondary_space_type": "Facility for the visually impaired (and not used primarily by the staff)", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 71, + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_per_area": 0.65, + "lighting_secondary_space_type": "Elevator", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 72, + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_per_area": 0.51, + "lighting_secondary_space_type": "Hotel", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 73, + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_per_area": 0.23, + "lighting_secondary_space_type": "Motion picture theater", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 74, + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_per_area": 1.25, + "lighting_secondary_space_type": "Performing arts theater ", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 75, + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_per_area": 0.84, + "lighting_secondary_space_type": "All other lobbies", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 76, + "method": "CS", + "lighting_primary_space_type": "Locker Room", + "lighting_per_area": 0.52, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 77, + "method": "CS", + "lighting_primary_space_type": "Lounge/Breakroom", + "lighting_per_area": 0.42, + "lighting_secondary_space_type": "Healthcare facility", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 78, + "method": "CS", + "lighting_primary_space_type": "Lounge/Breakroom", + "lighting_per_area": 0.59, + "lighting_secondary_space_type": "All other lounges/breakrooms", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 79, + "method": "CS", + "lighting_primary_space_type": "Office", + "lighting_per_area": 0.74, + "lighting_secondary_space_type": "Enclosed and <= 250 ft2", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 80, + "method": "CS", + "lighting_primary_space_type": "Office", + "lighting_per_area": 0.66, + "lighting_secondary_space_type": "Enclosed and > 250 ft2", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 81, + "method": "CS", + "lighting_primary_space_type": "Office", + "lighting_per_area": 0.61, + "lighting_secondary_space_type": "Open plan", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 82, + "method": "CS", + "lighting_primary_space_type": "Parking Area, Interior", + "lighting_per_area": 0.15, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 83, + "method": "CS", + "lighting_primary_space_type": "Pharmacy Area", + "lighting_per_area": 1.66, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 84, + "method": "CS", + "lighting_primary_space_type": "Restroom", + "lighting_per_area": 1.26, + "lighting_secondary_space_type": "Facility for the visually impaired (and not used primarily by the staff)", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 85, + "method": "CS", + "lighting_primary_space_type": "Restroom", + "lighting_per_area": 0.63, + "lighting_secondary_space_type": "All other restrooms", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 86, + "method": "CS", + "lighting_primary_space_type": "Sales Area", + "lighting_per_area": 1.05, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 87, + "method": "CS", + "lighting_primary_space_type": "Seating Area, General", + "lighting_per_area": 0.23, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 88, + "method": "CS", + "lighting_primary_space_type": "Stairway", + "lighting_per_area": 0.49, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "The space containing the stairway shall determine the LPD and control requirements for the stairway." + }, + { + "id": 89, + "method": "CS", + "lighting_primary_space_type": "Stairwell", + "lighting_per_area": 0.49, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 90, + "method": "CS", + "lighting_primary_space_type": "Storage Room", + "lighting_per_area": 0.51, + "lighting_secondary_space_type": "< 50 ft2", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 91, + "method": "CS", + "lighting_primary_space_type": "Storage Room", + "lighting_per_area": 0.38, + "lighting_secondary_space_type": ">= 50 ft2", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 92, + "method": "CS", + "lighting_primary_space_type": "Vehicular Maintenance Area", + "lighting_per_area": 0.6, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 93, + "method": "CS", + "lighting_primary_space_type": "Workshop", + "lighting_per_area": 1.26, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 94, + "method": "SS", + "lighting_primary_space_type": "Facility for the Visually Impaired", + "lighting_per_area": 0.7, + "lighting_secondary_space_type": "Chapel (used primarily by residents)", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 95, + "method": "SS", + "lighting_primary_space_type": "Facility for the Visually Impaired", + "lighting_per_area": 1.77, + "lighting_secondary_space_type": "Recreation room/common living room (and not used primarily by staff)", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 96, + "method": "SS", + "lighting_primary_space_type": "Automotive", + "lighting_per_area": 0.6, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "(See \u201cVehicular Maintenance Area\u201d)" + }, + { + "id": 97, + "method": "SS", + "lighting_primary_space_type": "Convention Center\u2014Exhibit Space", + "lighting_per_area": 0.61, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 98, + "method": "SS", + "lighting_primary_space_type": "Dormitory\u2014Living Quarters", + "lighting_per_area": 0.5, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 99, + "method": "SS", + "lighting_primary_space_type": "Fire Station\u2014Sleeping Quarters", + "lighting_per_area": 0.23, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 100, + "method": "SS", + "lighting_primary_space_type": "Gymnasium/Fitness Center", + "lighting_per_area": 0.9, + "lighting_secondary_space_type": "Exercise area", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 101, + "method": "SS", + "lighting_primary_space_type": "Gymnasium/Fitness Center", + "lighting_per_area": 0.85, + "lighting_secondary_space_type": "Playing area", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 102, + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_per_area": 1.4, + "lighting_secondary_space_type": "Exam/treatment room", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 103, + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_per_area": 0.94, + "lighting_secondary_space_type": "Imaging room", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 104, + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_per_area": 0.62, + "lighting_secondary_space_type": "Medical supply room", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 105, + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_per_area": 0.92, + "lighting_secondary_space_type": "Nursery", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 106, + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_per_area": 1.17, + "lighting_secondary_space_type": "Nurse\u2019s station", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 107, + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_per_area": 2.26, + "lighting_secondary_space_type": "Operating room", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 108, + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_per_area": 0.68, + "lighting_secondary_space_type": "Patient room", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 109, + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_per_area": 0.91, + "lighting_secondary_space_type": "Physical therapy room", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 110, + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_per_area": 1.25, + "lighting_secondary_space_type": "Recovery room", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 111, + "method": "SS", + "lighting_primary_space_type": "Library", + "lighting_per_area": 0.96, + "lighting_secondary_space_type": "Reading area", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 112, + "method": "SS", + "lighting_primary_space_type": "Library", + "lighting_per_area": 1.18, + "lighting_secondary_space_type": "Stacks", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 113, + "method": "SS", + "lighting_primary_space_type": "Manufacturing Facility", + "lighting_per_area": 0.8, + "lighting_secondary_space_type": "Detailed manufacturing area", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 114, + "method": "SS", + "lighting_primary_space_type": "Manufacturing Facility", + "lighting_per_area": 0.76, + "lighting_secondary_space_type": "Equipment room", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 115, + "method": "SS", + "lighting_primary_space_type": "Manufacturing Facility", + "lighting_per_area": 1.42, + "lighting_secondary_space_type": "Extra high bay area (> 50 ft floor-to-ceiling height)", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 116, + "method": "SS", + "lighting_primary_space_type": "Manufacturing Facility", + "lighting_per_area": 1.24, + "lighting_secondary_space_type": "High bay area (25 to 50 ft floor-to-ceiling height)", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 117, + "method": "SS", + "lighting_primary_space_type": "Manufacturing Facility", + "lighting_per_area": 0.86, + "lighting_secondary_space_type": "Low bay area (< 25 ft floor-to-ceiling height)", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 118, + "method": "SS", + "lighting_primary_space_type": "Museum", + "lighting_per_area": 0.31, + "lighting_secondary_space_type": "General exhibition area", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 119, + "method": "SS", + "lighting_primary_space_type": "Museum", + "lighting_per_area": 1.1, + "lighting_secondary_space_type": "Restoration room", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 120, + "method": "SS", + "lighting_primary_space_type": "Performing Arts Theater\u2014Dressing Room", + "lighting_per_area": 0.41, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 121, + "method": "SS", + "lighting_primary_space_type": "Post Office\u2014Sorting Area", + "lighting_per_area": 0.76, + "lighting_secondary_space_type": "General", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 122, + "method": "SS", + "lighting_primary_space_type": "Religious Facility", + "lighting_per_area": 0.54, + "lighting_secondary_space_type": "Fellowship hall", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 123, + "method": "SS", + "lighting_primary_space_type": "Religious Facility", + "lighting_per_area": 0.85, + "lighting_secondary_space_type": "Worship/pulpit/choir area", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 124, + "method": "SS", + "lighting_primary_space_type": "Retail Facilities", + "lighting_per_area": 0.51, + "lighting_secondary_space_type": "Dressing/fitting room", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 125, + "method": "SS", + "lighting_primary_space_type": "Retail Facilities", + "lighting_per_area": 0.82, + "lighting_secondary_space_type": "Mall concourse", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 126, + "method": "SS", + "lighting_primary_space_type": "Sports Arena\u2014Playing Area", + "lighting_per_area": 2.94, + "lighting_secondary_space_type": "Class I facility", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 127, + "method": "SS", + "lighting_primary_space_type": "Sports Arena\u2014Playing Area", + "lighting_per_area": 2.01, + "lighting_secondary_space_type": "Class II facility", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 128, + "method": "SS", + "lighting_primary_space_type": "Sports Arena\u2014Playing Area", + "lighting_per_area": 1.3, + "lighting_secondary_space_type": "Class III facility", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 129, + "method": "SS", + "lighting_primary_space_type": "Sports Arena\u2014Playing Area", + "lighting_per_area": 0.86, + "lighting_secondary_space_type": "Class IV facility", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 130, + "method": "SS", + "lighting_primary_space_type": "Transportation Facility", + "lighting_per_area": 0.39, + "lighting_secondary_space_type": "Baggage/carousel area", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 131, + "method": "SS", + "lighting_primary_space_type": "Transportation Facility", + "lighting_per_area": 0.25, + "lighting_secondary_space_type": "Airport concourse", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 132, + "method": "SS", + "lighting_primary_space_type": "Transportation Facility", + "lighting_per_area": 0.51, + "lighting_secondary_space_type": "Ticket counter", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 133, + "method": "SS", + "lighting_primary_space_type": "Warehouse\u2014Storage Area", + "lighting_per_area": 0.33, + "lighting_secondary_space_type": "Medium to bulky, palletized items", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 134, + "method": "SS", + "lighting_primary_space_type": "Warehouse\u2014Storage Area", + "lighting_per_area": 0.69, + "lighting_secondary_space_type": "Smaller, hand-carried items", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 135, + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_per_area": 0.45, + "lighting_secondary_space_type": "Sales Additional (Retail Area 1)", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 136, + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_per_area": 0.45, + "lighting_secondary_space_type": "Sales Additional (Retail Area 2)", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 137, + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_per_area": 1.05, + "lighting_secondary_space_type": "Sales Additional (Retail Area 3)", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + }, + { + "id": 138, + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_per_area": 1.88, + "lighting_secondary_space_type": "Sales Additional (Retail Area 4)", + "lighting_per_area_unit": "W/ft2", + "annotation": "" + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/initial_data/light_subspaces.json b/data/openstudio_standards_data/initial_data/light_subspaces.json new file mode 100644 index 0000000000..5532c03ca0 --- /dev/null +++ b/data/openstudio_standards_data/initial_data/light_subspaces.json @@ -0,0 +1,1718 @@ +[ + { + "id": 1, + "lighting_type_name": "bam_automotive_facility", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 1 + }, + { + "id": 2, + "lighting_type_name": "bam_convention_center", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 2 + }, + { + "id": 3, + "lighting_type_name": "bam_courthouse", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 3 + }, + { + "id": 4, + "lighting_type_name": "bam_dinin_bar_lounge_leisure", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 4 + }, + { + "id": 5, + "lighting_type_name": "bam_dining_cafeteria_fast_food", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 5 + }, + { + "id": 6, + "lighting_type_name": "bam_dining_family", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 6 + }, + { + "id": 7, + "lighting_type_name": "bam_dormitory", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 7 + }, + { + "id": 8, + "lighting_type_name": "bam_exercise_center", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 8 + }, + { + "id": 9, + "lighting_type_name": "bam_fire_station", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 23 + }, + { + "id": 10, + "lighting_type_name": "bam_gymnasium", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 9 + }, + { + "id": 11, + "lighting_type_name": "bam_healthcare_clinic", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 10 + }, + { + "id": 12, + "lighting_type_name": "bam_hospital", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 11 + }, + { + "id": 13, + "lighting_type_name": "bam_hotel", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 12 + }, + { + "id": 14, + "lighting_type_name": "bam_library", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 13 + }, + { + "id": 15, + "lighting_type_name": "bam_manufacturing_facility", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 14 + }, + { + "id": 16, + "lighting_type_name": "bam_motel", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 15 + }, + { + "id": 17, + "lighting_type_name": "bam_motion_picture_theater", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 16 + }, + { + "id": 18, + "lighting_type_name": "bam_multifamily", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 17 + }, + { + "id": 19, + "lighting_type_name": "bam_museum", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 18 + }, + { + "id": 20, + "lighting_type_name": "bam_office", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 19 + }, + { + "id": 21, + "lighting_type_name": "bam_parking_garage", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 20 + }, + { + "id": 22, + "lighting_type_name": "bam_penitentiary", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 21 + }, + { + "id": 23, + "lighting_type_name": "bam_performing_arts_theater", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 22 + }, + { + "id": 24, + "lighting_type_name": "bam_police_station", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 23 + }, + { + "id": 25, + "lighting_type_name": "bam_post_office", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 24 + }, + { + "id": 26, + "lighting_type_name": "bam_religious_facility", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 25 + }, + { + "id": 27, + "lighting_type_name": "bam_retail", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 26 + }, + { + "id": 28, + "lighting_type_name": "bam_school_university", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 27 + }, + { + "id": 29, + "lighting_type_name": "bam_sports_arena", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 28 + }, + { + "id": 30, + "lighting_type_name": "bam_town_hall", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 29 + }, + { + "id": 31, + "lighting_type_name": "bam_transportation", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 30 + }, + { + "id": 32, + "lighting_type_name": "bam_warehouse", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 31 + }, + { + "id": 33, + "lighting_type_name": "bam_workshop", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 32 + }, + { + "id": 34, + "lighting_type_name": "office_enclosed_small", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 33 + }, + { + "id": 35, + "lighting_type_name": "office_enclosed_large", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 33 + }, + { + "id": 36, + "lighting_type_name": "office_open", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 34 + }, + { + "id": 37, + "lighting_type_name": "conference_meeting_multipurpose", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 35 + }, + { + "id": 38, + "lighting_type_name": "classroom_lecture_training_general", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 36 + }, + { + "id": 39, + "lighting_type_name": "classroom_lecture_training_penitentiary", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 37 + }, + { + "id": 40, + "lighting_type_name": "lobby_general", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 38 + }, + { + "id": 41, + "lighting_type_name": "lobby_hotel", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 39 + }, + { + "id": 42, + "lighting_type_name": "lobby_performing_arts_theater", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 40 + }, + { + "id": 43, + "lighting_type_name": "lobby_motion_picture_theater", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 41 + }, + { + "id": 44, + "lighting_type_name": "lobby_visually_impaired", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 38 + }, + { + "id": 45, + "lighting_type_name": "lobby_elevator", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 38 + }, + { + "id": 46, + "lighting_type_name": "audience_seating_general", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 42 + }, + { + "id": 47, + "lighting_type_name": "audience_seating_gymnasium", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 43 + }, + { + "id": 48, + "lighting_type_name": "audience_seating_exercise_center", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 44 + }, + { + "id": 49, + "lighting_type_name": "audience_seating_convention_center", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 45 + }, + { + "id": 50, + "lighting_type_name": "audience_seating_penitentiary", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 46 + }, + { + "id": 51, + "lighting_type_name": "audience_seating_religious_facility", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 47 + }, + { + "id": 52, + "lighting_type_name": "audience_seating_sports_arena", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 48 + }, + { + "id": 53, + "lighting_type_name": "audience_seating_performing_arts_theater", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 49 + }, + { + "id": 54, + "lighting_type_name": "audience_seating_motion_picture_theater", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 50 + }, + { + "id": 55, + "lighting_type_name": "audience_seating_transportation", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 51 + }, + { + "id": 56, + "lighting_type_name": "audience_seating_auditorium", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 42 + }, + { + "id": 57, + "lighting_type_name": "atrium_first_three_floor", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 52 + }, + { + "id": 58, + "lighting_type_name": "atrium_each_additional_floor", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 53 + }, + { + "id": 59, + "lighting_type_name": "lounge_breakroom_general", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 54 + }, + { + "id": 60, + "lighting_type_name": "lounge_breakroom_healthcare_facility", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 55 + }, + { + "id": 61, + "lighting_type_name": "dining_general", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 56 + }, + { + "id": 62, + "lighting_type_name": "dining_penitentiary", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 57 + }, + { + "id": 63, + "lighting_type_name": "dining_hotel", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 58 + }, + { + "id": 64, + "lighting_type_name": "dining_motel", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 59 + }, + { + "id": 65, + "lighting_type_name": "dining_bar_lounge_leisure", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 60 + }, + { + "id": 66, + "lighting_type_name": "dining_family", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 61 + }, + { + "id": 67, + "lighting_type_name": "dining_cafeteria_fast_food", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 56 + }, + { + "id": 68, + "lighting_type_name": "dining_visually_impaired", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 56 + }, + { + "id": 69, + "lighting_type_name": "kitchen", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 62 + }, + { + "id": 70, + "lighting_type_name": "laboratory_classroom", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 63 + }, + { + "id": 71, + "lighting_type_name": "laboratory_all_other", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 63 + }, + { + "id": 72, + "lighting_type_name": "restroom_visually_impaired", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 64 + }, + { + "id": 73, + "lighting_type_name": "restroom_all_other", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 64 + }, + { + "id": 74, + "lighting_type_name": "performing_arts_dressing_room", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 65 + }, + { + "id": 75, + "lighting_type_name": "corridor_general", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 66 + }, + { + "id": 76, + "lighting_type_name": "corridor_hospital", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 67 + }, + { + "id": 77, + "lighting_type_name": "corridor_manufacturing_facility", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 68 + }, + { + "id": 78, + "lighting_type_name": "corridor_visually_impaired", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 66 + }, + { + "id": 79, + "lighting_type_name": "stairway", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 69 + }, + { + "id": 80, + "lighting_type_name": "stairwell", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 69 + }, + { + "id": 81, + "lighting_type_name": "storage_ all_other_small", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 70 + }, + { + "id": 82, + "lighting_type_name": "storage_ all_other_large", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 70 + }, + { + "id": 83, + "lighting_type_name": "storage_hospital_small", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 71 + }, + { + "id": 84, + "lighting_type_name": "storage_hospital_large", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 71 + }, + { + "id": 85, + "lighting_type_name": "storage_inactive", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 72 + }, + { + "id": 86, + "lighting_type_name": "storage_inactive_museum", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 73 + }, + { + "id": 87, + "lighting_type_name": "electrical_mechanical", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 74 + }, + { + "id": 88, + "lighting_type_name": "workshop", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 75 + }, + { + "id": 89, + "lighting_type_name": "gymnasium_playing_area", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 76 + }, + { + "id": 90, + "lighting_type_name": "gymnasium_exercise_area", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 77 + }, + { + "id": 91, + "lighting_type_name": "courtroom", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 78 + }, + { + "id": 92, + "lighting_type_name": "confinement_cells", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 79 + }, + { + "id": 93, + "lighting_type_name": "judges_chambers", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 80 + }, + { + "id": 94, + "lighting_type_name": "emergency_vehicle_garage", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 81 + }, + { + "id": 95, + "lighting_type_name": "firestation_sleeping_quarters", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 82 + }, + { + "id": 96, + "lighting_type_name": "post_office_sorting_area", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 83 + }, + { + "id": 97, + "lighting_type_name": "exhibit_convention_center", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 84 + }, + { + "id": 98, + "lighting_type_name": "library_cataloging", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 85 + }, + { + "id": 99, + "lighting_type_name": "library_stacks", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 86 + }, + { + "id": 100, + "lighting_type_name": "library_reading", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 87 + }, + { + "id": 101, + "lighting_type_name": "emergency_room", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 88 + }, + { + "id": 102, + "lighting_type_name": "recovery", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 89 + }, + { + "id": 103, + "lighting_type_name": "nurses_station", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 90 + }, + { + "id": 104, + "lighting_type_name": "exam_treatment", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 91 + }, + { + "id": 105, + "lighting_type_name": "pharmacy", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 92 + }, + { + "id": 106, + "lighting_type_name": "patient_room", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 93 + }, + { + "id": 107, + "lighting_type_name": "operating_room", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 94 + }, + { + "id": 108, + "lighting_type_name": "nursery", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 95 + }, + { + "id": 109, + "lighting_type_name": "medical_supply", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 96 + }, + { + "id": 110, + "lighting_type_name": "physical_therapy", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 97 + }, + { + "id": 111, + "lighting_type_name": "imaging", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 98 + }, + { + "id": 112, + "lighting_type_name": "laundry_washing", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 99 + }, + { + "id": 113, + "lighting_type_name": "automotive", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 100 + }, + { + "id": 114, + "lighting_type_name": "manufacturing_low_bay", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 101 + }, + { + "id": 115, + "lighting_type_name": "manufacturing_high_bay", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 102 + }, + { + "id": 116, + "lighting_type_name": "detailed_manufacuring", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 103 + }, + { + "id": 117, + "lighting_type_name": "manufacturing_equipment_room", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 104 + }, + { + "id": 118, + "lighting_type_name": "manufacturing_control", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 105 + }, + { + "id": 119, + "lighting_type_name": "guest_room", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 106 + }, + { + "id": 120, + "lighting_type_name": "dormitory_living_quarters", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 107 + }, + { + "id": 121, + "lighting_type_name": "museum_exhibit_area", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 108 + }, + { + "id": 122, + "lighting_type_name": "museum_restoration", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 109 + }, + { + "id": 123, + "lighting_type_name": "banking_activity", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 110 + }, + { + "id": 124, + "lighting_type_name": "worship_pulpit_choir_area", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 111 + }, + { + "id": 125, + "lighting_type_name": "fellowship_hall_religious_facility", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 112 + }, + { + "id": 126, + "lighting_type_name": "sales", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 113 + }, + { + "id": 127, + "lighting_type_name": "retail_mall_concourse", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 114 + }, + { + "id": 128, + "lighting_type_name": "sports_arena_ring_sports_area", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 115 + }, + { + "id": 129, + "lighting_type_name": "sports_arena_court_sports_area", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 116 + }, + { + "id": 130, + "lighting_type_name": "sports_arena_indoor_playing_field", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 117 + }, + { + "id": 131, + "lighting_type_name": "warehouse_bulk_storage", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 119 + }, + { + "id": 132, + "lighting_type_name": "parking_area_interior", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 120 + }, + { + "id": 133, + "lighting_type_name": "airport_concourse", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 121 + }, + { + "id": 134, + "lighting_type_name": "baggage_carousel", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 122 + }, + { + "id": 135, + "lighting_type_name": "transportation_ticket_counter", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 123 + }, + { + "id": 136, + "lighting_type_name": "sales_display_type_1", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 124 + }, + { + "id": 137, + "lighting_type_name": "sales_display_type_2", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 124 + }, + { + "id": 138, + "lighting_type_name": "sales_display_type_3", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 125 + }, + { + "id": 139, + "lighting_type_name": "sales_display_type_4", + "lighting_table": "light_def_90_1_2004", + "lpd_901_id": 125 + }, + { + "id": 140, + "lighting_type_name": "bam_automotive_facility", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 1 + }, + { + "id": 141, + "lighting_type_name": "bam_convention_center", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 2 + }, + { + "id": 142, + "lighting_type_name": "bam_courthouse", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 3 + }, + { + "id": 143, + "lighting_type_name": "bam_dinin_bar_lounge_leisure", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 4 + }, + { + "id": 144, + "lighting_type_name": "bam_dining_cafeteria_fast_food", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 5 + }, + { + "id": 145, + "lighting_type_name": "bam_dining_family", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 6 + }, + { + "id": 146, + "lighting_type_name": "bam_dormitory", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 7 + }, + { + "id": 147, + "lighting_type_name": "bam_exercise_center", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 8 + }, + { + "id": 148, + "lighting_type_name": "bam_fire_station", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 9 + }, + { + "id": 149, + "lighting_type_name": "bam_gymnasium", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 10 + }, + { + "id": 150, + "lighting_type_name": "bam_healthcare_clinic", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 11 + }, + { + "id": 151, + "lighting_type_name": "bam_hospital", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 12 + }, + { + "id": 152, + "lighting_type_name": "bam_hotel", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 13 + }, + { + "id": 153, + "lighting_type_name": "bam_library", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 14 + }, + { + "id": 154, + "lighting_type_name": "bam_manufacturing_facility", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 15 + }, + { + "id": 155, + "lighting_type_name": "bam_motel", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 13 + }, + { + "id": 156, + "lighting_type_name": "bam_motion_picture_theater", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 16 + }, + { + "id": 157, + "lighting_type_name": "bam_multifamily", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 17 + }, + { + "id": 158, + "lighting_type_name": "bam_museum", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 18 + }, + { + "id": 159, + "lighting_type_name": "bam_office", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 19 + }, + { + "id": 160, + "lighting_type_name": "bam_parking_garage", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 20 + }, + { + "id": 161, + "lighting_type_name": "bam_penitentiary", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 21 + }, + { + "id": 162, + "lighting_type_name": "bam_performing_arts_theater", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 22 + }, + { + "id": 163, + "lighting_type_name": "bam_police_station", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 23 + }, + { + "id": 164, + "lighting_type_name": "bam_post_office", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 24 + }, + { + "id": 165, + "lighting_type_name": "bam_religious_facility", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 25 + }, + { + "id": 166, + "lighting_type_name": "bam_retail", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 26 + }, + { + "id": 167, + "lighting_type_name": "bam_school_university", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 27 + }, + { + "id": 168, + "lighting_type_name": "bam_sports_arena", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 28 + }, + { + "id": 169, + "lighting_type_name": "bam_town_hall", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 29 + }, + { + "id": 170, + "lighting_type_name": "bam_transportation", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 30 + }, + { + "id": 171, + "lighting_type_name": "bam_warehouse", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 31 + }, + { + "id": 172, + "lighting_type_name": "bam_workshop", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 32 + }, + { + "id": 173, + "lighting_type_name": "office_enclosed_small", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 79 + }, + { + "id": 174, + "lighting_type_name": "office_enclosed_large", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 80 + }, + { + "id": 175, + "lighting_type_name": "office_open", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 81 + }, + { + "id": 176, + "lighting_type_name": "conference_meeting_multipurpose", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 48 + }, + { + "id": 177, + "lighting_type_name": "classroom_lecture_training_general", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 47 + }, + { + "id": 178, + "lighting_type_name": "classroom_lecture_training_penitentiary", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 46 + }, + { + "id": 179, + "lighting_type_name": "lobby_general", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 75 + }, + { + "id": 180, + "lighting_type_name": "lobby_hotel", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 72 + }, + { + "id": 181, + "lighting_type_name": "lobby_performing_arts_theater", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 74 + }, + { + "id": 182, + "lighting_type_name": "lobby_motion_picture_theater", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 73 + }, + { + "id": 183, + "lighting_type_name": "lobby_visually_impaired", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 70 + }, + { + "id": 184, + "lighting_type_name": "lobby_elevator", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 71 + }, + { + "id": 185, + "lighting_type_name": "audience_seating_general", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 43 + }, + { + "id": 186, + "lighting_type_name": "audience_seating_gymnasium", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 37 + }, + { + "id": 187, + "lighting_type_name": "audience_seating_exercise_center", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 43 + }, + { + "id": 188, + "lighting_type_name": "audience_seating_convention_center", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 43 + }, + { + "id": 189, + "lighting_type_name": "audience_seating_penitentiary", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 39 + }, + { + "id": 190, + "lighting_type_name": "audience_seating_religious_facility", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 41 + }, + { + "id": 191, + "lighting_type_name": "audience_seating_sports_arena", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 42 + }, + { + "id": 192, + "lighting_type_name": "audience_seating_performing_arts_theater", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 40 + }, + { + "id": 193, + "lighting_type_name": "audience_seating_motion_picture_theater", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 38 + }, + { + "id": 194, + "lighting_type_name": "audience_seating_transportation", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 43 + }, + { + "id": 195, + "lighting_type_name": "audience_seating_auditorium", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 36 + }, + { + "id": 196, + "lighting_type_name": "atrium_low", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 33 + }, + { + "id": 197, + "lighting_type_name": "atrium_medium", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 34 + }, + { + "id": 198, + "lighting_type_name": "atrium_high", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 35 + }, + { + "id": 199, + "lighting_type_name": "lounge_breakroom_general", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 78 + }, + { + "id": 200, + "lighting_type_name": "lounge_breakroom_healthcare_facility", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 77 + }, + { + "id": 201, + "lighting_type_name": "dining_general", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 61 + }, + { + "id": 202, + "lighting_type_name": "dining_penitentiary", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 56 + }, + { + "id": 203, + "lighting_type_name": "dining_hotel", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 61 + }, + { + "id": 204, + "lighting_type_name": "dining_motel", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 61 + }, + { + "id": 205, + "lighting_type_name": "dining_bar_lounge_leisure", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 58 + }, + { + "id": 206, + "lighting_type_name": "dining_family", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 60 + }, + { + "id": 207, + "lighting_type_name": "dining_cafeteria_fast_food", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 59 + }, + { + "id": 208, + "lighting_type_name": "dining_visually_impaired", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 57 + }, + { + "id": 209, + "lighting_type_name": "kitchen", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 64 + }, + { + "id": 210, + "lighting_type_name": "laboratory_classroom", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 66 + }, + { + "id": 211, + "lighting_type_name": "laboratory_all_other", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 67 + }, + { + "id": 212, + "lighting_type_name": "restroom_visually_impaired", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 84 + }, + { + "id": 213, + "lighting_type_name": "restroom_all_other", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 85 + }, + { + "id": 214, + "lighting_type_name": "performing_arts_dressing_room", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 120 + }, + { + "id": 215, + "lighting_type_name": "corridor_general", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 53 + }, + { + "id": 216, + "lighting_type_name": "corridor_hospital", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 52 + }, + { + "id": 217, + "lighting_type_name": "corridor_manufacturing_facility", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 53 + }, + { + "id": 218, + "lighting_type_name": "corridor_visually_impaired", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 51 + }, + { + "id": 219, + "lighting_type_name": "stairway", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 88 + }, + { + "id": 220, + "lighting_type_name": "stairwell", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 89 + }, + { + "id": 221, + "lighting_type_name": "storage_ all_other_small", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 90 + }, + { + "id": 222, + "lighting_type_name": "storage_ all_other_large", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 91 + }, + { + "id": 223, + "lighting_type_name": "storage_hospital_small", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 90 + }, + { + "id": 224, + "lighting_type_name": "storage_hospital_large", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 91 + }, + { + "id": 225, + "lighting_type_name": "electrical_mechanical", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 62 + }, + { + "id": 226, + "lighting_type_name": "workshop", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 93 + }, + { + "id": 227, + "lighting_type_name": "gymnasium_playing_area", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 101 + }, + { + "id": 228, + "lighting_type_name": "gymnasium_exercise_area", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 100 + }, + { + "id": 229, + "lighting_type_name": "courtroom", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 54 + }, + { + "id": 230, + "lighting_type_name": "confinement_cells", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 49 + }, + { + "id": 231, + "lighting_type_name": "emergency_vehicle_garage", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 63 + }, + { + "id": 232, + "lighting_type_name": "firestation_sleeping_quarters", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 99 + }, + { + "id": 233, + "lighting_type_name": "post_office_sorting_area", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 121 + }, + { + "id": 234, + "lighting_type_name": "exhibit_convention_center", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 97 + }, + { + "id": 235, + "lighting_type_name": "library_stacks", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 112 + }, + { + "id": 236, + "lighting_type_name": "library_reading", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 111 + }, + { + "id": 237, + "lighting_type_name": "recovery", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 110 + }, + { + "id": 238, + "lighting_type_name": "nurses_station", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 106 + }, + { + "id": 239, + "lighting_type_name": "exam_treatment", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 102 + }, + { + "id": 240, + "lighting_type_name": "pharmacy", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 83 + }, + { + "id": 241, + "lighting_type_name": "patient_room", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 108 + }, + { + "id": 242, + "lighting_type_name": "operating_room", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 107 + }, + { + "id": 243, + "lighting_type_name": "nursery", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 105 + }, + { + "id": 244, + "lighting_type_name": "medical_supply", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 104 + }, + { + "id": 245, + "lighting_type_name": "physical_therapy", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 109 + }, + { + "id": 246, + "lighting_type_name": "imaging", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 103 + }, + { + "id": 247, + "lighting_type_name": "laundry_washing", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 68 + }, + { + "id": 248, + "lighting_type_name": "automotive", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 96 + }, + { + "id": 249, + "lighting_type_name": "manufacturing_low_bay", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 117 + }, + { + "id": 250, + "lighting_type_name": "manufacturing_high_bay", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 116 + }, + { + "id": 251, + "lighting_type_name": "detailed_manufacuring", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 113 + }, + { + "id": 252, + "lighting_type_name": "manufacturing_equipment_room", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 114 + }, + { + "id": 253, + "lighting_type_name": "manufacturing_extra_high_bay", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 115 + }, + { + "id": 254, + "lighting_type_name": "guest_room", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 65 + }, + { + "id": 255, + "lighting_type_name": "dormitory_living_quarters", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 98 + }, + { + "id": 256, + "lighting_type_name": "museum_exhibit_area", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 118 + }, + { + "id": 257, + "lighting_type_name": "museum_restoration", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 119 + }, + { + "id": 258, + "lighting_type_name": "banking_activity", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 44 + }, + { + "id": 259, + "lighting_type_name": "worship_pulpit_choir_area", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 123 + }, + { + "id": 260, + "lighting_type_name": "fellowship_hall_religious_facility", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 122 + }, + { + "id": 261, + "lighting_type_name": "sales", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 86 + }, + { + "id": 262, + "lighting_type_name": "retail_mall_concourse", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 125 + }, + { + "id": 263, + "lighting_type_name": "retail_dressing_room", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 124 + }, + { + "id": 264, + "lighting_type_name": "sports_arena_playing_area_class_I", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 126 + }, + { + "id": 265, + "lighting_type_name": "sports_arena_playing_area_class_II", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 127 + }, + { + "id": 266, + "lighting_type_name": "sports_arena_playing_area_class_III", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 128 + }, + { + "id": 267, + "lighting_type_name": "sports_arena_playing_area_class_IV", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 129 + }, + { + "id": 268, + "lighting_type_name": "warehouse_fine_storage", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 134 + }, + { + "id": 269, + "lighting_type_name": "warehouse_bulk_storage", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 133 + }, + { + "id": 270, + "lighting_type_name": "parking_area_interior", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 82 + }, + { + "id": 271, + "lighting_type_name": "airport_concourse", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 131 + }, + { + "id": 272, + "lighting_type_name": "baggage_carousel", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 130 + }, + { + "id": 273, + "lighting_type_name": "transportation_ticket_counter", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 132 + }, + { + "id": 274, + "lighting_type_name": "sales_display_type_1", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 135 + }, + { + "id": 275, + "lighting_type_name": "sales_display_type_2", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 136 + }, + { + "id": 276, + "lighting_type_name": "sales_display_type_3", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 137 + }, + { + "id": 277, + "lighting_type_name": "sales_display_type_4", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 138 + }, + { + "id": 278, + "lighting_type_name": "breakroom", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 45 + }, + { + "id": 279, + "lighting_type_name": "copy_print", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 50 + }, + { + "id": 280, + "lighting_type_name": "computer_room", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 55 + }, + { + "id": 281, + "lighting_type_name": "loading_dock", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 69 + }, + { + "id": 282, + "lighting_type_name": "locker_room", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 76 + }, + { + "id": 283, + "lighting_type_name": "seating_area_general", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 87 + }, + { + "id": 284, + "lighting_type_name": "vehicular_maintenance", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 92 + }, + { + "id": 285, + "lighting_type_name": "chapel_visually_impaired", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 94 + }, + { + "id": 286, + "lighting_type_name": "recreation_common_living_visually_impaired", + "lighting_table": "light_def_90_1_2019", + "lpd_901_id": 95 + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/initial_data/lighting_space_tag.json b/data/openstudio_standards_data/initial_data/lighting_space_tag.json new file mode 100644 index 0000000000..44a2358648 --- /dev/null +++ b/data/openstudio_standards_data/initial_data/lighting_space_tag.json @@ -0,0 +1,476 @@ +[ + { + "lighting_space_tag": "bam_automotive_facility" + }, + { + "lighting_space_tag": "bam_convention_center" + }, + { + "lighting_space_tag": "bam_courthouse" + }, + { + "lighting_space_tag": "bam_dinin_bar_lounge_leisure" + }, + { + "lighting_space_tag": "bam_dining_cafeteria_fast_food" + }, + { + "lighting_space_tag": "bam_dining_family" + }, + { + "lighting_space_tag": "bam_dormitory" + }, + { + "lighting_space_tag": "bam_exercise_center" + }, + { + "lighting_space_tag": "bam_fire_station" + }, + { + "lighting_space_tag": "bam_gymnasium" + }, + { + "lighting_space_tag": "bam_healthcare_clinic" + }, + { + "lighting_space_tag": "bam_hospital" + }, + { + "lighting_space_tag": "bam_hotel" + }, + { + "lighting_space_tag": "bam_library" + }, + { + "lighting_space_tag": "bam_manufacturing_facility" + }, + { + "lighting_space_tag": "bam_motel" + }, + { + "lighting_space_tag": "bam_motion_picture_theater" + }, + { + "lighting_space_tag": "bam_multifamily" + }, + { + "lighting_space_tag": "bam_museum" + }, + { + "lighting_space_tag": "bam_office" + }, + { + "lighting_space_tag": "bam_parking_garage" + }, + { + "lighting_space_tag": "bam_penitentiary" + }, + { + "lighting_space_tag": "bam_performing_arts_theater" + }, + { + "lighting_space_tag": "bam_police_station" + }, + { + "lighting_space_tag": "bam_post_office" + }, + { + "lighting_space_tag": "bam_religious_facility" + }, + { + "lighting_space_tag": "bam_retail" + }, + { + "lighting_space_tag": "bam_school_university" + }, + { + "lighting_space_tag": "bam_sports_arena" + }, + { + "lighting_space_tag": "bam_town_hall" + }, + { + "lighting_space_tag": "bam_transportation" + }, + { + "lighting_space_tag": "bam_warehouse" + }, + { + "lighting_space_tag": "bam_workshop" + }, + { + "lighting_space_tag": "office_enclosed_small" + }, + { + "lighting_space_tag": "office_enclosed_large" + }, + { + "lighting_space_tag": "office_open" + }, + { + "lighting_space_tag": "conference_meeting_multipurpose" + }, + { + "lighting_space_tag": "classroom_lecture_training_general" + }, + { + "lighting_space_tag": "classroom_lecture_training_penitentiary" + }, + { + "lighting_space_tag": "lobby_general" + }, + { + "lighting_space_tag": "lobby_hotel" + }, + { + "lighting_space_tag": "lobby_performing_arts_theater" + }, + { + "lighting_space_tag": "lobby_motion_picture_theater" + }, + { + "lighting_space_tag": "lobby_visually_impaired" + }, + { + "lighting_space_tag": "lobby_elevator" + }, + { + "lighting_space_tag": "audience_seating_general" + }, + { + "lighting_space_tag": "audience_seating_gymnasium" + }, + { + "lighting_space_tag": "audience_seating_exercise_center" + }, + { + "lighting_space_tag": "audience_seating_convention_center" + }, + { + "lighting_space_tag": "audience_seating_penitentiary" + }, + { + "lighting_space_tag": "audience_seating_religious_facility" + }, + { + "lighting_space_tag": "audience_seating_sports_arena" + }, + { + "lighting_space_tag": "audience_seating_performing_arts_theater" + }, + { + "lighting_space_tag": "audience_seating_motion_picture_theater" + }, + { + "lighting_space_tag": "audience_seating_transportation" + }, + { + "lighting_space_tag": "audience_seating_auditorium" + }, + { + "lighting_space_tag": "atrium_first_three_floor" + }, + { + "lighting_space_tag": "atrium_each_additional_floor" + }, + { + "lighting_space_tag": "atrium_low" + }, + { + "lighting_space_tag": "atrium_medium" + }, + { + "lighting_space_tag": "atrium_high" + }, + { + "lighting_space_tag": "lounge_breakroom_general" + }, + { + "lighting_space_tag": "lounge_breakroom_healthcare_facility" + }, + { + "lighting_space_tag": "dining_general" + }, + { + "lighting_space_tag": "dining_penitentiary" + }, + { + "lighting_space_tag": "dining_hotel" + }, + { + "lighting_space_tag": "dining_motel" + }, + { + "lighting_space_tag": "dining_bar_lounge_leisure" + }, + { + "lighting_space_tag": "dining_family" + }, + { + "lighting_space_tag": "dining_cafeteria_fast_food" + }, + { + "lighting_space_tag": "dining_visually_impaired" + }, + { + "lighting_space_tag": "kitchen" + }, + { + "lighting_space_tag": "laboratory_classroom" + }, + { + "lighting_space_tag": "laboratory_all_other" + }, + { + "lighting_space_tag": "restroom_visually_impaired" + }, + { + "lighting_space_tag": "restroom_all_other" + }, + { + "lighting_space_tag": "performing_arts_dressing_room" + }, + { + "lighting_space_tag": "corridor_general" + }, + { + "lighting_space_tag": "corridor_hospital" + }, + { + "lighting_space_tag": "corridor_manufacturing_facility" + }, + { + "lighting_space_tag": "corridor_visually_impaired" + }, + { + "lighting_space_tag": "stairway" + }, + { + "lighting_space_tag": "stairwell" + }, + { + "lighting_space_tag": "storage_ all_other_small" + }, + { + "lighting_space_tag": "storage_ all_other_large" + }, + { + "lighting_space_tag": "storage_hospital_small" + }, + { + "lighting_space_tag": "storage_hospital_large" + }, + { + "lighting_space_tag": "storage_inactive" + }, + { + "lighting_space_tag": "storage_inactive_museum" + }, + { + "lighting_space_tag": "electrical_mechanical" + }, + { + "lighting_space_tag": "workshop" + }, + { + "lighting_space_tag": "gymnasium_playing_area" + }, + { + "lighting_space_tag": "gymnasium_exercise_area" + }, + { + "lighting_space_tag": "courtroom" + }, + { + "lighting_space_tag": "confinement_cells" + }, + { + "lighting_space_tag": "judges_chambers" + }, + { + "lighting_space_tag": "emergency_vehicle_garage" + }, + { + "lighting_space_tag": "firestation_sleeping_quarters" + }, + { + "lighting_space_tag": "post_office_sorting_area" + }, + { + "lighting_space_tag": "exhibit_convention_center" + }, + { + "lighting_space_tag": "library_cataloging" + }, + { + "lighting_space_tag": "library_stacks" + }, + { + "lighting_space_tag": "library_reading" + }, + { + "lighting_space_tag": "emergency_room" + }, + { + "lighting_space_tag": "recovery" + }, + { + "lighting_space_tag": "nurses_station" + }, + { + "lighting_space_tag": "exam_treatment" + }, + { + "lighting_space_tag": "pharmacy" + }, + { + "lighting_space_tag": "patient_room" + }, + { + "lighting_space_tag": "operating_room" + }, + { + "lighting_space_tag": "nursery" + }, + { + "lighting_space_tag": "medical_supply" + }, + { + "lighting_space_tag": "physical_therapy" + }, + { + "lighting_space_tag": "imaging" + }, + { + "lighting_space_tag": "laundry_washing" + }, + { + "lighting_space_tag": "automotive" + }, + { + "lighting_space_tag": "manufacturing_low_bay" + }, + { + "lighting_space_tag": "manufacturing_high_bay" + }, + { + "lighting_space_tag": "detailed_manufacuring" + }, + { + "lighting_space_tag": "manufacturing_equipment_room" + }, + { + "lighting_space_tag": "manufacturing_control" + }, + { + "lighting_space_tag": "manufacturing_extra_high_bay" + }, + { + "lighting_space_tag": "guest_room" + }, + { + "lighting_space_tag": "dormitory_living_quarters" + }, + { + "lighting_space_tag": "museum_exhibit_area" + }, + { + "lighting_space_tag": "museum_restoration" + }, + { + "lighting_space_tag": "banking_activity" + }, + { + "lighting_space_tag": "worship_pulpit_choir_area" + }, + { + "lighting_space_tag": "fellowship_hall_religious_facility" + }, + { + "lighting_space_tag": "sales" + }, + { + "lighting_space_tag": "retail_mall_concourse" + }, + { + "lighting_space_tag": "retail_dressing_room" + }, + { + "lighting_space_tag": "sports_arena_ring_sports_area" + }, + { + "lighting_space_tag": "sports_arena_court_sports_area" + }, + { + "lighting_space_tag": "sports_arena_indoor_playing_field" + }, + { + "lighting_space_tag": "sports_arena_playing_area_class_I" + }, + { + "lighting_space_tag": "sports_arena_playing_area_class_II" + }, + { + "lighting_space_tag": "sports_arena_playing_area_class_III" + }, + { + "lighting_space_tag": "sports_arena_playing_area_class_IV" + }, + { + "lighting_space_tag": "warehouse_fine_storage" + }, + { + "lighting_space_tag": "warehouse_bulk_storage" + }, + { + "lighting_space_tag": "parking_area_interior" + }, + { + "lighting_space_tag": "airport_concourse" + }, + { + "lighting_space_tag": "baggage_carousel" + }, + { + "lighting_space_tag": "transportation_ticket_counter" + }, + { + "lighting_space_tag": "sales_display_type_1" + }, + { + "lighting_space_tag": "sales_display_type_2" + }, + { + "lighting_space_tag": "sales_display_type_3" + }, + { + "lighting_space_tag": "sales_display_type_4" + }, + { + "lighting_space_tag": "breakroom" + }, + { + "lighting_space_tag": "copy_print" + }, + { + "lighting_space_tag": "computer_room" + }, + { + "lighting_space_tag": "loading_dock" + }, + { + "lighting_space_tag": "locker_room" + }, + { + "lighting_space_tag": "seating_area_general" + }, + { + "lighting_space_tag": "vehicular_maintenance" + }, + { + "lighting_space_tag": "chapel_visually_impaired" + }, + { + "lighting_space_tag": "recreation_common_living_visually_impaired" + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/initial_data/plug_load_space_tag.json b/data/openstudio_standards_data/initial_data/plug_load_space_tag.json new file mode 100644 index 0000000000..e67cf6acce --- /dev/null +++ b/data/openstudio_standards_data/initial_data/plug_load_space_tag.json @@ -0,0 +1,464 @@ +[ + { + "plug_load_space_tag": "corridor - all other" + }, + { + "plug_load_space_tag": "dining - all other" + }, + { + "plug_load_space_tag": "electrical/mechanical" + }, + { + "plug_load_space_tag": "kitchen" + }, + { + "plug_load_space_tag": "laboratory" + }, + { + "plug_load_space_tag": "lobby - all other" + }, + { + "plug_load_space_tag": "locker room" + }, + { + "plug_load_space_tag": "lounge/breakroom - all other" + }, + { + "plug_load_space_tag": "office - enclosed <= 250 sf" + }, + { + "plug_load_space_tag": "office - enclosed > 250 sf" + }, + { + "plug_load_space_tag": "office - open" + }, + { + "plug_load_space_tag": "restroom - all other" + }, + { + "plug_load_space_tag": "stairwell" + }, + { + "plug_load_space_tag": "storage < 50 sf - all other" + }, + { + "plug_load_space_tag": "storage 50 to 1000 sf - all other" + }, + { + "plug_load_space_tag": "vehicular maintenance" + }, + { + "plug_load_space_tag": "atrium - first three floors" + }, + { + "plug_load_space_tag": "audience seating - convention center" + }, + { + "plug_load_space_tag": "classroom/lecture/training - all other" + }, + { + "plug_load_space_tag": "conference/meeting/multipurpose" + }, + { + "plug_load_space_tag": "exhibit - convention center" + }, + { + "plug_load_space_tag": "gymnasium exercise area" + }, + { + "plug_load_space_tag": "gymnasium playing area" + }, + { + "plug_load_space_tag": "laundry/washing" + }, + { + "plug_load_space_tag": "lobby - elevator" + }, + { + "plug_load_space_tag": "nurses station" + }, + { + "plug_load_space_tag": "post office - sorting area" + }, + { + "plug_load_space_tag": "sports arena playing area, class IV" + }, + { + "plug_load_space_tag": "audience seating - all other" + }, + { + "plug_load_space_tag": "confinement cells" + }, + { + "plug_load_space_tag": "judges chambers" + }, + { + "plug_load_space_tag": "library - stacks" + }, + { + "plug_load_space_tag": "storage - inactive" + }, + { + "plug_load_space_tag": "dining - bar/lounge/leisure" + }, + { + "plug_load_space_tag": "dining - cafeteria/fast food" + }, + { + "plug_load_space_tag": "dining - family" + }, + { + "plug_load_space_tag": "computer room" + }, + { + "plug_load_space_tag": "dormitory - living quarters" + }, + { + "plug_load_space_tag": "audience seating - exercise center" + }, + { + "plug_load_space_tag": "exam/treatment" + }, + { + "plug_load_space_tag": "library - reading" + }, + { + "plug_load_space_tag": "emergency vehicle garage" + }, + { + "plug_load_space_tag": "firestation - sleeping quarters" + }, + { + "plug_load_space_tag": "parking area, interior" + }, + { + "plug_load_space_tag": "audience seating - gymnasium" + }, + { + "plug_load_space_tag": "emergency room" + }, + { + "plug_load_space_tag": "patient room" + }, + { + "plug_load_space_tag": "corridor - hospital" + }, + { + "plug_load_space_tag": "fellowship hall - religious facility" + }, + { + "plug_load_space_tag": "lounge/breakroom - healthcare facility" + }, + { + "plug_load_space_tag": "operating room" + }, + { + "plug_load_space_tag": "physical therapy" + }, + { + "plug_load_space_tag": "storage < 50 sf - hospital" + }, + { + "plug_load_space_tag": "storage 50 to 1000 sf - hospital" + }, + { + "plug_load_space_tag": "guest room" + }, + { + "plug_load_space_tag": "lobby - hotel" + }, + { + "plug_load_space_tag": "library - cataloging" + }, + { + "plug_load_space_tag": "museum exhibit area" + }, + { + "plug_load_space_tag": "corridor - manufacturing facility" + }, + { + "plug_load_space_tag": "manufacturing equipment room" + }, + { + "plug_load_space_tag": "manufacturing low bay" + }, + { + "plug_load_space_tag": "performing arts dressing room" + }, + { + "plug_load_space_tag": "audience seating - auditorium" + }, + { + "plug_load_space_tag": "audience seating - motion picture theater" + }, + { + "plug_load_space_tag": "lobby - motion picture theater" + }, + { + "plug_load_space_tag": "Dwelling Unit" + }, + { + "plug_load_space_tag": "museum restoration" + }, + { + "plug_load_space_tag": "banking activity" + }, + { + "plug_load_space_tag": "warehouse - fine storage" + }, + { + "plug_load_space_tag": "classroom/lecture/training - penitentiary" + }, + { + "plug_load_space_tag": "dining - penitentiary" + }, + { + "plug_load_space_tag": "audience seating - performing arts theater" + }, + { + "plug_load_space_tag": "lobby - performing arts theater" + }, + { + "plug_load_space_tag": "audience seating - religious facility" + }, + { + "plug_load_space_tag": "worship/pulpit/choir area" + }, + { + "plug_load_space_tag": "classroom/lecture/training - preschool to 12th" + }, + { + "plug_load_space_tag": "sports arena playing area, class II" + }, + { + "plug_load_space_tag": "audience seating - sports arena" + }, + { + "plug_load_space_tag": "airport concourse" + }, + { + "plug_load_space_tag": "atrium < 20 ft height" + }, + { + "plug_load_space_tag": "atrium > 40 ft height" + }, + { + "plug_load_space_tag": "atrium >= 20 ft and <= 40 ft in height" + }, + { + "plug_load_space_tag": "baggage/carousel" + }, + { + "plug_load_space_tag": "seating area, general" + }, + { + "plug_load_space_tag": "transportation ticket counter" + }, + { + "plug_load_space_tag": "warehouse - bulk storage" + }, + { + "plug_load_space_tag": "workshop" + }, + { + "plug_load_space_tag": "gymnasium_playing_area" + }, + { + "plug_load_space_tag": "gymnasium_exercise_area" + }, + { + "plug_load_space_tag": "courtroom" + }, + { + "plug_load_space_tag": "confinement_cells" + }, + { + "plug_load_space_tag": "judges_chambers" + }, + { + "plug_load_space_tag": "emergency_vehicle_garage" + }, + { + "plug_load_space_tag": "firestation_sleeping_quarters" + }, + { + "plug_load_space_tag": "post_office_sorting_area" + }, + { + "plug_load_space_tag": "exhibit_convention_center" + }, + { + "plug_load_space_tag": "library_cataloging" + }, + { + "plug_load_space_tag": "library_stacks" + }, + { + "plug_load_space_tag": "library_reading" + }, + { + "plug_load_space_tag": "emergency_room" + }, + { + "plug_load_space_tag": "recovery" + }, + { + "plug_load_space_tag": "nurses_station" + }, + { + "plug_load_space_tag": "exam_treatment" + }, + { + "plug_load_space_tag": "pharmacy" + }, + { + "plug_load_space_tag": "patient_room" + }, + { + "plug_load_space_tag": "operating_room" + }, + { + "plug_load_space_tag": "nursery" + }, + { + "plug_load_space_tag": "medical_supply" + }, + { + "plug_load_space_tag": "physical_therapy" + }, + { + "plug_load_space_tag": "imaging" + }, + { + "plug_load_space_tag": "laundry_washing" + }, + { + "plug_load_space_tag": "automotive" + }, + { + "plug_load_space_tag": "manufacturing_low_bay" + }, + { + "plug_load_space_tag": "manufacturing_high_bay" + }, + { + "plug_load_space_tag": "detailed_manufacuring" + }, + { + "plug_load_space_tag": "manufacturing_equipment_room" + }, + { + "plug_load_space_tag": "manufacturing_control" + }, + { + "plug_load_space_tag": "manufacturing_extra_high_bay" + }, + { + "plug_load_space_tag": "guest_room" + }, + { + "plug_load_space_tag": "dormitory_living_quarters" + }, + { + "plug_load_space_tag": "museum_exhibit_area" + }, + { + "plug_load_space_tag": "museum_restoration" + }, + { + "plug_load_space_tag": "banking_activity" + }, + { + "plug_load_space_tag": "worship_pulpit_choir_area" + }, + { + "plug_load_space_tag": "fellowship_hall_religious_facility" + }, + { + "plug_load_space_tag": "sales" + }, + { + "plug_load_space_tag": "retail_mall_concourse" + }, + { + "plug_load_space_tag": "retail_dressing_room" + }, + { + "plug_load_space_tag": "sports_arena_ring_sports_area" + }, + { + "plug_load_space_tag": "sports_arena_court_sports_area" + }, + { + "plug_load_space_tag": "sports_arena_indoor_playing_field" + }, + { + "plug_load_space_tag": "sports_arena_playing_area_class_I" + }, + { + "plug_load_space_tag": "sports_arena_playing_area_class_II" + }, + { + "plug_load_space_tag": "sports_arena_playing_area_class_III" + }, + { + "plug_load_space_tag": "sports_arena_playing_area_class_IV" + }, + { + "plug_load_space_tag": "warehouse_fine_storage" + }, + { + "plug_load_space_tag": "warehouse_bulk_storage" + }, + { + "plug_load_space_tag": "parking_area_interior" + }, + { + "plug_load_space_tag": "airport_concourse" + }, + { + "plug_load_space_tag": "baggage_carousel" + }, + { + "plug_load_space_tag": "transportation_ticket_counter" + }, + { + "plug_load_space_tag": "sales_display_type_1" + }, + { + "plug_load_space_tag": "sales_display_type_2" + }, + { + "plug_load_space_tag": "sales_display_type_3" + }, + { + "plug_load_space_tag": "sales_display_type_4" + }, + { + "plug_load_space_tag": "breakroom" + }, + { + "plug_load_space_tag": "copy_print" + }, + { + "plug_load_space_tag": "computer_room" + }, + { + "plug_load_space_tag": "loading_dock" + }, + { + "plug_load_space_tag": "locker_room" + }, + { + "plug_load_space_tag": "seating_area_general" + }, + { + "plug_load_space_tag": "vehicular_maintenance" + }, + { + "plug_load_space_tag": "chapel_visually_impaired" + }, + { + "plug_load_space_tag": "recreation_common_living_visually_impaired" + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/initial_data/standard_template.json b/data/openstudio_standards_data/initial_data/standard_template.json new file mode 100644 index 0000000000..18e6f9b0fc --- /dev/null +++ b/data/openstudio_standards_data/initial_data/standard_template.json @@ -0,0 +1,18 @@ +[ + { + "id": 1, + "template": "2019", + "lighting_standard": "ASHRAE 90.1-2019", + "lighting_standard_table": "light_def_90_1_2019", + "ventilation_standard": "ASHRAE 62.1-2019", + "ventilation_standard_table": "vent_def_62_1_2019" + }, + { + "id": 2, + "template": "2004", + "lighting_standard": "ASHRAE 90.1-2004", + "lighting_standard_table": "light_def_90_1_2004", + "ventilation_standard": "ASHRAE 62.1-2004", + "ventilation_standard_table": "vent_def_62_1_2004" + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/initial_data/support_constructions.csv b/data/openstudio_standards_data/initial_data/support_constructions.csv new file mode 100644 index 0000000000..be2b48475b --- /dev/null +++ b/data/openstudio_standards_data/initial_data/support_constructions.csv @@ -0,0 +1,492 @@ +name,intended_surface_type,standard_construction_type,insulation_layer,skylight_framing,material_1,material_2,material_3,material_4,material_5,material_6 +Typical Attic Floor,AtticFloor,WoodFramed,Typical Insulation,,1/2IN Gypsum,Typical Insulation,1/2IN Gypsum,,, +Typical Wood Joist Attic Floor,AtticFloor,WoodFramed,Typical Insulation,,5/8 in. Gypsum Board,Typical Insulation,,,, +Typical Wood Joist Attic Floor Ceiling,AtticFloor,WoodFramed,,,Typical Insulation,5/8 in. Gypsum Board,,,, +Typical Uninsulated Metal Roof Attic Roof,AtticRoof,WoodFramed,,,Roof Membrane,Metal Decking,,,, +Typical Uninsulated Wood Joist Attic Roof,AtticRoof,WoodFramed,,,Asphalt Shingles,5/8 in. Plywood,,,, +Typical Attic Soffit,AtticWall,,,,5/8 in. Plywood,,,,, +Typical Insulated Metal Door,ExteriorDoor,,Typical Insulation,,F08 Metal surface,Typical Insulation,,,, +Typical Overhead Door,ExteriorDoor,RollUp,Typical Insulation,,Typical Insulation,,,,, +Typical Uninsulated Swinging Door,ExteriorDoor,Swinging,Typical Insulation,,Typical Insulation,,,,, +Adiabatic ExteriorFloor,ExteriorFloor,Mass,,,Adiabatic Material,,,,, +Typical Carpeted 4in Slab Floor,ExteriorFloor,,,,MAT-CC05 4 HW CONCRETE,Typical Carpet Pad,,,, +Typical Insulated Carpeted 4in Slab Floor,ExteriorFloor,,Typical Insulation,,Typical Insulation,MAT-CC05 4 HW CONCRETE,Typical Carpet Pad,,, +Typical Insulated Exterior Mass Floor,ExteriorFloor,Mass,Typical Insulation,,Typical Insulation,4 in. Normalweight Concrete Floor,Typical Carpet Pad,,, +Typical Insulated Exterior Mass Floor Ceiling,ExteriorFloor,Mass,Typical Insulation,,Typical Carpet Pad,4 in. Normalweight Concrete Floor,Typical Insulation,,, +Typical Insulated Steel Framed Exterior Floor,ExteriorFloor,SteelFramed,Typical Insulation,,25mm Stucco,5/8 in. Gypsum Board,Typical Insulation,5/8 in. Gypsum Board,Typical Carpet Pad, +Typical Insulated Wood Framed Exterior Floor,ExteriorFloor,WoodFramed,Typical Insulation,,25mm Stucco,5/8 in. Gypsum Board,Typical Insulation,5/8 in. Gypsum Board,Typical Carpet Pad, +Typical Uncarpeted 4in Slab Floor,ExteriorFloor,,,,MAT-CC05 4 HW CONCRETE,,,,, +Adiabatic Roof,ExteriorRoof,Attic and Other,,,Adiabatic Material,,,,, +Metal roofR_R30,ExteriorRoof,,Typical Insulation,,Metal Standing Seam - 1/16 in. CBES,R_R30,,,, +Metal roofR_R38,ExteriorRoof,,Typical Insulation,,Metal Standing Seam - 1/16 in. CBES,R_R38,,,, +Metal roofR_T24_2013_24.86,ExteriorRoof,,Typical Insulation,,Metal Standing Seam - 1/16 in. CBES,R_T24_2013_24.86,,,, +Metal roofR1_R14.20,ExteriorRoof,,Typical Insulation,,Metal Standing Seam - 1/16 in. CBES,R1_R14.20,,,, +Metal roofR2_R12.90,ExteriorRoof,,Typical Insulation,,Metal Standing Seam - 1/16 in. CBES,R2_R12.90,,,, +Metal roofR3_R17.74,ExteriorRoof,,Typical Insulation,,Metal Standing Seam - 1/16 in. CBES,R3_R17.74,,,, +Metal roofR4_R20.28,ExteriorRoof,,Typical Insulation,,Metal Standing Seam - 1/16 in. CBES,R4_R20.28,,,, +Typical Built Up Roof,ExteriorRoof,IEAD,Typical Insulation,,Built-up Roofing,Typical Insulation,Metal Surface,,, +Typical Built Up Roof - Highly Reflective,ExteriorRoof,IEAD,Typical Insulation,,Built-up Roofing - Highly Reflective,Typical Insulation,Metal Surface,,, +Typical IEAD Roof,ExteriorRoof,IEAD,Typical Insulation,,Roof Membrane,Typical Insulation,Metal Roof Surface,,, +Typical IEAD Roof - Highly Reflective,ExteriorRoof,IEAD,Typical Insulation,,Roof Membrane - Highly Reflective,Typical Insulation,Metal Roof Surface,,, +Typical Insulated Metal Building Roof,ExteriorRoof,Metal Building,Typical Insulation,,Metal Roof Surface,Typical Insulation,,,, +Typical Insulated Metal Building Roof - Highly Reflective,ExteriorRoof,Metal Building,Typical Insulation,,Metal Roof Surface - Highly Reflective,Typical Insulation,,,, +Typical Uninsulated Metal Building Roof,ExteriorRoof,Metal Building,,,Metal Roofing,,,,, +Typical Uninsulated Metal Building Roof - Highly Reflective,ExteriorRoof,Metal Building,,,Metal Roofing - Highly Reflective,,,,, +Adiabatic Wall,ExteriorWall,Mass,,,Adiabatic Material,,,,, +Metal framed wallsW_m1_R15,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W_m1_R15,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, +Metal framed wallsW_m2_R19,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W_m2_R19,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, +Metal framed wallsW_m3_R21,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W_m3_R21,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, +Metal framed wallsW_T24_2013_R13.99,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W_T24_2013_R13.99,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, +Metal framed wallsW1_R8.60,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W1_R8.60,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, +Metal framed wallsW2_R11.13,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W2_R11.13,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, +Metal framed wallsW3_R11.36,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W3_R11.36,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, +Metal framed wallsW4_R12.62,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W4_R12.62,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, +Typical Insulated Exterior Mass Wall,ExteriorWall,Mass,Typical Insulation,,1IN Stucco,8IN CONCRETE HW RefBldg,Typical Insulation,1/2IN Gypsum,, +Typical Insulated Metal Building Wall,ExteriorWall,Metal Building,Typical Insulation,,Metal Siding,Typical Insulation,1/2IN Gypsum,,, +Typical Insulated Steel Framed Exterior Wall,ExteriorWall,SteelFramed,Typical Insulation,,25mm Stucco,5/8 in. Gypsum Board,Typical Insulation,5/8 in. Gypsum Board,, +Typical Insulated Wood Framed Exterior Wall,ExteriorWall,WoodFramed,Typical Insulation,,25mm Stucco,5/8 in. Gypsum Board,Typical Insulation,5/8 in. Gypsum Board,, +Typical Uninsulated Exterior Mass Wall,ExteriorWall,Mass,,,1IN Stucco,8IN CONCRETE HW RefBldg,1/2IN Gypsum,,, +Typical Uninsulated Metal Building Wall,ExteriorWall,Metal Building,,,Metal Siding,1/2IN Gypsum,,,, +Typical Uninsulated Steel Framed Exterior Wall,ExteriorWall,SteelFramed,,,Wood Siding,1/2IN Gypsum,,,, +WoodWallU110,ExteriorWall,,,,Plywood - 5/8 in.,Compliance Insulation R6.46,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 3/8 in.,, +ASHRAE 189.1-2009 ExtWindow ClimateZone 1,ExteriorWindow,,,,Theoretical Glass [167],,,,, +ASHRAE 189.1-2009 ExtWindow ClimateZone 2,ExteriorWindow,,,,Theoretical Glass [197],,,,, +ASHRAE 189.1-2009 ExtWindow ClimateZone 3,ExteriorWindow,,,,Theoretical Glass [202],,,,, +ASHRAE 189.1-2009 ExtWindow ClimateZone 4-5,ExteriorWindow,,,,Theoretical Glass [207],,,,, +ASHRAE 189.1-2009 ExtWindow ClimateZone 6,ExteriorWindow,,,,Theoretical Glass [216],,,,, +ASHRAE 189.1-2009 ExtWindow ClimateZone 7-8,ExteriorWindow,,,,Theoretical Glass [221],,,,, +ASHRAE 189.1-2009 ExtWindow ClimateZone alt-res 4-5,ExteriorWindow,,,,Theoretical Glass [216],,,,, +U 0.11 SHGC 0.34 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.11 SHGC 0.34 Simple Glazing,,,,, +U 0.11 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.11 SHGC 0.38 Simple Glazing,,,,, +U 0.12 SHGC 0.34 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.12 SHGC 0.34 Simple Glazing,,,,, +U 0.12 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.12 SHGC 0.38 Simple Glazing,,,,, +U 0.13 SHGC 0.32 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.13 SHGC 0.32 Simple Glazing,,,,, +U 0.13 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.13 SHGC 0.38 Simple Glazing,,,,, +U 0.14 SHGC 0.31 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.14 SHGC 0.31 Simple Glazing,,,,, +U 0.14 SHGC 0.34 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.14 SHGC 0.34 Simple Glazing,,,,, +U 0.14 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.14 SHGC 0.36 Simple Glazing,,,,, +U 0.14 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.14 SHGC 0.38 Simple Glazing,,,,, +U 0.15 SHGC 0.31 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.15 SHGC 0.31 Simple Glazing,,,,, +U 0.15 SHGC 0.34 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.15 SHGC 0.34 Simple Glazing,,,,, +U 0.17 SHGC 0.31 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.17 SHGC 0.31 Simple Glazing,,,,, +U 0.17 SHGC 0.32 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.17 SHGC 0.32 Simple Glazing,,,,, +U 0.17 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.17 SHGC 0.36 Simple Glazing,,,,, +U 0.18 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.18 SHGC 0.22 Simple Glazing,,,,, +U 0.18 SHGC 0.24 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.18 SHGC 0.24 Simple Glazing,,,,, +U 0.19 SHGC 0.20 Trp LoE Film (55) Bronze 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,BRONZE 6MM,AIR 13MM,COATED POLY-55,AIR 13MM,CLEAR 3MM, +U 0.20 SHGC 0.19 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.20 SHGC 0.19 Simple Glazing,,,,, +U 0.20 SHGC 0.20 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.20 SHGC 0.20 Simple Glazing,,,,, +U 0.20 SHGC 0.21 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.20 SHGC 0.21 Simple Glazing,,,,, +U 0.20 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.20 SHGC 0.22 Simple Glazing,,,,, +U 0.23 SHGC 0.31 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.23 SHGC 0.31 Simple Glazing,,,,, +U 0.23 SHGC 0.34 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.23 SHGC 0.34 Simple Glazing,,,,, +U 0.24 SHGC 0.11 Dbl LoE Elec Abs Colored 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,ECABS-2 COLORED 6MM,ARGON 13MM,LoE SPEC SEL CLEAR 6MM Rev,,, +U 0.24 SHGC 0.16 Dbl Elec Abs Colored 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,ECABS-2 COLORED 6MM,ARGON 13MM,CLEAR 6MM,,, +U 0.24 SHGC 0.23 Dbl LoE Spec Sel Tint 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,LoE SPEC SEL TINT 6MM,ARGON 13MM,CLEAR 6MM,,, +U 0.25 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.25 SHGC 0.22 Simple Glazing,,,,, +U 0.25 SHGC 0.24 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.25 SHGC 0.24 Simple Glazing,,,,, +U 0.25 SHGC 0.40 Dbl LoE (e2-.1) Tint 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,LoE TINT 6MM,ARGON 13MM,CLEAR 6MM,,, +U 0.26 SHGC 0.40 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.26 SHGC 0.40 Simple Glazing,,,,, +U 0.29 SHGC 0.11 Dbl LoE Elec Ref Colored 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,ECREF-2 COLORED 6MM,AIR 13MM,LoE SPEC SEL CLEAR 6MM Rev,,, +U 0.29 SHGC 0.17 Dbl Elec Abs Colored 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,ECABS-2 COLORED 6MM,AIR 13MM,CLEAR 6MM,,, +U 0.29 SHGC 0.22 Trp LoE Film (55) Bronze 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,BRONZE 6MM,AIR 6MM,COATED POLY-55,AIR 6MM,CLEAR 3MM, +U 0.29 SHGC 0.40 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.29 SHGC 0.40 Simple Glazing,,,,, +U 0.30 SHGC 0.40 Dbl LoE (e2-.1) Tint 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,LoE TINT 6MM,AIR 13MM,CLEAR 6MM,,, +U 0.32 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.32 SHGC 0.36 Simple Glazing,,,,, +U 0.33 SHGC 0.11 Dbl LoE Elec Ref Colored 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,ECREF-2 COLORED 6MM,AIR 13MM,LoE SPEC SEL CLEAR 6MM Rev,,, +U 0.33 SHGC 0.40 Dbl LoE (e2-.1) Tint 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,LoE TINT 6MM,AIR 13MM,CLEAR 6MM,,, +U 0.33 SHGC 0.45 Trp LoE Film (77) Clr 3mm/6mm Air,ExteriorWindow,Metal framing (all other),,,CLEAR 3MM,AIR 6MM,COATED POLY-77,AIR 6MM,CLEAR 3MM, +U 0.34 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.34 SHGC 0.38 Simple Glazing,,,,, +U 0.34 SHGC 0.40 Dbl LoE (e2-.1) Tint 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,LoE TINT 6MM,AIR 13MM,CLEAR 6MM,,, +U 0.34 SHGC 0.45 Dbl LoE (e2-.2) Clr 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,PYR B CLEAR 6MM,AIR 13MM,CLEAR 6MM,,, +U 0.35 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.35 SHGC 0.22 Simple Glazing,,,,, +U 0.35 SHGC 0.24 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.35 SHGC 0.24 Simple Glazing,,,,, +U 0.35 SHGC 0.26 Dbl Ref-C-M Clr 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,REF C CLEAR MID 6MM,ARGON 13MM,CLEAR 6MM,,, +U 0.35 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,LoE TINT 6MM,AIR 13MM,CLEAR 6MM,,, +U 0.36 SHGC 0.35 Dbl LoE Spec Sel Tint 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,LoE SPEC SEL TINT 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.36 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.36 SHGC 0.36 Simple Glazing,,,,, +U 0.36 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.36 SHGC 0.38 Simple Glazing,,,,, +U 0.38 SHGC 0.26 Dbl Ref B-H Tint 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,REF B TINT HI 6MM,ARGON 13MM,CLEAR 6MM,,, +U 0.38 SHGC 0.30 Dbl Ref-B-H Clr 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,ARGON 13MM,CLEAR 6MM,,, +U 0.39 SHGC 0.32,ExteriorWindow,Metal framing (all other),,,Theoretical Glass 347,,,,, +U 0.39 SHGC 0.38,ExteriorWindow,Metal framing (all other),,,Theoretical Glass 297,,,,, +U 0.40 SHGC 0.43 Dbl LoE Spec Sel Clr 3mm/6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,LoE SPEC SEL CLEAR 3MM,AIR 6MM,CLEAR 6MM,,, +U 0.40 SHGC 0.45,ExteriorWindow,Metal framing (all other),,,ECABS-2 BLEACHED 6MM,AIR 6MM,LoE SPEC SEL CLEAR 6MM Rev,,, +U 0.42 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.42 SHGC 0.25 Simple Glazing,,,,, +U 0.42 SHGC 0.34 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.42 SHGC 0.34 Simple Glazing,,,,, +U 0.42 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,LoE TINT 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.42 SHGC 0.40 Dbl LoE (e2-.1) Tint 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,LoE TINT 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.42 SHGC 0.45 Dbl Ref-D Clr 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,REF D CLEAR 6MM,ARGON 13MM,CLEAR 6MM,,, +U 0.43 SHGC 0.26 Dbl Ref-B-H Clr 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,AIR 13MM,CLEAR 6MM,,, +U 0.43 SHGC 0.29 Dbl LoE Spec Sel Tint 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,LoE SPEC SEL TINT 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.44 SHGC 0.20 Dbl Ref-B-H Tint 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,REF B TINT HI 6MM,AIR 13MM,CLEAR 6MM,,, +U 0.44 SHGC 0.26 Dbl Ref-B-H Clr 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,AIR 13MM,CLEAR 6MM,,, +U 0.45 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.45 SHGC 0.25 Simple Glazing,,,,, +U 0.45 SHGC 0.31 Dbl Ref-B-H Clr 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,AIR 13MM,CLEAR 6MM,,, +U 0.45 SHGC 0.33 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.45 SHGC 0.33 Simple Glazing,,,,, +U 0.46 SHGC 0.45 Dbl Grey 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,GREY 6MM,AIR 13MM,CLEAR 6MM,,, +U 0.47 SHGC 0.33 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.47 SHGC 0.33 Simple Glazing,,,,, +U 0.48 SHGC 0.19 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.48 SHGC 0.19 Simple Glazing,,,,, +U 0.48 SHGC 0.21 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.48 SHGC 0.21 Simple Glazing,,,,, +U 0.48 SHGC 0.20 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.48 SHGC 0.20 Simple Glazing,,,,, +U 0.48 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.48 SHGC 0.22 Simple Glazing,,,,, +U 0.48 SHGC 0.40 Dbl Ref-D Clr 6mm/13mm,ExteriorWindow,Metal framing (all other),,,REF D CLEAR 6MM,AIR 13MM,CLEAR 6MM,,, +U 0.50 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.50 SHGC 0.22 Simple Glazing,,,,, +U 0.50 SHGC 0.23 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.50 SHGC 0.23 Simple Glazing,,,,, +U 0.52 SHGC 0.22 Dbl Ref-B-L Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF B CLEAR LO 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.52 SHGC 0.39 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.52 SHGC 0.39 Simple Glazing,,,,, +U 0.52 SHGC 0.40 Dbl Ref-D Clr 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,REF D CLEAR 6MM,AIR 13MM,CLEAR 6MM,,, +U 0.52 SHGC 0.49 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.52 SHGC 0.49 Simple Glazing,,,,, +U 0.52 SHGC 0.615 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.52 SHGC 0.615 Simple Glazing,,,,, +U 0.54 SHGC 0.13 Dbl Ref-A-L Clr 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,REF A CLEAR LO 6MM,AIR 13MM,CLEAR 6MM,,, +U 0.54 SHGC 0.18 Dbl Ref-A-M Tint 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF A TINT MID 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.54 SHGC 0.23 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.54 SHGC 0.23 Simple Glazing,,,,, +U 0.54 SHGC 0.27 Dbl Ref-C-H Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF C CLEAR HI 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.55 SHGC 0.25,ExteriorWindow,Metal framing (all other),,,Glass_2175_LayerAvg,Gap_1_W_0_0032,Glass_2022F_LayerAvg,,, +U 0.55 SHGC 0.31 Dbl Ref-D Tint 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF D TINT 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.56 SHGC 0.35 Dbl Ref-D Tint 6mm/6mm,ExteriorWindow,Metal framing (all other),,,REF D TINT 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.56 SHGC 0.76 Dbl Clr 3mm/6mm Air,ExteriorWindow,Metal framing (all other),,,CLEAR 3MM,AIR 6MM,CLEAR 3MM,,, +U 0.57 SHGC 0.25 Dbl Ref-C-H Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF C CLEAR HI 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF D CLEAR 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,BLUE 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.59 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.59 SHGC 0.36 Simple Glazing,,,,, +U 0.59 SHGC 0.39 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.59 SHGC 0.39 Simple Glazing,,,,, +U 0.60 SHGC 0.23 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.60 SHGC 0.23 Simple Glazing,,,,, +U 0.62 SHGC 0.20 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.62 SHGC 0.20 Simple Glazing,,,,, +U 0.62 SHGC 0.21 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.62 SHGC 0.21 Simple Glazing,,,,, +U 0.62 SHGC 0.25 Dbl Ref-C-H Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF C CLEAR HI 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.62 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF D CLEAR 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.62 SHGC 0.41 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.62 SHGC 0.41 Simple Glazing,,,,, +U 0.62 SHGC 0.49 Dbl Blue 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,BLUE 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.65 SHGC 0.25 Dbl Ref-C-H Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF C CLEAR HI 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.67 SHGC 0.77 Sgl LoE (e2-.2) Clr 3mm,ExteriorWindow,Metal framing (all other),,,PYR B CLEAR 3MM,,,,, +U 0.71 SHGC 0.25 Dbl Ref-C-H Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF C CLEAR HI 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.72 SHGC 0.25 Sgl Ref-B-M Tint 6mm,ExteriorWindow,Metal framing (all other),,,REF B TINT MID 6MM,,,,, +U 0.72 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.72 SHGC 0.25 Simple Glazing,,,,, +U 0.72 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.72 SHGC 0.36 Simple Glazing,,,,, +U 0.72 SHGC 0.39 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.72 SHGC 0.39 Simple Glazing,,,,, +U 0.75 SHGC 0.72 Sgl LoE (e2-.2) Clr 6mm,ExteriorWindow,Metal framing (all other),,,PYR B CLEAR 6MM,,,,, +U 0.88 SHGC 0.16 Sgl Ref-A-L Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF A CLEAR LO 6MM,,,,, +U 0.88 SHGC 0.27 Sgl Elec Ref Colored 6mm,ExteriorWindow,Metal framing (all other),,,ECREF-1 COLORED 6MM,,,,, +U 0.98 SHGC 0.45 Sgl Ref-B-H Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,,,,, +U 0.98 SHGC 0.68 Sgl Ref-B-H Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,,,,, +U 1.17 SHGC 0.39 Sgl Ref-B-H Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,,,,, +U 1.17 SHGC 0.49 Sgl Ref-D Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF D CLEAR 6MM,,,,, +U 1.17 SHGC 0.68 Sgl Green 3mm,ExteriorWindow,Metal framing (all other),,,GREEN 3MM,,,,, +U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm,ExteriorWindow,Metal framing (all other),,,ECREF-1 COLORED 6MM,,,,, +U 1.22 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 1.22 SHGC 0.25 Simple Glazing,,,,, +U 1.22 SHGC 0.34 Sgl Ref-C-H Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF C CLEAR HI 6MM,,,,, +U 1.22 SHGC 0.39 Sgl Ref-B-H Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,,,,, +U 1.22 SHGC 0.54 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 1.22 SHGC 0.54 Simple Glazing,,,,, +U 1.22 SHGC 0.61 Sgl Green 6mm,ExteriorWindow,Metal framing (all other),,,GREEN 6MM,,,,, +U 1.98 SHGC 0.36 Sgl Ref-B-H Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,,,,, +U 1.98 SHGC 0.61 Sgl Green 6mm,ExteriorWindow,Metal framing (all other),,,GREEN 6MM,,,,, +U0.47_SHGC_0.49_SimpleGlazing_Window_05,ExteriorWindow,,,,U0.47_SHGC_0.49_SimpleGlazing_Window_05,,,,, +U0.47_SHGC0.46_SimpleGlazing_Window_07,ExteriorWindow,,,,U0.47_SHGC0.46_SimpleGlazing_Window_07,,,,, +U0.47_SHGC0.47_SimpleGlazing_Window_06,ExteriorWindow,,,,U0.47_SHGC0.47_SimpleGlazing_Window_06,,,,, +U0.47_SHGC0.47_SimpleGlazing_Window_11,ExteriorWindow,,,,U0.47_SHGC0.47_SimpleGlazing_Window_11,,,,, +U0.47_SHGC0.5_SimpleGlazing_Window_03,ExteriorWindow,,,,U0.47_SHGC0.5_SimpleGlazing_Window_03,,,,, +U0.77_SHGC_0.77_SimpleGlazing_Window_02,ExteriorWindow,,,,U0.77_SHGC_0.77_SimpleGlazing_Window_02,,,,, +U0.77_SHGC0.5_SimpleGlazing_Window_09,ExteriorWindow,,,,U0.77_SHGC0.5_SimpleGlazing_Window_09,,,,, +U0.77_SHGC0.61_SimpleGlazing_Window_08,ExteriorWindow,,,,U0.77_SHGC0.61_SimpleGlazing_Window_08,,,,, +U0.77_SHGC0.62_SimpleGlazing_Window_04,ExteriorWindow,,,,U0.77_SHGC0.62_SimpleGlazing_Window_04,,,,, +U1.23_SHGC0.5_SimpleGlazing_Window_12,ExteriorWindow,,,,U1.23_SHGC0.5_SimpleGlazing_Window_12,,,,, +U1.23_SHGC0.82_SimpleGlazing_Window_01,ExteriorWindow,,,,U1.23_SHGC0.82_SimpleGlazing_Window_01,,,,, +U1.23_SHGC0.82_SimpleGlazing_Window_10,ExteriorWindow,,,,U1.23_SHGC0.82_SimpleGlazing_Window_10,,,,, +Adiabatic GroundContactFloor,GroundContactFloor,Mass,,,Adiabatic Material,,,,, +ext-slab,GroundContactFloor,Mass,,,6 in. Normalweight Concrete Floor,,,,, +ext-slab-mass,GroundContactFloor,Mass,CP02 CARPET PAD,,HW CONCRETE,CP02 CARPET PAD,,,, +ext-slab-metal-building,GroundContactFloor,Metal Building,,,HW CONCRETE 8 in,,,,, +ext-slab-steel-frame,GroundContactFloor,SteelFramed,CP02 CARPET PAD,,HW CONCRETE 8 in,CP02 CARPET PAD,,,, +Ground FloorGround_Floor_R11_T2013,GroundContactFloor,,,,Ground_Floor_R11_T2013,Plywood - 5/8 in. CBES,Carpet - 3/4 in. CBES,,, +Ground FloorGround_Floor_R17_T2013,GroundContactFloor,,,,Ground_Floor_R17_T2013,Plywood - 5/8 in. CBES,Carpet - 3/4 in. CBES,,, +Ground FloorGround_Floor_R22_T2013,GroundContactFloor,,,,Ground_Floor_R22_T2013,Plywood - 5/8 in. CBES,Carpet - 3/4 in. CBES,,, +Smallhotel 2010 Slab Floor,GroundContactFloor,Mass,Typical Insulation,,8 in. Normalweight Concrete Floor,CP02 CARPET PAD,,,, +Typical Carpeted 6in Slab Floor,GroundContactFloor,Mass,,,6 in. Normalweight Concrete Floor,Typical Carpet Pad,,,, +Typical Carpeted 8in Slab Floor,GroundContactFloor,Mass,,,8 in. Normalweight Concrete Floor,Typical Carpet Pad,,,, +Typical Insulated 6in Slab Floor,GroundContactFloor,Mass,Typical Insulation,,Typical Insulation,6 in. Normalweight Concrete Floor,,,, +Typical Insulated 8in Slab Floor,GroundContactFloor,Mass,Typical Insulation,,Typical Insulation,8 in. Normalweight Concrete Floor,,,, +Typical Insulated Carpeted 6in Slab Floor,GroundContactFloor,Mass,Typical Insulation,,Typical Insulation,6 in. Normalweight Concrete Floor,Typical Carpet Pad,,, +Typical Insulated Carpeted 8in Slab Floor,GroundContactFloor,Mass,Typical Insulation,,Typical Insulation,8 in. Normalweight Concrete Floor,Typical Carpet Pad,,, +Typical Uncarpeted 6in Slab Floor,GroundContactFloor,Mass,,,6 in. Normalweight Concrete Floor,,,,, +Typical Uninsulated 6in Slab Floor,GroundContactFloor,Mass,,,6 in. Normalweight Concrete Floor,,,,, +Typical Uninsulated 8in Slab Floor,GroundContactFloor,Mass,,,8 in. Normalweight Concrete Floor,,,,, +Typical Uninsulated Carpeted 8in Slab Floor,GroundContactFloor,Mass,,,8 in. Concrete Block Basement Wall,Typical Carpet Pad,,,, +Typical Unisulated Carpeted 6in Slab Floor,GroundContactFloor,Mass,,,6 in. Normalweight Concrete Floor,Typical Carpet Pad,,,, +Typical Insulated Basement Mass Wall,GroundContactWall,Mass,Typical Insulation,,Typical Insulation,8 in. Concrete Block Basement Wall,,,, +Typical Uninsulated Basement Mass Wall,GroundContactWall,Mass,,,8 in. Concrete Block Basement Wall,,,,, +ceiling_Metal roof,InteriorCeiling,,,,Metal Standing Seam - 1/16 in.,ceiling_2_Insulation,,,, +int_slab_ceiling_smallhotel,InteriorCeiling,,,,CP02 CARPET PAD,4 in. Normalweight Concrete Floor,,,, +LargeHotel Interior Ceiling,InteriorCeiling,,,,CP02 CARPET PAD,100mm Normalweight concrete floor,Nonres_Floor_Insulation,G01 13mm gypsum board,, +NACM_Drop Ceiling,InteriorCeiling,,,,Acoustic Ceiling,,,,, +Plenum Acoustical Tile,InteriorCeiling,,,,Acoustic Tile - 1/2 in.,,,,, +Typical Interior Ceiling,InteriorCeiling,,,,CP02 CARPET PAD,100mm Normalweight concrete floor,,,, +Typical Interior Door,InteriorDoor,,,,G05 25mm wood,,,,, +int_slab_floor_smallhotel,InteriorFloor,,,,4 in. Normalweight Concrete Floor,CP02 CARPET PAD,,,, +LargeHotel Interior Floor,InteriorFloor,,,,G01 13mm gypsum board,Nonres_Floor_Insulation,100mm Normalweight concrete floor,CP02 CARPET PAD,, +NACM_Interior Floor,InteriorFloor,,,,NACM_Carpet 3/4in,,,,, +Typical Interior Floor,InteriorFloor,,,,100mm Normalweight concrete floor,CP02 CARPET PAD,,,, +Typical Interior Slab Floor,InteriorFloor,Mass,,,4 in. Normalweight Concrete Floor,Typical Carpet Pad,,,, +Typical Interior Partition,InteriorPartition,,,,G05 25mm wood,,,,, +Uninsulated Steel Stud Wall,InteriorPartition,SteelFramed,,,Metal Framed Wall - 24inOC - 2x4 - R0 ins.,,,,, +int_wall_smallhotel,InteriorWall,,,,1/2 in. Gypsum Board,1/2 in. Gypsum Board,,,, +LargeHotel Interior Wall,InteriorWall,,,,G01 13mm gypsum board,G01 13mm gypsum board,,,, +NACM_Interior Wall,InteriorWall,,,,NACM_Gypsum Board 5/8in,NACM_Gypsum Board 5/8in,,,, +Typical Insulated Interior Wall,InteriorWall,WoodFramed,Typical Insulation,,25mm Stucco,5/8 in. Gypsum Board,Typical Insulation,Steel Frame/Cavity,5/8 in. Gypsum Board, +Typical Interior Wall,InteriorWall,,,,G01 13mm gypsum board,G01 13mm gypsum board,,,, +Typical Uninsulated Interior Wall,InteriorWall,WoodFramed,,,1/2 in. Gypsum Board,1/2 in. Gypsum Board,,,, +Typical Interior Window,InteriorWindow,,,,CLEAR 3MM,,,,, +U 0.58 SHGC 0.19 Simple Glazing Skylight,Skylight,Glass with Curb,,,U 0.58 SHGC 0.19 Simple Glazing,,,,, +U 0.58 SHGC 0.36 Simple Glazing Skylight,Skylight,Glass with Curb,,,U 0.58 SHGC 0.36 Simple Glazing,,,,, +U 1.98 SHGC 0.61 Simple Glazing Skylight,Skylight,Glass with Curb,,,U 1.98 SHGC 0.61 Simple Glazing,,,,, +Window_U_0.50_SHGC_0.40_Skylight_Frame_Width_0.000_in,Skylight,,,Skylight_Frame_Width_0.000_in,Glass_2052_LayerAvg,Gap_1_W_0_0038,Glass_2027F_LayerAvg,,, +Window_U_0.50_SHGC_0.40_Skylight_Frame_Width_0.334_in,Skylight,,,Skylight_Frame_Width_0.334_in,Glass_2052_LayerAvg,Gap_1_W_0_0038,Glass_2027F_LayerAvg,,, +Window_U_0.50_SHGC_0.40_Skylight_Frame_Width_0.430_in,Skylight,,,Skylight_Frame_Width_0.430_in,Glass_2052_LayerAvg,Gap_1_W_0_0038,Glass_2027F_LayerAvg,,, +Window_U_0.55_SHGC_0.35_Skylight_Frame_Width_0.709_in,Skylight,,,Skylight_Frame_Width_0.709_in,Glass_2052_LayerAvg,Gap_1_W_0_0038,Glass_2027F_LayerAvg,,, +Window_U_0.65_SHGC_0.35_Skylight_Frame_Width_2.339_in,Skylight,,,Skylight_Frame_Width_2.339_in,Glass_2052_LayerAvg,Gap_1_W_0_0024,Glass_2027F_LayerAvg,,, +Window_U_0.75_SHGC_0.35_Skylight_Frame_Width_2.339_in,Skylight,,,Skylight_Frame_Width_2.339_in,Glass_2052_LayerAvg,Gap_1_W_0_0018,Glass_2027F_LayerAvg,,, +U 0.60 SHGC 0.25 Dbl 2.5mm air,,,,,Glass_2175_LayerAvg,Gap_1_W_0_0025,Glass_2022F_LayerAvg,,, +U 0.61 SHGC 0.77 Simple Glazing Skylight,,,,,U 0.61 SHGC 0.77 Simple Glazing,,,,, +U 0.65 SHGC 0.35 Simple Glazing Skylight,,,,,U 0.65 SHGC 0.35 Simple Glazing,,,,, +U 0.69 SHGC 0.19 Simple Glazing Skylight,,,,,U 0.69 SHGC 0.19 Simple Glazing,,,,, +U 0.69 SHGC 0.36 Simple Glazing Skylight,,,,,U 0.69 SHGC 0.36 Simple Glazing,,,,, +U 0.69 SHGC 0.39 Simple Glazing Skylight,,,,,U 0.69 SHGC 0.39 Simple Glazing,,,,, +U 0.69 SHGC 0.49 Simple Glazing Skylight,,,,,U 0.69 SHGC 0.49 Simple Glazing,,,,, +U 0.69 SHGC 0.64 Simple Glazing Skylight,,,,,U 0.69 SHGC 0.64 Simple Glazing,,,,, +U 0.69 SHGC 0.68 Simple Glazing Skylight,,,,,U 0.69 SHGC 0.68 Simple Glazing,,,,, +U 0.74 SHGC 0.55 Simple Glazing Skylight,,,,,U 0.74 SHGC 0.55 Simple Glazing,,,,, +U 0.74 SHGC 0.65 Simple Glazing Skylight,,,,,U 0.74 SHGC 0.65 Simple Glazing,,,,, +U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,,U 0.75 SHGC 0.35 Simple Glazing,,,,, +U 0.81 SHGC 0.65 Simple Glazing Skylight,,,,,U 0.81 SHGC 0.65 Simple Glazing,,,,, +U 0.85 SHGC 0.65 Simple Glazing Skylight,,,,,U 0.85 SHGC 0.65 Simple Glazing,,,,, +U 0.87 SHGC 0.58 Simple Glazing Skylight,,,,,U 0.87 SHGC 0.58 Simple Glazing,,,,, +U 0.87 SHGC 0.71 Simple Glazing Skylight,,,,,U 0.87 SHGC 0.71 Simple Glazing,,,,, +U 0.87 SHGC 0.77 Simple Glazing Skylight,,,,,U 0.87 SHGC 0.77 Simple Glazing,,,,, +U 0.98 SHGC 0.19 Simple Glazing Skylight,,,,,U 0.98 SHGC 0.19 Simple Glazing,,,,, +U 0.98 SHGC 0.36 Simple Glazing Skylight,,,,,U 0.98 SHGC 0.36 Simple Glazing,,,,, +U 1.10 SHGC 0.62 Simple Glazing Skylight,,,,,U 1.10 SHGC 0.62 Simple Glazing,,,,, +U 1.10 SHGC 0.77 Simple Glazing Skylight,,,,,U 1.10 SHGC 0.77 Simple Glazing,,,,, +U 1.15 SHGC 0.77 Simple Glazing Skylight,,,,,U 1.15 SHGC 0.77 Simple Glazing,,,,, +U 1.17 SHGC 0.19 Simple Glazing Skylight,,,,,U 1.17 SHGC 0.19 Simple Glazing,,,,, +U 1.17 SHGC 0.36 Simple Glazing Skylight,,,,,U 1.17 SHGC 0.36 Simple Glazing,,,,, +U 1.17 SHGC 0.39 Simple Glazing Skylight,,,,,U 1.17 SHGC 0.39 Simple Glazing,,,,, +U 1.17 SHGC 0.49 Simple Glazing Skylight,,,,,U 1.17 SHGC 0.49 Simple Glazing,,,,, +U 1.17 SHGC 0.64 Simple Glazing Skylight,,,,,U 1.17 SHGC 0.64 Simple Glazing,,,,, +U 1.17 SHGC 0.68 Simple Glazing Skylight,,,,,U 1.17 SHGC 0.68 Simple Glazing,,,,, +U 1.30 SHGC 0.27 Simple Glazing Skylight,,,,,U 1.30 SHGC 0.27 Simple Glazing,,,,, +U 1.30 SHGC 0.34 Simple Glazing Skylight,,,,,U 1.30 SHGC 0.34 Simple Glazing,,,,, +U 1.30 SHGC 0.62 Simple Glazing Skylight,,,,,U 1.30 SHGC 0.62 Simple Glazing,,,,, +U 1.30 SHGC 0.65 Simple Glazing Skylight,,,,,U 1.30 SHGC 0.65 Simple Glazing,,,,, +U 1.36 SHGC 0.19 Simple Glazing Skylight,,,,,U 1.36 SHGC 0.19 Simple Glazing,,,,, +U 1.36 SHGC 0.36 Simple Glazing Skylight,,,,,U 1.36 SHGC 0.36 Simple Glazing,,,,, +U 1.36 SHGC 0.39 Simple Glazing Skylight,,,,,U 1.36 SHGC 0.39 Simple Glazing,,,,, +U 1.36 SHGC 0.61 Simple Glazing Skylight,,,,,U 1.36 SHGC 0.61 Simple Glazing,,,,, +U 1.70 SHGC 0.36 Simple Glazing Skylight,,,,,U 1.70 SHGC 0.36 Simple Glazing,,,,, +U 1.80 SHGC 0.36 Simple Glazing Skylight,,,,,U 1.80 SHGC 0.36 Simple Glazing,,,,, +U 1.90 SHGC 0.27 Simple Glazing Skylight,,,,,U 1.90 SHGC 0.27 Simple Glazing,,,,, +U 1.90 SHGC 0.34 Simple Glazing Skylight,,,,,U 1.90 SHGC 0.34 Simple Glazing,,,,, +U 1.90 SHGC 0.39 Simple Glazing Skylight,,,,,U 1.90 SHGC 0.39 Simple Glazing,,,,, +U 1.90 SHGC 0.65 Simple Glazing Skylight,,,,,U 1.90 SHGC 0.65 Simple Glazing,,,,, +U 1.98 SHGC 0.16 Simple Glazing Skylight,,,,,U 1.98 SHGC 0.16 Simple Glazing,,,,, +U 1.98 SHGC 0.19 Simple Glazing Skylight,,,,,U 1.98 SHGC 0.19 Simple Glazing,,,,, +U 1.98 SHGC 0.36 Simple Glazing Skylight,,,,,U 1.98 SHGC 0.36 Simple Glazing,,,,, +U 1.98 SHGC 0.39 Simple Glazing Skylight,,,,,U 1.98 SHGC 0.39 Simple Glazing,,,,, +U 0.49 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.49 SHGC 0.22 Simple Glazing,,,,, +U 0.57 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.57 SHGC 0.25 Simple Glazing,,,,, +U 0.53 SHGC 0.25 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.53 SHGC 0.25 Simple Glazing,,,,, +U 0.48 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.48 SHGC 0.25 Simple Glazing,,,,, +U 0.38 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.38 SHGC 0.36 Simple Glazing,,,,, +U 0.38 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.38 SHGC 0.38 Simple Glazing,,,,, +U 0.36 SHGC 0.4 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.36 SHGC 0.4 Simple Glazing,,,,, +U 0.33 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.33 SHGC 0.45 Simple Glazing,,,,, +U 0.29 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.29 SHGC 0.45 Simple Glazing,,,,, +U 0.5 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.5 SHGC 0.22 Simple Glazing,,,,, +U 0.54 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.54 SHGC 0.25 Simple Glazing,,,,, +U 0.49 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.49 SHGC 0.25 Simple Glazing,,,,, +U 0.45 SHGC 0.25 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.45 SHGC 0.25 Simple Glazing,,,,, +U 1.19 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 1.19 SHGC 0.45 Simple Glazing,,,,, +U 0.73 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.73 SHGC 0.45 Simple Glazing,,,,, +U 0.62 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.62 SHGC 0.45 Simple Glazing,,,,, +U 0.51 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.51 SHGC 0.45 Simple Glazing,,,,, +U 0.38 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.38 SHGC 0.45 Simple Glazing,,,,, +U 0.53 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.53 SHGC 0.22 Simple Glazing,,,,, +U 0.53 SHGC 0.23 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.53 SHGC 0.23 Simple Glazing,,,,, +U 0.38 SHGC 0.35 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.38 SHGC 0.35 Simple Glazing,,,,, +U 0.38 SHGC 0.37 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.38 SHGC 0.37 Simple Glazing,,,,, +U 0.36 SHGC 0.37 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.36 SHGC 0.37 Simple Glazing,,,,, +U 0.31 SHGC 0.39 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.31 SHGC 0.39 Simple Glazing,,,,, +U 0.28 SHGC 0.39 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.28 SHGC 0.39 Simple Glazing,,,,, +U 0.51 SHGC 0.22 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.51 SHGC 0.22 Simple Glazing,,,,, +U 0.51 SHGC 0.23 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.51 SHGC 0.23 Simple Glazing,,,,, +U 0.46 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.46 SHGC 0.25 Simple Glazing,,,,, +U 0.43 SHGC 0.25 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.43 SHGC 0.25 Simple Glazing,,,,, +U 0.36 SHGC 0.36 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.36 SHGC 0.36 Simple Glazing,,,,, +U 0.36 SHGC 0.38 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.36 SHGC 0.38 Simple Glazing,,,,, +U 0.34 SHGC 0.38 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.34 SHGC 0.38 Simple Glazing,,,,, +U 0.29 SHGC 0.4 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.29 SHGC 0.4 Simple Glazing,,,,, +U 0.26 SHGC 0.4 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.26 SHGC 0.4 Simple Glazing,,,,, +U 0.37 SHGC 0.36 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.37 SHGC 0.36 Simple Glazing,,,,, +U 0.37 SHGC 0.38 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.37 SHGC 0.38 Simple Glazing,,,,, +U 0.35 SHGC 0.38 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.35 SHGC 0.38 Simple Glazing,,,,, +U 0.3 SHGC 0.4 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.3 SHGC 0.4 Simple Glazing,,,,, +U 0.27 SHGC 0.4 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.27 SHGC 0.4 Simple Glazing,,,,, +U 0.5 SHGC 0.23 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.5 SHGC 0.23 Simple Glazing,,,,, +U 0.42 SHGC 0.25 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.42 SHGC 0.25 Simple Glazing,,,,, +U 0.47 SHGC 0.25 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.47 SHGC 0.25 Simple Glazing,,,,, +U 1.2 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 1.2 SHGC 0.45 Simple Glazing,,,,, +U 0.5 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.5 SHGC 0.45 Simple Glazing,,,,, +U 0.39 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.39 SHGC 0.45 Simple Glazing,,,,, +U 0.36 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.36 SHGC 0.45 Simple Glazing,,,,, +U 0.75 SHGC 0.35 Simple Glazing Window,Skylight,Weighted,,,U 0.75 SHGC 0.35 Simple Glazing Window,,,,, +U 0.65 SHGC 0.35 Simple Glazing Window,Skylight,Weighted,,,U 0.65 SHGC 0.35 Simple Glazing Window,,,,, +U 0.55 SHGC 0.35 Simple Glazing Window,Skylight,Weighted,,,U 0.55 SHGC 0.35 Simple Glazing,,,,, +U 0.5 SHGC 0.4 Simple Glazing Window,Skylight,Weighted,,,U 0.5 SHGC 0.4 Simple Glazing,,,,, +U 0.5 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 0.5 SHGC 0.55 Simple Glazing,,,,, +U 0.41 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 0.41 SHGC 0.55 Simple Glazing,,,,, +U 1.8 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 1.8 SHGC 0.55 Simple Glazing,,,,, +U 1.7 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 1.7 SHGC 0.55 Simple Glazing,,,,, +U 1.15 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 1.15 SHGC 0.55 Simple Glazing,,,,, +U 0.98 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 0.98 SHGC 0.55 Simple Glazing,,,,, +U 0.85 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 0.85 SHGC 0.55 Simple Glazing,,,,, +U 0.7 SHGC 0.3 Simple Glazing Window,Skylight,Weighted,,,U 0.7 SHGC 0.3 Simple Glazing,,,,, +U 0.65 SHGC 0.3 Simple Glazing Window,Skylight,Weighted,,,U 0.65 SHGC 0.3 Simple Glazing,,,,, +U 0.55 SHGC 0.3 Simple Glazing Window,Skylight,Weighted,,,U 0.55 SHGC 0.3 Simple Glazing,,,,, +U 0.47 SHGC 0.4 Simple Glazing Window,Skylight,Weighted,,,U 0.47 SHGC 0.4 Simple Glazing,,,,, +U 0.44 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 0.44 SHGC 0.55 Simple Glazing,,,,, +U 0.9 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 0.9 SHGC 0.55 Simple Glazing,,,,, +U 0.75 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 0.75 SHGC 0.55 Simple Glazing,,,,, +U 0.37 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.37 SHGC 0.25 Simple Glazing,,,,, +U 0.83 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.83 SHGC 0.25 Simple Glazing,,,,, +U 0.77 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.77 SHGC 0.25 Simple Glazing,,,,, +U 0.93 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.93 SHGC 0.45 Simple Glazing,,,,, +U 0.83 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.83 SHGC 0.45 Simple Glazing,,,,, +U 0.65 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 0.65 SHGC 0.55 Simple Glazing,,,,, +U 1.8 SHGC 0.77 Simple Glazing Skylight,Skylight,Weighted,,,U 1.8 SHGC 0.77 Simple Glazing,,,,, +U 0.65 SHGC 0.77 Simple Glazing Skylight,Skylight,Weighted,,,U 0.65 SHGC 0.77 Simple Glazing,,,,, +U 1.8 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 1.8 SHGC 0.55 Simple Glazing,,,,, +U 0.65 SHGC 0.68 Simple Glazing Skylight,Skylight,Weighted,,,U 0.65 SHGC 0.68 Simple Glazing,,,,, +U 1.8 SHGC 0.64 Simple Glazing Skylight,Skylight,Weighted,,,U 1.8 SHGC 0.64 Simple Glazing,,,,, +U 0.33 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.33 SHGC 0.25 Simple Glazing,,,,, +U 0.68 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.68 SHGC 0.25 Simple Glazing,,,,, +U 0.87 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.87 SHGC 0.45 Simple Glazing,,,,, +U 0.77 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.77 SHGC 0.45 Simple Glazing,,,,, +U 0.55 SHGC 0.64 Simple Glazing Skylight,Skylight,Weighted,,,U 0.55 SHGC 0.64 Simple Glazing,,,,, +U 0.55 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 0.55 SHGC 0.55 Simple Glazing,,,,, +U 1.7 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 1.7 SHGC 0.55 Simple Glazing,,,,, +U 0.31 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.31 SHGC 0.36 Simple Glazing,,,,, +U 0.68 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.68 SHGC 0.36 Simple Glazing,,,,, +U 0.5 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 0.5 SHGC 0.55 Simple Glazing,,,,, +U 1.15 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 1.15 SHGC 0.55 Simple Glazing,,,,, +U 0.31 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.31 SHGC 0.38 Simple Glazing,,,,, +U 0.68 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.68 SHGC 0.38 Simple Glazing,,,,, +U 0.45 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.45 SHGC 0.45 Simple Glazing,,,,, +U 0.5 SHGC 0.36 Simple Glazing Skylight,Skylight,Weighted,,,U 0.5 SHGC 0.36 Simple Glazing,,,,, +U 0.5 SHGC 0.19 Simple Glazing Skylight,Skylight,Weighted,,,U 0.5 SHGC 0.19 Simple Glazing,,,,, +U 0.98 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 0.98 SHGC 0.55 Simple Glazing,,,,, +U 0.5 SHGC 0.34 Simple Glazing Skylight,Skylight,Weighted,,,U 0.5 SHGC 0.34 Simple Glazing,,,,, +U 0.98 SHGC 0.27 Simple Glazing Skylight,Skylight,Weighted,,,U 0.98 SHGC 0.27 Simple Glazing,,,,, +U 0.68 SHGC 0.4 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.68 SHGC 0.4 Simple Glazing,,,,, +U 0.85 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 0.85 SHGC 0.55 Simple Glazing,,,,, +U 0.85 SHGC 0.19 Simple Glazing Skylight,Skylight,Weighted,,,U 0.85 SHGC 0.19 Simple Glazing,,,,, +U 0.85 SHGC 0.39 Simple Glazing Skylight,Skylight,Weighted,,,U 0.85 SHGC 0.39 Simple Glazing,,,,, +U 0.28 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.28 SHGC 0.45 Simple Glazing,,,,, +U 0.68 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.68 SHGC 0.45 Simple Glazing,,,,, +U 0.32 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.32 SHGC 0.45 Simple Glazing,,,,, +U 0.5 SHGC 0.27 Simple Glazing Skylight,Skylight,Weighted,,,U 0.5 SHGC 0.27 Simple Glazing,,,,, +U 0.25 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.25 SHGC 0.45 Simple Glazing,,,,, +U 0.5 SHGC 0.39 Simple Glazing Skylight,Skylight,Weighted,,,U 0.5 SHGC 0.39 Simple Glazing,,,,, +U 0.5 SHGC 0.65 Simple Glazing Skylight,Skylight,Weighted,,,U 0.5 SHGC 0.65 Simple Glazing,,,,, +U 0.85 SHGC 0.27 Simple Glazing Skylight,Skylight,Weighted,,,U 0.85 SHGC 0.27 Simple Glazing,,,,, +U 0.5 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.5 SHGC 0.25 Simple Glazing,,,,, +U 1.1 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 1.1 SHGC 0.25 Simple Glazing,,,,, +U 1.1 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 1.1 SHGC 0.45 Simple Glazing,,,,, +U 0.75 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 0.75 SHGC 0.55 Simple Glazing,,,,, +U 0.75 SHGC 0.49 Simple Glazing Skylight,Skylight,Weighted,,,U 0.75 SHGC 0.49 Simple Glazing,,,,, +U 1.8 SHGC 0.49 Simple Glazing Skylight,Skylight,Weighted,,,U 1.8 SHGC 0.49 Simple Glazing,,,,, +U 0.75 SHGC 0.39 Simple Glazing Skylight,Skylight,Weighted,,,U 0.75 SHGC 0.39 Simple Glazing,,,,, +U 0.75 SHGC 0.68 Simple Glazing Skylight,Skylight,Weighted,,,U 0.75 SHGC 0.68 Simple Glazing,,,,, +U 0.75 SHGC 0.64 Simple Glazing Skylight,Skylight,Weighted,,,U 0.75 SHGC 0.64 Simple Glazing,,,,, +U 0.77 SHGC 0.23 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.77 SHGC 0.23 Simple Glazing,,,,, +U 0.68 SHGC 0.23 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.68 SHGC 0.23 Simple Glazing,,,,, +U 0.63 SHGC 0.33 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.63 SHGC 0.33 Simple Glazing,,,,, +U 0.63 SHGC 0.34 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.63 SHGC 0.34 Simple Glazing,,,,, +U 0.63 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.63 SHGC 0.36 Simple Glazing,,,,, +U 0.63 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.63 SHGC 0.45 Simple Glazing,,,,, +U 0.55 SHGC 0.35 Simple Glazing Skylight,Skylight,,,,U 0.55 SHGC 0.35 Simple Glazing,,,,, +U 0.5 SHGC 0.4 Simple Glazing Skylight,Skylight,,,,U 0.5 SHGC 0.4 Simple Glazing,,,,, +U 0.41 SHGC 0.55 Simple Glazing Skylight,Skylight,,,,U 0.41 SHGC 0.55 Simple Glazing,,,,, +U 0.6 SHGC 0.23 Simple Glazing Window,ExteriorWindow,,,,U 0.6 SHGC 0.23 Simple Glazing,,,,, +U 0.65 SHGC 0.3 Simple Glazing Skylight,Skylight,,,,U 0.65 SHGC 0.3 Simple Glazing,,,,, +U 0.55 SHGC 0.3 Simple Glazing Skylight,Skylight,,,,U 0.55 SHGC 0.3 Simple Glazing,,,,, +U 0.47 SHGC 0.4 Simple Glazing Skylight,Skylight,,,,U 0.47 SHGC 0.4 Simple Glazing,,,,, +U 0.44 SHGC 0.55 Simple Glazing Skylight,Skylight,,,,U 0.44 SHGC 0.55 Simple Glazing,,,,, +U 0.83 SHGC 0.21 Simple Glazing Window,ExteriorWindow,,,,U 0.83 SHGC 0.21 Simple Glazing,,,,, +U 0.7 SHGC 0.3 Simple Glazing Skylight,Skylight,,,,U 0.7 SHGC 0.3 Simple Glazing,,,,, +U 0.32 SHGC 0.22 Simple Glazing Window,ExteriorWindow,,,,U 0.32 SHGC 0.22 Simple Glazing,,,,, +U 0.83 SHGC 0.22 Simple Glazing Window,ExteriorWindow,,,,U 0.83 SHGC 0.22 Simple Glazing,,,,, +U 0.83 SHGC 0.2 Simple Glazing Window,ExteriorWindow,,,,U 0.83 SHGC 0.2 Simple Glazing,,,,, +U 0.62 SHGC 0.2 Simple Glazing Window,ExteriorWindow,,,,U 0.62 SHGC 0.2 Simple Glazing,,,,, +U 1.22 SHGC 0.19 Simple Glazing Window,ExteriorWindow,,,,U 1.22 SHGC 0.19 Simple Glazing,,,,, +U 1.22 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 1.22 SHGC 0.45 Simple Glazing,,,,, +U 1.22 SHGC 0.17 Simple Glazing Window,ExteriorWindow,,,,U 1.22 SHGC 0.17 Simple Glazing,,,,, +U 1.22 SHGC 0.39 Simple Glazing Window,ExteriorWindow,,,,U 1.22 SHGC 0.39 Simple Glazing,,,,, +U 0.98 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.98 SHGC 0.45 Simple Glazing,,,,, +U 1.98 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 1.98 SHGC 0.45 Simple Glazing,,,,, +U 0.57 SHGC 0.39 Simple Glazing Window,ExteriorWindow,,,,U 0.57 SHGC 0.39 Simple Glazing,,,,, +U 0.46 SHGC 0.19 Simple Glazing Window,ExteriorWindow,,,,U 0.46 SHGC 0.19 Simple Glazing,,,,, +U 1.98 SHGC 0.34 Simple Glazing Skylight,Skylight,,,,U 1.98 SHGC 0.34 Simple Glazing,,,,, +U 1.22 SHGC 0.61 Simple Glazing Window,ExteriorWindow,,,,U 1.22 SHGC 0.61 Simple Glazing,,,,, +U 1.22 SHGC 0.34 Simple Glazing Window,ExteriorWindow,,,,U 1.22 SHGC 0.34 Simple Glazing,,,,, +U 0.57 SHGC 0.49 Simple Glazing Window,ExteriorWindow,,,,U 0.57 SHGC 0.49 Simple Glazing,,,,, +U 0.46 SHGC 0.26 Simple Glazing Window,ExteriorWindow,,,,U 0.46 SHGC 0.26 Simple Glazing,,,,, +U 0.98 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 0.98 SHGC 0.45 Simple Glazing,,,,, +U 1.98 SHGC 0.65 Simple Glazing Skylight,Skylight,,,,U 1.98 SHGC 0.65 Simple Glazing,,,,, +U 0.58 SHGC 0.61 Simple Glazing Skylight,Skylight,,,,U 0.58 SHGC 0.61 Simple Glazing,,,,, +U 0.46 SHGC 0.36 Simple Glazing Window,ExteriorWindow,,,,U 0.46 SHGC 0.36 Simple Glazing,,,,, +U 0.46 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.46 SHGC 0.45 Simple Glazing,,,,, +U 0.35 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.35 SHGC 0.45 Simple Glazing,,,,, +U 0.98 SHGC 0.62 Simple Glazing Skylight,Skylight,,,,U 0.98 SHGC 0.62 Simple Glazing,,,,, +U 0.58 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 0.58 SHGC 0.45 Simple Glazing,,,,, +U 0.75 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.75 SHGC 0.25 Simple Glazing,,,,, +U 0.7 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.7 SHGC 0.25 Simple Glazing,,,,, +U 1.98 SHGC 0.49 Simple Glazing Skylight,Skylight,,,,U 1.98 SHGC 0.49 Simple Glazing,,,,, +U 0.65 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.65 SHGC 0.25 Simple Glazing,,,,, +U 0.6 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.6 SHGC 0.25 Simple Glazing,,,,, +U 0.9 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.9 SHGC 0.25 Simple Glazing,,,,, +U 1.98 SHGC 0.71 Simple Glazing Skylight,Skylight,,,,U 1.98 SHGC 0.71 Simple Glazing,,,,, +U 0.4 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.4 SHGC 0.4 Simple Glazing,,,,, +U 0.55 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.55 SHGC 0.4 Simple Glazing,,,,, +U 0.85 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.85 SHGC 0.4 Simple Glazing,,,,, +U 0.35 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.35 SHGC 0.4 Simple Glazing,,,,, +U 0.45 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.45 SHGC 0.4 Simple Glazing,,,,, +U 0.8 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.8 SHGC 0.4 Simple Glazing,,,,, +U 0.65 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.65 SHGC 0.45 Simple Glazing,,,,, +U 0.6 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.6 SHGC 0.45 Simple Glazing,,,,, +U 0.9 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.9 SHGC 0.45 Simple Glazing,,,,, +U 0.4 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.4 SHGC 0.45 Simple Glazing,,,,, +U 0.8 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.8 SHGC 0.45 Simple Glazing,,,,, +U 1.2 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 1.2 SHGC 0.25 Simple Glazing,,,,, +U 1.98 SHGC 0.27 Simple Glazing Skylight,Skylight,,,,U 1.98 SHGC 0.27 Simple Glazing,,,,, +U 1.17 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 1.17 SHGC 0.45 Simple Glazing,,,,, +U 0.98 SHGC 0.49 Simple Glazing Skylight,Skylight,,,,U 0.98 SHGC 0.49 Simple Glazing,,,,, +U 0.98 SHGC 0.46 Simple Glazing Skylight,Skylight,,,,U 0.98 SHGC 0.46 Simple Glazing,,,,, +U 0.58 SHGC 0.65 Simple Glazing Skylight,Skylight,,,,U 0.58 SHGC 0.65 Simple Glazing,,,,, +U 0.58 SHGC 0.55 Simple Glazing Skylight,Skylight,,,,U 0.58 SHGC 0.55 Simple Glazing,,,,, +U 0.4 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.4 SHGC 0.25 Simple Glazing,,,,, +U 0.65 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 0.65 SHGC 0.45 Simple Glazing,,,,, +U 0.35 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.35 SHGC 0.25 Simple Glazing,,,,, +U 0.55 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 0.55 SHGC 0.45 Simple Glazing,,,,, +U 0.42 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.42 SHGC 0.4 Simple Glazing,,,,, +U 0.77 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.77 SHGC 0.4 Simple Glazing,,,,, +U 0.81 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.81 SHGC 0.45 Simple Glazing,,,,, +U 0.5 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 0.5 SHGC 0.45 Simple Glazing,,,,, +U 0.32 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.32 SHGC 0.4 Simple Glazing,,,,, +U 0.7 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.7 SHGC 0.45 Simple Glazing,,,,, +U 0.59 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.59 SHGC 0.45 Simple Glazing,,,,, +U 0.44 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.44 SHGC 0.45 Simple Glazing,,,,, +U 0.93 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.93 SHGC 0.25 Simple Glazing,,,,, +U 0.75 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 0.75 SHGC 0.45 Simple Glazing,,,,, +U 0.3 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.3 SHGC 0.4 Simple Glazing,,,,, +U 0.36 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.36 SHGC 0.4 Simple Glazing,,,,, +U 0.9 SHGC 0.55 Simple Glazing Skylight,Skylight,,,,U 0.9 SHGC 0.55 Simple Glazing,,,,, +U 0.48 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.48 SHGC 0.45 Simple Glazing,,,,, diff --git a/data/openstudio_standards_data/initial_data/support_electric_equipment_space_type_name_tags.csv b/data/openstudio_standards_data/initial_data/support_electric_equipment_space_type_name_tags.csv new file mode 100644 index 0000000000..6cc1ce0e8f --- /dev/null +++ b/data/openstudio_standards_data/initial_data/support_electric_equipment_space_type_name_tags.csv @@ -0,0 +1,155 @@ +support_electric_equipment_space_type_name_tags +corridor - all other +dining - all other +electrical/mechanical +kitchen +laboratory +lobby - all other +locker room +lounge/breakroom - all other +office - enclosed <= 250 sf +office - enclosed > 250 sf +office - open +restroom - all other +stairwell +storage < 50 sf - all other +storage 50 to 1000 sf - all other +vehicular maintenance +atrium - first three floors +audience seating - convention center +classroom/lecture/training - all other +conference/meeting/multipurpose +exhibit - convention center +gymnasium exercise area +gymnasium playing area +laundry/washing +lobby - elevator +nurses station +post office - sorting area +"sports arena playing area, class IV" +audience seating - all other +confinement cells +judges chambers +library - stacks +storage - inactive +dining - bar/lounge/leisure +dining - cafeteria/fast food +dining - family +computer room +dormitory - living quarters +audience seating - exercise center +exam/treatment +library - reading +emergency vehicle garage +firestation - sleeping quarters +"parking area, interior" +audience seating - gymnasium +emergency room +patient room +corridor - hospital +fellowship hall - religious facility +lounge/breakroom - healthcare facility +operating room +physical therapy +storage < 50 sf - hospital +storage 50 to 1000 sf - hospital +guest room +lobby - hotel +library - cataloging +museum exhibit area +corridor - manufacturing facility +manufacturing equipment room +manufacturing low bay +performing arts dressing room +audience seating - auditorium +audience seating - motion picture theater +lobby - motion picture theater +Dwelling Unit +museum restoration +banking activity +warehouse - fine storage +classroom/lecture/training - penitentiary +dining - penitentiary +audience seating - performing arts theater +lobby - performing arts theater +audience seating - religious facility +worship/pulpit/choir area +classroom/lecture/training - preschool to 12th +"sports arena playing area, class II" +audience seating - sports arena +airport concourse +atrium < 20 ft height +atrium > 40 ft height +atrium >= 20 ft and <= 40 ft in height +baggage/carousel +"seating area, general" +transportation ticket counter +warehouse - bulk storage +workshop +gymnasium_playing_area +gymnasium_exercise_area +courtroom +confinement_cells +judges_chambers +emergency_vehicle_garage +firestation_sleeping_quarters +post_office_sorting_area +exhibit_convention_center +library_cataloging +library_stacks +library_reading +emergency_room +recovery +nurses_station +exam_treatment +pharmacy +patient_room +operating_room +nursery +medical_supply +physical_therapy +imaging +laundry_washing +automotive +manufacturing_low_bay +manufacturing_high_bay +detailed_manufacuring +manufacturing_equipment_room +manufacturing_control +manufacturing_extra_high_bay +guest_room +dormitory_living_quarters +museum_exhibit_area +museum_restoration +banking_activity +worship_pulpit_choir_area +fellowship_hall_religious_facility +sales +retail_mall_concourse +retail_dressing_room +sports_arena_ring_sports_area +sports_arena_court_sports_area +sports_arena_indoor_playing_field +sports_arena_playing_area_class_I +sports_arena_playing_area_class_II +sports_arena_playing_area_class_III +sports_arena_playing_area_class_IV +warehouse_fine_storage +warehouse_bulk_storage +parking_area_interior +airport_concourse +baggage_carousel +transportation_ticket_counter +sales_display_type_1 +sales_display_type_2 +sales_display_type_3 +sales_display_type_4 +breakroom +copy_print +computer_room +loading_dock +locker_room +seating_area_general +vehicular_maintenance +chapel_visually_impaired +recreation_common_living_visually_impaired diff --git a/data/openstudio_standards_data/initial_data/support_lighting_space_type_name_tags.csv b/data/openstudio_standards_data/initial_data/support_lighting_space_type_name_tags.csv new file mode 100644 index 0000000000..aa285798d8 --- /dev/null +++ b/data/openstudio_standards_data/initial_data/support_lighting_space_type_name_tags.csv @@ -0,0 +1,159 @@ +lighting_space_type_name +bam_automotive_facility +bam_convention_center +bam_courthouse +bam_dinin_bar_lounge_leisure +bam_dining_cafeteria_fast_food +bam_dining_family +bam_dormitory +bam_exercise_center +bam_fire_station +bam_gymnasium +bam_healthcare_clinic +bam_hospital +bam_hotel +bam_library +bam_manufacturing_facility +bam_motel +bam_motion_picture_theater +bam_multifamily +bam_museum +bam_office +bam_parking_garage +bam_penitentiary +bam_performing_arts_theater +bam_police_station +bam_post_office +bam_religious_facility +bam_retail +bam_school_university +bam_sports_arena +bam_town_hall +bam_transportation +bam_warehouse +bam_workshop +office_enclosed_small +office_enclosed_large +office_open +conference_meeting_multipurpose +classroom_lecture_training_general +classroom_lecture_training_penitentiary +lobby_general +lobby_hotel +lobby_performing_arts_theater +lobby_motion_picture_theater +lobby_visually_impaired +lobby_elevator +audience_seating_general +audience_seating_gymnasium +audience_seating_exercise_center +audience_seating_convention_center +audience_seating_penitentiary +audience_seating_religious_facility +audience_seating_sports_arena +audience_seating_performing_arts_theater +audience_seating_motion_picture_theater +audience_seating_transportation +audience_seating_auditorium +atrium_first_three_floor +atrium_each_additional_floor +atrium_low +atrium_medium +atrium_high +lounge_breakroom_general +lounge_breakroom_healthcare_facility +dining_general +dining_penitentiary +dining_hotel +dining_motel +dining_bar_lounge_leisure +dining_family +dining_cafeteria_fast_food +dining_visually_impaired +kitchen +laboratory_classroom +laboratory_all_other +restroom_visually_impaired +restroom_all_other +performing_arts_dressing_room +corridor_general +corridor_hospital +corridor_manufacturing_facility +corridor_visually_impaired +stairway +stairwell +storage_ all_other_small +storage_ all_other_large +storage_hospital_small +storage_hospital_large +storage_inactive +storage_inactive_museum +electrical_mechanical +workshop +gymnasium_playing_area +gymnasium_exercise_area +courtroom +confinement_cells +judges_chambers +emergency_vehicle_garage +firestation_sleeping_quarters +post_office_sorting_area +exhibit_convention_center +library_cataloging +library_stacks +library_reading +emergency_room +recovery +nurses_station +exam_treatment +pharmacy +patient_room +operating_room +nursery +medical_supply +physical_therapy +imaging +laundry_washing +automotive +manufacturing_low_bay +manufacturing_high_bay +detailed_manufacuring +manufacturing_equipment_room +manufacturing_control +manufacturing_extra_high_bay +guest_room +dormitory_living_quarters +museum_exhibit_area +museum_restoration +banking_activity +worship_pulpit_choir_area +fellowship_hall_religious_facility +sales +retail_mall_concourse +retail_dressing_room +sports_arena_ring_sports_area +sports_arena_court_sports_area +sports_arena_indoor_playing_field +sports_arena_playing_area_class_I +sports_arena_playing_area_class_II +sports_arena_playing_area_class_III +sports_arena_playing_area_class_IV +warehouse_fine_storage +warehouse_bulk_storage +parking_area_interior +airport_concourse +baggage_carousel +transportation_ticket_counter +sales_display_type_1 +sales_display_type_2 +sales_display_type_3 +sales_display_type_4 +breakroom +copy_print +computer_room +loading_dock +locker_room +seating_area_general +vehicular_maintenance +chapel_visually_impaired +recreation_common_living_visually_impaired diff --git a/data/openstudio_standards_data/initial_data/support_materials.csv b/data/openstudio_standards_data/initial_data/support_materials.csv new file mode 100644 index 0000000000..2cf92ec668 --- /dev/null +++ b/data/openstudio_standards_data/initial_data/support_materials.csv @@ -0,0 +1,1390 @@ +name,material_type,roughness,thickness,conductivity,resistance,density,specific_heat,thermal_absorptance,solar_absorptance,visible_absorptance,gas_type,u_factor,solar_heat_gain_coefficient,visible_transmittance,optical_data_type,solar_transmittance_at_normal_incidence,front_side_solar_reflectance_at_normal_incidence,back_side_solar_reflectance_at_normal_incidence,visible_transmittance_at_normal_incidence,front_side_visible_reflectance_at_normal_incidence,back_side_visible_reflectance_at_normal_incidence,infrared_transmittance_at_normal_incidence,front_side_infrared_hemispherical_emissivity,back_side_infrared_hemispherical_emissivity,dirt_correction_factor_for_solar_and_visible_transmittance,solar_diffusing,frame_width,annotation +1 Coat Stucco,StandardOpaqueMaterial,MediumRough,0.38,5.0004,0.07599392,115.81,0.2,,,,,,,,,,,,,,,,,,,,, +1/2 in. Gypsum Board,StandardOpaqueMaterial,Smooth,0.5,1.109355488,0.450712153,49.94236846,0.260342027,0.9,0.7,0.5,,,,,,,,,,,,,,,,,, +1/2IN Gypsum,StandardOpaqueMaterial,Smooth,0.5,1.109355488,0.450712153,48.99970626,0.198242094,0.9,0.4,0.4,,,,,,,,,,,,,,,,,, +10 PSF Roof - 1 in.,StandardOpaqueMaterial,VeryRough,1,12.0048,0.083300013,120,0.2,,,,,,,,,,,,,,,,,,,,, +100mm Normalweight concrete floor,StandardOpaqueMaterial,MediumRough,4,16.0194175,0.249696969,144.957816,0.198852772,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +12 in. Normalweight Concrete Floor,StandardOpaqueMaterial,MediumRough,12,16.01631985,0.749235786,144.9577245,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +15 PSF Roof - 1 1/2 in.,StandardOpaqueMaterial,VeryRough,1.5,18.0072,0.083300013,120,0.2,,,,,,,,,,,,,,,,,,,,, +1IN Stucco,StandardOpaqueMaterial,Smooth,0.996062992,4.79657579,0.207661264,115.9911508,0.199914015,0.9,0.7,0.92,,,,,,,,,,,,,,,,,, +25 PSF Roof - 2 1/2 in.,StandardOpaqueMaterial,VeryRough,2.5,30.012,0.083300013,120,0.2,,,,,,,,,,,,,,,,,,,,, +25mm Stucco,StandardOpaqueMaterial,Smooth,1,4.992099695,0.200316512,115.8662948,0.200630553,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +3 Coat Stucco,StandardOpaqueMaterial,MediumRough,0.88,4.3752,0.201133662,116,0.2,,,,,,,,,,,,,,,,,,,,, +4 in. Normalweight Concrete Floor,StandardOpaqueMaterial,MediumRough,4,16.01631985,0.249745262,144.9577245,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +4 in. Normalweight Concrete Wall,StandardOpaqueMaterial,MediumRough,4,16.01631985,0.249745262,144.9577245,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +5 PSF Roof - 1/2 in.,StandardOpaqueMaterial,VeryRough,0.5,6.0024,0.083300013,120,0.2,,,,,,,,,,,,,,,,,,,,, +5/8 in. Gypsum Board,StandardOpaqueMaterial,MediumSmooth,0.625984252,1.109355488,0.56427742,49.94236846,0.260342027,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +5/8 in. Plywood,StandardOpaqueMaterial,Smooth,0.625984252,0.832016616,0.752369893,33.96081055,0.289003535,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +6 in. Heavyweight Concrete Roof,StandardOpaqueMaterial,MediumRough,6,16.01631985,0.374617893,144.9577245,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +6 in. Normalweight Concrete Floor,StandardOpaqueMaterial,MediumRough,6,16.01631985,0.374617893,144.9577245,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +8 in. Concrete Block Basement Wall,StandardOpaqueMaterial,MediumRough,8,9.193783605,0.870153176,114.9923034,0.217827458,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +8 in. Concrete Block Wall,StandardOpaqueMaterial,MediumRough,8,4.992099695,1.602532098,49.94236846,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +8 in. Normalweight Concrete Floor,StandardOpaqueMaterial,MediumRough,8,16.01631985,0.499490524,144.9577245,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +8 in. Normalweight Concrete Wall,StandardOpaqueMaterial,MediumRough,8,16.01631985,0.499490524,144.9577245,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +8IN Concrete HW,StandardOpaqueMaterial,MediumRough,8.003937008,11.99213282,0.667432318,140.0259156,0.199914015,0.9,0.65,0.65,,,,,,,,,,,,,,,,,, +8IN CONCRETE HW RefBldg,StandardOpaqueMaterial,Rough,8,9.089781528,0.880109162,139.8386317,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Acoustic Ceiling,StandardOpaqueMaterial,MediumSmooth,0.5,0.395207893,1.26515692,17.97925265,0.319814656,0.9,0.7,0.2,,,,,,,,,,,,,,,,,, +Acoustic Tile - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,0.3996,1.251251251,18,0.19,,,,,,,,,,,,,,,,,,,,, +Acoustic Tile - 3/4 in.,StandardOpaqueMaterial,MediumSmooth,0.75,0.3996,1.876876877,18,0.19,,,,,,,,,,,,,,,,,,,,, +Acoustic Tile - 3/8 in.,StandardOpaqueMaterial,MediumSmooth,0.38,0.39,0.974358974,18,0.19,,,,,,,,,,,,,,,,,,,,, +Adiabatic Material,MasslessOpaqueMaterial,,,,9999,,,,,,,,,,,,,,,,,,,,,,, +Aggregate - 45 lb/ft3 - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,1.56,0.320512821,45,0.32,,,,,,,,,,,,,,,,,,,,, +Aggregate - 45 lb/ft3 - 5/8 in.,StandardOpaqueMaterial,MediumSmooth,0.63,1.5996,0.393848462,45,0.32,,,,,,,,,,,,,,,,,,,,, +Aggregate - 45 lb/ft3 - on metal lath - 3/4 in.,StandardOpaqueMaterial,MediumSmooth,0.75,1.5996,0.468867217,45,0.32,,,,,,,,,,,,,,,,,,,,, +Aggregate - Perlite - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,1.2996,0.384733764,45,0.32,,,,,,,,,,,,,,,,,,,,, +Aggregate - Perlite - 5/8 in.,StandardOpaqueMaterial,Smooth,0.63,1.5,0.42,45,0.32,,,,,,,,,,,,,,,,,,,,, +Aggregate - Perlite - on metal lath - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,1.7004,0.441072689,45,0.32,,,,,,,,,,,,,,,,,,,,, +Air - Cavity - Wall Roof Ceiling - 4 in. or more,StandardOpaqueMaterial,Smooth,6,6.5196,0.920301859,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Ceiling - 1 1/2 in.,StandardOpaqueMaterial,Smooth,1.5,1.95,0.769230769,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Ceiling - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.6804,0.734861846,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Ceiling - 3 1/2 in.,StandardOpaqueMaterial,Smooth,3.5,4.38,0.799086758,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Ceiling - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,0.9996,0.75030012,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Floor - 1 1/2 in.,StandardOpaqueMaterial,Smooth,1.5,1.5996,0.937734434,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Floor - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.6504,0.768757688,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Floor - 3 1/2 in.,StandardOpaqueMaterial,Smooth,3.5,3.5004,0.999885727,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Floor - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,0.8796,0.8526603,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Metal Wall Framing - 16 or 24 in. OC,StandardOpaqueMaterial,Smooth,5.5,8.46,0.650118203,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Roof - 1 1/2 in.,StandardOpaqueMaterial,Smooth,1.5,1.8804,0.797702616,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Roof - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.66,0.757575758,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Roof - 3 1/2 in.,StandardOpaqueMaterial,Smooth,3.5,4.2696,0.819748923,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Roof - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,0.93,0.806451613,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Wall - 1 1/2 in.,StandardOpaqueMaterial,Smooth,1.5,1.7196,0.872295883,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Wall - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.6504,0.768757688,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Wall - 3 1/2 in.,StandardOpaqueMaterial,Smooth,3.5,4.1196,0.849597048,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Wall - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,0.8904,0.842318059,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +AIR 13MM,Gas,,0.5,,,,,,,,Air,,,,,,,,,,,,,,,,, +AIR 3MM,Gas,,0.125984252,,,,,,,,Air,,,,,,,,,,,,,,,,, +AIR 6MM,Gas,,0.248031496,,,,,,,,Air,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Double glass with no low e - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.9,2.522222222,29.09,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Double glass with no low e - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.8196,3.989751098,20.44,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Double glass with no low e - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,1.08,4.138888889,15.23,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Double glass with no low e - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,1.3296,4.264440433,12.22,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Double glass with no low e - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,1.5996,4.294823706,10.26,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Double glass with no low e - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.8504,4.361219196,8.88,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Double glass with no low e - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.5304,3.450226244,35.69,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Double glass with no low e - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.6696,3.808243728,25.92,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - No Ins.,StandardOpaqueMaterial,Smooth,2.27,1.1796,1.924381146,29.09,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.8496,3.848870056,20.44,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,1.1004,4.062159215,15.23,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,1.35,4.2,12.22,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,1.6104,4.266020864,10.26,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.86,4.338709677,8.88,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.5604,3.265524625,35.69,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.6996,3.644939966,25.92,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Triple or low e glass - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.78,2.91025641,29.09,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Triple or low e glass - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.8196,3.989751098,20.44,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Triple or low e glass - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,1.08,4.138888889,15.23,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Triple or low e glass - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,1.3296,4.264440433,12.22,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Triple or low e glass - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,1.5996,4.294823706,10.26,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Triple or low e glass - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.8504,4.361219196,8.88,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Triple or low e glass - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.51,3.588235294,35.69,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Triple or low e glass - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.6696,3.808243728,25.92,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Double glass with no low e coatings - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.8304,2.733622351,29.09,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Double glass with no low e coatings - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.6504,5.027675277,20.44,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Double glass with no low e coatings - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.8304,5.382947977,15.23,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Double glass with no low e coatings - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,1.00464,5.643812709,12.22,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Double glass with no low e coatings - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,1.1904,5.771169355,10.26,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Double glass with no low e coatings - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.3704,5.888791594,8.88,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Double glass with no low e coatings - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.4404,4.155313351,35.69,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Double glass with no low e coatings - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.54,4.722222222,25.92,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - No Ins.,StandardOpaqueMaterial,Smooth,2.27,1.1304,2.008138712,29.09,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.66,4.954545455,20.44,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.84,5.321428571,15.23,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,1.0104,5.611638955,12.22,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,1.1904,5.771169355,10.26,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.38,5.847826087,8.88,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.4704,3.890306122,35.69,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.5604,4.550321199,25.92,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Triple or low e glass - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.69,3.289855072,29.09,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Triple or low e glass - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.63648,5.137631976,20.44,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Triple or low e glass - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.8196,5.453879941,15.23,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Triple or low e glass - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,0.9996,5.672268908,12.22,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Triple or low e glass - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,1.1796,5.824008138,10.26,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Triple or low e glass - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.3704,5.888791594,8.88,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Triple or low e glass - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.41724,4.385964912,35.69,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Triple or low e glass - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.5304,4.807692308,25.92,0.26,,,,,,,,,,,,,,,,,,,,, +ARGON 13MM,Gas,,0.5,,,,,,,,Argon,,,,,,,,,,,,,,,,, +Asbestos or cement shingles - 3/8 in.,StandardOpaqueMaterial,VeryRough,0.38,1.7904,0.212243074,120,0.24,,,,,,,,,,,,,,,,,,,,, +Ash - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,1.1004,0.908760451,40.06,0.39,,,,,,,,,,,,,,,,,,,,, +Asphalt - bitumen with inert fill - 100 lb/ft3 - 3/4 in.,StandardOpaqueMaterial,VeryRough,0.75,3,0.25,100,0.3,,,,,,,,,,,,,,,,,,,,, +Asphalt - bitumen with inert fill - 144 lb/ft3 - 3/4 in.,StandardOpaqueMaterial,VeryRough,0.75,8.0004,0.093745313,144,0.3,,,,,,,,,,,,,,,,,,,,, +Asphalt roll roofing - 1/4 in.,StandardOpaqueMaterial,VeryRough,0.25,1.6704,0.149664751,70,0.36,,,,,,,,,,,,,,,,,,,,, +Asphalt Shingles,StandardOpaqueMaterial,VeryRough,0.125984252,0.277338872,0.454261067,69.91931585,0.30094583,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Asphalt shingles - 1/4 in.,StandardOpaqueMaterial,VeryRough,0.25,0.5604,0.446109921,69.89,0.3,,,,,,,,,,,,,,,,,,,,, +AtticFloor Insulation,StandardOpaqueMaterial,MediumRough,9.366141732,0.339740118,27.56854794,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Birch - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,1.1904,0.840053763,43.93,0.39,,,,,,,,,,,,,,,,,,,,, +BLUE 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.48,0.05,0.05,0.57,0.06,0.06,0,0.84,0.84,1,FALSE,, +Brick - 48 lb/ft3 - 3 5/8 in.,StandardOpaqueMaterial,Rough,3.63,1.5,2.42,48,0.19,,,,,,,,,,,,,,,,,,,,, +Brick - fired clay - 140 lb/ft3 - 3 5/8 in.,StandardOpaqueMaterial,MediumRough,3.63,8.22,0.441605839,139.78,0.19,,,,,,,,,,,,,,,,,,,,, +BRONZE 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.482,0.054,0.054,0.534,0.057,0.057,0,0.84,0.84,1,FALSE,, +Building Paper - 1/16 in.,StandardOpaqueMaterial,MediumSmooth,0.06,2.0004,0.029994001,70,0.3,,,,,,,,,,,,,,,,,,,,, +Built-up Roofing,StandardOpaqueMaterial,Rough,0.374015748,1.109355488,0.337146886,69.91931585,0.348715009,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Built-up roofing - 3/8 in.,StandardOpaqueMaterial,VeryRough,0.38,1.14,0.333333333,70,0.35,,,,,,,,,,,,,,,,,,,,, +Built-up Roofing - Highly Reflective,StandardOpaqueMaterial,Rough,0.374015748,1.109355488,0.337146886,69.91931585,0.348715009,0.75,0.45,0.7,,,,,,,,,,,,,,,,,, +Bulk Storage Products Material,StandardOpaqueMaterial,Rough,96.0001946,9.998066642,9.601875846,12.49999184,0.199866248,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +California Redwood - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,0.78,1.282051282,26.21,0.39,,,,,,,,,,,,,,,,,,,,, +Carpet - 3/4 in.,StandardOpaqueMaterial,Rough,0.75,0.3156,2.376425856,18,0.33,,,,,,,,,,,,,,,,,,,,, +Carpet - 3/4 in. CBES,StandardOpaqueMaterial,Smooth,0.75,0.34691,,18,0.33,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +ceiling_2_Insulation,StandardOpaqueMaterial,Smooth,3.96766,0.15963,,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 1 1/2 in. R8.8,StandardOpaqueMaterial,Rough,1.5,0.1704,8.802816901,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 1 in. R5.9,StandardOpaqueMaterial,Rough,1,0.1704,5.868544601,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 1/2 in. R2.9,StandardOpaqueMaterial,Rough,0.5,0.1704,2.9342723,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 1/4 in. R1.5,StandardOpaqueMaterial,Rough,0.25,0.1704,1.46713615,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 1/8 in. R0.7,StandardOpaqueMaterial,Rough,0.13,0.1704,0.762910798,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 2 1/2 in. R15,StandardOpaqueMaterial,Rough,2.5,0.1704,14.6713615,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 2 in. R12,StandardOpaqueMaterial,Rough,2,0.1704,11.7370892,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 3 1/2 in. R21,StandardOpaqueMaterial,Rough,3.5,0.1704,20.5399061,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 3 in. R18,StandardOpaqueMaterial,Rough,3,0.1704,17.6056338,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 4 1/2 in. R26,StandardOpaqueMaterial,Rough,4.5,0.1704,26.4084507,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 4 in. R23,StandardOpaqueMaterial,Rough,4,0.1704,23.4741784,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 5 1/2 in. R32,StandardOpaqueMaterial,Rough,5.5,0.1704,32.27699531,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 5 in. R29,StandardOpaqueMaterial,Rough,5,0.1704,29.342723,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 6 1/2 in. R38,StandardOpaqueMaterial,Rough,6.5,0.1704,38.14553991,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 6 in. R35,StandardOpaqueMaterial,Rough,6,0.1704,35.21126761,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Clay - Part Grouted and Empty - 130 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.12,1.923076923,130,0.13,,,,,,,,,,,,,,,,,,,,, +Clay - Part Grouted and Empty - 130 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,3.7596,2.127885945,130,0.13,,,,,,,,,,,,,,,,,,,,, +Clay - Part Grouted and Insulated - 130 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,2.7,2.222222222,130,0.13,,,,,,,,,,,,,,,,,,,,, +Clay - Part Grouted and Insulated - 130 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,3.12,2.564102564,130,0.13,,,,,,,,,,,,,,,,,,,,, +Clay - Solid Grout - 130 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.9,1.538461538,130,0.17,,,,,,,,,,,,,,,,,,,,, +Clay - Solid Grout - 130 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,4.56,1.754385965,130,0.17,,,,,,,,,,,,,,,,,,,,, +Clay tile - 1/2 in.,StandardOpaqueMaterial,MediumRough,0.5,0.1896,2.637130802,85,0.21,,,,,,,,,,,,,,,,,,,,, +Clay tile - hollow - 1 cell deep - 3 in.,StandardOpaqueMaterial,MediumRough,3,3.75,0.8,85,0.21,,,,,,,,,,,,,,,,,,,,, +Clay tile - hollow - 1 cell deep - 4 in.,StandardOpaqueMaterial,MediumRough,4,3.6,1.111111111,85,0.21,,,,,,,,,,,,,,,,,,,,, +Clay tile - hollow - 2 cells deep - 10 in.,StandardOpaqueMaterial,MediumRough,10,4.5,2.222222222,85,0.21,,,,,,,,,,,,,,,,,,,,, +Clay tile - hollow - 2 cells deep - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.9504,1.518833536,85,0.21,,,,,,,,,,,,,,,,,,,,, +Clay tile - hollow - 2 cells deep - 8 in.,StandardOpaqueMaterial,MediumRough,8,4.32,1.851851852,85,0.21,,,,,,,,,,,,,,,,,,,,, +Clay tile - hollow - 3 cells deep - 12 in.,StandardOpaqueMaterial,MediumRough,12,4.8,2.5,85,0.21,,,,,,,,,,,,,,,,,,,,, +Clay Tile - Paver,StandardOpaqueMaterial,MediumRough,0.38,12.504,0.030390275,139.78,0.22,,,,,,,,,,,,,,,,,,,,, +CLEAR 2.5MM,StandardGlazing,,0.098425197,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.8,0.075,0.075,0.901,0.081,0.081,0,0.84,0.84,1,FALSE,, +CLEAR 3MM,StandardGlazing,,0.118110236,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.837,0.075,0.075,0.898,0.081,0.081,0,0.84,0.84,1,FALSE,, +CLEAR 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.775,0.071,0.071,0.881,0.08,0.08,0,0.84,0.84,1,FALSE,, +COATED POLY-55,StandardGlazing,,0.02007874,0.970686052,1.030199206,,,,,,,,,,SpectralAverage,0.32,0.582,0.593,0.551,0.336,0.375,0,0.046,0.72,1,FALSE,, +COATED POLY-77,StandardGlazing,,0.02007874,0.970686052,1.030199206,,,,,,,,,,SpectralAverage,0.504,0.402,0.398,0.766,0.147,0.167,0,0.075,0.72,1,FALSE,, +Compliance Insulation R0.01,StandardOpaqueMaterial,MediumSmooth,0.0016,0.1596,0.010025063,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R0.02,StandardOpaqueMaterial,MediumSmooth,0.0032,0.1596,0.020050125,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R0.10,StandardOpaqueMaterial,MediumSmooth,0.016,0.1596,0.100250627,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R1.35,StandardOpaqueMaterial,MediumSmooth,0.216,0.1596,1.353383459,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R1.41,StandardOpaqueMaterial,MediumSmooth,0.2256,0.1596,1.413533835,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R1.54,StandardOpaqueMaterial,MediumSmooth,0.2464,0.1596,1.543859649,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R10.06,StandardOpaqueMaterial,MediumSmooth,1.6096,0.1596,10.08521303,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R12.55,StandardOpaqueMaterial,MediumSmooth,2.008,0.1596,12.58145363,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R12.69,StandardOpaqueMaterial,MediumSmooth,2.0304,0.1596,12.72180451,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R13.99,StandardOpaqueMaterial,MediumSmooth,2.2384,0.1596,14.02506266,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R14.14,StandardOpaqueMaterial,MediumSmooth,2.2624,0.1596,14.1754386,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R14.32,StandardOpaqueMaterial,MediumSmooth,2.2912,0.1596,14.35588972,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R14.60,StandardOpaqueMaterial,MediumSmooth,2.336,0.1596,14.63659148,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R15.54,StandardOpaqueMaterial,MediumSmooth,2.4864,0.1596,15.57894737,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R16.58,StandardOpaqueMaterial,MediumSmooth,2.6528,0.1596,16.62155388,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R16.69,StandardOpaqueMaterial,MediumSmooth,2.6704,0.1596,16.73182957,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R17.67,StandardOpaqueMaterial,MediumSmooth,2.8272,0.1596,17.71428571,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R19.63,StandardOpaqueMaterial,MediumSmooth,3.1408,0.1596,19.67919799,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R2.15,StandardOpaqueMaterial,MediumSmooth,0.344,0.1596,2.155388471,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R2.19,StandardOpaqueMaterial,MediumSmooth,0.3504,0.1596,2.195488722,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R2.85,StandardOpaqueMaterial,MediumSmooth,0.456,0.1596,2.857142857,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R2.89,StandardOpaqueMaterial,MediumSmooth,0.4624,0.1596,2.897243108,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R20.05,StandardOpaqueMaterial,MediumSmooth,3.208,0.1596,20.10025063,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R21.18,StandardOpaqueMaterial,MediumSmooth,3.3888,0.1596,21.23308271,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R21.39,StandardOpaqueMaterial,MediumSmooth,3.4224,0.1596,21.44360902,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R22.48,StandardOpaqueMaterial,MediumSmooth,3.5968,0.1596,22.53634085,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R24.86,StandardOpaqueMaterial,MediumSmooth,3.9776,0.1596,24.92230576,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R25.16,StandardOpaqueMaterial,MediumSmooth,4.0256,0.1596,25.22305764,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R28.63,StandardOpaqueMaterial,MediumSmooth,4.5808,0.1596,28.70175439,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R3.63,StandardOpaqueMaterial,MediumSmooth,0.5808,0.1596,3.639097744,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R3.70,StandardOpaqueMaterial,MediumSmooth,0.592,0.1596,3.709273183,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R34.93,StandardOpaqueMaterial,MediumSmooth,5.5888,0.1596,35.01754386,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R6.32,StandardOpaqueMaterial,MediumSmooth,1.0112,0.1596,6.335839599,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R6.46,StandardOpaqueMaterial,MediumSmooth,1.0336,0.1596,6.476190476,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R7.10,StandardOpaqueMaterial,MediumSmooth,1.136,0.1596,7.117794486,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R7.18,StandardOpaqueMaterial,MediumSmooth,1.1488,0.1596,7.197994987,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R7.39,StandardOpaqueMaterial,MediumSmooth,1.1824,0.1596,7.408521303,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R8.00,StandardOpaqueMaterial,MediumSmooth,1.28,0.1596,8.020050125,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R8.07,StandardOpaqueMaterial,MediumSmooth,1.2912,0.1596,8.090225564,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R9.83,StandardOpaqueMaterial,MediumSmooth,1.5697,0.1596,9.835213033,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R9.94,StandardOpaqueMaterial,MediumSmooth,1.5904,0.1596,9.964912281,1,0.27,,,,,,,,,,,,,,,,,,,,, +Concrete - 100 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,6.2496,1.600102407,100,0.21,,,,,,,,,,,,,,,,,,,,, +Concrete - 100 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,6.2496,1.920122888,100,0.21,,,,,,,,,,,,,,,,,,,,, +Concrete - 100 lb/ft3 - 2 in.,StandardOpaqueMaterial,MediumRough,2,6.2496,0.320020481,100,0.21,,,,,,,,,,,,,,,,,,,,, +Concrete - 100 lb/ft3 - 4 in.,StandardOpaqueMaterial,MediumRough,4,6.2496,0.640040963,100,0.21,,,,,,,,,,,,,,,,,,,,, +Concrete - 100 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,6.2496,0.960061444,100,0.21,,,,,,,,,,,,,,,,,,,,, +Concrete - 100 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,6.2496,1.280081925,100,0.21,,,,,,,,,,,,,,,,,,,,, +Concrete - 140 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,13.53,0.7390983,139.78,0.22,,,,,,,,,,,,,,,,,,,,, +Concrete - 140 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,13.53,0.88691796,139.78,0.22,,,,,,,,,,,,,,,,,,,,, +Concrete - 140 lb/ft3 - 2 in.,StandardOpaqueMaterial,MediumRough,2,13.53,0.14781966,139.78,0.22,,,,,,,,,,,,,,,,,,,,, +Concrete - 140 lb/ft3 - 4 in.,StandardOpaqueMaterial,MediumRough,4,13.53,0.29563932,139.78,0.22,,,,,,,,,,,,,,,,,,,,, +Concrete - 140 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,13.53,0.44345898,139.78,0.22,,,,,,,,,,,,,,,,,,,,, +Concrete - 140 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,13.53,0.59127864,139.78,0.22,,,,,,,,,,,,,,,,,,,,, +Concrete - 80 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,3.6804,2.717095968,79.87,0.2,,,,,,,,,,,,,,,,,,,,, +Concrete - 80 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,3.6804,3.260515161,79.87,0.2,,,,,,,,,,,,,,,,,,,,, +Concrete - 80 lb/ft3 - 2 in.,StandardOpaqueMaterial,MediumRough,2,3.6804,0.543419194,79.87,0.2,,,,,,,,,,,,,,,,,,,,, +Concrete - 80 lb/ft3 - 4 in.,StandardOpaqueMaterial,MediumRough,4,3.6804,1.086838387,79.87,0.2,,,,,,,,,,,,,,,,,,,,, +Concrete - 80 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.6804,1.630257581,79.87,0.2,,,,,,,,,,,,,,,,,,,,, +Concrete - 80 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,3.6804,2.173676774,79.87,0.2,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Empty - 105 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,4.5996,2.174102096,105,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Empty - 105 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,5.16,2.325581395,105,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Empty - 105 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.24,1.851851852,105,0.15,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Empty - 105 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,3.9996,2.00020002,105,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Empty - 115 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,4.8996,2.040982937,115,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Empty - 115 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,5.52,2.173913043,115,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Empty - 115 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.48,1.724137931,115,0.15,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Empty - 115 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,4.2396,1.886970469,115,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Empty - 125 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,5.1996,1.923224863,125,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Empty - 125 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,5.88,2.040816327,125,0.13,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Empty - 125 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.66,1.639344262,125,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Empty - 125 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,4.4796,1.785873739,125,0.13,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Insulated - 105 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,3.3996,2.941522532,105,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Insulated - 105 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,3.6,3.333333333,105,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Insulated - 105 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,2.64,2.272727273,105,0.15,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Insulated - 105 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,2.9604,2.702337522,105,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Insulated - 115 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,3.6996,2.702994918,115,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Insulated - 115 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,3.96,3.03030303,115,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Insulated - 115 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,2.88,2.083333333,115,0.15,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Insulated - 115 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,3.2796,2.439321869,115,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Insulated - 125 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,4.1004,2.43878646,125,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Insulated - 125 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,4.32,2.777777778,125,0.13,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Insulated - 125 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.12,1.923076923,125,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Insulated - 125 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,3.5196,2.272985567,125,0.13,,,,,,,,,,,,,,,,,,,,, +Concrete - Solid Grout - 105 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,8.4744,1.180024545,105,0.22,,,,,,,,,,,,,,,,,,,,, +Concrete - Solid Grout - 105 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,8.5704,1.40016802,105,0.22,,,,,,,,,,,,,,,,,,,,, +Concrete - Solid Grout - 105 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,8.3328,0.720046083,105,0.21,,,,,,,,,,,,,,,,,,,,, +Concrete - Solid Grout - 105 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,8.3328,0.960061444,105,0.22,,,,,,,,,,,,,,,,,,,,, +Concrete - Solid Grout - 115 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,9.174,1.090037061,115,0.21,,,,,,,,,,,,,,,,,,,,, +Concrete - Solid Grout - 115 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,9.2304,1.300052002,115,0.21,,,,,,,,,,,,,,,,,,,,, +Concrete - Solid Grout - 115 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,10.17,0.589970501,115,0.2,,,,,,,,,,,,,,,,,,,,, +Concrete - Solid Grout - 115 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,9.1224,0.876962203,115,0.2,,,,,,,,,,,,,,,,,,,,, +Concrete - Solid Grout - 125 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,10.1016,0.989942187,125,0.2,,,,,,,,,,,,,,,,,,,,, +Concrete - Solid Grout - 125 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,10.0836,1.190051172,125,0.2,,,,,,,,,,,,,,,,,,,,, +Concrete - Solid Grout - 125 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,10.17,0.589970501,125,0.19,,,,,,,,,,,,,,,,,,,,, +Concrete - Solid Grout - 125 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,10.1268,0.789983015,125,0.2,,,,,,,,,,,,,,,,,,,,, +Concrete Paver,StandardOpaqueMaterial,MediumRough,0.38,4.5024,0.084399431,144,0.2,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 100% Ins. Layer - No Steel in Ins. - Ins. 1 1/2 in.,StandardOpaqueMaterial,MediumRough,13.5,1.8396,7.338551859,133.44,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 100% Ins. Layer - No Steel in Ins. - Ins. 2 in.,StandardOpaqueMaterial,MediumRough,14,1.4496,9.657836645,128.71,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 100% Ins. Layer - No Steel in Ins. - Ins. 3 in.,StandardOpaqueMaterial,MediumRough,15,1.05,14.28571429,120.2,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 100% Ins. Layer - No Steel in Ins. - Ins. 4 in.,StandardOpaqueMaterial,MediumRough,16,0.8496,18.83239171,112.75,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 100% Ins. Layer - No Steel in Ins. - Ins. 6 in.,StandardOpaqueMaterial,MediumRough,18,0.63,28.57142857,100.33,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 100% Ins. Layer - Steel in Ins. - Ins. 1 1/2 in.,StandardOpaqueMaterial,MediumRough,13.5,2.5704,5.25210084,133.44,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 100% Ins. Layer - Steel in Ins. - Ins. 2 in.,StandardOpaqueMaterial,MediumRough,14,2.01,6.965174129,128.71,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 100% Ins. Layer - Steel in Ins. - Ins. 3 in.,StandardOpaqueMaterial,MediumRough,15,1.4796,10.1378751,120.2,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 100% Ins. Layer - Steel in Ins. - Ins. 4 in.,StandardOpaqueMaterial,MediumRough,16,1.1904,13.44086022,112.75,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 100% Ins. Layer - Steel in Ins. - Ins. 6 in.,StandardOpaqueMaterial,MediumRough,18,0.9,20,100.33,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 80% Ins. Layer - No Steel in Ins. - Ins. 1 1/2 in.,StandardOpaqueMaterial,MediumRough,13.5,15.8604,0.851176515,133.44,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 80% Ins. Layer - No Steel in Ins. - Ins. 2 in.,StandardOpaqueMaterial,MediumRough,14,14.7504,0.949126803,128.71,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 80% Ins. Layer - No Steel in Ins. - Ins. 3 in.,StandardOpaqueMaterial,MediumRough,15,11.9904,1.251000801,120.2,0.12,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 80% Ins. Layer - No Steel in Ins. - Ins. 4 in.,StandardOpaqueMaterial,MediumRough,16,10.3404,1.547328923,112.75,0.12,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 80% Ins. Layer - No Steel in Ins. - Ins. 6 in.,StandardOpaqueMaterial,MediumRough,18,8.3604,2.153007033,100.33,0.13,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 80% Ins. Layer - Steel in Ins. - Ins. 1 1/2 in.,StandardOpaqueMaterial,MediumRough,13.5,15.8604,0.851176515,133.44,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 80% Ins. Layer - Steel in Ins. - Ins. 2 in.,StandardOpaqueMaterial,MediumRough,14,25.1796,0.556005655,128.71,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 80% Ins. Layer - Steel in Ins. - Ins. 3 in.,StandardOpaqueMaterial,MediumRough,15,31.5096,0.476045396,120.2,0.12,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 80% Ins. Layer - Steel in Ins. - Ins. 4 in.,StandardOpaqueMaterial,MediumRough,16,38.37,0.416992442,112.75,0.12,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 80% Ins. Layer - Steel in Ins. - Ins. 6 in.,StandardOpaqueMaterial,MediumRough,18,54.0504,0.333022512,100.33,0.13,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 90% Ins. Layer - No Steel in Ins. - Ins. 1 1/2 in.,StandardOpaqueMaterial,MediumRough,13.5,10.7904,1.2511121,133.44,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 90% Ins. Layer - No Steel in Ins. - Ins. 2 in.,StandardOpaqueMaterial,MediumRough,14,9.66,1.449275362,128.71,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 90% Ins. Layer - No Steel in Ins. - Ins. 3 in.,StandardOpaqueMaterial,MediumRough,15,7.32,2.049180328,120.2,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 90% Ins. Layer - No Steel in Ins. - Ins. 4 in.,StandardOpaqueMaterial,MediumRough,16,6.0396,2.649182065,112.75,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 90% Ins. Layer - No Steel in Ins. - Ins. 6 in.,StandardOpaqueMaterial,MediumRough,18,4.7904,3.75751503,100.33,0.12,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 90% Ins. Layer - Steel in Ins. - Ins. 1 1/2 in.,StandardOpaqueMaterial,MediumRough,13.5,11.7396,1.149954002,133.44,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 90% Ins. Layer - Steel in Ins. - Ins. 2 in.,StandardOpaqueMaterial,MediumRough,14,9.66,1.449275362,128.71,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 90% Ins. Layer - Steel in Ins. - Ins. 3 in.,StandardOpaqueMaterial,MediumRough,15,7.6896,1.950686642,120.2,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 90% Ins. Layer - Steel in Ins. - Ins. 4 in.,StandardOpaqueMaterial,MediumRough,16,6.5304,2.450079628,112.75,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 90% Ins. Layer - Steel in Ins. - Ins. 6 in.,StandardOpaqueMaterial,MediumRough,18,5.0604,3.557031065,100.33,0.12,,,,,,,,,,,,,,,,,,,,, +Concrete/Sand Aggregate - 6 in.,StandardOpaqueMaterial,Smooth,6.01,4.29,1.400932401,116,0.2,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Double glass with no low e coatings - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.9,2.522222222,29.09,0.26,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Double glass with no low e coatings - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.26196,12.4828218,20.44,0.26,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Double glass with no low e coatings - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.25296,17.67077799,15.23,0.27,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Double glass with no low e coatings - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,0.25308,22.40398293,12.22,0.27,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Double glass with no low e coatings - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,0.2478,27.72397094,10.26,0.27,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Double glass with no low e coatings - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,0.2484,32.48792271,8.88,0.27,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Double glass with no low e coatings - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.2814,6.503198294,35.69,0.26,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Double glass with no low e coatings - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.27,9.444444444,25.92,0.26,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Single glass pane. stone. or metal pane - No Ins.,StandardOpaqueMaterial,Smooth,2.27,1.1796,1.924381146,29.09,0.26,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Single glass pane. stone. or metal pane - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.27312,11.97275923,20.44,0.26,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Single glass pane. stone. or metal pane - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.2628,17.00913242,15.23,0.27,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Single glass pane. stone. or metal pane - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,0.2592,21.875,12.22,0.27,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Single glass pane. stone. or metal pane - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,0.25512,26.92850423,10.26,0.27,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Single glass pane. stone. or metal pane - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,0.25692,31.41055582,8.88,0.27,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Single glass pane. stone. or metal pane - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.3096,5.910852713,35.69,0.26,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Single glass pane. stone. or metal pane - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.28476,8.954909397,25.92,0.26,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Triple or low e glass - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.78,2.91025641,29.09,0.26,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Triple or low e glass - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.25452,12.84771334,20.44,0.26,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Triple or low e glass - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.24804,18.02128689,15.23,0.27,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Triple or low e glass - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,0.24696,22.95918367,12.22,0.27,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Triple or low e glass - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,0.2478,27.72397094,10.26,0.27,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Triple or low e glass - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,0.2484,32.48792271,8.88,0.27,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Triple or low e glass - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.2652,6.900452489,35.69,0.26,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Triple or low e glass - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.25752,9.902143523,25.92,0.26,,,,,,,,,,,,,,,,,,,,, +CP02 CARPET PAD,MasslessOpaqueMaterial,VeryRough,,,1.229230374,,,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +Douglas Fir-Larch - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,0.9804,1.01999184,34.88,0.39,,,,,,,,,,,,,,,,,,,,, +ECABS-2 BLEACHED 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.814,0.086,0.086,0.847,0.099,0.099,0,0.84,0.1,1,FALSE,, +ECABS-2 COLORED 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.111,0.179,0.179,0.128,0.081,0.081,0,0.84,0.1,1,FALSE,, +ECREF-1 COLORED 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.099,0.219,0.219,0.155,0.073,0.073,0,0.84,0.84,1,FALSE,, +ECREF-2 BLEACHED 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.694,0.168,0.168,0.818,0.11,0.11,0,0.84,0.1,1,FALSE,, +ECREF-2 COLORED 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.099,0.219,0.219,0.155,0.073,0.073,0,0.84,0.1,1,FALSE,, +Expanded perlite - organic bonded - 1 1/2 in. R4.2,StandardOpaqueMaterial,MediumSmooth,1.5,0.36,4.166666667,1,0.3,,,,,,,,,,,,,,,,,,,,, +Expanded perlite - organic bonded - 1 in. R2.8,StandardOpaqueMaterial,MediumSmooth,1,0.36,2.777777778,1,0.3,,,,,,,,,,,,,,,,,,,,, +Expanded perlite - organic bonded - 2 in. R5.6,StandardOpaqueMaterial,MediumSmooth,2,0.36,5.555555556,1,0.3,,,,,,,,,,,,,,,,,,,,, +Expanded perlite - organic bonded - 3 in. R8.3,StandardOpaqueMaterial,MediumSmooth,3,0.36,8.333333333,1,0.3,,,,,,,,,,,,,,,,,,,,, +Expanded perlite - organic bonded - 3/4 in. R2.1,StandardOpaqueMaterial,MediumSmooth,0.75,0.36,2.083333333,1,0.3,,,,,,,,,,,,,,,,,,,,, +Expanded perlite - organic bonded - 4 in. R11,StandardOpaqueMaterial,MediumSmooth,4,0.36,11.11111111,1,0.3,,,,,,,,,,,,,,,,,,,,, +Expanded perlite - organic bonded - 6 in. R17,StandardOpaqueMaterial,MediumSmooth,6,0.36,16.66666667,1,0.3,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 1 1/2 in. R6.3,StandardOpaqueMaterial,MediumSmooth,1.5,0.24,6.25,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 1 1/4 in. R5.2,StandardOpaqueMaterial,MediumSmooth,1.25,0.24,5.208333333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 1 15/16 in. R8.1,StandardOpaqueMaterial,MediumSmooth,1.94,0.24,8.083333333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 1 3/4 in. R7.3,StandardOpaqueMaterial,MediumSmooth,1.75,0.24,7.291666667,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 1 7/8 in. R8.0,StandardOpaqueMaterial,MediumSmooth,1.92,0.24,8,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 1 in. R4.2,StandardOpaqueMaterial,MediumSmooth,1,0.24,4.166666667,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 1/2 in. R2.1,StandardOpaqueMaterial,MediumSmooth,0.5,0.24,2.083333333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 1/4 in. R1.0,StandardOpaqueMaterial,MediumSmooth,0.25,0.24,1.041666667,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 2 2/5 in. R10,StandardOpaqueMaterial,MediumSmooth,2.4,0.24,10,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 2 7/16 in. R10,StandardOpaqueMaterial,MediumSmooth,2.43,0.24,10.125,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 2 in. R8.3,StandardOpaqueMaterial,MediumSmooth,2,0.24,8.333333333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 3 1/2 in. R15,StandardOpaqueMaterial,MediumSmooth,3.5,0.24,14.58333333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 3 1/3 in. R14,StandardOpaqueMaterial,MediumSmooth,3.35,0.24,13.95833333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 3 2/5 in. R14,StandardOpaqueMaterial,MediumSmooth,3.39,0.24,14.125,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 3 in. R13,StandardOpaqueMaterial,MediumSmooth,3.01,0.24,12.54166667,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 3/4 in. R3.1,StandardOpaqueMaterial,MediumSmooth,0.75,0.24,3.125,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 4 1/16 in. R17,StandardOpaqueMaterial,MediumSmooth,4.05,0.24,16.875,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 4 7/10 in. R20,StandardOpaqueMaterial,MediumSmooth,4.71,0.24,19.625,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 5 19/20 in. R25,StandardOpaqueMaterial,MediumSmooth,5.96,0.24,24.83333333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 5 2/5 in. R22,StandardOpaqueMaterial,MediumSmooth,5.2,0.24,21.66666667,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 6 1/10 in. R25,StandardOpaqueMaterial,MediumSmooth,6.11,0.24,25.45833333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 6 7/8 in. R29,StandardOpaqueMaterial,MediumSmooth,6.87,0.24,28.625,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 8 3/5 in. R35,StandardOpaqueMaterial,MediumSmooth,8.38,0.24,34.91666667,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polyurethane - 1 1/4 in. R7.8,StandardOpaqueMaterial,MediumSmooth,1.25,0.1596,7.832080201,1,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polyurethane - 1 in. R6.3,StandardOpaqueMaterial,MediumSmooth,1,0.1596,6.26566416,1,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polyurethane - 1/2 in. R3.1,StandardOpaqueMaterial,MediumSmooth,0.5,0.1596,3.13283208,1,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polyurethane - 2 in. R12.6,StandardOpaqueMaterial,MediumSmooth,2,0.1596,12.53132832,1,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polyurethane - 3/4 in. R4.7,StandardOpaqueMaterial,MediumSmooth,0.75,0.1596,4.69924812,1,0.27,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 1 1/2 in. R7.50,StandardOpaqueMaterial,MediumSmooth,1.5,0.200000004,7.49999985,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 1 1/4 in. R6.25,StandardOpaqueMaterial,MediumSmooth,1.25,0.200000004,6.249999875,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 1 3/4 in. R8.75,StandardOpaqueMaterial,MediumSmooth,1.75,0.200000004,8.749999825,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 1 7/8 in. R9.37,StandardOpaqueMaterial,MediumSmooth,1.88,0.200000004,9.399999812,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 1 in. R5.00,StandardOpaqueMaterial,MediumSmooth,1,0.200000004,4.9999999,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 1/2 in. R2.50,StandardOpaqueMaterial,MediumSmooth,0.5,0.200000004,2.49999995,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 1/4 in. R1.25,StandardOpaqueMaterial,MediumSmooth,0.25,0.200000004,1.249999975,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 2 1/2 in. R12.50,StandardOpaqueMaterial,MediumSmooth,2.5,0.200000004,12.49999975,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 2 in. R10.00,StandardOpaqueMaterial,MediumSmooth,2,0.200000004,9.9999998,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 3 1/2 in. R17.50,StandardOpaqueMaterial,MediumSmooth,3.5,0.200000004,17.49999965,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 3 in. R15.00,StandardOpaqueMaterial,MediumSmooth,3,0.200000004,14.9999997,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 3/4 in. R3.75,StandardOpaqueMaterial,MediumSmooth,0.75,0.200000004,3.749999925,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 4 1/2 in. R22.50,StandardOpaqueMaterial,MediumSmooth,4.5,0.200000004,22.49999955,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 4 in. R20.00,StandardOpaqueMaterial,MediumSmooth,4,0.200000004,19.9999996,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 5 1/2 in. R27.50,StandardOpaqueMaterial,MediumSmooth,5.5,0.200000004,27.49999945,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 5 in. R25.00,StandardOpaqueMaterial,MediumSmooth,5,0.200000004,24.9999995,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 6 1/2 in. R32.50,StandardOpaqueMaterial,MediumSmooth,6.5,0.200000004,32.49999935,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 6 in. R30.00,StandardOpaqueMaterial,MediumSmooth,6,0.200000004,29.9999994,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 8 1/2 in. R42.50,StandardOpaqueMaterial,MediumSmooth,8.5,0.200000004,42.49999915,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 8 in. R40.00,StandardOpaqueMaterial,MediumSmooth,8,0.200000004,39.9999992,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +F04 Wall air space resistance,AirGap,,,46.22314532,0.021634183,,,,,,,,,,,,,,,,,,,,,,, +F05 Ceiling air space resistance,AirGap,,,38.51928777,0.02596102,,,,,,,,,,,,,,,,,,,,,,, +F08 Metal surface,StandardOpaqueMaterial,Smooth,0.031496063,313.947603,0.000100323,488.4363635,0.119422948,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +F16 Acoustic tile,StandardOpaqueMaterial,MediumSmooth,0.751968504,0.416008308,1.807580497,22.97348949,0.140919079,0.9,0.3,0.3,,,,,,,,,,,,,,,,,, +Fiber cement board - 63 lb/ft3 - 1/3 in.,StandardOpaqueMaterial,Smooth,0.31,1.2996,0.238534934,63,0.2,,,,,,,,,,,,,,,,,,,,, +Fiber cement board - 88 lb/ft3 - 1/2 in.,StandardOpaqueMaterial,Smooth,0.47,1.7004,0.276405552,88,0.2,,,,,,,,,,,,,,,,,,,,, +Fiber cement board - 88 lb/ft3 - 1/3 in.,StandardOpaqueMaterial,Smooth,0.31,1.7004,0.182310045,88,0.2,,,,,,,,,,,,,,,,,,,,, +Fiberboard sheathing - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.4896,1.02124183,24.96,0.31,,,,,,,,,,,,,,,,,,,,, +Fixed Window 2.00/0.40/0.31,SimpleGlazing,,,,,,,,,,,0.35,0.4,0.31,,,,,,,,,,,,,, +Fixed Window 2.00/0.45/0.35,SimpleGlazing,,,,,,,,,,,0.35,0.45,0.35,,,,,,,,,,,,,, +Fixed Window 2.30/0.40/0.31,SimpleGlazing,,,,,,,,,,,0.4,0.4,0.31,,,,,,,,,,,,,, +Fixed Window 2.56/0.45/0.35,SimpleGlazing,,,,,,,,,,,0.45,0.45,0.35,,,,,,,,,,,,,, +Fixed Window 2.62/0.30/0.21,SimpleGlazing,,,,,,,,,,,0.459978667,0.3,0.21,,,,,,,,,,,,,, +Fixed Window 2.67/0.30/0.21,SimpleGlazing,,,,,,,,,,,0.469978203,0.49,0.38,,,,,,,,,,,,,, +Fixed Window 2.96/0.39/0.31,SimpleGlazing,,,,,,,,,,,0.519975884,0.39,0.31,,,,,,,,,,,,,, +Fixed Window 2.96/0.49/0.41,SimpleGlazing,,,,,,,,,,,0.519975884,0.49,0.41,,,,,,,,,,,,,, +Fixed Window 2.96/0.62/0.54,SimpleGlazing,,,,,,,,,,,0.519975884,0.62,0.54,,,,,,,,,,,,,, +Fixed Window 3.12/0.40/0.31,SimpleGlazing,,,,,,,,,,,0.55,0.4,0.31,,,,,,,,,,,,,, +Fixed Window 3.24/0.25/0.16,SimpleGlazing,,,,,,,,,,,0.569973565,0.25,0.16,,,,,,,,,,,,,, +Fixed Window 3.24/0.39/0.31,SimpleGlazing,,,,,,,,,,,0.569973565,0.39,0.31,,,,,,,,,,,,,, +Fixed Window 3.24/0.49/0.41,SimpleGlazing,,,,,,,,,,,0.569973565,0.49,0.41,,,,,,,,,,,,,, +Fixed Window 3.35/0.36/0.27,SimpleGlazing,,,,,,,,,,,0.589972638,0.36,0.27,,,,,,,,,,,,,, +Fixed Window 3.35/0.39/0.31,SimpleGlazing,,,,,,,,,,,0.589972638,0.39,0.31,,,,,,,,,,,,,, +Fixed Window 3.53/0.41/0.32,SimpleGlazing,,,,,,,,,,,0.619971246,0.41,0.32,,,,,,,,,,,,,, +Fixed Window 3.69/0.25/0.16,SimpleGlazing,,,,,,,,,,,0.65,0.25,0.16,,,,,,,,,,,,,, +Fixed Window 3.69/0.70/0.60,SimpleGlazing,,,,,,,,,,,0.65,0.7,0.6,,,,,,,,,,,,,, +Fixed Window 3.81/0.39/0.27,SimpleGlazing,,,,,,,,,,,0.519975884,0.39,0.27,,,,,,,,,,,,,, +Fixed Window 3.81/0.49/0.38,SimpleGlazing,,,,,,,,,,,0.519975884,0.49,0.38,,,,,,,,,,,,,, +Fixed Window 4.09/0.26/0.13,SimpleGlazing,,,,,,,,,,,0.719966609,0.25,0.13,,,,,,,,,,,,,, +Fixed Window 4.09/0.36/0.23,SimpleGlazing,,,,,,,,,,,0.719966609,0.36,0.23,,,,,,,,,,,,,, +Fixed Window 4.09/0.39/0.25,SimpleGlazing,,,,,,,,,,,0.719966609,0.39,0.25,,,,,,,,,,,,,, +Fixed Window 4.26/0.25/0.16,SimpleGlazing,,,,,,,,,,,0.75,0.25,0.16,,,,,,,,,,,,,, +Fixed Window 5.84/0.25/0.11,SimpleGlazing,,,,,,,,,,,1.028483473,0.25,0.11,,,,,,,,,,,,,, +Fixed Window 5.84/0.39/0.22,SimpleGlazing,,,,,,,,,,,1.028483473,0.39,0.22,,,,,,,,,,,,,, +Fixed Window 5.84/0.44/0.27,SimpleGlazing,,,,,,,,,,,1.028483473,0.44,0.27,,,,,,,,,,,,,, +Fixed Window 5.84/0.54/0.38,SimpleGlazing,,,,,,,,,,,1.028483473,0.54,0.38,,,,,,,,,,,,,, +Fixed Window 5.84/0.61/0.47,SimpleGlazing,,,,,,,,,,,1.028483473,0.61,0.47,,,,,,,,,,,,,, +Fixed Window 5.84/0.70/0.60,SimpleGlazing,,,,,,,,,,,1.028483473,0.7,0.6,,,,,,,,,,,,,, +G01 13mm gypsum board,StandardOpaqueMaterial,Smooth,0.5,1.10957004,0.450625001,49.9424,0.260516252,0.9,0.7,0.5,,,,,,,,,,,,,,,,,, +G01a 19mm gypsum board,StandardOpaqueMaterial,MediumSmooth,0.748031496,1.109355488,0.674293772,49.94236846,0.260342027,0.9,0.4,0.4,,,,,,,,,,,,,,,,,, +G05 25mm wood,StandardOpaqueMaterial,MediumSmooth,1,1.04002077,0.961519259,37.95620003,0.389318812,0.9,0.5,0.5,,,,,,,,,,,,,,,,,, +Gap_1_W_0_0018,Gas,,0.070866142,,,,,,,,Air,,,,,,,,,,,,,,,,, +Gap_1_W_0_0024,Gas,,0.094488189,,,,,,,,Air,,,,,,,,,,,,,,,,, +Gap_1_W_0_0025,Gas,,0.098425197,,,,,,,,Air,,,,,,,,,,,,,,,,, +Gap_1_W_0_0032,Gas,,0.125984252,,,,,,,,Air,,,,,,,,,,,,,,,,, +Gap_1_W_0_0038,Gas,,0.149606299,,,,,,,,Air,,,,,,,,,,,,,,,,, +Gap_1_W_0_0042,Gas,,0.165354331,,,,,,,,Air,,,,,,,,,,,,,,,,, +Gap_1_W_0_0043,Gas,,0.169291339,,,,,,,,Air,,,,,,,,,,,,,,,,, +Glass fiber batt - 10 in. R30 (CEC Default),StandardOpaqueMaterial,MediumRough,10,0.3336,29.97601918,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass fiber batt - 12 in. R38 (CEC Default),StandardOpaqueMaterial,MediumRough,12,0.3156,38.02281369,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass fiber batt - 3 1/2 in. R11 (CEC Default),StandardOpaqueMaterial,MediumRough,3.5,0.318,11.00628931,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass fiber batt - 3 1/2 in. R13 (CEC Default),StandardOpaqueMaterial,MediumRough,3.5,0.2688,13.02083333,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass fiber batt - 3 1/2 in. R15 (CEC Default),StandardOpaqueMaterial,MediumRough,3.5,0.2328,15.03436426,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass fiber batt - 4 1/2 in.,StandardOpaqueMaterial,MediumRough,4.5,0.3,15,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass fiber batt - 4 in.,StandardOpaqueMaterial,MediumRough,4,0.3,13.33333333,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass fiber batt - 5 1/2 in. R19 (CEC Default),StandardOpaqueMaterial,MediumRough,5.5,0.306,17.97385621,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass fiber batt - 5 1/2 in. R21 (CEC Default),StandardOpaqueMaterial,MediumRough,5.5,0.2616,21.02446483,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass fiber batt - 5 in.,StandardOpaqueMaterial,MediumRough,5,0.3,16.66666667,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass fiber batt - 6 1/2 in.,StandardOpaqueMaterial,MediumRough,6.5,0.3,21.66666667,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass fiber batt - 6 in.,StandardOpaqueMaterial,MediumRough,6,0.3,20,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass fiber batt - 7 1/4 in. R25 (CEC Default),StandardOpaqueMaterial,MediumRough,7.25,0.3024,23.97486772,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass fiber batt - 7 1/4 in. R30 (CEC Default),StandardOpaqueMaterial,MediumRough,7.25,0.2904,24.96556474,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass fiber batt - 8 1/4 in. R30C (CEC Default),StandardOpaqueMaterial,MediumRough,8.25,0.2748,30.02183406,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass_2010F_LayerAvg,StandardGlazing,,0.087007874,6.933471799,0.144227889,,,,,,,,,,SpectralAverage,0.434294,0.4183747,0.3410654,0.797579,0.043577,0.056031,0,0.042274,0.84,1,FALSE,, +Glass_2022F_LayerAvg,StandardGlazing,,0.153543307,6.933471799,0.144227889,,,,,,,,,,SpectralAverage,0.355897,0.3940945,0.2656452,0.677694,0.042734,0.05547,0,0.046,0.84,1,FALSE,, +Glass_2027F_LayerAvg,StandardGlazing,,0.157480315,6.933471799,,,,,,,,,,,SpectralAverage,0.369744,0.4700695,0.340935,0.765222,0.0546,0.073741,0,0.03675,0.84,1,FALSE,, +Glass_2052_LayerAvg,StandardGlazing,,0.329527559,6.933471799,,,,,,,,,,,SpectralAverage,0.507767,0.05422805,0.05449309,0.586833,0.05805,0.058397,0,0.84,0.84,1,FALSE,, +Glass_2175_LayerAvg,StandardGlazing,,0.338582677,6.933471799,0.144227889,,,,,,,,,,SpectralAverage,0.167758,0.2176064,0.4379779,0.416044,0.078729,0.10654,0,0.84,0.84,1,FALSE,, +GREEN 3MM,StandardGlazing,,0.118110236,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.635,0.063,0.063,0.822,0.075,0.075,0,0.84,0.84,1,FALSE,, +GREEN 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.487,0.056,0.056,0.749,0.07,0.07,0,0.84,0.84,1,FALSE,, +GREY 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.455,0.053,0.053,0.431,0.052,0.052,0,0.84,0.84,1,FALSE,, +Ground_Floor_R11_T2013,StandardOpaqueMaterial,Smooth,1.74123,0.15963,10.91,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +Ground_Floor_R17_T2013,StandardOpaqueMaterial,Smooth,2.71324,0.15963,17.66,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +Ground_Floor_R22_T2013,StandardOpaqueMaterial,Smooth,3.51125,0.15963,22.47,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +Gypsum Board - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,1.10004,0.454528926,40,0.27,,,,,,,,,,,,,,,,,,,,, +Gypsum Board - 1/2 in. CBES,StandardOpaqueMaterial,Smooth,0.5,1.1101,,40,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +Gypsum Board - 3/4 in.,StandardOpaqueMaterial,MediumSmooth,0.75,1.10004,0.681793389,40,0.27,,,,,,,,,,,,,,,,,,,,, +Gypsum Board - 3/8 in.,StandardOpaqueMaterial,MediumSmooth,0.38,1.10004,0.345441984,40,0.27,,,,,,,,,,,,,,,,,,,,, +Gypsum Board - 5/8 in.,StandardOpaqueMaterial,MediumSmooth,0.63,1.10004,0.572706447,40,0.27,,,,,,,,,,,,,,,,,,,,, +Gypsum Or Plaster Board - 3/8 in.,StandardOpaqueMaterial,MediumSmooth,0.374015748,4.021413643,0.093006037,49.94236846,0.260342027,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Gypsum partition block - 3 cells - 4 in. x 12 in. x 30 in. - 4 in.,StandardOpaqueMaterial,MediumRough,4,2.4,1.666666667,53.1,0.19,,,,,,,,,,,,,,,,,,,,, +Gypsum partition block - 4 cells - 3 in. x 12 in. x 30 in. - 3 in.,StandardOpaqueMaterial,MediumRough,3,2.22,1.351351351,53.1,0.19,,,,,,,,,,,,,,,,,,,,, +Gypsum partition block - solid - 3 in. x 12 in. x 30 in. - 3 in.,StandardOpaqueMaterial,MediumRough,3,2.3796,1.260716087,62.4,0.19,,,,,,,,,,,,,,,,,,,,, +Gypsum plaster - 80 lb/ft3 - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,3.2004,0.156230471,80,0.26,,,,,,,,,,,,,,,,,,,,, +Gypsum plaster - 80 lb/ft3 - 5/8 in.,StandardOpaqueMaterial,Smooth,0.63,3.2004,0.196850394,80,0.26,,,,,,,,,,,,,,,,,,,,, +Gypsum plaster - on metal lath 70 lb/ft3 - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,2.6004,0.288417167,70,0.26,,,,,,,,,,,,,,,,,,,,, +Gypsum plaster - on metal lath 80 lb/ft3 - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,3.2004,0.234345707,80,0.26,,,,,,,,,,,,,,,,,,,,, +Hard Board - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,0.72,1.041666667,50,0.31,,,,,,,,,,,,,,,,,,,,, +Hardboard - HDF - 50 lb/ft3 - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.7296,0.685307018,50,0.31,,,,,,,,,,,,,,,,,,,,, +Hardboard - HDF - 50 lb/ft3 - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,0.7296,1.027960526,50,0.31,,,,,,,,,,,,,,,,,,,,, +Hardboard - HDF - 50 lb/ft3 - 3/8 in.,StandardOpaqueMaterial,Smooth,0.38,0.7296,0.520833333,50,0.31,,,,,,,,,,,,,,,,,,,,, +Hardboard - HDF - 50 lb/ft3 - 5/8 in.,StandardOpaqueMaterial,Smooth,6.30E-01,0.7296,8.63E-01,50,0.31,,,,,,,,,,,,,,,,,,,,, +Hardwood - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,1.1604,0.861771803,42.43,0.39,,,,,,,,,,,,,,,,,,,,, +Hardwood - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,1.1604,0.430885901,42.43,0.39,,,,,,,,,,,,,,,,,,,,, +Hardwood - 3/4 in.,StandardOpaqueMaterial,MediumSmooth,0.75,1.1604,0.646328852,42.43,0.39,,,,,,,,,,,,,,,,,,,,, +HB Part. Brd - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,1.17996,0.635614767,50,0.31,,,,,,,,,,,,,,,,,,,,, +HW CONCRETE,StandardOpaqueMaterial,Rough,4,9.09153953,0.439969489,139.83872,0.2,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +HW CONCRETE 8 in,StandardOpaqueMaterial,Rough,8,9.09153953,0.879938978,139.83872,0.2,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +I01 25mm insulation board,StandardOpaqueMaterial,MediumRough,1,0.208004154,4.807596295,2.684402305,0.289003535,0.9,0.6,0.6,,,,,,,,,,,,,,,,,, +I02 50mm insulation board,StandardOpaqueMaterial,MediumRough,2,0.208004154,9.615192591,2.684402305,0.289003535,0.9,0.6,0.6,,,,,,,,,,,,,,,,,, +IEAD NonRes Roof Insulation-1.76,StandardOpaqueMaterial,MediumRough,2.912618228,0.339740118,8.573077103,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +IEAD Roof Insulation R-3.47 IP,StandardOpaqueMaterial,MediumRough,1.178836998,0.339740118,3.469819827,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 1 1/2 in. Polyurethane Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,9,0.4704,19.13265306,100.33,0.23,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 1 1/2 in. Polyurethane Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,11,0.57,19.29824561,109.36,0.22,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 2 1/2 in. EPS Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,11,0.51648,21.29801735,76.81,0.23,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 2 1/2 in. EPS Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,13,0.60612,21.44789811,86.54,0.22,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 2 in. EPS Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,10,0.6096,16.40419948,90.4,0.23,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 2 in. EPS Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,12,0.72,16.66666667,100.33,0.22,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 2 in. Polyurethane Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,10,0.4404,22.70663034,90.4,0.23,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 2 in. Polyurethane Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,12,0.5196,23.09468822,100.33,0.22,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 2 in. XPS Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,10,0.4704,21.2585034,90.4,0.23,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 2 in. XPS Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,12,0.57,21.05263158,100.33,0.22,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 3 in. EPS Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,12,0.5004,23.98081535,75.5,0.23,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 3 in. EPS Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,14,0.57,24.56140351,86.14,0.22,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 3 in. XPS Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,12,0.39,30.76923077,75.5,0.23,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 3 in. XPS Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,14,0.45,31.11111111,86.14,0.22,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 4 1/2 in. Polyurethane Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,15,0.3504,42.80821918,60.6,0.23,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 4 1/2 in. Polyurethane Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,17,0.3996,42.54254254,71.12,0.22,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 4 in. EPS Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,14,0.4296,32.58845438,64.86,0.23,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 4 in. EPS Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,16,0.5004,31.97442046,75.5,0.22,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 4 in. XPS Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,14,0.3504,39.9543379,64.86,0.23,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 4 in. XPS Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,16,0.39,41.02564103,75.5,0.22,,,,,,,,,,,,,,,,,,,,, +Insulation 1m,StandardOpaqueMaterial,Smooth,39.37,0.13876,,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +Interior Wall Addi Insul,StandardOpaqueMaterial,MediumRough,1.00E-06,0.299941999,3.33E-06,1.399999086,0.199866248,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Light Roof - 2/5 in.,StandardOpaqueMaterial,VeryRough,0.2,2.4012,0.083291687,120,0.2,,,,,,,,,,,,,,,,,,,,, +Linoleum/cork tile - 1/4 in.,StandardOpaqueMaterial,MediumRough,0.25,0.51,0.490196078,29,0.45,,,,,,,,,,,,,,,,,,,,, +LoE CLEAR 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.6,0.17,0.22,0.84,0.055,0.078,0,0.84,0.1,1,FALSE,, +LoE SPEC SEL CLEAR 3MM,StandardGlazing,,0.118110236,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.45,0.34,0.37,0.78,0.07,0.06,0,0.84,0.03,1,FALSE,, +LoE SPEC SEL CLEAR 6MM Rev,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.43,0.42,0.3,0.77,0.06,0.07,0,0.03,0.84,1,FALSE,, +LoE SPEC SEL TINT 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.26,0.14,0.41,0.46,0.06,0.04,0,0.84,0.03,1,FALSE,, +LoE TINT 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.36,0.093,0.2,0.5,0.035,0.054,0,0.84,0.1,1,FALSE,, +Loose fill - Mineral fiber - 2 lb/ft3 - 13 3/4 in.,StandardOpaqueMaterial,Rough,13.75,0.336,40.92261905,2,0.2,,,,,,,,,,,,,,,,,,,,, +Loose fill - Mineral fiber - 2 lb/ft3 - 4 in.,StandardOpaqueMaterial,Rough,4,0.336,11.9047619,2,0.2,,,,,,,,,,,,,,,,,,,,, +Loose fill - Mineral fiber - 2 lb/ft3 - 6 1/2 in.,StandardOpaqueMaterial,Rough,6.5,0.336,19.3452381,2,0.2,,,,,,,,,,,,,,,,,,,,, +Loose fill - Mineral fiber - 2 lb/ft3 - 7 1/2 in.,StandardOpaqueMaterial,Rough,7.5,0.336,22.32142857,2,0.2,,,,,,,,,,,,,,,,,,,,, +Loose fill - Mineral fiber - 2 lb/ft3 - 8 1/4 in.,StandardOpaqueMaterial,Rough,8.25,0.336,24.55357143,2,0.2,,,,,,,,,,,,,,,,,,,,, +Loose fill - Mineral fiber - closed sidewalls - 3 1/2 in.,StandardOpaqueMaterial,Rough,3.5,0.336,10.41666667,2,0.2,,,,,,,,,,,,,,,,,,,,, +M01 100mm brick,StandardOpaqueMaterial,MediumRough,4,6.170789901,0.648215231,119.8616843,0.188688258,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +M11 100mm lightweight concrete,StandardOpaqueMaterial,MediumRough,4,3.674740053,1.088512369,79.90778954,0.200630553,0.9,0.5,0.5,,,,,,,,,,,,,,,,,, +M15 200mm heavyweight concrete,StandardOpaqueMaterial,MediumRough,8,13.52027001,0.591704159,139.8386317,0.214961307,0.9,0.5,0.5,,,,,,,,,,,,,,,,,, +Maple - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,1.14,0.877192982,41.87,0.39,,,,,,,,,,,,,,,,,,,,, +Mass NonRes Wall Insulation-0.43,StandardOpaqueMaterial,MediumRough,0.017196119,0.339740118,0.050615509,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Mass Wall Insulation R-4.23 IP,StandardOpaqueMaterial,MediumRough,1.438471204,0.339740118,4.234033978,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Mastic asphalt (heavy - 20% grit) - 1 in.,StandardOpaqueMaterial,VeryRough,1,1.2996,0.769467528,59,0.22,,,,,,,,,,,,,,,,,,,,, +MAT-CC05 4 HW CONCRETE,StandardOpaqueMaterial,Rough,4,9.089781528,0.440054581,139.8386317,0.199866246,0.9,0.85,0.85,,,,,,,,,,,,,,,,,, +MAT-CC05 8 HW CONCRETE,StandardOpaqueMaterial,Rough,8,9.089781528,0.880109162,139.8386317,0.199866246,0.9,0.85,0.85,,,,,,,,,,,,,,,,,, +MAT-SHEATH,MasslessOpaqueMaterial,,,6.240124619,0.16025321,0.043699572,0.000167192,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Metal Building Semi-Cond Wall Insulation-0.54,StandardOpaqueMaterial,MediumRough,0.604172732,0.339740118,1.778337913,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Metal Building Wall Insulation R-4.14 IP,StandardOpaqueMaterial,MediumRough,1.404445223,0.339740118,4.133881011,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Metal Deck - 1/16 in.,StandardOpaqueMaterial,Smooth,0.0625,314.4,0.000198791,488.22,0.12,,,,,,,,,,,,,,,,,,,,, +Metal Decking,StandardOpaqueMaterial,MediumSmooth,0.059055118,312.0478318,0.00018925,479.4467372,0.099933123,0.9,0.6,0.6,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 16inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,9.383,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 16inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,10.756,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 16inOC - 2x6 - R0 ins.,MasslessOpaqueMaterial,,,,0.003,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 16inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,5.309,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 16inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,5.854,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 16inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,6.92,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 16inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,7.414,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 16inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,7.815,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 24inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,12.443,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 24inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,14.569,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 24inOC - 2x6 - R0 ins.,MasslessOpaqueMaterial,,,,0.003,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 24inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,6.576,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 24inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,7.544,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 24inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,9.037,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 24inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,9.564,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 24inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,10.336,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,10.16,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,10.92,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x12 - R30 ins.,MasslessOpaqueMaterial,,,,11.42,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,12.34,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x14 - R38 ins.,MasslessOpaqueMaterial,,,,12.97,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,6.01,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,6.52,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,6.96,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x4 - R19 ins.,MasslessOpaqueMaterial,,,,6.52,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,6.39,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,6.96,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x6 - R15 ins.,MasslessOpaqueMaterial,,,,8.16,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,8.26,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,8.68,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x8 - R21 ins.,MasslessOpaqueMaterial,,,,9.01,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,12.97,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,14.13,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x12 - R30 ins.,MasslessOpaqueMaterial,,,,14.65,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,16.44,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x14 - R38 ins.,MasslessOpaqueMaterial,,,,17.13,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,7.27,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,8.06,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,8.68,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x4 - R19 ins.,MasslessOpaqueMaterial,,,,8.06,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,7.61,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,8.36,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x6 - R15 ins.,MasslessOpaqueMaterial,,,,9.89,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,10.31,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,10.76,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x8 - R21 ins.,MasslessOpaqueMaterial,,,,11.42,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 16inOC - 2x4 - R0 ins.,MasslessOpaqueMaterial,,,,0.643,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 16inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,2.924,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 16inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,3.068,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 16inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,3.199,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 16inOC - 2x4 - R5 ins.,MasslessOpaqueMaterial,,,,1.309,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 16inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,3.924,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 16inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,4.078,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 16inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,4.558,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 16inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,4.71,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 16inOC - 2x8 - R25 ins.,MasslessOpaqueMaterial,,,,4.789,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 16inOC - 2x8 - R30 ins.,MasslessOpaqueMaterial,,,,4.829,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 24inOC - 2x4 - R0 ins.,MasslessOpaqueMaterial,,,,0.658,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 24inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,3.222,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 24inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,3.386,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 24inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,3.536,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 24inOC - 2x4 - R5 ins.,MasslessOpaqueMaterial,,,,1.463,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 24inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,4.558,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 24inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,4.671,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 24inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,4.996,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 24inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,5.171,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 24inOC - 2x8 - R25 ins.,MasslessOpaqueMaterial,,,,5.263,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 24inOC - 2x8 - R30 ins.,MasslessOpaqueMaterial,,,,5.309,,,,,,,,,,,,,,,,,,,,,,, +Metal Insulated Panels - 2 1/2 in.,StandardOpaqueMaterial,Smooth,2.5,0.16644,15.02042778,28.47,0.26,,,,,,,,,,,,,,,,,,,,, +Metal Insulated Panels - 2 in.,StandardOpaqueMaterial,Smooth,2,0.16704,11.97318008,34.87,0.26,,,,,,,,,,,,,,,,,,,,, +Metal Insulated Panels - 3 in.,StandardOpaqueMaterial,Smooth,3,0.16656,18.01152738,24.11,0.26,,,,,,,,,,,,,,,,,,,,, +Metal Insulated Panels - 4 in.,StandardOpaqueMaterial,Smooth,4,0.16992,23.54048964,18.54,0.26,,,,,,,,,,,,,,,,,,,,, +Metal Insulated Panels - 5 in.,StandardOpaqueMaterial,Smooth,5,0.1698,29.44640754,15.14,0.27,,,,,,,,,,,,,,,,,,,,, +Metal Insulated Panels - 6 in.,StandardOpaqueMaterial,Smooth,6,0.16584,36.17945007,12.84,0.27,,,,,,,,,,,,,,,,,,,,, +Metal Roof Insulation R-5.21 IP,StandardOpaqueMaterial,MediumRough,1.769246081,0.339740118,5.207645452,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Metal Roof Surface,StandardOpaqueMaterial,Smooth,0.031496063,313.947603,0.000100323,488.4363635,0.119422948,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Metal Roof Surface - Cool Roof,StandardOpaqueMaterial,Smooth,0.031496063,313.947603,0.000100323,488.4363635,0.119422948,0.75,0.37,0.7,,,,,,,,,,,,,,,,,, +Metal Roof Surface - Highly Reflective,StandardOpaqueMaterial,Smooth,0.031496063,313.947603,0.000100323,488.4363635,0.119422948,0.75,0.45,0.7,,,,,,,,,,,,,,,,,, +Metal Roofing,StandardOpaqueMaterial,MediumSmooth,0.059055118,312.0478318,0.00018925,479.4467372,0.099933123,0.9,0.6,0.6,,,,,,,,,,,,,,,,,, +Metal Roofing - Cool Roof,StandardOpaqueMaterial,MediumSmooth,0.059055118,312.0478318,0.00018925,479.4467372,0.099933123,0.75,0.37,0.6,,,,,,,,,,,,,,,,,, +Metal Roofing - Highly Reflective,StandardOpaqueMaterial,MediumSmooth,0.059055118,312.0478318,0.00018925,479.4467372,0.099933123,0.75,0.45,0.6,,,,,,,,,,,,,,,,,, +Metal Screw Down Roof - No Thrml Blk - R10 ins.,MasslessOpaqueMaterial,,,,5.756,,,,,,,,,,,,,,,,,,,,,,, +Metal Screw Down Roof - No Thrml Blk - R11 ins.,MasslessOpaqueMaterial,,,,6.414,,,,,,,,,,,,,,,,,,,,,,, +Metal Screw Down Roof - No Thrml Blk - R13ins.,MasslessOpaqueMaterial,,,,6.912,,,,,,,,,,,,,,,,,,,,,,, +Metal Screw Down Roof - No Thrml Blk - R16 ins.,MasslessOpaqueMaterial,,,,8.654,,,,,,,,,,,,,,,,,,,,,,, +Metal Screw Down Roof - No Thrml Blk - R19 ins.,MasslessOpaqueMaterial,,,,9.424,,,,,,,,,,,,,,,,,,,,,,, +Metal Semi-Cond Roof Insulation-1.05,StandardOpaqueMaterial,MediumRough,1.664068118,0.339740118,4.898061868,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Metal Siding,StandardOpaqueMaterial,Smooth,0.059055118,311.7288921,0.000189444,479.999849,0.097926818,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Metal Siding - 1/16 in.,StandardOpaqueMaterial,Smooth,0.0625,314.4,0.000198791,488.22,0.12,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam - 1/16 in.,StandardOpaqueMaterial,Smooth,0.0625,3.9996,0.015626563,488.22,0.12,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam - 1/16 in. CBES,StandardOpaqueMaterial,MediumRough,0.06,4.0241,,488.22,0.12,0.85,0.37,0.85,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R10 + R10 Ins.,MasslessOpaqueMaterial,,,,15.093,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R10 + R11 Ins.,MasslessOpaqueMaterial,,,,15.613,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R10 + R13 Ins.,MasslessOpaqueMaterial,,,,16.461,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R10 + R19 Ins.,MasslessOpaqueMaterial,,,,18.451,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R11 + R11 Ins.,MasslessOpaqueMaterial,,,,15.887,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R11 + R13 Ins.,MasslessOpaqueMaterial,,,,16.764,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R11 + R19 Ins.,MasslessOpaqueMaterial,,,,18.828,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R13 + R13 Ins.,MasslessOpaqueMaterial,,,,17.402,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R13 + R19 Ins.,MasslessOpaqueMaterial,,,,19.628,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R16 + R19 Ins.,MasslessOpaqueMaterial,,,,20.497,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R19 + R19 Ins.,MasslessOpaqueMaterial,,,,20.959,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - Ins. and Filled Cavity - R19 + R10 Ins.,MasslessOpaqueMaterial,,,,23.61,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - R10 ins.,MasslessOpaqueMaterial,,,,9.529,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - R11 ins.,MasslessOpaqueMaterial,,,,10.09,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - R13 ins.,MasslessOpaqueMaterial,,,,11.268,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - R16 ins.,MasslessOpaqueMaterial,,,,13.109,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - R19 ins.,MasslessOpaqueMaterial,,,,14.605,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - R6 ins.,MasslessOpaqueMaterial,,,,5.208,,,,,,,,,,,,,,,,,,,,,,, +Metal Surface,StandardOpaqueMaterial,Smooth,0.031496063,313.947603,0.000100323,488.4363635,0.119422948,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Mortar - Cement - 1 3/4 in.,StandardOpaqueMaterial,Smooth,1.76,5.01,0.351297405,116,0.2,,,,,,,,,,,,,,,,,,,,, +Mortar - Cement - 1 in.,StandardOpaqueMaterial,Smooth,1.01,5.0304,0.200779262,116,0.2,,,,,,,,,,,,,,,,,,,,, +NACM_Carpet 3/4in,StandardOpaqueMaterial,Smooth,0.75,0.34691,,18,0.33,0.9,0.7,0.9,,,,,,,,,,,,,,,,,, +NACM_Concrete 4in_140lb/ft3,StandardOpaqueMaterial,MediumRough,4,13.52932,,139.78,0.22,0.75,0.92,0.75,,,,,,,,,,,,,,,,,, +NACM_Gypsum Board 5/8in,StandardOpaqueMaterial,MediumRough,0.63,1.1101,,40,0.27,0.9,0.7,0.5,,,,,,,,,,,,,,,,,, +Nonres_Floor_Insulation,MasslessOpaqueMaterial,MediumSmooth,,,16.3699766,,,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Oak - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,1.1796,0.847744998,43.93,0.39,,,,,,,,,,,,,,,,,,,,, +OSB - Oriented Strand Board - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,0.6204,0.805931657,41,0.45,,,,,,,,,,,,,,,,,,,,, +OSB - Oriented Strand Board - 3/4 in.,StandardOpaqueMaterial,MediumSmooth,0.75,0.9096,0.824538259,41,0.45,,,,,,,,,,,,,,,,,,,,, +OSB - Oriented Strand Board - 5/8 in.,StandardOpaqueMaterial,MediumSmooth,0.63,0.7596,0.829383886,41,0.45,,,,,,,,,,,,,,,,,,,,, +Perlite board - 1 1/2 in. R3.8,StandardOpaqueMaterial,Rough,1.5,0.3996,3.753753754,10,0.2,,,,,,,,,,,,,,,,,,,,, +Perlite board - 1 in. R2.5,StandardOpaqueMaterial,Rough,1,0.3996,2.502502503,10,0.2,,,,,,,,,,,,,,,,,,,,, +Perlite board - 2 in. R5.0,StandardOpaqueMaterial,Rough,2,0.3996,5.005005005,10,0.2,,,,,,,,,,,,,,,,,,,,, +Perlite board - 3/4 in. R1.9,StandardOpaqueMaterial,Rough,0.75,0.3996,1.876876877,10,0.2,,,,,,,,,,,,,,,,,,,,, +Perlite plaster - 25 lb/ft3 - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.6,0.833333333,25,0.32,,,,,,,,,,,,,,,,,,,,, +Perlite plaster - 38 lb/ft3 - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,1.2996,0.384733764,38,0.32,,,,,,,,,,,,,,,,,,,,, +Pine (oven-dried) - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,0.6396,1.563477173,23,0.45,,,,,,,,,,,,,,,,,,,,, +Plaster/Sand Aggregate - 1 in.,StandardOpaqueMaterial,Smooth,1.01,5.0304,0.200779262,116,0.2,,,,,,,,,,,,,,,,,,,,, +Plywood - 1 1/2 in.,StandardOpaqueMaterial,MediumSmooth,1.5,0.8004,1.874062969,30,0.45,,,,,,,,,,,,,,,,,,,,, +Plywood - 1 1/4 in.,StandardOpaqueMaterial,MediumSmooth,1.25,0.8004,1.56171914,30,0.45,,,,,,,,,,,,,,,,,,,,, +Plywood - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,0.8004,1.249375312,30,0.45,,,,,,,,,,,,,,,,,,,,, +Plywood - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,0.8004,0.624687656,30,0.45,,,,,,,,,,,,,,,,,,,,, +Plywood - 1/4 in.,StandardOpaqueMaterial,MediumSmooth,0.25,0.8004,0.312343828,30,0.45,,,,,,,,,,,,,,,,,,,,, +Plywood - 3/4 in.,StandardOpaqueMaterial,MediumSmooth,0.75,0.8004,0.937031484,30,0.45,,,,,,,,,,,,,,,,,,,,, +Plywood - 3/8 in.,StandardOpaqueMaterial,MediumSmooth,0.38,0.8004,0.474762619,30,0.45,,,,,,,,,,,,,,,,,,,,, +Plywood - 5/8 in.,StandardOpaqueMaterial,MediumSmooth,0.63,0.8004,0.787106447,30,0.45,,,,,,,,,,,,,,,,,,,,, +Plywood - 5/8 in. CBES,StandardOpaqueMaterial,Smooth,0.63,0.83257,,30,0.45,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Pulpboard or paper plaster - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.5004,0.999200639,38,0.32,,,,,,,,,,,,,,,,,,,,, +PYR B CLEAR 3MM,StandardGlazing,,0.118110236,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.74,0.09,0.1,0.82,0.11,0.12,0,0.84,0.2,1,FALSE,, +PYR B CLEAR 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.68,0.09,0.1,0.81,0.11,0.12,0,0.84,0.2,1,FALSE,, +R_R30,StandardOpaqueMaterial,Smooth,4.78807,0.15963,30,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +R_R38,StandardOpaqueMaterial,Smooth,6.06489,0.15963,38,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +R_T24_2013_24.86,StandardOpaqueMaterial,Smooth,3.96771,0.15963,24.86,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +R-24 Batt Wall - 8 in. R24,StandardOpaqueMaterial,VeryRough,8,0.3336,23.98081535,1.19,0.23,,,,,,,,,,,,,,,,,,,,, +R1_R14.20,StandardOpaqueMaterial,Smooth,2.26635,0.15963,14.2,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +R2_R12.90,StandardOpaqueMaterial,Smooth,2.05887,0.15963,12.9,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +R3_R17.74,StandardOpaqueMaterial,Smooth,2.83134,0.15963,17.74,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +R4_R20.28,StandardOpaqueMaterial,Smooth,3.23667,0.15963,20.28,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +Rammed Earth,StandardOpaqueMaterial,Rough,18,1.4796,12.16545012,115,0.2,,,,,,,,,,,,,,,,,,,,, +REF A CLEAR LO 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.066,0.341,0.493,0.08,0.41,0.37,0,0.84,0.4,1,FALSE,, +REF A CLEAR MID 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.11,0.27,0.43,0.14,0.31,0.35,0,0.84,0.47,1,FALSE,, +REF A TINT MID 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.06,0.13,0.42,0.09,0.14,0.35,0,0.84,0.47,1,FALSE,, +REF B CLEAR HI 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.24,0.16,0.32,0.3,0.16,0.29,0,0.84,0.6,1,FALSE,, +REF B CLEAR LO 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.15,0.22,0.38,0.2,0.23,0.33,0,0.84,0.58,1,FALSE,, +REF B TINT HI 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.15,0.09,0.33,0.18,0.08,0.28,0,0.84,0.6,1,FALSE,, +REF B TINT MID 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.1,0.11,0.41,0.13,0.1,0.32,0,0.84,0.45,1,FALSE,, +REF C CLEAR HI 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.2,0.16,0.39,0.22,0.17,0.35,0,0.84,0.55,1,FALSE,, +REF C CLEAR MID 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.17,0.2,0.42,0.19,0.21,0.38,0,0.84,0.51,1,FALSE,, +REF D CLEAR 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.429,0.308,0.379,0.334,0.453,0.505,0,0.84,0.82,1,FALSE,, +REF D TINT 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.3,0.14,0.36,0.25,0.18,0.45,0,0.84,0.82,1,FALSE,, +Roof Gravel - 1 in.,StandardOpaqueMaterial,VeryRough,1,9.9996,0.100004,159.74,0.19,,,,,,,,,,,,,,,,,,,,, +Roof Gravel - 1/2 in.,StandardOpaqueMaterial,VeryRough,0.5,9.9996,0.050002,159.74,0.19,,,,,,,,,,,,,,,,,,,,, +Roof Insulation [18],StandardOpaqueMaterial,MediumRough,6.665354331,0.339740118,19.61897926,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Roof Membrane,StandardOpaqueMaterial,VeryRough,0.374015748,1.109355488,0.337146886,69.99984791,0.348715009,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Roof Membrane - Cool Roof,StandardOpaqueMaterial,VeryRough,0.374015748,1.109355488,0.337146886,69.99984791,0.348715009,0.75,0.37,0.7,,,,,,,,,,,,,,,,,, +Roof Membrane - Highly Reflective,StandardOpaqueMaterial,VeryRough,0.374015748,1.109355488,0.337146886,69.99984791,0.348715009,0.75,0.45,0.7,,,,,,,,,,,,,,,,,, +Roofing felt - 1/8 in.,StandardOpaqueMaterial,VeryRough,0.13,8.3004,0.015661896,141,0.3,,,,,,,,,,,,,,,,,,,,, +Rubber tile - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,0.3396,2.944640754,119,0.48,,,,,,,,,,,,,,,,,,,,, +Sand aggregate - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,5.4504,0.091736386,105,0.2,,,,,,,,,,,,,,,,,,,,, +Sand aggregate - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,5.0796,0.147649421,116,0.2,,,,,,,,,,,,,,,,,,,,, +Sand aggregate - 3/8 in.,StandardOpaqueMaterial,Smooth,0.38,5.1504,0.073780677,116,0.2,,,,,,,,,,,,,,,,,,,,, +Sand aggregate - 5/8 in.,StandardOpaqueMaterial,Smooth,0.63,5.6004,0.112491965,105,0.2,,,,,,,,,,,,,,,,,,,,, +Sand aggregate on metal lath - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,5.7696,0.129991681,105,0.2,,,,,,,,,,,,,,,,,,,,, +Shingles - Asbestos cement - lapped - 1/4 in.,StandardOpaqueMaterial,VeryRough,0.25,1.1904,0.210013441,120,0.24,,,,,,,,,,,,,,,,,,,,, +Shingles - Asphalt roll siding - 1/4 in.,StandardOpaqueMaterial,VeryRough,0.25,1.6704,0.149664751,70,0.36,,,,,,,,,,,,,,,,,,,,, +Shingles - Wood - 16 in. - 7 1/2 in. exposure - 1/2 in.,StandardOpaqueMaterial,MediumRough,0.5,0.57,0.877192982,22,0.31,,,,,,,,,,,,,,,,,,,,, +Shingles - Wood - plus insulated backer board Siding - 5/16 in.,StandardOpaqueMaterial,MediumRough,0.31,0.2196,1.411657559,22,0.31,,,,,,,,,,,,,,,,,,,,, +Siding - Asphalt insulating siding - 1/2 in. bed - 1/2 in.,StandardOpaqueMaterial,VeryRough,0.5,0.3396,1.472320377,70,0.35,,,,,,,,,,,,,,,,,,,,, +Siding - Wood - bevel - 10 in. - lapped - 3/4 in.,StandardOpaqueMaterial,Rough,0.75,0.7104,1.055743243,22,0.28,,,,,,,,,,,,,,,,,,,,, +Simple Glazing,SimpleGlazing,,,,,,,,,,,1.23,0.61,0.25,,,,,,,,,,,,,, +SIPS - Crawl Space - R22 - Double 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.24768,26.24354005,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - Crawl Space - R22 - I Joist Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.23148,28.08017971,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - Crawl Space - R22 - Single 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.23952,27.13760855,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - Crawl Space - R28 - Double 2x Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.25356,32.53667771,5.85,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - Crawl Space - R28 - I Joist Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.2436,33.86699507,5.85,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - Crawl Space - R28 - Single 2x Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.2436,33.86699507,5.85,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - Crawl Space - R33 - Double 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.1842,35.28773073,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - Crawl Space - R33 - I Joist Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.16884,38.49798626,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - Crawl Space - R33 - Single 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.16884,38.49798626,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - Crawl Space - R36 - Double 2x Spline - 10 1/4 in.,StandardOpaqueMaterial,Smooth,10.25,0.26628,38.49331531,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - Crawl Space - R36 - I Joist Spline - 10 1/4 in.,StandardOpaqueMaterial,Smooth,10.25,0.2424,42.28547855,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - Crawl Space - R36 - Single 2x Spline - 10 1/4 in.,StandardOpaqueMaterial,Smooth,10.25,0.25428,40.3098946,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - No Crawl Space - R22 - Double 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.32364,20.084044,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - No Crawl Space - R22 - I Joist Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.29772,21.83259438,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - No Crawl Space - R22 - Single 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.30636,21.21686904,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - No Crawl Space - R28 - Double 2x Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.3144,26.24045802,5.85,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - No Crawl Space - R28 - I Joist Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.29376,28.08415033,5.85,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - No Crawl Space - R28 - Single 2x Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.30408,27.13101815,5.85,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - No Crawl Space - R33 - Double 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.23148,28.08017971,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - No Crawl Space - R33 - I Joist Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.19968,32.55208333,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - No Crawl Space - R33 - Single 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.2076,31.31021195,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - No Crawl Space - R36 - Double 2x Spline - 10 1/4 in.,StandardOpaqueMaterial,Smooth,10.25,0.315,32.53968254,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - No Crawl Space - R36 - I Joist Spline - 10 1/4 in.,StandardOpaqueMaterial,Smooth,10.25,0.2904,35.29614325,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - No Crawl Space - R36 - Single 2x Spline - 10 1/4 in.,StandardOpaqueMaterial,Smooth,10.25,0.2904,35.29614325,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R14 - Double 2x Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.39312,11.44688645,9.89,0.31,,,,,,,,,,,,,,,,,,,,, +SIPS - R14 - I joist Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.35304,12.746431,9.89,0.31,,,,,,,,,,,,,,,,,,,,, +SIPS - R14 - Metal Spline - 48 in.,StandardOpaqueMaterial,Smooth,48,4.14,11.5942029,1.83,0.27,,,,,,,,,,,,,,,,,,,,, +SIPS - R14 - OSB Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.303,14.85148515,9.89,0.31,,,,,,,,,,,,,,,,,,,,, +SIPS - R14 - Single 2x Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.35868,12.54600201,9.89,0.31,,,,,,,,,,,,,,,,,,,,, +SIPS - R18 - Double 2x Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.3306,13.61161525,9.89,0.31,,,,,,,,,,,,,,,,,,,,, +SIPS - R18 - I joist Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.29208,15.40673788,9.89,0.31,,,,,,,,,,,,,,,,,,,,, +SIPS - R18 - OSB Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.25968,17.32902033,9.89,0.31,,,,,,,,,,,,,,,,,,,,, +SIPS - R18 - Single 2x Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.303,14.85148515,9.89,0.31,,,,,,,,,,,,,,,,,,,,, +SIPS - R22 - Double 2x Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.32496,20.00246184,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R22 - Double 2x Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.3828,16.98014629,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R22 - I joist Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.30216,21.51178184,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R22 - I joist Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.33696,19.29012346,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R22 - Metal Spline - 48 in.,StandardOpaqueMaterial,Smooth,48,3.0396,15.79155152,1.83,0.27,,,,,,,,,,,,,,,,,,,,, +SIPS - R22 - OSB Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.28692,22.65439844,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R22 - OSB Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.28452,22.84549417,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R22 - Single 2x Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.3096,20.99483204,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R22 - Single 2x Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.35208,18.46171325,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R28 - Double 2x Spline - 8 1/2 in.,StandardOpaqueMaterial,Smooth,8.5,0.33612,25.28858741,5.71,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R28 - Double 2x Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.37992,21.71509792,5.85,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R28 - I joist Spline - 8 1/2 in.,StandardOpaqueMaterial,Smooth,8.5,0.2976,28.56182796,5.71,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R28 - I joist Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.32364,25.49128661,5.85,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R28 - Metal Spline - 48 in.,StandardOpaqueMaterial,Smooth,48,2.45688,19.53697372,1.83,0.27,,,,,,,,,,,,,,,,,,,,, +SIPS - R28 - OSB Spline - 8 1/2 in.,StandardOpaqueMaterial,Smooth,8.5,0.2976,28.56182796,5.71,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R28 - OSB Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.27768,29.71045808,5.85,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R28 - Single 2x Spline - 8 1/2 in.,StandardOpaqueMaterial,Smooth,8.5,0.3072,27.66927083,5.71,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R28 - Single 2x Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.34236,24.09744129,5.85,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R33 - Double 2x Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.23484,27.67841935,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R33 - Double 2x Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.29928,21.71879177,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R33 - I joist Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.213,30.51643192,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R33 - I joist Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.24768,26.24354005,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R33 - OSB Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.2058,31.5840622,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R33 - OSB Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.21876,29.71292741,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R33 - Single 2x Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.213,30.51643192,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R33 - Single 2x Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.26232,24.778896,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R36 - Double 2x Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.31308,32.73923598,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R36 - Double 2x Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.3792,27.03059072,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R36 - I joist Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.2904,35.29614325,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R36 - I joist Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.32244,31.78885994,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R36 - Metal Spline - 48 in.,StandardOpaqueMaterial,Smooth,48,2.2296,21.5285253,1.83,0.27,,,,,,,,,,,,,,,,,,,,, +SIPS - R36 - OSB Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.27912,36.72255661,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R36 - OSB Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.27756,36.9289523,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R36 - Single 2x Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.30168,33.97639883,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R36 - Single 2x Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.345,29.71014493,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R44 - Double 2x Spline - 12 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,12.25,0.32016,38.26211894,4.27,0.28,,,,,,,,,,,,,,,,,,,,, +SIPS - R44 - Double 2x Spline - 12 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,12.25,0.35844,34.17587323,4.27,0.28,,,,,,,,,,,,,,,,,,,,, +SIPS - R44 - I joist Spline - 12 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,12.25,0.2802,43.71877231,4.27,0.28,,,,,,,,,,,,,,,,,,,,, +SIPS - R44 - I joist Spline - 12 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,12.25,0.31848,38.46395378,4.27,0.28,,,,,,,,,,,,,,,,,,,,, +SIPS - R44 - OSB Spline - 12 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,12.25,0.267,45.88014981,4.27,0.28,,,,,,,,,,,,,,,,,,,,, +SIPS - R44 - OSB Spline - 12 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,12.25,0.279,43.90681004,4.27,0.28,,,,,,,,,,,,,,,,,,,,, +SIPS - R44 - Single 2x Spline - 12 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,12.25,0.29352,41.73480512,4.27,0.28,,,,,,,,,,,,,,,,,,,,, +SIPS - R44 - Single 2x Spline - 12 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,12.25,0.34512,35.49490032,4.27,0.28,,,,,,,,,,,,,,,,,,,,, +SIPS - R55 - Double 2x Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.22344,45.8736126,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R55 - Double 2x Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.3,34.16666667,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R55 - I joist Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.19044,53.82272632,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R55 - I joist Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.2334,43.91602399,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R55 - OSB Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.17952,57.09670232,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R55 - OSB Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.21156,48.4496124,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R55 - Single 2x Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.20136,50.90385379,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R55 - Single 2x Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.25548,40.12055738,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +Skylight_Frame_Width_0.000_in,,,,,0,,,,,,,,,,,,,,,,,,,,,,0, +Skylight_Frame_Width_0.334_in,,,,,0.02,,,,,,,,,,,,,,,,,,,,,,0.334, +Skylight_Frame_Width_0.430_in,,,,,0.02,,,,,,,,,,,,,,,,,,,,,,0.43, +Skylight_Frame_Width_0.709_in,,,,,0.02,,,,,,,,,,,,,,,,,,,,,,0.709, +Skylight_Frame_Width_2.339_in,,,,,0.02,,,,,,,,,,,,,,,,,,,,,,2.339, +Slate - 1/2 in.,StandardOpaqueMaterial,VeryRough,0.5,11.0304,0.045329272,119.81,0.3,,,,,,,,,,,,,,,,,,,,, +Slate or tile - 1/2 in.,StandardOpaqueMaterial,VeryRough,0.5,11.0304,0.045329272,119.81,0.3,,,,,,,,,,,,,,,,,,,,, +Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 3 1/2 in.,StandardOpaqueMaterial,Rough,3.5,0.3204,10.92384519,4.6,0.34,,,,,,,,,,,,,,,,,,,,, +Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 4 1/2 in.,StandardOpaqueMaterial,Rough,4.5,0.3204,14.04494382,4.6,0.34,,,,,,,,,,,,,,,,,,,,, +Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 4 in.,StandardOpaqueMaterial,Rough,4,0.3204,12.48439451,4.6,0.34,,,,,,,,,,,,,,,,,,,,, +Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 5 1/2 in.,StandardOpaqueMaterial,Rough,5.5,0.3204,17.16604245,4.6,0.34,,,,,,,,,,,,,,,,,,,,, +Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 5 in.,StandardOpaqueMaterial,Rough,5,0.3204,15.60549313,4.6,0.34,,,,,,,,,,,,,,,,,,,,, +Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 6 1/2 in.,StandardOpaqueMaterial,Rough,6.5,0.3204,20.28714107,4.6,0.34,,,,,,,,,,,,,,,,,,,,, +Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 6 in.,StandardOpaqueMaterial,Rough,6,0.3204,18.72659176,4.6,0.34,,,,,,,,,,,,,,,,,,,,, +Spray applied - Glass fiber - 3.9 lb/ft3 - 3 1/2 in.,StandardOpaqueMaterial,MediumRough,3.5,0.27,12.96296296,3.9,0.23,,,,,,,,,,,,,,,,,,,,, +Spray applied - Glass fiber - 3.9 lb/ft3 - 4 1/2 in.,StandardOpaqueMaterial,MediumRough,4.5,0.27,16.66666667,3.9,0.23,,,,,,,,,,,,,,,,,,,,, +Spray applied - Glass fiber - 3.9 lb/ft3 - 4 in.,StandardOpaqueMaterial,MediumRough,4,0.27,14.81481481,3.9,0.23,,,,,,,,,,,,,,,,,,,,, +Spray applied - Glass fiber - 3.9 lb/ft3 - 5 1/2 in.,StandardOpaqueMaterial,MediumRough,5.5,0.27,20.37037037,3.9,0.23,,,,,,,,,,,,,,,,,,,,, +Spray applied - Glass fiber - 3.9 lb/ft3 - 5 in.,StandardOpaqueMaterial,MediumRough,5,0.27,18.51851852,3.9,0.23,,,,,,,,,,,,,,,,,,,,, +Spray applied - Glass fiber - 3.9 lb/ft3 - 6 1/2 in.,StandardOpaqueMaterial,MediumRough,6.5,0.27,24.07407407,3.9,0.23,,,,,,,,,,,,,,,,,,,,, +Spray applied - Glass fiber - 3.9 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,0.27,22.22222222,3.9,0.23,,,,,,,,,,,,,,,,,,,,, +Spray applied - Polyurethane foam - 0.5 lb/ft3 - 3 1/2 in.,StandardOpaqueMaterial,Rough,3.5,0.3,11.66666667,0.5,0.35,,,,,,,,,,,,,,,,,,,,, +Spray applied - Polyurethane foam - 0.5 lb/ft3 - 4 1/2 in.,StandardOpaqueMaterial,Rough,4.5,0.3,15,0.5,0.35,,,,,,,,,,,,,,,,,,,,, +Spray applied - Polyurethane foam - 0.5 lb/ft3 - 4 in.,StandardOpaqueMaterial,Rough,4,0.3,13.33333333,0.5,0.35,,,,,,,,,,,,,,,,,,,,, +Spray applied - Polyurethane foam - 0.5 lb/ft3 - 5 1/2 in.,StandardOpaqueMaterial,Rough,5.5,0.3,18.33333333,0.5,0.35,,,,,,,,,,,,,,,,,,,,, +Spray applied - Polyurethane foam - 0.5 lb/ft3 - 5 in.,StandardOpaqueMaterial,Rough,5,0.3,16.66666667,0.5,0.35,,,,,,,,,,,,,,,,,,,,, +Spray applied - Polyurethane foam - 0.5 lb/ft3 - 6 1/2 in.,StandardOpaqueMaterial,Rough,6.5,0.3,21.66666667,0.5,0.35,,,,,,,,,,,,,,,,,,,,, +Spray applied - Polyurethane foam - 0.5 lb/ft3 - 6 in.,StandardOpaqueMaterial,Rough,6,0.3,20,0.5,0.35,,,,,,,,,,,,,,,,,,,,, +Spray applied - Polyurethane foam - 3.0 lb/ft3 - 3 1/2 in.,StandardOpaqueMaterial,Rough,3.5,0.20004,17.4965007,3,0.35,,,,,,,,,,,,,,,,,,,,, +Spray applied - Polyurethane foam - 3.0 lb/ft3 - 4 1/2 in.,StandardOpaqueMaterial,Rough,4.5,0.20004,22.4955009,3,0.35,,,,,,,,,,,,,,,,,,,,, +Spray applied - Polyurethane foam - 3.0 lb/ft3 - 4 in.,StandardOpaqueMaterial,Rough,4,0.20004,19.9960008,3,0.35,,,,,,,,,,,,,,,,,,,,, +Spray applied - Polyurethane foam - 3.0 lb/ft3 - 5 1/2 in.,StandardOpaqueMaterial,Rough,5.5,0.20004,27.4945011,3,0.35,,,,,,,,,,,,,,,,,,,,, +Spray applied - Polyurethane foam - 3.0 lb/ft3 - 5 in.,StandardOpaqueMaterial,Rough,5,0.20004,24.995001,3,0.35,,,,,,,,,,,,,,,,,,,,, +Spray applied - Polyurethane foam - 3.0 lb/ft3 - 6 1/2 in.,StandardOpaqueMaterial,Rough,6.5,0.20004,32.4935013,3,0.35,,,,,,,,,,,,,,,,,,,,, +Spray applied - Polyurethane foam - 3.0 lb/ft3 - 6 in.,StandardOpaqueMaterial,Rough,6,0.20004,29.9940012,3,0.35,,,,,,,,,,,,,,,,,,,,, +Std Wood 6 in.,StandardOpaqueMaterial,MediumSmooth,5.905511811,0.832016616,7.097829176,33.71109871,0.289003535,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Std Wood 6inch Furnishings,StandardOpaqueMaterial,MediumSmooth,5.91,0.83257,,33.71,0.29,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Steel Frame NonRes Wall Insulation-0.73,StandardOpaqueMaterial,MediumRough,0.79835618,0.339740118,2.34990258,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Steel Frame Wall Insulation R-1.02 IP,StandardOpaqueMaterial,MediumRough,0.347890885,0.339740118,1.023991182,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Steel Frame/Cavity,StandardOpaqueMaterial,MediumRough,3.500007095,0.583217221,6.001206697,40.03997387,0.119919749,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Stone - 1 in.,StandardOpaqueMaterial,MediumRough,1,12.504,0.079974408,139.78,0.22,,,,,,,,,,,,,,,,,,,,, +Straw Bale - Int and Ext Stucco - 18 in.,StandardOpaqueMaterial,Smooth,19.5,0.6504,29.98154982,12.95,0.11,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Double glass with no low e coatings - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.81,2.802469136,29.09,0.26,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Double glass with no low e coatings - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.5304,6.165158371,20.44,0.26,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Double glass with no low e coatings - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.64764,6.901982583,15.23,0.27,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Double glass with no low e coatings - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,0.7704,7.359813084,12.22,0.27,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Double glass with no low e coatings - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,0.8904,7.715633423,10.26,0.27,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Double glass with no low e coatings - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.02,7.911764706,8.88,0.27,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Double glass with no low e coatings - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.39,4.692307692,35.69,0.26,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Double glass with no low e coatings - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.4596,5.548302872,25.92,0.26,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Single glass pane. stone. or metal pane - No Ins.,StandardOpaqueMaterial,Smooth,2.52,1.2804,1.968134958,41.9,0.26,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Single glass pane. stone. or metal pane - R10 Ins.,StandardOpaqueMaterial,Smooth,3.52,0.5904,5.962059621,30.2,0.26,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Single glass pane. stone. or metal pane - R15 Ins.,StandardOpaqueMaterial,Smooth,4.72,0.6996,6.746712407,22.79,0.26,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Single glass pane. stone. or metal pane - R20 Ins.,StandardOpaqueMaterial,Smooth,5.92,0.81324,7.27952388,18.37,0.26,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Single glass pane. stone. or metal pane - R25 Ins.,StandardOpaqueMaterial,Smooth,7.12,0.93372,7.625412329,15.45,0.27,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Single glass pane. stone. or metal pane - R30 Ins.,StandardOpaqueMaterial,Smooth,8.32,1.05,7.923809524,13.37,0.27,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Single glass pane. stone. or metal pane - R4 Ins.,StandardOpaqueMaterial,Smooth,2.08,0.48624,4.277722935,50.36,0.25,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Single glass pane. stone. or metal pane - R7 Ins.,StandardOpaqueMaterial,Smooth,2.8,0.5304,5.279034691,37.69,0.26,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Triple or low e glass - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.6504,3.490159902,29.09,0.26,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Triple or low e glass - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.51,6.411764706,20.44,0.26,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Triple or low e glass - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.63636,7.024325853,15.23,0.27,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Triple or low e glass - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,0.76476,7.414090695,12.22,0.27,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Triple or low e glass - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,0.88404,7.771141577,10.26,0.27,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Triple or low e glass - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.0104,7.986935867,8.88,0.27,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Triple or low e glass - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.36,5.083333333,35.69,0.26,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Triple or low e glass - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.43836,5.8171366,25.92,0.26,,,,,,,,,,,,,,,,,,,,, +Stucco - 3/8 in.,StandardOpaqueMaterial,Smooth,0.38,5.0004,0.07599392,115.81,0.2,,,,,,,,,,,,,,,,,,,,, +Stucco - 7/8 in.,StandardOpaqueMaterial,Smooth,0.88,4.86,0.181069959,115.81,0.2,,,,,,,,,,,,,,,,,,,,, +Stucco - 7/8 in. CBES,StandardOpaqueMaterial,MediumRough,0.88,4.85668,,115.81,0.2,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +Synthetic Stucco - EIFS finish - 1 in.,StandardOpaqueMaterial,Smooth,1,0.2496,4.006410256,1.5,0.35,,,,,,,,,,,,,,,,,,,,, +Terrazzo - 1 in.,StandardOpaqueMaterial,Rough,1,12.5004,0.07999744,160,0.19,,,,,,,,,,,,,,,,,,,,, +Test,Test,Test,0.1,0.1,0.1,0.1,0.1,0.1,0.1,0.1,,,,,,,,,,,,,,,,,, +Theoretical Glass [167],StandardGlazing,,0.118110236,14.61090512,0.06844203,,,,,,,,,,SpectralAverage,0.2374,0.7126,0.7126,0.2512,0.6988,0.6988,0,0.985,0.985,1,FALSE,, +Theoretical Glass [197],StandardGlazing,,0.118110236,0.28773908,3.475370816,,,,,,,,,,SpectralAverage,0.2349,0.7151,0.7151,0.2512,0.6988,0.6988,0,0.9,0.9,1,FALSE,, +Theoretical Glass [202],StandardGlazing,,0.118110236,0.133122659,7.511869212,,,,,,,,,,SpectralAverage,0.2325,0.7175,0.7175,0.3192,0.6308,0.6308,0,0.9,0.9,1,FALSE,, +Theoretical Glass [207],StandardGlazing,,0.118110236,0.092215175,10.84420217,,,,,,,,,,SpectralAverage,0.3311,0.6189,0.6189,0.44,0.51,0.51,0,0.9,0.9,1,FALSE,, +Theoretical Glass [216],StandardGlazing,,0.118110236,0.092215175,10.84420217,,,,,,,,,,SpectralAverage,0.3801,0.5699,0.5699,0.5079,0.4421,0.4421,0,0.9,0.9,1,FALSE,, +Theoretical Glass [221],StandardGlazing,,0.118110236,0.061707899,16.20538077,,,,,,,,,,SpectralAverage,0.4296,0.5204,0.5204,0.4503,0.4997,0.4997,0,0.9,0.9,1,FALSE,, +Theoretical Glass 297,StandardGlazing,,0.118110236,0.071803727,13.92685363,,,,,,,,,,SpectralAverage,0.375039,0.574961,0.574961,0.529698,0.420302,0.420302,0,0.9,0.9,1,FALSE,, +Theoretical Glass 347,StandardGlazing,,0.118110236,0.071816901,13.92429898,,,,,,,,,,SpectralAverage,0.315861,0.634139,0.634139,0.479911,0.470089,0.470089,0,0.9,0.9,1,FALSE,, +Tile Gap - 3/4 in.,StandardOpaqueMaterial,VeryRough,0.75,0.6612,1.13430127,70,0.24,,,,,,,,,,,,,,,,,,,,, +Typical Air Wall,MasslessOpaqueMaterial,,,6.240124619,0.16025321,0.043699572,0.000167192,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Typical Carpet Pad,MasslessOpaqueMaterial,VeryRough,,,1.229230374,,,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +Typical Insulation,MasslessOpaqueMaterial,MediumSmooth,,6.240124619,0.16025321,0.043699572,0.000167192,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +U 0.11 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.11,0.34,0.374,,,,,,,,,,,,,, +U 0.11 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.11,0.38,0.418,,,,,,,,,,,,,, +U 0.12 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.12,0.34,0.374,,,,,,,,,,,,,, +U 0.12 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.12,0.38,0.418,,,,,,,,,,,,,, +U 0.13 SHGC 0.32 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.13,0.32,0.352,,,,,,,,,,,,,, +U 0.13 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.13,0.38,0.418,,,,,,,,,,,,,, +U 0.14 SHGC 0.31 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.14,0.31,0.341,,,,,,,,,,,,,, +U 0.14 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.14,0.34,0.374,,,,,,,,,,,,,, +U 0.14 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.14,0.36,0.396,,,,,,,,,,,,,, +U 0.14 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.14,0.38,0.418,,,,,,,,,,,,,, +U 0.15 SHGC 0.31 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.15,0.31,0.341,,,,,,,,,,,,,, +U 0.15 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.15,0.34,0.374,,,,,,,,,,,,,, +U 0.17 SHGC 0.31 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.17,0.31,0.341,,,,,,,,,,,,,, +U 0.17 SHGC 0.32 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.17,0.32,0.352,,,,,,,,,,,,,, +U 0.17 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.17,0.36,0.396,,,,,,,,,,,,,, +U 0.18 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.18,0.22,0.242,,,,,,,,,,,,,, +U 0.18 SHGC 0.24 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.18,0.24,0.264,,,,,,,,,,,,,, +U 0.20 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.2,0.19,0.209,,,,,,,,,,,,,, +U 0.20 SHGC 0.20 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.2,0.2,0.22,,,,,,,,,,,,,, +U 0.20 SHGC 0.21 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.2,0.21,0.231,,,,,,,,,,,,,, +U 0.20 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.2,0.22,0.242,,,,,,,,,,,,,, +U 0.23 SHGC 0.31 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.23,0.31,0.341,,,,,,,,,,,,,, +U 0.23 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.23,0.34,0.374,,,,,,,,,,,,,, +U 0.25 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.25,0.22,0.242,,,,,,,,,,,,,, +U 0.25 SHGC 0.24 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.25,0.24,0.264,,,,,,,,,,,,,, +U 0.26 SHGC 0.40 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.26,0.4,0.44,,,,,,,,,,,,,, +U 0.29 SHGC 0.40 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.29,0.4,0.44,,,,,,,,,,,,,, +U 0.32 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.32,0.36,0.396,,,,,,,,,,,,,, +U 0.35 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.35,0.22,0.242,,,,,,,,,,,,,, +U 0.35 SHGC 0.24 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.35,0.24,0.264,,,,,,,,,,,,,, +U 0.42 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.42,0.34,0.374,,,,,,,,,,,,,, +U 0.45 SHGC 0.33 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.45,0.33,0.363,,,,,,,,,,,,,, +U 0.47 SHGC 0.33 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.47,0.33,0.363,,,,,,,,,,,,,, +U 0.48 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.48,0.19,0.209,,,,,,,,,,,,,, +U 0.48 SHGC 0.21 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.48,0.21,0.231,,,,,,,,,,,,,, +U 0.48 SHGC 0.20 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.48,0.2,0.22,,,,,,,,,,,,,, +U 0.48 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.48,0.22,0.242,,,,,,,,,,,,,, +U 0.50 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.22,0.242,,,,,,,,,,,,,, +U 0.50 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.23,0.253,,,,,,,,,,,,,, +U 0.52 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.52,0.39,0.31,,,,,,,,,,,,,, +U 0.52 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.52,0.49,0.41,,,,,,,,,,,,,, +U 0.52 SHGC 0.615 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.52,0.615,0.41,,,,,,,,,,,,,, +U 0.54 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.54,0.23,0.253,,,,,,,,,,,,,, +U 0.58 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.58,0.19,0.15,,,,,,,,,,,,,, +U 0.58 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.58,0.36,0.25,,,,,,,,,,,,,, +U 0.59 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.59,0.36,0.27,,,,,,,,,,,,,, +U 0.59 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.59,0.39,0.31,,,,,,,,,,,,,, +U 0.60 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.6,0.23,0.253,,,,,,,,,,,,,, +U 0.61 SHGC 0.77 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.61,0.77,0.6,,,,,,,,,,,,,, +U 0.62 SHGC 0.20 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.62,0.2,0.22,,,,,,,,,,,,,, +U 0.62 SHGC 0.21 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.62,0.21,0.231,,,,,,,,,,,,,, +U 0.62 SHGC 0.41 Simple Glazing,SimpleGlazing,1.22,0.54,0.38,,,,,,,,0.62,0.41,0.32,,,,,,,,,,,,,, +U 0.65 SHGC 0.35 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.65,0.35,0.25,,,,,,,,,,,,,, +U 0.69 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.69,0.19,0.15,,,,,,,,,,,,,, +U 0.69 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.69,0.36,0.23,,,,,,,,,,,,,, +U 0.69 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.69,0.39,0.23,,,,,,,,,,,,,, +U 0.69 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.69,0.49,0.38,,,,,,,,,,,,,, +U 0.69 SHGC 0.64 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.69,0.64,0.55,,,,,,,,,,,,,, +U 0.69 SHGC 0.68 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.69,0.68,0.55,,,,,,,,,,,,,, +U 0.72 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.72,0.25,0.13,,,,,,,,,,,,,, +U 0.72 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.72,0.36,0.23,,,,,,,,,,,,,, +U 0.72 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.72,0.39,0.23,,,,,,,,,,,,,, +U 0.74 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.74,0.55,0.4,,,,,,,,,,,,,, +U 0.74 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.74,0.65,0.55,,,,,,,,,,,,,, +U 0.75 SHGC 0.35 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.35,0.23,,,,,,,,,,,,,, +U 0.81 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.81,0.65,0.55,,,,,,,,,,,,,, +U 0.85 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.85,0.65,0.55,,,,,,,,,,,,,, +U 0.87 SHGC 0.58 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.87,0.58,0.55,,,,,,,,,,,,,, +U 0.87 SHGC 0.71 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.87,0.71,0.6,,,,,,,,,,,,,, +U 0.87 SHGC 0.77 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.87,0.77,0.6,,,,,,,,,,,,,, +U 0.98 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.19,0.15,,,,,,,,,,,,,, +U 0.98 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.36,0.25,,,,,,,,,,,,,, +U 1.10 SHGC 0.62 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.1,0.62,0.55,,,,,,,,,,,,,, +U 1.10 SHGC 0.77 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.1,0.77,0.6,,,,,,,,,,,,,, +U 1.15 SHGC 0.77 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.15,0.77,0.6,,,,,,,,,,,,,, +U 1.17 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.17,0.19,0.15,,,,,,,,,,,,,, +U 1.17 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.17,0.36,0.23,,,,,,,,,,,,,, +U 1.17 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.17,0.39,0.23,,,,,,,,,,,,,, +U 1.17 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.17,0.49,0.38,,,,,,,,,,,,,, +U 1.17 SHGC 0.64 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.17,0.64,0.55,,,,,,,,,,,,,, +U 1.17 SHGC 0.68 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.17,0.68,0.55,,,,,,,,,,,,,, +U 1.22 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.25,0.11,,,,,,,,,,,,,, +U 1.22 SHGC 0.54 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.54,0.38,,,,,,,,,,,,,, +U 1.30 SHGC 0.27 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.3,0.27,0.25,,,,,,,,,,,,,, +U 1.30 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.3,0.34,0.25,,,,,,,,,,,,,, +U 1.30 SHGC 0.62 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.3,0.62,0.55,,,,,,,,,,,,,, +U 1.30 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.3,0.65,0.55,,,,,,,,,,,,,, +U 1.36 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.36,0.19,0.15,,,,,,,,,,,,,, +U 1.36 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.36,0.36,0.23,,,,,,,,,,,,,, +U 1.36 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.36,0.39,0.23,,,,,,,,,,,,,, +U 1.36 SHGC 0.61 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.36,0.61,0.23,,,,,,,,,,,,,, +U 1.70 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.7,0.36,0.23,,,,,,,,,,,,,, +U 1.80 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.8,0.36,0.23,,,,,,,,,,,,,, +U 1.90 SHGC 0.27 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.9,0.27,0.25,,,,,,,,,,,,,, +U 1.90 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.9,0.34,0.25,,,,,,,,,,,,,, +U 1.90 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.9,0.39,0.25,,,,,,,,,,,,,, +U 1.90 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.9,0.65,0.25,,,,,,,,,,,,,, +U 1.98 SHGC 0.16 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.16,0.15,,,,,,,,,,,,,, +U 1.98 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.19,0.15,,,,,,,,,,,,,, +U 1.98 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.36,0.25,,,,,,,,,,,,,, +U 1.98 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.39,0.25,,,,,,,,,,,,,, +U 1.98 SHGC 0.61 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.61,0.25,,,,,,,,,,,,,, +U0.47_SHGC_0.49_SimpleGlazing_Window_05,SimpleGlazing,,,,,,,,,,Air,0.47,0.49,0.81,,,,,,,,,,,,,, +U0.47_SHGC0.46_SimpleGlazing_Window_07,SimpleGlazing,,,,,,,,,,Air,0.47,0.46,0.81,,,,,,,,,,,,,, +U0.47_SHGC0.47_SimpleGlazing_Window_06,SimpleGlazing,,,,,,,,,,Air,0.47,0.47,0.81,,,,,,,,,,,,,, +U0.47_SHGC0.47_SimpleGlazing_Window_11,SimpleGlazing,,,,,,,,,,Air,0.47,0.47,0.81,,,,,,,,,,,,,, +U0.47_SHGC0.5_SimpleGlazing_Window_03,SimpleGlazing,,,,,,,,,,Air,0.47,0.5,0.81,,,,,,,,,,,,,, +U0.77_SHGC_0.77_SimpleGlazing_Window_02,SimpleGlazing,,,,,,,,,,Air,0.77,0.77,0.81,,,,,,,,,,,,,, +U0.77_SHGC0.5_SimpleGlazing_Window_09,SimpleGlazing,,,,,,,,,,Air,0.77,0.5,0.81,,,,,,,,,,,,,, +U0.77_SHGC0.61_SimpleGlazing_Window_08,SimpleGlazing,,,,,,,,,,Air,0.77,0.61,0.81,,,,,,,,,,,,,, +U0.77_SHGC0.62_SimpleGlazing_Window_04,SimpleGlazing,,,,,,,,,,Air,0.77,0.62,0.81,,,,,,,,,,,,,, +U1.23_SHGC0.5_SimpleGlazing_Window_12,SimpleGlazing,,,,,,,,,,Air,1.23,0.5,0.81,,,,,,,,,,,,,, +U1.23_SHGC0.82_SimpleGlazing_Window_01,SimpleGlazing,,,,,,,,,,Air,1.23,0.82,0.81,,,,,,,,,,,,,, +U1.23_SHGC0.82_SimpleGlazing_Window_10,SimpleGlazing,,,,,,,,,,Air,1.23,0.62,0.81,,,,,,,,,,,,,, +Vapor permeable felt - 1/8 in.,StandardOpaqueMaterial,Rough,0.13,2.0796,0.062512022,22,0.3,,,,,,,,,,,,,,,,,,,,, +Vapor seal - 2 layers of mopped 15 lb felt - 1/4 in.,StandardOpaqueMaterial,Rough,0.25,2.0796,0.120215426,22,0.3,,,,,,,,,,,,,,,,,,,,, +Vapor seal - plastic film - 1/16 in.,StandardOpaqueMaterial,Rough,0.63,62.4996,0.010080065,30,0.3,,,,,,,,,,,,,,,,,,,,, +Vermiculite aggregate - 45 lb/ft3 - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,1.7004,0.294048459,45,0.32,,,,,,,,,,,,,,,,,,,,, +W_m1_R15,StandardOpaqueMaterial,Smooth,2.39403,0.15963,15,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +W_m2_R19,StandardOpaqueMaterial,Smooth,3.03244,0.15963,19,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +W_m3_R21,StandardOpaqueMaterial,Smooth,3.35165,0.15963,21,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +W_T24_2013_R13.99,StandardOpaqueMaterial,Smooth,2.23284,0.15963,13.99,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +W1_R8.60,StandardOpaqueMaterial,Smooth,1.37252,0.15963,8.6,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +W2_R11.13,StandardOpaqueMaterial,Smooth,1.77634,0.15963,11.13,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +W3_R11.36,StandardOpaqueMaterial,Smooth,1.81305,0.15963,11.36,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +W4_R12.62,StandardOpaqueMaterial,Smooth,2.01414,0.15963,12.62,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +Wall Insulation [31],StandardOpaqueMaterial,MediumRough,1.326771654,0.299525982,4.429571171,5.680944412,0.199914015,0.9,0.5,0.5,,,,,,,,,,,,,,,,,, +Wood - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,1.0404,0.961168781,37.94,0.39,,,,,,,,,,,,,,,,,,,,, +Wood - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,1.0404,0.480584391,37.94,0.39,,,,,,,,,,,,,,,,,,,,, +Wood - 2 in.,StandardOpaqueMaterial,MediumSmooth,2,1.0404,1.922337562,37.94,0.39,,,,,,,,,,,,,,,,,,,,, +Wood - 4 in.,StandardOpaqueMaterial,MediumSmooth,4,1.0404,3.844675125,37.94,0.39,,,,,,,,,,,,,,,,,,,,, +Wood Frame NonRes Wall Insulation-0.73,StandardOpaqueMaterial,MediumRough,0.79835618,0.339740118,2.34990258,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Wood Frame Wall Insulation R-1.61 IP,StandardOpaqueMaterial,MediumRough,0.54621365,0.339740118,1.607739625,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x10 - R11 ins.,MasslessOpaqueMaterial,,,,10.783,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x10 - R13 ins.,MasslessOpaqueMaterial,,,,12.4765,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x10 - R19 ins.,MasslessOpaqueMaterial,,,,17.1561,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x10 - R21 ins.,MasslessOpaqueMaterial,,,,18.5953,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x10 - R22 ins.,MasslessOpaqueMaterial,,,,19.2942,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,21.3129,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,24.4379,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x10 - R38 ins.,MasslessOpaqueMaterial,,,,28.8982,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x10 - R44 ins.,MasslessOpaqueMaterial,,,,31.873,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x10 - R49 ins.,MasslessOpaqueMaterial,,,,34.1444,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x10 - R60 ins.,MasslessOpaqueMaterial,,,,38.5802,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x12 - R11 ins.,MasslessOpaqueMaterial,,,,11.0136,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x12 - R13 ins.,MasslessOpaqueMaterial,,,,12.7862,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x12 - R19 ins.,MasslessOpaqueMaterial,,,,17.7471,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x12 - R21 ins.,MasslessOpaqueMaterial,,,,19.2917,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x12 - R22 ins.,MasslessOpaqueMaterial,,,,20.045,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x12 - R25 ins.,MasslessOpaqueMaterial,,,,22.2328,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x12 - R30 ins.,MasslessOpaqueMaterial,,,,25.6551,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,30.6158,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x12 - R44 ins.,MasslessOpaqueMaterial,,,,33.9752,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x12 - R49 ins.,MasslessOpaqueMaterial,,,,36.5684,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x12 - R60 ins.,MasslessOpaqueMaterial,,,,41.7037,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,9.0352,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,10.1946,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x4 - R19 ins.,MasslessOpaqueMaterial,,,,13.1185,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x4 - R21 ins.,MasslessOpaqueMaterial,,,,13.9437,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x4 - R22 ins.,MasslessOpaqueMaterial,,,,14.333,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x4 - R25 ins.,MasslessOpaqueMaterial,,,,15.4178,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x4 - R30 ins.,MasslessOpaqueMaterial,,,,16.9895,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x4 - R38 ins.,MasslessOpaqueMaterial,,,,19.0316,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x4 - R44 ins.,MasslessOpaqueMaterial,,,,20.278,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x4 - R49 ins.,MasslessOpaqueMaterial,,,,21.1742,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x4 - R60 ins.,MasslessOpaqueMaterial,,,,22.7998,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,9.98167,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,11.416,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,15.2129,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,16.3338,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x6 - R22 ins.,MasslessOpaqueMaterial,,,,16.8706,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x6 - R25 ins.,MasslessOpaqueMaterial,,,,18.394,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x6 - R30 ins.,MasslessOpaqueMaterial,,,,20.6759,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x6 - R38 ins.,MasslessOpaqueMaterial,,,,23.7814,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x6 - R44 ins.,MasslessOpaqueMaterial,,,,25.7599,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x6 - R49 ins.,MasslessOpaqueMaterial,,,,27.2236,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x6 - R60 ins.,MasslessOpaqueMaterial,,,,29.9711,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x8 - R11 ins.,MasslessOpaqueMaterial,,,,10.4438,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x8 - R13 ins.,MasslessOpaqueMaterial,,,,12.0246,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,16.313,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x8 - R21 ins.,MasslessOpaqueMaterial,,,,17.6089,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,18.2344,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x8 - R25 ins.,MasslessOpaqueMaterial,,,,20.0271,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x8 - R30 ins.,MasslessOpaqueMaterial,,,,22.7622,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x8 - R38 ins.,MasslessOpaqueMaterial,,,,26.584,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x8 - R44 ins.,MasslessOpaqueMaterial,,,,29.0808,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x8 - R49 ins.,MasslessOpaqueMaterial,,,,30.96,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x8 - R60 ins.,MasslessOpaqueMaterial,,,,34.5633,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x10 - R11 ins.,MasslessOpaqueMaterial,,,,10.8472,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x10 - R13 ins.,MasslessOpaqueMaterial,,,,12.6291,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x10 - R19 ins.,MasslessOpaqueMaterial,,,,17.6705,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x10 - R21 ins.,MasslessOpaqueMaterial,,,,19.2568,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x10 - R22 ins.,MasslessOpaqueMaterial,,,,20.0334,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,22.2995,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,25.8772,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x10 - R38 ins.,MasslessOpaqueMaterial,,,,31.1355,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x10 - R44 ins.,MasslessOpaqueMaterial,,,,34.7459,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x10 - R49 ins.,MasslessOpaqueMaterial,,,,37.5607,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x10 - R60 ins.,MasslessOpaqueMaterial,,,,43.2077,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x12 - R11 ins.,MasslessOpaqueMaterial,,,,11.0095,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x12 - R13 ins.,MasslessOpaqueMaterial,,,,12.8496,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x12 - R19 ins.,MasslessOpaqueMaterial,,,,18.1053,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x12 - R21 ins.,MasslessOpaqueMaterial,,,,19.7743,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x12 - R22 ins.,MasslessOpaqueMaterial,,,,20.594,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x12 - R25 ins.,MasslessOpaqueMaterial,,,,22.9964,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x12 - R30 ins.,MasslessOpaqueMaterial,,,,26.8204,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,32.5111,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x12 - R44 ins.,MasslessOpaqueMaterial,,,,36.4678,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x12 - R49 ins.,MasslessOpaqueMaterial,,,,39.581,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x12 - R60 ins.,MasslessOpaqueMaterial,,,,45.903,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,9.54677,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,10.9003,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x4 - R19 ins.,MasslessOpaqueMaterial,,,,14.4614,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x4 - R21 ins.,MasslessOpaqueMaterial,,,,15.5068,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x4 - R22 ins.,MasslessOpaqueMaterial,,,,16.0065,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x4 - R25 ins.,MasslessOpaqueMaterial,,,,17.421,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x4 - R30 ins.,MasslessOpaqueMaterial,,,,19.5305,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x4 - R38 ins.,MasslessOpaqueMaterial,,,,22.3835,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x4 - R44 ins.,MasslessOpaqueMaterial,,,,24.1906,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x4 - R49 ins.,MasslessOpaqueMaterial,,,,25.5222,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x4 - R60 ins.,MasslessOpaqueMaterial,,,,28.0096,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,10.2668,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,11.8491,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,16.1804,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,17.5004,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x6 - R22 ins.,MasslessOpaqueMaterial,,,,18.1394,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x6 - R25 ins.,MasslessOpaqueMaterial,,,,19.9777,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x6 - R30 ins.,MasslessOpaqueMaterial,,,,22.802,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x6 - R38 ins.,MasslessOpaqueMaterial,,,,26.7885,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x6 - R44 ins.,MasslessOpaqueMaterial,,,,29.4185,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x6 - R49 ins.,MasslessOpaqueMaterial,,,,31.4116,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x6 - R60 ins.,MasslessOpaqueMaterial,,,,35.2661,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x8 - R11 ins.,MasslessOpaqueMaterial,,,,10.6047,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x8 - R13 ins.,MasslessOpaqueMaterial,,,,12.3015,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,17.0358,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x8 - R21 ins.,MasslessOpaqueMaterial,,,,18.5054,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,19.2214,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x8 - R25 ins.,MasslessOpaqueMaterial,,,,21.298,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x8 - R30 ins.,MasslessOpaqueMaterial,,,,24.5383,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x8 - R38 ins.,MasslessOpaqueMaterial,,,,29.2172,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x8 - R44 ins.,MasslessOpaqueMaterial,,,,32.3739,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x8 - R49 ins.,MasslessOpaqueMaterial,,,,34.804,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x8 - R60 ins.,MasslessOpaqueMaterial,,,,39.5997,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 16inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,21.3129,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 16inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,24.4379,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 16inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,30.6158,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 16inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,9.98167,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 16inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,11.416,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 16inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,15.2129,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 16inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,16.313,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 16inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,18.2344,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 24inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,22.2995,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 24inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,25.8772,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 24inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,32.5111,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 24inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,10.2668,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 24inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,11.8491,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 24inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,16.1804,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 24inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,17.0358,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 24inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,19.2214,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x10 - R22 ins.,MasslessOpaqueMaterial,,,,19.2942,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,21.3129,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,24.4379,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x12 - R30 ins.,MasslessOpaqueMaterial,,,,25.6551,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,30.6158,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x14 - R38 ins.,MasslessOpaqueMaterial,,,,30.6158,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,9.0352,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,10.1946,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,11.2537,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x4 - R19 ins.,MasslessOpaqueMaterial,,,,13.1185,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,9.98167,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,11.416,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x6 - R15 ins.,MasslessOpaqueMaterial,,,,12.7607,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,15.2129,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,16.3338,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,16.313,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x8 - R21 ins.,MasslessOpaqueMaterial,,,,17.6089,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x10 - R22 ins.,MasslessOpaqueMaterial,,,,20.0334,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,22.2995,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,25.8772,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x12 - R30 ins.,MasslessOpaqueMaterial,,,,26.8204,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,32.5111,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x14 - R38 ins.,MasslessOpaqueMaterial,,,,32.5111,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,9.54677,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,10.9003,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,12.1652,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x4 - R19 ins.,MasslessOpaqueMaterial,,,,14.4614,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,10.2668,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,11.8491,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x6 - R15 ins.,MasslessOpaqueMaterial,,,,13.359,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,16.1804,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,17.5004,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,17.0358,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x8 - R21 ins.,MasslessOpaqueMaterial,,,,18.5054,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 16inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,7.12596,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 16inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,7.70165,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 16inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,8.18665,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 16inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,11.7113,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 16inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,12.2507,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 16inOC - 2x6 - R22 ins.,MasslessOpaqueMaterial,,,,12.4993,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 16inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,13.4581,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 16inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,14.5092,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 16inOC - 2x8 - R25 ins.,MasslessOpaqueMaterial,,,,15.4247,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 16inOC - 2x8 - R30 ins.,MasslessOpaqueMaterial,,,,16.7137,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,7.44041,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x4 - R11 ins. AWS,MasslessOpaqueMaterial,,,,8.03106,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,8.09769,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x4 - R13 ins. AWS,MasslessOpaqueMaterial,,,,8.85675,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,8.6586,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x4 - R15 ins. AWS,MasslessOpaqueMaterial,,,,9.57897,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,12.2765,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x6 - R19 ins. AWS,MasslessOpaqueMaterial,,,,13.3502,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,12.8954,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x6 - R21 ins. AWS,MasslessOpaqueMaterial,,,,14.1353,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x6 - R22 ins.,MasslessOpaqueMaterial,,,,13.1824,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x6 - R22 ins. AWS,MasslessOpaqueMaterial,,,,14.5036,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,13.9462,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x8 - R19 ins. AWS,MasslessOpaqueMaterial,,,,14.8435,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,15.1272,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x8 - R22 ins. AWS,MasslessOpaqueMaterial,,,,16.2834,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x8 - R25 ins.,MasslessOpaqueMaterial,,,,16.1678,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x8 - R25 ins. AWS,MasslessOpaqueMaterial,,,,17.5793,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x8 - R30 ins.,MasslessOpaqueMaterial,,,,17.6518,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x8 - R30 ins. AWS,MasslessOpaqueMaterial,,,,19.4735,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 48inOC - 2x4 - R11 ins. AWS,MasslessOpaqueMaterial,,,,10.1197,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 48inOC - 2x4 - R13 ins. AWS,MasslessOpaqueMaterial,,,,11.711,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 48inOC - 2x4 - R15 ins. AWS,MasslessOpaqueMaterial,,,,13.2373,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 48inOC - 2x6 - R19 ins. AWS,MasslessOpaqueMaterial,,,,17.2794,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 48inOC - 2x6 - R21 ins. AWS,MasslessOpaqueMaterial,,,,18.8464,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 48inOC - 2x6 - R22 ins. AWS,MasslessOpaqueMaterial,,,,19.6146,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 48inOC - 2x8 - R19 ins. AWS,MasslessOpaqueMaterial,,,,17.8255,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 48inOC - 2x8 - R22 ins. AWS,MasslessOpaqueMaterial,,,,20.3213,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 48inOC - 2x8 - R25 ins. AWS,MasslessOpaqueMaterial,,,,22.7412,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 48inOC - 2x8 - R30 ins. AWS,MasslessOpaqueMaterial,,,,26.6149,,,,,,,,,,,,,,,,,,,,,,, +Wood shingles - 3/4 in.,StandardOpaqueMaterial,VeryRough,0.75,0.8304,0.903179191,36.94,0.31,,,,,,,,,,,,,,,,,,,,, +Wood shingles - plain and plastic film faced - 3/4 in.,StandardOpaqueMaterial,VeryRough,0.75,0.8004,0.937031484,22,0.31,,,,,,,,,,,,,,,,,,,,, +Wood Siding,StandardOpaqueMaterial,MediumSmooth,0.393700787,0.762681898,0.516205758,33.99951589,0.289003535,0.9,0.78,0.78,,,,,,,,,,,,,,,,,, +Wood siding - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,0.6204,0.805931657,36.94,0.28,,,,,,,,,,,,,,,,,,,,, +U 0.49 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.49,0.22,,,,,,,,,,,,,,, +U 0.57 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.57,0.25,,,,,,,,,,,,,,, +U 0.53 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.53,0.25,,,,,,,,,,,,,,, +U 0.48 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.48,0.25,,,,,,,,,,,,,,, +U 0.38 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.38,0.36,,,,,,,,,,,,,,, +U 0.38 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.38,0.38,,,,,,,,,,,,,,, +U 0.36 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.36,0.4,,,,,,,,,,,,,,, +U 0.33 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.33,0.45,,,,,,,,,,,,,,, +U 0.29 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.29,0.45,,,,,,,,,,,,,,, +U 0.5 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.22,,,,,,,,,,,,,,, +U 0.54 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.54,0.25,,,,,,,,,,,,,,, +U 0.49 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.49,0.25,,,,,,,,,,,,,,, +U 0.45 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.45,0.25,,,,,,,,,,,,,,, +U 1.19 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.19,0.45,,,,,,,,,,,,,,, +U 0.73 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.73,0.45,,,,,,,,,,,,,,, +U 0.62 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.62,0.45,,,,,,,,,,,,,,, +U 0.51 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.51,0.45,,,,,,,,,,,,,,, +U 0.38 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.38,0.45,,,,,,,,,,,,,,, +U 0.53 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.53,0.22,,,,,,,,,,,,,,, +U 0.53 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.53,0.23,,,,,,,,,,,,,,, +U 0.38 SHGC 0.35 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.38,0.35,,,,,,,,,,,,,,, +U 0.38 SHGC 0.37 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.38,0.37,,,,,,,,,,,,,,, +U 0.36 SHGC 0.37 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.36,0.37,,,,,,,,,,,,,,, +U 0.31 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.31,0.39,,,,,,,,,,,,,,, +U 0.28 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.28,0.39,,,,,,,,,,,,,,, +U 0.51 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.51,0.22,,,,,,,,,,,,,,, +U 0.51 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.51,0.23,,,,,,,,,,,,,,, +U 0.46 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.46,0.25,,,,,,,,,,,,,,, +U 0.43 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.43,0.25,,,,,,,,,,,,,,, +U 0.36 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.36,0.36,,,,,,,,,,,,,,, +U 0.36 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.36,0.38,,,,,,,,,,,,,,, +U 0.34 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.34,0.38,,,,,,,,,,,,,,, +U 0.29 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.29,0.4,,,,,,,,,,,,,,, +U 0.26 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.26,0.4,,,,,,,,,,,,,,, +U 0.37 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.37,0.36,,,,,,,,,,,,,,, +U 0.37 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.37,0.38,,,,,,,,,,,,,,, +U 0.35 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.35,0.38,,,,,,,,,,,,,,, +U 0.3 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.3,0.4,,,,,,,,,,,,,,, +U 0.27 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.27,0.4,,,,,,,,,,,,,,, +U 0.5 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.23,,,,,,,,,,,,,,, +U 0.42 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.42,0.25,,,,,,,,,,,,,,, +U 0.47 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.47,0.25,,,,,,,,,,,,,,, +U 1.2 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.2,0.45,,,,,,,,,,,,,,, +U 0.5 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.45,,,,,,,,,,,,,,, +U 0.39 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.39,0.45,,,,,,,,,,,,,,, +U 0.36 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.36,0.45,,,,,,,,,,,,,,, +U 0.75 SHGC 0.35 Simple Glazing Window,SimpleGlazing,,,,,,,,,,,0.75,0.35,,,,,,,,,,,,,,, +U 0.65 SHGC 0.35 Simple Glazing Window,SimpleGlazing,,,,,,,,,,,0.65,0.35,,,,,,,,,,,,,,, +U 0.55 SHGC 0.35 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.55,0.35,,,,,,,,,,,,,,, +U 0.5 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.4,,,,,,,,,,,,,,, +U 0.5 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.55,,,,,,,,,,,,,,, +U 0.41 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.41,0.55,,,,,,,,,,,,,,, +U 1.8 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.8,0.55,,,,,,,,,,,,,,, +U 1.7 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.7,0.55,,,,,,,,,,,,,,, +U 1.15 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.15,0.55,,,,,,,,,,,,,,, +U 0.98 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.55,,,,,,,,,,,,,,, +U 0.85 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.85,0.55,,,,,,,,,,,,,,, +U 0.7 SHGC 0.3 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.7,0.3,,,,,,,,,,,,,,, +U 0.65 SHGC 0.3 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.65,0.3,,,,,,,,,,,,,,, +U 0.55 SHGC 0.3 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.55,0.3,,,,,,,,,,,,,,, +U 0.47 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.47,0.4,,,,,,,,,,,,,,, +U 0.44 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.44,0.55,,,,,,,,,,,,,,, +U 0.9 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.9,0.55,,,,,,,,,,,,,,, +U 0.75 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.55,,,,,,,,,,,,,,, +U 0.37 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.37,0.25,,,,,,,,,,,,,,, +U 0.83 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.83,0.25,,,,,,,,,,,,,,, +U 0.77 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.77,0.25,,,,,,,,,,,,,,, +U 0.93 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.93,0.45,,,,,,,,,,,,,,, +U 0.83 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.83,0.45,,,,,,,,,,,,,,, +U 0.65 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.65,0.55,,,,,,,,,,,,,,, +U 1.8 SHGC 0.77 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.8,0.77,,,,,,,,,,,,,,, +U 0.65 SHGC 0.77 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.65,0.77,,,,,,,,,,,,,,, +U 0.65 SHGC 0.68 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.65,0.68,,,,,,,,,,,,,,, +U 1.8 SHGC 0.64 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.8,0.64,,,,,,,,,,,,,,, +U 0.33 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.33,0.25,,,,,,,,,,,,,,, +U 0.68 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.68,0.25,,,,,,,,,,,,,,, +U 0.87 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.87,0.45,,,,,,,,,,,,,,, +U 0.77 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.77,0.45,,,,,,,,,,,,,,, +U 0.55 SHGC 0.64 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.55,0.64,,,,,,,,,,,,,,, +U 0.55 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.55,0.55,,,,,,,,,,,,,,, +U 0.31 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.31,0.36,,,,,,,,,,,,,,, +U 0.68 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.68,0.36,,,,,,,,,,,,,,, +U 0.31 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.31,0.38,,,,,,,,,,,,,,, +U 0.68 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.68,0.38,,,,,,,,,,,,,,, +U 0.45 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.45,0.45,,,,,,,,,,,,,,, +U 0.5 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.36,,,,,,,,,,,,,,, +U 0.5 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.19,,,,,,,,,,,,,,, +U 0.5 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.34,,,,,,,,,,,,,,, +U 0.98 SHGC 0.27 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.27,,,,,,,,,,,,,,, +U 0.98 SHGC 0.36 Simple Glazing Weighted,SimpleGlazing,,,,,,,,,,,0.98,0.36,,,,,,,,,,,,,,, +U 0.68 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.68,0.4,,,,,,,,,,,,,,, +U 0.85 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.85,0.19,,,,,,,,,,,,,,, +U 0.85 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.85,0.39,,,,,,,,,,,,,,, +U 0.28 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.28,0.45,,,,,,,,,,,,,,, +U 0.68 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.68,0.45,,,,,,,,,,,,,,, +U 0.32 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.32,0.45,,,,,,,,,,,,,,, +U 0.5 SHGC 0.27 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.27,,,,,,,,,,,,,,, +U 0.25 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.25,0.45,,,,,,,,,,,,,,, +U 0.5 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.39,,,,,,,,,,,,,,, +U 0.5 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.65,,,,,,,,,,,,,,, +U 0.85 SHGC 0.27 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.85,0.27,,,,,,,,,,,,,,, +U 0.5 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.25,,,,,,,,,,,,,,, +U 1.1 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.1,0.25,,,,,,,,,,,,,,, +U 1.1 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.1,0.45,,,,,,,,,,,,,,, +U 0.75 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.49,,,,,,,,,,,,,,, +U 1.8 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.8,0.49,,,,,,,,,,,,,,, +U 0.75 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.39,,,,,,,,,,,,,,, +U 0.75 SHGC 0.68 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.68,,,,,,,,,,,,,,, +U 0.75 SHGC 0.64 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.64,,,,,,,,,,,,,,, +U 0.77 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.77,0.23,,,,,,,,,,,,,,, +U 0.68 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.68,0.23,,,,,,,,,,,,,,, +U 0.63 SHGC 0.33 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.63,0.33,,,,,,,,,,,,,,, +U 0.63 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.63,0.34,,,,,,,,,,,,,,, +U 0.63 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.63,0.36,,,,,,,,,,,,,,, +U 0.63 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.63,0.45,,,,,,,,,,,,,,, +U 0.83 SHGC 0.21 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.83,0.21,,,,,,,,,,,,,,, +U 0.32 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.32,0.22,,,,,,,,,,,,,,, +U 0.83 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.83,0.22,,,,,,,,,,,,,,, +U 0.83 SHGC 0.2 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.83,0.2,,,,,,,,,,,,,,, +U 0.6 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.6,0.23,,,,,,,,,,,,,,, +U 0.62 SHGC 0.2 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.62,0.2,,,,,,,,,,,,,,, +U 1.22 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.19,,,,,,,,,,,,,,, +U 1.22 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.45,,,,,,,,,,,,,,, +U 1.22 SHGC 0.17 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.17,,,,,,,,,,,,,,, +U 1.22 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.39,,,,,,,,,,,,,,, +U 0.98 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.45,,,,,,,,,,,,,,, +U 1.98 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.45,,,,,,,,,,,,,,, +U 0.57 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.57,0.39,,,,,,,,,,,,,,, +U 0.46 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.46,0.19,,,,,,,,,,,,,,, +U 1.98 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.34,,,,,,,,,,,,,,, +U 1.22 SHGC 0.61 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.61,,,,,,,,,,,,,,, +U 1.22 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.34,,,,,,,,,,,,,,, +U 0.57 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.57,0.49,,,,,,,,,,,,,,, +U 0.46 SHGC 0.26 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.46,0.26,,,,,,,,,,,,,,, +U 1.98 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.65,,,,,,,,,,,,,,, +U 0.58 SHGC 0.61 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.58,0.61,,,,,,,,,,,,,,, +U 0.46 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.46,0.36,,,,,,,,,,,,,,, +U 0.46 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.46,0.45,,,,,,,,,,,,,,, +U 0.35 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.35,0.45,,,,,,,,,,,,,,, +U 0.98 SHGC 0.62 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.62,,,,,,,,,,,,,,, +U 0.58 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.58,0.45,,,,,,,,,,,,,,, +U 0.75 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.25,,,,,,,,,,,,,,, +U 0.7 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.7,0.25,,,,,,,,,,,,,,, +U 1.98 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.49,,,,,,,,,,,,,,, +U 0.65 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.65,0.25,,,,,,,,,,,,,,, +U 0.6 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.6,0.25,,,,,,,,,,,,,,, +U 0.9 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.9,0.25,,,,,,,,,,,,,,, +U 1.98 SHGC 0.71 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.71,,,,,,,,,,,,,,, +U 0.4 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.4,0.4,,,,,,,,,,,,,,, +U 0.55 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.55,0.4,,,,,,,,,,,,,,, +U 0.85 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.85,0.4,,,,,,,,,,,,,,, +U 0.35 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.35,0.4,,,,,,,,,,,,,,, +U 0.45 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.45,0.4,,,,,,,,,,,,,,, +U 0.8 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.8,0.4,,,,,,,,,,,,,,, +U 0.65 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.65,0.45,,,,,,,,,,,,,,, +U 0.6 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.6,0.45,,,,,,,,,,,,,,, +U 0.9 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.9,0.45,,,,,,,,,,,,,,, +U 0.4 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.4,0.45,,,,,,,,,,,,,,, +U 0.8 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.8,0.45,,,,,,,,,,,,,,, +U 1.2 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.2,0.25,,,,,,,,,,,,,,, +U 1.98 SHGC 0.27 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.27,,,,,,,,,,,,,,, +U 1.17 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.17,0.45,,,,,,,,,,,,,,, +U 0.98 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.49,,,,,,,,,,,,,,, +U 0.98 SHGC 0.46 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.46,,,,,,,,,,,,,,, +U 0.58 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.58,0.65,,,,,,,,,,,,,,, +U 0.58 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.58,0.55,,,,,,,,,,,,,,, +U 0.4 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.4,0.25,,,,,,,,,,,,,,, +U 0.35 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.35,0.25,,,,,,,,,,,,,,, +U 0.55 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.55,0.45,,,,,,,,,,,,,,, +U 0.42 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.42,0.4,,,,,,,,,,,,,,, +U 0.77 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.77,0.4,,,,,,,,,,,,,,, +U 0.81 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.81,0.45,,,,,,,,,,,,,,, +U 0.32 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.32,0.4,,,,,,,,,,,,,,, +U 0.7 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.7,0.45,,,,,,,,,,,,,,, +U 0.59 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.59,0.45,,,,,,,,,,,,,,, +U 0.44 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.44,0.45,,,,,,,,,,,,,,, +U 0.93 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.93,0.25,,,,,,,,,,,,,,, +U 0.75 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.45,,,,,,,,,,,,,,, +U 0.48 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.48,0.45,,,,,,,,,,,,,,, diff --git a/data/openstudio_standards_data/initial_data/support_performance_curves.csv b/data/openstudio_standards_data/initial_data/support_performance_curves.csv new file mode 100644 index 0000000000..831e7d15c5 --- /dev/null +++ b/data/openstudio_standards_data/initial_data/support_performance_curves.csv @@ -0,0 +1,734 @@ +name,category,form,dependent_variable,independent_variable_1,independent_variable_2,coeff_1,coeff_2,coeff_3,coeff_4,coeff_5,coeff_6,coeff_7,coeff_8,coeff_9,coeff_10,minimum_independent_variable_1,maximum_independent_variable_1,minimum_independent_variable_2,maximum_independent_variable_2,minimum_dependent_variable_output,maximum_dependent_variable_output,annotation +a-Si_Spectral-fAirMass,PV-Module,Cubic,,AirMass,,0.99264449,0.05334853,-0.0372019,0.00327026,,,,,,,,,,,,,From .dat files included with MASControl2 +Absor-1-Cap-fCHWT&ECT,1-StageAbsorptn,BiQuadratic,QRatio,CHWT,ECT,1.757428,0.054774,-0.00290628,-0.035145,-0.000156,0.000894,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Absor-1-HIR-fCHWT&ECT,1-StageAbsorptn,BiQuadratic,,CHWT,ECT,0.691153,0,0,0.005355,0.000178,0,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Absor-1-HIR-fPLR,1-StageAbsorptn,Quadratic,,PLR,,0.087773,0.744921,0.167306,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Absor-2-Cap-fCHWT&ECT,2-StageAbsorptn,BiQuadratic,QRatio,CHWT,ECT,0.362073,0.0001386,0.001458,0.0733878,-0.00206064,0.00101,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Absor-2-HIR-fCHWT&ECT,2-StageAbsorptn,BiQuadratic,,CHWT,ECT,0.98675,0,0,-0.0234,0.00081,0,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Absor-2-HIR-fPLR,2-StageAbsorptn,Quadratic,,PLR,,0.1355115,0.61798084,0.24651277,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +AHU-1_CoolCStandard10Ton_CapFF,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.77136,0.34053,-0.11088,,,,,,,,0.75918,1.13877,,,,,"From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" +AirCooled_Chiller_2004_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.0433811,0.0407077,0.0004506,-0.0041514,-0.0000886,-0.0003467,,,,,5,10,12.7,51.67,,,"Based on Dick Lord's study dated January 17, 2010." +AirCooled_Chiller_2004_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.5961915,-0.0099496,0.0007888,0.0004506,0.0004875,-0.0007623,,,,,5,10,12.7,51.67,,,"Based on Dick Lord's study dated January 17, 2010." +AirCooled_Chiller_2010_PathA_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.0433825,0.0407073,0.0004506,-0.0041514,-0.0000886,-0.0003467,,,,,5,10,12.7,51.67,,,"Based on Dick Lord's study dated January 17, 2010." +AirCooled_Chiller_2010_PathA_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.5961915,-0.0099496,0.0007888,0.0004506,0.0004875,-0.0007623,,,,,5,10,12.7,51.67,,,"Based on Dick Lord's study dated January 17, 2010." +AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.141,0.655,0.203,,,,,,,,0,1,,,,,"Based on Dick Lord's study dated January 17, 2010. EIRFPLR curve is identical for all AirCooled Chillers" +AirCooled_Chiller_GT150_2004_EIRFPLR,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.141,0.655,0.203,,,,,,,,0,1,,,,,"Based on Dick Lord's study dated January 17, 2010." +AirCooled_Chiller_GT150_2010_PathA_EIRFPLR,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.141,0.655,0.203,,,,,,,,0,1,,,,,"Based on Dick Lord's study dated January 17, 2010." +AirCooled_Chiller_LT150_2004_EIRFPLR,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.141,0.655,0.203,,,,,,,,0,1,,,,,"Based on Dick Lord's study dated January 17, 2010." +AirCooled_Chiller_LT150_2010_PathA_EIRFPLR,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.141,0.655,0.203,,,,,,,,0,1,,,,,"Based on Dick Lord's study dated January 17, 2010." +AirFoil w Dischrg Dampers FPLR,FanEIR-FPLR,Quadratic,,PLR,,0.227143,1.178929,-0.410714,,,,,,,,,,,,0.68,1,From .dat files included with MASControl2 +AirFoil w Inlet Vanes FPLR,FanEIR-FPLR,Quadratic,,PLR,,0.584345,-0.579167,0.970238,,,,,,,,,,,,0.48,1,From .dat files included with MASControl2 +Atmospheric-Blr-HIR-fPLR,FuelBoilers,Quadratic,,PLR,,0.02699999,1.10549998,-0.13249961,,,,,,,,,,,,,,From .dat files included with MASControl2 +Boiler Constant Efficiency Curve,Boiler,Cubic,FIRRatio,QRatio,,1,0,0,0,,,,,,,0,1,,,,,From DOE Reference Building +Boiler with Minimum Turndown,Boiler,Cubic,FIRRatio,QRatio,,0.7791,1.4745,-2.5795,1.3467,,,,,,,0,1.3,,,,,From Regression of Prototype Building EMS +Boiler with No Minimum Turndown,Boiler,Cubic,FIRRatio,QRatio,,0.7463,1.3196,-2.2154,1.1674,,,,,,,0,1.3,,,,,From Regression of Prototype Building EMS +BOILER-EFFFPLR-NECB2011,Boiler,Cubic,FIRRatio,QRatio,,0.2901,2.6664,-3.764,1.82,,,,,,,0,1,,,,,From NECB 2011 +CdTe_Spectral-fAirMass,PV-Module,Cubic,,AirMass,,0.93700588,0.05130703,-0.00646639,0.00017267,,,,,,,,,,,,,From .dat files included with MASControl2 +CentChlrAirCoolCap-fCHW&OAT,Chiller,BiQuadratic,QRatio,CHWT,OAT,0.94533053,0.068473818,-0.003361694,0.000108108,-0.000225,0.000082,,,,,,,,,,,From .dat files included with MASControl2 +CentChlrAirCoolEIR-fCHW&OAT,Chiller,BiQuadratic,EIRRatio,CHWT,OAT,0.47343824,0.015708042,-0.000948,0.012260718,0.0000955,-0.000352,,,,,,,,,,,From .dat files included with MASControl2 +CentChlrAirCoolEIR-fPLR,Chiller,Quadratic,EIRRatio,PLR,,0.24258,0.41468,0.34273973,,,,,,,,,,,,,,From .dat files included with MASControl2 +CentH2O-Cap-fCHWT&ECT,HermCentrifugal,BiQuadratic,QRatio,CHWT,ECT,0.36460761,-0.030523554,-0.001929776,0.066367926,-0.001891966,0.003110627,,,,,,,,,,,From .dat files included with MASControl2 +CentH2O-EIR-fCHWT&ECT,HermCentrifugal,BiQuadratic,EIRRatio,CHWT,ECT,0.65868459,-0.025336458,0.000991,0.01280322,0.000171,-0.000301,,,,,,,,,,,From .dat files included with MASControl2 +CentH2O-EIR-fPLR&dT,HermCentrifugal,BiQuadratic,EIRRatio,PLR,dT,0.27969646,0.57375735,0.25690463,-0.010452906,0.000475,-0.006354126,,,,,,,,,,,From .dat files included with MASControl2 +CentH2OVSD-Cap-fCHWT&ECT,HermCentrifugal,BiQuadratic,QRatio,CHWT,ECT,0.36211013,-0.032249754,-0.000886,0.066743838,-0.001731488,0.002180358,,,,,,,,,,,From .dat files included with MASControl2 +CentH2OVSD-EIR-fCHWT&ECT,HermCentrifugal,BiQuadratic,EIRRatio,CHWT,ECT,0.41386133,-0.088037676,0.00098,0.056770308,-0.000946,0.001418731,,,,,,,,,,,From .dat files included with MASControl2 +CentH2OVSD-EIR-fPLR&dT,HermCentrifugal,BiQuadratic,EIRRatio,PLR,dT,0.14703037,-0.00349667,1.01161313,-0.006474546,0.00088,-0.020960478,,,,,,,,,,,From .dat files included with MASControl2 +ChillerCentCapFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.7446451,0.0114858,0.0000148,0.022401,-0.000688,0.0009839,,,,,5,10,24,35,,,From Dick Lord's Chiller Model study for ASHRAE 2007 baseline +ChillerCentEIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.772877,0.022101,-0.0000799,-0.0070045,0.0004763,-0.0010612,,,,,5,10,24,35,,,From Dick Lord's Chiller Model study for ASHRAE 2007 baseline +ChillerCentEIRPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,From Dick Lord's Chiller Model study for ASHRAE 2007 baseline +ChlrAirRecipEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.114437,0.545933,0.342299,,,,,,,,0,1,,,0.11,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrAirRecipEIRRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.542784,-0.013907,0.000476,0.012197,0.000149,-0.000334,,,,,4.44,12.22,23.89,46.11,0.72,1.3,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrAirRecipQRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.12603,0.041571,0.000253,-0.010526,0.00001,-0.000256,,,,,4.44,12.22,23.89,46.11,0.82,1.3,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrAirScrewEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.036487,0.734743,0.219947,,,,,,,,0,1,,,0.04,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrAirScrewEIRRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.570624,0.011954,-0.000522,-0.000032,0.000421,-0.000606,,,,,4.44,12.22,23.89,46.11,0.7,1.38,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrAirScrewQRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.985959,0.049487,-0.000298,-0.003737,-0.000045,-0.000502,,,,,4.44,12.22,23.89,46.11,0.82,1.3,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrAirScrollEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.063691,0.584888,0.352803,,,,,,,,0,1,,,0.06,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrAirScrollEIRRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.702194,-0.004466,0.000535,-0.005506,0.000544,-0.000729,,,,,4.44,12.22,23.89,46.11,0.69,1.45,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrAirScrollQRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.02138,0.037021,0.000233,-0.003893,-0.000065,-0.000269,,,,,4.44,12.22,23.89,46.11,0.82,1.3,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrHPAirCoolCap-fCHW&OAT,Chiller,BiQuadratic,QRatio,CHWT,OAT,1.13076899,0.03157983,0.000358,-0.009856332,0.0000101,-0.00015,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPAirCoolEIR-fCHW&OAT,Chiller,BiQuadratic,EIRRatio,CHWT,OAT,0.5637406,-0.009225918,0.000353,0.009452178,0.000187,-0.000314,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPAirHeatCap-fHW&39-,Chiller,BiQuadratic,QRatio,HW,39,0.92141508,-0.003413682,-0.00000386,0.0324,0.000611,-0.0000518,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPAirHeatCap-fHW&39+,Chiller,BiQuadratic,QRatio,HW,39+,0.94069023,-0.004035888,0.000000421,0.046218906,-0.001703171,-0.000000227,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPAirHeatEIR-fHW&39-,Chiller,BiQuadratic,EIRRatio,HW,39,0.33398382,0.019817694,0.000012,0.0048024,-0.0000332,-0.000898,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPAirHeatEIR-fHW&39+,Chiller,BiQuadratic,EIRRatio,HW,39+,0.38886863,0.018107262,0.0000194,-0.026683668,0.002056655,-0.000499,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPH2OCoolCap_fCHW&ECT,Chiller/HP,BiQuadratic,QRatio,CHWT,ECT,35.68362061,0.62273101,-0.005677932,-0.248948775,-0.003461286,0.011142622,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPH2OCoolCap_fCHW&ECT-Old,Chiller/HP,BiQuadratic,QRatio,CHWT,ECT,0.96601399,0.04050054,0.000589,-0.008098668,0.0000665,-0.000454,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPH2OCoolEIR_fCHW&ECT,Chiller/HP,BiQuadratic,EIRRatio,CHWT,ECT,0.111287472,-0.002094557,0.000201,0.00170532,0.000168,-0.000308,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPH2OCoolEIR_fCHW&ECT-Old,Chiller/HP,BiQuadratic,EIRRatio,CHWT,ECT,0.61092869,-0.016352352,0.000407,0.003044232,0.000592,-0.000668,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPH2OHeatCap_fHWS&EET,Chiller/HP,BiQuadratic,QRatio,HWS,EET,29.914016,0.1544256,-0.0041472,0.6832512,-0.00203148,0.00199584,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPH2OHeatCap_fHWS&EET-Old,Chiller/HP,BiQuadratic,QRatio,HWS,EET,0.84649612,-0.00264807,0.0000231,0.02700126,0.00013,-0.000127,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPH2OHeatEIR_fHWS&EET,Chiller/HP,BiQuadratic,EIRRatio,HWS,EET,0.12004,-0.00011232,0.0000985,-0.00107928,0.0000732,-0.000134,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPH2OHeatEIR_fHWS&EET-Old,Chiller/HP,BiQuadratic,EIRRatio,HWS,EET,0.2068226,0.018812142,0.000105,-0.012659724,0.000406,-0.000399,,,,,,,,,,,From .dat files included with MASControl2 +ChlrWtrCentPathAAllEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.222149,0.503156,0.256905,,,,,,,,0.1,1,,,0.28,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrCentPathAAllEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.658643,-0.025339,0.000991,0.012801,0.000171,-0.000301,,,,,4.44,12.22,15.56,29.44,0.68,1.05,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrCentPathAAllQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.364691,-0.030521,-0.00193,0.066374,-0.001892,0.003111,,,,,4.44,12.22,15.56,29.44,0.87,0.91,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrCentPathBGtEql300Lt600tonEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.055483,0.451866,0.488242,,,,,,,,0.1,1,,,0.11,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrCentPathBGtEql300Lt600tonEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.756376,-0.015019,0.000156,0.00246,0.000515,-0.000687,,,,,4.44,12.22,15.56,29.44,0.63,1.12,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrCentPathBGtEql300Lt600tonQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,1.35608,0.04875,-0.000888,-0.014525,-0.000286,-0.00004,,,,,4.44,12.22,15.56,29.44,0.87,1.52,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrCentPathBGtEql600tonEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.107426,0.156775,0.739345,,,,,,,,0.1,1,,,0.13,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrCentPathBGtEql600tonEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.737625,0.001456,-0.000223,0.007116,0.000267,-0.000735,,,,,4.44,12.22,15.56,29.44,0.76,1.08,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrCentPathBGtEql600tonQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.854454,0.042526,-0.000185,0.011697,-0.000497,-0.000412,,,,,4.44,12.22,15.56,29.44,0.9,1.33,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrCentPathBLt300tonEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.208389,-0.121404,0.918455,,,,,,,,0.1,1,,,0.21,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrCentPathBLt300tonEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.711108,-0.023515,0.001194,0.017737,0.000152,-0.001159,,,,,4.44,12.22,15.56,29.44,0.69,1.13,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrCentPathBLt300tonQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,1.15508,0.036503,-0.000499,-0.001455,-0.000439,-0.000172,,,,,4.44,12.22,15.56,29.44,0.86,1.37,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.310965,0.322519,0.372745,,,,,,,,0.1,1,,,0.35,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.665307,-0.009339,0.000483,0.009492,0.000544,-0.000864,,,,,4.44,12.22,15.56,29.44,0.74,1.27,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.96744,0.037082,0.000434,-0.005837,-0.000049,-0.000274,,,,,4.44,12.22,15.56,29.44,0.89,1.33,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrPosDispPathBAllEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0,0.6206,0.3893,,,,,,,,0.1,1,,,0.07,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrPosDispPathBAllEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.428265,-0.024071,0.000849,0.016416,0.000381,-0.00059,,,,,4.44,12.22,15.56,29.44,0.5,1.07,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrPosDispPathBAllQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.899926,0.030102,-0.000332,-0.001743,-0.000092,0.000229,,,,,4.44,12.22,15.56,29.44,0.93,1.21,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CHW-Coil-Cap-fAirflow,CHWCoils,Quadratic,QRatio,Airflow,,0.0488,1.38,-0.425,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +CHW-Coil-Cap-fEWB&EWT,CHWCoils,BiQuadratic,QRatio,EWB,EWT,1.6726784,-0.13378464,0.0065124,0.03828096,0.0000826,-0.005868936,,,,,15.55556,29.44444,4.44444,18.33333,,,From .dat files included with MASControl2 +CHW-Coil-Cap-fFluidFlow,CHWCoils,Quadratic,QRatio,FluidFlow,,0.218,3199.5088,-3280000,,,,,,,,0,1,,,,,From .dat files included with MASControl2 +Coffin Defrost Curve,Refrigerated Case,Cubic,,,,0.3475,0.0296,0.0007,0.00003,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings +Coffin Latent Curve,Refrigerated Case,Cubic,,,,0.3379,0.0309,0.0005,0.00004,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings +COIL-BF-FFLOW-SPEC,CoilBF-FFLOW,Linear,,Flow,,0.33,1419.6496,,,,,,,,,,,,,0.8,,From .dat files included with MASControl2 +Coil-Bypass-Factor-fPLR,CHWCoils,Linear,QRatio,PLR,,1,0,,,,,,,,,,,,,,,From .dat files included with MASControl2 +CoilClgDXDblEIRRatio_fCFMRatio,DX Cooling Coil,Cubic,EIRRatio,FlowRatio,,1.007948,0.345441,-0.692289,0.338899,,,,,,,0,1,,,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgDXDblQRatio_fCFMRatio,DX Cooling Coil,Cubic,QRatio,FlowRatio,,0.472786,1.243342,-1.038706,0.322578,,,,,,,-100,100,0.47,,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgDXEIRRatio_fQFrac,DX Cooling Coil,Cubic,EIRRatio,QRatio,,0,5.1091,-8.5515,4.4744,,,,,,,0.7,1,0.92,1,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgDXEIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.116709,0.028458,-0.000411,0.021422,0.000162,-0.00068,,,,,13.89,25,23.89,46.11,0.77,1.33,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgDXQRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.86779,0.014245,0.000554,-0.007569,0.000032,-0.000191,,,,,13.89,25,23.89,46.11,0.77,1.29,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgDXSEER13EER11EIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,-0.199992,-0.035686,0.000787,0.074834,-0.000516,-0.000573,,,,,13.89,25,23.89,46.11,0.55,1.44,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgDXSEER15EER11EIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,-1.790474,-0.028777,0.000763,0.153391,-0.001482,-0.000721,,,,,13.89,25,23.89,46.11,0.35,1.42,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgDXSEER16EER13EIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.686684,-0.035826,0.000781,0.025564,0.000163,-0.000559,,,,,13.89,25,23.89,46.11,0.65,1.51,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgDXSEER17EER11EIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,-3.060538,-0.023207,0.000744,0.216093,-0.002253,-0.000839,,,,,13.89,25,23.89,46.11,0.2,1.4,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgDXSEER18EER13EIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,-1.247121,-0.027513,0.000752,0.121123,-0.001013,-0.000736,,,,,13.89,25,23.89,46.11,0.41,1.48,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgDXSEER20EER13EIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,-2.72492,-0.02112,0.00073,0.194128,-0.001911,-0.000872,,,,,13.89,25,23.89,46.11,0.23,1.45,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgDXSEEREIRRatio_fQFrac,DX Cooling Coil,Cubic,EIRRatio,QRatio,,1,0,0,0,,,,,,,0.7,1,1,1,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgDXSnglEIRRatio_fCFMRatio,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.156,-0.1816,0.0256,,,,,,,,0,1,,,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgDXSnglQRatio_fCFMRatio,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgPTACEIRRatio_fQFrac,DX Cooling Coil,Cubic,EIRRatio,QRatio,,0.85,0.15,0,0,,,,,,,0.7,1,0.96,1,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgPTACEIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.341434,0.03481,-0.000625,0.004941,0.000437,-0.000729,,,,,13.89,25,23.89,46.11,0.75,1.4,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgPTACQRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.942879,0.009538,0.000684,-0.011002,0.000006,-0.00001,,,,,13.89,25,23.89,46.11,0.71,1.34,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ConstantCubic,,Cubic,,,,1,0,0,0,,,,,,,-100,100,,,,,From Reference Buildings +Cool-PLF-fPLR,DX Cooling Coil,Quadratic,EIRRatio,QRatio,,0.90949556,0.09864773,-0.00819488,,,,,,,,0,1,,,,,From PNNL Prototype FullServiceRestaurant +CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.2055,-0.32953,0.12308,,,,,,,,0.75918,1.13877,,,,,"From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" +Curve_Biquadratic_CBES_01,,BiQuadratic,,,,0.86779,0.014245,0.000554,-0.007569,0.000032,-0.000191,,,,,0,100,0,100,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov +Curve_Biquadratic_CBES_02,,BiQuadratic,,,,-0.199992,-0.035686,0.000787,0.074834,-0.000516,-0.000573,,,,,13.9,25,23.9,43.3,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov +Curve_Biquadratic_CBES_03,,BiQuadratic,,,,0.9425878,0.00954335,0.00068377,-0.0110427,0.00000525,-0.00000972,,,,,17,22,13,46,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov +Curve_Biquadratic_CBES_04,,BiQuadratic,,,,0.3424144,0.03488501,-0.0006237,0.00497722,0.00043795,-0.000728,,,,,17,22,13,46,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov +Curve_Quadratic_CBES_01,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov +Curve_Quadratic_CBES_02,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.156,-0.1816,0.0256,,,,,,,,0.5,1.5,,,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov +Curve_Quadratic_CBES_03,,Quadratic,,,,1,0,0,,,,,,,,0,1,,,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov +Curve_Quadratic_CBES_04,,Quadratic,,,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov +Curve_Quadratic_CBES_05,,Quadratic,,,,1.1552,-0.1808,0.0256,,,,,,,,0.5,1.5,,,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov +Curve_Quadratic_CBES_06,,Quadratic,,,,0.85,0.15,0,,,,,,,,0,1,,,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov +DEER DHW HIR-FPLR Curve,DEERDHWHIR-FPLR,Linear,,PLR,,0,1,,,,,,,,,,,,,,,From .dat files included with MASControl2 +DEER_defrost,Refrigeration,Cubic,,,,0.023632,0.0006232,0.00002832,4.4035E-07,,,,,,,-23,7,,,,, +DEER_Heat_Rejections_LT,Refrigeration,Linear,Capacity,DeltaT,,0,16383.61446,,,,,,,,,-100,100,,,,,From eQuest Grocery store model +DEER_Heat_Rejections_MT,Refrigeration,Linear,Capacity,DeltaT,,0,20626.34211,,,,,,,,,-100,100,,,,,From eQuest Grocery store model +Default_Case_Latent_Cedit_Curve,Refrigeration,Cubic,,,,0.026526281,0.001078032,-6.02558E-05,1.23732E-06,,,,,,,-35,20,,,,, +Defrost-ResisDem-Frac-fOWB&ODB,DXCool/Heat,BiLinear,QRatio,OWB,ODB,0.0333,0,0,,,,,,,,-23.333,29.444,-23.333,29.444,,,From .dat files included with MASControl2 +Defrost-ResisTime-Frac-fOWB&ODB,DXCool/Heat,BiLinear,QRatio,OWB,ODB,0.0333,0,0,,,,,,,,-23.333,29.444,-23.333,29.444,,,From .dat files included with MASControl2 +Defrost-ReversDem-Frac-fOWB&ODB,DXCool/Heat,BiLinear,QRatio,OWB,ODB,0.0333,0,0,,,,,,,,-23.333,29.444,-23.333,29.444,,,From .dat files included with MASControl2 +Defrost-ReversTime-Frac-fOWB&ODB,DXCool/Heat,BiLinear,QRatio,OWB,ODB,0.0583,0,0,,,,,,,,-23.333,29.444,-23.333,29.444,,,From .dat files included with MASControl2 +Desc-Gas-fT&W,Desiccant,BiQuadratic,,T,W,18784.36736,-3209.524992,-11.8830564,3874.59,-1.69627,-23.53176,,,,,7.22222,46.11111,0,0.1,,,From .dat files included with MASControl2 +Desc-HR8-fWB1&WB6,Desiccant,BiQuadratic,,WB1,WB6,-0.27680768,0.071770464,0.000735,0.145668672,0.000591,-0.002648246,,,,,12.77778,46.11111,12.77778,46.11111,,,From .dat files included with MASControl2 +Desc-HR8PL-fWB1&WB6,Desiccant,BiQuadratic,,WB1,WB6,-0.05234208,0.076111488,0.000502,0.11464641,0.001235315,-0.002453879,,,,,12.77778,46.11111,12.77778,46.11111,,,From .dat files included with MASControl2 +Desc-kW-fT&W,Desiccant,BiQuadratic,,T,W,3.33024,-0.010674,0,0.00404,0,0,,,,,7.22222,46.11111,0,0.1,,,From .dat files included with MASControl2 +Desc-QREG-fWB1&WB6,Desiccant,BiQuadratic,,WB1,WB6,80.58068736,-0.627217344,0.0170748,-2.186211312,0.0000437,0.018960674,,,,,12.77778,40.55556,12.77778,46.11111,,,From .dat files included with MASControl2 +Desc-QREGPL-fWB1&WB6,Desiccant,BiQuadratic,,WB1,WB6,20.30901408,-0.159663744,0.0046008,-0.586622934,-0.00024,0.005206064,,,,,12.77778,46.11111,12.77778,46.11111,,,From .dat files included with MASControl2 +Desc-T-fT&W,Desiccant,BiQuadratic,,T,W,31.53328,1.0173168,-0.0033372,0.295,-0.00017,-0.0015696,,,,,7.22222,46.11111,0,0.1,,,From .dat files included with MASControl2 +Desc-T8-fWB1&WB6,Desiccant,BiLinear,,WB1,WB6,34.64,1.6236,0.2574,,,,,,,,12.77778,46.11111,12.77778,46.11111,,,From .dat files included with MASControl2 +Desc-T8PL-fWB1&WB6,Desiccant,BiLinear,,WB1,WB6,32.7692,1.7496,0.06588,,,,,,,,12.77778,46.11111,12.77778,46.11111,,,From .dat files included with MASControl2 +Desc-W-fT&W,Desiccant,BiQuadratic,,T,W,7.82704,0.119376,0.0144504,0.0831,0.000697,0.002862,,,,,7.22222,46.11111,0,0.1,,,From .dat files included with MASControl2 +Direct-Effectiveness-fFlow,EvapCooler,Quadratic,,Flow,,1.18,-546.67104,333000,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +DOE Ref DX Clg Coil Cool-CAP-fFlow,DX Cooling Coil,Cubic,QRatio,FlowRatio,,1,0,0,0,,,,,,,-100,100,,,,,From DOE Pre-1980 Reference Building +DOE Ref DX Clg Coil Cool-Cap-fT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.9712123,-0.015275502,0.001443452,-0.00039321,-6.8364E-06,-0.000290596,,,,,-100,100,-100,100,,,From DOE Pre-1980 Reference Building +DOE Ref DX Clg Coil Cool-EIR-fFlow,DX Cooling Coil,Cubic,EIRRatio,FlowRatio,,1,0,0,0,,,,,,,-100,100,,,,,From DOE Pre-1980 Reference Building +DOE Ref DX Clg Coil Cool-EIR-fT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.28687133,0.023902164,-0.000810648,0.013458546,0.000338936,-0.000487004,,,,,-100,100,-100,100,,,From DOE Pre-1980 Reference Building +DOE Ref DX Clg Coil Cool-PLF-fPLR,DX Cooling Coil,Quadratic,EIRRatio,QRatio,,0.90949556,0.09864773,-0.00819488,,,,,,,,0,1,,,,, +Draft-Fan-EIR-fPLR,FuelBoilers,Cubic,EIRRatio,PLR,,0.35071223,0.3080535,-0.5413736,0.87198823,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +DW-Elec-EIR-fPLR,ElecDW-Heater,Linear,EIRRatio,PLR,,0,1,,,,,,,,,,,,,,,From .dat files included with MASControl2 +DW-Gas-HIR-fPLR,GasDW-Heater,Quadratic,,PLR,,0.021826,0.97763,0.000543,,,,,,,,,,,,,,From .dat files included with MASControl2 +DW-Gas-Pilotless-HIR-fPLR,GasDW-Heater,Quadratic,,PLR,,0,0.999457,0.000543,,,,,,,,,,,,,,From .dat files included with MASControl2 +DW-HeatPump-Cap-fSupplyT&EDB,HeatPumpDW-Heat,BiQuadratic,QRatio,SupplyT,EDB,0.74922298,0,0,0.028130328,0.000236,0,,,,,,,,,,,From .dat files included with MASControl2 +DW-HeatPump-EIR-fPLR,HeatPumpDW-Heat,Cubic,EIRRatio,PLR,,0.08565215,0.93881371,-0.1834361,0.15897022,,,,,,,,,,,,,From .dat files included with MASControl2 +DW-HeatPump-EIR-fSupplyT&EDB,HeatPumpDW-Heat,BiQuadratic,EIRRatio,SupplyT,EDB,1.25311702,0,0,-0.033921486,0.000426,0,,,,,,,,,,,From .dat files included with MASControl2 +DX Coil Cap-FF,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,,"From PNNL Prototype Buildings ApartmentMidRise, HotelSmall, OfficeSmall, RetailStandAlone, RetailStripmall, SchoolPrimary, Warehouse" +DX-Bypass-Factor-fAirflow,DXCool/Heat,Quadratic,QRatio,Airflow,,-0.2542341,1.2182557,0.03597841,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +DX-Bypass-Factor-fEWB&EDB,DXCool/Heat,BiQuadratic,QRatio,EWB,EDB,0.8463094,0.014259096,0.000184,-0.014791716,-0.00000548,0.000487,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +DX-Bypass-Factor-fPLR,DXCool/Heat,Linear,QRatio,PLR,,1,0,,,,,,,,,,,,,,,From .dat files included with MASControl2 +DX-Cap-fAirflow,DXCool/Heat,Cubic,QRatio,Airflow,,0.06429396,1.99755645,-1.44277024,0.38091758,,,,,,,,,,,,,From .dat files included with MASControl2 +DX-Cool-Cap-fEWB&OAT,DXCool/Heat,BiQuadratic,QRatio,EWB,OAT,0.86791562,0.014247648,0.000554,-0.007558056,0.000033,-0.000192,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +DX-Cool-Cap-fRPM&OAT,DXCool/Heat,BiQuadratic,QRatio,RPM,OAT,32,9.549296596,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 +DX-Cool-CondFan-fPLR&OAT,DXCool/Heat,BiQuadratic,PwrRatio,PLR,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 +DX-Cool-CycleLoss-fPLR,DXCool/Heat,Linear,QRatio,PLR,,0.7,0.3,,,,,,,,,,,,,,,From .dat files included with MASControl2 +DX-Cool-EIR-fEWB&OAT,DXCool/Heat,BiQuadratic,EIRRatio,EWB,OAT,0.1210048,0.0285336,-0.000411,0.02134944,0.000161,-0.00068,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +DX-Cool-EIR-fPLR,DXCool/Heat,Cubic,EIRRatio,PLR,,0.201,-0.0312,1.95,-1.12,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +DX-Cool-EIR-fRPM&OAT,DXCool/Heat,BiQuadratic,EIRRatio,RPM,OAT,32,9.549296596,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 +DX-Cool-Waste-Heat-fEWB&OAT,DXCool/Heat,BiLinear,QRatio,EWB,OAT,1,0,0,,,,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +DX-Cool-Waste-Heat-fRPM&OAT,DXCool/Heat,BiQuadratic,QRatio,RPM,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 +DX-Heat-Cap-fEDB&OAT,DXCool/Heat,BiQuadratic,QRatio,EDB,OAT,0.7422592,0,0,0.030682602,0.0000323,0,,,,,12.77778,29.44444,-12.22222,29.44444,,,From .dat files included with MASControl2 +DX-Heat-Cap-fRPM&OAT,DXCool/Heat,BiQuadratic,QRatio,RPM,OAT,32,9.549296596,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 +DX-Heat-CondFan-fPLR&OAT,DXCool/Heat,BiQuadratic,PwrRatio,PLR,OAT,1,0,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 +DX-Heat-CycleLoss-fPLR,DXCool/Heat,Linear,QRatio,PLR,,0.75,0.25,,,,,,,,,,,,,,,From .dat files included with MASControl2 +DX-Heat-EIR-fEDB&OAT,DXCool/Heat,BiQuadratic,EIRRatio,EDB,OAT,1.25399584,0,0,-0.040063338,0.0010877,0,,,,,12.77778,29.44444,-12.22222,29.44444,,,From .dat files included with MASControl2 +DX-Heat-EIR-fPLR,DXCool/Heat,Cubic,EIRRatio,PLR,,0.0857,0.939,-0.183,0.159,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +DX-Heat-EIR-fRPM&OAT,DXCool/Heat,BiQuadratic,EIRRatio,RPM,OAT,32,9.549296596,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 +DX-Heat-Waste-Heat-fEDB&OAT,DXCool/Heat,BiLinear,QRatio,EDB,OAT,1,0,0,,,,,,,,12.77778,29.44444,-12.22222,29.44444,,,From .dat files included with MASControl2 +DX-Heat-Waste-Heat-fRPM&OAT,DXCool/Heat,BiQuadratic,QRatio,RPM,OAT,1,0,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 +DX-Sens-Cap-fAirflow,DXCool/Heat,Cubic,QRatio,Airflow,,0.34465606,0.89289891,-0.3554498,0.1178948,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +DX-Sens-Cap-fEWB&OAT,DXCool/Heat,BiQuadratic,QRatio,EWB,OAT,2.93224448,-0.09445968,0.0002,-0.007176816,0.0000103,0.000109,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +DXCOOL-NECB2011-REF-CAPFFLOW,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,1,0,0,,,,,,,,0,1,,,,,From NECB 2011 +DXCOOL-NECB2011-REF-CAPFT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.867905,0.0142459,0.00055436,-0.0075575,0.000033,-0.0001918,,,,,13,24,24,46,,,From NECB 2011 +DXCOOL-NECB2011-REF-COOLEIRFFLOW,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1,0,0,,,,,,,,0,1,,,,,From NECB 2011 +DXCOOL-NECB2011-REF-COOLEIRFT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.116936,0.0284933,-0.0004112,0.0214108,0.00016103,-0.0006791,,,,,13,24,24,46,,,From NECB 2011 +DXCOOL-NECB2011-REF-COOLPLFFPLR,DX Cooling Coil,Cubic,EIRRatio,QRatio,,0.0277,4.9151,-8.184,4.2702,,,,,,,0.7,1,,,,,"From NECB, curve modified to take into account how PLF is used in E+, and PLF ranges (> 0.7)" +DXHEAT-NECB2011-REF-CAPFFLOW,DX Heating Coil,Cubic,QRatio,FlowRatio,,0.84,0.16,0,0,,,,,,,0.5,1.5,,,,,From NECB 2011 +DXHEAT-NECB2011-REF-CAPFT,DX Heating Coil,Cubic,QRatio,Toadb,,0.729,0.0319,0.000136,-0.00000875,,,,,,,-20,20,,,,,From NECB 2011 +DXHEAT-NECB2011-REF-EIRFFLOW,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.3824,-0.4336,0.0512,,,,,,,,0,1,,,,,From NECB 2011 +DXHEAT-NECB2011-REF-EIRFT,DX Heating Coil,Cubic,EIRRatio,Toadb,,1.2183,-0.03612,0.00142,-0.0000268,,,,,,,-20,20,,,,,From NECB 2011 +DXHEAT-NECB2011-REF-PLFFPLR,DX Heating Coil,Cubic,EIRRatio,QRatio,,0.3696,2.3362,-2.9577,1.2596,,,,,,,0.7,1,,,,,From NECB 2011 +Minisplit-Heat-Cap-fT,DX Heating Coil,BiQuadratic,QRatio,Tiadb,Toadb,1.14715889,-0.010386676,0,0.008653846,0,0,,,,,-100,100,-100,100,,,From OpenStudio-HPXML +Minisplit-Heat-Cap-fFF,DX Heating Coil,Quadratic,QRatio,Tiadb,Toadb,1,0,0,,,,,,,,0,2,0,2,,,From OpenStudio-HPXML +Minisplit-Heat-EIR-fT,DX Heating Coil,BiQuadratic,EIRRatio,Tiadb,Toadb,0.99999417,0.004684594,5.90129E-05,-0.002862447,1.30411E-05,-0.000161729,,,,,-100,100,-100,100,,,From OpenStudio-HPXML +Minisplit-Heat-EIR-fFF,DX Heating Coil,Quadratic,EIRRatio,Tiadb,Toadb,1,0,0,,,,,,,,0,2,0,2,,,From OpenStudio-HPXML +Minisplit-Heat-PLF-fPLR,DX Heating Coil,BiQuadratic,EIRRatio,Tiadb,Toadb,0.89,0.11,,,,,,,,,0,1,0.6,1,,,From OpenStudio-HPXML +Minisplit-Cool-Cap-fT,DX Cooling Coil,BiQuadratic,QRatio,Tiadb,Toadb,0.75319835,0.003618194,0,0.006574385,-6.87181E-05,0,,,,,0,100,0,100,,,From OpenStudio-HPXML +Minisplit-Cool-Cap-fFF,DX Cooling Coil,Quadratic,QRatio,Tiadb,Toadb,1,0,0,,,,,,,,0,2,0,2,,,From OpenStudio-HPXML +Minisplit-Cool-EIR-fT,DX Cooling Coil,BiQuadratic,EIRRatio,Tiadb,Toadb,-0.063769248,-0.001336059,1.41306E-05,0.019433076,-4.91396E-05,-4.90934E-05,,,,,0,100,0,100,,,From OpenStudio-HPXML +Minisplit-Cool-EIR-fFF,DX Cooling Coil,Quadratic,EIRRatio,Tiadb,Toadb,1,0,0,,,,,,,,0,2,0,2,,,From OpenStudio-HPXML +Minisplit-Cool-PLF-fPLR,DX Cooling Coil,BiQuadratic,EIRRatio,Tiadb,Toadb,0.89,0.11,,,,,,,,,0,1,0.6,1,,,From OpenStudio-HPXML +EFG-Si_Spectral-fAirMass,PV-Module,Cubic,,AirMass,,0.93235892,0.05557786,-0.00723784,0.00016577,,,,,,,,,,,,,From .dat files included with MASControl2 +Elec-HW-Blr-EIR-fPLR,ElecBoilers,Linear,EIRRatio,PLR,,0.02,0.98,,,,,,,,,,,,,,,From .dat files included with MASControl2 +Elec-Stm-Blr-EIR-fPLR,ElecBoilers,Linear,EIRRatio,PLR,,0.03,0.97,,,,,,,,,,,,,,,From .dat files included with MASControl2 +Engine-Chlr-Cap-fCHWT&ECT,EngineChiller,BiQuadratic,QRatio,CHWT,ECT,1.02245976,0.033624396,0,-0.00837585,0,0,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Engine-Chlr-HeatRej-fECT,EngineChiller,Cubic,,ECT,,0.81658293,0.00622926,0,0,,,,,,,60,150,,,,,From .dat files included with MASControl2 +Engine-Chlr-HeatRej-fPLR,EngineChiller,Cubic,,PLR,,1.05269921,-0.05269912,0,0,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Engine-Chlr-HIR-fCHWT&ECT,EngineChiller,BiQuadratic,,CHWT,ECT,0.76855672,-0.016619742,0.001163452,0.007451082,0.000302,-0.000971,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Engine-Chlr-HIR-fPLR,EngineChiller,Quadratic,,PLR,,0.12571636,0.34714213,0.52714163,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Engine-Exh-fPLR,EngineGenerator,Quadratic,,PLR,,0.024516,0.3323871,0.6430968,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Engine-HIR-fPLR,EngineGenerator,Linear,,PLR,,0.107,0.893,,,,,,,,,,,,,,,From .dat files included with MASControl2 +Engine-Jac-fPLR,EngineGenerator,Quadratic,,PLR,,0.287936,1.0204516,-0.3083871,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +FluidCooler-FluidCap-fApp&WB,FluidCooler,BiQuadratic,QRatio,App,WB,-0.16463568,0.048677022,-0.001437296,0.072275256,0.000924,0.005085439,,,,,,,,,,,From .dat files included with MASControl2 +FluidCooler-FluidCap-fRng&WB,FluidCooler,BiQuadratic,QRatio,Rng,WB,0,0.18,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 +ForcedDraft-Blr-HIR-fPLR,FuelBoilers,Quadratic,,PLR,,0.01599992,0.94495332,0.03904687,,,,,,,,,,,,,,From .dat files included with MASControl2 +ForCurve w Dischrg Dampers FPLR,FanEIR-FPLR,Quadratic,,PLR,,0.190667,0.31,0.5,,,,,,,,,,,,0.22,1,From .dat files included with MASControl2 +ForCurve w Inlet Vanes FPLR,FanEIR-FPLR,Quadratic,,PLR,,0.339619,-0.848139,1.495671,,,,,,,,,,,,0.22,1,From .dat files included with MASControl2 +FURNACE_PACU_VAV_CoolCCarrier48TM014_12tons_EIRFFF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.19525,-0.306138,0.110973,,,,,,,,0.75,1.25,,,,,From PNNL OfficeMedium +FURNACE_PACU_VAV_CoolCCarrier48TM014_12tons_EIRFT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,-0.536161,0.105138,-0.00172659,0.0149848,0.000659948,-0.0017385,,,,,16.5556,22.1111,23.7778,47.66,,,From PNNL Prototype Buildings OfficeMedium +FURNACE-EFFPLR-NECB2011,Gas Heating Coil,Cubic,FIRRatio,QRatio,,0.7277,1.0667,-1.5174,0.7282,,,,,,,0,1,,,,,From NECB 2011 +Furnace-HIR-fPLR,Furnace,Quadratic,FIRRatio,PLR,,0.0186,1.09,-0.113,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Gas-Absor-Cap-fCHWT&ECT,Chiller/Heater,BiQuadratic,QRatio,CHWT,ECT,0.362073,0.0001386,0.001458,0.0733878,-0.00206064,0.00101,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Gas-Absor-HCap-fCoolPLR,Chiller/Heater,Quadratic,QRatio,CoolPLR,,0.863599,-1.30495346,0.44135284,,,,,,,,,,,,,,From .dat files included with MASControl2 +Gas-Absor-HIR-fCHWT&ECT,Chiller/Heater,BiQuadratic,,CHWT,ECT,0.96182051,-0.0507105,0.003155468,0.005732838,0.000349,-0.00118516,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Gas-Absor-HIR-fDesiccantT,Chiller/Heater,Cubic,,DesiccantT,,0.85427336,0.002997504,0.0000426,0,,,,,,,100,300,,,,,From .dat files included with MASControl2 +Gas-Absor-Qreg-fDesiccantT,Chiller/Heater,Cubic,,DesiccantT,,0.5984,-0.00234,0,0,,,,,,,100,300,,,,,From .dat files included with MASControl2 +GasTurbine-Cap-fPLR,GasTurbineGen,Linear,QRatio,PLR,,1.24,-0.0041,,,,,,,,,,,,,,,From .dat files included with MASControl2 +GasTurbine-Exh-fPLR,GasTurbineGen,Quadratic,,PLR,,0.295626,0.4930194,0.2113548,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +GasTurbine-HIR-fPLR,GasTurbineGen,Quadratic,,PLR,,0.442979,0.3974,0.1569621,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +GHP-Bypass-Factor-fAirflow,GasHeat-Pump,Quadratic,QRatio,Airflow,,-0.254,1.22,0.036,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +GHP-Bypass-Factor-fEWB&EDB,GasHeat-Pump,BiQuadratic,QRatio,EWB,EDB,0.85028352,0.014256792,0.000184,-0.014791716,-0.00000548,0.000487,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +GHP-Bypass-Factor-fPLR,GasHeat-Pump,Linear,QRatio,PLR,,1,0,,,,,,,,,,,,,,,From .dat files included with MASControl2 +GHP-Cool-Cap-fEWB&OAT,GasHeat-Pump,BiLinear,QRatio,EWB,OAT,1.1688,0.01926,-0.01539,,,,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +GHP-Cool-Cap-fRPM&OAT,GasHeat-Pump,BiQuadratic,QRatio,RPM,OAT,-372.736,-234.129654,-36.65800433,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 +GHP-Cool-CondFan-fPLR&OAT,GasHeat-Pump,BiQuadratic,,PLR,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 +GHP-Cool-CycleLoss-fPLR,GasHeat-Pump,Linear,QRatio,PLR,,0.82,0.18,,,,,,,,,,,,,,,From .dat files included with MASControl2 +GHP-Cool-HIR-fEWB&OAT,GasHeat-Pump,BiQuadratic,,EWB,OAT,1.1386752,-0.049248,0.000914,0.02128896,0.000306,-0.000953,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +GHP-Cool-HIR-fRPM&OAT,GasHeat-Pump,BiQuadratic,,RPM,OAT,-369.60598,-234.0532596,-36.93157152,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 +GHP-Cool-Waste-Heat-fEWB&OAT,GasHeat-Pump,BiLinear,QRatio,EWB,OAT,1,0,0,,,,,,,,,,,,,,From .dat files included with MASControl2 +GHP-Cool-Waste-Heat-fRPM&OAT,GasHeat-Pump,BiQuadratic,QRatio,RPM,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 +GHP-Defrost-Frac-fOWB&ODB,GasHeat-Pump,BiLinear,QRatio,OWB,ODB,0.0333,0,0,,,,,,,,-23.33333,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 +GHP-Heat-Cap-fEDB&OAT,GasHeat-Pump,BiQuadratic,QRatio,EDB,OAT,0.8291632,0,0,0.01817136,0.000281,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 +GHP-Heat-Cap-fRPM&OAT,GasHeat-Pump,BiQuadratic,QRatio,RPM,OAT,157.86,89.17133162,12.58409104,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 +GHP-Heat-CondFan-fPLR&OAT,GasHeat-Pump,BiQuadratic,,PLR,OAT,1,0,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 +GHP-Heat-CycleLoss-fPLR,GasHeat-Pump,Linear,QRatio,PLR,,0.82,0.18,,,,,,,,,,,,,,,From .dat files included with MASControl2 +GHP-Heat-HIR-fEDB&OAT,GasHeat-Pump,BiQuadratic,,EDB,OAT,1.14897728,0,0,-0.017395056,-0.000026,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 +GHP-Heat-HIR-fRPM&OAT,GasHeat-Pump,BiQuadratic,,RPM,OAT,194.037,109.788263,15.50214113,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 +GHP-Heat-Waste-Heat-fEDB&OAT,GasHeat-Pump,BiLinear,QRatio,EDB,OAT,1,0,0,,,,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 +GHP-Heat-Waste-Heat-fRPM&OAT,GasHeat-Pump,BiQuadratic,QRatio,RPM,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 +GHP-Sens-Cap-fEWB&OAT,GasHeat-Pump,BiQuadratic,QRatio,EWB,OAT,1.49637568,0.079056576,-0.004212,-0.030189312,0.000157,0.00062,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +Glass Door Defrost Curve,Refrigerated Case,Cubic,,,,0.3475,0.0296,0.0007,0.00003,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings +Glass Door Latent Curve,Refrigerated Case,Cubic,,,,0.3379,0.0309,0.0005,0.00004,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings +GoodCyclingAC-EIR-fPLR,CyclingAC,Cubic,EIRRatio,PLR,,0.00000273,1.05259,-0.0552087,0.00262236,,,,,,,,,,,,,From .dat files included with MASControl2 +GSHP/WLHP_BF_fAirflow-Old,GSHP/WLHPCurves,Cubic,QRatio,Airflow,,-0.828,14.3,-21.9,9.4,,,,,,,,,,,,,From .dat files included with MASControl2 +GSHP/WLHP_BF_fEwbEwt,GSHP/WLHPCurves,BiLinear,QRatio,EWB,EWT,-0.2016,0.0297,0.02646,,,,,,,,,,,,0.347365,1.67341,From .dat files included with MASControl2 +GSHP/WLHP_BF_fEwbEwt-Old,GSHP/WLHPCurves,BiQuadratic,QRatio,EWB,EWT,-5.522656,0.735768,-0.0185004,0.1418832,0.000943,-0.010206,,,,,,,,,,,From .dat files included with MASControl2 +GSHP/WLHP_Cool_Cap_fEwbEwt,GSHP/WLHPCurves,BiLinear,QRatio,EWB,EWT,0.88114368,0.015264,-0.007493418,,,,,,,,,,,,0.803411,1.18555,From .dat files included with MASControl2 +GSHP/WLHP_Cool_EIR_fEwbEwt,GSHP/WLHPCurves,BiLinear,EIRRatio,EWB,EWT,0.4111216,-0.00396,0.03011184,,,,,,,,,,,,0.300674,1.80627,From .dat files included with MASControl2 +GSHP/WLHP_H/C_EIR-fPLR,GSHP/WLHPCurves,Quadratic,EIRRatio,PLR,,0.0414,0.328,0.575337,,,,,,,,,,,,0,1,From .dat files included with MASControl2 +GSHP/WLHP_H/C_EIR-fPLR-Old,GSHP/WLHPCurves,Cubic,EIRRatio,PLR,,0.00988,1.08,-0.105,0.0151,,,,,,,,,,,,,From .dat files included with MASControl2 +GSHP/WLHP_Heat_Cap_fEdbEwt,GSHP/WLHPCurves,BiLinear,QRatio,EDB,EWT,1.07264,-0.003564,0.027,,,,,,,,,,,,0.966284,1.86368,From .dat files included with MASControl2 +GSHP/WLHP_Heat_EIR_fEdbEwt,GSHP/WLHPCurves,BiLinear,EIRRatio,EDB,EWT,0.59444,0.01908,-0.009774,,,,,,,,,,,,0.681922,1.10294,From .dat files included with MASControl2 +HeatSys1 Boiler Non-Condensing Boiler Curve,Boiler,Cubic,FIRRatio,QRatio,,0.626428326,0.645643582,-0.77720685,0.313806701,,,,,,,0.1,1,,,,,From Prototype Buildings +HeatWheel-EIR-fSpeed,ERVUnit,Linear,EIRRatio,Speed,,25.8,7.639437277,,,,,,,,,,,,,,,From .dat files included with MASControl2 +Herm-Cent-Cap-fCHWT&ECT,HermCentrifugal,BiQuadratic,QRatio,CHWT,ECT,0.257896,0.0389016,-0.000217,0.0468684,-0.000943,-0.000343,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Herm-Cent-EIR-fCHWT&ECT,HermCentrifugal,BiQuadratic,EIRRatio,CHWT,ECT,0.933884,-0.058212,0.00450036,0.00243,0.000486,-0.001215,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Herm-Cent-EIR-fPLR,HermCentrifugal,Quadratic,EIRRatio,PLR,,0.222903,0.313387,0.46371,,,,,,,,0,0.105,,,,,From .dat files included with MASControl2 +Herm-Rec-Cap-fCHWT&ECT,HermReciprocatg,BiQuadratic,QRatio,CHWT,ECT,0.507883,0.1452276,-0.00625644,-0.0011178,-0.00013,-0.000282,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Herm-Rec-EIR-fCHWT&ECT,HermReciprocatg,BiQuadratic,EIRRatio,CHWT,ECT,1.030757,-0.103536,0.00710208,0.0093186,0.000318,-0.00104,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Herm-Rec-EIR-fPLR,HermReciprocatg,Quadratic,EIRRatio,PLR,,0.088065,1.137742,-0.225806,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Hospital Kitchen_Flr_5_Case:1_WALKINFREEZERSingleShelfHorizontal_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.0236,0.0006,0,0,,,,,,,-35,20,,,,,From Prototype Buildings +Hospital Kitchen_Flr_5_Case:2_SELFCONTAINEDDISPLAYCASEMultiShelfVertical_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,6.02558E-05,1.23732E-06,,,,,,,-35,20,,,,,From Prototype Buildings +HotelLarge Kitchen_Flr_6_Case:1_WALKINFREEZERSingleShelfHorizontal_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.0236,0.0006,0,0,,,,,,,-35,20,,,,,From Prototype Buildings +HotelLarge Kitchen_Flr_6_Case:2_SELFCONTAINEDDISPLAYCASEMultiShelfVertical_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,6.02558E-05,1.23732E-06,,,,,,,-35,20,,,,,From Prototype Buildings +HP-Bypass-Factor-fAirflow,Water-LoopHP,Cubic,QRatio,Airflow,,-0.828,14.3,-21.9,9.4,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +HP-Bypass-Factor-fEWB&EWT,Water-LoopHP,BiQuadratic,QRatio,EWB,EWT,-5.522656,0.735768,-0.0185004,0.1418832,0.000943,-0.010206,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +HP-Cool-Cap-fEWB&EWT,Water-LoopHP,BiQuadratic,QRatio,EWB,EWT,0.38053696,0.041974272,-0.0000309,-0.006642864,0.0000228,-0.0000881,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +HP-Cool-EIR-fEWB&EWT,Water-LoopHP,BiQuadratic,EIRRatio,EWB,EWT,1.3257696,-0.0504504,0.000988,0.02036448,0.0000791,-0.000531,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +HP-Cool-EIR-fPLR,Water-LoopHP,Linear,EIRRatio,PLR,,0.125,0.875,,,,,,,,,,,,,,,From .dat files included with MASControl2 +HP-Heat-Cap-fEDB&EWT,Water-LoopHP,BiLinear,QRatio,EDB,EWT,0.72324,-0.012204,0.02538,,,,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +HP-Heat-EIR-fEDB&EWT,Water-LoopHP,BiLinear,EIRRatio,EDB,EWT,1.2124,0.01089,-0.02088,,,,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +HP-Heat-EIR-fPLR,Water-LoopHP,Cubic,EIRRatio,PLR,,0.0857,0.939,-0.183,0.15897022,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +HP-Sens-Cap-fAirflow,Water-LoopHP,Cubic,QRatio,Airflow,,-0.13,2.16,-1.6,0.573,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +HP-Sens-Cap-fEWB&EWT,Water-LoopHP,BiQuadratic,QRatio,EWB,EWT,1.68318464,0.012410496,-0.00215784,-0.009251064,0.0000632,0.000174,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +HPACCoolCapFFF,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,, +HPACCoolCapFT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.766956,0.0107756,-4.14703E-05,0.00134961,-0.000261144,0.000457488,,,,,12.77778,23.88889,21.11111,46.11111,,, +HPACCOOLEIRFFF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.156,-0.1816,0.0256,,,,,,,,0.5,1.5,,,,, +HPACCOOLEIRFT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.297145,0.0430933,-0.000748766,0.00597727,0.000482112,-0.000956448,,,,,12.77778,23.88889,21.11111,46.11111,,, +HPACCOOLPLFFPLR,DX Cooling Coil,Quadratic,EIRRatio,QRatio,,0.85,0.15,0,,,,,,,,0,1,,,,, +HPACHeatCapFFF,DX Heating Coil,Cubic,QRatio,FlowRatio,,0.84,0.16,0,0,,,,,,,0.5,1.5,,,,,From Prototype Buildings +HPACHeatCapFT,DX Heating Coil,Cubic,QRatio,Toadb,,0.758746,0.027626,0.000148716,3.4992E-06,,,,,,,-20,20,,,,,From Prototype Buildings +HPACHeatEIRFFF,DX Heating Coil,Quadratic,EIRRatio,FlowRatio,,1.3824,-0.4336,0.0512,,,,,,,,0,1,,,,,From Prototype Buildings +HPACHeatEIRFT,DX Heating Coil,Cubic,EIRRatio,Toadb,,1.19248,-0.0300438,0.00103745,-0.000023328,,,,,,,-20,20,,,,,From Prototype Buildings +Htrec-Chlr-Cap-fCHWT&ECT,ElecHeatRecover,BiQuadratic,QRatio,CHWT,ECT,0.257896,0.0389016,-0.000217,0.0468684,-0.000943,-0.000343,,,,,4.44444,18.33333,12.77778,51.66667,,,From .dat files included with MASControl2 +Htrec-Chlr-EIR-fCHWT&ECT,ElecHeatRecover,BiQuadratic,EIRRatio,CHWT,ECT,0.933884,-0.058212,0.00450036,0.00243,0.000486,-0.001215,,,,,4.44444,18.33333,12.77778,51.66667,,,From .dat files included with MASControl2 +Htrec-Chlr-EIR-fPLR,ElecHeatRecover,Quadratic,EIRRatio,PLR,,0.349032,0.263871,0.387097,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Htrej-Fan-Pwr-fDamper,FluidCooler,Cubic,,Damper,,0.37607971,-0.21440694,1.00540793,-0.16712119,,,,,,,,,,,0.36,1,From .dat files included with MASControl2 +HW-Coil-Cap-fAirflow,HWCoils,Quadratic,QRatio,Airflow,,0.289,1.03,-0.317,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +HW-Coil-Cap-fdT,HWCoils,Quadratic,QRatio,dT,,-0.00467,1.8,0.010960272,,,,,,,,0,150,,,0.01,,From .dat files included with MASControl2 +HW-Coil-Cap-fFluidFlow,HWCoils,Quadratic,QRatio,FluidFlow,,0.18,2945.2432,-2540000,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Indirect-Effectiveness-fFlow,EvapCooler,Quadratic,,Flow,,1.1,-350,306000,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Inverter_EIR-fPLR,PV-Inverter,Quadratic,EIRRatio,PLR,,0.01677774,1.03766656,-0.05444431,,,,,,,,,,,,,,From .dat files included with MASControl2 +Large-CHW-Bypass-fAirflow,CHWCoils,Quadratic,QRatio,Airflow,,0.397,0.15,0.45374713,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Large-CHW-Coil-Bypass-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,0.435936,0.23652,-0.0047628,-0.1330272,0.00119556,0.000859,,,,,15.55556,29.44444,12.77778,29.44444,,,From .dat files included with MASControl2 +Large-CHW-Coil-Cap-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,0.09793216,-0.13886496,0.0124416,0.088907328,0.001938946,-0.009305604,,,,,15.55556,29.44444,12.77778,29.44444,,,From .dat files included with MASControl2 +Large-CHW-Sens-Cap-fAirflow,CHWCoils,Quadratic,QRatio,Airflow,,0.202,0.855,-0.057,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Large-CHW-Sens-Cap-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,0.12076864,-0.124558848,0.0063828,0.11146032,0.001847902,-0.006508285,,,,,15.55556,13.33333,12.77778,29.44444,,,From .dat files included with MASControl2 +Lp2Lp_Cap_fCHW&HWR,Loop2Loop,BiQuadratic,QRatio,CHWT,HWR,0.95122179,0.035393436,0.00027,-0.002654118,-0.0000869,-0.000274,,,,,,,,,,,From .dat files included with MASControl2 +Lp2Lp_EIR_fCHW&HWR,Loop2Loop,BiQuadratic,EIRRatio,CHWT,HWR,0.59918703,-0.00950724,0.000335,0.00863883,0.000312,-0.000386,,,,,,,,,,,From .dat files included with MASControl2 +Lp2Lp-EIR-fPLR-1Comp/Ckt,Loop2Loop,Quadratic,EIRRatio,PLR,,0.03481113,0.95945376,0.00573495,,,,,,,,,,,,,,From .dat files included with MASControl2 +Lp2Lp-EIR-fPLR-2Comp/Ckt,Loop2Loop,Quadratic,EIRRatio,PLR,,0.02297712,0.90150452,0.07551826,,,,,,,,,,,,,,From .dat files included with MASControl2 +LT_compressor_capacity,Refrigeration,BiCubic,Capacity,Suction T,Discharge T,170751.834,6102.9037,78.2619862,-2959.4326,19.7876589,-90.958101,0.43596477,-0.0411577,-0.608846,0.459133262,-40,17.8,4.4,54.4,,,From AEDG +LT_compressor_power,Refrigeration,BiCubic,Power,Suction T,Discharge T,29669.2711,1027.63205,18.1066262,-442.19971,11.1335288,-20.380452,0.13998065,-0.0588669,-0.2184515,0.203858467,-40,-17.8,4.4,54.4,,,From AEDG +mc-Si_Spectral-fAirMass,PV-Module,Cubic,,AirMass,,0.96113414,0.02820018,-0.00134585,-0.00012036,,,,,,,,,,,,,From .dat files included with MASControl2 +Measured_CoolCStandard10Ton_EIRFFF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.192,-0.1917,0,,,,,,,,0.776,1.197,,,,,From PNNL Prototype FullServiceRestaurant +MNECB-CAP-FAPP&WB,CAP-FAPP&WB,BiQuadratic,QRatio,App,WB,-0.05425558,-0.063981648,0.026052289,0.260016714,0.000809093,0.015903767,,,,,,,,,,,From .dat files included with MASControl2 +MNECB-CAP-FRNG&WB,CAP-FRNG&WB,BiQuadratic,QRatio,Rng,WB,188.8588489,0.300231774,-0.045692003,35.40844622,0.601350934,0.78576062,,,,,,,,,,,From .dat files included with MASControl2 +MNECB-Centrif-CAP-FT,Centrif-CAP-FT,BiQuadratic,QRatio,T,T,0.70790824,-0.002006568,-0.00259605,0.030058776,-0.001056434,0.002045704,,,,,,,,,,,From .dat files included with MASControl2 +MNECB-Centrif-EIR-FPLR,Centrif-EIR-FPLR,Quadratic,EIRRatio,PLR,,0.17149273,0.58820208,0.23737257,,,,,,,,,,,,,,From .dat files included with MASControl2 +MNECB-Centrif-EIR-FT,Centrif-EIR-FT,BiQuadratic,EIRRatio,T,T,0.5605438,-0.01377927,0.0000657,0.013219362,0.000268596,-0.000501131,,,,,,,,,,,From .dat files included with MASControl2 +MNECB-DW-HIR-fPLR,DHW-HIR,Quadratic,,PLR,,0.021826,0.97763,0.000543,,,,,,,,,,,,,,From .dat files included with MASControl2 +MNECB-HW-HIR-fPLR,HW-HIR,Quadratic,,PLR,,0.082597,0.996764,-0.079361,,,,,,,,,,,,,,From .dat files included with MASControl2 +MNECB-Recip-CAP-FT,Recip-CAP-FT,BiQuadratic,QRatio,T,T,1.0303123,0.033469794,0.00023639,-0.007295868,-0.0000232,-0.000148943,,,,,,,,,,,From .dat files included with MASControl2 +MNECB-Recip-EIR-FPLR,Recip-EIR-FPLR,Quadratic,EIRRatio,PLR,,0.08144133,0.41927141,0.49939604,,,,,,,,,,,,,,From .dat files included with MASControl2 +MNECB-Recip-EIR-FT,Recip-EIR-FT,BiQuadratic,EIRRatio,T,T,0.49969897,-0.013084056,0.000266425,0.016592526,0.000185393,-0.000375646,,,,,,,,,,,From .dat files included with MASControl2 +Multi Shelf Vertical Latent Energy Multiplier,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,-6.02558E-05,1.23732E-06,,,,,,,-35,20,,,,,From Reference Buildings +Multi Zone VAV with Airfoil or Backward Incline riding the curve,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.1631,1.5901,-0.8817,0.1281,,,,,,,0,1,,,0.7,,From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method +Multi Zone VAV with Airfoil or Backward Incline with inlet vanes,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.9977,-0.659,0.9547,-0.2936,,,,,,,0,1,,,0.5,,From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method +Multi Zone VAV with Forward Curved fans riding the curve,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.1224,0.612,0.5983,-0.3334,,,,,,,0,1,,,0.3,,From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method +Multi Zone VAV with Forward Curved with inlet vanes,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.3038,-0.7608,2.2729,-0.8169,,,,,,,0,1,,,0.3,,From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method +Multi zone VAV with static pressure reset,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.040759894,0.08804497,-0.07292612,0.943739823,,,,,,,0,1,,,0.1,,"OpenStudio default, baseline for System Types 5-8 from ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method" +Multi Zone VAV with vane-axial with variable pitch blades,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.1639,-0.4016,1.9909,-0.7541,,,,,,,0,1,,,0.2,,From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method +Multi Zone VAV with VSD and fixed SP setpoint,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.0013,0.147,0.9506,-0.0998,,,,,,,0,1,,,0.2,,Appendix G baseline from ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method +New_Low_Temp_Comp_Cap_Curve,,BiCubic,,,,58336.861,1561.7435,6.6068129,-283.65007,-0.12023494,-12.495749,-0.11627856,0.002277001,-0.11814833,0.032839613,-40,-17.8,4.4,54.4,,, +New_Low_Temp_Comp_Pwr_Curve,,BiCubic,,,,6274.9904,61.390661,1.6208537,129.11279,0.87411617,1.9581173,0.030293311,0.005754678,0.004653957,-0.000749905,-40,-17.8,4.4,54.4,,, +New_Med_Temp_Comp_Cap_Curve,,BiCubic,,,,61412.175,1570.8519,13.533449,-500.19524,8.1639124,-3.6895385,0.054485574,-0.088096805,0.006381584,-0.037503058,-23.3,7.2,10,60,,, +New_Med_Temp_Comp_Pwr_Curve,,BiCubic,,,,4994.0336,170.24972,2.8463891,356.79403,-6.3074704,-1.409856,0.012160476,0.076231729,-0.057527471,0.009054446,-23.3,7.2,10,60,,, +No SP Reset VSD Fan,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.070428852,0.385330201,-0.460864118,1.00920344,,,,,,,0,1,,,0.1,,"From California Energy Commision, ""Advanced Variable Air Volume System Design Guide,"" October 2004" +Old_Low_Temp_Comp_Cap_Curve,,BiCubic,,,,170751.834,6102.9037,78.2619862,-2959.43265,19.7876589,-90.9581015,0.435964768,-0.041157653,-0.60884596,0.459133262,-40,-17.8,4.4,54.4,,, +Old_Low_Temp_Comp_Pwr_Curve,,BiCubic,,,,29669.2711,1027.63205,18.1066262,-442.199714,11.1335288,-20.3804519,0.139980653,-0.058866918,-0.218451538,0.203858467,-40,-17.8,4.4,54.4,,, +Old_Med_Temp_Comp_Cap_Curve,,BiCubic,,,,151166.436,5266.34789,60.6727151,-1851.55938,5.73132755,-46.9277173,0.136401203,-0.035697884,-0.403053994,-0.039290478,-23.3,7.2,10,60,,, +Old_Med_Temp_Comp_Pwr_Curve,,BiCubic,,,,7438.92229,-269.597565,-9.85610446,553.57326,-3.38588961,14.8657878,-0.100796292,0.009822793,0.097362356,-0.039675217,-23.3,7.2,10,60,,, +Open Latent Curve,Refrigerated Case,Cubic,,,,-0.0187,0.0458,0.0011,0.00005,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings +Open-Cent-Cap-fCHWT&ECT,OpenCentrifugal,BiQuadratic,QRatio,CHWT,ECT,0.257896,0.0389016,-0.000217,0.0468684,-0.000943,-0.000343,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Open-Cent-EIR-fCHWT&ECT,OpenCentrifugal,BiQuadratic,EIRRatio,CHWT,ECT,0.933884,-0.058212,0.00450036,0.00243,0.000486,-0.001215,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Open-Cent-EIR-fPLR,OpenCentrifugal,Quadratic,EIRRatio,PLR,,0.222903,0.313387,0.46371,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Open-Rec-Cap-fCHWT&ECT,OpenReciprocatg,BiQuadratic,QRatio,CHWT,ECT,0.507883,0.1452276,-0.00625644,-0.0011178,-0.00013,-0.000282,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Open-Rec-EIR-fCHWT&ECT,OpenReciprocatg,BiQuadratic,EIRRatio,CHWT,ECT,1.030757,-0.103536,0.00710208,0.0093186,0.000318,-0.00104,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Open-Rec-EIR-fPLR,OpenReciprocatg,Quadratic,EIRRatio,PLR,,0.088065,1.137742,-0.225806,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +OpenTwr-FluidCap-fApp&WB,OpenTower,BiQuadratic,QRatio,App,WB,0.11735985,0.010588518,0.000701,0.052439526,0.000724,0.003437899,,,,,,,,,,,From .dat files included with MASControl2 +OpenTwr-FluidCap-fRng&WB,OpenTower,BiQuadratic,QRatio,Rng,WB,0.11661702,0.202450932,-0.004401443,-0.01592307,0.000101,-0.001101632,,,,,,,,,,,From .dat files included with MASControl2 +PoorCyclingAC-EIR-fPLR,CyclingAC,Cubic,EIRRatio,PLR,,0.000362523,1.32573,-0.407603,0.0818194,,,,,,,,,,,,,From .dat files included with MASControl2 +PSZ-AC DX Coil EIR-FT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.342414409,0.034885008,-0.0006237,0.004977216,0.000437951,-0.000728028,,,,,12.77778,23.88889,23.88889,46.11111,,,"From PNNL Prototype Buildings HotelSmall, Warehouse" +PSZ-AC DX Unitary Package EIRFT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.297145,0.0430933,-0.000748766,0.00597727,0.000482112,-0.000956448,,,,,12.77778,23.88889,21.11111,46.11111,,,"From PNNL Prototype Buildings RetailStandAlone, RetailStripMall,SchoolPrimary" +PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.42415,0.04426,-0.00042,0.00333,-0.00008,-0.00021,,,,,17,22,29,46,,,"From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" +PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR,DX Cooling Coil,Quadratic,EIRRatio,QRatio,,0.771,0.229,0,,,,,,,,0,1,,,,,"From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" +PSZ-AC_CoolCStandard10Ton_EIRFT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,1.23649,-0.02431,0.00057,-0.01434,0.00063,-0.00038,,,,,17,22,29,46,,,"From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" +PSZ-AC_Unitary_PackagecoolCapFT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.766956,0.0107756,-4.14703E-05,0.00134961,-0.000261144,0.000457488,,,,,12.77778,23.88889,21.11111,46.11111,,,"From PNNL Prototype Buildings RetailStandalone, RetailStripMall, SchoolPrimary" +PSZ-AC_Unitary_PackagecoolEIRFFF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.156,-0.1816,0.0256,,,,,,,,0.5,1.5,,,,, +PSZ-AC_Unitary_PackagecoolFFF,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,, +PSZ-AC_Unitary_PackagecoolPLR,DX Cooling Coil,Quadratic,EIRRatio,QRatio,,0.75,0.25,0,,,,,,,,0,1,,,,,"From PNNL Prototype Buildings RetailStandAlone, RetailStripMall, SchoolPrimary" +PSZ-AC:1_Unitary_PackagecoolEIRFFF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.156,-0.1816,0.0256,,,,,,,,0.5,1.5,,,,,"From PNNL Prototype Buildings RetailStandAlone, RetailStripMall, SchoolPrimary" +PSZ-Fine Storage DX Coil Cap-FT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.942587793,0.009543347,0.00068377,-0.011042676,0.000005249,-0.00000972,,,,,12.77778,23.88889,23.88889,46.11111,,,"From PNNL Prototype Buildings HotelSmall, Warehouse" +PSZ-Fine Storage Heating Coil PLF-FPLR,DX Heating Coil,Cubic,EIRRatio,QRatio,,0.8,0.2,0,0,,,,,,,0,1,,,,,From Prototype Buildings +PSZ-Office Heating Coil PLF-FPLR,DX Heating Coil,Cubic,EIRRatio,QRatio,,0.8,0.2,0,0,,,,,,,0,1,,,,,From Prototype Buildings +PSZ135to240_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 +PSZ135to240_BF_fT,BF_fT,BiQuadratic,,T,T,43.269632,-4.898304,0.148392,0.0947376,0.00213192,-0.0134136,,,,,,,,,0,4.04,From .dat files included with MASControl2 +PSZ135to240_CEIR_fPLR,CEIR_fPLR,Cubic,EIRRatio,PLR,,0.0184,1.15,-0.208,0.0423,,,,,,,,,,,,,From .dat files included with MASControl2 +PSZ135to240_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.62774528,-0.060192,0.00260172,-0.005653656,0.0000266,-0.00040824,,,,,,,,,,,From .dat files included with MASControl2 +PSZ135to240_CLoss_fPLR,CLoss_fPLR,Cubic,,PLR,,0.852,0.203,-0.0423,0.00938,,,,,,,,,,,0.8024,1.0728,From .dat files included with MASControl2 +PSZ135to240_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,0.4018688,0.1920384,-0.0077436,-0.01956816,-0.0000415,0.00077436,,,,,,,,,,,From .dat files included with MASControl2 +PSZ135to240_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,-0.0449056,0.07059456,-0.00216432,0.00440856,0.00041148,-0.000245916,,,,,,,,,,,From .dat files included with MASControl2 +PSZ135to240_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 +PSZ135to240_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 +PSZ240to760_BF_fFlow,BF_fFlow,Linear,QRatio,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 +PSZ240to760_BF_fT,BF_fT,BiQuadratic,,T,T,15.8724544,-1.6604928,0.041148,0.03013992,0.000278964,0.00047628,,,,,,,,,0,3.252,From .dat files included with MASControl2 +PSZ240to760_CEIR_fPLR,CEIR_fPLR,Cubic,EIRRatio,PLR,,2.63,-9.5,14.3,-6.4,,,,,,,,,,,,,From .dat files included with MASControl2 +PSZ240to760_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.27910208,-0.0291096,0.00167184,-0.002266416,-0.000031,-0.00033372,,,,,,,,,,,From .dat files included with MASControl2 +PSZ240to760_CLoss_fPLR,CLoss_fPLR,Cubic,,PLR,,0.964,0.289,0.183,-0.131,,,,,,,,,,,0.96,1.3,From .dat files included with MASControl2 +PSZ240to760_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.64083712,-0.06152112,-0.0004698,-0.010834704,-0.0000289,0.000222912,,,,,,,,,,,From .dat files included with MASControl2 +PSZ240to760_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.336608,0.0487944,-0.00116316,-0.005994,0.00067716,-0.00069012,,,,,,,,,,,From .dat files included with MASControl2 +PSZ240to760_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 +PSZ240to760_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 +PSZ65to135_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 +PSZ65to135_BF_fT,BF_fT,BiQuadratic,,T,T,14.931264,-1.5724512,0.04698,0.0015984,0.00096552,-0.00319788,,,,,,,,,0,3.509,From .dat files included with MASControl2 +PSZ65to135_CEIR_fPLR,CEIR_fPLR,Cubic,EIRRatio,PLR,,0.0184,1.15,-0.208,0.0423,,,,,,,,,,,,,From .dat files included with MASControl2 +PSZ65to135_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.2518496,-0.02766672,0.00115344,0.0035388,-0.000134136,-0.000167508,,,,,,,,,,,From .dat files included with MASControl2 +PSZ65to135_CLoss_fPLR,CLoss_fPLR,Cubic,,PLR,,0.882,0.211,-0.0439,0.0098,,,,,,,,,,,0.8323,1.1087,From .dat files included with MASControl2 +PSZ65to135_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.7733472,0.0383688,-0.0038556,-0.01090224,-0.000138348,0.00070632,,,,,,,,,,,From .dat files included with MASControl2 +PSZ65to135_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.5431072,0.03102048,-0.00090072,-0.01496592,0.0006966,-0.000199908,,,,,,,,,,,From .dat files included with MASControl2 +PSZ65to135_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 +PSZ65to135_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 +PTAC_EIR_fPLR,PkgdTerminalACS,Cubic,EIRRatio,PLR,,0.125,0.875,0,0,,,,,,,,,,,,,From .dat files included with MASControl2 +PTAC-Bypass-Factor-fAirflow,PkgdTerminalAC,Quadratic,QRatio,Airflow,,-2.28,5.21,-1.93,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +PTAC-Bypass-Factor-fEWB&EDB,PkgdTerminalAC,BiQuadratic,QRatio,EWB,EDB,-0.219664,0.0994608,0.00102,-0.020394,0.00036,-0.00120528,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +PTAC-Cool-Cap-fEWB&OAT,PkgdTerminalAC,BiQuadratic,QRatio,EWB,OAT,0.93865088,0.0095364,0.000684,-0.011038176,0.00000525,-0.00000972,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +PTAC-EIR-fEWB&OAT,PkgdTerminalAC,BiQuadratic,EIRRatio,EWB,OAT,0.34208928,0.03484368,-0.000625,0.004968864,0.000438,-0.000728,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +PTAC-EIR-fPLR,PkgdTerminalAC,Linear,EIRRatio,PLR,,0.125,0.875,,,,,,,,,,,,,,,From .dat files included with MASControl2 +PTAC-Sens-Cap-fAirflow,PkgdTerminalAC,Linear,QRatio,Airflow,,0.6,0.4,,,,,,,,,,,,,,,From .dat files included with MASControl2 +PTAC-Sens-Cap-fEWB&OAT,PkgdTerminalAC,BiQuadratic,QRatio,EWB,OAT,3.2722656,-0.14984352,0.00140292,0.0047124,-0.000162,0.000207,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +PTACHPACEIRFT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.342414409,0.034885008,-0.0006237,0.004977216,0.000437951,-0.000728028,,,,,12.77778,23.88889,18.3,46.11111,,,From DOE Reference Buildings SmallHotel +Pump-Head-fFlow,Pumps,Quadratic,QRatio,Flow,,1.3534831,33.8,-1660000,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Pump-Power-fFlow,Pumps,Quadratic,,Flow,,0.3697739,1780.65378,-943000,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +PVV240to760_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 +PVV240to760_BF_fT,BF_fT,BiQuadratic,,T,T,8.747712,-1.2544704,0.034992,0.219888,-0.00221292,-0.00284796,,,,,,,,,0,3.2,From .dat files included with MASControl2 +PVV240to760_CEIR_fPLR,CEIR_fPLR,Cubic,EIRRatio,PLR,,0.124,0.376,1.29,-0.794,,,,,,,,,,,,,From .dat files included with MASControl2 +PVV240to760_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,0.9521152,-0.01097712,0.0012312,-0.00072792,-0.0000454,-0.000173988,,,,,,,,,,,From .dat files included with MASControl2 +PVV240to760_CLoss_fPLR,CLoss_fPLR,Cubic,,PLR,,0,1,0,0,,,,,,,,,,,0.1,1,From .dat files included with MASControl2 +PVV240to760_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.91654848,0.0047736,-0.00233604,-0.013756896,-0.0000323,0.00057672,,,,,,,,,,,From .dat files included with MASControl2 +PVV240to760_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.380192,0.0241488,-0.00047952,0.0111168,0.00052488,-0.00102384,,,,,,,,,,,From .dat files included with MASControl2 +PVV240to760_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 +PVV240to760_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 +PVVT-Bypass-Factor-fAirflow,PkgdVVVT,Quadratic,QRatio,Airflow,,-0.254,1.22,0.036,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +PVVT-Bypass-Factor-fEWB&EDB,PkgdVVVT,BiQuadratic,QRatio,EWB,EDB,0.85028352,0.014256792,0.000184,-0.014791716,-0.00000548,0.000487,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +PVVT-Cool-Cap-fEWB&OAT,PkgdVVVT,BiQuadratic,QRatio,EWB,OAT,0.86783424,0.014239008,0.000554,-0.007558056,0.000033,-0.000192,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +PVVT-Cool-EIR-fEWB&OAT,PkgdVVVT,BiQuadratic,EIRRatio,EWB,OAT,0.1210048,0.0285336,-0.000411,0.02134944,0.000161,-0.00068,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +PVVT-Cool-EIR-fPLR,PkgdVVVT,Cubic,EIRRatio,PLR,,0.201,-0.0312,1.9504979,-1.1205104,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +PVVT-Heat-Cap-fEDB&OAT,PkgdVVVT,BiQuadratic,QRatio,EDB,OAT,0.74200928,0,0,0.030668544,0.0000323,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 +PVVT-Heat-EIR-fEDB&OAT,PkgdVVVT,BiQuadratic,EIRRatio,EDB,OAT,1.255664,0,0,-0.0399528,0.00108864,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 +PVVT-Heat-EIR-fPLR,PkgdVVVT,Cubic,EIRRatio,PLR,,0.0857,0.939,-0.183,0.159,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +PVVT-Sens-Cap-fEWB&OAT,PkgdVVVT,BiQuadratic,QRatio,EWB,OAT,2.93229888,-0.09445968,0.0002,-0.007173756,0.0000103,0.000109,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +Rcmp-kW-f-Tc-T1-Hi-Eff,Refrigeration,Quadratic,,Tc,,0.635620298,0.003533521,0.000161,,,,,,,,,,,,0.7533,1.2802,From .dat files included with MASControl2 +Rcmp-kW-f-Tc-T1-Low-Eff,Refrigeration,Quadratic,,Tc,,1.113461,-0.0308988,0.000739,,,,,,,,,,,,0.950084,1.606833,From .dat files included with MASControl2 +Rcmp-kW-f-Tc-T2-Hi-Eff,Refrigeration,Quadratic,,Tc,,0.580834119,0.00494838,0.000161,,,,,,,,,,,,0.7262,1.3046,From .dat files included with MASControl2 +Rcmp-kW-f-Tc-T2-Low-Eff,Refrigeration,Quadratic,,Tc,,0.970164,-0.02268,0.000625,,,,,,,,,,,,0.943908,1.565353,From .dat files included with MASControl2 +Rcmp-kW-f-Tc-T3-Hi-Eff,Refrigeration,Quadratic,,Tc,,0.358796196,0.007319986,0.000257,,,,,,,,,,,,0.5728,1.4917,From .dat files included with MASControl2 +Rcmp-kW-f-Tc-T3-Low-Eff,Refrigeration,Quadratic,,Tc,,0.656539,-0.0039924,0.00035,,,,,,,,,,,,0.941987,1.418136,From .dat files included with MASControl2 +Rcmp-kW2-f-Tc-T1-Hi-Eff,Refrigeration,Quadratic,,Tc,,0.904478102,-0.008972199,0.000303,,,,,,,,,,,,0.8518,1.2802,From .dat files included with MASControl2 +Rcmp-kW2-f-Tc-T1-Low-Eff,Refrigeration,Quadratic,,Tc,,1.113461,-0.0308988,0.000739,,,,,,,,,,,,0.950084,1.606833,From .dat files included with MASControl2 +Rcmp-kW2-f-Tc-T2-Hi-Eff,Refrigeration,Quadratic,,Tc,,0.887325182,-0.009516488,0.000328,,,,,,,,,,,,0.8326,1.3046,From .dat files included with MASControl2 +Rcmp-kW2-f-Tc-T2-Low-Eff,Refrigeration,Quadratic,,Tc,,0.970164,-0.02268,0.000625,,,,,,,,,,,,0.943908,1.565353,From .dat files included with MASControl2 +Rcmp-kW2-f-Tc-T3-Hi-Eff,Refrigeration,Quadratic,,Tc,,0.829593266,-0.014865914,0.000512,,,,,,,,,,,,0.7434,1.4917,From .dat files included with MASControl2 +Rcmp-kW2-f-Tc-T3-Low-Eff,Refrigeration,Quadratic,,Tc,,0.656539,-0.0039924,0.00035,,,,,,,,,,,,0.941987,1.418136,From .dat files included with MASControl2 +Rcond-Fan-Pwr-fPLR-ACpress,Refrigeration,Linear,,PLR,,0,1,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 +Rcond-Fan-Pwr-fPLR-Damper,Refrigeration,Linear,,PLR,,0.3,0.7,,,,,,,,,,,,,0.3,1,From .dat files included with MASControl2 +RecipAir-Cap-fCHWT&DBT,HermReciprocatg,BiQuadratic,QRatio,CHWT,DBT,1.10674018,0.040197888,0.000286,-0.009552852,0.00000522,-0.000255,,,,,,,,,,,From .dat files included with MASControl2 +RecipAir-EIR-fCHWT&DBT,HermReciprocatg,BiQuadratic,EIRRatio,CHWT,DBT,0.53866251,-0.008142246,0.000125,0.011090538,0.000164,-0.000342,,,,,,,,,,,From .dat files included with MASControl2 +RecipAir-EIR-fPLR-1Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.03892594,1.07531738,-0.10724027,-0.001050714,0.00000943,0.000536346,,,,,,,,,,,From .dat files included with MASControl2 +RecipAir-EIR-fPLR-2Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.04812248,0.69573414,0.2349389,0.000819378,-0.00000386,0.0000379,,,,,,,,,,,From .dat files included with MASControl2 +RecipAir-EIR-fPLR-3Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.03296722,0.57721251,0.33923307,0.002786436,-0.0000311,-0.000119,,,,,,,,,,,From .dat files included with MASControl2 +RecipAir-EIR-fPLR-4Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.00434876,0.61917436,0.32643354,0.003223368,-0.0000333,-0.000514206,,,,,,,,,,,From .dat files included with MASControl2 +RecipH2O-Cap-fCHWT&ECT,HermReciprocatg,BiQuadratic,QRatio,CHWT,ECT,1.0689798,0.036781398,0.000334,-0.010426122,0.0000217,-0.000208,,,,,,,,,,,From .dat files included with MASControl2 +RecipH2O-EIR-fCHWT&ECT,HermReciprocatg,BiQuadratic,EIRRatio,CHWT,ECT,0.51329254,-0.015039378,0.000362,0.015398694,0.000228,-0.000409,,,,,,,,,,,From .dat files included with MASControl2 +RecipH2O-EIR-fPLR&dT-1Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,-0.0142974,0.95360994,0.01805304,0.002822994,-0.0000199,-0.000497988,,,,,,,,,,,From .dat files included with MASControl2 +RecipH2O-EIR-fPLR&dT-2Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.02391765,0.88946915,0.07793053,-0.000474426,0.0000233,0.000324,,,,,,,,,,,From .dat files included with MASControl2 +RecipRemote-Cap-fCHWT&SCT,HermReciprocatg,BiQuadratic,QRatio,CHWT,SCT,1.27977199,0.051393222,0.000332,-0.009522792,-0.0000197,-0.000269,,,,,,,,,,,From .dat files included with MASControl2 +RecipRemote-EIR-fCHWT&SCT,HermReciprocatg,BiQuadratic,EIRRatio,CHWT,SCT,0.25314951,-0.015358788,0.000506,0.009717714,0.000171,-0.000382,,,,,,,,,,,From .dat files included with MASControl2 +RecipRemote-EIR-fPLR-1Comp/Ckt,HermReciprocatg,Quadratic,EIRRatio,PLR,,0.03521065,0.93266129,0.03212802,,,,,,,,,,,,,,From .dat files included with MASControl2 +RecipRemote-EIR-fPLR-2Comp/Ckt,HermReciprocatg,Quadratic,EIRRatio,PLR,,0.02511026,0.8934145,0.08147529,,,,,,,,,,,,,,From .dat files included with MASControl2 +Refg-Condenser-Cap-fCondT&WBT,Refrigeration,BiQuadratic,QRatio,CondT,WBT,0.15373327,0.00942813,0.000693,-0.020963196,-0.000702,0.000302,,,,,,,,,0.2,2.222,From .dat files included with MASControl2 +Refg-kW-fECT-T1,Refrigeration,Quadratic,,ECT,,0.753416,-0.0212148,0.000739,,,,,,,,,,,,0.850358,1.747334,From .dat files included with MASControl2 +Refg-kW-fECT-T2,Refrigeration,Quadratic,,ECT,,1.00323,-0.0290574,0.000765,,,,,,,,,,,,0.859029,1.592964,From .dat files included with MASControl2 +Refg-kW-fECT-T3,Refrigeration,Quadratic,,ECT,,0.671617,-0.0074358,0.000424,,,,,,,,,,,,0.873079,1.466883,From .dat files included with MASControl2 +Refg-kW-fPLR,Refrigeration,Quadratic,,PLR,,0.0383,1.08,-0.116129,,,,,,,,,,,,0.1,1.2,From .dat files included with MASControl2 +Refg-kW2-fECT-T1,Refrigeration,Quadratic,,ECT,,0.753416,-0.0212148,0.000739,,,,,,,,,,,,0.850358,1.747334,From .dat files included with MASControl2 +Refg-kW2-fECT-T2,Refrigeration,Quadratic,,ECT,,1.00323,-0.0290574,0.000765,,,,,,,,,,,,0.859029,1.592964,From .dat files included with MASControl2 +Refg-kW2-fECT-T3,Refrigeration,Quadratic,,ECT,,0.671617,-0.0074358,0.000424,,,,,,,,,,,,0.873079,1.466883,From .dat files included with MASControl2 +Residential Fix Vol-Fan EIR,FanEIR-FPLR,Linear,EIRRatio,PLR,,1,0,,,,,,,,,,,,,,,From .dat files included with MASControl2 +Residential Var Vol-Fan EIR,FanEIR-FPLR,Cubic,EIRRatio,PLR,,0.000281,-0.0579,0.586,0.471,,,,,,,,,,,,,From .dat files included with MASControl2 +RestaurantFastFood Kitchen_Case:1_WALKINFREEZERSingleShelfHorizontal_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.0236,0.0006,0,0,,,,,,,-35,20,,,,,From Prototype Buildings +RestaurantFastFood Kitchen_Case:2_SELFCONTAINEDDISPLAYCASEMultiShelfVertical_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,6.02558E-05,1.23732E-06,,,,,,,-35,20,,,,,From Prototype Buildings +RESVVT-Bypass-Factor-fAirflow,ResidentialVVVT,Quadratic,QRatio,Airflow,,-0.254,1.22,0.036,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +RESVVT-Bypass-Factor-fEWB&EDB,ResidentialVVVT,BiQuadratic,QRatio,EWB,EDB,0.85086272,0.014256792,0.000184,-0.014759136,-0.00000548,0.000487,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +RESVVT-Cool-Cap-fEWB&OAT,ResidentialVVVT,BiQuadratic,QRatio,EWB,OAT,0.47523136,0.04006368,0.000226,-0.000847152,-0.00000732,-0.000447,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +RESVVT-Cool-Cap-fRPM&OAT,ResidentialVVVT,BiQuadratic,QRatio,RPM,OAT,-686.394,-427.2546283,-66.38563967,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 +RESVVT-Cool-CondFan-fPLR&OAT,ResidentialVVVT,BiQuadratic,,PLR,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 +RESVVT-Cool-CycleLoss-fPLR,ResidentialVVVT,Linear,QRatio,PLR,,0.7,0.3,,,,,,,,,,,,,,,From .dat files included with MASControl2 +RESVVT-Cool-EIR-fEWB&OAT,ResidentialVVVT,BiQuadratic,EIRRatio,EWB,OAT,0.63153792,-0.012168288,0.000509,0.015536304,0.000273,-0.000679,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +RESVVT-Cool-EIR-fPLR,ResidentialVVVT,Linear,EIRRatio,PLR,,0,1,,,,,,,,,,,,,,,From .dat files included with MASControl2 +RESVVT-Cool-EIR-fRPM&OAT,ResidentialVVVT,BiQuadratic,EIRRatio,RPM,OAT,35.1027,10.50422626,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 +RESVVT-Cool-EIR-LoSpeed-fEWB&OAT,ResidentialVVVT,BiQuadratic,EIRRatio,EWB,OAT,0.77672128,-0.034271136,0.000784,0.01465956,0.000489,-0.000752,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +RESVVT-Cool-Waste-Heat-fEWB&OAT,ResidentialVVVT,BiLinear,QRatio,EWB,OAT,1,0,0,,,,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +RESVVT-Cool-Waste-Heat-fRPM&OAT,ResidentialVVVT,BiQuadratic,QRatio,RPM,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 +RESVVT-Heat-Cap-fEDB&OAT,ResidentialVVVT,BiQuadratic,QRatio,EDB,OAT,0.7716,0,0,0.02754,0,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 +RESVVT-Heat-Cap-fRPM&OAT,ResidentialVVVT,BiQuadratic,QRatio,RPM,OAT,-483.189,-303.9732093,-47.69188125,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 +RESVVT-Heat-CondFan-fPLR&OAT,ResidentialVVVT,BiQuadratic,,PLR,OAT,1,0,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 +RESVVT-Heat-CycleLoss-fPLR,ResidentialVVVT,Linear,QRatio,PLR,,0.75,0.25,,,,,,,,,,,,,,,From .dat files included with MASControl2 +RESVVT-Heat-EIR-fEDB&OAT,ResidentialVVVT,BiQuadratic,EIRRatio,EDB,OAT,1.1544,0,0,-0.02448,0.000729,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 +RESVVT-Heat-EIR-fPLR,ResidentialVVVT,Linear,EIRRatio,PLR,,0,1,,,,,,,,,,,,,,,From .dat files included with MASControl2 +RESVVT-Heat-EIR-fRPM&OAT,ResidentialVVVT,BiQuadratic,EIRRatio,RPM,OAT,31.9068,9.520648707,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 +RESVVT-Heat-EIR-LoSpeed-fEDB&OAT,ResidentialVVVT,BiQuadratic,EIRRatio,EDB,OAT,1.25435136,0,0,-0.040685472,0.001209784,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 +RESVVT-Heat-Waste-Heat-fEDB&OAT,ResidentialVVVT,BiLinear,QRatio,EDB,OAT,1,0,0,,,,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 +RESVVT-Heat-Waste-Heat-fRPM&OAT,ResidentialVVVT,BiQuadratic,QRatio,RPM,OAT,1,0,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 +RESVVT-Sens-Cap-fEWB&OAT,ResidentialVVVT,BiLinear,QRatio,EWB,OAT,2.78672,-0.08208,-0.005292,,,,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +RESYS-Bypass-Factor-fAirflow,Residential#1,Quadratic,QRatio,Airflow,,-3.01,6.59,-2.57,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +RESYS-Bypass-Factor-fEWB&EDB,Residential#1,BiQuadratic,QRatio,EWB,EDB,-1.1641344,0.20453184,-0.000603,-0.03036096,0.00036,-0.001464804,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +RESYS-Bypass-Factor-fPLR,ResidentialVVVT,Linear,QRatio,PLR,,1,0,,,,,,,,,,,,,,,From .dat files included with MASControl2 +RESYS-Cool-Cap-fEWB&OAT,Residential#1,BiQuadratic,QRatio,EWB,OAT,0.7665024,0.01076904,-0.0000415,0.00133848,-0.000261,0.000457,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +RESYS-Cool-EIR-fEWB&OAT,Residential#1,BiQuadratic,EIRRatio,EWB,OAT,0.29770688,0.04314528,-0.000748,0.005972688,0.000482,-0.000956,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +RESYS-Cool-EIR-fPLR,,Cubic,EIRRatio,PLR,,0.0000626,1.18,-0.202,0.0263344,,,,,,,,,,,,,From .dat files included with MASControl2 +RESYS-Heat-Cap-fEDB&OAT,Residential#1,BiQuadratic,QRatio,EDB,OAT,0.7516064,0,0,0.02799072,0.00019,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 +RESYS-Heat-EIR-fEDB&OAT,Residential#1,BiQuadratic,EIRRatio,EDB,OAT,1.231072,0,0,-0.0334944,0.000739,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 +RESYS-Heat-EIR-fPLR,Residential#1,Cubic,EIRRatio,PLR,,0.0857,0.939,-0.1834361,0.15897022,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +RESYS-Sens-Cap-fAirflow,Residential#1,Linear,QRatio,Airflow,,0.6,0.4,,,,,,,,,,,,,,,From .dat files included with MASControl2 +RESYS-Sens-Cap-fEWB&OAT,Residential#1,BiQuadratic,QRatio,EWB,OAT,3.3127968,-0.1617552,0.00184356,0.01027584,-0.000156,-0.0000284,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +SAC Heating Coil PLF-FPLR,DX Heating Coil,Cubic,EIRRatio,QRatio,,0.8,0.2,0,0,,,,,,,0,1,,,,,From Prototype Buildings +SchoolPrimary Kitchen_ZN_1_FLR_1_Case:1_WALKINFREEZERSingleShelfHorizontal_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.0236,0.0006,0,0,,,,,,,-35,20,,,,,From Prototype Buildings +SchoolPrimary Kitchen_ZN_1_FLR_1_Case:2_SELFCONTAINEDDISPLAYCASEMultiShelfVertical_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,6.02558E-05,1.23732E-06,,,,,,,-35,20,,,,,From Prototype Buildings +ScrewAir-Cap-fCHWT&DBT,Screw,BiQuadratic,QRatio,CHWT,DBT,0.97878647,0.02387169,0.000587,-0.0000478,-0.000112,-0.00011,,,,,,,,,,,From .dat files included with MASControl2 +ScrewAir-EIR-fCHWT&DBT,Screw,BiQuadratic,EIRRatio,CHWT,DBT,0.6729704,-0.005730012,0.000702,-0.00119601,0.00044,-0.000699,,,,,,,,,,,From .dat files included with MASControl2 +ScrewAir-EIR-fPLR&dT-1Comp/Ckt,Screw,BiQuadratic,EIRRatio,PLR,dT,0.01040687,1.05183303,-0.09462459,0.002943774,-0.0000252,-0.001085832,,,,,,,,,,,From .dat files included with MASControl2 +ScrewAir-EIR-fPLR&dT-2Comp/Ckt,Screw,BiQuadratic,EIRRatio,PLR,dT,0.09611014,0.72898877,0.19517007,-0.000729072,0.00000667,-0.000175,,,,,,,,,,,From .dat files included with MASControl2 +ScrewH2O-Cap-fCHWT&ECT,Screw,BiQuadratic,QRatio,CHWT,ECT,1.07096667,0.02693502,0.000768,-0.00643302,-0.0000949,-0.0000659,,,,,,,,,,,From .dat files included with MASControl2 +ScrewH2O-EIR-fCHWT&ECT,Screw,BiQuadratic,EIRRatio,CHWT,ECT,0.59849788,-0.00123345,0.000563,0.001602738,0.000636,-0.001094148,,,,,,,,,,,From .dat files included with MASControl2 +ScrewH2O-EIR-fPLR&dT-1Comp/Ckt,Screw,BiQuadratic,EIRRatio,PLR,dT,-0.11699212,1.2635448,-0.2194667,0.005301648,0.0000547,-0.003346506,,,,,,,,,,,From .dat files included with MASControl2 +ScrewH2O-EIR-fPLR&dT-2Comp/Ckt,Screw,BiQuadratic,EIRRatio,PLR,dT,-0.27111483,1.49009538,-0.33198115,0.017556084,-0.000191,-0.008247186,,,,,,,,,,,From .dat files included with MASControl2 +ScrewRemote-Cap-fCHWT&SCT,Screw,BiQuadratic,QRatio,CHWT,SCT,1.16410009,0.048370122,0.000493,-0.002428218,-0.000109,-0.000269,,,,,,,,,,,From .dat files included with MASControl2 +ScrewRemote-EIR-fCHWT&SCT,Screw,BiQuadratic,EIRRatio,CHWT,SCT,0.79518287,-0.009101466,0.001707804,-0.015352632,0.000488,-0.000932,,,,,,,,,,,From .dat files included with MASControl2 +ScrewRemote-EIR-fPLR-1Comp/Ckt,Screw,Quadratic,EIRRatio,PLR,,0.07043035,1.01683199,-0.08726242,,,,,,,,,,,,,,From .dat files included with MASControl2 +ScrewRemote-EIR-fPLR-2Comp/Ckt,Screw,Quadratic,EIRRatio,PLR,,0.08138224,0.72724819,0.19136968,,,,,,,,,,,,,,From .dat files included with MASControl2 +ScrollChlrAirCoolCap-fCHW&OAT,Chiller,BiQuadratic,QRatio,CHWT,OAT,1.05229229,0.033560892,0.000215,-0.005180832,-0.0000442,-0.000215,,,,,,,,,,,From .dat files included with MASControl2 +ScrollChlrAirCoolEIR-fCHW&OAT,Chiller,BiQuadratic,EIRRatio,CHWT,OAT,0.58333562,-0.004036194,0.000468,-0.000224478,0.000481,-0.000682,,,,,,,,,,,From .dat files included with MASControl2 +ScrollChlrAirCoolEIR-fPLR,Chiller,Quadratic,EIRRatio,PLR,,0.03366649,0.53152555,0.43480802,,,,,,,,,,,,,,From .dat files included with MASControl2 +Si-Film_Spectral-fAirMass,PV-Module,Cubic,,AirMass,,0.95691782,0.04079713,-0.00869376,0.00042887,,,,,,,,,,,,,From .dat files included with MASControl2 +Single Shelf Horizontal Latent Energy Multiplier_After2004,Refrigerated Case,Cubic,,,,0.0236,0.0006,0,0,,,,,,,-35,20,,,,,From Reference Buildings +Single Shelf Horizontal Latent Energy Multiplier_Pre2004,Refrigerated Case,Cubic,,,,0.020376,0.00024378,0.0000114,1.811E-07,,,,,,,-35,20,,,,,From Reference Buildings +Single zone VAV fan,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.027827882,0.026583195,-0.0870687,1.03091975,,,,,,,0,1,,,0.1,,Baseline for System Type 11 from ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method +Small-CHW-Bypass-fAirflow,CHWCoils,Quadratic,QRatio,Airflow,,-0.718,1.91,-0.189,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Small-CHW-Coil-Bypass-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,1.09657216,0.001908,0.000369,-0.005647032,0.0000246,-0.000277,,,,,15.55556,29.44444,12.77778,29.44444,,,From .dat files included with MASControl2 +Small-CHW-Coil-Cap-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,-0.282048,-0.022212,0.0054432,0.0297216,0.000804,-0.0033372,,,,,15.55556,29.44444,12.77778,29.44444,,,From .dat files included with MASControl2 +Small-CHW-Sens-Cap-fAirflow,CHWCoils,Quadratic,QRatio,Airflow,,0.155,1.01,-0.16,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Small-CHW-Sens-Cap-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,-0.415152,-0.0405576,0.00140616,0.086508,0.000444,-0.00184356,,,,,12.77778,29.44444,12.77778,29.44444,,,From .dat files included with MASControl2 +Smooth_Optical-fAOI,PV-Module,Cubic,,AOI,,3.76248479,-0.15946805,0.00302191,-0.0000191,,,,,,,,,,,,,From .dat files included with MASControl2 +Split DX Coil EIR-FF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.1552,-0.1808,0.0256,,,,,,,,0.5,1.5,,,,,"From PNNL Prototype Buildings ApartmentMidRise, HotelSmall, Warehouse" +SpltAC1Sp_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 +SpltAC1Sp_BF_fT,BF_fT,BiQuadratic,,T,T,8.513632,-0.630072,0.0165888,-0.0450144,0.00107892,-0.0018954,,,,,,,,,0,3.33,From .dat files included with MASControl2 +SpltAC1Sp_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0.00007,1.23,-0.307,0.0756,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,0.00012,1.2,-0.261,0.0596,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.00007,1.17,-0.213,0.0438,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,0.67916,0.016938,0.00069336,0.0045576,-0.0000842,-0.00047628,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC1Sp_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.805,0.233,-0.038,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.827,0.203,-0.03,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.852,0.17,-0.0219,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.7311616,-0.10297296,0.00093636,0.00477864,-0.0000907,-0.000202824,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.7390464,-0.00778968,0.000128304,-0.00027,0.0006642,-0.000648,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC1Sp_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC1Sp_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC1Sp-ge45_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 +SpltAC1Sp-ge45_BF_fT,BF_fT,BiQuadratic,,T,T,16.900064,-1.747584,0.050544,0.1428912,0.00048924,-0.0090396,,,,,,,,,0,3.76,From .dat files included with MASControl2 +SpltAC1Sp-ge45_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0,1.18,-0.223,0.0468,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-ge45_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,0.00008,1.15,-0.183,0.0343,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-ge45_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.0001,1.12,-0.14,0.0225,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-ge45_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.2403136,-0.0346752,0.00187596,0.00106848,-0.000057,-0.0003564,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC1Sp-ge45_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.847,0.177,-0.0235,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-ge45_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.869,0.149,-0.0172,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-ge45_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.893,0.118,-0.0112,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-ge45_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.8260768,0.0199944,-0.00284148,-0.01422576,-0.0000577,0.00064152,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-ge45_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.093776,0.0674784,-0.00192132,-0.0031176,0.00067068,-0.0005832,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC1Sp-ge45_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC1Sp-ge45_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC1Sp-lt45_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 +SpltAC1Sp-lt45_BF_fT,BF_fT,BiQuadratic,,T,T,22.932224,-2.291616,0.063504,0.0800712,0.00076464,-0.0068364,,,,,,,,,0,3.3,From .dat files included with MASControl2 +SpltAC1Sp-lt45_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0,1.18,-0.223,0.0468,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-lt45_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,0.00008,1.15,-0.183,0.0343,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-lt45_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.0001,1.12,-0.14,0.0225,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-lt45_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.1299744,-0.0222336,0.0015228,-0.0000353,-0.0000434,-0.00032724,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC1Sp-lt45_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.847,0.177,-0.0235,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-lt45_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.869,0.149,-0.0172,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-lt45_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.893,0.118,-0.0112,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-lt45_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.4985024,0.0478512,-0.0034992,-0.01084968,-0.0000548,0.00047628,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-lt45_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.09712,0.0536256,-0.00144828,0.0040644,0.00062208,-0.000729,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC1Sp-lt45_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC1Sp-lt45_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC2SpHiSEER_BF_fFlow,BF_fFlow,Linear,,Flow,,1.75,-1578.5656,,,,,,,,,,,,,1,1.189,From .dat files included with MASControl2 +SpltAC2SpHiSEER_BF_fT,BF_fT,BiQuadratic,,T,T,20.03024,-1.922832,0.051516,0.086184,0.0011502,-0.0076788,,,,,,,,,0,3.92,From .dat files included with MASControl2 +SpltAC2SpHiSEER_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0.00635,1.12,-0.139,0.016,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC2SpHiSEER_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,-0.00144,1.12,-0.14,0.022,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC2SpHiSEER_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.00726,1.11,-0.132,0.0262,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC2SpHiSEER_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.5240096,-0.0665928,0.00299376,0.00162288,-0.0000651,-0.00048924,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC2SpHiSEER_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.923,0.153,-0.0156,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC2SpHiSEER_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.94,0.124,-0.0109,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC2SpHiSEER_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.959,0.0934,-0.00688,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC2SpHiSEER_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.54,0.0382752,-0.00297756,-0.0114912,-0.00010044,0.0005346,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC2SpHiSEER_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,-0.172512,0.1176624,-0.00324,-0.01152,0.00077112,-0.00057024,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC2SpHiSEER_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC2SpHiSEER_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC2SpLoSEER_BF_fFlow,BF_fFlow,Linear,,Flow,,1.75,-1578.5656,,,,,,,,,,,,,1,1.189,From .dat files included with MASControl2 +SpltAC2SpLoSEER_BF_fT,BF_fT,BiQuadratic,,T,T,10.820416,-1.041264,0.0254988,0.2290608,0.00062856,-0.0117612,,,,,,,,,0,5.76,From .dat files included with MASControl2 +SpltAC2SpLoSEER_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,-0.00016,1.12,-0.143,0.0206,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC2SpLoSEER_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,-0.00146,1.1,-0.119,0.0176,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC2SpLoSEER_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,0.00284,1.06,-0.0687,0.00523,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC2SpLoSEER_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.54887488,-0.0648072,0.00310068,-0.000425376,-0.0000255,-0.00060264,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC2SpLoSEER_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.856,0.121,-0.0124,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC2SpLoSEER_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.872,0.0941,-0.00752,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC2SpLoSEER_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.889,0.0695,-0.00646,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC2SpLoSEER_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.322048,-0.0286956,-0.00124092,-0.020124,-0.0000405,0.0006804,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC2SpLoSEER_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,-0.281376,0.1343088,-0.0036936,-0.0173736,0.00096552,-0.00075168,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC2SpLoSEER_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC2SpLoSEER_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltACEvap_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 +SpltACEvap_BF_fT,BF_fT,BiQuadratic,,T,T,16.06,-1.566,0.0405,1.75E-10,3.24E-12,3.24E-12,,,,,,,,,0,3.97,From .dat files included with MASControl2 +SpltACEvap_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0,1,0,0,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltACEvap_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,0,1,0,0,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltACEvap_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,0,1,0,0,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltACEvap_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,0.6302064,0.0171576,0.00069012,-0.00374688,0.000212544,-0.0005508,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltACEvap_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.94,0.06,0,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltACEvap_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.97,0.03,0,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltACEvap_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,1,0,0,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltACEvap_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.9516064,-0.0154008,-0.0012798,-0.00110088,0.000194724,-0.00054432,,,,,,,,,,,From .dat files included with MASControl2 +SpltACEvap_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,1.207232,-0.0528552,0.00053136,0.0261288,-0.00045684,0.0005508,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltACEvap_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltACEvap_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltHP1SpCom_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 +SpltHP1SpCom_BF_fT,BF_fT,BiQuadratic,,T,T,8.513632,-0.630072,0.0165888,-0.0450144,0.00107892,-0.0018954,,,,,,,,,0,3.33,From .dat files included with MASControl2 +SpltHP1SpCom_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0.00007,1.23,-0.307,0.0756,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpCom_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,0.00012,1.2,-0.261,0.0596,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpCom_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.00007,1.17,-0.213,0.0438,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpCom_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,0.67916,0.016938,0.00069336,0.0045576,-0.0000842,-0.00047628,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltHP1SpCom_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.805,0.233,-0.038,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpCom_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.827,0.203,-0.03,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpCom_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.852,0.17,-0.0219,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpCom_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.7311616,-0.10297296,0.00093636,0.00477864,-0.0000907,-0.000202824,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpCom_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.7390464,-0.00778968,0.000128304,-0.00027,0.0006642,-0.000648,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltHP1SpCom_HIR_fT,HIR_fT,BiQuadratic,,T,T,0.8186976,0.01406952,0.000117936,-0.01579104,0.000222264,-0.000300024,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltHP1SpCom_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0.85516576,-0.003631392,-0.00000619,0.02644704,0.00041148,-0.000141264,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltHP1SpRes_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 +SpltHP1SpRes_BF_fT,BF_fT,BiQuadratic,,T,T,8.513632,-0.630072,0.0165888,-0.0450144,0.00107892,-0.0018954,,,,,,,,,0,3.33,From .dat files included with MASControl2 +SpltHP1SpRes_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0.00007,1.23,-0.307,0.0756,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpRes_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,0.00012,1.2,-0.261,0.0596,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpRes_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.00007,1.17,-0.213,0.0438,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpRes_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,0.67916,0.016938,0.00069336,0.0045576,-0.0000842,-0.00047628,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltHP1SpRes_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.805,0.233,-0.038,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpRes_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.827,0.203,-0.03,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpRes_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.852,0.17,-0.0219,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpRes_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.7311616,-0.10297296,0.00093636,0.00477864,-0.0000907,-0.000202824,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpRes_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.7390464,-0.00778968,0.000128304,-0.00027,0.0006642,-0.000648,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltHP1SpRes_HIR_fT,HIR_fT,BiQuadratic,,T,T,0.9003872,0.01108728,0.0001701,-0.02579472,0.0008424,-0.000290628,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltHP1SpRes_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0.9303344,-0.0064656,0.0000177,0.02813472,-0.00000551,-0.000208656,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltHP2Sp_BF_fFlow,BF_fFlow,Linear,,Flow,,1.75,-1578.5656,,,,,,,,,,,,,1,1.189,From .dat files included with MASControl2 +SpltHP2Sp_BF_fT,BF_fT,BiQuadratic,,T,T,20.03024,-1.922832,0.051516,0.086184,0.0011502,-0.0076788,,,,,,,,,0,3.92,From .dat files included with MASControl2 +SpltHP2Sp_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0.00635,1.12,-0.139,0.016,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP2Sp_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,-0.00144,1.12,-0.14,0.022,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP2Sp_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.00726,1.11,-0.132,0.0262,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP2Sp_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.5240096,-0.0665928,0.00299376,0.00162288,-0.0000651,-0.00048924,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltHP2Sp_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.923,0.153,-0.0156,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP2Sp_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.94,0.124,-0.0109,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP2Sp_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.959,0.0934,-0.00688,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP2Sp_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.54,0.0382752,-0.00297756,-0.0114912,-0.00010044,0.0005346,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP2Sp_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,-0.172512,0.1176624,-0.00324,-0.01152,0.00077112,-0.00057024,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltHP2Sp_HIR_fT,HIR_fT,BiQuadratic,,T,T,0.9272864,0.00802008,0.000201528,-0.02177136,0.000729,-0.000303264,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltHP2Sp_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0.8756304,-0.00466344,1.62E-14,0.02912976,0.00012636,-0.000163296,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SteamTurbine-Flow-fPSIG,SteamTurbineGen,BiQuadratic,QRatio,PSIG,PSIG,38.79236,-0.0000307,1.11E-11,0.000147951,1.93E-11,-7.36E-11,,,,,,,,,18,100,From .dat files included with MASControl2 +SteamTurbine-HIR-fPLR,SteamTurbineGen,Quadratic,,PLR,,0.12838545,0.90049523,-0.02888074,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Stippled_Optical-fAOI,PV-Module,Cubic,,AOI,,4.70208168,-0.21138079,0.00393233,-0.000024,,,,,,,,,,,,,From .dat files included with MASControl2 +SWH-EFFFPLR-NECB2011,Water Heater,Cubic,FIRRatio,QRatio,,0.7576,1.0071,-1.4443,0.6844,,,,,,,0,1,,,,,From NECB 2011 +Tower_Fan_Curve,,Cubic,,,,0,0,0,1,,,,,,,0,1,,,,,From Prototype Buildings +Transformer-Loss-fPLR,ElecMeters,Linear,QRatio,PLR,,0.1,0.9,,,,,,,,,,,,,,,From .dat files included with MASControl2 +Two-Speed Fan EIR fPLR,FanEIR-FPLR,Linear,,PLR,,-0.764706,1.764706,,,,,,,,,,,,,0.4,,From .dat files included with MASControl2 +TwoSpeedFan,FanEIR-FPLR,Cubic,EIRRatio,PLR,,0.000281,-0.0579,0.586,0.471,,,,,,,,,,,,,From .dat files included with MASControl2 +Typical VSD Fan,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.047182815,0.130541742,-0.117286942,0.940313747,,,,,,,0,1,,,0.1,,"From California Energy Commision, ""Advanced Variable Air Volume System Design Guide,"" October 2003" +TypicalCyclingAC-EIR-fPLR,CyclingAC,Cubic,EIRRatio,PLR,,0.0000626,1.17517,-0.201513,0.0263344,,,,,,,,,,,,,From .dat files included with MASControl2 +Vane Axial w Var Pitch FPLR,FanEIR-FPLR,Quadratic,,PLR,,0.212048,-0.569286,1.345238,,,,,,,,,,,,0.15,1,From .dat files included with MASControl2 +Variable Speed Drive FPLR,FanEIR-FPLR,Quadratic,,PLR,,0.219762,-0.874784,1.652597,,,,,,,,,,,,0.1,1,From .dat files included with MASControl2 +VarVolFan-AFBIFanCurve-NECB2011-FPLR,Fan,Cubic,PwrRatio,FlowRatio,,-2.4176,9.5874,-11.559,5.4009,,,,,,,0.68,1,,,,,From NECB 2011 +VarVolFan-AFBIInletVanes-NECB2011-FPLR,Fan,Cubic,PwrRatio,FlowRatio,,-4.1457,16.803,-19.471,7.8488,,,,,,,0.5,1,,,,,From NECB 2011 +VarVolFan-FCInletVanes-NECB2011-FPLR,Fan,Cubic,PwrRatio,FlowRatio,,-0.3477,4.0976,-5.0024,2.268,,,,,,,0.22,1,,,,,From NECB 2011 +VarVolFan-VSD-NECB2011-FPLR,Fan,Cubic,PwrRatio,FlowRatio,,0.1389,1.7699,-1.615,0.6996,,,,,,,0.04,1,,,,,From NECB 2011 +VFD-Loss-fPLR,Pumps,Linear,QRatio,PLR,,0.6,0.4,,,,,,,,,,,,,,,From .dat files included with MASControl2 +VRF-HP-Resys-ClCap-fSST&ODB,CondUnit,BiQuadratic,QRatio,SST,ODB,1.26588416,0,0,-0.007582032,-0.00000214,0,,,,,,,,,,,From .dat files included with MASControl2 +VRF-HP-Resys-ClEIR-fSST&ODB,CondUnit,BiQuadratic,EIRRatio,SST,ODB,0.384832,0,0,0.0092304,0.000238,0,,,,,,,,,,,From .dat files included with MASControl2 +VRF-HP-Resys-Crankcase-fPLR,CondUnit,Quadratic,,PLR,,1,-1.72,0.72,,,,,,,,,,,,,,From .dat files included with MASControl2 +VRF-HP-Resys-Cycle-fPLR,CondUnit,Linear,QRatio,PLR,,0.898,0.102,,,,,,,,,,,,,,,From .dat files included with MASControl2 +VRF-HP-Resys-HtCap-fSCT&OWB,CondUnit,BiQuadratic,QRatio,SCT,OWB,0.89783456,0,0,0.016707888,0.000000616,0,,,,,,,,,,,From .dat files included with MASControl2 +VRF-HP-Resys-HtEIR-fSCT&OWB,CondUnit,BiQuadratic,EIRRatio,SCT,OWB,1.0525344,0,0,-0.00815688,-0.0000872,0,,,,,,,,,,,From .dat files included with MASControl2 +VSD-TWR-FAN-FPLR,Cooling Tower,Cubic,,,,0.33162901,-0.88567609,0.60556507,0.9484823,,,,,,,0,1,,,,,From PNNL PRM Reference Manual +Water-Cooled-Bypass-fAirflow,"DXCooling,WCC",Cubic,QRatio,Airflow,,0.9,-3.73,7.37,-3.54,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Water-Cooled-Bypass-fEWB&EWT,"DXCooling,WCC",BiQuadratic,QRatio,EWB,EWT,-5.51104768,0.73563552,-0.0185004,0.142520616,0.000942,-0.010213452,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +Water-Cooled-Cool-Cap-fEWB&EWT,"DXCooling,WCC",BiQuadratic,QRatio,EWB,EWT,0.8254384,0.00574416,0.000735,-0.00310374,-0.0000146,-0.000194,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +Water-Cooled-EIR-fEWB&EWT,"DXCooling,WCC",BiQuadratic,EIRRatio,EWB,EWT,0.0985984,0.062604,-0.00184356,0.01183032,0.000292,-0.000395,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +Water-Cooled-EIR-fPLR,"DXCooling,WCC",Cubic,EIRRatio,PLR,,0.201,-0.0312,1.9504979,-1.1205104,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Water-Cooled-Sens-Cap-fEWB&EWT,"DXCooling,WCC",BiQuadratic,QRatio,EWB,EWT,2.1542784,-0.0242784,-0.00148716,-0.00829548,-0.0000296,0.000272,,,,,12.77778,29.44444,10,46.11111,,,From .dat files included with MASControl2 +WaterCooled_Centrifugal_CAPFT_NECB2011,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.707908,-0.00200657,-0.00259605,0.0300588,-0.00105643,0.0020457,,,,,5,10,24,35,,,From NECB 2011 +WaterCooled_Centrifugal_Chiller_150TO300_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_150TO300_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_150TO300_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.7600172,0.0147432,0.0002144,0.0207218,-0.0006425,0.0008007,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.6772577,0.0117857,-0.0001967,0.0014414,0.0003005,-0.0006807,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.536234,0.005581,-0.0013654,0.0488966,-0.0012018,0.0010523,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,1.0821822,0.0042977,-0.0013182,-0.0260781,0.0008256,-0.0006013,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_300TO600_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_300TO600_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_AllCapacities_2004_2007_2010_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010. EIRFPLR curve is identical for all WaterCooled Chillers" +WaterCooled_Centrifugal_Chiller_GT150_2004_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.7600172,0.0147432,0.0002144,0.0207218,-0.0006425,0.0008007,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_GT150_2004_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.6772577,0.0117857,-0.0001967,0.0014414,0.0003005,-0.0006807,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_GT300_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_GT600_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_GT600_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_LT150_2004_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.7446451,0.0114858,0.0000148,0.022401,-0.000688,0.0009839,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.772877,0.022101,-0.0000799,-0.0070045,0.0004763,-0.0010612,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_LT150_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_LT150_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_EIRFPLR_NECB2011,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.171493,0.588202,0.237373,,,,,,,,0,1,,,,,From NECB 2011 +WaterCooled_Centrifugal_EIRFT_NECB2011,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.560523,-0.0137816,6.56424E-05,0.0132194,0.000268596,-0.000501131,,,,,5,10,24,35,,,From NECB 2011 +WaterCooled_PositiveDisplacement_Chiller_150TO300_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_150TO300_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_150TO300_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_2004_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.906115,0.029227,-0.0003647,-0.0009709,-0.0000905,0.0002527,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_2004_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.3617105,-0.0229833,0.0009519,0.0131889,0.0003752,-0.0007059,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_2010_PathB_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.9061171,0.0292267,-0.0003665,-0.0009698,-0.0000907,0.0002535,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_2010_PathB_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.3617782,-0.0230016,0.0009672,0.0131801,0.0003761,-0.0007121,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_75TO150_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_75TO150_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_75TO150_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.906115,0.0292277,-0.0003647,-0.0009709,-0.0000905,0.0002527,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.3773115,-0.0229032,0.0016504,0.0118156,0.0004345,-0.0010132,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_GT300_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_GT300_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_GT300_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.906115,0.0292277,-0.0003647,-0.0009709,-0.0000905,0.0002527,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.3617105,-0.0229833,0.0009519,0.0131889,0.0003752,-0.0007059,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_LT75_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_LT75_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_LT75_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Reciprocating_CAPFT_NECB2011,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.03031,0.0334698,0.00023639,-0.00729587,-0.000023166,-0.000148943,,,,,5,10,24,35,,,From NECB 2011 +WaterCooled_Reciprocating_EIRFPLR_NECB2011,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.081441,0.419271,0.499396,,,,,,,,0,1,,,,,From NECB 2011 +WaterCooled_Reciprocating_EIRFT_NECB2011,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.499699,-0.0130841,0.000266425,0.0165925,0.000185393,-0.000375646,,,,,5,10,24,35,,,From NECB 2011 +WaterCooled_Screw_CAPFT_NECB2011,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.812998,-0.0142532,-0.00161799,0.0263844,-0.00091543,0.00169601,,,,,5,10,24,35,,,From NECB 2011 +WaterCooled_Screw_EIRFPLR_NECB2011,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.330188,0.235543,0.460708,,,,,,,,0,1,,,,,From NECB 2011 +WaterCooled_Screw_EIRFT_NECB2011,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.638103,0.00630158,0.00092327,-0.00455294,0.000825682,-0.00156152,,,,,5,10,24,35,,,From NECB 2011 +WaterCooled_Scroll_CAPFT_NECB2011,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.94418,0.0337102,9.75564E-05,-0.00322114,-4.91832E-05,-0.000177584,,,,,5,10,24,35,,,From NECB 2011 +WaterCooled_Scroll_EIRFPLR_NECB2011,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.04412,0.640367,0.319555,,,,,,,,0,1,,,,,From NECB 2011 +WaterCooled_Scroll_EIRFT_NECB2011,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.727393,-0.0118922,0.000541177,0.00187934,0.000473461,-0.000711472,,,,,5,10,24,35,,,From NECB 2011 +WC Screw Default 90.1-2004 Cap_fTWC,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.906115,0.0292277,-0.0003647,-0.0009709,-0.0000905,0.0002527,,,,,0,20,0,50,,,From RefBldgLargeOfficePost1980 & Pre1980 +WC Screw Default 90.1-2004 EIR_fT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.3617105,-0.0229833,-0.0009519,0.0131889,0.0003752,-0.0007059,,,,,0,20,0,50,,,From RefBldgLargeOfficePost1980 % Pre1980 +WC Screw GTE 300tons Default 90.1-2004 EIR_fPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.2737954,0.02822257,-8.09766E-05,0.9612284,0.3029741,-0.02421933,0,-0.03885224,0,0,18.54,31.63,0.2,1.02,,,From RefBldgLargeOfficePost1980 & Pre1980 +WC_PD_2004_CAPFT,,BiQuadratic,,,,0.906115,0.0292277,-0.0003647,-0.0009709,-0.0000905,0.0002527,,,,,5,10,17.78,46.11,,,From PNNL Prototype Hospital +WC_PD_2010_PB_CAPFT,,BiQuadratic,,,,0.9061171,0.0292267,-0.0003665,-0.0009698,-0.0000907,0.0002535,,,,,5,10,17.78,46.11,,,From PNNL Prototype OfficeLarge +WC_PD_2010_PB_EIRFT,,BiQuadratic,,,,0.3617782,-0.0230016,0.0009672,0.0131801,0.0003761,-0.0007121,,,,,5,10,17.78,46.11,,,From PNNL Prototype OfficeLarge +MT_compressor_power,Refrigeration,BiCubic,Power,Suction T,Discharge T,7438.92229,-269.59756,-9.8561045,553.57326,-3.3858896,14.8657878,-0.1007963,0.00982279,0.09736236,-0.039675217,-23.3,7.2,10,60,,,From AEDG +MT_compressor_capacity,Refrigeration,BiCubic,Capacity,Suction T,Discharge T,151166.436,5266.34789,60.6727151,-1851.5594,5.73132755,-46.927717,0.1364012,-0.0356979,-0.403054,-0.039290478,-23.3,-7.2,10,60,,,From AEDG +MT_compressor_capacity_smallandold,Refrigeration,BiCubic,Capacity,Suction T,Discharge T,15000,541.8,7.285,-118,-0.3645,-3.05,0.0344,0.00225,-0.03927,-0.007307,-17.8,4.4,10,48.9,,,From EP DataSets +MT_compressor_power_smallandold,Refrigeration,BiCubic,Power,Suction T,Discharge T,483.6,-53.2,-1.384,56.19,0.003688,1.439,-0.008268,-0.00281,0.007222,0.006025,-17.8,4.4,10,48.9,,,From EP DataSets +LT_compressor_capacity_smallandold,Refrigeration,BiCubic,Capacity,Suction T,Discharge T,23500,816.7,10.7,-28.24,0.1131,-0.4553,0.05604,-0.00412,-0.006728,0.006782,-40,-17.8,10,48.9,,,From EP DataSets +LT_compressor_power_smallandold,Refrigeration,BiCubic,Power,Suction T,Discharge T,4018,95,1.507,5.705,1.247,-1.381,0.01277,-0.007518,-0.02424,0.02917,-40,-17.8,10,48.9,,,From EP DataSets +Glass Door Latent Curve Case,Refrigeration,Cubic,,,,0.3379,0.0309,0.0005,0.00004,,,,,,,-55,55,,,,,From AEDG +Coffin Latent Curve Case,Refrigeration,Cubic,,,,0.3379,0.0309,0.0005,0.00004,,,,,,,-55,55,,,,,From AEDG +Open Latent Curve Case,Refrigeration,Cubic,,,,-0.0187,0.0458,0.0011,0.00005,,,,,,,-55,55,,,,,From AEDG +Glass Door Defrost Curve Walkin,Refrigeration,Cubic,,,,0.3475,0.0296,0.0007,0.00003,,,,,,,-55,55,,,,,From AEDG +Coffin Defrost Curve Walkin,Refrigeration,Cubic,,,,0.3475,0.0296,0.0007,0.00003,,,,,,,-55,55,,,,,From AEDG +Open Defrost Curve Walkin,Refrigeration,Cubic,,,,0.0572,0.0461,0.0004,0.00006,,,,,,,-55,55,,,,,From AEDG +Refrigeration Case Latent Credit Curve,Refrigeration,Cubic,,,,0.026526281,0.001078032,6.02558E-05,1.23732E-06,,,,,,,-35,20,,,,, diff --git a/data/openstudio_standards_data/initial_data/support_standard_templates.csv b/data/openstudio_standards_data/initial_data/support_standard_templates.csv new file mode 100644 index 0000000000..66f2b3ab50 --- /dev/null +++ b/data/openstudio_standards_data/initial_data/support_standard_templates.csv @@ -0,0 +1,3 @@ +id,template,lighting_standard,lighting_standard_table,ventilation_standard,ventilation_standard_table +1,90.1-2019,ASHRAE 90.1-2019,level_3_lighting_90_1_2019,ASHRAE 62.1-2019,level_3_ventilation_90_1_2019 +2,90.1-2004,ASHRAE 90.1-2004,level_3_lighting_90_1_2004,ASHRAE 62.1-2004,level_3_ventilation_90_1_2004 diff --git a/data/openstudio_standards_data/initial_data/support_ventilation_space_type_name_tags.csv b/data/openstudio_standards_data/initial_data/support_ventilation_space_type_name_tags.csv new file mode 100644 index 0000000000..071f84481d --- /dev/null +++ b/data/openstudio_standards_data/initial_data/support_ventilation_space_type_name_tags.csv @@ -0,0 +1,111 @@ +ventilation_space_type_name +correctional_facilities_cell +correctional_facilities_dayroom +correctional_facilities_guard_stations +correctional_facilities_booking_waiting +educational_facilities_daycare +educational_facilities_classroom_young +educational_facilities_classroom_old +educational_facilities_lecture_classroom +educational_facilities_lecture_hall +educational_facilities_art_classroom +educational_facilities_science_laboratories +educational_facilities_wood_metal_shop +educational_facilities_computer_lab +educational_facilities_media_center +educational_facilities_music_theater_dance +educational_facilities_multiuse_assembly +educational_facilities_daycare_sickroom +educational_facilities_libraries +educational_facilities_university_college_laboratories +food_beverage_service_restaurant_dining_rooms +food_beverage_service_cafeteria_fast_food_dining +food_beverage_service_bars_cocktail_lounges +food_beverage_service_kitchen +general_conference_meeting +general_conference_corridors +general_conference_storage_rooms +general_break_rooms +general_coffee_stations +hotels_motels_resorts_dormitories_bedroom_living_room +hotels_motels_resorts_dormitories_barracks_sleeping_areas +hotels_motels_resorts_dormitories_lobbies_prefunction +hotels_motels_resorts_dormitories_multi_purpose_assembly +hotels_motels_resorts_dormitories_laundry_rooms +hotels_motels_resorts_dormitories_laundry_rooms_w_dwelling_units +office_buildings_office_space +office_buildings_reception_areas +office_buildings_telephone_data_entry +office_buildings_main_entry_lobbies +office_buildings_breakrooms +office_buildings_occupiable_storage_rooms +miscellaneous_spaces_bank_ vaults_safe_deposit +miscellaneous_spaces_computer +miscellaneous_spaces_pharmacy +miscellaneous_spaces_photo_studios +miscellaneous_spaces_shipping_receiving +miscellaneous_spaces_transportation_waiting +miscellaneous_spaces_warehouses +miscellaneous_spaces_banks_bank_lobbies +miscellaneous_spaces_freezer_refrigerated_spaces +miscellaneous_spaces_manufacturing_wo_hazardous_materials +miscellaneous_spaces_manufacturing_w_hazardous_materials +miscellaneous_spaces_sorting_packing_light_assembly +miscellaneous_spaces_telephone_closets +public_assembly_spaces_auditorium_seating_area +public_assembly_spaces_religious_workshop +public_assembly_spaces_courtrooms +public_assembly_spaces_legislative_chambers +public_assembly_spaces_libraries +public_assembly_spaces_lobbies +public_assembly_spaces_children_museums +public_assembly_spaces_museums_galleries +retail_sales +retail_mall_common_areas +retail_barbershop +retail_beauty_nail_salons +retail_pet_shops +retail_supermarket +retail_coin_operated_laundries +sports_entertainment_sports_arena +sports_entertainment_gym_stadium +sports_entertainment_spectator_areas +sports_entertainment_swimming +sports_entertainment_disco_dance_floors +sports_entertainment_health_club_aerobics_room +sports_entertainment_health_club_weight_rooms +sports_entertainment_bowling_alley +sports_entertainment_gambling_casinos +sports_entertainment_game_arcades +sports_entertainment_stages_studios +animal_facilities_animal_exam_room +animal_facilities_animal_imaging +animal_facilities_animal_operating_rooms +animal_facilities_animal_postoperative_recovery_room +animal_facilities_animal_preparation_rooms +animal_facilities_animal_procedure_room +animal_facilities_animal_surgery_scrub +animal_facilities_large_animal_holding_room +animal_facilities_necropsy +animal_facilities_small_animal_cage_room_static +animal_facilities_small_animal_cage_room_ventilated +outpatient_health_care_facilities_birthing_room +outpatient_health_care_facilities_class_1_imaging_rooms +outpatient_health_care_facilities_dental_operatory +outpatient_health_care_facilities_general_examination_room +outpatient_health_care_facilities_other_dental_treatment_areas +outpatient_health_care_facilities_physical_therapy_exercise_area +outpatient_health_care_facilities_physical_therapy_individual_room +outpatient_health_care_facilities_physical_therapeutic_pool_area +outpatient_health_care_facilities_prosthetics_orthotics_room +outpatient_health_care_facilities_psychiatric_consultation_room +outpatient_health_care_facilities_psychiatric_examination_room +outpatient_health_care_facilities_psychiatric_group_room +outpatient_health_care_facilities_psychiatric_seclusion_room +outpatient_health_care_facilities_speech_therapy_room +outpatient_health_care_facilities_urgent_care_examination_room +outpatient_health_care_facilities_urgent_care_observation_room +outpatient_health_care_facilities_urgent_care_treatment_room +outpatient_health_care_facilities_urgent_care_triage_room +transient_residential_common_corridors +transient_residential_dwelling_unit diff --git a/data/openstudio_standards_data/initial_data/system_requirement_economizer_90_1.csv b/data/openstudio_standards_data/initial_data/system_requirement_economizer_90_1.csv new file mode 100644 index 0000000000..1405f86a9d --- /dev/null +++ b/data/openstudio_standards_data/initial_data/system_requirement_economizer_90_1.csv @@ -0,0 +1,497 @@ +template,climate_zone,data_center,capacity_limit,fixed_dry_bulb_high_limit_shutoff_temp,annotation +90.1-2004,ASHRAE 169-2006-1A,FALSE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-1A,TRUE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-1B,FALSE,,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-1B,TRUE,,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-2A,FALSE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-2A,TRUE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-2B,FALSE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-2B,TRUE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-3A,FALSE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-3A,TRUE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-3B,FALSE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-3B,TRUE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-3C,FALSE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-3C,TRUE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-4A,FALSE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-4A,TRUE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-4B,FALSE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-4B,TRUE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-4C,FALSE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-4C,TRUE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-5A,FALSE,135000,70,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-5A,TRUE,135000,70,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-5B,FALSE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-5B,TRUE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-5C,FALSE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-5C,TRUE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-6A,FALSE,135000,70,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-6A,TRUE,135000,70,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-6B,FALSE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-6B,TRUE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-7A,FALSE,135000,70,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-7A,TRUE,135000,70,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-7B,FALSE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-7B,TRUE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-8A,FALSE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-8A,TRUE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-8B,FALSE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-8B,TRUE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-1A,FALSE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-1A,TRUE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-1B,FALSE,,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-1B,TRUE,,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-2A,FALSE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-2A,TRUE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-2B,FALSE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-2B,TRUE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-3A,FALSE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-3A,TRUE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-3B,FALSE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-3B,TRUE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-3C,FALSE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-3C,TRUE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-4A,FALSE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-4A,TRUE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-4B,FALSE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-4B,TRUE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-4C,FALSE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-4C,TRUE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-5A,FALSE,135000,70,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-5A,TRUE,135000,70,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-5B,FALSE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-5B,TRUE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-5C,FALSE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-5C,TRUE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-6A,FALSE,135000,70,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-6A,TRUE,135000,70,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-6B,FALSE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-6B,TRUE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-7A,FALSE,135000,70,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-7A,TRUE,135000,70,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-7B,FALSE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-7B,TRUE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-8A,FALSE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-8A,TRUE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-8B,FALSE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-8B,TRUE,135000,75,90.1-2004 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-1A,FALSE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-1A,TRUE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-1B,FALSE,,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-1B,TRUE,,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-2A,FALSE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-2A,TRUE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-2B,FALSE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-2B,TRUE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-3A,FALSE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-3A,TRUE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-3B,FALSE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-3B,TRUE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-3C,FALSE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-3C,TRUE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-4A,FALSE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-4A,TRUE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-4B,FALSE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-4B,TRUE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-4C,FALSE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-4C,TRUE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-5A,FALSE,135000,70,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-5A,TRUE,135000,70,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-5B,FALSE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-5B,TRUE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-5C,FALSE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-5C,TRUE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-6A,FALSE,135000,70,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-6A,TRUE,135000,70,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-6B,FALSE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-6B,TRUE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-7A,FALSE,135000,70,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-7A,TRUE,135000,70,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-7B,FALSE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-7B,TRUE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-8A,FALSE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-8A,TRUE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-8B,FALSE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-8B,TRUE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-1A,FALSE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-1A,TRUE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-1B,FALSE,,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-1B,TRUE,,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-2A,FALSE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-2A,TRUE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-2B,FALSE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-2B,TRUE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-3A,FALSE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-3A,TRUE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-3B,FALSE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-3B,TRUE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-3C,FALSE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-3C,TRUE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-4A,FALSE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-4A,TRUE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-4B,FALSE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-4B,TRUE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-4C,FALSE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-4C,TRUE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-5A,FALSE,135000,70,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-5A,TRUE,135000,70,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-5B,FALSE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-5B,TRUE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-5C,FALSE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-5C,TRUE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-6A,FALSE,135000,70,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-6A,TRUE,135000,70,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-6B,FALSE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-6B,TRUE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-7A,FALSE,135000,70,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-7A,TRUE,135000,70,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-7B,FALSE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-7B,TRUE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-8A,FALSE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-8A,TRUE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-8B,FALSE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-8B,TRUE,135000,75,90.1-2007 Table 6.5.1 +90.1-2010,ASHRAE 169-2006-1A,TRUE,,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-1A,FALSE,,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-1B,TRUE,,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-1B,FALSE,,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-2A,TRUE,,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-2A,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-2B,TRUE,135000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-2B,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-3A,TRUE,,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-3A,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-3B,TRUE,65000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-3B,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-3C,TRUE,65000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-3C,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-4A,TRUE,,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-4A,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-4B,TRUE,65000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-4B,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-4C,TRUE,65000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-4C,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-5A,TRUE,135000,70,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-5A,FALSE,54000,70,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-5B,TRUE,65000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-5B,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-5C,TRUE,65000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-5C,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-6A,TRUE,135000,70,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-6A,FALSE,54000,70,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-6B,TRUE,65000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-6B,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-7A,TRUE,135000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-7A,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-7B,TRUE,135000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-7B,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-8A,TRUE,135000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-8A,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-8B,TRUE,135000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-8B,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-1A,TRUE,,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-1A,FALSE,,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-1B,TRUE,,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-1B,FALSE,,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-2A,TRUE,,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-2A,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-2B,TRUE,135000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-2B,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-3A,TRUE,,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-3A,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-3B,TRUE,65000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-3B,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-3C,TRUE,65000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-3C,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-4A,TRUE,,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-4A,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-4B,TRUE,65000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-4B,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-4C,TRUE,65000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-4C,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-5A,TRUE,135000,70,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-5A,FALSE,54000,70,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-5B,TRUE,65000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-5B,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-5C,TRUE,65000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-5C,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-6A,TRUE,135000,70,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-6A,FALSE,54000,70,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-6B,TRUE,65000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-6B,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-7A,TRUE,135000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-7A,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-7B,TRUE,135000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-7B,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-8A,TRUE,135000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-8A,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-8B,TRUE,135000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-8B,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2013,ASHRAE 169-2006-1A,TRUE,,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-1A,FALSE,,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-1B,TRUE,,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-1B,FALSE,,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-2A,TRUE,,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-2A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-2B,TRUE,135000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-2B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-3A,TRUE,,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-3A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-3B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-3B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-3C,TRUE,65000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-3C,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-4A,TRUE,,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-4A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-4B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-4B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-4C,TRUE,65000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-4C,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-5A,TRUE,135000,70,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-5A,FALSE,54000,70,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-5B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-5B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-5C,TRUE,65000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-5C,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-6A,TRUE,135000,70,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-6A,FALSE,54000,70,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-6B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-6B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-7A,TRUE,135000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-7A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-7B,TRUE,135000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-7B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-8A,TRUE,135000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-8A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-8B,TRUE,135000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-8B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-1A,TRUE,,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-1A,FALSE,,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-1B,TRUE,,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-1B,FALSE,,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-2A,TRUE,,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-2A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-2B,TRUE,135000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-2B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-3A,TRUE,,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-3A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-3B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-3B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-3C,TRUE,65000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-3C,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-4A,TRUE,,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-4A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-4B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-4B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-4C,TRUE,65000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-4C,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-5A,TRUE,135000,70,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-5A,FALSE,54000,70,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-5B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-5B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-5C,TRUE,65000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-5C,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-6A,TRUE,135000,70,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-6A,FALSE,54000,70,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-6B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-6B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-7A,TRUE,135000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-7A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-7B,TRUE,135000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-7B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-8A,TRUE,135000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-8A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-8B,TRUE,135000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-8B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2004,ASHRAE 169-2006-0A,FALSE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-0B,FALSE,,75,90.1-2004 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-0A,FALSE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-0B,FALSE,,75,90.1-2007 Table 6.5.1 +90.1-2010,ASHRAE 169-2006-0A,FALSE,,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-0B,FALSE,,75,90.1-2010 Table 6.5.1A +90.1-2013,ASHRAE 169-2006-0A,FALSE,,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-0B,FALSE,,75,90.1-2013 Table 6.5.1-1 +90.1-2004,ASHRAE 169-2013-0A,FALSE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-0B,FALSE,,75,90.1-2004 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-0A,FALSE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-0B,FALSE,,75,90.1-2007 Table 6.5.1 +90.1-2010,ASHRAE 169-2013-0A,FALSE,,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-0B,FALSE,,75,90.1-2010 Table 6.5.1A +90.1-2013,ASHRAE 169-2013-0A,FALSE,,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-0B,FALSE,,75,90.1-2013 Table 6.5.1-1 +90.1-2010,ASHRAE 169-2006-0A,TRUE,,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-0B,TRUE,,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-0A,TRUE,,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-0B,TRUE,,75,90.1-2010 Table 6.5.1B +90.1-2013,ASHRAE 169-2006-0A,TRUE,,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-0B,TRUE,,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-0A,TRUE,,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-0B,TRUE,,75,90.1-2013 Table 6.5.1-2 +90.1-2016,ASHRAE 169-2006-1A,TRUE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-1A,FALSE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-1B,TRUE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-1B,FALSE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-2A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-2A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-2B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-2B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-3A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-3A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-3B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-3B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-3C,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-3C,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-4A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-4A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-4B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-4B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-4C,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-4C,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-5A,TRUE,54000,70,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-5A,FALSE,54000,70,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-5B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-5B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-5C,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-5C,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-6A,TRUE,54000,70,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-6A,FALSE,54000,70,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-6B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-6B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-7A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-7A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-7B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-7B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-8A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-8A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-8B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-8B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-1A,TRUE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-1A,FALSE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-1B,TRUE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-1B,FALSE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-2A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-2A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-2B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-2B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-3A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-3A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-3B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-3B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-3C,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-3C,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-4A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-4A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-4B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-4B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-4C,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-4C,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-5A,TRUE,54000,70,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-5A,FALSE,54000,70,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-5B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-5B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-5C,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-5C,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-6A,TRUE,54000,70,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-6A,FALSE,54000,70,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-6B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-6B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-7A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-7A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-7B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-7B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-8A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-8A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-8B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-8B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-0A,FALSE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-0B,FALSE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-0A,FALSE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-0B,FALSE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-0A,TRUE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-0B,TRUE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-0A,TRUE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-0B,TRUE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-1A,TRUE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-1A,FALSE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-1B,TRUE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-1B,FALSE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-2A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-2A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-2B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-2B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-3A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-3A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-3B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-3B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-3C,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-3C,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-4A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-4A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-4B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-4B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-4C,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-4C,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-5A,TRUE,54000,70,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-5A,FALSE,54000,70,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-5B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-5B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-5C,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-5C,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-6A,TRUE,54000,70,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-6A,FALSE,54000,70,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-6B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-6B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-7A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-7A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-7B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-7B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-8A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-8A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-8B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-8B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-1A,TRUE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-1A,FALSE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-1B,TRUE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-1B,FALSE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-2A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-2A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-2B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-2B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-3A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-3A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-3B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-3B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-3C,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-3C,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-4A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-4A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-4B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-4B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-4C,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-4C,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-5A,TRUE,54000,70,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-5A,FALSE,54000,70,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-5B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-5B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-5C,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-5C,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-6A,TRUE,54000,70,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-6A,FALSE,54000,70,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-6B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-6B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-7A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-7A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-7B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-7B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-8A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-8A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-8B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-8B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-0A,FALSE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-0B,FALSE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-0A,FALSE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-0B,FALSE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-0A,TRUE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-0B,TRUE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-0A,TRUE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-0B,TRUE,,75,90.1-2019 Table 6.5.1.1.3 diff --git a/data/openstudio_standards_data/initial_data/system_requirement_energy_recovery_90_1.csv b/data/openstudio_standards_data/initial_data/system_requirement_energy_recovery_90_1.csv new file mode 100644 index 0000000000..a06d3844d7 --- /dev/null +++ b/data/openstudio_standards_data/initial_data/system_requirement_energy_recovery_90_1.csv @@ -0,0 +1,409 @@ +template,climate_zone,under_8000_hours,nontransient_dwelling,percent_oa_0_to_10,percent_oa_10_to_20,percent_oa_20_to_30,percent_oa_30_to_40,percent_oa_40_to_50,percent_oa_50_to_60,percent_oa_60_to_70,percent_oa_70_to_80,percent_oa_greater_than_80,enthalpy_recovery_ratio_design_conditions,enthalpy_recovery_ratio,annotation +90.1-2010,ASHRAE 169-2006-1A,,,,,,5500,4500,3500,2000,1000,0,, +90.1-2010,ASHRAE 169-2006-1B,,,,,,,,26000,12000,5000,4000,, +90.1-2010,ASHRAE 169-2006-2A,,,,,,5500,4500,3500,2000,1000,0,, +90.1-2010,ASHRAE 169-2006-2B,,,,,,,,26000,12000,5000,4000,, +90.1-2010,ASHRAE 169-2006-3A,,,,,,5500,4500,3500,2000,1000,0,, +90.1-2010,ASHRAE 169-2006-3B,,,,,,,,,,5000,5000,, +90.1-2010,ASHRAE 169-2006-3C,,,,,,,,,,5000,5000,, +90.1-2010,ASHRAE 169-2006-4A,,,,,,5500,4500,3500,2000,1000,0,, +90.1-2010,ASHRAE 169-2006-4B,,,,,,,,,,5000,5000,, +90.1-2010,ASHRAE 169-2006-4C,,,,,,,,,,5000,5000,, +90.1-2010,ASHRAE 169-2006-5A,,,,,,5500,4500,3500,2000,1000,0,, +90.1-2010,ASHRAE 169-2006-5B,,,,,,,,,,5000,5000,, +90.1-2010,ASHRAE 169-2006-5C,,,,,,,,26000,12000,5000,4000,, +90.1-2010,ASHRAE 169-2006-6A,,,,,,5500,4500,3500,2000,1000,0,, +90.1-2010,ASHRAE 169-2006-6B,,,,,,11000,5500,4500,3500,2500,1500,, +90.1-2010,ASHRAE 169-2006-7A,,,,,,2500,1000,0,0,0,0,, +90.1-2010,ASHRAE 169-2006-7B,,,,,,2500,1000,0,0,0,0,, +90.1-2010,ASHRAE 169-2006-8A,,,,,,2500,1000,0,0,0,0,, +90.1-2010,ASHRAE 169-2006-8B,,,,,,2500,1000,0,0,0,0,, +90.1-2010,ASHRAE 169-2013-1A,,,,,,5500,4500,3500,2000,1000,0,, +90.1-2010,ASHRAE 169-2013-1B,,,,,,,,26000,12000,5000,4000,, +90.1-2010,ASHRAE 169-2013-2A,,,,,,5500,4500,3500,2000,1000,0,, +90.1-2010,ASHRAE 169-2013-2B,,,,,,,,26000,12000,5000,4000,, +90.1-2010,ASHRAE 169-2013-3A,,,,,,5500,4500,3500,2000,1000,0,, +90.1-2010,ASHRAE 169-2013-3B,,,,,,,,,,5000,5000,, +90.1-2010,ASHRAE 169-2013-3C,,,,,,,,,,5000,5000,, +90.1-2010,ASHRAE 169-2013-4A,,,,,,5500,4500,3500,2000,1000,0,, +90.1-2010,ASHRAE 169-2013-4B,,,,,,,,,,5000,5000,, +90.1-2010,ASHRAE 169-2013-4C,,,,,,,,,,5000,5000,, +90.1-2010,ASHRAE 169-2013-5A,,,,,,5500,4500,3500,2000,1000,0,, +90.1-2010,ASHRAE 169-2013-5B,,,,,,,,,,5000,5000,, +90.1-2010,ASHRAE 169-2013-5C,,,,,,,,26000,12000,5000,4000,, +90.1-2010,ASHRAE 169-2013-6A,,,,,,5500,4500,3500,2000,1000,0,, +90.1-2010,ASHRAE 169-2013-6B,,,,,,11000,5500,4500,3500,2500,1500,, +90.1-2010,ASHRAE 169-2013-7A,,,,,,2500,1000,0,0,0,0,, +90.1-2010,ASHRAE 169-2013-7B,,,,,,2500,1000,0,0,0,0,, +90.1-2010,ASHRAE 169-2013-8A,,,,,,2500,1000,0,0,0,0,, +90.1-2010,ASHRAE 169-2013-8B,,,,,,2500,1000,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-1A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, +90.1-2013,ASHRAE 169-2006-1A,FALSE,,,2500,2000,1000,500,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-1B,TRUE,,,,,,,26000,12000,5000,4000,, +90.1-2013,ASHRAE 169-2006-1B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, +90.1-2013,ASHRAE 169-2006-2A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, +90.1-2013,ASHRAE 169-2006-2A,FALSE,,,2500,2000,1000,500,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-2B,TRUE,,,,,,,26000,12000,5000,4000,, +90.1-2013,ASHRAE 169-2006-2B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, +90.1-2013,ASHRAE 169-2006-3A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, +90.1-2013,ASHRAE 169-2006-3A,FALSE,,,2500,2000,1000,500,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-3B,TRUE,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2006-3B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, +90.1-2013,ASHRAE 169-2006-3C,TRUE,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2006-3C,FALSE,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2006-4A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, +90.1-2013,ASHRAE 169-2006-4A,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-4B,TRUE,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2006-4B,FALSE,,,2500,2000,1000,500,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-4C,TRUE,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2006-4C,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, +90.1-2013,ASHRAE 169-2006-5A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, +90.1-2013,ASHRAE 169-2006-5A,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-5B,TRUE,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2006-5B,FALSE,,,2500,2000,1000,500,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-5C,TRUE,,,,,,,26000,12000,5000,4000,, +90.1-2013,ASHRAE 169-2006-5C,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, +90.1-2013,ASHRAE 169-2006-6A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, +90.1-2013,ASHRAE 169-2006-6A,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-6B,TRUE,,,28000,26500,11000,5500,4500,3500,2500,1500,, +90.1-2013,ASHRAE 169-2006-6B,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-7A,TRUE,,,4500,4000,2500,1000,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-7A,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-7B,TRUE,,,4500,4000,2500,1000,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-7B,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-8A,TRUE,,,4500,4000,2500,1000,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-8A,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-8B,TRUE,,,4500,4000,2500,1000,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-8B,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-1A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, +90.1-2013,ASHRAE 169-2013-1A,FALSE,,,2500,2000,1000,500,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-1B,TRUE,,,,,,,26000,12000,5000,4000,, +90.1-2013,ASHRAE 169-2013-1B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, +90.1-2013,ASHRAE 169-2013-2A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, +90.1-2013,ASHRAE 169-2013-2A,FALSE,,,2500,2000,1000,500,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-2B,TRUE,,,,,,,26000,12000,5000,4000,, +90.1-2013,ASHRAE 169-2013-2B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, +90.1-2013,ASHRAE 169-2013-3A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, +90.1-2013,ASHRAE 169-2013-3A,FALSE,,,2500,2000,1000,500,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-3B,TRUE,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2013-3B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, +90.1-2013,ASHRAE 169-2013-3C,TRUE,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2013-3C,FALSE,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2013-4A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, +90.1-2013,ASHRAE 169-2013-4A,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-4B,TRUE,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2013-4B,FALSE,,,2500,2000,1000,500,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-4C,TRUE,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2013-4C,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, +90.1-2013,ASHRAE 169-2013-5A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, +90.1-2013,ASHRAE 169-2013-5A,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-5B,TRUE,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2013-5B,FALSE,,,2500,2000,1000,500,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-5C,TRUE,,,,,,,26000,12000,5000,4000,, +90.1-2013,ASHRAE 169-2013-5C,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, +90.1-2013,ASHRAE 169-2013-6A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, +90.1-2013,ASHRAE 169-2013-6A,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-6B,TRUE,,,28000,26500,11000,5500,4500,3500,2500,1500,, +90.1-2013,ASHRAE 169-2013-6B,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-7A,TRUE,,,4500,4000,2500,1000,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-7A,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-7B,TRUE,,,4500,4000,2500,1000,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-7B,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-8A,TRUE,,,4500,4000,2500,1000,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-8A,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-8B,TRUE,,,4500,4000,2500,1000,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-8B,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2016,ASHRAE 169-2006-1A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-1A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-1B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-1B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-2A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-2A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-2B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-2B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-3A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-3A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-3B,TRUE,,,,,,,,,,,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-3B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-3C,TRUE,,,,,,,,,,,Heating,0.5 +90.1-2016,ASHRAE 169-2006-3C,FALSE,,,,,,,,,,,Heating,0.5 +90.1-2016,ASHRAE 169-2006-4A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-4A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-4B,TRUE,,,,,,,,,,,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-4B,TRUE,,,,,,,,,,,Heating,0.5 +90.1-2016,ASHRAE 169-2006-4B,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-4B,FALSE,,,2500,2000,1000,500,140,120,100,80,Heating,0.5 +90.1-2016,ASHRAE 169-2006-4C,TRUE,,,,,,,,,,,Heating,0.5 +90.1-2016,ASHRAE 169-2006-4C,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 +90.1-2016,ASHRAE 169-2006-5A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-5A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-5B,TRUE,,,,,,,,,,,Heating,0.5 +90.1-2016,ASHRAE 169-2006-5B,FALSE,,,2500,2000,1000,500,140,120,100,80,Heating,0.5 +90.1-2016,ASHRAE 169-2006-5C,TRUE,,,,,,,26000,12000,5000,4000,Heating,0.5 +90.1-2016,ASHRAE 169-2006-5C,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 +90.1-2016,ASHRAE 169-2006-6A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-6A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-6B,TRUE,,,28000,26500,11000,5500,4500,3500,2500,1500,Heating,0.5 +90.1-2016,ASHRAE 169-2006-6B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2016,ASHRAE 169-2006-7A,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2016,ASHRAE 169-2006-7A,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2016,ASHRAE 169-2006-7B,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2016,ASHRAE 169-2006-7B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2016,ASHRAE 169-2006-8A,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2016,ASHRAE 169-2006-8A,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2016,ASHRAE 169-2006-8B,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2016,ASHRAE 169-2006-8B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2016,ASHRAE 169-2013-1A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-1A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-1B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-1B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-2A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-2A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-2B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-2B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-3A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-3A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-3B,TRUE,,,,,,,,,,,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-3B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-3C,TRUE,,,,,,,,,,,Heating,0.5 +90.1-2016,ASHRAE 169-2013-3C,FALSE,,,,,,,,,,,Heating,0.5 +90.1-2016,ASHRAE 169-2013-4A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-4A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-4B,TRUE,,,,,,,,,,,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-4B,TRUE,,,,,,,,,,,Heating,0.5 +90.1-2016,ASHRAE 169-2013-4B,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-4B,FALSE,,,2500,2000,1000,500,140,120,100,80,Heating,0.5 +90.1-2016,ASHRAE 169-2013-4C,TRUE,,,,,,,,,,,Heating,0.5 +90.1-2016,ASHRAE 169-2013-4C,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 +90.1-2016,ASHRAE 169-2013-5A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-5A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-5B,TRUE,,,,,,,,,,,Heating,0.5 +90.1-2016,ASHRAE 169-2013-5B,FALSE,,,2500,2000,1000,500,140,120,100,80,Heating,0.5 +90.1-2016,ASHRAE 169-2013-5C,TRUE,,,,,,,26000,12000,5000,4000,Heating,0.5 +90.1-2016,ASHRAE 169-2013-5C,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 +90.1-2016,ASHRAE 169-2013-6A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-6A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-6B,TRUE,,,28000,26500,11000,5500,4500,3500,2500,1500,Heating,0.5 +90.1-2016,ASHRAE 169-2013-6B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2016,ASHRAE 169-2013-7A,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2016,ASHRAE 169-2013-7A,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2016,ASHRAE 169-2013-7B,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2016,ASHRAE 169-2013-7B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2016,ASHRAE 169-2013-8A,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2016,ASHRAE 169-2013-8A,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2016,ASHRAE 169-2013-8B,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2016,ASHRAE 169-2013-8B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2006-1A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-1A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-1A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-1A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-1B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-1B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-1B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-1B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-2A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-2A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-2A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-2A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-2B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-2B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-2B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-2B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-3A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-3A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-3A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 +90.1-2019,ASHRAE 169-2006-3A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-3A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-3A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5 +90.1-2019,ASHRAE 169-2006-3B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-3B,TRUE,FALSE,,,,,,,,,,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-3B,TRUE,FALSE,,,,,,,,,,Heating,0.5 +90.1-2019,ASHRAE 169-2006-3B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-3B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-3B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 +90.1-2019,ASHRAE 169-2006-3C,TRUE,TRUE,,,,,,,,,,, +90.1-2019,ASHRAE 169-2006-3C,TRUE,FALSE,,,,,,,,,,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-3C,TRUE,FALSE,,,,,,,,,,Heating,0.5 +90.1-2019,ASHRAE 169-2006-3C,FALSE,TRUE,,,,,,,,,,, +90.1-2019,ASHRAE 169-2006-3C,FALSE,FALSE,,,,,,,,,,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-3C,FALSE,FALSE,,,,,,,,,,Heating,0.5 +90.1-2019,ASHRAE 169-2006-4A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-4A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-4A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 +90.1-2019,ASHRAE 169-2006-4A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-4A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-4A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2006-4B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-4B,TRUE,FALSE,,,,,,,,,,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-4B,TRUE,FALSE,,,,,,,,,,Heating,0.5 +90.1-2019,ASHRAE 169-2006-4B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-4B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-4B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5 +90.1-2019,ASHRAE 169-2006-4C,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-4C,TRUE,FALSE,,,,,,,,,,Heating,0.5 +90.1-2019,ASHRAE 169-2006-4C,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-4C,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 +90.1-2019,ASHRAE 169-2006-5A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-5A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-5A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 +90.1-2019,ASHRAE 169-2006-5A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-5A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-5A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2006-5B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-5B,TRUE,FALSE,,,,,,,,,,Heating,0.5 +90.1-2019,ASHRAE 169-2006-5B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-5B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5 +90.1-2019,ASHRAE 169-2006-5C,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-5C,TRUE,FALSE,,,,,,26000,12000,5000,4000,Heating,0.5 +90.1-2019,ASHRAE 169-2006-5C,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-5C,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 +90.1-2019,ASHRAE 169-2006-6A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-6A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-6A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 +90.1-2019,ASHRAE 169-2006-6A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-6A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-6A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2006-6B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-6B,TRUE,FALSE,,28000,26500,11000,5500,4500,3500,2500,1500,Heating,0.5 +90.1-2019,ASHRAE 169-2006-6B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-6B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2006-7A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-7A,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2019,ASHRAE 169-2006-7A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-7A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2006-7B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-7B,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2019,ASHRAE 169-2006-7B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-7B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2006-8A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-8A,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2019,ASHRAE 169-2006-8A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-8A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2006-8B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-8B,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2019,ASHRAE 169-2006-8B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-8B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2013-1A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-1A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-1A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-1A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-1B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-1B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-1B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-1B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-2A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-2A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-2A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-2A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-2B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-2B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-2B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-2B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-3A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-3A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-3A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 +90.1-2019,ASHRAE 169-2013-3A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-3A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-3A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5 +90.1-2019,ASHRAE 169-2013-3B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-3B,TRUE,FALSE,,,,,,,,,,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-3B,TRUE,FALSE,,,,,,,,,,Heating,0.5 +90.1-2019,ASHRAE 169-2013-3B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-3B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-3B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 +90.1-2019,ASHRAE 169-2013-3C,TRUE,TRUE,,,,,,,,,,, +90.1-2019,ASHRAE 169-2013-3C,TRUE,FALSE,,,,,,,,,,Heating,0.5 +90.1-2019,ASHRAE 169-2013-3C,FALSE,TRUE,,,,,,,,,,, +90.1-2019,ASHRAE 169-2013-3C,FALSE,FALSE,,,,,,,,,,Heating,0.5 +90.1-2019,ASHRAE 169-2013-4A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-4A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-4A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 +90.1-2019,ASHRAE 169-2013-4A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-4A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-4A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2013-4B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-4B,TRUE,FALSE,,,,,,,,,,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-4B,TRUE,FALSE,,,,,,,,,,Heating,0.5 +90.1-2019,ASHRAE 169-2013-4B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-4B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-4B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5 +90.1-2019,ASHRAE 169-2013-4C,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-4C,TRUE,FALSE,,,,,,,,,,Heating,0.5 +90.1-2019,ASHRAE 169-2013-4C,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-4C,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 +90.1-2019,ASHRAE 169-2013-5A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-5A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-5A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 +90.1-2019,ASHRAE 169-2013-5A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-5A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-5A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2013-5B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-5B,TRUE,FALSE,,,,,,,,,,Heating,0.5 +90.1-2019,ASHRAE 169-2013-5B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-5B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5 +90.1-2019,ASHRAE 169-2013-5C,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-5C,TRUE,FALSE,,,,,,26000,12000,5000,4000,Heating,0.5 +90.1-2019,ASHRAE 169-2013-5C,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-5C,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 +90.1-2019,ASHRAE 169-2013-6A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-6A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-6A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 +90.1-2019,ASHRAE 169-2013-6A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-6A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-6A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2013-6B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-6B,TRUE,FALSE,,28000,26500,11000,5500,4500,3500,2500,1500,Heating,0.5 +90.1-2019,ASHRAE 169-2013-6B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-6B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2013-7A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-7A,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2019,ASHRAE 169-2013-7A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-7A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2013-7B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-7B,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2019,ASHRAE 169-2013-7B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-7B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2013-8A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-8A,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2019,ASHRAE 169-2013-8A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-8A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2013-8B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-8B,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2019,ASHRAE 169-2013-8B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-8B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2010,ASHRAE 169-2006-0A,,,,,,5500,4500,3500,2000,1000,0,, +90.1-2010,ASHRAE 169-2006-0B,,,,,,,,26000,12000,5000,4000,, +90.1-2010,ASHRAE 169-2013-0A,,,,,,5500,4500,3500,2000,1000,0,, +90.1-2010,ASHRAE 169-2013-0B,,,,,,,,26000,12000,5000,4000,, +90.1-2013,ASHRAE 169-2006-0A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, +90.1-2013,ASHRAE 169-2006-0A,FALSE,,,2500,2000,1000,500,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-0B,TRUE,,,,,,,26000,12000,5000,4000,, +90.1-2013,ASHRAE 169-2006-0B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, +90.1-2013,ASHRAE 169-2013-0A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, +90.1-2013,ASHRAE 169-2013-0A,FALSE,,,2500,2000,1000,500,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-0B,TRUE,,,,,,,26000,12000,5000,4000,, +90.1-2013,ASHRAE 169-2013-0B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, +90.1-2016,ASHRAE 169-2006-0A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-0A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-0B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-0B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-0A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-0A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-0B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-0B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-0A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-0A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-0A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-0A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-0B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-0B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-0B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-0B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-0A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-0A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-0A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-0A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-0B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-0B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-0B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-0B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 diff --git a/data/openstudio_standards_data/initial_data/vent_def_62_1_2004.json b/data/openstudio_standards_data/initial_data/vent_def_62_1_2004.json new file mode 100644 index 0000000000..8571539cb4 --- /dev/null +++ b/data/openstudio_standards_data/initial_data/vent_def_62_1_2004.json @@ -0,0 +1,884 @@ +[ + { + "id": 1, + "ventilation_primary_space_type": "Correctional Facilities", + "ventilation_secondary_space_type": "Cell", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 2, + "ventilation_primary_space_type": "Correctional Facilities", + "ventilation_secondary_space_type": "Day room", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 30, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 3, + "ventilation_primary_space_type": "Correctional Facilities", + "ventilation_secondary_space_type": "Guard stations", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 15, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 4, + "ventilation_primary_space_type": "Correctional Facilities", + "ventilation_secondary_space_type": "Booking/waiting", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 50, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 5, + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Daycare (through age 4)", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 6, + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Classrooms (ages 5-8)", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 7, + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Classrooms (age 9 plus)", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 35, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 8, + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Lecture classroom", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 65, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 9, + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Lecture hall (fixed seats)", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 150, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 10, + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Art classroom", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 11, + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Science laboratories", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "id": 12, + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Wood/metal shop", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 13, + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Computer lab", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 14, + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Media center", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 15, + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Music/theater/dance", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 35, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 16, + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Multi-use assembly", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 17, + "ventilation_primary_space_type": "Food and Beverage Service", + "ventilation_secondary_space_type": "Restaurant dining rooms", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 70, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 18, + "ventilation_primary_space_type": "Food and Beverage Service", + "ventilation_secondary_space_type": "Cafeteria/fast food dining", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 19, + "ventilation_primary_space_type": "Food and Beverage Service", + "ventilation_secondary_space_type": "Bars, cocktail lounges", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 20, + "ventilation_primary_space_type": "General", + "ventilation_secondary_space_type": "Conference/meeting", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 50, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 21, + "ventilation_primary_space_type": "General", + "ventilation_secondary_space_type": "Corridors", + "ventilation_per_person": null, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": null, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 22, + "ventilation_primary_space_type": "General", + "ventilation_secondary_space_type": "Storage rooms", + "ventilation_per_person": null, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": null, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 23, + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Bedroom/living Room", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 24, + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Barracks sleeping areas", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 25, + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Lobbies/prefunction", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 30, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 26, + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Multi-purpose assembly", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 120, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 27, + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Office space", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 5, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 28, + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Reception areas", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 29, + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Telephone/data entry", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 60, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 30, + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Main entry lobbies", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 31, + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Bank vaults/safe deposit", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 5, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 32, + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Computer (not printing)", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 4, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 33, + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Pharmacy (prep. area)", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 34, + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Photo studios", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 35, + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Shipping/receiving", + "ventilation_per_person": null, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": null, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 36, + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Transportation waiting", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 37, + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Warehouses", + "ventilation_per_person": null, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": null, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 38, + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Auditorium seating area", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 150, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 39, + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Places of religious workshop", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 120, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 40, + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Courtrooms", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 70, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 41, + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Legislative chambers", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 50, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 42, + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Libraries", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 43, + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Lobbies", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 150, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 44, + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Museums (children\u2019s)", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 45, + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Museums/galleries", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 46, + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Sales (except as below)", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 15, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 47, + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Mall common areas", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 48, + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Barber shop", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 49, + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Beauty and nail salons", + "ventilation_per_person": 20, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 50, + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Pet shops (animal areas)", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 51, + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Supermarket", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 8, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 52, + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Coin-operated laundries", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 53, + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Sports arena (play area)", + "ventilation_per_person": null, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.3, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": null, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 54, + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Gym, stadium (play area)", + "ventilation_per_person": null, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.3, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 30, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 55, + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Spectator areas", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 150, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 56, + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Swimming (pool & deck)", + "ventilation_per_person": null, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.48, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": null, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 57, + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Disco/dance floors", + "ventilation_per_person": 20, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 58, + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Health club/aerobics room", + "ventilation_per_person": 20, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 59, + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Health club/weight rooms", + "ventilation_per_person": 20, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 60, + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Bowling alley (seating)", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 61, + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Gambling casinos", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 120, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 62, + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Game arcades", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 63, + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Stages, studios", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 70, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/initial_data/vent_def_62_1_2019.json b/data/openstudio_standards_data/initial_data/vent_def_62_1_2019.json new file mode 100644 index 0000000000..49c385b12b --- /dev/null +++ b/data/openstudio_standards_data/initial_data/vent_def_62_1_2019.json @@ -0,0 +1,1528 @@ +[ + { + "id": 1, + "ventilation_primary_space_type": "Animal Facilities", + "ventilation_secondary_space_type": "Animal exam room (veterinary office)", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 2, + "ventilation_primary_space_type": "Animal Facilities", + "ventilation_secondary_space_type": "Animal imaging (MRI/CT/PET)", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 3, + "os": null, + "annotation": "" + }, + { + "id": 3, + "ventilation_primary_space_type": "Animal Facilities", + "ventilation_secondary_space_type": "Animal operating rooms", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 3, + "os": null, + "annotation": "" + }, + { + "id": 4, + "ventilation_primary_space_type": "Animal Facilities", + "ventilation_secondary_space_type": "Animal postoperative recovery room", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 3, + "os": null, + "annotation": "" + }, + { + "id": 5, + "ventilation_primary_space_type": "Animal Facilities", + "ventilation_secondary_space_type": "Animal preparation rooms", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 3, + "os": null, + "annotation": "" + }, + { + "id": 6, + "ventilation_primary_space_type": "Animal Facilities", + "ventilation_secondary_space_type": "Animal procedure room", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 3, + "os": null, + "annotation": "" + }, + { + "id": 7, + "ventilation_primary_space_type": "Animal Facilities", + "ventilation_secondary_space_type": "Animal surgery scrub", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 3, + "os": null, + "annotation": "" + }, + { + "id": 8, + "ventilation_primary_space_type": "Animal Facilities", + "ventilation_secondary_space_type": "Large-animal holding room", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 3, + "os": null, + "annotation": "" + }, + { + "id": 9, + "ventilation_primary_space_type": "Animal Facilities", + "ventilation_secondary_space_type": "Necropsy", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 3, + "os": null, + "annotation": "" + }, + { + "id": 10, + "ventilation_primary_space_type": "Animal Facilities", + "ventilation_secondary_space_type": "Small-animal-cage room (static cages)", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 3, + "os": null, + "annotation": "" + }, + { + "id": 11, + "ventilation_primary_space_type": "Animal Facilities", + "ventilation_secondary_space_type": "Small-animal-cage room (ventilated cages)", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 3, + "os": null, + "annotation": "" + }, + { + "id": 12, + "ventilation_primary_space_type": "Correctional Facilities", + "ventilation_secondary_space_type": "Booking/waiting", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 50, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 13, + "ventilation_primary_space_type": "Correctional Facilities", + "ventilation_secondary_space_type": "Cell", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 14, + "ventilation_primary_space_type": "Correctional Facilities", + "ventilation_secondary_space_type": "Dayroom", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 30, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 15, + "ventilation_primary_space_type": "Correctional Facilities", + "ventilation_secondary_space_type": "Guard stations", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 15, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 16, + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Art classroom", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 17, + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Classrooms (ages 5 to 8)", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 18, + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Classrooms (age 9 plus)", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 35, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 19, + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Computer lab", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 20, + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Daycare sickroom", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 3, + "os": null, + "annotation": "" + }, + { + "id": 21, + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Daycare (through age 4)", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 22, + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Lecture classroom", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 65, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 23, + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Lecture hall (fixed seats)", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 150, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 24, + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Libraries (education)", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "id": 25, + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Media center", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 26, + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Multiuse assembly", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 27, + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Music/theater/dance", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 35, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 28, + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Science laboratories", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 29, + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "University/college laboratories", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 30, + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Wood/metal shop", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 31, + "ventilation_primary_space_type": "Food and Beverage Service", + "ventilation_secondary_space_type": "Bars, cocktail lounges", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 32, + "ventilation_primary_space_type": "Food and Beverage Service", + "ventilation_secondary_space_type": "Cafeteria/fast-food dining", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 33, + "ventilation_primary_space_type": "Food and Beverage Service", + "ventilation_secondary_space_type": "Kitchen (cooking)", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 34, + "ventilation_primary_space_type": "Food and Beverage Service", + "ventilation_secondary_space_type": "Restaurant dining rooms", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 70, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 35, + "ventilation_primary_space_type": "Food and Beverage Service, General", + "ventilation_secondary_space_type": "Break rooms", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 36, + "ventilation_primary_space_type": "Food and Beverage Service, General", + "ventilation_secondary_space_type": "Coffee stations", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 37, + "ventilation_primary_space_type": "Food and Beverage Service, General", + "ventilation_secondary_space_type": "Conference/meeting", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 50, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 38, + "ventilation_primary_space_type": "Food and Beverage Service, General", + "ventilation_secondary_space_type": "Corridors", + "ventilation_per_person": null, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": null, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 39, + "ventilation_primary_space_type": "Food and Beverage Service, General", + "ventilation_secondary_space_type": "Occupiable storage rooms for liquids or gels", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 2, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 40, + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Barracks sleeping areas", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 41, + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Bedroom/living room", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 42, + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Laundry rooms, central", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 43, + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Laundry rooms within dwelling units", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 44, + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Lobbies/prefunction", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 30, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 45, + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Multipurpose assembly", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 120, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 46, + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Banks or bank lobbies", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 15, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 47, + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Bank vaults/safe deposit", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 5, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": "yes", + "annotation": "" + }, + { + "id": 48, + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Computer (not printing)", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 4, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 49, + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Freezer and refrigerated spaces (<50\u00b0F [10\u00b0C])", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 50, + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Manufacturing where hazardous materials are not used", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 7, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 51, + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Manufacturing where hazardous materials are used (excludes heavy industrial and chemical processes)", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 7, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 3, + "os": null, + "annotation": "" + }, + { + "id": 52, + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Pharmacy (prep. area)", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 53, + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Photo studios", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 54, + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Shipping/receiving", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 2, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 55, + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Sorting, packing, light assembly", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 7, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 56, + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Telephone closets", + "ventilation_per_person": null, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": null, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 57, + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Transportation waiting", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 58, + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Warehouses", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": null, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 59, + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Breakrooms", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 50, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 60, + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Main entry lobbies", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 61, + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Occupiable storage rooms for dry materials", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 2, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 62, + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Office space", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 5, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 63, + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Reception areas", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 30, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 64, + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Telephone/data entry", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 60, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 65, + "ventilation_primary_space_type": "Outpatient Health Care Facilities", + "ventilation_secondary_space_type": "Birthing room", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 15, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 66, + "ventilation_primary_space_type": "Outpatient Health Care Facilities", + "ventilation_secondary_space_type": "Class 1 imaging rooms", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 5, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 67, + "ventilation_primary_space_type": "Outpatient Health Care Facilities", + "ventilation_secondary_space_type": "Dental operatory", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 68, + "ventilation_primary_space_type": "Outpatient Health Care Facilities", + "ventilation_secondary_space_type": "General examination room", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 69, + "ventilation_primary_space_type": "Outpatient Health Care Facilities", + "ventilation_secondary_space_type": "Other dental treatment areas", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 5, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 70, + "ventilation_primary_space_type": "Outpatient Health Care Facilities", + "ventilation_secondary_space_type": "Physical therapy exercise area", + "ventilation_per_person": 20, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 7, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 71, + "ventilation_primary_space_type": "Outpatient Health Care Facilities", + "ventilation_secondary_space_type": "Physical therapy individual room", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 72, + "ventilation_primary_space_type": "Outpatient Health Care Facilities", + "ventilation_secondary_space_type": "Physical therapeutic pool area", + "ventilation_per_person": null, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.48, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": null, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 73, + "ventilation_primary_space_type": "Outpatient Health Care Facilities", + "ventilation_secondary_space_type": "Prosthetics and orthotics room", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 74, + "ventilation_primary_space_type": "Outpatient Health Care Facilities", + "ventilation_secondary_space_type": "Psychiatric consultation room", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 75, + "ventilation_primary_space_type": "Outpatient Health Care Facilities", + "ventilation_secondary_space_type": "Psychiatric examination room", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 76, + "ventilation_primary_space_type": "Outpatient Health Care Facilities", + "ventilation_secondary_space_type": "Psychiatric group room", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 50, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 77, + "ventilation_primary_space_type": "Outpatient Health Care Facilities", + "ventilation_secondary_space_type": "Psychiatric seclusion room", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 5, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 78, + "ventilation_primary_space_type": "Outpatient Health Care Facilities", + "ventilation_secondary_space_type": "Speech therapy room", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 79, + "ventilation_primary_space_type": "Outpatient Health Care Facilities", + "ventilation_secondary_space_type": "Urgent care examination room", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 80, + "ventilation_primary_space_type": "Outpatient Health Care Facilities", + "ventilation_secondary_space_type": "Urgent care observation room", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 81, + "ventilation_primary_space_type": "Outpatient Health Care Facilities", + "ventilation_secondary_space_type": "Urgent care treatment room", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 82, + "ventilation_primary_space_type": "Outpatient Health Care Facilities", + "ventilation_secondary_space_type": "Urgent care triage room", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 83, + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Auditorium seating area", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 150, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 84, + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Courtrooms", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 70, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 85, + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Legislative chambers", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 50, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 86, + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Libraries (public assembly)", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 87, + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Lobbies", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 150, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 88, + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Museums (children\u2019s)", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 89, + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Museums/galleries", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 90, + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Places of religious worship", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 120, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 91, + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Sales (except as below)", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 15, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 92, + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Barbershop", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": "yes", + "annotation": "" + }, + { + "id": 93, + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Beauty and nail salons", + "ventilation_per_person": 20, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 94, + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Coin-operated laundries", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 95, + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Mall common areas", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 96, + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Pet shops (animal areas)", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 97, + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Supermarket", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 8, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 98, + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Bowling alley (seating)", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.12, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 99, + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Disco/dance floors", + "ventilation_per_person": 20, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": "yes", + "annotation": "" + }, + { + "id": 100, + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Gambling casinos", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 120, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 101, + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Game arcades", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "id": 102, + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Gym, sports arena (play area)", + "ventilation_per_person": 20, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.18, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 7, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 103, + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Health club/aerobics room", + "ventilation_per_person": 20, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 104, + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Health club/weight rooms", + "ventilation_per_person": 20, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 105, + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Spectator areas", + "ventilation_per_person": 7.5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 150, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 106, + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Stages, studios", + "ventilation_per_person": 10, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": 70, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 107, + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Swimming (pool and deck)", + "ventilation_per_person": null, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.48, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": null, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "id": 108, + "ventilation_primary_space_type": "Transient Residential", + "ventilation_secondary_space_type": "Common corridors", + "ventilation_per_person": null, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": null, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + }, + { + "id": 109, + "ventilation_primary_space_type": "Transient Residential", + "ventilation_secondary_space_type": "Dwelling unit", + "ventilation_per_person": 5, + "ventilation_per_person_unit": "cfm/person", + "ventilation_per_area": 0.06, + "ventilation_per_area_unit": "cfm/ft2", + "occupancy_per_area": null, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": "yes", + "annotation": "" + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/initial_data/vent_space_tag.json b/data/openstudio_standards_data/initial_data/vent_space_tag.json new file mode 100644 index 0000000000..bc1269a0ba --- /dev/null +++ b/data/openstudio_standards_data/initial_data/vent_space_tag.json @@ -0,0 +1,332 @@ +[ + { + "vent_space_tag": "correctional_facilities_cell" + }, + { + "vent_space_tag": "correctional_facilities_dayroom" + }, + { + "vent_space_tag": "correctional_facilities_guard_stations" + }, + { + "vent_space_tag": "correctional_facilities_booking_waiting" + }, + { + "vent_space_tag": "educational_facilities_daycare" + }, + { + "vent_space_tag": "educational_facilities_classroom_young" + }, + { + "vent_space_tag": "educational_facilities_classroom_old" + }, + { + "vent_space_tag": "educational_facilities_lecture_classroom" + }, + { + "vent_space_tag": "educational_facilities_lecture_hall" + }, + { + "vent_space_tag": "educational_facilities_art_classroom" + }, + { + "vent_space_tag": "educational_facilities_science_laboratories" + }, + { + "vent_space_tag": "educational_facilities_wood_metal_shop" + }, + { + "vent_space_tag": "educational_facilities_computer_lab" + }, + { + "vent_space_tag": "educational_facilities_media_center" + }, + { + "vent_space_tag": "educational_facilities_music_theater_dance" + }, + { + "vent_space_tag": "educational_facilities_multiuse_assembly" + }, + { + "vent_space_tag": "educational_facilities_daycare_sickroom" + }, + { + "vent_space_tag": "educational_facilities_libraries" + }, + { + "vent_space_tag": "educational_facilities_university_college_laboratories" + }, + { + "vent_space_tag": "food_beverage_service_restaurant_dining_rooms" + }, + { + "vent_space_tag": "food_beverage_service_cafeteria_fast_food_dining" + }, + { + "vent_space_tag": "food_beverage_service_bars_cocktail_lounges" + }, + { + "vent_space_tag": "food_beverage_service_kitchen" + }, + { + "vent_space_tag": "general_conference_meeting" + }, + { + "vent_space_tag": "general_conference_corridors" + }, + { + "vent_space_tag": "general_conference_storage_rooms" + }, + { + "vent_space_tag": "general_break_rooms" + }, + { + "vent_space_tag": "general_coffee_stations" + }, + { + "vent_space_tag": "hotels_motels_resorts_dormitories_bedroom_living_room" + }, + { + "vent_space_tag": "hotels_motels_resorts_dormitories_barracks_sleeping_areas" + }, + { + "vent_space_tag": "hotels_motels_resorts_dormitories_lobbies_prefunction" + }, + { + "vent_space_tag": "hotels_motels_resorts_dormitories_multi_purpose_assembly" + }, + { + "vent_space_tag": "hotels_motels_resorts_dormitories_laundry_rooms" + }, + { + "vent_space_tag": "hotels_motels_resorts_dormitories_laundry_rooms_w_dwelling_units" + }, + { + "vent_space_tag": "office_buildings_office_space" + }, + { + "vent_space_tag": "office_buildings_reception_areas" + }, + { + "vent_space_tag": "office_buildings_telephone_data_entry" + }, + { + "vent_space_tag": "office_buildings_main_entry_lobbies" + }, + { + "vent_space_tag": "office_buildings_breakrooms" + }, + { + "vent_space_tag": "office_buildings_occupiable_storage_rooms" + }, + { + "vent_space_tag": "miscellaneous_spaces_bank_ vaults_safe_deposit" + }, + { + "vent_space_tag": "miscellaneous_spaces_computer" + }, + { + "vent_space_tag": "miscellaneous_spaces_pharmacy" + }, + { + "vent_space_tag": "miscellaneous_spaces_photo_studios" + }, + { + "vent_space_tag": "miscellaneous_spaces_shipping_receiving" + }, + { + "vent_space_tag": "miscellaneous_spaces_transportation_waiting" + }, + { + "vent_space_tag": "miscellaneous_spaces_warehouses" + }, + { + "vent_space_tag": "miscellaneous_spaces_banks_bank_lobbies" + }, + { + "vent_space_tag": "miscellaneous_spaces_freezer_refrigerated_spaces" + }, + { + "vent_space_tag": "miscellaneous_spaces_manufacturing_wo_hazardous_materials" + }, + { + "vent_space_tag": "miscellaneous_spaces_manufacturing_w_hazardous_materials" + }, + { + "vent_space_tag": "miscellaneous_spaces_sorting_packing_light_assembly" + }, + { + "vent_space_tag": "miscellaneous_spaces_telephone_closets" + }, + { + "vent_space_tag": "public_assembly_spaces_auditorium_seating_area" + }, + { + "vent_space_tag": "public_assembly_spaces_religious_workshop" + }, + { + "vent_space_tag": "public_assembly_spaces_courtrooms" + }, + { + "vent_space_tag": "public_assembly_spaces_legislative_chambers" + }, + { + "vent_space_tag": "public_assembly_spaces_libraries" + }, + { + "vent_space_tag": "public_assembly_spaces_lobbies" + }, + { + "vent_space_tag": "public_assembly_spaces_children_museums" + }, + { + "vent_space_tag": "public_assembly_spaces_museums_galleries" + }, + { + "vent_space_tag": "retail_sales" + }, + { + "vent_space_tag": "retail_mall_common_areas" + }, + { + "vent_space_tag": "retail_barbershop" + }, + { + "vent_space_tag": "retail_beauty_nail_salons" + }, + { + "vent_space_tag": "retail_pet_shops" + }, + { + "vent_space_tag": "retail_supermarket" + }, + { + "vent_space_tag": "retail_coin_operated_laundries" + }, + { + "vent_space_tag": "sports_entertainment_sports_arena" + }, + { + "vent_space_tag": "sports_entertainment_gym_stadium" + }, + { + "vent_space_tag": "sports_entertainment_spectator_areas" + }, + { + "vent_space_tag": "sports_entertainment_swimming" + }, + { + "vent_space_tag": "sports_entertainment_disco_dance_floors" + }, + { + "vent_space_tag": "sports_entertainment_health_club_aerobics_room" + }, + { + "vent_space_tag": "sports_entertainment_health_club_weight_rooms" + }, + { + "vent_space_tag": "sports_entertainment_bowling_alley" + }, + { + "vent_space_tag": "sports_entertainment_gambling_casinos" + }, + { + "vent_space_tag": "sports_entertainment_game_arcades" + }, + { + "vent_space_tag": "sports_entertainment_stages_studios" + }, + { + "vent_space_tag": "animal_facilities_animal_exam_room" + }, + { + "vent_space_tag": "animal_facilities_animal_imaging" + }, + { + "vent_space_tag": "animal_facilities_animal_operating_rooms" + }, + { + "vent_space_tag": "animal_facilities_animal_postoperative_recovery_room" + }, + { + "vent_space_tag": "animal_facilities_animal_preparation_rooms" + }, + { + "vent_space_tag": "animal_facilities_animal_procedure_room" + }, + { + "vent_space_tag": "animal_facilities_animal_surgery_scrub" + }, + { + "vent_space_tag": "animal_facilities_large_animal_holding_room" + }, + { + "vent_space_tag": "animal_facilities_necropsy" + }, + { + "vent_space_tag": "animal_facilities_small_animal_cage_room_static" + }, + { + "vent_space_tag": "animal_facilities_small_animal_cage_room_ventilated" + }, + { + "vent_space_tag": "outpatient_health_care_facilities_birthing_room" + }, + { + "vent_space_tag": "outpatient_health_care_facilities_class_1_imaging_rooms" + }, + { + "vent_space_tag": "outpatient_health_care_facilities_dental_operatory" + }, + { + "vent_space_tag": "outpatient_health_care_facilities_general_examination_room" + }, + { + "vent_space_tag": "outpatient_health_care_facilities_other_dental_treatment_areas" + }, + { + "vent_space_tag": "outpatient_health_care_facilities_physical_therapy_exercise_area" + }, + { + "vent_space_tag": "outpatient_health_care_facilities_physical_therapy_individual_room" + }, + { + "vent_space_tag": "outpatient_health_care_facilities_physical_therapeutic_pool_area" + }, + { + "vent_space_tag": "outpatient_health_care_facilities_prosthetics_orthotics_room" + }, + { + "vent_space_tag": "outpatient_health_care_facilities_psychiatric_consultation_room" + }, + { + "vent_space_tag": "outpatient_health_care_facilities_psychiatric_examination_room" + }, + { + "vent_space_tag": "outpatient_health_care_facilities_psychiatric_group_room" + }, + { + "vent_space_tag": "outpatient_health_care_facilities_psychiatric_seclusion_room" + }, + { + "vent_space_tag": "outpatient_health_care_facilities_speech_therapy_room" + }, + { + "vent_space_tag": "outpatient_health_care_facilities_urgent_care_examination_room" + }, + { + "vent_space_tag": "outpatient_health_care_facilities_urgent_care_observation_room" + }, + { + "vent_space_tag": "outpatient_health_care_facilities_urgent_care_treatment_room" + }, + { + "vent_space_tag": "outpatient_health_care_facilities_urgent_care_triage_room" + }, + { + "vent_space_tag": "transient_residential_common_corridors" + }, + { + "vent_space_tag": "transient_residential_dwelling_unit" + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/initial_data/vent_subspaces.json b/data/openstudio_standards_data/initial_data/vent_subspaces.json new file mode 100644 index 0000000000..2798bc1aa6 --- /dev/null +++ b/data/openstudio_standards_data/initial_data/vent_subspaces.json @@ -0,0 +1,1040 @@ +[ + { + "id": 1, + "ventilation_type_name": "correctional_facilities_cell", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 13 + }, + { + "id": 2, + "ventilation_type_name": "correctional_facilities_dayroom", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 14 + }, + { + "id": 3, + "ventilation_type_name": "correctional_facilities_guard_stations", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 15 + }, + { + "id": 4, + "ventilation_type_name": "correctional_facilities_booking_waiting", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 12 + }, + { + "id": 5, + "ventilation_type_name": "educational_facilities_daycare", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 21 + }, + { + "id": 6, + "ventilation_type_name": "educational_facilities_classroom_young", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 17 + }, + { + "id": 7, + "ventilation_type_name": "educational_facilities_classroom_old", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 18 + }, + { + "id": 8, + "ventilation_type_name": "educational_facilities_lecture_classroom", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 22 + }, + { + "id": 9, + "ventilation_type_name": "educational_facilities_lecture_hall", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 23 + }, + { + "id": 10, + "ventilation_type_name": "educational_facilities_art_classroom", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 16 + }, + { + "id": 11, + "ventilation_type_name": "educational_facilities_science_laboratories", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 28 + }, + { + "id": 12, + "ventilation_type_name": "educational_facilities_wood_metal_shop", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 30 + }, + { + "id": 13, + "ventilation_type_name": "educational_facilities_computer_lab", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 19 + }, + { + "id": 14, + "ventilation_type_name": "educational_facilities_media_center", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 25 + }, + { + "id": 15, + "ventilation_type_name": "educational_facilities_music_theater_dance", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 27 + }, + { + "id": 16, + "ventilation_type_name": "educational_facilities_multiuse_assembly", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 26 + }, + { + "id": 17, + "ventilation_type_name": "educational_facilities_daycare_sickroom", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 20 + }, + { + "id": 18, + "ventilation_type_name": "educational_facilities_libraries", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 24 + }, + { + "id": 19, + "ventilation_type_name": "educational_facilities_university_college_laboratories", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 29 + }, + { + "id": 20, + "ventilation_type_name": "food_beverage_service_restaurant_dining_rooms", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 34 + }, + { + "id": 21, + "ventilation_type_name": "food_beverage_service_cafeteria_fast_food_dining", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 32 + }, + { + "id": 22, + "ventilation_type_name": "food_beverage_service_bars_cocktail_lounges", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 31 + }, + { + "id": 23, + "ventilation_type_name": "food_beverage_service_kitchen", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 33 + }, + { + "id": 24, + "ventilation_type_name": "general_conference_meeting", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 37 + }, + { + "id": 25, + "ventilation_type_name": "general_conference_corridors", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 38 + }, + { + "id": 26, + "ventilation_type_name": "general_conference_storage_rooms", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 39 + }, + { + "id": 27, + "ventilation_type_name": "general_break_rooms", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 35 + }, + { + "id": 28, + "ventilation_type_name": "general_coffee_stations", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 36 + }, + { + "id": 29, + "ventilation_type_name": "hotels_motels_resorts_dormitories_bedroom_living_room", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 41 + }, + { + "id": 30, + "ventilation_type_name": "hotels_motels_resorts_dormitories_barracks_sleeping_areas", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 40 + }, + { + "id": 31, + "ventilation_type_name": "hotels_motels_resorts_dormitories_lobbies_prefunction", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 44 + }, + { + "id": 32, + "ventilation_type_name": "hotels_motels_resorts_dormitories_multi_purpose_assembly", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 45 + }, + { + "id": 33, + "ventilation_type_name": "hotels_motels_resorts_dormitories_laundry_rooms", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 42 + }, + { + "id": 34, + "ventilation_type_name": "hotels_motels_resorts_dormitories_laundry_rooms_w_dwelling_units", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 43 + }, + { + "id": 35, + "ventilation_type_name": "office_buildings_office_space", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 62 + }, + { + "id": 36, + "ventilation_type_name": "office_buildings_reception_areas", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 63 + }, + { + "id": 37, + "ventilation_type_name": "office_buildings_telephone_data_entry", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 64 + }, + { + "id": 38, + "ventilation_type_name": "office_buildings_main_entry_lobbies", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 60 + }, + { + "id": 39, + "ventilation_type_name": "office_buildings_breakrooms", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 59 + }, + { + "id": 40, + "ventilation_type_name": "office_buildings_occupiable_storage_rooms", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 61 + }, + { + "id": 41, + "ventilation_type_name": "miscellaneous_spaces_bank_ vaults_safe_deposit", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 47 + }, + { + "id": 42, + "ventilation_type_name": "miscellaneous_spaces_computer", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 48 + }, + { + "id": 43, + "ventilation_type_name": "miscellaneous_spaces_pharmacy", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 52 + }, + { + "id": 44, + "ventilation_type_name": "miscellaneous_spaces_photo_studios", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 53 + }, + { + "id": 45, + "ventilation_type_name": "miscellaneous_spaces_shipping_receiving", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 54 + }, + { + "id": 46, + "ventilation_type_name": "miscellaneous_spaces_transportation_waiting", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 57 + }, + { + "id": 47, + "ventilation_type_name": "miscellaneous_spaces_warehouses", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 58 + }, + { + "id": 48, + "ventilation_type_name": "miscellaneous_spaces_banks_bank_lobbies", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 46 + }, + { + "id": 49, + "ventilation_type_name": "miscellaneous_spaces_freezer_refrigerated_spaces", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 49 + }, + { + "id": 50, + "ventilation_type_name": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 50 + }, + { + "id": 51, + "ventilation_type_name": "miscellaneous_spaces_manufacturing_w_hazardous_materials", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 51 + }, + { + "id": 52, + "ventilation_type_name": "miscellaneous_spaces_sorting_packing_light_assembly", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 55 + }, + { + "id": 53, + "ventilation_type_name": "miscellaneous_spaces_telephone_closets", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 56 + }, + { + "id": 54, + "ventilation_type_name": "public_assembly_spaces_auditorium_seating_area", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 83 + }, + { + "id": 55, + "ventilation_type_name": "public_assembly_spaces_religious_workshop", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 90 + }, + { + "id": 56, + "ventilation_type_name": "public_assembly_spaces_courtrooms", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 84 + }, + { + "id": 57, + "ventilation_type_name": "public_assembly_spaces_legislative_chambers", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 85 + }, + { + "id": 58, + "ventilation_type_name": "public_assembly_spaces_libraries", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 86 + }, + { + "id": 59, + "ventilation_type_name": "public_assembly_spaces_lobbies", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 87 + }, + { + "id": 60, + "ventilation_type_name": "public_assembly_spaces_children_museums", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 88 + }, + { + "id": 61, + "ventilation_type_name": "public_assembly_spaces_museums_galleries", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 89 + }, + { + "id": 62, + "ventilation_type_name": "retail_sales", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 91 + }, + { + "id": 63, + "ventilation_type_name": "retail_mall_common_areas", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 95 + }, + { + "id": 64, + "ventilation_type_name": "retail_barbershop", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 92 + }, + { + "id": 65, + "ventilation_type_name": "retail_beauty_nail_salons", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 93 + }, + { + "id": 66, + "ventilation_type_name": "retail_pet_shops", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 96 + }, + { + "id": 67, + "ventilation_type_name": "retail_supermarket", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 97 + }, + { + "id": 68, + "ventilation_type_name": "retail_coin_operated_laundries", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 94 + }, + { + "id": 69, + "ventilation_type_name": "sports_entertainment_sports_arena", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 102 + }, + { + "id": 70, + "ventilation_type_name": "sports_entertainment_gym_stadium", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 102 + }, + { + "id": 71, + "ventilation_type_name": "sports_entertainment_spectator_areas", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 105 + }, + { + "id": 72, + "ventilation_type_name": "sports_entertainment_swimming", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 107 + }, + { + "id": 73, + "ventilation_type_name": "sports_entertainment_disco_dance_floors", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 99 + }, + { + "id": 74, + "ventilation_type_name": "sports_entertainment_health_club_aerobics_room", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 103 + }, + { + "id": 75, + "ventilation_type_name": "sports_entertainment_health_club_weight_rooms", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 104 + }, + { + "id": 76, + "ventilation_type_name": "sports_entertainment_bowling_alley", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 98 + }, + { + "id": 77, + "ventilation_type_name": "sports_entertainment_gambling_casinos", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 100 + }, + { + "id": 78, + "ventilation_type_name": "sports_entertainment_game_arcades", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 101 + }, + { + "id": 79, + "ventilation_type_name": "sports_entertainment_stages_studios", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 106 + }, + { + "id": 80, + "ventilation_type_name": "animal_facilities_animal_exam_room", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 1 + }, + { + "id": 81, + "ventilation_type_name": "animal_facilities_animal_imaging", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 2 + }, + { + "id": 82, + "ventilation_type_name": "animal_facilities_animal_operating_rooms", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 3 + }, + { + "id": 83, + "ventilation_type_name": "animal_facilities_animal_postoperative_recovery_room", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 4 + }, + { + "id": 84, + "ventilation_type_name": "animal_facilities_animal_preparation_rooms", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 5 + }, + { + "id": 85, + "ventilation_type_name": "animal_facilities_animal_procedure_room", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 6 + }, + { + "id": 86, + "ventilation_type_name": "animal_facilities_animal_surgery_scrub", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 7 + }, + { + "id": 87, + "ventilation_type_name": "animal_facilities_large_animal_holding_room", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 8 + }, + { + "id": 88, + "ventilation_type_name": "animal_facilities_necropsy", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 9 + }, + { + "id": 89, + "ventilation_type_name": "animal_facilities_small_animal_cage_room_static", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 10 + }, + { + "id": 90, + "ventilation_type_name": "animal_facilities_small_animal_cage_room_ventilated", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 11 + }, + { + "id": 91, + "ventilation_type_name": "outpatient_health_care_facilities_birthing_room", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 65 + }, + { + "id": 92, + "ventilation_type_name": "outpatient_health_care_facilities_class_1_imaging_rooms", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 66 + }, + { + "id": 93, + "ventilation_type_name": "outpatient_health_care_facilities_dental_operatory", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 67 + }, + { + "id": 94, + "ventilation_type_name": "outpatient_health_care_facilities_general_examination_room", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 68 + }, + { + "id": 95, + "ventilation_type_name": "outpatient_health_care_facilities_other_dental_treatment_areas", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 69 + }, + { + "id": 96, + "ventilation_type_name": "outpatient_health_care_facilities_physical_therapy_exercise_area", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 70 + }, + { + "id": 97, + "ventilation_type_name": "outpatient_health_care_facilities_physical_therapy_individual_room", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 71 + }, + { + "id": 98, + "ventilation_type_name": "outpatient_health_care_facilities_physical_therapeutic_pool_area", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 72 + }, + { + "id": 99, + "ventilation_type_name": "outpatient_health_care_facilities_prosthetics_orthotics_room", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 73 + }, + { + "id": 100, + "ventilation_type_name": "outpatient_health_care_facilities_psychiatric_consultation_room", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 74 + }, + { + "id": 101, + "ventilation_type_name": "outpatient_health_care_facilities_psychiatric_examination_room", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 75 + }, + { + "id": 102, + "ventilation_type_name": "outpatient_health_care_facilities_psychiatric_group_room", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 76 + }, + { + "id": 103, + "ventilation_type_name": "outpatient_health_care_facilities_psychiatric_seclusion_room", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 77 + }, + { + "id": 104, + "ventilation_type_name": "outpatient_health_care_facilities_speech_therapy_room", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 78 + }, + { + "id": 105, + "ventilation_type_name": "outpatient_health_care_facilities_urgent_care_examination_room", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 79 + }, + { + "id": 106, + "ventilation_type_name": "outpatient_health_care_facilities_urgent_care_observation_room", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 80 + }, + { + "id": 107, + "ventilation_type_name": "outpatient_health_care_facilities_urgent_care_treatment_room", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 81 + }, + { + "id": 108, + "ventilation_type_name": "outpatient_health_care_facilities_urgent_care_triage_room", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 82 + }, + { + "id": 109, + "ventilation_type_name": "transient_residential_common_corridors", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 108 + }, + { + "id": 110, + "ventilation_type_name": "transient_residential_dwelling_unit", + "ventilation_table": "vent_def_62_1_2019", + "vent_621_id": 109 + }, + { + "id": 111, + "ventilation_type_name": "correctional_facilities_cell", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 1 + }, + { + "id": 112, + "ventilation_type_name": "correctional_facilities_dayroom", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 2 + }, + { + "id": 113, + "ventilation_type_name": "correctional_facilities_guard_stations", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 3 + }, + { + "id": 114, + "ventilation_type_name": "correctional_facilities_booking_waiting", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 4 + }, + { + "id": 115, + "ventilation_type_name": "educational_facilities_daycare", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 5 + }, + { + "id": 116, + "ventilation_type_name": "educational_facilities_classroom_young", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 6 + }, + { + "id": 117, + "ventilation_type_name": "educational_facilities_classroom_old", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 7 + }, + { + "id": 118, + "ventilation_type_name": "educational_facilities_lecture_classroom", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 8 + }, + { + "id": 119, + "ventilation_type_name": "educational_facilities_lecture_hall", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 9 + }, + { + "id": 120, + "ventilation_type_name": "educational_facilities_art_classroom", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 10 + }, + { + "id": 121, + "ventilation_type_name": "educational_facilities_science_laboratories", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 11 + }, + { + "id": 122, + "ventilation_type_name": "educational_facilities_wood_metal_shop", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 12 + }, + { + "id": 123, + "ventilation_type_name": "educational_facilities_computer_lab", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 13 + }, + { + "id": 124, + "ventilation_type_name": "educational_facilities_media_center", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 14 + }, + { + "id": 125, + "ventilation_type_name": "educational_facilities_music_theater_dance", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 15 + }, + { + "id": 126, + "ventilation_type_name": "educational_facilities_multiuse_assembly", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 16 + }, + { + "id": 127, + "ventilation_type_name": "food_beverage_service_restaurant_dining_rooms", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 17 + }, + { + "id": 128, + "ventilation_type_name": "food_beverage_service_cafeteria_fast_food_dining", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 18 + }, + { + "id": 129, + "ventilation_type_name": "food_beverage_service_bars_cocktail_lounges", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 19 + }, + { + "id": 130, + "ventilation_type_name": "general_conference_meeting", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 20 + }, + { + "id": 131, + "ventilation_type_name": "general_conference_corridors", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 21 + }, + { + "id": 132, + "ventilation_type_name": "general_conference_storage_rooms", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 22 + }, + { + "id": 133, + "ventilation_type_name": "hotels_motels_resorts_dormitories_bedroom_living_room", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 23 + }, + { + "id": 134, + "ventilation_type_name": "hotels_motels_resorts_dormitories_barracks_sleeping_areas", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 24 + }, + { + "id": 135, + "ventilation_type_name": "hotels_motels_resorts_dormitories_lobbies_prefunction", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 25 + }, + { + "id": 136, + "ventilation_type_name": "hotels_motels_resorts_dormitories_multi_purpose_assembly", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 26 + }, + { + "id": 137, + "ventilation_type_name": "office_buildings_office_space", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 27 + }, + { + "id": 138, + "ventilation_type_name": "office_buildings_reception_areas", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 28 + }, + { + "id": 139, + "ventilation_type_name": "office_buildings_telephone_data_entry", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 29 + }, + { + "id": 140, + "ventilation_type_name": "office_buildings_main_entry_lobbies", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 30 + }, + { + "id": 141, + "ventilation_type_name": "miscellaneous_spaces_bank_ vaults_safe_deposit", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 31 + }, + { + "id": 142, + "ventilation_type_name": "miscellaneous_spaces_computer", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 32 + }, + { + "id": 143, + "ventilation_type_name": "miscellaneous_spaces_pharmacy", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 33 + }, + { + "id": 144, + "ventilation_type_name": "miscellaneous_spaces_photo_studios", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 34 + }, + { + "id": 145, + "ventilation_type_name": "miscellaneous_spaces_shipping_receiving", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 35 + }, + { + "id": 146, + "ventilation_type_name": "miscellaneous_spaces_transportation_waiting", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 36 + }, + { + "id": 147, + "ventilation_type_name": "miscellaneous_spaces_warehouses", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 37 + }, + { + "id": 148, + "ventilation_type_name": "public_assembly_spaces_auditorium_seating_area", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 38 + }, + { + "id": 149, + "ventilation_type_name": "public_assembly_spaces_religious_workshop", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 39 + }, + { + "id": 150, + "ventilation_type_name": "public_assembly_spaces_courtrooms", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 40 + }, + { + "id": 151, + "ventilation_type_name": "public_assembly_spaces_legislative_chambers", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 41 + }, + { + "id": 152, + "ventilation_type_name": "public_assembly_spaces_libraries", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 42 + }, + { + "id": 153, + "ventilation_type_name": "public_assembly_spaces_lobbies", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 43 + }, + { + "id": 154, + "ventilation_type_name": "public_assembly_spaces_children_museums", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 44 + }, + { + "id": 155, + "ventilation_type_name": "public_assembly_spaces_museums_galleries", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 45 + }, + { + "id": 156, + "ventilation_type_name": "retail_sales", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 46 + }, + { + "id": 157, + "ventilation_type_name": "retail_mall_common_areas", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 47 + }, + { + "id": 158, + "ventilation_type_name": "retail_barbershop", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 48 + }, + { + "id": 159, + "ventilation_type_name": "retail_beauty_nail_salons", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 49 + }, + { + "id": 160, + "ventilation_type_name": "retail_pet_shops", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 50 + }, + { + "id": 161, + "ventilation_type_name": "retail_supermarket", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 51 + }, + { + "id": 162, + "ventilation_type_name": "retail_coin_operated_laundries", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 52 + }, + { + "id": 163, + "ventilation_type_name": "sports_entertainment_sports_arena", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 53 + }, + { + "id": 164, + "ventilation_type_name": "sports_entertainment_gym_stadium", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 54 + }, + { + "id": 165, + "ventilation_type_name": "sports_entertainment_spectator_areas", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 55 + }, + { + "id": 166, + "ventilation_type_name": "sports_entertainment_swimming", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 56 + }, + { + "id": 167, + "ventilation_type_name": "sports_entertainment_disco_dance_floors", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 57 + }, + { + "id": 168, + "ventilation_type_name": "sports_entertainment_health_club_aerobics_room", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 58 + }, + { + "id": 169, + "ventilation_type_name": "sports_entertainment_health_club_weight_rooms", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 59 + }, + { + "id": 170, + "ventilation_type_name": "sports_entertainment_bowling_alley", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 60 + }, + { + "id": 171, + "ventilation_type_name": "sports_entertainment_gambling_casinos", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 61 + }, + { + "id": 172, + "ventilation_type_name": "sports_entertainment_game_arcades", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 62 + }, + { + "id": 173, + "ventilation_type_name": "sports_entertainment_stages_studios", + "ventilation_table": "vent_def_62_1_2004", + "vent_621_id": 63 + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/query/__init__.py b/data/openstudio_standards_data/query/__init__.py new file mode 100644 index 0000000000..e69de29bb2 diff --git a/data/openstudio_standards_data/query/fetch/__init__.py b/data/openstudio_standards_data/query/fetch/__init__.py new file mode 100644 index 0000000000..e69de29bb2 diff --git a/data/openstudio_standards_data/query/fetch/database_table.py b/data/openstudio_standards_data/query/fetch/database_table.py new file mode 100644 index 0000000000..2df8745015 --- /dev/null +++ b/data/openstudio_standards_data/query/fetch/database_table.py @@ -0,0 +1,69 @@ +""" +This module fetches the lighting standards +""" +import sqlite3 + +from query.util import ( + _convert_list_tuple_to_list_dict, + _convert_tuple_to_dict, + is_table_exist, +) + + +def fetch_table(conn: sqlite3.Connection, table_name: str): + """ + Fetch all data from a specific table + :param conn: + :param table_name: String data table + :return: list of data or empty list + """ + # Make sure the table exist + if is_table_exist(conn, table_name): + fetch_query = f"""SELECT * FROM {table_name}""" + cur = conn.execute(fetch_query) + data_header = list(map(lambda x: x[0], cur.description)) + + return _convert_list_tuple_to_list_dict(cur.fetchall(), data_header) + return [] + + +def fetch_a_record_from_table_by_id( + conn: sqlite3.Connection, table_name: str, index: int +): + """ + Fetch a data record matched by ID from a specific table + :param conn: + :param table_name: String lighting data table + :param index: Integer, lighting object ID + :return: dict + """ + # Make sure the table exist + if is_table_exist(conn, table_name): + fetch_query = f"""SELECT * FROM {table_name} WHERE id={index}""" + cur = conn.execute(fetch_query) + data_header = list(map(lambda x: x[0], cur.description)) + + return _convert_tuple_to_dict(cur.fetchone(), data_header) + return dict() + + +def fetch_records_from_table_by_key_values( + conn: sqlite3.Connection, table_name: str, key_value_dict: dict +): + """ + Fetch a data record matched by key value pairs in the dict from a specific table + :param conn: + :param table_name: String data table + :param key_value_dict: Dict, key value pair where Key shall be the column name and value shall be the value + :return: dict + """ + # Make sure the table exist + if is_table_exist(conn, table_name): + condition = " AND ".join( + [f"{key} = '{key_value_dict[key]}'" for key in key_value_dict.keys()] + ) + fetch_query = f"""SELECT * FROM {table_name} WHERE {condition}""" + cur = conn.execute(fetch_query) + data_header = list(map(lambda x: x[0], cur.description)) + return _convert_list_tuple_to_list_dict(cur.fetchall(), data_header) + return [] diff --git a/data/openstudio_standards_data/query/fetch/space.py b/data/openstudio_standards_data/query/fetch/space.py new file mode 100644 index 0000000000..3739ab8e10 --- /dev/null +++ b/data/openstudio_standards_data/query/fetch/space.py @@ -0,0 +1,40 @@ +""" +This module contains a number of functions to fetch building data +building data includes: +lighting, ventilation (and more...) +""" +import sqlite3 +from query.util import _convert_list_tuple_to_list_dict + +SPACE_DATA_HEADER = [ + "space_type", + "lighting_space_type_name", + "ventilation_space_type_name", + "level_3_lighting_definition_table", + "level_3_lighting_defintion_id", + "level_3_ventilation_definition_table", + "level_3_ventilation_defintion_id", + "electric_equipment_space_type_name", +] + + +SPACE_JOIN_QUERY = f""" +SELECT {','.join(SPACE_DATA_HEADER)} + FROM level_1_space_types as BS + LEFT JOIN light_subspaces as LS + ON BS.lighting_space_type_name = LS.lighting_space_type_name + LEFT JOIN vent_subspaces as VS + ON BS.ventilation_space_type_name = VS.ventilation_space_type_name +""" + + +def fetch_space_data(connection: sqlite3.Connection): + """ + Fetch building data table + :param connection: + :return: + """ + + return _convert_list_tuple_to_list_dict( + connection.execute(SPACE_JOIN_QUERY).fetchall(), SPACE_DATA_HEADER + ) diff --git a/data/openstudio_standards_data/query/fetch/template.py b/data/openstudio_standards_data/query/fetch/template.py new file mode 100644 index 0000000000..1657c08a51 --- /dev/null +++ b/data/openstudio_standards_data/query/fetch/template.py @@ -0,0 +1,64 @@ +""" +This module contains a number of functions to fetch template +template specify the standard versions for each set of study + +e.g. 2019 -> lighting: ASHRAE 90.1-2019, ventilation: ASHRAE 62.1-2019 +""" +import sqlite3 + +from query.util import _convert_list_tuple_to_list_dict + +DATA_HEADER = [ + "template", + "lighting_standard", + "lighting_standard_table", + "ventilation_standard", + "ventilation_standard_table", +] + +TEMPLATE_QUERY = f""" +SELECT {','.join(DATA_HEADER)} + FROM support_standard_templates +""" + + +def fetch_templates(conn: sqlite3.Connection): + """ + Fetch all template data + :param conn: + :return: + """ + return _convert_list_tuple_to_list_dict( + conn.execute(TEMPLATE_QUERY).fetchall(), DATA_HEADER + ) + + +def fetch_template_data_by_template(conn: sqlite3.Connection, template: str): + """ + Fetch a template record + :param conn: + :param template: string + :return: + """ + template_query = f"""{TEMPLATE_QUERY} WHERE template = ?;""" + return _convert_list_tuple_to_list_dict( + conn.execute(template_query, (template,)).fetchall(), DATA_HEADER + ) + + +def fetch_template_data_by_template_first(conn: sqlite3.Connection, template: str): + """ + Fetch a template record + :param conn: + :param template: string + :return: + """ + template_query = f"""{TEMPLATE_QUERY} WHERE template = ?;""" + fetched_data = _convert_list_tuple_to_list_dict( + conn.execute(template_query, (template,)).fetchall(), DATA_HEADER + ) + assert ( + len(fetched_data) > 0 + ), f"Cannot find matched template '{template}' in the openstudio_standards database" + + return fetched_data[0] diff --git a/data/openstudio_standards_data/query/update/__init__.py b/data/openstudio_standards_data/query/update/__init__.py new file mode 100644 index 0000000000..e69de29bb2 diff --git a/data/openstudio_standards_data/query/update/update_a_table.py b/data/openstudio_standards_data/query/update/update_a_table.py new file mode 100644 index 0000000000..2f907825eb --- /dev/null +++ b/data/openstudio_standards_data/query/update/update_a_table.py @@ -0,0 +1,28 @@ +import sqlite3 + + +def update_a_table( + conn: sqlite3.Connection, table_name: str, update_dict: dict, search_condition: str +): + """ + Update a table data based on search conditions and update values - + there is no order by and limit. + + :param conn: sqlite3.Connection + :param table_name: table name + :param update_dict: dictionary contains the key-value data pair where key is the table column header and value is + the new value. Note, None is allowed and will not add to the updates + :param search_condition: str a search criteria string composed by the client end. e.g. "id = 11" + :return: true update successfully, false failed + """ + + set_str_value = [ + f"{key}='{update_dict[key]}'" for key in update_dict.keys() if update_dict[key] + ] + + UPDATE_QUERY = f""" + UPDATE {table_name} + SET {','.join(set_str_value)} + WHERE {search_condition} + """ + return conn.execute(UPDATE_QUERY) and conn.commit() if set_str_value else None diff --git a/data/openstudio_standards_data/query/util.py b/data/openstudio_standards_data/query/util.py new file mode 100644 index 0000000000..507eb51099 --- /dev/null +++ b/data/openstudio_standards_data/query/util.py @@ -0,0 +1,54 @@ +import sqlite3 +from typing import List + + +def _convert_list_tuple_to_list_dict(data: List[tuple], data_head_list: List[str]): + """ + convert list of tuples of data to list of dictionary + :param data: list[tuple] data list + :param data_head_list: list[string] data header list + :return: list[dict] + """ + return [dict(zip(data_head_list, data_tuple)) for data_tuple in data] + + +def _convert_tuple_to_dict(data: tuple, data_head_list: List[str]): + """ + convert a tuple to a dictionary + :param data: tuple + :param data_head_list: list[str] + :return: dict + """ + return dict(zip(data_head_list, data)) + + +def is_table_exist(conn: sqlite3.Connection, table_name): + """ + Utility function to ensure the table name provided is correct and exist in the openstudio_standards data tables + :param conn: + :param table_name: + :return: + """ + cur = conn.cursor() + list_of_tables = cur.execute( + f"""SELECT tbl_name FROM sqlite_master WHERE type='table' AND tbl_name='{table_name}'""" + ).fetchall() + return True if list_of_tables else False + + +def match_dict_data_by_key(primary_data: dict, secondary_data: dict): + """ + This function matches two data dictionaries (primary_data, secondary_data) and return only the matched portion of the dictionary + Match only applies when only key is matched. + + If key matched, the value will use the one_data value + + :param primary_data: + :param secondary_data: + :return: + """ + return { + key: primary_data[key] + for key in primary_data.keys() + if key in secondary_data.keys() + } diff --git a/data/openstudio_standards_data/test/__init__.py b/data/openstudio_standards_data/test/__init__.py new file mode 100644 index 0000000000..e69de29bb2 diff --git a/data/openstudio_standards_data/test/test_database.py b/data/openstudio_standards_data/test/test_database.py new file mode 100644 index 0000000000..a7a224d012 --- /dev/null +++ b/data/openstudio_standards_data/test/test_database.py @@ -0,0 +1,48 @@ +from unittest import TestCase +from unittest import mock +import os +import sqlite3 +from applications.database_maintenance import ( + create_openstudio_standards_database_from_csv, +) + + +class TestDatabaseQuries(TestCase): + """ + Test database - unfinished + """ + + def fix_dbc(self): + dbc = mock.MagicMock(spec=["cursor"]) + dbc.autocommit = True + return dbc + + def fix_rows(self): + rows = [{"id": 1, "name": "John"}, {"id": 2, "name": "Jane"}] + return rows + + def test_insert_rows_calls_cursor_method(self): + dbc = self.fix_dbc() + rows = self.fix_rows() + pass + + +def test_create_database(): + # Create DB + db_name = "openstudio_standards_data" + if os.path.isfile(f"{db_name}.db"): + os.remove(f"{db_name}.db") + conn = sqlite3.connect(f"{db_name}.db") + create_openstudio_standards_database_from_csv(conn) + + # Check that DB exists + assert os.path.isfile(f"{db_name}.db") + + # Foreign key check + cur = conn.cursor() + cur.execute("PRAGMA foreign_key_check;") + res = cur.fetchall() + assert len(res) == 0, f"Foreign key issue: {res}" + + # Close DB + conn.close() diff --git a/data/openstudio_standards_data/test/test_template.py b/data/openstudio_standards_data/test/test_template.py new file mode 100644 index 0000000000..24fc41d703 --- /dev/null +++ b/data/openstudio_standards_data/test/test_template.py @@ -0,0 +1,39 @@ +import sqlite3, os + +from query.fetch.template import fetch_templates, fetch_template_data_by_template +from applications.database_maintenance import ( + create_openstudio_standards_database_from_csv, +) + +db_name = "openstudio_standards_data" +if os.path.isfile(f"{db_name}.db"): + os.remove(f"{db_name}.db") +conn = sqlite3.connect(f"{db_name}.db") +create_openstudio_standards_database_from_csv(conn) +conn.close() +assert os.path.isfile(f"{db_name}.db") + + +def test_get_template_data__true(): + connection = sqlite3.connect(f"{db_name}.db") + assert fetch_templates(connection)[0] == { + "template": "90.1-2019", + "lighting_standard": "ASHRAE 90.1-2019", + "lighting_standard_table": "level_3_lighting_90_1_2019", + "ventilation_standard": "ASHRAE 62.1-2019", + "ventilation_standard_table": "level_3_ventilation_90_1_2019", + } + + +def test_get_template_data_by_template__true(): + template = "90.1-2019" + connection = sqlite3.connect(f"{db_name}.db") + assert fetch_template_data_by_template(connection, template) == [ + { + "template": "90.1-2019", + "lighting_standard": "ASHRAE 90.1-2019", + "lighting_standard_table": "level_3_lighting_90_1_2019", + "ventilation_standard": "ASHRAE 62.1-2019", + "ventilation_standard_table": "level_3_ventilation_90_1_2019", + } + ] From bf9165b75d40997f7b0e0c4423225440c500ebd4 Mon Sep 17 00:00:00 2001 From: Jeremy L <5149279+lymereJ@users.noreply.github.com> Date: Thu, 23 Mar 2023 10:47:05 -0700 Subject: [PATCH 05/45] Move data files (#1464) * small change to test action * add working directory * ad database code * update yml for action * reformat. * add engine print for action debug * remove byte data * Remove byte from ventilation data * black format * test if code change in osstd would trigger action * add code to prevent action running if no changes in the database folder. * add condition to remove the tests * update script * revise typo * change to a new folder * remove the code chaneg detection * remove needs * Revert changes to Standards.Model and Standards.Space * add python file ignores * Remove pyc files, pip lock file, and other misc files. * File lock is needed for tests. * Move files. * Initial data files. * Remove ids from tables, and temporary remove JSON files. * Black. --------- Co-authored-by: Weili Xu --- data/openstudio_standards_data/README.md | 10 +- .../create_openstudio_standards_json.py | 6 +- data/openstudio_standards_data/client.py | 2 +- .../database_files/envelope_requirement.csv | 4534 +++++++++++++++++ .../hvac_minimum_requirement_boilers_90_1.csv | 22 + ...hvac_minimum_requirement_chillers_90_1.csv | 163 + ...hvac_minimum_requirement_furnaces_90_1.csv | 13 + ...mum_requirement_heat_pump_cooling_90_1.csv | 165 + ...mum_requirement_heat_pump_heating_90_1.csv | 51 + ...inimum_requirement_heat_rejection_90_1.csv | 31 + .../hvac_minimum_requirement_motors_90_1.csv | 148 + ...uirement_unitary_air_conditioners_90_1.csv | 196 + ...minimum_requirement_water_heaters_90_1.csv | 25 + ...t_water_source_heat_pumps_cooling_90_1.csv | 19 + ...t_water_source_heat_pumps_heating_90_1.csv | 7 + .../database_files/level_1_space_types.csv | 129 + .../level_2_electric_equipment.csv | 91 + .../level_2_lighting_space_types.csv | 287 ++ .../level_2_ventilation_space_types.csv | 174 + .../level_3_lighting_90_1_2004.csv | 126 + .../level_3_lighting_90_1_2019.csv | 139 + .../level_3_ventilation_62_1_2004.csv | 64 + .../level_3_ventilation_62_1_2019.csv | 110 + .../database_files/support_constructions.csv | 492 ++ ...lectric_equipment_space_type_name_tags.csv | 155 + .../support_lighting_space_type_name_tags.csv | 159 + .../database_files/support_materials.csv | 1390 +++++ .../support_performance_curves.csv | 734 +++ .../support_standard_templates.csv | 3 + ...pport_ventilation_space_type_name_tags.csv | 111 + .../system_requirement_economizer_90_1.csv | 497 ++ ...ystem_requirement_energy_recovery_90_1.csv | 409 ++ .../database_tables/envelope_requirement.py | 2 +- .../hvac_minimum_requirement_boilers_90_1.py | 2 +- .../hvac_minimum_requirement_chillers_90_1.py | 2 +- .../hvac_minimum_requirement_furnaces_90_1.py | 2 +- ...imum_requirement_heat_pump_cooling_90_1.py | 2 +- ...imum_requirement_heat_pump_heating_90_1.py | 2 +- ...minimum_requirement_heat_rejection_90_1.py | 2 +- .../hvac_minimum_requirement_motors_90_1.py | 2 +- ...quirement_unitary_air_conditioners_90_1.py | 2 +- ..._minimum_requirement_water_heaters_90_1.py | 2 +- ...nt_water_source_heat_pumps_cooling_90_1.py | 2 +- ...nt_water_source_heat_pumps_heating_90_1.py | 2 +- .../database_tables/level_1_space_types.py | 2 +- .../level_2_electric_equipment.py | 2 +- .../level_2_lighting_space_types.py | 2 +- .../level_2_ventilation_space_types.py | 2 +- .../level_3_lighting_90_1_2004.py | 2 +- .../level_3_lighting_90_1_2019.py | 2 +- .../level_3_ventilation_62_1_2004.py | 2 +- .../level_3_ventilation_62_1_2019.py | 2 +- .../database_tables/support_constructions.py | 2 +- ...electric_equipment_space_type_name_tags.py | 2 +- .../support_lighting_space_type_name_tags.py | 2 +- .../database_tables/support_materials.py | 2 +- .../support_performance_curves.py | 2 +- .../support_standard_templates.py | 2 +- ...upport_ventilation_space_type_name_tags.py | 2 +- .../system_requirement_economizer_90_1.py | 2 +- ...system_requirement_energy_recovery_90_1.py | 2 +- 61 files changed, 10483 insertions(+), 37 deletions(-) create mode 100644 data/openstudio_standards_data/database_files/envelope_requirement.csv create mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_boilers_90_1.csv create mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_chillers_90_1.csv create mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_furnaces_90_1.csv create mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_pump_cooling_90_1.csv create mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_pump_heating_90_1.csv create mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_rejection_90_1.csv create mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_motors_90_1.csv create mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_unitary_air_conditioners_90_1.csv create mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_heaters_90_1.csv create mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1.csv create mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_source_heat_pumps_heating_90_1.csv create mode 100644 data/openstudio_standards_data/database_files/level_1_space_types.csv create mode 100644 data/openstudio_standards_data/database_files/level_2_electric_equipment.csv create mode 100644 data/openstudio_standards_data/database_files/level_2_lighting_space_types.csv create mode 100644 data/openstudio_standards_data/database_files/level_2_ventilation_space_types.csv create mode 100644 data/openstudio_standards_data/database_files/level_3_lighting_90_1_2004.csv create mode 100644 data/openstudio_standards_data/database_files/level_3_lighting_90_1_2019.csv create mode 100644 data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2004.csv create mode 100644 data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.csv create mode 100644 data/openstudio_standards_data/database_files/support_constructions.csv create mode 100644 data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.csv create mode 100644 data/openstudio_standards_data/database_files/support_lighting_space_type_name_tags.csv create mode 100644 data/openstudio_standards_data/database_files/support_materials.csv create mode 100644 data/openstudio_standards_data/database_files/support_performance_curves.csv create mode 100644 data/openstudio_standards_data/database_files/support_standard_templates.csv create mode 100644 data/openstudio_standards_data/database_files/support_ventilation_space_type_name_tags.csv create mode 100644 data/openstudio_standards_data/database_files/system_requirement_economizer_90_1.csv create mode 100644 data/openstudio_standards_data/database_files/system_requirement_energy_recovery_90_1.csv diff --git a/data/openstudio_standards_data/README.md b/data/openstudio_standards_data/README.md index 8d1ba130ca..16df5c004c 100644 --- a/data/openstudio_standards_data/README.md +++ b/data/openstudio_standards_data/README.md @@ -1,9 +1,10 @@ -## Data Refactor Repo +# OpenStudio Standards Data +This folder contains code that manages the data needed by OpenStudio Standards to operate -### Prerequisite +## Prerequisites Python 3.10 (3.9 could work but not tested) -### How to use +## Quick Start Guide Clone this repo To create the full database in your local repo: @@ -19,8 +20,7 @@ conn.close() This code will generate an `openstudio_standards_database.sql` in the same file directory. - -### How to contribute: +## How to contribute 1. Create a new branch 2. Write code 3. Run `pipenv run black .` -> format your code diff --git a/data/openstudio_standards_data/applications/create_openstudio_standards_json.py b/data/openstudio_standards_data/applications/create_openstudio_standards_json.py index bd24ceeb56..0cb24a4066 100644 --- a/data/openstudio_standards_data/applications/create_openstudio_standards_json.py +++ b/data/openstudio_standards_data/applications/create_openstudio_standards_json.py @@ -13,9 +13,11 @@ from query.fetch.template import fetch_templates -def create_osstd_space_data_json(conn: sqlite3.Connection, json_data_dir: str): +def create_openstudio_standards_space_data_json( + conn: sqlite3.Connection, json_data_dir: str +): """ - Extract osstd building data to a json file. + Extract OpenSutdio Standards building data to a json file. :param conn: database connection :param json_data_dir: directory :return: diff --git a/data/openstudio_standards_data/client.py b/data/openstudio_standards_data/client.py index 7abc5c9f17..9683bf6c1f 100644 --- a/data/openstudio_standards_data/client.py +++ b/data/openstudio_standards_data/client.py @@ -18,7 +18,7 @@ # create_openstudio_standards_database_from_csv(conn) # a = fetch_a_record_from_table_by_id(conn, "level_3_lighting_90_1_2019", 1) # export_openstudio_standards_database_to_csv(conn, "") -# export_openstudio_standards_database_to_json(conn, "initial_data/") +# export_openstudio_standards_database_to_json(conn, "database_files/") # create_openstudio_standards_database_from_json(conn) # create_openstudio_standards_building_data_json(conn, 'openstudio_standards_building_data.json') update_json = [ diff --git a/data/openstudio_standards_data/database_files/envelope_requirement.csv b/data/openstudio_standards_data/database_files/envelope_requirement.csv new file mode 100644 index 0000000000..19467ee5b2 --- /dev/null +++ b/data/openstudio_standards_data/database_files/envelope_requirement.csv @@ -0,0 +1,4534 @@ +template,climate_zone_set,intended_surface_type,standards_construction_type,building_category,construction,orientation,minimum_percent_of_surface,maximum_percent_of_surface,assembly_maximum_u_value,u_value_includes_interior_film_coefficient,u_value_includes_exterior_film_coefficient,asssembly_maximum_f_factor,assembly_maximum_c_factor,assembly_maximum_solar_heat_gain_coefficient,assembly_minimum_vt_shgc,annotation +90.1-2004,ClimateZone 1,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 1,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,1.282,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.614,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,1.28,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2004,ClimateZone 1,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,1.18,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 2,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.167,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2004,ClimateZone 2,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.184,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 2,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 2,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 2,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 2,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 2,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 2,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 2,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 2,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 2,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 2,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 2,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 2,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.34 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 2,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 2,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 2,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 2,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 3A,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 3B,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 3C,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 3,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2004,ClimateZone 3A,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2004,ClimateZone 3B,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2004,ClimateZone 3C,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2004,ClimateZone 3,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2004,ClimateZone 3A,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2004,ClimateZone 3B,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2004,ClimateZone 3C,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2004,ClimateZone 3,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 3A,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 3B,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 3C,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 3A,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.184,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 3A,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 3A,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 3A,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 3A,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 3A,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 3A,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 3A,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 3A,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 3A,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.39 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.36 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.34 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.34,, +90.1-2004,ClimateZone 3A,Skylight,Plastic with Curb,Nonresidential,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.27,, +90.1-2004,ClimateZone 3A,Skylight,Plastic with Curb,Residential,U 1.30 SHGC 0.27 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.27,, +90.1-2004,ClimateZone 3A,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.39 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3A,Skylight,Without Curb,Residential,U 0.69 SHGC 0.36 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 3A,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3B,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.184,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 3B,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 3B,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 3B,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 3B,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 3B,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 3B,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 3B,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 3B,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 3B,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.39 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3B,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.36 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,Skylight,Plastic with Curb,Nonresidential,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3B,Skylight,Plastic with Curb,Residential,U 1.30 SHGC 0.27 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 3B,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3B,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.39 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,Skylight,Without Curb,Residential,U 0.69 SHGC 0.36 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3B,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.65,, +90.1-2004,ClimateZone 3C,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.184,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.61,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.61,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.61,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Residential,U 0.72 SHGC 0.25 Simple Glazing Window,,40.001,100,0.72,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.72 SHGC 0.25 Simple Glazing Window,,40.001,100,0.72,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Residential,U 0.72 SHGC 0.25 Simple Glazing Window,,40.001,100,0.72,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.61,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Residential,U 0.72 SHGC 0.25 Simple Glazing Window,,40.001,100,0.72,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 3C,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 3C,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 3C,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 3C,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 3C,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 3C,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 3C,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 3C,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 3C,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.61 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.27,, +90.1-2004,ClimateZone 3C,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.39 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.27,, +90.1-2004,ClimateZone 3C,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.39 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.65 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.65 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 3C,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 3C,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.61 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 3C,Skylight,Without Curb,Residential,U 1.36 SHGC 0.39 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 3C,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 4,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2004,ClimateZone 4,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.134,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 4,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.95,,,, +90.1-2004,ClimateZone 4,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 4,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.84,,,, +90.1-2004,ClimateZone 4,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 4,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 4,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 4,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 4,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 4,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 4,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 4,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.36 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 4,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 4,Skylight,Plastic with Curb,Nonresidential,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,Skylight,Plastic with Curb,Residential,U 1.30 SHGC 0.62 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 4,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.65,, +90.1-2004,ClimateZone 4,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.27,, +90.1-2004,ClimateZone 4,Skylight,Without Curb,Residential,U 0.58 SHGC 0.36 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,0.27,, +90.1-2004,ClimateZone 4,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 5,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2004,ClimateZone 5,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 5,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.84,,,, +90.1-2004,ClimateZone 5,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 5,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.84,,,, +90.1-2004,ClimateZone 5,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 5,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 5,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 5,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 5,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 5,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 5,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.36 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 5,Skylight,Plastic with Curb,Nonresidential,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 5,Skylight,Plastic with Curb,Residential,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 5,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.61,, +90.1-2004,ClimateZone 5,Skylight,Without Curb,Residential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 5,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 6,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.0066,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 6,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2004,ClimateZone 6,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 6,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.84,,,, +90.1-2004,ClimateZone 6,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 6,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.78,,,, +90.1-2004,ClimateZone 6,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 6,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 6,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 6,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 6,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2004,ClimateZone 6,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 6,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.45 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.65 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.65,, +90.1-2004,ClimateZone 6,Skylight,Plastic with Curb,Nonresidential,U 0.87 SHGC 0.71 Simple Glazing Skylight,,0,2,0.87,TRUE,TRUE,,,0.65,, +90.1-2004,ClimateZone 6,Skylight,Plastic with Curb,Residential,U 0.74 SHGC 0.65 Simple Glazing Skylight,,0,2,0.74,TRUE,TRUE,,,0.34,, +90.1-2004,ClimateZone 6,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 6,Skylight,Without Curb,Residential,U 0.58 SHGC 0.61 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,0.61,, +90.1-2004,ClimateZone 6,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.39,, +90.1-2004,ClimateZone 7,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 7,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2004,ClimateZone 7,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 7,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.84,,,, +90.1-2004,ClimateZone 7,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, +90.1-2004,ClimateZone 7,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.78,,,, +90.1-2004,ClimateZone 7,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 7,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 7,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 7,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2004,ClimateZone 7,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2004,ClimateZone 7,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 7,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.68 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 7,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.64 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,Skylight,Plastic with Curb,Nonresidential,U 0.87 SHGC 0.77 Simple Glazing Skylight,,0,2,0.87,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 7,Skylight,Plastic with Curb,Residential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 7,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 7,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.68 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,Skylight,Without Curb,Residential,U 0.69 SHGC 0.64 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 7,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.65,, +90.1-2004,ClimateZone 8,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 8,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.072,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2004,ClimateZone 8,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.055,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, +90.1-2004,ClimateZone 8,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.78,,,, +90.1-2004,ClimateZone 8,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2004,ClimateZone 8,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.78,,,, +90.1-2004,ClimateZone 8,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 8,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.95,,,, +90.1-2004,ClimateZone 8,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 8,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2004,ClimateZone 8,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2004,ClimateZone 8,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 8,Skylight,Glass with Curb,Nonresidential,U 0.98 SHGC 0.62 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.62,, +90.1-2004,ClimateZone 8,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.27 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.27,, +90.1-2004,ClimateZone 8,Skylight,Glass with Curb,Semiheated,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,Skylight,Plastic with Curb,Nonresidential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,Skylight,Plastic with Curb,Residential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,0.49,, +90.1-2004,ClimateZone 8,Skylight,Plastic with Curb,Semiheated,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 8,Skylight,Without Curb,Nonresidential,U 0.58 SHGC 0.19 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 8,Skylight,Without Curb,Residential,U 0.58 SHGC 0.45 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 8,Skylight,Without Curb,Semiheated,U 0.81 SHGC 0.65 Simple Glazing Skylight,,0,2,0.81,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 1,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 1,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 1,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 1,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 1,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 1,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 1,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 1,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 1,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 1,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.36 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 1,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 1,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.16 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.16,, +90.1-2004,ClimateZone 1,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.34 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 1,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.34,, +90.1-2004,ClimateZone 1,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.27,, +90.1-2004,ClimateZone 1,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.27,, +90.1-2004,ClimateZone 1,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 1,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.065,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.063,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.65,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,1.28,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2007,ClimateZone 1,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 2,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.167,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2007,ClimateZone 2,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.184,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2007,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.7 SHGC 0.25 Simple Glazing Window,,,,0.7,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.7 SHGC 0.25 Simple Glazing Window,,,,0.7,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 2,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2007,ClimateZone 2,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 2,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2007,ClimateZone 2,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 2,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2007,ClimateZone 2,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 2,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 2,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 2,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 2,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.49,, +90.1-2007,ClimateZone 2,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.49 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.49,, +90.1-2007,ClimateZone 2,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.39,, +90.1-2007,ClimateZone 2,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 2,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.49,, +90.1-2007,ClimateZone 2,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.46,, +90.1-2007,ClimateZone 2,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.36,, +90.1-2007,ClimateZone 3,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 3,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2007,ClimateZone 3,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.184,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2007,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 3,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 3,ExteriorWindow,Metal framing (all other),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.9 SHGC 0.25 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 3,GlassDoor,Metal framing (entrance door),Residential,U 0.9 SHGC 0.25 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 3,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 3,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2007,ClimateZone 3,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 3,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.09,,,, +90.1-2007,ClimateZone 3,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 3,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2007,ClimateZone 3,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 3,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 3,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 3,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 3,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.39 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.36 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.71 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.71,, +90.1-2007,ClimateZone 3,Skylight,Plastic with Curb,Nonresidential,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.65,, +90.1-2007,ClimateZone 3,Skylight,Plastic with Curb,Residential,U 1.30 SHGC 0.27 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.55,, +90.1-2007,ClimateZone 3,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.39 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 3,Skylight,Without Curb,Residential,U 0.69 SHGC 0.36 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.49,, +90.1-2007,ClimateZone 3,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.49,, +90.1-2007,ClimateZone 4,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 4,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2007,ClimateZone 4,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.134,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2007,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.4 SHGC 0.4 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.4 SHGC 0.4 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.85 SHGC 0.4 Simple Glazing Window,,,,0.85,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.85 SHGC 0.4 Simple Glazing Window,,,,0.85,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 4,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2007,ClimateZone 4,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, +90.1-2007,ClimateZone 4,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2007,ClimateZone 4,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 4,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2007,ClimateZone 4,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 4,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 4,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2007,ClimateZone 4,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 4,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.39,, +90.1-2007,ClimateZone 4,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.36 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,Skylight,Plastic with Curb,Nonresidential,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.68,, +90.1-2007,ClimateZone 4,Skylight,Plastic with Curb,Residential,U 1.30 SHGC 0.62 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.64,, +90.1-2007,ClimateZone 4,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.64,, +90.1-2007,ClimateZone 4,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,Skylight,Without Curb,Residential,U 0.58 SHGC 0.36 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 4,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.77,, +90.1-2007,ClimateZone 5,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 5,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.119,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2007,ClimateZone 5,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2007,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 5,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2007,ClimateZone 5,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, +90.1-2007,ClimateZone 5,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2007,ClimateZone 5,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 5,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2007,ClimateZone 5,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 5,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2007,ClimateZone 5,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2007,ClimateZone 5,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 5,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.77,, +90.1-2007,ClimateZone 5,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.77,, +90.1-2007,ClimateZone 5,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,Skylight,Plastic with Curb,Nonresidential,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,Skylight,Plastic with Curb,Residential,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,0.68,, +90.1-2007,ClimateZone 5,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.64,, +90.1-2007,ClimateZone 5,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.64,, +90.1-2007,ClimateZone 5,Skylight,Without Curb,Residential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 5,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 6,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2007,ClimateZone 6,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2007,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.6 SHGC 0.45 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, +90.1-2007,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 0.9 SHGC 0.45 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, +90.1-2007,ClimateZone 6,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2007,ClimateZone 6,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2007,ClimateZone 6,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2007,ClimateZone 6,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 6,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2007,ClimateZone 6,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 6,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2007,ClimateZone 6,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2007,ClimateZone 6,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 6,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.45 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,Skylight,Plastic with Curb,Nonresidential,U 0.87 SHGC 0.71 Simple Glazing Skylight,,0,2,0.87,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,Skylight,Plastic with Curb,Residential,U 0.74 SHGC 0.65 Simple Glazing Skylight,,0,2,0.74,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,Skylight,Without Curb,Residential,U 0.58 SHGC 0.45 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 6,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 7,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2007,ClimateZone 7,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.042,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2007,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.45,, +90.1-2007,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,, +90.1-2007,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.45,, +90.1-2007,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.6 SHGC 0.45 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.45,, +90.1-2007,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 0.9 SHGC 0.45 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2007,ClimateZone 7,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.843,,,, +90.1-2007,ClimateZone 7,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2007,ClimateZone 7,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2007,ClimateZone 7,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 7,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2007,ClimateZone 7,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 7,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2007,ClimateZone 7,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, +90.1-2007,ClimateZone 7,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 7,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.68 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.64 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,Skylight,Plastic with Curb,Nonresidential,U 0.87 SHGC 0.77 Simple Glazing Skylight,,0,2,0.87,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,Skylight,Plastic with Curb,Residential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 7,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.68 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.36,, +90.1-2007,ClimateZone 7,Skylight,Without Curb,Residential,U 0.69 SHGC 0.64 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.19,, +90.1-2007,ClimateZone 7,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.16,, +90.1-2007,ClimateZone 8,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 8,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.072,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2007,ClimateZone 8,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.036,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.052,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.036,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2007,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.45,, +90.1-2007,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,, +90.1-2007,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.45,, +90.1-2007,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.6 SHGC 0.45 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.45,, +90.1-2007,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 0.9 SHGC 0.45 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2007,ClimateZone 8,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2007,ClimateZone 8,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.51,,,, +90.1-2007,ClimateZone 8,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2007,ClimateZone 8,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 8,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2007,ClimateZone 8,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 8,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2007,ClimateZone 8,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.075,,, +90.1-2007,ClimateZone 8,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 8,Skylight,Glass with Curb,Nonresidential,U 0.98 SHGC 0.45 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.45 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,Skylight,Glass with Curb,Semiheated,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.34,, +90.1-2007,ClimateZone 8,Skylight,Plastic with Curb,Nonresidential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,0.27,, +90.1-2007,ClimateZone 8,Skylight,Plastic with Curb,Residential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,0.27,, +90.1-2007,ClimateZone 8,Skylight,Plastic with Curb,Semiheated,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,Skylight,Without Curb,Nonresidential,U 0.58 SHGC 0.45 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 8,Skylight,Without Curb,Residential,U 0.58 SHGC 0.36 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,0.36,, +90.1-2007,ClimateZone 8,Skylight,Without Curb,Semiheated,U 0.81 SHGC 0.65 Simple Glazing Skylight,,0,2,0.81,TRUE,TRUE,,,0.19,, +90.1-2007,ClimateZone 1,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,1.18,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2007,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 1,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2007,ClimateZone 1,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 1,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2007,ClimateZone 1,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 1,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2007,ClimateZone 1,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 1,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 1,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 1,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 1,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.49 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.49,, +90.1-2007,ClimateZone 1,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.49,, +90.1-2007,ClimateZone 1,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.39 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.39,, +90.1-2007,ClimateZone 1,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.34 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 1,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.77,, +90.1-2007,ClimateZone 1,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.77,, +90.1-2007,ClimateZone 1,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.62,, +90.1-2007,ClimateZone 1,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 1,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.065,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.063,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.065,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.167,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2010,ClimateZone 1,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.093,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 2,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2010,ClimateZone 2,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.093,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.093,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2010,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.7 SHGC 0.25 Simple Glazing Window,,,,0.7,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.7 SHGC 0.25 Simple Glazing Window,,,,0.7,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 2,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2010,ClimateZone 2,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2010,ClimateZone 2,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2010,ClimateZone 2,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 2,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 2,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 2,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 2,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 2,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 2,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 2,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.27 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.27,, +90.1-2010,ClimateZone 2,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.27,, +90.1-2010,ClimateZone 2,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.36,, +90.1-2010,ClimateZone 2,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, +90.1-2010,ClimateZone 2,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.19,, +90.1-2010,ClimateZone 2,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 2,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 3,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2010,ClimateZone 3,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2010,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 3,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 3,ExteriorWindow,Metal framing (all other),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.9 SHGC 0.25 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 3,GlassDoor,Metal framing (entrance door),Residential,U 0.9 SHGC 0.25 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 3,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,GroundContactFloor,Unheated,Nonresidential,Smallhotel 2010 Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 3,GroundContactFloor,Heated,Nonresidential,Smallhotel 2010 Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2010,ClimateZone 3,GroundContactFloor,Unheated,Residential,Smallhotel 2010 Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 3,GroundContactFloor,Heated,Residential,Smallhotel 2010 Slab Floor,,,,,TRUE,TRUE,0.09,,,, +90.1-2010,ClimateZone 3,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 3,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2010,ClimateZone 3,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 3,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 3,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 3,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 3,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.39 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.39,, +90.1-2010,ClimateZone 3,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.36 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.36,, +90.1-2010,ClimateZone 3,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.19,, +90.1-2010,ClimateZone 3,Skylight,Plastic with Curb,Nonresidential,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,Skylight,Plastic with Curb,Residential,U 1.30 SHGC 0.27 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 3,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.65,, +90.1-2010,ClimateZone 3,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.39 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.27,, +90.1-2010,ClimateZone 3,Skylight,Without Curb,Residential,U 0.69 SHGC 0.36 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.27,, +90.1-2010,ClimateZone 3,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 4,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2010,ClimateZone 4,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2010,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.4 SHGC 0.4 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.4 SHGC 0.4 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.85 SHGC 0.4 Simple Glazing Window,,,,0.85,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.85 SHGC 0.4 Simple Glazing Window,,,,0.85,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 4,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2010,ClimateZone 4,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, +90.1-2010,ClimateZone 4,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2010,ClimateZone 4,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 4,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2010,ClimateZone 4,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 4,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 4,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2010,ClimateZone 4,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 4,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.36 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.39,, +90.1-2010,ClimateZone 4,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.36 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.36,, +90.1-2010,ClimateZone 4,Skylight,Plastic with Curb,Nonresidential,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.19,, +90.1-2010,ClimateZone 4,Skylight,Plastic with Curb,Residential,U 1.30 SHGC 0.62 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 4,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.49,, +90.1-2010,ClimateZone 4,Skylight,Without Curb,Residential,U 0.58 SHGC 0.36 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,0.36,, +90.1-2010,ClimateZone 4,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.19,, +90.1-2010,ClimateZone 5,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 5,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.119,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.083,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2010,ClimateZone 5,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.069,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.069,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2010,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 5,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2010,ClimateZone 5,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, +90.1-2010,ClimateZone 5,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2010,ClimateZone 5,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 5,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2010,ClimateZone 5,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 5,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2010,ClimateZone 5,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2010,ClimateZone 5,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 5,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.45 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.65 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.65,, +90.1-2010,ClimateZone 5,Skylight,Plastic with Curb,Nonresidential,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,0.62,, +90.1-2010,ClimateZone 5,Skylight,Plastic with Curb,Residential,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,0.27,, +90.1-2010,ClimateZone 5,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 5,Skylight,Without Curb,Residential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.49,, +90.1-2010,ClimateZone 5,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.36,, +90.1-2010,ClimateZone 6,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 6,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.072,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2010,ClimateZone 6,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.069,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.069,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2010,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.6 SHGC 0.45 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, +90.1-2010,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 0.9 SHGC 0.45 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, +90.1-2010,ClimateZone 6,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2010,ClimateZone 6,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2010,ClimateZone 6,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2010,ClimateZone 6,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 6,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2010,ClimateZone 6,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 6,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2010,ClimateZone 6,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2010,ClimateZone 6,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 6,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.19,, +90.1-2010,ClimateZone 6,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.45 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,Skylight,Plastic with Curb,Nonresidential,U 0.87 SHGC 0.71 Simple Glazing Skylight,,0,2,0.87,TRUE,TRUE,,,0.49,, +90.1-2010,ClimateZone 6,Skylight,Plastic with Curb,Residential,U 0.74 SHGC 0.65 Simple Glazing Skylight,,0,2,0.74,TRUE,TRUE,,,0.49,, +90.1-2010,ClimateZone 6,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.39,, +90.1-2010,ClimateZone 6,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,Skylight,Without Curb,Residential,U 0.58 SHGC 0.45 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 6,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.77,, +90.1-2010,ClimateZone 7,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 7,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.072,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2010,ClimateZone 7,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.042,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2010,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.45,, +90.1-2010,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,, +90.1-2010,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.45,, +90.1-2010,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.6 SHGC 0.45 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.45,, +90.1-2010,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 0.9 SHGC 0.45 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2010,ClimateZone 7,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.843,,,, +90.1-2010,ClimateZone 7,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2010,ClimateZone 7,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2010,ClimateZone 7,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 7,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2010,ClimateZone 7,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 7,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2010,ClimateZone 7,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, +90.1-2010,ClimateZone 7,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 7,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.68 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.77,, +90.1-2010,ClimateZone 7,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.64 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.62,, +90.1-2010,ClimateZone 7,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,Skylight,Plastic with Curb,Nonresidential,U 0.87 SHGC 0.77 Simple Glazing Skylight,,0,2,0.87,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,Skylight,Plastic with Curb,Residential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,0.49,, +90.1-2010,ClimateZone 7,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.49,, +90.1-2010,ClimateZone 7,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.68 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.39,, +90.1-2010,ClimateZone 7,Skylight,Without Curb,Residential,U 0.69 SHGC 0.64 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 7,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 8,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.035,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.035,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2010,ClimateZone 8,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.036,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.052,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.036,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2010,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.45,, +90.1-2010,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,, +90.1-2010,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.45,, +90.1-2010,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.6 SHGC 0.45 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.45,, +90.1-2010,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 0.9 SHGC 0.45 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2010,ClimateZone 8,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2010,ClimateZone 8,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.51,,,, +90.1-2010,ClimateZone 8,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2010,ClimateZone 8,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 8,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2010,ClimateZone 8,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 8,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2010,ClimateZone 8,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.075,,, +90.1-2010,ClimateZone 8,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 8,Skylight,Glass with Curb,Nonresidential,U 0.98 SHGC 0.49 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.49,, +90.1-2010,ClimateZone 8,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.46 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.46,, +90.1-2010,ClimateZone 8,Skylight,Glass with Curb,Semiheated,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.36,, +90.1-2010,ClimateZone 8,Skylight,Plastic with Curb,Nonresidential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,Skylight,Plastic with Curb,Residential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 8,Skylight,Plastic with Curb,Semiheated,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,0.71,, +90.1-2010,ClimateZone 8,Skylight,Without Curb,Nonresidential,U 0.58 SHGC 0.65 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,0.65,, +90.1-2010,ClimateZone 8,Skylight,Without Curb,Residential,U 0.58 SHGC 0.55 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,0.55,, +90.1-2010,ClimateZone 8,Skylight,Without Curb,Semiheated,U 0.81 SHGC 0.65 Simple Glazing Skylight,,0,2,0.81,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.093,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2010,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 1,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 1,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2010,ClimateZone 1,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 1,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2010,ClimateZone 1,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 1,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2010,ClimateZone 1,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 1,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 1,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 1,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 1,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.19,, +90.1-2010,ClimateZone 1,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.34 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.36,, +90.1-2010,ClimateZone 1,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, +90.1-2010,ClimateZone 1,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, +90.1-2010,ClimateZone 1,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 1,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.39,, +90.1-2013,ClimateZone 1,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 1,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.1156,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2013,ClimateZone 1,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 2,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.096,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2013,ClimateZone 2,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2013,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.4 SHGC 0.25 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.83 SHGC 0.25 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 0.4 SHGC 0.25 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 0.77 SHGC 0.25 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.93 SHGC 0.45 Simple Glazing Window,,,,0.93,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 0.83 SHGC 0.45 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 2,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2013,ClimateZone 2,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 2,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2013,ClimateZone 2,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 2,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2013,ClimateZone 2,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 2,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2013,ClimateZone 2,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2013,ClimateZone 2,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2013,ClimateZone 2,Skylight,Glass with Curb,Nonresidential,U 0.65 SHGC 0.45 Simple Glazing Skylight,,0,2,0.65,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,Skylight,Glass with Curb,Residential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,0,2,0.65,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,Skylight,Glass with Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,0.77,, +90.1-2013,ClimateZone 2,Skylight,Plastic with Curb,Nonresidential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,0,2,0.65,TRUE,TRUE,,,0.77,, +90.1-2013,ClimateZone 2,Skylight,Plastic with Curb,Residential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,0,2,0.65,TRUE,TRUE,,,0.77,, +90.1-2013,ClimateZone 2,Skylight,Plastic with Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,Skylight,Without Curb,Nonresidential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,0,2,0.65,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 2,Skylight,Without Curb,Residential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,0,2,0.65,TRUE,TRUE,,,0.68,, +90.1-2013,ClimateZone 2,Skylight,Without Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,0.64,, +90.1-2013,ClimateZone 3,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 3,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.119,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.096,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2013,ClimateZone 3,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.077,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.072,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2013,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.25 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 3,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.25 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.25 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 3,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.25 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.87 SHGC 0.45 Simple Glazing Window,,,,0.87,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 3,GlassDoor,Metal framing (entrance door),Residential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 3,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 3,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2013,ClimateZone 3,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, +90.1-2013,ClimateZone 3,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2013,ClimateZone 3,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 3,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2013,ClimateZone 3,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 3,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2013,ClimateZone 3,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2013,ClimateZone 3,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2013,ClimateZone 3,Skylight,Glass with Curb,Nonresidential,U 0.55 SHGC 0.64 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,0.64,, +90.1-2013,ClimateZone 3,Skylight,Glass with Curb,Residential,U 0.55 SHGC 0.45 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,Skylight,Glass with Curb,Semiheated,U 1.70 SHGC 0.36 Simple Glazing Skylight,,0,2,1.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,Skylight,Plastic with Curb,Nonresidential,U 0.55 SHGC 0.45 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,Skylight,Plastic with Curb,Residential,U 0.55 SHGC 0.45 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,Skylight,Plastic with Curb,Semiheated,U 1.70 SHGC 0.36 Simple Glazing Skylight,,0,2,1.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,Skylight,Without Curb,Nonresidential,U 0.55 SHGC 0.45 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,Skylight,Without Curb,Residential,U 0.55 SHGC 0.45 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 3,Skylight,Without Curb,Semiheated,U 1.70 SHGC 0.36 Simple Glazing Skylight,,0,2,1.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 4,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.082,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2013,ClimateZone 4,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.06,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2013,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.42 SHGC 0.4 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.42 SHGC 0.4 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.4 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.51 SHGC 0.45 Simple Glazing Window,,,,0.51,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.73 SHGC 0.45 Simple Glazing Window,,,,0.73,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.4 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 0.81 SHGC 0.45 Simple Glazing Window,,,,0.81,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2013,ClimateZone 4,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.843,,,, +90.1-2013,ClimateZone 4,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2013,ClimateZone 4,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2013,ClimateZone 4,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 4,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2013,ClimateZone 4,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 4,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2013,ClimateZone 4,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, +90.1-2013,ClimateZone 4,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2013,ClimateZone 4,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,Skylight,Glass with Curb,Semiheated,U 1.15 SHGC 0.77 Simple Glazing Skylight,,0,2,1.15,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,Skylight,Plastic with Curb,Semiheated,U 1.15 SHGC 0.77 Simple Glazing Skylight,,0,2,1.15,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,Skylight,Without Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 4,Skylight,Without Curb,Semiheated,U 1.15 SHGC 0.77 Simple Glazing Skylight,,0,2,1.15,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 5,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.082,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2013,ClimateZone 5,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.055,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.055,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2013,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.32 SHGC 0.4 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.42 SHGC 0.4 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.32 SHGC 0.4 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.42 SHGC 0.4 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.4 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.62 SHGC 0.45 Simple Glazing Window,,,,0.62,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.4 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 0.7 SHGC 0.45 Simple Glazing Window,,,,0.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2013,ClimateZone 5,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2013,ClimateZone 5,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.51,,,, +90.1-2013,ClimateZone 5,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2013,ClimateZone 5,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 5,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2013,ClimateZone 5,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 5,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2013,ClimateZone 5,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, +90.1-2013,ClimateZone 5,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2013,ClimateZone 5,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.36 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.36,, +90.1-2013,ClimateZone 5,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.19 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.19,, +90.1-2013,ClimateZone 5,Skylight,Glass with Curb,Semiheated,U 0.98 SHGC 0.45 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.34 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.34,, +90.1-2013,ClimateZone 5,Skylight,Plastic with Curb,Semiheated,U 0.98 SHGC 0.27 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.27,, +90.1-2013,ClimateZone 5,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,Skylight,Without Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 5,Skylight,Without Curb,Semiheated,U 0.98 SHGC 0.36 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.36,, +90.1-2013,ClimateZone 6,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 6,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.031,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.06,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2013,ClimateZone 6,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2013,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.32 SHGC 0.4 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.42 SHGC 0.4 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.4 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.32 SHGC 0.4 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.42 SHGC 0.4 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.4 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.51 SHGC 0.45 Simple Glazing Window,,,,0.51,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2013,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 0.59 SHGC 0.45 Simple Glazing Window,,,,0.59,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.51,,,, +90.1-2013,ClimateZone 6,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2013,ClimateZone 6,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.434,,,, +90.1-2013,ClimateZone 6,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.671,,,, +90.1-2013,ClimateZone 6,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 6,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2013,ClimateZone 6,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 6,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, +90.1-2013,ClimateZone 6,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2013,ClimateZone 6,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2013,ClimateZone 6,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.19 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.19,, +90.1-2013,ClimateZone 6,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,Skylight,Glass with Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.36 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.36,, +90.1-2013,ClimateZone 6,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.19 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.19,, +90.1-2013,ClimateZone 6,Skylight,Plastic with Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,0.19,, +90.1-2013,ClimateZone 6,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,Skylight,Without Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 6,Skylight,Without Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,0.39,, +90.1-2013,ClimateZone 7,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.042,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.042,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.27,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 7,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.039,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2013,ClimateZone 7,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.044,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.044,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.042,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.072,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2013,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.51,,,, +90.1-2013,ClimateZone 7,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.671,,,, +90.1-2013,ClimateZone 7,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.434,,,, +90.1-2013,ClimateZone 7,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.671,,,, +90.1-2013,ClimateZone 7,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 7,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2013,ClimateZone 7,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 7,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2013,ClimateZone 7,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2013,ClimateZone 7,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2013,ClimateZone 7,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.27 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.27,, +90.1-2013,ClimateZone 7,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.27 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.27,, +90.1-2013,ClimateZone 7,Skylight,Glass with Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.36 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.36,, +90.1-2013,ClimateZone 7,Skylight,Plastic with Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,0.19,, +90.1-2013,ClimateZone 7,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.19 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.19,, +90.1-2013,ClimateZone 7,Skylight,Without Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 7,Skylight,Without Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 8,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.026,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.026,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.039,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2013,ClimateZone 8,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.048,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.039,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.032,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.048,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.039,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.032,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.06,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2013,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, +90.1-2013,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.434,,,, +90.1-2013,ClimateZone 8,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.671,,,, +90.1-2013,ClimateZone 8,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.424,,,, +90.1-2013,ClimateZone 8,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.373,,,, +90.1-2013,ClimateZone 8,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, +90.1-2013,ClimateZone 8,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2013,ClimateZone 8,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 8,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2013,ClimateZone 8,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2013,ClimateZone 8,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2013,ClimateZone 8,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.39 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.39,, +90.1-2013,ClimateZone 8,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.36 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.36,, +90.1-2013,ClimateZone 8,Skylight,Glass with Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.65 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.65,, +90.1-2013,ClimateZone 8,Skylight,Plastic with Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,0.27,, +90.1-2013,ClimateZone 8,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,Skylight,Without Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 8,Skylight,Without Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,0.39,, +90.1-2013,ClimateZone 1,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,1151,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2013,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.93 SHGC 0.25 Simple Glazing Window,,,,0.93,TRUE,TRUE,,,0.25,, +90.1-2013,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2013,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,, +90.1-2013,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2013,ClimateZone 1,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 1,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2013,ClimateZone 1,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 1,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2013,ClimateZone 1,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 1,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2013,ClimateZone 1,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 1,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2013,ClimateZone 1,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2013,ClimateZone 1,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2013,ClimateZone 1,Skylight,Glass with Curb,Nonresidential,U 0.75 SHGC 0.45 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,Skylight,Glass with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.49,, +90.1-2013,ClimateZone 1,Skylight,Glass with Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,0.49,, +90.1-2013,ClimateZone 1,Skylight,Plastic with Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.39,, +90.1-2013,ClimateZone 1,Skylight,Plastic with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,Skylight,Plastic with Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 1,Skylight,Without Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.68,, +90.1-2013,ClimateZone 1,Skylight,Without Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.64,, +90.1-2013,ClimateZone 1,Skylight,Without Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,0.64,, +90.1-2016,ClimateZone 1,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 1,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 1,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 1,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 1,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 1,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.1156,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2016,ClimateZone 1,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 2,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 2,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 2,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 2,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 2,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.096,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2016,ClimateZone 2,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2016,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.37 SHGC 0.25 Simple Glazing Window,,,,0.37,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.54 SHGC 0.25 Simple Glazing Window,,,,0.54,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.83 SHGC 0.25 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 0.37 SHGC 0.25 Simple Glazing Window,,,,0.37,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.54 SHGC 0.25 Simple Glazing Window,,,,0.54,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 0.77 SHGC 0.25 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.93 SHGC 0.45 Simple Glazing Window,,,,0.93,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 0.83 SHGC 0.45 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 2,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 2,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2016,ClimateZone 2,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 2,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2016,ClimateZone 2,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 2,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2016,ClimateZone 2,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 2,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2016,ClimateZone 2,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2016,ClimateZone 2,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2016,ClimateZone 2,Skylight,Glass with Curb,Nonresidential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 2,Skylight,Glass with Curb,Residential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 2,Skylight,Glass with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, +90.1-2016,ClimateZone 2,Skylight,Plastic with Curb,Nonresidential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 2,Skylight,Plastic with Curb,Residential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 2,Skylight,Plastic with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, +90.1-2016,ClimateZone 2,Skylight,Without Curb,Nonresidential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 2,Skylight,Without Curb,Residential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 2,Skylight,Without Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, +90.1-2016,ClimateZone 3,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 3,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 3,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 3,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 3,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 3,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 3,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 3,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.119,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.096,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2016,ClimateZone 3,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.077,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.072,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2016,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.33 SHGC 0.25 Simple Glazing Window,,,,0.33,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 3,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.25 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Residential,U 0.33 SHGC 0.25 Simple Glazing Window,,,,0.33,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 3,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.25 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.87 SHGC 0.45 Simple Glazing Window,,,,0.87,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 3,GlassDoor,Metal framing (entrance door),Residential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 3,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 3,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2016,ClimateZone 3,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, +90.1-2016,ClimateZone 3,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2016,ClimateZone 3,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 3,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2016,ClimateZone 3,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 3,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2016,ClimateZone 3,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2016,ClimateZone 3,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2016,ClimateZone 3,Skylight,Glass with Curb,Nonresidential,U 0.55 SHGC 0.35 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 3,Skylight,Glass with Curb,Residential,U 0.55 SHGC 0.35 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 3,Skylight,Glass with Curb,Semiheated,U 1.7 SHGC 0.55 Simple Glazing Skylight,,,,1.7,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,Skylight,Plastic with Curb,Nonresidential,U 0.55 SHGC 0.35 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 3,Skylight,Plastic with Curb,Residential,U 0.55 SHGC 0.35 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 3,Skylight,Plastic with Curb,Semiheated,U 1.7 SHGC 0.55 Simple Glazing Skylight,,,,1.7,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 3,Skylight,Without Curb,Nonresidential,U 0.55 SHGC 0.35 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 3,Skylight,Without Curb,Residential,U 0.55 SHGC 0.35 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 3,Skylight,Without Curb,Semiheated,U 1.7 SHGC 0.55 Simple Glazing Skylight,,,,1.7,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 4,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 4,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 4,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 4,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 4,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 4,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 4,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.082,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2016,ClimateZone 4,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.06,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2016,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.31 SHGC 0.36 Simple Glazing Window,,,,0.31,TRUE,TRUE,,,0.36,1.1, +90.1-2016,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.38 SHGC 0.36 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.36,1.1, +90.1-2016,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.31 SHGC 0.36 Simple Glazing Window,,,,0.31,TRUE,TRUE,,,0.36,1.1, +90.1-2016,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.38 SHGC 0.36 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.36,1.1, +90.1-2016,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.36 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.36,1.1, +90.1-2016,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.51 SHGC 0.45 Simple Glazing Window,,,,0.51,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.73 SHGC 0.45 Simple Glazing Window,,,,0.73,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.68 SHGC 0.36 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.36,1.1, +90.1-2016,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2016,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2016,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 0.81 SHGC 0.45 Simple Glazing Window,,,,0.81,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2016,ClimateZone 4,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.843,,,, +90.1-2016,ClimateZone 4,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2016,ClimateZone 4,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2016,ClimateZone 4,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 4,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2016,ClimateZone 4,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 4,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2016,ClimateZone 4,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, +90.1-2016,ClimateZone 4,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2016,ClimateZone 4,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 4,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 4,Skylight,Glass with Curb,Semiheated,U 1.15 SHGC 0.55 Simple Glazing Skylight,,,,1.15,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 4,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 4,Skylight,Plastic with Curb,Semiheated,U 1.15 SHGC 0.55 Simple Glazing Skylight,,,,1.15,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 4,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 4,Skylight,Without Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 4,Skylight,Without Curb,Semiheated,U 1.15 SHGC 0.55 Simple Glazing Skylight,,,,1.15,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 5,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 5,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 5,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 5,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 5,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 5,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 5,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.082,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2016,ClimateZone 5,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.055,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.055,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2016,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.31 SHGC 0.38 Simple Glazing Window,,,,0.31,TRUE,TRUE,,,0.38,1.1, +90.1-2016,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.38 SHGC 0.38 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.38,1.1, +90.1-2016,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.31 SHGC 0.38 Simple Glazing Window,,,,0.31,TRUE,TRUE,,,0.38,1.1, +90.1-2016,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.38 SHGC 0.38 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.38,1.1, +90.1-2016,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.38 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.38,1.1, +90.1-2016,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.62 SHGC 0.45 Simple Glazing Window,,,,0.62,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.68 SHGC 0.38 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.38,1.1, +90.1-2016,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2016,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2016,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 0.7 SHGC 0.45 Simple Glazing Window,,,,0.7,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2016,ClimateZone 5,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2016,ClimateZone 5,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.51,,,, +90.1-2016,ClimateZone 5,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2016,ClimateZone 5,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 5,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2016,ClimateZone 5,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 5,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2016,ClimateZone 5,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, +90.1-2016,ClimateZone 5,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2016,ClimateZone 5,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 5,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 5,Skylight,Glass with Curb,Semiheated,U 0.98 SHGC 0.55 Simple Glazing Skylight,,,,0.98,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 5,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 5,Skylight,Plastic with Curb,Semiheated,U 0.98 SHGC 0.55 Simple Glazing Skylight,,,,0.98,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 5,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 5,Skylight,Without Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 5,Skylight,Without Curb,Semiheated,U 0.98 SHGC 0.55 Simple Glazing Skylight,,,,0.98,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 6,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 6,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 6,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 6,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 6,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 6,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 6,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.031,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.06,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2016,ClimateZone 6,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2016,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.3 SHGC 0.4 Simple Glazing Window,,,,0.3,TRUE,TRUE,,,0.4,1.1, +90.1-2016,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.36 SHGC 0.4 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.4,1.1, +90.1-2016,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.68 SHGC 0.4 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.4,1.1, +90.1-2016,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.3 SHGC 0.4 Simple Glazing Window,,,,0.3,TRUE,TRUE,,,0.4,1.1, +90.1-2016,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.36 SHGC 0.4 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.4,1.1, +90.1-2016,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.4 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.4,1.1, +90.1-2016,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.51 SHGC 0.45 Simple Glazing Window,,,,0.51,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2016,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2016,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 0.59 SHGC 0.45 Simple Glazing Window,,,,0.59,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.51,,,, +90.1-2016,ClimateZone 6,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2016,ClimateZone 6,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.434,,,, +90.1-2016,ClimateZone 6,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.671,,,, +90.1-2016,ClimateZone 6,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 6,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2016,ClimateZone 6,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 6,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, +90.1-2016,ClimateZone 6,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2016,ClimateZone 6,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2016,ClimateZone 6,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 6,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 6,Skylight,Glass with Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 6,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 6,Skylight,Plastic with Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 6,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 6,Skylight,Without Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2016,ClimateZone 6,Skylight,Without Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 7,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 7,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 7,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 7,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 7,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 7,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.042,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.042,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.27,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 7,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.039,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2016,ClimateZone 7,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.044,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.044,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.042,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.072,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2016,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.28 SHGC 0.45 Simple Glazing Window,,,,0.28,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.33 SHGC 0.45 Simple Glazing Window,,,,0.33,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.28 SHGC 0.45 Simple Glazing Window,,,,0.28,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.33 SHGC 0.45 Simple Glazing Window,,,,0.33,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.51,,,, +90.1-2016,ClimateZone 7,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.671,,,, +90.1-2016,ClimateZone 7,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.434,,,, +90.1-2016,ClimateZone 7,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.671,,,, +90.1-2016,ClimateZone 7,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 7,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2016,ClimateZone 7,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 7,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2016,ClimateZone 7,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2016,ClimateZone 7,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2016,ClimateZone 7,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.55 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.55 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,Skylight,Glass with Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.55 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.55 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,Skylight,Plastic with Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.55 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,Skylight,Without Curb,Residential,U 0.5 SHGC 0.55 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 7,Skylight,Without Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 8,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 8,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 8,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 8,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 8,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 8,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 8,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.026,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.026,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.039,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2016,ClimateZone 8,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.048,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.039,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.048,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.039,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.06,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2016,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.25 SHGC 0.45 Simple Glazing Window,,,,0.25,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.29 SHGC 0.45 Simple Glazing Window,,,,0.29,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.25 SHGC 0.45 Simple Glazing Window,,,,0.25,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.29 SHGC 0.45 Simple Glazing Window,,,,0.29,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, +90.1-2016,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.434,,,, +90.1-2016,ClimateZone 8,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.671,,,, +90.1-2016,ClimateZone 8,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.424,,,, +90.1-2016,ClimateZone 8,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.373,,,, +90.1-2016,ClimateZone 8,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, +90.1-2016,ClimateZone 8,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2016,ClimateZone 8,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 8,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2016,ClimateZone 8,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2016,ClimateZone 8,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2016,ClimateZone 8,Skylight,Glass with Curb,Nonresidential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,Skylight,Glass with Curb,Residential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,Skylight,Glass with Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,Skylight,Plastic with Curb,Nonresidential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,Skylight,Plastic with Curb,Residential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,Skylight,Plastic with Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,Skylight,Without Curb,Nonresidential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,Skylight,Without Curb,Residential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 8,Skylight,Without Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,1151,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2016,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.93 SHGC 0.45 Simple Glazing Window,,,,0.93,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.1 SHGC 0.45 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2016,ClimateZone 1,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 1,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2016,ClimateZone 1,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 1,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2016,ClimateZone 1,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 1,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2016,ClimateZone 1,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 1,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2016,ClimateZone 1,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2016,ClimateZone 1,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2016,ClimateZone 1,Skylight,Glass with Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 1,Skylight,Glass with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 1,Skylight,Glass with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, +90.1-2016,ClimateZone 1,Skylight,Plastic with Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 1,Skylight,Plastic with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 1,Skylight,Plastic with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, +90.1-2016,ClimateZone 1,Skylight,Without Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 1,Skylight,Without Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 1,Skylight,Without Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, +90.1-2019,ClimateZone 1,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 1,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 1,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 1,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 1,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 1,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.1156,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2019,ClimateZone 1,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 2,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 2,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 2,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 2,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 2,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.096,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2019,ClimateZone 2,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2019,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1,Fixed +90.1-2019,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1,Fixed +90.1-2019,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.23 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.23,1.1,Entrance door +90.1-2019,ClimateZone 2,ExteriorWindow,Fixed,Nonresidential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1, +90.1-2019,ClimateZone 2,ExteriorWindow,Operable,Nonresidential,U 0.6 SHGC 0.23 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.23,1.1, +90.1-2019,ClimateZone 2,ExteriorWindow,Entrance door,Nonresidential,U 0.77 SHGC 0.23 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.23,1.1, +90.1-2019,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1,Fixed +90.1-2019,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1,Fixed +90.1-2019,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 0.77 SHGC 0.23 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.23,1.1,Entrance door +90.1-2019,ClimateZone 2,ExteriorWindow,Fixed,Residential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1, +90.1-2019,ClimateZone 2,ExteriorWindow,Operable,Residential,U 0.6 SHGC 0.23 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.23,1.1, +90.1-2019,ClimateZone 2,ExteriorWindow,Entrance door,Residential,U 0.77 SHGC 0.23 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.23,1.1, +90.1-2019,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,,Entrance door +90.1-2019,ClimateZone 2,ExteriorWindow,Fixed,Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorWindow,Operable,Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,ExteriorWindow,Entrance door,Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2019,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2019,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 2,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 2,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2019,ClimateZone 2,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 2,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2019,ClimateZone 2,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 2,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2019,ClimateZone 2,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 2,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2019,ClimateZone 2,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2019,ClimateZone 2,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2019,ClimateZone 2,Skylight,Glass with Curb,Nonresidential,U 0.65 SHGC 0.3 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 2,Skylight,Glass with Curb,Residential,U 0.65 SHGC 0.3 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 2,Skylight,Glass with Curb,Semiheated,U 0.9 SHGC 0.55 Simple Glazing Skylight,,,,0.9,TRUE,TRUE,,,0.55,, +90.1-2019,ClimateZone 2,Skylight,Plastic with Curb,Nonresidential,U 0.65 SHGC 0.3 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 2,Skylight,Plastic with Curb,Residential,U 0.65 SHGC 0.3 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 2,Skylight,Plastic with Curb,Semiheated,U 0.9 SHGC 0.55 Simple Glazing Skylight,,,,0.9,TRUE,TRUE,,,0.55,, +90.1-2019,ClimateZone 2,Skylight,Without Curb,Nonresidential,U 0.65 SHGC 0.3 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 2,Skylight,Without Curb,Residential,U 0.65 SHGC 0.3 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 2,Skylight,Without Curb,Semiheated,U 0.9 SHGC 0.55 Simple Glazing Skylight,,,,0.9,TRUE,TRUE,,,0.55,, +90.1-2019,ClimateZone 3,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 3,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 3,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 3,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 3,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 3,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 3,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 3,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.119,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.096,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2019,ClimateZone 3,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.077,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.072,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2019,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.42 SHGC 0.25 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.25,1.1,Fixed +90.1-2019,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.42 SHGC 0.25 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.25,1.1,Fixed +90.1-2019,ClimateZone 3,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.68 SHGC 0.23 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.23,1.1,Entrance door +90.1-2019,ClimateZone 3,ExteriorWindow,Fixed,Nonresidential,U 0.42 SHGC 0.25 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.25,1.1, +90.1-2019,ClimateZone 3,ExteriorWindow,Operable,Nonresidential,U 0.54 SHGC 0.23 Simple Glazing Window,,,,0.54,TRUE,TRUE,,,0.23,1.1, +90.1-2019,ClimateZone 3,ExteriorWindow,Entrance door,Nonresidential,U 0.68 SHGC 0.23 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.23,1.1, +90.1-2019,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Residential,U 0.42 SHGC 0.25 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.25,1.1,Fixed +90.1-2019,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.42 SHGC 0.25 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.25,1.1,Fixed +90.1-2019,ClimateZone 3,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.23 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.23,1.1,Entrance door +90.1-2019,ClimateZone 3,ExteriorWindow,Fixed,Residential,U 0.42 SHGC 0.25 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.25,1.1, +90.1-2019,ClimateZone 3,ExteriorWindow,Operable,Residential,U 0.54 SHGC 0.23 Simple Glazing Window,,,,0.54,TRUE,TRUE,,,0.23,1.1, +90.1-2019,ClimateZone 3,ExteriorWindow,Entrance door,Residential,U 0.68 SHGC 0.23 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.23,1.1, +90.1-2019,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 3,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,,Entrance door +90.1-2019,ClimateZone 3,ExteriorWindow,Fixed,Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorWindow,Operable,Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,ExteriorWindow,Entrance door,Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,1.1, +90.1-2019,ClimateZone 3,GlassDoor,Metal framing (entrance door),Residential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,1.1, +90.1-2019,ClimateZone 3,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 3,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2019,ClimateZone 3,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, +90.1-2019,ClimateZone 3,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2019,ClimateZone 3,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 3,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2019,ClimateZone 3,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 3,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2019,ClimateZone 3,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2019,ClimateZone 3,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2019,ClimateZone 3,Skylight,Glass with Curb,Nonresidential,U 0.55 SHGC 0.3 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 3,Skylight,Glass with Curb,Residential,U 0.55 SHGC 0.3 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 3,Skylight,Glass with Curb,Semiheated,U 0.9 SHGC 0.55 Simple Glazing Skylight,,,,0.9,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,Skylight,Plastic with Curb,Nonresidential,U 0.55 SHGC 0.3 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 3,Skylight,Plastic with Curb,Residential,U 0.55 SHGC 0.3 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 3,Skylight,Plastic with Curb,Semiheated,U 0.9 SHGC 0.55 Simple Glazing Skylight,,,,0.9,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 3,Skylight,Without Curb,Nonresidential,U 0.55 SHGC 0.3 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 3,Skylight,Without Curb,Residential,U 0.55 SHGC 0.3 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 3,Skylight,Without Curb,Semiheated,U 0.9 SHGC 0.55 Simple Glazing Skylight,,,,0.9,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 4,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 4,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 4,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 4,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 4,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 4,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 4,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.082,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2019,ClimateZone 4,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.06,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2019,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1,Fixed +90.1-2019,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1,Fixed +90.1-2019,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1,Fixed +90.1-2019,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1,Fixed +90.1-2019,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1,Entrance door +90.1-2019,ClimateZone 4,ExteriorWindow,Fixed,Residential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1, +90.1-2019,ClimateZone 4,ExteriorWindow,Operable,Residential,U 0.45 SHGC 0.33 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.33,1.1, +90.1-2019,ClimateZone 4,ExteriorWindow,Entrance door,Residential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1, +90.1-2019,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,,Entrance door +90.1-2019,ClimateZone 4,ExteriorWindow,Fixed,Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWindow,Operable,Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWindow,Entrance door,Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1,Entrance door +90.1-2019,ClimateZone 4,ExteriorWindow,Fixed,Nonresidential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1, +90.1-2019,ClimateZone 4,ExteriorWindow,Operable,Nonresidential,U 0.45 SHGC 0.33 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.33,1.1, +90.1-2019,ClimateZone 4,ExteriorWindow,Entrance door,Nonresidential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1, +90.1-2019,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2019,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2019,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 0.81 SHGC 0.45 Simple Glazing Window,,,,0.81,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2019,ClimateZone 4,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.843,,,, +90.1-2019,ClimateZone 4,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2019,ClimateZone 4,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2019,ClimateZone 4,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 4,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2019,ClimateZone 4,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 4,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2019,ClimateZone 4,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, +90.1-2019,ClimateZone 4,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2019,ClimateZone 4,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 4,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 4,Skylight,Glass with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 4,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 4,Skylight,Plastic with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 4,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 4,Skylight,Without Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 4,Skylight,Without Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 5,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 5,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 5,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 5,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 5,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 5,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 5,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.082,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2019,ClimateZone 5,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.055,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.055,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2019,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.36 SHGC 0.38 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.38,1.1,Fixed +90.1-2019,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.36 SHGC 0.38 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.38,1.1,Fixed +90.1-2019,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.36 SHGC 0.38 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.38,1.1,Fixed +90.1-2019,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.36 SHGC 0.38 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.38,1.1,Fixed +90.1-2019,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1,Entrance door +90.1-2019,ClimateZone 5,ExteriorWindow,Fixed,Residential,U 0.36 SHGC 0.38 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.38,1.1, +90.1-2019,ClimateZone 5,ExteriorWindow,Operable,Residential,U 0.45 SHGC 0.33 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.33,1.1, +90.1-2019,ClimateZone 5,ExteriorWindow,Entrance door,Residential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1, +90.1-2019,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,,Entrance door +90.1-2019,ClimateZone 5,ExteriorWindow,Fixed,Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWindow,Operable,Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWindow,Entrance door,Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1,Entrance door +90.1-2019,ClimateZone 5,ExteriorWindow,Fixed,Nonresidential,U 0.36 SHGC 0.38 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.38,1.1, +90.1-2019,ClimateZone 5,ExteriorWindow,Operable,Nonresidential,U 0.45 SHGC 0.33 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.33,1.1, +90.1-2019,ClimateZone 5,ExteriorWindow,Entrance door,Nonresidential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1, +90.1-2019,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2019,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2019,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 0.7 SHGC 0.45 Simple Glazing Window,,,,0.7,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.52,,,, +90.1-2019,ClimateZone 5,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2019,ClimateZone 5,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.51,,,, +90.1-2019,ClimateZone 5,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2019,ClimateZone 5,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 5,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, +90.1-2019,ClimateZone 5,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 5,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2019,ClimateZone 5,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, +90.1-2019,ClimateZone 5,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2019,ClimateZone 5,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 5,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 5,Skylight,Glass with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 5,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 5,Skylight,Plastic with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 5,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 5,Skylight,Without Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 5,Skylight,Without Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 6,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 6,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 6,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 6,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 6,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 6,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 6,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.031,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.06,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2019,ClimateZone 6,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2019,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.34 SHGC 0.38 Simple Glazing Window,,,,0.34,TRUE,TRUE,,,0.38,1.1,Fixed +90.1-2019,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.34 SHGC 0.38 Simple Glazing Window,,,,0.34,TRUE,TRUE,,,0.38,1.1,Fixed +90.1-2019,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.63 SHGC 0.34 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.34,1.1,Entrance door +90.1-2019,ClimateZone 6,ExteriorWindow,Fixed,Nonresidential,U 0.34 SHGC 0.38 Simple Glazing Window,,,,0.34,TRUE,TRUE,,,0.38,1.1, +90.1-2019,ClimateZone 6,ExteriorWindow,Operable,Nonresidential,U 0.42 SHGC 0.34 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.34,1.1, +90.1-2019,ClimateZone 6,ExteriorWindow,Entrance door,Nonresidential,U 0.63 SHGC 0.34 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.34,1.1, +90.1-2019,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.34 SHGC 0.38 Simple Glazing Window,,,,0.34,TRUE,TRUE,,,0.38,1.1,Fixed +90.1-2019,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.34 SHGC 0.38 Simple Glazing Window,,,,0.34,TRUE,TRUE,,,0.38,1.1,Fixed +90.1-2019,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.63 SHGC 0.34 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.34,1.1,Entrance door +90.1-2019,ClimateZone 6,ExteriorWindow,Fixed,Residential,U 0.34 SHGC 0.38 Simple Glazing Window,,,,0.34,TRUE,TRUE,,,0.38,1.1, +90.1-2019,ClimateZone 6,ExteriorWindow,Operable,Residential,U 0.42 SHGC 0.34 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.34,1.1, +90.1-2019,ClimateZone 6,ExteriorWindow,Entrance door,Residential,U 0.63 SHGC 0.34 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.34,1.1, +90.1-2019,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.39 SHGC 0.45 Simple Glazing Window,,,,0.39,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.39 SHGC 0.45 Simple Glazing Window,,,,0.39,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,,,Entrance door +90.1-2019,ClimateZone 6,ExteriorWindow,Fixed,Semiheated,U 0.39 SHGC 0.45 Simple Glazing Window,,,,0.39,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorWindow,Operable,Semiheated,U 0.48 SHGC 0.45 Simple Glazing Window,,,,0.48,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,ExteriorWindow,Entrance door,Semiheated,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2019,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, +90.1-2019,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 0.59 SHGC 0.45 Simple Glazing Window,,,,0.59,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.51,,,, +90.1-2019,ClimateZone 6,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.688,,,, +90.1-2019,ClimateZone 6,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.434,,,, +90.1-2019,ClimateZone 6,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.671,,,, +90.1-2019,ClimateZone 6,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 6,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2019,ClimateZone 6,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 6,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, +90.1-2019,ClimateZone 6,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2019,ClimateZone 6,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2019,ClimateZone 6,Skylight,Glass with Curb,Nonresidential,U 0.47 SHGC 0.4 Simple Glazing Skylight,,,,0.47,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 6,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 6,Skylight,Glass with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,Skylight,Plastic with Curb,Nonresidential,U 0.47 SHGC 0.4 Simple Glazing Skylight,,,,0.47,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 6,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 6,Skylight,Plastic with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 6,Skylight,Without Curb,Nonresidential,U 0.47 SHGC 0.4 Simple Glazing Skylight,,,,0.47,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 6,Skylight,Without Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, +90.1-2019,ClimateZone 6,Skylight,Without Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 7,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 7,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 7,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 7,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 7,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 7,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.042,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.042,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.27,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 7,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.039,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2019,ClimateZone 7,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.044,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.044,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.042,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.072,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2019,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.29 SHGC 0.4 Simple Glazing Window,,,,0.29,TRUE,TRUE,,,0.4,1.1,Fixed +90.1-2019,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.29 SHGC 0.4 Simple Glazing Window,,,,0.29,TRUE,TRUE,,,0.4,1.1,Fixed +90.1-2019,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1,Entrance door +90.1-2019,ClimateZone 7,ExteriorWindow,Fixed,Nonresidential,U 0.29 SHGC 0.4 Simple Glazing Window,,,,0.29,TRUE,TRUE,,,0.4,1.1, +90.1-2019,ClimateZone 7,ExteriorWindow,Operable,Nonresidential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1, +90.1-2019,ClimateZone 7,ExteriorWindow,Entrance door,Nonresidential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1, +90.1-2019,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.29 SHGC 0.4 Simple Glazing Window,,,,0.29,TRUE,TRUE,,,0.4,1.1,Fixed +90.1-2019,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.29 SHGC 0.4 Simple Glazing Window,,,,0.29,TRUE,TRUE,,,0.4,1.1,Fixed +90.1-2019,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1,Entrance door +90.1-2019,ClimateZone 7,ExteriorWindow,Fixed,Residential,U 0.26 SHGC 0.4 Simple Glazing Window,,,,0.26,TRUE,TRUE,,,0.4,1.1, +90.1-2019,ClimateZone 7,ExteriorWindow,Operable,Residential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1, +90.1-2019,ClimateZone 7,ExteriorWindow,Entrance door,Residential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1, +90.1-2019,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.36 SHGC 0.45 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.36 SHGC 0.45 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 0.63 SHGC 0.45 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,,,Entrance door +90.1-2019,ClimateZone 7,ExteriorWindow,Fixed,Semiheated,U 0.36 SHGC 0.45 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorWindow,Operable,Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,ExteriorWindow,Entrance door,Semiheated,U 0.63 SHGC 0.45 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, +90.1-2019,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, +90.1-2019,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.51,,,, +90.1-2019,ClimateZone 7,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.671,,,, +90.1-2019,ClimateZone 7,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.434,,,, +90.1-2019,ClimateZone 7,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.671,,,, +90.1-2019,ClimateZone 7,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 7,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2019,ClimateZone 7,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 7,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2019,ClimateZone 7,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2019,ClimateZone 7,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2019,ClimateZone 7,Skylight,Glass with Curb,Nonresidential,U 0.44 SHGC 0.55 Simple Glazing Skylight,,,,0.44,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,Skylight,Glass with Curb,Residential,U 0.44 SHGC 0.55 Simple Glazing Skylight,,,,0.44,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,Skylight,Glass with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,Skylight,Plastic with Curb,Nonresidential,U 0.44 SHGC 0.55 Simple Glazing Skylight,,,,0.44,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,Skylight,Plastic with Curb,Residential,U 0.44 SHGC 0.55 Simple Glazing Skylight,,,,0.44,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,Skylight,Plastic with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,Skylight,Without Curb,Nonresidential,U 0.44 SHGC 0.55 Simple Glazing Skylight,,,,0.44,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,Skylight,Without Curb,Residential,U 0.44 SHGC 0.55 Simple Glazing Skylight,,,,0.44,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 7,Skylight,Without Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 8,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 8,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 8,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 8,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 8,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 8,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.038,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 8,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.026,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.026,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.039,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2019,ClimateZone 8,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.048,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.039,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.048,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.039,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.06,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2019,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.26 SHGC 0.4 Simple Glazing Window,,,,0.26,TRUE,TRUE,,,0.4,1.1,Fixed +90.1-2019,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.26 SHGC 0.4 Simple Glazing Window,,,,0.26,TRUE,TRUE,,,0.4,1.1,Fixed +90.1-2019,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1,Entrance door +90.1-2019,ClimateZone 8,ExteriorWindow,Fixed,Nonresidential,U 0.26 SHGC 0.4 Simple Glazing Window,,,,0.26,TRUE,TRUE,,,0.4,1.1, +90.1-2019,ClimateZone 8,ExteriorWindow,Operable,Nonresidential,U 0.32 SHGC 0.36 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.36,1.1, +90.1-2019,ClimateZone 8,ExteriorWindow,Entrance door,Nonresidential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1, +90.1-2019,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.26 SHGC 0.4 Simple Glazing Window,,,,0.26,TRUE,TRUE,,,0.4,1.1,Fixed +90.1-2019,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.26 SHGC 0.4 Simple Glazing Window,,,,0.26,TRUE,TRUE,,,0.4,1.1,Fixed +90.1-2019,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1,Entrance door +90.1-2019,ClimateZone 8,ExteriorWindow,Fixed,Residential,U 0.26 SHGC 0.4 Simple Glazing Window,,,,0.26,TRUE,TRUE,,,0.4,1.1, +90.1-2019,ClimateZone 8,ExteriorWindow,Operable,Residential,U 0.32 SHGC 0.36 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.36,1.1, +90.1-2019,ClimateZone 8,ExteriorWindow,Entrance door,Residential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1, +90.1-2019,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.36 SHGC 0.45 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.36 SHGC 0.45 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 0.63 SHGC 0.45 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,,,Entrance door +90.1-2019,ClimateZone 8,ExteriorWindow,Fixed,Semiheated,U 0.36 SHGC 0.45 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorWindow,Operable,Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,ExteriorWindow,Metal framing (entrance door),Semiheated,U 0.63 SHGC 0.45 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, +90.1-2019,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, +90.1-2019,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.434,,,, +90.1-2019,ClimateZone 8,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.671,,,, +90.1-2019,ClimateZone 8,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.424,,,, +90.1-2019,ClimateZone 8,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.373,,,, +90.1-2019,ClimateZone 8,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, +90.1-2019,ClimateZone 8,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, +90.1-2019,ClimateZone 8,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 8,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2019,ClimateZone 8,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, +90.1-2019,ClimateZone 8,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, +90.1-2019,ClimateZone 8,Skylight,Glass with Curb,Nonresidential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,Skylight,Glass with Curb,Residential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,Skylight,Glass with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,Skylight,Plastic with Curb,Nonresidential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,Skylight,Plastic with Curb,Residential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,Skylight,Plastic with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,Skylight,Without Curb,Nonresidential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,Skylight,Without Curb,Residential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 8,Skylight,Without Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,1151,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2019,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.5 SHGC 0.23 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.23,1.1,Fixed +90.1-2019,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.5 SHGC 0.23 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.23,1.1,Fixed +90.1-2019,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.83 SHGC 0.21 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.21,1.1,Entrance door +90.1-2019,ClimateZone 1,ExteriorWindow,Fixed,Nonresidential,U 0.5 SHGC 0.23 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.23,1.1, +90.1-2019,ClimateZone 1,ExteriorWindow,Operable,Nonresidential,U 0.62 SHGC 0.21 Simple Glazing Window,,,,0.62,TRUE,TRUE,,,0.21,1.1, +90.1-2019,ClimateZone 1,ExteriorWindow,Entrance door,Nonresidential,U 0.83 SHGC 0.21 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.21,1.1, +90.1-2019,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 0.5 SHGC 0.23 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.23,1.1,Fixed +90.1-2019,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.5 SHGC 0.23 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.23,1.1,Fixed +90.1-2019,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 0.83 SHGC 0.21 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.21,1.1,Entrance door +90.1-2019,ClimateZone 1,ExteriorWindow,Fixed,Residential,U 0.5 SHGC 0.23 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.23,1.1, +90.1-2019,ClimateZone 1,ExteriorWindow,Operable,Residential,U 0.62 SHGC 0.21 Simple Glazing Window,,,,0.62,TRUE,TRUE,,,0.21,1.1, +90.1-2019,ClimateZone 1,ExteriorWindow,Entrance door,Residential,U 0.83 SHGC 0.21 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.21,1.1, +90.1-2019,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.1 SHGC 0.45 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,,,Entrance door +90.1-2019,ClimateZone 1,ExteriorWindow,Fixed,Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorWindow,Operable,Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,ExteriorWindow,Entrance door,Semiheated,U 1.1 SHGC 0.45 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2019,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2019,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2019,ClimateZone 1,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 1,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2019,ClimateZone 1,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 1,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2019,ClimateZone 1,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 1,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2019,ClimateZone 1,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 1,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2019,ClimateZone 1,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2019,ClimateZone 1,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2019,ClimateZone 1,Skylight,Glass with Curb,Nonresidential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 1,Skylight,Glass with Curb,Residential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 1,Skylight,Glass with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, +90.1-2019,ClimateZone 1,Skylight,Plastic with Curb,Nonresidential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 1,Skylight,Plastic with Curb,Residential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 1,Skylight,Plastic with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, +90.1-2019,ClimateZone 1,Skylight,Without Curb,Nonresidential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 1,Skylight,Without Curb,Residential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 1,Skylight,Without Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, +90.1-2016,ClimateZone 0,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 0,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 0,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 0,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2016,ClimateZone 0,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 0,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.032,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.115,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2016,ClimateZone 0,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2016,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.32 SHGC 0.22 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.22,1.1, +90.1-2016,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1, +90.1-2016,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.83 SHGC 0.22 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.22,1.1, +90.1-2016,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 0.32 SHGC 0.22 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.22,1.1, +90.1-2016,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1, +90.1-2016,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 0.83 SHGC 0.22 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.22,1.1, +90.1-2016,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.93 SHGC 0.45 Simple Glazing Window,,,,0.93,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.1 SHGC 0.45 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,,, +90.1-2016,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2016,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2016,ClimateZone 0,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 0,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2016,ClimateZone 0,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 0,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2016,ClimateZone 0,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2016,ClimateZone 0,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2016,ClimateZone 0,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2016,ClimateZone 0,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2016,ClimateZone 0,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2016,ClimateZone 0,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2016,ClimateZone 0,Skylight,Glass with Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 0,Skylight,Glass with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 0,Skylight,Glass with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, +90.1-2016,ClimateZone 0,Skylight,Plastic with Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 0,Skylight,Plastic with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 0,Skylight,Plastic with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, +90.1-2016,ClimateZone 0,Skylight,Without Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 0,Skylight,Without Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, +90.1-2016,ClimateZone 0,Skylight,Without Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, +90.1-2019,ClimateZone 0,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 0,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 0,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 0,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table +90.1-2019,ClimateZone 0,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 0,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.032,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.115,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2019,ClimateZone 0,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2019,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1,Fixed +90.1-2019,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1,Fixed +90.1-2019,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.83 SHGC 0.2 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.2,1.1,Entrance door +90.1-2019,ClimateZone 0,ExteriorWindow,Fixed,Nonresidential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1, +90.1-2019,ClimateZone 0,ExteriorWindow,Operable,Nonresidential,U 0.62 SHGC 0.2 Simple Glazing Window,,,,0.62,TRUE,TRUE,,,0.2,1.1, +90.1-2019,ClimateZone 0,ExteriorWindow,Entrance door,Nonresidential,U 0.83 SHGC 0.2 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.2,1.1, +90.1-2019,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1,Fixed +90.1-2019,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1,Fixed +90.1-2019,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 0.83 SHGC 0.2 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.2,1.1,Entrance door +90.1-2019,ClimateZone 0,ExteriorWindow,Fixed,Residential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1, +90.1-2019,ClimateZone 0,ExteriorWindow,Operable,Residential,U 0.62 SHGC 0.2 Simple Glazing Window,,,,0.62,TRUE,TRUE,,,0.2,1.1, +90.1-2019,ClimateZone 0,ExteriorWindow,Entrance door,Residential,U 0.83 SHGC 0.2 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.2,1.1, +90.1-2019,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,,Fixed +90.1-2019,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.1 SHGC 0.45 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,,,Entrance door +90.1-2019,ClimateZone 0,ExteriorWindow,Fixed,Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorWindow,Operable,Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,ExteriorWindow,Entrance door,Semiheated,U 1.1 SHGC 0.45 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2019,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2019,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2019,ClimateZone 0,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 0,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2019,ClimateZone 0,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 0,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2019,ClimateZone 0,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2019,ClimateZone 0,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2019,ClimateZone 0,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2019,ClimateZone 0,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2019,ClimateZone 0,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2019,ClimateZone 0,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2019,ClimateZone 0,Skylight,Glass with Curb,Nonresidential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 0,Skylight,Glass with Curb,Residential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 0,Skylight,Glass with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,Skylight,Plastic with Curb,Nonresidential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 0,Skylight,Plastic with Curb,Residential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 0,Skylight,Plastic with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,,, +90.1-2019,ClimateZone 0,Skylight,Without Curb,Nonresidential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 0,Skylight,Without Curb,Residential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, +90.1-2019,ClimateZone 0,Skylight,Without Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 0,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,1.282,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.614,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,1.28,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2004,ClimateZone 0,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,1.18,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 0,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 0,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 0,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 0,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2004,ClimateZone 0,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2004,ClimateZone 0,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2004,ClimateZone 0,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 0,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 0,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2004,ClimateZone 0,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.36 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.36,, +90.1-2004,ClimateZone 0,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.19,, +90.1-2004,ClimateZone 0,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.16 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.16,, +90.1-2004,ClimateZone 0,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.34 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2004,ClimateZone 0,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.34,, +90.1-2004,ClimateZone 0,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.27,, +90.1-2004,ClimateZone 0,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.27,, +90.1-2004,ClimateZone 0,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 0,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.065,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.063,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.65,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,1.28,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2007,ClimateZone 0,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,1.18,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2007,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2007,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 0,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2007,ClimateZone 0,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 0,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2007,ClimateZone 0,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2007,ClimateZone 0,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2007,ClimateZone 0,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2007,ClimateZone 0,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 0,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 0,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2007,ClimateZone 0,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.49 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.49,, +90.1-2007,ClimateZone 0,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.49,, +90.1-2007,ClimateZone 0,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.39 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.39,, +90.1-2007,ClimateZone 0,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.34 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, +90.1-2007,ClimateZone 0,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.77,, +90.1-2007,ClimateZone 0,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.77,, +90.1-2007,ClimateZone 0,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.62,, +90.1-2007,ClimateZone 0,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 0,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.065,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.063,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.065,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.167,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2010,ClimateZone 0,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.093,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.093,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2010,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2010,ClimateZone 0,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 0,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2010,ClimateZone 0,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 0,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2010,ClimateZone 0,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, +90.1-2010,ClimateZone 0,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2010,ClimateZone 0,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2010,ClimateZone 0,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 0,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 0,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2010,ClimateZone 0,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.19,, +90.1-2010,ClimateZone 0,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.34 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.36,, +90.1-2010,ClimateZone 0,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, +90.1-2010,ClimateZone 0,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, +90.1-2010,ClimateZone 0,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, +90.1-2010,ClimateZone 0,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.39,, +90.1-2013,ClimateZone 0,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 0,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.1156,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, +90.1-2013,ClimateZone 0,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, +90.1-2013,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.93 SHGC 0.25 Simple Glazing Window,,,,0.93,TRUE,TRUE,,,0.25,, +90.1-2013,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2013,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,, +90.1-2013,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, +90.1-2013,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, +90.1-2013,ClimateZone 0,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 0,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2013,ClimateZone 0,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 0,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2013,ClimateZone 0,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, +90.1-2013,ClimateZone 0,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, +90.1-2013,ClimateZone 0,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, +90.1-2013,ClimateZone 0,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2013,ClimateZone 0,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2013,ClimateZone 0,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, +90.1-2013,ClimateZone 0,Skylight,Glass with Curb,Nonresidential,U 0.75 SHGC 0.45 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,Skylight,Glass with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.49,, +90.1-2013,ClimateZone 0,Skylight,Glass with Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,0.49,, +90.1-2013,ClimateZone 0,Skylight,Plastic with Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.39,, +90.1-2013,ClimateZone 0,Skylight,Plastic with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,Skylight,Plastic with Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,,, +90.1-2013,ClimateZone 0,Skylight,Without Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.68,, +90.1-2013,ClimateZone 0,Skylight,Without Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.64,, +90.1-2013,ClimateZone 0,Skylight,Without Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,0.64,, diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_boilers_90_1.csv b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_boilers_90_1.csv new file mode 100644 index 0000000000..608e4841f6 --- /dev/null +++ b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_boilers_90_1.csv @@ -0,0 +1,22 @@ +template,fluid_type,fuel_type,condensing,condensing_control,minimum_capacity,maximum_capacity,start_date,end_date,minimum_annual_fuel_utilization_efficiency,minimum_thermal_efficiency,minimum_combustion_efficiency,efffplr,annotation +90.1-2004,Hot Water,Gas,,,0,299999,9/9/1919,9/9/2999,0.8,,,Boiler with No Minimum Turndown,From 90.1-2004 +90.1-2004,Hot Water,Gas,,,300000,249999999,9/9/1919,9/9/2999,,0.75,,Boiler with No Minimum Turndown,From 90.1-2004 +90.1-2004,Hot Water,Gas,,,250000000,9999999999,9/9/1919,9/9/2999,,,0.8,Boiler with No Minimum Turndown,From 90.1-2004 +90.1-2007,Hot Water,Gas,,,0,299999,9/9/1919,9/9/2999,0.8,,,Boiler with No Minimum Turndown,From 90.1-2007 +90.1-2007,Hot Water,Gas,,,300000,249999999,9/9/1919,9/9/2999,,0.8,,Boiler with No Minimum Turndown,From 90.1-2007 +90.1-2007,Hot Water,Gas,,,250000000,9999999999,9/9/1919,9/9/2999,,,0.82,Boiler with No Minimum Turndown,From 90.1-2007 +90.1-2010,Hot Water,Gas,,,0,299999,9/9/1919,9/9/2999,0.8,,,Boiler with No Minimum Turndown,From 90.1-2010 +90.1-2010,Hot Water,Gas,,,300000,249999999,9/9/1919,9/9/2999,,0.8,,Boiler with No Minimum Turndown,From 90.1-2010 +90.1-2010,Hot Water,Gas,,,250000000,9999999999,9/9/1919,9/9/2999,,,0.82,Boiler with No Minimum Turndown,From 90.1-2010 +90.1-2013,Hot Water,Gas,,,0,299999,9/9/1919,9/9/2999,0.82,,,Boiler with No Minimum Turndown,From 90.1-2013 +90.1-2013,Hot Water,Gas,,,300000,999999,9/9/1919,9/9/2999,,0.8,,Boiler with No Minimum Turndown,From 90.1-2013 +90.1-2013,Hot Water,Gas,,,1000000,249999999,9/9/1919,9/9/2999,,0.8,,Boiler with Minimum Turndown,From 90.1-2013 +90.1-2013,Hot Water,Gas,,,250000000,9999999999,9/9/1919,9/9/2999,,,0.82,Boiler with Minimum Turndown,From 90.1-2013 +90.1-2016,Hot Water,Gas,,,0,299999,9/9/1919,9/9/2999,0.82,,,Boiler with No Minimum Turndown,From 90.1-2016 +90.1-2016,Hot Water,Gas,,,300000,999999,9/9/1919,9/9/2999,,0.8,,Boiler with No Minimum Turndown,From 90.1-2016 +90.1-2016,Hot Water,Gas,,,1000000,249999999,9/9/1919,9/9/2999,,0.8,,Boiler with Minimum Turndown,From 90.1-2016 +90.1-2016,Hot Water,Gas,,,250000000,9999999999,9/9/1919,9/9/2999,,,0.82,Boiler with Minimum Turndown,From 90.1-2016 +90.1-2019,Hot Water,Gas,,,0,299999,9/9/1919,9/9/2999,0.84,,,Boiler with No Minimum Turndown,From 90.1-2019 +90.1-2019,Hot Water,Gas,,,300000,999999,9/9/1919,9/9/2999,,0.8,,Boiler with No Minimum Turndown,From 90.1-2019 +90.1-2019,Hot Water,Gas,,,1000000,249999999,9/9/1919,9/9/2999,,0.8,,Boiler with Minimum Turndown,From 90.1-2019 +90.1-2019,Hot Water,Gas,,,250000000,9999999999,9/9/1919,9/9/2999,,,0.82,Boiler with Minimum Turndown,From 90.1-2019 diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_chillers_90_1.csv b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_chillers_90_1.csv new file mode 100644 index 0000000000..c904371f30 --- /dev/null +++ b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_chillers_90_1.csv @@ -0,0 +1,163 @@ +template,cooling_type,condenser_type,compressor_type,absorption_type,variable_speed_drive,minimum_capacity,maximum_capacity,start_date,end_date,minimum_full_load_efficiency,minimum_integrated_part_load_value,capft,eirft,eirfplr,annotation +90.1-2004,AirCooled,WithCondenser,,,,0,9999,9/9/1919,9/9/2999,1.256,1.153,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR, +90.1-2004,AirCooled,WithoutCondenser,,,,0,9999,9/9/1919,9/9/2999,1.135,1.019,ChlrAirRecipQRatio_fTchwsToadbSI,ChlrAirRecipEIRRatio_fTchwsToadbSI,ChlrAirRecipEIRRatio_fQRatio, +90.1-2004,AirCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.862,,,,, +90.1-2007,AirCooled,WithCondenser,,,,0,9999,9/9/1919,9/9/2999,1.29,1.164,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Form 90.1-2007 Table 6.8.1A +90.1-2010,AirCooled,WithCondenser,,,,0,149.99,9/9/1919,9/9/2999,1.255,0.941,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR, +90.1-2010,AirCooled,WithCondenser,,,,150,9999,9/9/1919,9/9/2999,1.255,0.941,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR, +90.1-2010,AirCooled,WithoutCondenser,,,,0,9999,9/9/1919,9/9/2999,1.255,0.941,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR, +90.1-2010,AirCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.862,,,,, +90.1-2013,AirCooled,WithCondenser,,,,0,149.99,9/9/1919,12/31/2014,1.25,0.96,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies +90.1-2013,AirCooled,WithCondenser,,,,150,9999,9/9/1919,12/31/2014,1.25,0.94,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies +90.1-2013,AirCooled,WithoutCondenser,,,,0,149.99,9/9/1919,12/31/2014,1.25,0.96,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,AirCooled,WithoutCondenser,,,,150,9999,9/9/1919,12/31/2014,1.25,0.94,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,AirCooled,,,Single Effect,,0,9999,9/9/1919,12/31/2014,5.862,,,,,Path A Efficiencies +90.1-2013,AirCooled,WithCondenser,,,,0,149.99,1/1/2015,12/31/2014,1.188,0.876,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies +90.1-2013,AirCooled,WithCondenser,,,,150,9999,1/1/2015,9/9/2999,1.188,0.857,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies +90.1-2013,AirCooled,WithoutCondenser,,,,0,149.99,1/1/2015,9/9/2999,1.188,0.876,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,AirCooled,WithoutCondenser,,,,150,9999,1/1/2015,9/9/2999,1.188,0.857,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,AirCooled,,,Single Effect,,0,9999,1/1/2015,9/9/2999,5.862,,,,,Path A Efficiencies +90.1-2004,WaterCooled,,Reciprocating,,,0,149.99,9/9/1919,9/9/2999,0.837,0.696,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, +90.1-2004,WaterCooled,,Reciprocating,,,150,9999,9/9/1919,9/9/2999,0.837,0.696,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, +90.1-2004,WaterCooled,,Rotary Screw,,,0,149.99,9/9/1919,9/9/2999,0.79,0.676,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, +90.1-2004,WaterCooled,,Rotary Screw,,,150,299.99,9/9/1919,9/9/2999,0.718,0.628,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, +90.1-2004,WaterCooled,,Rotary Screw,,,300,9999,9/9/1919,9/9/2999,0.639,0.572,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, +90.1-2004,WaterCooled,,Scroll,,,0,149.99,9/9/1919,9/9/2999,0.79,0.676,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, +90.1-2004,WaterCooled,,Scroll,,,150,299.99,9/9/1919,9/9/2999,0.718,0.628,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, +90.1-2004,WaterCooled,,Scroll,,,300,9999,9/9/1919,9/9/2999,0.639,0.572,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, +90.1-2004,WaterCooled,,Centrifugal,,,150,299.99,9/9/1919,9/9/2999,0.634,0.596,WaterCooled_Centrifugal_Chiller_LT150_2004_CAPFT,WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio, +90.1-2004,WaterCooled,,Centrifugal,,,0,149.99,9/9/1919,9/9/2999,0.703,0.67,WaterCooled_Centrifugal_Chiller_LT150_2004_CAPFT,WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio, +90.1-2004,WaterCooled,,Centrifugal,,,300,9999,9/9/1919,9/9/2999,0.577,0.55,WaterCooled_Centrifugal_Chiller_GT150_2004_CAPFT,WaterCooled_Centrifugal_Chiller_GT150_2004_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio, +90.1-2004,WaterCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.024,,,,, +90.1-2007,WaterCooled,,Reciprocating,,,0,74.99,9/9/1919,9/9/2999,0.78,0.63,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Reciprocating,,,75,149.99,9/9/1919,9/9/2999,0.775,0.615,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Reciprocating,,,150,299.99,9/9/1919,9/9/2999,0.68,0.58,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Reciprocating,,,300,9999,9/9/1919,9/9/2999,0.62,0.54,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Scroll,,,0,74.99,9/9/1919,9/9/2999,0.78,0.63,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Scroll,,,75,149.99,9/9/1919,9/9/2999,0.775,0.615,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Scroll,,,150,299.99,9/9/1919,9/9/2999,0.68,0.58,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Scroll,,,300,9999,9/9/1919,9/9/2999,0.62,0.54,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Rotary Screw,,,0,74.99,9/9/1919,9/9/2999,0.78,0.63,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Rotary Screw,,,75,149.99,9/9/1919,9/9/2999,0.775,0.615,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Rotary Screw,,,150,299.99,9/9/1919,9/9/2999,0.68,0.58,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Rotary Screw,,,300,9999,9/9/1919,9/9/2999,0.62,0.54,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Centrifugal,,,0,149.99,9/9/1919,9/9/2999,0.634,0.596,WaterCooled_Centrifugal_Chiller_LT150_2004_CAPFT,WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Centrifugal,,,150,299.99,9/9/1919,9/9/2999,0.634,0.596,WaterCooled_Centrifugal_Chiller_LT150_2004_CAPFT,WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Centrifugal,,,300,599.99,9/9/1919,9/9/2999,0.576,0.549,WaterCooled_Centrifugal_Chiller_GT150_2004_CAPFT,WaterCooled_Centrifugal_Chiller_GT150_2004_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2007,WaterCooled,,Centrifugal,,,600,9999,9/9/1919,9/9/2999,0.57,0.539,WaterCooled_Centrifugal_Chiller_GT150_2004_CAPFT,WaterCooled_Centrifugal_Chiller_GT150_2004_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Reciprocating,,,0,74.99,9/9/1919,9/9/2999,0.78,0.63,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Reciprocating,,,75,149.99,9/9/1919,9/9/2999,0.775,0.615,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Reciprocating,,,150,299.99,9/9/1919,9/9/2999,0.68,0.58,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Reciprocating,,,300,9999,9/9/1919,9/9/2999,0.62,0.54,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Scroll,,,0,74.99,9/9/1919,9/9/2999,0.78,0.63,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Scroll,,,75,149.99,9/9/1919,9/9/2999,0.775,0.615,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Scroll,,,150,299.99,9/9/1919,9/9/2999,0.68,0.58,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Scroll,,,300,9999,9/9/1919,9/9/2999,0.62,0.54,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Rotary Screw,,,0,74.99,9/9/1919,9/9/2999,0.78,0.63,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Rotary Screw,,,75,149.99,9/9/1919,9/9/2999,0.775,0.615,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Rotary Screw,,,150,299.99,9/9/1919,9/9/2999,0.68,0.58,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Rotary Screw,,,300,9999,9/9/1919,9/9/2999,0.62,0.54,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Centrifugal,,,0,149.99,9/9/1919,9/9/2999,0.634,0.596,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Centrifugal,,,150,299.99,9/9/1919,9/9/2999,0.634,0.596,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Centrifugal,,,300,599.99,9/9/1919,9/9/2999,0.576,0.549,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,Centrifugal,,,600,9999,9/9/1919,9/9/2999,0.57,0.539,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies +90.1-2010,WaterCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.024,,,,, +90.1-2013,WaterCooled,,Reciprocating,,,0,74.99,9/9/1919,12/31/2014,0.78,0.63,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Reciprocating,,,75,149.99,9/9/1919,12/31/2014,0.775,0.615,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Reciprocating,,,150,299.99,9/9/1919,12/31/2014,0.68,0.58,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Reciprocating,,,300,599.99,9/9/1919,12/31/2014,0.62,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Reciprocating,,,600,9999,9/9/1919,12/31/2014,0.62,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Scroll,,,0,74.99,9/9/1919,12/31/2014,0.78,0.63,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Scroll,,,75,149.99,9/9/1919,12/31/2014,0.775,0.615,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Scroll,,,150,299.99,9/9/1919,12/31/2014,0.68,0.58,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Scroll,,,300,599.99,9/9/1919,12/31/2014,0.62,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Scroll,,,600,9999,9/9/1919,12/31/2014,0.62,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Rotary Screw,,,0,74.99,9/9/1919,12/31/2014,0.78,0.63,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Rotary Screw,,,75,149.99,9/9/1919,12/31/2014,0.775,0.615,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Rotary Screw,,,150,299.99,9/9/1919,12/31/2014,0.68,0.58,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Rotary Screw,,,300,599.99,9/9/1919,12/31/2014,0.62,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Rotary Screw,,,600,9999,9/9/1919,12/31/2014,0.62,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Centrifugal,,,0,149.99,9/9/1919,12/31/2014,0.634,0.596,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Centrifugal,,,150,399.99,9/9/1919,12/31/2014,0.634,0.596,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Centrifugal,,,400,599.99,9/9/1919,12/31/2014,0.576,0.549,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Centrifugal,,,600,9999,9/9/1919,12/31/2014,0.57,0.539,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Add but unsure what to put for Minimum full load efficiency and min IPLV +90.1-2013,WaterCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.024,,,,,Path A Efficiencies +90.1-2013,WaterCooled,,Reciprocating,,,0,74.99,1/1/2015,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Reciprocating,,,75,149.99,1/1/2015,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Reciprocating,,,150,299.99,1/1/2015,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Reciprocating,,,300,599.99,1/1/2015,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Reciprocating,,,600,9999,1/1/2015,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Scroll,,,0,74.99,1/1/2015,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Scroll,,,75,149.99,1/1/2015,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Scroll,,,150,299.99,1/1/2015,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Scroll,,,300,599.99,1/1/2015,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Scroll,,,600,9999,1/1/2015,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Rotary Screw,,,0,74.99,1/1/2015,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Rotary Screw,,,75,149.99,1/1/2015,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Rotary Screw,,,150,299.99,1/1/2015,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Rotary Screw,,,300,599.99,1/1/2015,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Rotary Screw,,,600,9999,1/1/2015,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Centrifugal,,,0,149.99,1/1/2015,9/9/2999,0.61,0.55,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Centrifugal,,,150,399.99,1/1/2015,9/9/2999,0.56,0.52,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Centrifugal,,,400,599.99,1/1/2015,9/9/2999,0.56,0.5,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2013,WaterCooled,,Centrifugal,,,600,9999,1/1/2015,9/9/2999,0.56,0.5,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Add but unsure what to put for Minimum full load efficiency and min IPLV +90.1-2004,,,,Double Effect Indirect Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.35,,,, +90.1-2004,,,,Double Effect Direct Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.517,,,, +90.1-2010,,,,Double Effect Indirect Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.35,,,, +90.1-2010,,,,Double Effect Direct Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.517,,,, +90.1-2013,,,,Double Effect Indirect Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.35,,,,Path A Efficiencies +90.1-2013,,,,Double Effect Direct Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.517,,,,Path A Efficiencies +90.1-2016,AirCooled,WithCondenser,,,,0,149.99,9/9/1919,9/9/2999,1.188,0.876,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies +90.1-2016,AirCooled,WithCondenser,,,,150,9999,9/9/1919,9/9/2999,1.188,0.857,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies +90.1-2016,AirCooled,WithoutCondenser,,,,0,149.99,9/9/1919,9/9/2999,1.188,0.876,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,AirCooled,WithoutCondenser,,,,150,9999,9/9/1919,9/9/2999,1.188,0.857,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,AirCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.862,,,,,Path A Efficiencies +90.1-2016,WaterCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.024,,,,,Path A Efficiencies +90.1-2016,WaterCooled,,Reciprocating,,,0,74.99,9/9/1919,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Reciprocating,,,75,149.99,9/9/1919,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Reciprocating,,,150,299.99,9/9/1919,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Reciprocating,,,300,599.99,9/9/1919,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Reciprocating,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Scroll,,,0,74.99,9/9/1919,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Scroll,,,75,149.99,9/9/1919,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Scroll,,,150,299.99,9/9/1919,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Scroll,,,300,599.99,9/9/1919,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Scroll,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Rotary Screw,,,0,74.99,9/9/1919,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Rotary Screw,,,75,149.99,9/9/1919,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Rotary Screw,,,150,299.99,9/9/1919,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Rotary Screw,,,300,599.99,9/9/1919,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Rotary Screw,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Centrifugal,,,0,149.99,9/9/1919,9/9/2999,0.61,0.55,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Centrifugal,,,150,399.99,9/9/1919,9/9/2999,0.56,0.52,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Centrifugal,,,400,599.99,9/9/1919,9/9/2999,0.56,0.5,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,WaterCooled,,Centrifugal,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2016,,,,Double Effect Indirect Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.35,,,,Path A Efficiencies +90.1-2016,,,,Double Effect Direct Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.517,,,,Path A Efficiencies +90.1-2019,AirCooled,WithCondenser,,,,0,149.99,9/9/1919,9/9/2999,1.188,0.876,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies +90.1-2019,AirCooled,WithCondenser,,,,150,9999,9/9/1919,9/9/2999,1.188,0.857,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies +90.1-2019,AirCooled,WithoutCondenser,,,,0,149.99,9/9/1919,9/9/2999,1.188,0.876,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,AirCooled,WithoutCondenser,,,,150,9999,9/9/1919,9/9/2999,1.188,0.857,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,AirCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.862,,,,,Path A Efficiencies +90.1-2019,WaterCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.024,,,,,Path A Efficiencies +90.1-2019,WaterCooled,,Reciprocating,,,0,74.99,9/9/1919,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Reciprocating,,,75,149.99,9/9/1919,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Reciprocating,,,150,299.99,9/9/1919,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Reciprocating,,,300,599.99,9/9/1919,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Reciprocating,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Scroll,,,0,74.99,9/9/1919,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Scroll,,,75,149.99,9/9/1919,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Scroll,,,150,299.99,9/9/1919,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Scroll,,,300,599.99,9/9/1919,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Scroll,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Rotary Screw,,,0,74.99,9/9/1919,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Rotary Screw,,,75,149.99,9/9/1919,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Rotary Screw,,,150,299.99,9/9/1919,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Rotary Screw,,,300,599.99,9/9/1919,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Rotary Screw,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Centrifugal,,,0,149.99,9/9/1919,9/9/2999,0.61,0.55,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Centrifugal,,,150,399.99,9/9/1919,9/9/2999,0.56,0.52,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Centrifugal,,,400,599.99,9/9/1919,9/9/2999,0.56,0.5,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,WaterCooled,,Centrifugal,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies +90.1-2019,,,,Double Effect Indirect Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.35,,,,Path A Efficiencies +90.1-2019,,,,Double Effect Direct Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.517,,,,Path A Efficiencies diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_furnaces_90_1.csv b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_furnaces_90_1.csv new file mode 100644 index 0000000000..7bbcdb7238 --- /dev/null +++ b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_furnaces_90_1.csv @@ -0,0 +1,13 @@ +template,minimum_capacity,maximum_capacity,start_date,end_date,minimum_annual_fuel_utilization_efficiency,minimum_thermal_efficiency,minimum_combustion_efficiency,annotation +90.1-2004,0,224999,9/9/1919,9/9/2999,0.78,0.8,,Table 6.8.1E page 49 +90.1-2004,225000,249999999,9/9/1919,9/9/2999,,,0.8,Table 6.8.1E page 49 +90.1-2007,0,224999,9/9/1919,9/9/2999,0.78,0.8,,Table 6.8.1E page 49 +90.1-2007,225000,249999999,9/9/1919,9/9/2999,,,0.8,Table 6.8.1E page 49 +90.1-2010,0,224999,9/9/1919,9/9/2999,0.78,0.8,,Table 6.8.1E page 62 +90.1-2010,225000,249999999,9/9/1919,9/9/2999,,0.8,,Table 6.8.1E page 62 +90.1-2013,0,224999,9/9/1919,9/9/2999,0.78,0.8,,Table 6.8.1E page 72 +90.1-2013,225000,249999999,9/9/1919,9/9/2999,,0.8,,Table 6.8.1E page 72 +90.1-2016,0,224999,9/9/1919,9/9/2999,0.78,0.8,,Table 6.8.1E page 116 +90.1-2016,225000,249999999,9/9/1919,9/9/2999,,0.8,,Table 6.8.1E page 116 +90.1-2019,0,224999,9/9/1919,9/9/2999,,0.81,,Table 6.8.1-6 for > 225 ktbu/hr; Table F-4 for < 225 ktbu/hr +90.1-2019,225000,249999999,9/9/1919,9/9/2999,,0.8,,Table 6.8.1-6 for > 225 ktbu/hr; Table F-4 for < 225 ktbu/hr diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_pump_cooling_90_1.csv b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_pump_cooling_90_1.csv new file mode 100644 index 0000000000..3ea90977be --- /dev/null +++ b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_pump_cooling_90_1.csv @@ -0,0 +1,165 @@ +template,cooling_type,heating_type,subcategory,minimum_capacity,maximum_capacity,start_date,end_date,minimum_seasonal_efficiency,minimum_full_load_efficiency,minimum_iplv,minimum_integrated_energy_efficiency_ratio,pthp_eer_coefficient_1,pthp_eer_coefficient_2,cool_cap_ft,cool_cap_fflow,cool_eir_ft,cool_eir_fflow,cool_plf_fplr,annotation +90.1-2004,AirCooled,Electric Resistance or None,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,12.3,0.213,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1D +90.1-2004,AirCooled,All Other,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,12.3,0.213,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1D +90.1-2007,AirCooled,Electric Resistance or None,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,12.3,0.213,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2007 Table 6.8.1D +90.1-2007,AirCooled,All Other,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,12.3,0.213,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2007 Table 6.8.1D +90.1-2010,AirCooled,Electric Resistance or None,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,12.3,0.213,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1D Before 10/8/2012 +90.1-2010,AirCooled,All Other,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,12.3,0.213,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1D Before 10/8/2012 +90.1-2013,AirCooled,Electric Resistance or None,PTHP,0,9999999,9/9/1919,12/31/2015,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2013 Table 6.8.1-4 +90.1-2013,AirCooled,All Other,PTHP,0,9999999,9/9/1919,12/31/2015,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2013 Table 6.8.1-4 +90.1-2013,AirCooled,Electric Resistance or None,PTHP,0,9999999,1/1/2016,9/9/2999,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2013 Table 6.8.1-4 +90.1-2013,AirCooled,All Other,PTHP,0,9999999,1/1/2016,9/9/2999,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2013 Table 6.8.1-4 +90.1-2004,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,9.7,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2004,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,9.7,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2004,ThroughWall,Electric Resistance or None,Single Package,0,29999,9/9/1919,9/9/2999,9.7,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2004,ThroughWall,All Other,Single Package,0,29999,9/9/1919,9/9/2999,9.7,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2004,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B +90.1-2004,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,9.9,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B +90.1-2004,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,9.3,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B +90.1-2004,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,9.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B +90.1-2004,AirCooled,Electric Resistance or None,Single Package,240000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B +90.1-2004,AirCooled,All Other,Single Package,240000,9999999,9/9/1919,9/9/2999,,8.8,9,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B +90.1-2007,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" +90.1-2007,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" +90.1-2007,ThroughWall,Electric Resistance or None,Single Package,0,29999,9/9/1919,9/9/2999,10.6,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" +90.1-2007,ThroughWall,All Other,Single Package,0,29999,9/9/1919,9/9/2999,10.6,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" +90.1-2007,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" +90.1-2007,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,9.9,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" +90.1-2007,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,9.3,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" +90.1-2007,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,9.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" +90.1-2007,AirCooled,Electric Resistance or None,Single Package,240000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" +90.1-2007,AirCooled,All Other,Single Package,240000,9999999,9/9/1919,9/9/2999,,8.8,9,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" +90.1-2010,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,ThroughWall,Electric Resistance or None,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,ThroughWall,All Other,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,11,,11.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,10.8,,11,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,10.6,,10.7,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,10.4,,10.5,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,Electric Resistance or None,Single Package,240000,9999999,9/9/1919,9/9/2999,,9.5,,9.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,All Other,Single Package,240000,9999999,9/9/1919,9/9/2999,,9.3,,9.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2013,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,12/31/2014,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 +90.1-2013,AirCooled,All Other,Single Package,0,64999,9/9/1919,12/31/2014,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 +90.1-2013,AirCooled,Electric Resistance or None,Single Package,0,64999,1/1/2015,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 +90.1-2013,AirCooled,All Other,Single Package,0,64999,1/1/2015,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 +90.1-2013,ThroughWall,Electric Resistance or None,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 +90.1-2013,ThroughWall,All Other,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 +90.1-2013,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,12/31/2015,,11,,11.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,Electric Resistance or None,Single Package,65000,134999,1/1/2016,9/9/2999,,11,,12.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,All Other,Single Package,65000,134999,9/9/1919,12/31/2015,,10.8,,11,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,All Other,Single Package,65000,134999,1/1/2016,9/9/2999,,10.8,,12,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,12/31/2015,,10.6,,10.7,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,Electric Resistance or None,Single Package,135000,239999,1/1/2016,9/9/2999,,10.6,,11.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,All Other,Single Package,135000,239999,9/9/1919,12/31/2015,,10.4,,10.5,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,All Other,Single Package,135000,239999,1/1/2016,9/9/2999,,10.4,,11.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,Electric Resistance or None,Single Package,240000,9999999,9/9/1919,12/31/2015,,9.5,,9.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,Electric Resistance or None,Single Package,240000,9999999,1/1/2016,9/9/2999,,9.5,,10.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,All Other,Single Package,240000,9999999,9/9/1919,12/31/2015,,9.3,,9.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,All Other,Single Package,240000,9999999,1/1/2016,9/9/2999,,9.3,,0.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2004,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,10,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2004,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,10,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2004,ThroughWall,Electric Resistance or None,Split System,0,29999,9/9/1919,9/9/2999,10,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2004,ThroughWall,All Other,Split System,0,29999,9/9/1919,9/9/2999,10,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2004,SmallDuctHighVelocity,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,10,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B +90.1-2004,SmallDuctHighVelocity,All Other,Split System,0,64999,9/9/1919,9/9/2999,10,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B +90.1-2004,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B +90.1-2004,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,9.9,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B +90.1-2004,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,9.3,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B +90.1-2004,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,9.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B +90.1-2004,AirCooled,Electric Resistance or None,Split System,240000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B +90.1-2004,AirCooled,All Other,Split System,240000,9999999,9/9/1919,9/9/2999,,8.8,9,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B +90.1-2007,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" +90.1-2007,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" +90.1-2007,ThroughWall,Electric Resistance or None,Split System,0,29999,9/9/1919,9/9/2999,10.9,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" +90.1-2007,ThroughWall,All Other,Split System,0,29999,9/9/1919,9/9/2999,10.9,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" +90.1-2007,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" +90.1-2007,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,9.9,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" +90.1-2007,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,9.3,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" +90.1-2007,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,9.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" +90.1-2007,AirCooled,Electric Resistance or None,Split System,240000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" +90.1-2007,AirCooled,All Other,Split System,240000,9999999,9/9/1919,9/9/2999,,8.8,9,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" +90.1-2010,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,ThroughWall,Electric Resistance or None,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,ThroughWall,All Other,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,11,,11.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,10.8,,11,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,10.6,,10.7,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,10.4,,10.5,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,Electric Resistance or None,Split System,240000,9999999,9/9/1919,9/9/2999,,9.5,,9.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,All Other,Split System,240000,9999999,9/9/1919,9/9/2999,,9.3,,9.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2013,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,12/31/2014,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 +90.1-2013,AirCooled,All Other,Split System,0,64999,9/9/1919,12/31/2014,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 +90.1-2013,AirCooled,Electric Resistance or None,Split System,0,64999,1/1/2015,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 +90.1-2013,AirCooled,All Other,Split System,0,64999,1/1/2015,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 +90.1-2013,ThroughWall,Electric Resistance or None,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 +90.1-2013,ThroughWall,All Other,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 +90.1-2013,SmallDuctHighVelocity,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,11,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,SmallDuctHighVelocity,All Other,Split System,0,64999,9/9/1919,9/9/2999,11,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,12/31/2015,,11,,11.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,Electric Resistance or None,Split System,65000,134999,1/1/2016,9/9/2999,,11,,12.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,All Other,Split System,65000,134999,9/9/1919,12/31/2015,,10.8,,11,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,All Other,Split System,65000,134999,1/1/2016,9/9/2999,,10.8,,12,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,12/31/2015,,10.6,,10.7,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,Electric Resistance or None,Split System,135000,239999,1/1/2016,9/9/2999,,10.6,,11.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,All Other,Split System,135000,239999,9/9/1919,12/31/2015,,10.4,,10.5,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,All Other,Split System,135000,239999,1/1/2016,9/9/2999,,10.4,,11.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,Electric Resistance or None,Split System,240000,9999999,9/9/1919,12/31/2015,,9.5,,9.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,Electric Resistance or None,Split System,240000,9999999,1/1/2016,9/9/2999,,9.5,,10.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,All Other,Split System,240000,9999999,9/9/1919,12/31/2015,,9.3,,9.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2013,AirCooled,All Other,Split System,240000,9999999,1/1/2016,9/9/2999,,9.3,,0.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 +90.1-2016,AirCooled,Electric Resistance or None,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,All Other,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,ThroughWall,Electric Resistance or None,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,ThroughWall,All Other,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,11,,12.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,10.8,,12,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,10.6,,11.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,10.4,,11.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,Electric Resistance or None,Single Package,240000,9999999,9/9/1919,9/9/2999,,9.5,,10.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,All Other,Single Package,240000,9999999,9/9/1919,9/9/2999,,9.3,,0.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,ThroughWall,Electric Resistance or None,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,ThroughWall,All Other,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,SmallDuctHighVelocity,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,11,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,SmallDuctHighVelocity,All Other,Split System,0,64999,9/9/1919,9/9/2999,11,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,11,,12.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,10.8,,12,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,10.6,,11.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,10.4,,11.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,Electric Resistance or None,Split System,240000,9999999,9/9/1919,9/9/2999,,9.5,,10.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,All Other,Split System,240000,9999999,9/9/1919,9/9/2999,,9.3,,0.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,PTHP,0,6999,9/9/1919,9/9/2999,,11.9,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,PTHP,0,6999,9/9/1919,9/9/2999,,11.9,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,PTHP,7000,14999,1/1/2016,9/9/2999,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,PTHP,7000,14999,1/1/2016,9/9/2999,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,PTHP,15000,9999999,9/9/1919,9/9/2999,,9.5,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,PTHP,15000,9999999,9/9/1919,9/9/2999,,9.5,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,12/31/2014,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,Single Package,0,64999,9/9/1919,12/31/2014,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,ThroughWall,Electric Resistance or None,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,ThroughWall,All Other,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,11,,12.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,10.8,,12,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,10.6,,11.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,10.4,,11.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,Single Package,240000,9999999,9/9/1919,9/9/2999,,9.5,,10.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,Single Package,240000,9999999,9/9/1919,9/9/2999,,9.3,,0.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,ThroughWall,Electric Resistance or None,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,ThroughWall,All Other,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,SmallDuctHighVelocity,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,11,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,SmallDuctHighVelocity,All Other,Split System,0,64999,9/9/1919,9/9/2999,11,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,11,,12.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,10.8,,12,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,10.6,,11.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,10.4,,11.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,Split System,240000,9999999,9/9/1919,9/9/2999,,9.5,,10.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,Split System,240000,9999999,9/9/1919,9/9/2999,,9.3,,0.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_pump_heating_90_1.csv b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_pump_heating_90_1.csv new file mode 100644 index 0000000000..b5fe02a2c7 --- /dev/null +++ b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_pump_heating_90_1.csv @@ -0,0 +1,51 @@ +template,cooling_type,subcategory,minimum_capacity,maximum_capacity,start_date,end_date,minimum_heating_seasonal_performance_factor,minimum_coefficient_of_performance_heating,minimum_energy_efficiency_ratio,pthp_cop_coefficient_1,pthp_cop_coefficient_2,heat_cap_ft,heat_cap_fflow,heat_eir_ft,heat_eir_fflow,heat_plf_fplr,annotation +90.1-2004,AirCooled,PTHP,0,9999999,9/9/1919,9/9/2999,,,,3.2,0.026,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2004 Table 6.8.1D +90.1-2007,AirCooled,PTHP,0,9999999,9/9/1919,9/9/2999,,,,3.2,0.026,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2007 Table 6.8.1D +90.1-2010,AirCooled,PTHP,0,9999999,9/9/1919,9/9/2999,,,,3.2,0.026,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2010 Table 6.8.1D before 10/08/2012 +90.1-2013,AirCooled,PTHP,0,9999999,9/9/1919,9/9/2999,,,,3.7,0.052,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2013 Table 6.8.1-4 +90.1-2004,AirCooled,Single Package,0,64999,9/9/1919,9/9/2999,6.6,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2004,ThroughWall,Single Package,0,29999,9/9/1919,9/9/2999,6.6,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2004,AirCooled,Single Package,65000,134999,9/9/1919,9/9/2999,,3.2,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2004,AirCooled,Single Package,135000,9999999,9/9/1919,9/9/2999,,3.1,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2007,AirCooled,Single Package,0,64999,9/9/1919,9/9/2999,7.7,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" +90.1-2007,ThroughWall,Single Package,0,29999,9/9/1919,9/9/2999,7,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" +90.1-2007,AirCooled,Single Package,65000,134999,9/9/1919,9/9/2999,,3.2,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" +90.1-2007,AirCooled,Single Package,135000,9999999,9/9/1919,9/9/2999,,3.1,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" +90.1-2010,AirCooled,Single Package,0,64999,9/9/1919,9/9/2999,7.7,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,ThroughWall,Single Package,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,Single Package,65000,134999,9/9/1919,9/9/2999,,3.3,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,AirCooled,Single Package,135000,9999999,9/9/1919,9/9/2999,,3.2,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2013,AirCooled,Single Package,0,64999,9/9/1919,12/31/2014,7.7,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2013 Table 6.8.1-2, Before 1/1/2015" +90.1-2013,AirCooled,Single Package,0,64999,1/1/2015,9/9/2999,8,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2013 Table 6.8.1-2, Before 1/1/2015" +90.1-2013,ThroughWall,Single Package,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2013 Table 6.8.1-3 +90.1-2013,AirCooled,Single Package,65000,134999,9/9/1919,9/9/2999,,3.3,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR,From 90.1-2013 Table 6.8.1-5 +90.1-2013,AirCooled,Single Package,135000,9999999,9/9/1919,9/9/2999,,3.2,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR,From 90.1-2013 Table 6.8.1-6 +90.1-2004,AirCooled,Split System,0,64999,9/9/1919,9/9/2999,6.8,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2004,ThroughWall,Split System,0,29999,9/9/1919,9/9/2999,6.8,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2004,SmallDuctHighVelocity,Split System,0,64999,9/9/1919,9/9/2999,6.8,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" +90.1-2007,AirCooled,Split System,0,64999,9/9/1919,9/9/2999,7.7,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" +90.1-2007,ThroughWall,Split System,0,29999,9/9/1919,9/9/2999,7.1,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" +90.1-2010,AirCooled,Split System,0,64999,9/9/1919,9/9/2999,7.7,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2010,ThroughWall,Split System,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2010 Table 6.8.1B +90.1-2013,AirCooled,Split System,0,64999,9/9/1919,12/31/2014,7.7,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2013 Table 6.8.1-2, Before 1/1/2015" +90.1-2013,AirCooled,Split System,0,64999,1/1/2015,9/9/2999,8.2,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2013 Table 6.8.1-2, Before 1/1/2015" +90.1-2013,ThroughWall,Split System,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2013 Table 6.8.1-2 +90.1-2013,SmallDuctHighVelocity,Split System,0,64999,9/9/1919,9/9/2999,6.8,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2013 Table 6.8.1-4 +90.1-2016,AirCooled,PTHP,0,9999999,9/9/1919,9/9/2999,,,,3.7,0.052,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, +90.1-2016,AirCooled,Single Package,0,64999,9/9/1919,9/9/2999,8,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,ThroughWall,Single Package,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, +90.1-2016,AirCooled,Single Package,65000,134999,9/9/1919,9/9/2999,,3.3,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,Single Package,135000,9999999,9/9/1919,9/9/2999,,3.2,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,Split System,0,64999,9/9/1919,9/9/2999,8.2,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, +90.1-2016,ThroughWall,Split System,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, +90.1-2016,SmallDuctHighVelocity,Split System,0,64999,9/9/1919,9/9/2999,6.8,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, +90.1-2019,AirCooled,PTHP,0,6999,9/9/1919,9/9/2999,,3.3,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, +90.1-2019,AirCooled,PTHP,6999,14999,9/9/1919,9/9/2999,,,,3.7,0.052,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, +90.1-2019,AirCooled,PTHP,14999,9999999,9/9/1919,9/9/2999,,2.9,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, +90.1-2019,AirCooled,Single Package,0,64999,9/9/1919,9/9/2999,8,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,ThroughWall,Single Package,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, +90.1-2019,AirCooled,Single Package,65000,134999,9/9/1919,9/9/2999,,3.3,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Single Package,135000,9999999,9/9/1919,9/9/2999,,3.2,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Split System,0,64999,9/9/1919,9/9/2999,8.2,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, +90.1-2019,ThroughWall,Split System,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, +90.1-2019,SmallDuctHighVelocity,Split System,0,64999,9/9/1919,9/9/2999,6.8,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_rejection_90_1.csv b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_rejection_90_1.csv new file mode 100644 index 0000000000..886007d819 --- /dev/null +++ b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_rejection_90_1.csv @@ -0,0 +1,31 @@ +template,equipment_type,fan_type,start_date,end_date,minimum_performance_gpm_per_hp,annotation +90.1-2004,Open Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2004 Table 6.8.1G +90.1-2004,Open Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,38.2,From 90.1-2004 Table 6.8.1G +90.1-2004,Closed Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2004 Table 6.8.1G +90.1-2004,Closed Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,38.2,From 90.1-2004 Table 6.8.1G +90.1-2004,Dry Cooler,Propeller or Axial,9/9/1919,9/9/2999,4,Not required by code. Value provided by 90.1 Mechanical Subcommittee +90.1-2007,Open Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2007 Table 6.8.1G +90.1-2007,Open Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,38.2,From 90.1-2007 Table 6.8.1G +90.1-2007,Closed Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2007 Table 6.8.1G +90.1-2007,Closed Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,38.2,From 90.1-2007 Table 6.8.1G +90.1-2007,Dry Cooler,Propeller or Axial,9/9/1919,9/9/2999,4,Not required by code. Value provided by 90.1 Mechanical Subcommittee +90.1-2010,Open Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2010 Table 6.8.1 G +90.1-2010,Open Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,38.2,From 90.1-2010 Table 6.8.1 G +90.1-2010,Closed Cooling Tower,Centrifugal,9/9/1919,9/9/2999,7,From 90.1-2010 Table 6.8.1 G +90.1-2010,Closed Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,14,From 90.1-2010 Table 6.8.1 G +90.1-2010,Dry Cooler,Propeller or Axial,9/9/1919,9/9/2999,4,Not required by code. Value provided by 90.1 Mechanical Subcommittee +90.1-2013,Open Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2013 Table 6.8.1-7 +90.1-2013,Open Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,40.2,From 90.1-2013 Table 6.8.1-7 +90.1-2013,Closed Cooling Tower,Centrifugal,9/9/1919,9/9/2999,7,From 90.1-2013 Table 6.8.1-7 +90.1-2013,Closed Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,14,From 90.1-2013 Table 6.8.1-7 +90.1-2013,Dry Cooler,Propeller or Axial,9/9/1919,9/9/2999,4,NOTE: Not required by code. Value provided by 90.1 Mechanical Subcommittee +90.1-2016,Open Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2016 Table 6.8.1-7 +90.1-2016,Open Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,40.2,From 90.1-2016 Table 6.8.1-7 +90.1-2016,Closed Cooling Tower,Centrifugal,9/9/1919,9/9/2999,7,From 90.1-2016 Table 6.8.1-7 +90.1-2016,Closed Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,16.1,From 90.1-2016 Table 6.8.1-7 +90.1-2016,Dry Cooler,Propeller or Axial,9/9/1919,9/9/2999,4,NOTE Not required by code. Value provided by 90.1 Mechanical Subcommittee +90.1-2019,Open Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2019 Table 6.8.1-7 +90.1-2019,Open Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,40.2,From 90.1-2019 Table 6.8.1-7 +90.1-2019,Closed Cooling Tower,Centrifugal,9/9/1919,9/9/2999,7,From 90.1-2019 Table 6.8.1-7 +90.1-2019,Closed Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,16.1,From 90.1-2019 Table 6.8.1-7 +90.1-2019,Dry Cooler,Propeller or Axial,9/9/1919,9/9/2999,4.5,From 90.1-2019 Table 6.8.1.7. Juan Gonzalez Added 01/11/2021 to account for fluid coolers in data center water loop heat pump condenser loops diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_motors_90_1.csv b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_motors_90_1.csv new file mode 100644 index 0000000000..986abcdab9 --- /dev/null +++ b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_motors_90_1.csv @@ -0,0 +1,148 @@ +template,number_of_poles,type,synchronous_speed,minimum_capacity,maximum_capacity,nominal_full_load_efficiency,annotation +90.1-2004,4,Enclosed,1800,0,0.999,0.29,"Motors below 1 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" +90.1-2004,4,Enclosed,1800,1,1.499,0.825,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,1.5,1.999,0.84,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,2,2.999,0.84,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,3,4.999,0.875,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,5,7.499,0.875,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,7.5,9.999,0.895,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,10,14.999,0.895,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,15,19.999,0.91,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,20,24.999,0.91,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,25,29.999,0.924,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,30,39.999,0.924,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,40,49.999,0.93,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,50,59.999,0.93,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,60,74.999,0.936,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,75,99.999,0.941,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,100,124.999,0.945,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,125,149.999,0.945,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,150,199.999,0.95,From 90.1-2004 Table 10.8 +90.1-2004,4,Enclosed,1800,200,9999,0.95,From 90.1-2004 Table 10.8 +90.1-2007,4,Enclosed,1800,0,0.999,0.29,"Motors below 1 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" +90.1-2007,4,Enclosed,1800,1,1.499,0.825,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,1.5,1.999,0.84,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,2,2.999,0.84,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,3,4.999,0.875,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,5,7.499,0.875,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,7.5,9.999,0.895,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,10,14.999,0.895,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,15,19.999,0.91,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,20,24.999,0.91,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,25,29.999,0.924,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,30,39.999,0.924,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,40,49.999,0.93,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,50,59.999,0.93,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,60,74.999,0.936,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,75,99.999,0.941,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,100,124.999,0.945,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,125,149.999,0.945,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,150,199.999,0.95,From 90.1-2007 Table 10.8 +90.1-2007,4,Enclosed,1800,200,9999,0.95,From 90.1-2007 Table 10.8 +90.1-2010,4,Enclosed,1800,0,0.999,0.29,"Motors below 1 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" +90.1-2010,4,Enclosed,1800,1,1.499,0.855,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,1.5,1.999,0.865,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,2,2.999,0.865,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,3,4.999,0.895,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,5,7.499,0.895,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,7.5,9.999,0.917,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,10,14.999,0.917,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,15,19.999,0.924,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,20,24.9999,0.93,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,25,29.999,0.936,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,30,39.999,0.936,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,40,49.999,0.941,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,50,59.999,0.945,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,60,74.999,0.95,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,75,99.999,0.954,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,100,124.999,0.954,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,125,149.999,0.954,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,150,199.999,0.958,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,200,249.999,0.962,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,250,299.999,0.962,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,300,349.999,0.962,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,350,399.999,0.962,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,400,449.999,0.962,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,450,499.999,0.962,From 90.1-2010 Table 10.8B +90.1-2010,4,Enclosed,1800,500,9999,0.962,From 90.1-2010 Table 10.8B +90.1-2013,4,Enclosed,1800,0,0.08333,0.29,"Motors below 1/12 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" +90.1-2013,4,Enclosed,1800,0.08334,0.999,0.7,"Motors between 1/12 and 1 HP must be EC, with minimum efficiency of 70% per PNNL" +90.1-2013,4,Enclosed,1800,1,1.499,0.855, +90.1-2013,4,Enclosed,1800,1.5,1.999,0.865, +90.1-2013,4,Enclosed,1800,2,2.999,0.865, +90.1-2013,4,Enclosed,1800,3,4.999,0.895, +90.1-2013,4,Enclosed,1800,5,7.499,0.895, +90.1-2013,4,Enclosed,1800,7.5,9.999,0.917, +90.1-2013,4,Enclosed,1800,10,14.999,0.917, +90.1-2013,4,Enclosed,1800,15,19.999,0.924, +90.1-2013,4,Enclosed,1800,20,24.999,0.93, +90.1-2013,4,Enclosed,1800,25,29.999,0.936, +90.1-2013,4,Enclosed,1800,30,39.999,0.936, +90.1-2013,4,Enclosed,1800,40,49.999,0.941, +90.1-2013,4,Enclosed,1800,50,59.999,0.945, +90.1-2013,4,Enclosed,1800,60,74.999,0.95, +90.1-2013,4,Enclosed,1800,75,99.999,0.954, +90.1-2013,4,Enclosed,1800,100,124.999,0.954, +90.1-2013,4,Enclosed,1800,125,149.999,0.954, +90.1-2013,4,Enclosed,1800,150,199.999,0.958, +90.1-2013,4,Enclosed,1800,200,249.999,0.962, +90.1-2013,4,Enclosed,1800,250,299.999,0.95, +90.1-2013,4,Enclosed,1800,300,349.999,0.954, +90.1-2013,4,Enclosed,1800,350,399.999,0.954, +90.1-2013,4,Enclosed,1800,400,449.999,0.954, +90.1-2013,4,Enclosed,1800,450,499.999,0.954, +90.1-2013,4,Enclosed,1800,500,9999,0.954, +90.1-2016,4,Enclosed,1800,0,0.08333,0.29,"Motors below 1/12 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" +90.1-2016,4,Enclosed,1800,0.08334,0.999,0.7,"Motors between 1/12 and 1 HP must be EC, with minimum efficiency of 70% per PNNL" +90.1-2016,4,Enclosed,1800,1,1.499,0.855, +90.1-2016,4,Enclosed,1800,1.5,1.999,0.865, +90.1-2016,4,Enclosed,1800,2,2.999,0.865, +90.1-2016,4,Enclosed,1800,3,4.999,0.895, +90.1-2016,4,Enclosed,1800,5,7.499,0.895, +90.1-2016,4,Enclosed,1800,7.5,9.999,0.917, +90.1-2016,4,Enclosed,1800,10,14.999,0.917, +90.1-2016,4,Enclosed,1800,15,19.999,0.924, +90.1-2016,4,Enclosed,1800,20,24.999,0.93, +90.1-2016,4,Enclosed,1800,25,29.999,0.936, +90.1-2016,4,Enclosed,1800,30,39.999,0.936, +90.1-2016,4,Enclosed,1800,40,49.999,0.941, +90.1-2016,4,Enclosed,1800,50,59.999,0.945, +90.1-2016,4,Enclosed,1800,60,74.999,0.95, +90.1-2016,4,Enclosed,1800,75,99.999,0.954, +90.1-2016,4,Enclosed,1800,100,124.999,0.954, +90.1-2016,4,Enclosed,1800,125,149.999,0.954, +90.1-2016,4,Enclosed,1800,150,199.999,0.958, +90.1-2016,4,Enclosed,1800,200,249.999,0.962, +90.1-2016,4,Enclosed,1800,250,299.999,0.962, +90.1-2016,4,Enclosed,1800,300,349.999,0.962, +90.1-2016,4,Enclosed,1800,350,399.999,0.962, +90.1-2016,4,Enclosed,1800,400,449.999,0.962, +90.1-2016,4,Enclosed,1800,450,499.999,0.962, +90.1-2016,4,Enclosed,1800,500,9999,0.962, +90.1-2019,4,Enclosed,1800,0,0.08333,0.29,"Motors below 1/12 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" +90.1-2019,4,Enclosed,1800,0.08334,0.999,0.7,"Motors between 1/12 and 1 HP must be EC, with minimum efficiency of 70% per PNNL" +90.1-2019,4,Enclosed,1800,1,1.499,0.855, +90.1-2019,4,Enclosed,1800,1.5,1.999,0.865, +90.1-2019,4,Enclosed,1800,2,2.999,0.865, +90.1-2019,4,Enclosed,1800,3,4.999,0.895, +90.1-2019,4,Enclosed,1800,5,7.499,0.895, +90.1-2019,4,Enclosed,1800,7.5,9.999,0.917, +90.1-2019,4,Enclosed,1800,10,14.999,0.917, +90.1-2019,4,Enclosed,1800,15,19.999,0.924, +90.1-2019,4,Enclosed,1800,20,24.999,0.93, +90.1-2019,4,Enclosed,1800,25,29.999,0.936, +90.1-2019,4,Enclosed,1800,30,39.999,0.936, +90.1-2019,4,Enclosed,1800,40,49.999,0.941, +90.1-2019,4,Enclosed,1800,50,59.999,0.945, +90.1-2019,4,Enclosed,1800,60,74.999,0.95, +90.1-2019,4,Enclosed,1800,75,99.999,0.954, +90.1-2019,4,Enclosed,1800,100,124.999,0.954, +90.1-2019,4,Enclosed,1800,125,149.999,0.954, +90.1-2019,4,Enclosed,1800,150,199.999,0.958, +90.1-2019,4,Enclosed,1800,200,249.999,0.962, +90.1-2019,4,Enclosed,1800,250,299.999,0.962, +90.1-2019,4,Enclosed,1800,300,349.999,0.962, +90.1-2019,4,Enclosed,1800,350,399.999,0.962, +90.1-2019,4,Enclosed,1800,400,449.999,0.962, +90.1-2019,4,Enclosed,1800,450,499.999,0.962, +90.1-2019,4,Enclosed,1800,500,9999,0.962, diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_unitary_air_conditioners_90_1.csv b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_unitary_air_conditioners_90_1.csv new file mode 100644 index 0000000000..51d10b80ba --- /dev/null +++ b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_unitary_air_conditioners_90_1.csv @@ -0,0 +1,196 @@ +template,cooling_type,heating_type,subcategory,minimum_capacity,maximum_capacity,start_date,end_date,minimum_seasonal_efficiency,minimum_energy_efficiency_ratio,minimum_integrated_part_load_value,minimum_integrated_energy_efficiency_ratio,ptac_eer_coefficient_1,ptac_eer_coefficient_2,minimum_scop,cool_cap_ft,cool_cap_fflow,cool_eir_ft,cool_eir_fflow,cool_plf_fplr,annotation +90.1-2004,AirCooled,All Other,PTAC,0,9999999,9/9/1919,9/9/2999,,,,,12.5,0.213,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2004,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,9.7,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,9.5,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,All Other,Single Package,240000,759999,9/9/1919,9/9/2999,,9.3,9.5,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,All Other,Single Package,760000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,10,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,9.5,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,All Other,Split System,240000,759999,9/9/1919,9/9/2999,,9.3,9.5,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,All Other,Split System,760000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,Electric Resistance or None,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.2,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2004 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" +90.1-2004,AirCooled,Electric Resistance or None,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.1,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2004 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" +90.1-2004,AirCooled,Electric Resistance or None,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,1.9,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2004 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" +90.1-2004,AirCooled,Electric Resistance or None,PTAC,0,9999999,9/9/1919,9/9/2999,,,,,12.5,0.213,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2004,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,9.7,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,10.3,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,9.7,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,Electric Resistance or None,Single Package,240000,759999,9/9/1919,9/9/2999,,9.5,9.7,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,Electric Resistance or None,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.2,9.4,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,10,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,10.3,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,9.7,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,Electric Resistance or None,Split System,240000,759999,9/9/1919,9/9/2999,,9.5,9.7,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,AirCooled,Electric Resistance or None,Split System,760000,9999999,9/9/1919,9/9/2999,,9.2,9.4,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2004,WaterCooled,All Other,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.6,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2004 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" +90.1-2004,WaterCooled,All Other,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.5,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2004 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" +90.1-2004,WaterCooled,All Other,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,2.4,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2004 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" +90.1-2007,AirCooled,All Other,PTAC,0,9999999,9/9/1919,9/9/2999,,,,,12.5,0.213,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2007,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,9.5,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,All Other,Single Package,240000,759999,9/9/1919,9/9/2999,,9.3,9.5,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,All Other,Single Package,760000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,9.5,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,All Other,Split System,240000,759999,9/9/1919,9/9/2999,,9.3,9.5,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,All Other,Split System,760000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,Electric Resistance or None,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.2,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2007 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" +90.1-2007,AirCooled,Electric Resistance or None,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.1,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2007 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" +90.1-2007,AirCooled,Electric Resistance or None,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,1.9,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2007 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" +90.1-2007,AirCooled,Electric Resistance or None,PTAC,0,9999999,9/9/1919,9/9/2999,,,,,12.5,0.213,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2007,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,10.3,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,9.7,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,Electric Resistance or None,Single Package,240000,759999,9/9/1919,9/9/2999,,9.5,9.7,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,Electric Resistance or None,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.2,9.4,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,10.3,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,9.7,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,Electric Resistance or None,Split System,240000,759999,9/9/1919,9/9/2999,,9.5,9.7,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,AirCooled,Electric Resistance or None,Split System,760000,9999999,9/9/1919,9/9/2999,,9.2,9.4,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, +90.1-2007,WaterCooled,All Other,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.6,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2007 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" +90.1-2007,WaterCooled,All Other,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.5,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2007 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" +90.1-2007,WaterCooled,All Other,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,2.4,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2007 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" +90.1-2010,AirCooled,All Other,PTAC,0,9999999,9/9/1919,9/9/2999,,,,,13.8,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2010,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2010,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,11,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2010,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,10.8,,,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, +90.1-2010,AirCooled,All Other,Single Package,240000,759999,9/9/1919,9/9/2999,,9.8,,9.7,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, +90.1-2010,AirCooled,All Other,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.5,,9.2,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, +90.1-2010,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2010,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,11,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2010,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,10.8,,,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, +90.1-2010,AirCooled,All Other,Split System,240000,759999,9/9/1919,9/9/2999,,9.8,,9.7,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, +90.1-2010,AirCooled,All Other,Split System,760000,9999999,9/9/1919,9/9/2999,,9.5,,9.2,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, +90.1-2010,AirCooled,Electric Resistance or None,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.2,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for downflow units +90.1-2010,AirCooled,Electric Resistance or None,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.1,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for downflow units +90.1-2010,AirCooled,Electric Resistance or None,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,1.9,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for downflow units +90.1-2010,AirCooled,Electric Resistance or None,PTAC,0,9999999,9/9/1919,9/9/2999,,,,,13.8,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2010,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2010,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,11.2,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2010,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,11,,,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, +90.1-2010,AirCooled,Electric Resistance or None,Single Package,240000,759999,9/9/1919,9/9/2999,,10,,9.7,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, +90.1-2010,AirCooled,Electric Resistance or None,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.7,,9.4,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, +90.1-2010,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2010,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,11.2,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2010,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,11,,,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, +90.1-2010,AirCooled,Electric Resistance or None,Split System,240000,759999,9/9/1919,9/9/2999,,10,,9.7,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, +90.1-2010,AirCooled,Electric Resistance or None,Split System,760000,9999999,9/9/1919,9/9/2999,,9.7,,9.4,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, +90.1-2010,WaterCooled,All Other,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.6,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units +90.1-2010,WaterCooled,All Other,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.5,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units +90.1-2010,WaterCooled,All Other,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,2.4,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units +90.1-2013,AirCooled,All Other,PTAC,0,9999999,9/9/1919,12/31/2014,,,,,13.8,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2013,AirCooled,All Other,PTAC,0,9999999,1/1/2015,9/9/2999,,,,,14,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2013,AirCooled,All Other,Single Package,0,64999,9/9/1919,12/31/2014,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Single Package,0,64999,1/1/2015,9/9/2999,14,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Single Package,65000,134999,9/9/1919,12/31/2015,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Single Package,135000,239999,9/9/1919,12/31/2015,,10.8,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Single Package,240000,759999,9/9/1919,12/31/2015,,9.8,,9.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Single Package,760000,9999999,9/9/1919,12/31/2015,,9.5,,9.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Single Package,65000,134999,1/1/2016,9/9/2999,,11,,12.7,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Single Package,135000,239999,1/1/2016,9/9/2999,,10.8,,12.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Single Package,240000,759999,1/1/2016,9/9/2999,,9.8,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Single Package,760000,9999999,1/1/2016,9/9/2999,,9.5,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Split System,65000,134999,9/9/1919,12/31/2015,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Split System,135000,239999,9/9/1919,12/31/2015,,10.8,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Split System,240000,759999,9/9/1919,12/31/2015,,9.8,,9.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Split System,760000,9999999,9/9/1919,12/31/2015,,9.5,,9.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Split System,65000,134999,1/1/2016,9/9/2999,,11,,12.7,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Split System,135000,239999,1/1/2016,9/9/2999,,10.8,,12.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Split System,240000,759999,1/1/2016,9/9/2999,,9.8,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,All Other,Split System,760000,9999999,1/1/2016,9/9/2999,,9.5,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.2,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units +90.1-2013,AirCooled,Electric Resistance or None,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.1,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units +90.1-2013,AirCooled,Electric Resistance or None,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,1.9,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units +90.1-2013,AirCooled,Electric Resistance or None,PTAC,0,9999999,9/9/1919,12/31/2014,,,,,13.8,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2013,AirCooled,Electric Resistance or None,PTAC,0,9999999,1/1/2015,9/9/2999,,,,,14,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2013,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,12/31/2014,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Single Package,0,64999,1/1/2015,9/9/2999,14,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,12/31/2015,,11.2,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,12/31/2015,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Single Package,240000,759999,9/9/1919,12/31/2015,,10,,10.1,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Single Package,760000,9999999,9/9/1919,12/31/2015,,9.7,,9.8,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Single Package,65000,134999,1/1/2016,9/9/2999,,11.2,,12.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Single Package,135000,239999,1/1/2016,9/9/2999,,11,,12.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Single Package,240000,759999,1/1/2016,9/9/2999,,10,,11.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Single Package,760000,9999999,1/1/2016,9/9/2999,,9.7,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,12/31/2015,,11.2,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,12/31/2015,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Split System,240000,759999,9/9/1919,12/31/2015,,10,,10.1,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Split System,760000,9999999,9/9/1919,12/31/2015,,9.7,,9.8,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Split System,65000,134999,1/1/2016,9/9/2999,,11.2,,12.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Split System,135000,239999,1/1/2016,9/9/2999,,11,,12.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Split System,240000,759999,1/1/2016,9/9/2999,,10,,11.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,AirCooled,Electric Resistance or None,Split System,760000,9999999,1/1/2016,9/9/2999,,9.7,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2013,WaterCooled,All Other,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.6,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units +90.1-2013,WaterCooled,All Other,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.5,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units +90.1-2013,WaterCooled,All Other,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,2.4,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units +90.1-2016,AirCooled,All Other,PTAC,0,9999999,9/9/1919,12/31/2014,,,,,13.8,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,All Other,PTAC,0,9999999,1/1/2015,9/9/2999,,,,,14,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,14,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,10.8,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,All Other,Single Package,240000,759999,9/9/1919,9/9/2999,,9.8,,9.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,All Other,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.5,,9.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,10.8,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,All Other,Split System,240000,759999,9/9/1919,9/9/2999,,9.8,,9.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,All Other,Split System,760000,9999999,9/9/1919,9/9/2999,,9.5,,9.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,Electric Resistance or None,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.3,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units +90.1-2016,AirCooled,Electric Resistance or None,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.2,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units +90.1-2016,AirCooled,Electric Resistance or None,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,2,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units +90.1-2016,AirCooled,Electric Resistance or None,PTAC,0,9999999,9/9/1919,12/31/2014,,,,,13.8,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,Electric Resistance or None,PTAC,0,9999999,1/1/2015,9/9/2999,,,,,14,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2016,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,12/31/2014,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,Electric Resistance or None,Single Package,0,64999,1/1/2015,9/9/2999,14,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,11.2,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,Electric Resistance or None,Single Package,240000,759999,9/9/1919,9/9/2999,,10,,10.1,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,Electric Resistance or None,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.7,,9.8,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,11.2,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,Electric Resistance or None,Split System,240000,759999,9/9/1919,9/9/2999,,10,,10.1,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,AirCooled,Electric Resistance or None,Split System,760000,9999999,9/9/1919,9/9/2999,,9.7,,9.8,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2016,WaterCooled,All Other,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.5,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units +90.1-2016,WaterCooled,All Other,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.4,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units +90.1-2016,WaterCooled,All Other,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,2.25,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units +90.1-2019,AirCooled,All Other,PTAC,0,6999,9/9/1919,9/9/2999,,11.9,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,PTAC,6999,14999,9/9/1919,9/9/2999,,,,,14,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,PTAC,14999,9999999,9/9/1919,9/9/2999,,9.5,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,14,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,11,,12.7,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,10.8,,12.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,All Other,Single Package,240000,759999,9/9/1919,9/9/2999,,9.8,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,All Other,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.5,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,11,,12.7,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,10.8,,12.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,All Other,Split System,240000,759999,9/9/1919,9/9/2999,,9.8,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,All Other,Split System,760000,9999999,9/9/1919,9/9/2999,,9.5,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,Electric Resistance or None,CRAC,0,79999,9/9/1919,9/9/2999,,,,,,,2.7,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for downflow units +90.1-2019,AirCooled,Electric Resistance or None,CRAC,80000,294999,9/9/1919,9/9/2999,,,,,,,2.58,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for downflow units +90.1-2019,AirCooled,Electric Resistance or None,CRAC,295000,9999999,9/9/1919,9/9/2999,,,,,,,2.36,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for downflow units +90.1-2019,AirCooled,Electric Resistance or None,PTAC,0,6999,9/9/1919,9/9/2999,,11.9,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,PTAC,6999,14999,9/9/1919,9/9/2999,,,,,14,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,PTAC,14999,9999999,9/9/1919,9/9/2999,,9.5,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, +90.1-2019,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,14,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,11.2,,12.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,11,,12.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,Electric Resistance or None,Single Package,240000,759999,9/9/1919,9/9/2999,,10,,11.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,Electric Resistance or None,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.7,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,11.2,,12.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,11,,12.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,Electric Resistance or None,Split System,240000,759999,9/9/1919,9/9/2999,,10,,11.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,AirCooled,Electric Resistance or None,Split System,760000,9999999,9/9/1919,9/9/2999,,9.7,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, +90.1-2019,WaterCooled,All Other,CRAC,0,79999,9/9/1919,9/9/2999,,,,,,,2.82,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for water cooled downflow units +90.1-2019,WaterCooled,All Other,CRAC,80000,294999,9/9/1919,9/9/2999,,,,,,,2.73,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for water cooled downflow units +90.1-2019,WaterCooled,All Other,CRAC,295000,9999999,9/9/1919,9/9/2999,,,,,,,2.67,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for water cooled downflow units diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_heaters_90_1.csv b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_heaters_90_1.csv new file mode 100644 index 0000000000..67ef79f434 --- /dev/null +++ b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_heaters_90_1.csv @@ -0,0 +1,25 @@ +template,fuel_type,minimum_capacity,maximum_capacity,start_date,end_date,energy_factor_base,energy_factor_volume_derate,standby_loss_base,standby_loss_capacity_allowance,standby_loss_volume_allowance,hourly_loss_base,hourly_loss_volume_allowance,thermal_efficiency,annotation +90.1-2004,Electricity,0,40945.99,9/9/1919,9/9/2999,0.93,0.00132,,,,,,,From 90.1-2004 Table 7.8 +90.1-2004,Electricity,40946,99999999,9/9/1919,9/9/2999,,,20,,35,,,,From 90.1-2004 Table 7.8 +90.1-2004,NaturalGas,0,74999.99,9/9/1919,9/9/2999,0.62,0.0019,,,,,,,From 90.1-2004 Table 7.8 +90.1-2004,NaturalGas,75000,99999999,9/9/1919,9/9/2999,,,,800,110,,,0.8,From 90.1-2004 Table 7.8 +90.1-2007,Electricity,0,40945.99,9/9/1919,9/9/2999,0.93,0.00132,,,,,,,From 90.1-2007 Table 7.8 +90.1-2007,Electricity,40946,99999999,9/9/1919,9/9/2999,,,20,,35,,,,From 90.1-2007 Table 7.8 +90.1-2007,NaturalGas,0,74999.99,9/9/1919,9/9/2999,0.62,0.0019,,,,,,,From 90.1-2007 Table 7.8 +90.1-2007,NaturalGas,75000,99999999,9/9/1919,9/9/2999,,,,800,110,,,0.8,From 90.1-2007 Table 7.8 +90.1-2010,Electricity,0,40945.99,9/9/1919,9/9/2999,0.97,0.00132,,,,,,,From 90.1-2010 Table 7.8 +90.1-2010,Electricity,40946,99999999,9/9/1919,9/9/2999,,,20,,35,,,,From 90.1-2010 Table 7.8 +90.1-2010,NaturalGas,0,74999.99,9/9/1919,9/9/2999,0.67,0.0019,,,,,,,From 90.1-2010 Table 7.8 +90.1-2010,NaturalGas,75000,99999999,9/9/1919,9/9/2999,,,,800,110,,,0.8,From 90.1-2010 Table 7.8 +90.1-2013,Electricity,0,40945.99,9/9/1919,9/9/2999,0.97,0.00132,,,,,,,From 90.1-2013 Table 7.8 +90.1-2013,Electricity,40946,99999999,9/9/1919,9/9/2999,,,,,,0.3,27,,From 90.1-2013 Table 7.8 +90.1-2013,NaturalGas,0,74999.99,9/9/1919,9/9/2999,0.67,0.0019,,,,,,,From 90.1-2013 Table 7.8 +90.1-2013,NaturalGas,75000,99999999,9/9/1919,9/9/2999,,,,800,110,,,0.8,From 90.1-2013 Table 7.8 +90.1-2016,Electricity,0,40945.99,9/9/1919,9/9/2999,0.96,0.0003,,,,,,,"From 90.1-2016 Table F-2, Rated Storage Volume <= 55 gal" +90.1-2016,Electricity,40946,99999999,9/9/1919,9/9/2999,,,,,,0.3,27,, +90.1-2016,NaturalGas,0,74999.99,9/9/1919,9/9/2999,0.675,0.0015,,,,,,,"From 90.1-2016 Table F-2, Rated Storage Volume <= 55 gal" +90.1-2016,NaturalGas,75000,99999999,9/9/1919,9/9/2999,,,,800,110,,,0.8, +90.1-2019,Electricity,0,40945.99,9/9/1919,9/9/2999,0.96,0.0003,,,,,,,Same as 90.1-2016 as placeholder; 90.1-2019 Table F-2 uses UEF +90.1-2019,Electricity,40946,99999999,9/9/1919,9/9/2999,,,,,,0.3,27,, +90.1-2019,NaturalGas,0,74999.99,9/9/1919,9/9/2999,0.675,0.0015,,,,,,,Same as 90.1-2016 as placeholder; 90.1-2019 Table F-2 uses UEF +90.1-2019,NaturalGas,75000,99999999,9/9/1919,9/9/2999,,,,800,110,,,0.8, diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1.csv b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1.csv new file mode 100644 index 0000000000..3ef18bfab7 --- /dev/null +++ b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1.csv @@ -0,0 +1,19 @@ +template,minimum_capacity,maximum_capacity,start_date,end_date,minimum_full_load_efficiency,annotation +90.1-2004,0,16999,9/9/1919,9/9/2999,11.2,From 90.1-2004 Table 6.8.1B +90.1-2004,17000,64999,9/9/1919,9/9/2999,12,From 90.1-2004 Table 6.8.1B +90.1-2004,65000,134999,9/9/1919,9/9/2999,12,From 90.1-2004 Table 6.8.1B +90.1-2007,0,16999,9/9/1919,9/9/2999,11.2,From 90.1-2007 Table 6.8.1B +90.1-2007,17000,64999,9/9/1919,9/9/2999,12,From 90.1-2007 Table 6.8.1B +90.1-2007,65000,134999,9/9/1919,9/9/2999,12,From 90.1-2007 Table 6.8.1B +90.1-2010,0,16999,9/9/1919,9/9/2999,11.2,From 90.1-2010 Table 6.8.1B +90.1-2010,17000,64999,9/9/1919,9/9/2999,12,From 90.1-2010 Table 6.8.1B +90.1-2010,65000,134999,9/9/1919,9/9/2999,12,From 90.1-2010 Table 6.8.1B +90.1-2013,0,16999,9/9/1919,9/9/2999,12.2,From 90.1-2013 Table 6.8.1-2 +90.1-2013,17000,64999,9/9/1919,9/9/2999,13,From 90.1-2013 Table 6.8.1-2 +90.1-2013,65000,134999,9/9/1919,9/9/2999,13,From 90.1-2013 Table 6.8.1-2 +90.1-2016,0,16999,9/9/1919,9/9/2999,12.2, +90.1-2016,17000,64999,9/9/1919,9/9/2999,13, +90.1-2016,65000,134999,9/9/1919,9/9/2999,13, +90.1-2019,0,16999,9/9/1919,9/9/2999,12.2, +90.1-2019,17000,64999,9/9/1919,9/9/2999,13, +90.1-2019,65000,134999,9/9/1919,9/9/2999,13, diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_source_heat_pumps_heating_90_1.csv b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_source_heat_pumps_heating_90_1.csv new file mode 100644 index 0000000000..2359b75f6d --- /dev/null +++ b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_source_heat_pumps_heating_90_1.csv @@ -0,0 +1,7 @@ +template,minimum_capacity,maximum_capacity,start_date,end_date,minimum_coefficient_of_performance,annotation +90.1-2004,0,9999999,9/9/1919,9/9/2999,4.2,From 90.1-2004 Table 6.8.1B +90.1-2007,0,9999999,9/9/1919,9/9/2999,4.2,From 90.1-2007 Table 6.8.1B +90.1-2010,0,9999999,9/9/1919,9/9/2999,4.2,From 90.1-2010 Table 6.8.1B +90.1-2013,0,9999999,9/9/1919,9/9/2999,4.3,From 90.1-2013 Table 6.8.1-2 +90.1-2016,0,9999999,9/9/1919,9/9/2999,4.3,From 90.1-2016 Table 6.8.1-2 +90.1-2019,0,9999999,9/9/1919,9/9/2999,4.3,From 90.1-2016 Table 6.8.1-15 diff --git a/data/openstudio_standards_data/database_files/level_1_space_types.csv b/data/openstudio_standards_data/database_files/level_1_space_types.csv new file mode 100644 index 0000000000..0a94c3c794 --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_1_space_types.csv @@ -0,0 +1,129 @@ +space_type_name,lighting_space_type_name,ventilation_space_type_name,electric_equipment_space_type_name +chapel - visually impaired,chapel_visually_impaired,public_assembly_spaces_religious_workshop, +recreation/common living - visually impaired,recreation_common_living_visually_impaired,hotels_motels_resorts_dormitories_multi_purpose_assembly, +atrium < 20 ft height,atrium_low,office_buildings_main_entry_lobbies,atrium < 20 ft height +atrium >= 20 ft and <= 40 ft in height,atrium_medium,office_buildings_main_entry_lobbies,atrium >= 20 ft and <= 40 ft in height +atrium > 40 ft height,atrium_high,office_buildings_main_entry_lobbies,atrium > 40 ft height +audience seating - convention center,audience_seating_convention_center,public_assembly_spaces_auditorium_seating_area,audience seating - convention center +audience seating - exercise center,audience_seating_exercise_center,sports_entertainment_spectator_areas,audience seating - exercise center +audience seating - all other,audience_seating_general,public_assembly_spaces_auditorium_seating_area,audience seating - all other +audience seating - auditorium,audience_seating_auditorium,public_assembly_spaces_auditorium_seating_area,audience seating - auditorium +audience seating - gymnasium,audience_seating_gymnasium,sports_entertainment_spectator_areas,audience seating - gymnasium +audience seating - sports arena,audience_seating_sports_arena,sports_entertainment_spectator_areas,audience seating - sports arena +audience seating - motion picture theater,audience_seating_motion_picture_theater,public_assembly_spaces_auditorium_seating_area,audience seating - motion picture theater +audience seating - penitentiary,audience_seating_penitentiary,public_assembly_spaces_auditorium_seating_area, +audience seating - performing arts theater,audience_seating_performing_arts_theater,public_assembly_spaces_auditorium_seating_area,audience seating - performing arts theater +audience seating - religious facility,audience_seating_religious_facility,public_assembly_spaces_auditorium_seating_area,audience seating - religious facility +audience seating - transportation facility,audience_seating_transportation,public_assembly_spaces_auditorium_seating_area, +automotive,automotive,miscellaneous_spaces_transportation_waiting, +banking activity,banking_activity,miscellaneous_spaces_banks_bank_lobbies,banking activity +classroom/lecture/training - all other,classroom_lecture_training_general,educational_facilities_classroom_old,classroom/lecture/training - all other +classroom/lecture/training - penitentiary,classroom_lecture_training_penitentiary,correctional_facilities_dayroom,classroom/lecture/training - penitentiary +classroom - laboratory or shop,laboratory_classroom,educational_facilities_university_college_laboratories, +classroom/lecture/training - preschool to 12th,classroom_lecture_training_general,educational_facilities_classroom_young,classroom/lecture/training - preschool to 12th +computer room,computer_room,miscellaneous_spaces_computer,computer room +conference/meeting/multipurpose,conference_meeting_multipurpose,general_conference_meeting,conference/meeting/multipurpose +confinement cells,confinement_cells,correctional_facilities_cell,confinement cells +exhibit - convention center,exhibit_convention_center,public_assembly_spaces_museums_galleries,exhibit - convention center +copy/print,copy_print,office_buildings_telephone_data_entry, +corridor for visually impaired,corridor_visually_impaired,general_conference_corridors, +corridor - hospital,corridor_hospital,general_conference_corridors,corridor - hospital +corridor - manufacturing facility,corridor_manufacturing_facility,general_conference_corridors,corridor - manufacturing facility +corridor - all other,corridor_general,general_conference_corridors,corridor - all other +courtroom,courtroom,public_assembly_spaces_courtrooms,courtroom +dining - all other,dining_general,food_beverage_service_restaurant_dining_rooms,dining - all other +dining - bar/lounge/leisure,dining_bar_lounge_leisure,food_beverage_service_bars_cocktail_lounges,dining - bar/lounge/leisure +dining - cafeteria/fast food,dining_cafeteria_fast_food,food_beverage_service_cafeteria_fast_food_dining,dining - cafeteria/fast food +dining for visually impaired,dining_visually_impaired,food_beverage_service_restaurant_dining_rooms, +dining - family,dining_family,food_beverage_service_restaurant_dining_rooms,dining - family +dining - penitentiary,dining_penitentiary,food_beverage_service_restaurant_dining_rooms,dining - penitentiary +dining - hotel,dining_hotel,food_beverage_service_restaurant_dining_rooms, +dining - motel,dining_motel,food_beverage_service_restaurant_dining_rooms, +dormitory - living quarters,dormitory_living_quarters,hotels_motels_resorts_dormitories_bedroom_living_room,dormitory - living quarters +electrical/mechanical,electrical_mechanical,miscellaneous_spaces_manufacturing_wo_hazardous_materials,electrical/mechanical +emergency vehicle garage,emergency_vehicle_garage,miscellaneous_spaces_transportation_waiting,emergency vehicle garage +firestation - sleeping quarters,firestation_sleeping_quarters,hotels_motels_resorts_dormitories_barracks_sleeping_areas,firestation - sleeping quarters +kitchen,kitchen,food_beverage_service_kitchen,kitchen +guest room,guest_room,hotels_motels_resorts_dormitories_barracks_sleeping_areas,guest room +gymnasium exercise area,gymnasium_exercise_area,sports_entertainment_gym_stadium,gymnasium exercise area +gymnasium playing area,gymnasium_playing_area,sports_entertainment_gym_stadium,gymnasium playing area +emergency room,emergency_room,outpatient_health_care_facilities_general_examination_room,emergency room +exam/treatment,exam_treatment,outpatient_health_care_facilities_general_examination_room,exam/treatment +imaging,imaging,outpatient_health_care_facilities_class_1_imaging_rooms, +medical supply,medical_supply,miscellaneous_spaces_pharmacy, +nursery,nursery,outpatient_health_care_facilities_psychiatric_consultation_room, +nurses station,nurses_station,outpatient_health_care_facilities_psychiatric_consultation_room,nurses station +operating room,operating_room,outpatient_health_care_facilities_general_examination_room,operating room +patient room,patient_room,outpatient_health_care_facilities_physical_therapy_individual_room,patient room +physical therapy,physical_therapy,outpatient_health_care_facilities_physical_therapy_exercise_area,physical therapy +recovery,recovery,outpatient_health_care_facilities_urgent_care_examination_room, +judges chambers,judges_chambers,public_assembly_spaces_legislative_chambers,judges chambers +laboratory,laboratory_all_other,educational_facilities_science_laboratories,laboratory +library - reading,library_reading,public_assembly_spaces_libraries,library - reading +library - stacks,library_stacks,public_assembly_spaces_libraries,library - stacks +library - cataloging,library_cataloging,public_assembly_spaces_libraries,library - cataloging +loading dock,loading_dock,miscellaneous_spaces_sorting_packing_light_assembly, +lobby - all other,lobby_general,public_assembly_spaces_lobbies,lobby - all other +lobby - elevator,lobby_elevator,public_assembly_spaces_lobbies,lobby - elevator +lobby for visually impaired,lobby_visually_impaired,public_assembly_spaces_lobbies, +lobby - hotel,lobby_hotel,hotels_motels_resorts_dormitories_lobbies_prefunction,lobby - hotel +lobby - motion picture theater,lobby_motion_picture_theater,public_assembly_spaces_lobbies,lobby - motion picture theater +lobby - performing arts theater,lobby_performing_arts_theater,public_assembly_spaces_lobbies,lobby - performing arts theater +locker room,locker_room,general_break_rooms,locker room +lounge/breakroom - all other,lounge_breakroom_general,general_break_rooms,lounge/breakroom - all other +lounge/breakroom - healthcare facility,lounge_breakroom_healthcare_facility,general_break_rooms,lounge/breakroom - healthcare facility +laundry/washing,laundry_washing,hotels_motels_resorts_dormitories_laundry_rooms,laundry/washing +detailed manufacuring,detailed_manufacuring,miscellaneous_spaces_manufacturing_wo_hazardous_materials, +manufacturing equipment room,manufacturing_equipment_room,miscellaneous_spaces_manufacturing_wo_hazardous_materials,manufacturing equipment room +manufacturing extra high bay,manufacturing_extra_high_bay,miscellaneous_spaces_manufacturing_wo_hazardous_materials, +manufacturing high bay,manufacturing_high_bay,miscellaneous_spaces_manufacturing_wo_hazardous_materials, +manufacturing low bay,manufacturing_low_bay,miscellaneous_spaces_manufacturing_wo_hazardous_materials,manufacturing low bay +manufacturing control,manufacturing_control,miscellaneous_spaces_manufacturing_wo_hazardous_materials, +museum exhibit area,museum_exhibit_area,public_assembly_spaces_museums_galleries,museum exhibit area +museum restoration,museum_restoration,public_assembly_spaces_museums_galleries,museum restoration +performing arts dressing room,performing_arts_dressing_room,retail_mall_common_areas,performing arts dressing room +office - enclosed <= 250 sf,office_enclosed_small,office_buildings_office_space,office - enclosed <= 250 sf +office - enclosed > 250 sf,office_enclosed_large,office_buildings_office_space,office - enclosed > 250 sf +office - open,office_open,office_buildings_office_space,office - open +"parking area, interior",parking_area_interior,miscellaneous_spaces_transportation_waiting,"parking area, interior" +pharmacy,pharmacy,miscellaneous_spaces_pharmacy,pharmacy +post office - sorting area,post_office_sorting_area,miscellaneous_spaces_sorting_packing_light_assembly,post office - sorting area +fellowship hall - religious facility,fellowship_hall_religious_facility,public_assembly_spaces_religious_workshop,fellowship hall - religious facility +worship/pulpit/choir area,worship_pulpit_choir_area,public_assembly_spaces_religious_workshop,worship/pulpit/choir area +restroom - all other,restroom_all_other,,restroom - all other +restroom - visually impaired,restroom_visually_impaired,, +retail dressing room,retail_dressing_room,retail_mall_common_areas, +retail mall concourse,retail_mall_concourse,retail_mall_common_areas, +"seating area, general",seating_area_general,public_assembly_spaces_auditorium_seating_area,"seating area, general" +"sports arena playing area, class I",sports_arena_playing_area_class_I,sports_entertainment_sports_arena, +"sports arena playing area, class II",sports_arena_playing_area_class_II,sports_entertainment_sports_arena,"sports arena playing area, class II" +"sports arena playing area, class III",sports_arena_playing_area_class_III,sports_entertainment_sports_arena, +"sports arena playing area, class IV",sports_arena_playing_area_class_IV,sports_entertainment_sports_arena,"sports arena playing area, class IV" +sports arena - ring sports area,sports_arena_ring_sports_area,sports_entertainment_sports_arena, +sports arena - court sports area,sports_arena_court_sports_area,sports_entertainment_sports_arena, +sports arena - indoor playing field,sports_arena_indoor_playing_field,sports_entertainment_sports_arena, +stairwell,stairwell,general_conference_corridors,stairwell +storage < 50 sf - all other,storage_ all_other_small,general_conference_storage_rooms,storage < 50 sf - all other +storage 50 to 1000 sf - all other,storage_ all_other_large,general_conference_storage_rooms,storage 50 to 1000 sf - all other +storage < 50 sf - hospital,storage_hospital_small,general_conference_storage_rooms,storage < 50 sf - hospital +storage 50 to 1000 sf - hospital,storage_hospital_large,general_conference_storage_rooms,storage 50 to 1000 sf - hospital +storage - inactive,storage_inactive,general_conference_storage_rooms,storage - inactive +"storage, inactive - museum",storage_inactive_museum,general_conference_storage_rooms, +airport concourse,airport_concourse,office_buildings_reception_areas,airport concourse +baggage/carousel,baggage_carousel,office_buildings_reception_areas,baggage/carousel +transportation ticket counter,transportation_ticket_counter,office_buildings_reception_areas,transportation ticket counter +vehicular maintenance,vehicular_maintenance,miscellaneous_spaces_manufacturing_wo_hazardous_materials,vehicular maintenance +warehouse - bulk storage,warehouse_bulk_storage,miscellaneous_spaces_warehouses,warehouse - bulk storage +warehouse - fine storage,warehouse_fine_storage,miscellaneous_spaces_warehouses,warehouse - fine storage +workshop,workshop,miscellaneous_spaces_manufacturing_wo_hazardous_materials,workshop +sales,sales,retail_sales,sales +sales - display type 1,sales_display_type_1,retail_sales, +sales - display type 2,sales_display_type_2,retail_sales, +sales - display type 3,sales_display_type_3,retail_sales, +sales - display type 4,sales_display_type_4,retail_sales, +guest room - highway,guest_room,hotels_motels_resorts_dormitories_barracks_sleeping_areas, +lodging dining - highway,dining_general,food_beverage_service_restaurant_dining_rooms, +audience seating - classroom/lecture/training,audience_seating_general,public_assembly_spaces_auditorium_seating_area, +audience seating - conference/meeting/multipurpose,audience_seating_general,public_assembly_spaces_auditorium_seating_area, +audience seating - corridor/transition,audience_seating_general,public_assembly_spaces_auditorium_seating_area, +guest room - bathroom,guest_room,hotels_motels_resorts_dormitories_barracks_sleeping_areas, diff --git a/data/openstudio_standards_data/database_files/level_2_electric_equipment.csv b/data/openstudio_standards_data/database_files/level_2_electric_equipment.csv new file mode 100644 index 0000000000..5a49077ef2 --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_2_electric_equipment.csv @@ -0,0 +1,91 @@ +electric_equipment_space_type_name,electric_equipment_minimum_epd,electric_equipment_average_epd,electric_equipment_median_epd,electric_equipment_maximum_epd,electric_equipment_epd_unit +corridor - all other,0,0.28,0.24,0.82,W/ft2 +dining - all other,0.32,0.55,0.55,0.82,W/ft2 +electrical/mechanical,0,0,0,0,W/ft2 +kitchen,0.3,0.76,0.71,2.52,W/ft2 +laboratory,0.49,0.78,0.7,2.02,W/ft2 +lobby - all other,0.16,0.41,0.35,0.83,W/ft2 +locker room,0,0.38,0.44,0.97,W/ft2 +lounge/breakroom - all other,0,0.49,0.52,0.88,W/ft2 +office - enclosed <= 250 sf,0.51,0.68,0.68,0.89,W/ft2 +office - enclosed > 250 sf,0.65,0.7,0.69,0.82,W/ft2 +office - open,0.53,0.66,0.67,0.81,W/ft2 +restroom - all other,0,0,0,0,W/ft2 +stairwell,0,0.25,0.25,0.53,W/ft2 +storage < 50 sf - all other,0,0,0,0,W/ft2 +storage 50 to 1000 sf - all other,0,0,0,0,W/ft2 +vehicular maintenance,0.65,0.69,0.69,0.73,W/ft2 +workshop,0,0.54,0.57,0.74,W/ft2 +atrium - first three floors,0,0.52,0.54,0.75,W/ft2 +audience seating - convention center,0.63,0.63,0.63,0.63,W/ft2 +classroom/lecture/training - all other,0.5,0.63,0.62,0.8,W/ft2 +conference/meeting/multipurpose,0.42,0.62,0.62,0.97,W/ft2 +exhibit - convention center,0.84,0.84,0.84,0.84,W/ft2 +gymnasium exercise area,0.27,0.48,0.49,0.68,W/ft2 +gymnasium playing area,0,0.51,0.51,1.06,W/ft2 +laundry/washing,0,0.39,0.39,0.59,W/ft2 +lobby - elevator,0.32,0.32,0.32,0.32,W/ft2 +nurses station,0,0.52,0.57,0.85,W/ft2 +post office - sorting area,0,0.23,0.24,0.39,W/ft2 +sales,0.41,0.67,0.67,0.92,W/ft2 +"sports arena playing area, class IV",0.32,0.5,0.64,0.69,W/ft2 +audience seating - all other,0.31,0.49,0.46,0.75,W/ft2 +confinement cells,0.22,0.26,0.26,0.32,W/ft2 +courtroom,0.25,0.4,0.4,0.56,W/ft2 +judges chambers,0.5,0.59,0.59,0.68,W/ft2 +library - stacks,0,0.2,0.2,0.33,W/ft2 +storage - inactive,0,0,0,0,W/ft2 +dining - bar/lounge/leisure,0.5,0.5,0.5,0.5,W/ft2 +dining - cafeteria/fast food,0.6,0.6,0.6,0.6,W/ft2 +dining - family,0.78,0.78,0.78,0.78,W/ft2 +computer room,0.69,0.7,0.69,0.73,W/ft2 +dormitory - living quarters,0.23,0.44,0.42,0.62,W/ft2 +audience seating - exercise center,0.6,0.6,0.6,0.6,W/ft2 +exam/treatment,0.51,0.56,0.53,0.66,W/ft2 +library - reading,0.32,0.49,0.46,0.71,W/ft2 +emergency vehicle garage,0.39,0.39,0.39,0.39,W/ft2 +firestation - sleeping quarters,0.37,0.37,0.37,0.37,W/ft2 +"parking area, interior",0.11,0.27,0.3,0.32,W/ft2 +audience seating - gymnasium,0.64,0.64,0.64,0.64,W/ft2 +emergency room,0.61,0.62,0.62,0.62,W/ft2 +patient room,0.71,0.72,0.72,0.73,W/ft2 +pharmacy,0.47,0.64,0.72,0.74,W/ft2 +corridor - hospital,0.3,0.3,0.3,0.3,W/ft2 +fellowship hall - religious facility,0.36,0.39,0.39,0.41,W/ft2 +lounge/breakroom - healthcare facility,0.75,0.75,0.75,0.75,W/ft2 +operating room,0.77,0.77,0.77,0.77,W/ft2 +physical therapy,0.73,0.73,0.73,0.73,W/ft2 +storage < 50 sf - hospital,0,0,0,0,W/ft2 +storage 50 to 1000 sf - hospital,0,0,0,0,W/ft2 +guest room,0.47,0.53,0.53,0.58,W/ft2 +lobby - hotel,0.5,0.5,0.5,0.5,W/ft2 +library - cataloging,0.21,0.21,0.21,0.21,W/ft2 +museum exhibit area,0.32,0.46,0.43,0.68,W/ft2 +corridor - manufacturing facility,0.38,0.38,0.38,0.38,W/ft2 +manufacturing equipment room,0,0,0,0,W/ft2 +manufacturing low bay,0.67,0.67,0.67,0.67,W/ft2 +performing arts dressing room,0.29,0.41,0.43,0.5,W/ft2 +audience seating - auditorium,0.26,0.29,0.29,0.32,W/ft2 +audience seating - motion picture theater,0.28,0.28,0.28,0.28,W/ft2 +lobby - motion picture theater,0.33,0.33,0.33,0.33,W/ft2 +Dwelling Unit,0.25,0.25,0.25,0.25,W/ft2 +museum restoration,0.21,0.21,0.21,0.21,W/ft2 +banking activity,0.54,0.55,0.55,0.56,W/ft2 +warehouse - fine storage,0,0.06,0.06,0.12,W/ft2 +classroom/lecture/training - penitentiary,0.41,0.41,0.41,0.41,W/ft2 +dining - penitentiary,0.35,0.35,0.35,0.35,W/ft2 +audience seating - performing arts theater,0.27,0.27,0.27,0.27,W/ft2 +lobby - performing arts theater,0.33,0.33,0.33,0.33,W/ft2 +audience seating - religious facility,0.41,0.41,0.41,0.41,W/ft2 +worship/pulpit/choir area,0.42,0.42,0.42,0.42,W/ft2 +classroom/lecture/training - preschool to 12th,0.67,0.67,0.67,0.67,W/ft2 +"sports arena playing area, class II",0.32,0.48,0.48,0.64,W/ft2 +audience seating - sports arena,0.38,0.38,0.38,0.38,W/ft2 +airport concourse,0.52,0.52,0.52,0.52,W/ft2 +atrium < 20 ft height,0.53,0.53,0.53,0.53,W/ft2 +atrium > 40 ft height,0.53,0.53,0.53,0.53,W/ft2 +atrium >= 20 ft and <= 40 ft in height,0.53,0.53,0.53,0.53,W/ft2 +baggage/carousel,0.55,0.55,0.55,0.55,W/ft2 +"seating area, general",0.25,0.25,0.25,0.25,W/ft2 +transportation ticket counter,0.74,0.74,0.74,0.74,W/ft2 +warehouse - bulk storage,0.11,0.11,0.11,0.11,W/ft2 diff --git a/data/openstudio_standards_data/database_files/level_2_lighting_space_types.csv b/data/openstudio_standards_data/database_files/level_2_lighting_space_types.csv new file mode 100644 index 0000000000..ff4290bc11 --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_2_lighting_space_types.csv @@ -0,0 +1,287 @@ +lighting_space_type_name,level_3_lighting_definition_table,level_3_lighting_defintion_id +bam_automotive_facility,level_3_lighting_90_1_2004,1 +bam_convention_center,level_3_lighting_90_1_2004,2 +bam_courthouse,level_3_lighting_90_1_2004,3 +bam_dinin_bar_lounge_leisure,level_3_lighting_90_1_2004,4 +bam_dining_cafeteria_fast_food,level_3_lighting_90_1_2004,5 +bam_dining_family,level_3_lighting_90_1_2004,6 +bam_dormitory,level_3_lighting_90_1_2004,7 +bam_exercise_center,level_3_lighting_90_1_2004,8 +bam_fire_station,level_3_lighting_90_1_2004,23 +bam_gymnasium,level_3_lighting_90_1_2004,9 +bam_healthcare_clinic,level_3_lighting_90_1_2004,10 +bam_hospital,level_3_lighting_90_1_2004,11 +bam_hotel,level_3_lighting_90_1_2004,12 +bam_library,level_3_lighting_90_1_2004,13 +bam_manufacturing_facility,level_3_lighting_90_1_2004,14 +bam_motel,level_3_lighting_90_1_2004,15 +bam_motion_picture_theater,level_3_lighting_90_1_2004,16 +bam_multifamily,level_3_lighting_90_1_2004,17 +bam_museum,level_3_lighting_90_1_2004,18 +bam_office,level_3_lighting_90_1_2004,19 +bam_parking_garage,level_3_lighting_90_1_2004,20 +bam_penitentiary,level_3_lighting_90_1_2004,21 +bam_performing_arts_theater,level_3_lighting_90_1_2004,22 +bam_police_station,level_3_lighting_90_1_2004,23 +bam_post_office,level_3_lighting_90_1_2004,24 +bam_religious_facility,level_3_lighting_90_1_2004,25 +bam_retail,level_3_lighting_90_1_2004,26 +bam_school_university,level_3_lighting_90_1_2004,27 +bam_sports_arena,level_3_lighting_90_1_2004,28 +bam_town_hall,level_3_lighting_90_1_2004,29 +bam_transportation,level_3_lighting_90_1_2004,30 +bam_warehouse,level_3_lighting_90_1_2004,31 +bam_workshop,level_3_lighting_90_1_2004,32 +office_enclosed_small,level_3_lighting_90_1_2004,33 +office_enclosed_large,level_3_lighting_90_1_2004,33 +office_open,level_3_lighting_90_1_2004,34 +conference_meeting_multipurpose,level_3_lighting_90_1_2004,35 +classroom_lecture_training_general,level_3_lighting_90_1_2004,36 +classroom_lecture_training_penitentiary,level_3_lighting_90_1_2004,37 +lobby_general,level_3_lighting_90_1_2004,38 +lobby_hotel,level_3_lighting_90_1_2004,39 +lobby_performing_arts_theater,level_3_lighting_90_1_2004,40 +lobby_motion_picture_theater,level_3_lighting_90_1_2004,41 +lobby_visually_impaired,level_3_lighting_90_1_2004,38 +lobby_elevator,level_3_lighting_90_1_2004,38 +audience_seating_general,level_3_lighting_90_1_2004,42 +audience_seating_gymnasium,level_3_lighting_90_1_2004,43 +audience_seating_exercise_center,level_3_lighting_90_1_2004,44 +audience_seating_convention_center,level_3_lighting_90_1_2004,45 +audience_seating_penitentiary,level_3_lighting_90_1_2004,46 +audience_seating_religious_facility,level_3_lighting_90_1_2004,47 +audience_seating_sports_arena,level_3_lighting_90_1_2004,48 +audience_seating_performing_arts_theater,level_3_lighting_90_1_2004,49 +audience_seating_motion_picture_theater,level_3_lighting_90_1_2004,50 +audience_seating_transportation,level_3_lighting_90_1_2004,51 +audience_seating_auditorium,level_3_lighting_90_1_2004,42 +atrium_first_three_floor,level_3_lighting_90_1_2004,52 +atrium_each_additional_floor,level_3_lighting_90_1_2004,53 +lounge_breakroom_general,level_3_lighting_90_1_2004,54 +lounge_breakroom_healthcare_facility,level_3_lighting_90_1_2004,55 +dining_general,level_3_lighting_90_1_2004,56 +dining_penitentiary,level_3_lighting_90_1_2004,57 +dining_hotel,level_3_lighting_90_1_2004,58 +dining_motel,level_3_lighting_90_1_2004,59 +dining_bar_lounge_leisure,level_3_lighting_90_1_2004,60 +dining_family,level_3_lighting_90_1_2004,61 +dining_cafeteria_fast_food,level_3_lighting_90_1_2004,56 +dining_visually_impaired,level_3_lighting_90_1_2004,56 +kitchen,level_3_lighting_90_1_2004,62 +laboratory_classroom,level_3_lighting_90_1_2004,63 +laboratory_all_other,level_3_lighting_90_1_2004,63 +restroom_visually_impaired,level_3_lighting_90_1_2004,64 +restroom_all_other,level_3_lighting_90_1_2004,64 +performing_arts_dressing_room,level_3_lighting_90_1_2004,65 +corridor_general,level_3_lighting_90_1_2004,66 +corridor_hospital,level_3_lighting_90_1_2004,67 +corridor_manufacturing_facility,level_3_lighting_90_1_2004,68 +corridor_visually_impaired,level_3_lighting_90_1_2004,66 +stairway,level_3_lighting_90_1_2004,69 +stairwell,level_3_lighting_90_1_2004,69 +storage_ all_other_small,level_3_lighting_90_1_2004,70 +storage_ all_other_large,level_3_lighting_90_1_2004,70 +storage_hospital_small,level_3_lighting_90_1_2004,71 +storage_hospital_large,level_3_lighting_90_1_2004,71 +storage_inactive,level_3_lighting_90_1_2004,72 +storage_inactive_museum,level_3_lighting_90_1_2004,73 +electrical_mechanical,level_3_lighting_90_1_2004,74 +workshop,level_3_lighting_90_1_2004,75 +gymnasium_playing_area,level_3_lighting_90_1_2004,76 +gymnasium_exercise_area,level_3_lighting_90_1_2004,77 +courtroom,level_3_lighting_90_1_2004,78 +confinement_cells,level_3_lighting_90_1_2004,79 +judges_chambers,level_3_lighting_90_1_2004,80 +emergency_vehicle_garage,level_3_lighting_90_1_2004,81 +firestation_sleeping_quarters,level_3_lighting_90_1_2004,82 +post_office_sorting_area,level_3_lighting_90_1_2004,83 +exhibit_convention_center,level_3_lighting_90_1_2004,84 +library_cataloging,level_3_lighting_90_1_2004,85 +library_stacks,level_3_lighting_90_1_2004,86 +library_reading,level_3_lighting_90_1_2004,87 +emergency_room,level_3_lighting_90_1_2004,88 +recovery,level_3_lighting_90_1_2004,89 +nurses_station,level_3_lighting_90_1_2004,90 +exam_treatment,level_3_lighting_90_1_2004,91 +pharmacy,level_3_lighting_90_1_2004,92 +patient_room,level_3_lighting_90_1_2004,93 +operating_room,level_3_lighting_90_1_2004,94 +nursery,level_3_lighting_90_1_2004,95 +medical_supply,level_3_lighting_90_1_2004,96 +physical_therapy,level_3_lighting_90_1_2004,97 +imaging,level_3_lighting_90_1_2004,98 +laundry_washing,level_3_lighting_90_1_2004,99 +automotive,level_3_lighting_90_1_2004,100 +manufacturing_low_bay,level_3_lighting_90_1_2004,101 +manufacturing_high_bay,level_3_lighting_90_1_2004,102 +detailed_manufacuring,level_3_lighting_90_1_2004,103 +manufacturing_equipment_room,level_3_lighting_90_1_2004,104 +manufacturing_control,level_3_lighting_90_1_2004,105 +guest_room,level_3_lighting_90_1_2004,106 +dormitory_living_quarters,level_3_lighting_90_1_2004,107 +museum_exhibit_area,level_3_lighting_90_1_2004,108 +museum_restoration,level_3_lighting_90_1_2004,109 +banking_activity,level_3_lighting_90_1_2004,110 +worship_pulpit_choir_area,level_3_lighting_90_1_2004,111 +fellowship_hall_religious_facility,level_3_lighting_90_1_2004,112 +sales,level_3_lighting_90_1_2004,113 +retail_mall_concourse,level_3_lighting_90_1_2004,114 +sports_arena_ring_sports_area,level_3_lighting_90_1_2004,115 +sports_arena_court_sports_area,level_3_lighting_90_1_2004,116 +sports_arena_indoor_playing_field,level_3_lighting_90_1_2004,117 +warehouse_bulk_storage,level_3_lighting_90_1_2004,119 +parking_area_interior,level_3_lighting_90_1_2004,120 +airport_concourse,level_3_lighting_90_1_2004,121 +baggage_carousel,level_3_lighting_90_1_2004,122 +transportation_ticket_counter,level_3_lighting_90_1_2004,123 +sales_display_type_1,level_3_lighting_90_1_2004,124 +sales_display_type_2,level_3_lighting_90_1_2004,124 +sales_display_type_3,level_3_lighting_90_1_2004,125 +sales_display_type_4,level_3_lighting_90_1_2004,125 +bam_automotive_facility,level_3_lighting_90_1_2019,1 +bam_convention_center,level_3_lighting_90_1_2019,2 +bam_courthouse,level_3_lighting_90_1_2019,3 +bam_dinin_bar_lounge_leisure,level_3_lighting_90_1_2019,4 +bam_dining_cafeteria_fast_food,level_3_lighting_90_1_2019,5 +bam_dining_family,level_3_lighting_90_1_2019,6 +bam_dormitory,level_3_lighting_90_1_2019,7 +bam_exercise_center,level_3_lighting_90_1_2019,8 +bam_fire_station,level_3_lighting_90_1_2019,9 +bam_gymnasium,level_3_lighting_90_1_2019,10 +bam_healthcare_clinic,level_3_lighting_90_1_2019,11 +bam_hospital,level_3_lighting_90_1_2019,12 +bam_hotel,level_3_lighting_90_1_2019,13 +bam_library,level_3_lighting_90_1_2019,14 +bam_manufacturing_facility,level_3_lighting_90_1_2019,15 +bam_motel,level_3_lighting_90_1_2019,13 +bam_motion_picture_theater,level_3_lighting_90_1_2019,16 +bam_multifamily,level_3_lighting_90_1_2019,17 +bam_museum,level_3_lighting_90_1_2019,18 +bam_office,level_3_lighting_90_1_2019,19 +bam_parking_garage,level_3_lighting_90_1_2019,20 +bam_penitentiary,level_3_lighting_90_1_2019,21 +bam_performing_arts_theater,level_3_lighting_90_1_2019,22 +bam_police_station,level_3_lighting_90_1_2019,23 +bam_post_office,level_3_lighting_90_1_2019,24 +bam_religious_facility,level_3_lighting_90_1_2019,25 +bam_retail,level_3_lighting_90_1_2019,26 +bam_school_university,level_3_lighting_90_1_2019,27 +bam_sports_arena,level_3_lighting_90_1_2019,28 +bam_town_hall,level_3_lighting_90_1_2019,29 +bam_transportation,level_3_lighting_90_1_2019,30 +bam_warehouse,level_3_lighting_90_1_2019,31 +bam_workshop,level_3_lighting_90_1_2019,32 +office_enclosed_small,level_3_lighting_90_1_2019,79 +office_enclosed_large,level_3_lighting_90_1_2019,80 +office_open,level_3_lighting_90_1_2019,81 +conference_meeting_multipurpose,level_3_lighting_90_1_2019,48 +classroom_lecture_training_general,level_3_lighting_90_1_2019,47 +classroom_lecture_training_penitentiary,level_3_lighting_90_1_2019,46 +lobby_general,level_3_lighting_90_1_2019,75 +lobby_hotel,level_3_lighting_90_1_2019,72 +lobby_performing_arts_theater,level_3_lighting_90_1_2019,74 +lobby_motion_picture_theater,level_3_lighting_90_1_2019,73 +lobby_visually_impaired,level_3_lighting_90_1_2019,70 +lobby_elevator,level_3_lighting_90_1_2019,71 +audience_seating_general,level_3_lighting_90_1_2019,43 +audience_seating_gymnasium,level_3_lighting_90_1_2019,37 +audience_seating_exercise_center,level_3_lighting_90_1_2019,43 +audience_seating_convention_center,level_3_lighting_90_1_2019,43 +audience_seating_penitentiary,level_3_lighting_90_1_2019,39 +audience_seating_religious_facility,level_3_lighting_90_1_2019,41 +audience_seating_sports_arena,level_3_lighting_90_1_2019,42 +audience_seating_performing_arts_theater,level_3_lighting_90_1_2019,40 +audience_seating_motion_picture_theater,level_3_lighting_90_1_2019,38 +audience_seating_transportation,level_3_lighting_90_1_2019,43 +audience_seating_auditorium,level_3_lighting_90_1_2019,36 +atrium_low,level_3_lighting_90_1_2019,33 +atrium_medium,level_3_lighting_90_1_2019,34 +atrium_high,level_3_lighting_90_1_2019,35 +lounge_breakroom_general,level_3_lighting_90_1_2019,78 +lounge_breakroom_healthcare_facility,level_3_lighting_90_1_2019,77 +dining_general,level_3_lighting_90_1_2019,61 +dining_penitentiary,level_3_lighting_90_1_2019,56 +dining_hotel,level_3_lighting_90_1_2019,61 +dining_motel,level_3_lighting_90_1_2019,61 +dining_bar_lounge_leisure,level_3_lighting_90_1_2019,58 +dining_family,level_3_lighting_90_1_2019,60 +dining_cafeteria_fast_food,level_3_lighting_90_1_2019,59 +dining_visually_impaired,level_3_lighting_90_1_2019,57 +kitchen,level_3_lighting_90_1_2019,64 +laboratory_classroom,level_3_lighting_90_1_2019,66 +laboratory_all_other,level_3_lighting_90_1_2019,67 +restroom_visually_impaired,level_3_lighting_90_1_2019,84 +restroom_all_other,level_3_lighting_90_1_2019,85 +performing_arts_dressing_room,level_3_lighting_90_1_2019,120 +corridor_general,level_3_lighting_90_1_2019,53 +corridor_hospital,level_3_lighting_90_1_2019,52 +corridor_manufacturing_facility,level_3_lighting_90_1_2019,53 +corridor_visually_impaired,level_3_lighting_90_1_2019,51 +stairway,level_3_lighting_90_1_2019,88 +stairwell,level_3_lighting_90_1_2019,89 +storage_ all_other_small,level_3_lighting_90_1_2019,90 +storage_ all_other_large,level_3_lighting_90_1_2019,91 +storage_hospital_small,level_3_lighting_90_1_2019,90 +storage_hospital_large,level_3_lighting_90_1_2019,91 +electrical_mechanical,level_3_lighting_90_1_2019,62 +workshop,level_3_lighting_90_1_2019,93 +gymnasium_playing_area,level_3_lighting_90_1_2019,101 +gymnasium_exercise_area,level_3_lighting_90_1_2019,100 +courtroom,level_3_lighting_90_1_2019,54 +confinement_cells,level_3_lighting_90_1_2019,49 +emergency_vehicle_garage,level_3_lighting_90_1_2019,63 +firestation_sleeping_quarters,level_3_lighting_90_1_2019,99 +post_office_sorting_area,level_3_lighting_90_1_2019,121 +exhibit_convention_center,level_3_lighting_90_1_2019,97 +library_stacks,level_3_lighting_90_1_2019,112 +library_reading,level_3_lighting_90_1_2019,111 +recovery,level_3_lighting_90_1_2019,110 +nurses_station,level_3_lighting_90_1_2019,106 +exam_treatment,level_3_lighting_90_1_2019,102 +pharmacy,level_3_lighting_90_1_2019,83 +patient_room,level_3_lighting_90_1_2019,108 +operating_room,level_3_lighting_90_1_2019,107 +nursery,level_3_lighting_90_1_2019,105 +medical_supply,level_3_lighting_90_1_2019,104 +physical_therapy,level_3_lighting_90_1_2019,109 +imaging,level_3_lighting_90_1_2019,103 +laundry_washing,level_3_lighting_90_1_2019,68 +automotive,level_3_lighting_90_1_2019,96 +manufacturing_low_bay,level_3_lighting_90_1_2019,117 +manufacturing_high_bay,level_3_lighting_90_1_2019,116 +detailed_manufacuring,level_3_lighting_90_1_2019,113 +manufacturing_equipment_room,level_3_lighting_90_1_2019,114 +manufacturing_extra_high_bay,level_3_lighting_90_1_2019,115 +guest_room,level_3_lighting_90_1_2019,65 +dormitory_living_quarters,level_3_lighting_90_1_2019,98 +museum_exhibit_area,level_3_lighting_90_1_2019,118 +museum_restoration,level_3_lighting_90_1_2019,119 +banking_activity,level_3_lighting_90_1_2019,44 +worship_pulpit_choir_area,level_3_lighting_90_1_2019,123 +fellowship_hall_religious_facility,level_3_lighting_90_1_2019,122 +sales,level_3_lighting_90_1_2019,86 +retail_mall_concourse,level_3_lighting_90_1_2019,125 +retail_dressing_room,level_3_lighting_90_1_2019,124 +sports_arena_playing_area_class_I,level_3_lighting_90_1_2019,126 +sports_arena_playing_area_class_II,level_3_lighting_90_1_2019,127 +sports_arena_playing_area_class_III,level_3_lighting_90_1_2019,128 +sports_arena_playing_area_class_IV,level_3_lighting_90_1_2019,129 +warehouse_fine_storage,level_3_lighting_90_1_2019,134 +warehouse_bulk_storage,level_3_lighting_90_1_2019,133 +parking_area_interior,level_3_lighting_90_1_2019,82 +airport_concourse,level_3_lighting_90_1_2019,131 +baggage_carousel,level_3_lighting_90_1_2019,130 +transportation_ticket_counter,level_3_lighting_90_1_2019,132 +sales_display_type_1,level_3_lighting_90_1_2019,135 +sales_display_type_2,level_3_lighting_90_1_2019,136 +sales_display_type_3,level_3_lighting_90_1_2019,137 +sales_display_type_4,level_3_lighting_90_1_2019,138 +breakroom,level_3_lighting_90_1_2019,45 +copy_print,level_3_lighting_90_1_2019,50 +computer_room,level_3_lighting_90_1_2019,55 +loading_dock,level_3_lighting_90_1_2019,69 +locker_room,level_3_lighting_90_1_2019,76 +seating_area_general,level_3_lighting_90_1_2019,87 +vehicular_maintenance,level_3_lighting_90_1_2019,92 +chapel_visually_impaired,level_3_lighting_90_1_2019,94 +recreation_common_living_visually_impaired,level_3_lighting_90_1_2019,95 diff --git a/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.csv b/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.csv new file mode 100644 index 0000000000..9b99cdb8fb --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.csv @@ -0,0 +1,174 @@ +ventilation_space_type_name,level_3_ventilation_definition_table,level_3_ventilation_defintion_id +correctional_facilities_cell,level_3_ventilation_90_1_2019,13 +correctional_facilities_dayroom,level_3_ventilation_90_1_2019,14 +correctional_facilities_guard_stations,level_3_ventilation_90_1_2019,15 +correctional_facilities_booking_waiting,level_3_ventilation_90_1_2019,12 +educational_facilities_daycare,level_3_ventilation_90_1_2019,21 +educational_facilities_classroom_young,level_3_ventilation_90_1_2019,17 +educational_facilities_classroom_old,level_3_ventilation_90_1_2019,18 +educational_facilities_lecture_classroom,level_3_ventilation_90_1_2019,22 +educational_facilities_lecture_hall,level_3_ventilation_90_1_2019,23 +educational_facilities_art_classroom,level_3_ventilation_90_1_2019,16 +educational_facilities_science_laboratories,level_3_ventilation_90_1_2019,28 +educational_facilities_wood_metal_shop,level_3_ventilation_90_1_2019,30 +educational_facilities_computer_lab,level_3_ventilation_90_1_2019,19 +educational_facilities_media_center,level_3_ventilation_90_1_2019,25 +educational_facilities_music_theater_dance,level_3_ventilation_90_1_2019,27 +educational_facilities_multiuse_assembly,level_3_ventilation_90_1_2019,26 +educational_facilities_daycare_sickroom,level_3_ventilation_90_1_2019,20 +educational_facilities_libraries,level_3_ventilation_90_1_2019,24 +educational_facilities_university_college_laboratories,level_3_ventilation_90_1_2019,29 +food_beverage_service_restaurant_dining_rooms,level_3_ventilation_90_1_2019,34 +food_beverage_service_cafeteria_fast_food_dining,level_3_ventilation_90_1_2019,32 +food_beverage_service_bars_cocktail_lounges,level_3_ventilation_90_1_2019,31 +food_beverage_service_kitchen,level_3_ventilation_90_1_2019,33 +general_conference_meeting,level_3_ventilation_90_1_2019,37 +general_conference_corridors,level_3_ventilation_90_1_2019,38 +general_conference_storage_rooms,level_3_ventilation_90_1_2019,39 +general_break_rooms,level_3_ventilation_90_1_2019,35 +general_coffee_stations,level_3_ventilation_90_1_2019,36 +hotels_motels_resorts_dormitories_bedroom_living_room,level_3_ventilation_90_1_2019,41 +hotels_motels_resorts_dormitories_barracks_sleeping_areas,level_3_ventilation_90_1_2019,40 +hotels_motels_resorts_dormitories_lobbies_prefunction,level_3_ventilation_90_1_2019,44 +hotels_motels_resorts_dormitories_multi_purpose_assembly,level_3_ventilation_90_1_2019,45 +hotels_motels_resorts_dormitories_laundry_rooms,level_3_ventilation_90_1_2019,42 +hotels_motels_resorts_dormitories_laundry_rooms_w_dwelling_units,level_3_ventilation_90_1_2019,43 +office_buildings_office_space,level_3_ventilation_90_1_2019,62 +office_buildings_reception_areas,level_3_ventilation_90_1_2019,63 +office_buildings_telephone_data_entry,level_3_ventilation_90_1_2019,64 +office_buildings_main_entry_lobbies,level_3_ventilation_90_1_2019,60 +office_buildings_breakrooms,level_3_ventilation_90_1_2019,59 +office_buildings_occupiable_storage_rooms,level_3_ventilation_90_1_2019,61 +miscellaneous_spaces_bank_ vaults_safe_deposit,level_3_ventilation_90_1_2019,47 +miscellaneous_spaces_computer,level_3_ventilation_90_1_2019,48 +miscellaneous_spaces_pharmacy,level_3_ventilation_90_1_2019,52 +miscellaneous_spaces_photo_studios,level_3_ventilation_90_1_2019,53 +miscellaneous_spaces_shipping_receiving,level_3_ventilation_90_1_2019,54 +miscellaneous_spaces_transportation_waiting,level_3_ventilation_90_1_2019,57 +miscellaneous_spaces_warehouses,level_3_ventilation_90_1_2019,58 +miscellaneous_spaces_banks_bank_lobbies,level_3_ventilation_90_1_2019,46 +miscellaneous_spaces_freezer_refrigerated_spaces,level_3_ventilation_90_1_2019,49 +miscellaneous_spaces_manufacturing_wo_hazardous_materials,level_3_ventilation_90_1_2019,50 +miscellaneous_spaces_manufacturing_w_hazardous_materials,level_3_ventilation_90_1_2019,51 +miscellaneous_spaces_sorting_packing_light_assembly,level_3_ventilation_90_1_2019,55 +miscellaneous_spaces_telephone_closets,level_3_ventilation_90_1_2019,56 +public_assembly_spaces_auditorium_seating_area,level_3_ventilation_90_1_2019,83 +public_assembly_spaces_religious_workshop,level_3_ventilation_90_1_2019,90 +public_assembly_spaces_courtrooms,level_3_ventilation_90_1_2019,84 +public_assembly_spaces_legislative_chambers,level_3_ventilation_90_1_2019,85 +public_assembly_spaces_libraries,level_3_ventilation_90_1_2019,86 +public_assembly_spaces_lobbies,level_3_ventilation_90_1_2019,87 +public_assembly_spaces_children_museums,level_3_ventilation_90_1_2019,88 +public_assembly_spaces_museums_galleries,level_3_ventilation_90_1_2019,89 +retail_sales,level_3_ventilation_90_1_2019,91 +retail_mall_common_areas,level_3_ventilation_90_1_2019,95 +retail_barbershop,level_3_ventilation_90_1_2019,92 +retail_beauty_nail_salons,level_3_ventilation_90_1_2019,93 +retail_pet_shops,level_3_ventilation_90_1_2019,96 +retail_supermarket,level_3_ventilation_90_1_2019,97 +retail_coin_operated_laundries,level_3_ventilation_90_1_2019,94 +sports_entertainment_sports_arena,level_3_ventilation_90_1_2019,102 +sports_entertainment_gym_stadium,level_3_ventilation_90_1_2019,102 +sports_entertainment_spectator_areas,level_3_ventilation_90_1_2019,105 +sports_entertainment_swimming,level_3_ventilation_90_1_2019,107 +sports_entertainment_disco_dance_floors,level_3_ventilation_90_1_2019,99 +sports_entertainment_health_club_aerobics_room,level_3_ventilation_90_1_2019,103 +sports_entertainment_health_club_weight_rooms,level_3_ventilation_90_1_2019,104 +sports_entertainment_bowling_alley,level_3_ventilation_90_1_2019,98 +sports_entertainment_gambling_casinos,level_3_ventilation_90_1_2019,100 +sports_entertainment_game_arcades,level_3_ventilation_90_1_2019,101 +sports_entertainment_stages_studios,level_3_ventilation_90_1_2019,106 +animal_facilities_animal_exam_room,level_3_ventilation_90_1_2019,1 +animal_facilities_animal_imaging,level_3_ventilation_90_1_2019,2 +animal_facilities_animal_operating_rooms,level_3_ventilation_90_1_2019,3 +animal_facilities_animal_postoperative_recovery_room,level_3_ventilation_90_1_2019,4 +animal_facilities_animal_preparation_rooms,level_3_ventilation_90_1_2019,5 +animal_facilities_animal_procedure_room,level_3_ventilation_90_1_2019,6 +animal_facilities_animal_surgery_scrub,level_3_ventilation_90_1_2019,7 +animal_facilities_large_animal_holding_room,level_3_ventilation_90_1_2019,8 +animal_facilities_necropsy,level_3_ventilation_90_1_2019,9 +animal_facilities_small_animal_cage_room_static,level_3_ventilation_90_1_2019,10 +animal_facilities_small_animal_cage_room_ventilated,level_3_ventilation_90_1_2019,11 +outpatient_health_care_facilities_birthing_room,level_3_ventilation_90_1_2019,65 +outpatient_health_care_facilities_class_1_imaging_rooms,level_3_ventilation_90_1_2019,66 +outpatient_health_care_facilities_dental_operatory,level_3_ventilation_90_1_2019,67 +outpatient_health_care_facilities_general_examination_room,level_3_ventilation_90_1_2019,68 +outpatient_health_care_facilities_other_dental_treatment_areas,level_3_ventilation_90_1_2019,69 +outpatient_health_care_facilities_physical_therapy_exercise_area,level_3_ventilation_90_1_2019,70 +outpatient_health_care_facilities_physical_therapy_individual_room,level_3_ventilation_90_1_2019,71 +outpatient_health_care_facilities_physical_therapeutic_pool_area,level_3_ventilation_90_1_2019,72 +outpatient_health_care_facilities_prosthetics_orthotics_room,level_3_ventilation_90_1_2019,73 +outpatient_health_care_facilities_psychiatric_consultation_room,level_3_ventilation_90_1_2019,74 +outpatient_health_care_facilities_psychiatric_examination_room,level_3_ventilation_90_1_2019,75 +outpatient_health_care_facilities_psychiatric_group_room,level_3_ventilation_90_1_2019,76 +outpatient_health_care_facilities_psychiatric_seclusion_room,level_3_ventilation_90_1_2019,77 +outpatient_health_care_facilities_speech_therapy_room,level_3_ventilation_90_1_2019,78 +outpatient_health_care_facilities_urgent_care_examination_room,level_3_ventilation_90_1_2019,79 +outpatient_health_care_facilities_urgent_care_observation_room,level_3_ventilation_90_1_2019,80 +outpatient_health_care_facilities_urgent_care_treatment_room,level_3_ventilation_90_1_2019,81 +outpatient_health_care_facilities_urgent_care_triage_room,level_3_ventilation_90_1_2019,82 +transient_residential_common_corridors,level_3_ventilation_90_1_2019,108 +transient_residential_dwelling_unit,level_3_ventilation_90_1_2019,109 +correctional_facilities_cell,level_3_ventilation_90_1_2004,1 +correctional_facilities_dayroom,level_3_ventilation_90_1_2004,2 +correctional_facilities_guard_stations,level_3_ventilation_90_1_2004,3 +correctional_facilities_booking_waiting,level_3_ventilation_90_1_2004,4 +educational_facilities_daycare,level_3_ventilation_90_1_2004,5 +educational_facilities_classroom_young,level_3_ventilation_90_1_2004,6 +educational_facilities_classroom_old,level_3_ventilation_90_1_2004,7 +educational_facilities_lecture_classroom,level_3_ventilation_90_1_2004,8 +educational_facilities_lecture_hall,level_3_ventilation_90_1_2004,9 +educational_facilities_art_classroom,level_3_ventilation_90_1_2004,10 +educational_facilities_science_laboratories,level_3_ventilation_90_1_2004,11 +educational_facilities_wood_metal_shop,level_3_ventilation_90_1_2004,12 +educational_facilities_computer_lab,level_3_ventilation_90_1_2004,13 +educational_facilities_media_center,level_3_ventilation_90_1_2004,14 +educational_facilities_music_theater_dance,level_3_ventilation_90_1_2004,15 +educational_facilities_multiuse_assembly,level_3_ventilation_90_1_2004,16 +food_beverage_service_restaurant_dining_rooms,level_3_ventilation_90_1_2004,17 +food_beverage_service_cafeteria_fast_food_dining,level_3_ventilation_90_1_2004,18 +food_beverage_service_bars_cocktail_lounges,level_3_ventilation_90_1_2004,19 +general_conference_meeting,level_3_ventilation_90_1_2004,20 +general_conference_corridors,level_3_ventilation_90_1_2004,21 +general_conference_storage_rooms,level_3_ventilation_90_1_2004,22 +hotels_motels_resorts_dormitories_bedroom_living_room,level_3_ventilation_90_1_2004,23 +hotels_motels_resorts_dormitories_barracks_sleeping_areas,level_3_ventilation_90_1_2004,24 +hotels_motels_resorts_dormitories_lobbies_prefunction,level_3_ventilation_90_1_2004,25 +hotels_motels_resorts_dormitories_multi_purpose_assembly,level_3_ventilation_90_1_2004,26 +office_buildings_office_space,level_3_ventilation_90_1_2004,27 +office_buildings_reception_areas,level_3_ventilation_90_1_2004,28 +office_buildings_telephone_data_entry,level_3_ventilation_90_1_2004,29 +office_buildings_main_entry_lobbies,level_3_ventilation_90_1_2004,30 +miscellaneous_spaces_bank_ vaults_safe_deposit,level_3_ventilation_90_1_2004,31 +miscellaneous_spaces_computer,level_3_ventilation_90_1_2004,32 +miscellaneous_spaces_pharmacy,level_3_ventilation_90_1_2004,33 +miscellaneous_spaces_photo_studios,level_3_ventilation_90_1_2004,34 +miscellaneous_spaces_shipping_receiving,level_3_ventilation_90_1_2004,35 +miscellaneous_spaces_transportation_waiting,level_3_ventilation_90_1_2004,36 +miscellaneous_spaces_warehouses,level_3_ventilation_90_1_2004,37 +public_assembly_spaces_auditorium_seating_area,level_3_ventilation_90_1_2004,38 +public_assembly_spaces_religious_workshop,level_3_ventilation_90_1_2004,39 +public_assembly_spaces_courtrooms,level_3_ventilation_90_1_2004,40 +public_assembly_spaces_legislative_chambers,level_3_ventilation_90_1_2004,41 +public_assembly_spaces_libraries,level_3_ventilation_90_1_2004,42 +public_assembly_spaces_lobbies,level_3_ventilation_90_1_2004,43 +public_assembly_spaces_children_museums,level_3_ventilation_90_1_2004,44 +public_assembly_spaces_museums_galleries,level_3_ventilation_90_1_2004,45 +retail_sales,level_3_ventilation_90_1_2004,46 +retail_mall_common_areas,level_3_ventilation_90_1_2004,47 +retail_barbershop,level_3_ventilation_90_1_2004,48 +retail_beauty_nail_salons,level_3_ventilation_90_1_2004,49 +retail_pet_shops,level_3_ventilation_90_1_2004,50 +retail_supermarket,level_3_ventilation_90_1_2004,51 +retail_coin_operated_laundries,level_3_ventilation_90_1_2004,52 +sports_entertainment_sports_arena,level_3_ventilation_90_1_2004,53 +sports_entertainment_gym_stadium,level_3_ventilation_90_1_2004,54 +sports_entertainment_spectator_areas,level_3_ventilation_90_1_2004,55 +sports_entertainment_swimming,level_3_ventilation_90_1_2004,56 +sports_entertainment_disco_dance_floors,level_3_ventilation_90_1_2004,57 +sports_entertainment_health_club_aerobics_room,level_3_ventilation_90_1_2004,58 +sports_entertainment_health_club_weight_rooms,level_3_ventilation_90_1_2004,59 +sports_entertainment_bowling_alley,level_3_ventilation_90_1_2004,60 +sports_entertainment_gambling_casinos,level_3_ventilation_90_1_2004,61 +sports_entertainment_game_arcades,level_3_ventilation_90_1_2004,62 +sports_entertainment_stages_studios,level_3_ventilation_90_1_2004,63 diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2004.csv b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2004.csv new file mode 100644 index 0000000000..9cade0dbf9 --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2004.csv @@ -0,0 +1,126 @@ +method,lighting_primary_space_type,lighting_per_area,lighting_secondary_space_type,lighting_per_area_unit,annotation +BA,Automotive Facility,0.9,General,W/ft2, +BA,Convention Center,1.2,General,W/ft2, +BA,Court House,1.2,General,W/ft2, +BA,Dining: Bar Lounge/Leisure,1.3,General,W/ft2, +BA,Dining: Cafeteria/Fast Food,1.4,General,W/ft2, +BA,Dining: Family,1.6,General,W/ft2, +BA,Dormitory,1,General,W/ft2, +BA,Exercise Center,1,General,W/ft2, +BA,Gymnasium,1.1,General,W/ft2, +BA,Health Care-Clinic,1,General,W/ft2, +BA,Hospital,1.2,General,W/ft2, +BA,Hotel,1,General,W/ft2, +BA,Library,1.3,General,W/ft2, +BA,Manufacturing Facility,1.3,General,W/ft2, +BA,Motel,1,General,W/ft2, +BA,Motion Picture Theater,1.2,General,W/ft2, +BA,Multi-Family,0.7,General,W/ft2, +BA,Museum,1.1,General,W/ft2, +BA,Office,1,General,W/ft2, +BA,Parking Garage,0.3,General,W/ft2, +BA,Penitentiary,1,General,W/ft2, +BA,Performing Arts Theater,1.6,General,W/ft2, +BA,Police/Fire Station,1,General,W/ft2, +BA,Post Office,1.1,General,W/ft2, +BA,Religious Building,1.3,General,W/ft2, +BA,Retail,1.5,General,W/ft2, +BA,School/University,1.2,General,W/ft2, +BA,Sports Arena,1.1,General,W/ft2, +BA,Town Hall,1.1,General,W/ft2, +BA,Transportation,1,General,W/ft2, +BA,Warehouse,0.8,General,W/ft2, +BA,Workshop,1.4,General,W/ft2, +CS,Office-Enclosed,1.1,General,W/ft2, +CS,Office-Open Plan,1.1,General,W/ft2, +CS,Conference/Meeting/Multipurpose,1.3,General,W/ft2, +CS,Classroom/Lecture/Training,1.4,General,W/ft2, +CS,Classroom/Lecture/Training,1.3,For Penitentiary,W/ft2, +CS,Lobby,1.3,General,W/ft2, +CS,Lobby,1.1,For Hotel,W/ft2, +CS,Lobby,3.3,For Performing Arts Theater,W/ft2, +CS,Lobby,1.1,For Motion Picture Theater,W/ft2, +CS,Audience/Seating Area,0.9,General,W/ft2, +CS,Audience/Seating Area,0.4,For Gymnasium,W/ft2, +CS,Audience/Seating Area,0.3,For Exercise Center,W/ft2, +CS,Audience/Seating Area,0.7,For Convention Center,W/ft2, +CS,Audience/Seating Area,0.7,For Penitentiary,W/ft2, +CS,Audience/Seating Area,1.7,For Religious Buildings,W/ft2, +CS,Audience/Seating Area,0.4,For Sports Arena,W/ft2, +CS,Audience/Seating Area,2.6,For Performing Arts Theater,W/ft2, +CS,Audience/Seating Area,1.2,For Motion Picture Theater,W/ft2, +CS,Audience/Seating Area,0.5,For Transportation,W/ft2, +CS,Atrium: First Three Floors,0.6,General,W/ft2, +CS,Atrium: Each Additional Floor,0.2,General,W/ft2, +CS,Lounge/Recreation,1.2,General,W/ft2, +CS,Lounge/Recreation,0.8,For Hospital,W/ft2, +CS,Dining Area,0.9,General,W/ft2, +CS,Dining Area,1.3,For Penitentiary,W/ft2, +CS,Dining Area,1.3,For Hotel,W/ft2, +CS,Dining Area,1.2,For Motel,W/ft2, +CS,Dining Area,1.4,For Bar Lounge/Leisure Dining,W/ft2, +CS,Dining Area,2.1,For Family Dining,W/ft2, +CS,Food Preparation,1.2,General,W/ft2, +CS,Laboratory,1.4,General,W/ft2, +CS,Restrooms,0.9,General,W/ft2, +CS,Dressing/Locker/Fitting Room,0.6,General,W/ft2, +CS,Corridor/Transition,0.5,General,W/ft2, +CS,Corridor/Transition,1,For Hospital,W/ft2, +CS,Corridor/Transition,0.5,For Manufacturing Facility,W/ft2, +CS,Stairs: Active,0.6,General,W/ft2, +CS,Active Storage,0.8,General,W/ft2, +CS,Active Storage,0.9,For Hospital,W/ft2, +CS,Inactive Storage,0.3,General,W/ft2, +CS,Inactive Storage,0.8,For Museum,W/ft2, +CS,Electrical/Mechanical,1.5,General,W/ft2, +CS,Workshop,1.9,General,W/ft2, +SS,Gymnasium/Exercise Center,1.4,Playing Area,W/ft2, +SS,Gymnasium/Exercise Center,0.9,Exercise Area,W/ft2, +SS,Courthouse/Police Station/Penitentiary,1.9,Courtroom,W/ft2, +SS,Courthouse/Police Station/Penitentiary,0.9,Confinement Cells,W/ft2, +SS,Courthouse/Police Station/Penitentiary,1.3,Judges Chambers,W/ft2, +SS,Fire Stations,0.8,Fire Station Engine Room,W/ft2, +SS,Fire Stations,0.3,Sleeping Quarters,W/ft2, +SS,Post Office: Sorting Area,1.2,General,W/ft2, +SS,Convention Center: Exhibit Space,1.3,General,W/ft2, +SS,Library,1.1,Card File and Cataloging,W/ft2, +SS,Library,1.7,Stacks,W/ft2, +SS,Library,1.2,Reading Area,W/ft2, +SS,Hospital,2.7,Emergency,W/ft2, +SS,Hospital,0.8,Recovery,W/ft2, +SS,Hospital,1,Nurse Station,W/ft2, +SS,Hospital,1.5,Exam/Treatment,W/ft2, +SS,Hospital,1.2,Pharmacy,W/ft2, +SS,Hospital,0.7,Patient Room,W/ft2, +SS,Hospital,2.2,Operating Room,W/ft2, +SS,Hospital,0.6,Nursery,W/ft2, +SS,Hospital,1.4,Medical Supply,W/ft2, +SS,Hospital,0.9,Physical Therapy,W/ft2, +SS,Hospital,0.4,Radiology,W/ft2, +SS,Hospital,0.6,Laundry: Washing,W/ft2, +SS,Automotive: Service/Repair,0.7,General,W/ft2, +SS,Manufacturing,1.2,Low Bay (<25 ft Floor to Ceiling Height),W/ft2, +SS,Manufacturing,1.7,High Bay (>25 ft Floor to Ceiling Height),W/ft2, +SS,Manufacturing,2.1,Detailed Manufacturing,W/ft2, +SS,Manufacturing,1.2,Equipment Room,W/ft2, +SS,Manufacturing,0.5,Control Room,W/ft2, +SS,Hotel/Motel Guest Rooms,1.1,General,W/ft2, +SS,Dormitory: Living Quarters,1.1,General,W/ft2, +SS,Museum,1,General Exhibition,W/ft2, +SS,Museum,1.7,Restoration,W/ft2, +SS,Bank/Office: Banking Activity Area,1.5,General,W/ft2, +SS,Religious Buildings,2.4,"Worship Pulpit, Choir",W/ft2, +SS,Religious Buildings,0.9,Fellowship Hall,W/ft2, +SS,Retail,1.7,Sales Area,W/ft2, +SS,Retail,1.7,Mall Concourse,W/ft2, +SS,Sports Arena,2.7,Ring Sports Area,W/ft2, +SS,Sports Arena,2.3,Court Sports Area,W/ft2, +SS,Sports Arena,1.4,Indoor Playing Field Area,W/ft2, +SS,Warehouse,1.4,Fine Material Storage,W/ft2, +SS,Warehouse,0.9,Medium/Bulky Material Storage,W/ft2, +SS,Parking Garage: Garage Area,0.2,General,W/ft2, +SS,Transportation,0.6,Airport: Concourse,W/ft2, +SS,Transportation,1,Air/Train/Bus: Baggage Area,W/ft2, +SS,Transportation,1.5,Terminal: Ticket Counter,W/ft2, +SS,Retail,1.6,Sales Additional (Specific Display),W/ft2, +SS,Retail,3.9,Sales Additional (Valuable Merchandise),W/ft2, diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2019.csv b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2019.csv new file mode 100644 index 0000000000..a2f8971a4a --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2019.csv @@ -0,0 +1,139 @@ +method,lighting_primary_space_type,lighting_per_area,lighting_secondary_space_type,lighting_per_area_unit,annotation +BA,Automotive facility,0.75,General,W/ft2, +BA,Convention center,0.64,General,W/ft2, +BA,Courthouse,0.79,General,W/ft2, +BA,Dining: Bar lounge/leisure,0.8,General,W/ft2, +BA,Dining: Cafeteria/fast food,0.76,General,W/ft2, +BA,Dining: Family,0.71,General,W/ft2, +BA,Dormitory,0.53,General,W/ft2, +BA,Exercise center,0.72,General,W/ft2, +BA,Fire station,0.56,General,W/ft2, +BA,Gymnasium,0.76,General,W/ft2, +BA,Health-care clinic,0.81,General,W/ft2, +BA,Hospital,0.96,General,W/ft2, +BA,Hotel/motel,0.56,General,W/ft2, +BA,Library,0.83,General,W/ft2, +BA,Manufacturing facility,0.82,General,W/ft2, +BA,Motion picture theater,0.44,General,W/ft2, +BA,Multifamily,0.45,General,W/ft2, +BA,Museum,0.55,General,W/ft2, +BA,Office,0.64,General,W/ft2, +BA,Parking garage,0.18,General,W/ft2, +BA,Penitentiary,0.69,General,W/ft2, +BA,Performing arts theater,0.84,General,W/ft2, +BA,Police station,0.66,General,W/ft2, +BA,Post office,0.65,General,W/ft2, +BA,Religious facility,0.67,General,W/ft2, +BA,Retail,0.84,General,W/ft2, +BA,School/university,0.72,General,W/ft2, +BA,Sports arena,0.76,General,W/ft2, +BA,Town hall,0.69,General,W/ft2, +BA,Transportation,0.5,General,W/ft2, +BA,Warehouse,0.45,General,W/ft2, +BA,Workshop,0.91,General,W/ft2, +CS,Atrium,0.39,< 20 ft in height,W/ft2, +CS,Atrium,0.48,>= 20 ft and <= 40 ft in height,W/ft2, +CS,Atrium,0.6,> 40 ft in height,W/ft2, +CS,Audience Seating Area,0.61,Auditorium,W/ft2, +CS,Audience Seating Area,0.23,Gymnasium,W/ft2, +CS,Audience Seating Area,0.27,Motion picture theater,W/ft2, +CS,Audience Seating Area,0.67,Penitentiary,W/ft2, +CS,Audience Seating Area,1.16,Performing arts theater,W/ft2, +CS,Audience Seating Area,0.72,Religious facility,W/ft2, +CS,Audience Seating Area,0.33,Sports arena,W/ft2, +CS,Audience Seating Area,0.23,All other audience seating areas,W/ft2, +CS,Banking Activity Area,0.61,General,W/ft2, +CS,Breakroom,0.59,General,W/ft2,(See Lounge/Breakroom) +CS,Classroom/Lecture Hall/Training Room,0.89,Penitentiary,W/ft2, +CS,Classroom/Lecture Hall/Training Room,0.71,All other classrooms/lecture halls/training rooms,W/ft2, +CS,Conference/Meeting/Multipurpose Room,0.97,General,W/ft2, +CS,Confinement Cells,0.7,General,W/ft2, +CS,Copy/Print Room,0.31,General,W/ft2, +CS,Corridor,0.71,Facility for the visually impaired (and not used primarily by the staff),W/ft2, +CS,Corridor,0.71,Hospital,W/ft2, +CS,Corridor,0.41,All other corridors,W/ft2, +CS,Courtroom,1.2,General,W/ft2, +CS,Computer Room,0.94,General,W/ft2, +CS,Dining Area,0.42,Penitentiary,W/ft2, +CS,Dining Area,1.27,Facility for the visually impaired (and not used primarily by staff),W/ft2, +CS,Dining Area,0.86,Bar/lounge or leisure dining,W/ft2, +CS,Dining Area,0.4,Cafeteria or fast food dining,W/ft2, +CS,Dining Area,0.6,Family dining,W/ft2, +CS,Dining Area,0.43,All other dining areas,W/ft2, +CS,Electrical/Mechanical Room,0.43,General,W/ft2, +CS,Emergency Vehicle Garage,0.52,General,W/ft2, +CS,Food Preparation Area,1.09,General,W/ft2, +CS,Guest Room,0.41,General,W/ft2, +CS,Laboratory,1.11,In or as a classroom,W/ft2, +CS,Laboratory,1.33,All other laboratories,W/ft2, +CS,Laundry/Washing Area,0.53,General,W/ft2, +CS,"Loading Dock, Interior",0.88,General,W/ft2, +CS,Lobby,1.69,Facility for the visually impaired (and not used primarily by the staff),W/ft2, +CS,Lobby,0.65,Elevator,W/ft2, +CS,Lobby,0.51,Hotel,W/ft2, +CS,Lobby,0.23,Motion picture theater,W/ft2, +CS,Lobby,1.25,Performing arts theater ,W/ft2, +CS,Lobby,0.84,All other lobbies,W/ft2, +CS,Locker Room,0.52,General,W/ft2, +CS,Lounge/Breakroom,0.42,Healthcare facility,W/ft2, +CS,Lounge/Breakroom,0.59,All other lounges/breakrooms,W/ft2, +CS,Office,0.74,Enclosed and <= 250 ft2,W/ft2, +CS,Office,0.66,Enclosed and > 250 ft2,W/ft2, +CS,Office,0.61,Open plan,W/ft2, +CS,"Parking Area, Interior",0.15,General,W/ft2, +CS,Pharmacy Area,1.66,General,W/ft2, +CS,Restroom,1.26,Facility for the visually impaired (and not used primarily by the staff),W/ft2, +CS,Restroom,0.63,All other restrooms,W/ft2, +CS,Sales Area,1.05,General,W/ft2, +CS,"Seating Area, General",0.23,General,W/ft2, +CS,Stairway,0.49,General,W/ft2,The space containing the stairway shall determine the LPD and control requirements for the stairway. +CS,Stairwell,0.49,General,W/ft2, +CS,Storage Room,0.51,< 50 ft2,W/ft2, +CS,Storage Room,0.38,>= 50 ft2,W/ft2, +CS,Vehicular Maintenance Area,0.6,General,W/ft2, +CS,Workshop,1.26,General,W/ft2, +SS,Facility for the Visually Impaired,0.7,Chapel (used primarily by residents),W/ft2, +SS,Facility for the Visually Impaired,1.77,Recreation room/common living room (and not used primarily by staff),W/ft2, +SS,Automotive,0.6,General,W/ft2,(See 'Vehicular Maintenance Area') +SS,Convention Center: Exhibit Space,0.61,General,W/ft2, +SS,Dormitory: Living Quarters,0.5,General,W/ft2, +SS,Fire Station: Sleeping Quarters,0.23,General,W/ft2, +SS,Gymnasium/Fitness Center,0.9,Exercise area,W/ft2, +SS,Gymnasium/Fitness Center,0.85,Playing area,W/ft2, +SS,Healthcare Facility,1.4,Exam/treatment room,W/ft2, +SS,Healthcare Facility,0.94,Imaging room,W/ft2, +SS,Healthcare Facility,0.62,Medical supply room,W/ft2, +SS,Healthcare Facility,0.92,Nursery,W/ft2, +SS,Healthcare Facility,1.17,Nurse's station,W/ft2, +SS,Healthcare Facility,2.26,Operating room,W/ft2, +SS,Healthcare Facility,0.68,Patient room,W/ft2, +SS,Healthcare Facility,0.91,Physical therapy room,W/ft2, +SS,Healthcare Facility,1.25,Recovery room,W/ft2, +SS,Library,0.96,Reading area,W/ft2, +SS,Library,1.18,Stacks,W/ft2, +SS,Manufacturing Facility,0.8,Detailed manufacturing area,W/ft2, +SS,Manufacturing Facility,0.76,Equipment room,W/ft2, +SS,Manufacturing Facility,1.42,Extra high bay area (> 50 ft floor-to-ceiling height),W/ft2, +SS,Manufacturing Facility,1.24,High bay area (25 to 50 ft floor-to-ceiling height),W/ft2, +SS,Manufacturing Facility,0.86,Low bay area (< 25 ft floor-to-ceiling height),W/ft2, +SS,Museum,0.31,General exhibition area,W/ft2, +SS,Museum,1.1,Restoration room,W/ft2, +SS,Performing Arts Theater: Dressing Room,0.41,General,W/ft2, +SS,Post Office: Sorting Area,0.76,General,W/ft2, +SS,Religious Facility,0.54,Fellowship hall,W/ft2, +SS,Religious Facility,0.85,Worship/pulpit/choir area,W/ft2, +SS,Retail Facilities,0.51,Dressing/fitting room,W/ft2, +SS,Retail Facilities,0.82,Mall concourse,W/ft2, +SS,Sports Arena: Playing Area,2.94,Class I facility,W/ft2, +SS,Sports Arena: Playing Area,2.01,Class II facility,W/ft2, +SS,Sports Arena: Playing Area,1.3,Class III facility,W/ft2, +SS,Sports Arena: Playing Area,0.86,Class IV facility,W/ft2, +SS,Transportation Facility,0.39,Baggage/carousel area,W/ft2, +SS,Transportation Facility,0.25,Airport concourse,W/ft2, +SS,Transportation Facility,0.51,Ticket counter,W/ft2, +SS,Warehouse: Storage Area,0.33,"Medium to bulky, palletized items",W/ft2, +SS,Warehouse: Storage Area,0.69,"Smaller, hand-carried items",W/ft2, +SS,Retail,0.45,Sales Additional (Retail Area 1),W/ft2, +SS,Retail,0.45,Sales Additional (Retail Area 2),W/ft2, +SS,Retail,1.05,Sales Additional (Retail Area 3),W/ft2, +SS,Retail,1.88,Sales Additional (Retail Area 4),W/ft2, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2004.csv b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2004.csv new file mode 100644 index 0000000000..dd3fc692d1 --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2004.csv @@ -0,0 +1,64 @@ +ventilation_primary_space_type,ventilation_secondary_space_type,ventilation_per_person,ventilation_per_person_unit,ventilation_per_area,ventilation_per_area_unit,occupancy_per_area,occupancy_per_area_unit,air_class,os +Correctional Facilities,Cell,5,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2, +Correctional Facilities,Day room,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1, +Correctional Facilities,Guard stations,5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1, +Correctional Facilities,Booking/waiting,7.5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,2, +Educational Facilities,Daycare (through age 4),10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2, +Educational Facilities,Classrooms (ages 5-8),10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1, +Educational Facilities,Classrooms (age 9 plus),10,cfm/person,0.12,cfm/ft2,35,ppl/1000 ft2,1, +Educational Facilities,Lecture classroom,7.5,cfm/person,0.06,cfm/ft2,65,ppl/1000 ft2,1, +Educational Facilities,Lecture hall (fixed seats),7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1, +Educational Facilities,Art classroom,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2, +Educational Facilities,Science laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,, +Educational Facilities,Wood/metal shop,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2, +Educational Facilities,Computer lab,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1, +Educational Facilities,Media center,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1, +Educational Facilities,Music/theater/dance,10,cfm/person,0.06,cfm/ft2,35,ppl/1000 ft2,1, +Educational Facilities,Multi-use assembly,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1, +Food and Beverage Service,Restaurant dining rooms,7.5,cfm/person,0.18,cfm/ft2,70,ppl/1000 ft2,2, +Food and Beverage Service,Cafeteria/fast food dining,7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2, +Food and Beverage Service,"Bars, cocktail lounges",7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2, +General,Conference/meeting,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1, +General,Corridors,,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,1, +General,Storage rooms,,cfm/person,0.12,cfm/ft2,,ppl/1000 ft2,1, +"Hotels, Motels, Resorts, Dormitories",Bedroom/living Room,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1, +"Hotels, Motels, Resorts, Dormitories",Barracks sleeping areas,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1, +"Hotels, Motels, Resorts, Dormitories",Lobbies/prefunction,7.5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1, +"Hotels, Motels, Resorts, Dormitories",Multi-purpose assembly,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1, +Office Buildings,Office space,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1, +Office Buildings,Reception areas,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1, +Office Buildings,Telephone/data entry,5,cfm/person,0.06,cfm/ft2,60,ppl/1000 ft2,1, +Office Buildings,Main entry lobbies,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1, +Miscellaneous Spaces,Bank vaults/safe deposit,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,2, +Miscellaneous Spaces,Computer (not printing),5,cfm/person,0.06,cfm/ft2,4,ppl/1000 ft2,1, +Miscellaneous Spaces,Pharmacy (prep. area),5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2, +Miscellaneous Spaces,Photo studios,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1, +Miscellaneous Spaces,Shipping/receiving,,cfm/person,0.12,cfm/ft2,,ppl/1000 ft2,1, +Miscellaneous Spaces,Transportation waiting,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1, +Miscellaneous Spaces,Warehouses,,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,2, +Public Assembly Spaces,Auditorium seating area,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1, +Public Assembly Spaces,Places of religious workshop,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1, +Public Assembly Spaces,Courtrooms,5,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1, +Public Assembly Spaces,Legislative chambers,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1, +Public Assembly Spaces,Libraries,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1, +Public Assembly Spaces,Lobbies,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1, +Public Assembly Spaces,Museums (children's),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1, +Public Assembly Spaces,Museums/galleries,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1, +Retail,Sales (except as below),7.5,cfm/person,0.12,cfm/ft2,15,ppl/1000 ft2,2, +Retail,Mall common areas,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1, +Retail,Barber shop,7.5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,2, +Retail,Beauty and nail salons,20,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2, +Retail,Pet shops (animal areas),7.5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2, +Retail,Supermarket,7.5,cfm/person,0.06,cfm/ft2,8,ppl/1000 ft2,1, +Retail,Coin-operated laundries,7.5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,2, +Sports and Entertainment,Sports arena (play area),,cfm/person,0.3,cfm/ft2,,ppl/1000 ft2,1, +Sports and Entertainment,"Gym, stadium (play area)",,cfm/person,0.3,cfm/ft2,30,ppl/1000 ft2,2, +Sports and Entertainment,Spectator areas,7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1, +Sports and Entertainment,Swimming (pool & deck),,cfm/person,0.48,cfm/ft2,,ppl/1000 ft2,2, +Sports and Entertainment,Disco/dance floors,20,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1, +Sports and Entertainment,Health club/aerobics room,20,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,2, +Sports and Entertainment,Health club/weight rooms,20,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,2, +Sports and Entertainment,Bowling alley (seating),10,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1, +Sports and Entertainment,Gambling casinos,7.5,cfm/person,0.18,cfm/ft2,120,ppl/1000 ft2,1, +Sports and Entertainment,Game arcades,7.5,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1, +Sports and Entertainment,"Stages, studios",10,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.csv b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.csv new file mode 100644 index 0000000000..424bb9367c --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.csv @@ -0,0 +1,110 @@ +ventilation_primary_space_type,ventilation_secondary_space_type,ventilation_per_person,ventilation_per_person_unit,ventilation_per_area,ventilation_per_area_unit,occupancy_per_area,occupancy_per_area_unit,air_class,os +Animal Facilities,Animal exam room (veterinary office),10,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2, +Animal Facilities,Animal imaging (MRI/CT/PET),10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3, +Animal Facilities,Animal operating rooms,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3, +Animal Facilities,Animal postoperative recovery room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3, +Animal Facilities,Animal preparation rooms,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3, +Animal Facilities,Animal procedure room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3, +Animal Facilities,Animal surgery scrub,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3, +Animal Facilities,Large-animal holding room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3, +Animal Facilities,Necropsy,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3, +Animal Facilities,Small-animal-cage room (static cages),10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3, +Animal Facilities,Small-animal-cage room (ventilated cages),10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3, +Correctional Facilities,Booking/waiting,7.5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,2, +Correctional Facilities,Cell,5,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2, +Correctional Facilities,Dayroom,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1, +Correctional Facilities,Guard stations,5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1, +Educational Facilities,Art classroom,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2, +Educational Facilities,Classrooms (ages 5 to 8),10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1, +Educational Facilities,Classrooms (age 9 plus),10,cfm/person,0.12,cfm/ft2,35,ppl/1000 ft2,1, +Educational Facilities,Computer lab,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1, +Educational Facilities,Daycare sickroom,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,3, +Educational Facilities,Daycare (through age 4),10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2, +Educational Facilities,Lecture classroom,7.5,cfm/person,0.06,cfm/ft2,65,ppl/1000 ft2,1,yes +Educational Facilities,Lecture hall (fixed seats),7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,yes +Educational Facilities,Libraries (education),5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,, +Educational Facilities,Media center,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1, +Educational Facilities,Multiuse assembly,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,yes +Educational Facilities,Music/theater/dance,10,cfm/person,0.06,cfm/ft2,35,ppl/1000 ft2,1,yes +Educational Facilities,Science laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2, +Educational Facilities,University/college laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2, +Educational Facilities,Wood/metal shop,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2, +Food and Beverage Service,"Bars, cocktail lounges",7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2, +Food and Beverage Service,Cafeteria/fast-food dining,7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2, +Food and Beverage Service,Kitchen (cooking),7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2, +Food and Beverage Service,Restaurant dining rooms,7.5,cfm/person,0.18,cfm/ft2,70,ppl/1000 ft2,2, +"Food and Beverage Service, General",Break rooms,5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,1,yes +"Food and Beverage Service, General",Coffee stations,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,yes +"Food and Beverage Service, General",Conference/meeting,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,yes +"Food and Beverage Service, General",Corridors,,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,1,yes +"Food and Beverage Service, General",Occupiable storage rooms for liquids or gels,5,cfm/person,0.12,cfm/ft2,2,ppl/1000 ft2,2, +"Hotels, Motels, Resorts, Dormitories",Barracks sleeping areas,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,yes +"Hotels, Motels, Resorts, Dormitories",Bedroom/living room,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,yes +"Hotels, Motels, Resorts, Dormitories","Laundry rooms, central",5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,2, +"Hotels, Motels, Resorts, Dormitories",Laundry rooms within dwelling units,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1, +"Hotels, Motels, Resorts, Dormitories",Lobbies/prefunction,7.5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,yes +"Hotels, Motels, Resorts, Dormitories",Multipurpose assembly,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,yes +Miscellaneous Spaces,Banks or bank lobbies,7.5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,yes +Miscellaneous Spaces,Bank vaults/safe deposit,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,2,yes +Miscellaneous Spaces,Computer (not printing),5,cfm/person,0.06,cfm/ft2,4,ppl/1000 ft2,1,yes +Miscellaneous Spaces,Freezer and refrigerated spaces (<50�F [10�C]),10,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,2, +Miscellaneous Spaces,Manufacturing where hazardous materials are not used,10,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,2, +Miscellaneous Spaces,Manufacturing where hazardous materials are used (excludes heavy industrial and chemical processes),10,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,3, +Miscellaneous Spaces,Pharmacy (prep. area),5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2, +Miscellaneous Spaces,Photo studios,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1, +Miscellaneous Spaces,Shipping/receiving,10,cfm/person,0.12,cfm/ft2,2,ppl/1000 ft2,2, +Miscellaneous Spaces,"Sorting, packing, light assembly",7.5,cfm/person,0.12,cfm/ft2,7,ppl/1000 ft2,2, +Miscellaneous Spaces,Telephone closets,,cfm/person,0,cfm/ft2,,ppl/1000 ft2,1, +Miscellaneous Spaces,Transportation waiting,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,yes +Miscellaneous Spaces,Warehouses,10,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,2, +Office Buildings,Breakrooms,5,cfm/person,0.12,cfm/ft2,50,ppl/1000 ft2,1, +Office Buildings,Main entry lobbies,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,yes +Office Buildings,Occupiable storage rooms for dry materials,5,cfm/person,0.06,cfm/ft2,2,ppl/1000 ft2,1, +Office Buildings,Office space,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1,yes +Office Buildings,Reception areas,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,yes +Office Buildings,Telephone/data entry,5,cfm/person,0.06,cfm/ft2,60,ppl/1000 ft2,1,yes +Outpatient Health Care Facilities,Birthing room,10,cfm/person,0.18,cfm/ft2,15,ppl/1000 ft2,2, +Outpatient Health Care Facilities,Class 1 imaging rooms,5,cfm/person,0.12,cfm/ft2,5,ppl/1000 ft2,1, +Outpatient Health Care Facilities,Dental operatory,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1, +Outpatient Health Care Facilities,General examination room,7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,1, +Outpatient Health Care Facilities,Other dental treatment areas,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1, +Outpatient Health Care Facilities,Physical therapy exercise area,20,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,2, +Outpatient Health Care Facilities,Physical therapy individual room,10,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1, +Outpatient Health Care Facilities,Physical therapeutic pool area,,cfm/person,0.48,cfm/ft2,,ppl/1000 ft2,2, +Outpatient Health Care Facilities,Prosthetics and orthotics room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1, +Outpatient Health Care Facilities,Psychiatric consultation room,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1, +Outpatient Health Care Facilities,Psychiatric examination room,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1, +Outpatient Health Care Facilities,Psychiatric group room,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1, +Outpatient Health Care Facilities,Psychiatric seclusion room,10,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1, +Outpatient Health Care Facilities,Speech therapy room,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1, +Outpatient Health Care Facilities,Urgent care examination room,7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,1, +Outpatient Health Care Facilities,Urgent care observation room,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1, +Outpatient Health Care Facilities,Urgent care treatment room,7.5,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1, +Outpatient Health Care Facilities,Urgent care triage room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1, +Public Assembly Spaces,Auditorium seating area,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,yes +Public Assembly Spaces,Courtrooms,5,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,yes +Public Assembly Spaces,Legislative chambers,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,yes +Public Assembly Spaces,Libraries (public assembly),5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1, +Public Assembly Spaces,Lobbies,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,yes +Public Assembly Spaces,Museums (children's),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1, +Public Assembly Spaces,Museums/galleries,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,yes +Public Assembly Spaces,Places of religious worship,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,yes +Retail,Sales (except as below),7.5,cfm/person,0.12,cfm/ft2,15,ppl/1000 ft2,2, +Retail,Barbershop,7.5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,2,yes +Retail,Beauty and nail salons,20,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2, +Retail,Coin-operated laundries,7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2, +Retail,Mall common areas,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,yes +Retail,Pet shops (animal areas),7.5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2, +Retail,Supermarket,7.5,cfm/person,0.06,cfm/ft2,8,ppl/1000 ft2,1,yes +Sports and Entertainment,Bowling alley (seating),10,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1, +Sports and Entertainment,Disco/dance floors,20,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,2,yes +Sports and Entertainment,Gambling casinos,7.5,cfm/person,0.18,cfm/ft2,120,ppl/1000 ft2,1, +Sports and Entertainment,Game arcades,7.5,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1, +Sports and Entertainment,"Gym, sports arena (play area)",20,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,2, +Sports and Entertainment,Health club/aerobics room,20,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,2, +Sports and Entertainment,Health club/weight rooms,20,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,2, +Sports and Entertainment,Spectator areas,7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,yes +Sports and Entertainment,"Stages, studios",10,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,yes +Sports and Entertainment,Swimming (pool and deck),,cfm/person,0.48,cfm/ft2,,ppl/1000 ft2,2, +Transient Residential,Common corridors,,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,1,yes +Transient Residential,Dwelling unit,5,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,1,yes diff --git a/data/openstudio_standards_data/database_files/support_constructions.csv b/data/openstudio_standards_data/database_files/support_constructions.csv new file mode 100644 index 0000000000..be2b48475b --- /dev/null +++ b/data/openstudio_standards_data/database_files/support_constructions.csv @@ -0,0 +1,492 @@ +name,intended_surface_type,standard_construction_type,insulation_layer,skylight_framing,material_1,material_2,material_3,material_4,material_5,material_6 +Typical Attic Floor,AtticFloor,WoodFramed,Typical Insulation,,1/2IN Gypsum,Typical Insulation,1/2IN Gypsum,,, +Typical Wood Joist Attic Floor,AtticFloor,WoodFramed,Typical Insulation,,5/8 in. Gypsum Board,Typical Insulation,,,, +Typical Wood Joist Attic Floor Ceiling,AtticFloor,WoodFramed,,,Typical Insulation,5/8 in. Gypsum Board,,,, +Typical Uninsulated Metal Roof Attic Roof,AtticRoof,WoodFramed,,,Roof Membrane,Metal Decking,,,, +Typical Uninsulated Wood Joist Attic Roof,AtticRoof,WoodFramed,,,Asphalt Shingles,5/8 in. Plywood,,,, +Typical Attic Soffit,AtticWall,,,,5/8 in. Plywood,,,,, +Typical Insulated Metal Door,ExteriorDoor,,Typical Insulation,,F08 Metal surface,Typical Insulation,,,, +Typical Overhead Door,ExteriorDoor,RollUp,Typical Insulation,,Typical Insulation,,,,, +Typical Uninsulated Swinging Door,ExteriorDoor,Swinging,Typical Insulation,,Typical Insulation,,,,, +Adiabatic ExteriorFloor,ExteriorFloor,Mass,,,Adiabatic Material,,,,, +Typical Carpeted 4in Slab Floor,ExteriorFloor,,,,MAT-CC05 4 HW CONCRETE,Typical Carpet Pad,,,, +Typical Insulated Carpeted 4in Slab Floor,ExteriorFloor,,Typical Insulation,,Typical Insulation,MAT-CC05 4 HW CONCRETE,Typical Carpet Pad,,, +Typical Insulated Exterior Mass Floor,ExteriorFloor,Mass,Typical Insulation,,Typical Insulation,4 in. Normalweight Concrete Floor,Typical Carpet Pad,,, +Typical Insulated Exterior Mass Floor Ceiling,ExteriorFloor,Mass,Typical Insulation,,Typical Carpet Pad,4 in. Normalweight Concrete Floor,Typical Insulation,,, +Typical Insulated Steel Framed Exterior Floor,ExteriorFloor,SteelFramed,Typical Insulation,,25mm Stucco,5/8 in. Gypsum Board,Typical Insulation,5/8 in. Gypsum Board,Typical Carpet Pad, +Typical Insulated Wood Framed Exterior Floor,ExteriorFloor,WoodFramed,Typical Insulation,,25mm Stucco,5/8 in. Gypsum Board,Typical Insulation,5/8 in. Gypsum Board,Typical Carpet Pad, +Typical Uncarpeted 4in Slab Floor,ExteriorFloor,,,,MAT-CC05 4 HW CONCRETE,,,,, +Adiabatic Roof,ExteriorRoof,Attic and Other,,,Adiabatic Material,,,,, +Metal roofR_R30,ExteriorRoof,,Typical Insulation,,Metal Standing Seam - 1/16 in. CBES,R_R30,,,, +Metal roofR_R38,ExteriorRoof,,Typical Insulation,,Metal Standing Seam - 1/16 in. CBES,R_R38,,,, +Metal roofR_T24_2013_24.86,ExteriorRoof,,Typical Insulation,,Metal Standing Seam - 1/16 in. CBES,R_T24_2013_24.86,,,, +Metal roofR1_R14.20,ExteriorRoof,,Typical Insulation,,Metal Standing Seam - 1/16 in. CBES,R1_R14.20,,,, +Metal roofR2_R12.90,ExteriorRoof,,Typical Insulation,,Metal Standing Seam - 1/16 in. CBES,R2_R12.90,,,, +Metal roofR3_R17.74,ExteriorRoof,,Typical Insulation,,Metal Standing Seam - 1/16 in. CBES,R3_R17.74,,,, +Metal roofR4_R20.28,ExteriorRoof,,Typical Insulation,,Metal Standing Seam - 1/16 in. CBES,R4_R20.28,,,, +Typical Built Up Roof,ExteriorRoof,IEAD,Typical Insulation,,Built-up Roofing,Typical Insulation,Metal Surface,,, +Typical Built Up Roof - Highly Reflective,ExteriorRoof,IEAD,Typical Insulation,,Built-up Roofing - Highly Reflective,Typical Insulation,Metal Surface,,, +Typical IEAD Roof,ExteriorRoof,IEAD,Typical Insulation,,Roof Membrane,Typical Insulation,Metal Roof Surface,,, +Typical IEAD Roof - Highly Reflective,ExteriorRoof,IEAD,Typical Insulation,,Roof Membrane - Highly Reflective,Typical Insulation,Metal Roof Surface,,, +Typical Insulated Metal Building Roof,ExteriorRoof,Metal Building,Typical Insulation,,Metal Roof Surface,Typical Insulation,,,, +Typical Insulated Metal Building Roof - Highly Reflective,ExteriorRoof,Metal Building,Typical Insulation,,Metal Roof Surface - Highly Reflective,Typical Insulation,,,, +Typical Uninsulated Metal Building Roof,ExteriorRoof,Metal Building,,,Metal Roofing,,,,, +Typical Uninsulated Metal Building Roof - Highly Reflective,ExteriorRoof,Metal Building,,,Metal Roofing - Highly Reflective,,,,, +Adiabatic Wall,ExteriorWall,Mass,,,Adiabatic Material,,,,, +Metal framed wallsW_m1_R15,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W_m1_R15,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, +Metal framed wallsW_m2_R19,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W_m2_R19,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, +Metal framed wallsW_m3_R21,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W_m3_R21,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, +Metal framed wallsW_T24_2013_R13.99,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W_T24_2013_R13.99,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, +Metal framed wallsW1_R8.60,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W1_R8.60,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, +Metal framed wallsW2_R11.13,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W2_R11.13,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, +Metal framed wallsW3_R11.36,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W3_R11.36,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, +Metal framed wallsW4_R12.62,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W4_R12.62,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, +Typical Insulated Exterior Mass Wall,ExteriorWall,Mass,Typical Insulation,,1IN Stucco,8IN CONCRETE HW RefBldg,Typical Insulation,1/2IN Gypsum,, +Typical Insulated Metal Building Wall,ExteriorWall,Metal Building,Typical Insulation,,Metal Siding,Typical Insulation,1/2IN Gypsum,,, +Typical Insulated Steel Framed Exterior Wall,ExteriorWall,SteelFramed,Typical Insulation,,25mm Stucco,5/8 in. Gypsum Board,Typical Insulation,5/8 in. Gypsum Board,, +Typical Insulated Wood Framed Exterior Wall,ExteriorWall,WoodFramed,Typical Insulation,,25mm Stucco,5/8 in. Gypsum Board,Typical Insulation,5/8 in. Gypsum Board,, +Typical Uninsulated Exterior Mass Wall,ExteriorWall,Mass,,,1IN Stucco,8IN CONCRETE HW RefBldg,1/2IN Gypsum,,, +Typical Uninsulated Metal Building Wall,ExteriorWall,Metal Building,,,Metal Siding,1/2IN Gypsum,,,, +Typical Uninsulated Steel Framed Exterior Wall,ExteriorWall,SteelFramed,,,Wood Siding,1/2IN Gypsum,,,, +WoodWallU110,ExteriorWall,,,,Plywood - 5/8 in.,Compliance Insulation R6.46,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 3/8 in.,, +ASHRAE 189.1-2009 ExtWindow ClimateZone 1,ExteriorWindow,,,,Theoretical Glass [167],,,,, +ASHRAE 189.1-2009 ExtWindow ClimateZone 2,ExteriorWindow,,,,Theoretical Glass [197],,,,, +ASHRAE 189.1-2009 ExtWindow ClimateZone 3,ExteriorWindow,,,,Theoretical Glass [202],,,,, +ASHRAE 189.1-2009 ExtWindow ClimateZone 4-5,ExteriorWindow,,,,Theoretical Glass [207],,,,, +ASHRAE 189.1-2009 ExtWindow ClimateZone 6,ExteriorWindow,,,,Theoretical Glass [216],,,,, +ASHRAE 189.1-2009 ExtWindow ClimateZone 7-8,ExteriorWindow,,,,Theoretical Glass [221],,,,, +ASHRAE 189.1-2009 ExtWindow ClimateZone alt-res 4-5,ExteriorWindow,,,,Theoretical Glass [216],,,,, +U 0.11 SHGC 0.34 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.11 SHGC 0.34 Simple Glazing,,,,, +U 0.11 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.11 SHGC 0.38 Simple Glazing,,,,, +U 0.12 SHGC 0.34 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.12 SHGC 0.34 Simple Glazing,,,,, +U 0.12 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.12 SHGC 0.38 Simple Glazing,,,,, +U 0.13 SHGC 0.32 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.13 SHGC 0.32 Simple Glazing,,,,, +U 0.13 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.13 SHGC 0.38 Simple Glazing,,,,, +U 0.14 SHGC 0.31 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.14 SHGC 0.31 Simple Glazing,,,,, +U 0.14 SHGC 0.34 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.14 SHGC 0.34 Simple Glazing,,,,, +U 0.14 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.14 SHGC 0.36 Simple Glazing,,,,, +U 0.14 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.14 SHGC 0.38 Simple Glazing,,,,, +U 0.15 SHGC 0.31 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.15 SHGC 0.31 Simple Glazing,,,,, +U 0.15 SHGC 0.34 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.15 SHGC 0.34 Simple Glazing,,,,, +U 0.17 SHGC 0.31 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.17 SHGC 0.31 Simple Glazing,,,,, +U 0.17 SHGC 0.32 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.17 SHGC 0.32 Simple Glazing,,,,, +U 0.17 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.17 SHGC 0.36 Simple Glazing,,,,, +U 0.18 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.18 SHGC 0.22 Simple Glazing,,,,, +U 0.18 SHGC 0.24 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.18 SHGC 0.24 Simple Glazing,,,,, +U 0.19 SHGC 0.20 Trp LoE Film (55) Bronze 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,BRONZE 6MM,AIR 13MM,COATED POLY-55,AIR 13MM,CLEAR 3MM, +U 0.20 SHGC 0.19 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.20 SHGC 0.19 Simple Glazing,,,,, +U 0.20 SHGC 0.20 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.20 SHGC 0.20 Simple Glazing,,,,, +U 0.20 SHGC 0.21 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.20 SHGC 0.21 Simple Glazing,,,,, +U 0.20 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.20 SHGC 0.22 Simple Glazing,,,,, +U 0.23 SHGC 0.31 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.23 SHGC 0.31 Simple Glazing,,,,, +U 0.23 SHGC 0.34 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.23 SHGC 0.34 Simple Glazing,,,,, +U 0.24 SHGC 0.11 Dbl LoE Elec Abs Colored 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,ECABS-2 COLORED 6MM,ARGON 13MM,LoE SPEC SEL CLEAR 6MM Rev,,, +U 0.24 SHGC 0.16 Dbl Elec Abs Colored 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,ECABS-2 COLORED 6MM,ARGON 13MM,CLEAR 6MM,,, +U 0.24 SHGC 0.23 Dbl LoE Spec Sel Tint 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,LoE SPEC SEL TINT 6MM,ARGON 13MM,CLEAR 6MM,,, +U 0.25 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.25 SHGC 0.22 Simple Glazing,,,,, +U 0.25 SHGC 0.24 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.25 SHGC 0.24 Simple Glazing,,,,, +U 0.25 SHGC 0.40 Dbl LoE (e2-.1) Tint 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,LoE TINT 6MM,ARGON 13MM,CLEAR 6MM,,, +U 0.26 SHGC 0.40 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.26 SHGC 0.40 Simple Glazing,,,,, +U 0.29 SHGC 0.11 Dbl LoE Elec Ref Colored 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,ECREF-2 COLORED 6MM,AIR 13MM,LoE SPEC SEL CLEAR 6MM Rev,,, +U 0.29 SHGC 0.17 Dbl Elec Abs Colored 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,ECABS-2 COLORED 6MM,AIR 13MM,CLEAR 6MM,,, +U 0.29 SHGC 0.22 Trp LoE Film (55) Bronze 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,BRONZE 6MM,AIR 6MM,COATED POLY-55,AIR 6MM,CLEAR 3MM, +U 0.29 SHGC 0.40 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.29 SHGC 0.40 Simple Glazing,,,,, +U 0.30 SHGC 0.40 Dbl LoE (e2-.1) Tint 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,LoE TINT 6MM,AIR 13MM,CLEAR 6MM,,, +U 0.32 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.32 SHGC 0.36 Simple Glazing,,,,, +U 0.33 SHGC 0.11 Dbl LoE Elec Ref Colored 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,ECREF-2 COLORED 6MM,AIR 13MM,LoE SPEC SEL CLEAR 6MM Rev,,, +U 0.33 SHGC 0.40 Dbl LoE (e2-.1) Tint 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,LoE TINT 6MM,AIR 13MM,CLEAR 6MM,,, +U 0.33 SHGC 0.45 Trp LoE Film (77) Clr 3mm/6mm Air,ExteriorWindow,Metal framing (all other),,,CLEAR 3MM,AIR 6MM,COATED POLY-77,AIR 6MM,CLEAR 3MM, +U 0.34 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.34 SHGC 0.38 Simple Glazing,,,,, +U 0.34 SHGC 0.40 Dbl LoE (e2-.1) Tint 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,LoE TINT 6MM,AIR 13MM,CLEAR 6MM,,, +U 0.34 SHGC 0.45 Dbl LoE (e2-.2) Clr 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,PYR B CLEAR 6MM,AIR 13MM,CLEAR 6MM,,, +U 0.35 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.35 SHGC 0.22 Simple Glazing,,,,, +U 0.35 SHGC 0.24 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.35 SHGC 0.24 Simple Glazing,,,,, +U 0.35 SHGC 0.26 Dbl Ref-C-M Clr 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,REF C CLEAR MID 6MM,ARGON 13MM,CLEAR 6MM,,, +U 0.35 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,LoE TINT 6MM,AIR 13MM,CLEAR 6MM,,, +U 0.36 SHGC 0.35 Dbl LoE Spec Sel Tint 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,LoE SPEC SEL TINT 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.36 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.36 SHGC 0.36 Simple Glazing,,,,, +U 0.36 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.36 SHGC 0.38 Simple Glazing,,,,, +U 0.38 SHGC 0.26 Dbl Ref B-H Tint 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,REF B TINT HI 6MM,ARGON 13MM,CLEAR 6MM,,, +U 0.38 SHGC 0.30 Dbl Ref-B-H Clr 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,ARGON 13MM,CLEAR 6MM,,, +U 0.39 SHGC 0.32,ExteriorWindow,Metal framing (all other),,,Theoretical Glass 347,,,,, +U 0.39 SHGC 0.38,ExteriorWindow,Metal framing (all other),,,Theoretical Glass 297,,,,, +U 0.40 SHGC 0.43 Dbl LoE Spec Sel Clr 3mm/6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,LoE SPEC SEL CLEAR 3MM,AIR 6MM,CLEAR 6MM,,, +U 0.40 SHGC 0.45,ExteriorWindow,Metal framing (all other),,,ECABS-2 BLEACHED 6MM,AIR 6MM,LoE SPEC SEL CLEAR 6MM Rev,,, +U 0.42 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.42 SHGC 0.25 Simple Glazing,,,,, +U 0.42 SHGC 0.34 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.42 SHGC 0.34 Simple Glazing,,,,, +U 0.42 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,LoE TINT 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.42 SHGC 0.40 Dbl LoE (e2-.1) Tint 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,LoE TINT 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.42 SHGC 0.45 Dbl Ref-D Clr 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,REF D CLEAR 6MM,ARGON 13MM,CLEAR 6MM,,, +U 0.43 SHGC 0.26 Dbl Ref-B-H Clr 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,AIR 13MM,CLEAR 6MM,,, +U 0.43 SHGC 0.29 Dbl LoE Spec Sel Tint 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,LoE SPEC SEL TINT 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.44 SHGC 0.20 Dbl Ref-B-H Tint 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,REF B TINT HI 6MM,AIR 13MM,CLEAR 6MM,,, +U 0.44 SHGC 0.26 Dbl Ref-B-H Clr 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,AIR 13MM,CLEAR 6MM,,, +U 0.45 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.45 SHGC 0.25 Simple Glazing,,,,, +U 0.45 SHGC 0.31 Dbl Ref-B-H Clr 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,AIR 13MM,CLEAR 6MM,,, +U 0.45 SHGC 0.33 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.45 SHGC 0.33 Simple Glazing,,,,, +U 0.46 SHGC 0.45 Dbl Grey 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,GREY 6MM,AIR 13MM,CLEAR 6MM,,, +U 0.47 SHGC 0.33 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.47 SHGC 0.33 Simple Glazing,,,,, +U 0.48 SHGC 0.19 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.48 SHGC 0.19 Simple Glazing,,,,, +U 0.48 SHGC 0.21 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.48 SHGC 0.21 Simple Glazing,,,,, +U 0.48 SHGC 0.20 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.48 SHGC 0.20 Simple Glazing,,,,, +U 0.48 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.48 SHGC 0.22 Simple Glazing,,,,, +U 0.48 SHGC 0.40 Dbl Ref-D Clr 6mm/13mm,ExteriorWindow,Metal framing (all other),,,REF D CLEAR 6MM,AIR 13MM,CLEAR 6MM,,, +U 0.50 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.50 SHGC 0.22 Simple Glazing,,,,, +U 0.50 SHGC 0.23 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.50 SHGC 0.23 Simple Glazing,,,,, +U 0.52 SHGC 0.22 Dbl Ref-B-L Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF B CLEAR LO 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.52 SHGC 0.39 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.52 SHGC 0.39 Simple Glazing,,,,, +U 0.52 SHGC 0.40 Dbl Ref-D Clr 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,REF D CLEAR 6MM,AIR 13MM,CLEAR 6MM,,, +U 0.52 SHGC 0.49 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.52 SHGC 0.49 Simple Glazing,,,,, +U 0.52 SHGC 0.615 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.52 SHGC 0.615 Simple Glazing,,,,, +U 0.54 SHGC 0.13 Dbl Ref-A-L Clr 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,REF A CLEAR LO 6MM,AIR 13MM,CLEAR 6MM,,, +U 0.54 SHGC 0.18 Dbl Ref-A-M Tint 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF A TINT MID 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.54 SHGC 0.23 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.54 SHGC 0.23 Simple Glazing,,,,, +U 0.54 SHGC 0.27 Dbl Ref-C-H Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF C CLEAR HI 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.55 SHGC 0.25,ExteriorWindow,Metal framing (all other),,,Glass_2175_LayerAvg,Gap_1_W_0_0032,Glass_2022F_LayerAvg,,, +U 0.55 SHGC 0.31 Dbl Ref-D Tint 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF D TINT 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.56 SHGC 0.35 Dbl Ref-D Tint 6mm/6mm,ExteriorWindow,Metal framing (all other),,,REF D TINT 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.56 SHGC 0.76 Dbl Clr 3mm/6mm Air,ExteriorWindow,Metal framing (all other),,,CLEAR 3MM,AIR 6MM,CLEAR 3MM,,, +U 0.57 SHGC 0.25 Dbl Ref-C-H Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF C CLEAR HI 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF D CLEAR 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,BLUE 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.59 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.59 SHGC 0.36 Simple Glazing,,,,, +U 0.59 SHGC 0.39 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.59 SHGC 0.39 Simple Glazing,,,,, +U 0.60 SHGC 0.23 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.60 SHGC 0.23 Simple Glazing,,,,, +U 0.62 SHGC 0.20 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.62 SHGC 0.20 Simple Glazing,,,,, +U 0.62 SHGC 0.21 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.62 SHGC 0.21 Simple Glazing,,,,, +U 0.62 SHGC 0.25 Dbl Ref-C-H Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF C CLEAR HI 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.62 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF D CLEAR 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.62 SHGC 0.41 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.62 SHGC 0.41 Simple Glazing,,,,, +U 0.62 SHGC 0.49 Dbl Blue 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,BLUE 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.65 SHGC 0.25 Dbl Ref-C-H Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF C CLEAR HI 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.67 SHGC 0.77 Sgl LoE (e2-.2) Clr 3mm,ExteriorWindow,Metal framing (all other),,,PYR B CLEAR 3MM,,,,, +U 0.71 SHGC 0.25 Dbl Ref-C-H Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF C CLEAR HI 6MM,AIR 6MM,CLEAR 6MM,,, +U 0.72 SHGC 0.25 Sgl Ref-B-M Tint 6mm,ExteriorWindow,Metal framing (all other),,,REF B TINT MID 6MM,,,,, +U 0.72 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.72 SHGC 0.25 Simple Glazing,,,,, +U 0.72 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.72 SHGC 0.36 Simple Glazing,,,,, +U 0.72 SHGC 0.39 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.72 SHGC 0.39 Simple Glazing,,,,, +U 0.75 SHGC 0.72 Sgl LoE (e2-.2) Clr 6mm,ExteriorWindow,Metal framing (all other),,,PYR B CLEAR 6MM,,,,, +U 0.88 SHGC 0.16 Sgl Ref-A-L Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF A CLEAR LO 6MM,,,,, +U 0.88 SHGC 0.27 Sgl Elec Ref Colored 6mm,ExteriorWindow,Metal framing (all other),,,ECREF-1 COLORED 6MM,,,,, +U 0.98 SHGC 0.45 Sgl Ref-B-H Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,,,,, +U 0.98 SHGC 0.68 Sgl Ref-B-H Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,,,,, +U 1.17 SHGC 0.39 Sgl Ref-B-H Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,,,,, +U 1.17 SHGC 0.49 Sgl Ref-D Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF D CLEAR 6MM,,,,, +U 1.17 SHGC 0.68 Sgl Green 3mm,ExteriorWindow,Metal framing (all other),,,GREEN 3MM,,,,, +U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm,ExteriorWindow,Metal framing (all other),,,ECREF-1 COLORED 6MM,,,,, +U 1.22 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 1.22 SHGC 0.25 Simple Glazing,,,,, +U 1.22 SHGC 0.34 Sgl Ref-C-H Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF C CLEAR HI 6MM,,,,, +U 1.22 SHGC 0.39 Sgl Ref-B-H Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,,,,, +U 1.22 SHGC 0.54 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 1.22 SHGC 0.54 Simple Glazing,,,,, +U 1.22 SHGC 0.61 Sgl Green 6mm,ExteriorWindow,Metal framing (all other),,,GREEN 6MM,,,,, +U 1.98 SHGC 0.36 Sgl Ref-B-H Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,,,,, +U 1.98 SHGC 0.61 Sgl Green 6mm,ExteriorWindow,Metal framing (all other),,,GREEN 6MM,,,,, +U0.47_SHGC_0.49_SimpleGlazing_Window_05,ExteriorWindow,,,,U0.47_SHGC_0.49_SimpleGlazing_Window_05,,,,, +U0.47_SHGC0.46_SimpleGlazing_Window_07,ExteriorWindow,,,,U0.47_SHGC0.46_SimpleGlazing_Window_07,,,,, +U0.47_SHGC0.47_SimpleGlazing_Window_06,ExteriorWindow,,,,U0.47_SHGC0.47_SimpleGlazing_Window_06,,,,, +U0.47_SHGC0.47_SimpleGlazing_Window_11,ExteriorWindow,,,,U0.47_SHGC0.47_SimpleGlazing_Window_11,,,,, +U0.47_SHGC0.5_SimpleGlazing_Window_03,ExteriorWindow,,,,U0.47_SHGC0.5_SimpleGlazing_Window_03,,,,, +U0.77_SHGC_0.77_SimpleGlazing_Window_02,ExteriorWindow,,,,U0.77_SHGC_0.77_SimpleGlazing_Window_02,,,,, +U0.77_SHGC0.5_SimpleGlazing_Window_09,ExteriorWindow,,,,U0.77_SHGC0.5_SimpleGlazing_Window_09,,,,, +U0.77_SHGC0.61_SimpleGlazing_Window_08,ExteriorWindow,,,,U0.77_SHGC0.61_SimpleGlazing_Window_08,,,,, +U0.77_SHGC0.62_SimpleGlazing_Window_04,ExteriorWindow,,,,U0.77_SHGC0.62_SimpleGlazing_Window_04,,,,, +U1.23_SHGC0.5_SimpleGlazing_Window_12,ExteriorWindow,,,,U1.23_SHGC0.5_SimpleGlazing_Window_12,,,,, +U1.23_SHGC0.82_SimpleGlazing_Window_01,ExteriorWindow,,,,U1.23_SHGC0.82_SimpleGlazing_Window_01,,,,, +U1.23_SHGC0.82_SimpleGlazing_Window_10,ExteriorWindow,,,,U1.23_SHGC0.82_SimpleGlazing_Window_10,,,,, +Adiabatic GroundContactFloor,GroundContactFloor,Mass,,,Adiabatic Material,,,,, +ext-slab,GroundContactFloor,Mass,,,6 in. Normalweight Concrete Floor,,,,, +ext-slab-mass,GroundContactFloor,Mass,CP02 CARPET PAD,,HW CONCRETE,CP02 CARPET PAD,,,, +ext-slab-metal-building,GroundContactFloor,Metal Building,,,HW CONCRETE 8 in,,,,, +ext-slab-steel-frame,GroundContactFloor,SteelFramed,CP02 CARPET PAD,,HW CONCRETE 8 in,CP02 CARPET PAD,,,, +Ground FloorGround_Floor_R11_T2013,GroundContactFloor,,,,Ground_Floor_R11_T2013,Plywood - 5/8 in. CBES,Carpet - 3/4 in. CBES,,, +Ground FloorGround_Floor_R17_T2013,GroundContactFloor,,,,Ground_Floor_R17_T2013,Plywood - 5/8 in. CBES,Carpet - 3/4 in. CBES,,, +Ground FloorGround_Floor_R22_T2013,GroundContactFloor,,,,Ground_Floor_R22_T2013,Plywood - 5/8 in. CBES,Carpet - 3/4 in. CBES,,, +Smallhotel 2010 Slab Floor,GroundContactFloor,Mass,Typical Insulation,,8 in. Normalweight Concrete Floor,CP02 CARPET PAD,,,, +Typical Carpeted 6in Slab Floor,GroundContactFloor,Mass,,,6 in. Normalweight Concrete Floor,Typical Carpet Pad,,,, +Typical Carpeted 8in Slab Floor,GroundContactFloor,Mass,,,8 in. Normalweight Concrete Floor,Typical Carpet Pad,,,, +Typical Insulated 6in Slab Floor,GroundContactFloor,Mass,Typical Insulation,,Typical Insulation,6 in. Normalweight Concrete Floor,,,, +Typical Insulated 8in Slab Floor,GroundContactFloor,Mass,Typical Insulation,,Typical Insulation,8 in. Normalweight Concrete Floor,,,, +Typical Insulated Carpeted 6in Slab Floor,GroundContactFloor,Mass,Typical Insulation,,Typical Insulation,6 in. Normalweight Concrete Floor,Typical Carpet Pad,,, +Typical Insulated Carpeted 8in Slab Floor,GroundContactFloor,Mass,Typical Insulation,,Typical Insulation,8 in. Normalweight Concrete Floor,Typical Carpet Pad,,, +Typical Uncarpeted 6in Slab Floor,GroundContactFloor,Mass,,,6 in. Normalweight Concrete Floor,,,,, +Typical Uninsulated 6in Slab Floor,GroundContactFloor,Mass,,,6 in. Normalweight Concrete Floor,,,,, +Typical Uninsulated 8in Slab Floor,GroundContactFloor,Mass,,,8 in. Normalweight Concrete Floor,,,,, +Typical Uninsulated Carpeted 8in Slab Floor,GroundContactFloor,Mass,,,8 in. Concrete Block Basement Wall,Typical Carpet Pad,,,, +Typical Unisulated Carpeted 6in Slab Floor,GroundContactFloor,Mass,,,6 in. Normalweight Concrete Floor,Typical Carpet Pad,,,, +Typical Insulated Basement Mass Wall,GroundContactWall,Mass,Typical Insulation,,Typical Insulation,8 in. Concrete Block Basement Wall,,,, +Typical Uninsulated Basement Mass Wall,GroundContactWall,Mass,,,8 in. Concrete Block Basement Wall,,,,, +ceiling_Metal roof,InteriorCeiling,,,,Metal Standing Seam - 1/16 in.,ceiling_2_Insulation,,,, +int_slab_ceiling_smallhotel,InteriorCeiling,,,,CP02 CARPET PAD,4 in. Normalweight Concrete Floor,,,, +LargeHotel Interior Ceiling,InteriorCeiling,,,,CP02 CARPET PAD,100mm Normalweight concrete floor,Nonres_Floor_Insulation,G01 13mm gypsum board,, +NACM_Drop Ceiling,InteriorCeiling,,,,Acoustic Ceiling,,,,, +Plenum Acoustical Tile,InteriorCeiling,,,,Acoustic Tile - 1/2 in.,,,,, +Typical Interior Ceiling,InteriorCeiling,,,,CP02 CARPET PAD,100mm Normalweight concrete floor,,,, +Typical Interior Door,InteriorDoor,,,,G05 25mm wood,,,,, +int_slab_floor_smallhotel,InteriorFloor,,,,4 in. Normalweight Concrete Floor,CP02 CARPET PAD,,,, +LargeHotel Interior Floor,InteriorFloor,,,,G01 13mm gypsum board,Nonres_Floor_Insulation,100mm Normalweight concrete floor,CP02 CARPET PAD,, +NACM_Interior Floor,InteriorFloor,,,,NACM_Carpet 3/4in,,,,, +Typical Interior Floor,InteriorFloor,,,,100mm Normalweight concrete floor,CP02 CARPET PAD,,,, +Typical Interior Slab Floor,InteriorFloor,Mass,,,4 in. Normalweight Concrete Floor,Typical Carpet Pad,,,, +Typical Interior Partition,InteriorPartition,,,,G05 25mm wood,,,,, +Uninsulated Steel Stud Wall,InteriorPartition,SteelFramed,,,Metal Framed Wall - 24inOC - 2x4 - R0 ins.,,,,, +int_wall_smallhotel,InteriorWall,,,,1/2 in. Gypsum Board,1/2 in. Gypsum Board,,,, +LargeHotel Interior Wall,InteriorWall,,,,G01 13mm gypsum board,G01 13mm gypsum board,,,, +NACM_Interior Wall,InteriorWall,,,,NACM_Gypsum Board 5/8in,NACM_Gypsum Board 5/8in,,,, +Typical Insulated Interior Wall,InteriorWall,WoodFramed,Typical Insulation,,25mm Stucco,5/8 in. Gypsum Board,Typical Insulation,Steel Frame/Cavity,5/8 in. Gypsum Board, +Typical Interior Wall,InteriorWall,,,,G01 13mm gypsum board,G01 13mm gypsum board,,,, +Typical Uninsulated Interior Wall,InteriorWall,WoodFramed,,,1/2 in. Gypsum Board,1/2 in. Gypsum Board,,,, +Typical Interior Window,InteriorWindow,,,,CLEAR 3MM,,,,, +U 0.58 SHGC 0.19 Simple Glazing Skylight,Skylight,Glass with Curb,,,U 0.58 SHGC 0.19 Simple Glazing,,,,, +U 0.58 SHGC 0.36 Simple Glazing Skylight,Skylight,Glass with Curb,,,U 0.58 SHGC 0.36 Simple Glazing,,,,, +U 1.98 SHGC 0.61 Simple Glazing Skylight,Skylight,Glass with Curb,,,U 1.98 SHGC 0.61 Simple Glazing,,,,, +Window_U_0.50_SHGC_0.40_Skylight_Frame_Width_0.000_in,Skylight,,,Skylight_Frame_Width_0.000_in,Glass_2052_LayerAvg,Gap_1_W_0_0038,Glass_2027F_LayerAvg,,, +Window_U_0.50_SHGC_0.40_Skylight_Frame_Width_0.334_in,Skylight,,,Skylight_Frame_Width_0.334_in,Glass_2052_LayerAvg,Gap_1_W_0_0038,Glass_2027F_LayerAvg,,, +Window_U_0.50_SHGC_0.40_Skylight_Frame_Width_0.430_in,Skylight,,,Skylight_Frame_Width_0.430_in,Glass_2052_LayerAvg,Gap_1_W_0_0038,Glass_2027F_LayerAvg,,, +Window_U_0.55_SHGC_0.35_Skylight_Frame_Width_0.709_in,Skylight,,,Skylight_Frame_Width_0.709_in,Glass_2052_LayerAvg,Gap_1_W_0_0038,Glass_2027F_LayerAvg,,, +Window_U_0.65_SHGC_0.35_Skylight_Frame_Width_2.339_in,Skylight,,,Skylight_Frame_Width_2.339_in,Glass_2052_LayerAvg,Gap_1_W_0_0024,Glass_2027F_LayerAvg,,, +Window_U_0.75_SHGC_0.35_Skylight_Frame_Width_2.339_in,Skylight,,,Skylight_Frame_Width_2.339_in,Glass_2052_LayerAvg,Gap_1_W_0_0018,Glass_2027F_LayerAvg,,, +U 0.60 SHGC 0.25 Dbl 2.5mm air,,,,,Glass_2175_LayerAvg,Gap_1_W_0_0025,Glass_2022F_LayerAvg,,, +U 0.61 SHGC 0.77 Simple Glazing Skylight,,,,,U 0.61 SHGC 0.77 Simple Glazing,,,,, +U 0.65 SHGC 0.35 Simple Glazing Skylight,,,,,U 0.65 SHGC 0.35 Simple Glazing,,,,, +U 0.69 SHGC 0.19 Simple Glazing Skylight,,,,,U 0.69 SHGC 0.19 Simple Glazing,,,,, +U 0.69 SHGC 0.36 Simple Glazing Skylight,,,,,U 0.69 SHGC 0.36 Simple Glazing,,,,, +U 0.69 SHGC 0.39 Simple Glazing Skylight,,,,,U 0.69 SHGC 0.39 Simple Glazing,,,,, +U 0.69 SHGC 0.49 Simple Glazing Skylight,,,,,U 0.69 SHGC 0.49 Simple Glazing,,,,, +U 0.69 SHGC 0.64 Simple Glazing Skylight,,,,,U 0.69 SHGC 0.64 Simple Glazing,,,,, +U 0.69 SHGC 0.68 Simple Glazing Skylight,,,,,U 0.69 SHGC 0.68 Simple Glazing,,,,, +U 0.74 SHGC 0.55 Simple Glazing Skylight,,,,,U 0.74 SHGC 0.55 Simple Glazing,,,,, +U 0.74 SHGC 0.65 Simple Glazing Skylight,,,,,U 0.74 SHGC 0.65 Simple Glazing,,,,, +U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,,U 0.75 SHGC 0.35 Simple Glazing,,,,, +U 0.81 SHGC 0.65 Simple Glazing Skylight,,,,,U 0.81 SHGC 0.65 Simple Glazing,,,,, +U 0.85 SHGC 0.65 Simple Glazing Skylight,,,,,U 0.85 SHGC 0.65 Simple Glazing,,,,, +U 0.87 SHGC 0.58 Simple Glazing Skylight,,,,,U 0.87 SHGC 0.58 Simple Glazing,,,,, +U 0.87 SHGC 0.71 Simple Glazing Skylight,,,,,U 0.87 SHGC 0.71 Simple Glazing,,,,, +U 0.87 SHGC 0.77 Simple Glazing Skylight,,,,,U 0.87 SHGC 0.77 Simple Glazing,,,,, +U 0.98 SHGC 0.19 Simple Glazing Skylight,,,,,U 0.98 SHGC 0.19 Simple Glazing,,,,, +U 0.98 SHGC 0.36 Simple Glazing Skylight,,,,,U 0.98 SHGC 0.36 Simple Glazing,,,,, +U 1.10 SHGC 0.62 Simple Glazing Skylight,,,,,U 1.10 SHGC 0.62 Simple Glazing,,,,, +U 1.10 SHGC 0.77 Simple Glazing Skylight,,,,,U 1.10 SHGC 0.77 Simple Glazing,,,,, +U 1.15 SHGC 0.77 Simple Glazing Skylight,,,,,U 1.15 SHGC 0.77 Simple Glazing,,,,, +U 1.17 SHGC 0.19 Simple Glazing Skylight,,,,,U 1.17 SHGC 0.19 Simple Glazing,,,,, +U 1.17 SHGC 0.36 Simple Glazing Skylight,,,,,U 1.17 SHGC 0.36 Simple Glazing,,,,, +U 1.17 SHGC 0.39 Simple Glazing Skylight,,,,,U 1.17 SHGC 0.39 Simple Glazing,,,,, +U 1.17 SHGC 0.49 Simple Glazing Skylight,,,,,U 1.17 SHGC 0.49 Simple Glazing,,,,, +U 1.17 SHGC 0.64 Simple Glazing Skylight,,,,,U 1.17 SHGC 0.64 Simple Glazing,,,,, +U 1.17 SHGC 0.68 Simple Glazing Skylight,,,,,U 1.17 SHGC 0.68 Simple Glazing,,,,, +U 1.30 SHGC 0.27 Simple Glazing Skylight,,,,,U 1.30 SHGC 0.27 Simple Glazing,,,,, +U 1.30 SHGC 0.34 Simple Glazing Skylight,,,,,U 1.30 SHGC 0.34 Simple Glazing,,,,, +U 1.30 SHGC 0.62 Simple Glazing Skylight,,,,,U 1.30 SHGC 0.62 Simple Glazing,,,,, +U 1.30 SHGC 0.65 Simple Glazing Skylight,,,,,U 1.30 SHGC 0.65 Simple Glazing,,,,, +U 1.36 SHGC 0.19 Simple Glazing Skylight,,,,,U 1.36 SHGC 0.19 Simple Glazing,,,,, +U 1.36 SHGC 0.36 Simple Glazing Skylight,,,,,U 1.36 SHGC 0.36 Simple Glazing,,,,, +U 1.36 SHGC 0.39 Simple Glazing Skylight,,,,,U 1.36 SHGC 0.39 Simple Glazing,,,,, +U 1.36 SHGC 0.61 Simple Glazing Skylight,,,,,U 1.36 SHGC 0.61 Simple Glazing,,,,, +U 1.70 SHGC 0.36 Simple Glazing Skylight,,,,,U 1.70 SHGC 0.36 Simple Glazing,,,,, +U 1.80 SHGC 0.36 Simple Glazing Skylight,,,,,U 1.80 SHGC 0.36 Simple Glazing,,,,, +U 1.90 SHGC 0.27 Simple Glazing Skylight,,,,,U 1.90 SHGC 0.27 Simple Glazing,,,,, +U 1.90 SHGC 0.34 Simple Glazing Skylight,,,,,U 1.90 SHGC 0.34 Simple Glazing,,,,, +U 1.90 SHGC 0.39 Simple Glazing Skylight,,,,,U 1.90 SHGC 0.39 Simple Glazing,,,,, +U 1.90 SHGC 0.65 Simple Glazing Skylight,,,,,U 1.90 SHGC 0.65 Simple Glazing,,,,, +U 1.98 SHGC 0.16 Simple Glazing Skylight,,,,,U 1.98 SHGC 0.16 Simple Glazing,,,,, +U 1.98 SHGC 0.19 Simple Glazing Skylight,,,,,U 1.98 SHGC 0.19 Simple Glazing,,,,, +U 1.98 SHGC 0.36 Simple Glazing Skylight,,,,,U 1.98 SHGC 0.36 Simple Glazing,,,,, +U 1.98 SHGC 0.39 Simple Glazing Skylight,,,,,U 1.98 SHGC 0.39 Simple Glazing,,,,, +U 0.49 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.49 SHGC 0.22 Simple Glazing,,,,, +U 0.57 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.57 SHGC 0.25 Simple Glazing,,,,, +U 0.53 SHGC 0.25 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.53 SHGC 0.25 Simple Glazing,,,,, +U 0.48 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.48 SHGC 0.25 Simple Glazing,,,,, +U 0.38 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.38 SHGC 0.36 Simple Glazing,,,,, +U 0.38 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.38 SHGC 0.38 Simple Glazing,,,,, +U 0.36 SHGC 0.4 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.36 SHGC 0.4 Simple Glazing,,,,, +U 0.33 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.33 SHGC 0.45 Simple Glazing,,,,, +U 0.29 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.29 SHGC 0.45 Simple Glazing,,,,, +U 0.5 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.5 SHGC 0.22 Simple Glazing,,,,, +U 0.54 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.54 SHGC 0.25 Simple Glazing,,,,, +U 0.49 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.49 SHGC 0.25 Simple Glazing,,,,, +U 0.45 SHGC 0.25 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.45 SHGC 0.25 Simple Glazing,,,,, +U 1.19 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 1.19 SHGC 0.45 Simple Glazing,,,,, +U 0.73 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.73 SHGC 0.45 Simple Glazing,,,,, +U 0.62 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.62 SHGC 0.45 Simple Glazing,,,,, +U 0.51 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.51 SHGC 0.45 Simple Glazing,,,,, +U 0.38 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.38 SHGC 0.45 Simple Glazing,,,,, +U 0.53 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.53 SHGC 0.22 Simple Glazing,,,,, +U 0.53 SHGC 0.23 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.53 SHGC 0.23 Simple Glazing,,,,, +U 0.38 SHGC 0.35 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.38 SHGC 0.35 Simple Glazing,,,,, +U 0.38 SHGC 0.37 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.38 SHGC 0.37 Simple Glazing,,,,, +U 0.36 SHGC 0.37 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.36 SHGC 0.37 Simple Glazing,,,,, +U 0.31 SHGC 0.39 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.31 SHGC 0.39 Simple Glazing,,,,, +U 0.28 SHGC 0.39 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.28 SHGC 0.39 Simple Glazing,,,,, +U 0.51 SHGC 0.22 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.51 SHGC 0.22 Simple Glazing,,,,, +U 0.51 SHGC 0.23 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.51 SHGC 0.23 Simple Glazing,,,,, +U 0.46 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.46 SHGC 0.25 Simple Glazing,,,,, +U 0.43 SHGC 0.25 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.43 SHGC 0.25 Simple Glazing,,,,, +U 0.36 SHGC 0.36 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.36 SHGC 0.36 Simple Glazing,,,,, +U 0.36 SHGC 0.38 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.36 SHGC 0.38 Simple Glazing,,,,, +U 0.34 SHGC 0.38 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.34 SHGC 0.38 Simple Glazing,,,,, +U 0.29 SHGC 0.4 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.29 SHGC 0.4 Simple Glazing,,,,, +U 0.26 SHGC 0.4 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.26 SHGC 0.4 Simple Glazing,,,,, +U 0.37 SHGC 0.36 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.37 SHGC 0.36 Simple Glazing,,,,, +U 0.37 SHGC 0.38 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.37 SHGC 0.38 Simple Glazing,,,,, +U 0.35 SHGC 0.38 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.35 SHGC 0.38 Simple Glazing,,,,, +U 0.3 SHGC 0.4 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.3 SHGC 0.4 Simple Glazing,,,,, +U 0.27 SHGC 0.4 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.27 SHGC 0.4 Simple Glazing,,,,, +U 0.5 SHGC 0.23 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.5 SHGC 0.23 Simple Glazing,,,,, +U 0.42 SHGC 0.25 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.42 SHGC 0.25 Simple Glazing,,,,, +U 0.47 SHGC 0.25 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.47 SHGC 0.25 Simple Glazing,,,,, +U 1.2 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 1.2 SHGC 0.45 Simple Glazing,,,,, +U 0.5 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.5 SHGC 0.45 Simple Glazing,,,,, +U 0.39 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.39 SHGC 0.45 Simple Glazing,,,,, +U 0.36 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.36 SHGC 0.45 Simple Glazing,,,,, +U 0.75 SHGC 0.35 Simple Glazing Window,Skylight,Weighted,,,U 0.75 SHGC 0.35 Simple Glazing Window,,,,, +U 0.65 SHGC 0.35 Simple Glazing Window,Skylight,Weighted,,,U 0.65 SHGC 0.35 Simple Glazing Window,,,,, +U 0.55 SHGC 0.35 Simple Glazing Window,Skylight,Weighted,,,U 0.55 SHGC 0.35 Simple Glazing,,,,, +U 0.5 SHGC 0.4 Simple Glazing Window,Skylight,Weighted,,,U 0.5 SHGC 0.4 Simple Glazing,,,,, +U 0.5 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 0.5 SHGC 0.55 Simple Glazing,,,,, +U 0.41 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 0.41 SHGC 0.55 Simple Glazing,,,,, +U 1.8 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 1.8 SHGC 0.55 Simple Glazing,,,,, +U 1.7 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 1.7 SHGC 0.55 Simple Glazing,,,,, +U 1.15 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 1.15 SHGC 0.55 Simple Glazing,,,,, +U 0.98 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 0.98 SHGC 0.55 Simple Glazing,,,,, +U 0.85 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 0.85 SHGC 0.55 Simple Glazing,,,,, +U 0.7 SHGC 0.3 Simple Glazing Window,Skylight,Weighted,,,U 0.7 SHGC 0.3 Simple Glazing,,,,, +U 0.65 SHGC 0.3 Simple Glazing Window,Skylight,Weighted,,,U 0.65 SHGC 0.3 Simple Glazing,,,,, +U 0.55 SHGC 0.3 Simple Glazing Window,Skylight,Weighted,,,U 0.55 SHGC 0.3 Simple Glazing,,,,, +U 0.47 SHGC 0.4 Simple Glazing Window,Skylight,Weighted,,,U 0.47 SHGC 0.4 Simple Glazing,,,,, +U 0.44 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 0.44 SHGC 0.55 Simple Glazing,,,,, +U 0.9 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 0.9 SHGC 0.55 Simple Glazing,,,,, +U 0.75 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 0.75 SHGC 0.55 Simple Glazing,,,,, +U 0.37 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.37 SHGC 0.25 Simple Glazing,,,,, +U 0.83 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.83 SHGC 0.25 Simple Glazing,,,,, +U 0.77 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.77 SHGC 0.25 Simple Glazing,,,,, +U 0.93 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.93 SHGC 0.45 Simple Glazing,,,,, +U 0.83 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.83 SHGC 0.45 Simple Glazing,,,,, +U 0.65 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 0.65 SHGC 0.55 Simple Glazing,,,,, +U 1.8 SHGC 0.77 Simple Glazing Skylight,Skylight,Weighted,,,U 1.8 SHGC 0.77 Simple Glazing,,,,, +U 0.65 SHGC 0.77 Simple Glazing Skylight,Skylight,Weighted,,,U 0.65 SHGC 0.77 Simple Glazing,,,,, +U 1.8 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 1.8 SHGC 0.55 Simple Glazing,,,,, +U 0.65 SHGC 0.68 Simple Glazing Skylight,Skylight,Weighted,,,U 0.65 SHGC 0.68 Simple Glazing,,,,, +U 1.8 SHGC 0.64 Simple Glazing Skylight,Skylight,Weighted,,,U 1.8 SHGC 0.64 Simple Glazing,,,,, +U 0.33 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.33 SHGC 0.25 Simple Glazing,,,,, +U 0.68 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.68 SHGC 0.25 Simple Glazing,,,,, +U 0.87 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.87 SHGC 0.45 Simple Glazing,,,,, +U 0.77 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.77 SHGC 0.45 Simple Glazing,,,,, +U 0.55 SHGC 0.64 Simple Glazing Skylight,Skylight,Weighted,,,U 0.55 SHGC 0.64 Simple Glazing,,,,, +U 0.55 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 0.55 SHGC 0.55 Simple Glazing,,,,, +U 1.7 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 1.7 SHGC 0.55 Simple Glazing,,,,, +U 0.31 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.31 SHGC 0.36 Simple Glazing,,,,, +U 0.68 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.68 SHGC 0.36 Simple Glazing,,,,, +U 0.5 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 0.5 SHGC 0.55 Simple Glazing,,,,, +U 1.15 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 1.15 SHGC 0.55 Simple Glazing,,,,, +U 0.31 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.31 SHGC 0.38 Simple Glazing,,,,, +U 0.68 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.68 SHGC 0.38 Simple Glazing,,,,, +U 0.45 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.45 SHGC 0.45 Simple Glazing,,,,, +U 0.5 SHGC 0.36 Simple Glazing Skylight,Skylight,Weighted,,,U 0.5 SHGC 0.36 Simple Glazing,,,,, +U 0.5 SHGC 0.19 Simple Glazing Skylight,Skylight,Weighted,,,U 0.5 SHGC 0.19 Simple Glazing,,,,, +U 0.98 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 0.98 SHGC 0.55 Simple Glazing,,,,, +U 0.5 SHGC 0.34 Simple Glazing Skylight,Skylight,Weighted,,,U 0.5 SHGC 0.34 Simple Glazing,,,,, +U 0.98 SHGC 0.27 Simple Glazing Skylight,Skylight,Weighted,,,U 0.98 SHGC 0.27 Simple Glazing,,,,, +U 0.68 SHGC 0.4 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.68 SHGC 0.4 Simple Glazing,,,,, +U 0.85 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 0.85 SHGC 0.55 Simple Glazing,,,,, +U 0.85 SHGC 0.19 Simple Glazing Skylight,Skylight,Weighted,,,U 0.85 SHGC 0.19 Simple Glazing,,,,, +U 0.85 SHGC 0.39 Simple Glazing Skylight,Skylight,Weighted,,,U 0.85 SHGC 0.39 Simple Glazing,,,,, +U 0.28 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.28 SHGC 0.45 Simple Glazing,,,,, +U 0.68 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.68 SHGC 0.45 Simple Glazing,,,,, +U 0.32 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.32 SHGC 0.45 Simple Glazing,,,,, +U 0.5 SHGC 0.27 Simple Glazing Skylight,Skylight,Weighted,,,U 0.5 SHGC 0.27 Simple Glazing,,,,, +U 0.25 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.25 SHGC 0.45 Simple Glazing,,,,, +U 0.5 SHGC 0.39 Simple Glazing Skylight,Skylight,Weighted,,,U 0.5 SHGC 0.39 Simple Glazing,,,,, +U 0.5 SHGC 0.65 Simple Glazing Skylight,Skylight,Weighted,,,U 0.5 SHGC 0.65 Simple Glazing,,,,, +U 0.85 SHGC 0.27 Simple Glazing Skylight,Skylight,Weighted,,,U 0.85 SHGC 0.27 Simple Glazing,,,,, +U 0.5 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.5 SHGC 0.25 Simple Glazing,,,,, +U 1.1 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 1.1 SHGC 0.25 Simple Glazing,,,,, +U 1.1 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 1.1 SHGC 0.45 Simple Glazing,,,,, +U 0.75 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 0.75 SHGC 0.55 Simple Glazing,,,,, +U 0.75 SHGC 0.49 Simple Glazing Skylight,Skylight,Weighted,,,U 0.75 SHGC 0.49 Simple Glazing,,,,, +U 1.8 SHGC 0.49 Simple Glazing Skylight,Skylight,Weighted,,,U 1.8 SHGC 0.49 Simple Glazing,,,,, +U 0.75 SHGC 0.39 Simple Glazing Skylight,Skylight,Weighted,,,U 0.75 SHGC 0.39 Simple Glazing,,,,, +U 0.75 SHGC 0.68 Simple Glazing Skylight,Skylight,Weighted,,,U 0.75 SHGC 0.68 Simple Glazing,,,,, +U 0.75 SHGC 0.64 Simple Glazing Skylight,Skylight,Weighted,,,U 0.75 SHGC 0.64 Simple Glazing,,,,, +U 0.77 SHGC 0.23 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.77 SHGC 0.23 Simple Glazing,,,,, +U 0.68 SHGC 0.23 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.68 SHGC 0.23 Simple Glazing,,,,, +U 0.63 SHGC 0.33 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.63 SHGC 0.33 Simple Glazing,,,,, +U 0.63 SHGC 0.34 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.63 SHGC 0.34 Simple Glazing,,,,, +U 0.63 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.63 SHGC 0.36 Simple Glazing,,,,, +U 0.63 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.63 SHGC 0.45 Simple Glazing,,,,, +U 0.55 SHGC 0.35 Simple Glazing Skylight,Skylight,,,,U 0.55 SHGC 0.35 Simple Glazing,,,,, +U 0.5 SHGC 0.4 Simple Glazing Skylight,Skylight,,,,U 0.5 SHGC 0.4 Simple Glazing,,,,, +U 0.41 SHGC 0.55 Simple Glazing Skylight,Skylight,,,,U 0.41 SHGC 0.55 Simple Glazing,,,,, +U 0.6 SHGC 0.23 Simple Glazing Window,ExteriorWindow,,,,U 0.6 SHGC 0.23 Simple Glazing,,,,, +U 0.65 SHGC 0.3 Simple Glazing Skylight,Skylight,,,,U 0.65 SHGC 0.3 Simple Glazing,,,,, +U 0.55 SHGC 0.3 Simple Glazing Skylight,Skylight,,,,U 0.55 SHGC 0.3 Simple Glazing,,,,, +U 0.47 SHGC 0.4 Simple Glazing Skylight,Skylight,,,,U 0.47 SHGC 0.4 Simple Glazing,,,,, +U 0.44 SHGC 0.55 Simple Glazing Skylight,Skylight,,,,U 0.44 SHGC 0.55 Simple Glazing,,,,, +U 0.83 SHGC 0.21 Simple Glazing Window,ExteriorWindow,,,,U 0.83 SHGC 0.21 Simple Glazing,,,,, +U 0.7 SHGC 0.3 Simple Glazing Skylight,Skylight,,,,U 0.7 SHGC 0.3 Simple Glazing,,,,, +U 0.32 SHGC 0.22 Simple Glazing Window,ExteriorWindow,,,,U 0.32 SHGC 0.22 Simple Glazing,,,,, +U 0.83 SHGC 0.22 Simple Glazing Window,ExteriorWindow,,,,U 0.83 SHGC 0.22 Simple Glazing,,,,, +U 0.83 SHGC 0.2 Simple Glazing Window,ExteriorWindow,,,,U 0.83 SHGC 0.2 Simple Glazing,,,,, +U 0.62 SHGC 0.2 Simple Glazing Window,ExteriorWindow,,,,U 0.62 SHGC 0.2 Simple Glazing,,,,, +U 1.22 SHGC 0.19 Simple Glazing Window,ExteriorWindow,,,,U 1.22 SHGC 0.19 Simple Glazing,,,,, +U 1.22 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 1.22 SHGC 0.45 Simple Glazing,,,,, +U 1.22 SHGC 0.17 Simple Glazing Window,ExteriorWindow,,,,U 1.22 SHGC 0.17 Simple Glazing,,,,, +U 1.22 SHGC 0.39 Simple Glazing Window,ExteriorWindow,,,,U 1.22 SHGC 0.39 Simple Glazing,,,,, +U 0.98 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.98 SHGC 0.45 Simple Glazing,,,,, +U 1.98 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 1.98 SHGC 0.45 Simple Glazing,,,,, +U 0.57 SHGC 0.39 Simple Glazing Window,ExteriorWindow,,,,U 0.57 SHGC 0.39 Simple Glazing,,,,, +U 0.46 SHGC 0.19 Simple Glazing Window,ExteriorWindow,,,,U 0.46 SHGC 0.19 Simple Glazing,,,,, +U 1.98 SHGC 0.34 Simple Glazing Skylight,Skylight,,,,U 1.98 SHGC 0.34 Simple Glazing,,,,, +U 1.22 SHGC 0.61 Simple Glazing Window,ExteriorWindow,,,,U 1.22 SHGC 0.61 Simple Glazing,,,,, +U 1.22 SHGC 0.34 Simple Glazing Window,ExteriorWindow,,,,U 1.22 SHGC 0.34 Simple Glazing,,,,, +U 0.57 SHGC 0.49 Simple Glazing Window,ExteriorWindow,,,,U 0.57 SHGC 0.49 Simple Glazing,,,,, +U 0.46 SHGC 0.26 Simple Glazing Window,ExteriorWindow,,,,U 0.46 SHGC 0.26 Simple Glazing,,,,, +U 0.98 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 0.98 SHGC 0.45 Simple Glazing,,,,, +U 1.98 SHGC 0.65 Simple Glazing Skylight,Skylight,,,,U 1.98 SHGC 0.65 Simple Glazing,,,,, +U 0.58 SHGC 0.61 Simple Glazing Skylight,Skylight,,,,U 0.58 SHGC 0.61 Simple Glazing,,,,, +U 0.46 SHGC 0.36 Simple Glazing Window,ExteriorWindow,,,,U 0.46 SHGC 0.36 Simple Glazing,,,,, +U 0.46 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.46 SHGC 0.45 Simple Glazing,,,,, +U 0.35 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.35 SHGC 0.45 Simple Glazing,,,,, +U 0.98 SHGC 0.62 Simple Glazing Skylight,Skylight,,,,U 0.98 SHGC 0.62 Simple Glazing,,,,, +U 0.58 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 0.58 SHGC 0.45 Simple Glazing,,,,, +U 0.75 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.75 SHGC 0.25 Simple Glazing,,,,, +U 0.7 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.7 SHGC 0.25 Simple Glazing,,,,, +U 1.98 SHGC 0.49 Simple Glazing Skylight,Skylight,,,,U 1.98 SHGC 0.49 Simple Glazing,,,,, +U 0.65 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.65 SHGC 0.25 Simple Glazing,,,,, +U 0.6 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.6 SHGC 0.25 Simple Glazing,,,,, +U 0.9 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.9 SHGC 0.25 Simple Glazing,,,,, +U 1.98 SHGC 0.71 Simple Glazing Skylight,Skylight,,,,U 1.98 SHGC 0.71 Simple Glazing,,,,, +U 0.4 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.4 SHGC 0.4 Simple Glazing,,,,, +U 0.55 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.55 SHGC 0.4 Simple Glazing,,,,, +U 0.85 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.85 SHGC 0.4 Simple Glazing,,,,, +U 0.35 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.35 SHGC 0.4 Simple Glazing,,,,, +U 0.45 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.45 SHGC 0.4 Simple Glazing,,,,, +U 0.8 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.8 SHGC 0.4 Simple Glazing,,,,, +U 0.65 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.65 SHGC 0.45 Simple Glazing,,,,, +U 0.6 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.6 SHGC 0.45 Simple Glazing,,,,, +U 0.9 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.9 SHGC 0.45 Simple Glazing,,,,, +U 0.4 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.4 SHGC 0.45 Simple Glazing,,,,, +U 0.8 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.8 SHGC 0.45 Simple Glazing,,,,, +U 1.2 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 1.2 SHGC 0.25 Simple Glazing,,,,, +U 1.98 SHGC 0.27 Simple Glazing Skylight,Skylight,,,,U 1.98 SHGC 0.27 Simple Glazing,,,,, +U 1.17 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 1.17 SHGC 0.45 Simple Glazing,,,,, +U 0.98 SHGC 0.49 Simple Glazing Skylight,Skylight,,,,U 0.98 SHGC 0.49 Simple Glazing,,,,, +U 0.98 SHGC 0.46 Simple Glazing Skylight,Skylight,,,,U 0.98 SHGC 0.46 Simple Glazing,,,,, +U 0.58 SHGC 0.65 Simple Glazing Skylight,Skylight,,,,U 0.58 SHGC 0.65 Simple Glazing,,,,, +U 0.58 SHGC 0.55 Simple Glazing Skylight,Skylight,,,,U 0.58 SHGC 0.55 Simple Glazing,,,,, +U 0.4 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.4 SHGC 0.25 Simple Glazing,,,,, +U 0.65 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 0.65 SHGC 0.45 Simple Glazing,,,,, +U 0.35 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.35 SHGC 0.25 Simple Glazing,,,,, +U 0.55 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 0.55 SHGC 0.45 Simple Glazing,,,,, +U 0.42 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.42 SHGC 0.4 Simple Glazing,,,,, +U 0.77 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.77 SHGC 0.4 Simple Glazing,,,,, +U 0.81 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.81 SHGC 0.45 Simple Glazing,,,,, +U 0.5 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 0.5 SHGC 0.45 Simple Glazing,,,,, +U 0.32 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.32 SHGC 0.4 Simple Glazing,,,,, +U 0.7 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.7 SHGC 0.45 Simple Glazing,,,,, +U 0.59 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.59 SHGC 0.45 Simple Glazing,,,,, +U 0.44 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.44 SHGC 0.45 Simple Glazing,,,,, +U 0.93 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.93 SHGC 0.25 Simple Glazing,,,,, +U 0.75 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 0.75 SHGC 0.45 Simple Glazing,,,,, +U 0.3 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.3 SHGC 0.4 Simple Glazing,,,,, +U 0.36 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.36 SHGC 0.4 Simple Glazing,,,,, +U 0.9 SHGC 0.55 Simple Glazing Skylight,Skylight,,,,U 0.9 SHGC 0.55 Simple Glazing,,,,, +U 0.48 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.48 SHGC 0.45 Simple Glazing,,,,, diff --git a/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.csv b/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.csv new file mode 100644 index 0000000000..6cc1ce0e8f --- /dev/null +++ b/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.csv @@ -0,0 +1,155 @@ +support_electric_equipment_space_type_name_tags +corridor - all other +dining - all other +electrical/mechanical +kitchen +laboratory +lobby - all other +locker room +lounge/breakroom - all other +office - enclosed <= 250 sf +office - enclosed > 250 sf +office - open +restroom - all other +stairwell +storage < 50 sf - all other +storage 50 to 1000 sf - all other +vehicular maintenance +atrium - first three floors +audience seating - convention center +classroom/lecture/training - all other +conference/meeting/multipurpose +exhibit - convention center +gymnasium exercise area +gymnasium playing area +laundry/washing +lobby - elevator +nurses station +post office - sorting area +"sports arena playing area, class IV" +audience seating - all other +confinement cells +judges chambers +library - stacks +storage - inactive +dining - bar/lounge/leisure +dining - cafeteria/fast food +dining - family +computer room +dormitory - living quarters +audience seating - exercise center +exam/treatment +library - reading +emergency vehicle garage +firestation - sleeping quarters +"parking area, interior" +audience seating - gymnasium +emergency room +patient room +corridor - hospital +fellowship hall - religious facility +lounge/breakroom - healthcare facility +operating room +physical therapy +storage < 50 sf - hospital +storage 50 to 1000 sf - hospital +guest room +lobby - hotel +library - cataloging +museum exhibit area +corridor - manufacturing facility +manufacturing equipment room +manufacturing low bay +performing arts dressing room +audience seating - auditorium +audience seating - motion picture theater +lobby - motion picture theater +Dwelling Unit +museum restoration +banking activity +warehouse - fine storage +classroom/lecture/training - penitentiary +dining - penitentiary +audience seating - performing arts theater +lobby - performing arts theater +audience seating - religious facility +worship/pulpit/choir area +classroom/lecture/training - preschool to 12th +"sports arena playing area, class II" +audience seating - sports arena +airport concourse +atrium < 20 ft height +atrium > 40 ft height +atrium >= 20 ft and <= 40 ft in height +baggage/carousel +"seating area, general" +transportation ticket counter +warehouse - bulk storage +workshop +gymnasium_playing_area +gymnasium_exercise_area +courtroom +confinement_cells +judges_chambers +emergency_vehicle_garage +firestation_sleeping_quarters +post_office_sorting_area +exhibit_convention_center +library_cataloging +library_stacks +library_reading +emergency_room +recovery +nurses_station +exam_treatment +pharmacy +patient_room +operating_room +nursery +medical_supply +physical_therapy +imaging +laundry_washing +automotive +manufacturing_low_bay +manufacturing_high_bay +detailed_manufacuring +manufacturing_equipment_room +manufacturing_control +manufacturing_extra_high_bay +guest_room +dormitory_living_quarters +museum_exhibit_area +museum_restoration +banking_activity +worship_pulpit_choir_area +fellowship_hall_religious_facility +sales +retail_mall_concourse +retail_dressing_room +sports_arena_ring_sports_area +sports_arena_court_sports_area +sports_arena_indoor_playing_field +sports_arena_playing_area_class_I +sports_arena_playing_area_class_II +sports_arena_playing_area_class_III +sports_arena_playing_area_class_IV +warehouse_fine_storage +warehouse_bulk_storage +parking_area_interior +airport_concourse +baggage_carousel +transportation_ticket_counter +sales_display_type_1 +sales_display_type_2 +sales_display_type_3 +sales_display_type_4 +breakroom +copy_print +computer_room +loading_dock +locker_room +seating_area_general +vehicular_maintenance +chapel_visually_impaired +recreation_common_living_visually_impaired diff --git a/data/openstudio_standards_data/database_files/support_lighting_space_type_name_tags.csv b/data/openstudio_standards_data/database_files/support_lighting_space_type_name_tags.csv new file mode 100644 index 0000000000..aa285798d8 --- /dev/null +++ b/data/openstudio_standards_data/database_files/support_lighting_space_type_name_tags.csv @@ -0,0 +1,159 @@ +lighting_space_type_name +bam_automotive_facility +bam_convention_center +bam_courthouse +bam_dinin_bar_lounge_leisure +bam_dining_cafeteria_fast_food +bam_dining_family +bam_dormitory +bam_exercise_center +bam_fire_station +bam_gymnasium +bam_healthcare_clinic +bam_hospital +bam_hotel +bam_library +bam_manufacturing_facility +bam_motel +bam_motion_picture_theater +bam_multifamily +bam_museum +bam_office +bam_parking_garage +bam_penitentiary +bam_performing_arts_theater +bam_police_station +bam_post_office +bam_religious_facility +bam_retail +bam_school_university +bam_sports_arena +bam_town_hall +bam_transportation +bam_warehouse +bam_workshop +office_enclosed_small +office_enclosed_large +office_open +conference_meeting_multipurpose +classroom_lecture_training_general +classroom_lecture_training_penitentiary +lobby_general +lobby_hotel +lobby_performing_arts_theater +lobby_motion_picture_theater +lobby_visually_impaired +lobby_elevator +audience_seating_general +audience_seating_gymnasium +audience_seating_exercise_center +audience_seating_convention_center +audience_seating_penitentiary +audience_seating_religious_facility +audience_seating_sports_arena +audience_seating_performing_arts_theater +audience_seating_motion_picture_theater +audience_seating_transportation +audience_seating_auditorium +atrium_first_three_floor +atrium_each_additional_floor +atrium_low +atrium_medium +atrium_high +lounge_breakroom_general +lounge_breakroom_healthcare_facility +dining_general +dining_penitentiary +dining_hotel +dining_motel +dining_bar_lounge_leisure +dining_family +dining_cafeteria_fast_food +dining_visually_impaired +kitchen +laboratory_classroom +laboratory_all_other +restroom_visually_impaired +restroom_all_other +performing_arts_dressing_room +corridor_general +corridor_hospital +corridor_manufacturing_facility +corridor_visually_impaired +stairway +stairwell +storage_ all_other_small +storage_ all_other_large +storage_hospital_small +storage_hospital_large +storage_inactive +storage_inactive_museum +electrical_mechanical +workshop +gymnasium_playing_area +gymnasium_exercise_area +courtroom +confinement_cells +judges_chambers +emergency_vehicle_garage +firestation_sleeping_quarters +post_office_sorting_area +exhibit_convention_center +library_cataloging +library_stacks +library_reading +emergency_room +recovery +nurses_station +exam_treatment +pharmacy +patient_room +operating_room +nursery +medical_supply +physical_therapy +imaging +laundry_washing +automotive +manufacturing_low_bay +manufacturing_high_bay +detailed_manufacuring +manufacturing_equipment_room +manufacturing_control +manufacturing_extra_high_bay +guest_room +dormitory_living_quarters +museum_exhibit_area +museum_restoration +banking_activity +worship_pulpit_choir_area +fellowship_hall_religious_facility +sales +retail_mall_concourse +retail_dressing_room +sports_arena_ring_sports_area +sports_arena_court_sports_area +sports_arena_indoor_playing_field +sports_arena_playing_area_class_I +sports_arena_playing_area_class_II +sports_arena_playing_area_class_III +sports_arena_playing_area_class_IV +warehouse_fine_storage +warehouse_bulk_storage +parking_area_interior +airport_concourse +baggage_carousel +transportation_ticket_counter +sales_display_type_1 +sales_display_type_2 +sales_display_type_3 +sales_display_type_4 +breakroom +copy_print +computer_room +loading_dock +locker_room +seating_area_general +vehicular_maintenance +chapel_visually_impaired +recreation_common_living_visually_impaired diff --git a/data/openstudio_standards_data/database_files/support_materials.csv b/data/openstudio_standards_data/database_files/support_materials.csv new file mode 100644 index 0000000000..2033106c5e --- /dev/null +++ b/data/openstudio_standards_data/database_files/support_materials.csv @@ -0,0 +1,1390 @@ +name,material_type,roughness,thickness,conductivity,resistance,density,specific_heat,thermal_absorptance,solar_absorptance,visible_absorptance,gas_type,u_factor,solar_heat_gain_coefficient,visible_transmittance,optical_data_type,solar_transmittance_at_normal_incidence,front_side_solar_reflectance_at_normal_incidence,back_side_solar_reflectance_at_normal_incidence,visible_transmittance_at_normal_incidence,front_side_visible_reflectance_at_normal_incidence,back_side_visible_reflectance_at_normal_incidence,infrared_transmittance_at_normal_incidence,front_side_infrared_hemispherical_emissivity,back_side_infrared_hemispherical_emissivity,dirt_correction_factor_for_solar_and_visible_transmittance,solar_diffusing,frame_width,annotation +1 Coat Stucco,StandardOpaqueMaterial,MediumRough,0.38,5.0004,0.07599392,115.81,0.2,,,,,,,,,,,,,,,,,,,,, +1/2 in. Gypsum Board,StandardOpaqueMaterial,Smooth,0.5,1.109355488,0.450712153,49.94236846,0.260342027,0.9,0.7,0.5,,,,,,,,,,,,,,,,,, +1/2IN Gypsum,StandardOpaqueMaterial,Smooth,0.5,1.109355488,0.450712153,48.99970626,0.198242094,0.9,0.4,0.4,,,,,,,,,,,,,,,,,, +10 PSF Roof - 1 in.,StandardOpaqueMaterial,VeryRough,1,12.0048,0.083300013,120,0.2,,,,,,,,,,,,,,,,,,,,, +100mm Normalweight concrete floor,StandardOpaqueMaterial,MediumRough,4,16.0194175,0.249696969,144.957816,0.198852772,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +12 in. Normalweight Concrete Floor,StandardOpaqueMaterial,MediumRough,12,16.01631985,0.749235786,144.9577245,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +15 PSF Roof - 1 1/2 in.,StandardOpaqueMaterial,VeryRough,1.5,18.0072,0.083300013,120,0.2,,,,,,,,,,,,,,,,,,,,, +1IN Stucco,StandardOpaqueMaterial,Smooth,0.996062992,4.79657579,0.207661264,115.9911508,0.199914015,0.9,0.7,0.92,,,,,,,,,,,,,,,,,, +25 PSF Roof - 2 1/2 in.,StandardOpaqueMaterial,VeryRough,2.5,30.012,0.083300013,120,0.2,,,,,,,,,,,,,,,,,,,,, +25mm Stucco,StandardOpaqueMaterial,Smooth,1,4.992099695,0.200316512,115.8662948,0.200630553,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +3 Coat Stucco,StandardOpaqueMaterial,MediumRough,0.88,4.3752,0.201133662,116,0.2,,,,,,,,,,,,,,,,,,,,, +4 in. Normalweight Concrete Floor,StandardOpaqueMaterial,MediumRough,4,16.01631985,0.249745262,144.9577245,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +4 in. Normalweight Concrete Wall,StandardOpaqueMaterial,MediumRough,4,16.01631985,0.249745262,144.9577245,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +5 PSF Roof - 1/2 in.,StandardOpaqueMaterial,VeryRough,0.5,6.0024,0.083300013,120,0.2,,,,,,,,,,,,,,,,,,,,, +5/8 in. Gypsum Board,StandardOpaqueMaterial,MediumSmooth,0.625984252,1.109355488,0.56427742,49.94236846,0.260342027,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +5/8 in. Plywood,StandardOpaqueMaterial,Smooth,0.625984252,0.832016616,0.752369893,33.96081055,0.289003535,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +6 in. Heavyweight Concrete Roof,StandardOpaqueMaterial,MediumRough,6,16.01631985,0.374617893,144.9577245,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +6 in. Normalweight Concrete Floor,StandardOpaqueMaterial,MediumRough,6,16.01631985,0.374617893,144.9577245,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +8 in. Concrete Block Basement Wall,StandardOpaqueMaterial,MediumRough,8,9.193783605,0.870153176,114.9923034,0.217827458,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +8 in. Concrete Block Wall,StandardOpaqueMaterial,MediumRough,8,4.992099695,1.602532098,49.94236846,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +8 in. Normalweight Concrete Floor,StandardOpaqueMaterial,MediumRough,8,16.01631985,0.499490524,144.9577245,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +8 in. Normalweight Concrete Wall,StandardOpaqueMaterial,MediumRough,8,16.01631985,0.499490524,144.9577245,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +8IN Concrete HW,StandardOpaqueMaterial,MediumRough,8.003937008,11.99213282,0.667432318,140.0259156,0.199914015,0.9,0.65,0.65,,,,,,,,,,,,,,,,,, +8IN CONCRETE HW RefBldg,StandardOpaqueMaterial,Rough,8,9.089781528,0.880109162,139.8386317,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Acoustic Ceiling,StandardOpaqueMaterial,MediumSmooth,0.5,0.395207893,1.26515692,17.97925265,0.319814656,0.9,0.7,0.2,,,,,,,,,,,,,,,,,, +Acoustic Tile - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,0.3996,1.251251251,18,0.19,,,,,,,,,,,,,,,,,,,,, +Acoustic Tile - 3/4 in.,StandardOpaqueMaterial,MediumSmooth,0.75,0.3996,1.876876877,18,0.19,,,,,,,,,,,,,,,,,,,,, +Acoustic Tile - 3/8 in.,StandardOpaqueMaterial,MediumSmooth,0.38,0.39,0.974358974,18,0.19,,,,,,,,,,,,,,,,,,,,, +Adiabatic Material,MasslessOpaqueMaterial,,,,9999,,,,,,,,,,,,,,,,,,,,,,, +Aggregate - 45 lb/ft3 - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,1.56,0.320512821,45,0.32,,,,,,,,,,,,,,,,,,,,, +Aggregate - 45 lb/ft3 - 5/8 in.,StandardOpaqueMaterial,MediumSmooth,0.63,1.5996,0.393848462,45,0.32,,,,,,,,,,,,,,,,,,,,, +Aggregate - 45 lb/ft3 - on metal lath - 3/4 in.,StandardOpaqueMaterial,MediumSmooth,0.75,1.5996,0.468867217,45,0.32,,,,,,,,,,,,,,,,,,,,, +Aggregate - Perlite - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,1.2996,0.384733764,45,0.32,,,,,,,,,,,,,,,,,,,,, +Aggregate - Perlite - 5/8 in.,StandardOpaqueMaterial,Smooth,0.63,1.5,0.42,45,0.32,,,,,,,,,,,,,,,,,,,,, +Aggregate - Perlite - on metal lath - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,1.7004,0.441072689,45,0.32,,,,,,,,,,,,,,,,,,,,, +Air - Cavity - Wall Roof Ceiling - 4 in. or more,StandardOpaqueMaterial,Smooth,6,6.5196,0.920301859,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Ceiling - 1 1/2 in.,StandardOpaqueMaterial,Smooth,1.5,1.95,0.769230769,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Ceiling - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.6804,0.734861846,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Ceiling - 3 1/2 in.,StandardOpaqueMaterial,Smooth,3.5,4.38,0.799086758,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Ceiling - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,0.9996,0.75030012,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Floor - 1 1/2 in.,StandardOpaqueMaterial,Smooth,1.5,1.5996,0.937734434,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Floor - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.6504,0.768757688,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Floor - 3 1/2 in.,StandardOpaqueMaterial,Smooth,3.5,3.5004,0.999885727,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Floor - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,0.8796,0.8526603,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Metal Wall Framing - 16 or 24 in. OC,StandardOpaqueMaterial,Smooth,5.5,8.46,0.650118203,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Roof - 1 1/2 in.,StandardOpaqueMaterial,Smooth,1.5,1.8804,0.797702616,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Roof - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.66,0.757575758,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Roof - 3 1/2 in.,StandardOpaqueMaterial,Smooth,3.5,4.2696,0.819748923,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Roof - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,0.93,0.806451613,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Wall - 1 1/2 in.,StandardOpaqueMaterial,Smooth,1.5,1.7196,0.872295883,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Wall - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.6504,0.768757688,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Wall - 3 1/2 in.,StandardOpaqueMaterial,Smooth,3.5,4.1196,0.849597048,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +Air - Wall - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,0.8904,0.842318059,0.08,0.24,,,,,,,,,,,,,,,,,,,,, +AIR 13MM,Gas,,0.5,,,,,,,,Air,,,,,,,,,,,,,,,,, +AIR 3MM,Gas,,0.125984252,,,,,,,,Air,,,,,,,,,,,,,,,,, +AIR 6MM,Gas,,0.248031496,,,,,,,,Air,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Double glass with no low e - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.9,2.522222222,29.09,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Double glass with no low e - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.8196,3.989751098,20.44,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Double glass with no low e - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,1.08,4.138888889,15.23,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Double glass with no low e - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,1.3296,4.264440433,12.22,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Double glass with no low e - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,1.5996,4.294823706,10.26,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Double glass with no low e - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.8504,4.361219196,8.88,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Double glass with no low e - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.5304,3.450226244,35.69,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Double glass with no low e - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.6696,3.808243728,25.92,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - No Ins.,StandardOpaqueMaterial,Smooth,2.27,1.1796,1.924381146,29.09,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.8496,3.848870056,20.44,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,1.1004,4.062159215,15.23,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,1.35,4.2,12.22,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,1.6104,4.266020864,10.26,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.86,4.338709677,8.88,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.5604,3.265524625,35.69,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.6996,3.644939966,25.92,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Triple or low e glass - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.78,2.91025641,29.09,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Triple or low e glass - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.8196,3.989751098,20.44,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Triple or low e glass - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,1.08,4.138888889,15.23,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Triple or low e glass - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,1.3296,4.264440433,12.22,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Triple or low e glass - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,1.5996,4.294823706,10.26,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Triple or low e glass - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.8504,4.361219196,8.88,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Triple or low e glass - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.51,3.588235294,35.69,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/ Thrml Break - Triple or low e glass - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.6696,3.808243728,25.92,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Double glass with no low e coatings - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.8304,2.733622351,29.09,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Double glass with no low e coatings - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.6504,5.027675277,20.44,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Double glass with no low e coatings - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.8304,5.382947977,15.23,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Double glass with no low e coatings - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,1.00464,5.643812709,12.22,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Double glass with no low e coatings - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,1.1904,5.771169355,10.26,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Double glass with no low e coatings - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.3704,5.888791594,8.88,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Double glass with no low e coatings - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.4404,4.155313351,35.69,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Double glass with no low e coatings - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.54,4.722222222,25.92,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - No Ins.,StandardOpaqueMaterial,Smooth,2.27,1.1304,2.008138712,29.09,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.66,4.954545455,20.44,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.84,5.321428571,15.23,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,1.0104,5.611638955,12.22,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,1.1904,5.771169355,10.26,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.38,5.847826087,8.88,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.4704,3.890306122,35.69,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.5604,4.550321199,25.92,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Triple or low e glass - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.69,3.289855072,29.09,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Triple or low e glass - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.63648,5.137631976,20.44,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Triple or low e glass - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.8196,5.453879941,15.23,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Triple or low e glass - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,0.9996,5.672268908,12.22,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Triple or low e glass - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,1.1796,5.824008138,10.26,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Triple or low e glass - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.3704,5.888791594,8.88,0.27,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Triple or low e glass - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.41724,4.385964912,35.69,0.26,,,,,,,,,,,,,,,,,,,,, +Aluminum w/out Thrml Break - Triple or low e glass - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.5304,4.807692308,25.92,0.26,,,,,,,,,,,,,,,,,,,,, +ARGON 13MM,Gas,,0.5,,,,,,,,Argon,,,,,,,,,,,,,,,,, +Asbestos or cement shingles - 3/8 in.,StandardOpaqueMaterial,VeryRough,0.38,1.7904,0.212243074,120,0.24,,,,,,,,,,,,,,,,,,,,, +Ash - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,1.1004,0.908760451,40.06,0.39,,,,,,,,,,,,,,,,,,,,, +Asphalt - bitumen with inert fill - 100 lb/ft3 - 3/4 in.,StandardOpaqueMaterial,VeryRough,0.75,3,0.25,100,0.3,,,,,,,,,,,,,,,,,,,,, +Asphalt - bitumen with inert fill - 144 lb/ft3 - 3/4 in.,StandardOpaqueMaterial,VeryRough,0.75,8.0004,0.093745313,144,0.3,,,,,,,,,,,,,,,,,,,,, +Asphalt roll roofing - 1/4 in.,StandardOpaqueMaterial,VeryRough,0.25,1.6704,0.149664751,70,0.36,,,,,,,,,,,,,,,,,,,,, +Asphalt Shingles,StandardOpaqueMaterial,VeryRough,0.125984252,0.277338872,0.454261067,69.91931585,0.30094583,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Asphalt shingles - 1/4 in.,StandardOpaqueMaterial,VeryRough,0.25,0.5604,0.446109921,69.89,0.3,,,,,,,,,,,,,,,,,,,,, +AtticFloor Insulation,StandardOpaqueMaterial,MediumRough,9.366141732,0.339740118,27.56854794,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Birch - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,1.1904,0.840053763,43.93,0.39,,,,,,,,,,,,,,,,,,,,, +BLUE 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.48,0.05,0.05,0.57,0.06,0.06,0,0.84,0.84,1,FALSE,, +Brick - 48 lb/ft3 - 3 5/8 in.,StandardOpaqueMaterial,Rough,3.63,1.5,2.42,48,0.19,,,,,,,,,,,,,,,,,,,,, +Brick - fired clay - 140 lb/ft3 - 3 5/8 in.,StandardOpaqueMaterial,MediumRough,3.63,8.22,0.441605839,139.78,0.19,,,,,,,,,,,,,,,,,,,,, +BRONZE 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.482,0.054,0.054,0.534,0.057,0.057,0,0.84,0.84,1,FALSE,, +Building Paper - 1/16 in.,StandardOpaqueMaterial,MediumSmooth,0.06,2.0004,0.029994001,70,0.3,,,,,,,,,,,,,,,,,,,,, +Built-up Roofing,StandardOpaqueMaterial,Rough,0.374015748,1.109355488,0.337146886,69.91931585,0.348715009,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Built-up roofing - 3/8 in.,StandardOpaqueMaterial,VeryRough,0.38,1.14,0.333333333,70,0.35,,,,,,,,,,,,,,,,,,,,, +Built-up Roofing - Highly Reflective,StandardOpaqueMaterial,Rough,0.374015748,1.109355488,0.337146886,69.91931585,0.348715009,0.75,0.45,0.7,,,,,,,,,,,,,,,,,, +Bulk Storage Products Material,StandardOpaqueMaterial,Rough,96.0001946,9.998066642,9.601875846,12.49999184,0.199866248,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +California Redwood - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,0.78,1.282051282,26.21,0.39,,,,,,,,,,,,,,,,,,,,, +Carpet - 3/4 in.,StandardOpaqueMaterial,Rough,0.75,0.3156,2.376425856,18,0.33,,,,,,,,,,,,,,,,,,,,, +Carpet - 3/4 in. CBES,StandardOpaqueMaterial,Smooth,0.75,0.34691,,18,0.33,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +ceiling_2_Insulation,StandardOpaqueMaterial,Smooth,3.96766,0.15963,,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 1 1/2 in. R8.8,StandardOpaqueMaterial,Rough,1.5,0.1704,8.802816901,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 1 in. R5.9,StandardOpaqueMaterial,Rough,1,0.1704,5.868544601,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 1/2 in. R2.9,StandardOpaqueMaterial,Rough,0.5,0.1704,2.9342723,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 1/4 in. R1.5,StandardOpaqueMaterial,Rough,0.25,0.1704,1.46713615,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 1/8 in. R0.7,StandardOpaqueMaterial,Rough,0.13,0.1704,0.762910798,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 2 1/2 in. R15,StandardOpaqueMaterial,Rough,2.5,0.1704,14.6713615,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 2 in. R12,StandardOpaqueMaterial,Rough,2,0.1704,11.7370892,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 3 1/2 in. R21,StandardOpaqueMaterial,Rough,3.5,0.1704,20.5399061,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 3 in. R18,StandardOpaqueMaterial,Rough,3,0.1704,17.6056338,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 4 1/2 in. R26,StandardOpaqueMaterial,Rough,4.5,0.1704,26.4084507,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 4 in. R23,StandardOpaqueMaterial,Rough,4,0.1704,23.4741784,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 5 1/2 in. R32,StandardOpaqueMaterial,Rough,5.5,0.1704,32.27699531,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 5 in. R29,StandardOpaqueMaterial,Rough,5,0.1704,29.342723,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 6 1/2 in. R38,StandardOpaqueMaterial,Rough,6.5,0.1704,38.14553991,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Cellular polyisocyanurate (unfaced) - 6 in. R35,StandardOpaqueMaterial,Rough,6,0.1704,35.21126761,1.5,0.38,,,,,,,,,,,,,,,,,,,,, +Clay - Part Grouted and Empty - 130 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.12,1.923076923,130,0.13,,,,,,,,,,,,,,,,,,,,, +Clay - Part Grouted and Empty - 130 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,3.7596,2.127885945,130,0.13,,,,,,,,,,,,,,,,,,,,, +Clay - Part Grouted and Insulated - 130 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,2.7,2.222222222,130,0.13,,,,,,,,,,,,,,,,,,,,, +Clay - Part Grouted and Insulated - 130 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,3.12,2.564102564,130,0.13,,,,,,,,,,,,,,,,,,,,, +Clay - Solid Grout - 130 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.9,1.538461538,130,0.17,,,,,,,,,,,,,,,,,,,,, +Clay - Solid Grout - 130 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,4.56,1.754385965,130,0.17,,,,,,,,,,,,,,,,,,,,, +Clay tile - 1/2 in.,StandardOpaqueMaterial,MediumRough,0.5,0.1896,2.637130802,85,0.21,,,,,,,,,,,,,,,,,,,,, +Clay tile - hollow - 1 cell deep - 3 in.,StandardOpaqueMaterial,MediumRough,3,3.75,0.8,85,0.21,,,,,,,,,,,,,,,,,,,,, +Clay tile - hollow - 1 cell deep - 4 in.,StandardOpaqueMaterial,MediumRough,4,3.6,1.111111111,85,0.21,,,,,,,,,,,,,,,,,,,,, +Clay tile - hollow - 2 cells deep - 10 in.,StandardOpaqueMaterial,MediumRough,10,4.5,2.222222222,85,0.21,,,,,,,,,,,,,,,,,,,,, +Clay tile - hollow - 2 cells deep - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.9504,1.518833536,85,0.21,,,,,,,,,,,,,,,,,,,,, +Clay tile - hollow - 2 cells deep - 8 in.,StandardOpaqueMaterial,MediumRough,8,4.32,1.851851852,85,0.21,,,,,,,,,,,,,,,,,,,,, +Clay tile - hollow - 3 cells deep - 12 in.,StandardOpaqueMaterial,MediumRough,12,4.8,2.5,85,0.21,,,,,,,,,,,,,,,,,,,,, +Clay Tile - Paver,StandardOpaqueMaterial,MediumRough,0.38,12.504,0.030390275,139.78,0.22,,,,,,,,,,,,,,,,,,,,, +CLEAR 2.5MM,StandardGlazing,,0.098425197,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.8,0.075,0.075,0.901,0.081,0.081,0,0.84,0.84,1,FALSE,, +CLEAR 3MM,StandardGlazing,,0.118110236,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.837,0.075,0.075,0.898,0.081,0.081,0,0.84,0.84,1,FALSE,, +CLEAR 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.775,0.071,0.071,0.881,0.08,0.08,0,0.84,0.84,1,FALSE,, +COATED POLY-55,StandardGlazing,,0.02007874,0.970686052,1.030199206,,,,,,,,,,SpectralAverage,0.32,0.582,0.593,0.551,0.336,0.375,0,0.046,0.72,1,FALSE,, +COATED POLY-77,StandardGlazing,,0.02007874,0.970686052,1.030199206,,,,,,,,,,SpectralAverage,0.504,0.402,0.398,0.766,0.147,0.167,0,0.075,0.72,1,FALSE,, +Compliance Insulation R0.01,StandardOpaqueMaterial,MediumSmooth,0.0016,0.1596,0.010025063,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R0.02,StandardOpaqueMaterial,MediumSmooth,0.0032,0.1596,0.020050125,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R0.10,StandardOpaqueMaterial,MediumSmooth,0.016,0.1596,0.100250627,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R1.35,StandardOpaqueMaterial,MediumSmooth,0.216,0.1596,1.353383459,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R1.41,StandardOpaqueMaterial,MediumSmooth,0.2256,0.1596,1.413533835,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R1.54,StandardOpaqueMaterial,MediumSmooth,0.2464,0.1596,1.543859649,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R10.06,StandardOpaqueMaterial,MediumSmooth,1.6096,0.1596,10.08521303,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R12.55,StandardOpaqueMaterial,MediumSmooth,2.008,0.1596,12.58145363,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R12.69,StandardOpaqueMaterial,MediumSmooth,2.0304,0.1596,12.72180451,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R13.99,StandardOpaqueMaterial,MediumSmooth,2.2384,0.1596,14.02506266,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R14.14,StandardOpaqueMaterial,MediumSmooth,2.2624,0.1596,14.1754386,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R14.32,StandardOpaqueMaterial,MediumSmooth,2.2912,0.1596,14.35588972,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R14.60,StandardOpaqueMaterial,MediumSmooth,2.336,0.1596,14.63659148,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R15.54,StandardOpaqueMaterial,MediumSmooth,2.4864,0.1596,15.57894737,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R16.58,StandardOpaqueMaterial,MediumSmooth,2.6528,0.1596,16.62155388,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R16.69,StandardOpaqueMaterial,MediumSmooth,2.6704,0.1596,16.73182957,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R17.67,StandardOpaqueMaterial,MediumSmooth,2.8272,0.1596,17.71428571,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R19.63,StandardOpaqueMaterial,MediumSmooth,3.1408,0.1596,19.67919799,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R2.15,StandardOpaqueMaterial,MediumSmooth,0.344,0.1596,2.155388471,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R2.19,StandardOpaqueMaterial,MediumSmooth,0.3504,0.1596,2.195488722,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R2.85,StandardOpaqueMaterial,MediumSmooth,0.456,0.1596,2.857142857,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R2.89,StandardOpaqueMaterial,MediumSmooth,0.4624,0.1596,2.897243108,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R20.05,StandardOpaqueMaterial,MediumSmooth,3.208,0.1596,20.10025063,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R21.18,StandardOpaqueMaterial,MediumSmooth,3.3888,0.1596,21.23308271,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R21.39,StandardOpaqueMaterial,MediumSmooth,3.4224,0.1596,21.44360902,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R22.48,StandardOpaqueMaterial,MediumSmooth,3.5968,0.1596,22.53634085,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R24.86,StandardOpaqueMaterial,MediumSmooth,3.9776,0.1596,24.92230576,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R25.16,StandardOpaqueMaterial,MediumSmooth,4.0256,0.1596,25.22305764,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R28.63,StandardOpaqueMaterial,MediumSmooth,4.5808,0.1596,28.70175439,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R3.63,StandardOpaqueMaterial,MediumSmooth,0.5808,0.1596,3.639097744,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R3.70,StandardOpaqueMaterial,MediumSmooth,0.592,0.1596,3.709273183,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R34.93,StandardOpaqueMaterial,MediumSmooth,5.5888,0.1596,35.01754386,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R6.32,StandardOpaqueMaterial,MediumSmooth,1.0112,0.1596,6.335839599,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R6.46,StandardOpaqueMaterial,MediumSmooth,1.0336,0.1596,6.476190476,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R7.10,StandardOpaqueMaterial,MediumSmooth,1.136,0.1596,7.117794486,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R7.18,StandardOpaqueMaterial,MediumSmooth,1.1488,0.1596,7.197994987,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R7.39,StandardOpaqueMaterial,MediumSmooth,1.1824,0.1596,7.408521303,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R8.00,StandardOpaqueMaterial,MediumSmooth,1.28,0.1596,8.020050125,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R8.07,StandardOpaqueMaterial,MediumSmooth,1.2912,0.1596,8.090225564,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R9.83,StandardOpaqueMaterial,MediumSmooth,1.5697,0.1596,9.835213033,1,0.27,,,,,,,,,,,,,,,,,,,,, +Compliance Insulation R9.94,StandardOpaqueMaterial,MediumSmooth,1.5904,0.1596,9.964912281,1,0.27,,,,,,,,,,,,,,,,,,,,, +Concrete - 100 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,6.2496,1.600102407,100,0.21,,,,,,,,,,,,,,,,,,,,, +Concrete - 100 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,6.2496,1.920122888,100,0.21,,,,,,,,,,,,,,,,,,,,, +Concrete - 100 lb/ft3 - 2 in.,StandardOpaqueMaterial,MediumRough,2,6.2496,0.320020481,100,0.21,,,,,,,,,,,,,,,,,,,,, +Concrete - 100 lb/ft3 - 4 in.,StandardOpaqueMaterial,MediumRough,4,6.2496,0.640040963,100,0.21,,,,,,,,,,,,,,,,,,,,, +Concrete - 100 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,6.2496,0.960061444,100,0.21,,,,,,,,,,,,,,,,,,,,, +Concrete - 100 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,6.2496,1.280081925,100,0.21,,,,,,,,,,,,,,,,,,,,, +Concrete - 140 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,13.53,0.7390983,139.78,0.22,,,,,,,,,,,,,,,,,,,,, +Concrete - 140 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,13.53,0.88691796,139.78,0.22,,,,,,,,,,,,,,,,,,,,, +Concrete - 140 lb/ft3 - 2 in.,StandardOpaqueMaterial,MediumRough,2,13.53,0.14781966,139.78,0.22,,,,,,,,,,,,,,,,,,,,, +Concrete - 140 lb/ft3 - 4 in.,StandardOpaqueMaterial,MediumRough,4,13.53,0.29563932,139.78,0.22,,,,,,,,,,,,,,,,,,,,, +Concrete - 140 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,13.53,0.44345898,139.78,0.22,,,,,,,,,,,,,,,,,,,,, +Concrete - 140 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,13.53,0.59127864,139.78,0.22,,,,,,,,,,,,,,,,,,,,, +Concrete - 80 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,3.6804,2.717095968,79.87,0.2,,,,,,,,,,,,,,,,,,,,, +Concrete - 80 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,3.6804,3.260515161,79.87,0.2,,,,,,,,,,,,,,,,,,,,, +Concrete - 80 lb/ft3 - 2 in.,StandardOpaqueMaterial,MediumRough,2,3.6804,0.543419194,79.87,0.2,,,,,,,,,,,,,,,,,,,,, +Concrete - 80 lb/ft3 - 4 in.,StandardOpaqueMaterial,MediumRough,4,3.6804,1.086838387,79.87,0.2,,,,,,,,,,,,,,,,,,,,, +Concrete - 80 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.6804,1.630257581,79.87,0.2,,,,,,,,,,,,,,,,,,,,, +Concrete - 80 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,3.6804,2.173676774,79.87,0.2,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Empty - 105 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,4.5996,2.174102096,105,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Empty - 105 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,5.16,2.325581395,105,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Empty - 105 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.24,1.851851852,105,0.15,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Empty - 105 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,3.9996,2.00020002,105,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Empty - 115 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,4.8996,2.040982937,115,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Empty - 115 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,5.52,2.173913043,115,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Empty - 115 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.48,1.724137931,115,0.15,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Empty - 115 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,4.2396,1.886970469,115,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Empty - 125 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,5.1996,1.923224863,125,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Empty - 125 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,5.88,2.040816327,125,0.13,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Empty - 125 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.66,1.639344262,125,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Empty - 125 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,4.4796,1.785873739,125,0.13,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Insulated - 105 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,3.3996,2.941522532,105,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Insulated - 105 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,3.6,3.333333333,105,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Insulated - 105 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,2.64,2.272727273,105,0.15,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Insulated - 105 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,2.9604,2.702337522,105,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Insulated - 115 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,3.6996,2.702994918,115,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Insulated - 115 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,3.96,3.03030303,115,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Insulated - 115 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,2.88,2.083333333,115,0.15,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Insulated - 115 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,3.2796,2.439321869,115,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Insulated - 125 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,4.1004,2.43878646,125,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Insulated - 125 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,4.32,2.777777778,125,0.13,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Insulated - 125 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.12,1.923076923,125,0.14,,,,,,,,,,,,,,,,,,,,, +Concrete - Part Grouted and Insulated - 125 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,3.5196,2.272985567,125,0.13,,,,,,,,,,,,,,,,,,,,, +Concrete - Solid Grout - 105 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,8.4744,1.180024545,105,0.22,,,,,,,,,,,,,,,,,,,,, +Concrete - Solid Grout - 105 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,8.5704,1.40016802,105,0.22,,,,,,,,,,,,,,,,,,,,, +Concrete - Solid Grout - 105 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,8.3328,0.720046083,105,0.21,,,,,,,,,,,,,,,,,,,,, +Concrete - Solid Grout - 105 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,8.3328,0.960061444,105,0.22,,,,,,,,,,,,,,,,,,,,, +Concrete - Solid Grout - 115 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,9.174,1.090037061,115,0.21,,,,,,,,,,,,,,,,,,,,, +Concrete - Solid Grout - 115 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,9.2304,1.300052002,115,0.21,,,,,,,,,,,,,,,,,,,,, +Concrete - Solid Grout - 115 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,10.17,0.589970501,115,0.2,,,,,,,,,,,,,,,,,,,,, +Concrete - Solid Grout - 115 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,9.1224,0.876962203,115,0.2,,,,,,,,,,,,,,,,,,,,, +Concrete - Solid Grout - 125 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,10.1016,0.989942187,125,0.2,,,,,,,,,,,,,,,,,,,,, +Concrete - Solid Grout - 125 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,10.0836,1.190051172,125,0.2,,,,,,,,,,,,,,,,,,,,, +Concrete - Solid Grout - 125 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,10.17,0.589970501,125,0.19,,,,,,,,,,,,,,,,,,,,, +Concrete - Solid Grout - 125 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,10.1268,0.789983015,125,0.2,,,,,,,,,,,,,,,,,,,,, +Concrete Paver,StandardOpaqueMaterial,MediumRough,0.38,4.5024,0.084399431,144,0.2,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 100% Ins. Layer - No Steel in Ins. - Ins. 1 1/2 in.,StandardOpaqueMaterial,MediumRough,13.5,1.8396,7.338551859,133.44,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 100% Ins. Layer - No Steel in Ins. - Ins. 2 in.,StandardOpaqueMaterial,MediumRough,14,1.4496,9.657836645,128.71,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 100% Ins. Layer - No Steel in Ins. - Ins. 3 in.,StandardOpaqueMaterial,MediumRough,15,1.05,14.28571429,120.2,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 100% Ins. Layer - No Steel in Ins. - Ins. 4 in.,StandardOpaqueMaterial,MediumRough,16,0.8496,18.83239171,112.75,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 100% Ins. Layer - No Steel in Ins. - Ins. 6 in.,StandardOpaqueMaterial,MediumRough,18,0.63,28.57142857,100.33,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 100% Ins. Layer - Steel in Ins. - Ins. 1 1/2 in.,StandardOpaqueMaterial,MediumRough,13.5,2.5704,5.25210084,133.44,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 100% Ins. Layer - Steel in Ins. - Ins. 2 in.,StandardOpaqueMaterial,MediumRough,14,2.01,6.965174129,128.71,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 100% Ins. Layer - Steel in Ins. - Ins. 3 in.,StandardOpaqueMaterial,MediumRough,15,1.4796,10.1378751,120.2,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 100% Ins. Layer - Steel in Ins. - Ins. 4 in.,StandardOpaqueMaterial,MediumRough,16,1.1904,13.44086022,112.75,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 100% Ins. Layer - Steel in Ins. - Ins. 6 in.,StandardOpaqueMaterial,MediumRough,18,0.9,20,100.33,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 80% Ins. Layer - No Steel in Ins. - Ins. 1 1/2 in.,StandardOpaqueMaterial,MediumRough,13.5,15.8604,0.851176515,133.44,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 80% Ins. Layer - No Steel in Ins. - Ins. 2 in.,StandardOpaqueMaterial,MediumRough,14,14.7504,0.949126803,128.71,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 80% Ins. Layer - No Steel in Ins. - Ins. 3 in.,StandardOpaqueMaterial,MediumRough,15,11.9904,1.251000801,120.2,0.12,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 80% Ins. Layer - No Steel in Ins. - Ins. 4 in.,StandardOpaqueMaterial,MediumRough,16,10.3404,1.547328923,112.75,0.12,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 80% Ins. Layer - No Steel in Ins. - Ins. 6 in.,StandardOpaqueMaterial,MediumRough,18,8.3604,2.153007033,100.33,0.13,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 80% Ins. Layer - Steel in Ins. - Ins. 1 1/2 in.,StandardOpaqueMaterial,MediumRough,13.5,15.8604,0.851176515,133.44,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 80% Ins. Layer - Steel in Ins. - Ins. 2 in.,StandardOpaqueMaterial,MediumRough,14,25.1796,0.556005655,128.71,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 80% Ins. Layer - Steel in Ins. - Ins. 3 in.,StandardOpaqueMaterial,MediumRough,15,31.5096,0.476045396,120.2,0.12,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 80% Ins. Layer - Steel in Ins. - Ins. 4 in.,StandardOpaqueMaterial,MediumRough,16,38.37,0.416992442,112.75,0.12,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 80% Ins. Layer - Steel in Ins. - Ins. 6 in.,StandardOpaqueMaterial,MediumRough,18,54.0504,0.333022512,100.33,0.13,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 90% Ins. Layer - No Steel in Ins. - Ins. 1 1/2 in.,StandardOpaqueMaterial,MediumRough,13.5,10.7904,1.2511121,133.44,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 90% Ins. Layer - No Steel in Ins. - Ins. 2 in.,StandardOpaqueMaterial,MediumRough,14,9.66,1.449275362,128.71,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 90% Ins. Layer - No Steel in Ins. - Ins. 3 in.,StandardOpaqueMaterial,MediumRough,15,7.32,2.049180328,120.2,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 90% Ins. Layer - No Steel in Ins. - Ins. 4 in.,StandardOpaqueMaterial,MediumRough,16,6.0396,2.649182065,112.75,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 90% Ins. Layer - No Steel in Ins. - Ins. 6 in.,StandardOpaqueMaterial,MediumRough,18,4.7904,3.75751503,100.33,0.12,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 90% Ins. Layer - Steel in Ins. - Ins. 1 1/2 in.,StandardOpaqueMaterial,MediumRough,13.5,11.7396,1.149954002,133.44,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 90% Ins. Layer - Steel in Ins. - Ins. 2 in.,StandardOpaqueMaterial,MediumRough,14,9.66,1.449275362,128.71,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 90% Ins. Layer - Steel in Ins. - Ins. 3 in.,StandardOpaqueMaterial,MediumRough,15,7.6896,1.950686642,120.2,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 90% Ins. Layer - Steel in Ins. - Ins. 4 in.,StandardOpaqueMaterial,MediumRough,16,6.5304,2.450079628,112.75,0.11,,,,,,,,,,,,,,,,,,,,, +Concrete Sandwich Panel - 90% Ins. Layer - Steel in Ins. - Ins. 6 in.,StandardOpaqueMaterial,MediumRough,18,5.0604,3.557031065,100.33,0.12,,,,,,,,,,,,,,,,,,,,, +Concrete/Sand Aggregate - 6 in.,StandardOpaqueMaterial,Smooth,6.01,4.29,1.400932401,116,0.2,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Double glass with no low e coatings - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.9,2.522222222,29.09,0.26,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Double glass with no low e coatings - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.26196,12.4828218,20.44,0.26,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Double glass with no low e coatings - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.25296,17.67077799,15.23,0.27,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Double glass with no low e coatings - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,0.25308,22.40398293,12.22,0.27,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Double glass with no low e coatings - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,0.2478,27.72397094,10.26,0.27,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Double glass with no low e coatings - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,0.2484,32.48792271,8.88,0.27,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Double glass with no low e coatings - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.2814,6.503198294,35.69,0.26,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Double glass with no low e coatings - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.27,9.444444444,25.92,0.26,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Single glass pane. stone. or metal pane - No Ins.,StandardOpaqueMaterial,Smooth,2.27,1.1796,1.924381146,29.09,0.26,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Single glass pane. stone. or metal pane - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.27312,11.97275923,20.44,0.26,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Single glass pane. stone. or metal pane - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.2628,17.00913242,15.23,0.27,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Single glass pane. stone. or metal pane - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,0.2592,21.875,12.22,0.27,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Single glass pane. stone. or metal pane - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,0.25512,26.92850423,10.26,0.27,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Single glass pane. stone. or metal pane - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,0.25692,31.41055582,8.88,0.27,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Single glass pane. stone. or metal pane - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.3096,5.910852713,35.69,0.26,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Single glass pane. stone. or metal pane - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.28476,8.954909397,25.92,0.26,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Triple or low e glass - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.78,2.91025641,29.09,0.26,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Triple or low e glass - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.25452,12.84771334,20.44,0.26,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Triple or low e glass - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.24804,18.02128689,15.23,0.27,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Triple or low e glass - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,0.24696,22.95918367,12.22,0.27,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Triple or low e glass - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,0.2478,27.72397094,10.26,0.27,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Triple or low e glass - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,0.2484,32.48792271,8.88,0.27,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Triple or low e glass - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.2652,6.900452489,35.69,0.26,,,,,,,,,,,,,,,,,,,,, +Continuous Ins. - Triple or low e glass - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.25752,9.902143523,25.92,0.26,,,,,,,,,,,,,,,,,,,,, +CP02 CARPET PAD,MasslessOpaqueMaterial,VeryRough,,,1.229230374,,,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +Douglas Fir-Larch - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,0.9804,1.01999184,34.88,0.39,,,,,,,,,,,,,,,,,,,,, +ECABS-2 BLEACHED 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.814,0.086,0.086,0.847,0.099,0.099,0,0.84,0.1,1,FALSE,, +ECABS-2 COLORED 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.111,0.179,0.179,0.128,0.081,0.081,0,0.84,0.1,1,FALSE,, +ECREF-1 COLORED 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.099,0.219,0.219,0.155,0.073,0.073,0,0.84,0.84,1,FALSE,, +ECREF-2 BLEACHED 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.694,0.168,0.168,0.818,0.11,0.11,0,0.84,0.1,1,FALSE,, +ECREF-2 COLORED 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.099,0.219,0.219,0.155,0.073,0.073,0,0.84,0.1,1,FALSE,, +Expanded perlite - organic bonded - 1 1/2 in. R4.2,StandardOpaqueMaterial,MediumSmooth,1.5,0.36,4.166666667,1,0.3,,,,,,,,,,,,,,,,,,,,, +Expanded perlite - organic bonded - 1 in. R2.8,StandardOpaqueMaterial,MediumSmooth,1,0.36,2.777777778,1,0.3,,,,,,,,,,,,,,,,,,,,, +Expanded perlite - organic bonded - 2 in. R5.6,StandardOpaqueMaterial,MediumSmooth,2,0.36,5.555555556,1,0.3,,,,,,,,,,,,,,,,,,,,, +Expanded perlite - organic bonded - 3 in. R8.3,StandardOpaqueMaterial,MediumSmooth,3,0.36,8.333333333,1,0.3,,,,,,,,,,,,,,,,,,,,, +Expanded perlite - organic bonded - 3/4 in. R2.1,StandardOpaqueMaterial,MediumSmooth,0.75,0.36,2.083333333,1,0.3,,,,,,,,,,,,,,,,,,,,, +Expanded perlite - organic bonded - 4 in. R11,StandardOpaqueMaterial,MediumSmooth,4,0.36,11.11111111,1,0.3,,,,,,,,,,,,,,,,,,,,, +Expanded perlite - organic bonded - 6 in. R17,StandardOpaqueMaterial,MediumSmooth,6,0.36,16.66666667,1,0.3,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 1 1/2 in. R6.3,StandardOpaqueMaterial,MediumSmooth,1.5,0.24,6.25,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 1 1/4 in. R5.2,StandardOpaqueMaterial,MediumSmooth,1.25,0.24,5.208333333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 1 15/16 in. R8.1,StandardOpaqueMaterial,MediumSmooth,1.94,0.24,8.083333333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 1 3/4 in. R7.3,StandardOpaqueMaterial,MediumSmooth,1.75,0.24,7.291666667,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 1 7/8 in. R8.0,StandardOpaqueMaterial,MediumSmooth,1.92,0.24,8,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 1 in. R4.2,StandardOpaqueMaterial,MediumSmooth,1,0.24,4.166666667,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 1/2 in. R2.1,StandardOpaqueMaterial,MediumSmooth,0.5,0.24,2.083333333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 1/4 in. R1.0,StandardOpaqueMaterial,MediumSmooth,0.25,0.24,1.041666667,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 2 2/5 in. R10,StandardOpaqueMaterial,MediumSmooth,2.4,0.24,10,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 2 7/16 in. R10,StandardOpaqueMaterial,MediumSmooth,2.43,0.24,10.125,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 2 in. R8.3,StandardOpaqueMaterial,MediumSmooth,2,0.24,8.333333333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 3 1/2 in. R15,StandardOpaqueMaterial,MediumSmooth,3.5,0.24,14.58333333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 3 1/3 in. R14,StandardOpaqueMaterial,MediumSmooth,3.35,0.24,13.95833333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 3 2/5 in. R14,StandardOpaqueMaterial,MediumSmooth,3.39,0.24,14.125,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 3 in. R13,StandardOpaqueMaterial,MediumSmooth,3.01,0.24,12.54166667,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 3/4 in. R3.1,StandardOpaqueMaterial,MediumSmooth,0.75,0.24,3.125,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 4 1/16 in. R17,StandardOpaqueMaterial,MediumSmooth,4.05,0.24,16.875,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 4 7/10 in. R20,StandardOpaqueMaterial,MediumSmooth,4.71,0.24,19.625,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 5 19/20 in. R25,StandardOpaqueMaterial,MediumSmooth,5.96,0.24,24.83333333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 5 2/5 in. R22,StandardOpaqueMaterial,MediumSmooth,5.2,0.24,21.66666667,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 6 1/10 in. R25,StandardOpaqueMaterial,MediumSmooth,6.11,0.24,25.45833333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 6 7/8 in. R29,StandardOpaqueMaterial,MediumSmooth,6.87,0.24,28.625,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polystyrene - EPS - 8 3/5 in. R35,StandardOpaqueMaterial,MediumSmooth,8.38,0.24,34.91666667,1.2,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polyurethane - 1 1/4 in. R7.8,StandardOpaqueMaterial,MediumSmooth,1.25,0.1596,7.832080201,1,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polyurethane - 1 in. R6.3,StandardOpaqueMaterial,MediumSmooth,1,0.1596,6.26566416,1,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polyurethane - 1/2 in. R3.1,StandardOpaqueMaterial,MediumSmooth,0.5,0.1596,3.13283208,1,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polyurethane - 2 in. R12.6,StandardOpaqueMaterial,MediumSmooth,2,0.1596,12.53132832,1,0.27,,,,,,,,,,,,,,,,,,,,, +Expanded Polyurethane - 3/4 in. R4.7,StandardOpaqueMaterial,MediumSmooth,0.75,0.1596,4.69924812,1,0.27,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 1 1/2 in. R7.50,StandardOpaqueMaterial,MediumSmooth,1.5,0.200000004,7.49999985,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 1 1/4 in. R6.25,StandardOpaqueMaterial,MediumSmooth,1.25,0.200000004,6.249999875,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 1 3/4 in. R8.75,StandardOpaqueMaterial,MediumSmooth,1.75,0.200000004,8.749999825,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 1 7/8 in. R9.37,StandardOpaqueMaterial,MediumSmooth,1.88,0.200000004,9.399999812,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 1 in. R5.00,StandardOpaqueMaterial,MediumSmooth,1,0.200000004,4.9999999,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 1/2 in. R2.50,StandardOpaqueMaterial,MediumSmooth,0.5,0.200000004,2.49999995,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 1/4 in. R1.25,StandardOpaqueMaterial,MediumSmooth,0.25,0.200000004,1.249999975,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 2 1/2 in. R12.50,StandardOpaqueMaterial,MediumSmooth,2.5,0.200000004,12.49999975,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 2 in. R10.00,StandardOpaqueMaterial,MediumSmooth,2,0.200000004,9.9999998,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 3 1/2 in. R17.50,StandardOpaqueMaterial,MediumSmooth,3.5,0.200000004,17.49999965,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 3 in. R15.00,StandardOpaqueMaterial,MediumSmooth,3,0.200000004,14.9999997,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 3/4 in. R3.75,StandardOpaqueMaterial,MediumSmooth,0.75,0.200000004,3.749999925,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 4 1/2 in. R22.50,StandardOpaqueMaterial,MediumSmooth,4.5,0.200000004,22.49999955,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 4 in. R20.00,StandardOpaqueMaterial,MediumSmooth,4,0.200000004,19.9999996,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 5 1/2 in. R27.50,StandardOpaqueMaterial,MediumSmooth,5.5,0.200000004,27.49999945,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 5 in. R25.00,StandardOpaqueMaterial,MediumSmooth,5,0.200000004,24.9999995,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 6 1/2 in. R32.50,StandardOpaqueMaterial,MediumSmooth,6.5,0.200000004,32.49999935,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 6 in. R30.00,StandardOpaqueMaterial,MediumSmooth,6,0.200000004,29.9999994,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 8 1/2 in. R42.50,StandardOpaqueMaterial,MediumSmooth,8.5,0.200000004,42.49999915,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +Extruded Polystyrene - XPS - 8 in. R40.00,StandardOpaqueMaterial,MediumSmooth,8,0.200000004,39.9999992,1.3,0.35,,,,,,,,,,,,,,,,,,,,, +F04 Wall air space resistance,AirGap,,,46.22314532,0.021634183,,,,,,,,,,,,,,,,,,,,,,, +F05 Ceiling air space resistance,AirGap,,,38.51928777,0.02596102,,,,,,,,,,,,,,,,,,,,,,, +F08 Metal surface,StandardOpaqueMaterial,Smooth,0.031496063,313.947603,0.000100323,488.4363635,0.119422948,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +F16 Acoustic tile,StandardOpaqueMaterial,MediumSmooth,0.751968504,0.416008308,1.807580497,22.97348949,0.140919079,0.9,0.3,0.3,,,,,,,,,,,,,,,,,, +Fiber cement board - 63 lb/ft3 - 1/3 in.,StandardOpaqueMaterial,Smooth,0.31,1.2996,0.238534934,63,0.2,,,,,,,,,,,,,,,,,,,,, +Fiber cement board - 88 lb/ft3 - 1/2 in.,StandardOpaqueMaterial,Smooth,0.47,1.7004,0.276405552,88,0.2,,,,,,,,,,,,,,,,,,,,, +Fiber cement board - 88 lb/ft3 - 1/3 in.,StandardOpaqueMaterial,Smooth,0.31,1.7004,0.182310045,88,0.2,,,,,,,,,,,,,,,,,,,,, +Fiberboard sheathing - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.4896,1.02124183,24.96,0.31,,,,,,,,,,,,,,,,,,,,, +Fixed Window 2.00/0.40/0.31,SimpleGlazing,,,,,,,,,,,0.35,0.4,0.31,,,,,,,,,,,,,, +Fixed Window 2.00/0.45/0.35,SimpleGlazing,,,,,,,,,,,0.35,0.45,0.35,,,,,,,,,,,,,, +Fixed Window 2.30/0.40/0.31,SimpleGlazing,,,,,,,,,,,0.4,0.4,0.31,,,,,,,,,,,,,, +Fixed Window 2.56/0.45/0.35,SimpleGlazing,,,,,,,,,,,0.45,0.45,0.35,,,,,,,,,,,,,, +Fixed Window 2.62/0.30/0.21,SimpleGlazing,,,,,,,,,,,0.459978667,0.3,0.21,,,,,,,,,,,,,, +Fixed Window 2.67/0.30/0.21,SimpleGlazing,,,,,,,,,,,0.469978203,0.49,0.38,,,,,,,,,,,,,, +Fixed Window 2.96/0.39/0.31,SimpleGlazing,,,,,,,,,,,0.519975884,0.39,0.31,,,,,,,,,,,,,, +Fixed Window 2.96/0.49/0.41,SimpleGlazing,,,,,,,,,,,0.519975884,0.49,0.41,,,,,,,,,,,,,, +Fixed Window 2.96/0.62/0.54,SimpleGlazing,,,,,,,,,,,0.519975884,0.62,0.54,,,,,,,,,,,,,, +Fixed Window 3.12/0.40/0.31,SimpleGlazing,,,,,,,,,,,0.55,0.4,0.31,,,,,,,,,,,,,, +Fixed Window 3.24/0.25/0.16,SimpleGlazing,,,,,,,,,,,0.569973565,0.25,0.16,,,,,,,,,,,,,, +Fixed Window 3.24/0.39/0.31,SimpleGlazing,,,,,,,,,,,0.569973565,0.39,0.31,,,,,,,,,,,,,, +Fixed Window 3.24/0.49/0.41,SimpleGlazing,,,,,,,,,,,0.569973565,0.49,0.41,,,,,,,,,,,,,, +Fixed Window 3.35/0.36/0.27,SimpleGlazing,,,,,,,,,,,0.589972638,0.36,0.27,,,,,,,,,,,,,, +Fixed Window 3.35/0.39/0.31,SimpleGlazing,,,,,,,,,,,0.589972638,0.39,0.31,,,,,,,,,,,,,, +Fixed Window 3.53/0.41/0.32,SimpleGlazing,,,,,,,,,,,0.619971246,0.41,0.32,,,,,,,,,,,,,, +Fixed Window 3.69/0.25/0.16,SimpleGlazing,,,,,,,,,,,0.65,0.25,0.16,,,,,,,,,,,,,, +Fixed Window 3.69/0.70/0.60,SimpleGlazing,,,,,,,,,,,0.65,0.7,0.6,,,,,,,,,,,,,, +Fixed Window 3.81/0.39/0.27,SimpleGlazing,,,,,,,,,,,0.519975884,0.39,0.27,,,,,,,,,,,,,, +Fixed Window 3.81/0.49/0.38,SimpleGlazing,,,,,,,,,,,0.519975884,0.49,0.38,,,,,,,,,,,,,, +Fixed Window 4.09/0.26/0.13,SimpleGlazing,,,,,,,,,,,0.719966609,0.25,0.13,,,,,,,,,,,,,, +Fixed Window 4.09/0.36/0.23,SimpleGlazing,,,,,,,,,,,0.719966609,0.36,0.23,,,,,,,,,,,,,, +Fixed Window 4.09/0.39/0.25,SimpleGlazing,,,,,,,,,,,0.719966609,0.39,0.25,,,,,,,,,,,,,, +Fixed Window 4.26/0.25/0.16,SimpleGlazing,,,,,,,,,,,0.75,0.25,0.16,,,,,,,,,,,,,, +Fixed Window 5.84/0.25/0.11,SimpleGlazing,,,,,,,,,,,1.028483473,0.25,0.11,,,,,,,,,,,,,, +Fixed Window 5.84/0.39/0.22,SimpleGlazing,,,,,,,,,,,1.028483473,0.39,0.22,,,,,,,,,,,,,, +Fixed Window 5.84/0.44/0.27,SimpleGlazing,,,,,,,,,,,1.028483473,0.44,0.27,,,,,,,,,,,,,, +Fixed Window 5.84/0.54/0.38,SimpleGlazing,,,,,,,,,,,1.028483473,0.54,0.38,,,,,,,,,,,,,, +Fixed Window 5.84/0.61/0.47,SimpleGlazing,,,,,,,,,,,1.028483473,0.61,0.47,,,,,,,,,,,,,, +Fixed Window 5.84/0.70/0.60,SimpleGlazing,,,,,,,,,,,1.028483473,0.7,0.6,,,,,,,,,,,,,, +G01 13mm gypsum board,StandardOpaqueMaterial,Smooth,0.5,1.10957004,0.450625001,49.9424,0.260516252,0.9,0.7,0.5,,,,,,,,,,,,,,,,,, +G01a 19mm gypsum board,StandardOpaqueMaterial,MediumSmooth,0.748031496,1.109355488,0.674293772,49.94236846,0.260342027,0.9,0.4,0.4,,,,,,,,,,,,,,,,,, +G05 25mm wood,StandardOpaqueMaterial,MediumSmooth,1,1.04002077,0.961519259,37.95620003,0.389318812,0.9,0.5,0.5,,,,,,,,,,,,,,,,,, +Gap_1_W_0_0018,Gas,,0.070866142,,,,,,,,Air,,,,,,,,,,,,,,,,, +Gap_1_W_0_0024,Gas,,0.094488189,,,,,,,,Air,,,,,,,,,,,,,,,,, +Gap_1_W_0_0025,Gas,,0.098425197,,,,,,,,Air,,,,,,,,,,,,,,,,, +Gap_1_W_0_0032,Gas,,0.125984252,,,,,,,,Air,,,,,,,,,,,,,,,,, +Gap_1_W_0_0038,Gas,,0.149606299,,,,,,,,Air,,,,,,,,,,,,,,,,, +Gap_1_W_0_0042,Gas,,0.165354331,,,,,,,,Air,,,,,,,,,,,,,,,,, +Gap_1_W_0_0043,Gas,,0.169291339,,,,,,,,Air,,,,,,,,,,,,,,,,, +Glass fiber batt - 10 in. R30 (CEC Default),StandardOpaqueMaterial,MediumRough,10,0.3336,29.97601918,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass fiber batt - 12 in. R38 (CEC Default),StandardOpaqueMaterial,MediumRough,12,0.3156,38.02281369,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass fiber batt - 3 1/2 in. R11 (CEC Default),StandardOpaqueMaterial,MediumRough,3.5,0.318,11.00628931,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass fiber batt - 3 1/2 in. R13 (CEC Default),StandardOpaqueMaterial,MediumRough,3.5,0.2688,13.02083333,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass fiber batt - 3 1/2 in. R15 (CEC Default),StandardOpaqueMaterial,MediumRough,3.5,0.2328,15.03436426,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass fiber batt - 4 1/2 in.,StandardOpaqueMaterial,MediumRough,4.5,0.3,15,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass fiber batt - 4 in.,StandardOpaqueMaterial,MediumRough,4,0.3,13.33333333,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass fiber batt - 5 1/2 in. R19 (CEC Default),StandardOpaqueMaterial,MediumRough,5.5,0.306,17.97385621,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass fiber batt - 5 1/2 in. R21 (CEC Default),StandardOpaqueMaterial,MediumRough,5.5,0.2616,21.02446483,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass fiber batt - 5 in.,StandardOpaqueMaterial,MediumRough,5,0.3,16.66666667,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass fiber batt - 6 1/2 in.,StandardOpaqueMaterial,MediumRough,6.5,0.3,21.66666667,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass fiber batt - 6 in.,StandardOpaqueMaterial,MediumRough,6,0.3,20,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass fiber batt - 7 1/4 in. R25 (CEC Default),StandardOpaqueMaterial,MediumRough,7.25,0.3024,23.97486772,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass fiber batt - 7 1/4 in. R30 (CEC Default),StandardOpaqueMaterial,MediumRough,7.25,0.2904,24.96556474,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass fiber batt - 8 1/4 in. R30C (CEC Default),StandardOpaqueMaterial,MediumRough,8.25,0.2748,30.02183406,0.7,0.2,,,,,,,,,,,,,,,,,,,,, +Glass_2010F_LayerAvg,StandardGlazing,,0.087007874,6.933471799,0.144227889,,,,,,,,,,SpectralAverage,0.434294,0.4183747,0.3410654,0.797579,0.043577,0.056031,0,0.042274,0.84,1,FALSE,, +Glass_2022F_LayerAvg,StandardGlazing,,0.153543307,6.933471799,0.144227889,,,,,,,,,,SpectralAverage,0.355897,0.3940945,0.2656452,0.677694,0.042734,0.05547,0,0.046,0.84,1,FALSE,, +Glass_2027F_LayerAvg,StandardGlazing,,0.157480315,6.933471799,,,,,,,,,,,SpectralAverage,0.369744,0.4700695,0.340935,0.765222,0.0546,0.073741,0,0.03675,0.84,1,FALSE,, +Glass_2052_LayerAvg,StandardGlazing,,0.329527559,6.933471799,,,,,,,,,,,SpectralAverage,0.507767,0.05422805,0.05449309,0.586833,0.05805,0.058397,0,0.84,0.84,1,FALSE,, +Glass_2175_LayerAvg,StandardGlazing,,0.338582677,6.933471799,0.144227889,,,,,,,,,,SpectralAverage,0.167758,0.2176064,0.4379779,0.416044,0.078729,0.10654,0,0.84,0.84,1,FALSE,, +GREEN 3MM,StandardGlazing,,0.118110236,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.635,0.063,0.063,0.822,0.075,0.075,0,0.84,0.84,1,FALSE,, +GREEN 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.487,0.056,0.056,0.749,0.07,0.07,0,0.84,0.84,1,FALSE,, +GREY 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.455,0.053,0.053,0.431,0.052,0.052,0,0.84,0.84,1,FALSE,, +Ground_Floor_R11_T2013,StandardOpaqueMaterial,Smooth,1.74123,0.15963,10.91,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +Ground_Floor_R17_T2013,StandardOpaqueMaterial,Smooth,2.71324,0.15963,17.66,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +Ground_Floor_R22_T2013,StandardOpaqueMaterial,Smooth,3.51125,0.15963,22.47,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +Gypsum Board - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,1.10004,0.454528926,40,0.27,,,,,,,,,,,,,,,,,,,,, +Gypsum Board - 1/2 in. CBES,StandardOpaqueMaterial,Smooth,0.5,1.1101,,40,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +Gypsum Board - 3/4 in.,StandardOpaqueMaterial,MediumSmooth,0.75,1.10004,0.681793389,40,0.27,,,,,,,,,,,,,,,,,,,,, +Gypsum Board - 3/8 in.,StandardOpaqueMaterial,MediumSmooth,0.38,1.10004,0.345441984,40,0.27,,,,,,,,,,,,,,,,,,,,, +Gypsum Board - 5/8 in.,StandardOpaqueMaterial,MediumSmooth,0.63,1.10004,0.572706447,40,0.27,,,,,,,,,,,,,,,,,,,,, +Gypsum Or Plaster Board - 3/8 in.,StandardOpaqueMaterial,MediumSmooth,0.374015748,4.021413643,0.093006037,49.94236846,0.260342027,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Gypsum partition block - 3 cells - 4 in. x 12 in. x 30 in. - 4 in.,StandardOpaqueMaterial,MediumRough,4,2.4,1.666666667,53.1,0.19,,,,,,,,,,,,,,,,,,,,, +Gypsum partition block - 4 cells - 3 in. x 12 in. x 30 in. - 3 in.,StandardOpaqueMaterial,MediumRough,3,2.22,1.351351351,53.1,0.19,,,,,,,,,,,,,,,,,,,,, +Gypsum partition block - solid - 3 in. x 12 in. x 30 in. - 3 in.,StandardOpaqueMaterial,MediumRough,3,2.3796,1.260716087,62.4,0.19,,,,,,,,,,,,,,,,,,,,, +Gypsum plaster - 80 lb/ft3 - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,3.2004,0.156230471,80,0.26,,,,,,,,,,,,,,,,,,,,, +Gypsum plaster - 80 lb/ft3 - 5/8 in.,StandardOpaqueMaterial,Smooth,0.63,3.2004,0.196850394,80,0.26,,,,,,,,,,,,,,,,,,,,, +Gypsum plaster - on metal lath 70 lb/ft3 - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,2.6004,0.288417167,70,0.26,,,,,,,,,,,,,,,,,,,,, +Gypsum plaster - on metal lath 80 lb/ft3 - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,3.2004,0.234345707,80,0.26,,,,,,,,,,,,,,,,,,,,, +Hard Board - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,0.72,1.041666667,50,0.31,,,,,,,,,,,,,,,,,,,,, +Hardboard - HDF - 50 lb/ft3 - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.7296,0.685307018,50,0.31,,,,,,,,,,,,,,,,,,,,, +Hardboard - HDF - 50 lb/ft3 - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,0.7296,1.027960526,50,0.31,,,,,,,,,,,,,,,,,,,,, +Hardboard - HDF - 50 lb/ft3 - 3/8 in.,StandardOpaqueMaterial,Smooth,0.38,0.7296,0.520833333,50,0.31,,,,,,,,,,,,,,,,,,,,, +Hardboard - HDF - 50 lb/ft3 - 5/8 in.,StandardOpaqueMaterial,Smooth,6.30E-01,0.7296,8.63E-01,50,0.31,,,,,,,,,,,,,,,,,,,,, +Hardwood - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,1.1604,0.861771803,42.43,0.39,,,,,,,,,,,,,,,,,,,,, +Hardwood - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,1.1604,0.430885901,42.43,0.39,,,,,,,,,,,,,,,,,,,,, +Hardwood - 3/4 in.,StandardOpaqueMaterial,MediumSmooth,0.75,1.1604,0.646328852,42.43,0.39,,,,,,,,,,,,,,,,,,,,, +HB Part. Brd - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,1.17996,0.635614767,50,0.31,,,,,,,,,,,,,,,,,,,,, +HW CONCRETE,StandardOpaqueMaterial,Rough,4,9.09153953,0.439969489,139.83872,0.2,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +HW CONCRETE 8 in,StandardOpaqueMaterial,Rough,8,9.09153953,0.879938978,139.83872,0.2,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +I01 25mm insulation board,StandardOpaqueMaterial,MediumRough,1,0.208004154,4.807596295,2.684402305,0.289003535,0.9,0.6,0.6,,,,,,,,,,,,,,,,,, +I02 50mm insulation board,StandardOpaqueMaterial,MediumRough,2,0.208004154,9.615192591,2.684402305,0.289003535,0.9,0.6,0.6,,,,,,,,,,,,,,,,,, +IEAD NonRes Roof Insulation-1.76,StandardOpaqueMaterial,MediumRough,2.912618228,0.339740118,8.573077103,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +IEAD Roof Insulation R-3.47 IP,StandardOpaqueMaterial,MediumRough,1.178836998,0.339740118,3.469819827,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 1 1/2 in. Polyurethane Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,9,0.4704,19.13265306,100.33,0.23,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 1 1/2 in. Polyurethane Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,11,0.57,19.29824561,109.36,0.22,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 2 1/2 in. EPS Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,11,0.51648,21.29801735,76.81,0.23,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 2 1/2 in. EPS Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,13,0.60612,21.44789811,86.54,0.22,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 2 in. EPS Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,10,0.6096,16.40419948,90.4,0.23,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 2 in. EPS Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,12,0.72,16.66666667,100.33,0.22,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 2 in. Polyurethane Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,10,0.4404,22.70663034,90.4,0.23,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 2 in. Polyurethane Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,12,0.5196,23.09468822,100.33,0.22,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 2 in. XPS Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,10,0.4704,21.2585034,90.4,0.23,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 2 in. XPS Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,12,0.57,21.05263158,100.33,0.22,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 3 in. EPS Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,12,0.5004,23.98081535,75.5,0.23,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 3 in. EPS Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,14,0.57,24.56140351,86.14,0.22,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 3 in. XPS Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,12,0.39,30.76923077,75.5,0.23,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 3 in. XPS Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,14,0.45,31.11111111,86.14,0.22,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 4 1/2 in. Polyurethane Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,15,0.3504,42.80821918,60.6,0.23,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 4 1/2 in. Polyurethane Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,17,0.3996,42.54254254,71.12,0.22,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 4 in. EPS Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,14,0.4296,32.58845438,64.86,0.23,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 4 in. EPS Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,16,0.5004,31.97442046,75.5,0.22,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 4 in. XPS Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,14,0.3504,39.9543379,64.86,0.23,,,,,,,,,,,,,,,,,,,,, +Insulating Concrete Forms - 4 in. XPS Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,16,0.39,41.02564103,75.5,0.22,,,,,,,,,,,,,,,,,,,,, +Insulation 1m,StandardOpaqueMaterial,Smooth,39.37,0.13876,,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +Interior Wall Addi Insul,StandardOpaqueMaterial,MediumRough,1.00E-06,0.299941999,3.33E-06,1.399999086,0.199866248,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Light Roof - 2/5 in.,StandardOpaqueMaterial,VeryRough,0.2,2.4012,0.083291687,120,0.2,,,,,,,,,,,,,,,,,,,,, +Linoleum/cork tile - 1/4 in.,StandardOpaqueMaterial,MediumRough,0.25,0.51,0.490196078,29,0.45,,,,,,,,,,,,,,,,,,,,, +LoE CLEAR 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.6,0.17,0.22,0.84,0.055,0.078,0,0.84,0.1,1,FALSE,, +LoE SPEC SEL CLEAR 3MM,StandardGlazing,,0.118110236,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.45,0.34,0.37,0.78,0.07,0.06,0,0.84,0.03,1,FALSE,, +LoE SPEC SEL CLEAR 6MM Rev,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.43,0.42,0.3,0.77,0.06,0.07,0,0.03,0.84,1,FALSE,, +LoE SPEC SEL TINT 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.26,0.14,0.41,0.46,0.06,0.04,0,0.84,0.03,1,FALSE,, +LoE TINT 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.36,0.093,0.2,0.5,0.035,0.054,0,0.84,0.1,1,FALSE,, +Loose fill - Mineral fiber - 2 lb/ft3 - 13 3/4 in.,StandardOpaqueMaterial,Rough,13.75,0.336,40.92261905,2,0.2,,,,,,,,,,,,,,,,,,,,, +Loose fill - Mineral fiber - 2 lb/ft3 - 4 in.,StandardOpaqueMaterial,Rough,4,0.336,11.9047619,2,0.2,,,,,,,,,,,,,,,,,,,,, +Loose fill - Mineral fiber - 2 lb/ft3 - 6 1/2 in.,StandardOpaqueMaterial,Rough,6.5,0.336,19.3452381,2,0.2,,,,,,,,,,,,,,,,,,,,, +Loose fill - Mineral fiber - 2 lb/ft3 - 7 1/2 in.,StandardOpaqueMaterial,Rough,7.5,0.336,22.32142857,2,0.2,,,,,,,,,,,,,,,,,,,,, +Loose fill - Mineral fiber - 2 lb/ft3 - 8 1/4 in.,StandardOpaqueMaterial,Rough,8.25,0.336,24.55357143,2,0.2,,,,,,,,,,,,,,,,,,,,, +Loose fill - Mineral fiber - closed sidewalls - 3 1/2 in.,StandardOpaqueMaterial,Rough,3.5,0.336,10.41666667,2,0.2,,,,,,,,,,,,,,,,,,,,, +M01 100mm brick,StandardOpaqueMaterial,MediumRough,4,6.170789901,0.648215231,119.8616843,0.188688258,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +M11 100mm lightweight concrete,StandardOpaqueMaterial,MediumRough,4,3.674740053,1.088512369,79.90778954,0.200630553,0.9,0.5,0.5,,,,,,,,,,,,,,,,,, +M15 200mm heavyweight concrete,StandardOpaqueMaterial,MediumRough,8,13.52027001,0.591704159,139.8386317,0.214961307,0.9,0.5,0.5,,,,,,,,,,,,,,,,,, +Maple - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,1.14,0.877192982,41.87,0.39,,,,,,,,,,,,,,,,,,,,, +Mass NonRes Wall Insulation-0.43,StandardOpaqueMaterial,MediumRough,0.017196119,0.339740118,0.050615509,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Mass Wall Insulation R-4.23 IP,StandardOpaqueMaterial,MediumRough,1.438471204,0.339740118,4.234033978,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Mastic asphalt (heavy - 20% grit) - 1 in.,StandardOpaqueMaterial,VeryRough,1,1.2996,0.769467528,59,0.22,,,,,,,,,,,,,,,,,,,,, +MAT-CC05 4 HW CONCRETE,StandardOpaqueMaterial,Rough,4,9.089781528,0.440054581,139.8386317,0.199866246,0.9,0.85,0.85,,,,,,,,,,,,,,,,,, +MAT-CC05 8 HW CONCRETE,StandardOpaqueMaterial,Rough,8,9.089781528,0.880109162,139.8386317,0.199866246,0.9,0.85,0.85,,,,,,,,,,,,,,,,,, +MAT-SHEATH,MasslessOpaqueMaterial,,,6.240124619,0.16025321,0.043699572,0.000167192,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Metal Building Semi-Cond Wall Insulation-0.54,StandardOpaqueMaterial,MediumRough,0.604172732,0.339740118,1.778337913,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Metal Building Wall Insulation R-4.14 IP,StandardOpaqueMaterial,MediumRough,1.404445223,0.339740118,4.133881011,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Metal Deck - 1/16 in.,StandardOpaqueMaterial,Smooth,0.0625,314.4,0.000198791,488.22,0.12,,,,,,,,,,,,,,,,,,,,, +Metal Decking,StandardOpaqueMaterial,MediumSmooth,0.059055118,312.0478318,0.00018925,479.4467372,0.099933123,0.9,0.6,0.6,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 16inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,9.383,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 16inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,10.756,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 16inOC - 2x6 - R0 ins.,MasslessOpaqueMaterial,,,,0.003,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 16inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,5.309,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 16inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,5.854,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 16inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,6.92,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 16inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,7.414,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 16inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,7.815,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 24inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,12.443,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 24inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,14.569,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 24inOC - 2x6 - R0 ins.,MasslessOpaqueMaterial,,,,0.003,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 24inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,6.576,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 24inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,7.544,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 24inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,9.037,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 24inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,9.564,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Floor - 24inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,10.336,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,10.16,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,10.92,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x12 - R30 ins.,MasslessOpaqueMaterial,,,,11.42,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,12.34,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x14 - R38 ins.,MasslessOpaqueMaterial,,,,12.97,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,6.01,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,6.52,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,6.96,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x4 - R19 ins.,MasslessOpaqueMaterial,,,,6.52,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,6.39,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,6.96,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x6 - R15 ins.,MasslessOpaqueMaterial,,,,8.16,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,8.26,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,8.68,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 16inOC - 2x8 - R21 ins.,MasslessOpaqueMaterial,,,,9.01,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,12.97,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,14.13,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x12 - R30 ins.,MasslessOpaqueMaterial,,,,14.65,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,16.44,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x14 - R38 ins.,MasslessOpaqueMaterial,,,,17.13,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,7.27,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,8.06,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,8.68,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x4 - R19 ins.,MasslessOpaqueMaterial,,,,8.06,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,7.61,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,8.36,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x6 - R15 ins.,MasslessOpaqueMaterial,,,,9.89,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,10.31,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,10.76,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Roof - 24inOC - 2x8 - R21 ins.,MasslessOpaqueMaterial,,,,11.42,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 16inOC - 2x4 - R0 ins.,MasslessOpaqueMaterial,,,,0.643,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 16inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,2.924,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 16inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,3.068,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 16inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,3.199,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 16inOC - 2x4 - R5 ins.,MasslessOpaqueMaterial,,,,1.309,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 16inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,3.924,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 16inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,4.078,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 16inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,4.558,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 16inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,4.71,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 16inOC - 2x8 - R25 ins.,MasslessOpaqueMaterial,,,,4.789,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 16inOC - 2x8 - R30 ins.,MasslessOpaqueMaterial,,,,4.829,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 24inOC - 2x4 - R0 ins.,MasslessOpaqueMaterial,,,,0.658,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 24inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,3.222,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 24inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,3.386,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 24inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,3.536,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 24inOC - 2x4 - R5 ins.,MasslessOpaqueMaterial,,,,1.463,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 24inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,4.558,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 24inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,4.671,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 24inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,4.996,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 24inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,5.171,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 24inOC - 2x8 - R25 ins.,MasslessOpaqueMaterial,,,,5.263,,,,,,,,,,,,,,,,,,,,,,, +Metal Framed Wall - 24inOC - 2x8 - R30 ins.,MasslessOpaqueMaterial,,,,5.309,,,,,,,,,,,,,,,,,,,,,,, +Metal Insulated Panels - 2 1/2 in.,StandardOpaqueMaterial,Smooth,2.5,0.16644,15.02042778,28.47,0.26,,,,,,,,,,,,,,,,,,,,, +Metal Insulated Panels - 2 in.,StandardOpaqueMaterial,Smooth,2,0.16704,11.97318008,34.87,0.26,,,,,,,,,,,,,,,,,,,,, +Metal Insulated Panels - 3 in.,StandardOpaqueMaterial,Smooth,3,0.16656,18.01152738,24.11,0.26,,,,,,,,,,,,,,,,,,,,, +Metal Insulated Panels - 4 in.,StandardOpaqueMaterial,Smooth,4,0.16992,23.54048964,18.54,0.26,,,,,,,,,,,,,,,,,,,,, +Metal Insulated Panels - 5 in.,StandardOpaqueMaterial,Smooth,5,0.1698,29.44640754,15.14,0.27,,,,,,,,,,,,,,,,,,,,, +Metal Insulated Panels - 6 in.,StandardOpaqueMaterial,Smooth,6,0.16584,36.17945007,12.84,0.27,,,,,,,,,,,,,,,,,,,,, +Metal Roof Insulation R-5.21 IP,StandardOpaqueMaterial,MediumRough,1.769246081,0.339740118,5.207645452,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Metal Roof Surface,StandardOpaqueMaterial,Smooth,0.031496063,313.947603,0.000100323,488.4363635,0.119422948,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Metal Roof Surface - Cool Roof,StandardOpaqueMaterial,Smooth,0.031496063,313.947603,0.000100323,488.4363635,0.119422948,0.75,0.37,0.7,,,,,,,,,,,,,,,,,, +Metal Roof Surface - Highly Reflective,StandardOpaqueMaterial,Smooth,0.031496063,313.947603,0.000100323,488.4363635,0.119422948,0.75,0.45,0.7,,,,,,,,,,,,,,,,,, +Metal Roofing,StandardOpaqueMaterial,MediumSmooth,0.059055118,312.0478318,0.00018925,479.4467372,0.099933123,0.9,0.6,0.6,,,,,,,,,,,,,,,,,, +Metal Roofing - Cool Roof,StandardOpaqueMaterial,MediumSmooth,0.059055118,312.0478318,0.00018925,479.4467372,0.099933123,0.75,0.37,0.6,,,,,,,,,,,,,,,,,, +Metal Roofing - Highly Reflective,StandardOpaqueMaterial,MediumSmooth,0.059055118,312.0478318,0.00018925,479.4467372,0.099933123,0.75,0.45,0.6,,,,,,,,,,,,,,,,,, +Metal Screw Down Roof - No Thrml Blk - R10 ins.,MasslessOpaqueMaterial,,,,5.756,,,,,,,,,,,,,,,,,,,,,,, +Metal Screw Down Roof - No Thrml Blk - R11 ins.,MasslessOpaqueMaterial,,,,6.414,,,,,,,,,,,,,,,,,,,,,,, +Metal Screw Down Roof - No Thrml Blk - R13ins.,MasslessOpaqueMaterial,,,,6.912,,,,,,,,,,,,,,,,,,,,,,, +Metal Screw Down Roof - No Thrml Blk - R16 ins.,MasslessOpaqueMaterial,,,,8.654,,,,,,,,,,,,,,,,,,,,,,, +Metal Screw Down Roof - No Thrml Blk - R19 ins.,MasslessOpaqueMaterial,,,,9.424,,,,,,,,,,,,,,,,,,,,,,, +Metal Semi-Cond Roof Insulation-1.05,StandardOpaqueMaterial,MediumRough,1.664068118,0.339740118,4.898061868,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Metal Siding,StandardOpaqueMaterial,Smooth,0.059055118,311.7288921,0.000189444,479.999849,0.097926818,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Metal Siding - 1/16 in.,StandardOpaqueMaterial,Smooth,0.0625,314.4,0.000198791,488.22,0.12,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam - 1/16 in.,StandardOpaqueMaterial,Smooth,0.0625,3.9996,0.015626563,488.22,0.12,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam - 1/16 in. CBES,StandardOpaqueMaterial,MediumRough,0.06,4.0241,,488.22,0.12,0.85,0.37,0.85,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R10 + R10 Ins.,MasslessOpaqueMaterial,,,,15.093,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R10 + R11 Ins.,MasslessOpaqueMaterial,,,,15.613,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R10 + R13 Ins.,MasslessOpaqueMaterial,,,,16.461,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R10 + R19 Ins.,MasslessOpaqueMaterial,,,,18.451,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R11 + R11 Ins.,MasslessOpaqueMaterial,,,,15.887,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R11 + R13 Ins.,MasslessOpaqueMaterial,,,,16.764,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R11 + R19 Ins.,MasslessOpaqueMaterial,,,,18.828,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R13 + R13 Ins.,MasslessOpaqueMaterial,,,,17.402,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R13 + R19 Ins.,MasslessOpaqueMaterial,,,,19.628,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R16 + R19 Ins.,MasslessOpaqueMaterial,,,,20.497,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R19 + R19 Ins.,MasslessOpaqueMaterial,,,,20.959,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - Ins. and Filled Cavity - R19 + R10 Ins.,MasslessOpaqueMaterial,,,,23.61,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - R10 ins.,MasslessOpaqueMaterial,,,,9.529,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - R11 ins.,MasslessOpaqueMaterial,,,,10.09,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - R13 ins.,MasslessOpaqueMaterial,,,,11.268,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - R16 ins.,MasslessOpaqueMaterial,,,,13.109,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - R19 ins.,MasslessOpaqueMaterial,,,,14.605,,,,,,,,,,,,,,,,,,,,,,, +Metal Standing Seam Roof - Thrml Blk - R6 ins.,MasslessOpaqueMaterial,,,,5.208,,,,,,,,,,,,,,,,,,,,,,, +Metal Surface,StandardOpaqueMaterial,Smooth,0.031496063,313.947603,0.000100323,488.4363635,0.119422948,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Mortar - Cement - 1 3/4 in.,StandardOpaqueMaterial,Smooth,1.76,5.01,0.351297405,116,0.2,,,,,,,,,,,,,,,,,,,,, +Mortar - Cement - 1 in.,StandardOpaqueMaterial,Smooth,1.01,5.0304,0.200779262,116,0.2,,,,,,,,,,,,,,,,,,,,, +NACM_Carpet 3/4in,StandardOpaqueMaterial,Smooth,0.75,0.34691,,18,0.33,0.9,0.7,0.9,,,,,,,,,,,,,,,,,, +NACM_Concrete 4in_140lb/ft3,StandardOpaqueMaterial,MediumRough,4,13.52932,,139.78,0.22,0.75,0.92,0.75,,,,,,,,,,,,,,,,,, +NACM_Gypsum Board 5/8in,StandardOpaqueMaterial,MediumRough,0.63,1.1101,,40,0.27,0.9,0.7,0.5,,,,,,,,,,,,,,,,,, +Nonres_Floor_Insulation,MasslessOpaqueMaterial,MediumSmooth,,,16.3699766,,,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Oak - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,1.1796,0.847744998,43.93,0.39,,,,,,,,,,,,,,,,,,,,, +OSB - Oriented Strand Board - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,0.6204,0.805931657,41,0.45,,,,,,,,,,,,,,,,,,,,, +OSB - Oriented Strand Board - 3/4 in.,StandardOpaqueMaterial,MediumSmooth,0.75,0.9096,0.824538259,41,0.45,,,,,,,,,,,,,,,,,,,,, +OSB - Oriented Strand Board - 5/8 in.,StandardOpaqueMaterial,MediumSmooth,0.63,0.7596,0.829383886,41,0.45,,,,,,,,,,,,,,,,,,,,, +Perlite board - 1 1/2 in. R3.8,StandardOpaqueMaterial,Rough,1.5,0.3996,3.753753754,10,0.2,,,,,,,,,,,,,,,,,,,,, +Perlite board - 1 in. R2.5,StandardOpaqueMaterial,Rough,1,0.3996,2.502502503,10,0.2,,,,,,,,,,,,,,,,,,,,, +Perlite board - 2 in. R5.0,StandardOpaqueMaterial,Rough,2,0.3996,5.005005005,10,0.2,,,,,,,,,,,,,,,,,,,,, +Perlite board - 3/4 in. R1.9,StandardOpaqueMaterial,Rough,0.75,0.3996,1.876876877,10,0.2,,,,,,,,,,,,,,,,,,,,, +Perlite plaster - 25 lb/ft3 - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.6,0.833333333,25,0.32,,,,,,,,,,,,,,,,,,,,, +Perlite plaster - 38 lb/ft3 - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,1.2996,0.384733764,38,0.32,,,,,,,,,,,,,,,,,,,,, +Pine (oven-dried) - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,0.6396,1.563477173,23,0.45,,,,,,,,,,,,,,,,,,,,, +Plaster/Sand Aggregate - 1 in.,StandardOpaqueMaterial,Smooth,1.01,5.0304,0.200779262,116,0.2,,,,,,,,,,,,,,,,,,,,, +Plywood - 1 1/2 in.,StandardOpaqueMaterial,MediumSmooth,1.5,0.8004,1.874062969,30,0.45,,,,,,,,,,,,,,,,,,,,, +Plywood - 1 1/4 in.,StandardOpaqueMaterial,MediumSmooth,1.25,0.8004,1.56171914,30,0.45,,,,,,,,,,,,,,,,,,,,, +Plywood - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,0.8004,1.249375312,30,0.45,,,,,,,,,,,,,,,,,,,,, +Plywood - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,0.8004,0.624687656,30,0.45,,,,,,,,,,,,,,,,,,,,, +Plywood - 1/4 in.,StandardOpaqueMaterial,MediumSmooth,0.25,0.8004,0.312343828,30,0.45,,,,,,,,,,,,,,,,,,,,, +Plywood - 3/4 in.,StandardOpaqueMaterial,MediumSmooth,0.75,0.8004,0.937031484,30,0.45,,,,,,,,,,,,,,,,,,,,, +Plywood - 3/8 in.,StandardOpaqueMaterial,MediumSmooth,0.38,0.8004,0.474762619,30,0.45,,,,,,,,,,,,,,,,,,,,, +Plywood - 5/8 in.,StandardOpaqueMaterial,MediumSmooth,0.63,0.8004,0.787106447,30,0.45,,,,,,,,,,,,,,,,,,,,, +Plywood - 5/8 in. CBES,StandardOpaqueMaterial,Smooth,0.63,0.83257,,30,0.45,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Pulpboard or paper plaster - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.5004,0.999200639,38,0.32,,,,,,,,,,,,,,,,,,,,, +PYR B CLEAR 3MM,StandardGlazing,,0.118110236,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.74,0.09,0.1,0.82,0.11,0.12,0,0.84,0.2,1,FALSE,, +PYR B CLEAR 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.68,0.09,0.1,0.81,0.11,0.12,0,0.84,0.2,1,FALSE,, +R_R30,StandardOpaqueMaterial,Smooth,4.78807,0.15963,30,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +R_R38,StandardOpaqueMaterial,Smooth,6.06489,0.15963,38,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +R_T24_2013_24.86,StandardOpaqueMaterial,Smooth,3.96771,0.15963,24.86,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +R-24 Batt Wall - 8 in. R24,StandardOpaqueMaterial,VeryRough,8,0.3336,23.98081535,1.19,0.23,,,,,,,,,,,,,,,,,,,,, +R1_R14.20,StandardOpaqueMaterial,Smooth,2.26635,0.15963,14.2,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +R2_R12.90,StandardOpaqueMaterial,Smooth,2.05887,0.15963,12.9,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +R3_R17.74,StandardOpaqueMaterial,Smooth,2.83134,0.15963,17.74,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +R4_R20.28,StandardOpaqueMaterial,Smooth,3.23667,0.15963,20.28,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +Rammed Earth,StandardOpaqueMaterial,Rough,18,1.4796,12.16545012,115,0.2,,,,,,,,,,,,,,,,,,,,, +REF A CLEAR LO 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.066,0.341,0.493,0.08,0.41,0.37,0,0.84,0.4,1,FALSE,, +REF A CLEAR MID 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.11,0.27,0.43,0.14,0.31,0.35,0,0.84,0.47,1,FALSE,, +REF A TINT MID 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.06,0.13,0.42,0.09,0.14,0.35,0,0.84,0.47,1,FALSE,, +REF B CLEAR HI 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.24,0.16,0.32,0.3,0.16,0.29,0,0.84,0.6,1,FALSE,, +REF B CLEAR LO 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.15,0.22,0.38,0.2,0.23,0.33,0,0.84,0.58,1,FALSE,, +REF B TINT HI 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.15,0.09,0.33,0.18,0.08,0.28,0,0.84,0.6,1,FALSE,, +REF B TINT MID 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.1,0.11,0.41,0.13,0.1,0.32,0,0.84,0.45,1,FALSE,, +REF C CLEAR HI 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.2,0.16,0.39,0.22,0.17,0.35,0,0.84,0.55,1,FALSE,, +REF C CLEAR MID 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.17,0.2,0.42,0.19,0.21,0.38,0,0.84,0.51,1,FALSE,, +REF D CLEAR 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.429,0.308,0.379,0.334,0.453,0.505,0,0.84,0.82,1,FALSE,, +REF D TINT 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.3,0.14,0.36,0.25,0.18,0.45,0,0.84,0.82,1,FALSE,, +Roof Gravel - 1 in.,StandardOpaqueMaterial,VeryRough,1,9.9996,0.100004,159.74,0.19,,,,,,,,,,,,,,,,,,,,, +Roof Gravel - 1/2 in.,StandardOpaqueMaterial,VeryRough,0.5,9.9996,0.050002,159.74,0.19,,,,,,,,,,,,,,,,,,,,, +Roof Insulation [18],StandardOpaqueMaterial,MediumRough,6.665354331,0.339740118,19.61897926,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Roof Membrane,StandardOpaqueMaterial,VeryRough,0.374015748,1.109355488,0.337146886,69.99984791,0.348715009,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Roof Membrane - Cool Roof,StandardOpaqueMaterial,VeryRough,0.374015748,1.109355488,0.337146886,69.99984791,0.348715009,0.75,0.37,0.7,,,,,,,,,,,,,,,,,, +Roof Membrane - Highly Reflective,StandardOpaqueMaterial,VeryRough,0.374015748,1.109355488,0.337146886,69.99984791,0.348715009,0.75,0.45,0.7,,,,,,,,,,,,,,,,,, +Roofing felt - 1/8 in.,StandardOpaqueMaterial,VeryRough,0.13,8.3004,0.015661896,141,0.3,,,,,,,,,,,,,,,,,,,,, +Rubber tile - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,0.3396,2.944640754,119,0.48,,,,,,,,,,,,,,,,,,,,, +Sand aggregate - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,5.4504,0.091736386,105,0.2,,,,,,,,,,,,,,,,,,,,, +Sand aggregate - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,5.0796,0.147649421,116,0.2,,,,,,,,,,,,,,,,,,,,, +Sand aggregate - 3/8 in.,StandardOpaqueMaterial,Smooth,0.38,5.1504,0.073780677,116,0.2,,,,,,,,,,,,,,,,,,,,, +Sand aggregate - 5/8 in.,StandardOpaqueMaterial,Smooth,0.63,5.6004,0.112491965,105,0.2,,,,,,,,,,,,,,,,,,,,, +Sand aggregate on metal lath - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,5.7696,0.129991681,105,0.2,,,,,,,,,,,,,,,,,,,,, +Shingles - Asbestos cement - lapped - 1/4 in.,StandardOpaqueMaterial,VeryRough,0.25,1.1904,0.210013441,120,0.24,,,,,,,,,,,,,,,,,,,,, +Shingles - Asphalt roll siding - 1/4 in.,StandardOpaqueMaterial,VeryRough,0.25,1.6704,0.149664751,70,0.36,,,,,,,,,,,,,,,,,,,,, +Shingles - Wood - 16 in. - 7 1/2 in. exposure - 1/2 in.,StandardOpaqueMaterial,MediumRough,0.5,0.57,0.877192982,22,0.31,,,,,,,,,,,,,,,,,,,,, +Shingles - Wood - plus insulated backer board Siding - 5/16 in.,StandardOpaqueMaterial,MediumRough,0.31,0.2196,1.411657559,22,0.31,,,,,,,,,,,,,,,,,,,,, +Siding - Asphalt insulating siding - 1/2 in. bed - 1/2 in.,StandardOpaqueMaterial,VeryRough,0.5,0.3396,1.472320377,70,0.35,,,,,,,,,,,,,,,,,,,,, +Siding - Wood - bevel - 10 in. - lapped - 3/4 in.,StandardOpaqueMaterial,Rough,0.75,0.7104,1.055743243,22,0.28,,,,,,,,,,,,,,,,,,,,, +Simple Glazing,SimpleGlazing,,,,,,,,,,,1.23,0.61,0.25,,,,,,,,,,,,,, +SIPS - Crawl Space - R22 - Double 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.24768,26.24354005,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - Crawl Space - R22 - I Joist Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.23148,28.08017971,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - Crawl Space - R22 - Single 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.23952,27.13760855,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - Crawl Space - R28 - Double 2x Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.25356,32.53667771,5.85,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - Crawl Space - R28 - I Joist Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.2436,33.86699507,5.85,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - Crawl Space - R28 - Single 2x Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.2436,33.86699507,5.85,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - Crawl Space - R33 - Double 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.1842,35.28773073,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - Crawl Space - R33 - I Joist Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.16884,38.49798626,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - Crawl Space - R33 - Single 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.16884,38.49798626,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - Crawl Space - R36 - Double 2x Spline - 10 1/4 in.,StandardOpaqueMaterial,Smooth,10.25,0.26628,38.49331531,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - Crawl Space - R36 - I Joist Spline - 10 1/4 in.,StandardOpaqueMaterial,Smooth,10.25,0.2424,42.28547855,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - Crawl Space - R36 - Single 2x Spline - 10 1/4 in.,StandardOpaqueMaterial,Smooth,10.25,0.25428,40.3098946,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - No Crawl Space - R22 - Double 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.32364,20.084044,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - No Crawl Space - R22 - I Joist Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.29772,21.83259438,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - No Crawl Space - R22 - Single 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.30636,21.21686904,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - No Crawl Space - R28 - Double 2x Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.3144,26.24045802,5.85,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - No Crawl Space - R28 - I Joist Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.29376,28.08415033,5.85,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - No Crawl Space - R28 - Single 2x Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.30408,27.13101815,5.85,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - No Crawl Space - R33 - Double 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.23148,28.08017971,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - No Crawl Space - R33 - I Joist Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.19968,32.55208333,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - No Crawl Space - R33 - Single 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.2076,31.31021195,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - No Crawl Space - R36 - Double 2x Spline - 10 1/4 in.,StandardOpaqueMaterial,Smooth,10.25,0.315,32.53968254,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - No Crawl Space - R36 - I Joist Spline - 10 1/4 in.,StandardOpaqueMaterial,Smooth,10.25,0.2904,35.29614325,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - No Crawl Space - R36 - Single 2x Spline - 10 1/4 in.,StandardOpaqueMaterial,Smooth,10.25,0.2904,35.29614325,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R14 - Double 2x Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.39312,11.44688645,9.89,0.31,,,,,,,,,,,,,,,,,,,,, +SIPS - R14 - I joist Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.35304,12.746431,9.89,0.31,,,,,,,,,,,,,,,,,,,,, +SIPS - R14 - Metal Spline - 48 in.,StandardOpaqueMaterial,Smooth,48,4.14,11.5942029,1.83,0.27,,,,,,,,,,,,,,,,,,,,, +SIPS - R14 - OSB Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.303,14.85148515,9.89,0.31,,,,,,,,,,,,,,,,,,,,, +SIPS - R14 - Single 2x Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.35868,12.54600201,9.89,0.31,,,,,,,,,,,,,,,,,,,,, +SIPS - R18 - Double 2x Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.3306,13.61161525,9.89,0.31,,,,,,,,,,,,,,,,,,,,, +SIPS - R18 - I joist Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.29208,15.40673788,9.89,0.31,,,,,,,,,,,,,,,,,,,,, +SIPS - R18 - OSB Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.25968,17.32902033,9.89,0.31,,,,,,,,,,,,,,,,,,,,, +SIPS - R18 - Single 2x Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.303,14.85148515,9.89,0.31,,,,,,,,,,,,,,,,,,,,, +SIPS - R22 - Double 2x Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.32496,20.00246184,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R22 - Double 2x Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.3828,16.98014629,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R22 - I joist Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.30216,21.51178184,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R22 - I joist Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.33696,19.29012346,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R22 - Metal Spline - 48 in.,StandardOpaqueMaterial,Smooth,48,3.0396,15.79155152,1.83,0.27,,,,,,,,,,,,,,,,,,,,, +SIPS - R22 - OSB Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.28692,22.65439844,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R22 - OSB Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.28452,22.84549417,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R22 - Single 2x Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.3096,20.99483204,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R22 - Single 2x Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.35208,18.46171325,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R28 - Double 2x Spline - 8 1/2 in.,StandardOpaqueMaterial,Smooth,8.5,0.33612,25.28858741,5.71,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R28 - Double 2x Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.37992,21.71509792,5.85,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R28 - I joist Spline - 8 1/2 in.,StandardOpaqueMaterial,Smooth,8.5,0.2976,28.56182796,5.71,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R28 - I joist Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.32364,25.49128661,5.85,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R28 - Metal Spline - 48 in.,StandardOpaqueMaterial,Smooth,48,2.45688,19.53697372,1.83,0.27,,,,,,,,,,,,,,,,,,,,, +SIPS - R28 - OSB Spline - 8 1/2 in.,StandardOpaqueMaterial,Smooth,8.5,0.2976,28.56182796,5.71,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R28 - OSB Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.27768,29.71045808,5.85,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R28 - Single 2x Spline - 8 1/2 in.,StandardOpaqueMaterial,Smooth,8.5,0.3072,27.66927083,5.71,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R28 - Single 2x Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.34236,24.09744129,5.85,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R33 - Double 2x Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.23484,27.67841935,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R33 - Double 2x Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.29928,21.71879177,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R33 - I joist Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.213,30.51643192,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R33 - I joist Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.24768,26.24354005,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R33 - OSB Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.2058,31.5840622,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R33 - OSB Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.21876,29.71292741,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R33 - Single 2x Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.213,30.51643192,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R33 - Single 2x Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.26232,24.778896,7.15,0.3,,,,,,,,,,,,,,,,,,,,, +SIPS - R36 - Double 2x Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.31308,32.73923598,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R36 - Double 2x Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.3792,27.03059072,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R36 - I joist Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.2904,35.29614325,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R36 - I joist Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.32244,31.78885994,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R36 - Metal Spline - 48 in.,StandardOpaqueMaterial,Smooth,48,2.2296,21.5285253,1.83,0.27,,,,,,,,,,,,,,,,,,,,, +SIPS - R36 - OSB Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.27912,36.72255661,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R36 - OSB Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.27756,36.9289523,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R36 - Single 2x Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.30168,33.97639883,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R36 - Single 2x Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.345,29.71014493,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R44 - Double 2x Spline - 12 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,12.25,0.32016,38.26211894,4.27,0.28,,,,,,,,,,,,,,,,,,,,, +SIPS - R44 - Double 2x Spline - 12 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,12.25,0.35844,34.17587323,4.27,0.28,,,,,,,,,,,,,,,,,,,,, +SIPS - R44 - I joist Spline - 12 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,12.25,0.2802,43.71877231,4.27,0.28,,,,,,,,,,,,,,,,,,,,, +SIPS - R44 - I joist Spline - 12 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,12.25,0.31848,38.46395378,4.27,0.28,,,,,,,,,,,,,,,,,,,,, +SIPS - R44 - OSB Spline - 12 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,12.25,0.267,45.88014981,4.27,0.28,,,,,,,,,,,,,,,,,,,,, +SIPS - R44 - OSB Spline - 12 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,12.25,0.279,43.90681004,4.27,0.28,,,,,,,,,,,,,,,,,,,,, +SIPS - R44 - Single 2x Spline - 12 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,12.25,0.29352,41.73480512,4.27,0.28,,,,,,,,,,,,,,,,,,,,, +SIPS - R44 - Single 2x Spline - 12 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,12.25,0.34512,35.49490032,4.27,0.28,,,,,,,,,,,,,,,,,,,,, +SIPS - R55 - Double 2x Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.22344,45.8736126,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R55 - Double 2x Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.3,34.16666667,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R55 - I joist Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.19044,53.82272632,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R55 - I joist Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.2334,43.91602399,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R55 - OSB Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.17952,57.09670232,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R55 - OSB Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.21156,48.4496124,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R55 - Single 2x Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.20136,50.90385379,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +SIPS - R55 - Single 2x Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.25548,40.12055738,4.9,0.29,,,,,,,,,,,,,,,,,,,,, +Skylight_Frame_Width_0.000_in,,,,,0,,,,,,,,,,,,,,,,,,,,,,0, +Skylight_Frame_Width_0.334_in,,,,,0.02,,,,,,,,,,,,,,,,,,,,,,0.334, +Skylight_Frame_Width_0.430_in,,,,,0.02,,,,,,,,,,,,,,,,,,,,,,0.43, +Skylight_Frame_Width_0.709_in,,,,,0.02,,,,,,,,,,,,,,,,,,,,,,0.709, +Skylight_Frame_Width_2.339_in,,,,,0.02,,,,,,,,,,,,,,,,,,,,,,2.339, +Slate - 1/2 in.,StandardOpaqueMaterial,VeryRough,0.5,11.0304,0.045329272,119.81,0.3,,,,,,,,,,,,,,,,,,,,, +Slate or tile - 1/2 in.,StandardOpaqueMaterial,VeryRough,0.5,11.0304,0.045329272,119.81,0.3,,,,,,,,,,,,,,,,,,,,, +Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 3 1/2 in.,StandardOpaqueMaterial,Rough,3.5,0.3204,10.92384519,4.6,0.34,,,,,,,,,,,,,,,,,,,,, +Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 4 1/2 in.,StandardOpaqueMaterial,Rough,4.5,0.3204,14.04494382,4.6,0.34,,,,,,,,,,,,,,,,,,,,, +Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 4 in.,StandardOpaqueMaterial,Rough,4,0.3204,12.48439451,4.6,0.34,,,,,,,,,,,,,,,,,,,,, +Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 5 1/2 in.,StandardOpaqueMaterial,Rough,5.5,0.3204,17.16604245,4.6,0.34,,,,,,,,,,,,,,,,,,,,, +Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 5 in.,StandardOpaqueMaterial,Rough,5,0.3204,15.60549313,4.6,0.34,,,,,,,,,,,,,,,,,,,,, +Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 6 1/2 in.,StandardOpaqueMaterial,Rough,6.5,0.3204,20.28714107,4.6,0.34,,,,,,,,,,,,,,,,,,,,, +Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 6 in.,StandardOpaqueMaterial,Rough,6,0.3204,18.72659176,4.6,0.34,,,,,,,,,,,,,,,,,,,,, +Spray applied - Glass fiber - 3.9 lb/ft3 - 3 1/2 in.,StandardOpaqueMaterial,MediumRough,3.5,0.27,12.96296296,3.9,0.23,,,,,,,,,,,,,,,,,,,,, +Spray applied - Glass fiber - 3.9 lb/ft3 - 4 1/2 in.,StandardOpaqueMaterial,MediumRough,4.5,0.27,16.66666667,3.9,0.23,,,,,,,,,,,,,,,,,,,,, +Spray applied - Glass fiber - 3.9 lb/ft3 - 4 in.,StandardOpaqueMaterial,MediumRough,4,0.27,14.81481481,3.9,0.23,,,,,,,,,,,,,,,,,,,,, +Spray applied - Glass fiber - 3.9 lb/ft3 - 5 1/2 in.,StandardOpaqueMaterial,MediumRough,5.5,0.27,20.37037037,3.9,0.23,,,,,,,,,,,,,,,,,,,,, +Spray applied - Glass fiber - 3.9 lb/ft3 - 5 in.,StandardOpaqueMaterial,MediumRough,5,0.27,18.51851852,3.9,0.23,,,,,,,,,,,,,,,,,,,,, +Spray applied - Glass fiber - 3.9 lb/ft3 - 6 1/2 in.,StandardOpaqueMaterial,MediumRough,6.5,0.27,24.07407407,3.9,0.23,,,,,,,,,,,,,,,,,,,,, +Spray applied - Glass fiber - 3.9 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,0.27,22.22222222,3.9,0.23,,,,,,,,,,,,,,,,,,,,, +Spray applied - Polyurethane foam - 0.5 lb/ft3 - 3 1/2 in.,StandardOpaqueMaterial,Rough,3.5,0.3,11.66666667,0.5,0.35,,,,,,,,,,,,,,,,,,,,, +Spray applied - Polyurethane foam - 0.5 lb/ft3 - 4 1/2 in.,StandardOpaqueMaterial,Rough,4.5,0.3,15,0.5,0.35,,,,,,,,,,,,,,,,,,,,, +Spray applied - Polyurethane foam - 0.5 lb/ft3 - 4 in.,StandardOpaqueMaterial,Rough,4,0.3,13.33333333,0.5,0.35,,,,,,,,,,,,,,,,,,,,, +Spray applied - Polyurethane foam - 0.5 lb/ft3 - 5 1/2 in.,StandardOpaqueMaterial,Rough,5.5,0.3,18.33333333,0.5,0.35,,,,,,,,,,,,,,,,,,,,, +Spray applied - Polyurethane foam - 0.5 lb/ft3 - 5 in.,StandardOpaqueMaterial,Rough,5,0.3,16.66666667,0.5,0.35,,,,,,,,,,,,,,,,,,,,, +Spray applied - Polyurethane foam - 0.5 lb/ft3 - 6 1/2 in.,StandardOpaqueMaterial,Rough,6.5,0.3,21.66666667,0.5,0.35,,,,,,,,,,,,,,,,,,,,, +Spray applied - Polyurethane foam - 0.5 lb/ft3 - 6 in.,StandardOpaqueMaterial,Rough,6,0.3,20,0.5,0.35,,,,,,,,,,,,,,,,,,,,, +Spray applied - Polyurethane foam - 3.0 lb/ft3 - 3 1/2 in.,StandardOpaqueMaterial,Rough,3.5,0.20004,17.4965007,3,0.35,,,,,,,,,,,,,,,,,,,,, +Spray applied - Polyurethane foam - 3.0 lb/ft3 - 4 1/2 in.,StandardOpaqueMaterial,Rough,4.5,0.20004,22.4955009,3,0.35,,,,,,,,,,,,,,,,,,,,, +Spray applied - Polyurethane foam - 3.0 lb/ft3 - 4 in.,StandardOpaqueMaterial,Rough,4,0.20004,19.9960008,3,0.35,,,,,,,,,,,,,,,,,,,,, +Spray applied - Polyurethane foam - 3.0 lb/ft3 - 5 1/2 in.,StandardOpaqueMaterial,Rough,5.5,0.20004,27.4945011,3,0.35,,,,,,,,,,,,,,,,,,,,, +Spray applied - Polyurethane foam - 3.0 lb/ft3 - 5 in.,StandardOpaqueMaterial,Rough,5,0.20004,24.995001,3,0.35,,,,,,,,,,,,,,,,,,,,, +Spray applied - Polyurethane foam - 3.0 lb/ft3 - 6 1/2 in.,StandardOpaqueMaterial,Rough,6.5,0.20004,32.4935013,3,0.35,,,,,,,,,,,,,,,,,,,,, +Spray applied - Polyurethane foam - 3.0 lb/ft3 - 6 in.,StandardOpaqueMaterial,Rough,6,0.20004,29.9940012,3,0.35,,,,,,,,,,,,,,,,,,,,, +Std Wood 6 in.,StandardOpaqueMaterial,MediumSmooth,5.905511811,0.832016616,7.097829176,33.71109871,0.289003535,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Std Wood 6inch Furnishings,StandardOpaqueMaterial,MediumSmooth,5.91,0.83257,,33.71,0.29,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Steel Frame NonRes Wall Insulation-0.73,StandardOpaqueMaterial,MediumRough,0.79835618,0.339740118,2.34990258,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Steel Frame Wall Insulation R-1.02 IP,StandardOpaqueMaterial,MediumRough,0.347890885,0.339740118,1.023991182,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Steel Frame/Cavity,StandardOpaqueMaterial,MediumRough,3.500007095,0.583217221,6.001206697,40.03997387,0.119919749,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Stone - 1 in.,StandardOpaqueMaterial,MediumRough,1,12.504,0.079974408,139.78,0.22,,,,,,,,,,,,,,,,,,,,, +Straw Bale - Int and Ext Stucco - 18 in.,StandardOpaqueMaterial,Smooth,19.5,0.6504,29.98154982,12.95,0.11,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Double glass with no low e coatings - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.81,2.802469136,29.09,0.26,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Double glass with no low e coatings - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.5304,6.165158371,20.44,0.26,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Double glass with no low e coatings - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.64764,6.901982583,15.23,0.27,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Double glass with no low e coatings - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,0.7704,7.359813084,12.22,0.27,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Double glass with no low e coatings - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,0.8904,7.715633423,10.26,0.27,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Double glass with no low e coatings - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.02,7.911764706,8.88,0.27,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Double glass with no low e coatings - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.39,4.692307692,35.69,0.26,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Double glass with no low e coatings - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.4596,5.548302872,25.92,0.26,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Single glass pane. stone. or metal pane - No Ins.,StandardOpaqueMaterial,Smooth,2.52,1.2804,1.968134958,41.9,0.26,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Single glass pane. stone. or metal pane - R10 Ins.,StandardOpaqueMaterial,Smooth,3.52,0.5904,5.962059621,30.2,0.26,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Single glass pane. stone. or metal pane - R15 Ins.,StandardOpaqueMaterial,Smooth,4.72,0.6996,6.746712407,22.79,0.26,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Single glass pane. stone. or metal pane - R20 Ins.,StandardOpaqueMaterial,Smooth,5.92,0.81324,7.27952388,18.37,0.26,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Single glass pane. stone. or metal pane - R25 Ins.,StandardOpaqueMaterial,Smooth,7.12,0.93372,7.625412329,15.45,0.27,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Single glass pane. stone. or metal pane - R30 Ins.,StandardOpaqueMaterial,Smooth,8.32,1.05,7.923809524,13.37,0.27,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Single glass pane. stone. or metal pane - R4 Ins.,StandardOpaqueMaterial,Smooth,2.08,0.48624,4.277722935,50.36,0.25,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Single glass pane. stone. or metal pane - R7 Ins.,StandardOpaqueMaterial,Smooth,2.8,0.5304,5.279034691,37.69,0.26,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Triple or low e glass - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.6504,3.490159902,29.09,0.26,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Triple or low e glass - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.51,6.411764706,20.44,0.26,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Triple or low e glass - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.63636,7.024325853,15.23,0.27,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Triple or low e glass - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,0.76476,7.414090695,12.22,0.27,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Triple or low e glass - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,0.88404,7.771141577,10.26,0.27,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Triple or low e glass - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.0104,7.986935867,8.88,0.27,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Triple or low e glass - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.36,5.083333333,35.69,0.26,,,,,,,,,,,,,,,,,,,,, +Structural Glazing - Triple or low e glass - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.43836,5.8171366,25.92,0.26,,,,,,,,,,,,,,,,,,,,, +Stucco - 3/8 in.,StandardOpaqueMaterial,Smooth,0.38,5.0004,0.07599392,115.81,0.2,,,,,,,,,,,,,,,,,,,,, +Stucco - 7/8 in.,StandardOpaqueMaterial,Smooth,0.88,4.86,0.181069959,115.81,0.2,,,,,,,,,,,,,,,,,,,,, +Stucco - 7/8 in. CBES,StandardOpaqueMaterial,MediumRough,0.88,4.85668,,115.81,0.2,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +Synthetic Stucco - EIFS finish - 1 in.,StandardOpaqueMaterial,Smooth,1,0.2496,4.006410256,1.5,0.35,,,,,,,,,,,,,,,,,,,,, +Terrazzo - 1 in.,StandardOpaqueMaterial,Rough,1,12.5004,0.07999744,160,0.19,,,,,,,,,,,,,,,,,,,,, +Test,Test,Test,0.1,0.1,0.1,0.1,0.1,0.1,0.1,0.1,,,,,,,,,,,,,,,,,, +Theoretical Glass [167],StandardGlazing,,0.118110236,14.61090512,0.06844203,,,,,,,,,,SpectralAverage,0.2374,0.7126,0.7126,0.2512,0.6988,0.6988,0,0.985,0.985,1,FALSE,, +Theoretical Glass [197],StandardGlazing,,0.118110236,0.28773908,3.475370816,,,,,,,,,,SpectralAverage,0.2349,0.7151,0.7151,0.2512,0.6988,0.6988,0,0.9,0.9,1,FALSE,, +Theoretical Glass [202],StandardGlazing,,0.118110236,0.133122659,7.511869212,,,,,,,,,,SpectralAverage,0.2325,0.7175,0.7175,0.3192,0.6308,0.6308,0,0.9,0.9,1,FALSE,, +Theoretical Glass [207],StandardGlazing,,0.118110236,0.092215175,10.84420217,,,,,,,,,,SpectralAverage,0.3311,0.6189,0.6189,0.44,0.51,0.51,0,0.9,0.9,1,FALSE,, +Theoretical Glass [216],StandardGlazing,,0.118110236,0.092215175,10.84420217,,,,,,,,,,SpectralAverage,0.3801,0.5699,0.5699,0.5079,0.4421,0.4421,0,0.9,0.9,1,FALSE,, +Theoretical Glass [221],StandardGlazing,,0.118110236,0.061707899,16.20538077,,,,,,,,,,SpectralAverage,0.4296,0.5204,0.5204,0.4503,0.4997,0.4997,0,0.9,0.9,1,FALSE,, +Theoretical Glass 297,StandardGlazing,,0.118110236,0.071803727,13.92685363,,,,,,,,,,SpectralAverage,0.375039,0.574961,0.574961,0.529698,0.420302,0.420302,0,0.9,0.9,1,FALSE,, +Theoretical Glass 347,StandardGlazing,,0.118110236,0.071816901,13.92429898,,,,,,,,,,SpectralAverage,0.315861,0.634139,0.634139,0.479911,0.470089,0.470089,0,0.9,0.9,1,FALSE,, +Tile Gap - 3/4 in.,StandardOpaqueMaterial,VeryRough,0.75,0.6612,1.13430127,70,0.24,,,,,,,,,,,,,,,,,,,,, +Typical Air Wall,MasslessOpaqueMaterial,,,6.240124619,0.16025321,0.043699572,0.000167192,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Typical Carpet Pad,MasslessOpaqueMaterial,VeryRough,,,1.229230374,,,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +Typical Insulation,MasslessOpaqueMaterial,MediumSmooth,,6.240124619,0.16025321,0.043699572,0.000167192,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +U 0.11 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.11,0.34,0.374,,,,,,,,,,,,,, +U 0.11 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.11,0.38,0.418,,,,,,,,,,,,,, +U 0.12 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.12,0.34,0.374,,,,,,,,,,,,,, +U 0.12 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.12,0.38,0.418,,,,,,,,,,,,,, +U 0.13 SHGC 0.32 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.13,0.32,0.352,,,,,,,,,,,,,, +U 0.13 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.13,0.38,0.418,,,,,,,,,,,,,, +U 0.14 SHGC 0.31 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.14,0.31,0.341,,,,,,,,,,,,,, +U 0.14 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.14,0.34,0.374,,,,,,,,,,,,,, +U 0.14 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.14,0.36,0.396,,,,,,,,,,,,,, +U 0.14 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.14,0.38,0.418,,,,,,,,,,,,,, +U 0.15 SHGC 0.31 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.15,0.31,0.341,,,,,,,,,,,,,, +U 0.15 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.15,0.34,0.374,,,,,,,,,,,,,, +U 0.17 SHGC 0.31 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.17,0.31,0.341,,,,,,,,,,,,,, +U 0.17 SHGC 0.32 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.17,0.32,0.352,,,,,,,,,,,,,, +U 0.17 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.17,0.36,0.396,,,,,,,,,,,,,, +U 0.18 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.18,0.22,0.242,,,,,,,,,,,,,, +U 0.18 SHGC 0.24 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.18,0.24,0.264,,,,,,,,,,,,,, +U 0.20 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.2,0.19,0.209,,,,,,,,,,,,,, +U 0.20 SHGC 0.20 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.2,0.2,0.22,,,,,,,,,,,,,, +U 0.20 SHGC 0.21 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.2,0.21,0.231,,,,,,,,,,,,,, +U 0.20 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.2,0.22,0.242,,,,,,,,,,,,,, +U 0.23 SHGC 0.31 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.23,0.31,0.341,,,,,,,,,,,,,, +U 0.23 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.23,0.34,0.374,,,,,,,,,,,,,, +U 0.25 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.25,0.22,0.242,,,,,,,,,,,,,, +U 0.25 SHGC 0.24 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.25,0.24,0.264,,,,,,,,,,,,,, +U 0.26 SHGC 0.40 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.26,0.4,0.44,,,,,,,,,,,,,, +U 0.29 SHGC 0.40 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.29,0.4,0.44,,,,,,,,,,,,,, +U 0.32 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.32,0.36,0.396,,,,,,,,,,,,,, +U 0.35 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.35,0.22,0.242,,,,,,,,,,,,,, +U 0.35 SHGC 0.24 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.35,0.24,0.264,,,,,,,,,,,,,, +U 0.42 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.42,0.34,0.374,,,,,,,,,,,,,, +U 0.45 SHGC 0.33 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.45,0.33,0.363,,,,,,,,,,,,,, +U 0.47 SHGC 0.33 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.47,0.33,0.363,,,,,,,,,,,,,, +U 0.48 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.48,0.19,0.209,,,,,,,,,,,,,, +U 0.48 SHGC 0.21 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.48,0.21,0.231,,,,,,,,,,,,,, +U 0.48 SHGC 0.20 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.48,0.2,0.22,,,,,,,,,,,,,, +U 0.48 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.48,0.22,0.242,,,,,,,,,,,,,, +U 0.50 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.22,0.242,,,,,,,,,,,,,, +U 0.50 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.23,0.253,,,,,,,,,,,,,, +U 0.52 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.52,0.39,0.31,,,,,,,,,,,,,, +U 0.52 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.52,0.49,0.41,,,,,,,,,,,,,, +U 0.52 SHGC 0.615 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.52,0.615,0.41,,,,,,,,,,,,,, +U 0.54 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.54,0.23,0.253,,,,,,,,,,,,,, +U 0.58 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.58,0.19,0.15,,,,,,,,,,,,,, +U 0.58 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.58,0.36,0.25,,,,,,,,,,,,,, +U 0.59 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.59,0.36,0.27,,,,,,,,,,,,,, +U 0.59 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.59,0.39,0.31,,,,,,,,,,,,,, +U 0.60 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.6,0.23,0.253,,,,,,,,,,,,,, +U 0.61 SHGC 0.77 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.61,0.77,0.6,,,,,,,,,,,,,, +U 0.62 SHGC 0.20 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.62,0.2,0.22,,,,,,,,,,,,,, +U 0.62 SHGC 0.21 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.62,0.21,0.231,,,,,,,,,,,,,, +U 0.62 SHGC 0.41 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.62,0.41,0.32,,,,,,,,,,,,,, +U 0.65 SHGC 0.35 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.65,0.35,0.25,,,,,,,,,,,,,, +U 0.69 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.69,0.19,0.15,,,,,,,,,,,,,, +U 0.69 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.69,0.36,0.23,,,,,,,,,,,,,, +U 0.69 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.69,0.39,0.23,,,,,,,,,,,,,, +U 0.69 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.69,0.49,0.38,,,,,,,,,,,,,, +U 0.69 SHGC 0.64 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.69,0.64,0.55,,,,,,,,,,,,,, +U 0.69 SHGC 0.68 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.69,0.68,0.55,,,,,,,,,,,,,, +U 0.72 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.72,0.25,0.13,,,,,,,,,,,,,, +U 0.72 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.72,0.36,0.23,,,,,,,,,,,,,, +U 0.72 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.72,0.39,0.23,,,,,,,,,,,,,, +U 0.74 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.74,0.55,0.4,,,,,,,,,,,,,, +U 0.74 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.74,0.65,0.55,,,,,,,,,,,,,, +U 0.75 SHGC 0.35 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.35,0.23,,,,,,,,,,,,,, +U 0.81 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.81,0.65,0.55,,,,,,,,,,,,,, +U 0.85 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.85,0.65,0.55,,,,,,,,,,,,,, +U 0.87 SHGC 0.58 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.87,0.58,0.55,,,,,,,,,,,,,, +U 0.87 SHGC 0.71 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.87,0.71,0.6,,,,,,,,,,,,,, +U 0.87 SHGC 0.77 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.87,0.77,0.6,,,,,,,,,,,,,, +U 0.98 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.19,0.15,,,,,,,,,,,,,, +U 0.98 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.36,0.25,,,,,,,,,,,,,, +U 1.10 SHGC 0.62 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.1,0.62,0.55,,,,,,,,,,,,,, +U 1.10 SHGC 0.77 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.1,0.77,0.6,,,,,,,,,,,,,, +U 1.15 SHGC 0.77 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.15,0.77,0.6,,,,,,,,,,,,,, +U 1.17 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.17,0.19,0.15,,,,,,,,,,,,,, +U 1.17 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.17,0.36,0.23,,,,,,,,,,,,,, +U 1.17 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.17,0.39,0.23,,,,,,,,,,,,,, +U 1.17 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.17,0.49,0.38,,,,,,,,,,,,,, +U 1.17 SHGC 0.64 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.17,0.64,0.55,,,,,,,,,,,,,, +U 1.17 SHGC 0.68 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.17,0.68,0.55,,,,,,,,,,,,,, +U 1.22 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.25,0.11,,,,,,,,,,,,,, +U 1.22 SHGC 0.54 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.54,0.38,,,,,,,,,,,,,, +U 1.30 SHGC 0.27 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.3,0.27,0.25,,,,,,,,,,,,,, +U 1.30 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.3,0.34,0.25,,,,,,,,,,,,,, +U 1.30 SHGC 0.62 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.3,0.62,0.55,,,,,,,,,,,,,, +U 1.30 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.3,0.65,0.55,,,,,,,,,,,,,, +U 1.36 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.36,0.19,0.15,,,,,,,,,,,,,, +U 1.36 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.36,0.36,0.23,,,,,,,,,,,,,, +U 1.36 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.36,0.39,0.23,,,,,,,,,,,,,, +U 1.36 SHGC 0.61 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.36,0.61,0.23,,,,,,,,,,,,,, +U 1.70 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.7,0.36,0.23,,,,,,,,,,,,,, +U 1.80 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.8,0.36,0.23,,,,,,,,,,,,,, +U 1.90 SHGC 0.27 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.9,0.27,0.25,,,,,,,,,,,,,, +U 1.90 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.9,0.34,0.25,,,,,,,,,,,,,, +U 1.90 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.9,0.39,0.25,,,,,,,,,,,,,, +U 1.90 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.9,0.65,0.25,,,,,,,,,,,,,, +U 1.98 SHGC 0.16 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.16,0.15,,,,,,,,,,,,,, +U 1.98 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.19,0.15,,,,,,,,,,,,,, +U 1.98 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.36,0.25,,,,,,,,,,,,,, +U 1.98 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.39,0.25,,,,,,,,,,,,,, +U 1.98 SHGC 0.61 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.61,0.25,,,,,,,,,,,,,, +U0.47_SHGC_0.49_SimpleGlazing_Window_05,SimpleGlazing,,,,,,,,,,Air,0.47,0.49,0.81,,,,,,,,,,,,,, +U0.47_SHGC0.46_SimpleGlazing_Window_07,SimpleGlazing,,,,,,,,,,Air,0.47,0.46,0.81,,,,,,,,,,,,,, +U0.47_SHGC0.47_SimpleGlazing_Window_06,SimpleGlazing,,,,,,,,,,Air,0.47,0.47,0.81,,,,,,,,,,,,,, +U0.47_SHGC0.47_SimpleGlazing_Window_11,SimpleGlazing,,,,,,,,,,Air,0.47,0.47,0.81,,,,,,,,,,,,,, +U0.47_SHGC0.5_SimpleGlazing_Window_03,SimpleGlazing,,,,,,,,,,Air,0.47,0.5,0.81,,,,,,,,,,,,,, +U0.77_SHGC_0.77_SimpleGlazing_Window_02,SimpleGlazing,,,,,,,,,,Air,0.77,0.77,0.81,,,,,,,,,,,,,, +U0.77_SHGC0.5_SimpleGlazing_Window_09,SimpleGlazing,,,,,,,,,,Air,0.77,0.5,0.81,,,,,,,,,,,,,, +U0.77_SHGC0.61_SimpleGlazing_Window_08,SimpleGlazing,,,,,,,,,,Air,0.77,0.61,0.81,,,,,,,,,,,,,, +U0.77_SHGC0.62_SimpleGlazing_Window_04,SimpleGlazing,,,,,,,,,,Air,0.77,0.62,0.81,,,,,,,,,,,,,, +U1.23_SHGC0.5_SimpleGlazing_Window_12,SimpleGlazing,,,,,,,,,,Air,1.23,0.5,0.81,,,,,,,,,,,,,, +U1.23_SHGC0.82_SimpleGlazing_Window_01,SimpleGlazing,,,,,,,,,,Air,1.23,0.82,0.81,,,,,,,,,,,,,, +U1.23_SHGC0.82_SimpleGlazing_Window_10,SimpleGlazing,,,,,,,,,,Air,1.23,0.62,0.81,,,,,,,,,,,,,, +Vapor permeable felt - 1/8 in.,StandardOpaqueMaterial,Rough,0.13,2.0796,0.062512022,22,0.3,,,,,,,,,,,,,,,,,,,,, +Vapor seal - 2 layers of mopped 15 lb felt - 1/4 in.,StandardOpaqueMaterial,Rough,0.25,2.0796,0.120215426,22,0.3,,,,,,,,,,,,,,,,,,,,, +Vapor seal - plastic film - 1/16 in.,StandardOpaqueMaterial,Rough,0.63,62.4996,0.010080065,30,0.3,,,,,,,,,,,,,,,,,,,,, +Vermiculite aggregate - 45 lb/ft3 - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,1.7004,0.294048459,45,0.32,,,,,,,,,,,,,,,,,,,,, +W_m1_R15,StandardOpaqueMaterial,Smooth,2.39403,0.15963,15,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +W_m2_R19,StandardOpaqueMaterial,Smooth,3.03244,0.15963,19,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +W_m3_R21,StandardOpaqueMaterial,Smooth,3.35165,0.15963,21,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +W_T24_2013_R13.99,StandardOpaqueMaterial,Smooth,2.23284,0.15963,13.99,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +W1_R8.60,StandardOpaqueMaterial,Smooth,1.37252,0.15963,8.6,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +W2_R11.13,StandardOpaqueMaterial,Smooth,1.77634,0.15963,11.13,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +W3_R11.36,StandardOpaqueMaterial,Smooth,1.81305,0.15963,11.36,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +W4_R12.62,StandardOpaqueMaterial,Smooth,2.01414,0.15963,12.62,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, +Wall Insulation [31],StandardOpaqueMaterial,MediumRough,1.326771654,0.299525982,4.429571171,5.680944412,0.199914015,0.9,0.5,0.5,,,,,,,,,,,,,,,,,, +Wood - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,1.0404,0.961168781,37.94,0.39,,,,,,,,,,,,,,,,,,,,, +Wood - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,1.0404,0.480584391,37.94,0.39,,,,,,,,,,,,,,,,,,,,, +Wood - 2 in.,StandardOpaqueMaterial,MediumSmooth,2,1.0404,1.922337562,37.94,0.39,,,,,,,,,,,,,,,,,,,,, +Wood - 4 in.,StandardOpaqueMaterial,MediumSmooth,4,1.0404,3.844675125,37.94,0.39,,,,,,,,,,,,,,,,,,,,, +Wood Frame NonRes Wall Insulation-0.73,StandardOpaqueMaterial,MediumRough,0.79835618,0.339740118,2.34990258,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Wood Frame Wall Insulation R-1.61 IP,StandardOpaqueMaterial,MediumRough,0.54621365,0.339740118,1.607739625,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x10 - R11 ins.,MasslessOpaqueMaterial,,,,10.783,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x10 - R13 ins.,MasslessOpaqueMaterial,,,,12.4765,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x10 - R19 ins.,MasslessOpaqueMaterial,,,,17.1561,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x10 - R21 ins.,MasslessOpaqueMaterial,,,,18.5953,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x10 - R22 ins.,MasslessOpaqueMaterial,,,,19.2942,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,21.3129,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,24.4379,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x10 - R38 ins.,MasslessOpaqueMaterial,,,,28.8982,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x10 - R44 ins.,MasslessOpaqueMaterial,,,,31.873,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x10 - R49 ins.,MasslessOpaqueMaterial,,,,34.1444,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x10 - R60 ins.,MasslessOpaqueMaterial,,,,38.5802,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x12 - R11 ins.,MasslessOpaqueMaterial,,,,11.0136,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x12 - R13 ins.,MasslessOpaqueMaterial,,,,12.7862,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x12 - R19 ins.,MasslessOpaqueMaterial,,,,17.7471,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x12 - R21 ins.,MasslessOpaqueMaterial,,,,19.2917,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x12 - R22 ins.,MasslessOpaqueMaterial,,,,20.045,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x12 - R25 ins.,MasslessOpaqueMaterial,,,,22.2328,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x12 - R30 ins.,MasslessOpaqueMaterial,,,,25.6551,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,30.6158,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x12 - R44 ins.,MasslessOpaqueMaterial,,,,33.9752,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x12 - R49 ins.,MasslessOpaqueMaterial,,,,36.5684,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x12 - R60 ins.,MasslessOpaqueMaterial,,,,41.7037,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,9.0352,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,10.1946,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x4 - R19 ins.,MasslessOpaqueMaterial,,,,13.1185,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x4 - R21 ins.,MasslessOpaqueMaterial,,,,13.9437,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x4 - R22 ins.,MasslessOpaqueMaterial,,,,14.333,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x4 - R25 ins.,MasslessOpaqueMaterial,,,,15.4178,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x4 - R30 ins.,MasslessOpaqueMaterial,,,,16.9895,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x4 - R38 ins.,MasslessOpaqueMaterial,,,,19.0316,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x4 - R44 ins.,MasslessOpaqueMaterial,,,,20.278,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x4 - R49 ins.,MasslessOpaqueMaterial,,,,21.1742,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x4 - R60 ins.,MasslessOpaqueMaterial,,,,22.7998,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,9.98167,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,11.416,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,15.2129,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,16.3338,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x6 - R22 ins.,MasslessOpaqueMaterial,,,,16.8706,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x6 - R25 ins.,MasslessOpaqueMaterial,,,,18.394,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x6 - R30 ins.,MasslessOpaqueMaterial,,,,20.6759,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x6 - R38 ins.,MasslessOpaqueMaterial,,,,23.7814,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x6 - R44 ins.,MasslessOpaqueMaterial,,,,25.7599,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x6 - R49 ins.,MasslessOpaqueMaterial,,,,27.2236,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x6 - R60 ins.,MasslessOpaqueMaterial,,,,29.9711,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x8 - R11 ins.,MasslessOpaqueMaterial,,,,10.4438,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x8 - R13 ins.,MasslessOpaqueMaterial,,,,12.0246,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,16.313,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x8 - R21 ins.,MasslessOpaqueMaterial,,,,17.6089,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,18.2344,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x8 - R25 ins.,MasslessOpaqueMaterial,,,,20.0271,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x8 - R30 ins.,MasslessOpaqueMaterial,,,,22.7622,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x8 - R38 ins.,MasslessOpaqueMaterial,,,,26.584,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x8 - R44 ins.,MasslessOpaqueMaterial,,,,29.0808,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x8 - R49 ins.,MasslessOpaqueMaterial,,,,30.96,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 16inOC - 2x8 - R60 ins.,MasslessOpaqueMaterial,,,,34.5633,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x10 - R11 ins.,MasslessOpaqueMaterial,,,,10.8472,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x10 - R13 ins.,MasslessOpaqueMaterial,,,,12.6291,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x10 - R19 ins.,MasslessOpaqueMaterial,,,,17.6705,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x10 - R21 ins.,MasslessOpaqueMaterial,,,,19.2568,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x10 - R22 ins.,MasslessOpaqueMaterial,,,,20.0334,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,22.2995,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,25.8772,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x10 - R38 ins.,MasslessOpaqueMaterial,,,,31.1355,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x10 - R44 ins.,MasslessOpaqueMaterial,,,,34.7459,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x10 - R49 ins.,MasslessOpaqueMaterial,,,,37.5607,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x10 - R60 ins.,MasslessOpaqueMaterial,,,,43.2077,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x12 - R11 ins.,MasslessOpaqueMaterial,,,,11.0095,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x12 - R13 ins.,MasslessOpaqueMaterial,,,,12.8496,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x12 - R19 ins.,MasslessOpaqueMaterial,,,,18.1053,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x12 - R21 ins.,MasslessOpaqueMaterial,,,,19.7743,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x12 - R22 ins.,MasslessOpaqueMaterial,,,,20.594,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x12 - R25 ins.,MasslessOpaqueMaterial,,,,22.9964,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x12 - R30 ins.,MasslessOpaqueMaterial,,,,26.8204,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,32.5111,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x12 - R44 ins.,MasslessOpaqueMaterial,,,,36.4678,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x12 - R49 ins.,MasslessOpaqueMaterial,,,,39.581,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x12 - R60 ins.,MasslessOpaqueMaterial,,,,45.903,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,9.54677,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,10.9003,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x4 - R19 ins.,MasslessOpaqueMaterial,,,,14.4614,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x4 - R21 ins.,MasslessOpaqueMaterial,,,,15.5068,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x4 - R22 ins.,MasslessOpaqueMaterial,,,,16.0065,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x4 - R25 ins.,MasslessOpaqueMaterial,,,,17.421,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x4 - R30 ins.,MasslessOpaqueMaterial,,,,19.5305,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x4 - R38 ins.,MasslessOpaqueMaterial,,,,22.3835,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x4 - R44 ins.,MasslessOpaqueMaterial,,,,24.1906,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x4 - R49 ins.,MasslessOpaqueMaterial,,,,25.5222,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x4 - R60 ins.,MasslessOpaqueMaterial,,,,28.0096,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,10.2668,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,11.8491,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,16.1804,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,17.5004,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x6 - R22 ins.,MasslessOpaqueMaterial,,,,18.1394,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x6 - R25 ins.,MasslessOpaqueMaterial,,,,19.9777,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x6 - R30 ins.,MasslessOpaqueMaterial,,,,22.802,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x6 - R38 ins.,MasslessOpaqueMaterial,,,,26.7885,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x6 - R44 ins.,MasslessOpaqueMaterial,,,,29.4185,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x6 - R49 ins.,MasslessOpaqueMaterial,,,,31.4116,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x6 - R60 ins.,MasslessOpaqueMaterial,,,,35.2661,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x8 - R11 ins.,MasslessOpaqueMaterial,,,,10.6047,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x8 - R13 ins.,MasslessOpaqueMaterial,,,,12.3015,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,17.0358,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x8 - R21 ins.,MasslessOpaqueMaterial,,,,18.5054,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,19.2214,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x8 - R25 ins.,MasslessOpaqueMaterial,,,,21.298,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x8 - R30 ins.,MasslessOpaqueMaterial,,,,24.5383,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x8 - R38 ins.,MasslessOpaqueMaterial,,,,29.2172,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x8 - R44 ins.,MasslessOpaqueMaterial,,,,32.3739,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x8 - R49 ins.,MasslessOpaqueMaterial,,,,34.804,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Attic Floor - 24inOC - 2x8 - R60 ins.,MasslessOpaqueMaterial,,,,39.5997,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 16inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,21.3129,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 16inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,24.4379,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 16inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,30.6158,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 16inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,9.98167,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 16inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,11.416,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 16inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,15.2129,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 16inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,16.313,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 16inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,18.2344,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 24inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,22.2995,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 24inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,25.8772,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 24inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,32.5111,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 24inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,10.2668,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 24inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,11.8491,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 24inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,16.1804,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 24inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,17.0358,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Floor - 24inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,19.2214,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x10 - R22 ins.,MasslessOpaqueMaterial,,,,19.2942,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,21.3129,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,24.4379,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x12 - R30 ins.,MasslessOpaqueMaterial,,,,25.6551,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,30.6158,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x14 - R38 ins.,MasslessOpaqueMaterial,,,,30.6158,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,9.0352,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,10.1946,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,11.2537,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x4 - R19 ins.,MasslessOpaqueMaterial,,,,13.1185,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,9.98167,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,11.416,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x6 - R15 ins.,MasslessOpaqueMaterial,,,,12.7607,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,15.2129,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,16.3338,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,16.313,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 16inOC - 2x8 - R21 ins.,MasslessOpaqueMaterial,,,,17.6089,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x10 - R22 ins.,MasslessOpaqueMaterial,,,,20.0334,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,22.2995,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,25.8772,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x12 - R30 ins.,MasslessOpaqueMaterial,,,,26.8204,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,32.5111,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x14 - R38 ins.,MasslessOpaqueMaterial,,,,32.5111,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,9.54677,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,10.9003,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,12.1652,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x4 - R19 ins.,MasslessOpaqueMaterial,,,,14.4614,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,10.2668,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,11.8491,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x6 - R15 ins.,MasslessOpaqueMaterial,,,,13.359,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,16.1804,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,17.5004,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,17.0358,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Rafter Roof - 24inOC - 2x8 - R21 ins.,MasslessOpaqueMaterial,,,,18.5054,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 16inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,7.12596,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 16inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,7.70165,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 16inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,8.18665,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 16inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,11.7113,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 16inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,12.2507,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 16inOC - 2x6 - R22 ins.,MasslessOpaqueMaterial,,,,12.4993,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 16inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,13.4581,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 16inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,14.5092,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 16inOC - 2x8 - R25 ins.,MasslessOpaqueMaterial,,,,15.4247,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 16inOC - 2x8 - R30 ins.,MasslessOpaqueMaterial,,,,16.7137,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,7.44041,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x4 - R11 ins. AWS,MasslessOpaqueMaterial,,,,8.03106,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,8.09769,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x4 - R13 ins. AWS,MasslessOpaqueMaterial,,,,8.85675,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,8.6586,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x4 - R15 ins. AWS,MasslessOpaqueMaterial,,,,9.57897,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,12.2765,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x6 - R19 ins. AWS,MasslessOpaqueMaterial,,,,13.3502,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,12.8954,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x6 - R21 ins. AWS,MasslessOpaqueMaterial,,,,14.1353,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x6 - R22 ins.,MasslessOpaqueMaterial,,,,13.1824,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x6 - R22 ins. AWS,MasslessOpaqueMaterial,,,,14.5036,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,13.9462,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x8 - R19 ins. AWS,MasslessOpaqueMaterial,,,,14.8435,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,15.1272,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x8 - R22 ins. AWS,MasslessOpaqueMaterial,,,,16.2834,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x8 - R25 ins.,MasslessOpaqueMaterial,,,,16.1678,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x8 - R25 ins. AWS,MasslessOpaqueMaterial,,,,17.5793,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x8 - R30 ins.,MasslessOpaqueMaterial,,,,17.6518,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 24inOC - 2x8 - R30 ins. AWS,MasslessOpaqueMaterial,,,,19.4735,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 48inOC - 2x4 - R11 ins. AWS,MasslessOpaqueMaterial,,,,10.1197,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 48inOC - 2x4 - R13 ins. AWS,MasslessOpaqueMaterial,,,,11.711,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 48inOC - 2x4 - R15 ins. AWS,MasslessOpaqueMaterial,,,,13.2373,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 48inOC - 2x6 - R19 ins. AWS,MasslessOpaqueMaterial,,,,17.2794,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 48inOC - 2x6 - R21 ins. AWS,MasslessOpaqueMaterial,,,,18.8464,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 48inOC - 2x6 - R22 ins. AWS,MasslessOpaqueMaterial,,,,19.6146,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 48inOC - 2x8 - R19 ins. AWS,MasslessOpaqueMaterial,,,,17.8255,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 48inOC - 2x8 - R22 ins. AWS,MasslessOpaqueMaterial,,,,20.3213,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 48inOC - 2x8 - R25 ins. AWS,MasslessOpaqueMaterial,,,,22.7412,,,,,,,,,,,,,,,,,,,,,,, +Wood Framed Wall - 48inOC - 2x8 - R30 ins. AWS,MasslessOpaqueMaterial,,,,26.6149,,,,,,,,,,,,,,,,,,,,,,, +Wood shingles - 3/4 in.,StandardOpaqueMaterial,VeryRough,0.75,0.8304,0.903179191,36.94,0.31,,,,,,,,,,,,,,,,,,,,, +Wood shingles - plain and plastic film faced - 3/4 in.,StandardOpaqueMaterial,VeryRough,0.75,0.8004,0.937031484,22,0.31,,,,,,,,,,,,,,,,,,,,, +Wood Siding,StandardOpaqueMaterial,MediumSmooth,0.393700787,0.762681898,0.516205758,33.99951589,0.289003535,0.9,0.78,0.78,,,,,,,,,,,,,,,,,, +Wood siding - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,0.6204,0.805931657,36.94,0.28,,,,,,,,,,,,,,,,,,,,, +U 0.49 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.49,0.22,,,,,,,,,,,,,,, +U 0.57 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.57,0.25,,,,,,,,,,,,,,, +U 0.53 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.53,0.25,,,,,,,,,,,,,,, +U 0.48 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.48,0.25,,,,,,,,,,,,,,, +U 0.38 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.38,0.36,,,,,,,,,,,,,,, +U 0.38 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.38,0.38,,,,,,,,,,,,,,, +U 0.36 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.36,0.4,,,,,,,,,,,,,,, +U 0.33 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.33,0.45,,,,,,,,,,,,,,, +U 0.29 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.29,0.45,,,,,,,,,,,,,,, +U 0.5 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.22,,,,,,,,,,,,,,, +U 0.54 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.54,0.25,,,,,,,,,,,,,,, +U 0.49 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.49,0.25,,,,,,,,,,,,,,, +U 0.45 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.45,0.25,,,,,,,,,,,,,,, +U 1.19 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.19,0.45,,,,,,,,,,,,,,, +U 0.73 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.73,0.45,,,,,,,,,,,,,,, +U 0.62 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.62,0.45,,,,,,,,,,,,,,, +U 0.51 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.51,0.45,,,,,,,,,,,,,,, +U 0.38 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.38,0.45,,,,,,,,,,,,,,, +U 0.53 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.53,0.22,,,,,,,,,,,,,,, +U 0.53 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.53,0.23,,,,,,,,,,,,,,, +U 0.38 SHGC 0.35 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.38,0.35,,,,,,,,,,,,,,, +U 0.38 SHGC 0.37 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.38,0.37,,,,,,,,,,,,,,, +U 0.36 SHGC 0.37 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.36,0.37,,,,,,,,,,,,,,, +U 0.31 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.31,0.39,,,,,,,,,,,,,,, +U 0.28 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.28,0.39,,,,,,,,,,,,,,, +U 0.51 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.51,0.22,,,,,,,,,,,,,,, +U 0.51 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.51,0.23,,,,,,,,,,,,,,, +U 0.46 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.46,0.25,,,,,,,,,,,,,,, +U 0.43 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.43,0.25,,,,,,,,,,,,,,, +U 0.36 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.36,0.36,,,,,,,,,,,,,,, +U 0.36 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.36,0.38,,,,,,,,,,,,,,, +U 0.34 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.34,0.38,,,,,,,,,,,,,,, +U 0.29 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.29,0.4,,,,,,,,,,,,,,, +U 0.26 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.26,0.4,,,,,,,,,,,,,,, +U 0.37 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.37,0.36,,,,,,,,,,,,,,, +U 0.37 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.37,0.38,,,,,,,,,,,,,,, +U 0.35 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.35,0.38,,,,,,,,,,,,,,, +U 0.3 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.3,0.4,,,,,,,,,,,,,,, +U 0.27 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.27,0.4,,,,,,,,,,,,,,, +U 0.5 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.23,,,,,,,,,,,,,,, +U 0.42 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.42,0.25,,,,,,,,,,,,,,, +U 0.47 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.47,0.25,,,,,,,,,,,,,,, +U 1.2 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.2,0.45,,,,,,,,,,,,,,, +U 0.5 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.45,,,,,,,,,,,,,,, +U 0.39 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.39,0.45,,,,,,,,,,,,,,, +U 0.36 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.36,0.45,,,,,,,,,,,,,,, +U 0.75 SHGC 0.35 Simple Glazing Window,SimpleGlazing,,,,,,,,,,,0.75,0.35,,,,,,,,,,,,,,, +U 0.65 SHGC 0.35 Simple Glazing Window,SimpleGlazing,,,,,,,,,,,0.65,0.35,,,,,,,,,,,,,,, +U 0.55 SHGC 0.35 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.55,0.35,,,,,,,,,,,,,,, +U 0.5 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.4,,,,,,,,,,,,,,, +U 0.5 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.55,,,,,,,,,,,,,,, +U 0.41 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.41,0.55,,,,,,,,,,,,,,, +U 1.8 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.8,0.55,,,,,,,,,,,,,,, +U 1.7 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.7,0.55,,,,,,,,,,,,,,, +U 1.15 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.15,0.55,,,,,,,,,,,,,,, +U 0.98 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.55,,,,,,,,,,,,,,, +U 0.85 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.85,0.55,,,,,,,,,,,,,,, +U 0.7 SHGC 0.3 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.7,0.3,,,,,,,,,,,,,,, +U 0.65 SHGC 0.3 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.65,0.3,,,,,,,,,,,,,,, +U 0.55 SHGC 0.3 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.55,0.3,,,,,,,,,,,,,,, +U 0.47 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.47,0.4,,,,,,,,,,,,,,, +U 0.44 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.44,0.55,,,,,,,,,,,,,,, +U 0.9 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.9,0.55,,,,,,,,,,,,,,, +U 0.75 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.55,,,,,,,,,,,,,,, +U 0.37 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.37,0.25,,,,,,,,,,,,,,, +U 0.83 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.83,0.25,,,,,,,,,,,,,,, +U 0.77 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.77,0.25,,,,,,,,,,,,,,, +U 0.93 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.93,0.45,,,,,,,,,,,,,,, +U 0.83 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.83,0.45,,,,,,,,,,,,,,, +U 0.65 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.65,0.55,,,,,,,,,,,,,,, +U 1.8 SHGC 0.77 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.8,0.77,,,,,,,,,,,,,,, +U 0.65 SHGC 0.77 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.65,0.77,,,,,,,,,,,,,,, +U 0.65 SHGC 0.68 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.65,0.68,,,,,,,,,,,,,,, +U 1.8 SHGC 0.64 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.8,0.64,,,,,,,,,,,,,,, +U 0.33 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.33,0.25,,,,,,,,,,,,,,, +U 0.68 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.68,0.25,,,,,,,,,,,,,,, +U 0.87 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.87,0.45,,,,,,,,,,,,,,, +U 0.77 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.77,0.45,,,,,,,,,,,,,,, +U 0.55 SHGC 0.64 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.55,0.64,,,,,,,,,,,,,,, +U 0.55 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.55,0.55,,,,,,,,,,,,,,, +U 0.31 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.31,0.36,,,,,,,,,,,,,,, +U 0.68 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.68,0.36,,,,,,,,,,,,,,, +U 0.31 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.31,0.38,,,,,,,,,,,,,,, +U 0.68 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.68,0.38,,,,,,,,,,,,,,, +U 0.45 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.45,0.45,,,,,,,,,,,,,,, +U 0.5 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.36,,,,,,,,,,,,,,, +U 0.5 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.19,,,,,,,,,,,,,,, +U 0.5 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.34,,,,,,,,,,,,,,, +U 0.98 SHGC 0.27 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.27,,,,,,,,,,,,,,, +U 0.98 SHGC 0.36 Simple Glazing Weighted,SimpleGlazing,,,,,,,,,,,0.98,0.36,,,,,,,,,,,,,,, +U 0.68 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.68,0.4,,,,,,,,,,,,,,, +U 0.85 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.85,0.19,,,,,,,,,,,,,,, +U 0.85 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.85,0.39,,,,,,,,,,,,,,, +U 0.28 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.28,0.45,,,,,,,,,,,,,,, +U 0.68 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.68,0.45,,,,,,,,,,,,,,, +U 0.32 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.32,0.45,,,,,,,,,,,,,,, +U 0.5 SHGC 0.27 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.27,,,,,,,,,,,,,,, +U 0.25 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.25,0.45,,,,,,,,,,,,,,, +U 0.5 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.39,,,,,,,,,,,,,,, +U 0.5 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.65,,,,,,,,,,,,,,, +U 0.85 SHGC 0.27 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.85,0.27,,,,,,,,,,,,,,, +U 0.5 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.25,,,,,,,,,,,,,,, +U 1.1 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.1,0.25,,,,,,,,,,,,,,, +U 1.1 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.1,0.45,,,,,,,,,,,,,,, +U 0.75 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.49,,,,,,,,,,,,,,, +U 1.8 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.8,0.49,,,,,,,,,,,,,,, +U 0.75 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.39,,,,,,,,,,,,,,, +U 0.75 SHGC 0.68 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.68,,,,,,,,,,,,,,, +U 0.75 SHGC 0.64 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.64,,,,,,,,,,,,,,, +U 0.77 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.77,0.23,,,,,,,,,,,,,,, +U 0.68 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.68,0.23,,,,,,,,,,,,,,, +U 0.63 SHGC 0.33 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.63,0.33,,,,,,,,,,,,,,, +U 0.63 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.63,0.34,,,,,,,,,,,,,,, +U 0.63 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.63,0.36,,,,,,,,,,,,,,, +U 0.63 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.63,0.45,,,,,,,,,,,,,,, +U 0.83 SHGC 0.21 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.83,0.21,,,,,,,,,,,,,,, +U 0.32 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.32,0.22,,,,,,,,,,,,,,, +U 0.83 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.83,0.22,,,,,,,,,,,,,,, +U 0.83 SHGC 0.2 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.83,0.2,,,,,,,,,,,,,,, +U 0.6 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.6,0.23,,,,,,,,,,,,,,, +U 0.62 SHGC 0.2 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.62,0.2,,,,,,,,,,,,,,, +U 1.22 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.19,,,,,,,,,,,,,,, +U 1.22 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.45,,,,,,,,,,,,,,, +U 1.22 SHGC 0.17 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.17,,,,,,,,,,,,,,, +U 1.22 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.39,,,,,,,,,,,,,,, +U 0.98 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.45,,,,,,,,,,,,,,, +U 1.98 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.45,,,,,,,,,,,,,,, +U 0.57 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.57,0.39,,,,,,,,,,,,,,, +U 0.46 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.46,0.19,,,,,,,,,,,,,,, +U 1.98 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.34,,,,,,,,,,,,,,, +U 1.22 SHGC 0.61 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.61,,,,,,,,,,,,,,, +U 1.22 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.34,,,,,,,,,,,,,,, +U 0.57 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.57,0.49,,,,,,,,,,,,,,, +U 0.46 SHGC 0.26 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.46,0.26,,,,,,,,,,,,,,, +U 1.98 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.65,,,,,,,,,,,,,,, +U 0.58 SHGC 0.61 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.58,0.61,,,,,,,,,,,,,,, +U 0.46 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.46,0.36,,,,,,,,,,,,,,, +U 0.46 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.46,0.45,,,,,,,,,,,,,,, +U 0.35 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.35,0.45,,,,,,,,,,,,,,, +U 0.98 SHGC 0.62 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.62,,,,,,,,,,,,,,, +U 0.58 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.58,0.45,,,,,,,,,,,,,,, +U 0.75 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.25,,,,,,,,,,,,,,, +U 0.7 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.7,0.25,,,,,,,,,,,,,,, +U 1.98 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.49,,,,,,,,,,,,,,, +U 0.65 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.65,0.25,,,,,,,,,,,,,,, +U 0.6 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.6,0.25,,,,,,,,,,,,,,, +U 0.9 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.9,0.25,,,,,,,,,,,,,,, +U 1.98 SHGC 0.71 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.71,,,,,,,,,,,,,,, +U 0.4 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.4,0.4,,,,,,,,,,,,,,, +U 0.55 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.55,0.4,,,,,,,,,,,,,,, +U 0.85 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.85,0.4,,,,,,,,,,,,,,, +U 0.35 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.35,0.4,,,,,,,,,,,,,,, +U 0.45 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.45,0.4,,,,,,,,,,,,,,, +U 0.8 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.8,0.4,,,,,,,,,,,,,,, +U 0.65 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.65,0.45,,,,,,,,,,,,,,, +U 0.6 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.6,0.45,,,,,,,,,,,,,,, +U 0.9 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.9,0.45,,,,,,,,,,,,,,, +U 0.4 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.4,0.45,,,,,,,,,,,,,,, +U 0.8 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.8,0.45,,,,,,,,,,,,,,, +U 1.2 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.2,0.25,,,,,,,,,,,,,,, +U 1.98 SHGC 0.27 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.27,,,,,,,,,,,,,,, +U 1.17 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.17,0.45,,,,,,,,,,,,,,, +U 0.98 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.49,,,,,,,,,,,,,,, +U 0.98 SHGC 0.46 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.46,,,,,,,,,,,,,,, +U 0.58 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.58,0.65,,,,,,,,,,,,,,, +U 0.58 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.58,0.55,,,,,,,,,,,,,,, +U 0.4 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.4,0.25,,,,,,,,,,,,,,, +U 0.35 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.35,0.25,,,,,,,,,,,,,,, +U 0.55 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.55,0.45,,,,,,,,,,,,,,, +U 0.42 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.42,0.4,,,,,,,,,,,,,,, +U 0.77 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.77,0.4,,,,,,,,,,,,,,, +U 0.81 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.81,0.45,,,,,,,,,,,,,,, +U 0.32 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.32,0.4,,,,,,,,,,,,,,, +U 0.7 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.7,0.45,,,,,,,,,,,,,,, +U 0.59 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.59,0.45,,,,,,,,,,,,,,, +U 0.44 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.44,0.45,,,,,,,,,,,,,,, +U 0.93 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.93,0.25,,,,,,,,,,,,,,, +U 0.75 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.45,,,,,,,,,,,,,,, +U 0.48 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.48,0.45,,,,,,,,,,,,,,, diff --git a/data/openstudio_standards_data/database_files/support_performance_curves.csv b/data/openstudio_standards_data/database_files/support_performance_curves.csv new file mode 100644 index 0000000000..831e7d15c5 --- /dev/null +++ b/data/openstudio_standards_data/database_files/support_performance_curves.csv @@ -0,0 +1,734 @@ +name,category,form,dependent_variable,independent_variable_1,independent_variable_2,coeff_1,coeff_2,coeff_3,coeff_4,coeff_5,coeff_6,coeff_7,coeff_8,coeff_9,coeff_10,minimum_independent_variable_1,maximum_independent_variable_1,minimum_independent_variable_2,maximum_independent_variable_2,minimum_dependent_variable_output,maximum_dependent_variable_output,annotation +a-Si_Spectral-fAirMass,PV-Module,Cubic,,AirMass,,0.99264449,0.05334853,-0.0372019,0.00327026,,,,,,,,,,,,,From .dat files included with MASControl2 +Absor-1-Cap-fCHWT&ECT,1-StageAbsorptn,BiQuadratic,QRatio,CHWT,ECT,1.757428,0.054774,-0.00290628,-0.035145,-0.000156,0.000894,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Absor-1-HIR-fCHWT&ECT,1-StageAbsorptn,BiQuadratic,,CHWT,ECT,0.691153,0,0,0.005355,0.000178,0,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Absor-1-HIR-fPLR,1-StageAbsorptn,Quadratic,,PLR,,0.087773,0.744921,0.167306,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Absor-2-Cap-fCHWT&ECT,2-StageAbsorptn,BiQuadratic,QRatio,CHWT,ECT,0.362073,0.0001386,0.001458,0.0733878,-0.00206064,0.00101,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Absor-2-HIR-fCHWT&ECT,2-StageAbsorptn,BiQuadratic,,CHWT,ECT,0.98675,0,0,-0.0234,0.00081,0,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Absor-2-HIR-fPLR,2-StageAbsorptn,Quadratic,,PLR,,0.1355115,0.61798084,0.24651277,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +AHU-1_CoolCStandard10Ton_CapFF,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.77136,0.34053,-0.11088,,,,,,,,0.75918,1.13877,,,,,"From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" +AirCooled_Chiller_2004_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.0433811,0.0407077,0.0004506,-0.0041514,-0.0000886,-0.0003467,,,,,5,10,12.7,51.67,,,"Based on Dick Lord's study dated January 17, 2010." +AirCooled_Chiller_2004_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.5961915,-0.0099496,0.0007888,0.0004506,0.0004875,-0.0007623,,,,,5,10,12.7,51.67,,,"Based on Dick Lord's study dated January 17, 2010." +AirCooled_Chiller_2010_PathA_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.0433825,0.0407073,0.0004506,-0.0041514,-0.0000886,-0.0003467,,,,,5,10,12.7,51.67,,,"Based on Dick Lord's study dated January 17, 2010." +AirCooled_Chiller_2010_PathA_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.5961915,-0.0099496,0.0007888,0.0004506,0.0004875,-0.0007623,,,,,5,10,12.7,51.67,,,"Based on Dick Lord's study dated January 17, 2010." +AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.141,0.655,0.203,,,,,,,,0,1,,,,,"Based on Dick Lord's study dated January 17, 2010. EIRFPLR curve is identical for all AirCooled Chillers" +AirCooled_Chiller_GT150_2004_EIRFPLR,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.141,0.655,0.203,,,,,,,,0,1,,,,,"Based on Dick Lord's study dated January 17, 2010." +AirCooled_Chiller_GT150_2010_PathA_EIRFPLR,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.141,0.655,0.203,,,,,,,,0,1,,,,,"Based on Dick Lord's study dated January 17, 2010." +AirCooled_Chiller_LT150_2004_EIRFPLR,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.141,0.655,0.203,,,,,,,,0,1,,,,,"Based on Dick Lord's study dated January 17, 2010." +AirCooled_Chiller_LT150_2010_PathA_EIRFPLR,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.141,0.655,0.203,,,,,,,,0,1,,,,,"Based on Dick Lord's study dated January 17, 2010." +AirFoil w Dischrg Dampers FPLR,FanEIR-FPLR,Quadratic,,PLR,,0.227143,1.178929,-0.410714,,,,,,,,,,,,0.68,1,From .dat files included with MASControl2 +AirFoil w Inlet Vanes FPLR,FanEIR-FPLR,Quadratic,,PLR,,0.584345,-0.579167,0.970238,,,,,,,,,,,,0.48,1,From .dat files included with MASControl2 +Atmospheric-Blr-HIR-fPLR,FuelBoilers,Quadratic,,PLR,,0.02699999,1.10549998,-0.13249961,,,,,,,,,,,,,,From .dat files included with MASControl2 +Boiler Constant Efficiency Curve,Boiler,Cubic,FIRRatio,QRatio,,1,0,0,0,,,,,,,0,1,,,,,From DOE Reference Building +Boiler with Minimum Turndown,Boiler,Cubic,FIRRatio,QRatio,,0.7791,1.4745,-2.5795,1.3467,,,,,,,0,1.3,,,,,From Regression of Prototype Building EMS +Boiler with No Minimum Turndown,Boiler,Cubic,FIRRatio,QRatio,,0.7463,1.3196,-2.2154,1.1674,,,,,,,0,1.3,,,,,From Regression of Prototype Building EMS +BOILER-EFFFPLR-NECB2011,Boiler,Cubic,FIRRatio,QRatio,,0.2901,2.6664,-3.764,1.82,,,,,,,0,1,,,,,From NECB 2011 +CdTe_Spectral-fAirMass,PV-Module,Cubic,,AirMass,,0.93700588,0.05130703,-0.00646639,0.00017267,,,,,,,,,,,,,From .dat files included with MASControl2 +CentChlrAirCoolCap-fCHW&OAT,Chiller,BiQuadratic,QRatio,CHWT,OAT,0.94533053,0.068473818,-0.003361694,0.000108108,-0.000225,0.000082,,,,,,,,,,,From .dat files included with MASControl2 +CentChlrAirCoolEIR-fCHW&OAT,Chiller,BiQuadratic,EIRRatio,CHWT,OAT,0.47343824,0.015708042,-0.000948,0.012260718,0.0000955,-0.000352,,,,,,,,,,,From .dat files included with MASControl2 +CentChlrAirCoolEIR-fPLR,Chiller,Quadratic,EIRRatio,PLR,,0.24258,0.41468,0.34273973,,,,,,,,,,,,,,From .dat files included with MASControl2 +CentH2O-Cap-fCHWT&ECT,HermCentrifugal,BiQuadratic,QRatio,CHWT,ECT,0.36460761,-0.030523554,-0.001929776,0.066367926,-0.001891966,0.003110627,,,,,,,,,,,From .dat files included with MASControl2 +CentH2O-EIR-fCHWT&ECT,HermCentrifugal,BiQuadratic,EIRRatio,CHWT,ECT,0.65868459,-0.025336458,0.000991,0.01280322,0.000171,-0.000301,,,,,,,,,,,From .dat files included with MASControl2 +CentH2O-EIR-fPLR&dT,HermCentrifugal,BiQuadratic,EIRRatio,PLR,dT,0.27969646,0.57375735,0.25690463,-0.010452906,0.000475,-0.006354126,,,,,,,,,,,From .dat files included with MASControl2 +CentH2OVSD-Cap-fCHWT&ECT,HermCentrifugal,BiQuadratic,QRatio,CHWT,ECT,0.36211013,-0.032249754,-0.000886,0.066743838,-0.001731488,0.002180358,,,,,,,,,,,From .dat files included with MASControl2 +CentH2OVSD-EIR-fCHWT&ECT,HermCentrifugal,BiQuadratic,EIRRatio,CHWT,ECT,0.41386133,-0.088037676,0.00098,0.056770308,-0.000946,0.001418731,,,,,,,,,,,From .dat files included with MASControl2 +CentH2OVSD-EIR-fPLR&dT,HermCentrifugal,BiQuadratic,EIRRatio,PLR,dT,0.14703037,-0.00349667,1.01161313,-0.006474546,0.00088,-0.020960478,,,,,,,,,,,From .dat files included with MASControl2 +ChillerCentCapFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.7446451,0.0114858,0.0000148,0.022401,-0.000688,0.0009839,,,,,5,10,24,35,,,From Dick Lord's Chiller Model study for ASHRAE 2007 baseline +ChillerCentEIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.772877,0.022101,-0.0000799,-0.0070045,0.0004763,-0.0010612,,,,,5,10,24,35,,,From Dick Lord's Chiller Model study for ASHRAE 2007 baseline +ChillerCentEIRPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,From Dick Lord's Chiller Model study for ASHRAE 2007 baseline +ChlrAirRecipEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.114437,0.545933,0.342299,,,,,,,,0,1,,,0.11,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrAirRecipEIRRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.542784,-0.013907,0.000476,0.012197,0.000149,-0.000334,,,,,4.44,12.22,23.89,46.11,0.72,1.3,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrAirRecipQRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.12603,0.041571,0.000253,-0.010526,0.00001,-0.000256,,,,,4.44,12.22,23.89,46.11,0.82,1.3,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrAirScrewEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.036487,0.734743,0.219947,,,,,,,,0,1,,,0.04,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrAirScrewEIRRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.570624,0.011954,-0.000522,-0.000032,0.000421,-0.000606,,,,,4.44,12.22,23.89,46.11,0.7,1.38,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrAirScrewQRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.985959,0.049487,-0.000298,-0.003737,-0.000045,-0.000502,,,,,4.44,12.22,23.89,46.11,0.82,1.3,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrAirScrollEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.063691,0.584888,0.352803,,,,,,,,0,1,,,0.06,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrAirScrollEIRRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.702194,-0.004466,0.000535,-0.005506,0.000544,-0.000729,,,,,4.44,12.22,23.89,46.11,0.69,1.45,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrAirScrollQRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.02138,0.037021,0.000233,-0.003893,-0.000065,-0.000269,,,,,4.44,12.22,23.89,46.11,0.82,1.3,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrHPAirCoolCap-fCHW&OAT,Chiller,BiQuadratic,QRatio,CHWT,OAT,1.13076899,0.03157983,0.000358,-0.009856332,0.0000101,-0.00015,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPAirCoolEIR-fCHW&OAT,Chiller,BiQuadratic,EIRRatio,CHWT,OAT,0.5637406,-0.009225918,0.000353,0.009452178,0.000187,-0.000314,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPAirHeatCap-fHW&39-,Chiller,BiQuadratic,QRatio,HW,39,0.92141508,-0.003413682,-0.00000386,0.0324,0.000611,-0.0000518,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPAirHeatCap-fHW&39+,Chiller,BiQuadratic,QRatio,HW,39+,0.94069023,-0.004035888,0.000000421,0.046218906,-0.001703171,-0.000000227,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPAirHeatEIR-fHW&39-,Chiller,BiQuadratic,EIRRatio,HW,39,0.33398382,0.019817694,0.000012,0.0048024,-0.0000332,-0.000898,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPAirHeatEIR-fHW&39+,Chiller,BiQuadratic,EIRRatio,HW,39+,0.38886863,0.018107262,0.0000194,-0.026683668,0.002056655,-0.000499,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPH2OCoolCap_fCHW&ECT,Chiller/HP,BiQuadratic,QRatio,CHWT,ECT,35.68362061,0.62273101,-0.005677932,-0.248948775,-0.003461286,0.011142622,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPH2OCoolCap_fCHW&ECT-Old,Chiller/HP,BiQuadratic,QRatio,CHWT,ECT,0.96601399,0.04050054,0.000589,-0.008098668,0.0000665,-0.000454,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPH2OCoolEIR_fCHW&ECT,Chiller/HP,BiQuadratic,EIRRatio,CHWT,ECT,0.111287472,-0.002094557,0.000201,0.00170532,0.000168,-0.000308,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPH2OCoolEIR_fCHW&ECT-Old,Chiller/HP,BiQuadratic,EIRRatio,CHWT,ECT,0.61092869,-0.016352352,0.000407,0.003044232,0.000592,-0.000668,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPH2OHeatCap_fHWS&EET,Chiller/HP,BiQuadratic,QRatio,HWS,EET,29.914016,0.1544256,-0.0041472,0.6832512,-0.00203148,0.00199584,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPH2OHeatCap_fHWS&EET-Old,Chiller/HP,BiQuadratic,QRatio,HWS,EET,0.84649612,-0.00264807,0.0000231,0.02700126,0.00013,-0.000127,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPH2OHeatEIR_fHWS&EET,Chiller/HP,BiQuadratic,EIRRatio,HWS,EET,0.12004,-0.00011232,0.0000985,-0.00107928,0.0000732,-0.000134,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPH2OHeatEIR_fHWS&EET-Old,Chiller/HP,BiQuadratic,EIRRatio,HWS,EET,0.2068226,0.018812142,0.000105,-0.012659724,0.000406,-0.000399,,,,,,,,,,,From .dat files included with MASControl2 +ChlrWtrCentPathAAllEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.222149,0.503156,0.256905,,,,,,,,0.1,1,,,0.28,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrCentPathAAllEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.658643,-0.025339,0.000991,0.012801,0.000171,-0.000301,,,,,4.44,12.22,15.56,29.44,0.68,1.05,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrCentPathAAllQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.364691,-0.030521,-0.00193,0.066374,-0.001892,0.003111,,,,,4.44,12.22,15.56,29.44,0.87,0.91,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrCentPathBGtEql300Lt600tonEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.055483,0.451866,0.488242,,,,,,,,0.1,1,,,0.11,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrCentPathBGtEql300Lt600tonEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.756376,-0.015019,0.000156,0.00246,0.000515,-0.000687,,,,,4.44,12.22,15.56,29.44,0.63,1.12,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrCentPathBGtEql300Lt600tonQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,1.35608,0.04875,-0.000888,-0.014525,-0.000286,-0.00004,,,,,4.44,12.22,15.56,29.44,0.87,1.52,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrCentPathBGtEql600tonEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.107426,0.156775,0.739345,,,,,,,,0.1,1,,,0.13,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrCentPathBGtEql600tonEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.737625,0.001456,-0.000223,0.007116,0.000267,-0.000735,,,,,4.44,12.22,15.56,29.44,0.76,1.08,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrCentPathBGtEql600tonQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.854454,0.042526,-0.000185,0.011697,-0.000497,-0.000412,,,,,4.44,12.22,15.56,29.44,0.9,1.33,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrCentPathBLt300tonEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.208389,-0.121404,0.918455,,,,,,,,0.1,1,,,0.21,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrCentPathBLt300tonEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.711108,-0.023515,0.001194,0.017737,0.000152,-0.001159,,,,,4.44,12.22,15.56,29.44,0.69,1.13,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrCentPathBLt300tonQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,1.15508,0.036503,-0.000499,-0.001455,-0.000439,-0.000172,,,,,4.44,12.22,15.56,29.44,0.86,1.37,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.310965,0.322519,0.372745,,,,,,,,0.1,1,,,0.35,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.665307,-0.009339,0.000483,0.009492,0.000544,-0.000864,,,,,4.44,12.22,15.56,29.44,0.74,1.27,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.96744,0.037082,0.000434,-0.005837,-0.000049,-0.000274,,,,,4.44,12.22,15.56,29.44,0.89,1.33,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrPosDispPathBAllEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0,0.6206,0.3893,,,,,,,,0.1,1,,,0.07,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrPosDispPathBAllEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.428265,-0.024071,0.000849,0.016416,0.000381,-0.00059,,,,,4.44,12.22,15.56,29.44,0.5,1.07,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrPosDispPathBAllQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.899926,0.030102,-0.000332,-0.001743,-0.000092,0.000229,,,,,4.44,12.22,15.56,29.44,0.93,1.21,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CHW-Coil-Cap-fAirflow,CHWCoils,Quadratic,QRatio,Airflow,,0.0488,1.38,-0.425,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +CHW-Coil-Cap-fEWB&EWT,CHWCoils,BiQuadratic,QRatio,EWB,EWT,1.6726784,-0.13378464,0.0065124,0.03828096,0.0000826,-0.005868936,,,,,15.55556,29.44444,4.44444,18.33333,,,From .dat files included with MASControl2 +CHW-Coil-Cap-fFluidFlow,CHWCoils,Quadratic,QRatio,FluidFlow,,0.218,3199.5088,-3280000,,,,,,,,0,1,,,,,From .dat files included with MASControl2 +Coffin Defrost Curve,Refrigerated Case,Cubic,,,,0.3475,0.0296,0.0007,0.00003,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings +Coffin Latent Curve,Refrigerated Case,Cubic,,,,0.3379,0.0309,0.0005,0.00004,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings +COIL-BF-FFLOW-SPEC,CoilBF-FFLOW,Linear,,Flow,,0.33,1419.6496,,,,,,,,,,,,,0.8,,From .dat files included with MASControl2 +Coil-Bypass-Factor-fPLR,CHWCoils,Linear,QRatio,PLR,,1,0,,,,,,,,,,,,,,,From .dat files included with MASControl2 +CoilClgDXDblEIRRatio_fCFMRatio,DX Cooling Coil,Cubic,EIRRatio,FlowRatio,,1.007948,0.345441,-0.692289,0.338899,,,,,,,0,1,,,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgDXDblQRatio_fCFMRatio,DX Cooling Coil,Cubic,QRatio,FlowRatio,,0.472786,1.243342,-1.038706,0.322578,,,,,,,-100,100,0.47,,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgDXEIRRatio_fQFrac,DX Cooling Coil,Cubic,EIRRatio,QRatio,,0,5.1091,-8.5515,4.4744,,,,,,,0.7,1,0.92,1,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgDXEIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.116709,0.028458,-0.000411,0.021422,0.000162,-0.00068,,,,,13.89,25,23.89,46.11,0.77,1.33,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgDXQRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.86779,0.014245,0.000554,-0.007569,0.000032,-0.000191,,,,,13.89,25,23.89,46.11,0.77,1.29,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgDXSEER13EER11EIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,-0.199992,-0.035686,0.000787,0.074834,-0.000516,-0.000573,,,,,13.89,25,23.89,46.11,0.55,1.44,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgDXSEER15EER11EIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,-1.790474,-0.028777,0.000763,0.153391,-0.001482,-0.000721,,,,,13.89,25,23.89,46.11,0.35,1.42,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgDXSEER16EER13EIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.686684,-0.035826,0.000781,0.025564,0.000163,-0.000559,,,,,13.89,25,23.89,46.11,0.65,1.51,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgDXSEER17EER11EIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,-3.060538,-0.023207,0.000744,0.216093,-0.002253,-0.000839,,,,,13.89,25,23.89,46.11,0.2,1.4,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgDXSEER18EER13EIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,-1.247121,-0.027513,0.000752,0.121123,-0.001013,-0.000736,,,,,13.89,25,23.89,46.11,0.41,1.48,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgDXSEER20EER13EIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,-2.72492,-0.02112,0.00073,0.194128,-0.001911,-0.000872,,,,,13.89,25,23.89,46.11,0.23,1.45,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgDXSEEREIRRatio_fQFrac,DX Cooling Coil,Cubic,EIRRatio,QRatio,,1,0,0,0,,,,,,,0.7,1,1,1,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgDXSnglEIRRatio_fCFMRatio,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.156,-0.1816,0.0256,,,,,,,,0,1,,,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgDXSnglQRatio_fCFMRatio,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgPTACEIRRatio_fQFrac,DX Cooling Coil,Cubic,EIRRatio,QRatio,,0.85,0.15,0,0,,,,,,,0.7,1,0.96,1,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgPTACEIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.341434,0.03481,-0.000625,0.004941,0.000437,-0.000729,,,,,13.89,25,23.89,46.11,0.75,1.4,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgPTACQRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.942879,0.009538,0.000684,-0.011002,0.000006,-0.00001,,,,,13.89,25,23.89,46.11,0.71,1.34,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ConstantCubic,,Cubic,,,,1,0,0,0,,,,,,,-100,100,,,,,From Reference Buildings +Cool-PLF-fPLR,DX Cooling Coil,Quadratic,EIRRatio,QRatio,,0.90949556,0.09864773,-0.00819488,,,,,,,,0,1,,,,,From PNNL Prototype FullServiceRestaurant +CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.2055,-0.32953,0.12308,,,,,,,,0.75918,1.13877,,,,,"From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" +Curve_Biquadratic_CBES_01,,BiQuadratic,,,,0.86779,0.014245,0.000554,-0.007569,0.000032,-0.000191,,,,,0,100,0,100,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov +Curve_Biquadratic_CBES_02,,BiQuadratic,,,,-0.199992,-0.035686,0.000787,0.074834,-0.000516,-0.000573,,,,,13.9,25,23.9,43.3,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov +Curve_Biquadratic_CBES_03,,BiQuadratic,,,,0.9425878,0.00954335,0.00068377,-0.0110427,0.00000525,-0.00000972,,,,,17,22,13,46,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov +Curve_Biquadratic_CBES_04,,BiQuadratic,,,,0.3424144,0.03488501,-0.0006237,0.00497722,0.00043795,-0.000728,,,,,17,22,13,46,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov +Curve_Quadratic_CBES_01,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov +Curve_Quadratic_CBES_02,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.156,-0.1816,0.0256,,,,,,,,0.5,1.5,,,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov +Curve_Quadratic_CBES_03,,Quadratic,,,,1,0,0,,,,,,,,0,1,,,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov +Curve_Quadratic_CBES_04,,Quadratic,,,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov +Curve_Quadratic_CBES_05,,Quadratic,,,,1.1552,-0.1808,0.0256,,,,,,,,0.5,1.5,,,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov +Curve_Quadratic_CBES_06,,Quadratic,,,,0.85,0.15,0,,,,,,,,0,1,,,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov +DEER DHW HIR-FPLR Curve,DEERDHWHIR-FPLR,Linear,,PLR,,0,1,,,,,,,,,,,,,,,From .dat files included with MASControl2 +DEER_defrost,Refrigeration,Cubic,,,,0.023632,0.0006232,0.00002832,4.4035E-07,,,,,,,-23,7,,,,, +DEER_Heat_Rejections_LT,Refrigeration,Linear,Capacity,DeltaT,,0,16383.61446,,,,,,,,,-100,100,,,,,From eQuest Grocery store model +DEER_Heat_Rejections_MT,Refrigeration,Linear,Capacity,DeltaT,,0,20626.34211,,,,,,,,,-100,100,,,,,From eQuest Grocery store model +Default_Case_Latent_Cedit_Curve,Refrigeration,Cubic,,,,0.026526281,0.001078032,-6.02558E-05,1.23732E-06,,,,,,,-35,20,,,,, +Defrost-ResisDem-Frac-fOWB&ODB,DXCool/Heat,BiLinear,QRatio,OWB,ODB,0.0333,0,0,,,,,,,,-23.333,29.444,-23.333,29.444,,,From .dat files included with MASControl2 +Defrost-ResisTime-Frac-fOWB&ODB,DXCool/Heat,BiLinear,QRatio,OWB,ODB,0.0333,0,0,,,,,,,,-23.333,29.444,-23.333,29.444,,,From .dat files included with MASControl2 +Defrost-ReversDem-Frac-fOWB&ODB,DXCool/Heat,BiLinear,QRatio,OWB,ODB,0.0333,0,0,,,,,,,,-23.333,29.444,-23.333,29.444,,,From .dat files included with MASControl2 +Defrost-ReversTime-Frac-fOWB&ODB,DXCool/Heat,BiLinear,QRatio,OWB,ODB,0.0583,0,0,,,,,,,,-23.333,29.444,-23.333,29.444,,,From .dat files included with MASControl2 +Desc-Gas-fT&W,Desiccant,BiQuadratic,,T,W,18784.36736,-3209.524992,-11.8830564,3874.59,-1.69627,-23.53176,,,,,7.22222,46.11111,0,0.1,,,From .dat files included with MASControl2 +Desc-HR8-fWB1&WB6,Desiccant,BiQuadratic,,WB1,WB6,-0.27680768,0.071770464,0.000735,0.145668672,0.000591,-0.002648246,,,,,12.77778,46.11111,12.77778,46.11111,,,From .dat files included with MASControl2 +Desc-HR8PL-fWB1&WB6,Desiccant,BiQuadratic,,WB1,WB6,-0.05234208,0.076111488,0.000502,0.11464641,0.001235315,-0.002453879,,,,,12.77778,46.11111,12.77778,46.11111,,,From .dat files included with MASControl2 +Desc-kW-fT&W,Desiccant,BiQuadratic,,T,W,3.33024,-0.010674,0,0.00404,0,0,,,,,7.22222,46.11111,0,0.1,,,From .dat files included with MASControl2 +Desc-QREG-fWB1&WB6,Desiccant,BiQuadratic,,WB1,WB6,80.58068736,-0.627217344,0.0170748,-2.186211312,0.0000437,0.018960674,,,,,12.77778,40.55556,12.77778,46.11111,,,From .dat files included with MASControl2 +Desc-QREGPL-fWB1&WB6,Desiccant,BiQuadratic,,WB1,WB6,20.30901408,-0.159663744,0.0046008,-0.586622934,-0.00024,0.005206064,,,,,12.77778,46.11111,12.77778,46.11111,,,From .dat files included with MASControl2 +Desc-T-fT&W,Desiccant,BiQuadratic,,T,W,31.53328,1.0173168,-0.0033372,0.295,-0.00017,-0.0015696,,,,,7.22222,46.11111,0,0.1,,,From .dat files included with MASControl2 +Desc-T8-fWB1&WB6,Desiccant,BiLinear,,WB1,WB6,34.64,1.6236,0.2574,,,,,,,,12.77778,46.11111,12.77778,46.11111,,,From .dat files included with MASControl2 +Desc-T8PL-fWB1&WB6,Desiccant,BiLinear,,WB1,WB6,32.7692,1.7496,0.06588,,,,,,,,12.77778,46.11111,12.77778,46.11111,,,From .dat files included with MASControl2 +Desc-W-fT&W,Desiccant,BiQuadratic,,T,W,7.82704,0.119376,0.0144504,0.0831,0.000697,0.002862,,,,,7.22222,46.11111,0,0.1,,,From .dat files included with MASControl2 +Direct-Effectiveness-fFlow,EvapCooler,Quadratic,,Flow,,1.18,-546.67104,333000,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +DOE Ref DX Clg Coil Cool-CAP-fFlow,DX Cooling Coil,Cubic,QRatio,FlowRatio,,1,0,0,0,,,,,,,-100,100,,,,,From DOE Pre-1980 Reference Building +DOE Ref DX Clg Coil Cool-Cap-fT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.9712123,-0.015275502,0.001443452,-0.00039321,-6.8364E-06,-0.000290596,,,,,-100,100,-100,100,,,From DOE Pre-1980 Reference Building +DOE Ref DX Clg Coil Cool-EIR-fFlow,DX Cooling Coil,Cubic,EIRRatio,FlowRatio,,1,0,0,0,,,,,,,-100,100,,,,,From DOE Pre-1980 Reference Building +DOE Ref DX Clg Coil Cool-EIR-fT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.28687133,0.023902164,-0.000810648,0.013458546,0.000338936,-0.000487004,,,,,-100,100,-100,100,,,From DOE Pre-1980 Reference Building +DOE Ref DX Clg Coil Cool-PLF-fPLR,DX Cooling Coil,Quadratic,EIRRatio,QRatio,,0.90949556,0.09864773,-0.00819488,,,,,,,,0,1,,,,, +Draft-Fan-EIR-fPLR,FuelBoilers,Cubic,EIRRatio,PLR,,0.35071223,0.3080535,-0.5413736,0.87198823,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +DW-Elec-EIR-fPLR,ElecDW-Heater,Linear,EIRRatio,PLR,,0,1,,,,,,,,,,,,,,,From .dat files included with MASControl2 +DW-Gas-HIR-fPLR,GasDW-Heater,Quadratic,,PLR,,0.021826,0.97763,0.000543,,,,,,,,,,,,,,From .dat files included with MASControl2 +DW-Gas-Pilotless-HIR-fPLR,GasDW-Heater,Quadratic,,PLR,,0,0.999457,0.000543,,,,,,,,,,,,,,From .dat files included with MASControl2 +DW-HeatPump-Cap-fSupplyT&EDB,HeatPumpDW-Heat,BiQuadratic,QRatio,SupplyT,EDB,0.74922298,0,0,0.028130328,0.000236,0,,,,,,,,,,,From .dat files included with MASControl2 +DW-HeatPump-EIR-fPLR,HeatPumpDW-Heat,Cubic,EIRRatio,PLR,,0.08565215,0.93881371,-0.1834361,0.15897022,,,,,,,,,,,,,From .dat files included with MASControl2 +DW-HeatPump-EIR-fSupplyT&EDB,HeatPumpDW-Heat,BiQuadratic,EIRRatio,SupplyT,EDB,1.25311702,0,0,-0.033921486,0.000426,0,,,,,,,,,,,From .dat files included with MASControl2 +DX Coil Cap-FF,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,,"From PNNL Prototype Buildings ApartmentMidRise, HotelSmall, OfficeSmall, RetailStandAlone, RetailStripmall, SchoolPrimary, Warehouse" +DX-Bypass-Factor-fAirflow,DXCool/Heat,Quadratic,QRatio,Airflow,,-0.2542341,1.2182557,0.03597841,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +DX-Bypass-Factor-fEWB&EDB,DXCool/Heat,BiQuadratic,QRatio,EWB,EDB,0.8463094,0.014259096,0.000184,-0.014791716,-0.00000548,0.000487,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +DX-Bypass-Factor-fPLR,DXCool/Heat,Linear,QRatio,PLR,,1,0,,,,,,,,,,,,,,,From .dat files included with MASControl2 +DX-Cap-fAirflow,DXCool/Heat,Cubic,QRatio,Airflow,,0.06429396,1.99755645,-1.44277024,0.38091758,,,,,,,,,,,,,From .dat files included with MASControl2 +DX-Cool-Cap-fEWB&OAT,DXCool/Heat,BiQuadratic,QRatio,EWB,OAT,0.86791562,0.014247648,0.000554,-0.007558056,0.000033,-0.000192,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +DX-Cool-Cap-fRPM&OAT,DXCool/Heat,BiQuadratic,QRatio,RPM,OAT,32,9.549296596,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 +DX-Cool-CondFan-fPLR&OAT,DXCool/Heat,BiQuadratic,PwrRatio,PLR,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 +DX-Cool-CycleLoss-fPLR,DXCool/Heat,Linear,QRatio,PLR,,0.7,0.3,,,,,,,,,,,,,,,From .dat files included with MASControl2 +DX-Cool-EIR-fEWB&OAT,DXCool/Heat,BiQuadratic,EIRRatio,EWB,OAT,0.1210048,0.0285336,-0.000411,0.02134944,0.000161,-0.00068,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +DX-Cool-EIR-fPLR,DXCool/Heat,Cubic,EIRRatio,PLR,,0.201,-0.0312,1.95,-1.12,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +DX-Cool-EIR-fRPM&OAT,DXCool/Heat,BiQuadratic,EIRRatio,RPM,OAT,32,9.549296596,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 +DX-Cool-Waste-Heat-fEWB&OAT,DXCool/Heat,BiLinear,QRatio,EWB,OAT,1,0,0,,,,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +DX-Cool-Waste-Heat-fRPM&OAT,DXCool/Heat,BiQuadratic,QRatio,RPM,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 +DX-Heat-Cap-fEDB&OAT,DXCool/Heat,BiQuadratic,QRatio,EDB,OAT,0.7422592,0,0,0.030682602,0.0000323,0,,,,,12.77778,29.44444,-12.22222,29.44444,,,From .dat files included with MASControl2 +DX-Heat-Cap-fRPM&OAT,DXCool/Heat,BiQuadratic,QRatio,RPM,OAT,32,9.549296596,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 +DX-Heat-CondFan-fPLR&OAT,DXCool/Heat,BiQuadratic,PwrRatio,PLR,OAT,1,0,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 +DX-Heat-CycleLoss-fPLR,DXCool/Heat,Linear,QRatio,PLR,,0.75,0.25,,,,,,,,,,,,,,,From .dat files included with MASControl2 +DX-Heat-EIR-fEDB&OAT,DXCool/Heat,BiQuadratic,EIRRatio,EDB,OAT,1.25399584,0,0,-0.040063338,0.0010877,0,,,,,12.77778,29.44444,-12.22222,29.44444,,,From .dat files included with MASControl2 +DX-Heat-EIR-fPLR,DXCool/Heat,Cubic,EIRRatio,PLR,,0.0857,0.939,-0.183,0.159,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +DX-Heat-EIR-fRPM&OAT,DXCool/Heat,BiQuadratic,EIRRatio,RPM,OAT,32,9.549296596,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 +DX-Heat-Waste-Heat-fEDB&OAT,DXCool/Heat,BiLinear,QRatio,EDB,OAT,1,0,0,,,,,,,,12.77778,29.44444,-12.22222,29.44444,,,From .dat files included with MASControl2 +DX-Heat-Waste-Heat-fRPM&OAT,DXCool/Heat,BiQuadratic,QRatio,RPM,OAT,1,0,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 +DX-Sens-Cap-fAirflow,DXCool/Heat,Cubic,QRatio,Airflow,,0.34465606,0.89289891,-0.3554498,0.1178948,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +DX-Sens-Cap-fEWB&OAT,DXCool/Heat,BiQuadratic,QRatio,EWB,OAT,2.93224448,-0.09445968,0.0002,-0.007176816,0.0000103,0.000109,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +DXCOOL-NECB2011-REF-CAPFFLOW,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,1,0,0,,,,,,,,0,1,,,,,From NECB 2011 +DXCOOL-NECB2011-REF-CAPFT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.867905,0.0142459,0.00055436,-0.0075575,0.000033,-0.0001918,,,,,13,24,24,46,,,From NECB 2011 +DXCOOL-NECB2011-REF-COOLEIRFFLOW,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1,0,0,,,,,,,,0,1,,,,,From NECB 2011 +DXCOOL-NECB2011-REF-COOLEIRFT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.116936,0.0284933,-0.0004112,0.0214108,0.00016103,-0.0006791,,,,,13,24,24,46,,,From NECB 2011 +DXCOOL-NECB2011-REF-COOLPLFFPLR,DX Cooling Coil,Cubic,EIRRatio,QRatio,,0.0277,4.9151,-8.184,4.2702,,,,,,,0.7,1,,,,,"From NECB, curve modified to take into account how PLF is used in E+, and PLF ranges (> 0.7)" +DXHEAT-NECB2011-REF-CAPFFLOW,DX Heating Coil,Cubic,QRatio,FlowRatio,,0.84,0.16,0,0,,,,,,,0.5,1.5,,,,,From NECB 2011 +DXHEAT-NECB2011-REF-CAPFT,DX Heating Coil,Cubic,QRatio,Toadb,,0.729,0.0319,0.000136,-0.00000875,,,,,,,-20,20,,,,,From NECB 2011 +DXHEAT-NECB2011-REF-EIRFFLOW,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.3824,-0.4336,0.0512,,,,,,,,0,1,,,,,From NECB 2011 +DXHEAT-NECB2011-REF-EIRFT,DX Heating Coil,Cubic,EIRRatio,Toadb,,1.2183,-0.03612,0.00142,-0.0000268,,,,,,,-20,20,,,,,From NECB 2011 +DXHEAT-NECB2011-REF-PLFFPLR,DX Heating Coil,Cubic,EIRRatio,QRatio,,0.3696,2.3362,-2.9577,1.2596,,,,,,,0.7,1,,,,,From NECB 2011 +Minisplit-Heat-Cap-fT,DX Heating Coil,BiQuadratic,QRatio,Tiadb,Toadb,1.14715889,-0.010386676,0,0.008653846,0,0,,,,,-100,100,-100,100,,,From OpenStudio-HPXML +Minisplit-Heat-Cap-fFF,DX Heating Coil,Quadratic,QRatio,Tiadb,Toadb,1,0,0,,,,,,,,0,2,0,2,,,From OpenStudio-HPXML +Minisplit-Heat-EIR-fT,DX Heating Coil,BiQuadratic,EIRRatio,Tiadb,Toadb,0.99999417,0.004684594,5.90129E-05,-0.002862447,1.30411E-05,-0.000161729,,,,,-100,100,-100,100,,,From OpenStudio-HPXML +Minisplit-Heat-EIR-fFF,DX Heating Coil,Quadratic,EIRRatio,Tiadb,Toadb,1,0,0,,,,,,,,0,2,0,2,,,From OpenStudio-HPXML +Minisplit-Heat-PLF-fPLR,DX Heating Coil,BiQuadratic,EIRRatio,Tiadb,Toadb,0.89,0.11,,,,,,,,,0,1,0.6,1,,,From OpenStudio-HPXML +Minisplit-Cool-Cap-fT,DX Cooling Coil,BiQuadratic,QRatio,Tiadb,Toadb,0.75319835,0.003618194,0,0.006574385,-6.87181E-05,0,,,,,0,100,0,100,,,From OpenStudio-HPXML +Minisplit-Cool-Cap-fFF,DX Cooling Coil,Quadratic,QRatio,Tiadb,Toadb,1,0,0,,,,,,,,0,2,0,2,,,From OpenStudio-HPXML +Minisplit-Cool-EIR-fT,DX Cooling Coil,BiQuadratic,EIRRatio,Tiadb,Toadb,-0.063769248,-0.001336059,1.41306E-05,0.019433076,-4.91396E-05,-4.90934E-05,,,,,0,100,0,100,,,From OpenStudio-HPXML +Minisplit-Cool-EIR-fFF,DX Cooling Coil,Quadratic,EIRRatio,Tiadb,Toadb,1,0,0,,,,,,,,0,2,0,2,,,From OpenStudio-HPXML +Minisplit-Cool-PLF-fPLR,DX Cooling Coil,BiQuadratic,EIRRatio,Tiadb,Toadb,0.89,0.11,,,,,,,,,0,1,0.6,1,,,From OpenStudio-HPXML +EFG-Si_Spectral-fAirMass,PV-Module,Cubic,,AirMass,,0.93235892,0.05557786,-0.00723784,0.00016577,,,,,,,,,,,,,From .dat files included with MASControl2 +Elec-HW-Blr-EIR-fPLR,ElecBoilers,Linear,EIRRatio,PLR,,0.02,0.98,,,,,,,,,,,,,,,From .dat files included with MASControl2 +Elec-Stm-Blr-EIR-fPLR,ElecBoilers,Linear,EIRRatio,PLR,,0.03,0.97,,,,,,,,,,,,,,,From .dat files included with MASControl2 +Engine-Chlr-Cap-fCHWT&ECT,EngineChiller,BiQuadratic,QRatio,CHWT,ECT,1.02245976,0.033624396,0,-0.00837585,0,0,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Engine-Chlr-HeatRej-fECT,EngineChiller,Cubic,,ECT,,0.81658293,0.00622926,0,0,,,,,,,60,150,,,,,From .dat files included with MASControl2 +Engine-Chlr-HeatRej-fPLR,EngineChiller,Cubic,,PLR,,1.05269921,-0.05269912,0,0,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Engine-Chlr-HIR-fCHWT&ECT,EngineChiller,BiQuadratic,,CHWT,ECT,0.76855672,-0.016619742,0.001163452,0.007451082,0.000302,-0.000971,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Engine-Chlr-HIR-fPLR,EngineChiller,Quadratic,,PLR,,0.12571636,0.34714213,0.52714163,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Engine-Exh-fPLR,EngineGenerator,Quadratic,,PLR,,0.024516,0.3323871,0.6430968,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Engine-HIR-fPLR,EngineGenerator,Linear,,PLR,,0.107,0.893,,,,,,,,,,,,,,,From .dat files included with MASControl2 +Engine-Jac-fPLR,EngineGenerator,Quadratic,,PLR,,0.287936,1.0204516,-0.3083871,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +FluidCooler-FluidCap-fApp&WB,FluidCooler,BiQuadratic,QRatio,App,WB,-0.16463568,0.048677022,-0.001437296,0.072275256,0.000924,0.005085439,,,,,,,,,,,From .dat files included with MASControl2 +FluidCooler-FluidCap-fRng&WB,FluidCooler,BiQuadratic,QRatio,Rng,WB,0,0.18,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 +ForcedDraft-Blr-HIR-fPLR,FuelBoilers,Quadratic,,PLR,,0.01599992,0.94495332,0.03904687,,,,,,,,,,,,,,From .dat files included with MASControl2 +ForCurve w Dischrg Dampers FPLR,FanEIR-FPLR,Quadratic,,PLR,,0.190667,0.31,0.5,,,,,,,,,,,,0.22,1,From .dat files included with MASControl2 +ForCurve w Inlet Vanes FPLR,FanEIR-FPLR,Quadratic,,PLR,,0.339619,-0.848139,1.495671,,,,,,,,,,,,0.22,1,From .dat files included with MASControl2 +FURNACE_PACU_VAV_CoolCCarrier48TM014_12tons_EIRFFF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.19525,-0.306138,0.110973,,,,,,,,0.75,1.25,,,,,From PNNL OfficeMedium +FURNACE_PACU_VAV_CoolCCarrier48TM014_12tons_EIRFT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,-0.536161,0.105138,-0.00172659,0.0149848,0.000659948,-0.0017385,,,,,16.5556,22.1111,23.7778,47.66,,,From PNNL Prototype Buildings OfficeMedium +FURNACE-EFFPLR-NECB2011,Gas Heating Coil,Cubic,FIRRatio,QRatio,,0.7277,1.0667,-1.5174,0.7282,,,,,,,0,1,,,,,From NECB 2011 +Furnace-HIR-fPLR,Furnace,Quadratic,FIRRatio,PLR,,0.0186,1.09,-0.113,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Gas-Absor-Cap-fCHWT&ECT,Chiller/Heater,BiQuadratic,QRatio,CHWT,ECT,0.362073,0.0001386,0.001458,0.0733878,-0.00206064,0.00101,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Gas-Absor-HCap-fCoolPLR,Chiller/Heater,Quadratic,QRatio,CoolPLR,,0.863599,-1.30495346,0.44135284,,,,,,,,,,,,,,From .dat files included with MASControl2 +Gas-Absor-HIR-fCHWT&ECT,Chiller/Heater,BiQuadratic,,CHWT,ECT,0.96182051,-0.0507105,0.003155468,0.005732838,0.000349,-0.00118516,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Gas-Absor-HIR-fDesiccantT,Chiller/Heater,Cubic,,DesiccantT,,0.85427336,0.002997504,0.0000426,0,,,,,,,100,300,,,,,From .dat files included with MASControl2 +Gas-Absor-Qreg-fDesiccantT,Chiller/Heater,Cubic,,DesiccantT,,0.5984,-0.00234,0,0,,,,,,,100,300,,,,,From .dat files included with MASControl2 +GasTurbine-Cap-fPLR,GasTurbineGen,Linear,QRatio,PLR,,1.24,-0.0041,,,,,,,,,,,,,,,From .dat files included with MASControl2 +GasTurbine-Exh-fPLR,GasTurbineGen,Quadratic,,PLR,,0.295626,0.4930194,0.2113548,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +GasTurbine-HIR-fPLR,GasTurbineGen,Quadratic,,PLR,,0.442979,0.3974,0.1569621,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +GHP-Bypass-Factor-fAirflow,GasHeat-Pump,Quadratic,QRatio,Airflow,,-0.254,1.22,0.036,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +GHP-Bypass-Factor-fEWB&EDB,GasHeat-Pump,BiQuadratic,QRatio,EWB,EDB,0.85028352,0.014256792,0.000184,-0.014791716,-0.00000548,0.000487,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +GHP-Bypass-Factor-fPLR,GasHeat-Pump,Linear,QRatio,PLR,,1,0,,,,,,,,,,,,,,,From .dat files included with MASControl2 +GHP-Cool-Cap-fEWB&OAT,GasHeat-Pump,BiLinear,QRatio,EWB,OAT,1.1688,0.01926,-0.01539,,,,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +GHP-Cool-Cap-fRPM&OAT,GasHeat-Pump,BiQuadratic,QRatio,RPM,OAT,-372.736,-234.129654,-36.65800433,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 +GHP-Cool-CondFan-fPLR&OAT,GasHeat-Pump,BiQuadratic,,PLR,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 +GHP-Cool-CycleLoss-fPLR,GasHeat-Pump,Linear,QRatio,PLR,,0.82,0.18,,,,,,,,,,,,,,,From .dat files included with MASControl2 +GHP-Cool-HIR-fEWB&OAT,GasHeat-Pump,BiQuadratic,,EWB,OAT,1.1386752,-0.049248,0.000914,0.02128896,0.000306,-0.000953,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +GHP-Cool-HIR-fRPM&OAT,GasHeat-Pump,BiQuadratic,,RPM,OAT,-369.60598,-234.0532596,-36.93157152,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 +GHP-Cool-Waste-Heat-fEWB&OAT,GasHeat-Pump,BiLinear,QRatio,EWB,OAT,1,0,0,,,,,,,,,,,,,,From .dat files included with MASControl2 +GHP-Cool-Waste-Heat-fRPM&OAT,GasHeat-Pump,BiQuadratic,QRatio,RPM,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 +GHP-Defrost-Frac-fOWB&ODB,GasHeat-Pump,BiLinear,QRatio,OWB,ODB,0.0333,0,0,,,,,,,,-23.33333,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 +GHP-Heat-Cap-fEDB&OAT,GasHeat-Pump,BiQuadratic,QRatio,EDB,OAT,0.8291632,0,0,0.01817136,0.000281,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 +GHP-Heat-Cap-fRPM&OAT,GasHeat-Pump,BiQuadratic,QRatio,RPM,OAT,157.86,89.17133162,12.58409104,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 +GHP-Heat-CondFan-fPLR&OAT,GasHeat-Pump,BiQuadratic,,PLR,OAT,1,0,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 +GHP-Heat-CycleLoss-fPLR,GasHeat-Pump,Linear,QRatio,PLR,,0.82,0.18,,,,,,,,,,,,,,,From .dat files included with MASControl2 +GHP-Heat-HIR-fEDB&OAT,GasHeat-Pump,BiQuadratic,,EDB,OAT,1.14897728,0,0,-0.017395056,-0.000026,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 +GHP-Heat-HIR-fRPM&OAT,GasHeat-Pump,BiQuadratic,,RPM,OAT,194.037,109.788263,15.50214113,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 +GHP-Heat-Waste-Heat-fEDB&OAT,GasHeat-Pump,BiLinear,QRatio,EDB,OAT,1,0,0,,,,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 +GHP-Heat-Waste-Heat-fRPM&OAT,GasHeat-Pump,BiQuadratic,QRatio,RPM,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 +GHP-Sens-Cap-fEWB&OAT,GasHeat-Pump,BiQuadratic,QRatio,EWB,OAT,1.49637568,0.079056576,-0.004212,-0.030189312,0.000157,0.00062,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +Glass Door Defrost Curve,Refrigerated Case,Cubic,,,,0.3475,0.0296,0.0007,0.00003,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings +Glass Door Latent Curve,Refrigerated Case,Cubic,,,,0.3379,0.0309,0.0005,0.00004,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings +GoodCyclingAC-EIR-fPLR,CyclingAC,Cubic,EIRRatio,PLR,,0.00000273,1.05259,-0.0552087,0.00262236,,,,,,,,,,,,,From .dat files included with MASControl2 +GSHP/WLHP_BF_fAirflow-Old,GSHP/WLHPCurves,Cubic,QRatio,Airflow,,-0.828,14.3,-21.9,9.4,,,,,,,,,,,,,From .dat files included with MASControl2 +GSHP/WLHP_BF_fEwbEwt,GSHP/WLHPCurves,BiLinear,QRatio,EWB,EWT,-0.2016,0.0297,0.02646,,,,,,,,,,,,0.347365,1.67341,From .dat files included with MASControl2 +GSHP/WLHP_BF_fEwbEwt-Old,GSHP/WLHPCurves,BiQuadratic,QRatio,EWB,EWT,-5.522656,0.735768,-0.0185004,0.1418832,0.000943,-0.010206,,,,,,,,,,,From .dat files included with MASControl2 +GSHP/WLHP_Cool_Cap_fEwbEwt,GSHP/WLHPCurves,BiLinear,QRatio,EWB,EWT,0.88114368,0.015264,-0.007493418,,,,,,,,,,,,0.803411,1.18555,From .dat files included with MASControl2 +GSHP/WLHP_Cool_EIR_fEwbEwt,GSHP/WLHPCurves,BiLinear,EIRRatio,EWB,EWT,0.4111216,-0.00396,0.03011184,,,,,,,,,,,,0.300674,1.80627,From .dat files included with MASControl2 +GSHP/WLHP_H/C_EIR-fPLR,GSHP/WLHPCurves,Quadratic,EIRRatio,PLR,,0.0414,0.328,0.575337,,,,,,,,,,,,0,1,From .dat files included with MASControl2 +GSHP/WLHP_H/C_EIR-fPLR-Old,GSHP/WLHPCurves,Cubic,EIRRatio,PLR,,0.00988,1.08,-0.105,0.0151,,,,,,,,,,,,,From .dat files included with MASControl2 +GSHP/WLHP_Heat_Cap_fEdbEwt,GSHP/WLHPCurves,BiLinear,QRatio,EDB,EWT,1.07264,-0.003564,0.027,,,,,,,,,,,,0.966284,1.86368,From .dat files included with MASControl2 +GSHP/WLHP_Heat_EIR_fEdbEwt,GSHP/WLHPCurves,BiLinear,EIRRatio,EDB,EWT,0.59444,0.01908,-0.009774,,,,,,,,,,,,0.681922,1.10294,From .dat files included with MASControl2 +HeatSys1 Boiler Non-Condensing Boiler Curve,Boiler,Cubic,FIRRatio,QRatio,,0.626428326,0.645643582,-0.77720685,0.313806701,,,,,,,0.1,1,,,,,From Prototype Buildings +HeatWheel-EIR-fSpeed,ERVUnit,Linear,EIRRatio,Speed,,25.8,7.639437277,,,,,,,,,,,,,,,From .dat files included with MASControl2 +Herm-Cent-Cap-fCHWT&ECT,HermCentrifugal,BiQuadratic,QRatio,CHWT,ECT,0.257896,0.0389016,-0.000217,0.0468684,-0.000943,-0.000343,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Herm-Cent-EIR-fCHWT&ECT,HermCentrifugal,BiQuadratic,EIRRatio,CHWT,ECT,0.933884,-0.058212,0.00450036,0.00243,0.000486,-0.001215,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Herm-Cent-EIR-fPLR,HermCentrifugal,Quadratic,EIRRatio,PLR,,0.222903,0.313387,0.46371,,,,,,,,0,0.105,,,,,From .dat files included with MASControl2 +Herm-Rec-Cap-fCHWT&ECT,HermReciprocatg,BiQuadratic,QRatio,CHWT,ECT,0.507883,0.1452276,-0.00625644,-0.0011178,-0.00013,-0.000282,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Herm-Rec-EIR-fCHWT&ECT,HermReciprocatg,BiQuadratic,EIRRatio,CHWT,ECT,1.030757,-0.103536,0.00710208,0.0093186,0.000318,-0.00104,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Herm-Rec-EIR-fPLR,HermReciprocatg,Quadratic,EIRRatio,PLR,,0.088065,1.137742,-0.225806,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Hospital Kitchen_Flr_5_Case:1_WALKINFREEZERSingleShelfHorizontal_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.0236,0.0006,0,0,,,,,,,-35,20,,,,,From Prototype Buildings +Hospital Kitchen_Flr_5_Case:2_SELFCONTAINEDDISPLAYCASEMultiShelfVertical_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,6.02558E-05,1.23732E-06,,,,,,,-35,20,,,,,From Prototype Buildings +HotelLarge Kitchen_Flr_6_Case:1_WALKINFREEZERSingleShelfHorizontal_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.0236,0.0006,0,0,,,,,,,-35,20,,,,,From Prototype Buildings +HotelLarge Kitchen_Flr_6_Case:2_SELFCONTAINEDDISPLAYCASEMultiShelfVertical_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,6.02558E-05,1.23732E-06,,,,,,,-35,20,,,,,From Prototype Buildings +HP-Bypass-Factor-fAirflow,Water-LoopHP,Cubic,QRatio,Airflow,,-0.828,14.3,-21.9,9.4,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +HP-Bypass-Factor-fEWB&EWT,Water-LoopHP,BiQuadratic,QRatio,EWB,EWT,-5.522656,0.735768,-0.0185004,0.1418832,0.000943,-0.010206,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +HP-Cool-Cap-fEWB&EWT,Water-LoopHP,BiQuadratic,QRatio,EWB,EWT,0.38053696,0.041974272,-0.0000309,-0.006642864,0.0000228,-0.0000881,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +HP-Cool-EIR-fEWB&EWT,Water-LoopHP,BiQuadratic,EIRRatio,EWB,EWT,1.3257696,-0.0504504,0.000988,0.02036448,0.0000791,-0.000531,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +HP-Cool-EIR-fPLR,Water-LoopHP,Linear,EIRRatio,PLR,,0.125,0.875,,,,,,,,,,,,,,,From .dat files included with MASControl2 +HP-Heat-Cap-fEDB&EWT,Water-LoopHP,BiLinear,QRatio,EDB,EWT,0.72324,-0.012204,0.02538,,,,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +HP-Heat-EIR-fEDB&EWT,Water-LoopHP,BiLinear,EIRRatio,EDB,EWT,1.2124,0.01089,-0.02088,,,,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +HP-Heat-EIR-fPLR,Water-LoopHP,Cubic,EIRRatio,PLR,,0.0857,0.939,-0.183,0.15897022,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +HP-Sens-Cap-fAirflow,Water-LoopHP,Cubic,QRatio,Airflow,,-0.13,2.16,-1.6,0.573,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +HP-Sens-Cap-fEWB&EWT,Water-LoopHP,BiQuadratic,QRatio,EWB,EWT,1.68318464,0.012410496,-0.00215784,-0.009251064,0.0000632,0.000174,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +HPACCoolCapFFF,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,, +HPACCoolCapFT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.766956,0.0107756,-4.14703E-05,0.00134961,-0.000261144,0.000457488,,,,,12.77778,23.88889,21.11111,46.11111,,, +HPACCOOLEIRFFF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.156,-0.1816,0.0256,,,,,,,,0.5,1.5,,,,, +HPACCOOLEIRFT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.297145,0.0430933,-0.000748766,0.00597727,0.000482112,-0.000956448,,,,,12.77778,23.88889,21.11111,46.11111,,, +HPACCOOLPLFFPLR,DX Cooling Coil,Quadratic,EIRRatio,QRatio,,0.85,0.15,0,,,,,,,,0,1,,,,, +HPACHeatCapFFF,DX Heating Coil,Cubic,QRatio,FlowRatio,,0.84,0.16,0,0,,,,,,,0.5,1.5,,,,,From Prototype Buildings +HPACHeatCapFT,DX Heating Coil,Cubic,QRatio,Toadb,,0.758746,0.027626,0.000148716,3.4992E-06,,,,,,,-20,20,,,,,From Prototype Buildings +HPACHeatEIRFFF,DX Heating Coil,Quadratic,EIRRatio,FlowRatio,,1.3824,-0.4336,0.0512,,,,,,,,0,1,,,,,From Prototype Buildings +HPACHeatEIRFT,DX Heating Coil,Cubic,EIRRatio,Toadb,,1.19248,-0.0300438,0.00103745,-0.000023328,,,,,,,-20,20,,,,,From Prototype Buildings +Htrec-Chlr-Cap-fCHWT&ECT,ElecHeatRecover,BiQuadratic,QRatio,CHWT,ECT,0.257896,0.0389016,-0.000217,0.0468684,-0.000943,-0.000343,,,,,4.44444,18.33333,12.77778,51.66667,,,From .dat files included with MASControl2 +Htrec-Chlr-EIR-fCHWT&ECT,ElecHeatRecover,BiQuadratic,EIRRatio,CHWT,ECT,0.933884,-0.058212,0.00450036,0.00243,0.000486,-0.001215,,,,,4.44444,18.33333,12.77778,51.66667,,,From .dat files included with MASControl2 +Htrec-Chlr-EIR-fPLR,ElecHeatRecover,Quadratic,EIRRatio,PLR,,0.349032,0.263871,0.387097,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Htrej-Fan-Pwr-fDamper,FluidCooler,Cubic,,Damper,,0.37607971,-0.21440694,1.00540793,-0.16712119,,,,,,,,,,,0.36,1,From .dat files included with MASControl2 +HW-Coil-Cap-fAirflow,HWCoils,Quadratic,QRatio,Airflow,,0.289,1.03,-0.317,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +HW-Coil-Cap-fdT,HWCoils,Quadratic,QRatio,dT,,-0.00467,1.8,0.010960272,,,,,,,,0,150,,,0.01,,From .dat files included with MASControl2 +HW-Coil-Cap-fFluidFlow,HWCoils,Quadratic,QRatio,FluidFlow,,0.18,2945.2432,-2540000,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Indirect-Effectiveness-fFlow,EvapCooler,Quadratic,,Flow,,1.1,-350,306000,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Inverter_EIR-fPLR,PV-Inverter,Quadratic,EIRRatio,PLR,,0.01677774,1.03766656,-0.05444431,,,,,,,,,,,,,,From .dat files included with MASControl2 +Large-CHW-Bypass-fAirflow,CHWCoils,Quadratic,QRatio,Airflow,,0.397,0.15,0.45374713,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Large-CHW-Coil-Bypass-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,0.435936,0.23652,-0.0047628,-0.1330272,0.00119556,0.000859,,,,,15.55556,29.44444,12.77778,29.44444,,,From .dat files included with MASControl2 +Large-CHW-Coil-Cap-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,0.09793216,-0.13886496,0.0124416,0.088907328,0.001938946,-0.009305604,,,,,15.55556,29.44444,12.77778,29.44444,,,From .dat files included with MASControl2 +Large-CHW-Sens-Cap-fAirflow,CHWCoils,Quadratic,QRatio,Airflow,,0.202,0.855,-0.057,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Large-CHW-Sens-Cap-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,0.12076864,-0.124558848,0.0063828,0.11146032,0.001847902,-0.006508285,,,,,15.55556,13.33333,12.77778,29.44444,,,From .dat files included with MASControl2 +Lp2Lp_Cap_fCHW&HWR,Loop2Loop,BiQuadratic,QRatio,CHWT,HWR,0.95122179,0.035393436,0.00027,-0.002654118,-0.0000869,-0.000274,,,,,,,,,,,From .dat files included with MASControl2 +Lp2Lp_EIR_fCHW&HWR,Loop2Loop,BiQuadratic,EIRRatio,CHWT,HWR,0.59918703,-0.00950724,0.000335,0.00863883,0.000312,-0.000386,,,,,,,,,,,From .dat files included with MASControl2 +Lp2Lp-EIR-fPLR-1Comp/Ckt,Loop2Loop,Quadratic,EIRRatio,PLR,,0.03481113,0.95945376,0.00573495,,,,,,,,,,,,,,From .dat files included with MASControl2 +Lp2Lp-EIR-fPLR-2Comp/Ckt,Loop2Loop,Quadratic,EIRRatio,PLR,,0.02297712,0.90150452,0.07551826,,,,,,,,,,,,,,From .dat files included with MASControl2 +LT_compressor_capacity,Refrigeration,BiCubic,Capacity,Suction T,Discharge T,170751.834,6102.9037,78.2619862,-2959.4326,19.7876589,-90.958101,0.43596477,-0.0411577,-0.608846,0.459133262,-40,17.8,4.4,54.4,,,From AEDG +LT_compressor_power,Refrigeration,BiCubic,Power,Suction T,Discharge T,29669.2711,1027.63205,18.1066262,-442.19971,11.1335288,-20.380452,0.13998065,-0.0588669,-0.2184515,0.203858467,-40,-17.8,4.4,54.4,,,From AEDG +mc-Si_Spectral-fAirMass,PV-Module,Cubic,,AirMass,,0.96113414,0.02820018,-0.00134585,-0.00012036,,,,,,,,,,,,,From .dat files included with MASControl2 +Measured_CoolCStandard10Ton_EIRFFF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.192,-0.1917,0,,,,,,,,0.776,1.197,,,,,From PNNL Prototype FullServiceRestaurant +MNECB-CAP-FAPP&WB,CAP-FAPP&WB,BiQuadratic,QRatio,App,WB,-0.05425558,-0.063981648,0.026052289,0.260016714,0.000809093,0.015903767,,,,,,,,,,,From .dat files included with MASControl2 +MNECB-CAP-FRNG&WB,CAP-FRNG&WB,BiQuadratic,QRatio,Rng,WB,188.8588489,0.300231774,-0.045692003,35.40844622,0.601350934,0.78576062,,,,,,,,,,,From .dat files included with MASControl2 +MNECB-Centrif-CAP-FT,Centrif-CAP-FT,BiQuadratic,QRatio,T,T,0.70790824,-0.002006568,-0.00259605,0.030058776,-0.001056434,0.002045704,,,,,,,,,,,From .dat files included with MASControl2 +MNECB-Centrif-EIR-FPLR,Centrif-EIR-FPLR,Quadratic,EIRRatio,PLR,,0.17149273,0.58820208,0.23737257,,,,,,,,,,,,,,From .dat files included with MASControl2 +MNECB-Centrif-EIR-FT,Centrif-EIR-FT,BiQuadratic,EIRRatio,T,T,0.5605438,-0.01377927,0.0000657,0.013219362,0.000268596,-0.000501131,,,,,,,,,,,From .dat files included with MASControl2 +MNECB-DW-HIR-fPLR,DHW-HIR,Quadratic,,PLR,,0.021826,0.97763,0.000543,,,,,,,,,,,,,,From .dat files included with MASControl2 +MNECB-HW-HIR-fPLR,HW-HIR,Quadratic,,PLR,,0.082597,0.996764,-0.079361,,,,,,,,,,,,,,From .dat files included with MASControl2 +MNECB-Recip-CAP-FT,Recip-CAP-FT,BiQuadratic,QRatio,T,T,1.0303123,0.033469794,0.00023639,-0.007295868,-0.0000232,-0.000148943,,,,,,,,,,,From .dat files included with MASControl2 +MNECB-Recip-EIR-FPLR,Recip-EIR-FPLR,Quadratic,EIRRatio,PLR,,0.08144133,0.41927141,0.49939604,,,,,,,,,,,,,,From .dat files included with MASControl2 +MNECB-Recip-EIR-FT,Recip-EIR-FT,BiQuadratic,EIRRatio,T,T,0.49969897,-0.013084056,0.000266425,0.016592526,0.000185393,-0.000375646,,,,,,,,,,,From .dat files included with MASControl2 +Multi Shelf Vertical Latent Energy Multiplier,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,-6.02558E-05,1.23732E-06,,,,,,,-35,20,,,,,From Reference Buildings +Multi Zone VAV with Airfoil or Backward Incline riding the curve,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.1631,1.5901,-0.8817,0.1281,,,,,,,0,1,,,0.7,,From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method +Multi Zone VAV with Airfoil or Backward Incline with inlet vanes,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.9977,-0.659,0.9547,-0.2936,,,,,,,0,1,,,0.5,,From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method +Multi Zone VAV with Forward Curved fans riding the curve,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.1224,0.612,0.5983,-0.3334,,,,,,,0,1,,,0.3,,From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method +Multi Zone VAV with Forward Curved with inlet vanes,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.3038,-0.7608,2.2729,-0.8169,,,,,,,0,1,,,0.3,,From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method +Multi zone VAV with static pressure reset,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.040759894,0.08804497,-0.07292612,0.943739823,,,,,,,0,1,,,0.1,,"OpenStudio default, baseline for System Types 5-8 from ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method" +Multi Zone VAV with vane-axial with variable pitch blades,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.1639,-0.4016,1.9909,-0.7541,,,,,,,0,1,,,0.2,,From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method +Multi Zone VAV with VSD and fixed SP setpoint,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.0013,0.147,0.9506,-0.0998,,,,,,,0,1,,,0.2,,Appendix G baseline from ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method +New_Low_Temp_Comp_Cap_Curve,,BiCubic,,,,58336.861,1561.7435,6.6068129,-283.65007,-0.12023494,-12.495749,-0.11627856,0.002277001,-0.11814833,0.032839613,-40,-17.8,4.4,54.4,,, +New_Low_Temp_Comp_Pwr_Curve,,BiCubic,,,,6274.9904,61.390661,1.6208537,129.11279,0.87411617,1.9581173,0.030293311,0.005754678,0.004653957,-0.000749905,-40,-17.8,4.4,54.4,,, +New_Med_Temp_Comp_Cap_Curve,,BiCubic,,,,61412.175,1570.8519,13.533449,-500.19524,8.1639124,-3.6895385,0.054485574,-0.088096805,0.006381584,-0.037503058,-23.3,7.2,10,60,,, +New_Med_Temp_Comp_Pwr_Curve,,BiCubic,,,,4994.0336,170.24972,2.8463891,356.79403,-6.3074704,-1.409856,0.012160476,0.076231729,-0.057527471,0.009054446,-23.3,7.2,10,60,,, +No SP Reset VSD Fan,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.070428852,0.385330201,-0.460864118,1.00920344,,,,,,,0,1,,,0.1,,"From California Energy Commision, ""Advanced Variable Air Volume System Design Guide,"" October 2004" +Old_Low_Temp_Comp_Cap_Curve,,BiCubic,,,,170751.834,6102.9037,78.2619862,-2959.43265,19.7876589,-90.9581015,0.435964768,-0.041157653,-0.60884596,0.459133262,-40,-17.8,4.4,54.4,,, +Old_Low_Temp_Comp_Pwr_Curve,,BiCubic,,,,29669.2711,1027.63205,18.1066262,-442.199714,11.1335288,-20.3804519,0.139980653,-0.058866918,-0.218451538,0.203858467,-40,-17.8,4.4,54.4,,, +Old_Med_Temp_Comp_Cap_Curve,,BiCubic,,,,151166.436,5266.34789,60.6727151,-1851.55938,5.73132755,-46.9277173,0.136401203,-0.035697884,-0.403053994,-0.039290478,-23.3,7.2,10,60,,, +Old_Med_Temp_Comp_Pwr_Curve,,BiCubic,,,,7438.92229,-269.597565,-9.85610446,553.57326,-3.38588961,14.8657878,-0.100796292,0.009822793,0.097362356,-0.039675217,-23.3,7.2,10,60,,, +Open Latent Curve,Refrigerated Case,Cubic,,,,-0.0187,0.0458,0.0011,0.00005,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings +Open-Cent-Cap-fCHWT&ECT,OpenCentrifugal,BiQuadratic,QRatio,CHWT,ECT,0.257896,0.0389016,-0.000217,0.0468684,-0.000943,-0.000343,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Open-Cent-EIR-fCHWT&ECT,OpenCentrifugal,BiQuadratic,EIRRatio,CHWT,ECT,0.933884,-0.058212,0.00450036,0.00243,0.000486,-0.001215,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Open-Cent-EIR-fPLR,OpenCentrifugal,Quadratic,EIRRatio,PLR,,0.222903,0.313387,0.46371,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Open-Rec-Cap-fCHWT&ECT,OpenReciprocatg,BiQuadratic,QRatio,CHWT,ECT,0.507883,0.1452276,-0.00625644,-0.0011178,-0.00013,-0.000282,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Open-Rec-EIR-fCHWT&ECT,OpenReciprocatg,BiQuadratic,EIRRatio,CHWT,ECT,1.030757,-0.103536,0.00710208,0.0093186,0.000318,-0.00104,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 +Open-Rec-EIR-fPLR,OpenReciprocatg,Quadratic,EIRRatio,PLR,,0.088065,1.137742,-0.225806,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +OpenTwr-FluidCap-fApp&WB,OpenTower,BiQuadratic,QRatio,App,WB,0.11735985,0.010588518,0.000701,0.052439526,0.000724,0.003437899,,,,,,,,,,,From .dat files included with MASControl2 +OpenTwr-FluidCap-fRng&WB,OpenTower,BiQuadratic,QRatio,Rng,WB,0.11661702,0.202450932,-0.004401443,-0.01592307,0.000101,-0.001101632,,,,,,,,,,,From .dat files included with MASControl2 +PoorCyclingAC-EIR-fPLR,CyclingAC,Cubic,EIRRatio,PLR,,0.000362523,1.32573,-0.407603,0.0818194,,,,,,,,,,,,,From .dat files included with MASControl2 +PSZ-AC DX Coil EIR-FT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.342414409,0.034885008,-0.0006237,0.004977216,0.000437951,-0.000728028,,,,,12.77778,23.88889,23.88889,46.11111,,,"From PNNL Prototype Buildings HotelSmall, Warehouse" +PSZ-AC DX Unitary Package EIRFT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.297145,0.0430933,-0.000748766,0.00597727,0.000482112,-0.000956448,,,,,12.77778,23.88889,21.11111,46.11111,,,"From PNNL Prototype Buildings RetailStandAlone, RetailStripMall,SchoolPrimary" +PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.42415,0.04426,-0.00042,0.00333,-0.00008,-0.00021,,,,,17,22,29,46,,,"From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" +PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR,DX Cooling Coil,Quadratic,EIRRatio,QRatio,,0.771,0.229,0,,,,,,,,0,1,,,,,"From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" +PSZ-AC_CoolCStandard10Ton_EIRFT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,1.23649,-0.02431,0.00057,-0.01434,0.00063,-0.00038,,,,,17,22,29,46,,,"From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" +PSZ-AC_Unitary_PackagecoolCapFT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.766956,0.0107756,-4.14703E-05,0.00134961,-0.000261144,0.000457488,,,,,12.77778,23.88889,21.11111,46.11111,,,"From PNNL Prototype Buildings RetailStandalone, RetailStripMall, SchoolPrimary" +PSZ-AC_Unitary_PackagecoolEIRFFF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.156,-0.1816,0.0256,,,,,,,,0.5,1.5,,,,, +PSZ-AC_Unitary_PackagecoolFFF,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,, +PSZ-AC_Unitary_PackagecoolPLR,DX Cooling Coil,Quadratic,EIRRatio,QRatio,,0.75,0.25,0,,,,,,,,0,1,,,,,"From PNNL Prototype Buildings RetailStandAlone, RetailStripMall, SchoolPrimary" +PSZ-AC:1_Unitary_PackagecoolEIRFFF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.156,-0.1816,0.0256,,,,,,,,0.5,1.5,,,,,"From PNNL Prototype Buildings RetailStandAlone, RetailStripMall, SchoolPrimary" +PSZ-Fine Storage DX Coil Cap-FT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.942587793,0.009543347,0.00068377,-0.011042676,0.000005249,-0.00000972,,,,,12.77778,23.88889,23.88889,46.11111,,,"From PNNL Prototype Buildings HotelSmall, Warehouse" +PSZ-Fine Storage Heating Coil PLF-FPLR,DX Heating Coil,Cubic,EIRRatio,QRatio,,0.8,0.2,0,0,,,,,,,0,1,,,,,From Prototype Buildings +PSZ-Office Heating Coil PLF-FPLR,DX Heating Coil,Cubic,EIRRatio,QRatio,,0.8,0.2,0,0,,,,,,,0,1,,,,,From Prototype Buildings +PSZ135to240_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 +PSZ135to240_BF_fT,BF_fT,BiQuadratic,,T,T,43.269632,-4.898304,0.148392,0.0947376,0.00213192,-0.0134136,,,,,,,,,0,4.04,From .dat files included with MASControl2 +PSZ135to240_CEIR_fPLR,CEIR_fPLR,Cubic,EIRRatio,PLR,,0.0184,1.15,-0.208,0.0423,,,,,,,,,,,,,From .dat files included with MASControl2 +PSZ135to240_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.62774528,-0.060192,0.00260172,-0.005653656,0.0000266,-0.00040824,,,,,,,,,,,From .dat files included with MASControl2 +PSZ135to240_CLoss_fPLR,CLoss_fPLR,Cubic,,PLR,,0.852,0.203,-0.0423,0.00938,,,,,,,,,,,0.8024,1.0728,From .dat files included with MASControl2 +PSZ135to240_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,0.4018688,0.1920384,-0.0077436,-0.01956816,-0.0000415,0.00077436,,,,,,,,,,,From .dat files included with MASControl2 +PSZ135to240_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,-0.0449056,0.07059456,-0.00216432,0.00440856,0.00041148,-0.000245916,,,,,,,,,,,From .dat files included with MASControl2 +PSZ135to240_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 +PSZ135to240_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 +PSZ240to760_BF_fFlow,BF_fFlow,Linear,QRatio,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 +PSZ240to760_BF_fT,BF_fT,BiQuadratic,,T,T,15.8724544,-1.6604928,0.041148,0.03013992,0.000278964,0.00047628,,,,,,,,,0,3.252,From .dat files included with MASControl2 +PSZ240to760_CEIR_fPLR,CEIR_fPLR,Cubic,EIRRatio,PLR,,2.63,-9.5,14.3,-6.4,,,,,,,,,,,,,From .dat files included with MASControl2 +PSZ240to760_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.27910208,-0.0291096,0.00167184,-0.002266416,-0.000031,-0.00033372,,,,,,,,,,,From .dat files included with MASControl2 +PSZ240to760_CLoss_fPLR,CLoss_fPLR,Cubic,,PLR,,0.964,0.289,0.183,-0.131,,,,,,,,,,,0.96,1.3,From .dat files included with MASControl2 +PSZ240to760_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.64083712,-0.06152112,-0.0004698,-0.010834704,-0.0000289,0.000222912,,,,,,,,,,,From .dat files included with MASControl2 +PSZ240to760_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.336608,0.0487944,-0.00116316,-0.005994,0.00067716,-0.00069012,,,,,,,,,,,From .dat files included with MASControl2 +PSZ240to760_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 +PSZ240to760_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 +PSZ65to135_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 +PSZ65to135_BF_fT,BF_fT,BiQuadratic,,T,T,14.931264,-1.5724512,0.04698,0.0015984,0.00096552,-0.00319788,,,,,,,,,0,3.509,From .dat files included with MASControl2 +PSZ65to135_CEIR_fPLR,CEIR_fPLR,Cubic,EIRRatio,PLR,,0.0184,1.15,-0.208,0.0423,,,,,,,,,,,,,From .dat files included with MASControl2 +PSZ65to135_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.2518496,-0.02766672,0.00115344,0.0035388,-0.000134136,-0.000167508,,,,,,,,,,,From .dat files included with MASControl2 +PSZ65to135_CLoss_fPLR,CLoss_fPLR,Cubic,,PLR,,0.882,0.211,-0.0439,0.0098,,,,,,,,,,,0.8323,1.1087,From .dat files included with MASControl2 +PSZ65to135_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.7733472,0.0383688,-0.0038556,-0.01090224,-0.000138348,0.00070632,,,,,,,,,,,From .dat files included with MASControl2 +PSZ65to135_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.5431072,0.03102048,-0.00090072,-0.01496592,0.0006966,-0.000199908,,,,,,,,,,,From .dat files included with MASControl2 +PSZ65to135_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 +PSZ65to135_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 +PTAC_EIR_fPLR,PkgdTerminalACS,Cubic,EIRRatio,PLR,,0.125,0.875,0,0,,,,,,,,,,,,,From .dat files included with MASControl2 +PTAC-Bypass-Factor-fAirflow,PkgdTerminalAC,Quadratic,QRatio,Airflow,,-2.28,5.21,-1.93,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +PTAC-Bypass-Factor-fEWB&EDB,PkgdTerminalAC,BiQuadratic,QRatio,EWB,EDB,-0.219664,0.0994608,0.00102,-0.020394,0.00036,-0.00120528,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +PTAC-Cool-Cap-fEWB&OAT,PkgdTerminalAC,BiQuadratic,QRatio,EWB,OAT,0.93865088,0.0095364,0.000684,-0.011038176,0.00000525,-0.00000972,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +PTAC-EIR-fEWB&OAT,PkgdTerminalAC,BiQuadratic,EIRRatio,EWB,OAT,0.34208928,0.03484368,-0.000625,0.004968864,0.000438,-0.000728,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +PTAC-EIR-fPLR,PkgdTerminalAC,Linear,EIRRatio,PLR,,0.125,0.875,,,,,,,,,,,,,,,From .dat files included with MASControl2 +PTAC-Sens-Cap-fAirflow,PkgdTerminalAC,Linear,QRatio,Airflow,,0.6,0.4,,,,,,,,,,,,,,,From .dat files included with MASControl2 +PTAC-Sens-Cap-fEWB&OAT,PkgdTerminalAC,BiQuadratic,QRatio,EWB,OAT,3.2722656,-0.14984352,0.00140292,0.0047124,-0.000162,0.000207,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +PTACHPACEIRFT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.342414409,0.034885008,-0.0006237,0.004977216,0.000437951,-0.000728028,,,,,12.77778,23.88889,18.3,46.11111,,,From DOE Reference Buildings SmallHotel +Pump-Head-fFlow,Pumps,Quadratic,QRatio,Flow,,1.3534831,33.8,-1660000,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Pump-Power-fFlow,Pumps,Quadratic,,Flow,,0.3697739,1780.65378,-943000,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +PVV240to760_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 +PVV240to760_BF_fT,BF_fT,BiQuadratic,,T,T,8.747712,-1.2544704,0.034992,0.219888,-0.00221292,-0.00284796,,,,,,,,,0,3.2,From .dat files included with MASControl2 +PVV240to760_CEIR_fPLR,CEIR_fPLR,Cubic,EIRRatio,PLR,,0.124,0.376,1.29,-0.794,,,,,,,,,,,,,From .dat files included with MASControl2 +PVV240to760_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,0.9521152,-0.01097712,0.0012312,-0.00072792,-0.0000454,-0.000173988,,,,,,,,,,,From .dat files included with MASControl2 +PVV240to760_CLoss_fPLR,CLoss_fPLR,Cubic,,PLR,,0,1,0,0,,,,,,,,,,,0.1,1,From .dat files included with MASControl2 +PVV240to760_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.91654848,0.0047736,-0.00233604,-0.013756896,-0.0000323,0.00057672,,,,,,,,,,,From .dat files included with MASControl2 +PVV240to760_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.380192,0.0241488,-0.00047952,0.0111168,0.00052488,-0.00102384,,,,,,,,,,,From .dat files included with MASControl2 +PVV240to760_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 +PVV240to760_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 +PVVT-Bypass-Factor-fAirflow,PkgdVVVT,Quadratic,QRatio,Airflow,,-0.254,1.22,0.036,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +PVVT-Bypass-Factor-fEWB&EDB,PkgdVVVT,BiQuadratic,QRatio,EWB,EDB,0.85028352,0.014256792,0.000184,-0.014791716,-0.00000548,0.000487,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +PVVT-Cool-Cap-fEWB&OAT,PkgdVVVT,BiQuadratic,QRatio,EWB,OAT,0.86783424,0.014239008,0.000554,-0.007558056,0.000033,-0.000192,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +PVVT-Cool-EIR-fEWB&OAT,PkgdVVVT,BiQuadratic,EIRRatio,EWB,OAT,0.1210048,0.0285336,-0.000411,0.02134944,0.000161,-0.00068,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +PVVT-Cool-EIR-fPLR,PkgdVVVT,Cubic,EIRRatio,PLR,,0.201,-0.0312,1.9504979,-1.1205104,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +PVVT-Heat-Cap-fEDB&OAT,PkgdVVVT,BiQuadratic,QRatio,EDB,OAT,0.74200928,0,0,0.030668544,0.0000323,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 +PVVT-Heat-EIR-fEDB&OAT,PkgdVVVT,BiQuadratic,EIRRatio,EDB,OAT,1.255664,0,0,-0.0399528,0.00108864,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 +PVVT-Heat-EIR-fPLR,PkgdVVVT,Cubic,EIRRatio,PLR,,0.0857,0.939,-0.183,0.159,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +PVVT-Sens-Cap-fEWB&OAT,PkgdVVVT,BiQuadratic,QRatio,EWB,OAT,2.93229888,-0.09445968,0.0002,-0.007173756,0.0000103,0.000109,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +Rcmp-kW-f-Tc-T1-Hi-Eff,Refrigeration,Quadratic,,Tc,,0.635620298,0.003533521,0.000161,,,,,,,,,,,,0.7533,1.2802,From .dat files included with MASControl2 +Rcmp-kW-f-Tc-T1-Low-Eff,Refrigeration,Quadratic,,Tc,,1.113461,-0.0308988,0.000739,,,,,,,,,,,,0.950084,1.606833,From .dat files included with MASControl2 +Rcmp-kW-f-Tc-T2-Hi-Eff,Refrigeration,Quadratic,,Tc,,0.580834119,0.00494838,0.000161,,,,,,,,,,,,0.7262,1.3046,From .dat files included with MASControl2 +Rcmp-kW-f-Tc-T2-Low-Eff,Refrigeration,Quadratic,,Tc,,0.970164,-0.02268,0.000625,,,,,,,,,,,,0.943908,1.565353,From .dat files included with MASControl2 +Rcmp-kW-f-Tc-T3-Hi-Eff,Refrigeration,Quadratic,,Tc,,0.358796196,0.007319986,0.000257,,,,,,,,,,,,0.5728,1.4917,From .dat files included with MASControl2 +Rcmp-kW-f-Tc-T3-Low-Eff,Refrigeration,Quadratic,,Tc,,0.656539,-0.0039924,0.00035,,,,,,,,,,,,0.941987,1.418136,From .dat files included with MASControl2 +Rcmp-kW2-f-Tc-T1-Hi-Eff,Refrigeration,Quadratic,,Tc,,0.904478102,-0.008972199,0.000303,,,,,,,,,,,,0.8518,1.2802,From .dat files included with MASControl2 +Rcmp-kW2-f-Tc-T1-Low-Eff,Refrigeration,Quadratic,,Tc,,1.113461,-0.0308988,0.000739,,,,,,,,,,,,0.950084,1.606833,From .dat files included with MASControl2 +Rcmp-kW2-f-Tc-T2-Hi-Eff,Refrigeration,Quadratic,,Tc,,0.887325182,-0.009516488,0.000328,,,,,,,,,,,,0.8326,1.3046,From .dat files included with MASControl2 +Rcmp-kW2-f-Tc-T2-Low-Eff,Refrigeration,Quadratic,,Tc,,0.970164,-0.02268,0.000625,,,,,,,,,,,,0.943908,1.565353,From .dat files included with MASControl2 +Rcmp-kW2-f-Tc-T3-Hi-Eff,Refrigeration,Quadratic,,Tc,,0.829593266,-0.014865914,0.000512,,,,,,,,,,,,0.7434,1.4917,From .dat files included with MASControl2 +Rcmp-kW2-f-Tc-T3-Low-Eff,Refrigeration,Quadratic,,Tc,,0.656539,-0.0039924,0.00035,,,,,,,,,,,,0.941987,1.418136,From .dat files included with MASControl2 +Rcond-Fan-Pwr-fPLR-ACpress,Refrigeration,Linear,,PLR,,0,1,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 +Rcond-Fan-Pwr-fPLR-Damper,Refrigeration,Linear,,PLR,,0.3,0.7,,,,,,,,,,,,,0.3,1,From .dat files included with MASControl2 +RecipAir-Cap-fCHWT&DBT,HermReciprocatg,BiQuadratic,QRatio,CHWT,DBT,1.10674018,0.040197888,0.000286,-0.009552852,0.00000522,-0.000255,,,,,,,,,,,From .dat files included with MASControl2 +RecipAir-EIR-fCHWT&DBT,HermReciprocatg,BiQuadratic,EIRRatio,CHWT,DBT,0.53866251,-0.008142246,0.000125,0.011090538,0.000164,-0.000342,,,,,,,,,,,From .dat files included with MASControl2 +RecipAir-EIR-fPLR-1Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.03892594,1.07531738,-0.10724027,-0.001050714,0.00000943,0.000536346,,,,,,,,,,,From .dat files included with MASControl2 +RecipAir-EIR-fPLR-2Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.04812248,0.69573414,0.2349389,0.000819378,-0.00000386,0.0000379,,,,,,,,,,,From .dat files included with MASControl2 +RecipAir-EIR-fPLR-3Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.03296722,0.57721251,0.33923307,0.002786436,-0.0000311,-0.000119,,,,,,,,,,,From .dat files included with MASControl2 +RecipAir-EIR-fPLR-4Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.00434876,0.61917436,0.32643354,0.003223368,-0.0000333,-0.000514206,,,,,,,,,,,From .dat files included with MASControl2 +RecipH2O-Cap-fCHWT&ECT,HermReciprocatg,BiQuadratic,QRatio,CHWT,ECT,1.0689798,0.036781398,0.000334,-0.010426122,0.0000217,-0.000208,,,,,,,,,,,From .dat files included with MASControl2 +RecipH2O-EIR-fCHWT&ECT,HermReciprocatg,BiQuadratic,EIRRatio,CHWT,ECT,0.51329254,-0.015039378,0.000362,0.015398694,0.000228,-0.000409,,,,,,,,,,,From .dat files included with MASControl2 +RecipH2O-EIR-fPLR&dT-1Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,-0.0142974,0.95360994,0.01805304,0.002822994,-0.0000199,-0.000497988,,,,,,,,,,,From .dat files included with MASControl2 +RecipH2O-EIR-fPLR&dT-2Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.02391765,0.88946915,0.07793053,-0.000474426,0.0000233,0.000324,,,,,,,,,,,From .dat files included with MASControl2 +RecipRemote-Cap-fCHWT&SCT,HermReciprocatg,BiQuadratic,QRatio,CHWT,SCT,1.27977199,0.051393222,0.000332,-0.009522792,-0.0000197,-0.000269,,,,,,,,,,,From .dat files included with MASControl2 +RecipRemote-EIR-fCHWT&SCT,HermReciprocatg,BiQuadratic,EIRRatio,CHWT,SCT,0.25314951,-0.015358788,0.000506,0.009717714,0.000171,-0.000382,,,,,,,,,,,From .dat files included with MASControl2 +RecipRemote-EIR-fPLR-1Comp/Ckt,HermReciprocatg,Quadratic,EIRRatio,PLR,,0.03521065,0.93266129,0.03212802,,,,,,,,,,,,,,From .dat files included with MASControl2 +RecipRemote-EIR-fPLR-2Comp/Ckt,HermReciprocatg,Quadratic,EIRRatio,PLR,,0.02511026,0.8934145,0.08147529,,,,,,,,,,,,,,From .dat files included with MASControl2 +Refg-Condenser-Cap-fCondT&WBT,Refrigeration,BiQuadratic,QRatio,CondT,WBT,0.15373327,0.00942813,0.000693,-0.020963196,-0.000702,0.000302,,,,,,,,,0.2,2.222,From .dat files included with MASControl2 +Refg-kW-fECT-T1,Refrigeration,Quadratic,,ECT,,0.753416,-0.0212148,0.000739,,,,,,,,,,,,0.850358,1.747334,From .dat files included with MASControl2 +Refg-kW-fECT-T2,Refrigeration,Quadratic,,ECT,,1.00323,-0.0290574,0.000765,,,,,,,,,,,,0.859029,1.592964,From .dat files included with MASControl2 +Refg-kW-fECT-T3,Refrigeration,Quadratic,,ECT,,0.671617,-0.0074358,0.000424,,,,,,,,,,,,0.873079,1.466883,From .dat files included with MASControl2 +Refg-kW-fPLR,Refrigeration,Quadratic,,PLR,,0.0383,1.08,-0.116129,,,,,,,,,,,,0.1,1.2,From .dat files included with MASControl2 +Refg-kW2-fECT-T1,Refrigeration,Quadratic,,ECT,,0.753416,-0.0212148,0.000739,,,,,,,,,,,,0.850358,1.747334,From .dat files included with MASControl2 +Refg-kW2-fECT-T2,Refrigeration,Quadratic,,ECT,,1.00323,-0.0290574,0.000765,,,,,,,,,,,,0.859029,1.592964,From .dat files included with MASControl2 +Refg-kW2-fECT-T3,Refrigeration,Quadratic,,ECT,,0.671617,-0.0074358,0.000424,,,,,,,,,,,,0.873079,1.466883,From .dat files included with MASControl2 +Residential Fix Vol-Fan EIR,FanEIR-FPLR,Linear,EIRRatio,PLR,,1,0,,,,,,,,,,,,,,,From .dat files included with MASControl2 +Residential Var Vol-Fan EIR,FanEIR-FPLR,Cubic,EIRRatio,PLR,,0.000281,-0.0579,0.586,0.471,,,,,,,,,,,,,From .dat files included with MASControl2 +RestaurantFastFood Kitchen_Case:1_WALKINFREEZERSingleShelfHorizontal_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.0236,0.0006,0,0,,,,,,,-35,20,,,,,From Prototype Buildings +RestaurantFastFood Kitchen_Case:2_SELFCONTAINEDDISPLAYCASEMultiShelfVertical_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,6.02558E-05,1.23732E-06,,,,,,,-35,20,,,,,From Prototype Buildings +RESVVT-Bypass-Factor-fAirflow,ResidentialVVVT,Quadratic,QRatio,Airflow,,-0.254,1.22,0.036,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +RESVVT-Bypass-Factor-fEWB&EDB,ResidentialVVVT,BiQuadratic,QRatio,EWB,EDB,0.85086272,0.014256792,0.000184,-0.014759136,-0.00000548,0.000487,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +RESVVT-Cool-Cap-fEWB&OAT,ResidentialVVVT,BiQuadratic,QRatio,EWB,OAT,0.47523136,0.04006368,0.000226,-0.000847152,-0.00000732,-0.000447,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +RESVVT-Cool-Cap-fRPM&OAT,ResidentialVVVT,BiQuadratic,QRatio,RPM,OAT,-686.394,-427.2546283,-66.38563967,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 +RESVVT-Cool-CondFan-fPLR&OAT,ResidentialVVVT,BiQuadratic,,PLR,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 +RESVVT-Cool-CycleLoss-fPLR,ResidentialVVVT,Linear,QRatio,PLR,,0.7,0.3,,,,,,,,,,,,,,,From .dat files included with MASControl2 +RESVVT-Cool-EIR-fEWB&OAT,ResidentialVVVT,BiQuadratic,EIRRatio,EWB,OAT,0.63153792,-0.012168288,0.000509,0.015536304,0.000273,-0.000679,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +RESVVT-Cool-EIR-fPLR,ResidentialVVVT,Linear,EIRRatio,PLR,,0,1,,,,,,,,,,,,,,,From .dat files included with MASControl2 +RESVVT-Cool-EIR-fRPM&OAT,ResidentialVVVT,BiQuadratic,EIRRatio,RPM,OAT,35.1027,10.50422626,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 +RESVVT-Cool-EIR-LoSpeed-fEWB&OAT,ResidentialVVVT,BiQuadratic,EIRRatio,EWB,OAT,0.77672128,-0.034271136,0.000784,0.01465956,0.000489,-0.000752,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +RESVVT-Cool-Waste-Heat-fEWB&OAT,ResidentialVVVT,BiLinear,QRatio,EWB,OAT,1,0,0,,,,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +RESVVT-Cool-Waste-Heat-fRPM&OAT,ResidentialVVVT,BiQuadratic,QRatio,RPM,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 +RESVVT-Heat-Cap-fEDB&OAT,ResidentialVVVT,BiQuadratic,QRatio,EDB,OAT,0.7716,0,0,0.02754,0,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 +RESVVT-Heat-Cap-fRPM&OAT,ResidentialVVVT,BiQuadratic,QRatio,RPM,OAT,-483.189,-303.9732093,-47.69188125,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 +RESVVT-Heat-CondFan-fPLR&OAT,ResidentialVVVT,BiQuadratic,,PLR,OAT,1,0,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 +RESVVT-Heat-CycleLoss-fPLR,ResidentialVVVT,Linear,QRatio,PLR,,0.75,0.25,,,,,,,,,,,,,,,From .dat files included with MASControl2 +RESVVT-Heat-EIR-fEDB&OAT,ResidentialVVVT,BiQuadratic,EIRRatio,EDB,OAT,1.1544,0,0,-0.02448,0.000729,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 +RESVVT-Heat-EIR-fPLR,ResidentialVVVT,Linear,EIRRatio,PLR,,0,1,,,,,,,,,,,,,,,From .dat files included with MASControl2 +RESVVT-Heat-EIR-fRPM&OAT,ResidentialVVVT,BiQuadratic,EIRRatio,RPM,OAT,31.9068,9.520648707,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 +RESVVT-Heat-EIR-LoSpeed-fEDB&OAT,ResidentialVVVT,BiQuadratic,EIRRatio,EDB,OAT,1.25435136,0,0,-0.040685472,0.001209784,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 +RESVVT-Heat-Waste-Heat-fEDB&OAT,ResidentialVVVT,BiLinear,QRatio,EDB,OAT,1,0,0,,,,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 +RESVVT-Heat-Waste-Heat-fRPM&OAT,ResidentialVVVT,BiQuadratic,QRatio,RPM,OAT,1,0,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 +RESVVT-Sens-Cap-fEWB&OAT,ResidentialVVVT,BiLinear,QRatio,EWB,OAT,2.78672,-0.08208,-0.005292,,,,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +RESYS-Bypass-Factor-fAirflow,Residential#1,Quadratic,QRatio,Airflow,,-3.01,6.59,-2.57,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +RESYS-Bypass-Factor-fEWB&EDB,Residential#1,BiQuadratic,QRatio,EWB,EDB,-1.1641344,0.20453184,-0.000603,-0.03036096,0.00036,-0.001464804,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +RESYS-Bypass-Factor-fPLR,ResidentialVVVT,Linear,QRatio,PLR,,1,0,,,,,,,,,,,,,,,From .dat files included with MASControl2 +RESYS-Cool-Cap-fEWB&OAT,Residential#1,BiQuadratic,QRatio,EWB,OAT,0.7665024,0.01076904,-0.0000415,0.00133848,-0.000261,0.000457,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +RESYS-Cool-EIR-fEWB&OAT,Residential#1,BiQuadratic,EIRRatio,EWB,OAT,0.29770688,0.04314528,-0.000748,0.005972688,0.000482,-0.000956,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +RESYS-Cool-EIR-fPLR,,Cubic,EIRRatio,PLR,,0.0000626,1.18,-0.202,0.0263344,,,,,,,,,,,,,From .dat files included with MASControl2 +RESYS-Heat-Cap-fEDB&OAT,Residential#1,BiQuadratic,QRatio,EDB,OAT,0.7516064,0,0,0.02799072,0.00019,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 +RESYS-Heat-EIR-fEDB&OAT,Residential#1,BiQuadratic,EIRRatio,EDB,OAT,1.231072,0,0,-0.0334944,0.000739,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 +RESYS-Heat-EIR-fPLR,Residential#1,Cubic,EIRRatio,PLR,,0.0857,0.939,-0.1834361,0.15897022,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +RESYS-Sens-Cap-fAirflow,Residential#1,Linear,QRatio,Airflow,,0.6,0.4,,,,,,,,,,,,,,,From .dat files included with MASControl2 +RESYS-Sens-Cap-fEWB&OAT,Residential#1,BiQuadratic,QRatio,EWB,OAT,3.3127968,-0.1617552,0.00184356,0.01027584,-0.000156,-0.0000284,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +SAC Heating Coil PLF-FPLR,DX Heating Coil,Cubic,EIRRatio,QRatio,,0.8,0.2,0,0,,,,,,,0,1,,,,,From Prototype Buildings +SchoolPrimary Kitchen_ZN_1_FLR_1_Case:1_WALKINFREEZERSingleShelfHorizontal_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.0236,0.0006,0,0,,,,,,,-35,20,,,,,From Prototype Buildings +SchoolPrimary Kitchen_ZN_1_FLR_1_Case:2_SELFCONTAINEDDISPLAYCASEMultiShelfVertical_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,6.02558E-05,1.23732E-06,,,,,,,-35,20,,,,,From Prototype Buildings +ScrewAir-Cap-fCHWT&DBT,Screw,BiQuadratic,QRatio,CHWT,DBT,0.97878647,0.02387169,0.000587,-0.0000478,-0.000112,-0.00011,,,,,,,,,,,From .dat files included with MASControl2 +ScrewAir-EIR-fCHWT&DBT,Screw,BiQuadratic,EIRRatio,CHWT,DBT,0.6729704,-0.005730012,0.000702,-0.00119601,0.00044,-0.000699,,,,,,,,,,,From .dat files included with MASControl2 +ScrewAir-EIR-fPLR&dT-1Comp/Ckt,Screw,BiQuadratic,EIRRatio,PLR,dT,0.01040687,1.05183303,-0.09462459,0.002943774,-0.0000252,-0.001085832,,,,,,,,,,,From .dat files included with MASControl2 +ScrewAir-EIR-fPLR&dT-2Comp/Ckt,Screw,BiQuadratic,EIRRatio,PLR,dT,0.09611014,0.72898877,0.19517007,-0.000729072,0.00000667,-0.000175,,,,,,,,,,,From .dat files included with MASControl2 +ScrewH2O-Cap-fCHWT&ECT,Screw,BiQuadratic,QRatio,CHWT,ECT,1.07096667,0.02693502,0.000768,-0.00643302,-0.0000949,-0.0000659,,,,,,,,,,,From .dat files included with MASControl2 +ScrewH2O-EIR-fCHWT&ECT,Screw,BiQuadratic,EIRRatio,CHWT,ECT,0.59849788,-0.00123345,0.000563,0.001602738,0.000636,-0.001094148,,,,,,,,,,,From .dat files included with MASControl2 +ScrewH2O-EIR-fPLR&dT-1Comp/Ckt,Screw,BiQuadratic,EIRRatio,PLR,dT,-0.11699212,1.2635448,-0.2194667,0.005301648,0.0000547,-0.003346506,,,,,,,,,,,From .dat files included with MASControl2 +ScrewH2O-EIR-fPLR&dT-2Comp/Ckt,Screw,BiQuadratic,EIRRatio,PLR,dT,-0.27111483,1.49009538,-0.33198115,0.017556084,-0.000191,-0.008247186,,,,,,,,,,,From .dat files included with MASControl2 +ScrewRemote-Cap-fCHWT&SCT,Screw,BiQuadratic,QRatio,CHWT,SCT,1.16410009,0.048370122,0.000493,-0.002428218,-0.000109,-0.000269,,,,,,,,,,,From .dat files included with MASControl2 +ScrewRemote-EIR-fCHWT&SCT,Screw,BiQuadratic,EIRRatio,CHWT,SCT,0.79518287,-0.009101466,0.001707804,-0.015352632,0.000488,-0.000932,,,,,,,,,,,From .dat files included with MASControl2 +ScrewRemote-EIR-fPLR-1Comp/Ckt,Screw,Quadratic,EIRRatio,PLR,,0.07043035,1.01683199,-0.08726242,,,,,,,,,,,,,,From .dat files included with MASControl2 +ScrewRemote-EIR-fPLR-2Comp/Ckt,Screw,Quadratic,EIRRatio,PLR,,0.08138224,0.72724819,0.19136968,,,,,,,,,,,,,,From .dat files included with MASControl2 +ScrollChlrAirCoolCap-fCHW&OAT,Chiller,BiQuadratic,QRatio,CHWT,OAT,1.05229229,0.033560892,0.000215,-0.005180832,-0.0000442,-0.000215,,,,,,,,,,,From .dat files included with MASControl2 +ScrollChlrAirCoolEIR-fCHW&OAT,Chiller,BiQuadratic,EIRRatio,CHWT,OAT,0.58333562,-0.004036194,0.000468,-0.000224478,0.000481,-0.000682,,,,,,,,,,,From .dat files included with MASControl2 +ScrollChlrAirCoolEIR-fPLR,Chiller,Quadratic,EIRRatio,PLR,,0.03366649,0.53152555,0.43480802,,,,,,,,,,,,,,From .dat files included with MASControl2 +Si-Film_Spectral-fAirMass,PV-Module,Cubic,,AirMass,,0.95691782,0.04079713,-0.00869376,0.00042887,,,,,,,,,,,,,From .dat files included with MASControl2 +Single Shelf Horizontal Latent Energy Multiplier_After2004,Refrigerated Case,Cubic,,,,0.0236,0.0006,0,0,,,,,,,-35,20,,,,,From Reference Buildings +Single Shelf Horizontal Latent Energy Multiplier_Pre2004,Refrigerated Case,Cubic,,,,0.020376,0.00024378,0.0000114,1.811E-07,,,,,,,-35,20,,,,,From Reference Buildings +Single zone VAV fan,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.027827882,0.026583195,-0.0870687,1.03091975,,,,,,,0,1,,,0.1,,Baseline for System Type 11 from ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method +Small-CHW-Bypass-fAirflow,CHWCoils,Quadratic,QRatio,Airflow,,-0.718,1.91,-0.189,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Small-CHW-Coil-Bypass-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,1.09657216,0.001908,0.000369,-0.005647032,0.0000246,-0.000277,,,,,15.55556,29.44444,12.77778,29.44444,,,From .dat files included with MASControl2 +Small-CHW-Coil-Cap-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,-0.282048,-0.022212,0.0054432,0.0297216,0.000804,-0.0033372,,,,,15.55556,29.44444,12.77778,29.44444,,,From .dat files included with MASControl2 +Small-CHW-Sens-Cap-fAirflow,CHWCoils,Quadratic,QRatio,Airflow,,0.155,1.01,-0.16,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Small-CHW-Sens-Cap-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,-0.415152,-0.0405576,0.00140616,0.086508,0.000444,-0.00184356,,,,,12.77778,29.44444,12.77778,29.44444,,,From .dat files included with MASControl2 +Smooth_Optical-fAOI,PV-Module,Cubic,,AOI,,3.76248479,-0.15946805,0.00302191,-0.0000191,,,,,,,,,,,,,From .dat files included with MASControl2 +Split DX Coil EIR-FF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.1552,-0.1808,0.0256,,,,,,,,0.5,1.5,,,,,"From PNNL Prototype Buildings ApartmentMidRise, HotelSmall, Warehouse" +SpltAC1Sp_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 +SpltAC1Sp_BF_fT,BF_fT,BiQuadratic,,T,T,8.513632,-0.630072,0.0165888,-0.0450144,0.00107892,-0.0018954,,,,,,,,,0,3.33,From .dat files included with MASControl2 +SpltAC1Sp_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0.00007,1.23,-0.307,0.0756,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,0.00012,1.2,-0.261,0.0596,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.00007,1.17,-0.213,0.0438,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,0.67916,0.016938,0.00069336,0.0045576,-0.0000842,-0.00047628,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC1Sp_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.805,0.233,-0.038,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.827,0.203,-0.03,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.852,0.17,-0.0219,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.7311616,-0.10297296,0.00093636,0.00477864,-0.0000907,-0.000202824,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.7390464,-0.00778968,0.000128304,-0.00027,0.0006642,-0.000648,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC1Sp_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC1Sp_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC1Sp-ge45_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 +SpltAC1Sp-ge45_BF_fT,BF_fT,BiQuadratic,,T,T,16.900064,-1.747584,0.050544,0.1428912,0.00048924,-0.0090396,,,,,,,,,0,3.76,From .dat files included with MASControl2 +SpltAC1Sp-ge45_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0,1.18,-0.223,0.0468,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-ge45_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,0.00008,1.15,-0.183,0.0343,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-ge45_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.0001,1.12,-0.14,0.0225,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-ge45_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.2403136,-0.0346752,0.00187596,0.00106848,-0.000057,-0.0003564,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC1Sp-ge45_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.847,0.177,-0.0235,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-ge45_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.869,0.149,-0.0172,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-ge45_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.893,0.118,-0.0112,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-ge45_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.8260768,0.0199944,-0.00284148,-0.01422576,-0.0000577,0.00064152,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-ge45_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.093776,0.0674784,-0.00192132,-0.0031176,0.00067068,-0.0005832,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC1Sp-ge45_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC1Sp-ge45_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC1Sp-lt45_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 +SpltAC1Sp-lt45_BF_fT,BF_fT,BiQuadratic,,T,T,22.932224,-2.291616,0.063504,0.0800712,0.00076464,-0.0068364,,,,,,,,,0,3.3,From .dat files included with MASControl2 +SpltAC1Sp-lt45_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0,1.18,-0.223,0.0468,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-lt45_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,0.00008,1.15,-0.183,0.0343,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-lt45_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.0001,1.12,-0.14,0.0225,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-lt45_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.1299744,-0.0222336,0.0015228,-0.0000353,-0.0000434,-0.00032724,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC1Sp-lt45_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.847,0.177,-0.0235,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-lt45_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.869,0.149,-0.0172,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-lt45_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.893,0.118,-0.0112,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-lt45_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.4985024,0.0478512,-0.0034992,-0.01084968,-0.0000548,0.00047628,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-lt45_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.09712,0.0536256,-0.00144828,0.0040644,0.00062208,-0.000729,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC1Sp-lt45_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC1Sp-lt45_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC2SpHiSEER_BF_fFlow,BF_fFlow,Linear,,Flow,,1.75,-1578.5656,,,,,,,,,,,,,1,1.189,From .dat files included with MASControl2 +SpltAC2SpHiSEER_BF_fT,BF_fT,BiQuadratic,,T,T,20.03024,-1.922832,0.051516,0.086184,0.0011502,-0.0076788,,,,,,,,,0,3.92,From .dat files included with MASControl2 +SpltAC2SpHiSEER_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0.00635,1.12,-0.139,0.016,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC2SpHiSEER_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,-0.00144,1.12,-0.14,0.022,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC2SpHiSEER_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.00726,1.11,-0.132,0.0262,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC2SpHiSEER_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.5240096,-0.0665928,0.00299376,0.00162288,-0.0000651,-0.00048924,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC2SpHiSEER_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.923,0.153,-0.0156,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC2SpHiSEER_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.94,0.124,-0.0109,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC2SpHiSEER_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.959,0.0934,-0.00688,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC2SpHiSEER_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.54,0.0382752,-0.00297756,-0.0114912,-0.00010044,0.0005346,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC2SpHiSEER_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,-0.172512,0.1176624,-0.00324,-0.01152,0.00077112,-0.00057024,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC2SpHiSEER_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC2SpHiSEER_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC2SpLoSEER_BF_fFlow,BF_fFlow,Linear,,Flow,,1.75,-1578.5656,,,,,,,,,,,,,1,1.189,From .dat files included with MASControl2 +SpltAC2SpLoSEER_BF_fT,BF_fT,BiQuadratic,,T,T,10.820416,-1.041264,0.0254988,0.2290608,0.00062856,-0.0117612,,,,,,,,,0,5.76,From .dat files included with MASControl2 +SpltAC2SpLoSEER_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,-0.00016,1.12,-0.143,0.0206,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC2SpLoSEER_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,-0.00146,1.1,-0.119,0.0176,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC2SpLoSEER_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,0.00284,1.06,-0.0687,0.00523,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC2SpLoSEER_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.54887488,-0.0648072,0.00310068,-0.000425376,-0.0000255,-0.00060264,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC2SpLoSEER_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.856,0.121,-0.0124,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC2SpLoSEER_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.872,0.0941,-0.00752,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC2SpLoSEER_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.889,0.0695,-0.00646,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC2SpLoSEER_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.322048,-0.0286956,-0.00124092,-0.020124,-0.0000405,0.0006804,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC2SpLoSEER_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,-0.281376,0.1343088,-0.0036936,-0.0173736,0.00096552,-0.00075168,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC2SpLoSEER_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC2SpLoSEER_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltACEvap_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 +SpltACEvap_BF_fT,BF_fT,BiQuadratic,,T,T,16.06,-1.566,0.0405,1.75E-10,3.24E-12,3.24E-12,,,,,,,,,0,3.97,From .dat files included with MASControl2 +SpltACEvap_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0,1,0,0,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltACEvap_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,0,1,0,0,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltACEvap_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,0,1,0,0,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltACEvap_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,0.6302064,0.0171576,0.00069012,-0.00374688,0.000212544,-0.0005508,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltACEvap_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.94,0.06,0,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltACEvap_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.97,0.03,0,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltACEvap_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,1,0,0,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltACEvap_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.9516064,-0.0154008,-0.0012798,-0.00110088,0.000194724,-0.00054432,,,,,,,,,,,From .dat files included with MASControl2 +SpltACEvap_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,1.207232,-0.0528552,0.00053136,0.0261288,-0.00045684,0.0005508,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltACEvap_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltACEvap_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltHP1SpCom_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 +SpltHP1SpCom_BF_fT,BF_fT,BiQuadratic,,T,T,8.513632,-0.630072,0.0165888,-0.0450144,0.00107892,-0.0018954,,,,,,,,,0,3.33,From .dat files included with MASControl2 +SpltHP1SpCom_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0.00007,1.23,-0.307,0.0756,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpCom_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,0.00012,1.2,-0.261,0.0596,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpCom_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.00007,1.17,-0.213,0.0438,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpCom_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,0.67916,0.016938,0.00069336,0.0045576,-0.0000842,-0.00047628,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltHP1SpCom_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.805,0.233,-0.038,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpCom_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.827,0.203,-0.03,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpCom_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.852,0.17,-0.0219,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpCom_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.7311616,-0.10297296,0.00093636,0.00477864,-0.0000907,-0.000202824,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpCom_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.7390464,-0.00778968,0.000128304,-0.00027,0.0006642,-0.000648,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltHP1SpCom_HIR_fT,HIR_fT,BiQuadratic,,T,T,0.8186976,0.01406952,0.000117936,-0.01579104,0.000222264,-0.000300024,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltHP1SpCom_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0.85516576,-0.003631392,-0.00000619,0.02644704,0.00041148,-0.000141264,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltHP1SpRes_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 +SpltHP1SpRes_BF_fT,BF_fT,BiQuadratic,,T,T,8.513632,-0.630072,0.0165888,-0.0450144,0.00107892,-0.0018954,,,,,,,,,0,3.33,From .dat files included with MASControl2 +SpltHP1SpRes_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0.00007,1.23,-0.307,0.0756,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpRes_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,0.00012,1.2,-0.261,0.0596,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpRes_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.00007,1.17,-0.213,0.0438,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpRes_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,0.67916,0.016938,0.00069336,0.0045576,-0.0000842,-0.00047628,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltHP1SpRes_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.805,0.233,-0.038,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpRes_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.827,0.203,-0.03,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpRes_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.852,0.17,-0.0219,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpRes_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.7311616,-0.10297296,0.00093636,0.00477864,-0.0000907,-0.000202824,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpRes_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.7390464,-0.00778968,0.000128304,-0.00027,0.0006642,-0.000648,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltHP1SpRes_HIR_fT,HIR_fT,BiQuadratic,,T,T,0.9003872,0.01108728,0.0001701,-0.02579472,0.0008424,-0.000290628,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltHP1SpRes_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0.9303344,-0.0064656,0.0000177,0.02813472,-0.00000551,-0.000208656,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltHP2Sp_BF_fFlow,BF_fFlow,Linear,,Flow,,1.75,-1578.5656,,,,,,,,,,,,,1,1.189,From .dat files included with MASControl2 +SpltHP2Sp_BF_fT,BF_fT,BiQuadratic,,T,T,20.03024,-1.922832,0.051516,0.086184,0.0011502,-0.0076788,,,,,,,,,0,3.92,From .dat files included with MASControl2 +SpltHP2Sp_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0.00635,1.12,-0.139,0.016,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP2Sp_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,-0.00144,1.12,-0.14,0.022,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP2Sp_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.00726,1.11,-0.132,0.0262,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP2Sp_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.5240096,-0.0665928,0.00299376,0.00162288,-0.0000651,-0.00048924,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltHP2Sp_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.923,0.153,-0.0156,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP2Sp_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.94,0.124,-0.0109,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP2Sp_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.959,0.0934,-0.00688,,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP2Sp_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.54,0.0382752,-0.00297756,-0.0114912,-0.00010044,0.0005346,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP2Sp_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,-0.172512,0.1176624,-0.00324,-0.01152,0.00077112,-0.00057024,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltHP2Sp_HIR_fT,HIR_fT,BiQuadratic,,T,T,0.9272864,0.00802008,0.000201528,-0.02177136,0.000729,-0.000303264,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltHP2Sp_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0.8756304,-0.00466344,1.62E-14,0.02912976,0.00012636,-0.000163296,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SteamTurbine-Flow-fPSIG,SteamTurbineGen,BiQuadratic,QRatio,PSIG,PSIG,38.79236,-0.0000307,1.11E-11,0.000147951,1.93E-11,-7.36E-11,,,,,,,,,18,100,From .dat files included with MASControl2 +SteamTurbine-HIR-fPLR,SteamTurbineGen,Quadratic,,PLR,,0.12838545,0.90049523,-0.02888074,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Stippled_Optical-fAOI,PV-Module,Cubic,,AOI,,4.70208168,-0.21138079,0.00393233,-0.000024,,,,,,,,,,,,,From .dat files included with MASControl2 +SWH-EFFFPLR-NECB2011,Water Heater,Cubic,FIRRatio,QRatio,,0.7576,1.0071,-1.4443,0.6844,,,,,,,0,1,,,,,From NECB 2011 +Tower_Fan_Curve,,Cubic,,,,0,0,0,1,,,,,,,0,1,,,,,From Prototype Buildings +Transformer-Loss-fPLR,ElecMeters,Linear,QRatio,PLR,,0.1,0.9,,,,,,,,,,,,,,,From .dat files included with MASControl2 +Two-Speed Fan EIR fPLR,FanEIR-FPLR,Linear,,PLR,,-0.764706,1.764706,,,,,,,,,,,,,0.4,,From .dat files included with MASControl2 +TwoSpeedFan,FanEIR-FPLR,Cubic,EIRRatio,PLR,,0.000281,-0.0579,0.586,0.471,,,,,,,,,,,,,From .dat files included with MASControl2 +Typical VSD Fan,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.047182815,0.130541742,-0.117286942,0.940313747,,,,,,,0,1,,,0.1,,"From California Energy Commision, ""Advanced Variable Air Volume System Design Guide,"" October 2003" +TypicalCyclingAC-EIR-fPLR,CyclingAC,Cubic,EIRRatio,PLR,,0.0000626,1.17517,-0.201513,0.0263344,,,,,,,,,,,,,From .dat files included with MASControl2 +Vane Axial w Var Pitch FPLR,FanEIR-FPLR,Quadratic,,PLR,,0.212048,-0.569286,1.345238,,,,,,,,,,,,0.15,1,From .dat files included with MASControl2 +Variable Speed Drive FPLR,FanEIR-FPLR,Quadratic,,PLR,,0.219762,-0.874784,1.652597,,,,,,,,,,,,0.1,1,From .dat files included with MASControl2 +VarVolFan-AFBIFanCurve-NECB2011-FPLR,Fan,Cubic,PwrRatio,FlowRatio,,-2.4176,9.5874,-11.559,5.4009,,,,,,,0.68,1,,,,,From NECB 2011 +VarVolFan-AFBIInletVanes-NECB2011-FPLR,Fan,Cubic,PwrRatio,FlowRatio,,-4.1457,16.803,-19.471,7.8488,,,,,,,0.5,1,,,,,From NECB 2011 +VarVolFan-FCInletVanes-NECB2011-FPLR,Fan,Cubic,PwrRatio,FlowRatio,,-0.3477,4.0976,-5.0024,2.268,,,,,,,0.22,1,,,,,From NECB 2011 +VarVolFan-VSD-NECB2011-FPLR,Fan,Cubic,PwrRatio,FlowRatio,,0.1389,1.7699,-1.615,0.6996,,,,,,,0.04,1,,,,,From NECB 2011 +VFD-Loss-fPLR,Pumps,Linear,QRatio,PLR,,0.6,0.4,,,,,,,,,,,,,,,From .dat files included with MASControl2 +VRF-HP-Resys-ClCap-fSST&ODB,CondUnit,BiQuadratic,QRatio,SST,ODB,1.26588416,0,0,-0.007582032,-0.00000214,0,,,,,,,,,,,From .dat files included with MASControl2 +VRF-HP-Resys-ClEIR-fSST&ODB,CondUnit,BiQuadratic,EIRRatio,SST,ODB,0.384832,0,0,0.0092304,0.000238,0,,,,,,,,,,,From .dat files included with MASControl2 +VRF-HP-Resys-Crankcase-fPLR,CondUnit,Quadratic,,PLR,,1,-1.72,0.72,,,,,,,,,,,,,,From .dat files included with MASControl2 +VRF-HP-Resys-Cycle-fPLR,CondUnit,Linear,QRatio,PLR,,0.898,0.102,,,,,,,,,,,,,,,From .dat files included with MASControl2 +VRF-HP-Resys-HtCap-fSCT&OWB,CondUnit,BiQuadratic,QRatio,SCT,OWB,0.89783456,0,0,0.016707888,0.000000616,0,,,,,,,,,,,From .dat files included with MASControl2 +VRF-HP-Resys-HtEIR-fSCT&OWB,CondUnit,BiQuadratic,EIRRatio,SCT,OWB,1.0525344,0,0,-0.00815688,-0.0000872,0,,,,,,,,,,,From .dat files included with MASControl2 +VSD-TWR-FAN-FPLR,Cooling Tower,Cubic,,,,0.33162901,-0.88567609,0.60556507,0.9484823,,,,,,,0,1,,,,,From PNNL PRM Reference Manual +Water-Cooled-Bypass-fAirflow,"DXCooling,WCC",Cubic,QRatio,Airflow,,0.9,-3.73,7.37,-3.54,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Water-Cooled-Bypass-fEWB&EWT,"DXCooling,WCC",BiQuadratic,QRatio,EWB,EWT,-5.51104768,0.73563552,-0.0185004,0.142520616,0.000942,-0.010213452,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +Water-Cooled-Cool-Cap-fEWB&EWT,"DXCooling,WCC",BiQuadratic,QRatio,EWB,EWT,0.8254384,0.00574416,0.000735,-0.00310374,-0.0000146,-0.000194,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +Water-Cooled-EIR-fEWB&EWT,"DXCooling,WCC",BiQuadratic,EIRRatio,EWB,EWT,0.0985984,0.062604,-0.00184356,0.01183032,0.000292,-0.000395,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +Water-Cooled-EIR-fPLR,"DXCooling,WCC",Cubic,EIRRatio,PLR,,0.201,-0.0312,1.9504979,-1.1205104,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 +Water-Cooled-Sens-Cap-fEWB&EWT,"DXCooling,WCC",BiQuadratic,QRatio,EWB,EWT,2.1542784,-0.0242784,-0.00148716,-0.00829548,-0.0000296,0.000272,,,,,12.77778,29.44444,10,46.11111,,,From .dat files included with MASControl2 +WaterCooled_Centrifugal_CAPFT_NECB2011,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.707908,-0.00200657,-0.00259605,0.0300588,-0.00105643,0.0020457,,,,,5,10,24,35,,,From NECB 2011 +WaterCooled_Centrifugal_Chiller_150TO300_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_150TO300_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_150TO300_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.7600172,0.0147432,0.0002144,0.0207218,-0.0006425,0.0008007,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.6772577,0.0117857,-0.0001967,0.0014414,0.0003005,-0.0006807,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.536234,0.005581,-0.0013654,0.0488966,-0.0012018,0.0010523,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,1.0821822,0.0042977,-0.0013182,-0.0260781,0.0008256,-0.0006013,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_300TO600_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_300TO600_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_AllCapacities_2004_2007_2010_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010. EIRFPLR curve is identical for all WaterCooled Chillers" +WaterCooled_Centrifugal_Chiller_GT150_2004_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.7600172,0.0147432,0.0002144,0.0207218,-0.0006425,0.0008007,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_GT150_2004_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.6772577,0.0117857,-0.0001967,0.0014414,0.0003005,-0.0006807,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_GT300_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_GT600_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_GT600_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_LT150_2004_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.7446451,0.0114858,0.0000148,0.022401,-0.000688,0.0009839,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.772877,0.022101,-0.0000799,-0.0070045,0.0004763,-0.0010612,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_LT150_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_LT150_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_EIRFPLR_NECB2011,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.171493,0.588202,0.237373,,,,,,,,0,1,,,,,From NECB 2011 +WaterCooled_Centrifugal_EIRFT_NECB2011,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.560523,-0.0137816,6.56424E-05,0.0132194,0.000268596,-0.000501131,,,,,5,10,24,35,,,From NECB 2011 +WaterCooled_PositiveDisplacement_Chiller_150TO300_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_150TO300_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_150TO300_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_2004_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.906115,0.029227,-0.0003647,-0.0009709,-0.0000905,0.0002527,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_2004_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.3617105,-0.0229833,0.0009519,0.0131889,0.0003752,-0.0007059,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_2010_PathB_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.9061171,0.0292267,-0.0003665,-0.0009698,-0.0000907,0.0002535,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_2010_PathB_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.3617782,-0.0230016,0.0009672,0.0131801,0.0003761,-0.0007121,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_75TO150_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_75TO150_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_75TO150_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.906115,0.0292277,-0.0003647,-0.0009709,-0.0000905,0.0002527,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.3773115,-0.0229032,0.0016504,0.0118156,0.0004345,-0.0010132,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_GT300_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_GT300_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_GT300_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.906115,0.0292277,-0.0003647,-0.0009709,-0.0000905,0.0002527,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.3617105,-0.0229833,0.0009519,0.0131889,0.0003752,-0.0007059,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_LT75_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_LT75_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_LT75_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Reciprocating_CAPFT_NECB2011,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.03031,0.0334698,0.00023639,-0.00729587,-0.000023166,-0.000148943,,,,,5,10,24,35,,,From NECB 2011 +WaterCooled_Reciprocating_EIRFPLR_NECB2011,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.081441,0.419271,0.499396,,,,,,,,0,1,,,,,From NECB 2011 +WaterCooled_Reciprocating_EIRFT_NECB2011,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.499699,-0.0130841,0.000266425,0.0165925,0.000185393,-0.000375646,,,,,5,10,24,35,,,From NECB 2011 +WaterCooled_Screw_CAPFT_NECB2011,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.812998,-0.0142532,-0.00161799,0.0263844,-0.00091543,0.00169601,,,,,5,10,24,35,,,From NECB 2011 +WaterCooled_Screw_EIRFPLR_NECB2011,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.330188,0.235543,0.460708,,,,,,,,0,1,,,,,From NECB 2011 +WaterCooled_Screw_EIRFT_NECB2011,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.638103,0.00630158,0.00092327,-0.00455294,0.000825682,-0.00156152,,,,,5,10,24,35,,,From NECB 2011 +WaterCooled_Scroll_CAPFT_NECB2011,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.94418,0.0337102,9.75564E-05,-0.00322114,-4.91832E-05,-0.000177584,,,,,5,10,24,35,,,From NECB 2011 +WaterCooled_Scroll_EIRFPLR_NECB2011,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.04412,0.640367,0.319555,,,,,,,,0,1,,,,,From NECB 2011 +WaterCooled_Scroll_EIRFT_NECB2011,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.727393,-0.0118922,0.000541177,0.00187934,0.000473461,-0.000711472,,,,,5,10,24,35,,,From NECB 2011 +WC Screw Default 90.1-2004 Cap_fTWC,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.906115,0.0292277,-0.0003647,-0.0009709,-0.0000905,0.0002527,,,,,0,20,0,50,,,From RefBldgLargeOfficePost1980 & Pre1980 +WC Screw Default 90.1-2004 EIR_fT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.3617105,-0.0229833,-0.0009519,0.0131889,0.0003752,-0.0007059,,,,,0,20,0,50,,,From RefBldgLargeOfficePost1980 % Pre1980 +WC Screw GTE 300tons Default 90.1-2004 EIR_fPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.2737954,0.02822257,-8.09766E-05,0.9612284,0.3029741,-0.02421933,0,-0.03885224,0,0,18.54,31.63,0.2,1.02,,,From RefBldgLargeOfficePost1980 & Pre1980 +WC_PD_2004_CAPFT,,BiQuadratic,,,,0.906115,0.0292277,-0.0003647,-0.0009709,-0.0000905,0.0002527,,,,,5,10,17.78,46.11,,,From PNNL Prototype Hospital +WC_PD_2010_PB_CAPFT,,BiQuadratic,,,,0.9061171,0.0292267,-0.0003665,-0.0009698,-0.0000907,0.0002535,,,,,5,10,17.78,46.11,,,From PNNL Prototype OfficeLarge +WC_PD_2010_PB_EIRFT,,BiQuadratic,,,,0.3617782,-0.0230016,0.0009672,0.0131801,0.0003761,-0.0007121,,,,,5,10,17.78,46.11,,,From PNNL Prototype OfficeLarge +MT_compressor_power,Refrigeration,BiCubic,Power,Suction T,Discharge T,7438.92229,-269.59756,-9.8561045,553.57326,-3.3858896,14.8657878,-0.1007963,0.00982279,0.09736236,-0.039675217,-23.3,7.2,10,60,,,From AEDG +MT_compressor_capacity,Refrigeration,BiCubic,Capacity,Suction T,Discharge T,151166.436,5266.34789,60.6727151,-1851.5594,5.73132755,-46.927717,0.1364012,-0.0356979,-0.403054,-0.039290478,-23.3,-7.2,10,60,,,From AEDG +MT_compressor_capacity_smallandold,Refrigeration,BiCubic,Capacity,Suction T,Discharge T,15000,541.8,7.285,-118,-0.3645,-3.05,0.0344,0.00225,-0.03927,-0.007307,-17.8,4.4,10,48.9,,,From EP DataSets +MT_compressor_power_smallandold,Refrigeration,BiCubic,Power,Suction T,Discharge T,483.6,-53.2,-1.384,56.19,0.003688,1.439,-0.008268,-0.00281,0.007222,0.006025,-17.8,4.4,10,48.9,,,From EP DataSets +LT_compressor_capacity_smallandold,Refrigeration,BiCubic,Capacity,Suction T,Discharge T,23500,816.7,10.7,-28.24,0.1131,-0.4553,0.05604,-0.00412,-0.006728,0.006782,-40,-17.8,10,48.9,,,From EP DataSets +LT_compressor_power_smallandold,Refrigeration,BiCubic,Power,Suction T,Discharge T,4018,95,1.507,5.705,1.247,-1.381,0.01277,-0.007518,-0.02424,0.02917,-40,-17.8,10,48.9,,,From EP DataSets +Glass Door Latent Curve Case,Refrigeration,Cubic,,,,0.3379,0.0309,0.0005,0.00004,,,,,,,-55,55,,,,,From AEDG +Coffin Latent Curve Case,Refrigeration,Cubic,,,,0.3379,0.0309,0.0005,0.00004,,,,,,,-55,55,,,,,From AEDG +Open Latent Curve Case,Refrigeration,Cubic,,,,-0.0187,0.0458,0.0011,0.00005,,,,,,,-55,55,,,,,From AEDG +Glass Door Defrost Curve Walkin,Refrigeration,Cubic,,,,0.3475,0.0296,0.0007,0.00003,,,,,,,-55,55,,,,,From AEDG +Coffin Defrost Curve Walkin,Refrigeration,Cubic,,,,0.3475,0.0296,0.0007,0.00003,,,,,,,-55,55,,,,,From AEDG +Open Defrost Curve Walkin,Refrigeration,Cubic,,,,0.0572,0.0461,0.0004,0.00006,,,,,,,-55,55,,,,,From AEDG +Refrigeration Case Latent Credit Curve,Refrigeration,Cubic,,,,0.026526281,0.001078032,6.02558E-05,1.23732E-06,,,,,,,-35,20,,,,, diff --git a/data/openstudio_standards_data/database_files/support_standard_templates.csv b/data/openstudio_standards_data/database_files/support_standard_templates.csv new file mode 100644 index 0000000000..38a317f247 --- /dev/null +++ b/data/openstudio_standards_data/database_files/support_standard_templates.csv @@ -0,0 +1,3 @@ +template,lighting_standard,lighting_standard_table,ventilation_standard,ventilation_standard_table +90.1-2019,ASHRAE 90.1-2019,level_3_lighting_90_1_2019,ASHRAE 62.1-2019,level_3_ventilation_90_1_2019 +90.1-2004,ASHRAE 90.1-2004,level_3_lighting_90_1_2004,ASHRAE 62.1-2004,level_3_ventilation_90_1_2004 diff --git a/data/openstudio_standards_data/database_files/support_ventilation_space_type_name_tags.csv b/data/openstudio_standards_data/database_files/support_ventilation_space_type_name_tags.csv new file mode 100644 index 0000000000..071f84481d --- /dev/null +++ b/data/openstudio_standards_data/database_files/support_ventilation_space_type_name_tags.csv @@ -0,0 +1,111 @@ +ventilation_space_type_name +correctional_facilities_cell +correctional_facilities_dayroom +correctional_facilities_guard_stations +correctional_facilities_booking_waiting +educational_facilities_daycare +educational_facilities_classroom_young +educational_facilities_classroom_old +educational_facilities_lecture_classroom +educational_facilities_lecture_hall +educational_facilities_art_classroom +educational_facilities_science_laboratories +educational_facilities_wood_metal_shop +educational_facilities_computer_lab +educational_facilities_media_center +educational_facilities_music_theater_dance +educational_facilities_multiuse_assembly +educational_facilities_daycare_sickroom +educational_facilities_libraries +educational_facilities_university_college_laboratories +food_beverage_service_restaurant_dining_rooms +food_beverage_service_cafeteria_fast_food_dining +food_beverage_service_bars_cocktail_lounges +food_beverage_service_kitchen +general_conference_meeting +general_conference_corridors +general_conference_storage_rooms +general_break_rooms +general_coffee_stations +hotels_motels_resorts_dormitories_bedroom_living_room +hotels_motels_resorts_dormitories_barracks_sleeping_areas +hotels_motels_resorts_dormitories_lobbies_prefunction +hotels_motels_resorts_dormitories_multi_purpose_assembly +hotels_motels_resorts_dormitories_laundry_rooms +hotels_motels_resorts_dormitories_laundry_rooms_w_dwelling_units +office_buildings_office_space +office_buildings_reception_areas +office_buildings_telephone_data_entry +office_buildings_main_entry_lobbies +office_buildings_breakrooms +office_buildings_occupiable_storage_rooms +miscellaneous_spaces_bank_ vaults_safe_deposit +miscellaneous_spaces_computer +miscellaneous_spaces_pharmacy +miscellaneous_spaces_photo_studios +miscellaneous_spaces_shipping_receiving +miscellaneous_spaces_transportation_waiting +miscellaneous_spaces_warehouses +miscellaneous_spaces_banks_bank_lobbies +miscellaneous_spaces_freezer_refrigerated_spaces +miscellaneous_spaces_manufacturing_wo_hazardous_materials +miscellaneous_spaces_manufacturing_w_hazardous_materials +miscellaneous_spaces_sorting_packing_light_assembly +miscellaneous_spaces_telephone_closets +public_assembly_spaces_auditorium_seating_area +public_assembly_spaces_religious_workshop +public_assembly_spaces_courtrooms +public_assembly_spaces_legislative_chambers +public_assembly_spaces_libraries +public_assembly_spaces_lobbies +public_assembly_spaces_children_museums +public_assembly_spaces_museums_galleries +retail_sales +retail_mall_common_areas +retail_barbershop +retail_beauty_nail_salons +retail_pet_shops +retail_supermarket +retail_coin_operated_laundries +sports_entertainment_sports_arena +sports_entertainment_gym_stadium +sports_entertainment_spectator_areas +sports_entertainment_swimming +sports_entertainment_disco_dance_floors +sports_entertainment_health_club_aerobics_room +sports_entertainment_health_club_weight_rooms +sports_entertainment_bowling_alley +sports_entertainment_gambling_casinos +sports_entertainment_game_arcades +sports_entertainment_stages_studios +animal_facilities_animal_exam_room +animal_facilities_animal_imaging +animal_facilities_animal_operating_rooms +animal_facilities_animal_postoperative_recovery_room +animal_facilities_animal_preparation_rooms +animal_facilities_animal_procedure_room +animal_facilities_animal_surgery_scrub +animal_facilities_large_animal_holding_room +animal_facilities_necropsy +animal_facilities_small_animal_cage_room_static +animal_facilities_small_animal_cage_room_ventilated +outpatient_health_care_facilities_birthing_room +outpatient_health_care_facilities_class_1_imaging_rooms +outpatient_health_care_facilities_dental_operatory +outpatient_health_care_facilities_general_examination_room +outpatient_health_care_facilities_other_dental_treatment_areas +outpatient_health_care_facilities_physical_therapy_exercise_area +outpatient_health_care_facilities_physical_therapy_individual_room +outpatient_health_care_facilities_physical_therapeutic_pool_area +outpatient_health_care_facilities_prosthetics_orthotics_room +outpatient_health_care_facilities_psychiatric_consultation_room +outpatient_health_care_facilities_psychiatric_examination_room +outpatient_health_care_facilities_psychiatric_group_room +outpatient_health_care_facilities_psychiatric_seclusion_room +outpatient_health_care_facilities_speech_therapy_room +outpatient_health_care_facilities_urgent_care_examination_room +outpatient_health_care_facilities_urgent_care_observation_room +outpatient_health_care_facilities_urgent_care_treatment_room +outpatient_health_care_facilities_urgent_care_triage_room +transient_residential_common_corridors +transient_residential_dwelling_unit diff --git a/data/openstudio_standards_data/database_files/system_requirement_economizer_90_1.csv b/data/openstudio_standards_data/database_files/system_requirement_economizer_90_1.csv new file mode 100644 index 0000000000..1405f86a9d --- /dev/null +++ b/data/openstudio_standards_data/database_files/system_requirement_economizer_90_1.csv @@ -0,0 +1,497 @@ +template,climate_zone,data_center,capacity_limit,fixed_dry_bulb_high_limit_shutoff_temp,annotation +90.1-2004,ASHRAE 169-2006-1A,FALSE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-1A,TRUE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-1B,FALSE,,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-1B,TRUE,,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-2A,FALSE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-2A,TRUE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-2B,FALSE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-2B,TRUE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-3A,FALSE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-3A,TRUE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-3B,FALSE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-3B,TRUE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-3C,FALSE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-3C,TRUE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-4A,FALSE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-4A,TRUE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-4B,FALSE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-4B,TRUE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-4C,FALSE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-4C,TRUE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-5A,FALSE,135000,70,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-5A,TRUE,135000,70,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-5B,FALSE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-5B,TRUE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-5C,FALSE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-5C,TRUE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-6A,FALSE,135000,70,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-6A,TRUE,135000,70,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-6B,FALSE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-6B,TRUE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-7A,FALSE,135000,70,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-7A,TRUE,135000,70,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-7B,FALSE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-7B,TRUE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-8A,FALSE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-8A,TRUE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-8B,FALSE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-8B,TRUE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-1A,FALSE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-1A,TRUE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-1B,FALSE,,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-1B,TRUE,,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-2A,FALSE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-2A,TRUE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-2B,FALSE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-2B,TRUE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-3A,FALSE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-3A,TRUE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-3B,FALSE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-3B,TRUE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-3C,FALSE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-3C,TRUE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-4A,FALSE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-4A,TRUE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-4B,FALSE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-4B,TRUE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-4C,FALSE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-4C,TRUE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-5A,FALSE,135000,70,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-5A,TRUE,135000,70,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-5B,FALSE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-5B,TRUE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-5C,FALSE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-5C,TRUE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-6A,FALSE,135000,70,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-6A,TRUE,135000,70,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-6B,FALSE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-6B,TRUE,65000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-7A,FALSE,135000,70,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-7A,TRUE,135000,70,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-7B,FALSE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-7B,TRUE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-8A,FALSE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-8A,TRUE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-8B,FALSE,135000,75,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-8B,TRUE,135000,75,90.1-2004 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-1A,FALSE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-1A,TRUE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-1B,FALSE,,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-1B,TRUE,,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-2A,FALSE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-2A,TRUE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-2B,FALSE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-2B,TRUE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-3A,FALSE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-3A,TRUE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-3B,FALSE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-3B,TRUE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-3C,FALSE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-3C,TRUE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-4A,FALSE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-4A,TRUE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-4B,FALSE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-4B,TRUE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-4C,FALSE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-4C,TRUE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-5A,FALSE,135000,70,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-5A,TRUE,135000,70,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-5B,FALSE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-5B,TRUE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-5C,FALSE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-5C,TRUE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-6A,FALSE,135000,70,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-6A,TRUE,135000,70,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-6B,FALSE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-6B,TRUE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-7A,FALSE,135000,70,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-7A,TRUE,135000,70,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-7B,FALSE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-7B,TRUE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-8A,FALSE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-8A,TRUE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-8B,FALSE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-8B,TRUE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-1A,FALSE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-1A,TRUE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-1B,FALSE,,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-1B,TRUE,,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-2A,FALSE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-2A,TRUE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-2B,FALSE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-2B,TRUE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-3A,FALSE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-3A,TRUE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-3B,FALSE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-3B,TRUE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-3C,FALSE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-3C,TRUE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-4A,FALSE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-4A,TRUE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-4B,FALSE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-4B,TRUE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-4C,FALSE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-4C,TRUE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-5A,FALSE,135000,70,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-5A,TRUE,135000,70,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-5B,FALSE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-5B,TRUE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-5C,FALSE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-5C,TRUE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-6A,FALSE,135000,70,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-6A,TRUE,135000,70,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-6B,FALSE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-6B,TRUE,65000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-7A,FALSE,135000,70,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-7A,TRUE,135000,70,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-7B,FALSE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-7B,TRUE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-8A,FALSE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-8A,TRUE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-8B,FALSE,135000,75,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-8B,TRUE,135000,75,90.1-2007 Table 6.5.1 +90.1-2010,ASHRAE 169-2006-1A,TRUE,,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-1A,FALSE,,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-1B,TRUE,,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-1B,FALSE,,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-2A,TRUE,,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-2A,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-2B,TRUE,135000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-2B,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-3A,TRUE,,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-3A,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-3B,TRUE,65000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-3B,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-3C,TRUE,65000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-3C,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-4A,TRUE,,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-4A,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-4B,TRUE,65000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-4B,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-4C,TRUE,65000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-4C,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-5A,TRUE,135000,70,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-5A,FALSE,54000,70,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-5B,TRUE,65000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-5B,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-5C,TRUE,65000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-5C,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-6A,TRUE,135000,70,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-6A,FALSE,54000,70,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-6B,TRUE,65000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-6B,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-7A,TRUE,135000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-7A,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-7B,TRUE,135000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-7B,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-8A,TRUE,135000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-8A,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-8B,TRUE,135000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-8B,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-1A,TRUE,,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-1A,FALSE,,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-1B,TRUE,,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-1B,FALSE,,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-2A,TRUE,,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-2A,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-2B,TRUE,135000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-2B,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-3A,TRUE,,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-3A,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-3B,TRUE,65000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-3B,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-3C,TRUE,65000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-3C,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-4A,TRUE,,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-4A,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-4B,TRUE,65000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-4B,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-4C,TRUE,65000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-4C,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-5A,TRUE,135000,70,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-5A,FALSE,54000,70,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-5B,TRUE,65000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-5B,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-5C,TRUE,65000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-5C,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-6A,TRUE,135000,70,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-6A,FALSE,54000,70,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-6B,TRUE,65000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-6B,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-7A,TRUE,135000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-7A,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-7B,TRUE,135000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-7B,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-8A,TRUE,135000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-8A,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-8B,TRUE,135000,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-8B,FALSE,54000,75,90.1-2010 Table 6.5.1A +90.1-2013,ASHRAE 169-2006-1A,TRUE,,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-1A,FALSE,,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-1B,TRUE,,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-1B,FALSE,,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-2A,TRUE,,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-2A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-2B,TRUE,135000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-2B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-3A,TRUE,,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-3A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-3B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-3B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-3C,TRUE,65000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-3C,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-4A,TRUE,,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-4A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-4B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-4B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-4C,TRUE,65000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-4C,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-5A,TRUE,135000,70,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-5A,FALSE,54000,70,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-5B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-5B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-5C,TRUE,65000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-5C,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-6A,TRUE,135000,70,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-6A,FALSE,54000,70,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-6B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-6B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-7A,TRUE,135000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-7A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-7B,TRUE,135000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-7B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-8A,TRUE,135000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-8A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-8B,TRUE,135000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-8B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-1A,TRUE,,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-1A,FALSE,,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-1B,TRUE,,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-1B,FALSE,,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-2A,TRUE,,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-2A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-2B,TRUE,135000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-2B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-3A,TRUE,,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-3A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-3B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-3B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-3C,TRUE,65000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-3C,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-4A,TRUE,,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-4A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-4B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-4B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-4C,TRUE,65000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-4C,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-5A,TRUE,135000,70,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-5A,FALSE,54000,70,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-5B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-5B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-5C,TRUE,65000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-5C,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-6A,TRUE,135000,70,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-6A,FALSE,54000,70,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-6B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-6B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-7A,TRUE,135000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-7A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-7B,TRUE,135000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-7B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-8A,TRUE,135000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-8A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-8B,TRUE,135000,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-8B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 +90.1-2004,ASHRAE 169-2006-0A,FALSE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2006-0B,FALSE,,75,90.1-2004 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-0A,FALSE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2006-0B,FALSE,,75,90.1-2007 Table 6.5.1 +90.1-2010,ASHRAE 169-2006-0A,FALSE,,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2006-0B,FALSE,,75,90.1-2010 Table 6.5.1A +90.1-2013,ASHRAE 169-2006-0A,FALSE,,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2006-0B,FALSE,,75,90.1-2013 Table 6.5.1-1 +90.1-2004,ASHRAE 169-2013-0A,FALSE,,65,90.1-2004 Table 6.5.1 +90.1-2004,ASHRAE 169-2013-0B,FALSE,,75,90.1-2004 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-0A,FALSE,,65,90.1-2007 Table 6.5.1 +90.1-2007,ASHRAE 169-2013-0B,FALSE,,75,90.1-2007 Table 6.5.1 +90.1-2010,ASHRAE 169-2013-0A,FALSE,,75,90.1-2010 Table 6.5.1A +90.1-2010,ASHRAE 169-2013-0B,FALSE,,75,90.1-2010 Table 6.5.1A +90.1-2013,ASHRAE 169-2013-0A,FALSE,,75,90.1-2013 Table 6.5.1-1 +90.1-2013,ASHRAE 169-2013-0B,FALSE,,75,90.1-2013 Table 6.5.1-1 +90.1-2010,ASHRAE 169-2006-0A,TRUE,,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2006-0B,TRUE,,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-0A,TRUE,,75,90.1-2010 Table 6.5.1B +90.1-2010,ASHRAE 169-2013-0B,TRUE,,75,90.1-2010 Table 6.5.1B +90.1-2013,ASHRAE 169-2006-0A,TRUE,,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2006-0B,TRUE,,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-0A,TRUE,,75,90.1-2013 Table 6.5.1-2 +90.1-2013,ASHRAE 169-2013-0B,TRUE,,75,90.1-2013 Table 6.5.1-2 +90.1-2016,ASHRAE 169-2006-1A,TRUE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-1A,FALSE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-1B,TRUE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-1B,FALSE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-2A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-2A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-2B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-2B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-3A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-3A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-3B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-3B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-3C,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-3C,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-4A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-4A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-4B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-4B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-4C,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-4C,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-5A,TRUE,54000,70,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-5A,FALSE,54000,70,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-5B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-5B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-5C,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-5C,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-6A,TRUE,54000,70,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-6A,FALSE,54000,70,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-6B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-6B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-7A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-7A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-7B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-7B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-8A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-8A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-8B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-8B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-1A,TRUE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-1A,FALSE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-1B,TRUE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-1B,FALSE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-2A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-2A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-2B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-2B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-3A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-3A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-3B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-3B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-3C,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-3C,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-4A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-4A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-4B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-4B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-4C,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-4C,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-5A,TRUE,54000,70,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-5A,FALSE,54000,70,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-5B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-5B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-5C,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-5C,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-6A,TRUE,54000,70,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-6A,FALSE,54000,70,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-6B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-6B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-7A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-7A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-7B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-7B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-8A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-8A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-8B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-8B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-0A,FALSE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-0B,FALSE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-0A,FALSE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-0B,FALSE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-0A,TRUE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2006-0B,TRUE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-0A,TRUE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2016,ASHRAE 169-2013-0B,TRUE,,75,90.1-2016 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-1A,TRUE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-1A,FALSE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-1B,TRUE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-1B,FALSE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-2A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-2A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-2B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-2B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-3A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-3A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-3B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-3B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-3C,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-3C,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-4A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-4A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-4B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-4B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-4C,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-4C,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-5A,TRUE,54000,70,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-5A,FALSE,54000,70,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-5B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-5B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-5C,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-5C,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-6A,TRUE,54000,70,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-6A,FALSE,54000,70,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-6B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-6B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-7A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-7A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-7B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-7B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-8A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-8A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-8B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-8B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-1A,TRUE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-1A,FALSE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-1B,TRUE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-1B,FALSE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-2A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-2A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-2B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-2B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-3A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-3A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-3B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-3B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-3C,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-3C,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-4A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-4A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-4B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-4B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-4C,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-4C,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-5A,TRUE,54000,70,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-5A,FALSE,54000,70,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-5B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-5B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-5C,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-5C,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-6A,TRUE,54000,70,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-6A,FALSE,54000,70,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-6B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-6B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-7A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-7A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-7B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-7B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-8A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-8A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-8B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-8B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-0A,FALSE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-0B,FALSE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-0A,FALSE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-0B,FALSE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-0A,TRUE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2006-0B,TRUE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-0A,TRUE,,75,90.1-2019 Table 6.5.1.1.3 +90.1-2019,ASHRAE 169-2013-0B,TRUE,,75,90.1-2019 Table 6.5.1.1.3 diff --git a/data/openstudio_standards_data/database_files/system_requirement_energy_recovery_90_1.csv b/data/openstudio_standards_data/database_files/system_requirement_energy_recovery_90_1.csv new file mode 100644 index 0000000000..a06d3844d7 --- /dev/null +++ b/data/openstudio_standards_data/database_files/system_requirement_energy_recovery_90_1.csv @@ -0,0 +1,409 @@ +template,climate_zone,under_8000_hours,nontransient_dwelling,percent_oa_0_to_10,percent_oa_10_to_20,percent_oa_20_to_30,percent_oa_30_to_40,percent_oa_40_to_50,percent_oa_50_to_60,percent_oa_60_to_70,percent_oa_70_to_80,percent_oa_greater_than_80,enthalpy_recovery_ratio_design_conditions,enthalpy_recovery_ratio,annotation +90.1-2010,ASHRAE 169-2006-1A,,,,,,5500,4500,3500,2000,1000,0,, +90.1-2010,ASHRAE 169-2006-1B,,,,,,,,26000,12000,5000,4000,, +90.1-2010,ASHRAE 169-2006-2A,,,,,,5500,4500,3500,2000,1000,0,, +90.1-2010,ASHRAE 169-2006-2B,,,,,,,,26000,12000,5000,4000,, +90.1-2010,ASHRAE 169-2006-3A,,,,,,5500,4500,3500,2000,1000,0,, +90.1-2010,ASHRAE 169-2006-3B,,,,,,,,,,5000,5000,, +90.1-2010,ASHRAE 169-2006-3C,,,,,,,,,,5000,5000,, +90.1-2010,ASHRAE 169-2006-4A,,,,,,5500,4500,3500,2000,1000,0,, +90.1-2010,ASHRAE 169-2006-4B,,,,,,,,,,5000,5000,, +90.1-2010,ASHRAE 169-2006-4C,,,,,,,,,,5000,5000,, +90.1-2010,ASHRAE 169-2006-5A,,,,,,5500,4500,3500,2000,1000,0,, +90.1-2010,ASHRAE 169-2006-5B,,,,,,,,,,5000,5000,, +90.1-2010,ASHRAE 169-2006-5C,,,,,,,,26000,12000,5000,4000,, +90.1-2010,ASHRAE 169-2006-6A,,,,,,5500,4500,3500,2000,1000,0,, +90.1-2010,ASHRAE 169-2006-6B,,,,,,11000,5500,4500,3500,2500,1500,, +90.1-2010,ASHRAE 169-2006-7A,,,,,,2500,1000,0,0,0,0,, +90.1-2010,ASHRAE 169-2006-7B,,,,,,2500,1000,0,0,0,0,, +90.1-2010,ASHRAE 169-2006-8A,,,,,,2500,1000,0,0,0,0,, +90.1-2010,ASHRAE 169-2006-8B,,,,,,2500,1000,0,0,0,0,, +90.1-2010,ASHRAE 169-2013-1A,,,,,,5500,4500,3500,2000,1000,0,, +90.1-2010,ASHRAE 169-2013-1B,,,,,,,,26000,12000,5000,4000,, +90.1-2010,ASHRAE 169-2013-2A,,,,,,5500,4500,3500,2000,1000,0,, +90.1-2010,ASHRAE 169-2013-2B,,,,,,,,26000,12000,5000,4000,, +90.1-2010,ASHRAE 169-2013-3A,,,,,,5500,4500,3500,2000,1000,0,, +90.1-2010,ASHRAE 169-2013-3B,,,,,,,,,,5000,5000,, +90.1-2010,ASHRAE 169-2013-3C,,,,,,,,,,5000,5000,, +90.1-2010,ASHRAE 169-2013-4A,,,,,,5500,4500,3500,2000,1000,0,, +90.1-2010,ASHRAE 169-2013-4B,,,,,,,,,,5000,5000,, +90.1-2010,ASHRAE 169-2013-4C,,,,,,,,,,5000,5000,, +90.1-2010,ASHRAE 169-2013-5A,,,,,,5500,4500,3500,2000,1000,0,, +90.1-2010,ASHRAE 169-2013-5B,,,,,,,,,,5000,5000,, +90.1-2010,ASHRAE 169-2013-5C,,,,,,,,26000,12000,5000,4000,, +90.1-2010,ASHRAE 169-2013-6A,,,,,,5500,4500,3500,2000,1000,0,, +90.1-2010,ASHRAE 169-2013-6B,,,,,,11000,5500,4500,3500,2500,1500,, +90.1-2010,ASHRAE 169-2013-7A,,,,,,2500,1000,0,0,0,0,, +90.1-2010,ASHRAE 169-2013-7B,,,,,,2500,1000,0,0,0,0,, +90.1-2010,ASHRAE 169-2013-8A,,,,,,2500,1000,0,0,0,0,, +90.1-2010,ASHRAE 169-2013-8B,,,,,,2500,1000,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-1A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, +90.1-2013,ASHRAE 169-2006-1A,FALSE,,,2500,2000,1000,500,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-1B,TRUE,,,,,,,26000,12000,5000,4000,, +90.1-2013,ASHRAE 169-2006-1B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, +90.1-2013,ASHRAE 169-2006-2A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, +90.1-2013,ASHRAE 169-2006-2A,FALSE,,,2500,2000,1000,500,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-2B,TRUE,,,,,,,26000,12000,5000,4000,, +90.1-2013,ASHRAE 169-2006-2B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, +90.1-2013,ASHRAE 169-2006-3A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, +90.1-2013,ASHRAE 169-2006-3A,FALSE,,,2500,2000,1000,500,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-3B,TRUE,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2006-3B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, +90.1-2013,ASHRAE 169-2006-3C,TRUE,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2006-3C,FALSE,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2006-4A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, +90.1-2013,ASHRAE 169-2006-4A,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-4B,TRUE,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2006-4B,FALSE,,,2500,2000,1000,500,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-4C,TRUE,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2006-4C,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, +90.1-2013,ASHRAE 169-2006-5A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, +90.1-2013,ASHRAE 169-2006-5A,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-5B,TRUE,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2006-5B,FALSE,,,2500,2000,1000,500,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-5C,TRUE,,,,,,,26000,12000,5000,4000,, +90.1-2013,ASHRAE 169-2006-5C,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, +90.1-2013,ASHRAE 169-2006-6A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, +90.1-2013,ASHRAE 169-2006-6A,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-6B,TRUE,,,28000,26500,11000,5500,4500,3500,2500,1500,, +90.1-2013,ASHRAE 169-2006-6B,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-7A,TRUE,,,4500,4000,2500,1000,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-7A,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-7B,TRUE,,,4500,4000,2500,1000,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-7B,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-8A,TRUE,,,4500,4000,2500,1000,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-8A,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-8B,TRUE,,,4500,4000,2500,1000,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-8B,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-1A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, +90.1-2013,ASHRAE 169-2013-1A,FALSE,,,2500,2000,1000,500,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-1B,TRUE,,,,,,,26000,12000,5000,4000,, +90.1-2013,ASHRAE 169-2013-1B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, +90.1-2013,ASHRAE 169-2013-2A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, +90.1-2013,ASHRAE 169-2013-2A,FALSE,,,2500,2000,1000,500,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-2B,TRUE,,,,,,,26000,12000,5000,4000,, +90.1-2013,ASHRAE 169-2013-2B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, +90.1-2013,ASHRAE 169-2013-3A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, +90.1-2013,ASHRAE 169-2013-3A,FALSE,,,2500,2000,1000,500,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-3B,TRUE,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2013-3B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, +90.1-2013,ASHRAE 169-2013-3C,TRUE,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2013-3C,FALSE,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2013-4A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, +90.1-2013,ASHRAE 169-2013-4A,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-4B,TRUE,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2013-4B,FALSE,,,2500,2000,1000,500,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-4C,TRUE,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2013-4C,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, +90.1-2013,ASHRAE 169-2013-5A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, +90.1-2013,ASHRAE 169-2013-5A,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-5B,TRUE,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2013-5B,FALSE,,,2500,2000,1000,500,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-5C,TRUE,,,,,,,26000,12000,5000,4000,, +90.1-2013,ASHRAE 169-2013-5C,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, +90.1-2013,ASHRAE 169-2013-6A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, +90.1-2013,ASHRAE 169-2013-6A,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-6B,TRUE,,,28000,26500,11000,5500,4500,3500,2500,1500,, +90.1-2013,ASHRAE 169-2013-6B,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-7A,TRUE,,,4500,4000,2500,1000,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-7A,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-7B,TRUE,,,4500,4000,2500,1000,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-7B,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-8A,TRUE,,,4500,4000,2500,1000,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-8A,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-8B,TRUE,,,4500,4000,2500,1000,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-8B,FALSE,,,0,0,0,0,0,0,0,0,, +90.1-2016,ASHRAE 169-2006-1A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-1A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-1B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-1B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-2A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-2A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-2B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-2B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-3A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-3A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-3B,TRUE,,,,,,,,,,,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-3B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-3C,TRUE,,,,,,,,,,,Heating,0.5 +90.1-2016,ASHRAE 169-2006-3C,FALSE,,,,,,,,,,,Heating,0.5 +90.1-2016,ASHRAE 169-2006-4A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-4A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-4B,TRUE,,,,,,,,,,,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-4B,TRUE,,,,,,,,,,,Heating,0.5 +90.1-2016,ASHRAE 169-2006-4B,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-4B,FALSE,,,2500,2000,1000,500,140,120,100,80,Heating,0.5 +90.1-2016,ASHRAE 169-2006-4C,TRUE,,,,,,,,,,,Heating,0.5 +90.1-2016,ASHRAE 169-2006-4C,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 +90.1-2016,ASHRAE 169-2006-5A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-5A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-5B,TRUE,,,,,,,,,,,Heating,0.5 +90.1-2016,ASHRAE 169-2006-5B,FALSE,,,2500,2000,1000,500,140,120,100,80,Heating,0.5 +90.1-2016,ASHRAE 169-2006-5C,TRUE,,,,,,,26000,12000,5000,4000,Heating,0.5 +90.1-2016,ASHRAE 169-2006-5C,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 +90.1-2016,ASHRAE 169-2006-6A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-6A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-6B,TRUE,,,28000,26500,11000,5500,4500,3500,2500,1500,Heating,0.5 +90.1-2016,ASHRAE 169-2006-6B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2016,ASHRAE 169-2006-7A,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2016,ASHRAE 169-2006-7A,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2016,ASHRAE 169-2006-7B,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2016,ASHRAE 169-2006-7B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2016,ASHRAE 169-2006-8A,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2016,ASHRAE 169-2006-8A,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2016,ASHRAE 169-2006-8B,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2016,ASHRAE 169-2006-8B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2016,ASHRAE 169-2013-1A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-1A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-1B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-1B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-2A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-2A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-2B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-2B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-3A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-3A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-3B,TRUE,,,,,,,,,,,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-3B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-3C,TRUE,,,,,,,,,,,Heating,0.5 +90.1-2016,ASHRAE 169-2013-3C,FALSE,,,,,,,,,,,Heating,0.5 +90.1-2016,ASHRAE 169-2013-4A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-4A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-4B,TRUE,,,,,,,,,,,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-4B,TRUE,,,,,,,,,,,Heating,0.5 +90.1-2016,ASHRAE 169-2013-4B,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-4B,FALSE,,,2500,2000,1000,500,140,120,100,80,Heating,0.5 +90.1-2016,ASHRAE 169-2013-4C,TRUE,,,,,,,,,,,Heating,0.5 +90.1-2016,ASHRAE 169-2013-4C,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 +90.1-2016,ASHRAE 169-2013-5A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-5A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-5B,TRUE,,,,,,,,,,,Heating,0.5 +90.1-2016,ASHRAE 169-2013-5B,FALSE,,,2500,2000,1000,500,140,120,100,80,Heating,0.5 +90.1-2016,ASHRAE 169-2013-5C,TRUE,,,,,,,26000,12000,5000,4000,Heating,0.5 +90.1-2016,ASHRAE 169-2013-5C,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 +90.1-2016,ASHRAE 169-2013-6A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-6A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-6B,TRUE,,,28000,26500,11000,5500,4500,3500,2500,1500,Heating,0.5 +90.1-2016,ASHRAE 169-2013-6B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2016,ASHRAE 169-2013-7A,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2016,ASHRAE 169-2013-7A,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2016,ASHRAE 169-2013-7B,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2016,ASHRAE 169-2013-7B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2016,ASHRAE 169-2013-8A,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2016,ASHRAE 169-2013-8A,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2016,ASHRAE 169-2013-8B,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2016,ASHRAE 169-2013-8B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2006-1A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-1A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-1A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-1A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-1B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-1B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-1B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-1B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-2A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-2A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-2A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-2A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-2B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-2B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-2B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-2B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-3A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-3A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-3A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 +90.1-2019,ASHRAE 169-2006-3A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-3A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-3A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5 +90.1-2019,ASHRAE 169-2006-3B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-3B,TRUE,FALSE,,,,,,,,,,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-3B,TRUE,FALSE,,,,,,,,,,Heating,0.5 +90.1-2019,ASHRAE 169-2006-3B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-3B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-3B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 +90.1-2019,ASHRAE 169-2006-3C,TRUE,TRUE,,,,,,,,,,, +90.1-2019,ASHRAE 169-2006-3C,TRUE,FALSE,,,,,,,,,,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-3C,TRUE,FALSE,,,,,,,,,,Heating,0.5 +90.1-2019,ASHRAE 169-2006-3C,FALSE,TRUE,,,,,,,,,,, +90.1-2019,ASHRAE 169-2006-3C,FALSE,FALSE,,,,,,,,,,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-3C,FALSE,FALSE,,,,,,,,,,Heating,0.5 +90.1-2019,ASHRAE 169-2006-4A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-4A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-4A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 +90.1-2019,ASHRAE 169-2006-4A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-4A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-4A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2006-4B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-4B,TRUE,FALSE,,,,,,,,,,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-4B,TRUE,FALSE,,,,,,,,,,Heating,0.5 +90.1-2019,ASHRAE 169-2006-4B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-4B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-4B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5 +90.1-2019,ASHRAE 169-2006-4C,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-4C,TRUE,FALSE,,,,,,,,,,Heating,0.5 +90.1-2019,ASHRAE 169-2006-4C,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-4C,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 +90.1-2019,ASHRAE 169-2006-5A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-5A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-5A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 +90.1-2019,ASHRAE 169-2006-5A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-5A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-5A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2006-5B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-5B,TRUE,FALSE,,,,,,,,,,Heating,0.5 +90.1-2019,ASHRAE 169-2006-5B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-5B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5 +90.1-2019,ASHRAE 169-2006-5C,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-5C,TRUE,FALSE,,,,,,26000,12000,5000,4000,Heating,0.5 +90.1-2019,ASHRAE 169-2006-5C,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-5C,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 +90.1-2019,ASHRAE 169-2006-6A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-6A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-6A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 +90.1-2019,ASHRAE 169-2006-6A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-6A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-6A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2006-6B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-6B,TRUE,FALSE,,28000,26500,11000,5500,4500,3500,2500,1500,Heating,0.5 +90.1-2019,ASHRAE 169-2006-6B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-6B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2006-7A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-7A,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2019,ASHRAE 169-2006-7A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-7A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2006-7B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-7B,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2019,ASHRAE 169-2006-7B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-7B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2006-8A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-8A,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2019,ASHRAE 169-2006-8A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-8A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2006-8B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-8B,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2019,ASHRAE 169-2006-8B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2006-8B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2013-1A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-1A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-1A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-1A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-1B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-1B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-1B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-1B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-2A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-2A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-2A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-2A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-2B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-2B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-2B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-2B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-3A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-3A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-3A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 +90.1-2019,ASHRAE 169-2013-3A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-3A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-3A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5 +90.1-2019,ASHRAE 169-2013-3B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-3B,TRUE,FALSE,,,,,,,,,,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-3B,TRUE,FALSE,,,,,,,,,,Heating,0.5 +90.1-2019,ASHRAE 169-2013-3B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-3B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-3B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 +90.1-2019,ASHRAE 169-2013-3C,TRUE,TRUE,,,,,,,,,,, +90.1-2019,ASHRAE 169-2013-3C,TRUE,FALSE,,,,,,,,,,Heating,0.5 +90.1-2019,ASHRAE 169-2013-3C,FALSE,TRUE,,,,,,,,,,, +90.1-2019,ASHRAE 169-2013-3C,FALSE,FALSE,,,,,,,,,,Heating,0.5 +90.1-2019,ASHRAE 169-2013-4A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-4A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-4A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 +90.1-2019,ASHRAE 169-2013-4A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-4A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-4A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2013-4B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-4B,TRUE,FALSE,,,,,,,,,,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-4B,TRUE,FALSE,,,,,,,,,,Heating,0.5 +90.1-2019,ASHRAE 169-2013-4B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-4B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-4B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5 +90.1-2019,ASHRAE 169-2013-4C,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-4C,TRUE,FALSE,,,,,,,,,,Heating,0.5 +90.1-2019,ASHRAE 169-2013-4C,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-4C,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 +90.1-2019,ASHRAE 169-2013-5A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-5A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-5A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 +90.1-2019,ASHRAE 169-2013-5A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-5A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-5A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2013-5B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-5B,TRUE,FALSE,,,,,,,,,,Heating,0.5 +90.1-2019,ASHRAE 169-2013-5B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-5B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5 +90.1-2019,ASHRAE 169-2013-5C,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-5C,TRUE,FALSE,,,,,,26000,12000,5000,4000,Heating,0.5 +90.1-2019,ASHRAE 169-2013-5C,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-5C,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 +90.1-2019,ASHRAE 169-2013-6A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-6A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-6A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 +90.1-2019,ASHRAE 169-2013-6A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-6A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-6A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2013-6B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-6B,TRUE,FALSE,,28000,26500,11000,5500,4500,3500,2500,1500,Heating,0.5 +90.1-2019,ASHRAE 169-2013-6B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-6B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2013-7A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-7A,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2019,ASHRAE 169-2013-7A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-7A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2013-7B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-7B,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2019,ASHRAE 169-2013-7B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-7B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2013-8A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-8A,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2019,ASHRAE 169-2013-8A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-8A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2019,ASHRAE 169-2013-8B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-8B,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 +90.1-2019,ASHRAE 169-2013-8B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 +90.1-2019,ASHRAE 169-2013-8B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 +90.1-2010,ASHRAE 169-2006-0A,,,,,,5500,4500,3500,2000,1000,0,, +90.1-2010,ASHRAE 169-2006-0B,,,,,,,,26000,12000,5000,4000,, +90.1-2010,ASHRAE 169-2013-0A,,,,,,5500,4500,3500,2000,1000,0,, +90.1-2010,ASHRAE 169-2013-0B,,,,,,,,26000,12000,5000,4000,, +90.1-2013,ASHRAE 169-2006-0A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, +90.1-2013,ASHRAE 169-2006-0A,FALSE,,,2500,2000,1000,500,0,0,0,0,, +90.1-2013,ASHRAE 169-2006-0B,TRUE,,,,,,,26000,12000,5000,4000,, +90.1-2013,ASHRAE 169-2006-0B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, +90.1-2013,ASHRAE 169-2013-0A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, +90.1-2013,ASHRAE 169-2013-0A,FALSE,,,2500,2000,1000,500,0,0,0,0,, +90.1-2013,ASHRAE 169-2013-0B,TRUE,,,,,,,26000,12000,5000,4000,, +90.1-2013,ASHRAE 169-2013-0B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, +90.1-2016,ASHRAE 169-2006-0A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-0A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-0B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5 +90.1-2016,ASHRAE 169-2006-0B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-0A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-0A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-0B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5 +90.1-2016,ASHRAE 169-2013-0B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-0A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-0A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-0A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-0A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-0B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-0B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-0B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2006-0B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-0A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-0A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-0A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-0A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-0B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-0B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-0B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 +90.1-2019,ASHRAE 169-2013-0B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 diff --git a/data/openstudio_standards_data/database_tables/envelope_requirement.py b/data/openstudio_standards_data/database_tables/envelope_requirement.py index dc0396e54e..7efa926b14 100644 --- a/data/openstudio_standards_data/database_tables/envelope_requirement.py +++ b/data/openstudio_standards_data/database_tables/envelope_requirement.py @@ -97,7 +97,7 @@ def __init__(self): super(EnvelopeRequirementTable, self).__init__( table_name=TABLE_NAME, record_template=RECORD_TEMPLATE, - initial_data_directory=f"initial_data/{TABLE_NAME}", + initial_data_directory=f"database_files/{TABLE_NAME}", ) def get_record_info(self): diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_boilers_90_1.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_boilers_90_1.py index 28822f9b1a..d41134d160 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_boilers_90_1.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_boilers_90_1.py @@ -9,5 +9,5 @@ class HVACMinReqBoilers901Table(HVACMinReqBoilers): def __init__(self): super(HVACMinReqBoilers901Table, self).__init__( table_name=TABLE_NAME, - initial_data_directory=f"initial_data/{TABLE_NAME}", + initial_data_directory=f"database_files/{TABLE_NAME}", ) diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_chillers_90_1.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_chillers_90_1.py index 5486386771..8f0c448fe0 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_chillers_90_1.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_chillers_90_1.py @@ -11,5 +11,5 @@ class HVACMinimumRequirementChillers901Table(HVACMinimumRequirementChillers): def __init__(self): super(HVACMinimumRequirementChillers901Table, self).__init__( table_name=TABLE_NAME, - initial_data_directory=f"initial_data/{TABLE_NAME}", + initial_data_directory=f"database_files/{TABLE_NAME}", ) diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_furnaces_90_1.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_furnaces_90_1.py index 015857c025..d616d2f615 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_furnaces_90_1.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_furnaces_90_1.py @@ -11,5 +11,5 @@ class HVACMinimumRequirementFurnaces901Table(HVACMinimumRequirementFurnaces): def __init__(self): super(HVACMinimumRequirementFurnaces901Table, self).__init__( table_name=TABLE_NAME, - initial_data_directory=f"initial_data/{TABLE_NAME}", + initial_data_directory=f"database_files/{TABLE_NAME}", ) diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_cooling_90_1.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_cooling_90_1.py index 8709761d02..6aba91531b 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_cooling_90_1.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_cooling_90_1.py @@ -13,5 +13,5 @@ class HVACMinimumRequirementHeatPumpCooling901Table( def __init__(self): super(HVACMinimumRequirementHeatPumpCooling901Table, self).__init__( table_name=TABLE_NAME, - initial_data_directory=f"initial_data/{TABLE_NAME}", + initial_data_directory=f"database_files/{TABLE_NAME}", ) diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_heating_90_1.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_heating_90_1.py index 884002086b..675647cc64 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_heating_90_1.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_heating_90_1.py @@ -13,5 +13,5 @@ class HVACMinimumRequirementHeatPumpHeating901Table( def __init__(self): super(HVACMinimumRequirementHeatPumpHeating901Table, self).__init__( table_name=TABLE_NAME, - initial_data_directory=f"initial_data/{TABLE_NAME}", + initial_data_directory=f"database_files/{TABLE_NAME}", ) diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_rejection_90_1.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_rejection_90_1.py index 43a1563e96..1c9847fbd3 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_rejection_90_1.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_rejection_90_1.py @@ -11,5 +11,5 @@ class HVACMinimumRequirementHeatRejection901Table(HVACMinimumRequirementHeatReje def __init__(self): super(HVACMinimumRequirementHeatRejection901Table, self).__init__( table_name=TABLE_NAME, - initial_data_directory=f"initial_data/{TABLE_NAME}", + initial_data_directory=f"database_files/{TABLE_NAME}", ) diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_motors_90_1.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_motors_90_1.py index c083f45e4f..6d01fe1b6c 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_motors_90_1.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_motors_90_1.py @@ -9,5 +9,5 @@ class HVACMinimumRequirementMotors901Table(HVACMinimumRequirementMotors): def __init__(self): super(HVACMinimumRequirementMotors901Table, self).__init__( table_name=TABLE_NAME, - initial_data_directory=f"initial_data/{TABLE_NAME}", + initial_data_directory=f"database_files/{TABLE_NAME}", ) diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_unitary_air_conditioners_90_1.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_unitary_air_conditioners_90_1.py index 98372cfe00..f49dda53a4 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_unitary_air_conditioners_90_1.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_unitary_air_conditioners_90_1.py @@ -13,5 +13,5 @@ class HVACMinimumRequirementUnitaryAirConditioners901Table( def __init__(self): super(HVACMinimumRequirementUnitaryAirConditioners901Table, self).__init__( table_name=TABLE_NAME, - initial_data_directory=f"initial_data/{TABLE_NAME}", + initial_data_directory=f"database_files/{TABLE_NAME}", ) diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_heaters_90_1.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_heaters_90_1.py index 5999f58e3a..d52e23e88e 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_heaters_90_1.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_heaters_90_1.py @@ -11,5 +11,5 @@ class HVACMinimumRequirementWaterHeaters901Table(HVACMinimumRequirementWaterHeat def __init__(self): super(HVACMinimumRequirementWaterHeaters901Table, self).__init__( table_name=TABLE_NAME, - initial_data_directory=f"initial_data/{TABLE_NAME}", + initial_data_directory=f"database_files/{TABLE_NAME}", ) diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1.py index b923fc7008..d765108e55 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1.py @@ -13,5 +13,5 @@ class HVACMinimumRequirementWaterSourceHeatPumpsCooling901Table( def __init__(self): super(HVACMinimumRequirementWaterSourceHeatPumpsCooling901Table, self).__init__( table_name=TABLE_NAME, - initial_data_directory=f"initial_data/{TABLE_NAME}", + initial_data_directory=f"database_files/{TABLE_NAME}", ) diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_heating_90_1.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_heating_90_1.py index 6d57f5a53e..ae29fecf06 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_heating_90_1.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_heating_90_1.py @@ -13,5 +13,5 @@ class HVACMinimumRequirementWaterSourceHeatPumpsHeating901Table( def __init__(self): super(HVACMinimumRequirementWaterSourceHeatPumpsHeating901Table, self).__init__( table_name=TABLE_NAME, - initial_data_directory=f"initial_data/{TABLE_NAME}", + initial_data_directory=f"database_files/{TABLE_NAME}", ) diff --git a/data/openstudio_standards_data/database_tables/level_1_space_types.py b/data/openstudio_standards_data/database_tables/level_1_space_types.py index 823fa642e4..cd801e415f 100644 --- a/data/openstudio_standards_data/database_tables/level_1_space_types.py +++ b/data/openstudio_standards_data/database_tables/level_1_space_types.py @@ -44,7 +44,7 @@ def __init__(self): super(GeneralBuildingSpaceTypeTable, self).__init__( table_name=TABLE_NAME, record_template=RECORD_TEMPLATE, - initial_data_directory=f"initial_data/{TABLE_NAME}", + initial_data_directory=f"database_files/{TABLE_NAME}", ) def get_record_info(self): diff --git a/data/openstudio_standards_data/database_tables/level_2_electric_equipment.py b/data/openstudio_standards_data/database_tables/level_2_electric_equipment.py index c753772976..80e382702b 100644 --- a/data/openstudio_standards_data/database_tables/level_2_electric_equipment.py +++ b/data/openstudio_standards_data/database_tables/level_2_electric_equipment.py @@ -48,7 +48,7 @@ def __init__(self): super(EquipLoadTable, self).__init__( table_name=TABLE_NAME, record_template=RECORD_TEMPLATE, - initial_data_directory=f"initial_data/{TABLE_NAME}", + initial_data_directory=f"database_files/{TABLE_NAME}", ) def get_record_info(self): diff --git a/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py b/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py index 1e0fd87447..6b2932d3e4 100644 --- a/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py +++ b/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py @@ -38,7 +38,7 @@ def __init__(self): super(LightSubspaceTable, self).__init__( table_name=TABLE_NAME, record_template=RECORD_TEMPLATE, - initial_data_directory=f"initial_data/{TABLE_NAME}", + initial_data_directory=f"database_files/{TABLE_NAME}", ) def get_record_info(self): diff --git a/data/openstudio_standards_data/database_tables/level_2_ventilation_space_types.py b/data/openstudio_standards_data/database_tables/level_2_ventilation_space_types.py index 0800386f72..622e78aca5 100644 --- a/data/openstudio_standards_data/database_tables/level_2_ventilation_space_types.py +++ b/data/openstudio_standards_data/database_tables/level_2_ventilation_space_types.py @@ -39,7 +39,7 @@ def __init__(self): super(VentSubspaceTable, self).__init__( table_name=TABLE_NAME, record_template=RECORD_TEMPLATE, - initial_data_directory=f"initial_data/{TABLE_NAME}", + initial_data_directory=f"database_files/{TABLE_NAME}", ) def get_record_info(self): diff --git a/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2004.py b/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2004.py index 22d45856a3..09ce53cf42 100644 --- a/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2004.py +++ b/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2004.py @@ -9,5 +9,5 @@ class LightDef9012004Table(LightDef901): def __init__(self): super(LightDef9012004Table, self).__init__( table_name=TABLE_NAME, - initial_data_directory=f"initial_data/{TABLE_NAME}", + initial_data_directory=f"database_files/{TABLE_NAME}", ) diff --git a/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2019.py b/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2019.py index 2e3e5605d7..8f11268de5 100644 --- a/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2019.py +++ b/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2019.py @@ -8,5 +8,5 @@ class LightDef9012019Table(LightDef901): def __init__(self): super(LightDef9012019Table, self).__init__( - table_name=TABLE_NAME, initial_data_directory=f"initial_data/{TABLE_NAME}" + table_name=TABLE_NAME, initial_data_directory=f"database_files/{TABLE_NAME}" ) diff --git a/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2004.py b/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2004.py index d79e3fa6b4..6ab136d49a 100644 --- a/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2004.py +++ b/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2004.py @@ -9,5 +9,5 @@ class VentDef6212004Table(VentDef621): def __init__(self): super(VentDef6212004Table, self).__init__( table_name=TABLE_NAME, - initial_data_directory=f"initial_data/{TABLE_NAME}", + initial_data_directory=f"database_files/{TABLE_NAME}", ) diff --git a/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2019.py b/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2019.py index 3845d46a07..4a53fef6e0 100644 --- a/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2019.py +++ b/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2019.py @@ -8,5 +8,5 @@ class VentDef6212019Table(VentDef621): def __init__(self): super(VentDef6212019Table, self).__init__( - table_name=TABLE_NAME, initial_data_directory=f"initial_data/{TABLE_NAME}" + table_name=TABLE_NAME, initial_data_directory=f"database_files/{TABLE_NAME}" ) diff --git a/data/openstudio_standards_data/database_tables/support_constructions.py b/data/openstudio_standards_data/database_tables/support_constructions.py index 0dc2d53d18..b5600923b6 100644 --- a/data/openstudio_standards_data/database_tables/support_constructions.py +++ b/data/openstudio_standards_data/database_tables/support_constructions.py @@ -77,7 +77,7 @@ def __init__(self): super(SupportConstructionsTable, self).__init__( table_name=TABLE_NAME, record_template=RECORD_TEMPLATE, - initial_data_directory=f"initial_data/{TABLE_NAME}", + initial_data_directory=f"database_files/{TABLE_NAME}", ) def get_record_info(self): diff --git a/data/openstudio_standards_data/database_tables/support_electric_equipment_space_type_name_tags.py b/data/openstudio_standards_data/database_tables/support_electric_equipment_space_type_name_tags.py index c2c4659fe2..e3a3d3cf9a 100644 --- a/data/openstudio_standards_data/database_tables/support_electric_equipment_space_type_name_tags.py +++ b/data/openstudio_standards_data/database_tables/support_electric_equipment_space_type_name_tags.py @@ -32,7 +32,7 @@ def __init__(self): super(PlugLoadSpaceTagTable, self).__init__( table_name=TABLE_NAME, record_template=RECORD_TEMPLATE, - initial_data_directory=f"initial_data/{TABLE_NAME}", + initial_data_directory=f"database_files/{TABLE_NAME}", ) def get_record_info(self): diff --git a/data/openstudio_standards_data/database_tables/support_lighting_space_type_name_tags.py b/data/openstudio_standards_data/database_tables/support_lighting_space_type_name_tags.py index 0080e390be..2ff6a57036 100644 --- a/data/openstudio_standards_data/database_tables/support_lighting_space_type_name_tags.py +++ b/data/openstudio_standards_data/database_tables/support_lighting_space_type_name_tags.py @@ -32,7 +32,7 @@ def __init__(self): super(LightingSpaceTagTable, self).__init__( table_name=TABLE_NAME, record_template=RECORD_TEMPLATE, - initial_data_directory=f"initial_data/{TABLE_NAME}", + initial_data_directory=f"database_files/{TABLE_NAME}", ) def get_record_info(self): diff --git a/data/openstudio_standards_data/database_tables/support_materials.py b/data/openstudio_standards_data/database_tables/support_materials.py index ac4638b078..ae0bceba5d 100644 --- a/data/openstudio_standards_data/database_tables/support_materials.py +++ b/data/openstudio_standards_data/database_tables/support_materials.py @@ -143,7 +143,7 @@ def __init__(self): super(SupportMaterialTable, self).__init__( table_name=TABLE_NAME, record_template=RECORD_TEMPLATE, - initial_data_directory=f"initial_data/{TABLE_NAME}", + initial_data_directory=f"database_files/{TABLE_NAME}", ) def get_record_info(self): diff --git a/data/openstudio_standards_data/database_tables/support_performance_curves.py b/data/openstudio_standards_data/database_tables/support_performance_curves.py index 943a636d87..d9fcfceaa3 100644 --- a/data/openstudio_standards_data/database_tables/support_performance_curves.py +++ b/data/openstudio_standards_data/database_tables/support_performance_curves.py @@ -123,7 +123,7 @@ def __init__(self): super(VentSpaceTagTable, self).__init__( table_name=TABLE_NAME, record_template=RECORD_TEMPLATE, - initial_data_directory=f"initial_data/{TABLE_NAME}", + initial_data_directory=f"database_files/{TABLE_NAME}", ) def get_record_info(self): diff --git a/data/openstudio_standards_data/database_tables/support_standard_templates.py b/data/openstudio_standards_data/database_tables/support_standard_templates.py index 62cccfdfcd..5852016c5a 100644 --- a/data/openstudio_standards_data/database_tables/support_standard_templates.py +++ b/data/openstudio_standards_data/database_tables/support_standard_templates.py @@ -42,7 +42,7 @@ def __init__(self): super(StandardTemplateTable, self).__init__( table_name=TABLE_NAME, record_template=RECORD_TEMPLATE, - initial_data_directory=f"initial_data/{TABLE_NAME}", + initial_data_directory=f"database_files/{TABLE_NAME}", ) def get_record_info(self): diff --git a/data/openstudio_standards_data/database_tables/support_ventilation_space_type_name_tags.py b/data/openstudio_standards_data/database_tables/support_ventilation_space_type_name_tags.py index 7bdd2d78f8..0f03ed99d6 100644 --- a/data/openstudio_standards_data/database_tables/support_ventilation_space_type_name_tags.py +++ b/data/openstudio_standards_data/database_tables/support_ventilation_space_type_name_tags.py @@ -32,7 +32,7 @@ def __init__(self): super(VentSpaceTagTable, self).__init__( table_name=TABLE_NAME, record_template=RECORD_TEMPLATE, - initial_data_directory=f"initial_data/{TABLE_NAME}", + initial_data_directory=f"database_files/{TABLE_NAME}", ) def get_record_info(self): diff --git a/data/openstudio_standards_data/database_tables/system_requirement_economizer_90_1.py b/data/openstudio_standards_data/database_tables/system_requirement_economizer_90_1.py index d2b83fd96a..2c1ec43a4a 100644 --- a/data/openstudio_standards_data/database_tables/system_requirement_economizer_90_1.py +++ b/data/openstudio_standards_data/database_tables/system_requirement_economizer_90_1.py @@ -9,5 +9,5 @@ class SystemRequirementEconomizer901Table(SystemRequirementEconomizer): def __init__(self): super(SystemRequirementEconomizer901Table, self).__init__( table_name=TABLE_NAME, - initial_data_directory=f"initial_data/{TABLE_NAME}", + initial_data_directory=f"database_files/{TABLE_NAME}", ) diff --git a/data/openstudio_standards_data/database_tables/system_requirement_energy_recovery_90_1.py b/data/openstudio_standards_data/database_tables/system_requirement_energy_recovery_90_1.py index c3af6f5ca4..8075cce4fa 100644 --- a/data/openstudio_standards_data/database_tables/system_requirement_energy_recovery_90_1.py +++ b/data/openstudio_standards_data/database_tables/system_requirement_energy_recovery_90_1.py @@ -11,5 +11,5 @@ class SystemRequirementEnergyRecovery901Table(SystemRequirementEnergyRecovery): def __init__(self): super(SystemRequirementEnergyRecovery901Table, self).__init__( table_name=TABLE_NAME, - initial_data_directory=f"initial_data/{TABLE_NAME}", + initial_data_directory=f"database_files/{TABLE_NAME}", ) From 0dc457348134144973c8f1185bac2c813c36081e Mon Sep 17 00:00:00 2001 From: Jeremy L <5149279+lymereJ@users.noreply.github.com> Date: Thu, 23 Mar 2023 22:41:49 -0700 Subject: [PATCH 06/45] Remove IDs from export, fix typos (#1465) * Remove IDs from export, fix typos. * Same change but for JSON export. * Fix typos. * Fix typo. * Missing comma * Missing annotation column. * Float formatting * Temporary add JSON files. * Remove initial data folder. * Catch conversion CSV to JSON and JSON to CSV issues. --- .../database_engine/database.py | 15 +- .../database_engine/database_util.py | 7 +- .../database_files/envelope_requirement.csv | 2 +- .../database_files/envelope_requirement.json | 86129 ++++++++++++++++ ...hvac_minimum_requirement_boilers_90_1.json | 338 + ...vac_minimum_requirement_chillers_90_1.json | 2918 + ...vac_minimum_requirement_furnaces_90_1.json | 134 + ...um_requirement_heat_pump_cooling_90_1.json | 3610 + ...um_requirement_heat_pump_heating_90_1.json | 1002 + ...nimum_requirement_heat_rejection_90_1.json | 272 + .../hvac_minimum_requirement_motors_90_1.json | 1472 + ...irement_unitary_air_conditioners_90_1.json | 4487 + ...inimum_requirement_water_heaters_90_1.json | 410 + ..._water_source_heat_pumps_cooling_90_1.json | 164 + ..._water_source_heat_pumps_heating_90_1.json | 56 + .../database_files/level_1_space_types.json | 770 + .../level_2_electric_equipment.json | 722 + .../level_2_lighting_space_types.json | 1432 + .../level_2_ventilation_space_types.json | 867 + .../level_3_lighting_90_1_2004.json} | 151 +- .../level_3_lighting_90_1_2019.json} | 164 +- .../level_3_ventilation_62_1_2004.csv | 128 +- .../level_3_ventilation_62_1_2004.json} | 65 +- .../level_3_ventilation_62_1_2019.csv | 220 +- .../level_3_ventilation_62_1_2019.json} | 113 +- .../database_files/support_constructions.csv | 2 +- .../database_files/support_constructions.json | 6385 ++ ...ectric_equipment_space_type_name_tags.json | 464 + ...support_lighting_space_type_name_tags.json | 476 + .../database_files/support_materials.csv | 4 +- .../database_files/support_materials.json | 43061 ++++++++ .../support_performance_curves.csv | 358 +- .../support_performance_curves.json | 18327 ++++ .../support_standard_templates.json | 16 + ...port_ventilation_space_type_name_tags.json | 332 + .../system_requirement_economizer_90_1.json | 3970 + ...ystem_requirement_energy_recovery_90_1.csv | 816 +- ...stem_requirement_energy_recovery_90_1.json | 7346 ++ .../database_tables/envelope_requirement.py | 12 +- .../database_tables/support_constructions.py | 12 +- .../initial_data/envelope_requirement.csv | 4534 - .../general_building_space_type.json | 898 - .../general_building_space_type_full.csv | 221 - .../hvac_minimum_requirement_boilers_90_1.csv | 22 - ...hvac_minimum_requirement_chillers_90_1.csv | 163 - ...hvac_minimum_requirement_furnaces_90_1.csv | 13 - ...mum_requirement_heat_pump_cooling_90_1.csv | 165 - ...mum_requirement_heat_pump_heating_90_1.csv | 51 - ...inimum_requirement_heat_rejection_90_1.csv | 31 - .../hvac_minimum_requirement_motors_90_1.csv | 148 - ...uirement_unitary_air_conditioners_90_1.csv | 196 - ...minimum_requirement_water_heaters_90_1.csv | 25 - ...t_water_source_heat_pumps_cooling_90_1.csv | 19 - ...t_water_source_heat_pumps_heating_90_1.csv | 7 - .../initial_data/level_1_space_types.csv | 129 - .../level_2_electric_equipment.csv | 91 - .../level_2_lighting_space_types.csv | 287 - .../level_2_ventilation_space_types.csv | 174 - .../level_3_lighting_90_1_2004.csv | 126 - .../level_3_lighting_90_1_2019.csv | 139 - .../level_3_ventilation_62_1_2004.csv | 64 - .../level_3_ventilation_62_1_2019.csv | 110 - .../initial_data/light_subspaces.json | 1718 - .../initial_data/lighting_space_tag.json | 476 - .../initial_data/plug_load_space_tag.json | 464 - .../initial_data/standard_template.json | 18 - .../initial_data/support_constructions.csv | 492 - ...lectric_equipment_space_type_name_tags.csv | 155 - .../support_lighting_space_type_name_tags.csv | 159 - .../initial_data/support_materials.csv | 1390 - .../support_performance_curves.csv | 734 - .../support_standard_templates.csv | 3 - ...pport_ventilation_space_type_name_tags.csv | 111 - .../system_requirement_economizer_90_1.csv | 497 - ...ystem_requirement_energy_recovery_90_1.csv | 409 - .../initial_data/vent_space_tag.json | 332 - .../initial_data/vent_subspaces.json | 1040 - 77 files changed, 185983 insertions(+), 16857 deletions(-) create mode 100644 data/openstudio_standards_data/database_files/envelope_requirement.json create mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_boilers_90_1.json create mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_chillers_90_1.json create mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_furnaces_90_1.json create mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_pump_cooling_90_1.json create mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_pump_heating_90_1.json create mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_rejection_90_1.json create mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_motors_90_1.json create mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_unitary_air_conditioners_90_1.json create mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_heaters_90_1.json create mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1.json create mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_source_heat_pumps_heating_90_1.json create mode 100644 data/openstudio_standards_data/database_files/level_1_space_types.json create mode 100644 data/openstudio_standards_data/database_files/level_2_electric_equipment.json create mode 100644 data/openstudio_standards_data/database_files/level_2_lighting_space_types.json create mode 100644 data/openstudio_standards_data/database_files/level_2_ventilation_space_types.json rename data/openstudio_standards_data/{initial_data/light_def_90_1_2004.json => database_files/level_3_lighting_90_1_2004.json} (90%) rename data/openstudio_standards_data/{initial_data/light_def_90_1_2019.json => database_files/level_3_lighting_90_1_2019.json} (91%) rename data/openstudio_standards_data/{initial_data/vent_def_62_1_2004.json => database_files/level_3_ventilation_62_1_2004.json} (96%) rename data/openstudio_standards_data/{initial_data/vent_def_62_1_2019.json => database_files/level_3_ventilation_62_1_2019.json} (96%) create mode 100644 data/openstudio_standards_data/database_files/support_constructions.json create mode 100644 data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.json create mode 100644 data/openstudio_standards_data/database_files/support_lighting_space_type_name_tags.json create mode 100644 data/openstudio_standards_data/database_files/support_materials.json create mode 100644 data/openstudio_standards_data/database_files/support_performance_curves.json create mode 100644 data/openstudio_standards_data/database_files/support_standard_templates.json create mode 100644 data/openstudio_standards_data/database_files/support_ventilation_space_type_name_tags.json create mode 100644 data/openstudio_standards_data/database_files/system_requirement_economizer_90_1.json create mode 100644 data/openstudio_standards_data/database_files/system_requirement_energy_recovery_90_1.json delete mode 100644 data/openstudio_standards_data/initial_data/envelope_requirement.csv delete mode 100644 data/openstudio_standards_data/initial_data/general_building_space_type.json delete mode 100644 data/openstudio_standards_data/initial_data/general_building_space_type_full.csv delete mode 100644 data/openstudio_standards_data/initial_data/hvac_minimum_requirement_boilers_90_1.csv delete mode 100644 data/openstudio_standards_data/initial_data/hvac_minimum_requirement_chillers_90_1.csv delete mode 100644 data/openstudio_standards_data/initial_data/hvac_minimum_requirement_furnaces_90_1.csv delete mode 100644 data/openstudio_standards_data/initial_data/hvac_minimum_requirement_heat_pump_cooling_90_1.csv delete mode 100644 data/openstudio_standards_data/initial_data/hvac_minimum_requirement_heat_pump_heating_90_1.csv delete mode 100644 data/openstudio_standards_data/initial_data/hvac_minimum_requirement_heat_rejection_90_1.csv delete mode 100644 data/openstudio_standards_data/initial_data/hvac_minimum_requirement_motors_90_1.csv delete mode 100644 data/openstudio_standards_data/initial_data/hvac_minimum_requirement_unitary_air_conditioners_90_1.csv delete mode 100644 data/openstudio_standards_data/initial_data/hvac_minimum_requirement_water_heaters_90_1.csv delete mode 100644 data/openstudio_standards_data/initial_data/hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1.csv delete mode 100644 data/openstudio_standards_data/initial_data/hvac_minimum_requirement_water_source_heat_pumps_heating_90_1.csv delete mode 100644 data/openstudio_standards_data/initial_data/level_1_space_types.csv delete mode 100644 data/openstudio_standards_data/initial_data/level_2_electric_equipment.csv delete mode 100644 data/openstudio_standards_data/initial_data/level_2_lighting_space_types.csv delete mode 100644 data/openstudio_standards_data/initial_data/level_2_ventilation_space_types.csv delete mode 100644 data/openstudio_standards_data/initial_data/level_3_lighting_90_1_2004.csv delete mode 100644 data/openstudio_standards_data/initial_data/level_3_lighting_90_1_2019.csv delete mode 100644 data/openstudio_standards_data/initial_data/level_3_ventilation_62_1_2004.csv delete mode 100644 data/openstudio_standards_data/initial_data/level_3_ventilation_62_1_2019.csv delete mode 100644 data/openstudio_standards_data/initial_data/light_subspaces.json delete mode 100644 data/openstudio_standards_data/initial_data/lighting_space_tag.json delete mode 100644 data/openstudio_standards_data/initial_data/plug_load_space_tag.json delete mode 100644 data/openstudio_standards_data/initial_data/standard_template.json delete mode 100644 data/openstudio_standards_data/initial_data/support_constructions.csv delete mode 100644 data/openstudio_standards_data/initial_data/support_electric_equipment_space_type_name_tags.csv delete mode 100644 data/openstudio_standards_data/initial_data/support_lighting_space_type_name_tags.csv delete mode 100644 data/openstudio_standards_data/initial_data/support_materials.csv delete mode 100644 data/openstudio_standards_data/initial_data/support_performance_curves.csv delete mode 100644 data/openstudio_standards_data/initial_data/support_standard_templates.csv delete mode 100644 data/openstudio_standards_data/initial_data/support_ventilation_space_type_name_tags.csv delete mode 100644 data/openstudio_standards_data/initial_data/system_requirement_economizer_90_1.csv delete mode 100644 data/openstudio_standards_data/initial_data/system_requirement_energy_recovery_90_1.csv delete mode 100644 data/openstudio_standards_data/initial_data/vent_space_tag.json delete mode 100644 data/openstudio_standards_data/initial_data/vent_subspaces.json diff --git a/data/openstudio_standards_data/database_engine/database.py b/data/openstudio_standards_data/database_engine/database.py index 2999599f82..8202ed254f 100644 --- a/data/openstudio_standards_data/database_engine/database.py +++ b/data/openstudio_standards_data/database_engine/database.py @@ -105,8 +105,12 @@ def export_table_to_csv(self, conn, save_dir=""): csv_dir = f"{save_dir}{self.data_table_name}.csv" with open(csv_dir, "w", newline="") as csv_file: csv_writer = csv.writer(csv_file, delimiter=",") - csv_writer.writerow([i[0] for i in cursor.description]) - csv_writer.writerows(cursor) + csv_writer.writerow([i[0] for i in cursor.description if i[0] != "id"]) + rows = [] + # Exclude IDs + exclude_first_row = True if cursor.description[0][0] == "id" else False + rows = [i[1:] for i in cursor] if exclude_first_row else cursor + csv_writer.writerows(rows) def export_table_to_json(self, conn, save_dir=""): """ @@ -122,10 +126,13 @@ def export_table_to_json(self, conn, save_dir=""): dict((cursor.description[i][0], value) for i, value in enumerate(row)) for row in cursor.fetchall() ] - + # Exclude IDs + for i in r: + if "id" in i.keys(): + del i["id"] json_dir = f"{save_dir}{self.data_table_name}.json" json_output = json.dumps(r, indent=4) - with open(json_dir, "w", newline="") as json_file: + with open(json_dir, "w", newline="\r\n") as json_file: json_file.write(json_output) def _preprocess_record(self, record): diff --git a/data/openstudio_standards_data/database_engine/database_util.py b/data/openstudio_standards_data/database_engine/database_util.py index a04fff3e4a..756271f2fe 100644 --- a/data/openstudio_standards_data/database_engine/database_util.py +++ b/data/openstudio_standards_data/database_engine/database_util.py @@ -70,4 +70,9 @@ def getattr_either(key: str, record: dict, option=None): :param option: value return when reject (optional), default is None :return: value """ - return record[key] if record.get(key) else option + if record.get(key) == "": # used for reading data from CSV + return option + elif record.get(key) is None: # used for readting data from CSV + return option + else: + return f"{record[key]}" diff --git a/data/openstudio_standards_data/database_files/envelope_requirement.csv b/data/openstudio_standards_data/database_files/envelope_requirement.csv index 19467ee5b2..02c51b2614 100644 --- a/data/openstudio_standards_data/database_files/envelope_requirement.csv +++ b/data/openstudio_standards_data/database_files/envelope_requirement.csv @@ -1,4 +1,4 @@ -template,climate_zone_set,intended_surface_type,standards_construction_type,building_category,construction,orientation,minimum_percent_of_surface,maximum_percent_of_surface,assembly_maximum_u_value,u_value_includes_interior_film_coefficient,u_value_includes_exterior_film_coefficient,asssembly_maximum_f_factor,assembly_maximum_c_factor,assembly_maximum_solar_heat_gain_coefficient,assembly_minimum_vt_shgc,annotation +template,climate_zone_set,intended_surface_type,standards_construction_type,building_category,construction,orientation,minimum_percent_of_surface,maximum_percent_of_surface,assembly_maximum_u_value,u_value_includes_interior_film_coefficient,u_value_includes_exterior_film_coefficient,assembly_maximum_f_factor,assembly_maximum_c_factor,assembly_maximum_solar_heat_gain_coefficient,assembly_minimum_vt_shgc,annotation 90.1-2004,ClimateZone 1,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, 90.1-2004,ClimateZone 1,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, 90.1-2004,ClimateZone 1,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, diff --git a/data/openstudio_standards_data/database_files/envelope_requirement.json b/data/openstudio_standards_data/database_files/envelope_requirement.json new file mode 100644 index 0000000000..383b01982e --- /dev/null +++ b/data/openstudio_standards_data/database_files/envelope_requirement.json @@ -0,0 +1,86129 @@ +[ + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.034, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.614, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.28, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.18, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.352, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.292, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.137, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.107, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.034, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.218, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.081, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.167, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.184, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.352, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.292, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.17 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.17, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.17 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.17, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.17 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.17, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.17 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.17, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.17 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.17, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.17 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.17, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.17 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.17, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.17 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.17, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 1.98 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 1.98 SHGC 0.19 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.98 SHGC 0.19 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 1.90 SHGC 0.34 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 1.90 SHGC 0.27 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 1.36 SHGC 0.19 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.107, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.087, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.069, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.034, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.218, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.081, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.097, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.123, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.084, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.184, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.352, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 1.17 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.17, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 1.17 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.17, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.98 SHGC 0.34 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.34, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 1.30 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.3, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.27, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 1.30 SHGC 0.27 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.3, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.27, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.69 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.69, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.69 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.69, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3A", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.107, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.087, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.069, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.218, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.081, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.097, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.123, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.084, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.184, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.352, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.034, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 1.17 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.17, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 1.17 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.17, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.98 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 1.30 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.3, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 1.30 SHGC 0.27 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.3, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.69 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.69, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.69 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.69, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3B", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.65, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.107, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.087, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.069, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.218, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.081, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.097, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.123, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.084, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.184, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.352, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.61 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.61, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.61 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.61, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.61 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.61, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.34 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.34, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.34 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.34, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.34 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.34, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.61 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.61, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.61 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.61, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.61 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.61, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.61 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.61, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.61 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.61, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.61 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.61, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.34 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.34, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.34 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.34, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.34 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.34, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.72 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.72, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.72 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.72, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.72 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.72, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.61 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.61, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.34 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.34, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.61 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.61, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.61 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.61, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.34 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.34, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.72 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.72, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.034, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 1.98 SHGC 0.61 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.27, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 1.98 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.27, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.98 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 1.90 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 1.90 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 1.36 SHGC 0.61 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 1.36 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 3C", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.107, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.087, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.069, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.066, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.034, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.218, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.081, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.097, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.104, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.134, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.95, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.84, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 1.17 SHGC 0.49 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.17, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.98 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.98 SHGC 0.19 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 1.30 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.3, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 1.30 SHGC 0.62 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.3, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.65, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.69 SHGC 0.49 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.69, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.27, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.58 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.27, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.087, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.074, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.069, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.066, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.034, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.173, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.053, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.097, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.123, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.084, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.09, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.057, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.123, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.26 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.26, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.26 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.26, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.26 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.26, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.26 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.26, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.26 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.26, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.26 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.26, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.26 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.26, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.26 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.26, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.84, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.84, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 1.17 SHGC 0.49 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.17, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 1.17 SHGC 0.49 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.17, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.98 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 1.10 SHGC 0.77 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.1, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 1.10 SHGC 0.77 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.1, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.69 SHGC 0.49 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.69, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.61, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.69 SHGC 0.49 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.69, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.087, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.069, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.0066, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.173, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.053, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.097, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.104, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.084, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.09, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.057, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.26 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.26, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.26 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.26, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.26 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.26, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.26 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.26, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.26 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.26, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.26 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.26, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.26 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.26, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.39 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.26 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.26, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.84, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.78, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 1.17 SHGC 0.49 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.17, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.98 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.65, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.87 SHGC 0.71 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.87, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.65, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.74 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.74, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.34, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.69 SHGC 0.49 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.69, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.58 SHGC 0.61 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.61, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.087, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.137, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.066, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.173, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.053, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.097, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.09, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.057, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.08, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.057, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.49 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.84, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.54, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.78, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 1.17 SHGC 0.68 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.17, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 1.17 SHGC 0.64 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.17, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.98 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.87 SHGC 0.77 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.87, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.61 SHGC 0.77 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.61, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.69 SHGC 0.68 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.69, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.69 SHGC 0.64 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.69, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.65, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.057, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.137, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.049, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.049, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.093, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.034, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.072, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.08, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.057, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.071, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.057, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.055, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.35 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.35 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.35 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.35 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.35 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.35 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.35 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.46 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 0.46, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.35 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.54, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.78, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.52, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.78, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.95, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.98 SHGC 0.62 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.62, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.98 SHGC 0.27 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.27, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.30 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.3, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.61 SHGC 0.77 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.61, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.61 SHGC 0.77 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.61, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.10 SHGC 0.77 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.1, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.58 SHGC 0.19 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.58 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 0.81 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.81, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 1.98 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 1.98 SHGC 0.19 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.98 SHGC 0.16 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.16, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 1.90 SHGC 0.34 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 1.90 SHGC 0.27 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.34, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.27, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 1.36 SHGC 0.19 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.27, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.034, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.218, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.081, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.28, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.107, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.087, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.069, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.066, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.218, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.081, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.167, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.123, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.184, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.75 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.7 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.75 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.75 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.7 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.75 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 1.1 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.1, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 1.1 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.1, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 1.98 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 1.98 SHGC 0.19 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.98 SHGC 0.49 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 1.90 SHGC 0.27 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 1.36 SHGC 0.19 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.46, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.107, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.087, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.069, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.066, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.173, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.053, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.055, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.097, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.123, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.084, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.104, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.084, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.184, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.65 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.6 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.6, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.65 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.65 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.6 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.6, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.65 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.9 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.9 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.9, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.09, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 1.17 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.17, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 1.17 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.17, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.98 SHGC 0.71 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.71, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 1.30 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.3, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.65, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 1.30 SHGC 0.27 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.3, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.55, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.69 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.69, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.69 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.69, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.087, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.074, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.137, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.069, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.066, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.173, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.053, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.097, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.104, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.09, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.134, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.4 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.4, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.55 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.4 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.4, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.55 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.85 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.85, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.85 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.85, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.86, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.54, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.86, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 1.17 SHGC 0.49 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.17, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.98 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.98 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 1.30 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.3, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.68, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 1.30 SHGC 0.62 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.3, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.64, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.64, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.69 SHGC 0.49 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.69, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.58 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.77, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.074, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.137, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.119, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.053, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.097, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.09, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.08, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.057, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.123, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.35 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.45 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.55 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.35 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.45 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.55 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.8 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.8 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.86, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.54, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.86, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 1.17 SHGC 0.49 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.17, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.77, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 1.17 SHGC 0.49 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.17, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.77, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.98 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 1.10 SHGC 0.77 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.1, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 1.10 SHGC 0.77 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.1, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.68, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.64, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.69 SHGC 0.49 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.69, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.64, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.69 SHGC 0.49 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.69, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.057, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.137, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.093, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.034, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.097, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.08, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.071, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.057, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.35 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.45 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.55 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.35 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.45 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.55 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.65 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.6 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.6, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.65 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.8 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.8 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.9 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.54, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.86, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.52, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.688, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 1.17 SHGC 0.49 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.17, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.98 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.87 SHGC 0.71 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.87, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.74 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.74, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.69 SHGC 0.49 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.69, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.58 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.107, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.093, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.034, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.097, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.071, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.057, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.071, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.057, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.042, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.123, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.35 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.4 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.4, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.45 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.35 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.4 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.4, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.45 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.65 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.6 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.6, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.65 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.8 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.8 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.9 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.52, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.843, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.52, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.688, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.9, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.092, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 1.17 SHGC 0.68 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.17, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 1.17 SHGC 0.64 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.17, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.98 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.87 SHGC 0.77 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.87, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.61 SHGC 0.77 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.61, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.69 SHGC 0.68 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.69, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.69 SHGC 0.64 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.69, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.16, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.057, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.087, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.049, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.049, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.021, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.021, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.034, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.072, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.071, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.057, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.036, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.057, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.037, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.036, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.104, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.084, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.35 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.4 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.4, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.45 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.35 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.4 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.4, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.45 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.65 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.6 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.6, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.65 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.8 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.8 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.9 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.52, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.688, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.51, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.688, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.9, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.075, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.30 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.3, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.34, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.61 SHGC 0.77 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.61, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.27, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.61 SHGC 0.77 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.61, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.27, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.10 SHGC 0.77 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.1, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.58 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.58 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 0.81 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.81, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.18, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.352, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.292, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 1.98 SHGC 0.49 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 1.98 SHGC 0.19 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.98 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 1.90 SHGC 0.34 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 1.90 SHGC 0.27 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.77, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.77, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 1.36 SHGC 0.19 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.62, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Uninsulated Swinging Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.034, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.218, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.081, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.167, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.093, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Uninsulated Swinging Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.107, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.087, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.069, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.066, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.081, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.218, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.055, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.055, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.097, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.123, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.093, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.093, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.75 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.75 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.7 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.7 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.75 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.75 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 1.1 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.1, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 1.1 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.1, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "ext-slab", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 1.98 SHGC 0.27 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.27, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 1.98 SHGC 0.19 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.27, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.98 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 1.90 SHGC 0.27 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 1.36 SHGC 0.19 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Uninsulated Swinging Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.107, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.087, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.069, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.066, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.055, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.055, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.173, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.053, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.097, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.123, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.084, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.084, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.104, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.084, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.65 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.6 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.6, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.65 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.65 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.6 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.6, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.65 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.9 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.9 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Smallhotel 2010 Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Smallhotel 2010 Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.9, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Smallhotel 2010 Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Smallhotel 2010 Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.09, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "ext-slab", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 1.17 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.17, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 1.17 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.17, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.98 SHGC 0.19 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 1.30 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.3, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 1.30 SHGC 0.27 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.3, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.65, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.69 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.69, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.27, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.69 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.69, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.27, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Uninsulated Swinging Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.087, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.074, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.137, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.069, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.066, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.055, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.055, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.173, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.053, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.097, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.104, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.084, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.09, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.084, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.4 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.4, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.55 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.4 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.4, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.55 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.85 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.85, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.85 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.85, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.86, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.54, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.86, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "ext-slab", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 1.17 SHGC 0.49 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.17, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.98 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.98 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 1.30 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.3, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 1.30 SHGC 0.62 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.3, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.69 SHGC 0.49 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.69, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.58 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Uninsulated Swinging Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.074, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.137, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.055, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.055, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.119, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.053, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.083, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.09, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.069, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.08, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.069, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.35 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.45 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.55 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.35 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.45 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.55 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.8 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.8 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.86, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.54, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.86, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "ext-slab", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 1.17 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.17, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 1.17 SHGC 0.49 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.17, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.98 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.65, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 1.10 SHGC 0.77 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.1, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.62, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 1.10 SHGC 0.77 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.1, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.27, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.69 SHGC 0.49 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.69, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.69 SHGC 0.49 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.69, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Uninsulated Swinging Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.057, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.137, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.049, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.049, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.093, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.034, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.072, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.08, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.069, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.071, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.069, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.35 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.45 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.55 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.35 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.45 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.55 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.65 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.6 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.6, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.65 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.8 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.8 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.9 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.54, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.86, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.52, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.688, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "ext-slab", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 1.17 SHGC 0.49 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.17, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.98 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.87 SHGC 0.71 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.87, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.74 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.74, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.69 SHGC 0.49 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.69, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.58 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.77, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Uninsulated Swinging Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.107, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.049, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.049, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.093, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.034, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.072, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.071, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.057, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.071, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.057, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.042, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.123, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.35 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.4 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.4, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.45 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.35 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.4 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.4, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.45 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.65 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.6 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.6, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.65 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.8 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.8 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.9 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.52, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.843, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.52, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.688, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "ext-slab", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.9, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.092, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 1.17 SHGC 0.68 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.17, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.77, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 1.17 SHGC 0.64 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.17, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.62, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.98 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.87 SHGC 0.77 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.87, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.61 SHGC 0.77 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.61, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.69 SHGC 0.68 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.69, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.69 SHGC 0.64 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.69, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Uninsulated Swinging Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.057, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.087, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.035, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.021, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.035, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.021, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.034, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.071, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.057, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.036, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.057, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.037, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.036, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.104, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.084, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.35 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.4 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.4, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.45 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.35 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.4 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.4, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.45 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.65 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.6 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.6, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.65 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.8 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.8 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.9 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.52, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.688, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.51, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.688, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "ext-slab", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.9, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.075, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.98 SHGC 0.49 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.98 SHGC 0.46 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.46, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.30 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.3, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.61 SHGC 0.77 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.61, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.61 SHGC 0.77 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.61, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.10 SHGC 0.77 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.1, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.71, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.58 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.65, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.58 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.55, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 0.81 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.81, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.093, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.352, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.292, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "ext-slab", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 1.98 SHGC 0.19 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 1.98 SHGC 0.19 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.98 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 1.90 SHGC 0.34 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 1.90 SHGC 0.27 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 1.36 SHGC 0.19 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.041, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.041, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.218, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.1156, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.081, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.094, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.107, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.087, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.069, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.066, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.041, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.041, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.173, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.096, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.053, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.094, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.084, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.123, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.094, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.162, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.4 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.4, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.83 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.83, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.4 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.4, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.77 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.93 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.93, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.83 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.83, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.65 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.65 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.9, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.86, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.65 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.65 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.80 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.77, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.65 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.77, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.65 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.77, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.80 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.65 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.65 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.68, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.80 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.64, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.074, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.074, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.137, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.041, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.041, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.119, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.096, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.053, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.123, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.094, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.077, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.104, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.072, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.162, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.35 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.77 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.35 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.68 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.68, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.87 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.87, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.77 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.6 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.6, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.6 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.6, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.86, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.54, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.86, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.55 SHGC 0.64 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.64, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.55 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.70 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.55 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.55 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.70 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.55 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.55 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.70 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.057, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.107, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.037, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.021, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.037, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.021, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.093, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.082, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.034, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.104, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.06, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.09, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.05, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.162, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.35 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.42 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.42, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.35 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.42 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.42, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.68 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.68, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.51 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.51, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.73 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.73, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.77 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.77 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.81 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.81, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.52, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.843, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.52, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.688, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.9, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.092, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.15 SHGC 0.77 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.15, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.15 SHGC 0.77 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.15, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.15 SHGC 0.77 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.15, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.057, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.107, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.037, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.021, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.037, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.021, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.082, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.034, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.09, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.05, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.055, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.08, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.05, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.055, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.094, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.084, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.32 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.32, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.42 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.42, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.32 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.32, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.42 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.42, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.68 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.68, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.45 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.62 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.62, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.77 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.77 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.7 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.52, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.688, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.51, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.688, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.9, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.092, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.19 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.34 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.34, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.27 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.27, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.087, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.031, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.021, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.029, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.021, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.06, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.034, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.08, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.05, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.049, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.071, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.05, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.049, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.094, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.084, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.32 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.32, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.42 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.42, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.77 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.32 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.32, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.42 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.42, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.68 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.68, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.45 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.51 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.51, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.77 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.59 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.59, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.51, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.688, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.434, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.671, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.86, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.092, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.063, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.19 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 0.85 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.85, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.19 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 0.85 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.85, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 0.85 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.85, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.042, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.042, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.27, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.074, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.028, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.029, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.017, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.028, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.029, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.017, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.037, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.071, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.044, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.049, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.071, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.044, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.042, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.123, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.072, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.32 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.32, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.38 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.38, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.77 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.32 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.32, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.38 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.38, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.68 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.68, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.32 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.32, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.38 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.38, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.77 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.4 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.4, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.4 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.4, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.44 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.44, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.51, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.671, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.434, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.671, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.86, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.063, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.063, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.27 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.27, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.27 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.27, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 0.85 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.85, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 0.85 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.85, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.19 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 0.85 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.85, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.028, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.026, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.017, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.028, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.026, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.017, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.037, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.037, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.037, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.104, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.06, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.32 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.32, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.38 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.38, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.77 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.32 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.32, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.38 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.38, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.68 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.68, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.32 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.32, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.38 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.38, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.77 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.4 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.4, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.4 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.4, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.44 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.44, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.434, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.671, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.424, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.373, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.54, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.86, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.063, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.063, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 0.85 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.85, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.65, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 0.85 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.85, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.27, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 0.85 SHGC 0.65 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.85, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.094, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.352, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.352, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.292, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 1.1 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.1, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 1.1 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.1, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.93 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.93, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.1 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.1, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.65 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.65 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.75 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.75 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.80 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.75 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.75 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.80 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.75 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.68, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.75 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.64, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.80 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.64, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.041, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.041, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.218, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.1156, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.081, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.094, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.107, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.087, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.069, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.066, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.041, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.041, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.173, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.096, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.053, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.094, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.084, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.123, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.094, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.162, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.37 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.54 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.54, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.83 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.83, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.37 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.54 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.54, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.77 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.93 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.93, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.83 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.83, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.65 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.65 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.9, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.86, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.65 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.35, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.65 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.35, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.8 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.55, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.65 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.35, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.65 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.35, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.8 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.55, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.65 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.35, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.65 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.35, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.8 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.55, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.074, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.074, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.137, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.041, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.041, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.119, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.096, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.053, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.123, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.094, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.077, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.104, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.072, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.162, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.33 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.33, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.45 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.77 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.33 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.33, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.45 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.68 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.68, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.87 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.87, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.77 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.6 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.6, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.6 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.6, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.86, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.54, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.86, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.55 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.35, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.55 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.35, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.7 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.55 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.35, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.55 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.35, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.7 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.55 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.35, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.55 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.35, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.7 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.057, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.107, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.037, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.021, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.037, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.021, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.093, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.082, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.034, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.104, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.06, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.09, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.05, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.162, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.31 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.38 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.38, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.31 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.38 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.38, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.68 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.68, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.51 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.51, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.73 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.73, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.77 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.68 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.68, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.81 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.81, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.52, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.843, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.52, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.688, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.9, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.092, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.15 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.15, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.15 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.15, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.15 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.15, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.057, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.107, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.037, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.021, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.037, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.021, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.082, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.034, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.09, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.05, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.055, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.08, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.05, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.055, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.094, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.084, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.31 SHGC 0.38 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.38, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.38 SHGC 0.38 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.38, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.38, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.31 SHGC 0.38 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.38, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.38 SHGC 0.38 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.38, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.38, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.68 SHGC 0.38 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.68, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.38, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.45 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.62 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.62, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.77 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.68 SHGC 0.38 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.68, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.38, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.7 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.52, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.688, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.51, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.688, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.9, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.092, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.087, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.031, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.021, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.029, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.021, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.06, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.034, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.08, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.05, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.049, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.071, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.05, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.049, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.094, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.084, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.3 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.3, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.36 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.68 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.68, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.3 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.3, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.36 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.68 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.68, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.45 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.51 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.51, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.77 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.59 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.59, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.51, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.688, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.434, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.671, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.86, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.092, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.063, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 0.85 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.85, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 0.85 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.85, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 0.85 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.85, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.042, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.042, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.27, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.074, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.028, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.029, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.017, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.028, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.029, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.017, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.037, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.071, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.044, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.049, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.071, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.044, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.042, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.123, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.072, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.28 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.28, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.33 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.33, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.68 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.68, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.28 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.28, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.33 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.33, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.68 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.68, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.32 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.32, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.38 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.38, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.77 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.4 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.4, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.4 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.4, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.44 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.44, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.51, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.671, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.434, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.671, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.86, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.063, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.063, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 0.85 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.85, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 0.85 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.85, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 0.85 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.85, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.028, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.026, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.017, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.028, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.026, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.017, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.037, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.037, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.037, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.104, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.06, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.25 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.25, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.29 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.29, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.68 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.68, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.25 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.25, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.29 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.29, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.68 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.68, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.32 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.32, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.38 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.38, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.77 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.4 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.4, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.4 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.4, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.44 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.44, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.434, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.671, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.424, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.373, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.54, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.86, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.063, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.063, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.41 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.41, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.41 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.41, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 0.85 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.85, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.41 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.41, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.41 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.41, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 0.85 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.85, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.41 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.41, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.41 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.41, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 0.85 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.85, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.094, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.352, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.352, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.292, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 1.1 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.1, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 1.1 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.1, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.93 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.93, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.1 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.1, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.65 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.65 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.75 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.35, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.75 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.35, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.8 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.55, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.75 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.35, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.75 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.35, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.8 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.55, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.75 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.35, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.75 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.35, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.8 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.55, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.041, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.041, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.218, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.1156, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.081, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.094, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.107, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.087, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.069, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.066, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.041, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.041, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.173, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.096, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.053, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.094, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.084, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.123, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.094, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.162, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.45 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.45 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.77 SHGC 0.23 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.23, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Entrance door" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Fixed", + "building_category": "Nonresidential", + "construction": "U 0.45 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Operable", + "building_category": "Nonresidential", + "construction": "U 0.6 SHGC 0.23 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.6, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.23, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Entrance door", + "building_category": "Nonresidential", + "construction": "U 0.77 SHGC 0.23 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.23, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.45 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.45 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.77 SHGC 0.23 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.23, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Entrance door" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Fixed", + "building_category": "Residential", + "construction": "U 0.45 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Operable", + "building_category": "Residential", + "construction": "U 0.6 SHGC 0.23 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.6, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.23, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Entrance door", + "building_category": "Residential", + "construction": "U 0.77 SHGC 0.23 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.23, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.5 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.5 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.77 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Entrance door" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Fixed", + "building_category": "Semiheated", + "construction": "U 0.5 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Operable", + "building_category": "Semiheated", + "construction": "U 0.65 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Entrance door", + "building_category": "Semiheated", + "construction": "U 0.77 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.65 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.65 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.9, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.86, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.65 SHGC 0.3 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.3, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.65 SHGC 0.3 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.3, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 0.9 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.55, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.65 SHGC 0.3 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.3, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.65 SHGC 0.3 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.3, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 0.9 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.55, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.65 SHGC 0.3 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.3, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.65 SHGC 0.3 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.3, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 2", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 0.9 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.55, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.074, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.074, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.137, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.041, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.041, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.119, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.096, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.053, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.123, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.094, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.077, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.104, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.072, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.162, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.42 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.42, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.42 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.42, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.68 SHGC 0.23 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.68, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.23, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Entrance door" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Fixed", + "building_category": "Nonresidential", + "construction": "U 0.42 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.42, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Operable", + "building_category": "Nonresidential", + "construction": "U 0.54 SHGC 0.23 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.54, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.23, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Entrance door", + "building_category": "Nonresidential", + "construction": "U 0.68 SHGC 0.23 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.68, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.23, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.42 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.42, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.42 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.42, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.68 SHGC 0.23 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.68, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.23, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Entrance door" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Fixed", + "building_category": "Residential", + "construction": "U 0.42 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.42, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Operable", + "building_category": "Residential", + "construction": "U 0.54 SHGC 0.23 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.54, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.23, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Entrance door", + "building_category": "Residential", + "construction": "U 0.68 SHGC 0.23 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.68, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.23, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.5 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.5 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.77 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Entrance door" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Fixed", + "building_category": "Semiheated", + "construction": "U 0.5 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Operable", + "building_category": "Semiheated", + "construction": "U 0.65 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Entrance door", + "building_category": "Semiheated", + "construction": "U 0.77 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.6 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.6, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.6 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.6, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.86, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.54, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.86, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.55 SHGC 0.3 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.3, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.55 SHGC 0.3 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.3, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 0.9 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.55 SHGC 0.3 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.3, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.55 SHGC 0.3 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.3, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 0.9 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.55 SHGC 0.3 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.3, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.55 SHGC 0.3 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.55, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.3, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 3", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 0.9 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.057, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.107, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.037, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.021, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.037, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.021, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.093, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.082, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.034, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.104, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.06, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.09, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.05, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.162, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.36 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.36 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.36 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.36 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.63 SHGC 0.33 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.63, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.33, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Entrance door" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Fixed", + "building_category": "Residential", + "construction": "U 0.36 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Operable", + "building_category": "Residential", + "construction": "U 0.45 SHGC 0.33 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.33, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Entrance door", + "building_category": "Residential", + "construction": "U 0.63 SHGC 0.33 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.63, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.33, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.5 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.5 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.77 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Entrance door" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Fixed", + "building_category": "Semiheated", + "construction": "U 0.5 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Operable", + "building_category": "Semiheated", + "construction": "U 0.65 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Entrance door", + "building_category": "Semiheated", + "construction": "U 0.77 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.63 SHGC 0.33 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.63, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.33, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Entrance door" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Fixed", + "building_category": "Nonresidential", + "construction": "U 0.36 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Operable", + "building_category": "Nonresidential", + "construction": "U 0.45 SHGC 0.33 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.33, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Entrance door", + "building_category": "Nonresidential", + "construction": "U 0.63 SHGC 0.33 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.63, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.33, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.81 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.81, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.52, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.843, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.52, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.688, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.9, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.092, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 0.75 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 0.75 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 4", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 0.75 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.057, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.107, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.037, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.021, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.037, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.021, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.082, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.034, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.09, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.05, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.055, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.08, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.05, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.055, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.094, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.084, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.36 SHGC 0.38 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.38, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.36 SHGC 0.38 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.38, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.36 SHGC 0.38 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.38, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.36 SHGC 0.38 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.38, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.63 SHGC 0.33 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.63, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.33, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Entrance door" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Fixed", + "building_category": "Residential", + "construction": "U 0.36 SHGC 0.38 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.38, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Operable", + "building_category": "Residential", + "construction": "U 0.45 SHGC 0.33 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.33, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Entrance door", + "building_category": "Residential", + "construction": "U 0.63 SHGC 0.33 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.63, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.33, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.5 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.5 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.77 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Entrance door" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Fixed", + "building_category": "Semiheated", + "construction": "U 0.5 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Operable", + "building_category": "Semiheated", + "construction": "U 0.65 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Entrance door", + "building_category": "Semiheated", + "construction": "U 0.77 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.77, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.63 SHGC 0.33 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.63, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.33, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Entrance door" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Fixed", + "building_category": "Nonresidential", + "construction": "U 0.36 SHGC 0.38 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.38, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Operable", + "building_category": "Nonresidential", + "construction": "U 0.45 SHGC 0.33 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.33, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Entrance door", + "building_category": "Nonresidential", + "construction": "U 0.63 SHGC 0.33 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.63, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.33, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.7 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.52, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.688, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.51, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.688, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.9, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.092, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 0.75 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 0.75 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 5", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 0.75 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.087, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.031, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.021, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.029, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.021, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.06, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.034, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.08, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.05, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.049, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.071, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.05, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.049, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.094, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.084, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.34 SHGC 0.38 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.34, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.38, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.34 SHGC 0.38 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.34, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.38, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.63 SHGC 0.34 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.63, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.34, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Entrance door" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Fixed", + "building_category": "Nonresidential", + "construction": "U 0.34 SHGC 0.38 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.34, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.38, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Operable", + "building_category": "Nonresidential", + "construction": "U 0.42 SHGC 0.34 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.42, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.34, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Entrance door", + "building_category": "Nonresidential", + "construction": "U 0.63 SHGC 0.34 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.63, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.34, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.34 SHGC 0.38 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.34, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.38, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.34 SHGC 0.38 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.34, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.38, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.63 SHGC 0.34 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.63, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.34, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Entrance door" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Fixed", + "building_category": "Residential", + "construction": "U 0.34 SHGC 0.38 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.34, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.38, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Operable", + "building_category": "Residential", + "construction": "U 0.42 SHGC 0.34 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.42, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.34, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Entrance door", + "building_category": "Residential", + "construction": "U 0.63 SHGC 0.34 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.63, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.34, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.39 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.39, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.39 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.39, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.68 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.68, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Entrance door" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Fixed", + "building_category": "Semiheated", + "construction": "U 0.39 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.39, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Operable", + "building_category": "Semiheated", + "construction": "U 0.48 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.48, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Entrance door", + "building_category": "Semiheated", + "construction": "U 0.68 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.68, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.59 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.59, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.51, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.688, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.434, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.671, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.86, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.092, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.063, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.47 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.47, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 0.75 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.47 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.47, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 0.75 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.47 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.47, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 6", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 0.75 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.042, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.042, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.27, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.074, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.028, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.029, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.017, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.028, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.029, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.017, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.037, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.071, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.044, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.049, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.071, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.044, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.042, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.123, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.072, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.29 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.29, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.29 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.29, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.63 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.63, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Entrance door" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Fixed", + "building_category": "Nonresidential", + "construction": "U 0.29 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.29, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Operable", + "building_category": "Nonresidential", + "construction": "U 0.36 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Entrance door", + "building_category": "Nonresidential", + "construction": "U 0.63 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.63, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.29 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.29, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.29 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.29, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.63 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.63, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Entrance door" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Fixed", + "building_category": "Residential", + "construction": "U 0.26 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.26, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Operable", + "building_category": "Residential", + "construction": "U 0.36 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Entrance door", + "building_category": "Residential", + "construction": "U 0.63 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.63, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.36 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.36 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.63 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.63, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Entrance door" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Fixed", + "building_category": "Semiheated", + "construction": "U 0.36 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Operable", + "building_category": "Semiheated", + "construction": "U 0.44 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.44, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Entrance door", + "building_category": "Semiheated", + "construction": "U 0.63 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.63, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.4 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.4, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.4 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.4, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.44 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.44, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.51, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.671, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.434, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.671, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.86, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.063, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.063, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.44 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.44, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.44 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.44, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 0.75 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.44 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.44, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.44 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.44, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 0.75 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.44 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.44, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.44 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.44, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 7", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 0.75 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.038, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.052, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.028, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.026, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.017, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.028, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.026, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.017, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.037, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.037, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.037, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.104, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.06, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.064, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.051, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.26 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.26, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.26 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.26, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.63 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.63, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Entrance door" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Fixed", + "building_category": "Nonresidential", + "construction": "U 0.26 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.26, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Operable", + "building_category": "Nonresidential", + "construction": "U 0.32 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.32, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Entrance door", + "building_category": "Nonresidential", + "construction": "U 0.63 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.63, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.26 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.26, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.26 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.26, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.63 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.63, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Entrance door" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Fixed", + "building_category": "Residential", + "construction": "U 0.26 SHGC 0.4 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.26, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.4, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Operable", + "building_category": "Residential", + "construction": "U 0.32 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.32, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Entrance door", + "building_category": "Residential", + "construction": "U 0.63 SHGC 0.36 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.63, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.36 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.36 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.63 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.63, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Entrance door" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Fixed", + "building_category": "Semiheated", + "construction": "U 0.36 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Operable", + "building_category": "Semiheated", + "construction": "U 0.44 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.44, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.63 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.63, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.4 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.4, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.4 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.4, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.45, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.44 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.44, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.434, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.671, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.424, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.373, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.54, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.86, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.063, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.063, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 0.119, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.41 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.41, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.41 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.41, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 0.75 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.41 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.41, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.41 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.41, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 0.75 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.41 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.41, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.41 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.41, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 8", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 0.75 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.094, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.352, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.352, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.292, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.23 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.23, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.23 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.23, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.83 SHGC 0.21 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.83, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.21, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Entrance door" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Fixed", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.23 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.23, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Operable", + "building_category": "Nonresidential", + "construction": "U 0.62 SHGC 0.21 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.62, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.21, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Entrance door", + "building_category": "Nonresidential", + "construction": "U 0.83 SHGC 0.21 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.83, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.21, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.23 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.23, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.23 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.23, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.83 SHGC 0.21 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.83, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.21, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Entrance door" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Fixed", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.23 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.23, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Operable", + "building_category": "Residential", + "construction": "U 0.62 SHGC 0.21 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.62, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.21, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Entrance door", + "building_category": "Residential", + "construction": "U 0.83 SHGC 0.21 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.83, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.21, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.1 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.1, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Entrance door" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Fixed", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Operable", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Entrance door", + "building_category": "Semiheated", + "construction": "U 1.1 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.1, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.65 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.65 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.7 SHGC 0.3 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.3, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.7 SHGC 0.3 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.3, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.8 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.55, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.7 SHGC 0.3 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.3, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.7 SHGC 0.3 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.3, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.8 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.55, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.7 SHGC 0.3 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.3, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.7 SHGC 0.3 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.3, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 1", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.8 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.55, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.041, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.041, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.218, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.115, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.081, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.094, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.094, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.352, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.352, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.292, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.32 SHGC 0.22 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.32, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.22, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.22 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.22, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.83 SHGC 0.22 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.83, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.22, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.32 SHGC 0.22 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.32, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.22, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.22 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.22, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.83 SHGC 0.22 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.83, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.22, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.93 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.93, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.1 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.1, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.65 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.65 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.75 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.35, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.75 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.35, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.8 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.55, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.75 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.35, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.75 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.35, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.8 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.55, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.75 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.35, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.75 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.35, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.8 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.55, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.37, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.31, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.041, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.032, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.041, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.218, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.115, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.081, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.094, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.094, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.352, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.352, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.292, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.22 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.22, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.22 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.22, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 0.83 SHGC 0.2 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.83, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.2, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Entrance door" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Fixed", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.22 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.22, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Operable", + "building_category": "Nonresidential", + "construction": "U 0.62 SHGC 0.2 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.62, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.2, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Entrance door", + "building_category": "Nonresidential", + "construction": "U 0.83 SHGC 0.2 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.83, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.2, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.22 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.22, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.22 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.22, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 0.83 SHGC 0.2 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.83, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.2, + "assembly_minimum_vt_shgc": 1.1, + "annotation": "Entrance door" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Fixed", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.22 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.22, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Operable", + "building_category": "Residential", + "construction": "U 0.62 SHGC 0.2 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.62, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.2, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Entrance door", + "building_category": "Residential", + "construction": "U 0.83 SHGC 0.2 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.83, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.2, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Fixed" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.1 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.1, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": "Entrance door" + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Fixed", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Operable", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Entrance door", + "building_category": "Semiheated", + "construction": "U 1.1 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.1, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.65 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.65 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.7 SHGC 0.3 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.3, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.7 SHGC 0.3 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.3, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.8 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.7 SHGC 0.3 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.3, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.7 SHGC 0.3 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.3, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.8 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.7 SHGC 0.3 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.3, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.7 SHGC 0.3 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.3, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.8 SHGC 0.55 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.034, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.614, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.28, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.18, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.352, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.292, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 1.22 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 1.22 SHGC 0.19 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 1, + "maximum_percent_of_surface": 10, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 10.001, + "maximum_percent_of_surface": 20, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 20.001, + "maximum_percent_of_surface": 30, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.22 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 30.001, + "maximum_percent_of_surface": 40, + "assembly_maximum_u_value": 1.22, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 0.98 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": 40.001, + "maximum_percent_of_surface": 100, + "assembly_maximum_u_value": 0.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 1.98 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 1.98 SHGC 0.19 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.98 SHGC 0.16 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.16, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 1.90 SHGC 0.34 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 1.90 SHGC 0.27 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.34, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.27, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 1.36 SHGC 0.19 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.27, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2004", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.034, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.218, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.081, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.28, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.18, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.352, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.292, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.45 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 1.98 SHGC 0.49 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 1.98 SHGC 0.19 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.98 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 1.90 SHGC 0.34 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 1.90 SHGC 0.27 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.77, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.77, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 1.36 SHGC 0.19 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.62, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2007", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Uninsulated Swinging Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.033, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.063, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.034, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.065, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.218, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.081, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.167, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.093, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.093, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.113, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.352, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.292, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "ext-slab", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 1.98 SHGC 0.19 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 1.98 SHGC 0.19 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.98 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.98, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 1.90 SHGC 0.34 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.36, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 1.90 SHGC 0.27 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.9, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.19, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 1.36 SHGC 0.19 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.36, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Nonresidential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Residential", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Residential", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.7, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "NonSwinging", + "building_category": "Semiheated", + "construction": "Typical Overhead Door", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.45, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.322, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.35, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.282, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic ExteriorFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Nonresidential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.048, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.041, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Nonresidential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Residential", + "construction": "Typical IEAD Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.039, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Roof - Highly Reflective", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.041, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Residential", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.027, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "building_category": "Semiheated", + "construction": "Typical IEAD Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.218, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.1156, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Semiheated", + "construction": "Typical Wood Joist Attic Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.081, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "building_category": "Adiabatic", + "construction": "Adiabatic Roof", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Nonresidential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.094, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Nonresidential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.151, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Residential", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.094, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Residential", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.124, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Residential", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.089, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Exterior Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.58, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "building_category": "Semiheated", + "construction": "Typical Insulated Metal Building Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.352, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Steel Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.352, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "building_category": "Semiheated", + "construction": "Typical Insulated Wood Framed Exterior Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.292, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "building_category": "Adiabatic", + "construction": "Adiabatic Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Nonresidential", + "construction": "U 0.5 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Nonresidential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Nonresidential", + "construction": "U 1.1 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.1, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Residential", + "construction": "U 0.5 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.5, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Residential", + "construction": "U 0.57 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.57, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Residential", + "construction": "U 1.1 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.1, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Nonmetal framing (all)", + "building_category": "Semiheated", + "construction": "U 0.93 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.93, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (curtainwall/storefront)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "building_category": "Semiheated", + "construction": "U 1.1 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.1, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Nonresidential", + "construction": "U 0.65 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Residential", + "construction": "U 0.65 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 0.65, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": 1.1, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GlassDoor", + "standards_construction_type": "Metal framing (entrance door)", + "building_category": "Semiheated", + "construction": "U 1.2 SHGC 0.25 Simple Glazing Window", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": 1.2, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.25, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Nonresidential", + "construction": "Typical Insulated Carpeted 8in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Residential", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 0.73, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Heated", + "building_category": "Semiheated", + "construction": "Typical Insulated Carpeted 6in Slab Floor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": 1.02, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Unheated", + "building_category": "Adiabatic", + "construction": "Adiabatic GroundContactFloor", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": 0, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": null, + "u_value_includes_exterior_film_coefficient": null, + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Nonresidential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Residential", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "building_category": "Semiheated", + "construction": "Typical Insulated Basement Mass Wall", + "orientation": null, + "minimum_percent_of_surface": null, + "maximum_percent_of_surface": null, + "assembly_maximum_u_value": null, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": 1.14, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Nonresidential", + "construction": "U 0.75 SHGC 0.45 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Residential", + "construction": "U 0.75 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "building_category": "Semiheated", + "construction": "U 1.80 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.49, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Nonresidential", + "construction": "U 0.75 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.39, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Residential", + "construction": "U 0.75 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Plastic with Curb", + "building_category": "Semiheated", + "construction": "U 1.80 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": null, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Nonresidential", + "construction": "U 0.75 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.68, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Residential", + "construction": "U 0.75 SHGC 0.35 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 0.75, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.64, + "assembly_minimum_vt_shgc": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone_set": "ClimateZone 0", + "intended_surface_type": "Skylight", + "standards_construction_type": "Without Curb", + "building_category": "Semiheated", + "construction": "U 1.80 SHGC 0.36 Simple Glazing Skylight", + "orientation": null, + "minimum_percent_of_surface": 0, + "maximum_percent_of_surface": 2, + "assembly_maximum_u_value": 1.8, + "u_value_includes_interior_film_coefficient": "TRUE", + "u_value_includes_exterior_film_coefficient": "TRUE", + "assembly_maximum_f_factor": null, + "assembly_maximum_c_factor": null, + "assembly_maximum_solar_heat_gain_coefficient": 0.64, + "assembly_minimum_vt_shgc": null, + "annotation": null + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_boilers_90_1.json b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_boilers_90_1.json new file mode 100644 index 0000000000..b867ae631d --- /dev/null +++ b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_boilers_90_1.json @@ -0,0 +1,338 @@ +[ + { + "template": "90.1-2004", + "fluid_type": "Hot Water", + "fuel_type": "Gas", + "condensing": null, + "condensing_control": null, + "minimum_capacity": 0, + "maximum_capacity": 299999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": 0.8, + "minimum_thermal_efficiency": null, + "minimum_combustion_efficiency": null, + "efffplr": "Boiler with No Minimum Turndown", + "annotation": "From 90.1-2004" + }, + { + "template": "90.1-2004", + "fluid_type": "Hot Water", + "fuel_type": "Gas", + "condensing": null, + "condensing_control": null, + "minimum_capacity": 300000, + "maximum_capacity": 249999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": null, + "minimum_thermal_efficiency": 0.75, + "minimum_combustion_efficiency": null, + "efffplr": "Boiler with No Minimum Turndown", + "annotation": "From 90.1-2004" + }, + { + "template": "90.1-2004", + "fluid_type": "Hot Water", + "fuel_type": "Gas", + "condensing": null, + "condensing_control": null, + "minimum_capacity": 250000000, + "maximum_capacity": 9999999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": null, + "minimum_thermal_efficiency": null, + "minimum_combustion_efficiency": 0.8, + "efffplr": "Boiler with No Minimum Turndown", + "annotation": "From 90.1-2004" + }, + { + "template": "90.1-2007", + "fluid_type": "Hot Water", + "fuel_type": "Gas", + "condensing": null, + "condensing_control": null, + "minimum_capacity": 0, + "maximum_capacity": 299999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": 0.8, + "minimum_thermal_efficiency": null, + "minimum_combustion_efficiency": null, + "efffplr": "Boiler with No Minimum Turndown", + "annotation": "From 90.1-2007" + }, + { + "template": "90.1-2007", + "fluid_type": "Hot Water", + "fuel_type": "Gas", + "condensing": null, + "condensing_control": null, + "minimum_capacity": 300000, + "maximum_capacity": 249999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": null, + "minimum_thermal_efficiency": 0.8, + "minimum_combustion_efficiency": null, + "efffplr": "Boiler with No Minimum Turndown", + "annotation": "From 90.1-2007" + }, + { + "template": "90.1-2007", + "fluid_type": "Hot Water", + "fuel_type": "Gas", + "condensing": null, + "condensing_control": null, + "minimum_capacity": 250000000, + "maximum_capacity": 9999999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": null, + "minimum_thermal_efficiency": null, + "minimum_combustion_efficiency": 0.82, + "efffplr": "Boiler with No Minimum Turndown", + "annotation": "From 90.1-2007" + }, + { + "template": "90.1-2010", + "fluid_type": "Hot Water", + "fuel_type": "Gas", + "condensing": null, + "condensing_control": null, + "minimum_capacity": 0, + "maximum_capacity": 299999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": 0.8, + "minimum_thermal_efficiency": null, + "minimum_combustion_efficiency": null, + "efffplr": "Boiler with No Minimum Turndown", + "annotation": "From 90.1-2010" + }, + { + "template": "90.1-2010", + "fluid_type": "Hot Water", + "fuel_type": "Gas", + "condensing": null, + "condensing_control": null, + "minimum_capacity": 300000, + "maximum_capacity": 249999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": null, + "minimum_thermal_efficiency": 0.8, + "minimum_combustion_efficiency": null, + "efffplr": "Boiler with No Minimum Turndown", + "annotation": "From 90.1-2010" + }, + { + "template": "90.1-2010", + "fluid_type": "Hot Water", + "fuel_type": "Gas", + "condensing": null, + "condensing_control": null, + "minimum_capacity": 250000000, + "maximum_capacity": 9999999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": null, + "minimum_thermal_efficiency": null, + "minimum_combustion_efficiency": 0.82, + "efffplr": "Boiler with No Minimum Turndown", + "annotation": "From 90.1-2010" + }, + { + "template": "90.1-2013", + "fluid_type": "Hot Water", + "fuel_type": "Gas", + "condensing": null, + "condensing_control": null, + "minimum_capacity": 0, + "maximum_capacity": 299999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": 0.82, + "minimum_thermal_efficiency": null, + "minimum_combustion_efficiency": null, + "efffplr": "Boiler with No Minimum Turndown", + "annotation": "From 90.1-2013" + }, + { + "template": "90.1-2013", + "fluid_type": "Hot Water", + "fuel_type": "Gas", + "condensing": null, + "condensing_control": null, + "minimum_capacity": 300000, + "maximum_capacity": 999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": null, + "minimum_thermal_efficiency": 0.8, + "minimum_combustion_efficiency": null, + "efffplr": "Boiler with No Minimum Turndown", + "annotation": "From 90.1-2013" + }, + { + "template": "90.1-2013", + "fluid_type": "Hot Water", + "fuel_type": "Gas", + "condensing": null, + "condensing_control": null, + "minimum_capacity": 1000000, + "maximum_capacity": 249999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": null, + "minimum_thermal_efficiency": 0.8, + "minimum_combustion_efficiency": null, + "efffplr": "Boiler with Minimum Turndown", + "annotation": "From 90.1-2013" + }, + { + "template": "90.1-2013", + "fluid_type": "Hot Water", + "fuel_type": "Gas", + "condensing": null, + "condensing_control": null, + "minimum_capacity": 250000000, + "maximum_capacity": 9999999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": null, + "minimum_thermal_efficiency": null, + "minimum_combustion_efficiency": 0.82, + "efffplr": "Boiler with Minimum Turndown", + "annotation": "From 90.1-2013" + }, + { + "template": "90.1-2016", + "fluid_type": "Hot Water", + "fuel_type": "Gas", + "condensing": null, + "condensing_control": null, + "minimum_capacity": 0, + "maximum_capacity": 299999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": 0.82, + "minimum_thermal_efficiency": null, + "minimum_combustion_efficiency": null, + "efffplr": "Boiler with No Minimum Turndown", + "annotation": "From 90.1-2016" + }, + { + "template": "90.1-2016", + "fluid_type": "Hot Water", + "fuel_type": "Gas", + "condensing": null, + "condensing_control": null, + "minimum_capacity": 300000, + "maximum_capacity": 999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": null, + "minimum_thermal_efficiency": 0.8, + "minimum_combustion_efficiency": null, + "efffplr": "Boiler with No Minimum Turndown", + "annotation": "From 90.1-2016" + }, + { + "template": "90.1-2016", + "fluid_type": "Hot Water", + "fuel_type": "Gas", + "condensing": null, + "condensing_control": null, + "minimum_capacity": 1000000, + "maximum_capacity": 249999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": null, + "minimum_thermal_efficiency": 0.8, + "minimum_combustion_efficiency": null, + "efffplr": "Boiler with Minimum Turndown", + "annotation": "From 90.1-2016" + }, + { + "template": "90.1-2016", + "fluid_type": "Hot Water", + "fuel_type": "Gas", + "condensing": null, + "condensing_control": null, + "minimum_capacity": 250000000, + "maximum_capacity": 9999999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": null, + "minimum_thermal_efficiency": null, + "minimum_combustion_efficiency": 0.82, + "efffplr": "Boiler with Minimum Turndown", + "annotation": "From 90.1-2016" + }, + { + "template": "90.1-2019", + "fluid_type": "Hot Water", + "fuel_type": "Gas", + "condensing": null, + "condensing_control": null, + "minimum_capacity": 0, + "maximum_capacity": 299999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": 0.84, + "minimum_thermal_efficiency": null, + "minimum_combustion_efficiency": null, + "efffplr": "Boiler with No Minimum Turndown", + "annotation": "From 90.1-2019" + }, + { + "template": "90.1-2019", + "fluid_type": "Hot Water", + "fuel_type": "Gas", + "condensing": null, + "condensing_control": null, + "minimum_capacity": 300000, + "maximum_capacity": 999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": null, + "minimum_thermal_efficiency": 0.8, + "minimum_combustion_efficiency": null, + "efffplr": "Boiler with No Minimum Turndown", + "annotation": "From 90.1-2019" + }, + { + "template": "90.1-2019", + "fluid_type": "Hot Water", + "fuel_type": "Gas", + "condensing": null, + "condensing_control": null, + "minimum_capacity": 1000000, + "maximum_capacity": 249999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": null, + "minimum_thermal_efficiency": 0.8, + "minimum_combustion_efficiency": null, + "efffplr": "Boiler with Minimum Turndown", + "annotation": "From 90.1-2019" + }, + { + "template": "90.1-2019", + "fluid_type": "Hot Water", + "fuel_type": "Gas", + "condensing": null, + "condensing_control": null, + "minimum_capacity": 250000000, + "maximum_capacity": 9999999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": null, + "minimum_thermal_efficiency": null, + "minimum_combustion_efficiency": 0.82, + "efffplr": "Boiler with Minimum Turndown", + "annotation": "From 90.1-2019" + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_chillers_90_1.json b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_chillers_90_1.json new file mode 100644 index 0000000000..eddc9d40de --- /dev/null +++ b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_chillers_90_1.json @@ -0,0 +1,2918 @@ +[ + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "condenser_type": "WithCondenser", + "compressor_type": null, + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 1.256, + "minimum_integrated_part_load_value": 1.153, + "capft": "AirCooled_Chiller_2010_PathA_CAPFT", + "eirft": "AirCooled_Chiller_2010_PathA_EIRFT", + "eirfplr": "AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "condenser_type": "WithoutCondenser", + "compressor_type": null, + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 1.135, + "minimum_integrated_part_load_value": 1.019, + "capft": "ChlrAirRecipQRatio_fTchwsToadbSI", + "eirft": "ChlrAirRecipEIRRatio_fTchwsToadbSI", + "eirfplr": "ChlrAirRecipEIRRatio_fQRatio", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "condenser_type": null, + "compressor_type": null, + "absorption_type": "Single Effect", + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 5.862, + "minimum_integrated_part_load_value": null, + "capft": null, + "eirft": null, + "eirfplr": null, + "annotation": null + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "condenser_type": "WithCondenser", + "compressor_type": null, + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 1.29, + "minimum_integrated_part_load_value": 1.164, + "capft": "AirCooled_Chiller_2010_PathA_CAPFT", + "eirft": "AirCooled_Chiller_2010_PathA_EIRFT", + "eirfplr": "AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR", + "annotation": "Form 90.1-2007 Table 6.8.1A" + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "condenser_type": "WithCondenser", + "compressor_type": null, + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 1.255, + "minimum_integrated_part_load_value": 0.941, + "capft": "AirCooled_Chiller_2010_PathA_CAPFT", + "eirft": "AirCooled_Chiller_2010_PathA_EIRFT", + "eirfplr": "AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR", + "annotation": null + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "condenser_type": "WithCondenser", + "compressor_type": null, + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 1.255, + "minimum_integrated_part_load_value": 0.941, + "capft": "AirCooled_Chiller_2010_PathA_CAPFT", + "eirft": "AirCooled_Chiller_2010_PathA_EIRFT", + "eirfplr": "AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR", + "annotation": null + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "condenser_type": "WithoutCondenser", + "compressor_type": null, + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 1.255, + "minimum_integrated_part_load_value": 0.941, + "capft": "AirCooled_Chiller_2010_PathA_CAPFT", + "eirft": "AirCooled_Chiller_2010_PathA_EIRFT", + "eirfplr": "AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR", + "annotation": null + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "condenser_type": null, + "compressor_type": null, + "absorption_type": "Single Effect", + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 5.862, + "minimum_integrated_part_load_value": null, + "capft": null, + "eirft": null, + "eirfplr": null, + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "condenser_type": "WithCondenser", + "compressor_type": null, + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_full_load_efficiency": 1.25, + "minimum_integrated_part_load_value": 0.96, + "capft": "AirCooled_Chiller_2010_PathA_CAPFT", + "eirft": "AirCooled_Chiller_2010_PathA_EIRFT", + "eirfplr": "AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "condenser_type": "WithCondenser", + "compressor_type": null, + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_full_load_efficiency": 1.25, + "minimum_integrated_part_load_value": 0.94, + "capft": "AirCooled_Chiller_2010_PathA_CAPFT", + "eirft": "AirCooled_Chiller_2010_PathA_EIRFT", + "eirfplr": "AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "condenser_type": "WithoutCondenser", + "compressor_type": null, + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_full_load_efficiency": 1.25, + "minimum_integrated_part_load_value": 0.96, + "capft": "ChlrAirScrollQRatio_fTchwsToadbSI", + "eirft": "ChlrAirScrollEIRRatio_fTchwsToadbSI", + "eirfplr": "ChlrAirScrollEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "condenser_type": "WithoutCondenser", + "compressor_type": null, + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_full_load_efficiency": 1.25, + "minimum_integrated_part_load_value": 0.94, + "capft": "ChlrAirScrollQRatio_fTchwsToadbSI", + "eirft": "ChlrAirScrollEIRRatio_fTchwsToadbSI", + "eirfplr": "ChlrAirScrollEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "condenser_type": null, + "compressor_type": null, + "absorption_type": "Single Effect", + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_full_load_efficiency": 5.862, + "minimum_integrated_part_load_value": null, + "capft": null, + "eirft": null, + "eirfplr": null, + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "condenser_type": "WithCondenser", + "compressor_type": null, + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 149.99, + "start_date": "1/1/2015", + "end_date": "12/31/2014", + "minimum_full_load_efficiency": 1.188, + "minimum_integrated_part_load_value": 0.876, + "capft": "AirCooled_Chiller_2010_PathA_CAPFT", + "eirft": "AirCooled_Chiller_2010_PathA_EIRFT", + "eirfplr": "AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "condenser_type": "WithCondenser", + "compressor_type": null, + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 9999, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 1.188, + "minimum_integrated_part_load_value": 0.857, + "capft": "AirCooled_Chiller_2010_PathA_CAPFT", + "eirft": "AirCooled_Chiller_2010_PathA_EIRFT", + "eirfplr": "AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "condenser_type": "WithoutCondenser", + "compressor_type": null, + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 149.99, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 1.188, + "minimum_integrated_part_load_value": 0.876, + "capft": "ChlrAirScrollQRatio_fTchwsToadbSI", + "eirft": "ChlrAirScrollEIRRatio_fTchwsToadbSI", + "eirfplr": "ChlrAirScrollEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "condenser_type": "WithoutCondenser", + "compressor_type": null, + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 9999, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 1.188, + "minimum_integrated_part_load_value": 0.857, + "capft": "ChlrAirScrollQRatio_fTchwsToadbSI", + "eirft": "ChlrAirScrollEIRRatio_fTchwsToadbSI", + "eirfplr": "ChlrAirScrollEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "condenser_type": null, + "compressor_type": null, + "absorption_type": "Single Effect", + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 9999, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 5.862, + "minimum_integrated_part_load_value": null, + "capft": null, + "eirft": null, + "eirfplr": null, + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2004", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.837, + "minimum_integrated_part_load_value": 0.696, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.837, + "minimum_integrated_part_load_value": 0.696, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.79, + "minimum_integrated_part_load_value": 0.676, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 299.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.718, + "minimum_integrated_part_load_value": 0.628, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 300, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.639, + "minimum_integrated_part_load_value": 0.572, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.79, + "minimum_integrated_part_load_value": 0.676, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 299.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.718, + "minimum_integrated_part_load_value": 0.628, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 300, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.639, + "minimum_integrated_part_load_value": 0.572, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Centrifugal", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 299.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.634, + "minimum_integrated_part_load_value": 0.596, + "capft": "WaterCooled_Centrifugal_Chiller_LT150_2004_CAPFT", + "eirft": "WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFT", + "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Centrifugal", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.703, + "minimum_integrated_part_load_value": 0.67, + "capft": "WaterCooled_Centrifugal_Chiller_LT150_2004_CAPFT", + "eirft": "WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFT", + "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Centrifugal", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 300, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.577, + "minimum_integrated_part_load_value": 0.55, + "capft": "WaterCooled_Centrifugal_Chiller_GT150_2004_CAPFT", + "eirft": "WaterCooled_Centrifugal_Chiller_GT150_2004_EIRFT", + "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": null, + "absorption_type": "Single Effect", + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 5.024, + "minimum_integrated_part_load_value": null, + "capft": null, + "eirft": null, + "eirfplr": null, + "annotation": null + }, + { + "template": "90.1-2007", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 74.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.78, + "minimum_integrated_part_load_value": 0.63, + "capft": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT", + "eirft": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2007", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 75, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.775, + "minimum_integrated_part_load_value": 0.615, + "capft": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT", + "eirft": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2007", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 299.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.68, + "minimum_integrated_part_load_value": 0.58, + "capft": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT", + "eirft": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2007", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 300, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.62, + "minimum_integrated_part_load_value": 0.54, + "capft": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT", + "eirft": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2007", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 74.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.78, + "minimum_integrated_part_load_value": 0.63, + "capft": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT", + "eirft": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2007", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 75, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.775, + "minimum_integrated_part_load_value": 0.615, + "capft": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT", + "eirft": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2007", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 299.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.68, + "minimum_integrated_part_load_value": 0.58, + "capft": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT", + "eirft": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2007", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 300, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.62, + "minimum_integrated_part_load_value": 0.54, + "capft": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT", + "eirft": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2007", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 74.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.78, + "minimum_integrated_part_load_value": 0.63, + "capft": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT", + "eirft": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2007", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 75, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.775, + "minimum_integrated_part_load_value": 0.615, + "capft": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT", + "eirft": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2007", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 299.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.68, + "minimum_integrated_part_load_value": 0.58, + "capft": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT", + "eirft": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2007", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 300, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.62, + "minimum_integrated_part_load_value": 0.54, + "capft": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT", + "eirft": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2007", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Centrifugal", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.634, + "minimum_integrated_part_load_value": 0.596, + "capft": "WaterCooled_Centrifugal_Chiller_LT150_2004_CAPFT", + "eirft": "WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFT", + "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2007", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Centrifugal", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 299.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.634, + "minimum_integrated_part_load_value": 0.596, + "capft": "WaterCooled_Centrifugal_Chiller_LT150_2004_CAPFT", + "eirft": "WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFT", + "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2007", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Centrifugal", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 300, + "maximum_capacity": 599.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.576, + "minimum_integrated_part_load_value": 0.549, + "capft": "WaterCooled_Centrifugal_Chiller_GT150_2004_CAPFT", + "eirft": "WaterCooled_Centrifugal_Chiller_GT150_2004_EIRFT", + "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2007", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Centrifugal", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 600, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.57, + "minimum_integrated_part_load_value": 0.539, + "capft": "WaterCooled_Centrifugal_Chiller_GT150_2004_CAPFT", + "eirft": "WaterCooled_Centrifugal_Chiller_GT150_2004_EIRFT", + "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2010", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 74.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.78, + "minimum_integrated_part_load_value": 0.63, + "capft": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT", + "eirft": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2010", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 75, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.775, + "minimum_integrated_part_load_value": 0.615, + "capft": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT", + "eirft": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2010", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 299.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.68, + "minimum_integrated_part_load_value": 0.58, + "capft": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT", + "eirft": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2010", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 300, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.62, + "minimum_integrated_part_load_value": 0.54, + "capft": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT", + "eirft": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2010", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 74.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.78, + "minimum_integrated_part_load_value": 0.63, + "capft": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT", + "eirft": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2010", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 75, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.775, + "minimum_integrated_part_load_value": 0.615, + "capft": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT", + "eirft": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2010", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 299.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.68, + "minimum_integrated_part_load_value": 0.58, + "capft": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT", + "eirft": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2010", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 300, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.62, + "minimum_integrated_part_load_value": 0.54, + "capft": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT", + "eirft": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2010", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 74.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.78, + "minimum_integrated_part_load_value": 0.63, + "capft": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT", + "eirft": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2010", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 75, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.775, + "minimum_integrated_part_load_value": 0.615, + "capft": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT", + "eirft": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2010", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 299.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.68, + "minimum_integrated_part_load_value": 0.58, + "capft": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT", + "eirft": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2010", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 300, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.62, + "minimum_integrated_part_load_value": 0.54, + "capft": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT", + "eirft": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2010", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Centrifugal", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.634, + "minimum_integrated_part_load_value": 0.596, + "capft": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT", + "eirft": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2010", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Centrifugal", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 299.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.634, + "minimum_integrated_part_load_value": 0.596, + "capft": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT", + "eirft": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2010", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Centrifugal", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 300, + "maximum_capacity": 599.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.576, + "minimum_integrated_part_load_value": 0.549, + "capft": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT", + "eirft": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2010", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Centrifugal", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 600, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.57, + "minimum_integrated_part_load_value": 0.539, + "capft": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT", + "eirft": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio", + "annotation": "Path A Minimum Efficiencies" + }, + { + "template": "90.1-2010", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": null, + "absorption_type": "Single Effect", + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 5.024, + "minimum_integrated_part_load_value": null, + "capft": null, + "eirft": null, + "eirfplr": null, + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 74.99, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_full_load_efficiency": 0.78, + "minimum_integrated_part_load_value": 0.63, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 75, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_full_load_efficiency": 0.775, + "minimum_integrated_part_load_value": 0.615, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 299.99, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_full_load_efficiency": 0.68, + "minimum_integrated_part_load_value": 0.58, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 300, + "maximum_capacity": 599.99, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_full_load_efficiency": 0.62, + "minimum_integrated_part_load_value": 0.54, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 600, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_full_load_efficiency": 0.62, + "minimum_integrated_part_load_value": 0.54, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 74.99, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_full_load_efficiency": 0.78, + "minimum_integrated_part_load_value": 0.63, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 75, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_full_load_efficiency": 0.775, + "minimum_integrated_part_load_value": 0.615, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 299.99, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_full_load_efficiency": 0.68, + "minimum_integrated_part_load_value": 0.58, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 300, + "maximum_capacity": 599.99, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_full_load_efficiency": 0.62, + "minimum_integrated_part_load_value": 0.54, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 600, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_full_load_efficiency": 0.62, + "minimum_integrated_part_load_value": 0.54, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 74.99, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_full_load_efficiency": 0.78, + "minimum_integrated_part_load_value": 0.63, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 75, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_full_load_efficiency": 0.775, + "minimum_integrated_part_load_value": 0.615, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 299.99, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_full_load_efficiency": 0.68, + "minimum_integrated_part_load_value": 0.58, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 300, + "maximum_capacity": 599.99, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_full_load_efficiency": 0.62, + "minimum_integrated_part_load_value": 0.54, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 600, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_full_load_efficiency": 0.62, + "minimum_integrated_part_load_value": 0.54, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Centrifugal", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_full_load_efficiency": 0.634, + "minimum_integrated_part_load_value": 0.596, + "capft": "WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT", + "eirft": "WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Centrifugal", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 399.99, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_full_load_efficiency": 0.634, + "minimum_integrated_part_load_value": 0.596, + "capft": "WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT", + "eirft": "WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Centrifugal", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 400, + "maximum_capacity": 599.99, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_full_load_efficiency": 0.576, + "minimum_integrated_part_load_value": 0.549, + "capft": "WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT", + "eirft": "WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT", + "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Centrifugal", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 600, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_full_load_efficiency": 0.57, + "minimum_integrated_part_load_value": 0.539, + "capft": "WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT", + "eirft": "WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT", + "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio", + "annotation": "Add but unsure what to put for Minimum full load efficiency and min IPLV" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": null, + "absorption_type": "Single Effect", + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 5.024, + "minimum_integrated_part_load_value": null, + "capft": null, + "eirft": null, + "eirfplr": null, + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 74.99, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.75, + "minimum_integrated_part_load_value": 0.6, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 75, + "maximum_capacity": 149.99, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.72, + "minimum_integrated_part_load_value": 0.56, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 299.99, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.66, + "minimum_integrated_part_load_value": 0.54, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 300, + "maximum_capacity": 599.99, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.61, + "minimum_integrated_part_load_value": 0.52, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 600, + "maximum_capacity": 9999, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.56, + "minimum_integrated_part_load_value": 0.5, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 74.99, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.75, + "minimum_integrated_part_load_value": 0.6, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 75, + "maximum_capacity": 149.99, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.72, + "minimum_integrated_part_load_value": 0.56, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 299.99, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.66, + "minimum_integrated_part_load_value": 0.54, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 300, + "maximum_capacity": 599.99, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.61, + "minimum_integrated_part_load_value": 0.52, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 600, + "maximum_capacity": 9999, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.56, + "minimum_integrated_part_load_value": 0.5, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 74.99, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.75, + "minimum_integrated_part_load_value": 0.6, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 75, + "maximum_capacity": 149.99, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.72, + "minimum_integrated_part_load_value": 0.56, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 299.99, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.66, + "minimum_integrated_part_load_value": 0.54, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 300, + "maximum_capacity": 599.99, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.61, + "minimum_integrated_part_load_value": 0.52, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 600, + "maximum_capacity": 9999, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.56, + "minimum_integrated_part_load_value": 0.5, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Centrifugal", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 149.99, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.61, + "minimum_integrated_part_load_value": 0.55, + "capft": "WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT", + "eirft": "WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Centrifugal", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 399.99, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.56, + "minimum_integrated_part_load_value": 0.52, + "capft": "WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT", + "eirft": "WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Centrifugal", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 400, + "maximum_capacity": 599.99, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.56, + "minimum_integrated_part_load_value": 0.5, + "capft": "WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT", + "eirft": "WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT", + "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Centrifugal", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 600, + "maximum_capacity": 9999, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.56, + "minimum_integrated_part_load_value": 0.5, + "capft": "WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT", + "eirft": "WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT", + "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio", + "annotation": "Add but unsure what to put for Minimum full load efficiency and min IPLV" + }, + { + "template": "90.1-2004", + "cooling_type": null, + "condenser_type": null, + "compressor_type": null, + "absorption_type": "Double Effect Indirect Fired", + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 3.517, + "minimum_integrated_part_load_value": 3.35, + "capft": null, + "eirft": null, + "eirfplr": null, + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": null, + "condenser_type": null, + "compressor_type": null, + "absorption_type": "Double Effect Direct Fired", + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 3.517, + "minimum_integrated_part_load_value": 3.517, + "capft": null, + "eirft": null, + "eirfplr": null, + "annotation": null + }, + { + "template": "90.1-2010", + "cooling_type": null, + "condenser_type": null, + "compressor_type": null, + "absorption_type": "Double Effect Indirect Fired", + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 3.517, + "minimum_integrated_part_load_value": 3.35, + "capft": null, + "eirft": null, + "eirfplr": null, + "annotation": null + }, + { + "template": "90.1-2010", + "cooling_type": null, + "condenser_type": null, + "compressor_type": null, + "absorption_type": "Double Effect Direct Fired", + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 3.517, + "minimum_integrated_part_load_value": 3.517, + "capft": null, + "eirft": null, + "eirfplr": null, + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": null, + "condenser_type": null, + "compressor_type": null, + "absorption_type": "Double Effect Indirect Fired", + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 3.517, + "minimum_integrated_part_load_value": 3.35, + "capft": null, + "eirft": null, + "eirfplr": null, + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2013", + "cooling_type": null, + "condenser_type": null, + "compressor_type": null, + "absorption_type": "Double Effect Direct Fired", + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 3.517, + "minimum_integrated_part_load_value": 3.517, + "capft": null, + "eirft": null, + "eirfplr": null, + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "condenser_type": "WithCondenser", + "compressor_type": null, + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 1.188, + "minimum_integrated_part_load_value": 0.876, + "capft": "AirCooled_Chiller_2010_PathA_CAPFT", + "eirft": "AirCooled_Chiller_2010_PathA_EIRFT", + "eirfplr": "AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "condenser_type": "WithCondenser", + "compressor_type": null, + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 1.188, + "minimum_integrated_part_load_value": 0.857, + "capft": "AirCooled_Chiller_2010_PathA_CAPFT", + "eirft": "AirCooled_Chiller_2010_PathA_EIRFT", + "eirfplr": "AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "condenser_type": "WithoutCondenser", + "compressor_type": null, + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 1.188, + "minimum_integrated_part_load_value": 0.876, + "capft": "ChlrAirScrollQRatio_fTchwsToadbSI", + "eirft": "ChlrAirScrollEIRRatio_fTchwsToadbSI", + "eirfplr": "ChlrAirScrollEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "condenser_type": "WithoutCondenser", + "compressor_type": null, + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 1.188, + "minimum_integrated_part_load_value": 0.857, + "capft": "ChlrAirScrollQRatio_fTchwsToadbSI", + "eirft": "ChlrAirScrollEIRRatio_fTchwsToadbSI", + "eirfplr": "ChlrAirScrollEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "condenser_type": null, + "compressor_type": null, + "absorption_type": "Single Effect", + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 5.862, + "minimum_integrated_part_load_value": null, + "capft": null, + "eirft": null, + "eirfplr": null, + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2016", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": null, + "absorption_type": "Single Effect", + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 5.024, + "minimum_integrated_part_load_value": null, + "capft": null, + "eirft": null, + "eirfplr": null, + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2016", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 74.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.75, + "minimum_integrated_part_load_value": 0.6, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2016", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 75, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.72, + "minimum_integrated_part_load_value": 0.56, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2016", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 299.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.66, + "minimum_integrated_part_load_value": 0.54, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2016", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 300, + "maximum_capacity": 599.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.61, + "minimum_integrated_part_load_value": 0.52, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2016", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 600, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.56, + "minimum_integrated_part_load_value": 0.5, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2016", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 74.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.75, + "minimum_integrated_part_load_value": 0.6, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2016", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 75, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.72, + "minimum_integrated_part_load_value": 0.56, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2016", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 299.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.66, + "minimum_integrated_part_load_value": 0.54, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2016", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 300, + "maximum_capacity": 599.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.61, + "minimum_integrated_part_load_value": 0.52, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2016", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 600, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.56, + "minimum_integrated_part_load_value": 0.5, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2016", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 74.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.75, + "minimum_integrated_part_load_value": 0.6, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2016", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 75, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.72, + "minimum_integrated_part_load_value": 0.56, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2016", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 299.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.66, + "minimum_integrated_part_load_value": 0.54, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2016", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 300, + "maximum_capacity": 599.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.61, + "minimum_integrated_part_load_value": 0.52, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2016", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 600, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.56, + "minimum_integrated_part_load_value": 0.5, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2016", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Centrifugal", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.61, + "minimum_integrated_part_load_value": 0.55, + "capft": "WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT", + "eirft": "WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2016", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Centrifugal", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 399.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.56, + "minimum_integrated_part_load_value": 0.52, + "capft": "WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT", + "eirft": "WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2016", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Centrifugal", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 400, + "maximum_capacity": 599.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.56, + "minimum_integrated_part_load_value": 0.5, + "capft": "WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT", + "eirft": "WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT", + "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2016", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Centrifugal", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 600, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.56, + "minimum_integrated_part_load_value": 0.5, + "capft": "WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT", + "eirft": "WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT", + "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2016", + "cooling_type": null, + "condenser_type": null, + "compressor_type": null, + "absorption_type": "Double Effect Indirect Fired", + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 3.517, + "minimum_integrated_part_load_value": 3.35, + "capft": null, + "eirft": null, + "eirfplr": null, + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2016", + "cooling_type": null, + "condenser_type": null, + "compressor_type": null, + "absorption_type": "Double Effect Direct Fired", + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 3.517, + "minimum_integrated_part_load_value": 3.517, + "capft": null, + "eirft": null, + "eirfplr": null, + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "condenser_type": "WithCondenser", + "compressor_type": null, + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 1.188, + "minimum_integrated_part_load_value": 0.876, + "capft": "AirCooled_Chiller_2010_PathA_CAPFT", + "eirft": "AirCooled_Chiller_2010_PathA_EIRFT", + "eirfplr": "AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "condenser_type": "WithCondenser", + "compressor_type": null, + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 1.188, + "minimum_integrated_part_load_value": 0.857, + "capft": "AirCooled_Chiller_2010_PathA_CAPFT", + "eirft": "AirCooled_Chiller_2010_PathA_EIRFT", + "eirfplr": "AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "condenser_type": "WithoutCondenser", + "compressor_type": null, + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 1.188, + "minimum_integrated_part_load_value": 0.876, + "capft": "ChlrAirScrollQRatio_fTchwsToadbSI", + "eirft": "ChlrAirScrollEIRRatio_fTchwsToadbSI", + "eirfplr": "ChlrAirScrollEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "condenser_type": "WithoutCondenser", + "compressor_type": null, + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 1.188, + "minimum_integrated_part_load_value": 0.857, + "capft": "ChlrAirScrollQRatio_fTchwsToadbSI", + "eirft": "ChlrAirScrollEIRRatio_fTchwsToadbSI", + "eirfplr": "ChlrAirScrollEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "condenser_type": null, + "compressor_type": null, + "absorption_type": "Single Effect", + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 5.862, + "minimum_integrated_part_load_value": null, + "capft": null, + "eirft": null, + "eirfplr": null, + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2019", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": null, + "absorption_type": "Single Effect", + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 5.024, + "minimum_integrated_part_load_value": null, + "capft": null, + "eirft": null, + "eirfplr": null, + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2019", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 74.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.75, + "minimum_integrated_part_load_value": 0.6, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2019", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 75, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.72, + "minimum_integrated_part_load_value": 0.56, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2019", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 299.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.66, + "minimum_integrated_part_load_value": 0.54, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2019", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 300, + "maximum_capacity": 599.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.61, + "minimum_integrated_part_load_value": 0.52, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2019", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Reciprocating", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 600, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.56, + "minimum_integrated_part_load_value": 0.5, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2019", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 74.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.75, + "minimum_integrated_part_load_value": 0.6, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2019", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 75, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.72, + "minimum_integrated_part_load_value": 0.56, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2019", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 299.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.66, + "minimum_integrated_part_load_value": 0.54, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2019", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 300, + "maximum_capacity": 599.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.61, + "minimum_integrated_part_load_value": 0.52, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2019", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Scroll", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 600, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.56, + "minimum_integrated_part_load_value": 0.5, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2019", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 74.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.75, + "minimum_integrated_part_load_value": 0.6, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2019", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 75, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.72, + "minimum_integrated_part_load_value": 0.56, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2019", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 299.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.66, + "minimum_integrated_part_load_value": 0.54, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2019", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 300, + "maximum_capacity": 599.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.61, + "minimum_integrated_part_load_value": 0.52, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2019", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Rotary Screw", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 600, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.56, + "minimum_integrated_part_load_value": 0.5, + "capft": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "eirft": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "eirfplr": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2019", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Centrifugal", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 149.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.61, + "minimum_integrated_part_load_value": 0.55, + "capft": "WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT", + "eirft": "WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2019", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Centrifugal", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 150, + "maximum_capacity": 399.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.56, + "minimum_integrated_part_load_value": 0.52, + "capft": "WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT", + "eirft": "WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT", + "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2019", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Centrifugal", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 400, + "maximum_capacity": 599.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.56, + "minimum_integrated_part_load_value": 0.5, + "capft": "WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT", + "eirft": "WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT", + "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2019", + "cooling_type": "WaterCooled", + "condenser_type": null, + "compressor_type": "Centrifugal", + "absorption_type": null, + "variable_speed_drive": null, + "minimum_capacity": 600, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 0.56, + "minimum_integrated_part_load_value": 0.5, + "capft": "WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT", + "eirft": "WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT", + "eirfplr": "ChlrWtrCentPathAAllEIRRatio_fQRatio", + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2019", + "cooling_type": null, + "condenser_type": null, + "compressor_type": null, + "absorption_type": "Double Effect Indirect Fired", + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 3.517, + "minimum_integrated_part_load_value": 3.35, + "capft": null, + "eirft": null, + "eirfplr": null, + "annotation": "Path A Efficiencies" + }, + { + "template": "90.1-2019", + "cooling_type": null, + "condenser_type": null, + "compressor_type": null, + "absorption_type": "Double Effect Direct Fired", + "variable_speed_drive": null, + "minimum_capacity": 0, + "maximum_capacity": 9999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 3.517, + "minimum_integrated_part_load_value": 3.517, + "capft": null, + "eirft": null, + "eirfplr": null, + "annotation": "Path A Efficiencies" + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_furnaces_90_1.json b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_furnaces_90_1.json new file mode 100644 index 0000000000..047139aff9 --- /dev/null +++ b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_furnaces_90_1.json @@ -0,0 +1,134 @@ +[ + { + "template": "90.1-2004", + "minimum_capacity": 0, + "maximum_capacity": 224999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": 0.78, + "minimum_thermal_efficiency": 0.8, + "minimum_combustion_efficiency": null, + "annotation": "Table 6.8.1E page 49" + }, + { + "template": "90.1-2004", + "minimum_capacity": 225000, + "maximum_capacity": 249999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": null, + "minimum_thermal_efficiency": null, + "minimum_combustion_efficiency": 0.8, + "annotation": "Table 6.8.1E page 49" + }, + { + "template": "90.1-2007", + "minimum_capacity": 0, + "maximum_capacity": 224999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": 0.78, + "minimum_thermal_efficiency": 0.8, + "minimum_combustion_efficiency": null, + "annotation": "Table 6.8.1E page 49" + }, + { + "template": "90.1-2007", + "minimum_capacity": 225000, + "maximum_capacity": 249999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": null, + "minimum_thermal_efficiency": null, + "minimum_combustion_efficiency": 0.8, + "annotation": "Table 6.8.1E page 49" + }, + { + "template": "90.1-2010", + "minimum_capacity": 0, + "maximum_capacity": 224999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": 0.78, + "minimum_thermal_efficiency": 0.8, + "minimum_combustion_efficiency": null, + "annotation": "Table 6.8.1E page 62" + }, + { + "template": "90.1-2010", + "minimum_capacity": 225000, + "maximum_capacity": 249999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": null, + "minimum_thermal_efficiency": 0.8, + "minimum_combustion_efficiency": null, + "annotation": "Table 6.8.1E page 62" + }, + { + "template": "90.1-2013", + "minimum_capacity": 0, + "maximum_capacity": 224999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": 0.78, + "minimum_thermal_efficiency": 0.8, + "minimum_combustion_efficiency": null, + "annotation": "Table 6.8.1E page 72" + }, + { + "template": "90.1-2013", + "minimum_capacity": 225000, + "maximum_capacity": 249999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": null, + "minimum_thermal_efficiency": 0.8, + "minimum_combustion_efficiency": null, + "annotation": "Table 6.8.1E page 72" + }, + { + "template": "90.1-2016", + "minimum_capacity": 0, + "maximum_capacity": 224999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": 0.78, + "minimum_thermal_efficiency": 0.8, + "minimum_combustion_efficiency": null, + "annotation": "Table 6.8.1E page 116" + }, + { + "template": "90.1-2016", + "minimum_capacity": 225000, + "maximum_capacity": 249999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": null, + "minimum_thermal_efficiency": 0.8, + "minimum_combustion_efficiency": null, + "annotation": "Table 6.8.1E page 116" + }, + { + "template": "90.1-2019", + "minimum_capacity": 0, + "maximum_capacity": 224999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": null, + "minimum_thermal_efficiency": 0.81, + "minimum_combustion_efficiency": null, + "annotation": "Table 6.8.1-6 for > 225 ktbu/hr; Table F-4 for < 225 ktbu/hr" + }, + { + "template": "90.1-2019", + "minimum_capacity": 225000, + "maximum_capacity": 249999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_annual_fuel_utilization_efficiency": null, + "minimum_thermal_efficiency": 0.8, + "minimum_combustion_efficiency": null, + "annotation": "Table 6.8.1-6 for > 225 ktbu/hr; Table F-4 for < 225 ktbu/hr" + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_pump_cooling_90_1.json b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_pump_cooling_90_1.json new file mode 100644 index 0000000000..d3d98dd0ac --- /dev/null +++ b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_pump_cooling_90_1.json @@ -0,0 +1,3610 @@ +[ + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "PTHP", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": 12.3, + "pthp_eer_coefficient_2": 0.213, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1D" + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "PTHP", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": 12.3, + "pthp_eer_coefficient_2": 0.213, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1D" + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "PTHP", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": 12.3, + "pthp_eer_coefficient_2": 0.213, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2007 Table 6.8.1D" + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "PTHP", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": 12.3, + "pthp_eer_coefficient_2": 0.213, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2007 Table 6.8.1D" + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "PTHP", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": 12.3, + "pthp_eer_coefficient_2": 0.213, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1D Before 10/8/2012" + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "PTHP", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": 12.3, + "pthp_eer_coefficient_2": 0.213, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1D Before 10/8/2012" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "PTHP", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": 14, + "pthp_eer_coefficient_2": 0.3, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2013 Table 6.8.1-4" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "PTHP", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": 14, + "pthp_eer_coefficient_2": 0.3, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2013 Table 6.8.1-4" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "PTHP", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": 14, + "pthp_eer_coefficient_2": 0.3, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2013 Table 6.8.1-4" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "PTHP", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": 14, + "pthp_eer_coefficient_2": 0.3, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2013 Table 6.8.1-4" + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 9.7, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006" + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 9.7, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006" + }, + { + "template": "90.1-2004", + "cooling_type": "ThroughWall", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 9.7, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006" + }, + { + "template": "90.1-2004", + "cooling_type": "ThroughWall", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 9.7, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006" + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.1, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1B" + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.9, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1B" + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.3, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1B" + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.1, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1B" + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9, + "minimum_iplv": 9.2, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1B" + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 8.8, + "minimum_iplv": 9, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1B" + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 13, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2007 Table 6.8.1B, As of 1/23/2006" + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 13, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2007 Table 6.8.1B, As of 1/23/2006" + }, + { + "template": "90.1-2007", + "cooling_type": "ThroughWall", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 10.6, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2007 Table 6.8.1B, As of 1/23/2006" + }, + { + "template": "90.1-2007", + "cooling_type": "ThroughWall", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 10.6, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2007 Table 6.8.1B, As of 1/23/2006" + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.1, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2007 Table 6.8.1B, Before 1/1/2010" + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.9, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2007 Table 6.8.1B, Before 1/1/2010" + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.3, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2007 Table 6.8.1B, Before 1/1/2010" + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.1, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2007 Table 6.8.1B, Before 1/1/2010" + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9, + "minimum_iplv": 9.2, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2007 Table 6.8.1B, Before 1/1/2010" + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 8.8, + "minimum_iplv": 9, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2007 Table 6.8.1B, Before 1/1/2010" + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 13, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 13, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2010", + "cooling_type": "ThroughWall", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 12, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2010", + "cooling_type": "ThroughWall", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 12, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 11, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 11.2, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.8, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 11, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.6, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 10.7, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.4, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 10.5, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.5, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 9.6, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.3, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 9.4, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_seasonal_efficiency": 13, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2015" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_seasonal_efficiency": 13, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2015" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 14, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2015" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 14, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2015" + }, + { + "template": "90.1-2013", + "cooling_type": "ThroughWall", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 12, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2" + }, + { + "template": "90.1-2013", + "cooling_type": "ThroughWall", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 12, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 11, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 11.2, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 11, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 12.2, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.8, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 11, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.8, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 12, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.6, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 10.7, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.6, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 11.6, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.4, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 10.5, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.4, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 11.4, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.5, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 9.6, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.5, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 10.6, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.3, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 9.4, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.3, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 0.4, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016" + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 10, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006" + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 10, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006" + }, + { + "template": "90.1-2004", + "cooling_type": "ThroughWall", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 10, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006" + }, + { + "template": "90.1-2004", + "cooling_type": "ThroughWall", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 10, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006" + }, + { + "template": "90.1-2004", + "cooling_type": "SmallDuctHighVelocity", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 10, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1B" + }, + { + "template": "90.1-2004", + "cooling_type": "SmallDuctHighVelocity", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 10, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1B" + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.1, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1B" + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.9, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1B" + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.3, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1B" + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.1, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1B" + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9, + "minimum_iplv": 9.2, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1B" + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 8.8, + "minimum_iplv": 9, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1B" + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 13, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2007 Table 6.8.1B, As of 1/23/2006" + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 13, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2007 Table 6.8.1B, As of 1/23/2006" + }, + { + "template": "90.1-2007", + "cooling_type": "ThroughWall", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 10.9, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2007 Table 6.8.1B, As of 1/23/2006" + }, + { + "template": "90.1-2007", + "cooling_type": "ThroughWall", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 10.9, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2007 Table 6.8.1B, As of 1/23/2006" + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.1, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2007 Table 6.8.1B, Before 1/1/2010" + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.9, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2007 Table 6.8.1B, Before 1/1/2010" + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.3, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2007 Table 6.8.1B, Before 1/1/2010" + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.1, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2007 Table 6.8.1B, Before 1/1/2010" + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9, + "minimum_iplv": 9.2, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2007 Table 6.8.1B, Before 1/1/2010" + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 8.8, + "minimum_iplv": 9, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2007 Table 6.8.1B, Before 1/1/2010" + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 13, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 13, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2010", + "cooling_type": "ThroughWall", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 12, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2010", + "cooling_type": "ThroughWall", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 12, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 11, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 11.2, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.8, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 11, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.6, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 10.7, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.4, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 10.5, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.5, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 9.6, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.3, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 9.4, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_seasonal_efficiency": 13, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2015" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_seasonal_efficiency": 13, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2015" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 14, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2015" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 14, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2015" + }, + { + "template": "90.1-2013", + "cooling_type": "ThroughWall", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 12, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2" + }, + { + "template": "90.1-2013", + "cooling_type": "ThroughWall", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 12, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2" + }, + { + "template": "90.1-2013", + "cooling_type": "SmallDuctHighVelocity", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 11, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016" + }, + { + "template": "90.1-2013", + "cooling_type": "SmallDuctHighVelocity", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 11, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 11, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 11.2, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 11, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 12.2, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.8, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 11, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.8, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 12, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.6, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 10.7, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.6, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 11.6, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.4, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 10.5, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.4, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 11.4, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.5, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 9.6, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.5, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 10.6, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.3, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 9.4, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.3, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 0.4, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1-2 Before 1/1/2016" + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "PTHP", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": 14, + "pthp_eer_coefficient_2": 0.3, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "PTHP", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": 14, + "pthp_eer_coefficient_2": 0.3, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 14, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 14, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "ThroughWall", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 12, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "ThroughWall", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 12, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 11, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 12.2, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.8, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 12, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.6, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 11.6, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.4, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 11.4, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.5, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 10.6, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.3, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 0.4, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 14, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 14, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "ThroughWall", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 12, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "ThroughWall", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 12, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "SmallDuctHighVelocity", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 11, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "SmallDuctHighVelocity", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 11, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 11, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 12.2, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.8, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 12, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.6, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 11.6, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.4, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 11.4, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.5, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 10.6, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.3, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 0.4, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "PTHP", + "minimum_capacity": 0, + "maximum_capacity": 6999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 11.9, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "PTHP", + "minimum_capacity": 0, + "maximum_capacity": 6999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 11.9, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "PTHP", + "minimum_capacity": 7000, + "maximum_capacity": 14999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": 14, + "pthp_eer_coefficient_2": 0.3, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "PTHP", + "minimum_capacity": 7000, + "maximum_capacity": 14999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": 14, + "pthp_eer_coefficient_2": 0.3, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "PTHP", + "minimum_capacity": 15000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.5, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "PTHP", + "minimum_capacity": 15000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.5, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_seasonal_efficiency": 13, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_seasonal_efficiency": 13, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 14, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 14, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "ThroughWall", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 12, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "ThroughWall", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 12, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 11, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 12.2, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.8, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 12, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.6, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 11.6, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.4, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 11.4, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.5, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 10.6, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.3, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 0.4, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 14, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 14, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "ThroughWall", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 12, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "ThroughWall", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 12, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "SmallDuctHighVelocity", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 11, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "SmallDuctHighVelocity", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 11, + "minimum_full_load_efficiency": null, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": null, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 11, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 12.2, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.8, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 12, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.6, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 11.6, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 10.4, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 11.4, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.5, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 10.6, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_full_load_efficiency": 9.3, + "minimum_iplv": null, + "minimum_integrated_energy_efficiency_ratio": 0.4, + "pthp_eer_coefficient_1": null, + "pthp_eer_coefficient_2": null, + "cool_cap_ft": "HPACCoolCapFT", + "cool_cap_fflow": "HPACCoolCapFFF", + "cool_eir_ft": "HPACCOOLEIRFT", + "cool_eir_fflow": "HPACCOOLEIRFFF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_pump_heating_90_1.json b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_pump_heating_90_1.json new file mode 100644 index 0000000000..b8c3d3a60d --- /dev/null +++ b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_pump_heating_90_1.json @@ -0,0 +1,1002 @@ +[ + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "subcategory": "PTHP", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": null, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": 3.2, + "pthp_cop_coefficient_2": 0.026, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1D" + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "subcategory": "PTHP", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": null, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": 3.2, + "pthp_cop_coefficient_2": 0.026, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": "From 90.1-2007 Table 6.8.1D" + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "subcategory": "PTHP", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": null, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": 3.2, + "pthp_cop_coefficient_2": 0.026, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1D before 10/08/2012" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "subcategory": "PTHP", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": null, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": 3.7, + "pthp_cop_coefficient_2": 0.052, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": "From 90.1-2013 Table 6.8.1-4" + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": 6.6, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006" + }, + { + "template": "90.1-2004", + "cooling_type": "ThroughWall", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": 6.6, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006" + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": null, + "minimum_coefficient_of_performance_heating": 3.2, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006" + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": null, + "minimum_coefficient_of_performance_heating": 3.1, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006" + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": 7.7, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": "From 90.1-2007 Table 6.8.1B, As of 1/23/2006" + }, + { + "template": "90.1-2007", + "cooling_type": "ThroughWall", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": 7, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": "From 90.1-2007 Table 6.8.1B, As of 1/23/2006" + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": null, + "minimum_coefficient_of_performance_heating": 3.2, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": "From 90.1-2007 Table 6.8.1B, Before 1/1/2010" + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": null, + "minimum_coefficient_of_performance_heating": 3.1, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": "From 90.1-2007 Table 6.8.1B, Before 1/1/2010" + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": 7.7, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2010", + "cooling_type": "ThroughWall", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": 7.4, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": null, + "minimum_coefficient_of_performance_heating": 3.3, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": null, + "minimum_coefficient_of_performance_heating": 3.2, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_heating_seasonal_performance_factor": 7.7, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "HPACHeatCapFT", + "heat_cap_fflow": "HPACHeatCapFFF", + "heat_eir_ft": "HPACHeatEIRFT", + "heat_eir_fflow": "HPACHeatEIRFFF", + "heat_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2013 Table 6.8.1-2, Before 1/1/2015" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": 8, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "HPACHeatCapFT", + "heat_cap_fflow": "HPACHeatCapFFF", + "heat_eir_ft": "HPACHeatEIRFT", + "heat_eir_fflow": "HPACHeatEIRFFF", + "heat_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2013 Table 6.8.1-2, Before 1/1/2015" + }, + { + "template": "90.1-2013", + "cooling_type": "ThroughWall", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": 7.4, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": "From 90.1-2013 Table 6.8.1-3" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": null, + "minimum_coefficient_of_performance_heating": 3.3, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "HPACHeatCapFT", + "heat_cap_fflow": "HPACHeatCapFFF", + "heat_eir_ft": "HPACHeatEIRFT", + "heat_eir_fflow": "HPACHeatEIRFFF", + "heat_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2013 Table 6.8.1-5" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": null, + "minimum_coefficient_of_performance_heating": 3.2, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "HPACHeatCapFT", + "heat_cap_fflow": "HPACHeatCapFFF", + "heat_eir_ft": "HPACHeatEIRFT", + "heat_eir_fflow": "HPACHeatEIRFFF", + "heat_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2013 Table 6.8.1-6" + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": 6.8, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006" + }, + { + "template": "90.1-2004", + "cooling_type": "ThroughWall", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": 6.8, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006" + }, + { + "template": "90.1-2004", + "cooling_type": "SmallDuctHighVelocity", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": 6.8, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": "From 90.1-2004 Table 6.8.1B, Before 1/23/2006" + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": 7.7, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": "From 90.1-2007 Table 6.8.1B, As of 1/23/2006" + }, + { + "template": "90.1-2007", + "cooling_type": "ThroughWall", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": 7.1, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": "From 90.1-2007 Table 6.8.1B, As of 1/23/2006" + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": 7.7, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2010", + "cooling_type": "ThroughWall", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": 7.4, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_heating_seasonal_performance_factor": 7.7, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "HPACHeatCapFT", + "heat_cap_fflow": "HPACHeatCapFFF", + "heat_eir_ft": "HPACHeatEIRFT", + "heat_eir_fflow": "HPACHeatEIRFFF", + "heat_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2013 Table 6.8.1-2, Before 1/1/2015" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": 8.2, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "HPACHeatCapFT", + "heat_cap_fflow": "HPACHeatCapFFF", + "heat_eir_ft": "HPACHeatEIRFT", + "heat_eir_fflow": "HPACHeatEIRFFF", + "heat_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "From 90.1-2013 Table 6.8.1-2, Before 1/1/2015" + }, + { + "template": "90.1-2013", + "cooling_type": "ThroughWall", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": 7.4, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": "From 90.1-2013 Table 6.8.1-2" + }, + { + "template": "90.1-2013", + "cooling_type": "SmallDuctHighVelocity", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": 6.8, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": "From 90.1-2013 Table 6.8.1-4" + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "subcategory": "PTHP", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": null, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": 3.7, + "pthp_cop_coefficient_2": 0.052, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": 8, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "HPACHeatCapFT", + "heat_cap_fflow": "HPACHeatCapFFF", + "heat_eir_ft": "HPACHeatEIRFT", + "heat_eir_fflow": "HPACHeatEIRFFF", + "heat_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "ThroughWall", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": 7.4, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": null, + "minimum_coefficient_of_performance_heating": 3.3, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "HPACHeatCapFT", + "heat_cap_fflow": "HPACHeatCapFFF", + "heat_eir_ft": "HPACHeatEIRFT", + "heat_eir_fflow": "HPACHeatEIRFFF", + "heat_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": null, + "minimum_coefficient_of_performance_heating": 3.2, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "HPACHeatCapFT", + "heat_cap_fflow": "HPACHeatCapFFF", + "heat_eir_ft": "HPACHeatEIRFT", + "heat_eir_fflow": "HPACHeatEIRFFF", + "heat_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": 8.2, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "HPACHeatCapFT", + "heat_cap_fflow": "HPACHeatCapFFF", + "heat_eir_ft": "HPACHeatEIRFT", + "heat_eir_fflow": "HPACHeatEIRFFF", + "heat_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "ThroughWall", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": 7.4, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "SmallDuctHighVelocity", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": 6.8, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "subcategory": "PTHP", + "minimum_capacity": 0, + "maximum_capacity": 6999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": null, + "minimum_coefficient_of_performance_heating": 3.3, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "subcategory": "PTHP", + "minimum_capacity": 6999, + "maximum_capacity": 14999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": null, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": 3.7, + "pthp_cop_coefficient_2": 0.052, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "subcategory": "PTHP", + "minimum_capacity": 14999, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": null, + "minimum_coefficient_of_performance_heating": 2.9, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": 8, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "HPACHeatCapFT", + "heat_cap_fflow": "HPACHeatCapFFF", + "heat_eir_ft": "HPACHeatEIRFT", + "heat_eir_fflow": "HPACHeatEIRFFF", + "heat_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "ThroughWall", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": 7.4, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": null, + "minimum_coefficient_of_performance_heating": 3.3, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "HPACHeatCapFT", + "heat_cap_fflow": "HPACHeatCapFFF", + "heat_eir_ft": "HPACHeatEIRFT", + "heat_eir_fflow": "HPACHeatEIRFFF", + "heat_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": null, + "minimum_coefficient_of_performance_heating": 3.2, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "HPACHeatCapFT", + "heat_cap_fflow": "HPACHeatCapFFF", + "heat_eir_ft": "HPACHeatEIRFT", + "heat_eir_fflow": "HPACHeatEIRFFF", + "heat_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": 8.2, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "HPACHeatCapFT", + "heat_cap_fflow": "HPACHeatCapFFF", + "heat_eir_ft": "HPACHeatEIRFT", + "heat_eir_fflow": "HPACHeatEIRFFF", + "heat_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "ThroughWall", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 29999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": 7.4, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "SmallDuctHighVelocity", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_heating_seasonal_performance_factor": 6.8, + "minimum_coefficient_of_performance_heating": null, + "minimum_energy_efficiency_ratio": null, + "pthp_cop_coefficient_1": null, + "pthp_cop_coefficient_2": null, + "heat_cap_ft": "DXHEAT-NECB2011-REF-CAPFT", + "heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW", + "heat_eir_ft": "DXHEAT-NECB2011-REF-EIRFT", + "heat_eir_fflow": "DXHEAT-NECB2011-REF-EIRFFLOW", + "heat_plf_fplr": "DXHEAT-NECB2011-REF-PLFFPLR", + "annotation": null + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_rejection_90_1.json b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_rejection_90_1.json new file mode 100644 index 0000000000..64dce5ae76 --- /dev/null +++ b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_rejection_90_1.json @@ -0,0 +1,272 @@ +[ + { + "template": "90.1-2004", + "equipment_type": "Open Cooling Tower", + "fan_type": "Centrifugal", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 20, + "annotation": "From 90.1-2004 Table 6.8.1G" + }, + { + "template": "90.1-2004", + "equipment_type": "Open Cooling Tower", + "fan_type": "Propeller or Axial", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 38.2, + "annotation": "From 90.1-2004 Table 6.8.1G" + }, + { + "template": "90.1-2004", + "equipment_type": "Closed Cooling Tower", + "fan_type": "Centrifugal", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 20, + "annotation": "From 90.1-2004 Table 6.8.1G" + }, + { + "template": "90.1-2004", + "equipment_type": "Closed Cooling Tower", + "fan_type": "Propeller or Axial", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 38.2, + "annotation": "From 90.1-2004 Table 6.8.1G" + }, + { + "template": "90.1-2004", + "equipment_type": "Dry Cooler", + "fan_type": "Propeller or Axial", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 4, + "annotation": "Not required by code. Value provided by 90.1 Mechanical Subcommittee" + }, + { + "template": "90.1-2007", + "equipment_type": "Open Cooling Tower", + "fan_type": "Centrifugal", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 20, + "annotation": "From 90.1-2007 Table 6.8.1G" + }, + { + "template": "90.1-2007", + "equipment_type": "Open Cooling Tower", + "fan_type": "Propeller or Axial", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 38.2, + "annotation": "From 90.1-2007 Table 6.8.1G" + }, + { + "template": "90.1-2007", + "equipment_type": "Closed Cooling Tower", + "fan_type": "Centrifugal", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 20, + "annotation": "From 90.1-2007 Table 6.8.1G" + }, + { + "template": "90.1-2007", + "equipment_type": "Closed Cooling Tower", + "fan_type": "Propeller or Axial", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 38.2, + "annotation": "From 90.1-2007 Table 6.8.1G" + }, + { + "template": "90.1-2007", + "equipment_type": "Dry Cooler", + "fan_type": "Propeller or Axial", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 4, + "annotation": "Not required by code. Value provided by 90.1 Mechanical Subcommittee" + }, + { + "template": "90.1-2010", + "equipment_type": "Open Cooling Tower", + "fan_type": "Centrifugal", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 20, + "annotation": "From 90.1-2010 Table 6.8.1 G" + }, + { + "template": "90.1-2010", + "equipment_type": "Open Cooling Tower", + "fan_type": "Propeller or Axial", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 38.2, + "annotation": "From 90.1-2010 Table 6.8.1 G" + }, + { + "template": "90.1-2010", + "equipment_type": "Closed Cooling Tower", + "fan_type": "Centrifugal", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 7, + "annotation": "From 90.1-2010 Table 6.8.1 G" + }, + { + "template": "90.1-2010", + "equipment_type": "Closed Cooling Tower", + "fan_type": "Propeller or Axial", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 14, + "annotation": "From 90.1-2010 Table 6.8.1 G" + }, + { + "template": "90.1-2010", + "equipment_type": "Dry Cooler", + "fan_type": "Propeller or Axial", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 4, + "annotation": "Not required by code. Value provided by 90.1 Mechanical Subcommittee" + }, + { + "template": "90.1-2013", + "equipment_type": "Open Cooling Tower", + "fan_type": "Centrifugal", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 20, + "annotation": "From 90.1-2013 Table 6.8.1-7" + }, + { + "template": "90.1-2013", + "equipment_type": "Open Cooling Tower", + "fan_type": "Propeller or Axial", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 40.2, + "annotation": "From 90.1-2013 Table 6.8.1-7" + }, + { + "template": "90.1-2013", + "equipment_type": "Closed Cooling Tower", + "fan_type": "Centrifugal", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 7, + "annotation": "From 90.1-2013 Table 6.8.1-7" + }, + { + "template": "90.1-2013", + "equipment_type": "Closed Cooling Tower", + "fan_type": "Propeller or Axial", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 14, + "annotation": "From 90.1-2013 Table 6.8.1-7" + }, + { + "template": "90.1-2013", + "equipment_type": "Dry Cooler", + "fan_type": "Propeller or Axial", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 4, + "annotation": "NOTE: Not required by code. Value provided by 90.1 Mechanical Subcommittee" + }, + { + "template": "90.1-2016", + "equipment_type": "Open Cooling Tower", + "fan_type": "Centrifugal", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 20, + "annotation": "From 90.1-2016 Table 6.8.1-7" + }, + { + "template": "90.1-2016", + "equipment_type": "Open Cooling Tower", + "fan_type": "Propeller or Axial", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 40.2, + "annotation": "From 90.1-2016 Table 6.8.1-7" + }, + { + "template": "90.1-2016", + "equipment_type": "Closed Cooling Tower", + "fan_type": "Centrifugal", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 7, + "annotation": "From 90.1-2016 Table 6.8.1-7" + }, + { + "template": "90.1-2016", + "equipment_type": "Closed Cooling Tower", + "fan_type": "Propeller or Axial", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 16.1, + "annotation": "From 90.1-2016 Table 6.8.1-7" + }, + { + "template": "90.1-2016", + "equipment_type": "Dry Cooler", + "fan_type": "Propeller or Axial", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 4, + "annotation": "NOTE Not required by code. Value provided by 90.1 Mechanical Subcommittee" + }, + { + "template": "90.1-2019", + "equipment_type": "Open Cooling Tower", + "fan_type": "Centrifugal", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 20, + "annotation": "From 90.1-2019 Table 6.8.1-7" + }, + { + "template": "90.1-2019", + "equipment_type": "Open Cooling Tower", + "fan_type": "Propeller or Axial", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 40.2, + "annotation": "From 90.1-2019 Table 6.8.1-7" + }, + { + "template": "90.1-2019", + "equipment_type": "Closed Cooling Tower", + "fan_type": "Centrifugal", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 7, + "annotation": "From 90.1-2019 Table 6.8.1-7" + }, + { + "template": "90.1-2019", + "equipment_type": "Closed Cooling Tower", + "fan_type": "Propeller or Axial", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 16.1, + "annotation": "From 90.1-2019 Table 6.8.1-7" + }, + { + "template": "90.1-2019", + "equipment_type": "Dry Cooler", + "fan_type": "Propeller or Axial", + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_performance_gpm_per_hp": 4.5, + "annotation": "From 90.1-2019 Table 6.8.1.7. Juan Gonzalez Added 01/11/2021 to account for fluid coolers in data center water loop heat pump condenser loops" + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_motors_90_1.json b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_motors_90_1.json new file mode 100644 index 0000000000..13255b2f2c --- /dev/null +++ b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_motors_90_1.json @@ -0,0 +1,1472 @@ +[ + { + "template": "90.1-2004", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 0, + "maximum_capacity": 0.999, + "nominal_full_load_efficiency": 0.29, + "annotation": "Motors below 1 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" + }, + { + "template": "90.1-2004", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 1, + "maximum_capacity": 1.499, + "nominal_full_load_efficiency": 0.825, + "annotation": "From 90.1-2004 Table 10.8" + }, + { + "template": "90.1-2004", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 1.5, + "maximum_capacity": 1.999, + "nominal_full_load_efficiency": 0.84, + "annotation": "From 90.1-2004 Table 10.8" + }, + { + "template": "90.1-2004", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 2, + "maximum_capacity": 2.999, + "nominal_full_load_efficiency": 0.84, + "annotation": "From 90.1-2004 Table 10.8" + }, + { + "template": "90.1-2004", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 3, + "maximum_capacity": 4.999, + "nominal_full_load_efficiency": 0.875, + "annotation": "From 90.1-2004 Table 10.8" + }, + { + "template": "90.1-2004", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 5, + "maximum_capacity": 7.499, + "nominal_full_load_efficiency": 0.875, + "annotation": "From 90.1-2004 Table 10.8" + }, + { + "template": "90.1-2004", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 7.5, + "maximum_capacity": 9.999, + "nominal_full_load_efficiency": 0.895, + "annotation": "From 90.1-2004 Table 10.8" + }, + { + "template": "90.1-2004", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 10, + "maximum_capacity": 14.999, + "nominal_full_load_efficiency": 0.895, + "annotation": "From 90.1-2004 Table 10.8" + }, + { + "template": "90.1-2004", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 15, + "maximum_capacity": 19.999, + "nominal_full_load_efficiency": 0.91, + "annotation": "From 90.1-2004 Table 10.8" + }, + { + "template": "90.1-2004", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 20, + "maximum_capacity": 24.999, + "nominal_full_load_efficiency": 0.91, + "annotation": "From 90.1-2004 Table 10.8" + }, + { + "template": "90.1-2004", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 25, + "maximum_capacity": 29.999, + "nominal_full_load_efficiency": 0.924, + "annotation": "From 90.1-2004 Table 10.8" + }, + { + "template": "90.1-2004", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 30, + "maximum_capacity": 39.999, + "nominal_full_load_efficiency": 0.924, + "annotation": "From 90.1-2004 Table 10.8" + }, + { + "template": "90.1-2004", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 40, + "maximum_capacity": 49.999, + "nominal_full_load_efficiency": 0.93, + "annotation": "From 90.1-2004 Table 10.8" + }, + { + "template": "90.1-2004", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 50, + "maximum_capacity": 59.999, + "nominal_full_load_efficiency": 0.93, + "annotation": "From 90.1-2004 Table 10.8" + }, + { + "template": "90.1-2004", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 60, + "maximum_capacity": 74.999, + "nominal_full_load_efficiency": 0.936, + "annotation": "From 90.1-2004 Table 10.8" + }, + { + "template": "90.1-2004", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 75, + "maximum_capacity": 99.999, + "nominal_full_load_efficiency": 0.941, + "annotation": "From 90.1-2004 Table 10.8" + }, + { + "template": "90.1-2004", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 100, + "maximum_capacity": 124.999, + "nominal_full_load_efficiency": 0.945, + "annotation": "From 90.1-2004 Table 10.8" + }, + { + "template": "90.1-2004", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 125, + "maximum_capacity": 149.999, + "nominal_full_load_efficiency": 0.945, + "annotation": "From 90.1-2004 Table 10.8" + }, + { + "template": "90.1-2004", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 150, + "maximum_capacity": 199.999, + "nominal_full_load_efficiency": 0.95, + "annotation": "From 90.1-2004 Table 10.8" + }, + { + "template": "90.1-2004", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 200, + "maximum_capacity": 9999, + "nominal_full_load_efficiency": 0.95, + "annotation": "From 90.1-2004 Table 10.8" + }, + { + "template": "90.1-2007", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 0, + "maximum_capacity": 0.999, + "nominal_full_load_efficiency": 0.29, + "annotation": "Motors below 1 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" + }, + { + "template": "90.1-2007", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 1, + "maximum_capacity": 1.499, + "nominal_full_load_efficiency": 0.825, + "annotation": "From 90.1-2007 Table 10.8" + }, + { + "template": "90.1-2007", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 1.5, + "maximum_capacity": 1.999, + "nominal_full_load_efficiency": 0.84, + "annotation": "From 90.1-2007 Table 10.8" + }, + { + "template": "90.1-2007", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 2, + "maximum_capacity": 2.999, + "nominal_full_load_efficiency": 0.84, + "annotation": "From 90.1-2007 Table 10.8" + }, + { + "template": "90.1-2007", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 3, + "maximum_capacity": 4.999, + "nominal_full_load_efficiency": 0.875, + "annotation": "From 90.1-2007 Table 10.8" + }, + { + "template": "90.1-2007", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 5, + "maximum_capacity": 7.499, + "nominal_full_load_efficiency": 0.875, + "annotation": "From 90.1-2007 Table 10.8" + }, + { + "template": "90.1-2007", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 7.5, + "maximum_capacity": 9.999, + "nominal_full_load_efficiency": 0.895, + "annotation": "From 90.1-2007 Table 10.8" + }, + { + "template": "90.1-2007", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 10, + "maximum_capacity": 14.999, + "nominal_full_load_efficiency": 0.895, + "annotation": "From 90.1-2007 Table 10.8" + }, + { + "template": "90.1-2007", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 15, + "maximum_capacity": 19.999, + "nominal_full_load_efficiency": 0.91, + "annotation": "From 90.1-2007 Table 10.8" + }, + { + "template": "90.1-2007", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 20, + "maximum_capacity": 24.999, + "nominal_full_load_efficiency": 0.91, + "annotation": "From 90.1-2007 Table 10.8" + }, + { + "template": "90.1-2007", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 25, + "maximum_capacity": 29.999, + "nominal_full_load_efficiency": 0.924, + "annotation": "From 90.1-2007 Table 10.8" + }, + { + "template": "90.1-2007", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 30, + "maximum_capacity": 39.999, + "nominal_full_load_efficiency": 0.924, + "annotation": "From 90.1-2007 Table 10.8" + }, + { + "template": "90.1-2007", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 40, + "maximum_capacity": 49.999, + "nominal_full_load_efficiency": 0.93, + "annotation": "From 90.1-2007 Table 10.8" + }, + { + "template": "90.1-2007", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 50, + "maximum_capacity": 59.999, + "nominal_full_load_efficiency": 0.93, + "annotation": "From 90.1-2007 Table 10.8" + }, + { + "template": "90.1-2007", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 60, + "maximum_capacity": 74.999, + "nominal_full_load_efficiency": 0.936, + "annotation": "From 90.1-2007 Table 10.8" + }, + { + "template": "90.1-2007", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 75, + "maximum_capacity": 99.999, + "nominal_full_load_efficiency": 0.941, + "annotation": "From 90.1-2007 Table 10.8" + }, + { + "template": "90.1-2007", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 100, + "maximum_capacity": 124.999, + "nominal_full_load_efficiency": 0.945, + "annotation": "From 90.1-2007 Table 10.8" + }, + { + "template": "90.1-2007", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 125, + "maximum_capacity": 149.999, + "nominal_full_load_efficiency": 0.945, + "annotation": "From 90.1-2007 Table 10.8" + }, + { + "template": "90.1-2007", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 150, + "maximum_capacity": 199.999, + "nominal_full_load_efficiency": 0.95, + "annotation": "From 90.1-2007 Table 10.8" + }, + { + "template": "90.1-2007", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 200, + "maximum_capacity": 9999, + "nominal_full_load_efficiency": 0.95, + "annotation": "From 90.1-2007 Table 10.8" + }, + { + "template": "90.1-2010", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 0, + "maximum_capacity": 0.999, + "nominal_full_load_efficiency": 0.29, + "annotation": "Motors below 1 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" + }, + { + "template": "90.1-2010", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 1, + "maximum_capacity": 1.499, + "nominal_full_load_efficiency": 0.855, + "annotation": "From 90.1-2010 Table 10.8B" + }, + { + "template": "90.1-2010", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 1.5, + "maximum_capacity": 1.999, + "nominal_full_load_efficiency": 0.865, + "annotation": "From 90.1-2010 Table 10.8B" + }, + { + "template": "90.1-2010", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 2, + "maximum_capacity": 2.999, + "nominal_full_load_efficiency": 0.865, + "annotation": "From 90.1-2010 Table 10.8B" + }, + { + "template": "90.1-2010", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 3, + "maximum_capacity": 4.999, + "nominal_full_load_efficiency": 0.895, + "annotation": "From 90.1-2010 Table 10.8B" + }, + { + "template": "90.1-2010", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 5, + "maximum_capacity": 7.499, + "nominal_full_load_efficiency": 0.895, + "annotation": "From 90.1-2010 Table 10.8B" + }, + { + "template": "90.1-2010", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 7.5, + "maximum_capacity": 9.999, + "nominal_full_load_efficiency": 0.917, + "annotation": "From 90.1-2010 Table 10.8B" + }, + { + "template": "90.1-2010", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 10, + "maximum_capacity": 14.999, + "nominal_full_load_efficiency": 0.917, + "annotation": "From 90.1-2010 Table 10.8B" + }, + { + "template": "90.1-2010", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 15, + "maximum_capacity": 19.999, + "nominal_full_load_efficiency": 0.924, + "annotation": "From 90.1-2010 Table 10.8B" + }, + { + "template": "90.1-2010", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 20, + "maximum_capacity": 24.9999, + "nominal_full_load_efficiency": 0.93, + "annotation": "From 90.1-2010 Table 10.8B" + }, + { + "template": "90.1-2010", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 25, + "maximum_capacity": 29.999, + "nominal_full_load_efficiency": 0.936, + "annotation": "From 90.1-2010 Table 10.8B" + }, + { + "template": "90.1-2010", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 30, + "maximum_capacity": 39.999, + "nominal_full_load_efficiency": 0.936, + "annotation": "From 90.1-2010 Table 10.8B" + }, + { + "template": "90.1-2010", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 40, + "maximum_capacity": 49.999, + "nominal_full_load_efficiency": 0.941, + "annotation": "From 90.1-2010 Table 10.8B" + }, + { + "template": "90.1-2010", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 50, + "maximum_capacity": 59.999, + "nominal_full_load_efficiency": 0.945, + "annotation": "From 90.1-2010 Table 10.8B" + }, + { + "template": "90.1-2010", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 60, + "maximum_capacity": 74.999, + "nominal_full_load_efficiency": 0.95, + "annotation": "From 90.1-2010 Table 10.8B" + }, + { + "template": "90.1-2010", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 75, + "maximum_capacity": 99.999, + "nominal_full_load_efficiency": 0.954, + "annotation": "From 90.1-2010 Table 10.8B" + }, + { + "template": "90.1-2010", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 100, + "maximum_capacity": 124.999, + "nominal_full_load_efficiency": 0.954, + "annotation": "From 90.1-2010 Table 10.8B" + }, + { + "template": "90.1-2010", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 125, + "maximum_capacity": 149.999, + "nominal_full_load_efficiency": 0.954, + "annotation": "From 90.1-2010 Table 10.8B" + }, + { + "template": "90.1-2010", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 150, + "maximum_capacity": 199.999, + "nominal_full_load_efficiency": 0.958, + "annotation": "From 90.1-2010 Table 10.8B" + }, + { + "template": "90.1-2010", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 200, + "maximum_capacity": 249.999, + "nominal_full_load_efficiency": 0.962, + "annotation": "From 90.1-2010 Table 10.8B" + }, + { + "template": "90.1-2010", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 250, + "maximum_capacity": 299.999, + "nominal_full_load_efficiency": 0.962, + "annotation": "From 90.1-2010 Table 10.8B" + }, + { + "template": "90.1-2010", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 300, + "maximum_capacity": 349.999, + "nominal_full_load_efficiency": 0.962, + "annotation": "From 90.1-2010 Table 10.8B" + }, + { + "template": "90.1-2010", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 350, + "maximum_capacity": 399.999, + "nominal_full_load_efficiency": 0.962, + "annotation": "From 90.1-2010 Table 10.8B" + }, + { + "template": "90.1-2010", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 400, + "maximum_capacity": 449.999, + "nominal_full_load_efficiency": 0.962, + "annotation": "From 90.1-2010 Table 10.8B" + }, + { + "template": "90.1-2010", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 450, + "maximum_capacity": 499.999, + "nominal_full_load_efficiency": 0.962, + "annotation": "From 90.1-2010 Table 10.8B" + }, + { + "template": "90.1-2010", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 500, + "maximum_capacity": 9999, + "nominal_full_load_efficiency": 0.962, + "annotation": "From 90.1-2010 Table 10.8B" + }, + { + "template": "90.1-2013", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 0, + "maximum_capacity": 0.08333, + "nominal_full_load_efficiency": 0.29, + "annotation": "Motors below 1/12 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" + }, + { + "template": "90.1-2013", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 0.08334, + "maximum_capacity": 0.999, + "nominal_full_load_efficiency": 0.7, + "annotation": "Motors between 1/12 and 1 HP must be EC, with minimum efficiency of 70% per PNNL" + }, + { + "template": "90.1-2013", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 1, + "maximum_capacity": 1.499, + "nominal_full_load_efficiency": 0.855, + "annotation": null + }, + { + "template": "90.1-2013", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 1.5, + "maximum_capacity": 1.999, + "nominal_full_load_efficiency": 0.865, + "annotation": null + }, + { + "template": "90.1-2013", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 2, + "maximum_capacity": 2.999, + "nominal_full_load_efficiency": 0.865, + "annotation": null + }, + { + "template": "90.1-2013", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 3, + "maximum_capacity": 4.999, + "nominal_full_load_efficiency": 0.895, + "annotation": null + }, + { + "template": "90.1-2013", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 5, + "maximum_capacity": 7.499, + "nominal_full_load_efficiency": 0.895, + "annotation": null + }, + { + "template": "90.1-2013", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 7.5, + "maximum_capacity": 9.999, + "nominal_full_load_efficiency": 0.917, + "annotation": null + }, + { + "template": "90.1-2013", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 10, + "maximum_capacity": 14.999, + "nominal_full_load_efficiency": 0.917, + "annotation": null + }, + { + "template": "90.1-2013", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 15, + "maximum_capacity": 19.999, + "nominal_full_load_efficiency": 0.924, + "annotation": null + }, + { + "template": "90.1-2013", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 20, + "maximum_capacity": 24.999, + "nominal_full_load_efficiency": 0.93, + "annotation": null + }, + { + "template": "90.1-2013", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 25, + "maximum_capacity": 29.999, + "nominal_full_load_efficiency": 0.936, + "annotation": null + }, + { + "template": "90.1-2013", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 30, + "maximum_capacity": 39.999, + "nominal_full_load_efficiency": 0.936, + "annotation": null + }, + { + "template": "90.1-2013", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 40, + "maximum_capacity": 49.999, + "nominal_full_load_efficiency": 0.941, + "annotation": null + }, + { + "template": "90.1-2013", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 50, + "maximum_capacity": 59.999, + "nominal_full_load_efficiency": 0.945, + "annotation": null + }, + { + "template": "90.1-2013", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 60, + "maximum_capacity": 74.999, + "nominal_full_load_efficiency": 0.95, + "annotation": null + }, + { + "template": "90.1-2013", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 75, + "maximum_capacity": 99.999, + "nominal_full_load_efficiency": 0.954, + "annotation": null + }, + { + "template": "90.1-2013", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 100, + "maximum_capacity": 124.999, + "nominal_full_load_efficiency": 0.954, + "annotation": null + }, + { + "template": "90.1-2013", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 125, + "maximum_capacity": 149.999, + "nominal_full_load_efficiency": 0.954, + "annotation": null + }, + { + "template": "90.1-2013", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 150, + "maximum_capacity": 199.999, + "nominal_full_load_efficiency": 0.958, + "annotation": null + }, + { + "template": "90.1-2013", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 200, + "maximum_capacity": 249.999, + "nominal_full_load_efficiency": 0.962, + "annotation": null + }, + { + "template": "90.1-2013", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 250, + "maximum_capacity": 299.999, + "nominal_full_load_efficiency": 0.95, + "annotation": null + }, + { + "template": "90.1-2013", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 300, + "maximum_capacity": 349.999, + "nominal_full_load_efficiency": 0.954, + "annotation": null + }, + { + "template": "90.1-2013", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 350, + "maximum_capacity": 399.999, + "nominal_full_load_efficiency": 0.954, + "annotation": null + }, + { + "template": "90.1-2013", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 400, + "maximum_capacity": 449.999, + "nominal_full_load_efficiency": 0.954, + "annotation": null + }, + { + "template": "90.1-2013", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 450, + "maximum_capacity": 499.999, + "nominal_full_load_efficiency": 0.954, + "annotation": null + }, + { + "template": "90.1-2013", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 500, + "maximum_capacity": 9999, + "nominal_full_load_efficiency": 0.954, + "annotation": null + }, + { + "template": "90.1-2016", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 0, + "maximum_capacity": 0.08333, + "nominal_full_load_efficiency": 0.29, + "annotation": "Motors below 1/12 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" + }, + { + "template": "90.1-2016", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 0.08334, + "maximum_capacity": 0.999, + "nominal_full_load_efficiency": 0.7, + "annotation": "Motors between 1/12 and 1 HP must be EC, with minimum efficiency of 70% per PNNL" + }, + { + "template": "90.1-2016", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 1, + "maximum_capacity": 1.499, + "nominal_full_load_efficiency": 0.855, + "annotation": null + }, + { + "template": "90.1-2016", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 1.5, + "maximum_capacity": 1.999, + "nominal_full_load_efficiency": 0.865, + "annotation": null + }, + { + "template": "90.1-2016", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 2, + "maximum_capacity": 2.999, + "nominal_full_load_efficiency": 0.865, + "annotation": null + }, + { + "template": "90.1-2016", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 3, + "maximum_capacity": 4.999, + "nominal_full_load_efficiency": 0.895, + "annotation": null + }, + { + "template": "90.1-2016", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 5, + "maximum_capacity": 7.499, + "nominal_full_load_efficiency": 0.895, + "annotation": null + }, + { + "template": "90.1-2016", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 7.5, + "maximum_capacity": 9.999, + "nominal_full_load_efficiency": 0.917, + "annotation": null + }, + { + "template": "90.1-2016", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 10, + "maximum_capacity": 14.999, + "nominal_full_load_efficiency": 0.917, + "annotation": null + }, + { + "template": "90.1-2016", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 15, + "maximum_capacity": 19.999, + "nominal_full_load_efficiency": 0.924, + "annotation": null + }, + { + "template": "90.1-2016", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 20, + "maximum_capacity": 24.999, + "nominal_full_load_efficiency": 0.93, + "annotation": null + }, + { + "template": "90.1-2016", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 25, + "maximum_capacity": 29.999, + "nominal_full_load_efficiency": 0.936, + "annotation": null + }, + { + "template": "90.1-2016", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 30, + "maximum_capacity": 39.999, + "nominal_full_load_efficiency": 0.936, + "annotation": null + }, + { + "template": "90.1-2016", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 40, + "maximum_capacity": 49.999, + "nominal_full_load_efficiency": 0.941, + "annotation": null + }, + { + "template": "90.1-2016", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 50, + "maximum_capacity": 59.999, + "nominal_full_load_efficiency": 0.945, + "annotation": null + }, + { + "template": "90.1-2016", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 60, + "maximum_capacity": 74.999, + "nominal_full_load_efficiency": 0.95, + "annotation": null + }, + { + "template": "90.1-2016", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 75, + "maximum_capacity": 99.999, + "nominal_full_load_efficiency": 0.954, + "annotation": null + }, + { + "template": "90.1-2016", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 100, + "maximum_capacity": 124.999, + "nominal_full_load_efficiency": 0.954, + "annotation": null + }, + { + "template": "90.1-2016", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 125, + "maximum_capacity": 149.999, + "nominal_full_load_efficiency": 0.954, + "annotation": null + }, + { + "template": "90.1-2016", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 150, + "maximum_capacity": 199.999, + "nominal_full_load_efficiency": 0.958, + "annotation": null + }, + { + "template": "90.1-2016", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 200, + "maximum_capacity": 249.999, + "nominal_full_load_efficiency": 0.962, + "annotation": null + }, + { + "template": "90.1-2016", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 250, + "maximum_capacity": 299.999, + "nominal_full_load_efficiency": 0.962, + "annotation": null + }, + { + "template": "90.1-2016", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 300, + "maximum_capacity": 349.999, + "nominal_full_load_efficiency": 0.962, + "annotation": null + }, + { + "template": "90.1-2016", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 350, + "maximum_capacity": 399.999, + "nominal_full_load_efficiency": 0.962, + "annotation": null + }, + { + "template": "90.1-2016", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 400, + "maximum_capacity": 449.999, + "nominal_full_load_efficiency": 0.962, + "annotation": null + }, + { + "template": "90.1-2016", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 450, + "maximum_capacity": 499.999, + "nominal_full_load_efficiency": 0.962, + "annotation": null + }, + { + "template": "90.1-2016", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 500, + "maximum_capacity": 9999, + "nominal_full_load_efficiency": 0.962, + "annotation": null + }, + { + "template": "90.1-2019", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 0, + "maximum_capacity": 0.08333, + "nominal_full_load_efficiency": 0.29, + "annotation": "Motors below 1/12 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" + }, + { + "template": "90.1-2019", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 0.08334, + "maximum_capacity": 0.999, + "nominal_full_load_efficiency": 0.7, + "annotation": "Motors between 1/12 and 1 HP must be EC, with minimum efficiency of 70% per PNNL" + }, + { + "template": "90.1-2019", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 1, + "maximum_capacity": 1.499, + "nominal_full_load_efficiency": 0.855, + "annotation": null + }, + { + "template": "90.1-2019", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 1.5, + "maximum_capacity": 1.999, + "nominal_full_load_efficiency": 0.865, + "annotation": null + }, + { + "template": "90.1-2019", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 2, + "maximum_capacity": 2.999, + "nominal_full_load_efficiency": 0.865, + "annotation": null + }, + { + "template": "90.1-2019", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 3, + "maximum_capacity": 4.999, + "nominal_full_load_efficiency": 0.895, + "annotation": null + }, + { + "template": "90.1-2019", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 5, + "maximum_capacity": 7.499, + "nominal_full_load_efficiency": 0.895, + "annotation": null + }, + { + "template": "90.1-2019", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 7.5, + "maximum_capacity": 9.999, + "nominal_full_load_efficiency": 0.917, + "annotation": null + }, + { + "template": "90.1-2019", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 10, + "maximum_capacity": 14.999, + "nominal_full_load_efficiency": 0.917, + "annotation": null + }, + { + "template": "90.1-2019", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 15, + "maximum_capacity": 19.999, + "nominal_full_load_efficiency": 0.924, + "annotation": null + }, + { + "template": "90.1-2019", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 20, + "maximum_capacity": 24.999, + "nominal_full_load_efficiency": 0.93, + "annotation": null + }, + { + "template": "90.1-2019", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 25, + "maximum_capacity": 29.999, + "nominal_full_load_efficiency": 0.936, + "annotation": null + }, + { + "template": "90.1-2019", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 30, + "maximum_capacity": 39.999, + "nominal_full_load_efficiency": 0.936, + "annotation": null + }, + { + "template": "90.1-2019", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 40, + "maximum_capacity": 49.999, + "nominal_full_load_efficiency": 0.941, + "annotation": null + }, + { + "template": "90.1-2019", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 50, + "maximum_capacity": 59.999, + "nominal_full_load_efficiency": 0.945, + "annotation": null + }, + { + "template": "90.1-2019", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 60, + "maximum_capacity": 74.999, + "nominal_full_load_efficiency": 0.95, + "annotation": null + }, + { + "template": "90.1-2019", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 75, + "maximum_capacity": 99.999, + "nominal_full_load_efficiency": 0.954, + "annotation": null + }, + { + "template": "90.1-2019", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 100, + "maximum_capacity": 124.999, + "nominal_full_load_efficiency": 0.954, + "annotation": null + }, + { + "template": "90.1-2019", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 125, + "maximum_capacity": 149.999, + "nominal_full_load_efficiency": 0.954, + "annotation": null + }, + { + "template": "90.1-2019", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 150, + "maximum_capacity": 199.999, + "nominal_full_load_efficiency": 0.958, + "annotation": null + }, + { + "template": "90.1-2019", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 200, + "maximum_capacity": 249.999, + "nominal_full_load_efficiency": 0.962, + "annotation": null + }, + { + "template": "90.1-2019", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 250, + "maximum_capacity": 299.999, + "nominal_full_load_efficiency": 0.962, + "annotation": null + }, + { + "template": "90.1-2019", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 300, + "maximum_capacity": 349.999, + "nominal_full_load_efficiency": 0.962, + "annotation": null + }, + { + "template": "90.1-2019", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 350, + "maximum_capacity": 399.999, + "nominal_full_load_efficiency": 0.962, + "annotation": null + }, + { + "template": "90.1-2019", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 400, + "maximum_capacity": 449.999, + "nominal_full_load_efficiency": 0.962, + "annotation": null + }, + { + "template": "90.1-2019", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 450, + "maximum_capacity": 499.999, + "nominal_full_load_efficiency": 0.962, + "annotation": null + }, + { + "template": "90.1-2019", + "number_of_poles": 4, + "type": "Enclosed", + "synchronous_speed": 1800, + "minimum_capacity": 500, + "maximum_capacity": 9999, + "nominal_full_load_efficiency": 0.962, + "annotation": null + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_unitary_air_conditioners_90_1.json b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_unitary_air_conditioners_90_1.json new file mode 100644 index 0000000000..1bd7fd9e4d --- /dev/null +++ b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_unitary_air_conditioners_90_1.json @@ -0,0 +1,4487 @@ +[ + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "PTAC", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": 12.5, + "ptac_eer_coefficient_2": 0.213, + "minimum_scop": null, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 9.7, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 10.1, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.5, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 240000, + "maximum_capacity": 759999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.3, + "minimum_integrated_part_load_value": 9.5, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 760000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9, + "minimum_integrated_part_load_value": 9.2, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 10, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 10.1, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.5, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 240000, + "maximum_capacity": 759999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.3, + "minimum_integrated_part_load_value": 9.5, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 760000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9, + "minimum_integrated_part_load_value": 9.2, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "CRAC", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.2, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "2004 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "CRAC", + "minimum_capacity": 65000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.1, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "2004 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "CRAC", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 1.9, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "2004 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "PTAC", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": 12.5, + "ptac_eer_coefficient_2": 0.213, + "minimum_scop": null, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 9.7, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 10.3, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.7, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 240000, + "maximum_capacity": 759999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.5, + "minimum_integrated_part_load_value": 9.7, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 760000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.2, + "minimum_integrated_part_load_value": 9.4, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 10, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 10.3, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.7, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 240000, + "maximum_capacity": 759999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.5, + "minimum_integrated_part_load_value": 9.7, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 760000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.2, + "minimum_integrated_part_load_value": 9.4, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2004", + "cooling_type": "WaterCooled", + "heating_type": "All Other", + "subcategory": "CRAC", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.6, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "2004 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" + }, + { + "template": "90.1-2004", + "cooling_type": "WaterCooled", + "heating_type": "All Other", + "subcategory": "CRAC", + "minimum_capacity": 65000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.5, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "2004 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" + }, + { + "template": "90.1-2004", + "cooling_type": "WaterCooled", + "heating_type": "All Other", + "subcategory": "CRAC", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.4, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "2004 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "PTAC", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": 12.5, + "ptac_eer_coefficient_2": 0.213, + "minimum_scop": null, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 13, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 10.1, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.5, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 240000, + "maximum_capacity": 759999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.3, + "minimum_integrated_part_load_value": 9.5, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 760000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9, + "minimum_integrated_part_load_value": 9.2, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 13, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 10.1, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.5, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 240000, + "maximum_capacity": 759999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.3, + "minimum_integrated_part_load_value": 9.5, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 760000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9, + "minimum_integrated_part_load_value": 9.2, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "CRAC", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.2, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "2007 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "CRAC", + "minimum_capacity": 65000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.1, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "2007 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "CRAC", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 1.9, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "2007 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "PTAC", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": 12.5, + "ptac_eer_coefficient_2": 0.213, + "minimum_scop": null, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 13, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 10.3, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.7, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 240000, + "maximum_capacity": 759999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.5, + "minimum_integrated_part_load_value": 9.7, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 760000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.2, + "minimum_integrated_part_load_value": 9.4, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 13, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 10.3, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.7, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 240000, + "maximum_capacity": 759999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.5, + "minimum_integrated_part_load_value": 9.7, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2007", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 760000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.2, + "minimum_integrated_part_load_value": 9.4, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI", + "cool_cap_fflow": "CoilClgDXSnglQRatio_fCFMRatio", + "cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI", + "cool_eir_fflow": "CoilClgDXSnglEIRRatio_fCFMRatio", + "cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac", + "annotation": null + }, + { + "template": "90.1-2007", + "cooling_type": "WaterCooled", + "heating_type": "All Other", + "subcategory": "CRAC", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.6, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "2007 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" + }, + { + "template": "90.1-2007", + "cooling_type": "WaterCooled", + "heating_type": "All Other", + "subcategory": "CRAC", + "minimum_capacity": 65000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.5, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "2007 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" + }, + { + "template": "90.1-2007", + "cooling_type": "WaterCooled", + "heating_type": "All Other", + "subcategory": "CRAC", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.4, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "2007 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "PTAC", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": 13.8, + "ptac_eer_coefficient_2": 0.3, + "minimum_scop": null, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 13, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 10.8, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT", + "cool_cap_fflow": "AHU-1_CoolCStandard10Ton_CapFF", + "cool_eir_ft": "PSZ-AC_CoolCStandard10Ton_EIRFT", + "cool_eir_fflow": "CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF", + "cool_plf_fplr": "PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR", + "annotation": null + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 240000, + "maximum_capacity": 759999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.8, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 9.7, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT", + "cool_cap_fflow": "AHU-1_CoolCStandard10Ton_CapFF", + "cool_eir_ft": "PSZ-AC_CoolCStandard10Ton_EIRFT", + "cool_eir_fflow": "CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF", + "cool_plf_fplr": "PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR", + "annotation": null + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 760000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.5, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 9.2, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT", + "cool_cap_fflow": "AHU-1_CoolCStandard10Ton_CapFF", + "cool_eir_ft": "PSZ-AC_CoolCStandard10Ton_EIRFT", + "cool_eir_fflow": "CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF", + "cool_plf_fplr": "PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR", + "annotation": null + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 13, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 10.8, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT", + "cool_cap_fflow": "AHU-1_CoolCStandard10Ton_CapFF", + "cool_eir_ft": "PSZ-AC_CoolCStandard10Ton_EIRFT", + "cool_eir_fflow": "CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF", + "cool_plf_fplr": "PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR", + "annotation": null + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 240000, + "maximum_capacity": 759999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.8, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 9.7, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT", + "cool_cap_fflow": "AHU-1_CoolCStandard10Ton_CapFF", + "cool_eir_ft": "PSZ-AC_CoolCStandard10Ton_EIRFT", + "cool_eir_fflow": "CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF", + "cool_plf_fplr": "PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR", + "annotation": null + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 760000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.5, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 9.2, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT", + "cool_cap_fflow": "AHU-1_CoolCStandard10Ton_CapFF", + "cool_eir_ft": "PSZ-AC_CoolCStandard10Ton_EIRFT", + "cool_eir_fflow": "CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF", + "cool_plf_fplr": "PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR", + "annotation": null + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "CRAC", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.2, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for downflow units" + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "CRAC", + "minimum_capacity": 65000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.1, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for downflow units" + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "CRAC", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 1.9, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for downflow units" + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "PTAC", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": 13.8, + "ptac_eer_coefficient_2": 0.3, + "minimum_scop": null, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 13, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11.2, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT", + "cool_cap_fflow": "AHU-1_CoolCStandard10Ton_CapFF", + "cool_eir_ft": "PSZ-AC_CoolCStandard10Ton_EIRFT", + "cool_eir_fflow": "CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF", + "cool_plf_fplr": "PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR", + "annotation": null + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 240000, + "maximum_capacity": 759999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 10, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 9.7, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT", + "cool_cap_fflow": "AHU-1_CoolCStandard10Ton_CapFF", + "cool_eir_ft": "PSZ-AC_CoolCStandard10Ton_EIRFT", + "cool_eir_fflow": "CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF", + "cool_plf_fplr": "PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR", + "annotation": null + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 760000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.7, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 9.4, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT", + "cool_cap_fflow": "AHU-1_CoolCStandard10Ton_CapFF", + "cool_eir_ft": "PSZ-AC_CoolCStandard10Ton_EIRFT", + "cool_eir_fflow": "CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF", + "cool_plf_fplr": "PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR", + "annotation": null + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 13, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11.2, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT", + "cool_cap_fflow": "AHU-1_CoolCStandard10Ton_CapFF", + "cool_eir_ft": "PSZ-AC_CoolCStandard10Ton_EIRFT", + "cool_eir_fflow": "CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF", + "cool_plf_fplr": "PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR", + "annotation": null + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 240000, + "maximum_capacity": 759999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 10, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 9.7, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT", + "cool_cap_fflow": "AHU-1_CoolCStandard10Ton_CapFF", + "cool_eir_ft": "PSZ-AC_CoolCStandard10Ton_EIRFT", + "cool_eir_fflow": "CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF", + "cool_plf_fplr": "PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR", + "annotation": null + }, + { + "template": "90.1-2010", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 760000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.7, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 9.4, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT", + "cool_cap_fflow": "AHU-1_CoolCStandard10Ton_CapFF", + "cool_eir_ft": "PSZ-AC_CoolCStandard10Ton_EIRFT", + "cool_eir_fflow": "CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF", + "cool_plf_fplr": "PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR", + "annotation": null + }, + { + "template": "90.1-2010", + "cooling_type": "WaterCooled", + "heating_type": "All Other", + "subcategory": "CRAC", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.6, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" + }, + { + "template": "90.1-2010", + "cooling_type": "WaterCooled", + "heating_type": "All Other", + "subcategory": "CRAC", + "minimum_capacity": 65000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.5, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" + }, + { + "template": "90.1-2010", + "cooling_type": "WaterCooled", + "heating_type": "All Other", + "subcategory": "CRAC", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.4, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "PTAC", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": 13.8, + "ptac_eer_coefficient_2": 0.3, + "minimum_scop": null, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "PTAC", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": 14, + "ptac_eer_coefficient_2": 0.3, + "minimum_scop": null, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_seasonal_efficiency": 13, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 14, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11.2, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 10.8, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 240000, + "maximum_capacity": 759999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.8, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 9.9, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 760000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.5, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 9.6, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 12.7, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 10.8, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 12.2, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 240000, + "maximum_capacity": 759999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.8, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11.4, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 760000, + "maximum_capacity": 9999999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.5, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 13, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11.2, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 10.8, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 240000, + "maximum_capacity": 759999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.8, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 9.9, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 760000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.5, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 9.6, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 12.7, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 10.8, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 12.2, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 240000, + "maximum_capacity": 759999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.8, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11.4, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 760000, + "maximum_capacity": 9999999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.5, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "CRAC", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.2, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "CRAC", + "minimum_capacity": 65000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.1, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "CRAC", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 1.9, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "PTAC", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": 13.8, + "ptac_eer_coefficient_2": 0.3, + "minimum_scop": null, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "PTAC", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": 14, + "ptac_eer_coefficient_2": 0.3, + "minimum_scop": null, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_seasonal_efficiency": 13, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 14, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11.2, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11.4, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11.2, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 240000, + "maximum_capacity": 759999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 10, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 10.1, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 760000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.7, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 9.8, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11.2, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 12.9, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 12.4, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 240000, + "maximum_capacity": 759999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 10, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11.6, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 760000, + "maximum_capacity": 9999999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.7, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11.2, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 13, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11.2, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11.4, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11.2, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 240000, + "maximum_capacity": 759999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 10, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 10.1, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 760000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "12/31/2015", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.7, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 9.8, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11.2, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 12.9, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 12.4, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 240000, + "maximum_capacity": 759999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 10, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11.6, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 760000, + "maximum_capacity": 9999999, + "start_date": "1/1/2016", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.7, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11.2, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "heating_type": "All Other", + "subcategory": "CRAC", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.6, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "heating_type": "All Other", + "subcategory": "CRAC", + "minimum_capacity": 65000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.5, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units" + }, + { + "template": "90.1-2013", + "cooling_type": "WaterCooled", + "heating_type": "All Other", + "subcategory": "CRAC", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.4, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units" + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "PTAC", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": 13.8, + "ptac_eer_coefficient_2": 0.3, + "minimum_scop": null, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "PTAC", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": 14, + "ptac_eer_coefficient_2": 0.3, + "minimum_scop": null, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 14, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11.2, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 10.8, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 240000, + "maximum_capacity": 759999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.8, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 9.9, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 760000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.5, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 9.6, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 13, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11.2, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 10.8, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 240000, + "maximum_capacity": 759999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.8, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 9.9, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 760000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.5, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 9.6, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "CRAC", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.3, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "CRAC", + "minimum_capacity": 65000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.2, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "CRAC", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "PTAC", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": 13.8, + "ptac_eer_coefficient_2": 0.3, + "minimum_scop": null, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "PTAC", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": 14, + "ptac_eer_coefficient_2": 0.3, + "minimum_scop": null, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "12/31/2014", + "minimum_seasonal_efficiency": 13, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "1/1/2015", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 14, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11.2, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11.4, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11.2, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 240000, + "maximum_capacity": 759999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 10, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 10.1, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 760000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.7, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 9.8, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 13, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11.2, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11.4, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11.2, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 240000, + "maximum_capacity": 759999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 10, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 10.1, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 760000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.7, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 9.8, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2016", + "cooling_type": "WaterCooled", + "heating_type": "All Other", + "subcategory": "CRAC", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.5, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units" + }, + { + "template": "90.1-2016", + "cooling_type": "WaterCooled", + "heating_type": "All Other", + "subcategory": "CRAC", + "minimum_capacity": 65000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.4, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units" + }, + { + "template": "90.1-2016", + "cooling_type": "WaterCooled", + "heating_type": "All Other", + "subcategory": "CRAC", + "minimum_capacity": 240000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.25, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units" + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "PTAC", + "minimum_capacity": 0, + "maximum_capacity": 6999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11.9, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "PTAC", + "minimum_capacity": 6999, + "maximum_capacity": 14999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": 14, + "ptac_eer_coefficient_2": 0.3, + "minimum_scop": null, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "PTAC", + "minimum_capacity": 14999, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.5, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 14, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 12.7, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 10.8, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 12.2, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 240000, + "maximum_capacity": 759999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.8, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11.4, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Single Package", + "minimum_capacity": 760000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.5, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 13, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 12.7, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 10.8, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 12.2, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 240000, + "maximum_capacity": 759999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.8, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11.4, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "All Other", + "subcategory": "Split System", + "minimum_capacity": 760000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.5, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "CRAC", + "minimum_capacity": 0, + "maximum_capacity": 79999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.7, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for downflow units" + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "CRAC", + "minimum_capacity": 80000, + "maximum_capacity": 294999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.58, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for downflow units" + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "CRAC", + "minimum_capacity": 295000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.36, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for downflow units" + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "PTAC", + "minimum_capacity": 0, + "maximum_capacity": 6999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11.9, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "PTAC", + "minimum_capacity": 6999, + "maximum_capacity": 14999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": 14, + "ptac_eer_coefficient_2": 0.3, + "minimum_scop": null, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "PTAC", + "minimum_capacity": 14999, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.5, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 14, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11.2, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 12.9, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 12.4, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 240000, + "maximum_capacity": 759999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 10, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11.6, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Single Package", + "minimum_capacity": 760000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.7, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11.2, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 0, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": 13, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11.2, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 12.9, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 135000, + "maximum_capacity": 239999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 11, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 12.4, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 240000, + "maximum_capacity": 759999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 10, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11.6, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "AirCooled", + "heating_type": "Electric Resistance or None", + "subcategory": "Split System", + "minimum_capacity": 760000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": 9.7, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": 11.2, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": null, + "cool_cap_ft": "PSZ-AC_Unitary_PackagecoolCapFT", + "cool_cap_fflow": "PSZ-AC_Unitary_PackagecoolFFF", + "cool_eir_ft": "PSZ-AC DX Unitary Package EIRFT", + "cool_eir_fflow": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "cool_plf_fplr": "PSZ-AC_Unitary_PackagecoolPLR", + "annotation": null + }, + { + "template": "90.1-2019", + "cooling_type": "WaterCooled", + "heating_type": "All Other", + "subcategory": "CRAC", + "minimum_capacity": 0, + "maximum_capacity": 79999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.82, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for water cooled downflow units" + }, + { + "template": "90.1-2019", + "cooling_type": "WaterCooled", + "heating_type": "All Other", + "subcategory": "CRAC", + "minimum_capacity": 80000, + "maximum_capacity": 294999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.73, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for water cooled downflow units" + }, + { + "template": "90.1-2019", + "cooling_type": "WaterCooled", + "heating_type": "All Other", + "subcategory": "CRAC", + "minimum_capacity": 295000, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_seasonal_efficiency": null, + "minimum_energy_efficiency_ratio": null, + "minimum_integrated_part_load_value": null, + "minimum_integrated_energy_efficiency_ratio": null, + "ptac_eer_coefficient_1": null, + "ptac_eer_coefficient_2": null, + "minimum_scop": 2.67, + "cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT", + "cool_cap_fflow": "DX Coil Cap-FF", + "cool_eir_ft": "PSZ-AC DX Coil EIR-FT", + "cool_eir_fflow": "Split DX Coil EIR-FF", + "cool_plf_fplr": "HPACCOOLPLFFPLR", + "annotation": "ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for water cooled downflow units" + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_heaters_90_1.json b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_heaters_90_1.json new file mode 100644 index 0000000000..31bb8473b9 --- /dev/null +++ b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_heaters_90_1.json @@ -0,0 +1,410 @@ +[ + { + "template": "90.1-2004", + "fuel_type": "Electricity", + "minimum_capacity": 0, + "maximum_capacity": 40945.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.93, + "energy_factor_volume_derate": 0.00132, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "annotation": "From 90.1-2004 Table 7.8" + }, + { + "template": "90.1-2004", + "fuel_type": "Electricity", + "minimum_capacity": 40946, + "maximum_capacity": 99999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": 20, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": 35, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "annotation": "From 90.1-2004 Table 7.8" + }, + { + "template": "90.1-2004", + "fuel_type": "NaturalGas", + "minimum_capacity": 0, + "maximum_capacity": 74999.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.62, + "energy_factor_volume_derate": 0.0019, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "annotation": "From 90.1-2004 Table 7.8" + }, + { + "template": "90.1-2004", + "fuel_type": "NaturalGas", + "minimum_capacity": 75000, + "maximum_capacity": 99999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "annotation": "From 90.1-2004 Table 7.8" + }, + { + "template": "90.1-2007", + "fuel_type": "Electricity", + "minimum_capacity": 0, + "maximum_capacity": 40945.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.93, + "energy_factor_volume_derate": 0.00132, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "annotation": "From 90.1-2007 Table 7.8" + }, + { + "template": "90.1-2007", + "fuel_type": "Electricity", + "minimum_capacity": 40946, + "maximum_capacity": 99999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": 20, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": 35, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "annotation": "From 90.1-2007 Table 7.8" + }, + { + "template": "90.1-2007", + "fuel_type": "NaturalGas", + "minimum_capacity": 0, + "maximum_capacity": 74999.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.62, + "energy_factor_volume_derate": 0.0019, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "annotation": "From 90.1-2007 Table 7.8" + }, + { + "template": "90.1-2007", + "fuel_type": "NaturalGas", + "minimum_capacity": 75000, + "maximum_capacity": 99999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "annotation": "From 90.1-2007 Table 7.8" + }, + { + "template": "90.1-2010", + "fuel_type": "Electricity", + "minimum_capacity": 0, + "maximum_capacity": 40945.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.97, + "energy_factor_volume_derate": 0.00132, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "annotation": "From 90.1-2010 Table 7.8" + }, + { + "template": "90.1-2010", + "fuel_type": "Electricity", + "minimum_capacity": 40946, + "maximum_capacity": 99999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": 20, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": 35, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "annotation": "From 90.1-2010 Table 7.8" + }, + { + "template": "90.1-2010", + "fuel_type": "NaturalGas", + "minimum_capacity": 0, + "maximum_capacity": 74999.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.67, + "energy_factor_volume_derate": 0.0019, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "annotation": "From 90.1-2010 Table 7.8" + }, + { + "template": "90.1-2010", + "fuel_type": "NaturalGas", + "minimum_capacity": 75000, + "maximum_capacity": 99999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "annotation": "From 90.1-2010 Table 7.8" + }, + { + "template": "90.1-2013", + "fuel_type": "Electricity", + "minimum_capacity": 0, + "maximum_capacity": 40945.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.97, + "energy_factor_volume_derate": 0.00132, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "annotation": "From 90.1-2013 Table 7.8" + }, + { + "template": "90.1-2013", + "fuel_type": "Electricity", + "minimum_capacity": 40946, + "maximum_capacity": 99999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "hourly_loss_base": 0.3, + "hourly_loss_volume_allowance": 27, + "thermal_efficiency": null, + "annotation": "From 90.1-2013 Table 7.8" + }, + { + "template": "90.1-2013", + "fuel_type": "NaturalGas", + "minimum_capacity": 0, + "maximum_capacity": 74999.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.67, + "energy_factor_volume_derate": 0.0019, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "annotation": "From 90.1-2013 Table 7.8" + }, + { + "template": "90.1-2013", + "fuel_type": "NaturalGas", + "minimum_capacity": 75000, + "maximum_capacity": 99999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "annotation": "From 90.1-2013 Table 7.8" + }, + { + "template": "90.1-2016", + "fuel_type": "Electricity", + "minimum_capacity": 0, + "maximum_capacity": 40945.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.96, + "energy_factor_volume_derate": 0.0003, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "annotation": "From 90.1-2016 Table F-2, Rated Storage Volume <= 55 gal" + }, + { + "template": "90.1-2016", + "fuel_type": "Electricity", + "minimum_capacity": 40946, + "maximum_capacity": 99999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "hourly_loss_base": 0.3, + "hourly_loss_volume_allowance": 27, + "thermal_efficiency": null, + "annotation": null + }, + { + "template": "90.1-2016", + "fuel_type": "NaturalGas", + "minimum_capacity": 0, + "maximum_capacity": 74999.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.675, + "energy_factor_volume_derate": 0.0015, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "annotation": "From 90.1-2016 Table F-2, Rated Storage Volume <= 55 gal" + }, + { + "template": "90.1-2016", + "fuel_type": "NaturalGas", + "minimum_capacity": 75000, + "maximum_capacity": 99999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "annotation": null + }, + { + "template": "90.1-2019", + "fuel_type": "Electricity", + "minimum_capacity": 0, + "maximum_capacity": 40945.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.96, + "energy_factor_volume_derate": 0.0003, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "annotation": "Same as 90.1-2016 as placeholder; 90.1-2019 Table F-2 uses UEF" + }, + { + "template": "90.1-2019", + "fuel_type": "Electricity", + "minimum_capacity": 40946, + "maximum_capacity": 99999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "hourly_loss_base": 0.3, + "hourly_loss_volume_allowance": 27, + "thermal_efficiency": null, + "annotation": null + }, + { + "template": "90.1-2019", + "fuel_type": "NaturalGas", + "minimum_capacity": 0, + "maximum_capacity": 74999.99, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.675, + "energy_factor_volume_derate": 0.0015, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "annotation": "Same as 90.1-2016 as placeholder; 90.1-2019 Table F-2 uses UEF" + }, + { + "template": "90.1-2019", + "fuel_type": "NaturalGas", + "minimum_capacity": 75000, + "maximum_capacity": 99999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "annotation": null + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1.json b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1.json new file mode 100644 index 0000000000..66a267103d --- /dev/null +++ b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1.json @@ -0,0 +1,164 @@ +[ + { + "template": "90.1-2004", + "minimum_capacity": 0, + "maximum_capacity": 16999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 11.2, + "annotation": "From 90.1-2004 Table 6.8.1B" + }, + { + "template": "90.1-2004", + "minimum_capacity": 17000, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 12, + "annotation": "From 90.1-2004 Table 6.8.1B" + }, + { + "template": "90.1-2004", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 12, + "annotation": "From 90.1-2004 Table 6.8.1B" + }, + { + "template": "90.1-2007", + "minimum_capacity": 0, + "maximum_capacity": 16999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 11.2, + "annotation": "From 90.1-2007 Table 6.8.1B" + }, + { + "template": "90.1-2007", + "minimum_capacity": 17000, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 12, + "annotation": "From 90.1-2007 Table 6.8.1B" + }, + { + "template": "90.1-2007", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 12, + "annotation": "From 90.1-2007 Table 6.8.1B" + }, + { + "template": "90.1-2010", + "minimum_capacity": 0, + "maximum_capacity": 16999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 11.2, + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2010", + "minimum_capacity": 17000, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 12, + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2010", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 12, + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2013", + "minimum_capacity": 0, + "maximum_capacity": 16999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 12.2, + "annotation": "From 90.1-2013 Table 6.8.1-2" + }, + { + "template": "90.1-2013", + "minimum_capacity": 17000, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 13, + "annotation": "From 90.1-2013 Table 6.8.1-2" + }, + { + "template": "90.1-2013", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 13, + "annotation": "From 90.1-2013 Table 6.8.1-2" + }, + { + "template": "90.1-2016", + "minimum_capacity": 0, + "maximum_capacity": 16999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 12.2, + "annotation": null + }, + { + "template": "90.1-2016", + "minimum_capacity": 17000, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 13, + "annotation": null + }, + { + "template": "90.1-2016", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 13, + "annotation": null + }, + { + "template": "90.1-2019", + "minimum_capacity": 0, + "maximum_capacity": 16999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 12.2, + "annotation": null + }, + { + "template": "90.1-2019", + "minimum_capacity": 17000, + "maximum_capacity": 64999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 13, + "annotation": null + }, + { + "template": "90.1-2019", + "minimum_capacity": 65000, + "maximum_capacity": 134999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_full_load_efficiency": 13, + "annotation": null + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_source_heat_pumps_heating_90_1.json b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_source_heat_pumps_heating_90_1.json new file mode 100644 index 0000000000..850e550e2b --- /dev/null +++ b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_source_heat_pumps_heating_90_1.json @@ -0,0 +1,56 @@ +[ + { + "template": "90.1-2004", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_coefficient_of_performance": 4.2, + "annotation": "From 90.1-2004 Table 6.8.1B" + }, + { + "template": "90.1-2007", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_coefficient_of_performance": 4.2, + "annotation": "From 90.1-2007 Table 6.8.1B" + }, + { + "template": "90.1-2010", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_coefficient_of_performance": 4.2, + "annotation": "From 90.1-2010 Table 6.8.1B" + }, + { + "template": "90.1-2013", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_coefficient_of_performance": 4.3, + "annotation": "From 90.1-2013 Table 6.8.1-2" + }, + { + "template": "90.1-2016", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_coefficient_of_performance": 4.3, + "annotation": "From 90.1-2016 Table 6.8.1-2" + }, + { + "template": "90.1-2019", + "minimum_capacity": 0, + "maximum_capacity": 9999999, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "minimum_coefficient_of_performance": 4.3, + "annotation": "From 90.1-2016 Table 6.8.1-15" + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/level_1_space_types.json b/data/openstudio_standards_data/database_files/level_1_space_types.json new file mode 100644 index 0000000000..d54e912e00 --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_1_space_types.json @@ -0,0 +1,770 @@ +[ + { + "space_type_name": "chapel - visually impaired", + "lighting_space_type_name": "chapel_visually_impaired", + "ventilation_space_type_name": "public_assembly_spaces_religious_workshop", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "recreation/common living - visually impaired", + "lighting_space_type_name": "recreation_common_living_visually_impaired", + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_multi_purpose_assembly", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "atrium < 20 ft height", + "lighting_space_type_name": "atrium_low", + "ventilation_space_type_name": "office_buildings_main_entry_lobbies", + "electric_equipment_space_type_name": "atrium < 20 ft height" + }, + { + "space_type_name": "atrium >= 20 ft and <= 40 ft in height", + "lighting_space_type_name": "atrium_medium", + "ventilation_space_type_name": "office_buildings_main_entry_lobbies", + "electric_equipment_space_type_name": "atrium >= 20 ft and <= 40 ft in height" + }, + { + "space_type_name": "atrium > 40 ft height", + "lighting_space_type_name": "atrium_high", + "ventilation_space_type_name": "office_buildings_main_entry_lobbies", + "electric_equipment_space_type_name": "atrium > 40 ft height" + }, + { + "space_type_name": "audience seating - convention center", + "lighting_space_type_name": "audience_seating_convention_center", + "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", + "electric_equipment_space_type_name": "audience seating - convention center" + }, + { + "space_type_name": "audience seating - exercise center", + "lighting_space_type_name": "audience_seating_exercise_center", + "ventilation_space_type_name": "sports_entertainment_spectator_areas", + "electric_equipment_space_type_name": "audience seating - exercise center" + }, + { + "space_type_name": "audience seating - all other", + "lighting_space_type_name": "audience_seating_general", + "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", + "electric_equipment_space_type_name": "audience seating - all other" + }, + { + "space_type_name": "audience seating - auditorium", + "lighting_space_type_name": "audience_seating_auditorium", + "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", + "electric_equipment_space_type_name": "audience seating - auditorium" + }, + { + "space_type_name": "audience seating - gymnasium", + "lighting_space_type_name": "audience_seating_gymnasium", + "ventilation_space_type_name": "sports_entertainment_spectator_areas", + "electric_equipment_space_type_name": "audience seating - gymnasium" + }, + { + "space_type_name": "audience seating - sports arena", + "lighting_space_type_name": "audience_seating_sports_arena", + "ventilation_space_type_name": "sports_entertainment_spectator_areas", + "electric_equipment_space_type_name": "audience seating - sports arena" + }, + { + "space_type_name": "audience seating - motion picture theater", + "lighting_space_type_name": "audience_seating_motion_picture_theater", + "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", + "electric_equipment_space_type_name": "audience seating - motion picture theater" + }, + { + "space_type_name": "audience seating - penitentiary", + "lighting_space_type_name": "audience_seating_penitentiary", + "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "audience seating - performing arts theater", + "lighting_space_type_name": "audience_seating_performing_arts_theater", + "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", + "electric_equipment_space_type_name": "audience seating - performing arts theater" + }, + { + "space_type_name": "audience seating - religious facility", + "lighting_space_type_name": "audience_seating_religious_facility", + "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", + "electric_equipment_space_type_name": "audience seating - religious facility" + }, + { + "space_type_name": "audience seating - transportation facility", + "lighting_space_type_name": "audience_seating_transportation", + "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "automotive", + "lighting_space_type_name": "automotive", + "ventilation_space_type_name": "miscellaneous_spaces_transportation_waiting", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "banking activity", + "lighting_space_type_name": "banking_activity", + "ventilation_space_type_name": "miscellaneous_spaces_banks_bank_lobbies", + "electric_equipment_space_type_name": "banking activity" + }, + { + "space_type_name": "classroom/lecture/training - all other", + "lighting_space_type_name": "classroom_lecture_training_general", + "ventilation_space_type_name": "educational_facilities_classroom_old", + "electric_equipment_space_type_name": "classroom/lecture/training - all other" + }, + { + "space_type_name": "classroom/lecture/training - penitentiary", + "lighting_space_type_name": "classroom_lecture_training_penitentiary", + "ventilation_space_type_name": "correctional_facilities_dayroom", + "electric_equipment_space_type_name": "classroom/lecture/training - penitentiary" + }, + { + "space_type_name": "classroom - laboratory or shop", + "lighting_space_type_name": "laboratory_classroom", + "ventilation_space_type_name": "educational_facilities_university_college_laboratories", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "classroom/lecture/training - preschool to 12th", + "lighting_space_type_name": "classroom_lecture_training_general", + "ventilation_space_type_name": "educational_facilities_classroom_young", + "electric_equipment_space_type_name": "classroom/lecture/training - preschool to 12th" + }, + { + "space_type_name": "computer room", + "lighting_space_type_name": "computer_room", + "ventilation_space_type_name": "miscellaneous_spaces_computer", + "electric_equipment_space_type_name": "computer room" + }, + { + "space_type_name": "conference/meeting/multipurpose", + "lighting_space_type_name": "conference_meeting_multipurpose", + "ventilation_space_type_name": "general_conference_meeting", + "electric_equipment_space_type_name": "conference/meeting/multipurpose" + }, + { + "space_type_name": "confinement cells", + "lighting_space_type_name": "confinement_cells", + "ventilation_space_type_name": "correctional_facilities_cell", + "electric_equipment_space_type_name": "confinement cells" + }, + { + "space_type_name": "exhibit - convention center", + "lighting_space_type_name": "exhibit_convention_center", + "ventilation_space_type_name": "public_assembly_spaces_museums_galleries", + "electric_equipment_space_type_name": "exhibit - convention center" + }, + { + "space_type_name": "copy/print", + "lighting_space_type_name": "copy_print", + "ventilation_space_type_name": "office_buildings_telephone_data_entry", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "corridor for visually impaired", + "lighting_space_type_name": "corridor_visually_impaired", + "ventilation_space_type_name": "general_conference_corridors", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "corridor - hospital", + "lighting_space_type_name": "corridor_hospital", + "ventilation_space_type_name": "general_conference_corridors", + "electric_equipment_space_type_name": "corridor - hospital" + }, + { + "space_type_name": "corridor - manufacturing facility", + "lighting_space_type_name": "corridor_manufacturing_facility", + "ventilation_space_type_name": "general_conference_corridors", + "electric_equipment_space_type_name": "corridor - manufacturing facility" + }, + { + "space_type_name": "corridor - all other", + "lighting_space_type_name": "corridor_general", + "ventilation_space_type_name": "general_conference_corridors", + "electric_equipment_space_type_name": "corridor - all other" + }, + { + "space_type_name": "courtroom", + "lighting_space_type_name": "courtroom", + "ventilation_space_type_name": "public_assembly_spaces_courtrooms", + "electric_equipment_space_type_name": "courtroom" + }, + { + "space_type_name": "dining - all other", + "lighting_space_type_name": "dining_general", + "ventilation_space_type_name": "food_beverage_service_restaurant_dining_rooms", + "electric_equipment_space_type_name": "dining - all other" + }, + { + "space_type_name": "dining - bar/lounge/leisure", + "lighting_space_type_name": "dining_bar_lounge_leisure", + "ventilation_space_type_name": "food_beverage_service_bars_cocktail_lounges", + "electric_equipment_space_type_name": "dining - bar/lounge/leisure" + }, + { + "space_type_name": "dining - cafeteria/fast food", + "lighting_space_type_name": "dining_cafeteria_fast_food", + "ventilation_space_type_name": "food_beverage_service_cafeteria_fast_food_dining", + "electric_equipment_space_type_name": "dining - cafeteria/fast food" + }, + { + "space_type_name": "dining for visually impaired", + "lighting_space_type_name": "dining_visually_impaired", + "ventilation_space_type_name": "food_beverage_service_restaurant_dining_rooms", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "dining - family", + "lighting_space_type_name": "dining_family", + "ventilation_space_type_name": "food_beverage_service_restaurant_dining_rooms", + "electric_equipment_space_type_name": "dining - family" + }, + { + "space_type_name": "dining - penitentiary", + "lighting_space_type_name": "dining_penitentiary", + "ventilation_space_type_name": "food_beverage_service_restaurant_dining_rooms", + "electric_equipment_space_type_name": "dining - penitentiary" + }, + { + "space_type_name": "dining - hotel", + "lighting_space_type_name": "dining_hotel", + "ventilation_space_type_name": "food_beverage_service_restaurant_dining_rooms", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "dining - motel", + "lighting_space_type_name": "dining_motel", + "ventilation_space_type_name": "food_beverage_service_restaurant_dining_rooms", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "dormitory - living quarters", + "lighting_space_type_name": "dormitory_living_quarters", + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_bedroom_living_room", + "electric_equipment_space_type_name": "dormitory - living quarters" + }, + { + "space_type_name": "electrical/mechanical", + "lighting_space_type_name": "electrical_mechanical", + "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", + "electric_equipment_space_type_name": "electrical/mechanical" + }, + { + "space_type_name": "emergency vehicle garage", + "lighting_space_type_name": "emergency_vehicle_garage", + "ventilation_space_type_name": "miscellaneous_spaces_transportation_waiting", + "electric_equipment_space_type_name": "emergency vehicle garage" + }, + { + "space_type_name": "firestation - sleeping quarters", + "lighting_space_type_name": "firestation_sleeping_quarters", + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_barracks_sleeping_areas", + "electric_equipment_space_type_name": "firestation - sleeping quarters" + }, + { + "space_type_name": "kitchen", + "lighting_space_type_name": "kitchen", + "ventilation_space_type_name": "food_beverage_service_kitchen", + "electric_equipment_space_type_name": "kitchen" + }, + { + "space_type_name": "guest room", + "lighting_space_type_name": "guest_room", + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_barracks_sleeping_areas", + "electric_equipment_space_type_name": "guest room" + }, + { + "space_type_name": "gymnasium exercise area", + "lighting_space_type_name": "gymnasium_exercise_area", + "ventilation_space_type_name": "sports_entertainment_gym_stadium", + "electric_equipment_space_type_name": "gymnasium exercise area" + }, + { + "space_type_name": "gymnasium playing area", + "lighting_space_type_name": "gymnasium_playing_area", + "ventilation_space_type_name": "sports_entertainment_gym_stadium", + "electric_equipment_space_type_name": "gymnasium playing area" + }, + { + "space_type_name": "emergency room", + "lighting_space_type_name": "emergency_room", + "ventilation_space_type_name": "outpatient_health_care_facilities_general_examination_room", + "electric_equipment_space_type_name": "emergency room" + }, + { + "space_type_name": "exam/treatment", + "lighting_space_type_name": "exam_treatment", + "ventilation_space_type_name": "outpatient_health_care_facilities_general_examination_room", + "electric_equipment_space_type_name": "exam/treatment" + }, + { + "space_type_name": "imaging", + "lighting_space_type_name": "imaging", + "ventilation_space_type_name": "outpatient_health_care_facilities_class_1_imaging_rooms", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "medical supply", + "lighting_space_type_name": "medical_supply", + "ventilation_space_type_name": "miscellaneous_spaces_pharmacy", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "nursery", + "lighting_space_type_name": "nursery", + "ventilation_space_type_name": "outpatient_health_care_facilities_psychiatric_consultation_room", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "nurses station", + "lighting_space_type_name": "nurses_station", + "ventilation_space_type_name": "outpatient_health_care_facilities_psychiatric_consultation_room", + "electric_equipment_space_type_name": "nurses station" + }, + { + "space_type_name": "operating room", + "lighting_space_type_name": "operating_room", + "ventilation_space_type_name": "outpatient_health_care_facilities_general_examination_room", + "electric_equipment_space_type_name": "operating room" + }, + { + "space_type_name": "patient room", + "lighting_space_type_name": "patient_room", + "ventilation_space_type_name": "outpatient_health_care_facilities_physical_therapy_individual_room", + "electric_equipment_space_type_name": "patient room" + }, + { + "space_type_name": "physical therapy", + "lighting_space_type_name": "physical_therapy", + "ventilation_space_type_name": "outpatient_health_care_facilities_physical_therapy_exercise_area", + "electric_equipment_space_type_name": "physical therapy" + }, + { + "space_type_name": "recovery", + "lighting_space_type_name": "recovery", + "ventilation_space_type_name": "outpatient_health_care_facilities_urgent_care_examination_room", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "judges chambers", + "lighting_space_type_name": "judges_chambers", + "ventilation_space_type_name": "public_assembly_spaces_legislative_chambers", + "electric_equipment_space_type_name": "judges chambers" + }, + { + "space_type_name": "laboratory", + "lighting_space_type_name": "laboratory_all_other", + "ventilation_space_type_name": "educational_facilities_science_laboratories", + "electric_equipment_space_type_name": "laboratory" + }, + { + "space_type_name": "library - reading", + "lighting_space_type_name": "library_reading", + "ventilation_space_type_name": "public_assembly_spaces_libraries", + "electric_equipment_space_type_name": "library - reading" + }, + { + "space_type_name": "library - stacks", + "lighting_space_type_name": "library_stacks", + "ventilation_space_type_name": "public_assembly_spaces_libraries", + "electric_equipment_space_type_name": "library - stacks" + }, + { + "space_type_name": "library - cataloging", + "lighting_space_type_name": "library_cataloging", + "ventilation_space_type_name": "public_assembly_spaces_libraries", + "electric_equipment_space_type_name": "library - cataloging" + }, + { + "space_type_name": "loading dock", + "lighting_space_type_name": "loading_dock", + "ventilation_space_type_name": "miscellaneous_spaces_sorting_packing_light_assembly", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "lobby - all other", + "lighting_space_type_name": "lobby_general", + "ventilation_space_type_name": "public_assembly_spaces_lobbies", + "electric_equipment_space_type_name": "lobby - all other" + }, + { + "space_type_name": "lobby - elevator", + "lighting_space_type_name": "lobby_elevator", + "ventilation_space_type_name": "public_assembly_spaces_lobbies", + "electric_equipment_space_type_name": "lobby - elevator" + }, + { + "space_type_name": "lobby for visually impaired", + "lighting_space_type_name": "lobby_visually_impaired", + "ventilation_space_type_name": "public_assembly_spaces_lobbies", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "lobby - hotel", + "lighting_space_type_name": "lobby_hotel", + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_lobbies_prefunction", + "electric_equipment_space_type_name": "lobby - hotel" + }, + { + "space_type_name": "lobby - motion picture theater", + "lighting_space_type_name": "lobby_motion_picture_theater", + "ventilation_space_type_name": "public_assembly_spaces_lobbies", + "electric_equipment_space_type_name": "lobby - motion picture theater" + }, + { + "space_type_name": "lobby - performing arts theater", + "lighting_space_type_name": "lobby_performing_arts_theater", + "ventilation_space_type_name": "public_assembly_spaces_lobbies", + "electric_equipment_space_type_name": "lobby - performing arts theater" + }, + { + "space_type_name": "locker room", + "lighting_space_type_name": "locker_room", + "ventilation_space_type_name": "general_break_rooms", + "electric_equipment_space_type_name": "locker room" + }, + { + "space_type_name": "lounge/breakroom - all other", + "lighting_space_type_name": "lounge_breakroom_general", + "ventilation_space_type_name": "general_break_rooms", + "electric_equipment_space_type_name": "lounge/breakroom - all other" + }, + { + "space_type_name": "lounge/breakroom - healthcare facility", + "lighting_space_type_name": "lounge_breakroom_healthcare_facility", + "ventilation_space_type_name": "general_break_rooms", + "electric_equipment_space_type_name": "lounge/breakroom - healthcare facility" + }, + { + "space_type_name": "laundry/washing", + "lighting_space_type_name": "laundry_washing", + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_laundry_rooms", + "electric_equipment_space_type_name": "laundry/washing" + }, + { + "space_type_name": "detailed manufacuring", + "lighting_space_type_name": "detailed_manufacuring", + "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "manufacturing equipment room", + "lighting_space_type_name": "manufacturing_equipment_room", + "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", + "electric_equipment_space_type_name": "manufacturing equipment room" + }, + { + "space_type_name": "manufacturing extra high bay", + "lighting_space_type_name": "manufacturing_extra_high_bay", + "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "manufacturing high bay", + "lighting_space_type_name": "manufacturing_high_bay", + "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "manufacturing low bay", + "lighting_space_type_name": "manufacturing_low_bay", + "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", + "electric_equipment_space_type_name": "manufacturing low bay" + }, + { + "space_type_name": "manufacturing control", + "lighting_space_type_name": "manufacturing_control", + "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "museum exhibit area", + "lighting_space_type_name": "museum_exhibit_area", + "ventilation_space_type_name": "public_assembly_spaces_museums_galleries", + "electric_equipment_space_type_name": "museum exhibit area" + }, + { + "space_type_name": "museum restoration", + "lighting_space_type_name": "museum_restoration", + "ventilation_space_type_name": "public_assembly_spaces_museums_galleries", + "electric_equipment_space_type_name": "museum restoration" + }, + { + "space_type_name": "performing arts dressing room", + "lighting_space_type_name": "performing_arts_dressing_room", + "ventilation_space_type_name": "retail_mall_common_areas", + "electric_equipment_space_type_name": "performing arts dressing room" + }, + { + "space_type_name": "office - enclosed <= 250 sf", + "lighting_space_type_name": "office_enclosed_small", + "ventilation_space_type_name": "office_buildings_office_space", + "electric_equipment_space_type_name": "office - enclosed <= 250 sf" + }, + { + "space_type_name": "office - enclosed > 250 sf", + "lighting_space_type_name": "office_enclosed_large", + "ventilation_space_type_name": "office_buildings_office_space", + "electric_equipment_space_type_name": "office - enclosed > 250 sf" + }, + { + "space_type_name": "office - open", + "lighting_space_type_name": "office_open", + "ventilation_space_type_name": "office_buildings_office_space", + "electric_equipment_space_type_name": "office - open" + }, + { + "space_type_name": "parking area, interior", + "lighting_space_type_name": "parking_area_interior", + "ventilation_space_type_name": "miscellaneous_spaces_transportation_waiting", + "electric_equipment_space_type_name": "parking area, interior" + }, + { + "space_type_name": "pharmacy", + "lighting_space_type_name": "pharmacy", + "ventilation_space_type_name": "miscellaneous_spaces_pharmacy", + "electric_equipment_space_type_name": "pharmacy" + }, + { + "space_type_name": "post office - sorting area", + "lighting_space_type_name": "post_office_sorting_area", + "ventilation_space_type_name": "miscellaneous_spaces_sorting_packing_light_assembly", + "electric_equipment_space_type_name": "post office - sorting area" + }, + { + "space_type_name": "fellowship hall - religious facility", + "lighting_space_type_name": "fellowship_hall_religious_facility", + "ventilation_space_type_name": "public_assembly_spaces_religious_workshop", + "electric_equipment_space_type_name": "fellowship hall - religious facility" + }, + { + "space_type_name": "worship/pulpit/choir area", + "lighting_space_type_name": "worship_pulpit_choir_area", + "ventilation_space_type_name": "public_assembly_spaces_religious_workshop", + "electric_equipment_space_type_name": "worship/pulpit/choir area" + }, + { + "space_type_name": "restroom - all other", + "lighting_space_type_name": "restroom_all_other", + "ventilation_space_type_name": null, + "electric_equipment_space_type_name": "restroom - all other" + }, + { + "space_type_name": "restroom - visually impaired", + "lighting_space_type_name": "restroom_visually_impaired", + "ventilation_space_type_name": null, + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "retail dressing room", + "lighting_space_type_name": "retail_dressing_room", + "ventilation_space_type_name": "retail_mall_common_areas", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "retail mall concourse", + "lighting_space_type_name": "retail_mall_concourse", + "ventilation_space_type_name": "retail_mall_common_areas", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "seating area, general", + "lighting_space_type_name": "seating_area_general", + "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", + "electric_equipment_space_type_name": "seating area, general" + }, + { + "space_type_name": "sports arena playing area, class I", + "lighting_space_type_name": "sports_arena_playing_area_class_I", + "ventilation_space_type_name": "sports_entertainment_sports_arena", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "sports arena playing area, class II", + "lighting_space_type_name": "sports_arena_playing_area_class_II", + "ventilation_space_type_name": "sports_entertainment_sports_arena", + "electric_equipment_space_type_name": "sports arena playing area, class II" + }, + { + "space_type_name": "sports arena playing area, class III", + "lighting_space_type_name": "sports_arena_playing_area_class_III", + "ventilation_space_type_name": "sports_entertainment_sports_arena", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "sports arena playing area, class IV", + "lighting_space_type_name": "sports_arena_playing_area_class_IV", + "ventilation_space_type_name": "sports_entertainment_sports_arena", + "electric_equipment_space_type_name": "sports arena playing area, class IV" + }, + { + "space_type_name": "sports arena - ring sports area", + "lighting_space_type_name": "sports_arena_ring_sports_area", + "ventilation_space_type_name": "sports_entertainment_sports_arena", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "sports arena - court sports area", + "lighting_space_type_name": "sports_arena_court_sports_area", + "ventilation_space_type_name": "sports_entertainment_sports_arena", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "sports arena - indoor playing field", + "lighting_space_type_name": "sports_arena_indoor_playing_field", + "ventilation_space_type_name": "sports_entertainment_sports_arena", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "stairwell", + "lighting_space_type_name": "stairwell", + "ventilation_space_type_name": "general_conference_corridors", + "electric_equipment_space_type_name": "stairwell" + }, + { + "space_type_name": "storage < 50 sf - all other", + "lighting_space_type_name": "storage_ all_other_small", + "ventilation_space_type_name": "general_conference_storage_rooms", + "electric_equipment_space_type_name": "storage < 50 sf - all other" + }, + { + "space_type_name": "storage 50 to 1000 sf - all other", + "lighting_space_type_name": "storage_ all_other_large", + "ventilation_space_type_name": "general_conference_storage_rooms", + "electric_equipment_space_type_name": "storage 50 to 1000 sf - all other" + }, + { + "space_type_name": "storage < 50 sf - hospital", + "lighting_space_type_name": "storage_hospital_small", + "ventilation_space_type_name": "general_conference_storage_rooms", + "electric_equipment_space_type_name": "storage < 50 sf - hospital" + }, + { + "space_type_name": "storage 50 to 1000 sf - hospital", + "lighting_space_type_name": "storage_hospital_large", + "ventilation_space_type_name": "general_conference_storage_rooms", + "electric_equipment_space_type_name": "storage 50 to 1000 sf - hospital" + }, + { + "space_type_name": "storage - inactive", + "lighting_space_type_name": "storage_inactive", + "ventilation_space_type_name": "general_conference_storage_rooms", + "electric_equipment_space_type_name": "storage - inactive" + }, + { + "space_type_name": "storage, inactive - museum", + "lighting_space_type_name": "storage_inactive_museum", + "ventilation_space_type_name": "general_conference_storage_rooms", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "airport concourse", + "lighting_space_type_name": "airport_concourse", + "ventilation_space_type_name": "office_buildings_reception_areas", + "electric_equipment_space_type_name": "airport concourse" + }, + { + "space_type_name": "baggage/carousel", + "lighting_space_type_name": "baggage_carousel", + "ventilation_space_type_name": "office_buildings_reception_areas", + "electric_equipment_space_type_name": "baggage/carousel" + }, + { + "space_type_name": "transportation ticket counter", + "lighting_space_type_name": "transportation_ticket_counter", + "ventilation_space_type_name": "office_buildings_reception_areas", + "electric_equipment_space_type_name": "transportation ticket counter" + }, + { + "space_type_name": "vehicular maintenance", + "lighting_space_type_name": "vehicular_maintenance", + "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", + "electric_equipment_space_type_name": "vehicular maintenance" + }, + { + "space_type_name": "warehouse - bulk storage", + "lighting_space_type_name": "warehouse_bulk_storage", + "ventilation_space_type_name": "miscellaneous_spaces_warehouses", + "electric_equipment_space_type_name": "warehouse - bulk storage" + }, + { + "space_type_name": "warehouse - fine storage", + "lighting_space_type_name": "warehouse_fine_storage", + "ventilation_space_type_name": "miscellaneous_spaces_warehouses", + "electric_equipment_space_type_name": "warehouse - fine storage" + }, + { + "space_type_name": "workshop", + "lighting_space_type_name": "workshop", + "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", + "electric_equipment_space_type_name": "workshop" + }, + { + "space_type_name": "sales", + "lighting_space_type_name": "sales", + "ventilation_space_type_name": "retail_sales", + "electric_equipment_space_type_name": "sales" + }, + { + "space_type_name": "sales - display type 1", + "lighting_space_type_name": "sales_display_type_1", + "ventilation_space_type_name": "retail_sales", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "sales - display type 2", + "lighting_space_type_name": "sales_display_type_2", + "ventilation_space_type_name": "retail_sales", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "sales - display type 3", + "lighting_space_type_name": "sales_display_type_3", + "ventilation_space_type_name": "retail_sales", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "sales - display type 4", + "lighting_space_type_name": "sales_display_type_4", + "ventilation_space_type_name": "retail_sales", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "guest room - highway", + "lighting_space_type_name": "guest_room", + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_barracks_sleeping_areas", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "lodging dining - highway", + "lighting_space_type_name": "dining_general", + "ventilation_space_type_name": "food_beverage_service_restaurant_dining_rooms", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "audience seating - classroom/lecture/training", + "lighting_space_type_name": "audience_seating_general", + "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "audience seating - conference/meeting/multipurpose", + "lighting_space_type_name": "audience_seating_general", + "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "audience seating - corridor/transition", + "lighting_space_type_name": "audience_seating_general", + "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", + "electric_equipment_space_type_name": null + }, + { + "space_type_name": "guest room - bathroom", + "lighting_space_type_name": "guest_room", + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_barracks_sleeping_areas", + "electric_equipment_space_type_name": null + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/level_2_electric_equipment.json b/data/openstudio_standards_data/database_files/level_2_electric_equipment.json new file mode 100644 index 0000000000..48082959b2 --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_2_electric_equipment.json @@ -0,0 +1,722 @@ +[ + { + "electric_equipment_space_type_name": "corridor - all other", + "electric_equipment_minimum_epd": 0, + "electric_equipment_average_epd": 0.28, + "electric_equipment_median_epd": 0.24, + "electric_equipment_maximum_epd": 0.82, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "dining - all other", + "electric_equipment_minimum_epd": 0.32, + "electric_equipment_average_epd": 0.55, + "electric_equipment_median_epd": 0.55, + "electric_equipment_maximum_epd": 0.82, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "electrical/mechanical", + "electric_equipment_minimum_epd": 0, + "electric_equipment_average_epd": 0, + "electric_equipment_median_epd": 0, + "electric_equipment_maximum_epd": 0, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "kitchen", + "electric_equipment_minimum_epd": 0.3, + "electric_equipment_average_epd": 0.76, + "electric_equipment_median_epd": 0.71, + "electric_equipment_maximum_epd": 2.52, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "laboratory", + "electric_equipment_minimum_epd": 0.49, + "electric_equipment_average_epd": 0.78, + "electric_equipment_median_epd": 0.7, + "electric_equipment_maximum_epd": 2.02, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "lobby - all other", + "electric_equipment_minimum_epd": 0.16, + "electric_equipment_average_epd": 0.41, + "electric_equipment_median_epd": 0.35, + "electric_equipment_maximum_epd": 0.83, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "locker room", + "electric_equipment_minimum_epd": 0, + "electric_equipment_average_epd": 0.38, + "electric_equipment_median_epd": 0.44, + "electric_equipment_maximum_epd": 0.97, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "lounge/breakroom - all other", + "electric_equipment_minimum_epd": 0, + "electric_equipment_average_epd": 0.49, + "electric_equipment_median_epd": 0.52, + "electric_equipment_maximum_epd": 0.88, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "office - enclosed <= 250 sf", + "electric_equipment_minimum_epd": 0.51, + "electric_equipment_average_epd": 0.68, + "electric_equipment_median_epd": 0.68, + "electric_equipment_maximum_epd": 0.89, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "office - enclosed > 250 sf", + "electric_equipment_minimum_epd": 0.65, + "electric_equipment_average_epd": 0.7, + "electric_equipment_median_epd": 0.69, + "electric_equipment_maximum_epd": 0.82, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "office - open", + "electric_equipment_minimum_epd": 0.53, + "electric_equipment_average_epd": 0.66, + "electric_equipment_median_epd": 0.67, + "electric_equipment_maximum_epd": 0.81, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "restroom - all other", + "electric_equipment_minimum_epd": 0, + "electric_equipment_average_epd": 0, + "electric_equipment_median_epd": 0, + "electric_equipment_maximum_epd": 0, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "stairwell", + "electric_equipment_minimum_epd": 0, + "electric_equipment_average_epd": 0.25, + "electric_equipment_median_epd": 0.25, + "electric_equipment_maximum_epd": 0.53, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "storage < 50 sf - all other", + "electric_equipment_minimum_epd": 0, + "electric_equipment_average_epd": 0, + "electric_equipment_median_epd": 0, + "electric_equipment_maximum_epd": 0, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "storage 50 to 1000 sf - all other", + "electric_equipment_minimum_epd": 0, + "electric_equipment_average_epd": 0, + "electric_equipment_median_epd": 0, + "electric_equipment_maximum_epd": 0, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "vehicular maintenance", + "electric_equipment_minimum_epd": 0.65, + "electric_equipment_average_epd": 0.69, + "electric_equipment_median_epd": 0.69, + "electric_equipment_maximum_epd": 0.73, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "workshop", + "electric_equipment_minimum_epd": 0, + "electric_equipment_average_epd": 0.54, + "electric_equipment_median_epd": 0.57, + "electric_equipment_maximum_epd": 0.74, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "atrium - first three floors", + "electric_equipment_minimum_epd": 0, + "electric_equipment_average_epd": 0.52, + "electric_equipment_median_epd": 0.54, + "electric_equipment_maximum_epd": 0.75, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "audience seating - convention center", + "electric_equipment_minimum_epd": 0.63, + "electric_equipment_average_epd": 0.63, + "electric_equipment_median_epd": 0.63, + "electric_equipment_maximum_epd": 0.63, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "classroom/lecture/training - all other", + "electric_equipment_minimum_epd": 0.5, + "electric_equipment_average_epd": 0.63, + "electric_equipment_median_epd": 0.62, + "electric_equipment_maximum_epd": 0.8, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "conference/meeting/multipurpose", + "electric_equipment_minimum_epd": 0.42, + "electric_equipment_average_epd": 0.62, + "electric_equipment_median_epd": 0.62, + "electric_equipment_maximum_epd": 0.97, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "exhibit - convention center", + "electric_equipment_minimum_epd": 0.84, + "electric_equipment_average_epd": 0.84, + "electric_equipment_median_epd": 0.84, + "electric_equipment_maximum_epd": 0.84, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "gymnasium exercise area", + "electric_equipment_minimum_epd": 0.27, + "electric_equipment_average_epd": 0.48, + "electric_equipment_median_epd": 0.49, + "electric_equipment_maximum_epd": 0.68, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "gymnasium playing area", + "electric_equipment_minimum_epd": 0, + "electric_equipment_average_epd": 0.51, + "electric_equipment_median_epd": 0.51, + "electric_equipment_maximum_epd": 1.06, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "laundry/washing", + "electric_equipment_minimum_epd": 0, + "electric_equipment_average_epd": 0.39, + "electric_equipment_median_epd": 0.39, + "electric_equipment_maximum_epd": 0.59, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "lobby - elevator", + "electric_equipment_minimum_epd": 0.32, + "electric_equipment_average_epd": 0.32, + "electric_equipment_median_epd": 0.32, + "electric_equipment_maximum_epd": 0.32, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "nurses station", + "electric_equipment_minimum_epd": 0, + "electric_equipment_average_epd": 0.52, + "electric_equipment_median_epd": 0.57, + "electric_equipment_maximum_epd": 0.85, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "post office - sorting area", + "electric_equipment_minimum_epd": 0, + "electric_equipment_average_epd": 0.23, + "electric_equipment_median_epd": 0.24, + "electric_equipment_maximum_epd": 0.39, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "sales", + "electric_equipment_minimum_epd": 0.41, + "electric_equipment_average_epd": 0.67, + "electric_equipment_median_epd": 0.67, + "electric_equipment_maximum_epd": 0.92, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "sports arena playing area, class IV", + "electric_equipment_minimum_epd": 0.32, + "electric_equipment_average_epd": 0.5, + "electric_equipment_median_epd": 0.64, + "electric_equipment_maximum_epd": 0.69, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "audience seating - all other", + "electric_equipment_minimum_epd": 0.31, + "electric_equipment_average_epd": 0.49, + "electric_equipment_median_epd": 0.46, + "electric_equipment_maximum_epd": 0.75, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "confinement cells", + "electric_equipment_minimum_epd": 0.22, + "electric_equipment_average_epd": 0.26, + "electric_equipment_median_epd": 0.26, + "electric_equipment_maximum_epd": 0.32, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "courtroom", + "electric_equipment_minimum_epd": 0.25, + "electric_equipment_average_epd": 0.4, + "electric_equipment_median_epd": 0.4, + "electric_equipment_maximum_epd": 0.56, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "judges chambers", + "electric_equipment_minimum_epd": 0.5, + "electric_equipment_average_epd": 0.59, + "electric_equipment_median_epd": 0.59, + "electric_equipment_maximum_epd": 0.68, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "library - stacks", + "electric_equipment_minimum_epd": 0, + "electric_equipment_average_epd": 0.2, + "electric_equipment_median_epd": 0.2, + "electric_equipment_maximum_epd": 0.33, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "storage - inactive", + "electric_equipment_minimum_epd": 0, + "electric_equipment_average_epd": 0, + "electric_equipment_median_epd": 0, + "electric_equipment_maximum_epd": 0, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "dining - bar/lounge/leisure", + "electric_equipment_minimum_epd": 0.5, + "electric_equipment_average_epd": 0.5, + "electric_equipment_median_epd": 0.5, + "electric_equipment_maximum_epd": 0.5, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "dining - cafeteria/fast food", + "electric_equipment_minimum_epd": 0.6, + "electric_equipment_average_epd": 0.6, + "electric_equipment_median_epd": 0.6, + "electric_equipment_maximum_epd": 0.6, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "dining - family", + "electric_equipment_minimum_epd": 0.78, + "electric_equipment_average_epd": 0.78, + "electric_equipment_median_epd": 0.78, + "electric_equipment_maximum_epd": 0.78, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "computer room", + "electric_equipment_minimum_epd": 0.69, + "electric_equipment_average_epd": 0.7, + "electric_equipment_median_epd": 0.69, + "electric_equipment_maximum_epd": 0.73, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "dormitory - living quarters", + "electric_equipment_minimum_epd": 0.23, + "electric_equipment_average_epd": 0.44, + "electric_equipment_median_epd": 0.42, + "electric_equipment_maximum_epd": 0.62, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "audience seating - exercise center", + "electric_equipment_minimum_epd": 0.6, + "electric_equipment_average_epd": 0.6, + "electric_equipment_median_epd": 0.6, + "electric_equipment_maximum_epd": 0.6, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "exam/treatment", + "electric_equipment_minimum_epd": 0.51, + "electric_equipment_average_epd": 0.56, + "electric_equipment_median_epd": 0.53, + "electric_equipment_maximum_epd": 0.66, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "library - reading", + "electric_equipment_minimum_epd": 0.32, + "electric_equipment_average_epd": 0.49, + "electric_equipment_median_epd": 0.46, + "electric_equipment_maximum_epd": 0.71, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "emergency vehicle garage", + "electric_equipment_minimum_epd": 0.39, + "electric_equipment_average_epd": 0.39, + "electric_equipment_median_epd": 0.39, + "electric_equipment_maximum_epd": 0.39, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "firestation - sleeping quarters", + "electric_equipment_minimum_epd": 0.37, + "electric_equipment_average_epd": 0.37, + "electric_equipment_median_epd": 0.37, + "electric_equipment_maximum_epd": 0.37, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "parking area, interior", + "electric_equipment_minimum_epd": 0.11, + "electric_equipment_average_epd": 0.27, + "electric_equipment_median_epd": 0.3, + "electric_equipment_maximum_epd": 0.32, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "audience seating - gymnasium", + "electric_equipment_minimum_epd": 0.64, + "electric_equipment_average_epd": 0.64, + "electric_equipment_median_epd": 0.64, + "electric_equipment_maximum_epd": 0.64, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "emergency room", + "electric_equipment_minimum_epd": 0.61, + "electric_equipment_average_epd": 0.62, + "electric_equipment_median_epd": 0.62, + "electric_equipment_maximum_epd": 0.62, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "patient room", + "electric_equipment_minimum_epd": 0.71, + "electric_equipment_average_epd": 0.72, + "electric_equipment_median_epd": 0.72, + "electric_equipment_maximum_epd": 0.73, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "pharmacy", + "electric_equipment_minimum_epd": 0.47, + "electric_equipment_average_epd": 0.64, + "electric_equipment_median_epd": 0.72, + "electric_equipment_maximum_epd": 0.74, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "corridor - hospital", + "electric_equipment_minimum_epd": 0.3, + "electric_equipment_average_epd": 0.3, + "electric_equipment_median_epd": 0.3, + "electric_equipment_maximum_epd": 0.3, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "fellowship hall - religious facility", + "electric_equipment_minimum_epd": 0.36, + "electric_equipment_average_epd": 0.39, + "electric_equipment_median_epd": 0.39, + "electric_equipment_maximum_epd": 0.41, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "lounge/breakroom - healthcare facility", + "electric_equipment_minimum_epd": 0.75, + "electric_equipment_average_epd": 0.75, + "electric_equipment_median_epd": 0.75, + "electric_equipment_maximum_epd": 0.75, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "operating room", + "electric_equipment_minimum_epd": 0.77, + "electric_equipment_average_epd": 0.77, + "electric_equipment_median_epd": 0.77, + "electric_equipment_maximum_epd": 0.77, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "physical therapy", + "electric_equipment_minimum_epd": 0.73, + "electric_equipment_average_epd": 0.73, + "electric_equipment_median_epd": 0.73, + "electric_equipment_maximum_epd": 0.73, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "storage < 50 sf - hospital", + "electric_equipment_minimum_epd": 0, + "electric_equipment_average_epd": 0, + "electric_equipment_median_epd": 0, + "electric_equipment_maximum_epd": 0, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "storage 50 to 1000 sf - hospital", + "electric_equipment_minimum_epd": 0, + "electric_equipment_average_epd": 0, + "electric_equipment_median_epd": 0, + "electric_equipment_maximum_epd": 0, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "guest room", + "electric_equipment_minimum_epd": 0.47, + "electric_equipment_average_epd": 0.53, + "electric_equipment_median_epd": 0.53, + "electric_equipment_maximum_epd": 0.58, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "lobby - hotel", + "electric_equipment_minimum_epd": 0.5, + "electric_equipment_average_epd": 0.5, + "electric_equipment_median_epd": 0.5, + "electric_equipment_maximum_epd": 0.5, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "library - cataloging", + "electric_equipment_minimum_epd": 0.21, + "electric_equipment_average_epd": 0.21, + "electric_equipment_median_epd": 0.21, + "electric_equipment_maximum_epd": 0.21, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "museum exhibit area", + "electric_equipment_minimum_epd": 0.32, + "electric_equipment_average_epd": 0.46, + "electric_equipment_median_epd": 0.43, + "electric_equipment_maximum_epd": 0.68, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "corridor - manufacturing facility", + "electric_equipment_minimum_epd": 0.38, + "electric_equipment_average_epd": 0.38, + "electric_equipment_median_epd": 0.38, + "electric_equipment_maximum_epd": 0.38, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "manufacturing equipment room", + "electric_equipment_minimum_epd": 0, + "electric_equipment_average_epd": 0, + "electric_equipment_median_epd": 0, + "electric_equipment_maximum_epd": 0, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "manufacturing low bay", + "electric_equipment_minimum_epd": 0.67, + "electric_equipment_average_epd": 0.67, + "electric_equipment_median_epd": 0.67, + "electric_equipment_maximum_epd": 0.67, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "performing arts dressing room", + "electric_equipment_minimum_epd": 0.29, + "electric_equipment_average_epd": 0.41, + "electric_equipment_median_epd": 0.43, + "electric_equipment_maximum_epd": 0.5, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "audience seating - auditorium", + "electric_equipment_minimum_epd": 0.26, + "electric_equipment_average_epd": 0.29, + "electric_equipment_median_epd": 0.29, + "electric_equipment_maximum_epd": 0.32, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "audience seating - motion picture theater", + "electric_equipment_minimum_epd": 0.28, + "electric_equipment_average_epd": 0.28, + "electric_equipment_median_epd": 0.28, + "electric_equipment_maximum_epd": 0.28, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "lobby - motion picture theater", + "electric_equipment_minimum_epd": 0.33, + "electric_equipment_average_epd": 0.33, + "electric_equipment_median_epd": 0.33, + "electric_equipment_maximum_epd": 0.33, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "Dwelling Unit", + "electric_equipment_minimum_epd": 0.25, + "electric_equipment_average_epd": 0.25, + "electric_equipment_median_epd": 0.25, + "electric_equipment_maximum_epd": 0.25, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "museum restoration", + "electric_equipment_minimum_epd": 0.21, + "electric_equipment_average_epd": 0.21, + "electric_equipment_median_epd": 0.21, + "electric_equipment_maximum_epd": 0.21, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "banking activity", + "electric_equipment_minimum_epd": 0.54, + "electric_equipment_average_epd": 0.55, + "electric_equipment_median_epd": 0.55, + "electric_equipment_maximum_epd": 0.56, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "warehouse - fine storage", + "electric_equipment_minimum_epd": 0, + "electric_equipment_average_epd": 0.06, + "electric_equipment_median_epd": 0.06, + "electric_equipment_maximum_epd": 0.12, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "classroom/lecture/training - penitentiary", + "electric_equipment_minimum_epd": 0.41, + "electric_equipment_average_epd": 0.41, + "electric_equipment_median_epd": 0.41, + "electric_equipment_maximum_epd": 0.41, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "dining - penitentiary", + "electric_equipment_minimum_epd": 0.35, + "electric_equipment_average_epd": 0.35, + "electric_equipment_median_epd": 0.35, + "electric_equipment_maximum_epd": 0.35, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "audience seating - performing arts theater", + "electric_equipment_minimum_epd": 0.27, + "electric_equipment_average_epd": 0.27, + "electric_equipment_median_epd": 0.27, + "electric_equipment_maximum_epd": 0.27, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "lobby - performing arts theater", + "electric_equipment_minimum_epd": 0.33, + "electric_equipment_average_epd": 0.33, + "electric_equipment_median_epd": 0.33, + "electric_equipment_maximum_epd": 0.33, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "audience seating - religious facility", + "electric_equipment_minimum_epd": 0.41, + "electric_equipment_average_epd": 0.41, + "electric_equipment_median_epd": 0.41, + "electric_equipment_maximum_epd": 0.41, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "worship/pulpit/choir area", + "electric_equipment_minimum_epd": 0.42, + "electric_equipment_average_epd": 0.42, + "electric_equipment_median_epd": 0.42, + "electric_equipment_maximum_epd": 0.42, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "classroom/lecture/training - preschool to 12th", + "electric_equipment_minimum_epd": 0.67, + "electric_equipment_average_epd": 0.67, + "electric_equipment_median_epd": 0.67, + "electric_equipment_maximum_epd": 0.67, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "sports arena playing area, class II", + "electric_equipment_minimum_epd": 0.32, + "electric_equipment_average_epd": 0.48, + "electric_equipment_median_epd": 0.48, + "electric_equipment_maximum_epd": 0.64, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "audience seating - sports arena", + "electric_equipment_minimum_epd": 0.38, + "electric_equipment_average_epd": 0.38, + "electric_equipment_median_epd": 0.38, + "electric_equipment_maximum_epd": 0.38, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "airport concourse", + "electric_equipment_minimum_epd": 0.52, + "electric_equipment_average_epd": 0.52, + "electric_equipment_median_epd": 0.52, + "electric_equipment_maximum_epd": 0.52, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "atrium < 20 ft height", + "electric_equipment_minimum_epd": 0.53, + "electric_equipment_average_epd": 0.53, + "electric_equipment_median_epd": 0.53, + "electric_equipment_maximum_epd": 0.53, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "atrium > 40 ft height", + "electric_equipment_minimum_epd": 0.53, + "electric_equipment_average_epd": 0.53, + "electric_equipment_median_epd": 0.53, + "electric_equipment_maximum_epd": 0.53, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "atrium >= 20 ft and <= 40 ft in height", + "electric_equipment_minimum_epd": 0.53, + "electric_equipment_average_epd": 0.53, + "electric_equipment_median_epd": 0.53, + "electric_equipment_maximum_epd": 0.53, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "baggage/carousel", + "electric_equipment_minimum_epd": 0.55, + "electric_equipment_average_epd": 0.55, + "electric_equipment_median_epd": 0.55, + "electric_equipment_maximum_epd": 0.55, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "seating area, general", + "electric_equipment_minimum_epd": 0.25, + "electric_equipment_average_epd": 0.25, + "electric_equipment_median_epd": 0.25, + "electric_equipment_maximum_epd": 0.25, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "transportation ticket counter", + "electric_equipment_minimum_epd": 0.74, + "electric_equipment_average_epd": 0.74, + "electric_equipment_median_epd": 0.74, + "electric_equipment_maximum_epd": 0.74, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "warehouse - bulk storage", + "electric_equipment_minimum_epd": 0.11, + "electric_equipment_average_epd": 0.11, + "electric_equipment_median_epd": 0.11, + "electric_equipment_maximum_epd": 0.11, + "electric_equipment_epd_unit": "W/ft2" + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/level_2_lighting_space_types.json b/data/openstudio_standards_data/database_files/level_2_lighting_space_types.json new file mode 100644 index 0000000000..653f4d6452 --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_2_lighting_space_types.json @@ -0,0 +1,1432 @@ +[ + { + "lighting_space_type_name": "bam_automotive_facility", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 1 + }, + { + "lighting_space_type_name": "bam_convention_center", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 2 + }, + { + "lighting_space_type_name": "bam_courthouse", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 3 + }, + { + "lighting_space_type_name": "bam_dinin_bar_lounge_leisure", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 4 + }, + { + "lighting_space_type_name": "bam_dining_cafeteria_fast_food", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 5 + }, + { + "lighting_space_type_name": "bam_dining_family", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 6 + }, + { + "lighting_space_type_name": "bam_dormitory", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 7 + }, + { + "lighting_space_type_name": "bam_exercise_center", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 8 + }, + { + "lighting_space_type_name": "bam_fire_station", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 23 + }, + { + "lighting_space_type_name": "bam_gymnasium", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 9 + }, + { + "lighting_space_type_name": "bam_healthcare_clinic", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 10 + }, + { + "lighting_space_type_name": "bam_hospital", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 11 + }, + { + "lighting_space_type_name": "bam_hotel", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 12 + }, + { + "lighting_space_type_name": "bam_library", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 13 + }, + { + "lighting_space_type_name": "bam_manufacturing_facility", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 14 + }, + { + "lighting_space_type_name": "bam_motel", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 15 + }, + { + "lighting_space_type_name": "bam_motion_picture_theater", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 16 + }, + { + "lighting_space_type_name": "bam_multifamily", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 17 + }, + { + "lighting_space_type_name": "bam_museum", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 18 + }, + { + "lighting_space_type_name": "bam_office", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 19 + }, + { + "lighting_space_type_name": "bam_parking_garage", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 20 + }, + { + "lighting_space_type_name": "bam_penitentiary", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 21 + }, + { + "lighting_space_type_name": "bam_performing_arts_theater", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 22 + }, + { + "lighting_space_type_name": "bam_police_station", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 23 + }, + { + "lighting_space_type_name": "bam_post_office", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 24 + }, + { + "lighting_space_type_name": "bam_religious_facility", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 25 + }, + { + "lighting_space_type_name": "bam_retail", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 26 + }, + { + "lighting_space_type_name": "bam_school_university", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 27 + }, + { + "lighting_space_type_name": "bam_sports_arena", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 28 + }, + { + "lighting_space_type_name": "bam_town_hall", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 29 + }, + { + "lighting_space_type_name": "bam_transportation", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 30 + }, + { + "lighting_space_type_name": "bam_warehouse", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 31 + }, + { + "lighting_space_type_name": "bam_workshop", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 32 + }, + { + "lighting_space_type_name": "office_enclosed_small", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 33 + }, + { + "lighting_space_type_name": "office_enclosed_large", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 33 + }, + { + "lighting_space_type_name": "office_open", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 34 + }, + { + "lighting_space_type_name": "conference_meeting_multipurpose", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 35 + }, + { + "lighting_space_type_name": "classroom_lecture_training_general", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 36 + }, + { + "lighting_space_type_name": "classroom_lecture_training_penitentiary", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 37 + }, + { + "lighting_space_type_name": "lobby_general", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 38 + }, + { + "lighting_space_type_name": "lobby_hotel", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 39 + }, + { + "lighting_space_type_name": "lobby_performing_arts_theater", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 40 + }, + { + "lighting_space_type_name": "lobby_motion_picture_theater", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 41 + }, + { + "lighting_space_type_name": "lobby_visually_impaired", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 38 + }, + { + "lighting_space_type_name": "lobby_elevator", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 38 + }, + { + "lighting_space_type_name": "audience_seating_general", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 42 + }, + { + "lighting_space_type_name": "audience_seating_gymnasium", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 43 + }, + { + "lighting_space_type_name": "audience_seating_exercise_center", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 44 + }, + { + "lighting_space_type_name": "audience_seating_convention_center", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 45 + }, + { + "lighting_space_type_name": "audience_seating_penitentiary", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 46 + }, + { + "lighting_space_type_name": "audience_seating_religious_facility", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 47 + }, + { + "lighting_space_type_name": "audience_seating_sports_arena", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 48 + }, + { + "lighting_space_type_name": "audience_seating_performing_arts_theater", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 49 + }, + { + "lighting_space_type_name": "audience_seating_motion_picture_theater", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 50 + }, + { + "lighting_space_type_name": "audience_seating_transportation", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 51 + }, + { + "lighting_space_type_name": "audience_seating_auditorium", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 42 + }, + { + "lighting_space_type_name": "atrium_first_three_floor", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 52 + }, + { + "lighting_space_type_name": "atrium_each_additional_floor", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 53 + }, + { + "lighting_space_type_name": "lounge_breakroom_general", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 54 + }, + { + "lighting_space_type_name": "lounge_breakroom_healthcare_facility", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 55 + }, + { + "lighting_space_type_name": "dining_general", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 56 + }, + { + "lighting_space_type_name": "dining_penitentiary", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 57 + }, + { + "lighting_space_type_name": "dining_hotel", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 58 + }, + { + "lighting_space_type_name": "dining_motel", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 59 + }, + { + "lighting_space_type_name": "dining_bar_lounge_leisure", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 60 + }, + { + "lighting_space_type_name": "dining_family", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 61 + }, + { + "lighting_space_type_name": "dining_cafeteria_fast_food", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 56 + }, + { + "lighting_space_type_name": "dining_visually_impaired", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 56 + }, + { + "lighting_space_type_name": "kitchen", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 62 + }, + { + "lighting_space_type_name": "laboratory_classroom", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 63 + }, + { + "lighting_space_type_name": "laboratory_all_other", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 63 + }, + { + "lighting_space_type_name": "restroom_visually_impaired", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 64 + }, + { + "lighting_space_type_name": "restroom_all_other", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 64 + }, + { + "lighting_space_type_name": "performing_arts_dressing_room", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 65 + }, + { + "lighting_space_type_name": "corridor_general", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 66 + }, + { + "lighting_space_type_name": "corridor_hospital", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 67 + }, + { + "lighting_space_type_name": "corridor_manufacturing_facility", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 68 + }, + { + "lighting_space_type_name": "corridor_visually_impaired", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 66 + }, + { + "lighting_space_type_name": "stairway", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 69 + }, + { + "lighting_space_type_name": "stairwell", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 69 + }, + { + "lighting_space_type_name": "storage_ all_other_small", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 70 + }, + { + "lighting_space_type_name": "storage_ all_other_large", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 70 + }, + { + "lighting_space_type_name": "storage_hospital_small", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 71 + }, + { + "lighting_space_type_name": "storage_hospital_large", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 71 + }, + { + "lighting_space_type_name": "storage_inactive", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 72 + }, + { + "lighting_space_type_name": "storage_inactive_museum", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 73 + }, + { + "lighting_space_type_name": "electrical_mechanical", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 74 + }, + { + "lighting_space_type_name": "workshop", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 75 + }, + { + "lighting_space_type_name": "gymnasium_playing_area", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 76 + }, + { + "lighting_space_type_name": "gymnasium_exercise_area", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 77 + }, + { + "lighting_space_type_name": "courtroom", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 78 + }, + { + "lighting_space_type_name": "confinement_cells", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 79 + }, + { + "lighting_space_type_name": "judges_chambers", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 80 + }, + { + "lighting_space_type_name": "emergency_vehicle_garage", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 81 + }, + { + "lighting_space_type_name": "firestation_sleeping_quarters", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 82 + }, + { + "lighting_space_type_name": "post_office_sorting_area", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 83 + }, + { + "lighting_space_type_name": "exhibit_convention_center", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 84 + }, + { + "lighting_space_type_name": "library_cataloging", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 85 + }, + { + "lighting_space_type_name": "library_stacks", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 86 + }, + { + "lighting_space_type_name": "library_reading", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 87 + }, + { + "lighting_space_type_name": "emergency_room", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 88 + }, + { + "lighting_space_type_name": "recovery", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 89 + }, + { + "lighting_space_type_name": "nurses_station", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 90 + }, + { + "lighting_space_type_name": "exam_treatment", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 91 + }, + { + "lighting_space_type_name": "pharmacy", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 92 + }, + { + "lighting_space_type_name": "patient_room", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 93 + }, + { + "lighting_space_type_name": "operating_room", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 94 + }, + { + "lighting_space_type_name": "nursery", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 95 + }, + { + "lighting_space_type_name": "medical_supply", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 96 + }, + { + "lighting_space_type_name": "physical_therapy", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 97 + }, + { + "lighting_space_type_name": "imaging", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 98 + }, + { + "lighting_space_type_name": "laundry_washing", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 99 + }, + { + "lighting_space_type_name": "automotive", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 100 + }, + { + "lighting_space_type_name": "manufacturing_low_bay", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 101 + }, + { + "lighting_space_type_name": "manufacturing_high_bay", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 102 + }, + { + "lighting_space_type_name": "detailed_manufacuring", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 103 + }, + { + "lighting_space_type_name": "manufacturing_equipment_room", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 104 + }, + { + "lighting_space_type_name": "manufacturing_control", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 105 + }, + { + "lighting_space_type_name": "guest_room", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 106 + }, + { + "lighting_space_type_name": "dormitory_living_quarters", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 107 + }, + { + "lighting_space_type_name": "museum_exhibit_area", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 108 + }, + { + "lighting_space_type_name": "museum_restoration", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 109 + }, + { + "lighting_space_type_name": "banking_activity", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 110 + }, + { + "lighting_space_type_name": "worship_pulpit_choir_area", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 111 + }, + { + "lighting_space_type_name": "fellowship_hall_religious_facility", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 112 + }, + { + "lighting_space_type_name": "sales", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 113 + }, + { + "lighting_space_type_name": "retail_mall_concourse", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 114 + }, + { + "lighting_space_type_name": "sports_arena_ring_sports_area", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 115 + }, + { + "lighting_space_type_name": "sports_arena_court_sports_area", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 116 + }, + { + "lighting_space_type_name": "sports_arena_indoor_playing_field", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 117 + }, + { + "lighting_space_type_name": "warehouse_bulk_storage", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 119 + }, + { + "lighting_space_type_name": "parking_area_interior", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 120 + }, + { + "lighting_space_type_name": "airport_concourse", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 121 + }, + { + "lighting_space_type_name": "baggage_carousel", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 122 + }, + { + "lighting_space_type_name": "transportation_ticket_counter", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 123 + }, + { + "lighting_space_type_name": "sales_display_type_1", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 124 + }, + { + "lighting_space_type_name": "sales_display_type_2", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 124 + }, + { + "lighting_space_type_name": "sales_display_type_3", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 125 + }, + { + "lighting_space_type_name": "sales_display_type_4", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_defintion_id": 125 + }, + { + "lighting_space_type_name": "bam_automotive_facility", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 1 + }, + { + "lighting_space_type_name": "bam_convention_center", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 2 + }, + { + "lighting_space_type_name": "bam_courthouse", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 3 + }, + { + "lighting_space_type_name": "bam_dinin_bar_lounge_leisure", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 4 + }, + { + "lighting_space_type_name": "bam_dining_cafeteria_fast_food", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 5 + }, + { + "lighting_space_type_name": "bam_dining_family", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 6 + }, + { + "lighting_space_type_name": "bam_dormitory", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 7 + }, + { + "lighting_space_type_name": "bam_exercise_center", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 8 + }, + { + "lighting_space_type_name": "bam_fire_station", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 9 + }, + { + "lighting_space_type_name": "bam_gymnasium", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 10 + }, + { + "lighting_space_type_name": "bam_healthcare_clinic", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 11 + }, + { + "lighting_space_type_name": "bam_hospital", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 12 + }, + { + "lighting_space_type_name": "bam_hotel", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 13 + }, + { + "lighting_space_type_name": "bam_library", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 14 + }, + { + "lighting_space_type_name": "bam_manufacturing_facility", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 15 + }, + { + "lighting_space_type_name": "bam_motel", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 13 + }, + { + "lighting_space_type_name": "bam_motion_picture_theater", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 16 + }, + { + "lighting_space_type_name": "bam_multifamily", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 17 + }, + { + "lighting_space_type_name": "bam_museum", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 18 + }, + { + "lighting_space_type_name": "bam_office", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 19 + }, + { + "lighting_space_type_name": "bam_parking_garage", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 20 + }, + { + "lighting_space_type_name": "bam_penitentiary", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 21 + }, + { + "lighting_space_type_name": "bam_performing_arts_theater", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 22 + }, + { + "lighting_space_type_name": "bam_police_station", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 23 + }, + { + "lighting_space_type_name": "bam_post_office", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 24 + }, + { + "lighting_space_type_name": "bam_religious_facility", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 25 + }, + { + "lighting_space_type_name": "bam_retail", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 26 + }, + { + "lighting_space_type_name": "bam_school_university", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 27 + }, + { + "lighting_space_type_name": "bam_sports_arena", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 28 + }, + { + "lighting_space_type_name": "bam_town_hall", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 29 + }, + { + "lighting_space_type_name": "bam_transportation", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 30 + }, + { + "lighting_space_type_name": "bam_warehouse", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 31 + }, + { + "lighting_space_type_name": "bam_workshop", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 32 + }, + { + "lighting_space_type_name": "office_enclosed_small", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 79 + }, + { + "lighting_space_type_name": "office_enclosed_large", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 80 + }, + { + "lighting_space_type_name": "office_open", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 81 + }, + { + "lighting_space_type_name": "conference_meeting_multipurpose", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 48 + }, + { + "lighting_space_type_name": "classroom_lecture_training_general", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 47 + }, + { + "lighting_space_type_name": "classroom_lecture_training_penitentiary", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 46 + }, + { + "lighting_space_type_name": "lobby_general", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 75 + }, + { + "lighting_space_type_name": "lobby_hotel", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 72 + }, + { + "lighting_space_type_name": "lobby_performing_arts_theater", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 74 + }, + { + "lighting_space_type_name": "lobby_motion_picture_theater", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 73 + }, + { + "lighting_space_type_name": "lobby_visually_impaired", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 70 + }, + { + "lighting_space_type_name": "lobby_elevator", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 71 + }, + { + "lighting_space_type_name": "audience_seating_general", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 43 + }, + { + "lighting_space_type_name": "audience_seating_gymnasium", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 37 + }, + { + "lighting_space_type_name": "audience_seating_exercise_center", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 43 + }, + { + "lighting_space_type_name": "audience_seating_convention_center", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 43 + }, + { + "lighting_space_type_name": "audience_seating_penitentiary", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 39 + }, + { + "lighting_space_type_name": "audience_seating_religious_facility", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 41 + }, + { + "lighting_space_type_name": "audience_seating_sports_arena", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 42 + }, + { + "lighting_space_type_name": "audience_seating_performing_arts_theater", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 40 + }, + { + "lighting_space_type_name": "audience_seating_motion_picture_theater", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 38 + }, + { + "lighting_space_type_name": "audience_seating_transportation", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 43 + }, + { + "lighting_space_type_name": "audience_seating_auditorium", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 36 + }, + { + "lighting_space_type_name": "atrium_low", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 33 + }, + { + "lighting_space_type_name": "atrium_medium", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 34 + }, + { + "lighting_space_type_name": "atrium_high", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 35 + }, + { + "lighting_space_type_name": "lounge_breakroom_general", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 78 + }, + { + "lighting_space_type_name": "lounge_breakroom_healthcare_facility", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 77 + }, + { + "lighting_space_type_name": "dining_general", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 61 + }, + { + "lighting_space_type_name": "dining_penitentiary", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 56 + }, + { + "lighting_space_type_name": "dining_hotel", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 61 + }, + { + "lighting_space_type_name": "dining_motel", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 61 + }, + { + "lighting_space_type_name": "dining_bar_lounge_leisure", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 58 + }, + { + "lighting_space_type_name": "dining_family", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 60 + }, + { + "lighting_space_type_name": "dining_cafeteria_fast_food", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 59 + }, + { + "lighting_space_type_name": "dining_visually_impaired", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 57 + }, + { + "lighting_space_type_name": "kitchen", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 64 + }, + { + "lighting_space_type_name": "laboratory_classroom", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 66 + }, + { + "lighting_space_type_name": "laboratory_all_other", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 67 + }, + { + "lighting_space_type_name": "restroom_visually_impaired", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 84 + }, + { + "lighting_space_type_name": "restroom_all_other", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 85 + }, + { + "lighting_space_type_name": "performing_arts_dressing_room", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 120 + }, + { + "lighting_space_type_name": "corridor_general", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 53 + }, + { + "lighting_space_type_name": "corridor_hospital", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 52 + }, + { + "lighting_space_type_name": "corridor_manufacturing_facility", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 53 + }, + { + "lighting_space_type_name": "corridor_visually_impaired", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 51 + }, + { + "lighting_space_type_name": "stairway", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 88 + }, + { + "lighting_space_type_name": "stairwell", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 89 + }, + { + "lighting_space_type_name": "storage_ all_other_small", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 90 + }, + { + "lighting_space_type_name": "storage_ all_other_large", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 91 + }, + { + "lighting_space_type_name": "storage_hospital_small", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 90 + }, + { + "lighting_space_type_name": "storage_hospital_large", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 91 + }, + { + "lighting_space_type_name": "electrical_mechanical", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 62 + }, + { + "lighting_space_type_name": "workshop", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 93 + }, + { + "lighting_space_type_name": "gymnasium_playing_area", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 101 + }, + { + "lighting_space_type_name": "gymnasium_exercise_area", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 100 + }, + { + "lighting_space_type_name": "courtroom", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 54 + }, + { + "lighting_space_type_name": "confinement_cells", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 49 + }, + { + "lighting_space_type_name": "emergency_vehicle_garage", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 63 + }, + { + "lighting_space_type_name": "firestation_sleeping_quarters", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 99 + }, + { + "lighting_space_type_name": "post_office_sorting_area", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 121 + }, + { + "lighting_space_type_name": "exhibit_convention_center", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 97 + }, + { + "lighting_space_type_name": "library_stacks", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 112 + }, + { + "lighting_space_type_name": "library_reading", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 111 + }, + { + "lighting_space_type_name": "recovery", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 110 + }, + { + "lighting_space_type_name": "nurses_station", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 106 + }, + { + "lighting_space_type_name": "exam_treatment", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 102 + }, + { + "lighting_space_type_name": "pharmacy", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 83 + }, + { + "lighting_space_type_name": "patient_room", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 108 + }, + { + "lighting_space_type_name": "operating_room", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 107 + }, + { + "lighting_space_type_name": "nursery", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 105 + }, + { + "lighting_space_type_name": "medical_supply", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 104 + }, + { + "lighting_space_type_name": "physical_therapy", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 109 + }, + { + "lighting_space_type_name": "imaging", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 103 + }, + { + "lighting_space_type_name": "laundry_washing", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 68 + }, + { + "lighting_space_type_name": "automotive", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 96 + }, + { + "lighting_space_type_name": "manufacturing_low_bay", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 117 + }, + { + "lighting_space_type_name": "manufacturing_high_bay", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 116 + }, + { + "lighting_space_type_name": "detailed_manufacuring", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 113 + }, + { + "lighting_space_type_name": "manufacturing_equipment_room", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 114 + }, + { + "lighting_space_type_name": "manufacturing_extra_high_bay", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 115 + }, + { + "lighting_space_type_name": "guest_room", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 65 + }, + { + "lighting_space_type_name": "dormitory_living_quarters", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 98 + }, + { + "lighting_space_type_name": "museum_exhibit_area", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 118 + }, + { + "lighting_space_type_name": "museum_restoration", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 119 + }, + { + "lighting_space_type_name": "banking_activity", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 44 + }, + { + "lighting_space_type_name": "worship_pulpit_choir_area", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 123 + }, + { + "lighting_space_type_name": "fellowship_hall_religious_facility", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 122 + }, + { + "lighting_space_type_name": "sales", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 86 + }, + { + "lighting_space_type_name": "retail_mall_concourse", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 125 + }, + { + "lighting_space_type_name": "retail_dressing_room", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 124 + }, + { + "lighting_space_type_name": "sports_arena_playing_area_class_I", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 126 + }, + { + "lighting_space_type_name": "sports_arena_playing_area_class_II", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 127 + }, + { + "lighting_space_type_name": "sports_arena_playing_area_class_III", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 128 + }, + { + "lighting_space_type_name": "sports_arena_playing_area_class_IV", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 129 + }, + { + "lighting_space_type_name": "warehouse_fine_storage", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 134 + }, + { + "lighting_space_type_name": "warehouse_bulk_storage", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 133 + }, + { + "lighting_space_type_name": "parking_area_interior", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 82 + }, + { + "lighting_space_type_name": "airport_concourse", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 131 + }, + { + "lighting_space_type_name": "baggage_carousel", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 130 + }, + { + "lighting_space_type_name": "transportation_ticket_counter", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 132 + }, + { + "lighting_space_type_name": "sales_display_type_1", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 135 + }, + { + "lighting_space_type_name": "sales_display_type_2", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 136 + }, + { + "lighting_space_type_name": "sales_display_type_3", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 137 + }, + { + "lighting_space_type_name": "sales_display_type_4", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 138 + }, + { + "lighting_space_type_name": "breakroom", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 45 + }, + { + "lighting_space_type_name": "copy_print", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 50 + }, + { + "lighting_space_type_name": "computer_room", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 55 + }, + { + "lighting_space_type_name": "loading_dock", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 69 + }, + { + "lighting_space_type_name": "locker_room", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 76 + }, + { + "lighting_space_type_name": "seating_area_general", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 87 + }, + { + "lighting_space_type_name": "vehicular_maintenance", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 92 + }, + { + "lighting_space_type_name": "chapel_visually_impaired", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 94 + }, + { + "lighting_space_type_name": "recreation_common_living_visually_impaired", + "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_defintion_id": 95 + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.json b/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.json new file mode 100644 index 0000000000..47898183d4 --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.json @@ -0,0 +1,867 @@ +[ + { + "ventilation_space_type_name": "correctional_facilities_cell", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 13 + }, + { + "ventilation_space_type_name": "correctional_facilities_dayroom", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 14 + }, + { + "ventilation_space_type_name": "correctional_facilities_guard_stations", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 15 + }, + { + "ventilation_space_type_name": "correctional_facilities_booking_waiting", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 12 + }, + { + "ventilation_space_type_name": "educational_facilities_daycare", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 21 + }, + { + "ventilation_space_type_name": "educational_facilities_classroom_young", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 17 + }, + { + "ventilation_space_type_name": "educational_facilities_classroom_old", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 18 + }, + { + "ventilation_space_type_name": "educational_facilities_lecture_classroom", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 22 + }, + { + "ventilation_space_type_name": "educational_facilities_lecture_hall", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 23 + }, + { + "ventilation_space_type_name": "educational_facilities_art_classroom", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 16 + }, + { + "ventilation_space_type_name": "educational_facilities_science_laboratories", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 28 + }, + { + "ventilation_space_type_name": "educational_facilities_wood_metal_shop", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 30 + }, + { + "ventilation_space_type_name": "educational_facilities_computer_lab", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 19 + }, + { + "ventilation_space_type_name": "educational_facilities_media_center", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 25 + }, + { + "ventilation_space_type_name": "educational_facilities_music_theater_dance", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 27 + }, + { + "ventilation_space_type_name": "educational_facilities_multiuse_assembly", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 26 + }, + { + "ventilation_space_type_name": "educational_facilities_daycare_sickroom", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 20 + }, + { + "ventilation_space_type_name": "educational_facilities_libraries", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 24 + }, + { + "ventilation_space_type_name": "educational_facilities_university_college_laboratories", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 29 + }, + { + "ventilation_space_type_name": "food_beverage_service_restaurant_dining_rooms", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 34 + }, + { + "ventilation_space_type_name": "food_beverage_service_cafeteria_fast_food_dining", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 32 + }, + { + "ventilation_space_type_name": "food_beverage_service_bars_cocktail_lounges", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 31 + }, + { + "ventilation_space_type_name": "food_beverage_service_kitchen", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 33 + }, + { + "ventilation_space_type_name": "general_conference_meeting", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 37 + }, + { + "ventilation_space_type_name": "general_conference_corridors", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 38 + }, + { + "ventilation_space_type_name": "general_conference_storage_rooms", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 39 + }, + { + "ventilation_space_type_name": "general_break_rooms", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 35 + }, + { + "ventilation_space_type_name": "general_coffee_stations", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 36 + }, + { + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_bedroom_living_room", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 41 + }, + { + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_barracks_sleeping_areas", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 40 + }, + { + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_lobbies_prefunction", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 44 + }, + { + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_multi_purpose_assembly", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 45 + }, + { + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_laundry_rooms", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 42 + }, + { + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_laundry_rooms_w_dwelling_units", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 43 + }, + { + "ventilation_space_type_name": "office_buildings_office_space", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 62 + }, + { + "ventilation_space_type_name": "office_buildings_reception_areas", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 63 + }, + { + "ventilation_space_type_name": "office_buildings_telephone_data_entry", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 64 + }, + { + "ventilation_space_type_name": "office_buildings_main_entry_lobbies", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 60 + }, + { + "ventilation_space_type_name": "office_buildings_breakrooms", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 59 + }, + { + "ventilation_space_type_name": "office_buildings_occupiable_storage_rooms", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 61 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_bank_ vaults_safe_deposit", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 47 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_computer", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 48 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_pharmacy", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 52 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_photo_studios", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 53 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_shipping_receiving", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 54 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_transportation_waiting", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 57 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_warehouses", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 58 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_banks_bank_lobbies", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 46 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_freezer_refrigerated_spaces", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 49 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 50 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_w_hazardous_materials", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 51 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_sorting_packing_light_assembly", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 55 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_telephone_closets", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 56 + }, + { + "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 83 + }, + { + "ventilation_space_type_name": "public_assembly_spaces_religious_workshop", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 90 + }, + { + "ventilation_space_type_name": "public_assembly_spaces_courtrooms", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 84 + }, + { + "ventilation_space_type_name": "public_assembly_spaces_legislative_chambers", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 85 + }, + { + "ventilation_space_type_name": "public_assembly_spaces_libraries", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 86 + }, + { + "ventilation_space_type_name": "public_assembly_spaces_lobbies", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 87 + }, + { + "ventilation_space_type_name": "public_assembly_spaces_children_museums", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 88 + }, + { + "ventilation_space_type_name": "public_assembly_spaces_museums_galleries", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 89 + }, + { + "ventilation_space_type_name": "retail_sales", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 91 + }, + { + "ventilation_space_type_name": "retail_mall_common_areas", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 95 + }, + { + "ventilation_space_type_name": "retail_barbershop", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 92 + }, + { + "ventilation_space_type_name": "retail_beauty_nail_salons", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 93 + }, + { + "ventilation_space_type_name": "retail_pet_shops", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 96 + }, + { + "ventilation_space_type_name": "retail_supermarket", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 97 + }, + { + "ventilation_space_type_name": "retail_coin_operated_laundries", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 94 + }, + { + "ventilation_space_type_name": "sports_entertainment_sports_arena", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 102 + }, + { + "ventilation_space_type_name": "sports_entertainment_gym_stadium", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 102 + }, + { + "ventilation_space_type_name": "sports_entertainment_spectator_areas", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 105 + }, + { + "ventilation_space_type_name": "sports_entertainment_swimming", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 107 + }, + { + "ventilation_space_type_name": "sports_entertainment_disco_dance_floors", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 99 + }, + { + "ventilation_space_type_name": "sports_entertainment_health_club_aerobics_room", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 103 + }, + { + "ventilation_space_type_name": "sports_entertainment_health_club_weight_rooms", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 104 + }, + { + "ventilation_space_type_name": "sports_entertainment_bowling_alley", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 98 + }, + { + "ventilation_space_type_name": "sports_entertainment_gambling_casinos", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 100 + }, + { + "ventilation_space_type_name": "sports_entertainment_game_arcades", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 101 + }, + { + "ventilation_space_type_name": "sports_entertainment_stages_studios", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 106 + }, + { + "ventilation_space_type_name": "animal_facilities_animal_exam_room", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 1 + }, + { + "ventilation_space_type_name": "animal_facilities_animal_imaging", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 2 + }, + { + "ventilation_space_type_name": "animal_facilities_animal_operating_rooms", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 3 + }, + { + "ventilation_space_type_name": "animal_facilities_animal_postoperative_recovery_room", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 4 + }, + { + "ventilation_space_type_name": "animal_facilities_animal_preparation_rooms", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 5 + }, + { + "ventilation_space_type_name": "animal_facilities_animal_procedure_room", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 6 + }, + { + "ventilation_space_type_name": "animal_facilities_animal_surgery_scrub", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 7 + }, + { + "ventilation_space_type_name": "animal_facilities_large_animal_holding_room", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 8 + }, + { + "ventilation_space_type_name": "animal_facilities_necropsy", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 9 + }, + { + "ventilation_space_type_name": "animal_facilities_small_animal_cage_room_static", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 10 + }, + { + "ventilation_space_type_name": "animal_facilities_small_animal_cage_room_ventilated", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 11 + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_birthing_room", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 65 + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_class_1_imaging_rooms", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 66 + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_dental_operatory", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 67 + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_general_examination_room", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 68 + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_other_dental_treatment_areas", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 69 + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_physical_therapy_exercise_area", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 70 + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_physical_therapy_individual_room", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 71 + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_physical_therapeutic_pool_area", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 72 + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_prosthetics_orthotics_room", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 73 + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_psychiatric_consultation_room", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 74 + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_psychiatric_examination_room", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 75 + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_psychiatric_group_room", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 76 + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_psychiatric_seclusion_room", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 77 + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_speech_therapy_room", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 78 + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_urgent_care_examination_room", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 79 + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_urgent_care_observation_room", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 80 + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_urgent_care_treatment_room", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 81 + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_urgent_care_triage_room", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 82 + }, + { + "ventilation_space_type_name": "transient_residential_common_corridors", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 108 + }, + { + "ventilation_space_type_name": "transient_residential_dwelling_unit", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_defintion_id": 109 + }, + { + "ventilation_space_type_name": "correctional_facilities_cell", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 1 + }, + { + "ventilation_space_type_name": "correctional_facilities_dayroom", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 2 + }, + { + "ventilation_space_type_name": "correctional_facilities_guard_stations", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 3 + }, + { + "ventilation_space_type_name": "correctional_facilities_booking_waiting", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 4 + }, + { + "ventilation_space_type_name": "educational_facilities_daycare", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 5 + }, + { + "ventilation_space_type_name": "educational_facilities_classroom_young", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 6 + }, + { + "ventilation_space_type_name": "educational_facilities_classroom_old", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 7 + }, + { + "ventilation_space_type_name": "educational_facilities_lecture_classroom", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 8 + }, + { + "ventilation_space_type_name": "educational_facilities_lecture_hall", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 9 + }, + { + "ventilation_space_type_name": "educational_facilities_art_classroom", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 10 + }, + { + "ventilation_space_type_name": "educational_facilities_science_laboratories", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 11 + }, + { + "ventilation_space_type_name": "educational_facilities_wood_metal_shop", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 12 + }, + { + "ventilation_space_type_name": "educational_facilities_computer_lab", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 13 + }, + { + "ventilation_space_type_name": "educational_facilities_media_center", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 14 + }, + { + "ventilation_space_type_name": "educational_facilities_music_theater_dance", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 15 + }, + { + "ventilation_space_type_name": "educational_facilities_multiuse_assembly", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 16 + }, + { + "ventilation_space_type_name": "food_beverage_service_restaurant_dining_rooms", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 17 + }, + { + "ventilation_space_type_name": "food_beverage_service_cafeteria_fast_food_dining", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 18 + }, + { + "ventilation_space_type_name": "food_beverage_service_bars_cocktail_lounges", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 19 + }, + { + "ventilation_space_type_name": "general_conference_meeting", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 20 + }, + { + "ventilation_space_type_name": "general_conference_corridors", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 21 + }, + { + "ventilation_space_type_name": "general_conference_storage_rooms", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 22 + }, + { + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_bedroom_living_room", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 23 + }, + { + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_barracks_sleeping_areas", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 24 + }, + { + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_lobbies_prefunction", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 25 + }, + { + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_multi_purpose_assembly", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 26 + }, + { + "ventilation_space_type_name": "office_buildings_office_space", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 27 + }, + { + "ventilation_space_type_name": "office_buildings_reception_areas", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 28 + }, + { + "ventilation_space_type_name": "office_buildings_telephone_data_entry", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 29 + }, + { + "ventilation_space_type_name": "office_buildings_main_entry_lobbies", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 30 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_bank_ vaults_safe_deposit", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 31 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_computer", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 32 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_pharmacy", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 33 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_photo_studios", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 34 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_shipping_receiving", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 35 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_transportation_waiting", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 36 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_warehouses", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 37 + }, + { + "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 38 + }, + { + "ventilation_space_type_name": "public_assembly_spaces_religious_workshop", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 39 + }, + { + "ventilation_space_type_name": "public_assembly_spaces_courtrooms", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 40 + }, + { + "ventilation_space_type_name": "public_assembly_spaces_legislative_chambers", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 41 + }, + { + "ventilation_space_type_name": "public_assembly_spaces_libraries", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 42 + }, + { + "ventilation_space_type_name": "public_assembly_spaces_lobbies", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 43 + }, + { + "ventilation_space_type_name": "public_assembly_spaces_children_museums", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 44 + }, + { + "ventilation_space_type_name": "public_assembly_spaces_museums_galleries", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 45 + }, + { + "ventilation_space_type_name": "retail_sales", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 46 + }, + { + "ventilation_space_type_name": "retail_mall_common_areas", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 47 + }, + { + "ventilation_space_type_name": "retail_barbershop", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 48 + }, + { + "ventilation_space_type_name": "retail_beauty_nail_salons", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 49 + }, + { + "ventilation_space_type_name": "retail_pet_shops", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 50 + }, + { + "ventilation_space_type_name": "retail_supermarket", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 51 + }, + { + "ventilation_space_type_name": "retail_coin_operated_laundries", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 52 + }, + { + "ventilation_space_type_name": "sports_entertainment_sports_arena", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 53 + }, + { + "ventilation_space_type_name": "sports_entertainment_gym_stadium", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 54 + }, + { + "ventilation_space_type_name": "sports_entertainment_spectator_areas", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 55 + }, + { + "ventilation_space_type_name": "sports_entertainment_swimming", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 56 + }, + { + "ventilation_space_type_name": "sports_entertainment_disco_dance_floors", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 57 + }, + { + "ventilation_space_type_name": "sports_entertainment_health_club_aerobics_room", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 58 + }, + { + "ventilation_space_type_name": "sports_entertainment_health_club_weight_rooms", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 59 + }, + { + "ventilation_space_type_name": "sports_entertainment_bowling_alley", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 60 + }, + { + "ventilation_space_type_name": "sports_entertainment_gambling_casinos", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 61 + }, + { + "ventilation_space_type_name": "sports_entertainment_game_arcades", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 62 + }, + { + "ventilation_space_type_name": "sports_entertainment_stages_studios", + "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_defintion_id": 63 + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/initial_data/light_def_90_1_2004.json b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2004.json similarity index 90% rename from data/openstudio_standards_data/initial_data/light_def_90_1_2004.json rename to data/openstudio_standards_data/database_files/level_3_lighting_90_1_2004.json index 6530823f03..453e12a0d5 100644 --- a/data/openstudio_standards_data/initial_data/light_def_90_1_2004.json +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2004.json @@ -1,6 +1,5 @@ [ { - "id": 1, "method": "BA", "lighting_primary_space_type": "Automotive Facility", "lighting_per_area": 0.9, @@ -9,7 +8,6 @@ "annotation": "" }, { - "id": 2, "method": "BA", "lighting_primary_space_type": "Convention Center", "lighting_per_area": 1.2, @@ -18,7 +16,6 @@ "annotation": "" }, { - "id": 3, "method": "BA", "lighting_primary_space_type": "Court House", "lighting_per_area": 1.2, @@ -27,7 +24,6 @@ "annotation": "" }, { - "id": 4, "method": "BA", "lighting_primary_space_type": "Dining: Bar Lounge/Leisure", "lighting_per_area": 1.3, @@ -36,7 +32,6 @@ "annotation": "" }, { - "id": 5, "method": "BA", "lighting_primary_space_type": "Dining: Cafeteria/Fast Food", "lighting_per_area": 1.4, @@ -45,7 +40,6 @@ "annotation": "" }, { - "id": 6, "method": "BA", "lighting_primary_space_type": "Dining: Family", "lighting_per_area": 1.6, @@ -54,7 +48,6 @@ "annotation": "" }, { - "id": 7, "method": "BA", "lighting_primary_space_type": "Dormitory", "lighting_per_area": 1, @@ -63,7 +56,6 @@ "annotation": "" }, { - "id": 8, "method": "BA", "lighting_primary_space_type": "Exercise Center", "lighting_per_area": 1, @@ -72,7 +64,6 @@ "annotation": "" }, { - "id": 9, "method": "BA", "lighting_primary_space_type": "Gymnasium", "lighting_per_area": 1.1, @@ -81,7 +72,6 @@ "annotation": "" }, { - "id": 10, "method": "BA", "lighting_primary_space_type": "Health Care-Clinic", "lighting_per_area": 1, @@ -90,7 +80,6 @@ "annotation": "" }, { - "id": 11, "method": "BA", "lighting_primary_space_type": "Hospital", "lighting_per_area": 1.2, @@ -99,7 +88,6 @@ "annotation": "" }, { - "id": 12, "method": "BA", "lighting_primary_space_type": "Hotel", "lighting_per_area": 1, @@ -108,7 +96,6 @@ "annotation": "" }, { - "id": 13, "method": "BA", "lighting_primary_space_type": "Library", "lighting_per_area": 1.3, @@ -117,7 +104,6 @@ "annotation": "" }, { - "id": 14, "method": "BA", "lighting_primary_space_type": "Manufacturing Facility", "lighting_per_area": 1.3, @@ -126,7 +112,6 @@ "annotation": "" }, { - "id": 15, "method": "BA", "lighting_primary_space_type": "Motel", "lighting_per_area": 1, @@ -135,7 +120,6 @@ "annotation": "" }, { - "id": 16, "method": "BA", "lighting_primary_space_type": "Motion Picture Theater", "lighting_per_area": 1.2, @@ -144,7 +128,6 @@ "annotation": "" }, { - "id": 17, "method": "BA", "lighting_primary_space_type": "Multi-Family", "lighting_per_area": 0.7, @@ -153,7 +136,6 @@ "annotation": "" }, { - "id": 18, "method": "BA", "lighting_primary_space_type": "Museum", "lighting_per_area": 1.1, @@ -162,7 +144,6 @@ "annotation": "" }, { - "id": 19, "method": "BA", "lighting_primary_space_type": "Office", "lighting_per_area": 1, @@ -171,7 +152,6 @@ "annotation": "" }, { - "id": 20, "method": "BA", "lighting_primary_space_type": "Parking Garage", "lighting_per_area": 0.3, @@ -180,7 +160,6 @@ "annotation": "" }, { - "id": 21, "method": "BA", "lighting_primary_space_type": "Penitentiary", "lighting_per_area": 1, @@ -189,7 +168,6 @@ "annotation": "" }, { - "id": 22, "method": "BA", "lighting_primary_space_type": "Performing Arts Theater", "lighting_per_area": 1.6, @@ -198,7 +176,6 @@ "annotation": "" }, { - "id": 23, "method": "BA", "lighting_primary_space_type": "Police/Fire Station", "lighting_per_area": 1, @@ -207,7 +184,6 @@ "annotation": "" }, { - "id": 24, "method": "BA", "lighting_primary_space_type": "Post Office", "lighting_per_area": 1.1, @@ -216,7 +192,6 @@ "annotation": "" }, { - "id": 25, "method": "BA", "lighting_primary_space_type": "Religious Building", "lighting_per_area": 1.3, @@ -225,7 +200,6 @@ "annotation": "" }, { - "id": 26, "method": "BA", "lighting_primary_space_type": "Retail", "lighting_per_area": 1.5, @@ -234,7 +208,6 @@ "annotation": "" }, { - "id": 27, "method": "BA", "lighting_primary_space_type": "School/University", "lighting_per_area": 1.2, @@ -243,7 +216,6 @@ "annotation": "" }, { - "id": 28, "method": "BA", "lighting_primary_space_type": "Sports Arena", "lighting_per_area": 1.1, @@ -252,7 +224,6 @@ "annotation": "" }, { - "id": 29, "method": "BA", "lighting_primary_space_type": "Town Hall", "lighting_per_area": 1.1, @@ -261,7 +232,6 @@ "annotation": "" }, { - "id": 30, "method": "BA", "lighting_primary_space_type": "Transportation", "lighting_per_area": 1, @@ -270,7 +240,6 @@ "annotation": "" }, { - "id": 31, "method": "BA", "lighting_primary_space_type": "Warehouse", "lighting_per_area": 0.8, @@ -279,7 +248,6 @@ "annotation": "" }, { - "id": 32, "method": "BA", "lighting_primary_space_type": "Workshop", "lighting_per_area": 1.4, @@ -288,7 +256,6 @@ "annotation": "" }, { - "id": 33, "method": "CS", "lighting_primary_space_type": "Office-Enclosed", "lighting_per_area": 1.1, @@ -297,7 +264,6 @@ "annotation": "" }, { - "id": 34, "method": "CS", "lighting_primary_space_type": "Office-Open Plan", "lighting_per_area": 1.1, @@ -306,7 +272,6 @@ "annotation": "" }, { - "id": 35, "method": "CS", "lighting_primary_space_type": "Conference/Meeting/Multipurpose", "lighting_per_area": 1.3, @@ -315,7 +280,6 @@ "annotation": "" }, { - "id": 36, "method": "CS", "lighting_primary_space_type": "Classroom/Lecture/Training", "lighting_per_area": 1.4, @@ -324,7 +288,6 @@ "annotation": "" }, { - "id": 37, "method": "CS", "lighting_primary_space_type": "Classroom/Lecture/Training", "lighting_per_area": 1.3, @@ -333,7 +296,6 @@ "annotation": "" }, { - "id": 38, "method": "CS", "lighting_primary_space_type": "Lobby", "lighting_per_area": 1.3, @@ -342,7 +304,6 @@ "annotation": "" }, { - "id": 39, "method": "CS", "lighting_primary_space_type": "Lobby", "lighting_per_area": 1.1, @@ -351,7 +312,6 @@ "annotation": "" }, { - "id": 40, "method": "CS", "lighting_primary_space_type": "Lobby", "lighting_per_area": 3.3, @@ -360,7 +320,6 @@ "annotation": "" }, { - "id": 41, "method": "CS", "lighting_primary_space_type": "Lobby", "lighting_per_area": 1.1, @@ -369,7 +328,6 @@ "annotation": "" }, { - "id": 42, "method": "CS", "lighting_primary_space_type": "Audience/Seating Area", "lighting_per_area": 0.9, @@ -378,7 +336,6 @@ "annotation": "" }, { - "id": 43, "method": "CS", "lighting_primary_space_type": "Audience/Seating Area", "lighting_per_area": 0.4, @@ -387,7 +344,6 @@ "annotation": "" }, { - "id": 44, "method": "CS", "lighting_primary_space_type": "Audience/Seating Area", "lighting_per_area": 0.3, @@ -396,7 +352,6 @@ "annotation": "" }, { - "id": 45, "method": "CS", "lighting_primary_space_type": "Audience/Seating Area", "lighting_per_area": 0.7, @@ -405,7 +360,6 @@ "annotation": "" }, { - "id": 46, "method": "CS", "lighting_primary_space_type": "Audience/Seating Area", "lighting_per_area": 0.7, @@ -414,7 +368,6 @@ "annotation": "" }, { - "id": 47, "method": "CS", "lighting_primary_space_type": "Audience/Seating Area", "lighting_per_area": 1.7, @@ -423,7 +376,6 @@ "annotation": "" }, { - "id": 48, "method": "CS", "lighting_primary_space_type": "Audience/Seating Area", "lighting_per_area": 0.4, @@ -432,7 +384,6 @@ "annotation": "" }, { - "id": 49, "method": "CS", "lighting_primary_space_type": "Audience/Seating Area", "lighting_per_area": 2.6, @@ -441,7 +392,6 @@ "annotation": "" }, { - "id": 50, "method": "CS", "lighting_primary_space_type": "Audience/Seating Area", "lighting_per_area": 1.2, @@ -450,7 +400,6 @@ "annotation": "" }, { - "id": 51, "method": "CS", "lighting_primary_space_type": "Audience/Seating Area", "lighting_per_area": 0.5, @@ -459,25 +408,22 @@ "annotation": "" }, { - "id": 52, "method": "CS", - "lighting_primary_space_type": "Atrium\u00ef\u00bf\u00bdFirst Three Floors", + "lighting_primary_space_type": "Atrium: First Three Floors", "lighting_per_area": 0.6, "lighting_secondary_space_type": "General", "lighting_per_area_unit": "W/ft2", "annotation": "" }, { - "id": 53, "method": "CS", - "lighting_primary_space_type": "Atrium\u00ef\u00bf\u00bdEach Additional Floor", + "lighting_primary_space_type": "Atrium: Each Additional Floor", "lighting_per_area": 0.2, "lighting_secondary_space_type": "General", "lighting_per_area_unit": "W/ft2", "annotation": "" }, { - "id": 54, "method": "CS", "lighting_primary_space_type": "Lounge/Recreation", "lighting_per_area": 1.2, @@ -486,7 +432,6 @@ "annotation": "" }, { - "id": 55, "method": "CS", "lighting_primary_space_type": "Lounge/Recreation", "lighting_per_area": 0.8, @@ -495,7 +440,6 @@ "annotation": "" }, { - "id": 56, "method": "CS", "lighting_primary_space_type": "Dining Area", "lighting_per_area": 0.9, @@ -504,7 +448,6 @@ "annotation": "" }, { - "id": 57, "method": "CS", "lighting_primary_space_type": "Dining Area", "lighting_per_area": 1.3, @@ -513,7 +456,6 @@ "annotation": "" }, { - "id": 58, "method": "CS", "lighting_primary_space_type": "Dining Area", "lighting_per_area": 1.3, @@ -522,7 +464,6 @@ "annotation": "" }, { - "id": 59, "method": "CS", "lighting_primary_space_type": "Dining Area", "lighting_per_area": 1.2, @@ -531,7 +472,6 @@ "annotation": "" }, { - "id": 60, "method": "CS", "lighting_primary_space_type": "Dining Area", "lighting_per_area": 1.4, @@ -540,7 +480,6 @@ "annotation": "" }, { - "id": 61, "method": "CS", "lighting_primary_space_type": "Dining Area", "lighting_per_area": 2.1, @@ -549,7 +488,6 @@ "annotation": "" }, { - "id": 62, "method": "CS", "lighting_primary_space_type": "Food Preparation", "lighting_per_area": 1.2, @@ -558,7 +496,6 @@ "annotation": "" }, { - "id": 63, "method": "CS", "lighting_primary_space_type": "Laboratory", "lighting_per_area": 1.4, @@ -567,7 +504,6 @@ "annotation": "" }, { - "id": 64, "method": "CS", "lighting_primary_space_type": "Restrooms", "lighting_per_area": 0.9, @@ -576,7 +512,6 @@ "annotation": "" }, { - "id": 65, "method": "CS", "lighting_primary_space_type": "Dressing/Locker/Fitting Room", "lighting_per_area": 0.6, @@ -585,7 +520,6 @@ "annotation": "" }, { - "id": 66, "method": "CS", "lighting_primary_space_type": "Corridor/Transition", "lighting_per_area": 0.5, @@ -594,7 +528,6 @@ "annotation": "" }, { - "id": 67, "method": "CS", "lighting_primary_space_type": "Corridor/Transition", "lighting_per_area": 1, @@ -603,7 +536,6 @@ "annotation": "" }, { - "id": 68, "method": "CS", "lighting_primary_space_type": "Corridor/Transition", "lighting_per_area": 0.5, @@ -612,16 +544,14 @@ "annotation": "" }, { - "id": 69, "method": "CS", - "lighting_primary_space_type": "Stairs\u00ef\u00bf\u00bdActive", + "lighting_primary_space_type": "Stairs: Active", "lighting_per_area": 0.6, "lighting_secondary_space_type": "General", "lighting_per_area_unit": "W/ft2", "annotation": "" }, { - "id": 70, "method": "CS", "lighting_primary_space_type": "Active Storage", "lighting_per_area": 0.8, @@ -630,7 +560,6 @@ "annotation": "" }, { - "id": 71, "method": "CS", "lighting_primary_space_type": "Active Storage", "lighting_per_area": 0.9, @@ -639,7 +568,6 @@ "annotation": "" }, { - "id": 72, "method": "CS", "lighting_primary_space_type": "Inactive Storage", "lighting_per_area": 0.3, @@ -648,7 +576,6 @@ "annotation": "" }, { - "id": 73, "method": "CS", "lighting_primary_space_type": "Inactive Storage", "lighting_per_area": 0.8, @@ -657,7 +584,6 @@ "annotation": "" }, { - "id": 74, "method": "CS", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_per_area": 1.5, @@ -666,7 +592,6 @@ "annotation": "" }, { - "id": 75, "method": "CS", "lighting_primary_space_type": "Workshop", "lighting_per_area": 1.9, @@ -675,7 +600,6 @@ "annotation": "" }, { - "id": 76, "method": "SS", "lighting_primary_space_type": "Gymnasium/Exercise Center", "lighting_per_area": 1.4, @@ -684,7 +608,6 @@ "annotation": "" }, { - "id": 77, "method": "SS", "lighting_primary_space_type": "Gymnasium/Exercise Center", "lighting_per_area": 0.9, @@ -693,7 +616,6 @@ "annotation": "" }, { - "id": 78, "method": "SS", "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", "lighting_per_area": 1.9, @@ -702,7 +624,6 @@ "annotation": "" }, { - "id": 79, "method": "SS", "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", "lighting_per_area": 0.9, @@ -711,7 +632,6 @@ "annotation": "" }, { - "id": 80, "method": "SS", "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", "lighting_per_area": 1.3, @@ -720,7 +640,6 @@ "annotation": "" }, { - "id": 81, "method": "SS", "lighting_primary_space_type": "Fire Stations", "lighting_per_area": 0.8, @@ -729,7 +648,6 @@ "annotation": "" }, { - "id": 82, "method": "SS", "lighting_primary_space_type": "Fire Stations", "lighting_per_area": 0.3, @@ -738,25 +656,22 @@ "annotation": "" }, { - "id": 83, "method": "SS", - "lighting_primary_space_type": "Post Office\u00ef\u00bf\u00bdSorting Area", + "lighting_primary_space_type": "Post Office: Sorting Area", "lighting_per_area": 1.2, "lighting_secondary_space_type": "General", "lighting_per_area_unit": "W/ft2", "annotation": "" }, { - "id": 84, "method": "SS", - "lighting_primary_space_type": "Convention Center\u00ef\u00bf\u00bdExhibit Space", + "lighting_primary_space_type": "Convention Center: Exhibit Space", "lighting_per_area": 1.3, "lighting_secondary_space_type": "General", "lighting_per_area_unit": "W/ft2", "annotation": "" }, { - "id": 85, "method": "SS", "lighting_primary_space_type": "Library", "lighting_per_area": 1.1, @@ -765,7 +680,6 @@ "annotation": "" }, { - "id": 86, "method": "SS", "lighting_primary_space_type": "Library", "lighting_per_area": 1.7, @@ -774,7 +688,6 @@ "annotation": "" }, { - "id": 87, "method": "SS", "lighting_primary_space_type": "Library", "lighting_per_area": 1.2, @@ -783,7 +696,6 @@ "annotation": "" }, { - "id": 88, "method": "SS", "lighting_primary_space_type": "Hospital", "lighting_per_area": 2.7, @@ -792,7 +704,6 @@ "annotation": "" }, { - "id": 89, "method": "SS", "lighting_primary_space_type": "Hospital", "lighting_per_area": 0.8, @@ -801,7 +712,6 @@ "annotation": "" }, { - "id": 90, "method": "SS", "lighting_primary_space_type": "Hospital", "lighting_per_area": 1, @@ -810,7 +720,6 @@ "annotation": "" }, { - "id": 91, "method": "SS", "lighting_primary_space_type": "Hospital", "lighting_per_area": 1.5, @@ -819,7 +728,6 @@ "annotation": "" }, { - "id": 92, "method": "SS", "lighting_primary_space_type": "Hospital", "lighting_per_area": 1.2, @@ -828,7 +736,6 @@ "annotation": "" }, { - "id": 93, "method": "SS", "lighting_primary_space_type": "Hospital", "lighting_per_area": 0.7, @@ -837,7 +744,6 @@ "annotation": "" }, { - "id": 94, "method": "SS", "lighting_primary_space_type": "Hospital", "lighting_per_area": 2.2, @@ -846,7 +752,6 @@ "annotation": "" }, { - "id": 95, "method": "SS", "lighting_primary_space_type": "Hospital", "lighting_per_area": 0.6, @@ -855,7 +760,6 @@ "annotation": "" }, { - "id": 96, "method": "SS", "lighting_primary_space_type": "Hospital", "lighting_per_area": 1.4, @@ -864,7 +768,6 @@ "annotation": "" }, { - "id": 97, "method": "SS", "lighting_primary_space_type": "Hospital", "lighting_per_area": 0.9, @@ -873,7 +776,6 @@ "annotation": "" }, { - "id": 98, "method": "SS", "lighting_primary_space_type": "Hospital", "lighting_per_area": 0.4, @@ -882,25 +784,22 @@ "annotation": "" }, { - "id": 99, "method": "SS", "lighting_primary_space_type": "Hospital", "lighting_per_area": 0.6, - "lighting_secondary_space_type": "Laundry\u00ef\u00bf\u00bdWashing", + "lighting_secondary_space_type": "Laundry: Washing", "lighting_per_area_unit": "W/ft2", "annotation": "" }, { - "id": 100, "method": "SS", - "lighting_primary_space_type": "Automotive\u00ef\u00bf\u00bdService/Repair", + "lighting_primary_space_type": "Automotive: Service/Repair", "lighting_per_area": 0.7, "lighting_secondary_space_type": "General", "lighting_per_area_unit": "W/ft2", "annotation": "" }, { - "id": 101, "method": "SS", "lighting_primary_space_type": "Manufacturing", "lighting_per_area": 1.2, @@ -909,7 +808,6 @@ "annotation": "" }, { - "id": 102, "method": "SS", "lighting_primary_space_type": "Manufacturing", "lighting_per_area": 1.7, @@ -918,7 +816,6 @@ "annotation": "" }, { - "id": 103, "method": "SS", "lighting_primary_space_type": "Manufacturing", "lighting_per_area": 2.1, @@ -927,7 +824,6 @@ "annotation": "" }, { - "id": 104, "method": "SS", "lighting_primary_space_type": "Manufacturing", "lighting_per_area": 1.2, @@ -936,7 +832,6 @@ "annotation": "" }, { - "id": 105, "method": "SS", "lighting_primary_space_type": "Manufacturing", "lighting_per_area": 0.5, @@ -945,7 +840,6 @@ "annotation": "" }, { - "id": 106, "method": "SS", "lighting_primary_space_type": "Hotel/Motel Guest Rooms", "lighting_per_area": 1.1, @@ -954,16 +848,14 @@ "annotation": "" }, { - "id": 107, "method": "SS", - "lighting_primary_space_type": "Dormitory\u00ef\u00bf\u00bdLiving Quarters", + "lighting_primary_space_type": "Dormitory: Living Quarters", "lighting_per_area": 1.1, "lighting_secondary_space_type": "General", "lighting_per_area_unit": "W/ft2", "annotation": "" }, { - "id": 108, "method": "SS", "lighting_primary_space_type": "Museum", "lighting_per_area": 1, @@ -972,7 +864,6 @@ "annotation": "" }, { - "id": 109, "method": "SS", "lighting_primary_space_type": "Museum", "lighting_per_area": 1.7, @@ -981,16 +872,14 @@ "annotation": "" }, { - "id": 110, "method": "SS", - "lighting_primary_space_type": "Bank/Office\u00ef\u00bf\u00bdBanking Activity Area", + "lighting_primary_space_type": "Bank/Office: Banking Activity Area", "lighting_per_area": 1.5, "lighting_secondary_space_type": "General", "lighting_per_area_unit": "W/ft2", "annotation": "" }, { - "id": 111, "method": "SS", "lighting_primary_space_type": "Religious Buildings", "lighting_per_area": 2.4, @@ -999,7 +888,6 @@ "annotation": "" }, { - "id": 112, "method": "SS", "lighting_primary_space_type": "Religious Buildings", "lighting_per_area": 0.9, @@ -1008,7 +896,6 @@ "annotation": "" }, { - "id": 113, "method": "SS", "lighting_primary_space_type": "Retail", "lighting_per_area": 1.7, @@ -1017,7 +904,6 @@ "annotation": "" }, { - "id": 114, "method": "SS", "lighting_primary_space_type": "Retail", "lighting_per_area": 1.7, @@ -1026,7 +912,6 @@ "annotation": "" }, { - "id": 115, "method": "SS", "lighting_primary_space_type": "Sports Arena", "lighting_per_area": 2.7, @@ -1035,7 +920,6 @@ "annotation": "" }, { - "id": 116, "method": "SS", "lighting_primary_space_type": "Sports Arena", "lighting_per_area": 2.3, @@ -1044,7 +928,6 @@ "annotation": "" }, { - "id": 117, "method": "SS", "lighting_primary_space_type": "Sports Arena", "lighting_per_area": 1.4, @@ -1053,7 +936,6 @@ "annotation": "" }, { - "id": 118, "method": "SS", "lighting_primary_space_type": "Warehouse", "lighting_per_area": 1.4, @@ -1062,7 +944,6 @@ "annotation": "" }, { - "id": 119, "method": "SS", "lighting_primary_space_type": "Warehouse", "lighting_per_area": 0.9, @@ -1071,43 +952,38 @@ "annotation": "" }, { - "id": 120, "method": "SS", - "lighting_primary_space_type": "Parking Garage\u00ef\u00bf\u00bdGarage Area", + "lighting_primary_space_type": "Parking Garage: Garage Area", "lighting_per_area": 0.2, "lighting_secondary_space_type": "General", "lighting_per_area_unit": "W/ft2", "annotation": "" }, { - "id": 121, "method": "SS", "lighting_primary_space_type": "Transportation", "lighting_per_area": 0.6, - "lighting_secondary_space_type": "Airport\u00ef\u00bf\u00bdConcourse", + "lighting_secondary_space_type": "Airport: Concourse", "lighting_per_area_unit": "W/ft2", "annotation": "" }, { - "id": 122, "method": "SS", "lighting_primary_space_type": "Transportation", "lighting_per_area": 1, - "lighting_secondary_space_type": "Air/Train/Bus\u00ef\u00bf\u00bdBaggage Area", + "lighting_secondary_space_type": "Air/Train/Bus: Baggage Area", "lighting_per_area_unit": "W/ft2", "annotation": "" }, { - "id": 123, "method": "SS", "lighting_primary_space_type": "Transportation", "lighting_per_area": 1.5, - "lighting_secondary_space_type": "Terminal\u00ef\u00bf\u00bdTicket Counter", + "lighting_secondary_space_type": "Terminal: Ticket Counter", "lighting_per_area_unit": "W/ft2", "annotation": "" }, { - "id": 124, "method": "SS", "lighting_primary_space_type": "Retail", "lighting_per_area": 1.6, @@ -1116,7 +992,6 @@ "annotation": "" }, { - "id": 125, "method": "SS", "lighting_primary_space_type": "Retail", "lighting_per_area": 3.9, diff --git a/data/openstudio_standards_data/initial_data/light_def_90_1_2019.json b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2019.json similarity index 91% rename from data/openstudio_standards_data/initial_data/light_def_90_1_2019.json rename to data/openstudio_standards_data/database_files/level_3_lighting_90_1_2019.json index 343a0a7a43..92cd21efe0 100644 --- a/data/openstudio_standards_data/initial_data/light_def_90_1_2019.json +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2019.json @@ -1,6 +1,5 @@ [ { - "id": 1, "method": "BA", "lighting_primary_space_type": "Automotive facility", "lighting_per_area": 0.75, @@ -9,7 +8,6 @@ "annotation": "" }, { - "id": 2, "method": "BA", "lighting_primary_space_type": "Convention center", "lighting_per_area": 0.64, @@ -18,7 +16,6 @@ "annotation": "" }, { - "id": 3, "method": "BA", "lighting_primary_space_type": "Courthouse", "lighting_per_area": 0.79, @@ -27,7 +24,6 @@ "annotation": "" }, { - "id": 4, "method": "BA", "lighting_primary_space_type": "Dining: Bar lounge/leisure", "lighting_per_area": 0.8, @@ -36,7 +32,6 @@ "annotation": "" }, { - "id": 5, "method": "BA", "lighting_primary_space_type": "Dining: Cafeteria/fast food", "lighting_per_area": 0.76, @@ -45,7 +40,6 @@ "annotation": "" }, { - "id": 6, "method": "BA", "lighting_primary_space_type": "Dining: Family", "lighting_per_area": 0.71, @@ -54,7 +48,6 @@ "annotation": "" }, { - "id": 7, "method": "BA", "lighting_primary_space_type": "Dormitory", "lighting_per_area": 0.53, @@ -63,7 +56,6 @@ "annotation": "" }, { - "id": 8, "method": "BA", "lighting_primary_space_type": "Exercise center", "lighting_per_area": 0.72, @@ -72,7 +64,6 @@ "annotation": "" }, { - "id": 9, "method": "BA", "lighting_primary_space_type": "Fire station", "lighting_per_area": 0.56, @@ -81,7 +72,6 @@ "annotation": "" }, { - "id": 10, "method": "BA", "lighting_primary_space_type": "Gymnasium", "lighting_per_area": 0.76, @@ -90,7 +80,6 @@ "annotation": "" }, { - "id": 11, "method": "BA", "lighting_primary_space_type": "Health-care clinic", "lighting_per_area": 0.81, @@ -99,7 +88,6 @@ "annotation": "" }, { - "id": 12, "method": "BA", "lighting_primary_space_type": "Hospital", "lighting_per_area": 0.96, @@ -108,7 +96,6 @@ "annotation": "" }, { - "id": 13, "method": "BA", "lighting_primary_space_type": "Hotel/motel", "lighting_per_area": 0.56, @@ -117,7 +104,6 @@ "annotation": "" }, { - "id": 14, "method": "BA", "lighting_primary_space_type": "Library", "lighting_per_area": 0.83, @@ -126,7 +112,6 @@ "annotation": "" }, { - "id": 15, "method": "BA", "lighting_primary_space_type": "Manufacturing facility", "lighting_per_area": 0.82, @@ -135,7 +120,6 @@ "annotation": "" }, { - "id": 16, "method": "BA", "lighting_primary_space_type": "Motion picture theater", "lighting_per_area": 0.44, @@ -144,7 +128,6 @@ "annotation": "" }, { - "id": 17, "method": "BA", "lighting_primary_space_type": "Multifamily", "lighting_per_area": 0.45, @@ -153,7 +136,6 @@ "annotation": "" }, { - "id": 18, "method": "BA", "lighting_primary_space_type": "Museum", "lighting_per_area": 0.55, @@ -162,7 +144,6 @@ "annotation": "" }, { - "id": 19, "method": "BA", "lighting_primary_space_type": "Office", "lighting_per_area": 0.64, @@ -171,7 +152,6 @@ "annotation": "" }, { - "id": 20, "method": "BA", "lighting_primary_space_type": "Parking garage", "lighting_per_area": 0.18, @@ -180,7 +160,6 @@ "annotation": "" }, { - "id": 21, "method": "BA", "lighting_primary_space_type": "Penitentiary", "lighting_per_area": 0.69, @@ -189,7 +168,6 @@ "annotation": "" }, { - "id": 22, "method": "BA", "lighting_primary_space_type": "Performing arts theater", "lighting_per_area": 0.84, @@ -198,7 +176,6 @@ "annotation": "" }, { - "id": 23, "method": "BA", "lighting_primary_space_type": "Police station", "lighting_per_area": 0.66, @@ -207,7 +184,6 @@ "annotation": "" }, { - "id": 24, "method": "BA", "lighting_primary_space_type": "Post office", "lighting_per_area": 0.65, @@ -216,7 +192,6 @@ "annotation": "" }, { - "id": 25, "method": "BA", "lighting_primary_space_type": "Religious facility", "lighting_per_area": 0.67, @@ -225,7 +200,6 @@ "annotation": "" }, { - "id": 26, "method": "BA", "lighting_primary_space_type": "Retail", "lighting_per_area": 0.84, @@ -234,7 +208,6 @@ "annotation": "" }, { - "id": 27, "method": "BA", "lighting_primary_space_type": "School/university", "lighting_per_area": 0.72, @@ -243,7 +216,6 @@ "annotation": "" }, { - "id": 28, "method": "BA", "lighting_primary_space_type": "Sports arena", "lighting_per_area": 0.76, @@ -252,7 +224,6 @@ "annotation": "" }, { - "id": 29, "method": "BA", "lighting_primary_space_type": "Town hall", "lighting_per_area": 0.69, @@ -261,7 +232,6 @@ "annotation": "" }, { - "id": 30, "method": "BA", "lighting_primary_space_type": "Transportation", "lighting_per_area": 0.5, @@ -270,7 +240,6 @@ "annotation": "" }, { - "id": 31, "method": "BA", "lighting_primary_space_type": "Warehouse", "lighting_per_area": 0.45, @@ -279,7 +248,6 @@ "annotation": "" }, { - "id": 32, "method": "BA", "lighting_primary_space_type": "Workshop", "lighting_per_area": 0.91, @@ -288,7 +256,6 @@ "annotation": "" }, { - "id": 33, "method": "CS", "lighting_primary_space_type": "Atrium", "lighting_per_area": 0.39, @@ -297,7 +264,6 @@ "annotation": "" }, { - "id": 34, "method": "CS", "lighting_primary_space_type": "Atrium", "lighting_per_area": 0.48, @@ -306,7 +272,6 @@ "annotation": "" }, { - "id": 35, "method": "CS", "lighting_primary_space_type": "Atrium", "lighting_per_area": 0.6, @@ -315,7 +280,6 @@ "annotation": "" }, { - "id": 36, "method": "CS", "lighting_primary_space_type": "Audience Seating Area", "lighting_per_area": 0.61, @@ -324,7 +288,6 @@ "annotation": "" }, { - "id": 37, "method": "CS", "lighting_primary_space_type": "Audience Seating Area", "lighting_per_area": 0.23, @@ -333,7 +296,6 @@ "annotation": "" }, { - "id": 38, "method": "CS", "lighting_primary_space_type": "Audience Seating Area", "lighting_per_area": 0.27, @@ -342,7 +304,6 @@ "annotation": "" }, { - "id": 39, "method": "CS", "lighting_primary_space_type": "Audience Seating Area", "lighting_per_area": 0.67, @@ -351,7 +312,6 @@ "annotation": "" }, { - "id": 40, "method": "CS", "lighting_primary_space_type": "Audience Seating Area", "lighting_per_area": 1.16, @@ -360,7 +320,6 @@ "annotation": "" }, { - "id": 41, "method": "CS", "lighting_primary_space_type": "Audience Seating Area", "lighting_per_area": 0.72, @@ -369,7 +328,6 @@ "annotation": "" }, { - "id": 42, "method": "CS", "lighting_primary_space_type": "Audience Seating Area", "lighting_per_area": 0.33, @@ -378,7 +336,6 @@ "annotation": "" }, { - "id": 43, "method": "CS", "lighting_primary_space_type": "Audience Seating Area", "lighting_per_area": 0.23, @@ -387,7 +344,6 @@ "annotation": "" }, { - "id": 44, "method": "CS", "lighting_primary_space_type": "Banking Activity Area", "lighting_per_area": 0.61, @@ -396,7 +352,6 @@ "annotation": "" }, { - "id": 45, "method": "CS", "lighting_primary_space_type": "Breakroom", "lighting_per_area": 0.59, @@ -405,7 +360,6 @@ "annotation": "(See Lounge/Breakroom)" }, { - "id": 46, "method": "CS", "lighting_primary_space_type": "Classroom/Lecture Hall/Training Room", "lighting_per_area": 0.89, @@ -414,7 +368,6 @@ "annotation": "" }, { - "id": 47, "method": "CS", "lighting_primary_space_type": "Classroom/Lecture Hall/Training Room", "lighting_per_area": 0.71, @@ -423,7 +376,6 @@ "annotation": "" }, { - "id": 48, "method": "CS", "lighting_primary_space_type": "Conference/Meeting/Multipurpose Room", "lighting_per_area": 0.97, @@ -432,7 +384,6 @@ "annotation": "" }, { - "id": 49, "method": "CS", "lighting_primary_space_type": "Confinement Cells", "lighting_per_area": 0.7, @@ -441,7 +392,6 @@ "annotation": "" }, { - "id": 50, "method": "CS", "lighting_primary_space_type": "Copy/Print Room", "lighting_per_area": 0.31, @@ -450,7 +400,6 @@ "annotation": "" }, { - "id": 51, "method": "CS", "lighting_primary_space_type": "Corridor", "lighting_per_area": 0.71, @@ -459,7 +408,6 @@ "annotation": "" }, { - "id": 52, "method": "CS", "lighting_primary_space_type": "Corridor", "lighting_per_area": 0.71, @@ -468,7 +416,6 @@ "annotation": "" }, { - "id": 53, "method": "CS", "lighting_primary_space_type": "Corridor", "lighting_per_area": 0.41, @@ -477,7 +424,6 @@ "annotation": "" }, { - "id": 54, "method": "CS", "lighting_primary_space_type": "Courtroom", "lighting_per_area": 1.2, @@ -486,7 +432,6 @@ "annotation": "" }, { - "id": 55, "method": "CS", "lighting_primary_space_type": "Computer Room", "lighting_per_area": 0.94, @@ -495,7 +440,6 @@ "annotation": "" }, { - "id": 56, "method": "CS", "lighting_primary_space_type": "Dining Area", "lighting_per_area": 0.42, @@ -504,7 +448,6 @@ "annotation": "" }, { - "id": 57, "method": "CS", "lighting_primary_space_type": "Dining Area", "lighting_per_area": 1.27, @@ -513,7 +456,6 @@ "annotation": "" }, { - "id": 58, "method": "CS", "lighting_primary_space_type": "Dining Area", "lighting_per_area": 0.86, @@ -522,7 +464,6 @@ "annotation": "" }, { - "id": 59, "method": "CS", "lighting_primary_space_type": "Dining Area", "lighting_per_area": 0.4, @@ -531,7 +472,6 @@ "annotation": "" }, { - "id": 60, "method": "CS", "lighting_primary_space_type": "Dining Area", "lighting_per_area": 0.6, @@ -540,7 +480,6 @@ "annotation": "" }, { - "id": 61, "method": "CS", "lighting_primary_space_type": "Dining Area", "lighting_per_area": 0.43, @@ -549,7 +488,6 @@ "annotation": "" }, { - "id": 62, "method": "CS", "lighting_primary_space_type": "Electrical/Mechanical Room", "lighting_per_area": 0.43, @@ -558,7 +496,6 @@ "annotation": "" }, { - "id": 63, "method": "CS", "lighting_primary_space_type": "Emergency Vehicle Garage", "lighting_per_area": 0.52, @@ -567,7 +504,6 @@ "annotation": "" }, { - "id": 64, "method": "CS", "lighting_primary_space_type": "Food Preparation Area", "lighting_per_area": 1.09, @@ -576,7 +512,6 @@ "annotation": "" }, { - "id": 65, "method": "CS", "lighting_primary_space_type": "Guest Room", "lighting_per_area": 0.41, @@ -585,7 +520,6 @@ "annotation": "" }, { - "id": 66, "method": "CS", "lighting_primary_space_type": "Laboratory", "lighting_per_area": 1.11, @@ -594,7 +528,6 @@ "annotation": "" }, { - "id": 67, "method": "CS", "lighting_primary_space_type": "Laboratory", "lighting_per_area": 1.33, @@ -603,7 +536,6 @@ "annotation": "" }, { - "id": 68, "method": "CS", "lighting_primary_space_type": "Laundry/Washing Area", "lighting_per_area": 0.53, @@ -612,7 +544,6 @@ "annotation": "" }, { - "id": 69, "method": "CS", "lighting_primary_space_type": "Loading Dock, Interior", "lighting_per_area": 0.88, @@ -621,7 +552,6 @@ "annotation": "" }, { - "id": 70, "method": "CS", "lighting_primary_space_type": "Lobby", "lighting_per_area": 1.69, @@ -630,7 +560,6 @@ "annotation": "" }, { - "id": 71, "method": "CS", "lighting_primary_space_type": "Lobby", "lighting_per_area": 0.65, @@ -639,7 +568,6 @@ "annotation": "" }, { - "id": 72, "method": "CS", "lighting_primary_space_type": "Lobby", "lighting_per_area": 0.51, @@ -648,7 +576,6 @@ "annotation": "" }, { - "id": 73, "method": "CS", "lighting_primary_space_type": "Lobby", "lighting_per_area": 0.23, @@ -657,7 +584,6 @@ "annotation": "" }, { - "id": 74, "method": "CS", "lighting_primary_space_type": "Lobby", "lighting_per_area": 1.25, @@ -666,7 +592,6 @@ "annotation": "" }, { - "id": 75, "method": "CS", "lighting_primary_space_type": "Lobby", "lighting_per_area": 0.84, @@ -675,7 +600,6 @@ "annotation": "" }, { - "id": 76, "method": "CS", "lighting_primary_space_type": "Locker Room", "lighting_per_area": 0.52, @@ -684,7 +608,6 @@ "annotation": "" }, { - "id": 77, "method": "CS", "lighting_primary_space_type": "Lounge/Breakroom", "lighting_per_area": 0.42, @@ -693,7 +616,6 @@ "annotation": "" }, { - "id": 78, "method": "CS", "lighting_primary_space_type": "Lounge/Breakroom", "lighting_per_area": 0.59, @@ -702,7 +624,6 @@ "annotation": "" }, { - "id": 79, "method": "CS", "lighting_primary_space_type": "Office", "lighting_per_area": 0.74, @@ -711,7 +632,6 @@ "annotation": "" }, { - "id": 80, "method": "CS", "lighting_primary_space_type": "Office", "lighting_per_area": 0.66, @@ -720,7 +640,6 @@ "annotation": "" }, { - "id": 81, "method": "CS", "lighting_primary_space_type": "Office", "lighting_per_area": 0.61, @@ -729,7 +648,6 @@ "annotation": "" }, { - "id": 82, "method": "CS", "lighting_primary_space_type": "Parking Area, Interior", "lighting_per_area": 0.15, @@ -738,7 +656,6 @@ "annotation": "" }, { - "id": 83, "method": "CS", "lighting_primary_space_type": "Pharmacy Area", "lighting_per_area": 1.66, @@ -747,7 +664,6 @@ "annotation": "" }, { - "id": 84, "method": "CS", "lighting_primary_space_type": "Restroom", "lighting_per_area": 1.26, @@ -756,7 +672,6 @@ "annotation": "" }, { - "id": 85, "method": "CS", "lighting_primary_space_type": "Restroom", "lighting_per_area": 0.63, @@ -765,7 +680,6 @@ "annotation": "" }, { - "id": 86, "method": "CS", "lighting_primary_space_type": "Sales Area", "lighting_per_area": 1.05, @@ -774,7 +688,6 @@ "annotation": "" }, { - "id": 87, "method": "CS", "lighting_primary_space_type": "Seating Area, General", "lighting_per_area": 0.23, @@ -783,7 +696,6 @@ "annotation": "" }, { - "id": 88, "method": "CS", "lighting_primary_space_type": "Stairway", "lighting_per_area": 0.49, @@ -792,7 +704,6 @@ "annotation": "The space containing the stairway shall determine the LPD and control requirements for the stairway." }, { - "id": 89, "method": "CS", "lighting_primary_space_type": "Stairwell", "lighting_per_area": 0.49, @@ -801,7 +712,6 @@ "annotation": "" }, { - "id": 90, "method": "CS", "lighting_primary_space_type": "Storage Room", "lighting_per_area": 0.51, @@ -810,7 +720,6 @@ "annotation": "" }, { - "id": 91, "method": "CS", "lighting_primary_space_type": "Storage Room", "lighting_per_area": 0.38, @@ -819,7 +728,6 @@ "annotation": "" }, { - "id": 92, "method": "CS", "lighting_primary_space_type": "Vehicular Maintenance Area", "lighting_per_area": 0.6, @@ -828,7 +736,6 @@ "annotation": "" }, { - "id": 93, "method": "CS", "lighting_primary_space_type": "Workshop", "lighting_per_area": 1.26, @@ -837,7 +744,6 @@ "annotation": "" }, { - "id": 94, "method": "SS", "lighting_primary_space_type": "Facility for the Visually Impaired", "lighting_per_area": 0.7, @@ -846,7 +752,6 @@ "annotation": "" }, { - "id": 95, "method": "SS", "lighting_primary_space_type": "Facility for the Visually Impaired", "lighting_per_area": 1.77, @@ -855,43 +760,38 @@ "annotation": "" }, { - "id": 96, "method": "SS", "lighting_primary_space_type": "Automotive", "lighting_per_area": 0.6, "lighting_secondary_space_type": "General", "lighting_per_area_unit": "W/ft2", - "annotation": "(See \u201cVehicular Maintenance Area\u201d)" + "annotation": "(See 'Vehicular Maintenance Area')" }, { - "id": 97, "method": "SS", - "lighting_primary_space_type": "Convention Center\u2014Exhibit Space", + "lighting_primary_space_type": "Convention Center: Exhibit Space", "lighting_per_area": 0.61, "lighting_secondary_space_type": "General", "lighting_per_area_unit": "W/ft2", "annotation": "" }, { - "id": 98, "method": "SS", - "lighting_primary_space_type": "Dormitory\u2014Living Quarters", + "lighting_primary_space_type": "Dormitory: Living Quarters", "lighting_per_area": 0.5, "lighting_secondary_space_type": "General", "lighting_per_area_unit": "W/ft2", "annotation": "" }, { - "id": 99, "method": "SS", - "lighting_primary_space_type": "Fire Station\u2014Sleeping Quarters", + "lighting_primary_space_type": "Fire Station: Sleeping Quarters", "lighting_per_area": 0.23, "lighting_secondary_space_type": "General", "lighting_per_area_unit": "W/ft2", "annotation": "" }, { - "id": 100, "method": "SS", "lighting_primary_space_type": "Gymnasium/Fitness Center", "lighting_per_area": 0.9, @@ -900,7 +800,6 @@ "annotation": "" }, { - "id": 101, "method": "SS", "lighting_primary_space_type": "Gymnasium/Fitness Center", "lighting_per_area": 0.85, @@ -909,7 +808,6 @@ "annotation": "" }, { - "id": 102, "method": "SS", "lighting_primary_space_type": "Healthcare Facility", "lighting_per_area": 1.4, @@ -918,7 +816,6 @@ "annotation": "" }, { - "id": 103, "method": "SS", "lighting_primary_space_type": "Healthcare Facility", "lighting_per_area": 0.94, @@ -927,7 +824,6 @@ "annotation": "" }, { - "id": 104, "method": "SS", "lighting_primary_space_type": "Healthcare Facility", "lighting_per_area": 0.62, @@ -936,7 +832,6 @@ "annotation": "" }, { - "id": 105, "method": "SS", "lighting_primary_space_type": "Healthcare Facility", "lighting_per_area": 0.92, @@ -945,16 +840,14 @@ "annotation": "" }, { - "id": 106, "method": "SS", "lighting_primary_space_type": "Healthcare Facility", "lighting_per_area": 1.17, - "lighting_secondary_space_type": "Nurse\u2019s station", + "lighting_secondary_space_type": "Nurse's station", "lighting_per_area_unit": "W/ft2", "annotation": "" }, { - "id": 107, "method": "SS", "lighting_primary_space_type": "Healthcare Facility", "lighting_per_area": 2.26, @@ -963,7 +856,6 @@ "annotation": "" }, { - "id": 108, "method": "SS", "lighting_primary_space_type": "Healthcare Facility", "lighting_per_area": 0.68, @@ -972,7 +864,6 @@ "annotation": "" }, { - "id": 109, "method": "SS", "lighting_primary_space_type": "Healthcare Facility", "lighting_per_area": 0.91, @@ -981,7 +872,6 @@ "annotation": "" }, { - "id": 110, "method": "SS", "lighting_primary_space_type": "Healthcare Facility", "lighting_per_area": 1.25, @@ -990,7 +880,6 @@ "annotation": "" }, { - "id": 111, "method": "SS", "lighting_primary_space_type": "Library", "lighting_per_area": 0.96, @@ -999,7 +888,6 @@ "annotation": "" }, { - "id": 112, "method": "SS", "lighting_primary_space_type": "Library", "lighting_per_area": 1.18, @@ -1008,7 +896,6 @@ "annotation": "" }, { - "id": 113, "method": "SS", "lighting_primary_space_type": "Manufacturing Facility", "lighting_per_area": 0.8, @@ -1017,7 +904,6 @@ "annotation": "" }, { - "id": 114, "method": "SS", "lighting_primary_space_type": "Manufacturing Facility", "lighting_per_area": 0.76, @@ -1026,7 +912,6 @@ "annotation": "" }, { - "id": 115, "method": "SS", "lighting_primary_space_type": "Manufacturing Facility", "lighting_per_area": 1.42, @@ -1035,7 +920,6 @@ "annotation": "" }, { - "id": 116, "method": "SS", "lighting_primary_space_type": "Manufacturing Facility", "lighting_per_area": 1.24, @@ -1044,7 +928,6 @@ "annotation": "" }, { - "id": 117, "method": "SS", "lighting_primary_space_type": "Manufacturing Facility", "lighting_per_area": 0.86, @@ -1053,7 +936,6 @@ "annotation": "" }, { - "id": 118, "method": "SS", "lighting_primary_space_type": "Museum", "lighting_per_area": 0.31, @@ -1062,7 +944,6 @@ "annotation": "" }, { - "id": 119, "method": "SS", "lighting_primary_space_type": "Museum", "lighting_per_area": 1.1, @@ -1071,25 +952,22 @@ "annotation": "" }, { - "id": 120, "method": "SS", - "lighting_primary_space_type": "Performing Arts Theater\u2014Dressing Room", + "lighting_primary_space_type": "Performing Arts Theater: Dressing Room", "lighting_per_area": 0.41, "lighting_secondary_space_type": "General", "lighting_per_area_unit": "W/ft2", "annotation": "" }, { - "id": 121, "method": "SS", - "lighting_primary_space_type": "Post Office\u2014Sorting Area", + "lighting_primary_space_type": "Post Office: Sorting Area", "lighting_per_area": 0.76, "lighting_secondary_space_type": "General", "lighting_per_area_unit": "W/ft2", "annotation": "" }, { - "id": 122, "method": "SS", "lighting_primary_space_type": "Religious Facility", "lighting_per_area": 0.54, @@ -1098,7 +976,6 @@ "annotation": "" }, { - "id": 123, "method": "SS", "lighting_primary_space_type": "Religious Facility", "lighting_per_area": 0.85, @@ -1107,7 +984,6 @@ "annotation": "" }, { - "id": 124, "method": "SS", "lighting_primary_space_type": "Retail Facilities", "lighting_per_area": 0.51, @@ -1116,7 +992,6 @@ "annotation": "" }, { - "id": 125, "method": "SS", "lighting_primary_space_type": "Retail Facilities", "lighting_per_area": 0.82, @@ -1125,43 +1000,38 @@ "annotation": "" }, { - "id": 126, "method": "SS", - "lighting_primary_space_type": "Sports Arena\u2014Playing Area", + "lighting_primary_space_type": "Sports Arena: Playing Area", "lighting_per_area": 2.94, "lighting_secondary_space_type": "Class I facility", "lighting_per_area_unit": "W/ft2", "annotation": "" }, { - "id": 127, "method": "SS", - "lighting_primary_space_type": "Sports Arena\u2014Playing Area", + "lighting_primary_space_type": "Sports Arena: Playing Area", "lighting_per_area": 2.01, "lighting_secondary_space_type": "Class II facility", "lighting_per_area_unit": "W/ft2", "annotation": "" }, { - "id": 128, "method": "SS", - "lighting_primary_space_type": "Sports Arena\u2014Playing Area", + "lighting_primary_space_type": "Sports Arena: Playing Area", "lighting_per_area": 1.3, "lighting_secondary_space_type": "Class III facility", "lighting_per_area_unit": "W/ft2", "annotation": "" }, { - "id": 129, "method": "SS", - "lighting_primary_space_type": "Sports Arena\u2014Playing Area", + "lighting_primary_space_type": "Sports Arena: Playing Area", "lighting_per_area": 0.86, "lighting_secondary_space_type": "Class IV facility", "lighting_per_area_unit": "W/ft2", "annotation": "" }, { - "id": 130, "method": "SS", "lighting_primary_space_type": "Transportation Facility", "lighting_per_area": 0.39, @@ -1170,7 +1040,6 @@ "annotation": "" }, { - "id": 131, "method": "SS", "lighting_primary_space_type": "Transportation Facility", "lighting_per_area": 0.25, @@ -1179,7 +1048,6 @@ "annotation": "" }, { - "id": 132, "method": "SS", "lighting_primary_space_type": "Transportation Facility", "lighting_per_area": 0.51, @@ -1188,25 +1056,22 @@ "annotation": "" }, { - "id": 133, "method": "SS", - "lighting_primary_space_type": "Warehouse\u2014Storage Area", + "lighting_primary_space_type": "Warehouse: Storage Area", "lighting_per_area": 0.33, "lighting_secondary_space_type": "Medium to bulky, palletized items", "lighting_per_area_unit": "W/ft2", "annotation": "" }, { - "id": 134, "method": "SS", - "lighting_primary_space_type": "Warehouse\u2014Storage Area", + "lighting_primary_space_type": "Warehouse: Storage Area", "lighting_per_area": 0.69, "lighting_secondary_space_type": "Smaller, hand-carried items", "lighting_per_area_unit": "W/ft2", "annotation": "" }, { - "id": 135, "method": "SS", "lighting_primary_space_type": "Retail", "lighting_per_area": 0.45, @@ -1215,7 +1080,6 @@ "annotation": "" }, { - "id": 136, "method": "SS", "lighting_primary_space_type": "Retail", "lighting_per_area": 0.45, @@ -1224,7 +1088,6 @@ "annotation": "" }, { - "id": 137, "method": "SS", "lighting_primary_space_type": "Retail", "lighting_per_area": 1.05, @@ -1233,7 +1096,6 @@ "annotation": "" }, { - "id": 138, "method": "SS", "lighting_primary_space_type": "Retail", "lighting_per_area": 1.88, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2004.csv b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2004.csv index dd3fc692d1..d2db97a84d 100644 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2004.csv +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2004.csv @@ -1,64 +1,64 @@ -ventilation_primary_space_type,ventilation_secondary_space_type,ventilation_per_person,ventilation_per_person_unit,ventilation_per_area,ventilation_per_area_unit,occupancy_per_area,occupancy_per_area_unit,air_class,os -Correctional Facilities,Cell,5,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2, -Correctional Facilities,Day room,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1, -Correctional Facilities,Guard stations,5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1, -Correctional Facilities,Booking/waiting,7.5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,2, -Educational Facilities,Daycare (through age 4),10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2, -Educational Facilities,Classrooms (ages 5-8),10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1, -Educational Facilities,Classrooms (age 9 plus),10,cfm/person,0.12,cfm/ft2,35,ppl/1000 ft2,1, -Educational Facilities,Lecture classroom,7.5,cfm/person,0.06,cfm/ft2,65,ppl/1000 ft2,1, -Educational Facilities,Lecture hall (fixed seats),7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1, -Educational Facilities,Art classroom,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2, -Educational Facilities,Science laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,, -Educational Facilities,Wood/metal shop,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2, -Educational Facilities,Computer lab,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1, -Educational Facilities,Media center,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1, -Educational Facilities,Music/theater/dance,10,cfm/person,0.06,cfm/ft2,35,ppl/1000 ft2,1, -Educational Facilities,Multi-use assembly,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1, -Food and Beverage Service,Restaurant dining rooms,7.5,cfm/person,0.18,cfm/ft2,70,ppl/1000 ft2,2, -Food and Beverage Service,Cafeteria/fast food dining,7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2, -Food and Beverage Service,"Bars, cocktail lounges",7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2, -General,Conference/meeting,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1, -General,Corridors,,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,1, -General,Storage rooms,,cfm/person,0.12,cfm/ft2,,ppl/1000 ft2,1, -"Hotels, Motels, Resorts, Dormitories",Bedroom/living Room,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1, -"Hotels, Motels, Resorts, Dormitories",Barracks sleeping areas,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1, -"Hotels, Motels, Resorts, Dormitories",Lobbies/prefunction,7.5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1, -"Hotels, Motels, Resorts, Dormitories",Multi-purpose assembly,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1, -Office Buildings,Office space,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1, -Office Buildings,Reception areas,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1, -Office Buildings,Telephone/data entry,5,cfm/person,0.06,cfm/ft2,60,ppl/1000 ft2,1, -Office Buildings,Main entry lobbies,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1, -Miscellaneous Spaces,Bank vaults/safe deposit,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,2, -Miscellaneous Spaces,Computer (not printing),5,cfm/person,0.06,cfm/ft2,4,ppl/1000 ft2,1, -Miscellaneous Spaces,Pharmacy (prep. area),5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2, -Miscellaneous Spaces,Photo studios,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1, -Miscellaneous Spaces,Shipping/receiving,,cfm/person,0.12,cfm/ft2,,ppl/1000 ft2,1, -Miscellaneous Spaces,Transportation waiting,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1, -Miscellaneous Spaces,Warehouses,,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,2, -Public Assembly Spaces,Auditorium seating area,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1, -Public Assembly Spaces,Places of religious workshop,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1, -Public Assembly Spaces,Courtrooms,5,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1, -Public Assembly Spaces,Legislative chambers,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1, -Public Assembly Spaces,Libraries,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1, -Public Assembly Spaces,Lobbies,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1, -Public Assembly Spaces,Museums (children's),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1, -Public Assembly Spaces,Museums/galleries,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1, -Retail,Sales (except as below),7.5,cfm/person,0.12,cfm/ft2,15,ppl/1000 ft2,2, -Retail,Mall common areas,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1, -Retail,Barber shop,7.5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,2, -Retail,Beauty and nail salons,20,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2, -Retail,Pet shops (animal areas),7.5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2, -Retail,Supermarket,7.5,cfm/person,0.06,cfm/ft2,8,ppl/1000 ft2,1, -Retail,Coin-operated laundries,7.5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,2, -Sports and Entertainment,Sports arena (play area),,cfm/person,0.3,cfm/ft2,,ppl/1000 ft2,1, -Sports and Entertainment,"Gym, stadium (play area)",,cfm/person,0.3,cfm/ft2,30,ppl/1000 ft2,2, -Sports and Entertainment,Spectator areas,7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1, -Sports and Entertainment,Swimming (pool & deck),,cfm/person,0.48,cfm/ft2,,ppl/1000 ft2,2, -Sports and Entertainment,Disco/dance floors,20,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1, -Sports and Entertainment,Health club/aerobics room,20,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,2, -Sports and Entertainment,Health club/weight rooms,20,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,2, -Sports and Entertainment,Bowling alley (seating),10,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1, -Sports and Entertainment,Gambling casinos,7.5,cfm/person,0.18,cfm/ft2,120,ppl/1000 ft2,1, -Sports and Entertainment,Game arcades,7.5,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1, -Sports and Entertainment,"Stages, studios",10,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1, +ventilation_primary_space_type,ventilation_secondary_space_type,ventilation_per_person,ventilation_per_person_unit,ventilation_per_area,ventilation_per_area_unit,occupancy_per_area,occupancy_per_area_unit,air_class,os,annotation +Correctional Facilities,Cell,5,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, +Correctional Facilities,Day room,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, +Correctional Facilities,Guard stations,5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,, +Correctional Facilities,Booking/waiting,7.5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,2,, +Educational Facilities,Daycare (through age 4),10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, +Educational Facilities,Classrooms (ages 5-8),10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, +Educational Facilities,Classrooms (age 9 plus),10,cfm/person,0.12,cfm/ft2,35,ppl/1000 ft2,1,, +Educational Facilities,Lecture classroom,7.5,cfm/person,0.06,cfm/ft2,65,ppl/1000 ft2,1,, +Educational Facilities,Lecture hall (fixed seats),7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, +Educational Facilities,Art classroom,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, +Educational Facilities,Science laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,,, +Educational Facilities,Wood/metal shop,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, +Educational Facilities,Computer lab,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, +Educational Facilities,Media center,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, +Educational Facilities,Music/theater/dance,10,cfm/person,0.06,cfm/ft2,35,ppl/1000 ft2,1,, +Educational Facilities,Multi-use assembly,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, +Food and Beverage Service,Restaurant dining rooms,7.5,cfm/person,0.18,cfm/ft2,70,ppl/1000 ft2,2,, +Food and Beverage Service,Cafeteria/fast food dining,7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, +Food and Beverage Service,"Bars, cocktail lounges",7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, +General,Conference/meeting,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, +General,Corridors,,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,1,, +General,Storage rooms,,cfm/person,0.12,cfm/ft2,,ppl/1000 ft2,1,, +"Hotels, Motels, Resorts, Dormitories",Bedroom/living Room,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,, +"Hotels, Motels, Resorts, Dormitories",Barracks sleeping areas,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, +"Hotels, Motels, Resorts, Dormitories",Lobbies/prefunction,7.5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, +"Hotels, Motels, Resorts, Dormitories",Multi-purpose assembly,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,, +Office Buildings,Office space,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1,, +Office Buildings,Reception areas,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, +Office Buildings,Telephone/data entry,5,cfm/person,0.06,cfm/ft2,60,ppl/1000 ft2,1,, +Office Buildings,Main entry lobbies,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,, +Miscellaneous Spaces,Bank vaults/safe deposit,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,2,, +Miscellaneous Spaces,Computer (not printing),5,cfm/person,0.06,cfm/ft2,4,ppl/1000 ft2,1,, +Miscellaneous Spaces,Pharmacy (prep. area),5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, +Miscellaneous Spaces,Photo studios,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, +Miscellaneous Spaces,Shipping/receiving,,cfm/person,0.12,cfm/ft2,,ppl/1000 ft2,1,, +Miscellaneous Spaces,Transportation waiting,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, +Miscellaneous Spaces,Warehouses,,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,2,, +Public Assembly Spaces,Auditorium seating area,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, +Public Assembly Spaces,Places of religious workshop,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,, +Public Assembly Spaces,Courtrooms,5,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, +Public Assembly Spaces,Legislative chambers,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, +Public Assembly Spaces,Libraries,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, +Public Assembly Spaces,Lobbies,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, +Public Assembly Spaces,Museums (children's),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, +Public Assembly Spaces,Museums/galleries,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, +Retail,Sales (except as below),7.5,cfm/person,0.12,cfm/ft2,15,ppl/1000 ft2,2,, +Retail,Mall common areas,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, +Retail,Barber shop,7.5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,2,, +Retail,Beauty and nail salons,20,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, +Retail,Pet shops (animal areas),7.5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, +Retail,Supermarket,7.5,cfm/person,0.06,cfm/ft2,8,ppl/1000 ft2,1,, +Retail,Coin-operated laundries,7.5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,2,, +Sports and Entertainment,Sports arena (play area),,cfm/person,0.3,cfm/ft2,,ppl/1000 ft2,1,, +Sports and Entertainment,"Gym, stadium (play area)",,cfm/person,0.3,cfm/ft2,30,ppl/1000 ft2,2,, +Sports and Entertainment,Spectator areas,7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, +Sports and Entertainment,Swimming (pool & deck),,cfm/person,0.48,cfm/ft2,,ppl/1000 ft2,2,, +Sports and Entertainment,Disco/dance floors,20,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, +Sports and Entertainment,Health club/aerobics room,20,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,2,, +Sports and Entertainment,Health club/weight rooms,20,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,2,, +Sports and Entertainment,Bowling alley (seating),10,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, +Sports and Entertainment,Gambling casinos,7.5,cfm/person,0.18,cfm/ft2,120,ppl/1000 ft2,1,, +Sports and Entertainment,Game arcades,7.5,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, +Sports and Entertainment,"Stages, studios",10,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, diff --git a/data/openstudio_standards_data/initial_data/vent_def_62_1_2004.json b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2004.json similarity index 96% rename from data/openstudio_standards_data/initial_data/vent_def_62_1_2004.json rename to data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2004.json index 8571539cb4..7801abf6d5 100644 --- a/data/openstudio_standards_data/initial_data/vent_def_62_1_2004.json +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2004.json @@ -1,6 +1,5 @@ [ { - "id": 1, "ventilation_primary_space_type": "Correctional Facilities", "ventilation_secondary_space_type": "Cell", "ventilation_per_person": 5, @@ -14,7 +13,6 @@ "annotation": "" }, { - "id": 2, "ventilation_primary_space_type": "Correctional Facilities", "ventilation_secondary_space_type": "Day room", "ventilation_per_person": 5, @@ -28,7 +26,6 @@ "annotation": "" }, { - "id": 3, "ventilation_primary_space_type": "Correctional Facilities", "ventilation_secondary_space_type": "Guard stations", "ventilation_per_person": 5, @@ -42,7 +39,6 @@ "annotation": "" }, { - "id": 4, "ventilation_primary_space_type": "Correctional Facilities", "ventilation_secondary_space_type": "Booking/waiting", "ventilation_per_person": 7.5, @@ -56,7 +52,6 @@ "annotation": "" }, { - "id": 5, "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Daycare (through age 4)", "ventilation_per_person": 10, @@ -70,7 +65,6 @@ "annotation": "" }, { - "id": 6, "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Classrooms (ages 5-8)", "ventilation_per_person": 10, @@ -84,7 +78,6 @@ "annotation": "" }, { - "id": 7, "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Classrooms (age 9 plus)", "ventilation_per_person": 10, @@ -98,7 +91,6 @@ "annotation": "" }, { - "id": 8, "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Lecture classroom", "ventilation_per_person": 7.5, @@ -112,7 +104,6 @@ "annotation": "" }, { - "id": 9, "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Lecture hall (fixed seats)", "ventilation_per_person": 7.5, @@ -126,7 +117,6 @@ "annotation": "" }, { - "id": 10, "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Art classroom", "ventilation_per_person": 10, @@ -140,7 +130,6 @@ "annotation": "" }, { - "id": 11, "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Science laboratories", "ventilation_per_person": 10, @@ -154,7 +143,6 @@ "annotation": "" }, { - "id": 12, "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Wood/metal shop", "ventilation_per_person": 10, @@ -168,7 +156,6 @@ "annotation": "" }, { - "id": 13, "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Computer lab", "ventilation_per_person": 10, @@ -182,7 +169,6 @@ "annotation": "" }, { - "id": 14, "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Media center", "ventilation_per_person": 10, @@ -196,7 +182,6 @@ "annotation": "" }, { - "id": 15, "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Music/theater/dance", "ventilation_per_person": 10, @@ -210,7 +195,6 @@ "annotation": "" }, { - "id": 16, "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Multi-use assembly", "ventilation_per_person": 7.5, @@ -224,7 +208,6 @@ "annotation": "" }, { - "id": 17, "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Restaurant dining rooms", "ventilation_per_person": 7.5, @@ -238,7 +221,6 @@ "annotation": "" }, { - "id": 18, "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_person": 7.5, @@ -252,7 +234,6 @@ "annotation": "" }, { - "id": 19, "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Bars, cocktail lounges", "ventilation_per_person": 7.5, @@ -266,7 +247,6 @@ "annotation": "" }, { - "id": 20, "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Conference/meeting", "ventilation_per_person": 5, @@ -280,7 +260,6 @@ "annotation": "" }, { - "id": 21, "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_person": null, @@ -294,7 +273,6 @@ "annotation": "" }, { - "id": 22, "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_person": null, @@ -308,7 +286,6 @@ "annotation": "" }, { - "id": 23, "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_person": 5, @@ -322,7 +299,6 @@ "annotation": "" }, { - "id": 24, "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Barracks sleeping areas", "ventilation_per_person": 5, @@ -336,7 +312,6 @@ "annotation": "" }, { - "id": 25, "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies/prefunction", "ventilation_per_person": 7.5, @@ -350,7 +325,6 @@ "annotation": "" }, { - "id": 26, "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Multi-purpose assembly", "ventilation_per_person": 5, @@ -364,7 +338,6 @@ "annotation": "" }, { - "id": 27, "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_person": 5, @@ -378,7 +351,6 @@ "annotation": "" }, { - "id": 28, "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Reception areas", "ventilation_per_person": 5, @@ -392,7 +364,6 @@ "annotation": "" }, { - "id": 29, "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Telephone/data entry", "ventilation_per_person": 5, @@ -406,7 +377,6 @@ "annotation": "" }, { - "id": 30, "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Main entry lobbies", "ventilation_per_person": 5, @@ -420,7 +390,6 @@ "annotation": "" }, { - "id": 31, "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Bank vaults/safe deposit", "ventilation_per_person": 5, @@ -434,7 +403,6 @@ "annotation": "" }, { - "id": 32, "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Computer (not printing)", "ventilation_per_person": 5, @@ -448,7 +416,6 @@ "annotation": "" }, { - "id": 33, "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Pharmacy (prep. area)", "ventilation_per_person": 5, @@ -462,7 +429,6 @@ "annotation": "" }, { - "id": 34, "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Photo studios", "ventilation_per_person": 5, @@ -476,7 +442,6 @@ "annotation": "" }, { - "id": 35, "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Shipping/receiving", "ventilation_per_person": null, @@ -490,7 +455,6 @@ "annotation": "" }, { - "id": 36, "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Transportation waiting", "ventilation_per_person": 7.5, @@ -504,7 +468,6 @@ "annotation": "" }, { - "id": 37, "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Warehouses", "ventilation_per_person": null, @@ -518,7 +481,6 @@ "annotation": "" }, { - "id": 38, "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Auditorium seating area", "ventilation_per_person": 5, @@ -532,7 +494,6 @@ "annotation": "" }, { - "id": 39, "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Places of religious workshop", "ventilation_per_person": 5, @@ -546,7 +507,6 @@ "annotation": "" }, { - "id": 40, "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Courtrooms", "ventilation_per_person": 5, @@ -560,7 +520,6 @@ "annotation": "" }, { - "id": 41, "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Legislative chambers", "ventilation_per_person": 5, @@ -574,7 +533,6 @@ "annotation": "" }, { - "id": 42, "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Libraries", "ventilation_per_person": 5, @@ -588,7 +546,6 @@ "annotation": "" }, { - "id": 43, "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Lobbies", "ventilation_per_person": 5, @@ -602,9 +559,8 @@ "annotation": "" }, { - "id": 44, "ventilation_primary_space_type": "Public Assembly Spaces", - "ventilation_secondary_space_type": "Museums (children\u2019s)", + "ventilation_secondary_space_type": "Museums (children's)", "ventilation_per_person": 7.5, "ventilation_per_person_unit": "cfm/person", "ventilation_per_area": 0.12, @@ -616,7 +572,6 @@ "annotation": "" }, { - "id": 45, "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Museums/galleries", "ventilation_per_person": 7.5, @@ -630,7 +585,6 @@ "annotation": "" }, { - "id": 46, "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Sales (except as below)", "ventilation_per_person": 7.5, @@ -644,7 +598,6 @@ "annotation": "" }, { - "id": 47, "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Mall common areas", "ventilation_per_person": 7.5, @@ -658,7 +611,6 @@ "annotation": "" }, { - "id": 48, "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Barber shop", "ventilation_per_person": 7.5, @@ -672,7 +624,6 @@ "annotation": "" }, { - "id": 49, "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Beauty and nail salons", "ventilation_per_person": 20, @@ -686,7 +637,6 @@ "annotation": "" }, { - "id": 50, "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Pet shops (animal areas)", "ventilation_per_person": 7.5, @@ -700,7 +650,6 @@ "annotation": "" }, { - "id": 51, "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Supermarket", "ventilation_per_person": 7.5, @@ -714,7 +663,6 @@ "annotation": "" }, { - "id": 52, "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Coin-operated laundries", "ventilation_per_person": 7.5, @@ -728,7 +676,6 @@ "annotation": "" }, { - "id": 53, "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Sports arena (play area)", "ventilation_per_person": null, @@ -742,7 +689,6 @@ "annotation": "" }, { - "id": 54, "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Gym, stadium (play area)", "ventilation_per_person": null, @@ -756,7 +702,6 @@ "annotation": "" }, { - "id": 55, "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Spectator areas", "ventilation_per_person": 7.5, @@ -770,7 +715,6 @@ "annotation": "" }, { - "id": 56, "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Swimming (pool & deck)", "ventilation_per_person": null, @@ -784,7 +728,6 @@ "annotation": "" }, { - "id": 57, "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Disco/dance floors", "ventilation_per_person": 20, @@ -798,7 +741,6 @@ "annotation": "" }, { - "id": 58, "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Health club/aerobics room", "ventilation_per_person": 20, @@ -812,7 +754,6 @@ "annotation": "" }, { - "id": 59, "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Health club/weight rooms", "ventilation_per_person": 20, @@ -826,7 +767,6 @@ "annotation": "" }, { - "id": 60, "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Bowling alley (seating)", "ventilation_per_person": 10, @@ -840,7 +780,6 @@ "annotation": "" }, { - "id": 61, "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Gambling casinos", "ventilation_per_person": 7.5, @@ -854,7 +793,6 @@ "annotation": "" }, { - "id": 62, "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Game arcades", "ventilation_per_person": 7.5, @@ -868,7 +806,6 @@ "annotation": "" }, { - "id": 63, "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Stages, studios", "ventilation_per_person": 10, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.csv b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.csv index 424bb9367c..ba7be90ba7 100644 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.csv +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.csv @@ -1,110 +1,110 @@ -ventilation_primary_space_type,ventilation_secondary_space_type,ventilation_per_person,ventilation_per_person_unit,ventilation_per_area,ventilation_per_area_unit,occupancy_per_area,occupancy_per_area_unit,air_class,os -Animal Facilities,Animal exam room (veterinary office),10,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2, -Animal Facilities,Animal imaging (MRI/CT/PET),10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3, -Animal Facilities,Animal operating rooms,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3, -Animal Facilities,Animal postoperative recovery room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3, -Animal Facilities,Animal preparation rooms,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3, -Animal Facilities,Animal procedure room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3, -Animal Facilities,Animal surgery scrub,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3, -Animal Facilities,Large-animal holding room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3, -Animal Facilities,Necropsy,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3, -Animal Facilities,Small-animal-cage room (static cages),10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3, -Animal Facilities,Small-animal-cage room (ventilated cages),10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3, -Correctional Facilities,Booking/waiting,7.5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,2, -Correctional Facilities,Cell,5,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2, -Correctional Facilities,Dayroom,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1, -Correctional Facilities,Guard stations,5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1, -Educational Facilities,Art classroom,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2, -Educational Facilities,Classrooms (ages 5 to 8),10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1, -Educational Facilities,Classrooms (age 9 plus),10,cfm/person,0.12,cfm/ft2,35,ppl/1000 ft2,1, -Educational Facilities,Computer lab,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1, -Educational Facilities,Daycare sickroom,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,3, -Educational Facilities,Daycare (through age 4),10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2, -Educational Facilities,Lecture classroom,7.5,cfm/person,0.06,cfm/ft2,65,ppl/1000 ft2,1,yes -Educational Facilities,Lecture hall (fixed seats),7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,yes -Educational Facilities,Libraries (education),5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,, -Educational Facilities,Media center,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1, -Educational Facilities,Multiuse assembly,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,yes -Educational Facilities,Music/theater/dance,10,cfm/person,0.06,cfm/ft2,35,ppl/1000 ft2,1,yes -Educational Facilities,Science laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2, -Educational Facilities,University/college laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2, -Educational Facilities,Wood/metal shop,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2, -Food and Beverage Service,"Bars, cocktail lounges",7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2, -Food and Beverage Service,Cafeteria/fast-food dining,7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2, -Food and Beverage Service,Kitchen (cooking),7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2, -Food and Beverage Service,Restaurant dining rooms,7.5,cfm/person,0.18,cfm/ft2,70,ppl/1000 ft2,2, -"Food and Beverage Service, General",Break rooms,5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,1,yes -"Food and Beverage Service, General",Coffee stations,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,yes -"Food and Beverage Service, General",Conference/meeting,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,yes -"Food and Beverage Service, General",Corridors,,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,1,yes -"Food and Beverage Service, General",Occupiable storage rooms for liquids or gels,5,cfm/person,0.12,cfm/ft2,2,ppl/1000 ft2,2, -"Hotels, Motels, Resorts, Dormitories",Barracks sleeping areas,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,yes -"Hotels, Motels, Resorts, Dormitories",Bedroom/living room,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,yes -"Hotels, Motels, Resorts, Dormitories","Laundry rooms, central",5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,2, -"Hotels, Motels, Resorts, Dormitories",Laundry rooms within dwelling units,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1, -"Hotels, Motels, Resorts, Dormitories",Lobbies/prefunction,7.5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,yes -"Hotels, Motels, Resorts, Dormitories",Multipurpose assembly,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,yes -Miscellaneous Spaces,Banks or bank lobbies,7.5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,yes -Miscellaneous Spaces,Bank vaults/safe deposit,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,2,yes -Miscellaneous Spaces,Computer (not printing),5,cfm/person,0.06,cfm/ft2,4,ppl/1000 ft2,1,yes -Miscellaneous Spaces,Freezer and refrigerated spaces (<50�F [10�C]),10,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,2, -Miscellaneous Spaces,Manufacturing where hazardous materials are not used,10,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,2, -Miscellaneous Spaces,Manufacturing where hazardous materials are used (excludes heavy industrial and chemical processes),10,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,3, -Miscellaneous Spaces,Pharmacy (prep. area),5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2, -Miscellaneous Spaces,Photo studios,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1, -Miscellaneous Spaces,Shipping/receiving,10,cfm/person,0.12,cfm/ft2,2,ppl/1000 ft2,2, -Miscellaneous Spaces,"Sorting, packing, light assembly",7.5,cfm/person,0.12,cfm/ft2,7,ppl/1000 ft2,2, -Miscellaneous Spaces,Telephone closets,,cfm/person,0,cfm/ft2,,ppl/1000 ft2,1, -Miscellaneous Spaces,Transportation waiting,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,yes -Miscellaneous Spaces,Warehouses,10,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,2, -Office Buildings,Breakrooms,5,cfm/person,0.12,cfm/ft2,50,ppl/1000 ft2,1, -Office Buildings,Main entry lobbies,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,yes -Office Buildings,Occupiable storage rooms for dry materials,5,cfm/person,0.06,cfm/ft2,2,ppl/1000 ft2,1, -Office Buildings,Office space,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1,yes -Office Buildings,Reception areas,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,yes -Office Buildings,Telephone/data entry,5,cfm/person,0.06,cfm/ft2,60,ppl/1000 ft2,1,yes -Outpatient Health Care Facilities,Birthing room,10,cfm/person,0.18,cfm/ft2,15,ppl/1000 ft2,2, -Outpatient Health Care Facilities,Class 1 imaging rooms,5,cfm/person,0.12,cfm/ft2,5,ppl/1000 ft2,1, -Outpatient Health Care Facilities,Dental operatory,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1, -Outpatient Health Care Facilities,General examination room,7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,1, -Outpatient Health Care Facilities,Other dental treatment areas,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1, -Outpatient Health Care Facilities,Physical therapy exercise area,20,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,2, -Outpatient Health Care Facilities,Physical therapy individual room,10,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1, -Outpatient Health Care Facilities,Physical therapeutic pool area,,cfm/person,0.48,cfm/ft2,,ppl/1000 ft2,2, -Outpatient Health Care Facilities,Prosthetics and orthotics room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1, -Outpatient Health Care Facilities,Psychiatric consultation room,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1, -Outpatient Health Care Facilities,Psychiatric examination room,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1, -Outpatient Health Care Facilities,Psychiatric group room,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1, -Outpatient Health Care Facilities,Psychiatric seclusion room,10,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1, -Outpatient Health Care Facilities,Speech therapy room,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1, -Outpatient Health Care Facilities,Urgent care examination room,7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,1, -Outpatient Health Care Facilities,Urgent care observation room,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1, -Outpatient Health Care Facilities,Urgent care treatment room,7.5,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1, -Outpatient Health Care Facilities,Urgent care triage room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1, -Public Assembly Spaces,Auditorium seating area,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,yes -Public Assembly Spaces,Courtrooms,5,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,yes -Public Assembly Spaces,Legislative chambers,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,yes -Public Assembly Spaces,Libraries (public assembly),5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1, -Public Assembly Spaces,Lobbies,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,yes -Public Assembly Spaces,Museums (children's),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1, -Public Assembly Spaces,Museums/galleries,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,yes -Public Assembly Spaces,Places of religious worship,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,yes -Retail,Sales (except as below),7.5,cfm/person,0.12,cfm/ft2,15,ppl/1000 ft2,2, -Retail,Barbershop,7.5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,2,yes -Retail,Beauty and nail salons,20,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2, -Retail,Coin-operated laundries,7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2, -Retail,Mall common areas,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,yes -Retail,Pet shops (animal areas),7.5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2, -Retail,Supermarket,7.5,cfm/person,0.06,cfm/ft2,8,ppl/1000 ft2,1,yes -Sports and Entertainment,Bowling alley (seating),10,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1, -Sports and Entertainment,Disco/dance floors,20,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,2,yes -Sports and Entertainment,Gambling casinos,7.5,cfm/person,0.18,cfm/ft2,120,ppl/1000 ft2,1, -Sports and Entertainment,Game arcades,7.5,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1, -Sports and Entertainment,"Gym, sports arena (play area)",20,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,2, -Sports and Entertainment,Health club/aerobics room,20,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,2, -Sports and Entertainment,Health club/weight rooms,20,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,2, -Sports and Entertainment,Spectator areas,7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,yes -Sports and Entertainment,"Stages, studios",10,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,yes -Sports and Entertainment,Swimming (pool and deck),,cfm/person,0.48,cfm/ft2,,ppl/1000 ft2,2, -Transient Residential,Common corridors,,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,1,yes -Transient Residential,Dwelling unit,5,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,1,yes +ventilation_primary_space_type,ventilation_secondary_space_type,ventilation_per_person,ventilation_per_person_unit,ventilation_per_area,ventilation_per_area_unit,occupancy_per_area,occupancy_per_area_unit,air_class,os,annotation +Animal Facilities,Animal exam room (veterinary office),10,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2,, +Animal Facilities,Animal imaging (MRI/CT/PET),10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, +Animal Facilities,Animal operating rooms,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, +Animal Facilities,Animal postoperative recovery room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, +Animal Facilities,Animal preparation rooms,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, +Animal Facilities,Animal procedure room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, +Animal Facilities,Animal surgery scrub,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, +Animal Facilities,Large-animal holding room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, +Animal Facilities,Necropsy,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, +Animal Facilities,Small-animal-cage room (static cages),10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, +Animal Facilities,Small-animal-cage room (ventilated cages),10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, +Correctional Facilities,Booking/waiting,7.5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,2,, +Correctional Facilities,Cell,5,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, +Correctional Facilities,Dayroom,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, +Correctional Facilities,Guard stations,5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,, +Educational Facilities,Art classroom,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, +Educational Facilities,Classrooms (ages 5 to 8),10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, +Educational Facilities,Classrooms (age 9 plus),10,cfm/person,0.12,cfm/ft2,35,ppl/1000 ft2,1,, +Educational Facilities,Computer lab,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, +Educational Facilities,Daycare sickroom,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,3,, +Educational Facilities,Daycare (through age 4),10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, +Educational Facilities,Lecture classroom,7.5,cfm/person,0.06,cfm/ft2,65,ppl/1000 ft2,1,yes, +Educational Facilities,Lecture hall (fixed seats),7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,yes, +Educational Facilities,Libraries (education),5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,,, +Educational Facilities,Media center,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, +Educational Facilities,Multiuse assembly,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,yes, +Educational Facilities,Music/theater/dance,10,cfm/person,0.06,cfm/ft2,35,ppl/1000 ft2,1,yes, +Educational Facilities,Science laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, +Educational Facilities,University/college laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, +Educational Facilities,Wood/metal shop,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, +Food and Beverage Service,"Bars, cocktail lounges",7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, +Food and Beverage Service,Cafeteria/fast-food dining,7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, +Food and Beverage Service,Kitchen (cooking),7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2,, +Food and Beverage Service,Restaurant dining rooms,7.5,cfm/person,0.18,cfm/ft2,70,ppl/1000 ft2,2,, +"Food and Beverage Service, General",Break rooms,5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,1,yes, +"Food and Beverage Service, General",Coffee stations,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,yes, +"Food and Beverage Service, General",Conference/meeting,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,yes, +"Food and Beverage Service, General",Corridors,,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,1,yes, +"Food and Beverage Service, General",Occupiable storage rooms for liquids or gels,5,cfm/person,0.12,cfm/ft2,2,ppl/1000 ft2,2,, +"Hotels, Motels, Resorts, Dormitories",Barracks sleeping areas,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,yes, +"Hotels, Motels, Resorts, Dormitories",Bedroom/living room,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,yes, +"Hotels, Motels, Resorts, Dormitories","Laundry rooms, central",5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,2,, +"Hotels, Motels, Resorts, Dormitories",Laundry rooms within dwelling units,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, +"Hotels, Motels, Resorts, Dormitories",Lobbies/prefunction,7.5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,yes, +"Hotels, Motels, Resorts, Dormitories",Multipurpose assembly,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,yes, +Miscellaneous Spaces,Banks or bank lobbies,7.5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,yes, +Miscellaneous Spaces,Bank vaults/safe deposit,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,2,yes, +Miscellaneous Spaces,Computer (not printing),5,cfm/person,0.06,cfm/ft2,4,ppl/1000 ft2,1,yes, +Miscellaneous Spaces,Freezer and refrigerated spaces (<50�F [10�C]),10,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,2,, +Miscellaneous Spaces,Manufacturing where hazardous materials are not used,10,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,2,, +Miscellaneous Spaces,Manufacturing where hazardous materials are used (excludes heavy industrial and chemical processes),10,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,3,, +Miscellaneous Spaces,Pharmacy (prep. area),5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, +Miscellaneous Spaces,Photo studios,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, +Miscellaneous Spaces,Shipping/receiving,10,cfm/person,0.12,cfm/ft2,2,ppl/1000 ft2,2,, +Miscellaneous Spaces,"Sorting, packing, light assembly",7.5,cfm/person,0.12,cfm/ft2,7,ppl/1000 ft2,2,, +Miscellaneous Spaces,Telephone closets,,cfm/person,0,cfm/ft2,,ppl/1000 ft2,1,, +Miscellaneous Spaces,Transportation waiting,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,yes, +Miscellaneous Spaces,Warehouses,10,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,2,, +Office Buildings,Breakrooms,5,cfm/person,0.12,cfm/ft2,50,ppl/1000 ft2,1,, +Office Buildings,Main entry lobbies,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,yes, +Office Buildings,Occupiable storage rooms for dry materials,5,cfm/person,0.06,cfm/ft2,2,ppl/1000 ft2,1,, +Office Buildings,Office space,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1,yes, +Office Buildings,Reception areas,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,yes, +Office Buildings,Telephone/data entry,5,cfm/person,0.06,cfm/ft2,60,ppl/1000 ft2,1,yes, +Outpatient Health Care Facilities,Birthing room,10,cfm/person,0.18,cfm/ft2,15,ppl/1000 ft2,2,, +Outpatient Health Care Facilities,Class 1 imaging rooms,5,cfm/person,0.12,cfm/ft2,5,ppl/1000 ft2,1,, +Outpatient Health Care Facilities,Dental operatory,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, +Outpatient Health Care Facilities,General examination room,7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,1,, +Outpatient Health Care Facilities,Other dental treatment areas,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1,, +Outpatient Health Care Facilities,Physical therapy exercise area,20,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,2,, +Outpatient Health Care Facilities,Physical therapy individual room,10,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, +Outpatient Health Care Facilities,Physical therapeutic pool area,,cfm/person,0.48,cfm/ft2,,ppl/1000 ft2,2,, +Outpatient Health Care Facilities,Prosthetics and orthotics room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, +Outpatient Health Care Facilities,Psychiatric consultation room,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, +Outpatient Health Care Facilities,Psychiatric examination room,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, +Outpatient Health Care Facilities,Psychiatric group room,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, +Outpatient Health Care Facilities,Psychiatric seclusion room,10,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1,, +Outpatient Health Care Facilities,Speech therapy room,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, +Outpatient Health Care Facilities,Urgent care examination room,7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,1,, +Outpatient Health Care Facilities,Urgent care observation room,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, +Outpatient Health Care Facilities,Urgent care treatment room,7.5,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, +Outpatient Health Care Facilities,Urgent care triage room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, +Public Assembly Spaces,Auditorium seating area,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,yes, +Public Assembly Spaces,Courtrooms,5,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,yes, +Public Assembly Spaces,Legislative chambers,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,yes, +Public Assembly Spaces,Libraries (public assembly),5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, +Public Assembly Spaces,Lobbies,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,yes, +Public Assembly Spaces,Museums (children's),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, +Public Assembly Spaces,Museums/galleries,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,yes, +Public Assembly Spaces,Places of religious worship,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,yes, +Retail,Sales (except as below),7.5,cfm/person,0.12,cfm/ft2,15,ppl/1000 ft2,2,, +Retail,Barbershop,7.5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,2,yes, +Retail,Beauty and nail salons,20,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, +Retail,Coin-operated laundries,7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2,, +Retail,Mall common areas,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,yes, +Retail,Pet shops (animal areas),7.5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, +Retail,Supermarket,7.5,cfm/person,0.06,cfm/ft2,8,ppl/1000 ft2,1,yes, +Sports and Entertainment,Bowling alley (seating),10,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, +Sports and Entertainment,Disco/dance floors,20,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,2,yes, +Sports and Entertainment,Gambling casinos,7.5,cfm/person,0.18,cfm/ft2,120,ppl/1000 ft2,1,, +Sports and Entertainment,Game arcades,7.5,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, +Sports and Entertainment,"Gym, sports arena (play area)",20,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,2,, +Sports and Entertainment,Health club/aerobics room,20,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,2,, +Sports and Entertainment,Health club/weight rooms,20,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,2,, +Sports and Entertainment,Spectator areas,7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,yes, +Sports and Entertainment,"Stages, studios",10,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,yes, +Sports and Entertainment,Swimming (pool and deck),,cfm/person,0.48,cfm/ft2,,ppl/1000 ft2,2,, +Transient Residential,Common corridors,,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,1,yes, +Transient Residential,Dwelling unit,5,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,1,yes, diff --git a/data/openstudio_standards_data/initial_data/vent_def_62_1_2019.json b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.json similarity index 96% rename from data/openstudio_standards_data/initial_data/vent_def_62_1_2019.json rename to data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.json index 49c385b12b..853a4b3469 100644 --- a/data/openstudio_standards_data/initial_data/vent_def_62_1_2019.json +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.json @@ -1,6 +1,5 @@ [ { - "id": 1, "ventilation_primary_space_type": "Animal Facilities", "ventilation_secondary_space_type": "Animal exam room (veterinary office)", "ventilation_per_person": 10, @@ -14,7 +13,6 @@ "annotation": "" }, { - "id": 2, "ventilation_primary_space_type": "Animal Facilities", "ventilation_secondary_space_type": "Animal imaging (MRI/CT/PET)", "ventilation_per_person": 10, @@ -28,7 +26,6 @@ "annotation": "" }, { - "id": 3, "ventilation_primary_space_type": "Animal Facilities", "ventilation_secondary_space_type": "Animal operating rooms", "ventilation_per_person": 10, @@ -42,7 +39,6 @@ "annotation": "" }, { - "id": 4, "ventilation_primary_space_type": "Animal Facilities", "ventilation_secondary_space_type": "Animal postoperative recovery room", "ventilation_per_person": 10, @@ -56,7 +52,6 @@ "annotation": "" }, { - "id": 5, "ventilation_primary_space_type": "Animal Facilities", "ventilation_secondary_space_type": "Animal preparation rooms", "ventilation_per_person": 10, @@ -70,7 +65,6 @@ "annotation": "" }, { - "id": 6, "ventilation_primary_space_type": "Animal Facilities", "ventilation_secondary_space_type": "Animal procedure room", "ventilation_per_person": 10, @@ -84,7 +78,6 @@ "annotation": "" }, { - "id": 7, "ventilation_primary_space_type": "Animal Facilities", "ventilation_secondary_space_type": "Animal surgery scrub", "ventilation_per_person": 10, @@ -98,7 +91,6 @@ "annotation": "" }, { - "id": 8, "ventilation_primary_space_type": "Animal Facilities", "ventilation_secondary_space_type": "Large-animal holding room", "ventilation_per_person": 10, @@ -112,7 +104,6 @@ "annotation": "" }, { - "id": 9, "ventilation_primary_space_type": "Animal Facilities", "ventilation_secondary_space_type": "Necropsy", "ventilation_per_person": 10, @@ -126,7 +117,6 @@ "annotation": "" }, { - "id": 10, "ventilation_primary_space_type": "Animal Facilities", "ventilation_secondary_space_type": "Small-animal-cage room (static cages)", "ventilation_per_person": 10, @@ -140,7 +130,6 @@ "annotation": "" }, { - "id": 11, "ventilation_primary_space_type": "Animal Facilities", "ventilation_secondary_space_type": "Small-animal-cage room (ventilated cages)", "ventilation_per_person": 10, @@ -154,7 +143,6 @@ "annotation": "" }, { - "id": 12, "ventilation_primary_space_type": "Correctional Facilities", "ventilation_secondary_space_type": "Booking/waiting", "ventilation_per_person": 7.5, @@ -168,7 +156,6 @@ "annotation": "" }, { - "id": 13, "ventilation_primary_space_type": "Correctional Facilities", "ventilation_secondary_space_type": "Cell", "ventilation_per_person": 5, @@ -182,7 +169,6 @@ "annotation": "" }, { - "id": 14, "ventilation_primary_space_type": "Correctional Facilities", "ventilation_secondary_space_type": "Dayroom", "ventilation_per_person": 5, @@ -196,7 +182,6 @@ "annotation": "" }, { - "id": 15, "ventilation_primary_space_type": "Correctional Facilities", "ventilation_secondary_space_type": "Guard stations", "ventilation_per_person": 5, @@ -210,7 +195,6 @@ "annotation": "" }, { - "id": 16, "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Art classroom", "ventilation_per_person": 10, @@ -224,7 +208,6 @@ "annotation": "" }, { - "id": 17, "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Classrooms (ages 5 to 8)", "ventilation_per_person": 10, @@ -238,7 +221,6 @@ "annotation": "" }, { - "id": 18, "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Classrooms (age 9 plus)", "ventilation_per_person": 10, @@ -252,7 +234,6 @@ "annotation": "" }, { - "id": 19, "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Computer lab", "ventilation_per_person": 10, @@ -266,7 +247,6 @@ "annotation": "" }, { - "id": 20, "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Daycare sickroom", "ventilation_per_person": 10, @@ -280,7 +260,6 @@ "annotation": "" }, { - "id": 21, "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Daycare (through age 4)", "ventilation_per_person": 10, @@ -294,7 +273,6 @@ "annotation": "" }, { - "id": 22, "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Lecture classroom", "ventilation_per_person": 7.5, @@ -308,7 +286,6 @@ "annotation": "" }, { - "id": 23, "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Lecture hall (fixed seats)", "ventilation_per_person": 7.5, @@ -322,7 +299,6 @@ "annotation": "" }, { - "id": 24, "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Libraries (education)", "ventilation_per_person": 5, @@ -336,7 +312,6 @@ "annotation": "" }, { - "id": 25, "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Media center", "ventilation_per_person": 10, @@ -350,7 +325,6 @@ "annotation": "" }, { - "id": 26, "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Multiuse assembly", "ventilation_per_person": 7.5, @@ -364,7 +338,6 @@ "annotation": "" }, { - "id": 27, "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Music/theater/dance", "ventilation_per_person": 10, @@ -378,7 +351,6 @@ "annotation": "" }, { - "id": 28, "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Science laboratories", "ventilation_per_person": 10, @@ -392,7 +364,6 @@ "annotation": "" }, { - "id": 29, "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "University/college laboratories", "ventilation_per_person": 10, @@ -406,7 +377,6 @@ "annotation": "" }, { - "id": 30, "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Wood/metal shop", "ventilation_per_person": 10, @@ -420,7 +390,6 @@ "annotation": "" }, { - "id": 31, "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Bars, cocktail lounges", "ventilation_per_person": 7.5, @@ -434,7 +403,6 @@ "annotation": "" }, { - "id": 32, "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast-food dining", "ventilation_per_person": 7.5, @@ -448,7 +416,6 @@ "annotation": "" }, { - "id": 33, "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Kitchen (cooking)", "ventilation_per_person": 7.5, @@ -462,7 +429,6 @@ "annotation": "" }, { - "id": 34, "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Restaurant dining rooms", "ventilation_per_person": 7.5, @@ -476,7 +442,6 @@ "annotation": "" }, { - "id": 35, "ventilation_primary_space_type": "Food and Beverage Service, General", "ventilation_secondary_space_type": "Break rooms", "ventilation_per_person": 5, @@ -490,7 +455,6 @@ "annotation": "" }, { - "id": 36, "ventilation_primary_space_type": "Food and Beverage Service, General", "ventilation_secondary_space_type": "Coffee stations", "ventilation_per_person": 5, @@ -504,7 +468,6 @@ "annotation": "" }, { - "id": 37, "ventilation_primary_space_type": "Food and Beverage Service, General", "ventilation_secondary_space_type": "Conference/meeting", "ventilation_per_person": 5, @@ -518,7 +481,6 @@ "annotation": "" }, { - "id": 38, "ventilation_primary_space_type": "Food and Beverage Service, General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_person": null, @@ -532,7 +494,6 @@ "annotation": "" }, { - "id": 39, "ventilation_primary_space_type": "Food and Beverage Service, General", "ventilation_secondary_space_type": "Occupiable storage rooms for liquids or gels", "ventilation_per_person": 5, @@ -546,7 +507,6 @@ "annotation": "" }, { - "id": 40, "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Barracks sleeping areas", "ventilation_per_person": 5, @@ -560,7 +520,6 @@ "annotation": "" }, { - "id": 41, "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living room", "ventilation_per_person": 5, @@ -574,7 +533,6 @@ "annotation": "" }, { - "id": 42, "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Laundry rooms, central", "ventilation_per_person": 5, @@ -588,7 +546,6 @@ "annotation": "" }, { - "id": 43, "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Laundry rooms within dwelling units", "ventilation_per_person": 5, @@ -602,7 +559,6 @@ "annotation": "" }, { - "id": 44, "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies/prefunction", "ventilation_per_person": 7.5, @@ -616,7 +572,6 @@ "annotation": "" }, { - "id": 45, "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Multipurpose assembly", "ventilation_per_person": 5, @@ -630,7 +585,6 @@ "annotation": "" }, { - "id": 46, "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Banks or bank lobbies", "ventilation_per_person": 7.5, @@ -644,7 +598,6 @@ "annotation": "" }, { - "id": 47, "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Bank vaults/safe deposit", "ventilation_per_person": 5, @@ -658,7 +611,6 @@ "annotation": "" }, { - "id": 48, "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Computer (not printing)", "ventilation_per_person": 5, @@ -672,9 +624,8 @@ "annotation": "" }, { - "id": 49, "ventilation_primary_space_type": "Miscellaneous Spaces", - "ventilation_secondary_space_type": "Freezer and refrigerated spaces (<50\u00b0F [10\u00b0C])", + "ventilation_secondary_space_type": "Freezer and refrigerated spaces (<50\u00ef\u00bf\u00bdF [10\u00ef\u00bf\u00bdC])", "ventilation_per_person": 10, "ventilation_per_person_unit": "cfm/person", "ventilation_per_area": 0, @@ -686,7 +637,6 @@ "annotation": "" }, { - "id": 50, "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Manufacturing where hazardous materials are not used", "ventilation_per_person": 10, @@ -700,7 +650,6 @@ "annotation": "" }, { - "id": 51, "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Manufacturing where hazardous materials are used (excludes heavy industrial and chemical processes)", "ventilation_per_person": 10, @@ -714,7 +663,6 @@ "annotation": "" }, { - "id": 52, "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Pharmacy (prep. area)", "ventilation_per_person": 5, @@ -728,7 +676,6 @@ "annotation": "" }, { - "id": 53, "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Photo studios", "ventilation_per_person": 5, @@ -742,7 +689,6 @@ "annotation": "" }, { - "id": 54, "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Shipping/receiving", "ventilation_per_person": 10, @@ -756,7 +702,6 @@ "annotation": "" }, { - "id": 55, "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Sorting, packing, light assembly", "ventilation_per_person": 7.5, @@ -770,7 +715,6 @@ "annotation": "" }, { - "id": 56, "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Telephone closets", "ventilation_per_person": null, @@ -784,7 +728,6 @@ "annotation": "" }, { - "id": 57, "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Transportation waiting", "ventilation_per_person": 7.5, @@ -798,7 +741,6 @@ "annotation": "" }, { - "id": 58, "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Warehouses", "ventilation_per_person": 10, @@ -812,7 +754,6 @@ "annotation": "" }, { - "id": 59, "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Breakrooms", "ventilation_per_person": 5, @@ -826,7 +767,6 @@ "annotation": "" }, { - "id": 60, "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Main entry lobbies", "ventilation_per_person": 5, @@ -840,7 +780,6 @@ "annotation": "" }, { - "id": 61, "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Occupiable storage rooms for dry materials", "ventilation_per_person": 5, @@ -854,7 +793,6 @@ "annotation": "" }, { - "id": 62, "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_person": 5, @@ -868,7 +806,6 @@ "annotation": "" }, { - "id": 63, "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Reception areas", "ventilation_per_person": 5, @@ -882,7 +819,6 @@ "annotation": "" }, { - "id": 64, "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Telephone/data entry", "ventilation_per_person": 5, @@ -896,7 +832,6 @@ "annotation": "" }, { - "id": 65, "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Birthing room", "ventilation_per_person": 10, @@ -910,7 +845,6 @@ "annotation": "" }, { - "id": 66, "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Class 1 imaging rooms", "ventilation_per_person": 5, @@ -924,7 +858,6 @@ "annotation": "" }, { - "id": 67, "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Dental operatory", "ventilation_per_person": 10, @@ -938,7 +871,6 @@ "annotation": "" }, { - "id": 68, "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "General examination room", "ventilation_per_person": 7.5, @@ -952,7 +884,6 @@ "annotation": "" }, { - "id": 69, "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Other dental treatment areas", "ventilation_per_person": 5, @@ -966,7 +897,6 @@ "annotation": "" }, { - "id": 70, "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Physical therapy exercise area", "ventilation_per_person": 20, @@ -980,7 +910,6 @@ "annotation": "" }, { - "id": 71, "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Physical therapy individual room", "ventilation_per_person": 10, @@ -994,7 +923,6 @@ "annotation": "" }, { - "id": 72, "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Physical therapeutic pool area", "ventilation_per_person": null, @@ -1008,7 +936,6 @@ "annotation": "" }, { - "id": 73, "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Prosthetics and orthotics room", "ventilation_per_person": 10, @@ -1022,7 +949,6 @@ "annotation": "" }, { - "id": 74, "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Psychiatric consultation room", "ventilation_per_person": 5, @@ -1036,7 +962,6 @@ "annotation": "" }, { - "id": 75, "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Psychiatric examination room", "ventilation_per_person": 5, @@ -1050,7 +975,6 @@ "annotation": "" }, { - "id": 76, "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Psychiatric group room", "ventilation_per_person": 5, @@ -1064,7 +988,6 @@ "annotation": "" }, { - "id": 77, "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Psychiatric seclusion room", "ventilation_per_person": 10, @@ -1078,7 +1001,6 @@ "annotation": "" }, { - "id": 78, "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Speech therapy room", "ventilation_per_person": 5, @@ -1092,7 +1014,6 @@ "annotation": "" }, { - "id": 79, "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Urgent care examination room", "ventilation_per_person": 7.5, @@ -1106,7 +1027,6 @@ "annotation": "" }, { - "id": 80, "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Urgent care observation room", "ventilation_per_person": 5, @@ -1120,7 +1040,6 @@ "annotation": "" }, { - "id": 81, "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Urgent care treatment room", "ventilation_per_person": 7.5, @@ -1134,7 +1053,6 @@ "annotation": "" }, { - "id": 82, "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Urgent care triage room", "ventilation_per_person": 10, @@ -1148,7 +1066,6 @@ "annotation": "" }, { - "id": 83, "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Auditorium seating area", "ventilation_per_person": 5, @@ -1162,7 +1079,6 @@ "annotation": "" }, { - "id": 84, "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Courtrooms", "ventilation_per_person": 5, @@ -1176,7 +1092,6 @@ "annotation": "" }, { - "id": 85, "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Legislative chambers", "ventilation_per_person": 5, @@ -1190,7 +1105,6 @@ "annotation": "" }, { - "id": 86, "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Libraries (public assembly)", "ventilation_per_person": 5, @@ -1204,7 +1118,6 @@ "annotation": "" }, { - "id": 87, "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Lobbies", "ventilation_per_person": 5, @@ -1218,9 +1131,8 @@ "annotation": "" }, { - "id": 88, "ventilation_primary_space_type": "Public Assembly Spaces", - "ventilation_secondary_space_type": "Museums (children\u2019s)", + "ventilation_secondary_space_type": "Museums (children's)", "ventilation_per_person": 7.5, "ventilation_per_person_unit": "cfm/person", "ventilation_per_area": 0.12, @@ -1232,7 +1144,6 @@ "annotation": "" }, { - "id": 89, "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Museums/galleries", "ventilation_per_person": 7.5, @@ -1246,7 +1157,6 @@ "annotation": "" }, { - "id": 90, "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Places of religious worship", "ventilation_per_person": 5, @@ -1260,7 +1170,6 @@ "annotation": "" }, { - "id": 91, "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Sales (except as below)", "ventilation_per_person": 7.5, @@ -1274,7 +1183,6 @@ "annotation": "" }, { - "id": 92, "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Barbershop", "ventilation_per_person": 7.5, @@ -1288,7 +1196,6 @@ "annotation": "" }, { - "id": 93, "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Beauty and nail salons", "ventilation_per_person": 20, @@ -1302,7 +1209,6 @@ "annotation": "" }, { - "id": 94, "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Coin-operated laundries", "ventilation_per_person": 7.5, @@ -1316,7 +1222,6 @@ "annotation": "" }, { - "id": 95, "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Mall common areas", "ventilation_per_person": 7.5, @@ -1330,7 +1235,6 @@ "annotation": "" }, { - "id": 96, "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Pet shops (animal areas)", "ventilation_per_person": 7.5, @@ -1344,7 +1248,6 @@ "annotation": "" }, { - "id": 97, "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Supermarket", "ventilation_per_person": 7.5, @@ -1358,7 +1261,6 @@ "annotation": "" }, { - "id": 98, "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Bowling alley (seating)", "ventilation_per_person": 10, @@ -1372,7 +1274,6 @@ "annotation": "" }, { - "id": 99, "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Disco/dance floors", "ventilation_per_person": 20, @@ -1386,7 +1287,6 @@ "annotation": "" }, { - "id": 100, "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Gambling casinos", "ventilation_per_person": 7.5, @@ -1400,7 +1300,6 @@ "annotation": "" }, { - "id": 101, "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Game arcades", "ventilation_per_person": 7.5, @@ -1414,7 +1313,6 @@ "annotation": "" }, { - "id": 102, "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Gym, sports arena (play area)", "ventilation_per_person": 20, @@ -1428,7 +1326,6 @@ "annotation": "" }, { - "id": 103, "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Health club/aerobics room", "ventilation_per_person": 20, @@ -1442,7 +1339,6 @@ "annotation": "" }, { - "id": 104, "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Health club/weight rooms", "ventilation_per_person": 20, @@ -1456,7 +1352,6 @@ "annotation": "" }, { - "id": 105, "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Spectator areas", "ventilation_per_person": 7.5, @@ -1470,7 +1365,6 @@ "annotation": "" }, { - "id": 106, "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Stages, studios", "ventilation_per_person": 10, @@ -1484,7 +1378,6 @@ "annotation": "" }, { - "id": 107, "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Swimming (pool and deck)", "ventilation_per_person": null, @@ -1498,7 +1391,6 @@ "annotation": "" }, { - "id": 108, "ventilation_primary_space_type": "Transient Residential", "ventilation_secondary_space_type": "Common corridors", "ventilation_per_person": null, @@ -1512,7 +1404,6 @@ "annotation": "" }, { - "id": 109, "ventilation_primary_space_type": "Transient Residential", "ventilation_secondary_space_type": "Dwelling unit", "ventilation_per_person": 5, diff --git a/data/openstudio_standards_data/database_files/support_constructions.csv b/data/openstudio_standards_data/database_files/support_constructions.csv index be2b48475b..add7bb239f 100644 --- a/data/openstudio_standards_data/database_files/support_constructions.csv +++ b/data/openstudio_standards_data/database_files/support_constructions.csv @@ -1,4 +1,4 @@ -name,intended_surface_type,standard_construction_type,insulation_layer,skylight_framing,material_1,material_2,material_3,material_4,material_5,material_6 +name,intended_surface_type,standards_construction_type,insulation_layer,skylight_framing,material_1,material_2,material_3,material_4,material_5,material_6 Typical Attic Floor,AtticFloor,WoodFramed,Typical Insulation,,1/2IN Gypsum,Typical Insulation,1/2IN Gypsum,,, Typical Wood Joist Attic Floor,AtticFloor,WoodFramed,Typical Insulation,,5/8 in. Gypsum Board,Typical Insulation,,,, Typical Wood Joist Attic Floor Ceiling,AtticFloor,WoodFramed,,,Typical Insulation,5/8 in. Gypsum Board,,,, diff --git a/data/openstudio_standards_data/database_files/support_constructions.json b/data/openstudio_standards_data/database_files/support_constructions.json new file mode 100644 index 0000000000..72a9a4d791 --- /dev/null +++ b/data/openstudio_standards_data/database_files/support_constructions.json @@ -0,0 +1,6385 @@ +[ + { + "name": "Typical Attic Floor", + "intended_surface_type": "AtticFloor", + "standards_construction_type": "WoodFramed", + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "1/2IN Gypsum", + "material_2": "Typical Insulation", + "material_3": "1/2IN Gypsum", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Wood Joist Attic Floor", + "intended_surface_type": "AtticFloor", + "standards_construction_type": "WoodFramed", + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "5/8 in. Gypsum Board", + "material_2": "Typical Insulation", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Wood Joist Attic Floor Ceiling", + "intended_surface_type": "AtticFloor", + "standards_construction_type": "WoodFramed", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Typical Insulation", + "material_2": "5/8 in. Gypsum Board", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Uninsulated Metal Roof Attic Roof", + "intended_surface_type": "AtticRoof", + "standards_construction_type": "WoodFramed", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Roof Membrane", + "material_2": "Metal Decking", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Uninsulated Wood Joist Attic Roof", + "intended_surface_type": "AtticRoof", + "standards_construction_type": "WoodFramed", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Asphalt Shingles", + "material_2": "5/8 in. Plywood", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Attic Soffit", + "intended_surface_type": "AtticWall", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "5/8 in. Plywood", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Insulated Metal Door", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": null, + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "F08 Metal surface", + "material_2": "Typical Insulation", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Overhead Door", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "RollUp", + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Typical Insulation", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Uninsulated Swinging Door", + "intended_surface_type": "ExteriorDoor", + "standards_construction_type": "Swinging", + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Typical Insulation", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Adiabatic ExteriorFloor", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Adiabatic Material", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Carpeted 4in Slab Floor", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "MAT-CC05 4 HW CONCRETE", + "material_2": "Typical Carpet Pad", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Insulated Carpeted 4in Slab Floor", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": null, + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Typical Insulation", + "material_2": "MAT-CC05 4 HW CONCRETE", + "material_3": "Typical Carpet Pad", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Insulated Exterior Mass Floor", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Typical Insulation", + "material_2": "4 in. Normalweight Concrete Floor", + "material_3": "Typical Carpet Pad", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Insulated Exterior Mass Floor Ceiling", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "Mass", + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Typical Carpet Pad", + "material_2": "4 in. Normalweight Concrete Floor", + "material_3": "Typical Insulation", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Insulated Steel Framed Exterior Floor", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "SteelFramed", + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "25mm Stucco", + "material_2": "5/8 in. Gypsum Board", + "material_3": "Typical Insulation", + "material_4": "5/8 in. Gypsum Board", + "material_5": "Typical Carpet Pad", + "material_6": null + }, + { + "name": "Typical Insulated Wood Framed Exterior Floor", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": "WoodFramed", + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "25mm Stucco", + "material_2": "5/8 in. Gypsum Board", + "material_3": "Typical Insulation", + "material_4": "5/8 in. Gypsum Board", + "material_5": "Typical Carpet Pad", + "material_6": null + }, + { + "name": "Typical Uncarpeted 4in Slab Floor", + "intended_surface_type": "ExteriorFloor", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "MAT-CC05 4 HW CONCRETE", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Adiabatic Roof", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Attic and Other", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Adiabatic Material", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Metal roofR_R30", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": null, + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Metal Standing Seam - 1/16 in. CBES", + "material_2": "R_R30", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Metal roofR_R38", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": null, + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Metal Standing Seam - 1/16 in. CBES", + "material_2": "R_R38", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Metal roofR_T24_2013_24.86", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": null, + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Metal Standing Seam - 1/16 in. CBES", + "material_2": "R_T24_2013_24.86", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Metal roofR1_R14.20", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": null, + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Metal Standing Seam - 1/16 in. CBES", + "material_2": "R1_R14.20", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Metal roofR2_R12.90", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": null, + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Metal Standing Seam - 1/16 in. CBES", + "material_2": "R2_R12.90", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Metal roofR3_R17.74", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": null, + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Metal Standing Seam - 1/16 in. CBES", + "material_2": "R3_R17.74", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Metal roofR4_R20.28", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": null, + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Metal Standing Seam - 1/16 in. CBES", + "material_2": "R4_R20.28", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Built Up Roof", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Built-up Roofing", + "material_2": "Typical Insulation", + "material_3": "Metal Surface", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Built Up Roof - Highly Reflective", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Built-up Roofing - Highly Reflective", + "material_2": "Typical Insulation", + "material_3": "Metal Surface", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical IEAD Roof", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Roof Membrane", + "material_2": "Typical Insulation", + "material_3": "Metal Roof Surface", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical IEAD Roof - Highly Reflective", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "IEAD", + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Roof Membrane - Highly Reflective", + "material_2": "Typical Insulation", + "material_3": "Metal Roof Surface", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Insulated Metal Building Roof", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Metal Roof Surface", + "material_2": "Typical Insulation", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Insulated Metal Building Roof - Highly Reflective", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Metal Roof Surface - Highly Reflective", + "material_2": "Typical Insulation", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Uninsulated Metal Building Roof", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Metal Roofing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Uninsulated Metal Building Roof - Highly Reflective", + "intended_surface_type": "ExteriorRoof", + "standards_construction_type": "Metal Building", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Metal Roofing - Highly Reflective", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Adiabatic Wall", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Adiabatic Material", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Metal framed wallsW_m1_R15", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": null, + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Stucco - 7/8 in. CBES", + "material_2": "W_m1_R15", + "material_3": "Air - Metal Wall Framing - 16 or 24 in. OC", + "material_4": "Gypsum Board - 1/2 in. CBES", + "material_5": null, + "material_6": null + }, + { + "name": "Metal framed wallsW_m2_R19", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": null, + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Stucco - 7/8 in. CBES", + "material_2": "W_m2_R19", + "material_3": "Air - Metal Wall Framing - 16 or 24 in. OC", + "material_4": "Gypsum Board - 1/2 in. CBES", + "material_5": null, + "material_6": null + }, + { + "name": "Metal framed wallsW_m3_R21", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": null, + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Stucco - 7/8 in. CBES", + "material_2": "W_m3_R21", + "material_3": "Air - Metal Wall Framing - 16 or 24 in. OC", + "material_4": "Gypsum Board - 1/2 in. CBES", + "material_5": null, + "material_6": null + }, + { + "name": "Metal framed wallsW_T24_2013_R13.99", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": null, + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Stucco - 7/8 in. CBES", + "material_2": "W_T24_2013_R13.99", + "material_3": "Air - Metal Wall Framing - 16 or 24 in. OC", + "material_4": "Gypsum Board - 1/2 in. CBES", + "material_5": null, + "material_6": null + }, + { + "name": "Metal framed wallsW1_R8.60", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": null, + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Stucco - 7/8 in. CBES", + "material_2": "W1_R8.60", + "material_3": "Air - Metal Wall Framing - 16 or 24 in. OC", + "material_4": "Gypsum Board - 1/2 in. CBES", + "material_5": null, + "material_6": null + }, + { + "name": "Metal framed wallsW2_R11.13", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": null, + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Stucco - 7/8 in. CBES", + "material_2": "W2_R11.13", + "material_3": "Air - Metal Wall Framing - 16 or 24 in. OC", + "material_4": "Gypsum Board - 1/2 in. CBES", + "material_5": null, + "material_6": null + }, + { + "name": "Metal framed wallsW3_R11.36", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": null, + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Stucco - 7/8 in. CBES", + "material_2": "W3_R11.36", + "material_3": "Air - Metal Wall Framing - 16 or 24 in. OC", + "material_4": "Gypsum Board - 1/2 in. CBES", + "material_5": null, + "material_6": null + }, + { + "name": "Metal framed wallsW4_R12.62", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": null, + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Stucco - 7/8 in. CBES", + "material_2": "W4_R12.62", + "material_3": "Air - Metal Wall Framing - 16 or 24 in. OC", + "material_4": "Gypsum Board - 1/2 in. CBES", + "material_5": null, + "material_6": null + }, + { + "name": "Typical Insulated Exterior Mass Wall", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "1IN Stucco", + "material_2": "8IN CONCRETE HW RefBldg", + "material_3": "Typical Insulation", + "material_4": "1/2IN Gypsum", + "material_5": null, + "material_6": null + }, + { + "name": "Typical Insulated Metal Building Wall", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Metal Siding", + "material_2": "Typical Insulation", + "material_3": "1/2IN Gypsum", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Insulated Steel Framed Exterior Wall", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "25mm Stucco", + "material_2": "5/8 in. Gypsum Board", + "material_3": "Typical Insulation", + "material_4": "5/8 in. Gypsum Board", + "material_5": null, + "material_6": null + }, + { + "name": "Typical Insulated Wood Framed Exterior Wall", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "WoodFramed", + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "25mm Stucco", + "material_2": "5/8 in. Gypsum Board", + "material_3": "Typical Insulation", + "material_4": "5/8 in. Gypsum Board", + "material_5": null, + "material_6": null + }, + { + "name": "Typical Uninsulated Exterior Mass Wall", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Mass", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "1IN Stucco", + "material_2": "8IN CONCRETE HW RefBldg", + "material_3": "1/2IN Gypsum", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Uninsulated Metal Building Wall", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "Metal Building", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Metal Siding", + "material_2": "1/2IN Gypsum", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Uninsulated Steel Framed Exterior Wall", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": "SteelFramed", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Wood Siding", + "material_2": "1/2IN Gypsum", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "WoodWallU110", + "intended_surface_type": "ExteriorWall", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Plywood - 5/8 in.", + "material_2": "Compliance Insulation R6.46", + "material_3": "Air - Metal Wall Framing - 16 or 24 in. OC", + "material_4": "Gypsum Board - 3/8 in.", + "material_5": null, + "material_6": null + }, + { + "name": "ASHRAE 189.1-2009 ExtWindow ClimateZone 1", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Theoretical Glass [167]", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "ASHRAE 189.1-2009 ExtWindow ClimateZone 2", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Theoretical Glass [197]", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "ASHRAE 189.1-2009 ExtWindow ClimateZone 3", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Theoretical Glass [202]", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "ASHRAE 189.1-2009 ExtWindow ClimateZone 4-5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Theoretical Glass [207]", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "ASHRAE 189.1-2009 ExtWindow ClimateZone 6", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Theoretical Glass [216]", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "ASHRAE 189.1-2009 ExtWindow ClimateZone 7-8", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Theoretical Glass [221]", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "ASHRAE 189.1-2009 ExtWindow ClimateZone alt-res 4-5", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Theoretical Glass [216]", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.11 SHGC 0.34 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.11 SHGC 0.34 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.11 SHGC 0.38 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.11 SHGC 0.38 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.12 SHGC 0.34 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.12 SHGC 0.34 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.12 SHGC 0.38 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.12 SHGC 0.38 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.13 SHGC 0.32 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.13 SHGC 0.32 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.13 SHGC 0.38 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.13 SHGC 0.38 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.14 SHGC 0.31 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.14 SHGC 0.31 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.14 SHGC 0.34 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.14 SHGC 0.34 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.14 SHGC 0.36 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.14 SHGC 0.36 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.14 SHGC 0.38 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.14 SHGC 0.38 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.15 SHGC 0.31 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.15 SHGC 0.31 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.15 SHGC 0.34 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.15 SHGC 0.34 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.17 SHGC 0.31 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.17 SHGC 0.31 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.17 SHGC 0.32 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.17 SHGC 0.32 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.17 SHGC 0.36 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.17 SHGC 0.36 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.18 SHGC 0.22 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.18 SHGC 0.22 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.18 SHGC 0.24 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.18 SHGC 0.24 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.19 SHGC 0.20 Trp LoE Film (55) Bronze 6mm/13mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "BRONZE 6MM", + "material_2": "AIR 13MM", + "material_3": "COATED POLY-55", + "material_4": "AIR 13MM", + "material_5": "CLEAR 3MM", + "material_6": null + }, + { + "name": "U 0.20 SHGC 0.19 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.20 SHGC 0.19 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.20 SHGC 0.20 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.20 SHGC 0.20 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.20 SHGC 0.21 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.20 SHGC 0.21 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.20 SHGC 0.22 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.20 SHGC 0.22 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.23 SHGC 0.31 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.23 SHGC 0.31 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.23 SHGC 0.34 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.23 SHGC 0.34 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.24 SHGC 0.11 Dbl LoE Elec Abs Colored 6mm/13mm Arg", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "ECABS-2 COLORED 6MM", + "material_2": "ARGON 13MM", + "material_3": "LoE SPEC SEL CLEAR 6MM Rev", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.24 SHGC 0.16 Dbl Elec Abs Colored 6mm/13mm Arg", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "ECABS-2 COLORED 6MM", + "material_2": "ARGON 13MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.24 SHGC 0.23 Dbl LoE Spec Sel Tint 6mm/13mm Arg", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "LoE SPEC SEL TINT 6MM", + "material_2": "ARGON 13MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.25 SHGC 0.22 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.25 SHGC 0.22 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.25 SHGC 0.24 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.25 SHGC 0.24 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.25 SHGC 0.40 Dbl LoE (e2-.1) Tint 6mm/13mm Arg", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "LoE TINT 6MM", + "material_2": "ARGON 13MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.26 SHGC 0.40 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.26 SHGC 0.40 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.29 SHGC 0.11 Dbl LoE Elec Ref Colored 6mm/13mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "ECREF-2 COLORED 6MM", + "material_2": "AIR 13MM", + "material_3": "LoE SPEC SEL CLEAR 6MM Rev", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.29 SHGC 0.17 Dbl Elec Abs Colored 6mm/13mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "ECABS-2 COLORED 6MM", + "material_2": "AIR 13MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.29 SHGC 0.22 Trp LoE Film (55) Bronze 6mm/6mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "BRONZE 6MM", + "material_2": "AIR 6MM", + "material_3": "COATED POLY-55", + "material_4": "AIR 6MM", + "material_5": "CLEAR 3MM", + "material_6": null + }, + { + "name": "U 0.29 SHGC 0.40 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.29 SHGC 0.40 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.30 SHGC 0.40 Dbl LoE (e2-.1) Tint 6mm/13mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "LoE TINT 6MM", + "material_2": "AIR 13MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.32 SHGC 0.36 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.32 SHGC 0.36 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.33 SHGC 0.11 Dbl LoE Elec Ref Colored 6mm/13mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "ECREF-2 COLORED 6MM", + "material_2": "AIR 13MM", + "material_3": "LoE SPEC SEL CLEAR 6MM Rev", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.33 SHGC 0.40 Dbl LoE (e2-.1) Tint 6mm/13mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "LoE TINT 6MM", + "material_2": "AIR 13MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.33 SHGC 0.45 Trp LoE Film (77) Clr 3mm/6mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "CLEAR 3MM", + "material_2": "AIR 6MM", + "material_3": "COATED POLY-77", + "material_4": "AIR 6MM", + "material_5": "CLEAR 3MM", + "material_6": null + }, + { + "name": "U 0.34 SHGC 0.38 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.34 SHGC 0.38 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.34 SHGC 0.40 Dbl LoE (e2-.1) Tint 6mm/13mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "LoE TINT 6MM", + "material_2": "AIR 13MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.34 SHGC 0.45 Dbl LoE (e2-.2) Clr 6mm/13mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "PYR B CLEAR 6MM", + "material_2": "AIR 13MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.35 SHGC 0.22 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.35 SHGC 0.22 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.35 SHGC 0.24 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.35 SHGC 0.24 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.35 SHGC 0.26 Dbl Ref-C-M Clr 6mm/13mm Arg", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF C CLEAR MID 6MM", + "material_2": "ARGON 13MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.35 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/13mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "LoE TINT 6MM", + "material_2": "AIR 13MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.36 SHGC 0.35 Dbl LoE Spec Sel Tint 6mm/6mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "LoE SPEC SEL TINT 6MM", + "material_2": "AIR 6MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.36 SHGC 0.36 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.36 SHGC 0.36 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.36 SHGC 0.38 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.36 SHGC 0.38 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.38 SHGC 0.26 Dbl Ref B-H Tint 6mm/13mm Arg", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF B TINT HI 6MM", + "material_2": "ARGON 13MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.38 SHGC 0.30 Dbl Ref-B-H Clr 6mm/13mm Arg", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF B CLEAR HI 6MM", + "material_2": "ARGON 13MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.39 SHGC 0.32", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Theoretical Glass 347", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.39 SHGC 0.38", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Theoretical Glass 297", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.40 SHGC 0.43 Dbl LoE Spec Sel Clr 3mm/6mm/6mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "LoE SPEC SEL CLEAR 3MM", + "material_2": "AIR 6MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.40 SHGC 0.45", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "ECABS-2 BLEACHED 6MM", + "material_2": "AIR 6MM", + "material_3": "LoE SPEC SEL CLEAR 6MM Rev", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.42 SHGC 0.25 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.42 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.42 SHGC 0.34 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.42 SHGC 0.34 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.42 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/6mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "LoE TINT 6MM", + "material_2": "AIR 6MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.42 SHGC 0.40 Dbl LoE (e2-.1) Tint 6mm/6mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "LoE TINT 6MM", + "material_2": "AIR 6MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.42 SHGC 0.45 Dbl Ref-D Clr 6mm/13mm Arg", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF D CLEAR 6MM", + "material_2": "ARGON 13MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.43 SHGC 0.26 Dbl Ref-B-H Clr 6mm/13mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF B CLEAR HI 6MM", + "material_2": "AIR 13MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.43 SHGC 0.29 Dbl LoE Spec Sel Tint 6mm/6mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "LoE SPEC SEL TINT 6MM", + "material_2": "AIR 6MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.44 SHGC 0.20 Dbl Ref-B-H Tint 6mm/13mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF B TINT HI 6MM", + "material_2": "AIR 13MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.44 SHGC 0.26 Dbl Ref-B-H Clr 6mm/13mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF B CLEAR HI 6MM", + "material_2": "AIR 13MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.45 SHGC 0.25 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.45 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.45 SHGC 0.31 Dbl Ref-B-H Clr 6mm/13mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF B CLEAR HI 6MM", + "material_2": "AIR 13MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.45 SHGC 0.33 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.45 SHGC 0.33 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.46 SHGC 0.45 Dbl Grey 6mm/13mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "GREY 6MM", + "material_2": "AIR 13MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.47 SHGC 0.33 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.47 SHGC 0.33 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.48 SHGC 0.19 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.48 SHGC 0.19 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.48 SHGC 0.21 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.48 SHGC 0.21 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.48 SHGC 0.20 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.48 SHGC 0.20 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.48 SHGC 0.22 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.48 SHGC 0.22 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.48 SHGC 0.40 Dbl Ref-D Clr 6mm/13mm", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF D CLEAR 6MM", + "material_2": "AIR 13MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.50 SHGC 0.22 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.50 SHGC 0.22 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.50 SHGC 0.23 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.50 SHGC 0.23 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.52 SHGC 0.22 Dbl Ref-B-L Clr 6mm/6mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF B CLEAR LO 6MM", + "material_2": "AIR 6MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.52 SHGC 0.39 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.52 SHGC 0.39 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.52 SHGC 0.40 Dbl Ref-D Clr 6mm/13mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF D CLEAR 6MM", + "material_2": "AIR 13MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.52 SHGC 0.49 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.52 SHGC 0.49 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.52 SHGC 0.615 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.52 SHGC 0.615 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.54 SHGC 0.13 Dbl Ref-A-L Clr 6mm/13mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF A CLEAR LO 6MM", + "material_2": "AIR 13MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.54 SHGC 0.18 Dbl Ref-A-M Tint 6mm/6mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF A TINT MID 6MM", + "material_2": "AIR 6MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.54 SHGC 0.23 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.54 SHGC 0.23 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.54 SHGC 0.27 Dbl Ref-C-H Clr 6mm/6mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF C CLEAR HI 6MM", + "material_2": "AIR 6MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.55 SHGC 0.25", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Glass_2175_LayerAvg", + "material_2": "Gap_1_W_0_0032", + "material_3": "Glass_2022F_LayerAvg", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.55 SHGC 0.31 Dbl Ref-D Tint 6mm/6mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF D TINT 6MM", + "material_2": "AIR 6MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.56 SHGC 0.35 Dbl Ref-D Tint 6mm/6mm", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF D TINT 6MM", + "material_2": "AIR 6MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.56 SHGC 0.76 Dbl Clr 3mm/6mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "CLEAR 3MM", + "material_2": "AIR 6MM", + "material_3": "CLEAR 3MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.57 SHGC 0.25 Dbl Ref-C-H Clr 6mm/6mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF C CLEAR HI 6MM", + "material_2": "AIR 6MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF D CLEAR 6MM", + "material_2": "AIR 6MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "BLUE 6MM", + "material_2": "AIR 6MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.59 SHGC 0.36 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.59 SHGC 0.36 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.59 SHGC 0.39 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.59 SHGC 0.39 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.60 SHGC 0.23 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.60 SHGC 0.23 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.62 SHGC 0.20 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.62 SHGC 0.20 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.62 SHGC 0.21 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.62 SHGC 0.21 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.62 SHGC 0.25 Dbl Ref-C-H Clr 6mm/6mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF C CLEAR HI 6MM", + "material_2": "AIR 6MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.62 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF D CLEAR 6MM", + "material_2": "AIR 6MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.62 SHGC 0.41 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.62 SHGC 0.41 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.62 SHGC 0.49 Dbl Blue 6mm/6mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "BLUE 6MM", + "material_2": "AIR 6MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.65 SHGC 0.25 Dbl Ref-C-H Clr 6mm/6mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF C CLEAR HI 6MM", + "material_2": "AIR 6MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.67 SHGC 0.77 Sgl LoE (e2-.2) Clr 3mm", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "PYR B CLEAR 3MM", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.71 SHGC 0.25 Dbl Ref-C-H Clr 6mm/6mm Air", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF C CLEAR HI 6MM", + "material_2": "AIR 6MM", + "material_3": "CLEAR 6MM", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.72 SHGC 0.25 Sgl Ref-B-M Tint 6mm", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF B TINT MID 6MM", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.72 SHGC 0.25 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.72 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.72 SHGC 0.36 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.72 SHGC 0.36 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.72 SHGC 0.39 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.72 SHGC 0.39 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.75 SHGC 0.72 Sgl LoE (e2-.2) Clr 6mm", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "PYR B CLEAR 6MM", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.88 SHGC 0.16 Sgl Ref-A-L Clr 6mm", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF A CLEAR LO 6MM", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.88 SHGC 0.27 Sgl Elec Ref Colored 6mm", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "ECREF-1 COLORED 6MM", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.98 SHGC 0.45 Sgl Ref-B-H Clr 6mm", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF B CLEAR HI 6MM", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.98 SHGC 0.68 Sgl Ref-B-H Clr 6mm", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF B CLEAR HI 6MM", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.17 SHGC 0.39 Sgl Ref-B-H Clr 6mm", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF B CLEAR HI 6MM", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.17 SHGC 0.49 Sgl Ref-D Clr 6mm", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF D CLEAR 6MM", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.17 SHGC 0.68 Sgl Green 3mm", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "GREEN 3MM", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "ECREF-1 COLORED 6MM", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.22 SHGC 0.25 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.22 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.22 SHGC 0.34 Sgl Ref-C-H Clr 6mm", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF C CLEAR HI 6MM", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.22 SHGC 0.39 Sgl Ref-B-H Clr 6mm", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF B CLEAR HI 6MM", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.22 SHGC 0.54 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.22 SHGC 0.54 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.22 SHGC 0.61 Sgl Green 6mm", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "GREEN 6MM", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.98 SHGC 0.36 Sgl Ref-B-H Clr 6mm", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "REF B CLEAR HI 6MM", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.98 SHGC 0.61 Sgl Green 6mm", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Metal framing (all other)", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "GREEN 6MM", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U0.47_SHGC_0.49_SimpleGlazing_Window_05", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U0.47_SHGC_0.49_SimpleGlazing_Window_05", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U0.47_SHGC0.46_SimpleGlazing_Window_07", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U0.47_SHGC0.46_SimpleGlazing_Window_07", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U0.47_SHGC0.47_SimpleGlazing_Window_06", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U0.47_SHGC0.47_SimpleGlazing_Window_06", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U0.47_SHGC0.47_SimpleGlazing_Window_11", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U0.47_SHGC0.47_SimpleGlazing_Window_11", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U0.47_SHGC0.5_SimpleGlazing_Window_03", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U0.47_SHGC0.5_SimpleGlazing_Window_03", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U0.77_SHGC_0.77_SimpleGlazing_Window_02", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U0.77_SHGC_0.77_SimpleGlazing_Window_02", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U0.77_SHGC0.5_SimpleGlazing_Window_09", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U0.77_SHGC0.5_SimpleGlazing_Window_09", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U0.77_SHGC0.61_SimpleGlazing_Window_08", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U0.77_SHGC0.61_SimpleGlazing_Window_08", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U0.77_SHGC0.62_SimpleGlazing_Window_04", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U0.77_SHGC0.62_SimpleGlazing_Window_04", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U1.23_SHGC0.5_SimpleGlazing_Window_12", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U1.23_SHGC0.5_SimpleGlazing_Window_12", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U1.23_SHGC0.82_SimpleGlazing_Window_01", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U1.23_SHGC0.82_SimpleGlazing_Window_01", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U1.23_SHGC0.82_SimpleGlazing_Window_10", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U1.23_SHGC0.82_SimpleGlazing_Window_10", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Adiabatic GroundContactFloor", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Mass", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Adiabatic Material", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "ext-slab", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Mass", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "6 in. Normalweight Concrete Floor", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "ext-slab-mass", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Mass", + "insulation_layer": "CP02 CARPET PAD", + "skylight_framing": null, + "material_1": "HW CONCRETE", + "material_2": "CP02 CARPET PAD", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "ext-slab-metal-building", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Metal Building", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "HW CONCRETE 8 in", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "ext-slab-steel-frame", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "SteelFramed", + "insulation_layer": "CP02 CARPET PAD", + "skylight_framing": null, + "material_1": "HW CONCRETE 8 in", + "material_2": "CP02 CARPET PAD", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Ground FloorGround_Floor_R11_T2013", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Ground_Floor_R11_T2013", + "material_2": "Plywood - 5/8 in. CBES", + "material_3": "Carpet - 3/4 in. CBES", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Ground FloorGround_Floor_R17_T2013", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Ground_Floor_R17_T2013", + "material_2": "Plywood - 5/8 in. CBES", + "material_3": "Carpet - 3/4 in. CBES", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Ground FloorGround_Floor_R22_T2013", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Ground_Floor_R22_T2013", + "material_2": "Plywood - 5/8 in. CBES", + "material_3": "Carpet - 3/4 in. CBES", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Smallhotel 2010 Slab Floor", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Mass", + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "8 in. Normalweight Concrete Floor", + "material_2": "CP02 CARPET PAD", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Carpeted 6in Slab Floor", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Mass", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "6 in. Normalweight Concrete Floor", + "material_2": "Typical Carpet Pad", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Carpeted 8in Slab Floor", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Mass", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "8 in. Normalweight Concrete Floor", + "material_2": "Typical Carpet Pad", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Insulated 6in Slab Floor", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Mass", + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Typical Insulation", + "material_2": "6 in. Normalweight Concrete Floor", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Insulated 8in Slab Floor", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Mass", + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Typical Insulation", + "material_2": "8 in. Normalweight Concrete Floor", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Insulated Carpeted 6in Slab Floor", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Mass", + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Typical Insulation", + "material_2": "6 in. Normalweight Concrete Floor", + "material_3": "Typical Carpet Pad", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Insulated Carpeted 8in Slab Floor", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Mass", + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Typical Insulation", + "material_2": "8 in. Normalweight Concrete Floor", + "material_3": "Typical Carpet Pad", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Uncarpeted 6in Slab Floor", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Mass", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "6 in. Normalweight Concrete Floor", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Uninsulated 6in Slab Floor", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Mass", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "6 in. Normalweight Concrete Floor", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Uninsulated 8in Slab Floor", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Mass", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "8 in. Normalweight Concrete Floor", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Uninsulated Carpeted 8in Slab Floor", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Mass", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "8 in. Concrete Block Basement Wall", + "material_2": "Typical Carpet Pad", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Unisulated Carpeted 6in Slab Floor", + "intended_surface_type": "GroundContactFloor", + "standards_construction_type": "Mass", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "6 in. Normalweight Concrete Floor", + "material_2": "Typical Carpet Pad", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Insulated Basement Mass Wall", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "Typical Insulation", + "material_2": "8 in. Concrete Block Basement Wall", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Uninsulated Basement Mass Wall", + "intended_surface_type": "GroundContactWall", + "standards_construction_type": "Mass", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "8 in. Concrete Block Basement Wall", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "ceiling_Metal roof", + "intended_surface_type": "InteriorCeiling", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Metal Standing Seam - 1/16 in.", + "material_2": "ceiling_2_Insulation", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "int_slab_ceiling_smallhotel", + "intended_surface_type": "InteriorCeiling", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "CP02 CARPET PAD", + "material_2": "4 in. Normalweight Concrete Floor", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "LargeHotel Interior Ceiling", + "intended_surface_type": "InteriorCeiling", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "CP02 CARPET PAD", + "material_2": "100mm Normalweight concrete floor", + "material_3": "Nonres_Floor_Insulation", + "material_4": "G01 13mm gypsum board", + "material_5": null, + "material_6": null + }, + { + "name": "NACM_Drop Ceiling", + "intended_surface_type": "InteriorCeiling", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Acoustic Ceiling", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Plenum Acoustical Tile", + "intended_surface_type": "InteriorCeiling", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Acoustic Tile - 1/2 in.", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Interior Ceiling", + "intended_surface_type": "InteriorCeiling", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "CP02 CARPET PAD", + "material_2": "100mm Normalweight concrete floor", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Interior Door", + "intended_surface_type": "InteriorDoor", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "G05 25mm wood", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "int_slab_floor_smallhotel", + "intended_surface_type": "InteriorFloor", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "4 in. Normalweight Concrete Floor", + "material_2": "CP02 CARPET PAD", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "LargeHotel Interior Floor", + "intended_surface_type": "InteriorFloor", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "G01 13mm gypsum board", + "material_2": "Nonres_Floor_Insulation", + "material_3": "100mm Normalweight concrete floor", + "material_4": "CP02 CARPET PAD", + "material_5": null, + "material_6": null + }, + { + "name": "NACM_Interior Floor", + "intended_surface_type": "InteriorFloor", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "NACM_Carpet 3/4in", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Interior Floor", + "intended_surface_type": "InteriorFloor", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "100mm Normalweight concrete floor", + "material_2": "CP02 CARPET PAD", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Interior Slab Floor", + "intended_surface_type": "InteriorFloor", + "standards_construction_type": "Mass", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "4 in. Normalweight Concrete Floor", + "material_2": "Typical Carpet Pad", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Interior Partition", + "intended_surface_type": "InteriorPartition", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "G05 25mm wood", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Uninsulated Steel Stud Wall", + "intended_surface_type": "InteriorPartition", + "standards_construction_type": "SteelFramed", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Metal Framed Wall - 24inOC - 2x4 - R0 ins.", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "int_wall_smallhotel", + "intended_surface_type": "InteriorWall", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "1/2 in. Gypsum Board", + "material_2": "1/2 in. Gypsum Board", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "LargeHotel Interior Wall", + "intended_surface_type": "InteriorWall", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "G01 13mm gypsum board", + "material_2": "G01 13mm gypsum board", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "NACM_Interior Wall", + "intended_surface_type": "InteriorWall", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "NACM_Gypsum Board 5/8in", + "material_2": "NACM_Gypsum Board 5/8in", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Insulated Interior Wall", + "intended_surface_type": "InteriorWall", + "standards_construction_type": "WoodFramed", + "insulation_layer": "Typical Insulation", + "skylight_framing": null, + "material_1": "25mm Stucco", + "material_2": "5/8 in. Gypsum Board", + "material_3": "Typical Insulation", + "material_4": "Steel Frame/Cavity", + "material_5": "5/8 in. Gypsum Board", + "material_6": null + }, + { + "name": "Typical Interior Wall", + "intended_surface_type": "InteriorWall", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "G01 13mm gypsum board", + "material_2": "G01 13mm gypsum board", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Uninsulated Interior Wall", + "intended_surface_type": "InteriorWall", + "standards_construction_type": "WoodFramed", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "1/2 in. Gypsum Board", + "material_2": "1/2 in. Gypsum Board", + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Typical Interior Window", + "intended_surface_type": "InteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "CLEAR 3MM", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.58 SHGC 0.19 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.58 SHGC 0.19 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.58 SHGC 0.36 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.58 SHGC 0.36 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.98 SHGC 0.61 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Glass with Curb", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.98 SHGC 0.61 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Window_U_0.50_SHGC_0.40_Skylight_Frame_Width_0.000_in", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": "Skylight_Frame_Width_0.000_in", + "material_1": "Glass_2052_LayerAvg", + "material_2": "Gap_1_W_0_0038", + "material_3": "Glass_2027F_LayerAvg", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Window_U_0.50_SHGC_0.40_Skylight_Frame_Width_0.334_in", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": "Skylight_Frame_Width_0.334_in", + "material_1": "Glass_2052_LayerAvg", + "material_2": "Gap_1_W_0_0038", + "material_3": "Glass_2027F_LayerAvg", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Window_U_0.50_SHGC_0.40_Skylight_Frame_Width_0.430_in", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": "Skylight_Frame_Width_0.430_in", + "material_1": "Glass_2052_LayerAvg", + "material_2": "Gap_1_W_0_0038", + "material_3": "Glass_2027F_LayerAvg", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Window_U_0.55_SHGC_0.35_Skylight_Frame_Width_0.709_in", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": "Skylight_Frame_Width_0.709_in", + "material_1": "Glass_2052_LayerAvg", + "material_2": "Gap_1_W_0_0038", + "material_3": "Glass_2027F_LayerAvg", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Window_U_0.65_SHGC_0.35_Skylight_Frame_Width_2.339_in", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": "Skylight_Frame_Width_2.339_in", + "material_1": "Glass_2052_LayerAvg", + "material_2": "Gap_1_W_0_0024", + "material_3": "Glass_2027F_LayerAvg", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "Window_U_0.75_SHGC_0.35_Skylight_Frame_Width_2.339_in", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": "Skylight_Frame_Width_2.339_in", + "material_1": "Glass_2052_LayerAvg", + "material_2": "Gap_1_W_0_0018", + "material_3": "Glass_2027F_LayerAvg", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.60 SHGC 0.25 Dbl 2.5mm air", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "Glass_2175_LayerAvg", + "material_2": "Gap_1_W_0_0025", + "material_3": "Glass_2022F_LayerAvg", + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.61 SHGC 0.77 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.61 SHGC 0.77 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.65 SHGC 0.35 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.65 SHGC 0.35 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.69 SHGC 0.19 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.69 SHGC 0.19 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.69 SHGC 0.36 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.69 SHGC 0.36 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.69 SHGC 0.39 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.69 SHGC 0.39 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.69 SHGC 0.49 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.69 SHGC 0.49 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.69 SHGC 0.64 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.69 SHGC 0.64 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.69 SHGC 0.68 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.69 SHGC 0.68 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.74 SHGC 0.55 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.74 SHGC 0.55 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.74 SHGC 0.65 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.74 SHGC 0.65 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.75 SHGC 0.35 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.75 SHGC 0.35 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.81 SHGC 0.65 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.81 SHGC 0.65 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.85 SHGC 0.65 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.85 SHGC 0.65 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.87 SHGC 0.58 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.87 SHGC 0.58 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.87 SHGC 0.71 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.87 SHGC 0.71 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.87 SHGC 0.77 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.87 SHGC 0.77 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.98 SHGC 0.19 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.98 SHGC 0.19 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.98 SHGC 0.36 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.98 SHGC 0.36 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.10 SHGC 0.62 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.10 SHGC 0.62 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.10 SHGC 0.77 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.10 SHGC 0.77 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.15 SHGC 0.77 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.15 SHGC 0.77 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.17 SHGC 0.19 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.17 SHGC 0.19 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.17 SHGC 0.36 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.17 SHGC 0.36 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.17 SHGC 0.39 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.17 SHGC 0.39 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.17 SHGC 0.49 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.17 SHGC 0.49 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.17 SHGC 0.64 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.17 SHGC 0.64 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.17 SHGC 0.68 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.17 SHGC 0.68 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.30 SHGC 0.27 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.30 SHGC 0.27 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.30 SHGC 0.34 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.30 SHGC 0.34 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.30 SHGC 0.62 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.30 SHGC 0.62 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.30 SHGC 0.65 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.30 SHGC 0.65 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.36 SHGC 0.19 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.36 SHGC 0.19 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.36 SHGC 0.36 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.36 SHGC 0.36 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.36 SHGC 0.39 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.36 SHGC 0.39 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.36 SHGC 0.61 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.36 SHGC 0.61 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.70 SHGC 0.36 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.70 SHGC 0.36 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.80 SHGC 0.36 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.80 SHGC 0.36 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.90 SHGC 0.27 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.90 SHGC 0.27 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.90 SHGC 0.34 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.90 SHGC 0.34 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.90 SHGC 0.39 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.90 SHGC 0.39 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.90 SHGC 0.65 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.90 SHGC 0.65 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.98 SHGC 0.16 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.98 SHGC 0.16 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.98 SHGC 0.19 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.98 SHGC 0.19 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.98 SHGC 0.36 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.98 SHGC 0.36 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.98 SHGC 0.39 Simple Glazing Skylight", + "intended_surface_type": null, + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.98 SHGC 0.39 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.49 SHGC 0.22 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.49 SHGC 0.22 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.57 SHGC 0.25 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.57 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.53 SHGC 0.25 Simple Glazing Window Weighted", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.53 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.48 SHGC 0.25 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.48 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.38 SHGC 0.36 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.38 SHGC 0.36 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.38 SHGC 0.38 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.38 SHGC 0.38 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.36 SHGC 0.4 Simple Glazing Window Weighted", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.36 SHGC 0.4 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.33 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.33 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.29 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.29 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.5 SHGC 0.22 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.5 SHGC 0.22 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.54 SHGC 0.25 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.54 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.49 SHGC 0.25 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.49 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.45 SHGC 0.25 Simple Glazing Window Weighted", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.45 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.19 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.19 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.73 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.73 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.62 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.62 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.51 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.51 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.38 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.38 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.53 SHGC 0.22 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.53 SHGC 0.22 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.53 SHGC 0.23 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.53 SHGC 0.23 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.38 SHGC 0.35 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.38 SHGC 0.35 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.38 SHGC 0.37 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.38 SHGC 0.37 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.36 SHGC 0.37 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.36 SHGC 0.37 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.31 SHGC 0.39 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.31 SHGC 0.39 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.28 SHGC 0.39 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.28 SHGC 0.39 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.51 SHGC 0.22 Simple Glazing Window Weighted", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.51 SHGC 0.22 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.51 SHGC 0.23 Simple Glazing Window Weighted", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.51 SHGC 0.23 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.46 SHGC 0.25 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.46 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.43 SHGC 0.25 Simple Glazing Window Weighted", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.43 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.36 SHGC 0.36 Simple Glazing Window Weighted", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.36 SHGC 0.36 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.36 SHGC 0.38 Simple Glazing Window Weighted", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.36 SHGC 0.38 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.34 SHGC 0.38 Simple Glazing Window Weighted", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.34 SHGC 0.38 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.29 SHGC 0.4 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.29 SHGC 0.4 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.26 SHGC 0.4 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.26 SHGC 0.4 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.37 SHGC 0.36 Simple Glazing Window Weighted", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.37 SHGC 0.36 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.37 SHGC 0.38 Simple Glazing Window Weighted", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.37 SHGC 0.38 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.35 SHGC 0.38 Simple Glazing Window Weighted", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.35 SHGC 0.38 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.3 SHGC 0.4 Simple Glazing Window Weighted", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.3 SHGC 0.4 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.27 SHGC 0.4 Simple Glazing Window Weighted", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.27 SHGC 0.4 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.5 SHGC 0.23 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.5 SHGC 0.23 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.42 SHGC 0.25 Simple Glazing Window Weighted", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.42 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.47 SHGC 0.25 Simple Glazing Window Weighted", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.47 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.2 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.2 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.5 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.5 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.39 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.39 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.36 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.36 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.75 SHGC 0.35 Simple Glazing Window", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.75 SHGC 0.35 Simple Glazing Window", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.65 SHGC 0.35 Simple Glazing Window", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.65 SHGC 0.35 Simple Glazing Window", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.55 SHGC 0.35 Simple Glazing Window", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.55 SHGC 0.35 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.5 SHGC 0.4 Simple Glazing Window", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.5 SHGC 0.4 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.5 SHGC 0.55 Simple Glazing Window", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.5 SHGC 0.55 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.41 SHGC 0.55 Simple Glazing Window", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.41 SHGC 0.55 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.8 SHGC 0.55 Simple Glazing Window", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.8 SHGC 0.55 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.7 SHGC 0.55 Simple Glazing Window", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.7 SHGC 0.55 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.15 SHGC 0.55 Simple Glazing Window", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.15 SHGC 0.55 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.98 SHGC 0.55 Simple Glazing Window", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.98 SHGC 0.55 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.85 SHGC 0.55 Simple Glazing Window", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.85 SHGC 0.55 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.7 SHGC 0.3 Simple Glazing Window", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.7 SHGC 0.3 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.65 SHGC 0.3 Simple Glazing Window", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.65 SHGC 0.3 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.55 SHGC 0.3 Simple Glazing Window", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.55 SHGC 0.3 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.47 SHGC 0.4 Simple Glazing Window", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.47 SHGC 0.4 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.44 SHGC 0.55 Simple Glazing Window", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.44 SHGC 0.55 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.9 SHGC 0.55 Simple Glazing Window", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.9 SHGC 0.55 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.75 SHGC 0.55 Simple Glazing Window", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.75 SHGC 0.55 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.37 SHGC 0.25 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.37 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.83 SHGC 0.25 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.83 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.77 SHGC 0.25 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.77 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.93 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.93 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.83 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.83 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.65 SHGC 0.55 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.65 SHGC 0.55 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.8 SHGC 0.77 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.8 SHGC 0.77 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.65 SHGC 0.77 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.65 SHGC 0.77 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.8 SHGC 0.55 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.8 SHGC 0.55 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.65 SHGC 0.68 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.65 SHGC 0.68 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.8 SHGC 0.64 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.8 SHGC 0.64 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.33 SHGC 0.25 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.33 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.68 SHGC 0.25 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.68 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.87 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.87 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.77 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.77 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.55 SHGC 0.64 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.55 SHGC 0.64 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.55 SHGC 0.55 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.55 SHGC 0.55 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.7 SHGC 0.55 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.7 SHGC 0.55 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.31 SHGC 0.36 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.31 SHGC 0.36 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.68 SHGC 0.36 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.68 SHGC 0.36 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.5 SHGC 0.55 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.5 SHGC 0.55 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.15 SHGC 0.55 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.15 SHGC 0.55 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.31 SHGC 0.38 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.31 SHGC 0.38 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.68 SHGC 0.38 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.68 SHGC 0.38 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.45 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.45 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.5 SHGC 0.36 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.5 SHGC 0.36 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.5 SHGC 0.19 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.5 SHGC 0.19 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.98 SHGC 0.55 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.98 SHGC 0.55 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.5 SHGC 0.34 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.5 SHGC 0.34 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.98 SHGC 0.27 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.98 SHGC 0.27 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.68 SHGC 0.4 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.68 SHGC 0.4 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.85 SHGC 0.55 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.85 SHGC 0.55 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.85 SHGC 0.19 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.85 SHGC 0.19 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.85 SHGC 0.39 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.85 SHGC 0.39 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.28 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.28 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.68 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.68 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.32 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.32 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.5 SHGC 0.27 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.5 SHGC 0.27 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.25 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.25 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.5 SHGC 0.39 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.5 SHGC 0.39 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.5 SHGC 0.65 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.5 SHGC 0.65 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.85 SHGC 0.27 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.85 SHGC 0.27 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.5 SHGC 0.25 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.5 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.1 SHGC 0.25 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.1 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.1 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.1 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.75 SHGC 0.55 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.75 SHGC 0.55 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.75 SHGC 0.49 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.75 SHGC 0.49 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.8 SHGC 0.49 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.8 SHGC 0.49 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.75 SHGC 0.39 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.75 SHGC 0.39 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.75 SHGC 0.68 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.75 SHGC 0.68 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.75 SHGC 0.64 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.75 SHGC 0.64 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.77 SHGC 0.23 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.77 SHGC 0.23 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.68 SHGC 0.23 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.68 SHGC 0.23 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.63 SHGC 0.33 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.63 SHGC 0.33 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.63 SHGC 0.34 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.63 SHGC 0.34 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.63 SHGC 0.36 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.63 SHGC 0.36 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.63 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": "Weighted", + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.63 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.55 SHGC 0.35 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.55 SHGC 0.35 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.5 SHGC 0.4 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.5 SHGC 0.4 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.41 SHGC 0.55 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.41 SHGC 0.55 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.6 SHGC 0.23 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.6 SHGC 0.23 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.65 SHGC 0.3 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.65 SHGC 0.3 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.55 SHGC 0.3 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.55 SHGC 0.3 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.47 SHGC 0.4 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.47 SHGC 0.4 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.44 SHGC 0.55 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.44 SHGC 0.55 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.83 SHGC 0.21 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.83 SHGC 0.21 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.7 SHGC 0.3 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.7 SHGC 0.3 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.32 SHGC 0.22 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.32 SHGC 0.22 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.83 SHGC 0.22 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.83 SHGC 0.22 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.83 SHGC 0.2 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.83 SHGC 0.2 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.62 SHGC 0.2 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.62 SHGC 0.2 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.22 SHGC 0.19 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.22 SHGC 0.19 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.22 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.22 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.22 SHGC 0.17 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.22 SHGC 0.17 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.22 SHGC 0.39 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.22 SHGC 0.39 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.98 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.98 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.98 SHGC 0.45 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.98 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.57 SHGC 0.39 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.57 SHGC 0.39 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.46 SHGC 0.19 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.46 SHGC 0.19 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.98 SHGC 0.34 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.98 SHGC 0.34 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.22 SHGC 0.61 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.22 SHGC 0.61 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.22 SHGC 0.34 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.22 SHGC 0.34 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.57 SHGC 0.49 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.57 SHGC 0.49 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.46 SHGC 0.26 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.46 SHGC 0.26 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.98 SHGC 0.45 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.98 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.98 SHGC 0.65 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.98 SHGC 0.65 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.58 SHGC 0.61 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.58 SHGC 0.61 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.46 SHGC 0.36 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.46 SHGC 0.36 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.46 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.46 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.35 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.35 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.98 SHGC 0.62 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.98 SHGC 0.62 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.58 SHGC 0.45 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.58 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.75 SHGC 0.25 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.75 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.7 SHGC 0.25 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.7 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.98 SHGC 0.49 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.98 SHGC 0.49 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.65 SHGC 0.25 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.65 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.6 SHGC 0.25 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.6 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.9 SHGC 0.25 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.9 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.98 SHGC 0.71 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.98 SHGC 0.71 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.4 SHGC 0.4 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.4 SHGC 0.4 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.55 SHGC 0.4 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.55 SHGC 0.4 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.85 SHGC 0.4 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.85 SHGC 0.4 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.35 SHGC 0.4 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.35 SHGC 0.4 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.45 SHGC 0.4 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.45 SHGC 0.4 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.8 SHGC 0.4 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.8 SHGC 0.4 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.65 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.65 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.6 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.6 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.9 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.9 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.4 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.4 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.8 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.8 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.2 SHGC 0.25 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.2 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.98 SHGC 0.27 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.98 SHGC 0.27 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 1.17 SHGC 0.45 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 1.17 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.98 SHGC 0.49 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.98 SHGC 0.49 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.98 SHGC 0.46 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.98 SHGC 0.46 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.58 SHGC 0.65 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.58 SHGC 0.65 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.58 SHGC 0.55 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.58 SHGC 0.55 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.4 SHGC 0.25 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.4 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.65 SHGC 0.45 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.65 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.35 SHGC 0.25 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.35 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.55 SHGC 0.45 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.55 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.42 SHGC 0.4 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.42 SHGC 0.4 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.77 SHGC 0.4 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.77 SHGC 0.4 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.81 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.81 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.5 SHGC 0.45 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.5 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.32 SHGC 0.4 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.32 SHGC 0.4 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.7 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.7 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.59 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.59 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.44 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.44 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.93 SHGC 0.25 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.93 SHGC 0.25 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.75 SHGC 0.45 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.75 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.3 SHGC 0.4 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.3 SHGC 0.4 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.36 SHGC 0.4 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.36 SHGC 0.4 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.9 SHGC 0.55 Simple Glazing Skylight", + "intended_surface_type": "Skylight", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.9 SHGC 0.55 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + }, + { + "name": "U 0.48 SHGC 0.45 Simple Glazing Window", + "intended_surface_type": "ExteriorWindow", + "standards_construction_type": null, + "insulation_layer": null, + "skylight_framing": null, + "material_1": "U 0.48 SHGC 0.45 Simple Glazing", + "material_2": null, + "material_3": null, + "material_4": null, + "material_5": null, + "material_6": null + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.json b/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.json new file mode 100644 index 0000000000..19c940c013 --- /dev/null +++ b/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.json @@ -0,0 +1,464 @@ +[ + { + "support_electric_equipment_space_type_name_tags": "corridor - all other" + }, + { + "support_electric_equipment_space_type_name_tags": "dining - all other" + }, + { + "support_electric_equipment_space_type_name_tags": "electrical/mechanical" + }, + { + "support_electric_equipment_space_type_name_tags": "kitchen" + }, + { + "support_electric_equipment_space_type_name_tags": "laboratory" + }, + { + "support_electric_equipment_space_type_name_tags": "lobby - all other" + }, + { + "support_electric_equipment_space_type_name_tags": "locker room" + }, + { + "support_electric_equipment_space_type_name_tags": "lounge/breakroom - all other" + }, + { + "support_electric_equipment_space_type_name_tags": "office - enclosed <= 250 sf" + }, + { + "support_electric_equipment_space_type_name_tags": "office - enclosed > 250 sf" + }, + { + "support_electric_equipment_space_type_name_tags": "office - open" + }, + { + "support_electric_equipment_space_type_name_tags": "restroom - all other" + }, + { + "support_electric_equipment_space_type_name_tags": "stairwell" + }, + { + "support_electric_equipment_space_type_name_tags": "storage < 50 sf - all other" + }, + { + "support_electric_equipment_space_type_name_tags": "storage 50 to 1000 sf - all other" + }, + { + "support_electric_equipment_space_type_name_tags": "vehicular maintenance" + }, + { + "support_electric_equipment_space_type_name_tags": "atrium - first three floors" + }, + { + "support_electric_equipment_space_type_name_tags": "audience seating - convention center" + }, + { + "support_electric_equipment_space_type_name_tags": "classroom/lecture/training - all other" + }, + { + "support_electric_equipment_space_type_name_tags": "conference/meeting/multipurpose" + }, + { + "support_electric_equipment_space_type_name_tags": "exhibit - convention center" + }, + { + "support_electric_equipment_space_type_name_tags": "gymnasium exercise area" + }, + { + "support_electric_equipment_space_type_name_tags": "gymnasium playing area" + }, + { + "support_electric_equipment_space_type_name_tags": "laundry/washing" + }, + { + "support_electric_equipment_space_type_name_tags": "lobby - elevator" + }, + { + "support_electric_equipment_space_type_name_tags": "nurses station" + }, + { + "support_electric_equipment_space_type_name_tags": "post office - sorting area" + }, + { + "support_electric_equipment_space_type_name_tags": "sports arena playing area, class IV" + }, + { + "support_electric_equipment_space_type_name_tags": "audience seating - all other" + }, + { + "support_electric_equipment_space_type_name_tags": "confinement cells" + }, + { + "support_electric_equipment_space_type_name_tags": "judges chambers" + }, + { + "support_electric_equipment_space_type_name_tags": "library - stacks" + }, + { + "support_electric_equipment_space_type_name_tags": "storage - inactive" + }, + { + "support_electric_equipment_space_type_name_tags": "dining - bar/lounge/leisure" + }, + { + "support_electric_equipment_space_type_name_tags": "dining - cafeteria/fast food" + }, + { + "support_electric_equipment_space_type_name_tags": "dining - family" + }, + { + "support_electric_equipment_space_type_name_tags": "computer room" + }, + { + "support_electric_equipment_space_type_name_tags": "dormitory - living quarters" + }, + { + "support_electric_equipment_space_type_name_tags": "audience seating - exercise center" + }, + { + "support_electric_equipment_space_type_name_tags": "exam/treatment" + }, + { + "support_electric_equipment_space_type_name_tags": "library - reading" + }, + { + "support_electric_equipment_space_type_name_tags": "emergency vehicle garage" + }, + { + "support_electric_equipment_space_type_name_tags": "firestation - sleeping quarters" + }, + { + "support_electric_equipment_space_type_name_tags": "parking area, interior" + }, + { + "support_electric_equipment_space_type_name_tags": "audience seating - gymnasium" + }, + { + "support_electric_equipment_space_type_name_tags": "emergency room" + }, + { + "support_electric_equipment_space_type_name_tags": "patient room" + }, + { + "support_electric_equipment_space_type_name_tags": "corridor - hospital" + }, + { + "support_electric_equipment_space_type_name_tags": "fellowship hall - religious facility" + }, + { + "support_electric_equipment_space_type_name_tags": "lounge/breakroom - healthcare facility" + }, + { + "support_electric_equipment_space_type_name_tags": "operating room" + }, + { + "support_electric_equipment_space_type_name_tags": "physical therapy" + }, + { + "support_electric_equipment_space_type_name_tags": "storage < 50 sf - hospital" + }, + { + "support_electric_equipment_space_type_name_tags": "storage 50 to 1000 sf - hospital" + }, + { + "support_electric_equipment_space_type_name_tags": "guest room" + }, + { + "support_electric_equipment_space_type_name_tags": "lobby - hotel" + }, + { + "support_electric_equipment_space_type_name_tags": "library - cataloging" + }, + { + "support_electric_equipment_space_type_name_tags": "museum exhibit area" + }, + { + "support_electric_equipment_space_type_name_tags": "corridor - manufacturing facility" + }, + { + "support_electric_equipment_space_type_name_tags": "manufacturing equipment room" + }, + { + "support_electric_equipment_space_type_name_tags": "manufacturing low bay" + }, + { + "support_electric_equipment_space_type_name_tags": "performing arts dressing room" + }, + { + "support_electric_equipment_space_type_name_tags": "audience seating - auditorium" + }, + { + "support_electric_equipment_space_type_name_tags": "audience seating - motion picture theater" + }, + { + "support_electric_equipment_space_type_name_tags": "lobby - motion picture theater" + }, + { + "support_electric_equipment_space_type_name_tags": "Dwelling Unit" + }, + { + "support_electric_equipment_space_type_name_tags": "museum restoration" + }, + { + "support_electric_equipment_space_type_name_tags": "banking activity" + }, + { + "support_electric_equipment_space_type_name_tags": "warehouse - fine storage" + }, + { + "support_electric_equipment_space_type_name_tags": "classroom/lecture/training - penitentiary" + }, + { + "support_electric_equipment_space_type_name_tags": "dining - penitentiary" + }, + { + "support_electric_equipment_space_type_name_tags": "audience seating - performing arts theater" + }, + { + "support_electric_equipment_space_type_name_tags": "lobby - performing arts theater" + }, + { + "support_electric_equipment_space_type_name_tags": "audience seating - religious facility" + }, + { + "support_electric_equipment_space_type_name_tags": "worship/pulpit/choir area" + }, + { + "support_electric_equipment_space_type_name_tags": "classroom/lecture/training - preschool to 12th" + }, + { + "support_electric_equipment_space_type_name_tags": "sports arena playing area, class II" + }, + { + "support_electric_equipment_space_type_name_tags": "audience seating - sports arena" + }, + { + "support_electric_equipment_space_type_name_tags": "airport concourse" + }, + { + "support_electric_equipment_space_type_name_tags": "atrium < 20 ft height" + }, + { + "support_electric_equipment_space_type_name_tags": "atrium > 40 ft height" + }, + { + "support_electric_equipment_space_type_name_tags": "atrium >= 20 ft and <= 40 ft in height" + }, + { + "support_electric_equipment_space_type_name_tags": "baggage/carousel" + }, + { + "support_electric_equipment_space_type_name_tags": "seating area, general" + }, + { + "support_electric_equipment_space_type_name_tags": "transportation ticket counter" + }, + { + "support_electric_equipment_space_type_name_tags": "warehouse - bulk storage" + }, + { + "support_electric_equipment_space_type_name_tags": "workshop" + }, + { + "support_electric_equipment_space_type_name_tags": "gymnasium_playing_area" + }, + { + "support_electric_equipment_space_type_name_tags": "gymnasium_exercise_area" + }, + { + "support_electric_equipment_space_type_name_tags": "courtroom" + }, + { + "support_electric_equipment_space_type_name_tags": "confinement_cells" + }, + { + "support_electric_equipment_space_type_name_tags": "judges_chambers" + }, + { + "support_electric_equipment_space_type_name_tags": "emergency_vehicle_garage" + }, + { + "support_electric_equipment_space_type_name_tags": "firestation_sleeping_quarters" + }, + { + "support_electric_equipment_space_type_name_tags": "post_office_sorting_area" + }, + { + "support_electric_equipment_space_type_name_tags": "exhibit_convention_center" + }, + { + "support_electric_equipment_space_type_name_tags": "library_cataloging" + }, + { + "support_electric_equipment_space_type_name_tags": "library_stacks" + }, + { + "support_electric_equipment_space_type_name_tags": "library_reading" + }, + { + "support_electric_equipment_space_type_name_tags": "emergency_room" + }, + { + "support_electric_equipment_space_type_name_tags": "recovery" + }, + { + "support_electric_equipment_space_type_name_tags": "nurses_station" + }, + { + "support_electric_equipment_space_type_name_tags": "exam_treatment" + }, + { + "support_electric_equipment_space_type_name_tags": "pharmacy" + }, + { + "support_electric_equipment_space_type_name_tags": "patient_room" + }, + { + "support_electric_equipment_space_type_name_tags": "operating_room" + }, + { + "support_electric_equipment_space_type_name_tags": "nursery" + }, + { + "support_electric_equipment_space_type_name_tags": "medical_supply" + }, + { + "support_electric_equipment_space_type_name_tags": "physical_therapy" + }, + { + "support_electric_equipment_space_type_name_tags": "imaging" + }, + { + "support_electric_equipment_space_type_name_tags": "laundry_washing" + }, + { + "support_electric_equipment_space_type_name_tags": "automotive" + }, + { + "support_electric_equipment_space_type_name_tags": "manufacturing_low_bay" + }, + { + "support_electric_equipment_space_type_name_tags": "manufacturing_high_bay" + }, + { + "support_electric_equipment_space_type_name_tags": "detailed_manufacuring" + }, + { + "support_electric_equipment_space_type_name_tags": "manufacturing_equipment_room" + }, + { + "support_electric_equipment_space_type_name_tags": "manufacturing_control" + }, + { + "support_electric_equipment_space_type_name_tags": "manufacturing_extra_high_bay" + }, + { + "support_electric_equipment_space_type_name_tags": "guest_room" + }, + { + "support_electric_equipment_space_type_name_tags": "dormitory_living_quarters" + }, + { + "support_electric_equipment_space_type_name_tags": "museum_exhibit_area" + }, + { + "support_electric_equipment_space_type_name_tags": "museum_restoration" + }, + { + "support_electric_equipment_space_type_name_tags": "banking_activity" + }, + { + "support_electric_equipment_space_type_name_tags": "worship_pulpit_choir_area" + }, + { + "support_electric_equipment_space_type_name_tags": "fellowship_hall_religious_facility" + }, + { + "support_electric_equipment_space_type_name_tags": "sales" + }, + { + "support_electric_equipment_space_type_name_tags": "retail_mall_concourse" + }, + { + "support_electric_equipment_space_type_name_tags": "retail_dressing_room" + }, + { + "support_electric_equipment_space_type_name_tags": "sports_arena_ring_sports_area" + }, + { + "support_electric_equipment_space_type_name_tags": "sports_arena_court_sports_area" + }, + { + "support_electric_equipment_space_type_name_tags": "sports_arena_indoor_playing_field" + }, + { + "support_electric_equipment_space_type_name_tags": "sports_arena_playing_area_class_I" + }, + { + "support_electric_equipment_space_type_name_tags": "sports_arena_playing_area_class_II" + }, + { + "support_electric_equipment_space_type_name_tags": "sports_arena_playing_area_class_III" + }, + { + "support_electric_equipment_space_type_name_tags": "sports_arena_playing_area_class_IV" + }, + { + "support_electric_equipment_space_type_name_tags": "warehouse_fine_storage" + }, + { + "support_electric_equipment_space_type_name_tags": "warehouse_bulk_storage" + }, + { + "support_electric_equipment_space_type_name_tags": "parking_area_interior" + }, + { + "support_electric_equipment_space_type_name_tags": "airport_concourse" + }, + { + "support_electric_equipment_space_type_name_tags": "baggage_carousel" + }, + { + "support_electric_equipment_space_type_name_tags": "transportation_ticket_counter" + }, + { + "support_electric_equipment_space_type_name_tags": "sales_display_type_1" + }, + { + "support_electric_equipment_space_type_name_tags": "sales_display_type_2" + }, + { + "support_electric_equipment_space_type_name_tags": "sales_display_type_3" + }, + { + "support_electric_equipment_space_type_name_tags": "sales_display_type_4" + }, + { + "support_electric_equipment_space_type_name_tags": "breakroom" + }, + { + "support_electric_equipment_space_type_name_tags": "copy_print" + }, + { + "support_electric_equipment_space_type_name_tags": "computer_room" + }, + { + "support_electric_equipment_space_type_name_tags": "loading_dock" + }, + { + "support_electric_equipment_space_type_name_tags": "locker_room" + }, + { + "support_electric_equipment_space_type_name_tags": "seating_area_general" + }, + { + "support_electric_equipment_space_type_name_tags": "vehicular_maintenance" + }, + { + "support_electric_equipment_space_type_name_tags": "chapel_visually_impaired" + }, + { + "support_electric_equipment_space_type_name_tags": "recreation_common_living_visually_impaired" + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/support_lighting_space_type_name_tags.json b/data/openstudio_standards_data/database_files/support_lighting_space_type_name_tags.json new file mode 100644 index 0000000000..ec255589b7 --- /dev/null +++ b/data/openstudio_standards_data/database_files/support_lighting_space_type_name_tags.json @@ -0,0 +1,476 @@ +[ + { + "lighting_space_type_name": "bam_automotive_facility" + }, + { + "lighting_space_type_name": "bam_convention_center" + }, + { + "lighting_space_type_name": "bam_courthouse" + }, + { + "lighting_space_type_name": "bam_dinin_bar_lounge_leisure" + }, + { + "lighting_space_type_name": "bam_dining_cafeteria_fast_food" + }, + { + "lighting_space_type_name": "bam_dining_family" + }, + { + "lighting_space_type_name": "bam_dormitory" + }, + { + "lighting_space_type_name": "bam_exercise_center" + }, + { + "lighting_space_type_name": "bam_fire_station" + }, + { + "lighting_space_type_name": "bam_gymnasium" + }, + { + "lighting_space_type_name": "bam_healthcare_clinic" + }, + { + "lighting_space_type_name": "bam_hospital" + }, + { + "lighting_space_type_name": "bam_hotel" + }, + { + "lighting_space_type_name": "bam_library" + }, + { + "lighting_space_type_name": "bam_manufacturing_facility" + }, + { + "lighting_space_type_name": "bam_motel" + }, + { + "lighting_space_type_name": "bam_motion_picture_theater" + }, + { + "lighting_space_type_name": "bam_multifamily" + }, + { + "lighting_space_type_name": "bam_museum" + }, + { + "lighting_space_type_name": "bam_office" + }, + { + "lighting_space_type_name": "bam_parking_garage" + }, + { + "lighting_space_type_name": "bam_penitentiary" + }, + { + "lighting_space_type_name": "bam_performing_arts_theater" + }, + { + "lighting_space_type_name": "bam_police_station" + }, + { + "lighting_space_type_name": "bam_post_office" + }, + { + "lighting_space_type_name": "bam_religious_facility" + }, + { + "lighting_space_type_name": "bam_retail" + }, + { + "lighting_space_type_name": "bam_school_university" + }, + { + "lighting_space_type_name": "bam_sports_arena" + }, + { + "lighting_space_type_name": "bam_town_hall" + }, + { + "lighting_space_type_name": "bam_transportation" + }, + { + "lighting_space_type_name": "bam_warehouse" + }, + { + "lighting_space_type_name": "bam_workshop" + }, + { + "lighting_space_type_name": "office_enclosed_small" + }, + { + "lighting_space_type_name": "office_enclosed_large" + }, + { + "lighting_space_type_name": "office_open" + }, + { + "lighting_space_type_name": "conference_meeting_multipurpose" + }, + { + "lighting_space_type_name": "classroom_lecture_training_general" + }, + { + "lighting_space_type_name": "classroom_lecture_training_penitentiary" + }, + { + "lighting_space_type_name": "lobby_general" + }, + { + "lighting_space_type_name": "lobby_hotel" + }, + { + "lighting_space_type_name": "lobby_performing_arts_theater" + }, + { + "lighting_space_type_name": "lobby_motion_picture_theater" + }, + { + "lighting_space_type_name": "lobby_visually_impaired" + }, + { + "lighting_space_type_name": "lobby_elevator" + }, + { + "lighting_space_type_name": "audience_seating_general" + }, + { + "lighting_space_type_name": "audience_seating_gymnasium" + }, + { + "lighting_space_type_name": "audience_seating_exercise_center" + }, + { + "lighting_space_type_name": "audience_seating_convention_center" + }, + { + "lighting_space_type_name": "audience_seating_penitentiary" + }, + { + "lighting_space_type_name": "audience_seating_religious_facility" + }, + { + "lighting_space_type_name": "audience_seating_sports_arena" + }, + { + "lighting_space_type_name": "audience_seating_performing_arts_theater" + }, + { + "lighting_space_type_name": "audience_seating_motion_picture_theater" + }, + { + "lighting_space_type_name": "audience_seating_transportation" + }, + { + "lighting_space_type_name": "audience_seating_auditorium" + }, + { + "lighting_space_type_name": "atrium_first_three_floor" + }, + { + "lighting_space_type_name": "atrium_each_additional_floor" + }, + { + "lighting_space_type_name": "atrium_low" + }, + { + "lighting_space_type_name": "atrium_medium" + }, + { + "lighting_space_type_name": "atrium_high" + }, + { + "lighting_space_type_name": "lounge_breakroom_general" + }, + { + "lighting_space_type_name": "lounge_breakroom_healthcare_facility" + }, + { + "lighting_space_type_name": "dining_general" + }, + { + "lighting_space_type_name": "dining_penitentiary" + }, + { + "lighting_space_type_name": "dining_hotel" + }, + { + "lighting_space_type_name": "dining_motel" + }, + { + "lighting_space_type_name": "dining_bar_lounge_leisure" + }, + { + "lighting_space_type_name": "dining_family" + }, + { + "lighting_space_type_name": "dining_cafeteria_fast_food" + }, + { + "lighting_space_type_name": "dining_visually_impaired" + }, + { + "lighting_space_type_name": "kitchen" + }, + { + "lighting_space_type_name": "laboratory_classroom" + }, + { + "lighting_space_type_name": "laboratory_all_other" + }, + { + "lighting_space_type_name": "restroom_visually_impaired" + }, + { + "lighting_space_type_name": "restroom_all_other" + }, + { + "lighting_space_type_name": "performing_arts_dressing_room" + }, + { + "lighting_space_type_name": "corridor_general" + }, + { + "lighting_space_type_name": "corridor_hospital" + }, + { + "lighting_space_type_name": "corridor_manufacturing_facility" + }, + { + "lighting_space_type_name": "corridor_visually_impaired" + }, + { + "lighting_space_type_name": "stairway" + }, + { + "lighting_space_type_name": "stairwell" + }, + { + "lighting_space_type_name": "storage_ all_other_small" + }, + { + "lighting_space_type_name": "storage_ all_other_large" + }, + { + "lighting_space_type_name": "storage_hospital_small" + }, + { + "lighting_space_type_name": "storage_hospital_large" + }, + { + "lighting_space_type_name": "storage_inactive" + }, + { + "lighting_space_type_name": "storage_inactive_museum" + }, + { + "lighting_space_type_name": "electrical_mechanical" + }, + { + "lighting_space_type_name": "workshop" + }, + { + "lighting_space_type_name": "gymnasium_playing_area" + }, + { + "lighting_space_type_name": "gymnasium_exercise_area" + }, + { + "lighting_space_type_name": "courtroom" + }, + { + "lighting_space_type_name": "confinement_cells" + }, + { + "lighting_space_type_name": "judges_chambers" + }, + { + "lighting_space_type_name": "emergency_vehicle_garage" + }, + { + "lighting_space_type_name": "firestation_sleeping_quarters" + }, + { + "lighting_space_type_name": "post_office_sorting_area" + }, + { + "lighting_space_type_name": "exhibit_convention_center" + }, + { + "lighting_space_type_name": "library_cataloging" + }, + { + "lighting_space_type_name": "library_stacks" + }, + { + "lighting_space_type_name": "library_reading" + }, + { + "lighting_space_type_name": "emergency_room" + }, + { + "lighting_space_type_name": "recovery" + }, + { + "lighting_space_type_name": "nurses_station" + }, + { + "lighting_space_type_name": "exam_treatment" + }, + { + "lighting_space_type_name": "pharmacy" + }, + { + "lighting_space_type_name": "patient_room" + }, + { + "lighting_space_type_name": "operating_room" + }, + { + "lighting_space_type_name": "nursery" + }, + { + "lighting_space_type_name": "medical_supply" + }, + { + "lighting_space_type_name": "physical_therapy" + }, + { + "lighting_space_type_name": "imaging" + }, + { + "lighting_space_type_name": "laundry_washing" + }, + { + "lighting_space_type_name": "automotive" + }, + { + "lighting_space_type_name": "manufacturing_low_bay" + }, + { + "lighting_space_type_name": "manufacturing_high_bay" + }, + { + "lighting_space_type_name": "detailed_manufacuring" + }, + { + "lighting_space_type_name": "manufacturing_equipment_room" + }, + { + "lighting_space_type_name": "manufacturing_control" + }, + { + "lighting_space_type_name": "manufacturing_extra_high_bay" + }, + { + "lighting_space_type_name": "guest_room" + }, + { + "lighting_space_type_name": "dormitory_living_quarters" + }, + { + "lighting_space_type_name": "museum_exhibit_area" + }, + { + "lighting_space_type_name": "museum_restoration" + }, + { + "lighting_space_type_name": "banking_activity" + }, + { + "lighting_space_type_name": "worship_pulpit_choir_area" + }, + { + "lighting_space_type_name": "fellowship_hall_religious_facility" + }, + { + "lighting_space_type_name": "sales" + }, + { + "lighting_space_type_name": "retail_mall_concourse" + }, + { + "lighting_space_type_name": "retail_dressing_room" + }, + { + "lighting_space_type_name": "sports_arena_ring_sports_area" + }, + { + "lighting_space_type_name": "sports_arena_court_sports_area" + }, + { + "lighting_space_type_name": "sports_arena_indoor_playing_field" + }, + { + "lighting_space_type_name": "sports_arena_playing_area_class_I" + }, + { + "lighting_space_type_name": "sports_arena_playing_area_class_II" + }, + { + "lighting_space_type_name": "sports_arena_playing_area_class_III" + }, + { + "lighting_space_type_name": "sports_arena_playing_area_class_IV" + }, + { + "lighting_space_type_name": "warehouse_fine_storage" + }, + { + "lighting_space_type_name": "warehouse_bulk_storage" + }, + { + "lighting_space_type_name": "parking_area_interior" + }, + { + "lighting_space_type_name": "airport_concourse" + }, + { + "lighting_space_type_name": "baggage_carousel" + }, + { + "lighting_space_type_name": "transportation_ticket_counter" + }, + { + "lighting_space_type_name": "sales_display_type_1" + }, + { + "lighting_space_type_name": "sales_display_type_2" + }, + { + "lighting_space_type_name": "sales_display_type_3" + }, + { + "lighting_space_type_name": "sales_display_type_4" + }, + { + "lighting_space_type_name": "breakroom" + }, + { + "lighting_space_type_name": "copy_print" + }, + { + "lighting_space_type_name": "computer_room" + }, + { + "lighting_space_type_name": "loading_dock" + }, + { + "lighting_space_type_name": "locker_room" + }, + { + "lighting_space_type_name": "seating_area_general" + }, + { + "lighting_space_type_name": "vehicular_maintenance" + }, + { + "lighting_space_type_name": "chapel_visually_impaired" + }, + { + "lighting_space_type_name": "recreation_common_living_visually_impaired" + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/support_materials.csv b/data/openstudio_standards_data/database_files/support_materials.csv index 2033106c5e..304cf74d9d 100644 --- a/data/openstudio_standards_data/database_files/support_materials.csv +++ b/data/openstudio_standards_data/database_files/support_materials.csv @@ -464,7 +464,7 @@ Hard Board - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,0.72,1.041666667,50,0.31 Hardboard - HDF - 50 lb/ft3 - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.7296,0.685307018,50,0.31,,,,,,,,,,,,,,,,,,,,, Hardboard - HDF - 50 lb/ft3 - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,0.7296,1.027960526,50,0.31,,,,,,,,,,,,,,,,,,,,, Hardboard - HDF - 50 lb/ft3 - 3/8 in.,StandardOpaqueMaterial,Smooth,0.38,0.7296,0.520833333,50,0.31,,,,,,,,,,,,,,,,,,,,, -Hardboard - HDF - 50 lb/ft3 - 5/8 in.,StandardOpaqueMaterial,Smooth,6.30E-01,0.7296,8.63E-01,50,0.31,,,,,,,,,,,,,,,,,,,,, +Hardboard - HDF - 50 lb/ft3 - 5/8 in.,StandardOpaqueMaterial,Smooth,0.63,0.7296,0.863,50,0.31,,,,,,,,,,,,,,,,,,,,, Hardwood - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,1.1604,0.861771803,42.43,0.39,,,,,,,,,,,,,,,,,,,,, Hardwood - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,1.1604,0.430885901,42.43,0.39,,,,,,,,,,,,,,,,,,,,, Hardwood - 3/4 in.,StandardOpaqueMaterial,MediumSmooth,0.75,1.1604,0.646328852,42.43,0.39,,,,,,,,,,,,,,,,,,,,, @@ -496,7 +496,7 @@ Insulating Concrete Forms - 4 in. EPS Ins. each side - concrete 8 in.,StandardOp Insulating Concrete Forms - 4 in. XPS Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,14,0.3504,39.9543379,64.86,0.23,,,,,,,,,,,,,,,,,,,,, Insulating Concrete Forms - 4 in. XPS Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,16,0.39,41.02564103,75.5,0.22,,,,,,,,,,,,,,,,,,,,, Insulation 1m,StandardOpaqueMaterial,Smooth,39.37,0.13876,,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -Interior Wall Addi Insul,StandardOpaqueMaterial,MediumRough,1.00E-06,0.299941999,3.33E-06,1.399999086,0.199866248,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, +Interior Wall Addi Insul,StandardOpaqueMaterial,MediumRough,1e-06,0.299941999,3.33e-06,1.399999086,0.199866248,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, Light Roof - 2/5 in.,StandardOpaqueMaterial,VeryRough,0.2,2.4012,0.083291687,120,0.2,,,,,,,,,,,,,,,,,,,,, Linoleum/cork tile - 1/4 in.,StandardOpaqueMaterial,MediumRough,0.25,0.51,0.490196078,29,0.45,,,,,,,,,,,,,,,,,,,,, LoE CLEAR 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.6,0.17,0.22,0.84,0.055,0.078,0,0.84,0.1,1,FALSE,, diff --git a/data/openstudio_standards_data/database_files/support_materials.json b/data/openstudio_standards_data/database_files/support_materials.json new file mode 100644 index 0000000000..5986c21f9c --- /dev/null +++ b/data/openstudio_standards_data/database_files/support_materials.json @@ -0,0 +1,43061 @@ +[ + { + "name": "1 Coat Stucco", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 0.38, + "conductivity": 5.0004, + "resistance": 0.07599392, + "density": 115.81, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "1/2 in. Gypsum Board", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.5, + "conductivity": 1.109355488, + "resistance": 0.450712153, + "density": 49.94236846, + "specific_heat": 0.260342027, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.5, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "1/2IN Gypsum", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.5, + "conductivity": 1.109355488, + "resistance": 0.450712153, + "density": 48.99970626, + "specific_heat": 0.198242094, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.4, + "visible_absorptance": 0.4, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "10 PSF Roof - 1 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "VeryRough", + "thickness": 1, + "conductivity": 12.0048, + "resistance": 0.083300013, + "density": 120, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "100mm Normalweight concrete floor", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 4, + "conductivity": 16.0194175, + "resistance": 0.249696969, + "density": 144.957816, + "specific_heat": 0.198852772, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "12 in. Normalweight Concrete Floor", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 12, + "conductivity": 16.01631985, + "resistance": 0.749235786, + "density": 144.9577245, + "specific_heat": 0.198719786, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "15 PSF Roof - 1 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "VeryRough", + "thickness": 1.5, + "conductivity": 18.0072, + "resistance": 0.083300013, + "density": 120, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "1IN Stucco", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.996062992, + "conductivity": 4.79657579, + "resistance": 0.207661264, + "density": 115.9911508, + "specific_heat": 0.199914015, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.92, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "25 PSF Roof - 2 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "VeryRough", + "thickness": 2.5, + "conductivity": 30.012, + "resistance": 0.083300013, + "density": 120, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "25mm Stucco", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 1, + "conductivity": 4.992099695, + "resistance": 0.200316512, + "density": 115.8662948, + "specific_heat": 0.200630553, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "3 Coat Stucco", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 0.88, + "conductivity": 4.3752, + "resistance": 0.201133662, + "density": 116, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "4 in. Normalweight Concrete Floor", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 4, + "conductivity": 16.01631985, + "resistance": 0.249745262, + "density": 144.9577245, + "specific_heat": 0.198719786, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "4 in. Normalweight Concrete Wall", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 4, + "conductivity": 16.01631985, + "resistance": 0.249745262, + "density": 144.9577245, + "specific_heat": 0.198719786, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "5 PSF Roof - 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "VeryRough", + "thickness": 0.5, + "conductivity": 6.0024, + "resistance": 0.083300013, + "density": 120, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "5/8 in. Gypsum Board", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.625984252, + "conductivity": 1.109355488, + "resistance": 0.56427742, + "density": 49.94236846, + "specific_heat": 0.260342027, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "5/8 in. Plywood", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.625984252, + "conductivity": 0.832016616, + "resistance": 0.752369893, + "density": 33.96081055, + "specific_heat": 0.289003535, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "6 in. Heavyweight Concrete Roof", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 6, + "conductivity": 16.01631985, + "resistance": 0.374617893, + "density": 144.9577245, + "specific_heat": 0.198719786, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "6 in. Normalweight Concrete Floor", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 6, + "conductivity": 16.01631985, + "resistance": 0.374617893, + "density": 144.9577245, + "specific_heat": 0.198719786, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "8 in. Concrete Block Basement Wall", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 8, + "conductivity": 9.193783605, + "resistance": 0.870153176, + "density": 114.9923034, + "specific_heat": 0.217827458, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "8 in. Concrete Block Wall", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 8, + "conductivity": 4.992099695, + "resistance": 1.602532098, + "density": 49.94236846, + "specific_heat": 0.198719786, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "8 in. Normalweight Concrete Floor", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 8, + "conductivity": 16.01631985, + "resistance": 0.499490524, + "density": 144.9577245, + "specific_heat": 0.198719786, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "8 in. Normalweight Concrete Wall", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 8, + "conductivity": 16.01631985, + "resistance": 0.499490524, + "density": 144.9577245, + "specific_heat": 0.198719786, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "8IN Concrete HW", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 8.003937008, + "conductivity": 11.99213282, + "resistance": 0.667432318, + "density": 140.0259156, + "specific_heat": 0.199914015, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.65, + "visible_absorptance": 0.65, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "8IN CONCRETE HW RefBldg", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 8, + "conductivity": 9.089781528, + "resistance": 0.880109162, + "density": 139.8386317, + "specific_heat": 0.199866246, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Acoustic Ceiling", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.5, + "conductivity": 0.395207893, + "resistance": 1.26515692, + "density": 17.97925265, + "specific_heat": 0.319814656, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.2, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Acoustic Tile - 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.5, + "conductivity": 0.3996, + "resistance": 1.251251251, + "density": 18, + "specific_heat": 0.19, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Acoustic Tile - 3/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.75, + "conductivity": 0.3996, + "resistance": 1.876876877, + "density": 18, + "specific_heat": 0.19, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Acoustic Tile - 3/8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.38, + "conductivity": 0.39, + "resistance": 0.974358974, + "density": 18, + "specific_heat": 0.19, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Adiabatic Material", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 9999, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aggregate - 45 lb/ft3 - 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.5, + "conductivity": 1.56, + "resistance": 0.320512821, + "density": 45, + "specific_heat": 0.32, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aggregate - 45 lb/ft3 - 5/8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.63, + "conductivity": 1.5996, + "resistance": 0.393848462, + "density": 45, + "specific_heat": 0.32, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aggregate - 45 lb/ft3 - on metal lath - 3/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.75, + "conductivity": 1.5996, + "resistance": 0.468867217, + "density": 45, + "specific_heat": 0.32, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aggregate - Perlite - 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.5, + "conductivity": 1.2996, + "resistance": 0.384733764, + "density": 45, + "specific_heat": 0.32, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aggregate - Perlite - 5/8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.63, + "conductivity": 1.5, + "resistance": 0.42, + "density": 45, + "specific_heat": 0.32, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aggregate - Perlite - on metal lath - 3/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.75, + "conductivity": 1.7004, + "resistance": 0.441072689, + "density": 45, + "specific_heat": 0.32, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Air - Cavity - Wall Roof Ceiling - 4 in. or more", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6, + "conductivity": 6.5196, + "resistance": 0.920301859, + "density": 0.08, + "specific_heat": 0.24, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Air - Ceiling - 1 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 1.5, + "conductivity": 1.95, + "resistance": 0.769230769, + "density": 0.08, + "specific_heat": 0.24, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Air - Ceiling - 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.5, + "conductivity": 0.6804, + "resistance": 0.734861846, + "density": 0.08, + "specific_heat": 0.24, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Air - Ceiling - 3 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 3.5, + "conductivity": 4.38, + "resistance": 0.799086758, + "density": 0.08, + "specific_heat": 0.24, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Air - Ceiling - 3/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.75, + "conductivity": 0.9996, + "resistance": 0.75030012, + "density": 0.08, + "specific_heat": 0.24, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Air - Floor - 1 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 1.5, + "conductivity": 1.5996, + "resistance": 0.937734434, + "density": 0.08, + "specific_heat": 0.24, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Air - Floor - 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.5, + "conductivity": 0.6504, + "resistance": 0.768757688, + "density": 0.08, + "specific_heat": 0.24, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Air - Floor - 3 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 3.5, + "conductivity": 3.5004, + "resistance": 0.999885727, + "density": 0.08, + "specific_heat": 0.24, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Air - Floor - 3/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.75, + "conductivity": 0.8796, + "resistance": 0.8526603, + "density": 0.08, + "specific_heat": 0.24, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Air - Metal Wall Framing - 16 or 24 in. OC", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 5.5, + "conductivity": 8.46, + "resistance": 0.650118203, + "density": 0.08, + "specific_heat": 0.24, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Air - Roof - 1 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 1.5, + "conductivity": 1.8804, + "resistance": 0.797702616, + "density": 0.08, + "specific_heat": 0.24, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Air - Roof - 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.5, + "conductivity": 0.66, + "resistance": 0.757575758, + "density": 0.08, + "specific_heat": 0.24, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Air - Roof - 3 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 3.5, + "conductivity": 4.2696, + "resistance": 0.819748923, + "density": 0.08, + "specific_heat": 0.24, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Air - Roof - 3/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.75, + "conductivity": 0.93, + "resistance": 0.806451613, + "density": 0.08, + "specific_heat": 0.24, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Air - Wall - 1 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 1.5, + "conductivity": 1.7196, + "resistance": 0.872295883, + "density": 0.08, + "specific_heat": 0.24, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Air - Wall - 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.5, + "conductivity": 0.6504, + "resistance": 0.768757688, + "density": 0.08, + "specific_heat": 0.24, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Air - Wall - 3 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 3.5, + "conductivity": 4.1196, + "resistance": 0.849597048, + "density": 0.08, + "specific_heat": 0.24, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Air - Wall - 3/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.75, + "conductivity": 0.8904, + "resistance": 0.842318059, + "density": 0.08, + "specific_heat": 0.24, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "AIR 13MM", + "material_type": "Gas", + "roughness": null, + "thickness": 0.5, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": "Air", + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "AIR 3MM", + "material_type": "Gas", + "roughness": null, + "thickness": 0.125984252, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": "Air", + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "AIR 6MM", + "material_type": "Gas", + "roughness": null, + "thickness": 0.248031496, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": "Air", + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/ Thrml Break - Double glass with no low e - No Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.27, + "conductivity": 0.9, + "resistance": 2.522222222, + "density": 29.09, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/ Thrml Break - Double glass with no low e - R10 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 3.27, + "conductivity": 0.8196, + "resistance": 3.989751098, + "density": 20.44, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/ Thrml Break - Double glass with no low e - R15 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 4.47, + "conductivity": 1.08, + "resistance": 4.138888889, + "density": 15.23, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/ Thrml Break - Double glass with no low e - R20 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 5.67, + "conductivity": 1.3296, + "resistance": 4.264440433, + "density": 12.22, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/ Thrml Break - Double glass with no low e - R25 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.87, + "conductivity": 1.5996, + "resistance": 4.294823706, + "density": 10.26, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/ Thrml Break - Double glass with no low e - R30 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 8.07, + "conductivity": 1.8504, + "resistance": 4.361219196, + "density": 8.88, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/ Thrml Break - Double glass with no low e - R4 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 1.83, + "conductivity": 0.5304, + "resistance": 3.450226244, + "density": 35.69, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/ Thrml Break - Double glass with no low e - R7 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.55, + "conductivity": 0.6696, + "resistance": 3.808243728, + "density": 25.92, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - No Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.27, + "conductivity": 1.1796, + "resistance": 1.924381146, + "density": 29.09, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R10 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 3.27, + "conductivity": 0.8496, + "resistance": 3.848870056, + "density": 20.44, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R15 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 4.47, + "conductivity": 1.1004, + "resistance": 4.062159215, + "density": 15.23, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R20 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 5.67, + "conductivity": 1.35, + "resistance": 4.2, + "density": 12.22, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R25 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.87, + "conductivity": 1.6104, + "resistance": 4.266020864, + "density": 10.26, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R30 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 8.07, + "conductivity": 1.86, + "resistance": 4.338709677, + "density": 8.88, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R4 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 1.83, + "conductivity": 0.5604, + "resistance": 3.265524625, + "density": 35.69, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R7 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.55, + "conductivity": 0.6996, + "resistance": 3.644939966, + "density": 25.92, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/ Thrml Break - Triple or low e glass - No Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.27, + "conductivity": 0.78, + "resistance": 2.91025641, + "density": 29.09, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/ Thrml Break - Triple or low e glass - R10 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 3.27, + "conductivity": 0.8196, + "resistance": 3.989751098, + "density": 20.44, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/ Thrml Break - Triple or low e glass - R15 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 4.47, + "conductivity": 1.08, + "resistance": 4.138888889, + "density": 15.23, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/ Thrml Break - Triple or low e glass - R20 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 5.67, + "conductivity": 1.3296, + "resistance": 4.264440433, + "density": 12.22, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/ Thrml Break - Triple or low e glass - R25 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.87, + "conductivity": 1.5996, + "resistance": 4.294823706, + "density": 10.26, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/ Thrml Break - Triple or low e glass - R30 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 8.07, + "conductivity": 1.8504, + "resistance": 4.361219196, + "density": 8.88, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/ Thrml Break - Triple or low e glass - R4 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 1.83, + "conductivity": 0.51, + "resistance": 3.588235294, + "density": 35.69, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/ Thrml Break - Triple or low e glass - R7 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.55, + "conductivity": 0.6696, + "resistance": 3.808243728, + "density": 25.92, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/out Thrml Break - Double glass with no low e coatings - No Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.27, + "conductivity": 0.8304, + "resistance": 2.733622351, + "density": 29.09, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/out Thrml Break - Double glass with no low e coatings - R10 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 3.27, + "conductivity": 0.6504, + "resistance": 5.027675277, + "density": 20.44, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/out Thrml Break - Double glass with no low e coatings - R15 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 4.47, + "conductivity": 0.8304, + "resistance": 5.382947977, + "density": 15.23, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/out Thrml Break - Double glass with no low e coatings - R20 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 5.67, + "conductivity": 1.00464, + "resistance": 5.643812709, + "density": 12.22, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/out Thrml Break - Double glass with no low e coatings - R25 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.87, + "conductivity": 1.1904, + "resistance": 5.771169355, + "density": 10.26, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/out Thrml Break - Double glass with no low e coatings - R30 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 8.07, + "conductivity": 1.3704, + "resistance": 5.888791594, + "density": 8.88, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/out Thrml Break - Double glass with no low e coatings - R4 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 1.83, + "conductivity": 0.4404, + "resistance": 4.155313351, + "density": 35.69, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/out Thrml Break - Double glass with no low e coatings - R7 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.55, + "conductivity": 0.54, + "resistance": 4.722222222, + "density": 25.92, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - No Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.27, + "conductivity": 1.1304, + "resistance": 2.008138712, + "density": 29.09, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R10 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 3.27, + "conductivity": 0.66, + "resistance": 4.954545455, + "density": 20.44, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R15 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 4.47, + "conductivity": 0.84, + "resistance": 5.321428571, + "density": 15.23, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R20 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 5.67, + "conductivity": 1.0104, + "resistance": 5.611638955, + "density": 12.22, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R25 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.87, + "conductivity": 1.1904, + "resistance": 5.771169355, + "density": 10.26, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R30 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 8.07, + "conductivity": 1.38, + "resistance": 5.847826087, + "density": 8.88, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R4 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 1.83, + "conductivity": 0.4704, + "resistance": 3.890306122, + "density": 35.69, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R7 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.55, + "conductivity": 0.5604, + "resistance": 4.550321199, + "density": 25.92, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/out Thrml Break - Triple or low e glass - No Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.27, + "conductivity": 0.69, + "resistance": 3.289855072, + "density": 29.09, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/out Thrml Break - Triple or low e glass - R10 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 3.27, + "conductivity": 0.63648, + "resistance": 5.137631976, + "density": 20.44, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/out Thrml Break - Triple or low e glass - R15 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 4.47, + "conductivity": 0.8196, + "resistance": 5.453879941, + "density": 15.23, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/out Thrml Break - Triple or low e glass - R20 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 5.67, + "conductivity": 0.9996, + "resistance": 5.672268908, + "density": 12.22, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/out Thrml Break - Triple or low e glass - R25 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.87, + "conductivity": 1.1796, + "resistance": 5.824008138, + "density": 10.26, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/out Thrml Break - Triple or low e glass - R30 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 8.07, + "conductivity": 1.3704, + "resistance": 5.888791594, + "density": 8.88, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/out Thrml Break - Triple or low e glass - R4 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 1.83, + "conductivity": 0.41724, + "resistance": 4.385964912, + "density": 35.69, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Aluminum w/out Thrml Break - Triple or low e glass - R7 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.55, + "conductivity": 0.5304, + "resistance": 4.807692308, + "density": 25.92, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "ARGON 13MM", + "material_type": "Gas", + "roughness": null, + "thickness": 0.5, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": "Argon", + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Asbestos or cement shingles - 3/8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "VeryRough", + "thickness": 0.38, + "conductivity": 1.7904, + "resistance": 0.212243074, + "density": 120, + "specific_heat": 0.24, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Ash - 1 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1, + "conductivity": 1.1004, + "resistance": 0.908760451, + "density": 40.06, + "specific_heat": 0.39, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Asphalt - bitumen with inert fill - 100 lb/ft3 - 3/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "VeryRough", + "thickness": 0.75, + "conductivity": 3, + "resistance": 0.25, + "density": 100, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Asphalt - bitumen with inert fill - 144 lb/ft3 - 3/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "VeryRough", + "thickness": 0.75, + "conductivity": 8.0004, + "resistance": 0.093745313, + "density": 144, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Asphalt roll roofing - 1/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "VeryRough", + "thickness": 0.25, + "conductivity": 1.6704, + "resistance": 0.149664751, + "density": 70, + "specific_heat": 0.36, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Asphalt Shingles", + "material_type": "StandardOpaqueMaterial", + "roughness": "VeryRough", + "thickness": 0.125984252, + "conductivity": 0.277338872, + "resistance": 0.454261067, + "density": 69.91931585, + "specific_heat": 0.30094583, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Asphalt shingles - 1/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "VeryRough", + "thickness": 0.25, + "conductivity": 0.5604, + "resistance": 0.446109921, + "density": 69.89, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "AtticFloor Insulation", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 9.366141732, + "conductivity": 0.339740118, + "resistance": 27.56854794, + "density": 16.54340955, + "specific_heat": 0.199866246, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Birch - 1 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1, + "conductivity": 1.1904, + "resistance": 0.840053763, + "density": 43.93, + "specific_heat": 0.39, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "BLUE 6MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.236220472, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.48, + "front_side_solar_reflectance_at_normal_incidence": 0.05, + "back_side_solar_reflectance_at_normal_incidence": 0.05, + "visible_transmittance_at_normal_incidence": 0.57, + "front_side_visible_reflectance_at_normal_incidence": 0.06, + "back_side_visible_reflectance_at_normal_incidence": 0.06, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.84, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "Brick - 48 lb/ft3 - 3 5/8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 3.63, + "conductivity": 1.5, + "resistance": 2.42, + "density": 48, + "specific_heat": 0.19, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Brick - fired clay - 140 lb/ft3 - 3 5/8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 3.63, + "conductivity": 8.22, + "resistance": 0.441605839, + "density": 139.78, + "specific_heat": 0.19, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "BRONZE 6MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.236220472, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.482, + "front_side_solar_reflectance_at_normal_incidence": 0.054, + "back_side_solar_reflectance_at_normal_incidence": 0.054, + "visible_transmittance_at_normal_incidence": 0.534, + "front_side_visible_reflectance_at_normal_incidence": 0.057, + "back_side_visible_reflectance_at_normal_incidence": 0.057, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.84, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "Building Paper - 1/16 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.06, + "conductivity": 2.0004, + "resistance": 0.029994001, + "density": 70, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Built-up Roofing", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 0.374015748, + "conductivity": 1.109355488, + "resistance": 0.337146886, + "density": 69.91931585, + "specific_heat": 0.348715009, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Built-up roofing - 3/8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "VeryRough", + "thickness": 0.38, + "conductivity": 1.14, + "resistance": 0.333333333, + "density": 70, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Built-up Roofing - Highly Reflective", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 0.374015748, + "conductivity": 1.109355488, + "resistance": 0.337146886, + "density": 69.91931585, + "specific_heat": 0.348715009, + "thermal_absorptance": 0.75, + "solar_absorptance": 0.45, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Bulk Storage Products Material", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 96.0001946, + "conductivity": 9.998066642, + "resistance": 9.601875846, + "density": 12.49999184, + "specific_heat": 0.199866248, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "California Redwood - 1 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1, + "conductivity": 0.78, + "resistance": 1.282051282, + "density": 26.21, + "specific_heat": 0.39, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Carpet - 3/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 0.75, + "conductivity": 0.3156, + "resistance": 2.376425856, + "density": 18, + "specific_heat": 0.33, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Carpet - 3/4 in. CBES", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.75, + "conductivity": 0.34691, + "resistance": null, + "density": 18, + "specific_heat": 0.33, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.8, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "ceiling_2_Insulation", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 3.96766, + "conductivity": 0.15963, + "resistance": null, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.8, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Cellular polyisocyanurate (unfaced) - 1 1/2 in. R8.8", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 1.5, + "conductivity": 0.1704, + "resistance": 8.802816901, + "density": 1.5, + "specific_heat": 0.38, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Cellular polyisocyanurate (unfaced) - 1 in. R5.9", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 1, + "conductivity": 0.1704, + "resistance": 5.868544601, + "density": 1.5, + "specific_heat": 0.38, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Cellular polyisocyanurate (unfaced) - 1/2 in. R2.9", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 0.5, + "conductivity": 0.1704, + "resistance": 2.9342723, + "density": 1.5, + "specific_heat": 0.38, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Cellular polyisocyanurate (unfaced) - 1/4 in. R1.5", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 0.25, + "conductivity": 0.1704, + "resistance": 1.46713615, + "density": 1.5, + "specific_heat": 0.38, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Cellular polyisocyanurate (unfaced) - 1/8 in. R0.7", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 0.13, + "conductivity": 0.1704, + "resistance": 0.762910798, + "density": 1.5, + "specific_heat": 0.38, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Cellular polyisocyanurate (unfaced) - 2 1/2 in. R15", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 2.5, + "conductivity": 0.1704, + "resistance": 14.6713615, + "density": 1.5, + "specific_heat": 0.38, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Cellular polyisocyanurate (unfaced) - 2 in. R12", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 2, + "conductivity": 0.1704, + "resistance": 11.7370892, + "density": 1.5, + "specific_heat": 0.38, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Cellular polyisocyanurate (unfaced) - 3 1/2 in. R21", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 3.5, + "conductivity": 0.1704, + "resistance": 20.5399061, + "density": 1.5, + "specific_heat": 0.38, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Cellular polyisocyanurate (unfaced) - 3 in. R18", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 3, + "conductivity": 0.1704, + "resistance": 17.6056338, + "density": 1.5, + "specific_heat": 0.38, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Cellular polyisocyanurate (unfaced) - 4 1/2 in. R26", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 4.5, + "conductivity": 0.1704, + "resistance": 26.4084507, + "density": 1.5, + "specific_heat": 0.38, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Cellular polyisocyanurate (unfaced) - 4 in. R23", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 4, + "conductivity": 0.1704, + "resistance": 23.4741784, + "density": 1.5, + "specific_heat": 0.38, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Cellular polyisocyanurate (unfaced) - 5 1/2 in. R32", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 5.5, + "conductivity": 0.1704, + "resistance": 32.27699531, + "density": 1.5, + "specific_heat": 0.38, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Cellular polyisocyanurate (unfaced) - 5 in. R29", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 5, + "conductivity": 0.1704, + "resistance": 29.342723, + "density": 1.5, + "specific_heat": 0.38, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Cellular polyisocyanurate (unfaced) - 6 1/2 in. R38", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 6.5, + "conductivity": 0.1704, + "resistance": 38.14553991, + "density": 1.5, + "specific_heat": 0.38, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Cellular polyisocyanurate (unfaced) - 6 in. R35", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 6, + "conductivity": 0.1704, + "resistance": 35.21126761, + "density": 1.5, + "specific_heat": 0.38, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Clay - Part Grouted and Empty - 130 lb/ft3 - 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 6, + "conductivity": 3.12, + "resistance": 1.923076923, + "density": 130, + "specific_heat": 0.13, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Clay - Part Grouted and Empty - 130 lb/ft3 - 8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 8, + "conductivity": 3.7596, + "resistance": 2.127885945, + "density": 130, + "specific_heat": 0.13, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Clay - Part Grouted and Insulated - 130 lb/ft3 - 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 6, + "conductivity": 2.7, + "resistance": 2.222222222, + "density": 130, + "specific_heat": 0.13, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Clay - Part Grouted and Insulated - 130 lb/ft3 - 8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 8, + "conductivity": 3.12, + "resistance": 2.564102564, + "density": 130, + "specific_heat": 0.13, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Clay - Solid Grout - 130 lb/ft3 - 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 6, + "conductivity": 3.9, + "resistance": 1.538461538, + "density": 130, + "specific_heat": 0.17, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Clay - Solid Grout - 130 lb/ft3 - 8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 8, + "conductivity": 4.56, + "resistance": 1.754385965, + "density": 130, + "specific_heat": 0.17, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Clay tile - 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 0.5, + "conductivity": 0.1896, + "resistance": 2.637130802, + "density": 85, + "specific_heat": 0.21, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Clay tile - hollow - 1 cell deep - 3 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 3, + "conductivity": 3.75, + "resistance": 0.8, + "density": 85, + "specific_heat": 0.21, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Clay tile - hollow - 1 cell deep - 4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 4, + "conductivity": 3.6, + "resistance": 1.111111111, + "density": 85, + "specific_heat": 0.21, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Clay tile - hollow - 2 cells deep - 10 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 10, + "conductivity": 4.5, + "resistance": 2.222222222, + "density": 85, + "specific_heat": 0.21, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Clay tile - hollow - 2 cells deep - 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 6, + "conductivity": 3.9504, + "resistance": 1.518833536, + "density": 85, + "specific_heat": 0.21, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Clay tile - hollow - 2 cells deep - 8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 8, + "conductivity": 4.32, + "resistance": 1.851851852, + "density": 85, + "specific_heat": 0.21, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Clay tile - hollow - 3 cells deep - 12 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 12, + "conductivity": 4.8, + "resistance": 2.5, + "density": 85, + "specific_heat": 0.21, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Clay Tile - Paver", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 0.38, + "conductivity": 12.504, + "resistance": 0.030390275, + "density": 139.78, + "specific_heat": 0.22, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "CLEAR 2.5MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.098425197, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.8, + "front_side_solar_reflectance_at_normal_incidence": 0.075, + "back_side_solar_reflectance_at_normal_incidence": 0.075, + "visible_transmittance_at_normal_incidence": 0.901, + "front_side_visible_reflectance_at_normal_incidence": 0.081, + "back_side_visible_reflectance_at_normal_incidence": 0.081, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.84, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "CLEAR 3MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.118110236, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.837, + "front_side_solar_reflectance_at_normal_incidence": 0.075, + "back_side_solar_reflectance_at_normal_incidence": 0.075, + "visible_transmittance_at_normal_incidence": 0.898, + "front_side_visible_reflectance_at_normal_incidence": 0.081, + "back_side_visible_reflectance_at_normal_incidence": 0.081, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.84, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "CLEAR 6MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.236220472, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.775, + "front_side_solar_reflectance_at_normal_incidence": 0.071, + "back_side_solar_reflectance_at_normal_incidence": 0.071, + "visible_transmittance_at_normal_incidence": 0.881, + "front_side_visible_reflectance_at_normal_incidence": 0.08, + "back_side_visible_reflectance_at_normal_incidence": 0.08, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.84, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "COATED POLY-55", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.02007874, + "conductivity": 0.970686052, + "resistance": 1.030199206, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.32, + "front_side_solar_reflectance_at_normal_incidence": 0.582, + "back_side_solar_reflectance_at_normal_incidence": 0.593, + "visible_transmittance_at_normal_incidence": 0.551, + "front_side_visible_reflectance_at_normal_incidence": 0.336, + "back_side_visible_reflectance_at_normal_incidence": 0.375, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.046, + "back_side_infrared_hemispherical_emissivity": 0.72, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "COATED POLY-77", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.02007874, + "conductivity": 0.970686052, + "resistance": 1.030199206, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.504, + "front_side_solar_reflectance_at_normal_incidence": 0.402, + "back_side_solar_reflectance_at_normal_incidence": 0.398, + "visible_transmittance_at_normal_incidence": 0.766, + "front_side_visible_reflectance_at_normal_incidence": 0.147, + "back_side_visible_reflectance_at_normal_incidence": 0.167, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.075, + "back_side_infrared_hemispherical_emissivity": 0.72, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R0.01", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.0016, + "conductivity": 0.1596, + "resistance": 0.010025063, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R0.02", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.0032, + "conductivity": 0.1596, + "resistance": 0.020050125, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R0.10", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.016, + "conductivity": 0.1596, + "resistance": 0.100250627, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R1.35", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.216, + "conductivity": 0.1596, + "resistance": 1.353383459, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R1.41", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.2256, + "conductivity": 0.1596, + "resistance": 1.413533835, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R1.54", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.2464, + "conductivity": 0.1596, + "resistance": 1.543859649, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R10.06", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1.6096, + "conductivity": 0.1596, + "resistance": 10.08521303, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R12.55", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 2.008, + "conductivity": 0.1596, + "resistance": 12.58145363, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R12.69", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 2.0304, + "conductivity": 0.1596, + "resistance": 12.72180451, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R13.99", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 2.2384, + "conductivity": 0.1596, + "resistance": 14.02506266, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R14.14", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 2.2624, + "conductivity": 0.1596, + "resistance": 14.1754386, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R14.32", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 2.2912, + "conductivity": 0.1596, + "resistance": 14.35588972, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R14.60", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 2.336, + "conductivity": 0.1596, + "resistance": 14.63659148, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R15.54", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 2.4864, + "conductivity": 0.1596, + "resistance": 15.57894737, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R16.58", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 2.6528, + "conductivity": 0.1596, + "resistance": 16.62155388, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R16.69", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 2.6704, + "conductivity": 0.1596, + "resistance": 16.73182957, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R17.67", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 2.8272, + "conductivity": 0.1596, + "resistance": 17.71428571, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R19.63", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 3.1408, + "conductivity": 0.1596, + "resistance": 19.67919799, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R2.15", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.344, + "conductivity": 0.1596, + "resistance": 2.155388471, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R2.19", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.3504, + "conductivity": 0.1596, + "resistance": 2.195488722, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R2.85", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.456, + "conductivity": 0.1596, + "resistance": 2.857142857, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R2.89", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.4624, + "conductivity": 0.1596, + "resistance": 2.897243108, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R20.05", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 3.208, + "conductivity": 0.1596, + "resistance": 20.10025063, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R21.18", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 3.3888, + "conductivity": 0.1596, + "resistance": 21.23308271, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R21.39", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 3.4224, + "conductivity": 0.1596, + "resistance": 21.44360902, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R22.48", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 3.5968, + "conductivity": 0.1596, + "resistance": 22.53634085, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R24.86", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 3.9776, + "conductivity": 0.1596, + "resistance": 24.92230576, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R25.16", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 4.0256, + "conductivity": 0.1596, + "resistance": 25.22305764, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R28.63", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 4.5808, + "conductivity": 0.1596, + "resistance": 28.70175439, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R3.63", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.5808, + "conductivity": 0.1596, + "resistance": 3.639097744, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R3.70", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.592, + "conductivity": 0.1596, + "resistance": 3.709273183, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R34.93", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 5.5888, + "conductivity": 0.1596, + "resistance": 35.01754386, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R6.32", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1.0112, + "conductivity": 0.1596, + "resistance": 6.335839599, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R6.46", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1.0336, + "conductivity": 0.1596, + "resistance": 6.476190476, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R7.10", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1.136, + "conductivity": 0.1596, + "resistance": 7.117794486, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R7.18", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1.1488, + "conductivity": 0.1596, + "resistance": 7.197994987, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R7.39", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1.1824, + "conductivity": 0.1596, + "resistance": 7.408521303, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R8.00", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1.28, + "conductivity": 0.1596, + "resistance": 8.020050125, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R8.07", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1.2912, + "conductivity": 0.1596, + "resistance": 8.090225564, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R9.83", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1.5697, + "conductivity": 0.1596, + "resistance": 9.835213033, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Compliance Insulation R9.94", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1.5904, + "conductivity": 0.1596, + "resistance": 9.964912281, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - 100 lb/ft3 - 10 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 10, + "conductivity": 6.2496, + "resistance": 1.600102407, + "density": 100, + "specific_heat": 0.21, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - 100 lb/ft3 - 12 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 12, + "conductivity": 6.2496, + "resistance": 1.920122888, + "density": 100, + "specific_heat": 0.21, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - 100 lb/ft3 - 2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 2, + "conductivity": 6.2496, + "resistance": 0.320020481, + "density": 100, + "specific_heat": 0.21, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - 100 lb/ft3 - 4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 4, + "conductivity": 6.2496, + "resistance": 0.640040963, + "density": 100, + "specific_heat": 0.21, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - 100 lb/ft3 - 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 6, + "conductivity": 6.2496, + "resistance": 0.960061444, + "density": 100, + "specific_heat": 0.21, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - 100 lb/ft3 - 8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 8, + "conductivity": 6.2496, + "resistance": 1.280081925, + "density": 100, + "specific_heat": 0.21, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - 140 lb/ft3 - 10 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 10, + "conductivity": 13.53, + "resistance": 0.7390983, + "density": 139.78, + "specific_heat": 0.22, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - 140 lb/ft3 - 12 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 12, + "conductivity": 13.53, + "resistance": 0.88691796, + "density": 139.78, + "specific_heat": 0.22, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - 140 lb/ft3 - 2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 2, + "conductivity": 13.53, + "resistance": 0.14781966, + "density": 139.78, + "specific_heat": 0.22, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - 140 lb/ft3 - 4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 4, + "conductivity": 13.53, + "resistance": 0.29563932, + "density": 139.78, + "specific_heat": 0.22, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - 140 lb/ft3 - 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 6, + "conductivity": 13.53, + "resistance": 0.44345898, + "density": 139.78, + "specific_heat": 0.22, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - 140 lb/ft3 - 8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 8, + "conductivity": 13.53, + "resistance": 0.59127864, + "density": 139.78, + "specific_heat": 0.22, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - 80 lb/ft3 - 10 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 10, + "conductivity": 3.6804, + "resistance": 2.717095968, + "density": 79.87, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - 80 lb/ft3 - 12 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 12, + "conductivity": 3.6804, + "resistance": 3.260515161, + "density": 79.87, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - 80 lb/ft3 - 2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 2, + "conductivity": 3.6804, + "resistance": 0.543419194, + "density": 79.87, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - 80 lb/ft3 - 4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 4, + "conductivity": 3.6804, + "resistance": 1.086838387, + "density": 79.87, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - 80 lb/ft3 - 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 6, + "conductivity": 3.6804, + "resistance": 1.630257581, + "density": 79.87, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - 80 lb/ft3 - 8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 8, + "conductivity": 3.6804, + "resistance": 2.173676774, + "density": 79.87, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Part Grouted and Empty - 105 lb/ft3 - 10 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 10, + "conductivity": 4.5996, + "resistance": 2.174102096, + "density": 105, + "specific_heat": 0.14, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Part Grouted and Empty - 105 lb/ft3 - 12 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 12, + "conductivity": 5.16, + "resistance": 2.325581395, + "density": 105, + "specific_heat": 0.14, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Part Grouted and Empty - 105 lb/ft3 - 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 6, + "conductivity": 3.24, + "resistance": 1.851851852, + "density": 105, + "specific_heat": 0.15, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Part Grouted and Empty - 105 lb/ft3 - 8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 8, + "conductivity": 3.9996, + "resistance": 2.00020002, + "density": 105, + "specific_heat": 0.14, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Part Grouted and Empty - 115 lb/ft3 - 10 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 10, + "conductivity": 4.8996, + "resistance": 2.040982937, + "density": 115, + "specific_heat": 0.14, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Part Grouted and Empty - 115 lb/ft3 - 12 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 12, + "conductivity": 5.52, + "resistance": 2.173913043, + "density": 115, + "specific_heat": 0.14, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Part Grouted and Empty - 115 lb/ft3 - 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 6, + "conductivity": 3.48, + "resistance": 1.724137931, + "density": 115, + "specific_heat": 0.15, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Part Grouted and Empty - 115 lb/ft3 - 8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 8, + "conductivity": 4.2396, + "resistance": 1.886970469, + "density": 115, + "specific_heat": 0.14, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Part Grouted and Empty - 125 lb/ft3 - 10 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 10, + "conductivity": 5.1996, + "resistance": 1.923224863, + "density": 125, + "specific_heat": 0.14, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Part Grouted and Empty - 125 lb/ft3 - 12 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 12, + "conductivity": 5.88, + "resistance": 2.040816327, + "density": 125, + "specific_heat": 0.13, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Part Grouted and Empty - 125 lb/ft3 - 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 6, + "conductivity": 3.66, + "resistance": 1.639344262, + "density": 125, + "specific_heat": 0.14, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Part Grouted and Empty - 125 lb/ft3 - 8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 8, + "conductivity": 4.4796, + "resistance": 1.785873739, + "density": 125, + "specific_heat": 0.13, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Part Grouted and Insulated - 105 lb/ft3 - 10 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 10, + "conductivity": 3.3996, + "resistance": 2.941522532, + "density": 105, + "specific_heat": 0.14, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Part Grouted and Insulated - 105 lb/ft3 - 12 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 12, + "conductivity": 3.6, + "resistance": 3.333333333, + "density": 105, + "specific_heat": 0.14, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Part Grouted and Insulated - 105 lb/ft3 - 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 6, + "conductivity": 2.64, + "resistance": 2.272727273, + "density": 105, + "specific_heat": 0.15, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Part Grouted and Insulated - 105 lb/ft3 - 8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 8, + "conductivity": 2.9604, + "resistance": 2.702337522, + "density": 105, + "specific_heat": 0.14, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Part Grouted and Insulated - 115 lb/ft3 - 10 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 10, + "conductivity": 3.6996, + "resistance": 2.702994918, + "density": 115, + "specific_heat": 0.14, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Part Grouted and Insulated - 115 lb/ft3 - 12 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 12, + "conductivity": 3.96, + "resistance": 3.03030303, + "density": 115, + "specific_heat": 0.14, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Part Grouted and Insulated - 115 lb/ft3 - 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 6, + "conductivity": 2.88, + "resistance": 2.083333333, + "density": 115, + "specific_heat": 0.15, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Part Grouted and Insulated - 115 lb/ft3 - 8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 8, + "conductivity": 3.2796, + "resistance": 2.439321869, + "density": 115, + "specific_heat": 0.14, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Part Grouted and Insulated - 125 lb/ft3 - 10 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 10, + "conductivity": 4.1004, + "resistance": 2.43878646, + "density": 125, + "specific_heat": 0.14, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Part Grouted and Insulated - 125 lb/ft3 - 12 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 12, + "conductivity": 4.32, + "resistance": 2.777777778, + "density": 125, + "specific_heat": 0.13, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Part Grouted and Insulated - 125 lb/ft3 - 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 6, + "conductivity": 3.12, + "resistance": 1.923076923, + "density": 125, + "specific_heat": 0.14, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Part Grouted and Insulated - 125 lb/ft3 - 8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 8, + "conductivity": 3.5196, + "resistance": 2.272985567, + "density": 125, + "specific_heat": 0.13, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Solid Grout - 105 lb/ft3 - 10 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 10, + "conductivity": 8.4744, + "resistance": 1.180024545, + "density": 105, + "specific_heat": 0.22, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Solid Grout - 105 lb/ft3 - 12 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 12, + "conductivity": 8.5704, + "resistance": 1.40016802, + "density": 105, + "specific_heat": 0.22, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Solid Grout - 105 lb/ft3 - 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 6, + "conductivity": 8.3328, + "resistance": 0.720046083, + "density": 105, + "specific_heat": 0.21, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Solid Grout - 105 lb/ft3 - 8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 8, + "conductivity": 8.3328, + "resistance": 0.960061444, + "density": 105, + "specific_heat": 0.22, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Solid Grout - 115 lb/ft3 - 10 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 10, + "conductivity": 9.174, + "resistance": 1.090037061, + "density": 115, + "specific_heat": 0.21, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Solid Grout - 115 lb/ft3 - 12 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 12, + "conductivity": 9.2304, + "resistance": 1.300052002, + "density": 115, + "specific_heat": 0.21, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Solid Grout - 115 lb/ft3 - 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 6, + "conductivity": 10.17, + "resistance": 0.589970501, + "density": 115, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Solid Grout - 115 lb/ft3 - 8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 8, + "conductivity": 9.1224, + "resistance": 0.876962203, + "density": 115, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Solid Grout - 125 lb/ft3 - 10 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 10, + "conductivity": 10.1016, + "resistance": 0.989942187, + "density": 125, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Solid Grout - 125 lb/ft3 - 12 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 12, + "conductivity": 10.0836, + "resistance": 1.190051172, + "density": 125, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Solid Grout - 125 lb/ft3 - 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 6, + "conductivity": 10.17, + "resistance": 0.589970501, + "density": 125, + "specific_heat": 0.19, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete - Solid Grout - 125 lb/ft3 - 8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 8, + "conductivity": 10.1268, + "resistance": 0.789983015, + "density": 125, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Paver", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 0.38, + "conductivity": 4.5024, + "resistance": 0.084399431, + "density": 144, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 100% Ins. Layer - No Steel in Ins. - Ins. 1 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 13.5, + "conductivity": 1.8396, + "resistance": 7.338551859, + "density": 133.44, + "specific_heat": 0.11, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 100% Ins. Layer - No Steel in Ins. - Ins. 2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 14, + "conductivity": 1.4496, + "resistance": 9.657836645, + "density": 128.71, + "specific_heat": 0.11, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 100% Ins. Layer - No Steel in Ins. - Ins. 3 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 15, + "conductivity": 1.05, + "resistance": 14.28571429, + "density": 120.2, + "specific_heat": 0.11, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 100% Ins. Layer - No Steel in Ins. - Ins. 4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 16, + "conductivity": 0.8496, + "resistance": 18.83239171, + "density": 112.75, + "specific_heat": 0.11, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 100% Ins. Layer - No Steel in Ins. - Ins. 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 18, + "conductivity": 0.63, + "resistance": 28.57142857, + "density": 100.33, + "specific_heat": 0.11, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 100% Ins. Layer - Steel in Ins. - Ins. 1 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 13.5, + "conductivity": 2.5704, + "resistance": 5.25210084, + "density": 133.44, + "specific_heat": 0.11, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 100% Ins. Layer - Steel in Ins. - Ins. 2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 14, + "conductivity": 2.01, + "resistance": 6.965174129, + "density": 128.71, + "specific_heat": 0.11, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 100% Ins. Layer - Steel in Ins. - Ins. 3 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 15, + "conductivity": 1.4796, + "resistance": 10.1378751, + "density": 120.2, + "specific_heat": 0.11, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 100% Ins. Layer - Steel in Ins. - Ins. 4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 16, + "conductivity": 1.1904, + "resistance": 13.44086022, + "density": 112.75, + "specific_heat": 0.11, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 100% Ins. Layer - Steel in Ins. - Ins. 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 18, + "conductivity": 0.9, + "resistance": 20, + "density": 100.33, + "specific_heat": 0.11, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 80% Ins. Layer - No Steel in Ins. - Ins. 1 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 13.5, + "conductivity": 15.8604, + "resistance": 0.851176515, + "density": 133.44, + "specific_heat": 0.11, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 80% Ins. Layer - No Steel in Ins. - Ins. 2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 14, + "conductivity": 14.7504, + "resistance": 0.949126803, + "density": 128.71, + "specific_heat": 0.11, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 80% Ins. Layer - No Steel in Ins. - Ins. 3 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 15, + "conductivity": 11.9904, + "resistance": 1.251000801, + "density": 120.2, + "specific_heat": 0.12, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 80% Ins. Layer - No Steel in Ins. - Ins. 4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 16, + "conductivity": 10.3404, + "resistance": 1.547328923, + "density": 112.75, + "specific_heat": 0.12, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 80% Ins. Layer - No Steel in Ins. - Ins. 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 18, + "conductivity": 8.3604, + "resistance": 2.153007033, + "density": 100.33, + "specific_heat": 0.13, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 80% Ins. Layer - Steel in Ins. - Ins. 1 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 13.5, + "conductivity": 15.8604, + "resistance": 0.851176515, + "density": 133.44, + "specific_heat": 0.11, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 80% Ins. Layer - Steel in Ins. - Ins. 2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 14, + "conductivity": 25.1796, + "resistance": 0.556005655, + "density": 128.71, + "specific_heat": 0.11, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 80% Ins. Layer - Steel in Ins. - Ins. 3 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 15, + "conductivity": 31.5096, + "resistance": 0.476045396, + "density": 120.2, + "specific_heat": 0.12, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 80% Ins. Layer - Steel in Ins. - Ins. 4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 16, + "conductivity": 38.37, + "resistance": 0.416992442, + "density": 112.75, + "specific_heat": 0.12, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 80% Ins. Layer - Steel in Ins. - Ins. 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 18, + "conductivity": 54.0504, + "resistance": 0.333022512, + "density": 100.33, + "specific_heat": 0.13, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 90% Ins. Layer - No Steel in Ins. - Ins. 1 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 13.5, + "conductivity": 10.7904, + "resistance": 1.2511121, + "density": 133.44, + "specific_heat": 0.11, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 90% Ins. Layer - No Steel in Ins. - Ins. 2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 14, + "conductivity": 9.66, + "resistance": 1.449275362, + "density": 128.71, + "specific_heat": 0.11, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 90% Ins. Layer - No Steel in Ins. - Ins. 3 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 15, + "conductivity": 7.32, + "resistance": 2.049180328, + "density": 120.2, + "specific_heat": 0.11, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 90% Ins. Layer - No Steel in Ins. - Ins. 4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 16, + "conductivity": 6.0396, + "resistance": 2.649182065, + "density": 112.75, + "specific_heat": 0.11, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 90% Ins. Layer - No Steel in Ins. - Ins. 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 18, + "conductivity": 4.7904, + "resistance": 3.75751503, + "density": 100.33, + "specific_heat": 0.12, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 90% Ins. Layer - Steel in Ins. - Ins. 1 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 13.5, + "conductivity": 11.7396, + "resistance": 1.149954002, + "density": 133.44, + "specific_heat": 0.11, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 90% Ins. Layer - Steel in Ins. - Ins. 2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 14, + "conductivity": 9.66, + "resistance": 1.449275362, + "density": 128.71, + "specific_heat": 0.11, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 90% Ins. Layer - Steel in Ins. - Ins. 3 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 15, + "conductivity": 7.6896, + "resistance": 1.950686642, + "density": 120.2, + "specific_heat": 0.11, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 90% Ins. Layer - Steel in Ins. - Ins. 4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 16, + "conductivity": 6.5304, + "resistance": 2.450079628, + "density": 112.75, + "specific_heat": 0.11, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete Sandwich Panel - 90% Ins. Layer - Steel in Ins. - Ins. 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 18, + "conductivity": 5.0604, + "resistance": 3.557031065, + "density": 100.33, + "specific_heat": 0.12, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Concrete/Sand Aggregate - 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.01, + "conductivity": 4.29, + "resistance": 1.400932401, + "density": 116, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Continuous Ins. - Double glass with no low e coatings - No Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.27, + "conductivity": 0.9, + "resistance": 2.522222222, + "density": 29.09, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Continuous Ins. - Double glass with no low e coatings - R10 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 3.27, + "conductivity": 0.26196, + "resistance": 12.4828218, + "density": 20.44, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Continuous Ins. - Double glass with no low e coatings - R15 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 4.47, + "conductivity": 0.25296, + "resistance": 17.67077799, + "density": 15.23, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Continuous Ins. - Double glass with no low e coatings - R20 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 5.67, + "conductivity": 0.25308, + "resistance": 22.40398293, + "density": 12.22, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Continuous Ins. - Double glass with no low e coatings - R25 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.87, + "conductivity": 0.2478, + "resistance": 27.72397094, + "density": 10.26, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Continuous Ins. - Double glass with no low e coatings - R30 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 8.07, + "conductivity": 0.2484, + "resistance": 32.48792271, + "density": 8.88, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Continuous Ins. - Double glass with no low e coatings - R4 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 1.83, + "conductivity": 0.2814, + "resistance": 6.503198294, + "density": 35.69, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Continuous Ins. - Double glass with no low e coatings - R7 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.55, + "conductivity": 0.27, + "resistance": 9.444444444, + "density": 25.92, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Continuous Ins. - Single glass pane. stone. or metal pane - No Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.27, + "conductivity": 1.1796, + "resistance": 1.924381146, + "density": 29.09, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Continuous Ins. - Single glass pane. stone. or metal pane - R10 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 3.27, + "conductivity": 0.27312, + "resistance": 11.97275923, + "density": 20.44, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Continuous Ins. - Single glass pane. stone. or metal pane - R15 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 4.47, + "conductivity": 0.2628, + "resistance": 17.00913242, + "density": 15.23, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Continuous Ins. - Single glass pane. stone. or metal pane - R20 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 5.67, + "conductivity": 0.2592, + "resistance": 21.875, + "density": 12.22, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Continuous Ins. - Single glass pane. stone. or metal pane - R25 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.87, + "conductivity": 0.25512, + "resistance": 26.92850423, + "density": 10.26, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Continuous Ins. - Single glass pane. stone. or metal pane - R30 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 8.07, + "conductivity": 0.25692, + "resistance": 31.41055582, + "density": 8.88, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Continuous Ins. - Single glass pane. stone. or metal pane - R4 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 1.83, + "conductivity": 0.3096, + "resistance": 5.910852713, + "density": 35.69, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Continuous Ins. - Single glass pane. stone. or metal pane - R7 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.55, + "conductivity": 0.28476, + "resistance": 8.954909397, + "density": 25.92, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Continuous Ins. - Triple or low e glass - No Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.27, + "conductivity": 0.78, + "resistance": 2.91025641, + "density": 29.09, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Continuous Ins. - Triple or low e glass - R10 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 3.27, + "conductivity": 0.25452, + "resistance": 12.84771334, + "density": 20.44, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Continuous Ins. - Triple or low e glass - R15 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 4.47, + "conductivity": 0.24804, + "resistance": 18.02128689, + "density": 15.23, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Continuous Ins. - Triple or low e glass - R20 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 5.67, + "conductivity": 0.24696, + "resistance": 22.95918367, + "density": 12.22, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Continuous Ins. - Triple or low e glass - R25 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.87, + "conductivity": 0.2478, + "resistance": 27.72397094, + "density": 10.26, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Continuous Ins. - Triple or low e glass - R30 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 8.07, + "conductivity": 0.2484, + "resistance": 32.48792271, + "density": 8.88, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Continuous Ins. - Triple or low e glass - R4 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 1.83, + "conductivity": 0.2652, + "resistance": 6.900452489, + "density": 35.69, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Continuous Ins. - Triple or low e glass - R7 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.55, + "conductivity": 0.25752, + "resistance": 9.902143523, + "density": 25.92, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "CP02 CARPET PAD", + "material_type": "MasslessOpaqueMaterial", + "roughness": "VeryRough", + "thickness": null, + "conductivity": null, + "resistance": 1.229230374, + "density": null, + "specific_heat": null, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.8, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Douglas Fir-Larch - 1 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1, + "conductivity": 0.9804, + "resistance": 1.01999184, + "density": 34.88, + "specific_heat": 0.39, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "ECABS-2 BLEACHED 6MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.236220472, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.814, + "front_side_solar_reflectance_at_normal_incidence": 0.086, + "back_side_solar_reflectance_at_normal_incidence": 0.086, + "visible_transmittance_at_normal_incidence": 0.847, + "front_side_visible_reflectance_at_normal_incidence": 0.099, + "back_side_visible_reflectance_at_normal_incidence": 0.099, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.1, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "ECABS-2 COLORED 6MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.236220472, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.111, + "front_side_solar_reflectance_at_normal_incidence": 0.179, + "back_side_solar_reflectance_at_normal_incidence": 0.179, + "visible_transmittance_at_normal_incidence": 0.128, + "front_side_visible_reflectance_at_normal_incidence": 0.081, + "back_side_visible_reflectance_at_normal_incidence": 0.081, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.1, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "ECREF-1 COLORED 6MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.236220472, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.099, + "front_side_solar_reflectance_at_normal_incidence": 0.219, + "back_side_solar_reflectance_at_normal_incidence": 0.219, + "visible_transmittance_at_normal_incidence": 0.155, + "front_side_visible_reflectance_at_normal_incidence": 0.073, + "back_side_visible_reflectance_at_normal_incidence": 0.073, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.84, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "ECREF-2 BLEACHED 6MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.236220472, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.694, + "front_side_solar_reflectance_at_normal_incidence": 0.168, + "back_side_solar_reflectance_at_normal_incidence": 0.168, + "visible_transmittance_at_normal_incidence": 0.818, + "front_side_visible_reflectance_at_normal_incidence": 0.11, + "back_side_visible_reflectance_at_normal_incidence": 0.11, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.1, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "ECREF-2 COLORED 6MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.236220472, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.099, + "front_side_solar_reflectance_at_normal_incidence": 0.219, + "back_side_solar_reflectance_at_normal_incidence": 0.219, + "visible_transmittance_at_normal_incidence": 0.155, + "front_side_visible_reflectance_at_normal_incidence": 0.073, + "back_side_visible_reflectance_at_normal_incidence": 0.073, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.1, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded perlite - organic bonded - 1 1/2 in. R4.2", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1.5, + "conductivity": 0.36, + "resistance": 4.166666667, + "density": 1, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded perlite - organic bonded - 1 in. R2.8", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1, + "conductivity": 0.36, + "resistance": 2.777777778, + "density": 1, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded perlite - organic bonded - 2 in. R5.6", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 2, + "conductivity": 0.36, + "resistance": 5.555555556, + "density": 1, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded perlite - organic bonded - 3 in. R8.3", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 3, + "conductivity": 0.36, + "resistance": 8.333333333, + "density": 1, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded perlite - organic bonded - 3/4 in. R2.1", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.75, + "conductivity": 0.36, + "resistance": 2.083333333, + "density": 1, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded perlite - organic bonded - 4 in. R11", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 4, + "conductivity": 0.36, + "resistance": 11.11111111, + "density": 1, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded perlite - organic bonded - 6 in. R17", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 6, + "conductivity": 0.36, + "resistance": 16.66666667, + "density": 1, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded Polystyrene - EPS - 1 1/2 in. R6.3", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1.5, + "conductivity": 0.24, + "resistance": 6.25, + "density": 1.2, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded Polystyrene - EPS - 1 1/4 in. R5.2", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1.25, + "conductivity": 0.24, + "resistance": 5.208333333, + "density": 1.2, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded Polystyrene - EPS - 1 15/16 in. R8.1", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1.94, + "conductivity": 0.24, + "resistance": 8.083333333, + "density": 1.2, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded Polystyrene - EPS - 1 3/4 in. R7.3", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1.75, + "conductivity": 0.24, + "resistance": 7.291666667, + "density": 1.2, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded Polystyrene - EPS - 1 7/8 in. R8.0", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1.92, + "conductivity": 0.24, + "resistance": 8, + "density": 1.2, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded Polystyrene - EPS - 1 in. R4.2", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1, + "conductivity": 0.24, + "resistance": 4.166666667, + "density": 1.2, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded Polystyrene - EPS - 1/2 in. R2.1", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.5, + "conductivity": 0.24, + "resistance": 2.083333333, + "density": 1.2, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded Polystyrene - EPS - 1/4 in. R1.0", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.25, + "conductivity": 0.24, + "resistance": 1.041666667, + "density": 1.2, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded Polystyrene - EPS - 2 2/5 in. R10", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 2.4, + "conductivity": 0.24, + "resistance": 10, + "density": 1.2, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded Polystyrene - EPS - 2 7/16 in. R10", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 2.43, + "conductivity": 0.24, + "resistance": 10.125, + "density": 1.2, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded Polystyrene - EPS - 2 in. R8.3", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 2, + "conductivity": 0.24, + "resistance": 8.333333333, + "density": 1.2, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded Polystyrene - EPS - 3 1/2 in. R15", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 3.5, + "conductivity": 0.24, + "resistance": 14.58333333, + "density": 1.2, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded Polystyrene - EPS - 3 1/3 in. R14", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 3.35, + "conductivity": 0.24, + "resistance": 13.95833333, + "density": 1.2, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded Polystyrene - EPS - 3 2/5 in. R14", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 3.39, + "conductivity": 0.24, + "resistance": 14.125, + "density": 1.2, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded Polystyrene - EPS - 3 in. R13", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 3.01, + "conductivity": 0.24, + "resistance": 12.54166667, + "density": 1.2, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded Polystyrene - EPS - 3/4 in. R3.1", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.75, + "conductivity": 0.24, + "resistance": 3.125, + "density": 1.2, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded Polystyrene - EPS - 4 1/16 in. R17", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 4.05, + "conductivity": 0.24, + "resistance": 16.875, + "density": 1.2, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded Polystyrene - EPS - 4 7/10 in. R20", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 4.71, + "conductivity": 0.24, + "resistance": 19.625, + "density": 1.2, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded Polystyrene - EPS - 5 19/20 in. R25", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 5.96, + "conductivity": 0.24, + "resistance": 24.83333333, + "density": 1.2, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded Polystyrene - EPS - 5 2/5 in. R22", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 5.2, + "conductivity": 0.24, + "resistance": 21.66666667, + "density": 1.2, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded Polystyrene - EPS - 6 1/10 in. R25", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 6.11, + "conductivity": 0.24, + "resistance": 25.45833333, + "density": 1.2, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded Polystyrene - EPS - 6 7/8 in. R29", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 6.87, + "conductivity": 0.24, + "resistance": 28.625, + "density": 1.2, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded Polystyrene - EPS - 8 3/5 in. R35", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 8.38, + "conductivity": 0.24, + "resistance": 34.91666667, + "density": 1.2, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded Polyurethane - 1 1/4 in. R7.8", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1.25, + "conductivity": 0.1596, + "resistance": 7.832080201, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded Polyurethane - 1 in. R6.3", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1, + "conductivity": 0.1596, + "resistance": 6.26566416, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded Polyurethane - 1/2 in. R3.1", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.5, + "conductivity": 0.1596, + "resistance": 3.13283208, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded Polyurethane - 2 in. R12.6", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 2, + "conductivity": 0.1596, + "resistance": 12.53132832, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Expanded Polyurethane - 3/4 in. R4.7", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.75, + "conductivity": 0.1596, + "resistance": 4.69924812, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Extruded Polystyrene - XPS - 1 1/2 in. R7.50", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1.5, + "conductivity": 0.200000004, + "resistance": 7.49999985, + "density": 1.3, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Extruded Polystyrene - XPS - 1 1/4 in. R6.25", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1.25, + "conductivity": 0.200000004, + "resistance": 6.249999875, + "density": 1.3, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Extruded Polystyrene - XPS - 1 3/4 in. R8.75", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1.75, + "conductivity": 0.200000004, + "resistance": 8.749999825, + "density": 1.3, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Extruded Polystyrene - XPS - 1 7/8 in. R9.37", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1.88, + "conductivity": 0.200000004, + "resistance": 9.399999812, + "density": 1.3, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Extruded Polystyrene - XPS - 1 in. R5.00", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1, + "conductivity": 0.200000004, + "resistance": 4.9999999, + "density": 1.3, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Extruded Polystyrene - XPS - 1/2 in. R2.50", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.5, + "conductivity": 0.200000004, + "resistance": 2.49999995, + "density": 1.3, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Extruded Polystyrene - XPS - 1/4 in. R1.25", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.25, + "conductivity": 0.200000004, + "resistance": 1.249999975, + "density": 1.3, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Extruded Polystyrene - XPS - 2 1/2 in. R12.50", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 2.5, + "conductivity": 0.200000004, + "resistance": 12.49999975, + "density": 1.3, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Extruded Polystyrene - XPS - 2 in. R10.00", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 2, + "conductivity": 0.200000004, + "resistance": 9.9999998, + "density": 1.3, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Extruded Polystyrene - XPS - 3 1/2 in. R17.50", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 3.5, + "conductivity": 0.200000004, + "resistance": 17.49999965, + "density": 1.3, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Extruded Polystyrene - XPS - 3 in. R15.00", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 3, + "conductivity": 0.200000004, + "resistance": 14.9999997, + "density": 1.3, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Extruded Polystyrene - XPS - 3/4 in. R3.75", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.75, + "conductivity": 0.200000004, + "resistance": 3.749999925, + "density": 1.3, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Extruded Polystyrene - XPS - 4 1/2 in. R22.50", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 4.5, + "conductivity": 0.200000004, + "resistance": 22.49999955, + "density": 1.3, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Extruded Polystyrene - XPS - 4 in. R20.00", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 4, + "conductivity": 0.200000004, + "resistance": 19.9999996, + "density": 1.3, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Extruded Polystyrene - XPS - 5 1/2 in. R27.50", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 5.5, + "conductivity": 0.200000004, + "resistance": 27.49999945, + "density": 1.3, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Extruded Polystyrene - XPS - 5 in. R25.00", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 5, + "conductivity": 0.200000004, + "resistance": 24.9999995, + "density": 1.3, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Extruded Polystyrene - XPS - 6 1/2 in. R32.50", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 6.5, + "conductivity": 0.200000004, + "resistance": 32.49999935, + "density": 1.3, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Extruded Polystyrene - XPS - 6 in. R30.00", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 6, + "conductivity": 0.200000004, + "resistance": 29.9999994, + "density": 1.3, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Extruded Polystyrene - XPS - 8 1/2 in. R42.50", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 8.5, + "conductivity": 0.200000004, + "resistance": 42.49999915, + "density": 1.3, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Extruded Polystyrene - XPS - 8 in. R40.00", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 8, + "conductivity": 0.200000004, + "resistance": 39.9999992, + "density": 1.3, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "F04 Wall air space resistance", + "material_type": "AirGap", + "roughness": null, + "thickness": null, + "conductivity": 46.22314532, + "resistance": 0.021634183, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "F05 Ceiling air space resistance", + "material_type": "AirGap", + "roughness": null, + "thickness": null, + "conductivity": 38.51928777, + "resistance": 0.02596102, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "F08 Metal surface", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.031496063, + "conductivity": 313.947603, + "resistance": 0.000100323, + "density": 488.4363635, + "specific_heat": 0.119422948, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "F16 Acoustic tile", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.751968504, + "conductivity": 0.416008308, + "resistance": 1.807580497, + "density": 22.97348949, + "specific_heat": 0.140919079, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.3, + "visible_absorptance": 0.3, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fiber cement board - 63 lb/ft3 - 1/3 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.31, + "conductivity": 1.2996, + "resistance": 0.238534934, + "density": 63, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fiber cement board - 88 lb/ft3 - 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.47, + "conductivity": 1.7004, + "resistance": 0.276405552, + "density": 88, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fiber cement board - 88 lb/ft3 - 1/3 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.31, + "conductivity": 1.7004, + "resistance": 0.182310045, + "density": 88, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fiberboard sheathing - 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.5, + "conductivity": 0.4896, + "resistance": 1.02124183, + "density": 24.96, + "specific_heat": 0.31, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 2.00/0.40/0.31", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.35, + "solar_heat_gain_coefficient": 0.4, + "visible_transmittance": 0.31, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 2.00/0.45/0.35", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.35, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": 0.35, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 2.30/0.40/0.31", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.4, + "solar_heat_gain_coefficient": 0.4, + "visible_transmittance": 0.31, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 2.56/0.45/0.35", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.45, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": 0.35, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 2.62/0.30/0.21", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.459978667, + "solar_heat_gain_coefficient": 0.3, + "visible_transmittance": 0.21, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 2.67/0.30/0.21", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.469978203, + "solar_heat_gain_coefficient": 0.49, + "visible_transmittance": 0.38, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 2.96/0.39/0.31", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.519975884, + "solar_heat_gain_coefficient": 0.39, + "visible_transmittance": 0.31, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 2.96/0.49/0.41", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.519975884, + "solar_heat_gain_coefficient": 0.49, + "visible_transmittance": 0.41, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 2.96/0.62/0.54", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.519975884, + "solar_heat_gain_coefficient": 0.62, + "visible_transmittance": 0.54, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 3.12/0.40/0.31", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.55, + "solar_heat_gain_coefficient": 0.4, + "visible_transmittance": 0.31, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 3.24/0.25/0.16", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.569973565, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": 0.16, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 3.24/0.39/0.31", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.569973565, + "solar_heat_gain_coefficient": 0.39, + "visible_transmittance": 0.31, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 3.24/0.49/0.41", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.569973565, + "solar_heat_gain_coefficient": 0.49, + "visible_transmittance": 0.41, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 3.35/0.36/0.27", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.589972638, + "solar_heat_gain_coefficient": 0.36, + "visible_transmittance": 0.27, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 3.35/0.39/0.31", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.589972638, + "solar_heat_gain_coefficient": 0.39, + "visible_transmittance": 0.31, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 3.53/0.41/0.32", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.619971246, + "solar_heat_gain_coefficient": 0.41, + "visible_transmittance": 0.32, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 3.69/0.25/0.16", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.65, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": 0.16, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 3.69/0.70/0.60", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.65, + "solar_heat_gain_coefficient": 0.7, + "visible_transmittance": 0.6, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 3.81/0.39/0.27", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.519975884, + "solar_heat_gain_coefficient": 0.39, + "visible_transmittance": 0.27, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 3.81/0.49/0.38", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.519975884, + "solar_heat_gain_coefficient": 0.49, + "visible_transmittance": 0.38, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 4.09/0.26/0.13", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.719966609, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": 0.13, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 4.09/0.36/0.23", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.719966609, + "solar_heat_gain_coefficient": 0.36, + "visible_transmittance": 0.23, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 4.09/0.39/0.25", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.719966609, + "solar_heat_gain_coefficient": 0.39, + "visible_transmittance": 0.25, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 4.26/0.25/0.16", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.75, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": 0.16, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 5.84/0.25/0.11", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.028483473, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": 0.11, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 5.84/0.39/0.22", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.028483473, + "solar_heat_gain_coefficient": 0.39, + "visible_transmittance": 0.22, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 5.84/0.44/0.27", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.028483473, + "solar_heat_gain_coefficient": 0.44, + "visible_transmittance": 0.27, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 5.84/0.54/0.38", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.028483473, + "solar_heat_gain_coefficient": 0.54, + "visible_transmittance": 0.38, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 5.84/0.61/0.47", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.028483473, + "solar_heat_gain_coefficient": 0.61, + "visible_transmittance": 0.47, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Fixed Window 5.84/0.70/0.60", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.028483473, + "solar_heat_gain_coefficient": 0.7, + "visible_transmittance": 0.6, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "G01 13mm gypsum board", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.5, + "conductivity": 1.10957004, + "resistance": 0.450625001, + "density": 49.9424, + "specific_heat": 0.260516252, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.5, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "G01a 19mm gypsum board", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.748031496, + "conductivity": 1.109355488, + "resistance": 0.674293772, + "density": 49.94236846, + "specific_heat": 0.260342027, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.4, + "visible_absorptance": 0.4, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "G05 25mm wood", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1, + "conductivity": 1.04002077, + "resistance": 0.961519259, + "density": 37.95620003, + "specific_heat": 0.389318812, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.5, + "visible_absorptance": 0.5, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Gap_1_W_0_0018", + "material_type": "Gas", + "roughness": null, + "thickness": 0.070866142, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": "Air", + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Gap_1_W_0_0024", + "material_type": "Gas", + "roughness": null, + "thickness": 0.094488189, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": "Air", + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Gap_1_W_0_0025", + "material_type": "Gas", + "roughness": null, + "thickness": 0.098425197, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": "Air", + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Gap_1_W_0_0032", + "material_type": "Gas", + "roughness": null, + "thickness": 0.125984252, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": "Air", + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Gap_1_W_0_0038", + "material_type": "Gas", + "roughness": null, + "thickness": 0.149606299, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": "Air", + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Gap_1_W_0_0042", + "material_type": "Gas", + "roughness": null, + "thickness": 0.165354331, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": "Air", + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Gap_1_W_0_0043", + "material_type": "Gas", + "roughness": null, + "thickness": 0.169291339, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": "Air", + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Glass fiber batt - 10 in. R30 (CEC Default)", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 10, + "conductivity": 0.3336, + "resistance": 29.97601918, + "density": 0.7, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Glass fiber batt - 12 in. R38 (CEC Default)", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 12, + "conductivity": 0.3156, + "resistance": 38.02281369, + "density": 0.7, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Glass fiber batt - 3 1/2 in. R11 (CEC Default)", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 3.5, + "conductivity": 0.318, + "resistance": 11.00628931, + "density": 0.7, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Glass fiber batt - 3 1/2 in. R13 (CEC Default)", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 3.5, + "conductivity": 0.2688, + "resistance": 13.02083333, + "density": 0.7, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Glass fiber batt - 3 1/2 in. R15 (CEC Default)", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 3.5, + "conductivity": 0.2328, + "resistance": 15.03436426, + "density": 0.7, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Glass fiber batt - 4 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 4.5, + "conductivity": 0.3, + "resistance": 15, + "density": 0.7, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Glass fiber batt - 4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 4, + "conductivity": 0.3, + "resistance": 13.33333333, + "density": 0.7, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Glass fiber batt - 5 1/2 in. R19 (CEC Default)", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 5.5, + "conductivity": 0.306, + "resistance": 17.97385621, + "density": 0.7, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Glass fiber batt - 5 1/2 in. R21 (CEC Default)", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 5.5, + "conductivity": 0.2616, + "resistance": 21.02446483, + "density": 0.7, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Glass fiber batt - 5 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 5, + "conductivity": 0.3, + "resistance": 16.66666667, + "density": 0.7, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Glass fiber batt - 6 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 6.5, + "conductivity": 0.3, + "resistance": 21.66666667, + "density": 0.7, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Glass fiber batt - 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 6, + "conductivity": 0.3, + "resistance": 20, + "density": 0.7, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Glass fiber batt - 7 1/4 in. R25 (CEC Default)", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 7.25, + "conductivity": 0.3024, + "resistance": 23.97486772, + "density": 0.7, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Glass fiber batt - 7 1/4 in. R30 (CEC Default)", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 7.25, + "conductivity": 0.2904, + "resistance": 24.96556474, + "density": 0.7, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Glass fiber batt - 8 1/4 in. R30C (CEC Default)", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 8.25, + "conductivity": 0.2748, + "resistance": 30.02183406, + "density": 0.7, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Glass_2010F_LayerAvg", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.087007874, + "conductivity": 6.933471799, + "resistance": 0.144227889, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.434294, + "front_side_solar_reflectance_at_normal_incidence": 0.4183747, + "back_side_solar_reflectance_at_normal_incidence": 0.3410654, + "visible_transmittance_at_normal_incidence": 0.797579, + "front_side_visible_reflectance_at_normal_incidence": 0.043577, + "back_side_visible_reflectance_at_normal_incidence": 0.056031, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.042274, + "back_side_infrared_hemispherical_emissivity": 0.84, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "Glass_2022F_LayerAvg", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.153543307, + "conductivity": 6.933471799, + "resistance": 0.144227889, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.355897, + "front_side_solar_reflectance_at_normal_incidence": 0.3940945, + "back_side_solar_reflectance_at_normal_incidence": 0.2656452, + "visible_transmittance_at_normal_incidence": 0.677694, + "front_side_visible_reflectance_at_normal_incidence": 0.042734, + "back_side_visible_reflectance_at_normal_incidence": 0.05547, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.046, + "back_side_infrared_hemispherical_emissivity": 0.84, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "Glass_2027F_LayerAvg", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.157480315, + "conductivity": 6.933471799, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.369744, + "front_side_solar_reflectance_at_normal_incidence": 0.4700695, + "back_side_solar_reflectance_at_normal_incidence": 0.340935, + "visible_transmittance_at_normal_incidence": 0.765222, + "front_side_visible_reflectance_at_normal_incidence": 0.0546, + "back_side_visible_reflectance_at_normal_incidence": 0.073741, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.03675, + "back_side_infrared_hemispherical_emissivity": 0.84, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "Glass_2052_LayerAvg", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.329527559, + "conductivity": 6.933471799, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.507767, + "front_side_solar_reflectance_at_normal_incidence": 0.05422805, + "back_side_solar_reflectance_at_normal_incidence": 0.05449309, + "visible_transmittance_at_normal_incidence": 0.586833, + "front_side_visible_reflectance_at_normal_incidence": 0.05805, + "back_side_visible_reflectance_at_normal_incidence": 0.058397, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.84, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "Glass_2175_LayerAvg", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.338582677, + "conductivity": 6.933471799, + "resistance": 0.144227889, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.167758, + "front_side_solar_reflectance_at_normal_incidence": 0.2176064, + "back_side_solar_reflectance_at_normal_incidence": 0.4379779, + "visible_transmittance_at_normal_incidence": 0.416044, + "front_side_visible_reflectance_at_normal_incidence": 0.078729, + "back_side_visible_reflectance_at_normal_incidence": 0.10654, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.84, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "GREEN 3MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.118110236, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.635, + "front_side_solar_reflectance_at_normal_incidence": 0.063, + "back_side_solar_reflectance_at_normal_incidence": 0.063, + "visible_transmittance_at_normal_incidence": 0.822, + "front_side_visible_reflectance_at_normal_incidence": 0.075, + "back_side_visible_reflectance_at_normal_incidence": 0.075, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.84, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "GREEN 6MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.236220472, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.487, + "front_side_solar_reflectance_at_normal_incidence": 0.056, + "back_side_solar_reflectance_at_normal_incidence": 0.056, + "visible_transmittance_at_normal_incidence": 0.749, + "front_side_visible_reflectance_at_normal_incidence": 0.07, + "back_side_visible_reflectance_at_normal_incidence": 0.07, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.84, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "GREY 6MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.236220472, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.455, + "front_side_solar_reflectance_at_normal_incidence": 0.053, + "back_side_solar_reflectance_at_normal_incidence": 0.053, + "visible_transmittance_at_normal_incidence": 0.431, + "front_side_visible_reflectance_at_normal_incidence": 0.052, + "back_side_visible_reflectance_at_normal_incidence": 0.052, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.84, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "Ground_Floor_R11_T2013", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 1.74123, + "conductivity": 0.15963, + "resistance": 10.91, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.8, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Ground_Floor_R17_T2013", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.71324, + "conductivity": 0.15963, + "resistance": 17.66, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.8, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Ground_Floor_R22_T2013", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 3.51125, + "conductivity": 0.15963, + "resistance": 22.47, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.8, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Gypsum Board - 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.5, + "conductivity": 1.10004, + "resistance": 0.454528926, + "density": 40, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Gypsum Board - 1/2 in. CBES", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.5, + "conductivity": 1.1101, + "resistance": null, + "density": 40, + "specific_heat": 0.27, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.8, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Gypsum Board - 3/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.75, + "conductivity": 1.10004, + "resistance": 0.681793389, + "density": 40, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Gypsum Board - 3/8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.38, + "conductivity": 1.10004, + "resistance": 0.345441984, + "density": 40, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Gypsum Board - 5/8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.63, + "conductivity": 1.10004, + "resistance": 0.572706447, + "density": 40, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Gypsum Or Plaster Board - 3/8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.374015748, + "conductivity": 4.021413643, + "resistance": 0.093006037, + "density": 49.94236846, + "specific_heat": 0.260342027, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Gypsum partition block - 3 cells - 4 in. x 12 in. x 30 in. - 4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 4, + "conductivity": 2.4, + "resistance": 1.666666667, + "density": 53.1, + "specific_heat": 0.19, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Gypsum partition block - 4 cells - 3 in. x 12 in. x 30 in. - 3 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 3, + "conductivity": 2.22, + "resistance": 1.351351351, + "density": 53.1, + "specific_heat": 0.19, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Gypsum partition block - solid - 3 in. x 12 in. x 30 in. - 3 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 3, + "conductivity": 2.3796, + "resistance": 1.260716087, + "density": 62.4, + "specific_heat": 0.19, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Gypsum plaster - 80 lb/ft3 - 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.5, + "conductivity": 3.2004, + "resistance": 0.156230471, + "density": 80, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Gypsum plaster - 80 lb/ft3 - 5/8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.63, + "conductivity": 3.2004, + "resistance": 0.196850394, + "density": 80, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Gypsum plaster - on metal lath 70 lb/ft3 - 3/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.75, + "conductivity": 2.6004, + "resistance": 0.288417167, + "density": 70, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Gypsum plaster - on metal lath 80 lb/ft3 - 3/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.75, + "conductivity": 3.2004, + "resistance": 0.234345707, + "density": 80, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Hard Board - 3/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.75, + "conductivity": 0.72, + "resistance": 1.041666667, + "density": 50, + "specific_heat": 0.31, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Hardboard - HDF - 50 lb/ft3 - 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.5, + "conductivity": 0.7296, + "resistance": 0.685307018, + "density": 50, + "specific_heat": 0.31, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Hardboard - HDF - 50 lb/ft3 - 3/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.75, + "conductivity": 0.7296, + "resistance": 1.027960526, + "density": 50, + "specific_heat": 0.31, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Hardboard - HDF - 50 lb/ft3 - 3/8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.38, + "conductivity": 0.7296, + "resistance": 0.520833333, + "density": 50, + "specific_heat": 0.31, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Hardboard - HDF - 50 lb/ft3 - 5/8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.63, + "conductivity": 0.7296, + "resistance": 0.863, + "density": 50, + "specific_heat": 0.31, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Hardwood - 1 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1, + "conductivity": 1.1604, + "resistance": 0.861771803, + "density": 42.43, + "specific_heat": 0.39, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Hardwood - 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.5, + "conductivity": 1.1604, + "resistance": 0.430885901, + "density": 42.43, + "specific_heat": 0.39, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Hardwood - 3/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.75, + "conductivity": 1.1604, + "resistance": 0.646328852, + "density": 42.43, + "specific_heat": 0.39, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "HB Part. Brd - 3/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.75, + "conductivity": 1.17996, + "resistance": 0.635614767, + "density": 50, + "specific_heat": 0.31, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "HW CONCRETE", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 4, + "conductivity": 9.09153953, + "resistance": 0.439969489, + "density": 139.83872, + "specific_heat": 0.2, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "HW CONCRETE 8 in", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 8, + "conductivity": 9.09153953, + "resistance": 0.879938978, + "density": 139.83872, + "specific_heat": 0.2, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "I01 25mm insulation board", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 1, + "conductivity": 0.208004154, + "resistance": 4.807596295, + "density": 2.684402305, + "specific_heat": 0.289003535, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.6, + "visible_absorptance": 0.6, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "I02 50mm insulation board", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 2, + "conductivity": 0.208004154, + "resistance": 9.615192591, + "density": 2.684402305, + "specific_heat": 0.289003535, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.6, + "visible_absorptance": 0.6, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "IEAD NonRes Roof Insulation-1.76", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 2.912618228, + "conductivity": 0.339740118, + "resistance": 8.573077103, + "density": 16.54340955, + "specific_heat": 0.199866246, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "IEAD Roof Insulation R-3.47 IP", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 1.178836998, + "conductivity": 0.339740118, + "resistance": 3.469819827, + "density": 16.54340955, + "specific_heat": 0.199866246, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Insulating Concrete Forms - 1 1/2 in. Polyurethane Ins. each side - concrete 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 9, + "conductivity": 0.4704, + "resistance": 19.13265306, + "density": 100.33, + "specific_heat": 0.23, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Insulating Concrete Forms - 1 1/2 in. Polyurethane Ins. each side - concrete 8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 11, + "conductivity": 0.57, + "resistance": 19.29824561, + "density": 109.36, + "specific_heat": 0.22, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Insulating Concrete Forms - 2 1/2 in. EPS Ins. each side - concrete 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 11, + "conductivity": 0.51648, + "resistance": 21.29801735, + "density": 76.81, + "specific_heat": 0.23, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Insulating Concrete Forms - 2 1/2 in. EPS Ins. each side - concrete 8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 13, + "conductivity": 0.60612, + "resistance": 21.44789811, + "density": 86.54, + "specific_heat": 0.22, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Insulating Concrete Forms - 2 in. EPS Ins. each side - concrete 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 10, + "conductivity": 0.6096, + "resistance": 16.40419948, + "density": 90.4, + "specific_heat": 0.23, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Insulating Concrete Forms - 2 in. EPS Ins. each side - concrete 8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 12, + "conductivity": 0.72, + "resistance": 16.66666667, + "density": 100.33, + "specific_heat": 0.22, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Insulating Concrete Forms - 2 in. Polyurethane Ins. each side - concrete 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 10, + "conductivity": 0.4404, + "resistance": 22.70663034, + "density": 90.4, + "specific_heat": 0.23, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Insulating Concrete Forms - 2 in. Polyurethane Ins. each side - concrete 8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 12, + "conductivity": 0.5196, + "resistance": 23.09468822, + "density": 100.33, + "specific_heat": 0.22, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Insulating Concrete Forms - 2 in. XPS Ins. each side - concrete 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 10, + "conductivity": 0.4704, + "resistance": 21.2585034, + "density": 90.4, + "specific_heat": 0.23, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Insulating Concrete Forms - 2 in. XPS Ins. each side - concrete 8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 12, + "conductivity": 0.57, + "resistance": 21.05263158, + "density": 100.33, + "specific_heat": 0.22, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Insulating Concrete Forms - 3 in. EPS Ins. each side - concrete 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 12, + "conductivity": 0.5004, + "resistance": 23.98081535, + "density": 75.5, + "specific_heat": 0.23, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Insulating Concrete Forms - 3 in. EPS Ins. each side - concrete 8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 14, + "conductivity": 0.57, + "resistance": 24.56140351, + "density": 86.14, + "specific_heat": 0.22, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Insulating Concrete Forms - 3 in. XPS Ins. each side - concrete 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 12, + "conductivity": 0.39, + "resistance": 30.76923077, + "density": 75.5, + "specific_heat": 0.23, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Insulating Concrete Forms - 3 in. XPS Ins. each side - concrete 8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 14, + "conductivity": 0.45, + "resistance": 31.11111111, + "density": 86.14, + "specific_heat": 0.22, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Insulating Concrete Forms - 4 1/2 in. Polyurethane Ins. each side - concrete 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 15, + "conductivity": 0.3504, + "resistance": 42.80821918, + "density": 60.6, + "specific_heat": 0.23, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Insulating Concrete Forms - 4 1/2 in. Polyurethane Ins. each side - concrete 8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 17, + "conductivity": 0.3996, + "resistance": 42.54254254, + "density": 71.12, + "specific_heat": 0.22, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Insulating Concrete Forms - 4 in. EPS Ins. each side - concrete 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 14, + "conductivity": 0.4296, + "resistance": 32.58845438, + "density": 64.86, + "specific_heat": 0.23, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Insulating Concrete Forms - 4 in. EPS Ins. each side - concrete 8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 16, + "conductivity": 0.5004, + "resistance": 31.97442046, + "density": 75.5, + "specific_heat": 0.22, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Insulating Concrete Forms - 4 in. XPS Ins. each side - concrete 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 14, + "conductivity": 0.3504, + "resistance": 39.9543379, + "density": 64.86, + "specific_heat": 0.23, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Insulating Concrete Forms - 4 in. XPS Ins. each side - concrete 8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 16, + "conductivity": 0.39, + "resistance": 41.02564103, + "density": 75.5, + "specific_heat": 0.22, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Insulation 1m", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 39.37, + "conductivity": 0.13876, + "resistance": null, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.8, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Interior Wall Addi Insul", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 1e-06, + "conductivity": 0.299941999, + "resistance": 3.33e-06, + "density": 1.399999086, + "specific_heat": 0.199866248, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Light Roof - 2/5 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "VeryRough", + "thickness": 0.2, + "conductivity": 2.4012, + "resistance": 0.083291687, + "density": 120, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Linoleum/cork tile - 1/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 0.25, + "conductivity": 0.51, + "resistance": 0.490196078, + "density": 29, + "specific_heat": 0.45, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "LoE CLEAR 6MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.236220472, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.6, + "front_side_solar_reflectance_at_normal_incidence": 0.17, + "back_side_solar_reflectance_at_normal_incidence": 0.22, + "visible_transmittance_at_normal_incidence": 0.84, + "front_side_visible_reflectance_at_normal_incidence": 0.055, + "back_side_visible_reflectance_at_normal_incidence": 0.078, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.1, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "LoE SPEC SEL CLEAR 3MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.118110236, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.45, + "front_side_solar_reflectance_at_normal_incidence": 0.34, + "back_side_solar_reflectance_at_normal_incidence": 0.37, + "visible_transmittance_at_normal_incidence": 0.78, + "front_side_visible_reflectance_at_normal_incidence": 0.07, + "back_side_visible_reflectance_at_normal_incidence": 0.06, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.03, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "LoE SPEC SEL CLEAR 6MM Rev", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.236220472, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.43, + "front_side_solar_reflectance_at_normal_incidence": 0.42, + "back_side_solar_reflectance_at_normal_incidence": 0.3, + "visible_transmittance_at_normal_incidence": 0.77, + "front_side_visible_reflectance_at_normal_incidence": 0.06, + "back_side_visible_reflectance_at_normal_incidence": 0.07, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.03, + "back_side_infrared_hemispherical_emissivity": 0.84, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "LoE SPEC SEL TINT 6MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.236220472, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.26, + "front_side_solar_reflectance_at_normal_incidence": 0.14, + "back_side_solar_reflectance_at_normal_incidence": 0.41, + "visible_transmittance_at_normal_incidence": 0.46, + "front_side_visible_reflectance_at_normal_incidence": 0.06, + "back_side_visible_reflectance_at_normal_incidence": 0.04, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.03, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "LoE TINT 6MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.236220472, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.36, + "front_side_solar_reflectance_at_normal_incidence": 0.093, + "back_side_solar_reflectance_at_normal_incidence": 0.2, + "visible_transmittance_at_normal_incidence": 0.5, + "front_side_visible_reflectance_at_normal_incidence": 0.035, + "back_side_visible_reflectance_at_normal_incidence": 0.054, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.1, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "Loose fill - Mineral fiber - 2 lb/ft3 - 13 3/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 13.75, + "conductivity": 0.336, + "resistance": 40.92261905, + "density": 2, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Loose fill - Mineral fiber - 2 lb/ft3 - 4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 4, + "conductivity": 0.336, + "resistance": 11.9047619, + "density": 2, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Loose fill - Mineral fiber - 2 lb/ft3 - 6 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 6.5, + "conductivity": 0.336, + "resistance": 19.3452381, + "density": 2, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Loose fill - Mineral fiber - 2 lb/ft3 - 7 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 7.5, + "conductivity": 0.336, + "resistance": 22.32142857, + "density": 2, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Loose fill - Mineral fiber - 2 lb/ft3 - 8 1/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 8.25, + "conductivity": 0.336, + "resistance": 24.55357143, + "density": 2, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Loose fill - Mineral fiber - closed sidewalls - 3 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 3.5, + "conductivity": 0.336, + "resistance": 10.41666667, + "density": 2, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "M01 100mm brick", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 4, + "conductivity": 6.170789901, + "resistance": 0.648215231, + "density": 119.8616843, + "specific_heat": 0.188688258, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "M11 100mm lightweight concrete", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 4, + "conductivity": 3.674740053, + "resistance": 1.088512369, + "density": 79.90778954, + "specific_heat": 0.200630553, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.5, + "visible_absorptance": 0.5, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "M15 200mm heavyweight concrete", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 8, + "conductivity": 13.52027001, + "resistance": 0.591704159, + "density": 139.8386317, + "specific_heat": 0.214961307, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.5, + "visible_absorptance": 0.5, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Maple - 1 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1, + "conductivity": 1.14, + "resistance": 0.877192982, + "density": 41.87, + "specific_heat": 0.39, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Mass NonRes Wall Insulation-0.43", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 0.017196119, + "conductivity": 0.339740118, + "resistance": 0.050615509, + "density": 16.54340955, + "specific_heat": 0.199866246, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Mass Wall Insulation R-4.23 IP", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 1.438471204, + "conductivity": 0.339740118, + "resistance": 4.234033978, + "density": 16.54340955, + "specific_heat": 0.199866246, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Mastic asphalt (heavy - 20% grit) - 1 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "VeryRough", + "thickness": 1, + "conductivity": 1.2996, + "resistance": 0.769467528, + "density": 59, + "specific_heat": 0.22, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "MAT-CC05 4 HW CONCRETE", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 4, + "conductivity": 9.089781528, + "resistance": 0.440054581, + "density": 139.8386317, + "specific_heat": 0.199866246, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.85, + "visible_absorptance": 0.85, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "MAT-CC05 8 HW CONCRETE", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 8, + "conductivity": 9.089781528, + "resistance": 0.880109162, + "density": 139.8386317, + "specific_heat": 0.199866246, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.85, + "visible_absorptance": 0.85, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "MAT-SHEATH", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": 0.043699572, + "specific_heat": 0.000167192, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Building Semi-Cond Wall Insulation-0.54", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 0.604172732, + "conductivity": 0.339740118, + "resistance": 1.778337913, + "density": 16.54340955, + "specific_heat": 0.199866246, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Building Wall Insulation R-4.14 IP", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 1.404445223, + "conductivity": 0.339740118, + "resistance": 4.133881011, + "density": 16.54340955, + "specific_heat": 0.199866246, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Deck - 1/16 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.0625, + "conductivity": 314.4, + "resistance": 0.000198791, + "density": 488.22, + "specific_heat": 0.12, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Decking", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.059055118, + "conductivity": 312.0478318, + "resistance": 0.00018925, + "density": 479.4467372, + "specific_heat": 0.099933123, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.6, + "visible_absorptance": 0.6, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Floor - 16inOC - 2x10 - R30 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 9.383, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Floor - 16inOC - 2x12 - R38 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 10.756, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Floor - 16inOC - 2x6 - R0 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 0.003, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Floor - 16inOC - 2x6 - R11 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 5.309, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Floor - 16inOC - 2x6 - R13 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 5.854, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Floor - 16inOC - 2x6 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 6.92, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Floor - 16inOC - 2x8 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 7.414, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Floor - 16inOC - 2x8 - R22 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 7.815, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Floor - 24inOC - 2x10 - R30 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 12.443, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Floor - 24inOC - 2x12 - R38 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 14.569, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Floor - 24inOC - 2x6 - R0 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 0.003, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Floor - 24inOC - 2x6 - R11 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 6.576, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Floor - 24inOC - 2x6 - R13 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 7.544, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Floor - 24inOC - 2x6 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 9.037, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Floor - 24inOC - 2x8 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 9.564, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Floor - 24inOC - 2x8 - R22 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 10.336, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 16inOC - 2x10 - R25 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 10.16, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 16inOC - 2x10 - R30 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 10.92, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 16inOC - 2x12 - R30 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 11.42, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 16inOC - 2x12 - R38 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 12.34, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 16inOC - 2x14 - R38 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 12.97, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 16inOC - 2x4 - R11 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 6.01, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 16inOC - 2x4 - R13 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 6.52, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 16inOC - 2x4 - R15 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 6.96, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 16inOC - 2x4 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 6.52, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 16inOC - 2x6 - R11 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 6.39, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 16inOC - 2x6 - R13 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 6.96, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 16inOC - 2x6 - R15 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 8.16, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 16inOC - 2x6 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 8.26, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 16inOC - 2x8 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 8.68, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 16inOC - 2x8 - R21 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 9.01, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 24inOC - 2x10 - R25 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 12.97, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 24inOC - 2x10 - R30 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 14.13, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 24inOC - 2x12 - R30 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 14.65, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 24inOC - 2x12 - R38 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 16.44, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 24inOC - 2x14 - R38 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 17.13, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 24inOC - 2x4 - R11 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 7.27, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 24inOC - 2x4 - R13 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 8.06, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 24inOC - 2x4 - R15 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 8.68, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 24inOC - 2x4 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 8.06, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 24inOC - 2x6 - R11 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 7.61, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 24inOC - 2x6 - R13 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 8.36, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 24inOC - 2x6 - R15 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 9.89, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 24inOC - 2x6 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 10.31, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 24inOC - 2x8 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 10.76, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Roof - 24inOC - 2x8 - R21 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 11.42, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Wall - 16inOC - 2x4 - R0 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 0.643, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Wall - 16inOC - 2x4 - R11 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 2.924, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Wall - 16inOC - 2x4 - R13 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 3.068, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Wall - 16inOC - 2x4 - R15 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 3.199, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Wall - 16inOC - 2x4 - R5 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 1.309, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Wall - 16inOC - 2x6 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 3.924, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Wall - 16inOC - 2x6 - R21 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 4.078, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Wall - 16inOC - 2x8 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 4.558, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Wall - 16inOC - 2x8 - R22 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 4.71, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Wall - 16inOC - 2x8 - R25 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 4.789, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Wall - 16inOC - 2x8 - R30 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 4.829, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Wall - 24inOC - 2x4 - R0 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 0.658, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Wall - 24inOC - 2x4 - R11 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 3.222, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Wall - 24inOC - 2x4 - R13 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 3.386, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Wall - 24inOC - 2x4 - R15 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 3.536, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Wall - 24inOC - 2x4 - R5 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 1.463, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Wall - 24inOC - 2x6 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 4.558, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Wall - 24inOC - 2x6 - R21 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 4.671, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Wall - 24inOC - 2x8 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 4.996, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Wall - 24inOC - 2x8 - R22 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 5.171, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Wall - 24inOC - 2x8 - R25 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 5.263, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Framed Wall - 24inOC - 2x8 - R30 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 5.309, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Insulated Panels - 2 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.5, + "conductivity": 0.16644, + "resistance": 15.02042778, + "density": 28.47, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Insulated Panels - 2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2, + "conductivity": 0.16704, + "resistance": 11.97318008, + "density": 34.87, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Insulated Panels - 3 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 3, + "conductivity": 0.16656, + "resistance": 18.01152738, + "density": 24.11, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Insulated Panels - 4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 4, + "conductivity": 0.16992, + "resistance": 23.54048964, + "density": 18.54, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Insulated Panels - 5 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 5, + "conductivity": 0.1698, + "resistance": 29.44640754, + "density": 15.14, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Insulated Panels - 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6, + "conductivity": 0.16584, + "resistance": 36.17945007, + "density": 12.84, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Roof Insulation R-5.21 IP", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 1.769246081, + "conductivity": 0.339740118, + "resistance": 5.207645452, + "density": 16.54340955, + "specific_heat": 0.199866246, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Roof Surface", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.031496063, + "conductivity": 313.947603, + "resistance": 0.000100323, + "density": 488.4363635, + "specific_heat": 0.119422948, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Roof Surface - Cool Roof", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.031496063, + "conductivity": 313.947603, + "resistance": 0.000100323, + "density": 488.4363635, + "specific_heat": 0.119422948, + "thermal_absorptance": 0.75, + "solar_absorptance": 0.37, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Roof Surface - Highly Reflective", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.031496063, + "conductivity": 313.947603, + "resistance": 0.000100323, + "density": 488.4363635, + "specific_heat": 0.119422948, + "thermal_absorptance": 0.75, + "solar_absorptance": 0.45, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Roofing", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.059055118, + "conductivity": 312.0478318, + "resistance": 0.00018925, + "density": 479.4467372, + "specific_heat": 0.099933123, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.6, + "visible_absorptance": 0.6, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Roofing - Cool Roof", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.059055118, + "conductivity": 312.0478318, + "resistance": 0.00018925, + "density": 479.4467372, + "specific_heat": 0.099933123, + "thermal_absorptance": 0.75, + "solar_absorptance": 0.37, + "visible_absorptance": 0.6, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Roofing - Highly Reflective", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.059055118, + "conductivity": 312.0478318, + "resistance": 0.00018925, + "density": 479.4467372, + "specific_heat": 0.099933123, + "thermal_absorptance": 0.75, + "solar_absorptance": 0.45, + "visible_absorptance": 0.6, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Screw Down Roof - No Thrml Blk - R10 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 5.756, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Screw Down Roof - No Thrml Blk - R11 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 6.414, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Screw Down Roof - No Thrml Blk - R13ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 6.912, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Screw Down Roof - No Thrml Blk - R16 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 8.654, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Screw Down Roof - No Thrml Blk - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 9.424, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Semi-Cond Roof Insulation-1.05", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 1.664068118, + "conductivity": 0.339740118, + "resistance": 4.898061868, + "density": 16.54340955, + "specific_heat": 0.199866246, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Siding", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.059055118, + "conductivity": 311.7288921, + "resistance": 0.000189444, + "density": 479.999849, + "specific_heat": 0.097926818, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Siding - 1/16 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.0625, + "conductivity": 314.4, + "resistance": 0.000198791, + "density": 488.22, + "specific_heat": 0.12, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Standing Seam - 1/16 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.0625, + "conductivity": 3.9996, + "resistance": 0.015626563, + "density": 488.22, + "specific_heat": 0.12, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Standing Seam - 1/16 in. CBES", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 0.06, + "conductivity": 4.0241, + "resistance": null, + "density": 488.22, + "specific_heat": 0.12, + "thermal_absorptance": 0.85, + "solar_absorptance": 0.37, + "visible_absorptance": 0.85, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R10 + R10 Ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 15.093, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R10 + R11 Ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 15.613, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R10 + R13 Ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 16.461, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R10 + R19 Ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 18.451, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R11 + R11 Ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 15.887, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R11 + R13 Ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 16.764, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R11 + R19 Ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 18.828, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R13 + R13 Ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 17.402, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R13 + R19 Ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 19.628, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R16 + R19 Ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 20.497, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R19 + R19 Ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 20.959, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Standing Seam Roof - Thrml Blk - Ins. and Filled Cavity - R19 + R10 Ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 23.61, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Standing Seam Roof - Thrml Blk - R10 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 9.529, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Standing Seam Roof - Thrml Blk - R11 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 10.09, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Standing Seam Roof - Thrml Blk - R13 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 11.268, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Standing Seam Roof - Thrml Blk - R16 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 13.109, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Standing Seam Roof - Thrml Blk - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 14.605, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Standing Seam Roof - Thrml Blk - R6 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 5.208, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Metal Surface", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.031496063, + "conductivity": 313.947603, + "resistance": 0.000100323, + "density": 488.4363635, + "specific_heat": 0.119422948, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Mortar - Cement - 1 3/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 1.76, + "conductivity": 5.01, + "resistance": 0.351297405, + "density": 116, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Mortar - Cement - 1 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 1.01, + "conductivity": 5.0304, + "resistance": 0.200779262, + "density": 116, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "NACM_Carpet 3/4in", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.75, + "conductivity": 0.34691, + "resistance": null, + "density": 18, + "specific_heat": 0.33, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.9, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "NACM_Concrete 4in_140lb/ft3", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 4, + "conductivity": 13.52932, + "resistance": null, + "density": 139.78, + "specific_heat": 0.22, + "thermal_absorptance": 0.75, + "solar_absorptance": 0.92, + "visible_absorptance": 0.75, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "NACM_Gypsum Board 5/8in", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 0.63, + "conductivity": 1.1101, + "resistance": null, + "density": 40, + "specific_heat": 0.27, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.5, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Nonres_Floor_Insulation", + "material_type": "MasslessOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": null, + "conductivity": null, + "resistance": 16.3699766, + "density": null, + "specific_heat": null, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Oak - 1 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1, + "conductivity": 1.1796, + "resistance": 0.847744998, + "density": 43.93, + "specific_heat": 0.39, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "OSB - Oriented Strand Board - 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.5, + "conductivity": 0.6204, + "resistance": 0.805931657, + "density": 41, + "specific_heat": 0.45, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "OSB - Oriented Strand Board - 3/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.75, + "conductivity": 0.9096, + "resistance": 0.824538259, + "density": 41, + "specific_heat": 0.45, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "OSB - Oriented Strand Board - 5/8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.63, + "conductivity": 0.7596, + "resistance": 0.829383886, + "density": 41, + "specific_heat": 0.45, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Perlite board - 1 1/2 in. R3.8", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 1.5, + "conductivity": 0.3996, + "resistance": 3.753753754, + "density": 10, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Perlite board - 1 in. R2.5", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 1, + "conductivity": 0.3996, + "resistance": 2.502502503, + "density": 10, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Perlite board - 2 in. R5.0", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 2, + "conductivity": 0.3996, + "resistance": 5.005005005, + "density": 10, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Perlite board - 3/4 in. R1.9", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 0.75, + "conductivity": 0.3996, + "resistance": 1.876876877, + "density": 10, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Perlite plaster - 25 lb/ft3 - 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.5, + "conductivity": 0.6, + "resistance": 0.833333333, + "density": 25, + "specific_heat": 0.32, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Perlite plaster - 38 lb/ft3 - 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.5, + "conductivity": 1.2996, + "resistance": 0.384733764, + "density": 38, + "specific_heat": 0.32, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Pine (oven-dried) - 1 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1, + "conductivity": 0.6396, + "resistance": 1.563477173, + "density": 23, + "specific_heat": 0.45, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Plaster/Sand Aggregate - 1 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 1.01, + "conductivity": 5.0304, + "resistance": 0.200779262, + "density": 116, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Plywood - 1 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1.5, + "conductivity": 0.8004, + "resistance": 1.874062969, + "density": 30, + "specific_heat": 0.45, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Plywood - 1 1/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1.25, + "conductivity": 0.8004, + "resistance": 1.56171914, + "density": 30, + "specific_heat": 0.45, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Plywood - 1 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1, + "conductivity": 0.8004, + "resistance": 1.249375312, + "density": 30, + "specific_heat": 0.45, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Plywood - 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.5, + "conductivity": 0.8004, + "resistance": 0.624687656, + "density": 30, + "specific_heat": 0.45, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Plywood - 1/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.25, + "conductivity": 0.8004, + "resistance": 0.312343828, + "density": 30, + "specific_heat": 0.45, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Plywood - 3/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.75, + "conductivity": 0.8004, + "resistance": 0.937031484, + "density": 30, + "specific_heat": 0.45, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Plywood - 3/8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.38, + "conductivity": 0.8004, + "resistance": 0.474762619, + "density": 30, + "specific_heat": 0.45, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Plywood - 5/8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.63, + "conductivity": 0.8004, + "resistance": 0.787106447, + "density": 30, + "specific_heat": 0.45, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Plywood - 5/8 in. CBES", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.63, + "conductivity": 0.83257, + "resistance": null, + "density": 30, + "specific_heat": 0.45, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Pulpboard or paper plaster - 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.5, + "conductivity": 0.5004, + "resistance": 0.999200639, + "density": 38, + "specific_heat": 0.32, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "PYR B CLEAR 3MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.118110236, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.74, + "front_side_solar_reflectance_at_normal_incidence": 0.09, + "back_side_solar_reflectance_at_normal_incidence": 0.1, + "visible_transmittance_at_normal_incidence": 0.82, + "front_side_visible_reflectance_at_normal_incidence": 0.11, + "back_side_visible_reflectance_at_normal_incidence": 0.12, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.2, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "PYR B CLEAR 6MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.236220472, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.68, + "front_side_solar_reflectance_at_normal_incidence": 0.09, + "back_side_solar_reflectance_at_normal_incidence": 0.1, + "visible_transmittance_at_normal_incidence": 0.81, + "front_side_visible_reflectance_at_normal_incidence": 0.11, + "back_side_visible_reflectance_at_normal_incidence": 0.12, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.2, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "R_R30", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 4.78807, + "conductivity": 0.15963, + "resistance": 30, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.8, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "R_R38", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.06489, + "conductivity": 0.15963, + "resistance": 38, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.8, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "R_T24_2013_24.86", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 3.96771, + "conductivity": 0.15963, + "resistance": 24.86, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.8, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "R-24 Batt Wall - 8 in. R24", + "material_type": "StandardOpaqueMaterial", + "roughness": "VeryRough", + "thickness": 8, + "conductivity": 0.3336, + "resistance": 23.98081535, + "density": 1.19, + "specific_heat": 0.23, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "R1_R14.20", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.26635, + "conductivity": 0.15963, + "resistance": 14.2, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.8, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "R2_R12.90", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.05887, + "conductivity": 0.15963, + "resistance": 12.9, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.8, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "R3_R17.74", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.83134, + "conductivity": 0.15963, + "resistance": 17.74, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.8, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "R4_R20.28", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 3.23667, + "conductivity": 0.15963, + "resistance": 20.28, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.8, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Rammed Earth", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 18, + "conductivity": 1.4796, + "resistance": 12.16545012, + "density": 115, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "REF A CLEAR LO 6MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.236220472, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.066, + "front_side_solar_reflectance_at_normal_incidence": 0.341, + "back_side_solar_reflectance_at_normal_incidence": 0.493, + "visible_transmittance_at_normal_incidence": 0.08, + "front_side_visible_reflectance_at_normal_incidence": 0.41, + "back_side_visible_reflectance_at_normal_incidence": 0.37, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.4, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "REF A CLEAR MID 6MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.236220472, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.11, + "front_side_solar_reflectance_at_normal_incidence": 0.27, + "back_side_solar_reflectance_at_normal_incidence": 0.43, + "visible_transmittance_at_normal_incidence": 0.14, + "front_side_visible_reflectance_at_normal_incidence": 0.31, + "back_side_visible_reflectance_at_normal_incidence": 0.35, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.47, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "REF A TINT MID 6MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.236220472, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.06, + "front_side_solar_reflectance_at_normal_incidence": 0.13, + "back_side_solar_reflectance_at_normal_incidence": 0.42, + "visible_transmittance_at_normal_incidence": 0.09, + "front_side_visible_reflectance_at_normal_incidence": 0.14, + "back_side_visible_reflectance_at_normal_incidence": 0.35, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.47, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "REF B CLEAR HI 6MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.236220472, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.24, + "front_side_solar_reflectance_at_normal_incidence": 0.16, + "back_side_solar_reflectance_at_normal_incidence": 0.32, + "visible_transmittance_at_normal_incidence": 0.3, + "front_side_visible_reflectance_at_normal_incidence": 0.16, + "back_side_visible_reflectance_at_normal_incidence": 0.29, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.6, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "REF B CLEAR LO 6MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.236220472, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.15, + "front_side_solar_reflectance_at_normal_incidence": 0.22, + "back_side_solar_reflectance_at_normal_incidence": 0.38, + "visible_transmittance_at_normal_incidence": 0.2, + "front_side_visible_reflectance_at_normal_incidence": 0.23, + "back_side_visible_reflectance_at_normal_incidence": 0.33, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.58, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "REF B TINT HI 6MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.236220472, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.15, + "front_side_solar_reflectance_at_normal_incidence": 0.09, + "back_side_solar_reflectance_at_normal_incidence": 0.33, + "visible_transmittance_at_normal_incidence": 0.18, + "front_side_visible_reflectance_at_normal_incidence": 0.08, + "back_side_visible_reflectance_at_normal_incidence": 0.28, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.6, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "REF B TINT MID 6MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.236220472, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.1, + "front_side_solar_reflectance_at_normal_incidence": 0.11, + "back_side_solar_reflectance_at_normal_incidence": 0.41, + "visible_transmittance_at_normal_incidence": 0.13, + "front_side_visible_reflectance_at_normal_incidence": 0.1, + "back_side_visible_reflectance_at_normal_incidence": 0.32, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.45, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "REF C CLEAR HI 6MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.236220472, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.2, + "front_side_solar_reflectance_at_normal_incidence": 0.16, + "back_side_solar_reflectance_at_normal_incidence": 0.39, + "visible_transmittance_at_normal_incidence": 0.22, + "front_side_visible_reflectance_at_normal_incidence": 0.17, + "back_side_visible_reflectance_at_normal_incidence": 0.35, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.55, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "REF C CLEAR MID 6MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.236220472, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.17, + "front_side_solar_reflectance_at_normal_incidence": 0.2, + "back_side_solar_reflectance_at_normal_incidence": 0.42, + "visible_transmittance_at_normal_incidence": 0.19, + "front_side_visible_reflectance_at_normal_incidence": 0.21, + "back_side_visible_reflectance_at_normal_incidence": 0.38, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.51, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "REF D CLEAR 6MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.236220472, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.429, + "front_side_solar_reflectance_at_normal_incidence": 0.308, + "back_side_solar_reflectance_at_normal_incidence": 0.379, + "visible_transmittance_at_normal_incidence": 0.334, + "front_side_visible_reflectance_at_normal_incidence": 0.453, + "back_side_visible_reflectance_at_normal_incidence": 0.505, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.82, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "REF D TINT 6MM", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.236220472, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.3, + "front_side_solar_reflectance_at_normal_incidence": 0.14, + "back_side_solar_reflectance_at_normal_incidence": 0.36, + "visible_transmittance_at_normal_incidence": 0.25, + "front_side_visible_reflectance_at_normal_incidence": 0.18, + "back_side_visible_reflectance_at_normal_incidence": 0.45, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.84, + "back_side_infrared_hemispherical_emissivity": 0.82, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "Roof Gravel - 1 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "VeryRough", + "thickness": 1, + "conductivity": 9.9996, + "resistance": 0.100004, + "density": 159.74, + "specific_heat": 0.19, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Roof Gravel - 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "VeryRough", + "thickness": 0.5, + "conductivity": 9.9996, + "resistance": 0.050002, + "density": 159.74, + "specific_heat": 0.19, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Roof Insulation [18]", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 6.665354331, + "conductivity": 0.339740118, + "resistance": 19.61897926, + "density": 16.54340955, + "specific_heat": 0.199866246, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Roof Membrane", + "material_type": "StandardOpaqueMaterial", + "roughness": "VeryRough", + "thickness": 0.374015748, + "conductivity": 1.109355488, + "resistance": 0.337146886, + "density": 69.99984791, + "specific_heat": 0.348715009, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Roof Membrane - Cool Roof", + "material_type": "StandardOpaqueMaterial", + "roughness": "VeryRough", + "thickness": 0.374015748, + "conductivity": 1.109355488, + "resistance": 0.337146886, + "density": 69.99984791, + "specific_heat": 0.348715009, + "thermal_absorptance": 0.75, + "solar_absorptance": 0.37, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Roof Membrane - Highly Reflective", + "material_type": "StandardOpaqueMaterial", + "roughness": "VeryRough", + "thickness": 0.374015748, + "conductivity": 1.109355488, + "resistance": 0.337146886, + "density": 69.99984791, + "specific_heat": 0.348715009, + "thermal_absorptance": 0.75, + "solar_absorptance": 0.45, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Roofing felt - 1/8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "VeryRough", + "thickness": 0.13, + "conductivity": 8.3004, + "resistance": 0.015661896, + "density": 141, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Rubber tile - 1 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1, + "conductivity": 0.3396, + "resistance": 2.944640754, + "density": 119, + "specific_heat": 0.48, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Sand aggregate - 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.5, + "conductivity": 5.4504, + "resistance": 0.091736386, + "density": 105, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Sand aggregate - 3/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.75, + "conductivity": 5.0796, + "resistance": 0.147649421, + "density": 116, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Sand aggregate - 3/8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.38, + "conductivity": 5.1504, + "resistance": 0.073780677, + "density": 116, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Sand aggregate - 5/8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.63, + "conductivity": 5.6004, + "resistance": 0.112491965, + "density": 105, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Sand aggregate on metal lath - 3/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.75, + "conductivity": 5.7696, + "resistance": 0.129991681, + "density": 105, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Shingles - Asbestos cement - lapped - 1/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "VeryRough", + "thickness": 0.25, + "conductivity": 1.1904, + "resistance": 0.210013441, + "density": 120, + "specific_heat": 0.24, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Shingles - Asphalt roll siding - 1/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "VeryRough", + "thickness": 0.25, + "conductivity": 1.6704, + "resistance": 0.149664751, + "density": 70, + "specific_heat": 0.36, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Shingles - Wood - 16 in. - 7 1/2 in. exposure - 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 0.5, + "conductivity": 0.57, + "resistance": 0.877192982, + "density": 22, + "specific_heat": 0.31, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Shingles - Wood - plus insulated backer board Siding - 5/16 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 0.31, + "conductivity": 0.2196, + "resistance": 1.411657559, + "density": 22, + "specific_heat": 0.31, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Siding - Asphalt insulating siding - 1/2 in. bed - 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "VeryRough", + "thickness": 0.5, + "conductivity": 0.3396, + "resistance": 1.472320377, + "density": 70, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Siding - Wood - bevel - 10 in. - lapped - 3/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 0.75, + "conductivity": 0.7104, + "resistance": 1.055743243, + "density": 22, + "specific_heat": 0.28, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.23, + "solar_heat_gain_coefficient": 0.61, + "visible_transmittance": 0.25, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - Crawl Space - R22 - Double 2x Spline - 6 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.5, + "conductivity": 0.24768, + "resistance": 26.24354005, + "density": 7.15, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - Crawl Space - R22 - I Joist Spline - 6 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.5, + "conductivity": 0.23148, + "resistance": 28.08017971, + "density": 7.15, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - Crawl Space - R22 - Single 2x Spline - 6 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.5, + "conductivity": 0.23952, + "resistance": 27.13760855, + "density": 7.15, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - Crawl Space - R28 - Double 2x Spline - 8 1/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 8.25, + "conductivity": 0.25356, + "resistance": 32.53667771, + "density": 5.85, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - Crawl Space - R28 - I Joist Spline - 8 1/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 8.25, + "conductivity": 0.2436, + "resistance": 33.86699507, + "density": 5.85, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - Crawl Space - R28 - Single 2x Spline - 8 1/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 8.25, + "conductivity": 0.2436, + "resistance": 33.86699507, + "density": 5.85, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - Crawl Space - R33 - Double 2x Spline - 6 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.5, + "conductivity": 0.1842, + "resistance": 35.28773073, + "density": 7.15, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - Crawl Space - R33 - I Joist Spline - 6 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.5, + "conductivity": 0.16884, + "resistance": 38.49798626, + "density": 7.15, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - Crawl Space - R33 - Single 2x Spline - 6 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.5, + "conductivity": 0.16884, + "resistance": 38.49798626, + "density": 7.15, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - Crawl Space - R36 - Double 2x Spline - 10 1/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 10.25, + "conductivity": 0.26628, + "resistance": 38.49331531, + "density": 4.9, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - Crawl Space - R36 - I Joist Spline - 10 1/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 10.25, + "conductivity": 0.2424, + "resistance": 42.28547855, + "density": 4.9, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - Crawl Space - R36 - Single 2x Spline - 10 1/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 10.25, + "conductivity": 0.25428, + "resistance": 40.3098946, + "density": 4.9, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - No Crawl Space - R22 - Double 2x Spline - 6 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.5, + "conductivity": 0.32364, + "resistance": 20.084044, + "density": 7.15, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - No Crawl Space - R22 - I Joist Spline - 6 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.5, + "conductivity": 0.29772, + "resistance": 21.83259438, + "density": 7.15, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - No Crawl Space - R22 - Single 2x Spline - 6 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.5, + "conductivity": 0.30636, + "resistance": 21.21686904, + "density": 7.15, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - No Crawl Space - R28 - Double 2x Spline - 8 1/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 8.25, + "conductivity": 0.3144, + "resistance": 26.24045802, + "density": 5.85, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - No Crawl Space - R28 - I Joist Spline - 8 1/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 8.25, + "conductivity": 0.29376, + "resistance": 28.08415033, + "density": 5.85, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - No Crawl Space - R28 - Single 2x Spline - 8 1/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 8.25, + "conductivity": 0.30408, + "resistance": 27.13101815, + "density": 5.85, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - No Crawl Space - R33 - Double 2x Spline - 6 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.5, + "conductivity": 0.23148, + "resistance": 28.08017971, + "density": 7.15, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - No Crawl Space - R33 - I Joist Spline - 6 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.5, + "conductivity": 0.19968, + "resistance": 32.55208333, + "density": 7.15, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - No Crawl Space - R33 - Single 2x Spline - 6 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.5, + "conductivity": 0.2076, + "resistance": 31.31021195, + "density": 7.15, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - No Crawl Space - R36 - Double 2x Spline - 10 1/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 10.25, + "conductivity": 0.315, + "resistance": 32.53968254, + "density": 4.9, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - No Crawl Space - R36 - I Joist Spline - 10 1/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 10.25, + "conductivity": 0.2904, + "resistance": 35.29614325, + "density": 4.9, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - No Crawl Space - R36 - Single 2x Spline - 10 1/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 10.25, + "conductivity": 0.2904, + "resistance": 35.29614325, + "density": 4.9, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R14 - Double 2x Spline - 4 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 4.5, + "conductivity": 0.39312, + "resistance": 11.44688645, + "density": 9.89, + "specific_heat": 0.31, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R14 - I joist Spline - 4 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 4.5, + "conductivity": 0.35304, + "resistance": 12.746431, + "density": 9.89, + "specific_heat": 0.31, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R14 - Metal Spline - 48 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 48, + "conductivity": 4.14, + "resistance": 11.5942029, + "density": 1.83, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R14 - OSB Spline - 4 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 4.5, + "conductivity": 0.303, + "resistance": 14.85148515, + "density": 9.89, + "specific_heat": 0.31, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R14 - Single 2x Spline - 4 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 4.5, + "conductivity": 0.35868, + "resistance": 12.54600201, + "density": 9.89, + "specific_heat": 0.31, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R18 - Double 2x Spline - 4 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 4.5, + "conductivity": 0.3306, + "resistance": 13.61161525, + "density": 9.89, + "specific_heat": 0.31, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R18 - I joist Spline - 4 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 4.5, + "conductivity": 0.29208, + "resistance": 15.40673788, + "density": 9.89, + "specific_heat": 0.31, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R18 - OSB Spline - 4 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 4.5, + "conductivity": 0.25968, + "resistance": 17.32902033, + "density": 9.89, + "specific_heat": 0.31, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R18 - Single 2x Spline - 4 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 4.5, + "conductivity": 0.303, + "resistance": 14.85148515, + "density": 9.89, + "specific_heat": 0.31, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R22 - Double 2x Spline - 6 1/2 in. (Roof)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.5, + "conductivity": 0.32496, + "resistance": 20.00246184, + "density": 7.15, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R22 - Double 2x Spline - 6 1/2 in. (Wall)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.5, + "conductivity": 0.3828, + "resistance": 16.98014629, + "density": 7.15, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R22 - I joist Spline - 6 1/2 in. (Roof)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.5, + "conductivity": 0.30216, + "resistance": 21.51178184, + "density": 7.15, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R22 - I joist Spline - 6 1/2 in. (Wall)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.5, + "conductivity": 0.33696, + "resistance": 19.29012346, + "density": 7.15, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R22 - Metal Spline - 48 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 48, + "conductivity": 3.0396, + "resistance": 15.79155152, + "density": 1.83, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R22 - OSB Spline - 6 1/2 in. (Roof)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.5, + "conductivity": 0.28692, + "resistance": 22.65439844, + "density": 7.15, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R22 - OSB Spline - 6 1/2 in. (Wall)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.5, + "conductivity": 0.28452, + "resistance": 22.84549417, + "density": 7.15, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R22 - Single 2x Spline - 6 1/2 in. (Roof)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.5, + "conductivity": 0.3096, + "resistance": 20.99483204, + "density": 7.15, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R22 - Single 2x Spline - 6 1/2 in. (Wall)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.5, + "conductivity": 0.35208, + "resistance": 18.46171325, + "density": 7.15, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R28 - Double 2x Spline - 8 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 8.5, + "conductivity": 0.33612, + "resistance": 25.28858741, + "density": 5.71, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R28 - Double 2x Spline - 8 1/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 8.25, + "conductivity": 0.37992, + "resistance": 21.71509792, + "density": 5.85, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R28 - I joist Spline - 8 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 8.5, + "conductivity": 0.2976, + "resistance": 28.56182796, + "density": 5.71, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R28 - I joist Spline - 8 1/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 8.25, + "conductivity": 0.32364, + "resistance": 25.49128661, + "density": 5.85, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R28 - Metal Spline - 48 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 48, + "conductivity": 2.45688, + "resistance": 19.53697372, + "density": 1.83, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R28 - OSB Spline - 8 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 8.5, + "conductivity": 0.2976, + "resistance": 28.56182796, + "density": 5.71, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R28 - OSB Spline - 8 1/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 8.25, + "conductivity": 0.27768, + "resistance": 29.71045808, + "density": 5.85, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R28 - Single 2x Spline - 8 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 8.5, + "conductivity": 0.3072, + "resistance": 27.66927083, + "density": 5.71, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R28 - Single 2x Spline - 8 1/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 8.25, + "conductivity": 0.34236, + "resistance": 24.09744129, + "density": 5.85, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R33 - Double 2x Spline - 6 1/2 in. (Roof)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.5, + "conductivity": 0.23484, + "resistance": 27.67841935, + "density": 7.15, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R33 - Double 2x Spline - 6 1/2 in. (Wall)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.5, + "conductivity": 0.29928, + "resistance": 21.71879177, + "density": 7.15, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R33 - I joist Spline - 6 1/2 in. (Roof)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.5, + "conductivity": 0.213, + "resistance": 30.51643192, + "density": 7.15, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R33 - I joist Spline - 6 1/2 in. (Wall)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.5, + "conductivity": 0.24768, + "resistance": 26.24354005, + "density": 7.15, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R33 - OSB Spline - 6 1/2 in. (Roof)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.5, + "conductivity": 0.2058, + "resistance": 31.5840622, + "density": 7.15, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R33 - OSB Spline - 6 1/2 in. (Wall)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.5, + "conductivity": 0.21876, + "resistance": 29.71292741, + "density": 7.15, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R33 - Single 2x Spline - 6 1/2 in. (Roof)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.5, + "conductivity": 0.213, + "resistance": 30.51643192, + "density": 7.15, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R33 - Single 2x Spline - 6 1/2 in. (Wall)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.5, + "conductivity": 0.26232, + "resistance": 24.778896, + "density": 7.15, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R36 - Double 2x Spline - 10 1/4 in. (Roof)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 10.25, + "conductivity": 0.31308, + "resistance": 32.73923598, + "density": 4.9, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R36 - Double 2x Spline - 10 1/4 in. (Wall)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 10.25, + "conductivity": 0.3792, + "resistance": 27.03059072, + "density": 4.9, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R36 - I joist Spline - 10 1/4 in. (Roof)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 10.25, + "conductivity": 0.2904, + "resistance": 35.29614325, + "density": 4.9, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R36 - I joist Spline - 10 1/4 in. (Wall)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 10.25, + "conductivity": 0.32244, + "resistance": 31.78885994, + "density": 4.9, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R36 - Metal Spline - 48 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 48, + "conductivity": 2.2296, + "resistance": 21.5285253, + "density": 1.83, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R36 - OSB Spline - 10 1/4 in. (Roof)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 10.25, + "conductivity": 0.27912, + "resistance": 36.72255661, + "density": 4.9, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R36 - OSB Spline - 10 1/4 in. (Wall)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 10.25, + "conductivity": 0.27756, + "resistance": 36.9289523, + "density": 4.9, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R36 - Single 2x Spline - 10 1/4 in. (Roof)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 10.25, + "conductivity": 0.30168, + "resistance": 33.97639883, + "density": 4.9, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R36 - Single 2x Spline - 10 1/4 in. (Wall)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 10.25, + "conductivity": 0.345, + "resistance": 29.71014493, + "density": 4.9, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R44 - Double 2x Spline - 12 1/4 in. (Roof)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 12.25, + "conductivity": 0.32016, + "resistance": 38.26211894, + "density": 4.27, + "specific_heat": 0.28, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R44 - Double 2x Spline - 12 1/4 in. (Wall)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 12.25, + "conductivity": 0.35844, + "resistance": 34.17587323, + "density": 4.27, + "specific_heat": 0.28, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R44 - I joist Spline - 12 1/4 in. (Roof)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 12.25, + "conductivity": 0.2802, + "resistance": 43.71877231, + "density": 4.27, + "specific_heat": 0.28, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R44 - I joist Spline - 12 1/4 in. (Wall)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 12.25, + "conductivity": 0.31848, + "resistance": 38.46395378, + "density": 4.27, + "specific_heat": 0.28, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R44 - OSB Spline - 12 1/4 in. (Roof)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 12.25, + "conductivity": 0.267, + "resistance": 45.88014981, + "density": 4.27, + "specific_heat": 0.28, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R44 - OSB Spline - 12 1/4 in. (Wall)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 12.25, + "conductivity": 0.279, + "resistance": 43.90681004, + "density": 4.27, + "specific_heat": 0.28, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R44 - Single 2x Spline - 12 1/4 in. (Roof)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 12.25, + "conductivity": 0.29352, + "resistance": 41.73480512, + "density": 4.27, + "specific_heat": 0.28, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R44 - Single 2x Spline - 12 1/4 in. (Wall)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 12.25, + "conductivity": 0.34512, + "resistance": 35.49490032, + "density": 4.27, + "specific_heat": 0.28, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R55 - Double 2x Spline - 10 1/4 in. (Roof)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 10.25, + "conductivity": 0.22344, + "resistance": 45.8736126, + "density": 4.9, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R55 - Double 2x Spline - 10 1/4 in. (Wall)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 10.25, + "conductivity": 0.3, + "resistance": 34.16666667, + "density": 4.9, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R55 - I joist Spline - 10 1/4 in. (Roof)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 10.25, + "conductivity": 0.19044, + "resistance": 53.82272632, + "density": 4.9, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R55 - I joist Spline - 10 1/4 in. (Wall)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 10.25, + "conductivity": 0.2334, + "resistance": 43.91602399, + "density": 4.9, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R55 - OSB Spline - 10 1/4 in. (Roof)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 10.25, + "conductivity": 0.17952, + "resistance": 57.09670232, + "density": 4.9, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R55 - OSB Spline - 10 1/4 in. (Wall)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 10.25, + "conductivity": 0.21156, + "resistance": 48.4496124, + "density": 4.9, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R55 - Single 2x Spline - 10 1/4 in. (Roof)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 10.25, + "conductivity": 0.20136, + "resistance": 50.90385379, + "density": 4.9, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "SIPS - R55 - Single 2x Spline - 10 1/4 in. (Wall)", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 10.25, + "conductivity": 0.25548, + "resistance": 40.12055738, + "density": 4.9, + "specific_heat": 0.29, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Skylight_Frame_Width_0.000_in", + "material_type": null, + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 0, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": 0, + "annotation": null + }, + { + "name": "Skylight_Frame_Width_0.334_in", + "material_type": null, + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 0.02, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": 0.334, + "annotation": null + }, + { + "name": "Skylight_Frame_Width_0.430_in", + "material_type": null, + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 0.02, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": 0.43, + "annotation": null + }, + { + "name": "Skylight_Frame_Width_0.709_in", + "material_type": null, + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 0.02, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": 0.709, + "annotation": null + }, + { + "name": "Skylight_Frame_Width_2.339_in", + "material_type": null, + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 0.02, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": 2.339, + "annotation": null + }, + { + "name": "Slate - 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "VeryRough", + "thickness": 0.5, + "conductivity": 11.0304, + "resistance": 0.045329272, + "density": 119.81, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Slate or tile - 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "VeryRough", + "thickness": 0.5, + "conductivity": 11.0304, + "resistance": 0.045329272, + "density": 119.81, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 3 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 3.5, + "conductivity": 0.3204, + "resistance": 10.92384519, + "density": 4.6, + "specific_heat": 0.34, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 4 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 4.5, + "conductivity": 0.3204, + "resistance": 14.04494382, + "density": 4.6, + "specific_heat": 0.34, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 4, + "conductivity": 0.3204, + "resistance": 12.48439451, + "density": 4.6, + "specific_heat": 0.34, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 5 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 5.5, + "conductivity": 0.3204, + "resistance": 17.16604245, + "density": 4.6, + "specific_heat": 0.34, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 5 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 5, + "conductivity": 0.3204, + "resistance": 15.60549313, + "density": 4.6, + "specific_heat": 0.34, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 6 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 6.5, + "conductivity": 0.3204, + "resistance": 20.28714107, + "density": 4.6, + "specific_heat": 0.34, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 6, + "conductivity": 0.3204, + "resistance": 18.72659176, + "density": 4.6, + "specific_heat": 0.34, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Spray applied - Glass fiber - 3.9 lb/ft3 - 3 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 3.5, + "conductivity": 0.27, + "resistance": 12.96296296, + "density": 3.9, + "specific_heat": 0.23, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Spray applied - Glass fiber - 3.9 lb/ft3 - 4 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 4.5, + "conductivity": 0.27, + "resistance": 16.66666667, + "density": 3.9, + "specific_heat": 0.23, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Spray applied - Glass fiber - 3.9 lb/ft3 - 4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 4, + "conductivity": 0.27, + "resistance": 14.81481481, + "density": 3.9, + "specific_heat": 0.23, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Spray applied - Glass fiber - 3.9 lb/ft3 - 5 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 5.5, + "conductivity": 0.27, + "resistance": 20.37037037, + "density": 3.9, + "specific_heat": 0.23, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Spray applied - Glass fiber - 3.9 lb/ft3 - 5 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 5, + "conductivity": 0.27, + "resistance": 18.51851852, + "density": 3.9, + "specific_heat": 0.23, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Spray applied - Glass fiber - 3.9 lb/ft3 - 6 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 6.5, + "conductivity": 0.27, + "resistance": 24.07407407, + "density": 3.9, + "specific_heat": 0.23, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Spray applied - Glass fiber - 3.9 lb/ft3 - 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 6, + "conductivity": 0.27, + "resistance": 22.22222222, + "density": 3.9, + "specific_heat": 0.23, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Spray applied - Polyurethane foam - 0.5 lb/ft3 - 3 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 3.5, + "conductivity": 0.3, + "resistance": 11.66666667, + "density": 0.5, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Spray applied - Polyurethane foam - 0.5 lb/ft3 - 4 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 4.5, + "conductivity": 0.3, + "resistance": 15, + "density": 0.5, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Spray applied - Polyurethane foam - 0.5 lb/ft3 - 4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 4, + "conductivity": 0.3, + "resistance": 13.33333333, + "density": 0.5, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Spray applied - Polyurethane foam - 0.5 lb/ft3 - 5 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 5.5, + "conductivity": 0.3, + "resistance": 18.33333333, + "density": 0.5, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Spray applied - Polyurethane foam - 0.5 lb/ft3 - 5 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 5, + "conductivity": 0.3, + "resistance": 16.66666667, + "density": 0.5, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Spray applied - Polyurethane foam - 0.5 lb/ft3 - 6 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 6.5, + "conductivity": 0.3, + "resistance": 21.66666667, + "density": 0.5, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Spray applied - Polyurethane foam - 0.5 lb/ft3 - 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 6, + "conductivity": 0.3, + "resistance": 20, + "density": 0.5, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Spray applied - Polyurethane foam - 3.0 lb/ft3 - 3 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 3.5, + "conductivity": 0.20004, + "resistance": 17.4965007, + "density": 3, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Spray applied - Polyurethane foam - 3.0 lb/ft3 - 4 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 4.5, + "conductivity": 0.20004, + "resistance": 22.4955009, + "density": 3, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Spray applied - Polyurethane foam - 3.0 lb/ft3 - 4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 4, + "conductivity": 0.20004, + "resistance": 19.9960008, + "density": 3, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Spray applied - Polyurethane foam - 3.0 lb/ft3 - 5 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 5.5, + "conductivity": 0.20004, + "resistance": 27.4945011, + "density": 3, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Spray applied - Polyurethane foam - 3.0 lb/ft3 - 5 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 5, + "conductivity": 0.20004, + "resistance": 24.995001, + "density": 3, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Spray applied - Polyurethane foam - 3.0 lb/ft3 - 6 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 6.5, + "conductivity": 0.20004, + "resistance": 32.4935013, + "density": 3, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Spray applied - Polyurethane foam - 3.0 lb/ft3 - 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 6, + "conductivity": 0.20004, + "resistance": 29.9940012, + "density": 3, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Std Wood 6 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 5.905511811, + "conductivity": 0.832016616, + "resistance": 7.097829176, + "density": 33.71109871, + "specific_heat": 0.289003535, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Std Wood 6inch Furnishings", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 5.91, + "conductivity": 0.83257, + "resistance": null, + "density": 33.71, + "specific_heat": 0.29, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Steel Frame NonRes Wall Insulation-0.73", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 0.79835618, + "conductivity": 0.339740118, + "resistance": 2.34990258, + "density": 16.54340955, + "specific_heat": 0.199866246, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Steel Frame Wall Insulation R-1.02 IP", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 0.347890885, + "conductivity": 0.339740118, + "resistance": 1.023991182, + "density": 16.54340955, + "specific_heat": 0.199866246, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Steel Frame/Cavity", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 3.500007095, + "conductivity": 0.583217221, + "resistance": 6.001206697, + "density": 40.03997387, + "specific_heat": 0.119919749, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Stone - 1 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 1, + "conductivity": 12.504, + "resistance": 0.079974408, + "density": 139.78, + "specific_heat": 0.22, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Straw Bale - Int and Ext Stucco - 18 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 19.5, + "conductivity": 0.6504, + "resistance": 29.98154982, + "density": 12.95, + "specific_heat": 0.11, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Structural Glazing - Double glass with no low e coatings - No Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.27, + "conductivity": 0.81, + "resistance": 2.802469136, + "density": 29.09, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Structural Glazing - Double glass with no low e coatings - R10 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 3.27, + "conductivity": 0.5304, + "resistance": 6.165158371, + "density": 20.44, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Structural Glazing - Double glass with no low e coatings - R15 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 4.47, + "conductivity": 0.64764, + "resistance": 6.901982583, + "density": 15.23, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Structural Glazing - Double glass with no low e coatings - R20 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 5.67, + "conductivity": 0.7704, + "resistance": 7.359813084, + "density": 12.22, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Structural Glazing - Double glass with no low e coatings - R25 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.87, + "conductivity": 0.8904, + "resistance": 7.715633423, + "density": 10.26, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Structural Glazing - Double glass with no low e coatings - R30 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 8.07, + "conductivity": 1.02, + "resistance": 7.911764706, + "density": 8.88, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Structural Glazing - Double glass with no low e coatings - R4 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 1.83, + "conductivity": 0.39, + "resistance": 4.692307692, + "density": 35.69, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Structural Glazing - Double glass with no low e coatings - R7 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.55, + "conductivity": 0.4596, + "resistance": 5.548302872, + "density": 25.92, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Structural Glazing - Single glass pane. stone. or metal pane - No Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.52, + "conductivity": 1.2804, + "resistance": 1.968134958, + "density": 41.9, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Structural Glazing - Single glass pane. stone. or metal pane - R10 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 3.52, + "conductivity": 0.5904, + "resistance": 5.962059621, + "density": 30.2, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Structural Glazing - Single glass pane. stone. or metal pane - R15 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 4.72, + "conductivity": 0.6996, + "resistance": 6.746712407, + "density": 22.79, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Structural Glazing - Single glass pane. stone. or metal pane - R20 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 5.92, + "conductivity": 0.81324, + "resistance": 7.27952388, + "density": 18.37, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Structural Glazing - Single glass pane. stone. or metal pane - R25 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 7.12, + "conductivity": 0.93372, + "resistance": 7.625412329, + "density": 15.45, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Structural Glazing - Single glass pane. stone. or metal pane - R30 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 8.32, + "conductivity": 1.05, + "resistance": 7.923809524, + "density": 13.37, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Structural Glazing - Single glass pane. stone. or metal pane - R4 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.08, + "conductivity": 0.48624, + "resistance": 4.277722935, + "density": 50.36, + "specific_heat": 0.25, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Structural Glazing - Single glass pane. stone. or metal pane - R7 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.8, + "conductivity": 0.5304, + "resistance": 5.279034691, + "density": 37.69, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Structural Glazing - Triple or low e glass - No Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.27, + "conductivity": 0.6504, + "resistance": 3.490159902, + "density": 29.09, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Structural Glazing - Triple or low e glass - R10 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 3.27, + "conductivity": 0.51, + "resistance": 6.411764706, + "density": 20.44, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Structural Glazing - Triple or low e glass - R15 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 4.47, + "conductivity": 0.63636, + "resistance": 7.024325853, + "density": 15.23, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Structural Glazing - Triple or low e glass - R20 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 5.67, + "conductivity": 0.76476, + "resistance": 7.414090695, + "density": 12.22, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Structural Glazing - Triple or low e glass - R25 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 6.87, + "conductivity": 0.88404, + "resistance": 7.771141577, + "density": 10.26, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Structural Glazing - Triple or low e glass - R30 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 8.07, + "conductivity": 1.0104, + "resistance": 7.986935867, + "density": 8.88, + "specific_heat": 0.27, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Structural Glazing - Triple or low e glass - R4 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 1.83, + "conductivity": 0.36, + "resistance": 5.083333333, + "density": 35.69, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Structural Glazing - Triple or low e glass - R7 Ins.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.55, + "conductivity": 0.43836, + "resistance": 5.8171366, + "density": 25.92, + "specific_heat": 0.26, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Stucco - 3/8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.38, + "conductivity": 5.0004, + "resistance": 0.07599392, + "density": 115.81, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Stucco - 7/8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.88, + "conductivity": 4.86, + "resistance": 0.181069959, + "density": 115.81, + "specific_heat": 0.2, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Stucco - 7/8 in. CBES", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 0.88, + "conductivity": 4.85668, + "resistance": null, + "density": 115.81, + "specific_heat": 0.2, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.8, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Synthetic Stucco - EIFS finish - 1 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 1, + "conductivity": 0.2496, + "resistance": 4.006410256, + "density": 1.5, + "specific_heat": 0.35, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Terrazzo - 1 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 1, + "conductivity": 12.5004, + "resistance": 0.07999744, + "density": 160, + "specific_heat": 0.19, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Test", + "material_type": "Test", + "roughness": "Test", + "thickness": 0.1, + "conductivity": 0.1, + "resistance": 0.1, + "density": 0.1, + "specific_heat": 0.1, + "thermal_absorptance": 0.1, + "solar_absorptance": 0.1, + "visible_absorptance": 0.1, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Theoretical Glass [167]", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.118110236, + "conductivity": 14.61090512, + "resistance": 0.06844203, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.2374, + "front_side_solar_reflectance_at_normal_incidence": 0.7126, + "back_side_solar_reflectance_at_normal_incidence": 0.7126, + "visible_transmittance_at_normal_incidence": 0.2512, + "front_side_visible_reflectance_at_normal_incidence": 0.6988, + "back_side_visible_reflectance_at_normal_incidence": 0.6988, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.985, + "back_side_infrared_hemispherical_emissivity": 0.985, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "Theoretical Glass [197]", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.118110236, + "conductivity": 0.28773908, + "resistance": 3.475370816, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.2349, + "front_side_solar_reflectance_at_normal_incidence": 0.7151, + "back_side_solar_reflectance_at_normal_incidence": 0.7151, + "visible_transmittance_at_normal_incidence": 0.2512, + "front_side_visible_reflectance_at_normal_incidence": 0.6988, + "back_side_visible_reflectance_at_normal_incidence": 0.6988, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.9, + "back_side_infrared_hemispherical_emissivity": 0.9, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "Theoretical Glass [202]", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.118110236, + "conductivity": 0.133122659, + "resistance": 7.511869212, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.2325, + "front_side_solar_reflectance_at_normal_incidence": 0.7175, + "back_side_solar_reflectance_at_normal_incidence": 0.7175, + "visible_transmittance_at_normal_incidence": 0.3192, + "front_side_visible_reflectance_at_normal_incidence": 0.6308, + "back_side_visible_reflectance_at_normal_incidence": 0.6308, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.9, + "back_side_infrared_hemispherical_emissivity": 0.9, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "Theoretical Glass [207]", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.118110236, + "conductivity": 0.092215175, + "resistance": 10.84420217, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.3311, + "front_side_solar_reflectance_at_normal_incidence": 0.6189, + "back_side_solar_reflectance_at_normal_incidence": 0.6189, + "visible_transmittance_at_normal_incidence": 0.44, + "front_side_visible_reflectance_at_normal_incidence": 0.51, + "back_side_visible_reflectance_at_normal_incidence": 0.51, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.9, + "back_side_infrared_hemispherical_emissivity": 0.9, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "Theoretical Glass [216]", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.118110236, + "conductivity": 0.092215175, + "resistance": 10.84420217, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.3801, + "front_side_solar_reflectance_at_normal_incidence": 0.5699, + "back_side_solar_reflectance_at_normal_incidence": 0.5699, + "visible_transmittance_at_normal_incidence": 0.5079, + "front_side_visible_reflectance_at_normal_incidence": 0.4421, + "back_side_visible_reflectance_at_normal_incidence": 0.4421, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.9, + "back_side_infrared_hemispherical_emissivity": 0.9, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "Theoretical Glass [221]", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.118110236, + "conductivity": 0.061707899, + "resistance": 16.20538077, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.4296, + "front_side_solar_reflectance_at_normal_incidence": 0.5204, + "back_side_solar_reflectance_at_normal_incidence": 0.5204, + "visible_transmittance_at_normal_incidence": 0.4503, + "front_side_visible_reflectance_at_normal_incidence": 0.4997, + "back_side_visible_reflectance_at_normal_incidence": 0.4997, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.9, + "back_side_infrared_hemispherical_emissivity": 0.9, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "Theoretical Glass 297", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.118110236, + "conductivity": 0.071803727, + "resistance": 13.92685363, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.375039, + "front_side_solar_reflectance_at_normal_incidence": 0.574961, + "back_side_solar_reflectance_at_normal_incidence": 0.574961, + "visible_transmittance_at_normal_incidence": 0.529698, + "front_side_visible_reflectance_at_normal_incidence": 0.420302, + "back_side_visible_reflectance_at_normal_incidence": 0.420302, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.9, + "back_side_infrared_hemispherical_emissivity": 0.9, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "Theoretical Glass 347", + "material_type": "StandardGlazing", + "roughness": null, + "thickness": 0.118110236, + "conductivity": 0.071816901, + "resistance": 13.92429898, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": "SpectralAverage", + "solar_transmittance_at_normal_incidence": 0.315861, + "front_side_solar_reflectance_at_normal_incidence": 0.634139, + "back_side_solar_reflectance_at_normal_incidence": 0.634139, + "visible_transmittance_at_normal_incidence": 0.479911, + "front_side_visible_reflectance_at_normal_incidence": 0.470089, + "back_side_visible_reflectance_at_normal_incidence": 0.470089, + "infrared_transmittance_at_normal_incidence": 0, + "front_side_infrared_hemispherical_emissivity": 0.9, + "back_side_infrared_hemispherical_emissivity": 0.9, + "dirt_correction_factor_for_solar_and_visible_transmittance": 1, + "solar_diffusing": "FALSE", + "frame_width": null, + "annotation": null + }, + { + "name": "Tile Gap - 3/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "VeryRough", + "thickness": 0.75, + "conductivity": 0.6612, + "resistance": 1.13430127, + "density": 70, + "specific_heat": 0.24, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Typical Air Wall", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": 0.043699572, + "specific_heat": 0.000167192, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Typical Carpet Pad", + "material_type": "MasslessOpaqueMaterial", + "roughness": "VeryRough", + "thickness": null, + "conductivity": null, + "resistance": 1.229230374, + "density": null, + "specific_heat": null, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.8, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Typical Insulation", + "material_type": "MasslessOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": null, + "conductivity": 6.240124619, + "resistance": 0.16025321, + "density": 0.043699572, + "specific_heat": 0.000167192, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.11 SHGC 0.34 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.11, + "solar_heat_gain_coefficient": 0.34, + "visible_transmittance": 0.374, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.11 SHGC 0.38 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.11, + "solar_heat_gain_coefficient": 0.38, + "visible_transmittance": 0.418, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.12 SHGC 0.34 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.12, + "solar_heat_gain_coefficient": 0.34, + "visible_transmittance": 0.374, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.12 SHGC 0.38 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.12, + "solar_heat_gain_coefficient": 0.38, + "visible_transmittance": 0.418, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.13 SHGC 0.32 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.13, + "solar_heat_gain_coefficient": 0.32, + "visible_transmittance": 0.352, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.13 SHGC 0.38 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.13, + "solar_heat_gain_coefficient": 0.38, + "visible_transmittance": 0.418, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.14 SHGC 0.31 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.14, + "solar_heat_gain_coefficient": 0.31, + "visible_transmittance": 0.341, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.14 SHGC 0.34 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.14, + "solar_heat_gain_coefficient": 0.34, + "visible_transmittance": 0.374, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.14 SHGC 0.36 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.14, + "solar_heat_gain_coefficient": 0.36, + "visible_transmittance": 0.396, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.14 SHGC 0.38 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.14, + "solar_heat_gain_coefficient": 0.38, + "visible_transmittance": 0.418, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.15 SHGC 0.31 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.15, + "solar_heat_gain_coefficient": 0.31, + "visible_transmittance": 0.341, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.15 SHGC 0.34 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.15, + "solar_heat_gain_coefficient": 0.34, + "visible_transmittance": 0.374, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.17 SHGC 0.31 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.17, + "solar_heat_gain_coefficient": 0.31, + "visible_transmittance": 0.341, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.17 SHGC 0.32 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.17, + "solar_heat_gain_coefficient": 0.32, + "visible_transmittance": 0.352, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.17 SHGC 0.36 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.17, + "solar_heat_gain_coefficient": 0.36, + "visible_transmittance": 0.396, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.18 SHGC 0.22 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.18, + "solar_heat_gain_coefficient": 0.22, + "visible_transmittance": 0.242, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.18 SHGC 0.24 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.18, + "solar_heat_gain_coefficient": 0.24, + "visible_transmittance": 0.264, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.20 SHGC 0.19 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.2, + "solar_heat_gain_coefficient": 0.19, + "visible_transmittance": 0.209, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.20 SHGC 0.20 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.2, + "solar_heat_gain_coefficient": 0.2, + "visible_transmittance": 0.22, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.20 SHGC 0.21 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.2, + "solar_heat_gain_coefficient": 0.21, + "visible_transmittance": 0.231, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.20 SHGC 0.22 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.2, + "solar_heat_gain_coefficient": 0.22, + "visible_transmittance": 0.242, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.23 SHGC 0.31 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.23, + "solar_heat_gain_coefficient": 0.31, + "visible_transmittance": 0.341, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.23 SHGC 0.34 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.23, + "solar_heat_gain_coefficient": 0.34, + "visible_transmittance": 0.374, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.25 SHGC 0.22 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.25, + "solar_heat_gain_coefficient": 0.22, + "visible_transmittance": 0.242, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.25 SHGC 0.24 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.25, + "solar_heat_gain_coefficient": 0.24, + "visible_transmittance": 0.264, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.26 SHGC 0.40 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.26, + "solar_heat_gain_coefficient": 0.4, + "visible_transmittance": 0.44, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.29 SHGC 0.40 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.29, + "solar_heat_gain_coefficient": 0.4, + "visible_transmittance": 0.44, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.32 SHGC 0.36 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.32, + "solar_heat_gain_coefficient": 0.36, + "visible_transmittance": 0.396, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.35 SHGC 0.22 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.35, + "solar_heat_gain_coefficient": 0.22, + "visible_transmittance": 0.242, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.35 SHGC 0.24 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.35, + "solar_heat_gain_coefficient": 0.24, + "visible_transmittance": 0.264, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.42 SHGC 0.34 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.42, + "solar_heat_gain_coefficient": 0.34, + "visible_transmittance": 0.374, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.45 SHGC 0.33 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.45, + "solar_heat_gain_coefficient": 0.33, + "visible_transmittance": 0.363, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.47 SHGC 0.33 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.47, + "solar_heat_gain_coefficient": 0.33, + "visible_transmittance": 0.363, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.48 SHGC 0.19 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.48, + "solar_heat_gain_coefficient": 0.19, + "visible_transmittance": 0.209, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.48 SHGC 0.21 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.48, + "solar_heat_gain_coefficient": 0.21, + "visible_transmittance": 0.231, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.48 SHGC 0.20 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.48, + "solar_heat_gain_coefficient": 0.2, + "visible_transmittance": 0.22, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.48 SHGC 0.22 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.48, + "solar_heat_gain_coefficient": 0.22, + "visible_transmittance": 0.242, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.50 SHGC 0.22 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.5, + "solar_heat_gain_coefficient": 0.22, + "visible_transmittance": 0.242, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.50 SHGC 0.23 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.5, + "solar_heat_gain_coefficient": 0.23, + "visible_transmittance": 0.253, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.52 SHGC 0.39 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.52, + "solar_heat_gain_coefficient": 0.39, + "visible_transmittance": 0.31, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.52 SHGC 0.49 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.52, + "solar_heat_gain_coefficient": 0.49, + "visible_transmittance": 0.41, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.52 SHGC 0.615 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.52, + "solar_heat_gain_coefficient": 0.615, + "visible_transmittance": 0.41, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.54 SHGC 0.23 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.54, + "solar_heat_gain_coefficient": 0.23, + "visible_transmittance": 0.253, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.58 SHGC 0.19 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.58, + "solar_heat_gain_coefficient": 0.19, + "visible_transmittance": 0.15, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.58 SHGC 0.36 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.58, + "solar_heat_gain_coefficient": 0.36, + "visible_transmittance": 0.25, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.59 SHGC 0.36 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.59, + "solar_heat_gain_coefficient": 0.36, + "visible_transmittance": 0.27, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.59 SHGC 0.39 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.59, + "solar_heat_gain_coefficient": 0.39, + "visible_transmittance": 0.31, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.60 SHGC 0.23 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.6, + "solar_heat_gain_coefficient": 0.23, + "visible_transmittance": 0.253, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.61 SHGC 0.77 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.61, + "solar_heat_gain_coefficient": 0.77, + "visible_transmittance": 0.6, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.62 SHGC 0.20 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.62, + "solar_heat_gain_coefficient": 0.2, + "visible_transmittance": 0.22, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.62 SHGC 0.21 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.62, + "solar_heat_gain_coefficient": 0.21, + "visible_transmittance": 0.231, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.62 SHGC 0.41 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.62, + "solar_heat_gain_coefficient": 0.41, + "visible_transmittance": 0.32, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.65 SHGC 0.35 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.65, + "solar_heat_gain_coefficient": 0.35, + "visible_transmittance": 0.25, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.69 SHGC 0.19 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.69, + "solar_heat_gain_coefficient": 0.19, + "visible_transmittance": 0.15, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.69 SHGC 0.36 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.69, + "solar_heat_gain_coefficient": 0.36, + "visible_transmittance": 0.23, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.69 SHGC 0.39 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.69, + "solar_heat_gain_coefficient": 0.39, + "visible_transmittance": 0.23, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.69 SHGC 0.49 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.69, + "solar_heat_gain_coefficient": 0.49, + "visible_transmittance": 0.38, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.69 SHGC 0.64 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.69, + "solar_heat_gain_coefficient": 0.64, + "visible_transmittance": 0.55, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.69 SHGC 0.68 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.69, + "solar_heat_gain_coefficient": 0.68, + "visible_transmittance": 0.55, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.72 SHGC 0.25 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.72, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": 0.13, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.72 SHGC 0.36 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.72, + "solar_heat_gain_coefficient": 0.36, + "visible_transmittance": 0.23, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.72 SHGC 0.39 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.72, + "solar_heat_gain_coefficient": 0.39, + "visible_transmittance": 0.23, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.74 SHGC 0.55 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.74, + "solar_heat_gain_coefficient": 0.55, + "visible_transmittance": 0.4, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.74 SHGC 0.65 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.74, + "solar_heat_gain_coefficient": 0.65, + "visible_transmittance": 0.55, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.75 SHGC 0.35 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.75, + "solar_heat_gain_coefficient": 0.35, + "visible_transmittance": 0.23, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.81 SHGC 0.65 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.81, + "solar_heat_gain_coefficient": 0.65, + "visible_transmittance": 0.55, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.85 SHGC 0.65 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.85, + "solar_heat_gain_coefficient": 0.65, + "visible_transmittance": 0.55, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.87 SHGC 0.58 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.87, + "solar_heat_gain_coefficient": 0.58, + "visible_transmittance": 0.55, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.87 SHGC 0.71 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.87, + "solar_heat_gain_coefficient": 0.71, + "visible_transmittance": 0.6, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.87 SHGC 0.77 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.87, + "solar_heat_gain_coefficient": 0.77, + "visible_transmittance": 0.6, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.98 SHGC 0.19 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.98, + "solar_heat_gain_coefficient": 0.19, + "visible_transmittance": 0.15, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.98 SHGC 0.36 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.98, + "solar_heat_gain_coefficient": 0.36, + "visible_transmittance": 0.25, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.10 SHGC 0.62 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.1, + "solar_heat_gain_coefficient": 0.62, + "visible_transmittance": 0.55, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.10 SHGC 0.77 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.1, + "solar_heat_gain_coefficient": 0.77, + "visible_transmittance": 0.6, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.15 SHGC 0.77 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.15, + "solar_heat_gain_coefficient": 0.77, + "visible_transmittance": 0.6, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.17 SHGC 0.19 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.17, + "solar_heat_gain_coefficient": 0.19, + "visible_transmittance": 0.15, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.17 SHGC 0.36 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.17, + "solar_heat_gain_coefficient": 0.36, + "visible_transmittance": 0.23, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.17 SHGC 0.39 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.17, + "solar_heat_gain_coefficient": 0.39, + "visible_transmittance": 0.23, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.17 SHGC 0.49 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.17, + "solar_heat_gain_coefficient": 0.49, + "visible_transmittance": 0.38, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.17 SHGC 0.64 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.17, + "solar_heat_gain_coefficient": 0.64, + "visible_transmittance": 0.55, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.17 SHGC 0.68 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.17, + "solar_heat_gain_coefficient": 0.68, + "visible_transmittance": 0.55, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.22 SHGC 0.25 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.22, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": 0.11, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.22 SHGC 0.54 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.22, + "solar_heat_gain_coefficient": 0.54, + "visible_transmittance": 0.38, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.30 SHGC 0.27 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.3, + "solar_heat_gain_coefficient": 0.27, + "visible_transmittance": 0.25, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.30 SHGC 0.34 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.3, + "solar_heat_gain_coefficient": 0.34, + "visible_transmittance": 0.25, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.30 SHGC 0.62 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.3, + "solar_heat_gain_coefficient": 0.62, + "visible_transmittance": 0.55, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.30 SHGC 0.65 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.3, + "solar_heat_gain_coefficient": 0.65, + "visible_transmittance": 0.55, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.36 SHGC 0.19 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.36, + "solar_heat_gain_coefficient": 0.19, + "visible_transmittance": 0.15, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.36 SHGC 0.36 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.36, + "solar_heat_gain_coefficient": 0.36, + "visible_transmittance": 0.23, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.36 SHGC 0.39 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.36, + "solar_heat_gain_coefficient": 0.39, + "visible_transmittance": 0.23, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.36 SHGC 0.61 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.36, + "solar_heat_gain_coefficient": 0.61, + "visible_transmittance": 0.23, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.70 SHGC 0.36 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.7, + "solar_heat_gain_coefficient": 0.36, + "visible_transmittance": 0.23, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.80 SHGC 0.36 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.8, + "solar_heat_gain_coefficient": 0.36, + "visible_transmittance": 0.23, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.90 SHGC 0.27 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.9, + "solar_heat_gain_coefficient": 0.27, + "visible_transmittance": 0.25, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.90 SHGC 0.34 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.9, + "solar_heat_gain_coefficient": 0.34, + "visible_transmittance": 0.25, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.90 SHGC 0.39 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.9, + "solar_heat_gain_coefficient": 0.39, + "visible_transmittance": 0.25, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.90 SHGC 0.65 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.9, + "solar_heat_gain_coefficient": 0.65, + "visible_transmittance": 0.25, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.98 SHGC 0.16 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.98, + "solar_heat_gain_coefficient": 0.16, + "visible_transmittance": 0.15, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.98 SHGC 0.19 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.98, + "solar_heat_gain_coefficient": 0.19, + "visible_transmittance": 0.15, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.98 SHGC 0.36 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.98, + "solar_heat_gain_coefficient": 0.36, + "visible_transmittance": 0.25, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.98 SHGC 0.39 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.98, + "solar_heat_gain_coefficient": 0.39, + "visible_transmittance": 0.25, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.98 SHGC 0.61 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.98, + "solar_heat_gain_coefficient": 0.61, + "visible_transmittance": 0.25, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U0.47_SHGC_0.49_SimpleGlazing_Window_05", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": "Air", + "u_factor": 0.47, + "solar_heat_gain_coefficient": 0.49, + "visible_transmittance": 0.81, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U0.47_SHGC0.46_SimpleGlazing_Window_07", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": "Air", + "u_factor": 0.47, + "solar_heat_gain_coefficient": 0.46, + "visible_transmittance": 0.81, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U0.47_SHGC0.47_SimpleGlazing_Window_06", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": "Air", + "u_factor": 0.47, + "solar_heat_gain_coefficient": 0.47, + "visible_transmittance": 0.81, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U0.47_SHGC0.47_SimpleGlazing_Window_11", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": "Air", + "u_factor": 0.47, + "solar_heat_gain_coefficient": 0.47, + "visible_transmittance": 0.81, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U0.47_SHGC0.5_SimpleGlazing_Window_03", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": "Air", + "u_factor": 0.47, + "solar_heat_gain_coefficient": 0.5, + "visible_transmittance": 0.81, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U0.77_SHGC_0.77_SimpleGlazing_Window_02", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": "Air", + "u_factor": 0.77, + "solar_heat_gain_coefficient": 0.77, + "visible_transmittance": 0.81, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U0.77_SHGC0.5_SimpleGlazing_Window_09", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": "Air", + "u_factor": 0.77, + "solar_heat_gain_coefficient": 0.5, + "visible_transmittance": 0.81, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U0.77_SHGC0.61_SimpleGlazing_Window_08", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": "Air", + "u_factor": 0.77, + "solar_heat_gain_coefficient": 0.61, + "visible_transmittance": 0.81, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U0.77_SHGC0.62_SimpleGlazing_Window_04", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": "Air", + "u_factor": 0.77, + "solar_heat_gain_coefficient": 0.62, + "visible_transmittance": 0.81, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U1.23_SHGC0.5_SimpleGlazing_Window_12", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": "Air", + "u_factor": 1.23, + "solar_heat_gain_coefficient": 0.5, + "visible_transmittance": 0.81, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U1.23_SHGC0.82_SimpleGlazing_Window_01", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": "Air", + "u_factor": 1.23, + "solar_heat_gain_coefficient": 0.82, + "visible_transmittance": 0.81, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U1.23_SHGC0.82_SimpleGlazing_Window_10", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": "Air", + "u_factor": 1.23, + "solar_heat_gain_coefficient": 0.62, + "visible_transmittance": 0.81, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Vapor permeable felt - 1/8 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 0.13, + "conductivity": 2.0796, + "resistance": 0.062512022, + "density": 22, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Vapor seal - 2 layers of mopped 15 lb felt - 1/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 0.25, + "conductivity": 2.0796, + "resistance": 0.120215426, + "density": 22, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Vapor seal - plastic film - 1/16 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Rough", + "thickness": 0.63, + "conductivity": 62.4996, + "resistance": 0.010080065, + "density": 30, + "specific_heat": 0.3, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Vermiculite aggregate - 45 lb/ft3 - 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 0.5, + "conductivity": 1.7004, + "resistance": 0.294048459, + "density": 45, + "specific_heat": 0.32, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "W_m1_R15", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.39403, + "conductivity": 0.15963, + "resistance": 15, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.8, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "W_m2_R19", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 3.03244, + "conductivity": 0.15963, + "resistance": 19, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.8, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "W_m3_R21", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 3.35165, + "conductivity": 0.15963, + "resistance": 21, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.8, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "W_T24_2013_R13.99", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.23284, + "conductivity": 0.15963, + "resistance": 13.99, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.8, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "W1_R8.60", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 1.37252, + "conductivity": 0.15963, + "resistance": 8.6, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.8, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "W2_R11.13", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 1.77634, + "conductivity": 0.15963, + "resistance": 11.13, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.8, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "W3_R11.36", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 1.81305, + "conductivity": 0.15963, + "resistance": 11.36, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.8, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "W4_R12.62", + "material_type": "StandardOpaqueMaterial", + "roughness": "Smooth", + "thickness": 2.01414, + "conductivity": 0.15963, + "resistance": 12.62, + "density": 1, + "specific_heat": 0.27, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.8, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wall Insulation [31]", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 1.326771654, + "conductivity": 0.299525982, + "resistance": 4.429571171, + "density": 5.680944412, + "specific_heat": 0.199914015, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.5, + "visible_absorptance": 0.5, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood - 1 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 1, + "conductivity": 1.0404, + "resistance": 0.961168781, + "density": 37.94, + "specific_heat": 0.39, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood - 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.5, + "conductivity": 1.0404, + "resistance": 0.480584391, + "density": 37.94, + "specific_heat": 0.39, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood - 2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 2, + "conductivity": 1.0404, + "resistance": 1.922337562, + "density": 37.94, + "specific_heat": 0.39, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood - 4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 4, + "conductivity": 1.0404, + "resistance": 3.844675125, + "density": 37.94, + "specific_heat": 0.39, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Frame NonRes Wall Insulation-0.73", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 0.79835618, + "conductivity": 0.339740118, + "resistance": 2.34990258, + "density": 16.54340955, + "specific_heat": 0.199866246, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Frame Wall Insulation R-1.61 IP", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumRough", + "thickness": 0.54621365, + "conductivity": 0.339740118, + "resistance": 1.607739625, + "density": 16.54340955, + "specific_heat": 0.199866246, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.7, + "visible_absorptance": 0.7, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x10 - R11 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 10.783, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x10 - R13 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 12.4765, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x10 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 17.1561, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x10 - R21 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 18.5953, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x10 - R22 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 19.2942, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x10 - R25 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 21.3129, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x10 - R30 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 24.4379, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x10 - R38 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 28.8982, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x10 - R44 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 31.873, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x10 - R49 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 34.1444, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x10 - R60 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 38.5802, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x12 - R11 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 11.0136, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x12 - R13 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 12.7862, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x12 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 17.7471, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x12 - R21 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 19.2917, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x12 - R22 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 20.045, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x12 - R25 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 22.2328, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x12 - R30 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 25.6551, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x12 - R38 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 30.6158, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x12 - R44 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 33.9752, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x12 - R49 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 36.5684, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x12 - R60 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 41.7037, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x4 - R11 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 9.0352, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x4 - R13 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 10.1946, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x4 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 13.1185, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x4 - R21 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 13.9437, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x4 - R22 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 14.333, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x4 - R25 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 15.4178, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x4 - R30 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 16.9895, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x4 - R38 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 19.0316, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x4 - R44 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 20.278, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x4 - R49 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 21.1742, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x4 - R60 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 22.7998, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x6 - R11 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 9.98167, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x6 - R13 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 11.416, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x6 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 15.2129, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x6 - R21 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 16.3338, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x6 - R22 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 16.8706, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x6 - R25 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 18.394, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x6 - R30 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 20.6759, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x6 - R38 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 23.7814, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x6 - R44 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 25.7599, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x6 - R49 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 27.2236, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x6 - R60 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 29.9711, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x8 - R11 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 10.4438, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x8 - R13 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 12.0246, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x8 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 16.313, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x8 - R21 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 17.6089, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x8 - R22 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 18.2344, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x8 - R25 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 20.0271, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x8 - R30 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 22.7622, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x8 - R38 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 26.584, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x8 - R44 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 29.0808, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x8 - R49 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 30.96, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 16inOC - 2x8 - R60 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 34.5633, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x10 - R11 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 10.8472, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x10 - R13 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 12.6291, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x10 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 17.6705, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x10 - R21 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 19.2568, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x10 - R22 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 20.0334, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x10 - R25 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 22.2995, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x10 - R30 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 25.8772, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x10 - R38 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 31.1355, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x10 - R44 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 34.7459, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x10 - R49 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 37.5607, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x10 - R60 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 43.2077, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x12 - R11 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 11.0095, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x12 - R13 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 12.8496, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x12 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 18.1053, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x12 - R21 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 19.7743, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x12 - R22 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 20.594, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x12 - R25 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 22.9964, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x12 - R30 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 26.8204, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x12 - R38 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 32.5111, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x12 - R44 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 36.4678, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x12 - R49 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 39.581, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x12 - R60 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 45.903, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x4 - R11 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 9.54677, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x4 - R13 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 10.9003, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x4 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 14.4614, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x4 - R21 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 15.5068, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x4 - R22 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 16.0065, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x4 - R25 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 17.421, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x4 - R30 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 19.5305, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x4 - R38 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 22.3835, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x4 - R44 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 24.1906, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x4 - R49 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 25.5222, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x4 - R60 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 28.0096, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x6 - R11 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 10.2668, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x6 - R13 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 11.8491, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x6 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 16.1804, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x6 - R21 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 17.5004, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x6 - R22 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 18.1394, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x6 - R25 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 19.9777, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x6 - R30 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 22.802, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x6 - R38 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 26.7885, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x6 - R44 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 29.4185, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x6 - R49 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 31.4116, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x6 - R60 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 35.2661, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x8 - R11 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 10.6047, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x8 - R13 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 12.3015, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x8 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 17.0358, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x8 - R21 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 18.5054, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x8 - R22 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 19.2214, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x8 - R25 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 21.298, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x8 - R30 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 24.5383, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x8 - R38 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 29.2172, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x8 - R44 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 32.3739, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x8 - R49 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 34.804, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Attic Floor - 24inOC - 2x8 - R60 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 39.5997, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Floor - 16inOC - 2x10 - R25 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 21.3129, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Floor - 16inOC - 2x10 - R30 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 24.4379, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Floor - 16inOC - 2x12 - R38 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 30.6158, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Floor - 16inOC - 2x6 - R11 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 9.98167, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Floor - 16inOC - 2x6 - R13 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 11.416, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Floor - 16inOC - 2x6 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 15.2129, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Floor - 16inOC - 2x8 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 16.313, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Floor - 16inOC - 2x8 - R22 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 18.2344, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Floor - 24inOC - 2x10 - R25 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 22.2995, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Floor - 24inOC - 2x10 - R30 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 25.8772, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Floor - 24inOC - 2x12 - R38 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 32.5111, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Floor - 24inOC - 2x6 - R11 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 10.2668, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Floor - 24inOC - 2x6 - R13 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 11.8491, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Floor - 24inOC - 2x6 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 16.1804, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Floor - 24inOC - 2x8 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 17.0358, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Floor - 24inOC - 2x8 - R22 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 19.2214, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 16inOC - 2x10 - R22 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 19.2942, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 16inOC - 2x10 - R25 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 21.3129, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 16inOC - 2x10 - R30 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 24.4379, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 16inOC - 2x12 - R30 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 25.6551, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 16inOC - 2x12 - R38 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 30.6158, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 16inOC - 2x14 - R38 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 30.6158, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 16inOC - 2x4 - R11 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 9.0352, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 16inOC - 2x4 - R13 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 10.1946, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 16inOC - 2x4 - R15 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 11.2537, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 16inOC - 2x4 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 13.1185, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 16inOC - 2x6 - R11 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 9.98167, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 16inOC - 2x6 - R13 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 11.416, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 16inOC - 2x6 - R15 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 12.7607, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 16inOC - 2x6 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 15.2129, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 16inOC - 2x6 - R21 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 16.3338, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 16inOC - 2x8 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 16.313, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 16inOC - 2x8 - R21 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 17.6089, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 24inOC - 2x10 - R22 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 20.0334, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 24inOC - 2x10 - R25 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 22.2995, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 24inOC - 2x10 - R30 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 25.8772, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 24inOC - 2x12 - R30 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 26.8204, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 24inOC - 2x12 - R38 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 32.5111, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 24inOC - 2x14 - R38 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 32.5111, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 24inOC - 2x4 - R11 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 9.54677, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 24inOC - 2x4 - R13 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 10.9003, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 24inOC - 2x4 - R15 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 12.1652, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 24inOC - 2x4 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 14.4614, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 24inOC - 2x6 - R11 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 10.2668, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 24inOC - 2x6 - R13 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 11.8491, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 24inOC - 2x6 - R15 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 13.359, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 24inOC - 2x6 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 16.1804, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 24inOC - 2x6 - R21 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 17.5004, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 24inOC - 2x8 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 17.0358, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Rafter Roof - 24inOC - 2x8 - R21 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 18.5054, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 16inOC - 2x4 - R11 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 7.12596, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 16inOC - 2x4 - R13 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 7.70165, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 16inOC - 2x4 - R15 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 8.18665, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 16inOC - 2x6 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 11.7113, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 16inOC - 2x6 - R21 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 12.2507, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 16inOC - 2x6 - R22 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 12.4993, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 16inOC - 2x8 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 13.4581, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 16inOC - 2x8 - R22 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 14.5092, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 16inOC - 2x8 - R25 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 15.4247, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 16inOC - 2x8 - R30 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 16.7137, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 24inOC - 2x4 - R11 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 7.44041, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 24inOC - 2x4 - R11 ins. AWS", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 8.03106, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 24inOC - 2x4 - R13 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 8.09769, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 24inOC - 2x4 - R13 ins. AWS", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 8.85675, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 24inOC - 2x4 - R15 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 8.6586, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 24inOC - 2x4 - R15 ins. AWS", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 9.57897, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 24inOC - 2x6 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 12.2765, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 24inOC - 2x6 - R19 ins. AWS", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 13.3502, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 24inOC - 2x6 - R21 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 12.8954, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 24inOC - 2x6 - R21 ins. AWS", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 14.1353, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 24inOC - 2x6 - R22 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 13.1824, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 24inOC - 2x6 - R22 ins. AWS", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 14.5036, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 24inOC - 2x8 - R19 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 13.9462, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 24inOC - 2x8 - R19 ins. AWS", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 14.8435, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 24inOC - 2x8 - R22 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 15.1272, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 24inOC - 2x8 - R22 ins. AWS", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 16.2834, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 24inOC - 2x8 - R25 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 16.1678, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 24inOC - 2x8 - R25 ins. AWS", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 17.5793, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 24inOC - 2x8 - R30 ins.", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 17.6518, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 24inOC - 2x8 - R30 ins. AWS", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 19.4735, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 48inOC - 2x4 - R11 ins. AWS", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 10.1197, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 48inOC - 2x4 - R13 ins. AWS", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 11.711, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 48inOC - 2x4 - R15 ins. AWS", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 13.2373, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 48inOC - 2x6 - R19 ins. AWS", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 17.2794, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 48inOC - 2x6 - R21 ins. AWS", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 18.8464, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 48inOC - 2x6 - R22 ins. AWS", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 19.6146, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 48inOC - 2x8 - R19 ins. AWS", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 17.8255, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 48inOC - 2x8 - R22 ins. AWS", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 20.3213, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 48inOC - 2x8 - R25 ins. AWS", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 22.7412, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Framed Wall - 48inOC - 2x8 - R30 ins. AWS", + "material_type": "MasslessOpaqueMaterial", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": 26.6149, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood shingles - 3/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "VeryRough", + "thickness": 0.75, + "conductivity": 0.8304, + "resistance": 0.903179191, + "density": 36.94, + "specific_heat": 0.31, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood shingles - plain and plastic film faced - 3/4 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "VeryRough", + "thickness": 0.75, + "conductivity": 0.8004, + "resistance": 0.937031484, + "density": 22, + "specific_heat": 0.31, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood Siding", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.393700787, + "conductivity": 0.762681898, + "resistance": 0.516205758, + "density": 33.99951589, + "specific_heat": 0.289003535, + "thermal_absorptance": 0.9, + "solar_absorptance": 0.78, + "visible_absorptance": 0.78, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "Wood siding - 1/2 in.", + "material_type": "StandardOpaqueMaterial", + "roughness": "MediumSmooth", + "thickness": 0.5, + "conductivity": 0.6204, + "resistance": 0.805931657, + "density": 36.94, + "specific_heat": 0.28, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": null, + "solar_heat_gain_coefficient": null, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.49 SHGC 0.22 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.49, + "solar_heat_gain_coefficient": 0.22, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.57 SHGC 0.25 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.57, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.53 SHGC 0.25 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.53, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.48 SHGC 0.25 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.48, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.38 SHGC 0.36 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.38, + "solar_heat_gain_coefficient": 0.36, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.38 SHGC 0.38 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.38, + "solar_heat_gain_coefficient": 0.38, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.36 SHGC 0.4 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.36, + "solar_heat_gain_coefficient": 0.4, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.33 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.33, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.29 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.29, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.5 SHGC 0.22 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.5, + "solar_heat_gain_coefficient": 0.22, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.54 SHGC 0.25 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.54, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.49 SHGC 0.25 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.49, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.45 SHGC 0.25 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.45, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.19 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.19, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.73 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.73, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.62 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.62, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.51 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.51, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.38 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.38, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.53 SHGC 0.22 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.53, + "solar_heat_gain_coefficient": 0.22, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.53 SHGC 0.23 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.53, + "solar_heat_gain_coefficient": 0.23, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.38 SHGC 0.35 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.38, + "solar_heat_gain_coefficient": 0.35, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.38 SHGC 0.37 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.38, + "solar_heat_gain_coefficient": 0.37, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.36 SHGC 0.37 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.36, + "solar_heat_gain_coefficient": 0.37, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.31 SHGC 0.39 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.31, + "solar_heat_gain_coefficient": 0.39, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.28 SHGC 0.39 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.28, + "solar_heat_gain_coefficient": 0.39, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.51 SHGC 0.22 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.51, + "solar_heat_gain_coefficient": 0.22, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.51 SHGC 0.23 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.51, + "solar_heat_gain_coefficient": 0.23, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.46 SHGC 0.25 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.46, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.43 SHGC 0.25 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.43, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.36 SHGC 0.36 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.36, + "solar_heat_gain_coefficient": 0.36, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.36 SHGC 0.38 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.36, + "solar_heat_gain_coefficient": 0.38, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.34 SHGC 0.38 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.34, + "solar_heat_gain_coefficient": 0.38, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.29 SHGC 0.4 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.29, + "solar_heat_gain_coefficient": 0.4, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.26 SHGC 0.4 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.26, + "solar_heat_gain_coefficient": 0.4, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.37 SHGC 0.36 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.37, + "solar_heat_gain_coefficient": 0.36, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.37 SHGC 0.38 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.37, + "solar_heat_gain_coefficient": 0.38, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.35 SHGC 0.38 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.35, + "solar_heat_gain_coefficient": 0.38, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.3 SHGC 0.4 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.3, + "solar_heat_gain_coefficient": 0.4, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.27 SHGC 0.4 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.27, + "solar_heat_gain_coefficient": 0.4, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.5 SHGC 0.23 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.5, + "solar_heat_gain_coefficient": 0.23, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.42 SHGC 0.25 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.42, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.47 SHGC 0.25 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.47, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.2 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.2, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.5 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.5, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.39 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.39, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.36 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.36, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.75 SHGC 0.35 Simple Glazing Window", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.75, + "solar_heat_gain_coefficient": 0.35, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.65 SHGC 0.35 Simple Glazing Window", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.65, + "solar_heat_gain_coefficient": 0.35, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.55 SHGC 0.35 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.55, + "solar_heat_gain_coefficient": 0.35, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.5 SHGC 0.4 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.5, + "solar_heat_gain_coefficient": 0.4, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.5 SHGC 0.55 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.5, + "solar_heat_gain_coefficient": 0.55, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.41 SHGC 0.55 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.41, + "solar_heat_gain_coefficient": 0.55, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.8 SHGC 0.55 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.8, + "solar_heat_gain_coefficient": 0.55, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.7 SHGC 0.55 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.7, + "solar_heat_gain_coefficient": 0.55, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.15 SHGC 0.55 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.15, + "solar_heat_gain_coefficient": 0.55, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.98 SHGC 0.55 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.98, + "solar_heat_gain_coefficient": 0.55, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.85 SHGC 0.55 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.85, + "solar_heat_gain_coefficient": 0.55, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.7 SHGC 0.3 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.7, + "solar_heat_gain_coefficient": 0.3, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.65 SHGC 0.3 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.65, + "solar_heat_gain_coefficient": 0.3, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.55 SHGC 0.3 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.55, + "solar_heat_gain_coefficient": 0.3, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.47 SHGC 0.4 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.47, + "solar_heat_gain_coefficient": 0.4, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.44 SHGC 0.55 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.44, + "solar_heat_gain_coefficient": 0.55, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.9 SHGC 0.55 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.9, + "solar_heat_gain_coefficient": 0.55, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.75 SHGC 0.55 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.75, + "solar_heat_gain_coefficient": 0.55, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.37 SHGC 0.25 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.37, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.83 SHGC 0.25 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.83, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.77 SHGC 0.25 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.77, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.93 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.93, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.83 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.83, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.65 SHGC 0.55 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.65, + "solar_heat_gain_coefficient": 0.55, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.8 SHGC 0.77 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.8, + "solar_heat_gain_coefficient": 0.77, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.65 SHGC 0.77 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.65, + "solar_heat_gain_coefficient": 0.77, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.65 SHGC 0.68 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.65, + "solar_heat_gain_coefficient": 0.68, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.8 SHGC 0.64 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.8, + "solar_heat_gain_coefficient": 0.64, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.33 SHGC 0.25 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.33, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.68 SHGC 0.25 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.68, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.87 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.87, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.77 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.77, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.55 SHGC 0.64 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.55, + "solar_heat_gain_coefficient": 0.64, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.55 SHGC 0.55 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.55, + "solar_heat_gain_coefficient": 0.55, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.31 SHGC 0.36 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.31, + "solar_heat_gain_coefficient": 0.36, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.68 SHGC 0.36 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.68, + "solar_heat_gain_coefficient": 0.36, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.31 SHGC 0.38 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.31, + "solar_heat_gain_coefficient": 0.38, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.68 SHGC 0.38 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.68, + "solar_heat_gain_coefficient": 0.38, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.45 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.45, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.5 SHGC 0.36 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.5, + "solar_heat_gain_coefficient": 0.36, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.5 SHGC 0.19 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.5, + "solar_heat_gain_coefficient": 0.19, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.5 SHGC 0.34 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.5, + "solar_heat_gain_coefficient": 0.34, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.98 SHGC 0.27 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.98, + "solar_heat_gain_coefficient": 0.27, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.98 SHGC 0.36 Simple Glazing Weighted", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.98, + "solar_heat_gain_coefficient": 0.36, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.68 SHGC 0.4 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.68, + "solar_heat_gain_coefficient": 0.4, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.85 SHGC 0.19 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.85, + "solar_heat_gain_coefficient": 0.19, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.85 SHGC 0.39 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.85, + "solar_heat_gain_coefficient": 0.39, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.28 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.28, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.68 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.68, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.32 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.32, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.5 SHGC 0.27 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.5, + "solar_heat_gain_coefficient": 0.27, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.25 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.25, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.5 SHGC 0.39 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.5, + "solar_heat_gain_coefficient": 0.39, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.5 SHGC 0.65 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.5, + "solar_heat_gain_coefficient": 0.65, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.85 SHGC 0.27 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.85, + "solar_heat_gain_coefficient": 0.27, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.5 SHGC 0.25 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.5, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.1 SHGC 0.25 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.1, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.1 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.1, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.75 SHGC 0.49 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.75, + "solar_heat_gain_coefficient": 0.49, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.8 SHGC 0.49 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.8, + "solar_heat_gain_coefficient": 0.49, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.75 SHGC 0.39 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.75, + "solar_heat_gain_coefficient": 0.39, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.75 SHGC 0.68 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.75, + "solar_heat_gain_coefficient": 0.68, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.75 SHGC 0.64 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.75, + "solar_heat_gain_coefficient": 0.64, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.77 SHGC 0.23 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.77, + "solar_heat_gain_coefficient": 0.23, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.68 SHGC 0.23 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.68, + "solar_heat_gain_coefficient": 0.23, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.63 SHGC 0.33 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.63, + "solar_heat_gain_coefficient": 0.33, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.63 SHGC 0.34 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.63, + "solar_heat_gain_coefficient": 0.34, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.63 SHGC 0.36 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.63, + "solar_heat_gain_coefficient": 0.36, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.63 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.63, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.83 SHGC 0.21 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.83, + "solar_heat_gain_coefficient": 0.21, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.32 SHGC 0.22 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.32, + "solar_heat_gain_coefficient": 0.22, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.83 SHGC 0.22 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.83, + "solar_heat_gain_coefficient": 0.22, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.83 SHGC 0.2 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.83, + "solar_heat_gain_coefficient": 0.2, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.6 SHGC 0.23 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.6, + "solar_heat_gain_coefficient": 0.23, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.62 SHGC 0.2 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.62, + "solar_heat_gain_coefficient": 0.2, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.22 SHGC 0.19 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.22, + "solar_heat_gain_coefficient": 0.19, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.22 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.22, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.22 SHGC 0.17 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.22, + "solar_heat_gain_coefficient": 0.17, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.22 SHGC 0.39 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.22, + "solar_heat_gain_coefficient": 0.39, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.98 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.98, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.98 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.98, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.57 SHGC 0.39 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.57, + "solar_heat_gain_coefficient": 0.39, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.46 SHGC 0.19 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.46, + "solar_heat_gain_coefficient": 0.19, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.98 SHGC 0.34 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.98, + "solar_heat_gain_coefficient": 0.34, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.22 SHGC 0.61 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.22, + "solar_heat_gain_coefficient": 0.61, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.22 SHGC 0.34 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.22, + "solar_heat_gain_coefficient": 0.34, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.57 SHGC 0.49 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.57, + "solar_heat_gain_coefficient": 0.49, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.46 SHGC 0.26 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.46, + "solar_heat_gain_coefficient": 0.26, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.98 SHGC 0.65 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.98, + "solar_heat_gain_coefficient": 0.65, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.58 SHGC 0.61 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.58, + "solar_heat_gain_coefficient": 0.61, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.46 SHGC 0.36 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.46, + "solar_heat_gain_coefficient": 0.36, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.46 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.46, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.35 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.35, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.98 SHGC 0.62 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.98, + "solar_heat_gain_coefficient": 0.62, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.58 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.58, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.75 SHGC 0.25 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.75, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.7 SHGC 0.25 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.7, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.98 SHGC 0.49 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.98, + "solar_heat_gain_coefficient": 0.49, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.65 SHGC 0.25 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.65, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.6 SHGC 0.25 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.6, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.9 SHGC 0.25 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.9, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.98 SHGC 0.71 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.98, + "solar_heat_gain_coefficient": 0.71, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.4 SHGC 0.4 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.4, + "solar_heat_gain_coefficient": 0.4, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.55 SHGC 0.4 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.55, + "solar_heat_gain_coefficient": 0.4, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.85 SHGC 0.4 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.85, + "solar_heat_gain_coefficient": 0.4, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.35 SHGC 0.4 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.35, + "solar_heat_gain_coefficient": 0.4, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.45 SHGC 0.4 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.45, + "solar_heat_gain_coefficient": 0.4, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.8 SHGC 0.4 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.8, + "solar_heat_gain_coefficient": 0.4, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.65 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.65, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.6 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.6, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.9 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.9, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.4 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.4, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.8 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.8, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.2 SHGC 0.25 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.2, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.98 SHGC 0.27 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.98, + "solar_heat_gain_coefficient": 0.27, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 1.17 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 1.17, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.98 SHGC 0.49 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.98, + "solar_heat_gain_coefficient": 0.49, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.98 SHGC 0.46 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.98, + "solar_heat_gain_coefficient": 0.46, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.58 SHGC 0.65 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.58, + "solar_heat_gain_coefficient": 0.65, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.58 SHGC 0.55 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.58, + "solar_heat_gain_coefficient": 0.55, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.4 SHGC 0.25 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.4, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.35 SHGC 0.25 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.35, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.55 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.55, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.42 SHGC 0.4 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.42, + "solar_heat_gain_coefficient": 0.4, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.77 SHGC 0.4 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.77, + "solar_heat_gain_coefficient": 0.4, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.81 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.81, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.32 SHGC 0.4 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.32, + "solar_heat_gain_coefficient": 0.4, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.7 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.7, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.59 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.59, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.44 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.44, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.93 SHGC 0.25 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.93, + "solar_heat_gain_coefficient": 0.25, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.75 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.75, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + }, + { + "name": "U 0.48 SHGC 0.45 Simple Glazing", + "material_type": "SimpleGlazing", + "roughness": null, + "thickness": null, + "conductivity": null, + "resistance": null, + "density": null, + "specific_heat": null, + "thermal_absorptance": null, + "solar_absorptance": null, + "visible_absorptance": null, + "gas_type": null, + "u_factor": 0.48, + "solar_heat_gain_coefficient": 0.45, + "visible_transmittance": null, + "optical_data_type": null, + "solar_transmittance_at_normal_incidence": null, + "front_side_solar_reflectance_at_normal_incidence": null, + "back_side_solar_reflectance_at_normal_incidence": null, + "visible_transmittance_at_normal_incidence": null, + "front_side_visible_reflectance_at_normal_incidence": null, + "back_side_visible_reflectance_at_normal_incidence": null, + "infrared_transmittance_at_normal_incidence": null, + "front_side_infrared_hemispherical_emissivity": null, + "back_side_infrared_hemispherical_emissivity": null, + "dirt_correction_factor_for_solar_and_visible_transmittance": null, + "solar_diffusing": null, + "frame_width": null, + "annotation": null + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/support_performance_curves.csv b/data/openstudio_standards_data/database_files/support_performance_curves.csv index 831e7d15c5..c4a7a9d817 100644 --- a/data/openstudio_standards_data/database_files/support_performance_curves.csv +++ b/data/openstudio_standards_data/database_files/support_performance_curves.csv @@ -7,9 +7,9 @@ Absor-2-Cap-fCHWT&ECT,2-StageAbsorptn,BiQuadratic,QRatio,CHWT,ECT,0.362073,0.000 Absor-2-HIR-fCHWT&ECT,2-StageAbsorptn,BiQuadratic,,CHWT,ECT,0.98675,0,0,-0.0234,0.00081,0,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 Absor-2-HIR-fPLR,2-StageAbsorptn,Quadratic,,PLR,,0.1355115,0.61798084,0.24651277,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 AHU-1_CoolCStandard10Ton_CapFF,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.77136,0.34053,-0.11088,,,,,,,,0.75918,1.13877,,,,,"From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" -AirCooled_Chiller_2004_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.0433811,0.0407077,0.0004506,-0.0041514,-0.0000886,-0.0003467,,,,,5,10,12.7,51.67,,,"Based on Dick Lord's study dated January 17, 2010." +AirCooled_Chiller_2004_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.0433811,0.0407077,0.0004506,-0.0041514,-8.86e-05,-0.0003467,,,,,5,10,12.7,51.67,,,"Based on Dick Lord's study dated January 17, 2010." AirCooled_Chiller_2004_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.5961915,-0.0099496,0.0007888,0.0004506,0.0004875,-0.0007623,,,,,5,10,12.7,51.67,,,"Based on Dick Lord's study dated January 17, 2010." -AirCooled_Chiller_2010_PathA_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.0433825,0.0407073,0.0004506,-0.0041514,-0.0000886,-0.0003467,,,,,5,10,12.7,51.67,,,"Based on Dick Lord's study dated January 17, 2010." +AirCooled_Chiller_2010_PathA_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.0433825,0.0407073,0.0004506,-0.0041514,-8.86e-05,-0.0003467,,,,,5,10,12.7,51.67,,,"Based on Dick Lord's study dated January 17, 2010." AirCooled_Chiller_2010_PathA_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.5961915,-0.0099496,0.0007888,0.0004506,0.0004875,-0.0007623,,,,,5,10,12.7,51.67,,,"Based on Dick Lord's study dated January 17, 2010." AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.141,0.655,0.203,,,,,,,,0,1,,,,,"Based on Dick Lord's study dated January 17, 2010. EIRFPLR curve is identical for all AirCooled Chillers" AirCooled_Chiller_GT150_2004_EIRFPLR,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.141,0.655,0.203,,,,,,,,0,1,,,,,"Based on Dick Lord's study dated January 17, 2010." @@ -24,8 +24,8 @@ Boiler with Minimum Turndown,Boiler,Cubic,FIRRatio,QRatio,,0.7791,1.4745,-2.5795 Boiler with No Minimum Turndown,Boiler,Cubic,FIRRatio,QRatio,,0.7463,1.3196,-2.2154,1.1674,,,,,,,0,1.3,,,,,From Regression of Prototype Building EMS BOILER-EFFFPLR-NECB2011,Boiler,Cubic,FIRRatio,QRatio,,0.2901,2.6664,-3.764,1.82,,,,,,,0,1,,,,,From NECB 2011 CdTe_Spectral-fAirMass,PV-Module,Cubic,,AirMass,,0.93700588,0.05130703,-0.00646639,0.00017267,,,,,,,,,,,,,From .dat files included with MASControl2 -CentChlrAirCoolCap-fCHW&OAT,Chiller,BiQuadratic,QRatio,CHWT,OAT,0.94533053,0.068473818,-0.003361694,0.000108108,-0.000225,0.000082,,,,,,,,,,,From .dat files included with MASControl2 -CentChlrAirCoolEIR-fCHW&OAT,Chiller,BiQuadratic,EIRRatio,CHWT,OAT,0.47343824,0.015708042,-0.000948,0.012260718,0.0000955,-0.000352,,,,,,,,,,,From .dat files included with MASControl2 +CentChlrAirCoolCap-fCHW&OAT,Chiller,BiQuadratic,QRatio,CHWT,OAT,0.94533053,0.068473818,-0.003361694,0.000108108,-0.000225,8.2e-05,,,,,,,,,,,From .dat files included with MASControl2 +CentChlrAirCoolEIR-fCHW&OAT,Chiller,BiQuadratic,EIRRatio,CHWT,OAT,0.47343824,0.015708042,-0.000948,0.012260718,9.55e-05,-0.000352,,,,,,,,,,,From .dat files included with MASControl2 CentChlrAirCoolEIR-fPLR,Chiller,Quadratic,EIRRatio,PLR,,0.24258,0.41468,0.34273973,,,,,,,,,,,,,,From .dat files included with MASControl2 CentH2O-Cap-fCHWT&ECT,HermCentrifugal,BiQuadratic,QRatio,CHWT,ECT,0.36460761,-0.030523554,-0.001929776,0.066367926,-0.001891966,0.003110627,,,,,,,,,,,From .dat files included with MASControl2 CentH2O-EIR-fCHWT&ECT,HermCentrifugal,BiQuadratic,EIRRatio,CHWT,ECT,0.65868459,-0.025336458,0.000991,0.01280322,0.000171,-0.000301,,,,,,,,,,,From .dat files included with MASControl2 @@ -33,38 +33,38 @@ CentH2O-EIR-fPLR&dT,HermCentrifugal,BiQuadratic,EIRRatio,PLR,dT,0.27969646,0.573 CentH2OVSD-Cap-fCHWT&ECT,HermCentrifugal,BiQuadratic,QRatio,CHWT,ECT,0.36211013,-0.032249754,-0.000886,0.066743838,-0.001731488,0.002180358,,,,,,,,,,,From .dat files included with MASControl2 CentH2OVSD-EIR-fCHWT&ECT,HermCentrifugal,BiQuadratic,EIRRatio,CHWT,ECT,0.41386133,-0.088037676,0.00098,0.056770308,-0.000946,0.001418731,,,,,,,,,,,From .dat files included with MASControl2 CentH2OVSD-EIR-fPLR&dT,HermCentrifugal,BiQuadratic,EIRRatio,PLR,dT,0.14703037,-0.00349667,1.01161313,-0.006474546,0.00088,-0.020960478,,,,,,,,,,,From .dat files included with MASControl2 -ChillerCentCapFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.7446451,0.0114858,0.0000148,0.022401,-0.000688,0.0009839,,,,,5,10,24,35,,,From Dick Lord's Chiller Model study for ASHRAE 2007 baseline -ChillerCentEIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.772877,0.022101,-0.0000799,-0.0070045,0.0004763,-0.0010612,,,,,5,10,24,35,,,From Dick Lord's Chiller Model study for ASHRAE 2007 baseline -ChillerCentEIRPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,From Dick Lord's Chiller Model study for ASHRAE 2007 baseline +ChillerCentCapFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.7446451,0.0114858,1.48e-05,0.022401,-0.000688,0.0009839,,,,,5,10,24,35,,,From Dick Lord's Chiller Model study for ASHRAE 2007 baseline +ChillerCentEIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.772877,0.022101,-7.99e-05,-0.0070045,0.0004763,-0.0010612,,,,,5,10,24,35,,,From Dick Lord's Chiller Model study for ASHRAE 2007 baseline +ChillerCentEIRPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,From Dick Lord's Chiller Model study for ASHRAE 2007 baseline ChlrAirRecipEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.114437,0.545933,0.342299,,,,,,,,0,1,,,0.11,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx ChlrAirRecipEIRRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.542784,-0.013907,0.000476,0.012197,0.000149,-0.000334,,,,,4.44,12.22,23.89,46.11,0.72,1.3,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrAirRecipQRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.12603,0.041571,0.000253,-0.010526,0.00001,-0.000256,,,,,4.44,12.22,23.89,46.11,0.82,1.3,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrAirRecipQRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.12603,0.041571,0.000253,-0.010526,1e-05,-0.000256,,,,,4.44,12.22,23.89,46.11,0.82,1.3,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx ChlrAirScrewEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.036487,0.734743,0.219947,,,,,,,,0,1,,,0.04,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrAirScrewEIRRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.570624,0.011954,-0.000522,-0.000032,0.000421,-0.000606,,,,,4.44,12.22,23.89,46.11,0.7,1.38,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrAirScrewQRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.985959,0.049487,-0.000298,-0.003737,-0.000045,-0.000502,,,,,4.44,12.22,23.89,46.11,0.82,1.3,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrAirScrewEIRRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.570624,0.011954,-0.000522,-3.2e-05,0.000421,-0.000606,,,,,4.44,12.22,23.89,46.11,0.7,1.38,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrAirScrewQRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.985959,0.049487,-0.000298,-0.003737,-4.5e-05,-0.000502,,,,,4.44,12.22,23.89,46.11,0.82,1.3,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx ChlrAirScrollEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.063691,0.584888,0.352803,,,,,,,,0,1,,,0.06,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx ChlrAirScrollEIRRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.702194,-0.004466,0.000535,-0.005506,0.000544,-0.000729,,,,,4.44,12.22,23.89,46.11,0.69,1.45,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrAirScrollQRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.02138,0.037021,0.000233,-0.003893,-0.000065,-0.000269,,,,,4.44,12.22,23.89,46.11,0.82,1.3,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrHPAirCoolCap-fCHW&OAT,Chiller,BiQuadratic,QRatio,CHWT,OAT,1.13076899,0.03157983,0.000358,-0.009856332,0.0000101,-0.00015,,,,,,,,,,,From .dat files included with MASControl2 +ChlrAirScrollQRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.02138,0.037021,0.000233,-0.003893,-6.5e-05,-0.000269,,,,,4.44,12.22,23.89,46.11,0.82,1.3,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrHPAirCoolCap-fCHW&OAT,Chiller,BiQuadratic,QRatio,CHWT,OAT,1.13076899,0.03157983,0.000358,-0.009856332,1.01e-05,-0.00015,,,,,,,,,,,From .dat files included with MASControl2 ChlrHPAirCoolEIR-fCHW&OAT,Chiller,BiQuadratic,EIRRatio,CHWT,OAT,0.5637406,-0.009225918,0.000353,0.009452178,0.000187,-0.000314,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPAirHeatCap-fHW&39-,Chiller,BiQuadratic,QRatio,HW,39,0.92141508,-0.003413682,-0.00000386,0.0324,0.000611,-0.0000518,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPAirHeatCap-fHW&39+,Chiller,BiQuadratic,QRatio,HW,39+,0.94069023,-0.004035888,0.000000421,0.046218906,-0.001703171,-0.000000227,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPAirHeatEIR-fHW&39-,Chiller,BiQuadratic,EIRRatio,HW,39,0.33398382,0.019817694,0.000012,0.0048024,-0.0000332,-0.000898,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPAirHeatEIR-fHW&39+,Chiller,BiQuadratic,EIRRatio,HW,39+,0.38886863,0.018107262,0.0000194,-0.026683668,0.002056655,-0.000499,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPAirHeatCap-fHW&39-,Chiller,BiQuadratic,QRatio,HW,39,0.92141508,-0.003413682,-3.86e-06,0.0324,0.000611,-5.18e-05,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPAirHeatCap-fHW&39+,Chiller,BiQuadratic,QRatio,HW,39+,0.94069023,-0.004035888,4.21e-07,0.046218906,-0.001703171,-2.27e-07,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPAirHeatEIR-fHW&39-,Chiller,BiQuadratic,EIRRatio,HW,39,0.33398382,0.019817694,1.2e-05,0.0048024,-3.32e-05,-0.000898,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPAirHeatEIR-fHW&39+,Chiller,BiQuadratic,EIRRatio,HW,39+,0.38886863,0.018107262,1.94e-05,-0.026683668,0.002056655,-0.000499,,,,,,,,,,,From .dat files included with MASControl2 ChlrHPH2OCoolCap_fCHW&ECT,Chiller/HP,BiQuadratic,QRatio,CHWT,ECT,35.68362061,0.62273101,-0.005677932,-0.248948775,-0.003461286,0.011142622,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPH2OCoolCap_fCHW&ECT-Old,Chiller/HP,BiQuadratic,QRatio,CHWT,ECT,0.96601399,0.04050054,0.000589,-0.008098668,0.0000665,-0.000454,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPH2OCoolCap_fCHW&ECT-Old,Chiller/HP,BiQuadratic,QRatio,CHWT,ECT,0.96601399,0.04050054,0.000589,-0.008098668,6.65e-05,-0.000454,,,,,,,,,,,From .dat files included with MASControl2 ChlrHPH2OCoolEIR_fCHW&ECT,Chiller/HP,BiQuadratic,EIRRatio,CHWT,ECT,0.111287472,-0.002094557,0.000201,0.00170532,0.000168,-0.000308,,,,,,,,,,,From .dat files included with MASControl2 ChlrHPH2OCoolEIR_fCHW&ECT-Old,Chiller/HP,BiQuadratic,EIRRatio,CHWT,ECT,0.61092869,-0.016352352,0.000407,0.003044232,0.000592,-0.000668,,,,,,,,,,,From .dat files included with MASControl2 ChlrHPH2OHeatCap_fHWS&EET,Chiller/HP,BiQuadratic,QRatio,HWS,EET,29.914016,0.1544256,-0.0041472,0.6832512,-0.00203148,0.00199584,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPH2OHeatCap_fHWS&EET-Old,Chiller/HP,BiQuadratic,QRatio,HWS,EET,0.84649612,-0.00264807,0.0000231,0.02700126,0.00013,-0.000127,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPH2OHeatEIR_fHWS&EET,Chiller/HP,BiQuadratic,EIRRatio,HWS,EET,0.12004,-0.00011232,0.0000985,-0.00107928,0.0000732,-0.000134,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPH2OHeatCap_fHWS&EET-Old,Chiller/HP,BiQuadratic,QRatio,HWS,EET,0.84649612,-0.00264807,2.31e-05,0.02700126,0.00013,-0.000127,,,,,,,,,,,From .dat files included with MASControl2 +ChlrHPH2OHeatEIR_fHWS&EET,Chiller/HP,BiQuadratic,EIRRatio,HWS,EET,0.12004,-0.00011232,9.85e-05,-0.00107928,7.32e-05,-0.000134,,,,,,,,,,,From .dat files included with MASControl2 ChlrHPH2OHeatEIR_fHWS&EET-Old,Chiller/HP,BiQuadratic,EIRRatio,HWS,EET,0.2068226,0.018812142,0.000105,-0.012659724,0.000406,-0.000399,,,,,,,,,,,From .dat files included with MASControl2 ChlrWtrCentPathAAllEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.222149,0.503156,0.256905,,,,,,,,0.1,1,,,0.28,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx ChlrWtrCentPathAAllEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.658643,-0.025339,0.000991,0.012801,0.000171,-0.000301,,,,,4.44,12.22,15.56,29.44,0.68,1.05,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx ChlrWtrCentPathAAllQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.364691,-0.030521,-0.00193,0.066374,-0.001892,0.003111,,,,,4.44,12.22,15.56,29.44,0.87,0.91,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx ChlrWtrCentPathBGtEql300Lt600tonEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.055483,0.451866,0.488242,,,,,,,,0.1,1,,,0.11,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx ChlrWtrCentPathBGtEql300Lt600tonEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.756376,-0.015019,0.000156,0.00246,0.000515,-0.000687,,,,,4.44,12.22,15.56,29.44,0.63,1.12,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrCentPathBGtEql300Lt600tonQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,1.35608,0.04875,-0.000888,-0.014525,-0.000286,-0.00004,,,,,4.44,12.22,15.56,29.44,0.87,1.52,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrCentPathBGtEql300Lt600tonQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,1.35608,0.04875,-0.000888,-0.014525,-0.000286,-4e-05,,,,,4.44,12.22,15.56,29.44,0.87,1.52,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx ChlrWtrCentPathBGtEql600tonEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.107426,0.156775,0.739345,,,,,,,,0.1,1,,,0.13,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx ChlrWtrCentPathBGtEql600tonEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.737625,0.001456,-0.000223,0.007116,0.000267,-0.000735,,,,,4.44,12.22,15.56,29.44,0.76,1.08,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx ChlrWtrCentPathBGtEql600tonQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.854454,0.042526,-0.000185,0.011697,-0.000497,-0.000412,,,,,4.44,12.22,15.56,29.44,0.9,1.33,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx @@ -73,22 +73,22 @@ ChlrWtrCentPathBLt300tonEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRati ChlrWtrCentPathBLt300tonQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,1.15508,0.036503,-0.000499,-0.001455,-0.000439,-0.000172,,,,,4.44,12.22,15.56,29.44,0.86,1.37,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.310965,0.322519,0.372745,,,,,,,,0.1,1,,,0.35,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.665307,-0.009339,0.000483,0.009492,0.000544,-0.000864,,,,,4.44,12.22,15.56,29.44,0.74,1.27,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.96744,0.037082,0.000434,-0.005837,-0.000049,-0.000274,,,,,4.44,12.22,15.56,29.44,0.89,1.33,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.96744,0.037082,0.000434,-0.005837,-4.9e-05,-0.000274,,,,,4.44,12.22,15.56,29.44,0.89,1.33,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx ChlrWtrPosDispPathBAllEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0,0.6206,0.3893,,,,,,,,0.1,1,,,0.07,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx ChlrWtrPosDispPathBAllEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.428265,-0.024071,0.000849,0.016416,0.000381,-0.00059,,,,,4.44,12.22,15.56,29.44,0.5,1.07,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrPosDispPathBAllQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.899926,0.030102,-0.000332,-0.001743,-0.000092,0.000229,,,,,4.44,12.22,15.56,29.44,0.93,1.21,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +ChlrWtrPosDispPathBAllQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.899926,0.030102,-0.000332,-0.001743,-9.2e-05,0.000229,,,,,4.44,12.22,15.56,29.44,0.93,1.21,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx CHW-Coil-Cap-fAirflow,CHWCoils,Quadratic,QRatio,Airflow,,0.0488,1.38,-0.425,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -CHW-Coil-Cap-fEWB&EWT,CHWCoils,BiQuadratic,QRatio,EWB,EWT,1.6726784,-0.13378464,0.0065124,0.03828096,0.0000826,-0.005868936,,,,,15.55556,29.44444,4.44444,18.33333,,,From .dat files included with MASControl2 +CHW-Coil-Cap-fEWB&EWT,CHWCoils,BiQuadratic,QRatio,EWB,EWT,1.6726784,-0.13378464,0.0065124,0.03828096,8.26e-05,-0.005868936,,,,,15.55556,29.44444,4.44444,18.33333,,,From .dat files included with MASControl2 CHW-Coil-Cap-fFluidFlow,CHWCoils,Quadratic,QRatio,FluidFlow,,0.218,3199.5088,-3280000,,,,,,,,0,1,,,,,From .dat files included with MASControl2 -Coffin Defrost Curve,Refrigerated Case,Cubic,,,,0.3475,0.0296,0.0007,0.00003,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings -Coffin Latent Curve,Refrigerated Case,Cubic,,,,0.3379,0.0309,0.0005,0.00004,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings +Coffin Defrost Curve,Refrigerated Case,Cubic,,,,0.3475,0.0296,0.0007,3e-05,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings +Coffin Latent Curve,Refrigerated Case,Cubic,,,,0.3379,0.0309,0.0005,4e-05,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings COIL-BF-FFLOW-SPEC,CoilBF-FFLOW,Linear,,Flow,,0.33,1419.6496,,,,,,,,,,,,,0.8,,From .dat files included with MASControl2 Coil-Bypass-Factor-fPLR,CHWCoils,Linear,QRatio,PLR,,1,0,,,,,,,,,,,,,,,From .dat files included with MASControl2 CoilClgDXDblEIRRatio_fCFMRatio,DX Cooling Coil,Cubic,EIRRatio,FlowRatio,,1.007948,0.345441,-0.692289,0.338899,,,,,,,0,1,,,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx CoilClgDXDblQRatio_fCFMRatio,DX Cooling Coil,Cubic,QRatio,FlowRatio,,0.472786,1.243342,-1.038706,0.322578,,,,,,,-100,100,0.47,,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx CoilClgDXEIRRatio_fQFrac,DX Cooling Coil,Cubic,EIRRatio,QRatio,,0,5.1091,-8.5515,4.4744,,,,,,,0.7,1,0.92,1,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx CoilClgDXEIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.116709,0.028458,-0.000411,0.021422,0.000162,-0.00068,,,,,13.89,25,23.89,46.11,0.77,1.33,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgDXQRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.86779,0.014245,0.000554,-0.007569,0.000032,-0.000191,,,,,13.89,25,23.89,46.11,0.77,1.29,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgDXQRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.86779,0.014245,0.000554,-0.007569,3.2e-05,-0.000191,,,,,13.89,25,23.89,46.11,0.77,1.29,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx CoilClgDXSEER13EER11EIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,-0.199992,-0.035686,0.000787,0.074834,-0.000516,-0.000573,,,,,13.89,25,23.89,46.11,0.55,1.44,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx CoilClgDXSEER15EER11EIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,-1.790474,-0.028777,0.000763,0.153391,-0.001482,-0.000721,,,,,13.89,25,23.89,46.11,0.35,1.42,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx CoilClgDXSEER16EER13EIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.686684,-0.035826,0.000781,0.025564,0.000163,-0.000559,,,,,13.89,25,23.89,46.11,0.65,1.51,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx @@ -100,13 +100,13 @@ CoilClgDXSnglEIRRatio_fCFMRatio,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1. CoilClgDXSnglQRatio_fCFMRatio,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx CoilClgPTACEIRRatio_fQFrac,DX Cooling Coil,Cubic,EIRRatio,QRatio,,0.85,0.15,0,0,,,,,,,0.7,1,0.96,1,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx CoilClgPTACEIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.341434,0.03481,-0.000625,0.004941,0.000437,-0.000729,,,,,13.89,25,23.89,46.11,0.75,1.4,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgPTACQRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.942879,0.009538,0.000684,-0.011002,0.000006,-0.00001,,,,,13.89,25,23.89,46.11,0.71,1.34,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx +CoilClgPTACQRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.942879,0.009538,0.000684,-0.011002,6e-06,-1e-05,,,,,13.89,25,23.89,46.11,0.71,1.34,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx ConstantCubic,,Cubic,,,,1,0,0,0,,,,,,,-100,100,,,,,From Reference Buildings Cool-PLF-fPLR,DX Cooling Coil,Quadratic,EIRRatio,QRatio,,0.90949556,0.09864773,-0.00819488,,,,,,,,0,1,,,,,From PNNL Prototype FullServiceRestaurant CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.2055,-0.32953,0.12308,,,,,,,,0.75918,1.13877,,,,,"From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" -Curve_Biquadratic_CBES_01,,BiQuadratic,,,,0.86779,0.014245,0.000554,-0.007569,0.000032,-0.000191,,,,,0,100,0,100,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov +Curve_Biquadratic_CBES_01,,BiQuadratic,,,,0.86779,0.014245,0.000554,-0.007569,3.2e-05,-0.000191,,,,,0,100,0,100,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov Curve_Biquadratic_CBES_02,,BiQuadratic,,,,-0.199992,-0.035686,0.000787,0.074834,-0.000516,-0.000573,,,,,13.9,25,23.9,43.3,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov -Curve_Biquadratic_CBES_03,,BiQuadratic,,,,0.9425878,0.00954335,0.00068377,-0.0110427,0.00000525,-0.00000972,,,,,17,22,13,46,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov +Curve_Biquadratic_CBES_03,,BiQuadratic,,,,0.9425878,0.00954335,0.00068377,-0.0110427,5.25e-06,-9.72e-06,,,,,17,22,13,46,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov Curve_Biquadratic_CBES_04,,BiQuadratic,,,,0.3424144,0.03488501,-0.0006237,0.00497722,0.00043795,-0.000728,,,,,17,22,13,46,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov Curve_Quadratic_CBES_01,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov Curve_Quadratic_CBES_02,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.156,-0.1816,0.0256,,,,,,,,0.5,1.5,,,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov @@ -115,10 +115,10 @@ Curve_Quadratic_CBES_04,,Quadratic,,,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,,From Commerci Curve_Quadratic_CBES_05,,Quadratic,,,,1.1552,-0.1808,0.0256,,,,,,,,0.5,1.5,,,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov Curve_Quadratic_CBES_06,,Quadratic,,,,0.85,0.15,0,,,,,,,,0,1,,,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov DEER DHW HIR-FPLR Curve,DEERDHWHIR-FPLR,Linear,,PLR,,0,1,,,,,,,,,,,,,,,From .dat files included with MASControl2 -DEER_defrost,Refrigeration,Cubic,,,,0.023632,0.0006232,0.00002832,4.4035E-07,,,,,,,-23,7,,,,, +DEER_defrost,Refrigeration,Cubic,,,,0.023632,0.0006232,2.832e-05,4.4035e-07,,,,,,,-23,7,,,,, DEER_Heat_Rejections_LT,Refrigeration,Linear,Capacity,DeltaT,,0,16383.61446,,,,,,,,,-100,100,,,,,From eQuest Grocery store model DEER_Heat_Rejections_MT,Refrigeration,Linear,Capacity,DeltaT,,0,20626.34211,,,,,,,,,-100,100,,,,,From eQuest Grocery store model -Default_Case_Latent_Cedit_Curve,Refrigeration,Cubic,,,,0.026526281,0.001078032,-6.02558E-05,1.23732E-06,,,,,,,-35,20,,,,, +Default_Case_Latent_Cedit_Curve,Refrigeration,Cubic,,,,0.026526281,0.001078032,-6.02558e-05,1.23732e-06,,,,,,,-35,20,,,,, Defrost-ResisDem-Frac-fOWB&ODB,DXCool/Heat,BiLinear,QRatio,OWB,ODB,0.0333,0,0,,,,,,,,-23.333,29.444,-23.333,29.444,,,From .dat files included with MASControl2 Defrost-ResisTime-Frac-fOWB&ODB,DXCool/Heat,BiLinear,QRatio,OWB,ODB,0.0333,0,0,,,,,,,,-23.333,29.444,-23.333,29.444,,,From .dat files included with MASControl2 Defrost-ReversDem-Frac-fOWB&ODB,DXCool/Heat,BiLinear,QRatio,OWB,ODB,0.0333,0,0,,,,,,,,-23.333,29.444,-23.333,29.444,,,From .dat files included with MASControl2 @@ -127,7 +127,7 @@ Desc-Gas-fT&W,Desiccant,BiQuadratic,,T,W,18784.36736,-3209.524992,-11.8830564,38 Desc-HR8-fWB1&WB6,Desiccant,BiQuadratic,,WB1,WB6,-0.27680768,0.071770464,0.000735,0.145668672,0.000591,-0.002648246,,,,,12.77778,46.11111,12.77778,46.11111,,,From .dat files included with MASControl2 Desc-HR8PL-fWB1&WB6,Desiccant,BiQuadratic,,WB1,WB6,-0.05234208,0.076111488,0.000502,0.11464641,0.001235315,-0.002453879,,,,,12.77778,46.11111,12.77778,46.11111,,,From .dat files included with MASControl2 Desc-kW-fT&W,Desiccant,BiQuadratic,,T,W,3.33024,-0.010674,0,0.00404,0,0,,,,,7.22222,46.11111,0,0.1,,,From .dat files included with MASControl2 -Desc-QREG-fWB1&WB6,Desiccant,BiQuadratic,,WB1,WB6,80.58068736,-0.627217344,0.0170748,-2.186211312,0.0000437,0.018960674,,,,,12.77778,40.55556,12.77778,46.11111,,,From .dat files included with MASControl2 +Desc-QREG-fWB1&WB6,Desiccant,BiQuadratic,,WB1,WB6,80.58068736,-0.627217344,0.0170748,-2.186211312,4.37e-05,0.018960674,,,,,12.77778,40.55556,12.77778,46.11111,,,From .dat files included with MASControl2 Desc-QREGPL-fWB1&WB6,Desiccant,BiQuadratic,,WB1,WB6,20.30901408,-0.159663744,0.0046008,-0.586622934,-0.00024,0.005206064,,,,,12.77778,46.11111,12.77778,46.11111,,,From .dat files included with MASControl2 Desc-T-fT&W,Desiccant,BiQuadratic,,T,W,31.53328,1.0173168,-0.0033372,0.295,-0.00017,-0.0015696,,,,,7.22222,46.11111,0,0.1,,,From .dat files included with MASControl2 Desc-T8-fWB1&WB6,Desiccant,BiLinear,,WB1,WB6,34.64,1.6236,0.2574,,,,,,,,12.77778,46.11111,12.77778,46.11111,,,From .dat files included with MASControl2 @@ -135,7 +135,7 @@ Desc-T8PL-fWB1&WB6,Desiccant,BiLinear,,WB1,WB6,32.7692,1.7496,0.06588,,,,,,,,12. Desc-W-fT&W,Desiccant,BiQuadratic,,T,W,7.82704,0.119376,0.0144504,0.0831,0.000697,0.002862,,,,,7.22222,46.11111,0,0.1,,,From .dat files included with MASControl2 Direct-Effectiveness-fFlow,EvapCooler,Quadratic,,Flow,,1.18,-546.67104,333000,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 DOE Ref DX Clg Coil Cool-CAP-fFlow,DX Cooling Coil,Cubic,QRatio,FlowRatio,,1,0,0,0,,,,,,,-100,100,,,,,From DOE Pre-1980 Reference Building -DOE Ref DX Clg Coil Cool-Cap-fT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.9712123,-0.015275502,0.001443452,-0.00039321,-6.8364E-06,-0.000290596,,,,,-100,100,-100,100,,,From DOE Pre-1980 Reference Building +DOE Ref DX Clg Coil Cool-Cap-fT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.9712123,-0.015275502,0.001443452,-0.00039321,-6.8364e-06,-0.000290596,,,,,-100,100,-100,100,,,From DOE Pre-1980 Reference Building DOE Ref DX Clg Coil Cool-EIR-fFlow,DX Cooling Coil,Cubic,EIRRatio,FlowRatio,,1,0,0,0,,,,,,,-100,100,,,,,From DOE Pre-1980 Reference Building DOE Ref DX Clg Coil Cool-EIR-fT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.28687133,0.023902164,-0.000810648,0.013458546,0.000338936,-0.000487004,,,,,-100,100,-100,100,,,From DOE Pre-1980 Reference Building DOE Ref DX Clg Coil Cool-PLF-fPLR,DX Cooling Coil,Quadratic,EIRRatio,QRatio,,0.90949556,0.09864773,-0.00819488,,,,,,,,0,1,,,,, @@ -148,10 +148,10 @@ DW-HeatPump-EIR-fPLR,HeatPumpDW-Heat,Cubic,EIRRatio,PLR,,0.08565215,0.93881371,- DW-HeatPump-EIR-fSupplyT&EDB,HeatPumpDW-Heat,BiQuadratic,EIRRatio,SupplyT,EDB,1.25311702,0,0,-0.033921486,0.000426,0,,,,,,,,,,,From .dat files included with MASControl2 DX Coil Cap-FF,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,,"From PNNL Prototype Buildings ApartmentMidRise, HotelSmall, OfficeSmall, RetailStandAlone, RetailStripmall, SchoolPrimary, Warehouse" DX-Bypass-Factor-fAirflow,DXCool/Heat,Quadratic,QRatio,Airflow,,-0.2542341,1.2182557,0.03597841,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -DX-Bypass-Factor-fEWB&EDB,DXCool/Heat,BiQuadratic,QRatio,EWB,EDB,0.8463094,0.014259096,0.000184,-0.014791716,-0.00000548,0.000487,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +DX-Bypass-Factor-fEWB&EDB,DXCool/Heat,BiQuadratic,QRatio,EWB,EDB,0.8463094,0.014259096,0.000184,-0.014791716,-5.48e-06,0.000487,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 DX-Bypass-Factor-fPLR,DXCool/Heat,Linear,QRatio,PLR,,1,0,,,,,,,,,,,,,,,From .dat files included with MASControl2 DX-Cap-fAirflow,DXCool/Heat,Cubic,QRatio,Airflow,,0.06429396,1.99755645,-1.44277024,0.38091758,,,,,,,,,,,,,From .dat files included with MASControl2 -DX-Cool-Cap-fEWB&OAT,DXCool/Heat,BiQuadratic,QRatio,EWB,OAT,0.86791562,0.014247648,0.000554,-0.007558056,0.000033,-0.000192,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +DX-Cool-Cap-fEWB&OAT,DXCool/Heat,BiQuadratic,QRatio,EWB,OAT,0.86791562,0.014247648,0.000554,-0.007558056,3.3e-05,-0.000192,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 DX-Cool-Cap-fRPM&OAT,DXCool/Heat,BiQuadratic,QRatio,RPM,OAT,32,9.549296596,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 DX-Cool-CondFan-fPLR&OAT,DXCool/Heat,BiQuadratic,PwrRatio,PLR,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 DX-Cool-CycleLoss-fPLR,DXCool/Heat,Linear,QRatio,PLR,,0.7,0.3,,,,,,,,,,,,,,,From .dat files included with MASControl2 @@ -160,7 +160,7 @@ DX-Cool-EIR-fPLR,DXCool/Heat,Cubic,EIRRatio,PLR,,0.201,-0.0312,1.95,-1.12,,,,,,, DX-Cool-EIR-fRPM&OAT,DXCool/Heat,BiQuadratic,EIRRatio,RPM,OAT,32,9.549296596,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 DX-Cool-Waste-Heat-fEWB&OAT,DXCool/Heat,BiLinear,QRatio,EWB,OAT,1,0,0,,,,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 DX-Cool-Waste-Heat-fRPM&OAT,DXCool/Heat,BiQuadratic,QRatio,RPM,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 -DX-Heat-Cap-fEDB&OAT,DXCool/Heat,BiQuadratic,QRatio,EDB,OAT,0.7422592,0,0,0.030682602,0.0000323,0,,,,,12.77778,29.44444,-12.22222,29.44444,,,From .dat files included with MASControl2 +DX-Heat-Cap-fEDB&OAT,DXCool/Heat,BiQuadratic,QRatio,EDB,OAT,0.7422592,0,0,0.030682602,3.23e-05,0,,,,,12.77778,29.44444,-12.22222,29.44444,,,From .dat files included with MASControl2 DX-Heat-Cap-fRPM&OAT,DXCool/Heat,BiQuadratic,QRatio,RPM,OAT,32,9.549296596,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 DX-Heat-CondFan-fPLR&OAT,DXCool/Heat,BiQuadratic,PwrRatio,PLR,OAT,1,0,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 DX-Heat-CycleLoss-fPLR,DXCool/Heat,Linear,QRatio,PLR,,0.75,0.25,,,,,,,,,,,,,,,From .dat files included with MASControl2 @@ -170,25 +170,25 @@ DX-Heat-EIR-fRPM&OAT,DXCool/Heat,BiQuadratic,EIRRatio,RPM,OAT,32,9.549296596,0,0 DX-Heat-Waste-Heat-fEDB&OAT,DXCool/Heat,BiLinear,QRatio,EDB,OAT,1,0,0,,,,,,,,12.77778,29.44444,-12.22222,29.44444,,,From .dat files included with MASControl2 DX-Heat-Waste-Heat-fRPM&OAT,DXCool/Heat,BiQuadratic,QRatio,RPM,OAT,1,0,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 DX-Sens-Cap-fAirflow,DXCool/Heat,Cubic,QRatio,Airflow,,0.34465606,0.89289891,-0.3554498,0.1178948,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -DX-Sens-Cap-fEWB&OAT,DXCool/Heat,BiQuadratic,QRatio,EWB,OAT,2.93224448,-0.09445968,0.0002,-0.007176816,0.0000103,0.000109,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +DX-Sens-Cap-fEWB&OAT,DXCool/Heat,BiQuadratic,QRatio,EWB,OAT,2.93224448,-0.09445968,0.0002,-0.007176816,1.03e-05,0.000109,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 DXCOOL-NECB2011-REF-CAPFFLOW,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,1,0,0,,,,,,,,0,1,,,,,From NECB 2011 -DXCOOL-NECB2011-REF-CAPFT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.867905,0.0142459,0.00055436,-0.0075575,0.000033,-0.0001918,,,,,13,24,24,46,,,From NECB 2011 +DXCOOL-NECB2011-REF-CAPFT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.867905,0.0142459,0.00055436,-0.0075575,3.3e-05,-0.0001918,,,,,13,24,24,46,,,From NECB 2011 DXCOOL-NECB2011-REF-COOLEIRFFLOW,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1,0,0,,,,,,,,0,1,,,,,From NECB 2011 DXCOOL-NECB2011-REF-COOLEIRFT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.116936,0.0284933,-0.0004112,0.0214108,0.00016103,-0.0006791,,,,,13,24,24,46,,,From NECB 2011 DXCOOL-NECB2011-REF-COOLPLFFPLR,DX Cooling Coil,Cubic,EIRRatio,QRatio,,0.0277,4.9151,-8.184,4.2702,,,,,,,0.7,1,,,,,"From NECB, curve modified to take into account how PLF is used in E+, and PLF ranges (> 0.7)" DXHEAT-NECB2011-REF-CAPFFLOW,DX Heating Coil,Cubic,QRatio,FlowRatio,,0.84,0.16,0,0,,,,,,,0.5,1.5,,,,,From NECB 2011 -DXHEAT-NECB2011-REF-CAPFT,DX Heating Coil,Cubic,QRatio,Toadb,,0.729,0.0319,0.000136,-0.00000875,,,,,,,-20,20,,,,,From NECB 2011 +DXHEAT-NECB2011-REF-CAPFT,DX Heating Coil,Cubic,QRatio,Toadb,,0.729,0.0319,0.000136,-8.75e-06,,,,,,,-20,20,,,,,From NECB 2011 DXHEAT-NECB2011-REF-EIRFFLOW,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.3824,-0.4336,0.0512,,,,,,,,0,1,,,,,From NECB 2011 -DXHEAT-NECB2011-REF-EIRFT,DX Heating Coil,Cubic,EIRRatio,Toadb,,1.2183,-0.03612,0.00142,-0.0000268,,,,,,,-20,20,,,,,From NECB 2011 +DXHEAT-NECB2011-REF-EIRFT,DX Heating Coil,Cubic,EIRRatio,Toadb,,1.2183,-0.03612,0.00142,-2.68e-05,,,,,,,-20,20,,,,,From NECB 2011 DXHEAT-NECB2011-REF-PLFFPLR,DX Heating Coil,Cubic,EIRRatio,QRatio,,0.3696,2.3362,-2.9577,1.2596,,,,,,,0.7,1,,,,,From NECB 2011 Minisplit-Heat-Cap-fT,DX Heating Coil,BiQuadratic,QRatio,Tiadb,Toadb,1.14715889,-0.010386676,0,0.008653846,0,0,,,,,-100,100,-100,100,,,From OpenStudio-HPXML Minisplit-Heat-Cap-fFF,DX Heating Coil,Quadratic,QRatio,Tiadb,Toadb,1,0,0,,,,,,,,0,2,0,2,,,From OpenStudio-HPXML -Minisplit-Heat-EIR-fT,DX Heating Coil,BiQuadratic,EIRRatio,Tiadb,Toadb,0.99999417,0.004684594,5.90129E-05,-0.002862447,1.30411E-05,-0.000161729,,,,,-100,100,-100,100,,,From OpenStudio-HPXML +Minisplit-Heat-EIR-fT,DX Heating Coil,BiQuadratic,EIRRatio,Tiadb,Toadb,0.99999417,0.004684594,5.90129e-05,-0.002862447,1.30411e-05,-0.000161729,,,,,-100,100,-100,100,,,From OpenStudio-HPXML Minisplit-Heat-EIR-fFF,DX Heating Coil,Quadratic,EIRRatio,Tiadb,Toadb,1,0,0,,,,,,,,0,2,0,2,,,From OpenStudio-HPXML Minisplit-Heat-PLF-fPLR,DX Heating Coil,BiQuadratic,EIRRatio,Tiadb,Toadb,0.89,0.11,,,,,,,,,0,1,0.6,1,,,From OpenStudio-HPXML -Minisplit-Cool-Cap-fT,DX Cooling Coil,BiQuadratic,QRatio,Tiadb,Toadb,0.75319835,0.003618194,0,0.006574385,-6.87181E-05,0,,,,,0,100,0,100,,,From OpenStudio-HPXML +Minisplit-Cool-Cap-fT,DX Cooling Coil,BiQuadratic,QRatio,Tiadb,Toadb,0.75319835,0.003618194,0,0.006574385,-6.87181e-05,0,,,,,0,100,0,100,,,From OpenStudio-HPXML Minisplit-Cool-Cap-fFF,DX Cooling Coil,Quadratic,QRatio,Tiadb,Toadb,1,0,0,,,,,,,,0,2,0,2,,,From OpenStudio-HPXML -Minisplit-Cool-EIR-fT,DX Cooling Coil,BiQuadratic,EIRRatio,Tiadb,Toadb,-0.063769248,-0.001336059,1.41306E-05,0.019433076,-4.91396E-05,-4.90934E-05,,,,,0,100,0,100,,,From OpenStudio-HPXML +Minisplit-Cool-EIR-fT,DX Cooling Coil,BiQuadratic,EIRRatio,Tiadb,Toadb,-0.063769248,-0.001336059,1.41306e-05,0.019433076,-4.91396e-05,-4.90934e-05,,,,,0,100,0,100,,,From OpenStudio-HPXML Minisplit-Cool-EIR-fFF,DX Cooling Coil,Quadratic,EIRRatio,Tiadb,Toadb,1,0,0,,,,,,,,0,2,0,2,,,From OpenStudio-HPXML Minisplit-Cool-PLF-fPLR,DX Cooling Coil,BiQuadratic,EIRRatio,Tiadb,Toadb,0.89,0.11,,,,,,,,,0,1,0.6,1,,,From OpenStudio-HPXML EFG-Si_Spectral-fAirMass,PV-Module,Cubic,,AirMass,,0.93235892,0.05557786,-0.00723784,0.00016577,,,,,,,,,,,,,From .dat files included with MASControl2 @@ -214,13 +214,13 @@ Furnace-HIR-fPLR,Furnace,Quadratic,FIRRatio,PLR,,0.0186,1.09,-0.113,,,,,,,,0,1.0 Gas-Absor-Cap-fCHWT&ECT,Chiller/Heater,BiQuadratic,QRatio,CHWT,ECT,0.362073,0.0001386,0.001458,0.0733878,-0.00206064,0.00101,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 Gas-Absor-HCap-fCoolPLR,Chiller/Heater,Quadratic,QRatio,CoolPLR,,0.863599,-1.30495346,0.44135284,,,,,,,,,,,,,,From .dat files included with MASControl2 Gas-Absor-HIR-fCHWT&ECT,Chiller/Heater,BiQuadratic,,CHWT,ECT,0.96182051,-0.0507105,0.003155468,0.005732838,0.000349,-0.00118516,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Gas-Absor-HIR-fDesiccantT,Chiller/Heater,Cubic,,DesiccantT,,0.85427336,0.002997504,0.0000426,0,,,,,,,100,300,,,,,From .dat files included with MASControl2 +Gas-Absor-HIR-fDesiccantT,Chiller/Heater,Cubic,,DesiccantT,,0.85427336,0.002997504,4.26e-05,0,,,,,,,100,300,,,,,From .dat files included with MASControl2 Gas-Absor-Qreg-fDesiccantT,Chiller/Heater,Cubic,,DesiccantT,,0.5984,-0.00234,0,0,,,,,,,100,300,,,,,From .dat files included with MASControl2 GasTurbine-Cap-fPLR,GasTurbineGen,Linear,QRatio,PLR,,1.24,-0.0041,,,,,,,,,,,,,,,From .dat files included with MASControl2 GasTurbine-Exh-fPLR,GasTurbineGen,Quadratic,,PLR,,0.295626,0.4930194,0.2113548,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 GasTurbine-HIR-fPLR,GasTurbineGen,Quadratic,,PLR,,0.442979,0.3974,0.1569621,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 GHP-Bypass-Factor-fAirflow,GasHeat-Pump,Quadratic,QRatio,Airflow,,-0.254,1.22,0.036,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -GHP-Bypass-Factor-fEWB&EDB,GasHeat-Pump,BiQuadratic,QRatio,EWB,EDB,0.85028352,0.014256792,0.000184,-0.014791716,-0.00000548,0.000487,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +GHP-Bypass-Factor-fEWB&EDB,GasHeat-Pump,BiQuadratic,QRatio,EWB,EDB,0.85028352,0.014256792,0.000184,-0.014791716,-5.48e-06,0.000487,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 GHP-Bypass-Factor-fPLR,GasHeat-Pump,Linear,QRatio,PLR,,1,0,,,,,,,,,,,,,,,From .dat files included with MASControl2 GHP-Cool-Cap-fEWB&OAT,GasHeat-Pump,BiLinear,QRatio,EWB,OAT,1.1688,0.01926,-0.01539,,,,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 GHP-Cool-Cap-fRPM&OAT,GasHeat-Pump,BiQuadratic,QRatio,RPM,OAT,-372.736,-234.129654,-36.65800433,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 @@ -235,14 +235,14 @@ GHP-Heat-Cap-fEDB&OAT,GasHeat-Pump,BiQuadratic,QRatio,EDB,OAT,0.8291632,0,0,0.01 GHP-Heat-Cap-fRPM&OAT,GasHeat-Pump,BiQuadratic,QRatio,RPM,OAT,157.86,89.17133162,12.58409104,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 GHP-Heat-CondFan-fPLR&OAT,GasHeat-Pump,BiQuadratic,,PLR,OAT,1,0,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 GHP-Heat-CycleLoss-fPLR,GasHeat-Pump,Linear,QRatio,PLR,,0.82,0.18,,,,,,,,,,,,,,,From .dat files included with MASControl2 -GHP-Heat-HIR-fEDB&OAT,GasHeat-Pump,BiQuadratic,,EDB,OAT,1.14897728,0,0,-0.017395056,-0.000026,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 +GHP-Heat-HIR-fEDB&OAT,GasHeat-Pump,BiQuadratic,,EDB,OAT,1.14897728,0,0,-0.017395056,-2.6e-05,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 GHP-Heat-HIR-fRPM&OAT,GasHeat-Pump,BiQuadratic,,RPM,OAT,194.037,109.788263,15.50214113,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 GHP-Heat-Waste-Heat-fEDB&OAT,GasHeat-Pump,BiLinear,QRatio,EDB,OAT,1,0,0,,,,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 GHP-Heat-Waste-Heat-fRPM&OAT,GasHeat-Pump,BiQuadratic,QRatio,RPM,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 GHP-Sens-Cap-fEWB&OAT,GasHeat-Pump,BiQuadratic,QRatio,EWB,OAT,1.49637568,0.079056576,-0.004212,-0.030189312,0.000157,0.00062,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -Glass Door Defrost Curve,Refrigerated Case,Cubic,,,,0.3475,0.0296,0.0007,0.00003,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings -Glass Door Latent Curve,Refrigerated Case,Cubic,,,,0.3379,0.0309,0.0005,0.00004,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings -GoodCyclingAC-EIR-fPLR,CyclingAC,Cubic,EIRRatio,PLR,,0.00000273,1.05259,-0.0552087,0.00262236,,,,,,,,,,,,,From .dat files included with MASControl2 +Glass Door Defrost Curve,Refrigerated Case,Cubic,,,,0.3475,0.0296,0.0007,3e-05,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings +Glass Door Latent Curve,Refrigerated Case,Cubic,,,,0.3379,0.0309,0.0005,4e-05,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings +GoodCyclingAC-EIR-fPLR,CyclingAC,Cubic,EIRRatio,PLR,,2.73e-06,1.05259,-0.0552087,0.00262236,,,,,,,,,,,,,From .dat files included with MASControl2 GSHP/WLHP_BF_fAirflow-Old,GSHP/WLHPCurves,Cubic,QRatio,Airflow,,-0.828,14.3,-21.9,9.4,,,,,,,,,,,,,From .dat files included with MASControl2 GSHP/WLHP_BF_fEwbEwt,GSHP/WLHPCurves,BiLinear,QRatio,EWB,EWT,-0.2016,0.0297,0.02646,,,,,,,,,,,,0.347365,1.67341,From .dat files included with MASControl2 GSHP/WLHP_BF_fEwbEwt-Old,GSHP/WLHPCurves,BiQuadratic,QRatio,EWB,EWT,-5.522656,0.735768,-0.0185004,0.1418832,0.000943,-0.010206,,,,,,,,,,,From .dat files included with MASControl2 @@ -261,28 +261,28 @@ Herm-Rec-Cap-fCHWT&ECT,HermReciprocatg,BiQuadratic,QRatio,CHWT,ECT,0.507883,0.14 Herm-Rec-EIR-fCHWT&ECT,HermReciprocatg,BiQuadratic,EIRRatio,CHWT,ECT,1.030757,-0.103536,0.00710208,0.0093186,0.000318,-0.00104,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 Herm-Rec-EIR-fPLR,HermReciprocatg,Quadratic,EIRRatio,PLR,,0.088065,1.137742,-0.225806,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 Hospital Kitchen_Flr_5_Case:1_WALKINFREEZERSingleShelfHorizontal_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.0236,0.0006,0,0,,,,,,,-35,20,,,,,From Prototype Buildings -Hospital Kitchen_Flr_5_Case:2_SELFCONTAINEDDISPLAYCASEMultiShelfVertical_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,6.02558E-05,1.23732E-06,,,,,,,-35,20,,,,,From Prototype Buildings +Hospital Kitchen_Flr_5_Case:2_SELFCONTAINEDDISPLAYCASEMultiShelfVertical_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,6.02558e-05,1.23732e-06,,,,,,,-35,20,,,,,From Prototype Buildings HotelLarge Kitchen_Flr_6_Case:1_WALKINFREEZERSingleShelfHorizontal_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.0236,0.0006,0,0,,,,,,,-35,20,,,,,From Prototype Buildings -HotelLarge Kitchen_Flr_6_Case:2_SELFCONTAINEDDISPLAYCASEMultiShelfVertical_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,6.02558E-05,1.23732E-06,,,,,,,-35,20,,,,,From Prototype Buildings +HotelLarge Kitchen_Flr_6_Case:2_SELFCONTAINEDDISPLAYCASEMultiShelfVertical_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,6.02558e-05,1.23732e-06,,,,,,,-35,20,,,,,From Prototype Buildings HP-Bypass-Factor-fAirflow,Water-LoopHP,Cubic,QRatio,Airflow,,-0.828,14.3,-21.9,9.4,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 HP-Bypass-Factor-fEWB&EWT,Water-LoopHP,BiQuadratic,QRatio,EWB,EWT,-5.522656,0.735768,-0.0185004,0.1418832,0.000943,-0.010206,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -HP-Cool-Cap-fEWB&EWT,Water-LoopHP,BiQuadratic,QRatio,EWB,EWT,0.38053696,0.041974272,-0.0000309,-0.006642864,0.0000228,-0.0000881,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -HP-Cool-EIR-fEWB&EWT,Water-LoopHP,BiQuadratic,EIRRatio,EWB,EWT,1.3257696,-0.0504504,0.000988,0.02036448,0.0000791,-0.000531,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +HP-Cool-Cap-fEWB&EWT,Water-LoopHP,BiQuadratic,QRatio,EWB,EWT,0.38053696,0.041974272,-3.09e-05,-0.006642864,2.28e-05,-8.81e-05,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +HP-Cool-EIR-fEWB&EWT,Water-LoopHP,BiQuadratic,EIRRatio,EWB,EWT,1.3257696,-0.0504504,0.000988,0.02036448,7.91e-05,-0.000531,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 HP-Cool-EIR-fPLR,Water-LoopHP,Linear,EIRRatio,PLR,,0.125,0.875,,,,,,,,,,,,,,,From .dat files included with MASControl2 HP-Heat-Cap-fEDB&EWT,Water-LoopHP,BiLinear,QRatio,EDB,EWT,0.72324,-0.012204,0.02538,,,,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 HP-Heat-EIR-fEDB&EWT,Water-LoopHP,BiLinear,EIRRatio,EDB,EWT,1.2124,0.01089,-0.02088,,,,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 HP-Heat-EIR-fPLR,Water-LoopHP,Cubic,EIRRatio,PLR,,0.0857,0.939,-0.183,0.15897022,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 HP-Sens-Cap-fAirflow,Water-LoopHP,Cubic,QRatio,Airflow,,-0.13,2.16,-1.6,0.573,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -HP-Sens-Cap-fEWB&EWT,Water-LoopHP,BiQuadratic,QRatio,EWB,EWT,1.68318464,0.012410496,-0.00215784,-0.009251064,0.0000632,0.000174,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +HP-Sens-Cap-fEWB&EWT,Water-LoopHP,BiQuadratic,QRatio,EWB,EWT,1.68318464,0.012410496,-0.00215784,-0.009251064,6.32e-05,0.000174,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 HPACCoolCapFFF,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,, -HPACCoolCapFT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.766956,0.0107756,-4.14703E-05,0.00134961,-0.000261144,0.000457488,,,,,12.77778,23.88889,21.11111,46.11111,,, +HPACCoolCapFT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.766956,0.0107756,-4.14703e-05,0.00134961,-0.000261144,0.000457488,,,,,12.77778,23.88889,21.11111,46.11111,,, HPACCOOLEIRFFF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.156,-0.1816,0.0256,,,,,,,,0.5,1.5,,,,, HPACCOOLEIRFT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.297145,0.0430933,-0.000748766,0.00597727,0.000482112,-0.000956448,,,,,12.77778,23.88889,21.11111,46.11111,,, HPACCOOLPLFFPLR,DX Cooling Coil,Quadratic,EIRRatio,QRatio,,0.85,0.15,0,,,,,,,,0,1,,,,, HPACHeatCapFFF,DX Heating Coil,Cubic,QRatio,FlowRatio,,0.84,0.16,0,0,,,,,,,0.5,1.5,,,,,From Prototype Buildings -HPACHeatCapFT,DX Heating Coil,Cubic,QRatio,Toadb,,0.758746,0.027626,0.000148716,3.4992E-06,,,,,,,-20,20,,,,,From Prototype Buildings +HPACHeatCapFT,DX Heating Coil,Cubic,QRatio,Toadb,,0.758746,0.027626,0.000148716,3.4992e-06,,,,,,,-20,20,,,,,From Prototype Buildings HPACHeatEIRFFF,DX Heating Coil,Quadratic,EIRRatio,FlowRatio,,1.3824,-0.4336,0.0512,,,,,,,,0,1,,,,,From Prototype Buildings -HPACHeatEIRFT,DX Heating Coil,Cubic,EIRRatio,Toadb,,1.19248,-0.0300438,0.00103745,-0.000023328,,,,,,,-20,20,,,,,From Prototype Buildings +HPACHeatEIRFT,DX Heating Coil,Cubic,EIRRatio,Toadb,,1.19248,-0.0300438,0.00103745,-2.3328e-05,,,,,,,-20,20,,,,,From Prototype Buildings Htrec-Chlr-Cap-fCHWT&ECT,ElecHeatRecover,BiQuadratic,QRatio,CHWT,ECT,0.257896,0.0389016,-0.000217,0.0468684,-0.000943,-0.000343,,,,,4.44444,18.33333,12.77778,51.66667,,,From .dat files included with MASControl2 Htrec-Chlr-EIR-fCHWT&ECT,ElecHeatRecover,BiQuadratic,EIRRatio,CHWT,ECT,0.933884,-0.058212,0.00450036,0.00243,0.000486,-0.001215,,,,,4.44444,18.33333,12.77778,51.66667,,,From .dat files included with MASControl2 Htrec-Chlr-EIR-fPLR,ElecHeatRecover,Quadratic,EIRRatio,PLR,,0.349032,0.263871,0.387097,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 @@ -297,7 +297,7 @@ Large-CHW-Coil-Bypass-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,0.435936,0.23 Large-CHW-Coil-Cap-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,0.09793216,-0.13886496,0.0124416,0.088907328,0.001938946,-0.009305604,,,,,15.55556,29.44444,12.77778,29.44444,,,From .dat files included with MASControl2 Large-CHW-Sens-Cap-fAirflow,CHWCoils,Quadratic,QRatio,Airflow,,0.202,0.855,-0.057,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 Large-CHW-Sens-Cap-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,0.12076864,-0.124558848,0.0063828,0.11146032,0.001847902,-0.006508285,,,,,15.55556,13.33333,12.77778,29.44444,,,From .dat files included with MASControl2 -Lp2Lp_Cap_fCHW&HWR,Loop2Loop,BiQuadratic,QRatio,CHWT,HWR,0.95122179,0.035393436,0.00027,-0.002654118,-0.0000869,-0.000274,,,,,,,,,,,From .dat files included with MASControl2 +Lp2Lp_Cap_fCHW&HWR,Loop2Loop,BiQuadratic,QRatio,CHWT,HWR,0.95122179,0.035393436,0.00027,-0.002654118,-8.69e-05,-0.000274,,,,,,,,,,,From .dat files included with MASControl2 Lp2Lp_EIR_fCHW&HWR,Loop2Loop,BiQuadratic,EIRRatio,CHWT,HWR,0.59918703,-0.00950724,0.000335,0.00863883,0.000312,-0.000386,,,,,,,,,,,From .dat files included with MASControl2 Lp2Lp-EIR-fPLR-1Comp/Ckt,Loop2Loop,Quadratic,EIRRatio,PLR,,0.03481113,0.95945376,0.00573495,,,,,,,,,,,,,,From .dat files included with MASControl2 Lp2Lp-EIR-fPLR-2Comp/Ckt,Loop2Loop,Quadratic,EIRRatio,PLR,,0.02297712,0.90150452,0.07551826,,,,,,,,,,,,,,From .dat files included with MASControl2 @@ -309,13 +309,13 @@ MNECB-CAP-FAPP&WB,CAP-FAPP&WB,BiQuadratic,QRatio,App,WB,-0.05425558,-0.063981648 MNECB-CAP-FRNG&WB,CAP-FRNG&WB,BiQuadratic,QRatio,Rng,WB,188.8588489,0.300231774,-0.045692003,35.40844622,0.601350934,0.78576062,,,,,,,,,,,From .dat files included with MASControl2 MNECB-Centrif-CAP-FT,Centrif-CAP-FT,BiQuadratic,QRatio,T,T,0.70790824,-0.002006568,-0.00259605,0.030058776,-0.001056434,0.002045704,,,,,,,,,,,From .dat files included with MASControl2 MNECB-Centrif-EIR-FPLR,Centrif-EIR-FPLR,Quadratic,EIRRatio,PLR,,0.17149273,0.58820208,0.23737257,,,,,,,,,,,,,,From .dat files included with MASControl2 -MNECB-Centrif-EIR-FT,Centrif-EIR-FT,BiQuadratic,EIRRatio,T,T,0.5605438,-0.01377927,0.0000657,0.013219362,0.000268596,-0.000501131,,,,,,,,,,,From .dat files included with MASControl2 +MNECB-Centrif-EIR-FT,Centrif-EIR-FT,BiQuadratic,EIRRatio,T,T,0.5605438,-0.01377927,6.57e-05,0.013219362,0.000268596,-0.000501131,,,,,,,,,,,From .dat files included with MASControl2 MNECB-DW-HIR-fPLR,DHW-HIR,Quadratic,,PLR,,0.021826,0.97763,0.000543,,,,,,,,,,,,,,From .dat files included with MASControl2 MNECB-HW-HIR-fPLR,HW-HIR,Quadratic,,PLR,,0.082597,0.996764,-0.079361,,,,,,,,,,,,,,From .dat files included with MASControl2 -MNECB-Recip-CAP-FT,Recip-CAP-FT,BiQuadratic,QRatio,T,T,1.0303123,0.033469794,0.00023639,-0.007295868,-0.0000232,-0.000148943,,,,,,,,,,,From .dat files included with MASControl2 +MNECB-Recip-CAP-FT,Recip-CAP-FT,BiQuadratic,QRatio,T,T,1.0303123,0.033469794,0.00023639,-0.007295868,-2.32e-05,-0.000148943,,,,,,,,,,,From .dat files included with MASControl2 MNECB-Recip-EIR-FPLR,Recip-EIR-FPLR,Quadratic,EIRRatio,PLR,,0.08144133,0.41927141,0.49939604,,,,,,,,,,,,,,From .dat files included with MASControl2 MNECB-Recip-EIR-FT,Recip-EIR-FT,BiQuadratic,EIRRatio,T,T,0.49969897,-0.013084056,0.000266425,0.016592526,0.000185393,-0.000375646,,,,,,,,,,,From .dat files included with MASControl2 -Multi Shelf Vertical Latent Energy Multiplier,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,-6.02558E-05,1.23732E-06,,,,,,,-35,20,,,,,From Reference Buildings +Multi Shelf Vertical Latent Energy Multiplier,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,-6.02558e-05,1.23732e-06,,,,,,,-35,20,,,,,From Reference Buildings Multi Zone VAV with Airfoil or Backward Incline riding the curve,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.1631,1.5901,-0.8817,0.1281,,,,,,,0,1,,,0.7,,From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method Multi Zone VAV with Airfoil or Backward Incline with inlet vanes,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.9977,-0.659,0.9547,-0.2936,,,,,,,0,1,,,0.5,,From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method Multi Zone VAV with Forward Curved fans riding the curve,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.1224,0.612,0.5983,-0.3334,,,,,,,0,1,,,0.3,,From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method @@ -332,7 +332,7 @@ Old_Low_Temp_Comp_Cap_Curve,,BiCubic,,,,170751.834,6102.9037,78.2619862,-2959.43 Old_Low_Temp_Comp_Pwr_Curve,,BiCubic,,,,29669.2711,1027.63205,18.1066262,-442.199714,11.1335288,-20.3804519,0.139980653,-0.058866918,-0.218451538,0.203858467,-40,-17.8,4.4,54.4,,, Old_Med_Temp_Comp_Cap_Curve,,BiCubic,,,,151166.436,5266.34789,60.6727151,-1851.55938,5.73132755,-46.9277173,0.136401203,-0.035697884,-0.403053994,-0.039290478,-23.3,7.2,10,60,,, Old_Med_Temp_Comp_Pwr_Curve,,BiCubic,,,,7438.92229,-269.597565,-9.85610446,553.57326,-3.38588961,14.8657878,-0.100796292,0.009822793,0.097362356,-0.039675217,-23.3,7.2,10,60,,, -Open Latent Curve,Refrigerated Case,Cubic,,,,-0.0187,0.0458,0.0011,0.00005,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings +Open Latent Curve,Refrigerated Case,Cubic,,,,-0.0187,0.0458,0.0011,5e-05,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings Open-Cent-Cap-fCHWT&ECT,OpenCentrifugal,BiQuadratic,QRatio,CHWT,ECT,0.257896,0.0389016,-0.000217,0.0468684,-0.000943,-0.000343,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 Open-Cent-EIR-fCHWT&ECT,OpenCentrifugal,BiQuadratic,EIRRatio,CHWT,ECT,0.933884,-0.058212,0.00450036,0.00243,0.000486,-0.001215,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 Open-Cent-EIR-fPLR,OpenCentrifugal,Quadratic,EIRRatio,PLR,,0.222903,0.313387,0.46371,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 @@ -344,32 +344,32 @@ OpenTwr-FluidCap-fRng&WB,OpenTower,BiQuadratic,QRatio,Rng,WB,0.11661702,0.202450 PoorCyclingAC-EIR-fPLR,CyclingAC,Cubic,EIRRatio,PLR,,0.000362523,1.32573,-0.407603,0.0818194,,,,,,,,,,,,,From .dat files included with MASControl2 PSZ-AC DX Coil EIR-FT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.342414409,0.034885008,-0.0006237,0.004977216,0.000437951,-0.000728028,,,,,12.77778,23.88889,23.88889,46.11111,,,"From PNNL Prototype Buildings HotelSmall, Warehouse" PSZ-AC DX Unitary Package EIRFT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.297145,0.0430933,-0.000748766,0.00597727,0.000482112,-0.000956448,,,,,12.77778,23.88889,21.11111,46.11111,,,"From PNNL Prototype Buildings RetailStandAlone, RetailStripMall,SchoolPrimary" -PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.42415,0.04426,-0.00042,0.00333,-0.00008,-0.00021,,,,,17,22,29,46,,,"From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" +PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.42415,0.04426,-0.00042,0.00333,-8e-05,-0.00021,,,,,17,22,29,46,,,"From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR,DX Cooling Coil,Quadratic,EIRRatio,QRatio,,0.771,0.229,0,,,,,,,,0,1,,,,,"From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" PSZ-AC_CoolCStandard10Ton_EIRFT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,1.23649,-0.02431,0.00057,-0.01434,0.00063,-0.00038,,,,,17,22,29,46,,,"From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" -PSZ-AC_Unitary_PackagecoolCapFT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.766956,0.0107756,-4.14703E-05,0.00134961,-0.000261144,0.000457488,,,,,12.77778,23.88889,21.11111,46.11111,,,"From PNNL Prototype Buildings RetailStandalone, RetailStripMall, SchoolPrimary" +PSZ-AC_Unitary_PackagecoolCapFT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.766956,0.0107756,-4.14703e-05,0.00134961,-0.000261144,0.000457488,,,,,12.77778,23.88889,21.11111,46.11111,,,"From PNNL Prototype Buildings RetailStandalone, RetailStripMall, SchoolPrimary" PSZ-AC_Unitary_PackagecoolEIRFFF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.156,-0.1816,0.0256,,,,,,,,0.5,1.5,,,,, PSZ-AC_Unitary_PackagecoolFFF,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,, PSZ-AC_Unitary_PackagecoolPLR,DX Cooling Coil,Quadratic,EIRRatio,QRatio,,0.75,0.25,0,,,,,,,,0,1,,,,,"From PNNL Prototype Buildings RetailStandAlone, RetailStripMall, SchoolPrimary" PSZ-AC:1_Unitary_PackagecoolEIRFFF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.156,-0.1816,0.0256,,,,,,,,0.5,1.5,,,,,"From PNNL Prototype Buildings RetailStandAlone, RetailStripMall, SchoolPrimary" -PSZ-Fine Storage DX Coil Cap-FT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.942587793,0.009543347,0.00068377,-0.011042676,0.000005249,-0.00000972,,,,,12.77778,23.88889,23.88889,46.11111,,,"From PNNL Prototype Buildings HotelSmall, Warehouse" +PSZ-Fine Storage DX Coil Cap-FT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.942587793,0.009543347,0.00068377,-0.011042676,5.249e-06,-9.72e-06,,,,,12.77778,23.88889,23.88889,46.11111,,,"From PNNL Prototype Buildings HotelSmall, Warehouse" PSZ-Fine Storage Heating Coil PLF-FPLR,DX Heating Coil,Cubic,EIRRatio,QRatio,,0.8,0.2,0,0,,,,,,,0,1,,,,,From Prototype Buildings PSZ-Office Heating Coil PLF-FPLR,DX Heating Coil,Cubic,EIRRatio,QRatio,,0.8,0.2,0,0,,,,,,,0,1,,,,,From Prototype Buildings PSZ135to240_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 PSZ135to240_BF_fT,BF_fT,BiQuadratic,,T,T,43.269632,-4.898304,0.148392,0.0947376,0.00213192,-0.0134136,,,,,,,,,0,4.04,From .dat files included with MASControl2 PSZ135to240_CEIR_fPLR,CEIR_fPLR,Cubic,EIRRatio,PLR,,0.0184,1.15,-0.208,0.0423,,,,,,,,,,,,,From .dat files included with MASControl2 -PSZ135to240_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.62774528,-0.060192,0.00260172,-0.005653656,0.0000266,-0.00040824,,,,,,,,,,,From .dat files included with MASControl2 +PSZ135to240_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.62774528,-0.060192,0.00260172,-0.005653656,2.66e-05,-0.00040824,,,,,,,,,,,From .dat files included with MASControl2 PSZ135to240_CLoss_fPLR,CLoss_fPLR,Cubic,,PLR,,0.852,0.203,-0.0423,0.00938,,,,,,,,,,,0.8024,1.0728,From .dat files included with MASControl2 -PSZ135to240_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,0.4018688,0.1920384,-0.0077436,-0.01956816,-0.0000415,0.00077436,,,,,,,,,,,From .dat files included with MASControl2 +PSZ135to240_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,0.4018688,0.1920384,-0.0077436,-0.01956816,-4.15e-05,0.00077436,,,,,,,,,,,From .dat files included with MASControl2 PSZ135to240_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,-0.0449056,0.07059456,-0.00216432,0.00440856,0.00041148,-0.000245916,,,,,,,,,,,From .dat files included with MASControl2 PSZ135to240_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 PSZ135to240_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 PSZ240to760_BF_fFlow,BF_fFlow,Linear,QRatio,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 PSZ240to760_BF_fT,BF_fT,BiQuadratic,,T,T,15.8724544,-1.6604928,0.041148,0.03013992,0.000278964,0.00047628,,,,,,,,,0,3.252,From .dat files included with MASControl2 PSZ240to760_CEIR_fPLR,CEIR_fPLR,Cubic,EIRRatio,PLR,,2.63,-9.5,14.3,-6.4,,,,,,,,,,,,,From .dat files included with MASControl2 -PSZ240to760_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.27910208,-0.0291096,0.00167184,-0.002266416,-0.000031,-0.00033372,,,,,,,,,,,From .dat files included with MASControl2 +PSZ240to760_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.27910208,-0.0291096,0.00167184,-0.002266416,-3.1e-05,-0.00033372,,,,,,,,,,,From .dat files included with MASControl2 PSZ240to760_CLoss_fPLR,CLoss_fPLR,Cubic,,PLR,,0.964,0.289,0.183,-0.131,,,,,,,,,,,0.96,1.3,From .dat files included with MASControl2 -PSZ240to760_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.64083712,-0.06152112,-0.0004698,-0.010834704,-0.0000289,0.000222912,,,,,,,,,,,From .dat files included with MASControl2 +PSZ240to760_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.64083712,-0.06152112,-0.0004698,-0.010834704,-2.89e-05,0.000222912,,,,,,,,,,,From .dat files included with MASControl2 PSZ240to760_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.336608,0.0487944,-0.00116316,-0.005994,0.00067716,-0.00069012,,,,,,,,,,,From .dat files included with MASControl2 PSZ240to760_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 PSZ240to760_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 @@ -385,7 +385,7 @@ PSZ65to135_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat fi PTAC_EIR_fPLR,PkgdTerminalACS,Cubic,EIRRatio,PLR,,0.125,0.875,0,0,,,,,,,,,,,,,From .dat files included with MASControl2 PTAC-Bypass-Factor-fAirflow,PkgdTerminalAC,Quadratic,QRatio,Airflow,,-2.28,5.21,-1.93,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 PTAC-Bypass-Factor-fEWB&EDB,PkgdTerminalAC,BiQuadratic,QRatio,EWB,EDB,-0.219664,0.0994608,0.00102,-0.020394,0.00036,-0.00120528,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -PTAC-Cool-Cap-fEWB&OAT,PkgdTerminalAC,BiQuadratic,QRatio,EWB,OAT,0.93865088,0.0095364,0.000684,-0.011038176,0.00000525,-0.00000972,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +PTAC-Cool-Cap-fEWB&OAT,PkgdTerminalAC,BiQuadratic,QRatio,EWB,OAT,0.93865088,0.0095364,0.000684,-0.011038176,5.25e-06,-9.72e-06,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 PTAC-EIR-fEWB&OAT,PkgdTerminalAC,BiQuadratic,EIRRatio,EWB,OAT,0.34208928,0.03484368,-0.000625,0.004968864,0.000438,-0.000728,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 PTAC-EIR-fPLR,PkgdTerminalAC,Linear,EIRRatio,PLR,,0.125,0.875,,,,,,,,,,,,,,,From .dat files included with MASControl2 PTAC-Sens-Cap-fAirflow,PkgdTerminalAC,Linear,QRatio,Airflow,,0.6,0.4,,,,,,,,,,,,,,,From .dat files included with MASControl2 @@ -396,21 +396,21 @@ Pump-Power-fFlow,Pumps,Quadratic,,Flow,,0.3697739,1780.65378,-943000,,,,,,,,0,1. PVV240to760_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 PVV240to760_BF_fT,BF_fT,BiQuadratic,,T,T,8.747712,-1.2544704,0.034992,0.219888,-0.00221292,-0.00284796,,,,,,,,,0,3.2,From .dat files included with MASControl2 PVV240to760_CEIR_fPLR,CEIR_fPLR,Cubic,EIRRatio,PLR,,0.124,0.376,1.29,-0.794,,,,,,,,,,,,,From .dat files included with MASControl2 -PVV240to760_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,0.9521152,-0.01097712,0.0012312,-0.00072792,-0.0000454,-0.000173988,,,,,,,,,,,From .dat files included with MASControl2 +PVV240to760_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,0.9521152,-0.01097712,0.0012312,-0.00072792,-4.54e-05,-0.000173988,,,,,,,,,,,From .dat files included with MASControl2 PVV240to760_CLoss_fPLR,CLoss_fPLR,Cubic,,PLR,,0,1,0,0,,,,,,,,,,,0.1,1,From .dat files included with MASControl2 -PVV240to760_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.91654848,0.0047736,-0.00233604,-0.013756896,-0.0000323,0.00057672,,,,,,,,,,,From .dat files included with MASControl2 +PVV240to760_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.91654848,0.0047736,-0.00233604,-0.013756896,-3.23e-05,0.00057672,,,,,,,,,,,From .dat files included with MASControl2 PVV240to760_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.380192,0.0241488,-0.00047952,0.0111168,0.00052488,-0.00102384,,,,,,,,,,,From .dat files included with MASControl2 PVV240to760_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 PVV240to760_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 PVVT-Bypass-Factor-fAirflow,PkgdVVVT,Quadratic,QRatio,Airflow,,-0.254,1.22,0.036,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -PVVT-Bypass-Factor-fEWB&EDB,PkgdVVVT,BiQuadratic,QRatio,EWB,EDB,0.85028352,0.014256792,0.000184,-0.014791716,-0.00000548,0.000487,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -PVVT-Cool-Cap-fEWB&OAT,PkgdVVVT,BiQuadratic,QRatio,EWB,OAT,0.86783424,0.014239008,0.000554,-0.007558056,0.000033,-0.000192,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +PVVT-Bypass-Factor-fEWB&EDB,PkgdVVVT,BiQuadratic,QRatio,EWB,EDB,0.85028352,0.014256792,0.000184,-0.014791716,-5.48e-06,0.000487,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +PVVT-Cool-Cap-fEWB&OAT,PkgdVVVT,BiQuadratic,QRatio,EWB,OAT,0.86783424,0.014239008,0.000554,-0.007558056,3.3e-05,-0.000192,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 PVVT-Cool-EIR-fEWB&OAT,PkgdVVVT,BiQuadratic,EIRRatio,EWB,OAT,0.1210048,0.0285336,-0.000411,0.02134944,0.000161,-0.00068,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 PVVT-Cool-EIR-fPLR,PkgdVVVT,Cubic,EIRRatio,PLR,,0.201,-0.0312,1.9504979,-1.1205104,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -PVVT-Heat-Cap-fEDB&OAT,PkgdVVVT,BiQuadratic,QRatio,EDB,OAT,0.74200928,0,0,0.030668544,0.0000323,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 +PVVT-Heat-Cap-fEDB&OAT,PkgdVVVT,BiQuadratic,QRatio,EDB,OAT,0.74200928,0,0,0.030668544,3.23e-05,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 PVVT-Heat-EIR-fEDB&OAT,PkgdVVVT,BiQuadratic,EIRRatio,EDB,OAT,1.255664,0,0,-0.0399528,0.00108864,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 PVVT-Heat-EIR-fPLR,PkgdVVVT,Cubic,EIRRatio,PLR,,0.0857,0.939,-0.183,0.159,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -PVVT-Sens-Cap-fEWB&OAT,PkgdVVVT,BiQuadratic,QRatio,EWB,OAT,2.93229888,-0.09445968,0.0002,-0.007173756,0.0000103,0.000109,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +PVVT-Sens-Cap-fEWB&OAT,PkgdVVVT,BiQuadratic,QRatio,EWB,OAT,2.93229888,-0.09445968,0.0002,-0.007173756,1.03e-05,0.000109,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 Rcmp-kW-f-Tc-T1-Hi-Eff,Refrigeration,Quadratic,,Tc,,0.635620298,0.003533521,0.000161,,,,,,,,,,,,0.7533,1.2802,From .dat files included with MASControl2 Rcmp-kW-f-Tc-T1-Low-Eff,Refrigeration,Quadratic,,Tc,,1.113461,-0.0308988,0.000739,,,,,,,,,,,,0.950084,1.606833,From .dat files included with MASControl2 Rcmp-kW-f-Tc-T2-Hi-Eff,Refrigeration,Quadratic,,Tc,,0.580834119,0.00494838,0.000161,,,,,,,,,,,,0.7262,1.3046,From .dat files included with MASControl2 @@ -425,17 +425,17 @@ Rcmp-kW2-f-Tc-T3-Hi-Eff,Refrigeration,Quadratic,,Tc,,0.829593266,-0.014865914,0. Rcmp-kW2-f-Tc-T3-Low-Eff,Refrigeration,Quadratic,,Tc,,0.656539,-0.0039924,0.00035,,,,,,,,,,,,0.941987,1.418136,From .dat files included with MASControl2 Rcond-Fan-Pwr-fPLR-ACpress,Refrigeration,Linear,,PLR,,0,1,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 Rcond-Fan-Pwr-fPLR-Damper,Refrigeration,Linear,,PLR,,0.3,0.7,,,,,,,,,,,,,0.3,1,From .dat files included with MASControl2 -RecipAir-Cap-fCHWT&DBT,HermReciprocatg,BiQuadratic,QRatio,CHWT,DBT,1.10674018,0.040197888,0.000286,-0.009552852,0.00000522,-0.000255,,,,,,,,,,,From .dat files included with MASControl2 +RecipAir-Cap-fCHWT&DBT,HermReciprocatg,BiQuadratic,QRatio,CHWT,DBT,1.10674018,0.040197888,0.000286,-0.009552852,5.22e-06,-0.000255,,,,,,,,,,,From .dat files included with MASControl2 RecipAir-EIR-fCHWT&DBT,HermReciprocatg,BiQuadratic,EIRRatio,CHWT,DBT,0.53866251,-0.008142246,0.000125,0.011090538,0.000164,-0.000342,,,,,,,,,,,From .dat files included with MASControl2 -RecipAir-EIR-fPLR-1Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.03892594,1.07531738,-0.10724027,-0.001050714,0.00000943,0.000536346,,,,,,,,,,,From .dat files included with MASControl2 -RecipAir-EIR-fPLR-2Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.04812248,0.69573414,0.2349389,0.000819378,-0.00000386,0.0000379,,,,,,,,,,,From .dat files included with MASControl2 -RecipAir-EIR-fPLR-3Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.03296722,0.57721251,0.33923307,0.002786436,-0.0000311,-0.000119,,,,,,,,,,,From .dat files included with MASControl2 -RecipAir-EIR-fPLR-4Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.00434876,0.61917436,0.32643354,0.003223368,-0.0000333,-0.000514206,,,,,,,,,,,From .dat files included with MASControl2 -RecipH2O-Cap-fCHWT&ECT,HermReciprocatg,BiQuadratic,QRatio,CHWT,ECT,1.0689798,0.036781398,0.000334,-0.010426122,0.0000217,-0.000208,,,,,,,,,,,From .dat files included with MASControl2 +RecipAir-EIR-fPLR-1Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.03892594,1.07531738,-0.10724027,-0.001050714,9.43e-06,0.000536346,,,,,,,,,,,From .dat files included with MASControl2 +RecipAir-EIR-fPLR-2Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.04812248,0.69573414,0.2349389,0.000819378,-3.86e-06,3.79e-05,,,,,,,,,,,From .dat files included with MASControl2 +RecipAir-EIR-fPLR-3Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.03296722,0.57721251,0.33923307,0.002786436,-3.11e-05,-0.000119,,,,,,,,,,,From .dat files included with MASControl2 +RecipAir-EIR-fPLR-4Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.00434876,0.61917436,0.32643354,0.003223368,-3.33e-05,-0.000514206,,,,,,,,,,,From .dat files included with MASControl2 +RecipH2O-Cap-fCHWT&ECT,HermReciprocatg,BiQuadratic,QRatio,CHWT,ECT,1.0689798,0.036781398,0.000334,-0.010426122,2.17e-05,-0.000208,,,,,,,,,,,From .dat files included with MASControl2 RecipH2O-EIR-fCHWT&ECT,HermReciprocatg,BiQuadratic,EIRRatio,CHWT,ECT,0.51329254,-0.015039378,0.000362,0.015398694,0.000228,-0.000409,,,,,,,,,,,From .dat files included with MASControl2 -RecipH2O-EIR-fPLR&dT-1Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,-0.0142974,0.95360994,0.01805304,0.002822994,-0.0000199,-0.000497988,,,,,,,,,,,From .dat files included with MASControl2 -RecipH2O-EIR-fPLR&dT-2Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.02391765,0.88946915,0.07793053,-0.000474426,0.0000233,0.000324,,,,,,,,,,,From .dat files included with MASControl2 -RecipRemote-Cap-fCHWT&SCT,HermReciprocatg,BiQuadratic,QRatio,CHWT,SCT,1.27977199,0.051393222,0.000332,-0.009522792,-0.0000197,-0.000269,,,,,,,,,,,From .dat files included with MASControl2 +RecipH2O-EIR-fPLR&dT-1Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,-0.0142974,0.95360994,0.01805304,0.002822994,-1.99e-05,-0.000497988,,,,,,,,,,,From .dat files included with MASControl2 +RecipH2O-EIR-fPLR&dT-2Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.02391765,0.88946915,0.07793053,-0.000474426,2.33e-05,0.000324,,,,,,,,,,,From .dat files included with MASControl2 +RecipRemote-Cap-fCHWT&SCT,HermReciprocatg,BiQuadratic,QRatio,CHWT,SCT,1.27977199,0.051393222,0.000332,-0.009522792,-1.97e-05,-0.000269,,,,,,,,,,,From .dat files included with MASControl2 RecipRemote-EIR-fCHWT&SCT,HermReciprocatg,BiQuadratic,EIRRatio,CHWT,SCT,0.25314951,-0.015358788,0.000506,0.009717714,0.000171,-0.000382,,,,,,,,,,,From .dat files included with MASControl2 RecipRemote-EIR-fPLR-1Comp/Ckt,HermReciprocatg,Quadratic,EIRRatio,PLR,,0.03521065,0.93266129,0.03212802,,,,,,,,,,,,,,From .dat files included with MASControl2 RecipRemote-EIR-fPLR-2Comp/Ckt,HermReciprocatg,Quadratic,EIRRatio,PLR,,0.02511026,0.8934145,0.08147529,,,,,,,,,,,,,,From .dat files included with MASControl2 @@ -450,10 +450,10 @@ Refg-kW2-fECT-T3,Refrigeration,Quadratic,,ECT,,0.671617,-0.0074358,0.000424,,,,, Residential Fix Vol-Fan EIR,FanEIR-FPLR,Linear,EIRRatio,PLR,,1,0,,,,,,,,,,,,,,,From .dat files included with MASControl2 Residential Var Vol-Fan EIR,FanEIR-FPLR,Cubic,EIRRatio,PLR,,0.000281,-0.0579,0.586,0.471,,,,,,,,,,,,,From .dat files included with MASControl2 RestaurantFastFood Kitchen_Case:1_WALKINFREEZERSingleShelfHorizontal_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.0236,0.0006,0,0,,,,,,,-35,20,,,,,From Prototype Buildings -RestaurantFastFood Kitchen_Case:2_SELFCONTAINEDDISPLAYCASEMultiShelfVertical_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,6.02558E-05,1.23732E-06,,,,,,,-35,20,,,,,From Prototype Buildings +RestaurantFastFood Kitchen_Case:2_SELFCONTAINEDDISPLAYCASEMultiShelfVertical_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,6.02558e-05,1.23732e-06,,,,,,,-35,20,,,,,From Prototype Buildings RESVVT-Bypass-Factor-fAirflow,ResidentialVVVT,Quadratic,QRatio,Airflow,,-0.254,1.22,0.036,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -RESVVT-Bypass-Factor-fEWB&EDB,ResidentialVVVT,BiQuadratic,QRatio,EWB,EDB,0.85086272,0.014256792,0.000184,-0.014759136,-0.00000548,0.000487,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -RESVVT-Cool-Cap-fEWB&OAT,ResidentialVVVT,BiQuadratic,QRatio,EWB,OAT,0.47523136,0.04006368,0.000226,-0.000847152,-0.00000732,-0.000447,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +RESVVT-Bypass-Factor-fEWB&EDB,ResidentialVVVT,BiQuadratic,QRatio,EWB,EDB,0.85086272,0.014256792,0.000184,-0.014759136,-5.48e-06,0.000487,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +RESVVT-Cool-Cap-fEWB&OAT,ResidentialVVVT,BiQuadratic,QRatio,EWB,OAT,0.47523136,0.04006368,0.000226,-0.000847152,-7.32e-06,-0.000447,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 RESVVT-Cool-Cap-fRPM&OAT,ResidentialVVVT,BiQuadratic,QRatio,RPM,OAT,-686.394,-427.2546283,-66.38563967,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 RESVVT-Cool-CondFan-fPLR&OAT,ResidentialVVVT,BiQuadratic,,PLR,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 RESVVT-Cool-CycleLoss-fPLR,ResidentialVVVT,Linear,QRatio,PLR,,0.7,0.3,,,,,,,,,,,,,,,From .dat files included with MASControl2 @@ -477,79 +477,79 @@ RESVVT-Sens-Cap-fEWB&OAT,ResidentialVVVT,BiLinear,QRatio,EWB,OAT,2.78672,-0.0820 RESYS-Bypass-Factor-fAirflow,Residential#1,Quadratic,QRatio,Airflow,,-3.01,6.59,-2.57,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 RESYS-Bypass-Factor-fEWB&EDB,Residential#1,BiQuadratic,QRatio,EWB,EDB,-1.1641344,0.20453184,-0.000603,-0.03036096,0.00036,-0.001464804,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 RESYS-Bypass-Factor-fPLR,ResidentialVVVT,Linear,QRatio,PLR,,1,0,,,,,,,,,,,,,,,From .dat files included with MASControl2 -RESYS-Cool-Cap-fEWB&OAT,Residential#1,BiQuadratic,QRatio,EWB,OAT,0.7665024,0.01076904,-0.0000415,0.00133848,-0.000261,0.000457,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +RESYS-Cool-Cap-fEWB&OAT,Residential#1,BiQuadratic,QRatio,EWB,OAT,0.7665024,0.01076904,-4.15e-05,0.00133848,-0.000261,0.000457,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 RESYS-Cool-EIR-fEWB&OAT,Residential#1,BiQuadratic,EIRRatio,EWB,OAT,0.29770688,0.04314528,-0.000748,0.005972688,0.000482,-0.000956,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -RESYS-Cool-EIR-fPLR,,Cubic,EIRRatio,PLR,,0.0000626,1.18,-0.202,0.0263344,,,,,,,,,,,,,From .dat files included with MASControl2 +RESYS-Cool-EIR-fPLR,,Cubic,EIRRatio,PLR,,6.26e-05,1.18,-0.202,0.0263344,,,,,,,,,,,,,From .dat files included with MASControl2 RESYS-Heat-Cap-fEDB&OAT,Residential#1,BiQuadratic,QRatio,EDB,OAT,0.7516064,0,0,0.02799072,0.00019,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 RESYS-Heat-EIR-fEDB&OAT,Residential#1,BiQuadratic,EIRRatio,EDB,OAT,1.231072,0,0,-0.0334944,0.000739,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 RESYS-Heat-EIR-fPLR,Residential#1,Cubic,EIRRatio,PLR,,0.0857,0.939,-0.1834361,0.15897022,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 RESYS-Sens-Cap-fAirflow,Residential#1,Linear,QRatio,Airflow,,0.6,0.4,,,,,,,,,,,,,,,From .dat files included with MASControl2 -RESYS-Sens-Cap-fEWB&OAT,Residential#1,BiQuadratic,QRatio,EWB,OAT,3.3127968,-0.1617552,0.00184356,0.01027584,-0.000156,-0.0000284,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 +RESYS-Sens-Cap-fEWB&OAT,Residential#1,BiQuadratic,QRatio,EWB,OAT,3.3127968,-0.1617552,0.00184356,0.01027584,-0.000156,-2.84e-05,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 SAC Heating Coil PLF-FPLR,DX Heating Coil,Cubic,EIRRatio,QRatio,,0.8,0.2,0,0,,,,,,,0,1,,,,,From Prototype Buildings SchoolPrimary Kitchen_ZN_1_FLR_1_Case:1_WALKINFREEZERSingleShelfHorizontal_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.0236,0.0006,0,0,,,,,,,-35,20,,,,,From Prototype Buildings -SchoolPrimary Kitchen_ZN_1_FLR_1_Case:2_SELFCONTAINEDDISPLAYCASEMultiShelfVertical_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,6.02558E-05,1.23732E-06,,,,,,,-35,20,,,,,From Prototype Buildings -ScrewAir-Cap-fCHWT&DBT,Screw,BiQuadratic,QRatio,CHWT,DBT,0.97878647,0.02387169,0.000587,-0.0000478,-0.000112,-0.00011,,,,,,,,,,,From .dat files included with MASControl2 +SchoolPrimary Kitchen_ZN_1_FLR_1_Case:2_SELFCONTAINEDDISPLAYCASEMultiShelfVertical_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,6.02558e-05,1.23732e-06,,,,,,,-35,20,,,,,From Prototype Buildings +ScrewAir-Cap-fCHWT&DBT,Screw,BiQuadratic,QRatio,CHWT,DBT,0.97878647,0.02387169,0.000587,-4.78e-05,-0.000112,-0.00011,,,,,,,,,,,From .dat files included with MASControl2 ScrewAir-EIR-fCHWT&DBT,Screw,BiQuadratic,EIRRatio,CHWT,DBT,0.6729704,-0.005730012,0.000702,-0.00119601,0.00044,-0.000699,,,,,,,,,,,From .dat files included with MASControl2 -ScrewAir-EIR-fPLR&dT-1Comp/Ckt,Screw,BiQuadratic,EIRRatio,PLR,dT,0.01040687,1.05183303,-0.09462459,0.002943774,-0.0000252,-0.001085832,,,,,,,,,,,From .dat files included with MASControl2 -ScrewAir-EIR-fPLR&dT-2Comp/Ckt,Screw,BiQuadratic,EIRRatio,PLR,dT,0.09611014,0.72898877,0.19517007,-0.000729072,0.00000667,-0.000175,,,,,,,,,,,From .dat files included with MASControl2 -ScrewH2O-Cap-fCHWT&ECT,Screw,BiQuadratic,QRatio,CHWT,ECT,1.07096667,0.02693502,0.000768,-0.00643302,-0.0000949,-0.0000659,,,,,,,,,,,From .dat files included with MASControl2 +ScrewAir-EIR-fPLR&dT-1Comp/Ckt,Screw,BiQuadratic,EIRRatio,PLR,dT,0.01040687,1.05183303,-0.09462459,0.002943774,-2.52e-05,-0.001085832,,,,,,,,,,,From .dat files included with MASControl2 +ScrewAir-EIR-fPLR&dT-2Comp/Ckt,Screw,BiQuadratic,EIRRatio,PLR,dT,0.09611014,0.72898877,0.19517007,-0.000729072,6.67e-06,-0.000175,,,,,,,,,,,From .dat files included with MASControl2 +ScrewH2O-Cap-fCHWT&ECT,Screw,BiQuadratic,QRatio,CHWT,ECT,1.07096667,0.02693502,0.000768,-0.00643302,-9.49e-05,-6.59e-05,,,,,,,,,,,From .dat files included with MASControl2 ScrewH2O-EIR-fCHWT&ECT,Screw,BiQuadratic,EIRRatio,CHWT,ECT,0.59849788,-0.00123345,0.000563,0.001602738,0.000636,-0.001094148,,,,,,,,,,,From .dat files included with MASControl2 -ScrewH2O-EIR-fPLR&dT-1Comp/Ckt,Screw,BiQuadratic,EIRRatio,PLR,dT,-0.11699212,1.2635448,-0.2194667,0.005301648,0.0000547,-0.003346506,,,,,,,,,,,From .dat files included with MASControl2 +ScrewH2O-EIR-fPLR&dT-1Comp/Ckt,Screw,BiQuadratic,EIRRatio,PLR,dT,-0.11699212,1.2635448,-0.2194667,0.005301648,5.47e-05,-0.003346506,,,,,,,,,,,From .dat files included with MASControl2 ScrewH2O-EIR-fPLR&dT-2Comp/Ckt,Screw,BiQuadratic,EIRRatio,PLR,dT,-0.27111483,1.49009538,-0.33198115,0.017556084,-0.000191,-0.008247186,,,,,,,,,,,From .dat files included with MASControl2 ScrewRemote-Cap-fCHWT&SCT,Screw,BiQuadratic,QRatio,CHWT,SCT,1.16410009,0.048370122,0.000493,-0.002428218,-0.000109,-0.000269,,,,,,,,,,,From .dat files included with MASControl2 ScrewRemote-EIR-fCHWT&SCT,Screw,BiQuadratic,EIRRatio,CHWT,SCT,0.79518287,-0.009101466,0.001707804,-0.015352632,0.000488,-0.000932,,,,,,,,,,,From .dat files included with MASControl2 ScrewRemote-EIR-fPLR-1Comp/Ckt,Screw,Quadratic,EIRRatio,PLR,,0.07043035,1.01683199,-0.08726242,,,,,,,,,,,,,,From .dat files included with MASControl2 ScrewRemote-EIR-fPLR-2Comp/Ckt,Screw,Quadratic,EIRRatio,PLR,,0.08138224,0.72724819,0.19136968,,,,,,,,,,,,,,From .dat files included with MASControl2 -ScrollChlrAirCoolCap-fCHW&OAT,Chiller,BiQuadratic,QRatio,CHWT,OAT,1.05229229,0.033560892,0.000215,-0.005180832,-0.0000442,-0.000215,,,,,,,,,,,From .dat files included with MASControl2 +ScrollChlrAirCoolCap-fCHW&OAT,Chiller,BiQuadratic,QRatio,CHWT,OAT,1.05229229,0.033560892,0.000215,-0.005180832,-4.42e-05,-0.000215,,,,,,,,,,,From .dat files included with MASControl2 ScrollChlrAirCoolEIR-fCHW&OAT,Chiller,BiQuadratic,EIRRatio,CHWT,OAT,0.58333562,-0.004036194,0.000468,-0.000224478,0.000481,-0.000682,,,,,,,,,,,From .dat files included with MASControl2 ScrollChlrAirCoolEIR-fPLR,Chiller,Quadratic,EIRRatio,PLR,,0.03366649,0.53152555,0.43480802,,,,,,,,,,,,,,From .dat files included with MASControl2 Si-Film_Spectral-fAirMass,PV-Module,Cubic,,AirMass,,0.95691782,0.04079713,-0.00869376,0.00042887,,,,,,,,,,,,,From .dat files included with MASControl2 Single Shelf Horizontal Latent Energy Multiplier_After2004,Refrigerated Case,Cubic,,,,0.0236,0.0006,0,0,,,,,,,-35,20,,,,,From Reference Buildings -Single Shelf Horizontal Latent Energy Multiplier_Pre2004,Refrigerated Case,Cubic,,,,0.020376,0.00024378,0.0000114,1.811E-07,,,,,,,-35,20,,,,,From Reference Buildings +Single Shelf Horizontal Latent Energy Multiplier_Pre2004,Refrigerated Case,Cubic,,,,0.020376,0.00024378,1.14e-05,1.811e-07,,,,,,,-35,20,,,,,From Reference Buildings Single zone VAV fan,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.027827882,0.026583195,-0.0870687,1.03091975,,,,,,,0,1,,,0.1,,Baseline for System Type 11 from ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method Small-CHW-Bypass-fAirflow,CHWCoils,Quadratic,QRatio,Airflow,,-0.718,1.91,-0.189,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Small-CHW-Coil-Bypass-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,1.09657216,0.001908,0.000369,-0.005647032,0.0000246,-0.000277,,,,,15.55556,29.44444,12.77778,29.44444,,,From .dat files included with MASControl2 +Small-CHW-Coil-Bypass-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,1.09657216,0.001908,0.000369,-0.005647032,2.46e-05,-0.000277,,,,,15.55556,29.44444,12.77778,29.44444,,,From .dat files included with MASControl2 Small-CHW-Coil-Cap-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,-0.282048,-0.022212,0.0054432,0.0297216,0.000804,-0.0033372,,,,,15.55556,29.44444,12.77778,29.44444,,,From .dat files included with MASControl2 Small-CHW-Sens-Cap-fAirflow,CHWCoils,Quadratic,QRatio,Airflow,,0.155,1.01,-0.16,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 Small-CHW-Sens-Cap-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,-0.415152,-0.0405576,0.00140616,0.086508,0.000444,-0.00184356,,,,,12.77778,29.44444,12.77778,29.44444,,,From .dat files included with MASControl2 -Smooth_Optical-fAOI,PV-Module,Cubic,,AOI,,3.76248479,-0.15946805,0.00302191,-0.0000191,,,,,,,,,,,,,From .dat files included with MASControl2 +Smooth_Optical-fAOI,PV-Module,Cubic,,AOI,,3.76248479,-0.15946805,0.00302191,-1.91e-05,,,,,,,,,,,,,From .dat files included with MASControl2 Split DX Coil EIR-FF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.1552,-0.1808,0.0256,,,,,,,,0.5,1.5,,,,,"From PNNL Prototype Buildings ApartmentMidRise, HotelSmall, Warehouse" SpltAC1Sp_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 SpltAC1Sp_BF_fT,BF_fT,BiQuadratic,,T,T,8.513632,-0.630072,0.0165888,-0.0450144,0.00107892,-0.0018954,,,,,,,,,0,3.33,From .dat files included with MASControl2 -SpltAC1Sp_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0.00007,1.23,-0.307,0.0756,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,7e-05,1.23,-0.307,0.0756,,,,,,,,,,,,,From .dat files included with MASControl2 SpltAC1Sp_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,0.00012,1.2,-0.261,0.0596,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.00007,1.17,-0.213,0.0438,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,0.67916,0.016938,0.00069336,0.0045576,-0.0000842,-0.00047628,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC1Sp_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-7e-05,1.17,-0.213,0.0438,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,0.67916,0.016938,0.00069336,0.0045576,-8.42e-05,-0.00047628,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 SpltAC1Sp_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.805,0.233,-0.038,,,,,,,,,,,,,,From .dat files included with MASControl2 SpltAC1Sp_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.827,0.203,-0.03,,,,,,,,,,,,,,From .dat files included with MASControl2 SpltAC1Sp_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.852,0.17,-0.0219,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.7311616,-0.10297296,0.00093636,0.00477864,-0.0000907,-0.000202824,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.7311616,-0.10297296,0.00093636,0.00477864,-9.07e-05,-0.000202824,,,,,,,,,,,From .dat files included with MASControl2 SpltAC1Sp_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.7390464,-0.00778968,0.000128304,-0.00027,0.0006642,-0.000648,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 SpltAC1Sp_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 SpltAC1Sp_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 SpltAC1Sp-ge45_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 SpltAC1Sp-ge45_BF_fT,BF_fT,BiQuadratic,,T,T,16.900064,-1.747584,0.050544,0.1428912,0.00048924,-0.0090396,,,,,,,,,0,3.76,From .dat files included with MASControl2 SpltAC1Sp-ge45_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0,1.18,-0.223,0.0468,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-ge45_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,0.00008,1.15,-0.183,0.0343,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-ge45_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,8e-05,1.15,-0.183,0.0343,,,,,,,,,,,,,From .dat files included with MASControl2 SpltAC1Sp-ge45_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.0001,1.12,-0.14,0.0225,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-ge45_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.2403136,-0.0346752,0.00187596,0.00106848,-0.000057,-0.0003564,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC1Sp-ge45_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.2403136,-0.0346752,0.00187596,0.00106848,-5.7e-05,-0.0003564,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 SpltAC1Sp-ge45_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.847,0.177,-0.0235,,,,,,,,,,,,,,From .dat files included with MASControl2 SpltAC1Sp-ge45_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.869,0.149,-0.0172,,,,,,,,,,,,,,From .dat files included with MASControl2 SpltAC1Sp-ge45_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.893,0.118,-0.0112,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-ge45_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.8260768,0.0199944,-0.00284148,-0.01422576,-0.0000577,0.00064152,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-ge45_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.8260768,0.0199944,-0.00284148,-0.01422576,-5.77e-05,0.00064152,,,,,,,,,,,From .dat files included with MASControl2 SpltAC1Sp-ge45_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.093776,0.0674784,-0.00192132,-0.0031176,0.00067068,-0.0005832,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 SpltAC1Sp-ge45_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 SpltAC1Sp-ge45_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 SpltAC1Sp-lt45_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 SpltAC1Sp-lt45_BF_fT,BF_fT,BiQuadratic,,T,T,22.932224,-2.291616,0.063504,0.0800712,0.00076464,-0.0068364,,,,,,,,,0,3.3,From .dat files included with MASControl2 SpltAC1Sp-lt45_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0,1.18,-0.223,0.0468,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-lt45_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,0.00008,1.15,-0.183,0.0343,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-lt45_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,8e-05,1.15,-0.183,0.0343,,,,,,,,,,,,,From .dat files included with MASControl2 SpltAC1Sp-lt45_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.0001,1.12,-0.14,0.0225,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-lt45_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.1299744,-0.0222336,0.0015228,-0.0000353,-0.0000434,-0.00032724,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC1Sp-lt45_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.1299744,-0.0222336,0.0015228,-3.53e-05,-4.34e-05,-0.00032724,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 SpltAC1Sp-lt45_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.847,0.177,-0.0235,,,,,,,,,,,,,,From .dat files included with MASControl2 SpltAC1Sp-lt45_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.869,0.149,-0.0172,,,,,,,,,,,,,,From .dat files included with MASControl2 SpltAC1Sp-lt45_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.893,0.118,-0.0112,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-lt45_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.4985024,0.0478512,-0.0034992,-0.01084968,-0.0000548,0.00047628,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC1Sp-lt45_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.4985024,0.0478512,-0.0034992,-0.01084968,-5.48e-05,0.00047628,,,,,,,,,,,From .dat files included with MASControl2 SpltAC1Sp-lt45_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.09712,0.0536256,-0.00144828,0.0040644,0.00062208,-0.000729,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 SpltAC1Sp-lt45_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 SpltAC1Sp-lt45_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 @@ -558,7 +558,7 @@ SpltAC2SpHiSEER_BF_fT,BF_fT,BiQuadratic,,T,T,20.03024,-1.922832,0.051516,0.08618 SpltAC2SpHiSEER_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0.00635,1.12,-0.139,0.016,,,,,,,,,,,,,From .dat files included with MASControl2 SpltAC2SpHiSEER_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,-0.00144,1.12,-0.14,0.022,,,,,,,,,,,,,From .dat files included with MASControl2 SpltAC2SpHiSEER_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.00726,1.11,-0.132,0.0262,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpHiSEER_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.5240096,-0.0665928,0.00299376,0.00162288,-0.0000651,-0.00048924,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC2SpHiSEER_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.5240096,-0.0665928,0.00299376,0.00162288,-6.51e-05,-0.00048924,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 SpltAC2SpHiSEER_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.923,0.153,-0.0156,,,,,,,,,,,,,,From .dat files included with MASControl2 SpltAC2SpHiSEER_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.94,0.124,-0.0109,,,,,,,,,,,,,,From .dat files included with MASControl2 SpltAC2SpHiSEER_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.959,0.0934,-0.00688,,,,,,,,,,,,,,From .dat files included with MASControl2 @@ -571,16 +571,16 @@ SpltAC2SpLoSEER_BF_fT,BF_fT,BiQuadratic,,T,T,10.820416,-1.041264,0.0254988,0.229 SpltAC2SpLoSEER_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,-0.00016,1.12,-0.143,0.0206,,,,,,,,,,,,,From .dat files included with MASControl2 SpltAC2SpLoSEER_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,-0.00146,1.1,-0.119,0.0176,,,,,,,,,,,,,From .dat files included with MASControl2 SpltAC2SpLoSEER_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,0.00284,1.06,-0.0687,0.00523,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpLoSEER_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.54887488,-0.0648072,0.00310068,-0.000425376,-0.0000255,-0.00060264,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltAC2SpLoSEER_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.54887488,-0.0648072,0.00310068,-0.000425376,-2.55e-05,-0.00060264,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 SpltAC2SpLoSEER_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.856,0.121,-0.0124,,,,,,,,,,,,,,From .dat files included with MASControl2 SpltAC2SpLoSEER_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.872,0.0941,-0.00752,,,,,,,,,,,,,,From .dat files included with MASControl2 SpltAC2SpLoSEER_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.889,0.0695,-0.00646,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpLoSEER_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.322048,-0.0286956,-0.00124092,-0.020124,-0.0000405,0.0006804,,,,,,,,,,,From .dat files included with MASControl2 +SpltAC2SpLoSEER_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.322048,-0.0286956,-0.00124092,-0.020124,-4.05e-05,0.0006804,,,,,,,,,,,From .dat files included with MASControl2 SpltAC2SpLoSEER_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,-0.281376,0.1343088,-0.0036936,-0.0173736,0.00096552,-0.00075168,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 SpltAC2SpLoSEER_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 SpltAC2SpLoSEER_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 SpltACEvap_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 -SpltACEvap_BF_fT,BF_fT,BiQuadratic,,T,T,16.06,-1.566,0.0405,1.75E-10,3.24E-12,3.24E-12,,,,,,,,,0,3.97,From .dat files included with MASControl2 +SpltACEvap_BF_fT,BF_fT,BiQuadratic,,T,T,16.06,-1.566,0.0405,1.75e-10,3.24e-12,3.24e-12,,,,,,,,,0,3.97,From .dat files included with MASControl2 SpltACEvap_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0,1,0,0,,,,,,,,,,,,,From .dat files included with MASControl2 SpltACEvap_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,0,1,0,0,,,,,,,,,,,,,From .dat files included with MASControl2 SpltACEvap_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,0,1,0,0,,,,,,,,,,,,,From .dat files included with MASControl2 @@ -594,53 +594,53 @@ SpltACEvap_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.3 SpltACEvap_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 SpltHP1SpCom_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 SpltHP1SpCom_BF_fT,BF_fT,BiQuadratic,,T,T,8.513632,-0.630072,0.0165888,-0.0450144,0.00107892,-0.0018954,,,,,,,,,0,3.33,From .dat files included with MASControl2 -SpltHP1SpCom_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0.00007,1.23,-0.307,0.0756,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpCom_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,7e-05,1.23,-0.307,0.0756,,,,,,,,,,,,,From .dat files included with MASControl2 SpltHP1SpCom_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,0.00012,1.2,-0.261,0.0596,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpCom_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.00007,1.17,-0.213,0.0438,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpCom_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,0.67916,0.016938,0.00069336,0.0045576,-0.0000842,-0.00047628,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltHP1SpCom_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-7e-05,1.17,-0.213,0.0438,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpCom_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,0.67916,0.016938,0.00069336,0.0045576,-8.42e-05,-0.00047628,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 SpltHP1SpCom_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.805,0.233,-0.038,,,,,,,,,,,,,,From .dat files included with MASControl2 SpltHP1SpCom_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.827,0.203,-0.03,,,,,,,,,,,,,,From .dat files included with MASControl2 SpltHP1SpCom_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.852,0.17,-0.0219,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpCom_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.7311616,-0.10297296,0.00093636,0.00477864,-0.0000907,-0.000202824,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpCom_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.7311616,-0.10297296,0.00093636,0.00477864,-9.07e-05,-0.000202824,,,,,,,,,,,From .dat files included with MASControl2 SpltHP1SpCom_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.7390464,-0.00778968,0.000128304,-0.00027,0.0006642,-0.000648,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 SpltHP1SpCom_HIR_fT,HIR_fT,BiQuadratic,,T,T,0.8186976,0.01406952,0.000117936,-0.01579104,0.000222264,-0.000300024,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltHP1SpCom_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0.85516576,-0.003631392,-0.00000619,0.02644704,0.00041148,-0.000141264,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltHP1SpCom_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0.85516576,-0.003631392,-6.19e-06,0.02644704,0.00041148,-0.000141264,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 SpltHP1SpRes_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 SpltHP1SpRes_BF_fT,BF_fT,BiQuadratic,,T,T,8.513632,-0.630072,0.0165888,-0.0450144,0.00107892,-0.0018954,,,,,,,,,0,3.33,From .dat files included with MASControl2 -SpltHP1SpRes_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0.00007,1.23,-0.307,0.0756,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpRes_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,7e-05,1.23,-0.307,0.0756,,,,,,,,,,,,,From .dat files included with MASControl2 SpltHP1SpRes_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,0.00012,1.2,-0.261,0.0596,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpRes_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.00007,1.17,-0.213,0.0438,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpRes_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,0.67916,0.016938,0.00069336,0.0045576,-0.0000842,-0.00047628,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltHP1SpRes_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-7e-05,1.17,-0.213,0.0438,,,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpRes_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,0.67916,0.016938,0.00069336,0.0045576,-8.42e-05,-0.00047628,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 SpltHP1SpRes_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.805,0.233,-0.038,,,,,,,,,,,,,,From .dat files included with MASControl2 SpltHP1SpRes_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.827,0.203,-0.03,,,,,,,,,,,,,,From .dat files included with MASControl2 SpltHP1SpRes_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.852,0.17,-0.0219,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpRes_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.7311616,-0.10297296,0.00093636,0.00477864,-0.0000907,-0.000202824,,,,,,,,,,,From .dat files included with MASControl2 +SpltHP1SpRes_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.7311616,-0.10297296,0.00093636,0.00477864,-9.07e-05,-0.000202824,,,,,,,,,,,From .dat files included with MASControl2 SpltHP1SpRes_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.7390464,-0.00778968,0.000128304,-0.00027,0.0006642,-0.000648,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 SpltHP1SpRes_HIR_fT,HIR_fT,BiQuadratic,,T,T,0.9003872,0.01108728,0.0001701,-0.02579472,0.0008424,-0.000290628,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltHP1SpRes_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0.9303344,-0.0064656,0.0000177,0.02813472,-0.00000551,-0.000208656,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltHP1SpRes_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0.9303344,-0.0064656,1.77e-05,0.02813472,-5.51e-06,-0.000208656,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 SpltHP2Sp_BF_fFlow,BF_fFlow,Linear,,Flow,,1.75,-1578.5656,,,,,,,,,,,,,1,1.189,From .dat files included with MASControl2 SpltHP2Sp_BF_fT,BF_fT,BiQuadratic,,T,T,20.03024,-1.922832,0.051516,0.086184,0.0011502,-0.0076788,,,,,,,,,0,3.92,From .dat files included with MASControl2 SpltHP2Sp_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0.00635,1.12,-0.139,0.016,,,,,,,,,,,,,From .dat files included with MASControl2 SpltHP2Sp_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,-0.00144,1.12,-0.14,0.022,,,,,,,,,,,,,From .dat files included with MASControl2 SpltHP2Sp_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.00726,1.11,-0.132,0.0262,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP2Sp_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.5240096,-0.0665928,0.00299376,0.00162288,-0.0000651,-0.00048924,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SpltHP2Sp_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.5240096,-0.0665928,0.00299376,0.00162288,-6.51e-05,-0.00048924,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 SpltHP2Sp_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.923,0.153,-0.0156,,,,,,,,,,,,,,From .dat files included with MASControl2 SpltHP2Sp_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.94,0.124,-0.0109,,,,,,,,,,,,,,From .dat files included with MASControl2 SpltHP2Sp_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.959,0.0934,-0.00688,,,,,,,,,,,,,,From .dat files included with MASControl2 SpltHP2Sp_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.54,0.0382752,-0.00297756,-0.0114912,-0.00010044,0.0005346,,,,,,,,,,,From .dat files included with MASControl2 SpltHP2Sp_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,-0.172512,0.1176624,-0.00324,-0.01152,0.00077112,-0.00057024,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 SpltHP2Sp_HIR_fT,HIR_fT,BiQuadratic,,T,T,0.9272864,0.00802008,0.000201528,-0.02177136,0.000729,-0.000303264,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltHP2Sp_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0.8756304,-0.00466344,1.62E-14,0.02912976,0.00012636,-0.000163296,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SteamTurbine-Flow-fPSIG,SteamTurbineGen,BiQuadratic,QRatio,PSIG,PSIG,38.79236,-0.0000307,1.11E-11,0.000147951,1.93E-11,-7.36E-11,,,,,,,,,18,100,From .dat files included with MASControl2 +SpltHP2Sp_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0.8756304,-0.00466344,1.62e-14,0.02912976,0.00012636,-0.000163296,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 +SteamTurbine-Flow-fPSIG,SteamTurbineGen,BiQuadratic,QRatio,PSIG,PSIG,38.79236,-3.07e-05,1.11e-11,0.000147951,1.93e-11,-7.36e-11,,,,,,,,,18,100,From .dat files included with MASControl2 SteamTurbine-HIR-fPLR,SteamTurbineGen,Quadratic,,PLR,,0.12838545,0.90049523,-0.02888074,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Stippled_Optical-fAOI,PV-Module,Cubic,,AOI,,4.70208168,-0.21138079,0.00393233,-0.000024,,,,,,,,,,,,,From .dat files included with MASControl2 +Stippled_Optical-fAOI,PV-Module,Cubic,,AOI,,4.70208168,-0.21138079,0.00393233,-2.4e-05,,,,,,,,,,,,,From .dat files included with MASControl2 SWH-EFFFPLR-NECB2011,Water Heater,Cubic,FIRRatio,QRatio,,0.7576,1.0071,-1.4443,0.6844,,,,,,,0,1,,,,,From NECB 2011 Tower_Fan_Curve,,Cubic,,,,0,0,0,1,,,,,,,0,1,,,,,From Prototype Buildings Transformer-Loss-fPLR,ElecMeters,Linear,QRatio,PLR,,0.1,0.9,,,,,,,,,,,,,,,From .dat files included with MASControl2 Two-Speed Fan EIR fPLR,FanEIR-FPLR,Linear,,PLR,,-0.764706,1.764706,,,,,,,,,,,,,0.4,,From .dat files included with MASControl2 TwoSpeedFan,FanEIR-FPLR,Cubic,EIRRatio,PLR,,0.000281,-0.0579,0.586,0.471,,,,,,,,,,,,,From .dat files included with MASControl2 Typical VSD Fan,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.047182815,0.130541742,-0.117286942,0.940313747,,,,,,,0,1,,,0.1,,"From California Energy Commision, ""Advanced Variable Air Volume System Design Guide,"" October 2003" -TypicalCyclingAC-EIR-fPLR,CyclingAC,Cubic,EIRRatio,PLR,,0.0000626,1.17517,-0.201513,0.0263344,,,,,,,,,,,,,From .dat files included with MASControl2 +TypicalCyclingAC-EIR-fPLR,CyclingAC,Cubic,EIRRatio,PLR,,6.26e-05,1.17517,-0.201513,0.0263344,,,,,,,,,,,,,From .dat files included with MASControl2 Vane Axial w Var Pitch FPLR,FanEIR-FPLR,Quadratic,,PLR,,0.212048,-0.569286,1.345238,,,,,,,,,,,,0.15,1,From .dat files included with MASControl2 Variable Speed Drive FPLR,FanEIR-FPLR,Quadratic,,PLR,,0.219762,-0.874784,1.652597,,,,,,,,,,,,0.1,1,From .dat files included with MASControl2 VarVolFan-AFBIFanCurve-NECB2011-FPLR,Fan,Cubic,PwrRatio,FlowRatio,,-2.4176,9.5874,-11.559,5.4009,,,,,,,0.68,1,,,,,From NECB 2011 @@ -648,76 +648,76 @@ VarVolFan-AFBIInletVanes-NECB2011-FPLR,Fan,Cubic,PwrRatio,FlowRatio,,-4.1457,16. VarVolFan-FCInletVanes-NECB2011-FPLR,Fan,Cubic,PwrRatio,FlowRatio,,-0.3477,4.0976,-5.0024,2.268,,,,,,,0.22,1,,,,,From NECB 2011 VarVolFan-VSD-NECB2011-FPLR,Fan,Cubic,PwrRatio,FlowRatio,,0.1389,1.7699,-1.615,0.6996,,,,,,,0.04,1,,,,,From NECB 2011 VFD-Loss-fPLR,Pumps,Linear,QRatio,PLR,,0.6,0.4,,,,,,,,,,,,,,,From .dat files included with MASControl2 -VRF-HP-Resys-ClCap-fSST&ODB,CondUnit,BiQuadratic,QRatio,SST,ODB,1.26588416,0,0,-0.007582032,-0.00000214,0,,,,,,,,,,,From .dat files included with MASControl2 +VRF-HP-Resys-ClCap-fSST&ODB,CondUnit,BiQuadratic,QRatio,SST,ODB,1.26588416,0,0,-0.007582032,-2.14e-06,0,,,,,,,,,,,From .dat files included with MASControl2 VRF-HP-Resys-ClEIR-fSST&ODB,CondUnit,BiQuadratic,EIRRatio,SST,ODB,0.384832,0,0,0.0092304,0.000238,0,,,,,,,,,,,From .dat files included with MASControl2 VRF-HP-Resys-Crankcase-fPLR,CondUnit,Quadratic,,PLR,,1,-1.72,0.72,,,,,,,,,,,,,,From .dat files included with MASControl2 VRF-HP-Resys-Cycle-fPLR,CondUnit,Linear,QRatio,PLR,,0.898,0.102,,,,,,,,,,,,,,,From .dat files included with MASControl2 -VRF-HP-Resys-HtCap-fSCT&OWB,CondUnit,BiQuadratic,QRatio,SCT,OWB,0.89783456,0,0,0.016707888,0.000000616,0,,,,,,,,,,,From .dat files included with MASControl2 -VRF-HP-Resys-HtEIR-fSCT&OWB,CondUnit,BiQuadratic,EIRRatio,SCT,OWB,1.0525344,0,0,-0.00815688,-0.0000872,0,,,,,,,,,,,From .dat files included with MASControl2 +VRF-HP-Resys-HtCap-fSCT&OWB,CondUnit,BiQuadratic,QRatio,SCT,OWB,0.89783456,0,0,0.016707888,6.16e-07,0,,,,,,,,,,,From .dat files included with MASControl2 +VRF-HP-Resys-HtEIR-fSCT&OWB,CondUnit,BiQuadratic,EIRRatio,SCT,OWB,1.0525344,0,0,-0.00815688,-8.72e-05,0,,,,,,,,,,,From .dat files included with MASControl2 VSD-TWR-FAN-FPLR,Cooling Tower,Cubic,,,,0.33162901,-0.88567609,0.60556507,0.9484823,,,,,,,0,1,,,,,From PNNL PRM Reference Manual Water-Cooled-Bypass-fAirflow,"DXCooling,WCC",Cubic,QRatio,Airflow,,0.9,-3.73,7.37,-3.54,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 Water-Cooled-Bypass-fEWB&EWT,"DXCooling,WCC",BiQuadratic,QRatio,EWB,EWT,-5.51104768,0.73563552,-0.0185004,0.142520616,0.000942,-0.010213452,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -Water-Cooled-Cool-Cap-fEWB&EWT,"DXCooling,WCC",BiQuadratic,QRatio,EWB,EWT,0.8254384,0.00574416,0.000735,-0.00310374,-0.0000146,-0.000194,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 +Water-Cooled-Cool-Cap-fEWB&EWT,"DXCooling,WCC",BiQuadratic,QRatio,EWB,EWT,0.8254384,0.00574416,0.000735,-0.00310374,-1.46e-05,-0.000194,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 Water-Cooled-EIR-fEWB&EWT,"DXCooling,WCC",BiQuadratic,EIRRatio,EWB,EWT,0.0985984,0.062604,-0.00184356,0.01183032,0.000292,-0.000395,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 Water-Cooled-EIR-fPLR,"DXCooling,WCC",Cubic,EIRRatio,PLR,,0.201,-0.0312,1.9504979,-1.1205104,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Water-Cooled-Sens-Cap-fEWB&EWT,"DXCooling,WCC",BiQuadratic,QRatio,EWB,EWT,2.1542784,-0.0242784,-0.00148716,-0.00829548,-0.0000296,0.000272,,,,,12.77778,29.44444,10,46.11111,,,From .dat files included with MASControl2 +Water-Cooled-Sens-Cap-fEWB&EWT,"DXCooling,WCC",BiQuadratic,QRatio,EWB,EWT,2.1542784,-0.0242784,-0.00148716,-0.00829548,-2.96e-05,0.000272,,,,,12.77778,29.44444,10,46.11111,,,From .dat files included with MASControl2 WaterCooled_Centrifugal_CAPFT_NECB2011,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.707908,-0.00200657,-0.00259605,0.0300588,-0.00105643,0.0020457,,,,,5,10,24,35,,,From NECB 2011 -WaterCooled_Centrifugal_Chiller_150TO300_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_150TO300_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_150TO300_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_150TO300_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_150TO300_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_150TO300_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.7600172,0.0147432,0.0002144,0.0207218,-0.0006425,0.0008007,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.6772577,0.0117857,-0.0001967,0.0014414,0.0003005,-0.0006807,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.536234,0.005581,-0.0013654,0.0488966,-0.0012018,0.0010523,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,1.0821822,0.0042977,-0.0013182,-0.0260781,0.0008256,-0.0006013,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_300TO600_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_300TO600_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_AllCapacities_2004_2007_2010_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010. EIRFPLR curve is identical for all WaterCooled Chillers" +WaterCooled_Centrifugal_Chiller_300TO600_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_300TO600_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_AllCapacities_2004_2007_2010_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010. EIRFPLR curve is identical for all WaterCooled Chillers" WaterCooled_Centrifugal_Chiller_GT150_2004_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.7600172,0.0147432,0.0002144,0.0207218,-0.0006425,0.0008007,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." WaterCooled_Centrifugal_Chiller_GT150_2004_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.6772577,0.0117857,-0.0001967,0.0014414,0.0003005,-0.0006807,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_GT300_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_GT600_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_GT600_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_LT150_2004_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.7446451,0.0114858,0.0000148,0.022401,-0.000688,0.0009839,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.772877,0.022101,-0.0000799,-0.0070045,0.0004763,-0.0010612,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_LT150_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_LT150_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_GT300_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_GT600_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_GT600_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_LT150_2004_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.7446451,0.0114858,1.48e-05,0.022401,-0.000688,0.0009839,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.772877,0.022101,-7.99e-05,-0.0070045,0.0004763,-0.0010612,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_LT150_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_Chiller_LT150_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." WaterCooled_Centrifugal_EIRFPLR_NECB2011,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.171493,0.588202,0.237373,,,,,,,,0,1,,,,,From NECB 2011 -WaterCooled_Centrifugal_EIRFT_NECB2011,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.560523,-0.0137816,6.56424E-05,0.0132194,0.000268596,-0.000501131,,,,,5,10,24,35,,,From NECB 2011 -WaterCooled_PositiveDisplacement_Chiller_150TO300_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_150TO300_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_150TO300_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_2004_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.906115,0.029227,-0.0003647,-0.0009709,-0.0000905,0.0002527,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Centrifugal_EIRFT_NECB2011,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.560523,-0.0137816,6.56424e-05,0.0132194,0.000268596,-0.000501131,,,,,5,10,24,35,,,From NECB 2011 +WaterCooled_PositiveDisplacement_Chiller_150TO300_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_150TO300_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_150TO300_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_2004_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.906115,0.029227,-0.0003647,-0.0009709,-9.05e-05,0.0002527,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." WaterCooled_PositiveDisplacement_Chiller_2004_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.3617105,-0.0229833,0.0009519,0.0131889,0.0003752,-0.0007059,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_2010_PathB_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.9061171,0.0292267,-0.0003665,-0.0009698,-0.0000907,0.0002535,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_2010_PathB_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.9061171,0.0292267,-0.0003665,-0.0009698,-9.07e-05,0.0002535,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." WaterCooled_PositiveDisplacement_Chiller_2010_PathB_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.3617782,-0.0230016,0.0009672,0.0131801,0.0003761,-0.0007121,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_75TO150_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_75TO150_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_75TO150_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.906115,0.0292277,-0.0003647,-0.0009709,-0.0000905,0.0002527,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_75TO150_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_75TO150_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_75TO150_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.906115,0.0292277,-0.0003647,-0.0009709,-9.05e-05,0.0002527,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.3773115,-0.0229032,0.0016504,0.0118156,0.0004345,-0.0010132,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_GT300_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_GT300_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_GT300_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.906115,0.0292277,-0.0003647,-0.0009709,-0.0000905,0.0002527,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_GT300_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_GT300_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_GT300_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.906115,0.0292277,-0.0003647,-0.0009709,-9.05e-05,0.0002527,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.3617105,-0.0229833,0.0009519,0.0131889,0.0003752,-0.0007059,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_LT75_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_LT75_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_LT75_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Reciprocating_CAPFT_NECB2011,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.03031,0.0334698,0.00023639,-0.00729587,-0.000023166,-0.000148943,,,,,5,10,24,35,,,From NECB 2011 +WaterCooled_PositiveDisplacement_Chiller_LT75_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_LT75_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_PositiveDisplacement_Chiller_LT75_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." +WaterCooled_Reciprocating_CAPFT_NECB2011,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.03031,0.0334698,0.00023639,-0.00729587,-2.3166e-05,-0.000148943,,,,,5,10,24,35,,,From NECB 2011 WaterCooled_Reciprocating_EIRFPLR_NECB2011,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.081441,0.419271,0.499396,,,,,,,,0,1,,,,,From NECB 2011 WaterCooled_Reciprocating_EIRFT_NECB2011,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.499699,-0.0130841,0.000266425,0.0165925,0.000185393,-0.000375646,,,,,5,10,24,35,,,From NECB 2011 WaterCooled_Screw_CAPFT_NECB2011,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.812998,-0.0142532,-0.00161799,0.0263844,-0.00091543,0.00169601,,,,,5,10,24,35,,,From NECB 2011 WaterCooled_Screw_EIRFPLR_NECB2011,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.330188,0.235543,0.460708,,,,,,,,0,1,,,,,From NECB 2011 WaterCooled_Screw_EIRFT_NECB2011,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.638103,0.00630158,0.00092327,-0.00455294,0.000825682,-0.00156152,,,,,5,10,24,35,,,From NECB 2011 -WaterCooled_Scroll_CAPFT_NECB2011,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.94418,0.0337102,9.75564E-05,-0.00322114,-4.91832E-05,-0.000177584,,,,,5,10,24,35,,,From NECB 2011 +WaterCooled_Scroll_CAPFT_NECB2011,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.94418,0.0337102,9.75564e-05,-0.00322114,-4.91832e-05,-0.000177584,,,,,5,10,24,35,,,From NECB 2011 WaterCooled_Scroll_EIRFPLR_NECB2011,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.04412,0.640367,0.319555,,,,,,,,0,1,,,,,From NECB 2011 WaterCooled_Scroll_EIRFT_NECB2011,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.727393,-0.0118922,0.000541177,0.00187934,0.000473461,-0.000711472,,,,,5,10,24,35,,,From NECB 2011 -WC Screw Default 90.1-2004 Cap_fTWC,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.906115,0.0292277,-0.0003647,-0.0009709,-0.0000905,0.0002527,,,,,0,20,0,50,,,From RefBldgLargeOfficePost1980 & Pre1980 +WC Screw Default 90.1-2004 Cap_fTWC,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.906115,0.0292277,-0.0003647,-0.0009709,-9.05e-05,0.0002527,,,,,0,20,0,50,,,From RefBldgLargeOfficePost1980 & Pre1980 WC Screw Default 90.1-2004 EIR_fT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.3617105,-0.0229833,-0.0009519,0.0131889,0.0003752,-0.0007059,,,,,0,20,0,50,,,From RefBldgLargeOfficePost1980 % Pre1980 -WC Screw GTE 300tons Default 90.1-2004 EIR_fPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.2737954,0.02822257,-8.09766E-05,0.9612284,0.3029741,-0.02421933,0,-0.03885224,0,0,18.54,31.63,0.2,1.02,,,From RefBldgLargeOfficePost1980 & Pre1980 -WC_PD_2004_CAPFT,,BiQuadratic,,,,0.906115,0.0292277,-0.0003647,-0.0009709,-0.0000905,0.0002527,,,,,5,10,17.78,46.11,,,From PNNL Prototype Hospital -WC_PD_2010_PB_CAPFT,,BiQuadratic,,,,0.9061171,0.0292267,-0.0003665,-0.0009698,-0.0000907,0.0002535,,,,,5,10,17.78,46.11,,,From PNNL Prototype OfficeLarge +WC Screw GTE 300tons Default 90.1-2004 EIR_fPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.2737954,0.02822257,-8.09766e-05,0.9612284,0.3029741,-0.02421933,0,-0.03885224,0,0,18.54,31.63,0.2,1.02,,,From RefBldgLargeOfficePost1980 & Pre1980 +WC_PD_2004_CAPFT,,BiQuadratic,,,,0.906115,0.0292277,-0.0003647,-0.0009709,-9.05e-05,0.0002527,,,,,5,10,17.78,46.11,,,From PNNL Prototype Hospital +WC_PD_2010_PB_CAPFT,,BiQuadratic,,,,0.9061171,0.0292267,-0.0003665,-0.0009698,-9.07e-05,0.0002535,,,,,5,10,17.78,46.11,,,From PNNL Prototype OfficeLarge WC_PD_2010_PB_EIRFT,,BiQuadratic,,,,0.3617782,-0.0230016,0.0009672,0.0131801,0.0003761,-0.0007121,,,,,5,10,17.78,46.11,,,From PNNL Prototype OfficeLarge MT_compressor_power,Refrigeration,BiCubic,Power,Suction T,Discharge T,7438.92229,-269.59756,-9.8561045,553.57326,-3.3858896,14.8657878,-0.1007963,0.00982279,0.09736236,-0.039675217,-23.3,7.2,10,60,,,From AEDG MT_compressor_capacity,Refrigeration,BiCubic,Capacity,Suction T,Discharge T,151166.436,5266.34789,60.6727151,-1851.5594,5.73132755,-46.927717,0.1364012,-0.0356979,-0.403054,-0.039290478,-23.3,-7.2,10,60,,,From AEDG @@ -725,10 +725,10 @@ MT_compressor_capacity_smallandold,Refrigeration,BiCubic,Capacity,Suction T,Disc MT_compressor_power_smallandold,Refrigeration,BiCubic,Power,Suction T,Discharge T,483.6,-53.2,-1.384,56.19,0.003688,1.439,-0.008268,-0.00281,0.007222,0.006025,-17.8,4.4,10,48.9,,,From EP DataSets LT_compressor_capacity_smallandold,Refrigeration,BiCubic,Capacity,Suction T,Discharge T,23500,816.7,10.7,-28.24,0.1131,-0.4553,0.05604,-0.00412,-0.006728,0.006782,-40,-17.8,10,48.9,,,From EP DataSets LT_compressor_power_smallandold,Refrigeration,BiCubic,Power,Suction T,Discharge T,4018,95,1.507,5.705,1.247,-1.381,0.01277,-0.007518,-0.02424,0.02917,-40,-17.8,10,48.9,,,From EP DataSets -Glass Door Latent Curve Case,Refrigeration,Cubic,,,,0.3379,0.0309,0.0005,0.00004,,,,,,,-55,55,,,,,From AEDG -Coffin Latent Curve Case,Refrigeration,Cubic,,,,0.3379,0.0309,0.0005,0.00004,,,,,,,-55,55,,,,,From AEDG -Open Latent Curve Case,Refrigeration,Cubic,,,,-0.0187,0.0458,0.0011,0.00005,,,,,,,-55,55,,,,,From AEDG -Glass Door Defrost Curve Walkin,Refrigeration,Cubic,,,,0.3475,0.0296,0.0007,0.00003,,,,,,,-55,55,,,,,From AEDG -Coffin Defrost Curve Walkin,Refrigeration,Cubic,,,,0.3475,0.0296,0.0007,0.00003,,,,,,,-55,55,,,,,From AEDG -Open Defrost Curve Walkin,Refrigeration,Cubic,,,,0.0572,0.0461,0.0004,0.00006,,,,,,,-55,55,,,,,From AEDG -Refrigeration Case Latent Credit Curve,Refrigeration,Cubic,,,,0.026526281,0.001078032,6.02558E-05,1.23732E-06,,,,,,,-35,20,,,,, +Glass Door Latent Curve Case,Refrigeration,Cubic,,,,0.3379,0.0309,0.0005,4e-05,,,,,,,-55,55,,,,,From AEDG +Coffin Latent Curve Case,Refrigeration,Cubic,,,,0.3379,0.0309,0.0005,4e-05,,,,,,,-55,55,,,,,From AEDG +Open Latent Curve Case,Refrigeration,Cubic,,,,-0.0187,0.0458,0.0011,5e-05,,,,,,,-55,55,,,,,From AEDG +Glass Door Defrost Curve Walkin,Refrigeration,Cubic,,,,0.3475,0.0296,0.0007,3e-05,,,,,,,-55,55,,,,,From AEDG +Coffin Defrost Curve Walkin,Refrigeration,Cubic,,,,0.3475,0.0296,0.0007,3e-05,,,,,,,-55,55,,,,,From AEDG +Open Defrost Curve Walkin,Refrigeration,Cubic,,,,0.0572,0.0461,0.0004,6e-05,,,,,,,-55,55,,,,,From AEDG +Refrigeration Case Latent Credit Curve,Refrigeration,Cubic,,,,0.026526281,0.001078032,6.02558e-05,1.23732e-06,,,,,,,-35,20,,,,, diff --git a/data/openstudio_standards_data/database_files/support_performance_curves.json b/data/openstudio_standards_data/database_files/support_performance_curves.json new file mode 100644 index 0000000000..eadb697a54 --- /dev/null +++ b/data/openstudio_standards_data/database_files/support_performance_curves.json @@ -0,0 +1,18327 @@ +[ + { + "name": "a-Si_Spectral-fAirMass", + "category": "PV-Module", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": "AirMass", + "independent_variable_2": null, + "coeff_1": 0.99264449, + "coeff_2": 0.05334853, + "coeff_3": -0.0372019, + "coeff_4": 0.00327026, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Absor-1-Cap-fCHWT&ECT", + "category": "1-StageAbsorptn", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 1.757428, + "coeff_2": 0.054774, + "coeff_3": -0.00290628, + "coeff_4": -0.035145, + "coeff_5": -0.000156, + "coeff_6": 0.000894, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44444, + "maximum_independent_variable_1": 18.33333, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Absor-1-HIR-fCHWT&ECT", + "category": "1-StageAbsorptn", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 0.691153, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0.005355, + "coeff_5": 0.000178, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44444, + "maximum_independent_variable_1": 18.33333, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Absor-1-HIR-fPLR", + "category": "1-StageAbsorptn", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.087773, + "coeff_2": 0.744921, + "coeff_3": 0.167306, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Absor-2-Cap-fCHWT&ECT", + "category": "2-StageAbsorptn", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 0.362073, + "coeff_2": 0.0001386, + "coeff_3": 0.001458, + "coeff_4": 0.0733878, + "coeff_5": -0.00206064, + "coeff_6": 0.00101, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44444, + "maximum_independent_variable_1": 18.33333, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Absor-2-HIR-fCHWT&ECT", + "category": "2-StageAbsorptn", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 0.98675, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": -0.0234, + "coeff_5": 0.00081, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44444, + "maximum_independent_variable_1": 18.33333, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Absor-2-HIR-fPLR", + "category": "2-StageAbsorptn", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.1355115, + "coeff_2": 0.61798084, + "coeff_3": 0.24651277, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "AHU-1_CoolCStandard10Ton_CapFF", + "category": "DX Cooling Coil", + "form": "Quadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.77136, + "coeff_2": 0.34053, + "coeff_3": -0.11088, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.75918, + "maximum_independent_variable_1": 1.13877, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" + }, + { + "name": "AirCooled_Chiller_2004_CAPFT", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 1.0433811, + "coeff_2": 0.0407077, + "coeff_3": 0.0004506, + "coeff_4": -0.0041514, + "coeff_5": -8.86e-05, + "coeff_6": -0.0003467, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 12.7, + "maximum_independent_variable_2": 51.67, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "AirCooled_Chiller_2004_EIRFT", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.5961915, + "coeff_2": -0.0099496, + "coeff_3": 0.0007888, + "coeff_4": 0.0004506, + "coeff_5": 0.0004875, + "coeff_6": -0.0007623, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 12.7, + "maximum_independent_variable_2": 51.67, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "AirCooled_Chiller_2010_PathA_CAPFT", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 1.0433825, + "coeff_2": 0.0407073, + "coeff_3": 0.0004506, + "coeff_4": -0.0041514, + "coeff_5": -8.86e-05, + "coeff_6": -0.0003467, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 12.7, + "maximum_independent_variable_2": 51.67, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "AirCooled_Chiller_2010_PathA_EIRFT", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.5961915, + "coeff_2": -0.0099496, + "coeff_3": 0.0007888, + "coeff_4": 0.0004506, + "coeff_5": 0.0004875, + "coeff_6": -0.0007623, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 12.7, + "maximum_independent_variable_2": 51.67, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR", + "category": "Electric Chiller", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.141, + "coeff_2": 0.655, + "coeff_3": 0.203, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010. EIRFPLR curve is identical for all AirCooled Chillers" + }, + { + "name": "AirCooled_Chiller_GT150_2004_EIRFPLR", + "category": "Electric Chiller", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.141, + "coeff_2": 0.655, + "coeff_3": 0.203, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "AirCooled_Chiller_GT150_2010_PathA_EIRFPLR", + "category": "Electric Chiller", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.141, + "coeff_2": 0.655, + "coeff_3": 0.203, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "AirCooled_Chiller_LT150_2004_EIRFPLR", + "category": "Electric Chiller", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.141, + "coeff_2": 0.655, + "coeff_3": 0.203, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "AirCooled_Chiller_LT150_2010_PathA_EIRFPLR", + "category": "Electric Chiller", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.141, + "coeff_2": 0.655, + "coeff_3": 0.203, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "AirFoil w Dischrg Dampers FPLR", + "category": "FanEIR-FPLR", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.227143, + "coeff_2": 1.178929, + "coeff_3": -0.410714, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.68, + "maximum_dependent_variable_output": 1, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "AirFoil w Inlet Vanes FPLR", + "category": "FanEIR-FPLR", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.584345, + "coeff_2": -0.579167, + "coeff_3": 0.970238, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.48, + "maximum_dependent_variable_output": 1, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Atmospheric-Blr-HIR-fPLR", + "category": "FuelBoilers", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.02699999, + "coeff_2": 1.10549998, + "coeff_3": -0.13249961, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Boiler Constant Efficiency Curve", + "category": "Boiler", + "form": "Cubic", + "dependent_variable": "FIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From DOE Reference Building" + }, + { + "name": "Boiler with Minimum Turndown", + "category": "Boiler", + "form": "Cubic", + "dependent_variable": "FIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.7791, + "coeff_2": 1.4745, + "coeff_3": -2.5795, + "coeff_4": 1.3467, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.3, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Regression of Prototype Building EMS" + }, + { + "name": "Boiler with No Minimum Turndown", + "category": "Boiler", + "form": "Cubic", + "dependent_variable": "FIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.7463, + "coeff_2": 1.3196, + "coeff_3": -2.2154, + "coeff_4": 1.1674, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.3, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Regression of Prototype Building EMS" + }, + { + "name": "BOILER-EFFFPLR-NECB2011", + "category": "Boiler", + "form": "Cubic", + "dependent_variable": "FIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.2901, + "coeff_2": 2.6664, + "coeff_3": -3.764, + "coeff_4": 1.82, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From NECB 2011" + }, + { + "name": "CdTe_Spectral-fAirMass", + "category": "PV-Module", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": "AirMass", + "independent_variable_2": null, + "coeff_1": 0.93700588, + "coeff_2": 0.05130703, + "coeff_3": -0.00646639, + "coeff_4": 0.00017267, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "CentChlrAirCoolCap-fCHW&OAT", + "category": "Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "OAT", + "coeff_1": 0.94533053, + "coeff_2": 0.068473818, + "coeff_3": -0.003361694, + "coeff_4": 0.000108108, + "coeff_5": -0.000225, + "coeff_6": 8.2e-05, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "CentChlrAirCoolEIR-fCHW&OAT", + "category": "Chiller", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "OAT", + "coeff_1": 0.47343824, + "coeff_2": 0.015708042, + "coeff_3": -0.000948, + "coeff_4": 0.012260718, + "coeff_5": 9.55e-05, + "coeff_6": -0.000352, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "CentChlrAirCoolEIR-fPLR", + "category": "Chiller", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.24258, + "coeff_2": 0.41468, + "coeff_3": 0.34273973, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "CentH2O-Cap-fCHWT&ECT", + "category": "HermCentrifugal", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 0.36460761, + "coeff_2": -0.030523554, + "coeff_3": -0.001929776, + "coeff_4": 0.066367926, + "coeff_5": -0.001891966, + "coeff_6": 0.003110627, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "CentH2O-EIR-fCHWT&ECT", + "category": "HermCentrifugal", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 0.65868459, + "coeff_2": -0.025336458, + "coeff_3": 0.000991, + "coeff_4": 0.01280322, + "coeff_5": 0.000171, + "coeff_6": -0.000301, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "CentH2O-EIR-fPLR&dT", + "category": "HermCentrifugal", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": "dT", + "coeff_1": 0.27969646, + "coeff_2": 0.57375735, + "coeff_3": 0.25690463, + "coeff_4": -0.010452906, + "coeff_5": 0.000475, + "coeff_6": -0.006354126, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "CentH2OVSD-Cap-fCHWT&ECT", + "category": "HermCentrifugal", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 0.36211013, + "coeff_2": -0.032249754, + "coeff_3": -0.000886, + "coeff_4": 0.066743838, + "coeff_5": -0.001731488, + "coeff_6": 0.002180358, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "CentH2OVSD-EIR-fCHWT&ECT", + "category": "HermCentrifugal", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 0.41386133, + "coeff_2": -0.088037676, + "coeff_3": 0.00098, + "coeff_4": 0.056770308, + "coeff_5": -0.000946, + "coeff_6": 0.001418731, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "CentH2OVSD-EIR-fPLR&dT", + "category": "HermCentrifugal", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": "dT", + "coeff_1": 0.14703037, + "coeff_2": -0.00349667, + "coeff_3": 1.01161313, + "coeff_4": -0.006474546, + "coeff_5": 0.00088, + "coeff_6": -0.020960478, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ChillerCentCapFT", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.7446451, + "coeff_2": 0.0114858, + "coeff_3": 1.48e-05, + "coeff_4": 0.022401, + "coeff_5": -0.000688, + "coeff_6": 0.0009839, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 24, + "maximum_independent_variable_2": 35, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Dick Lord's Chiller Model study for ASHRAE 2007 baseline" + }, + { + "name": "ChillerCentEIRFT", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.772877, + "coeff_2": 0.022101, + "coeff_3": -7.99e-05, + "coeff_4": -0.0070045, + "coeff_5": 0.0004763, + "coeff_6": -0.0010612, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 24, + "maximum_independent_variable_2": 35, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Dick Lord's Chiller Model study for ASHRAE 2007 baseline" + }, + { + "name": "ChillerCentEIRPLR", + "category": "Electric Chiller", + "form": "BiCubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tcws", + "independent_variable_2": "QRatio", + "coeff_1": -0.1360532, + "coeff_2": 0.008642703, + "coeff_3": 3.85558e-06, + "coeff_4": 1.024034, + "coeff_5": 0.06047444, + "coeff_6": -0.00894786, + "coeff_7": 0, + "coeff_8": 0.05706602, + "coeff_9": 0, + "coeff_10": 0, + "minimum_independent_variable_1": 31.13, + "maximum_independent_variable_1": 36.52, + "minimum_independent_variable_2": 0.19, + "maximum_independent_variable_2": 1.03, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Dick Lord's Chiller Model study for ASHRAE 2007 baseline" + }, + { + "name": "ChlrAirRecipEIRRatio_fQRatio", + "category": "Electric Chiller", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.114437, + "coeff_2": 0.545933, + "coeff_3": 0.342299, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.11, + "maximum_dependent_variable_output": null, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "ChlrAirRecipEIRRatio_fTchwsToadbSI", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.542784, + "coeff_2": -0.013907, + "coeff_3": 0.000476, + "coeff_4": 0.012197, + "coeff_5": 0.000149, + "coeff_6": -0.000334, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44, + "maximum_independent_variable_1": 12.22, + "minimum_independent_variable_2": 23.89, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": 0.72, + "maximum_dependent_variable_output": 1.3, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "ChlrAirRecipQRatio_fTchwsToadbSI", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 1.12603, + "coeff_2": 0.041571, + "coeff_3": 0.000253, + "coeff_4": -0.010526, + "coeff_5": 1e-05, + "coeff_6": -0.000256, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44, + "maximum_independent_variable_1": 12.22, + "minimum_independent_variable_2": 23.89, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": 0.82, + "maximum_dependent_variable_output": 1.3, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "ChlrAirScrewEIRRatio_fQRatio", + "category": "Electric Chiller", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.036487, + "coeff_2": 0.734743, + "coeff_3": 0.219947, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.04, + "maximum_dependent_variable_output": null, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "ChlrAirScrewEIRRatio_fTchwsToadbSI", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.570624, + "coeff_2": 0.011954, + "coeff_3": -0.000522, + "coeff_4": -3.2e-05, + "coeff_5": 0.000421, + "coeff_6": -0.000606, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44, + "maximum_independent_variable_1": 12.22, + "minimum_independent_variable_2": 23.89, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": 0.7, + "maximum_dependent_variable_output": 1.38, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "ChlrAirScrewQRatio_fTchwsToadbSI", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.985959, + "coeff_2": 0.049487, + "coeff_3": -0.000298, + "coeff_4": -0.003737, + "coeff_5": -4.5e-05, + "coeff_6": -0.000502, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44, + "maximum_independent_variable_1": 12.22, + "minimum_independent_variable_2": 23.89, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": 0.82, + "maximum_dependent_variable_output": 1.3, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "ChlrAirScrollEIRRatio_fQRatio", + "category": "Electric Chiller", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.063691, + "coeff_2": 0.584888, + "coeff_3": 0.352803, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.06, + "maximum_dependent_variable_output": null, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "ChlrAirScrollEIRRatio_fTchwsToadbSI", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.702194, + "coeff_2": -0.004466, + "coeff_3": 0.000535, + "coeff_4": -0.005506, + "coeff_5": 0.000544, + "coeff_6": -0.000729, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44, + "maximum_independent_variable_1": 12.22, + "minimum_independent_variable_2": 23.89, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": 0.69, + "maximum_dependent_variable_output": 1.45, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "ChlrAirScrollQRatio_fTchwsToadbSI", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 1.02138, + "coeff_2": 0.037021, + "coeff_3": 0.000233, + "coeff_4": -0.003893, + "coeff_5": -6.5e-05, + "coeff_6": -0.000269, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44, + "maximum_independent_variable_1": 12.22, + "minimum_independent_variable_2": 23.89, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": 0.82, + "maximum_dependent_variable_output": 1.3, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "ChlrHPAirCoolCap-fCHW&OAT", + "category": "Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "OAT", + "coeff_1": 1.13076899, + "coeff_2": 0.03157983, + "coeff_3": 0.000358, + "coeff_4": -0.009856332, + "coeff_5": 1.01e-05, + "coeff_6": -0.00015, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ChlrHPAirCoolEIR-fCHW&OAT", + "category": "Chiller", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "OAT", + "coeff_1": 0.5637406, + "coeff_2": -0.009225918, + "coeff_3": 0.000353, + "coeff_4": 0.009452178, + "coeff_5": 0.000187, + "coeff_6": -0.000314, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ChlrHPAirHeatCap-fHW&39-", + "category": "Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "HW", + "independent_variable_2": "39", + "coeff_1": 0.92141508, + "coeff_2": -0.003413682, + "coeff_3": -3.86e-06, + "coeff_4": 0.0324, + "coeff_5": 0.000611, + "coeff_6": -5.18e-05, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ChlrHPAirHeatCap-fHW&39+", + "category": "Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "HW", + "independent_variable_2": "39+", + "coeff_1": 0.94069023, + "coeff_2": -0.004035888, + "coeff_3": 4.21e-07, + "coeff_4": 0.046218906, + "coeff_5": -0.001703171, + "coeff_6": -2.27e-07, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ChlrHPAirHeatEIR-fHW&39-", + "category": "Chiller", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "HW", + "independent_variable_2": "39", + "coeff_1": 0.33398382, + "coeff_2": 0.019817694, + "coeff_3": 1.2e-05, + "coeff_4": 0.0048024, + "coeff_5": -3.32e-05, + "coeff_6": -0.000898, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ChlrHPAirHeatEIR-fHW&39+", + "category": "Chiller", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "HW", + "independent_variable_2": "39+", + "coeff_1": 0.38886863, + "coeff_2": 0.018107262, + "coeff_3": 1.94e-05, + "coeff_4": -0.026683668, + "coeff_5": 0.002056655, + "coeff_6": -0.000499, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ChlrHPH2OCoolCap_fCHW&ECT", + "category": "Chiller/HP", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 35.68362061, + "coeff_2": 0.62273101, + "coeff_3": -0.005677932, + "coeff_4": -0.248948775, + "coeff_5": -0.003461286, + "coeff_6": 0.011142622, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ChlrHPH2OCoolCap_fCHW&ECT-Old", + "category": "Chiller/HP", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 0.96601399, + "coeff_2": 0.04050054, + "coeff_3": 0.000589, + "coeff_4": -0.008098668, + "coeff_5": 6.65e-05, + "coeff_6": -0.000454, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ChlrHPH2OCoolEIR_fCHW&ECT", + "category": "Chiller/HP", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 0.111287472, + "coeff_2": -0.002094557, + "coeff_3": 0.000201, + "coeff_4": 0.00170532, + "coeff_5": 0.000168, + "coeff_6": -0.000308, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ChlrHPH2OCoolEIR_fCHW&ECT-Old", + "category": "Chiller/HP", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 0.61092869, + "coeff_2": -0.016352352, + "coeff_3": 0.000407, + "coeff_4": 0.003044232, + "coeff_5": 0.000592, + "coeff_6": -0.000668, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ChlrHPH2OHeatCap_fHWS&EET", + "category": "Chiller/HP", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "HWS", + "independent_variable_2": "EET", + "coeff_1": 29.914016, + "coeff_2": 0.1544256, + "coeff_3": -0.0041472, + "coeff_4": 0.6832512, + "coeff_5": -0.00203148, + "coeff_6": 0.00199584, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ChlrHPH2OHeatCap_fHWS&EET-Old", + "category": "Chiller/HP", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "HWS", + "independent_variable_2": "EET", + "coeff_1": 0.84649612, + "coeff_2": -0.00264807, + "coeff_3": 2.31e-05, + "coeff_4": 0.02700126, + "coeff_5": 0.00013, + "coeff_6": -0.000127, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ChlrHPH2OHeatEIR_fHWS&EET", + "category": "Chiller/HP", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "HWS", + "independent_variable_2": "EET", + "coeff_1": 0.12004, + "coeff_2": -0.00011232, + "coeff_3": 9.85e-05, + "coeff_4": -0.00107928, + "coeff_5": 7.32e-05, + "coeff_6": -0.000134, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ChlrHPH2OHeatEIR_fHWS&EET-Old", + "category": "Chiller/HP", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "HWS", + "independent_variable_2": "EET", + "coeff_1": 0.2068226, + "coeff_2": 0.018812142, + "coeff_3": 0.000105, + "coeff_4": -0.012659724, + "coeff_5": 0.000406, + "coeff_6": -0.000399, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ChlrWtrCentPathAAllEIRRatio_fQRatio", + "category": "Electric Chiller", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.222149, + "coeff_2": 0.503156, + "coeff_3": 0.256905, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.1, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.28, + "maximum_dependent_variable_output": null, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "ChlrWtrCentPathAAllEIRRatio_fTchwsTcwsSI", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Tcws", + "coeff_1": 0.658643, + "coeff_2": -0.025339, + "coeff_3": 0.000991, + "coeff_4": 0.012801, + "coeff_5": 0.000171, + "coeff_6": -0.000301, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44, + "maximum_independent_variable_1": 12.22, + "minimum_independent_variable_2": 15.56, + "maximum_independent_variable_2": 29.44, + "minimum_dependent_variable_output": 0.68, + "maximum_dependent_variable_output": 1.05, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "ChlrWtrCentPathAAllQRatio_fTchwsTcwsSI", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Tcws", + "coeff_1": 0.364691, + "coeff_2": -0.030521, + "coeff_3": -0.00193, + "coeff_4": 0.066374, + "coeff_5": -0.001892, + "coeff_6": 0.003111, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44, + "maximum_independent_variable_1": 12.22, + "minimum_independent_variable_2": 15.56, + "maximum_independent_variable_2": 29.44, + "minimum_dependent_variable_output": 0.87, + "maximum_dependent_variable_output": 0.91, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "ChlrWtrCentPathBGtEql300Lt600tonEIRRatio_fQRatio", + "category": "Electric Chiller", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.055483, + "coeff_2": 0.451866, + "coeff_3": 0.488242, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.1, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.11, + "maximum_dependent_variable_output": null, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "ChlrWtrCentPathBGtEql300Lt600tonEIRRatio_fTchwsTcwsSI", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Tcws", + "coeff_1": 0.756376, + "coeff_2": -0.015019, + "coeff_3": 0.000156, + "coeff_4": 0.00246, + "coeff_5": 0.000515, + "coeff_6": -0.000687, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44, + "maximum_independent_variable_1": 12.22, + "minimum_independent_variable_2": 15.56, + "maximum_independent_variable_2": 29.44, + "minimum_dependent_variable_output": 0.63, + "maximum_dependent_variable_output": 1.12, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "ChlrWtrCentPathBGtEql300Lt600tonQRatio_fTchwsTcwsSI", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Tcws", + "coeff_1": 1.35608, + "coeff_2": 0.04875, + "coeff_3": -0.000888, + "coeff_4": -0.014525, + "coeff_5": -0.000286, + "coeff_6": -4e-05, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44, + "maximum_independent_variable_1": 12.22, + "minimum_independent_variable_2": 15.56, + "maximum_independent_variable_2": 29.44, + "minimum_dependent_variable_output": 0.87, + "maximum_dependent_variable_output": 1.52, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "ChlrWtrCentPathBGtEql600tonEIRRatio_fQRatio", + "category": "Electric Chiller", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.107426, + "coeff_2": 0.156775, + "coeff_3": 0.739345, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.1, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.13, + "maximum_dependent_variable_output": null, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "ChlrWtrCentPathBGtEql600tonEIRRatio_fTchwsTcwsSI", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Tcws", + "coeff_1": 0.737625, + "coeff_2": 0.001456, + "coeff_3": -0.000223, + "coeff_4": 0.007116, + "coeff_5": 0.000267, + "coeff_6": -0.000735, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44, + "maximum_independent_variable_1": 12.22, + "minimum_independent_variable_2": 15.56, + "maximum_independent_variable_2": 29.44, + "minimum_dependent_variable_output": 0.76, + "maximum_dependent_variable_output": 1.08, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "ChlrWtrCentPathBGtEql600tonQRatio_fTchwsTcwsSI", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Tcws", + "coeff_1": 0.854454, + "coeff_2": 0.042526, + "coeff_3": -0.000185, + "coeff_4": 0.011697, + "coeff_5": -0.000497, + "coeff_6": -0.000412, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44, + "maximum_independent_variable_1": 12.22, + "minimum_independent_variable_2": 15.56, + "maximum_independent_variable_2": 29.44, + "minimum_dependent_variable_output": 0.9, + "maximum_dependent_variable_output": 1.33, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "ChlrWtrCentPathBLt300tonEIRRatio_fQRatio", + "category": "Electric Chiller", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.208389, + "coeff_2": -0.121404, + "coeff_3": 0.918455, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.1, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.21, + "maximum_dependent_variable_output": null, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "ChlrWtrCentPathBLt300tonEIRRatio_fTchwsTcwsSI", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Tcws", + "coeff_1": 0.711108, + "coeff_2": -0.023515, + "coeff_3": 0.001194, + "coeff_4": 0.017737, + "coeff_5": 0.000152, + "coeff_6": -0.001159, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44, + "maximum_independent_variable_1": 12.22, + "minimum_independent_variable_2": 15.56, + "maximum_independent_variable_2": 29.44, + "minimum_dependent_variable_output": 0.69, + "maximum_dependent_variable_output": 1.13, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "ChlrWtrCentPathBLt300tonQRatio_fTchwsTcwsSI", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Tcws", + "coeff_1": 1.15508, + "coeff_2": 0.036503, + "coeff_3": -0.000499, + "coeff_4": -0.001455, + "coeff_5": -0.000439, + "coeff_6": -0.000172, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44, + "maximum_independent_variable_1": 12.22, + "minimum_independent_variable_2": 15.56, + "maximum_independent_variable_2": 29.44, + "minimum_dependent_variable_output": 0.86, + "maximum_dependent_variable_output": 1.37, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "ChlrWtrPosDispPathAAllEIRRatio_fQRatio", + "category": "Electric Chiller", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.310965, + "coeff_2": 0.322519, + "coeff_3": 0.372745, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.1, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.35, + "maximum_dependent_variable_output": null, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Tcws", + "coeff_1": 0.665307, + "coeff_2": -0.009339, + "coeff_3": 0.000483, + "coeff_4": 0.009492, + "coeff_5": 0.000544, + "coeff_6": -0.000864, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44, + "maximum_independent_variable_1": 12.22, + "minimum_independent_variable_2": 15.56, + "maximum_independent_variable_2": 29.44, + "minimum_dependent_variable_output": 0.74, + "maximum_dependent_variable_output": 1.27, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Tcws", + "coeff_1": 0.96744, + "coeff_2": 0.037082, + "coeff_3": 0.000434, + "coeff_4": -0.005837, + "coeff_5": -4.9e-05, + "coeff_6": -0.000274, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44, + "maximum_independent_variable_1": 12.22, + "minimum_independent_variable_2": 15.56, + "maximum_independent_variable_2": 29.44, + "minimum_dependent_variable_output": 0.89, + "maximum_dependent_variable_output": 1.33, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "ChlrWtrPosDispPathBAllEIRRatio_fQRatio", + "category": "Electric Chiller", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0, + "coeff_2": 0.6206, + "coeff_3": 0.3893, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.1, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.07, + "maximum_dependent_variable_output": null, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "ChlrWtrPosDispPathBAllEIRRatio_fTchwsTcwsSI", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Tcws", + "coeff_1": 0.428265, + "coeff_2": -0.024071, + "coeff_3": 0.000849, + "coeff_4": 0.016416, + "coeff_5": 0.000381, + "coeff_6": -0.00059, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44, + "maximum_independent_variable_1": 12.22, + "minimum_independent_variable_2": 15.56, + "maximum_independent_variable_2": 29.44, + "minimum_dependent_variable_output": 0.5, + "maximum_dependent_variable_output": 1.07, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "ChlrWtrPosDispPathBAllQRatio_fTchwsTcwsSI", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Tcws", + "coeff_1": 0.899926, + "coeff_2": 0.030102, + "coeff_3": -0.000332, + "coeff_4": -0.001743, + "coeff_5": -9.2e-05, + "coeff_6": 0.000229, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44, + "maximum_independent_variable_1": 12.22, + "minimum_independent_variable_2": 15.56, + "maximum_independent_variable_2": 29.44, + "minimum_dependent_variable_output": 0.93, + "maximum_dependent_variable_output": 1.21, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "CHW-Coil-Cap-fAirflow", + "category": "CHWCoils", + "form": "Quadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Airflow", + "independent_variable_2": null, + "coeff_1": 0.0488, + "coeff_2": 1.38, + "coeff_3": -0.425, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "CHW-Coil-Cap-fEWB&EWT", + "category": "CHWCoils", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "EWT", + "coeff_1": 1.6726784, + "coeff_2": -0.13378464, + "coeff_3": 0.0065124, + "coeff_4": 0.03828096, + "coeff_5": 8.26e-05, + "coeff_6": -0.005868936, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 15.55556, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 4.44444, + "maximum_independent_variable_2": 18.33333, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "CHW-Coil-Cap-fFluidFlow", + "category": "CHWCoils", + "form": "Quadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "FluidFlow", + "independent_variable_2": null, + "coeff_1": 0.218, + "coeff_2": 3199.5088, + "coeff_3": -3280000, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Coffin Defrost Curve", + "category": "Refrigerated Case", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.3475, + "coeff_2": 0.0296, + "coeff_3": 0.0007, + "coeff_4": 3e-05, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -55, + "maximum_independent_variable_1": 55, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "For SuperMarket Prototype Buildings" + }, + { + "name": "Coffin Latent Curve", + "category": "Refrigerated Case", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.3379, + "coeff_2": 0.0309, + "coeff_3": 0.0005, + "coeff_4": 4e-05, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -55, + "maximum_independent_variable_1": 55, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "For SuperMarket Prototype Buildings" + }, + { + "name": "COIL-BF-FFLOW-SPEC", + "category": "CoilBF-FFLOW", + "form": "Linear", + "dependent_variable": null, + "independent_variable_1": "Flow", + "independent_variable_2": null, + "coeff_1": 0.33, + "coeff_2": 1419.6496, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.8, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Coil-Bypass-Factor-fPLR", + "category": "CHWCoils", + "form": "Linear", + "dependent_variable": "QRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "CoilClgDXDblEIRRatio_fCFMRatio", + "category": "DX Cooling Coil", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 1.007948, + "coeff_2": 0.345441, + "coeff_3": -0.692289, + "coeff_4": 0.338899, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "CoilClgDXDblQRatio_fCFMRatio", + "category": "DX Cooling Coil", + "form": "Cubic", + "dependent_variable": "QRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.472786, + "coeff_2": 1.243342, + "coeff_3": -1.038706, + "coeff_4": 0.322578, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -100, + "maximum_independent_variable_1": 100, + "minimum_independent_variable_2": 0.47, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "CoilClgDXEIRRatio_fQFrac", + "category": "DX Cooling Coil", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0, + "coeff_2": 5.1091, + "coeff_3": -8.5515, + "coeff_4": 4.4744, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.7, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": 0.92, + "maximum_independent_variable_2": 1, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "CoilClgDXEIRRatio_fTwbToadbSI", + "category": "DX Cooling Coil", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Twb", + "independent_variable_2": "Toadb", + "coeff_1": 0.116709, + "coeff_2": 0.028458, + "coeff_3": -0.000411, + "coeff_4": 0.021422, + "coeff_5": 0.000162, + "coeff_6": -0.00068, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 13.89, + "maximum_independent_variable_1": 25, + "minimum_independent_variable_2": 23.89, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": 0.77, + "maximum_dependent_variable_output": 1.33, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "CoilClgDXQRatio_fTwbToadbSI", + "category": "DX Cooling Coil", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Twb", + "independent_variable_2": "Toadb", + "coeff_1": 0.86779, + "coeff_2": 0.014245, + "coeff_3": 0.000554, + "coeff_4": -0.007569, + "coeff_5": 3.2e-05, + "coeff_6": -0.000191, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 13.89, + "maximum_independent_variable_1": 25, + "minimum_independent_variable_2": 23.89, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": 0.77, + "maximum_dependent_variable_output": 1.29, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "CoilClgDXSEER13EER11EIRRatio_fTwbToadbSI", + "category": "DX Cooling Coil", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Twb", + "independent_variable_2": "Toadb", + "coeff_1": -0.199992, + "coeff_2": -0.035686, + "coeff_3": 0.000787, + "coeff_4": 0.074834, + "coeff_5": -0.000516, + "coeff_6": -0.000573, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 13.89, + "maximum_independent_variable_1": 25, + "minimum_independent_variable_2": 23.89, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": 0.55, + "maximum_dependent_variable_output": 1.44, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "CoilClgDXSEER15EER11EIRRatio_fTwbToadbSI", + "category": "DX Cooling Coil", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Twb", + "independent_variable_2": "Toadb", + "coeff_1": -1.790474, + "coeff_2": -0.028777, + "coeff_3": 0.000763, + "coeff_4": 0.153391, + "coeff_5": -0.001482, + "coeff_6": -0.000721, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 13.89, + "maximum_independent_variable_1": 25, + "minimum_independent_variable_2": 23.89, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": 0.35, + "maximum_dependent_variable_output": 1.42, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "CoilClgDXSEER16EER13EIRRatio_fTwbToadbSI", + "category": "DX Cooling Coil", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Twb", + "independent_variable_2": "Toadb", + "coeff_1": 0.686684, + "coeff_2": -0.035826, + "coeff_3": 0.000781, + "coeff_4": 0.025564, + "coeff_5": 0.000163, + "coeff_6": -0.000559, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 13.89, + "maximum_independent_variable_1": 25, + "minimum_independent_variable_2": 23.89, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": 0.65, + "maximum_dependent_variable_output": 1.51, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "CoilClgDXSEER17EER11EIRRatio_fTwbToadbSI", + "category": "DX Cooling Coil", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Twb", + "independent_variable_2": "Toadb", + "coeff_1": -3.060538, + "coeff_2": -0.023207, + "coeff_3": 0.000744, + "coeff_4": 0.216093, + "coeff_5": -0.002253, + "coeff_6": -0.000839, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 13.89, + "maximum_independent_variable_1": 25, + "minimum_independent_variable_2": 23.89, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": 0.2, + "maximum_dependent_variable_output": 1.4, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "CoilClgDXSEER18EER13EIRRatio_fTwbToadbSI", + "category": "DX Cooling Coil", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Twb", + "independent_variable_2": "Toadb", + "coeff_1": -1.247121, + "coeff_2": -0.027513, + "coeff_3": 0.000752, + "coeff_4": 0.121123, + "coeff_5": -0.001013, + "coeff_6": -0.000736, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 13.89, + "maximum_independent_variable_1": 25, + "minimum_independent_variable_2": 23.89, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": 0.41, + "maximum_dependent_variable_output": 1.48, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "CoilClgDXSEER20EER13EIRRatio_fTwbToadbSI", + "category": "DX Cooling Coil", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Twb", + "independent_variable_2": "Toadb", + "coeff_1": -2.72492, + "coeff_2": -0.02112, + "coeff_3": 0.00073, + "coeff_4": 0.194128, + "coeff_5": -0.001911, + "coeff_6": -0.000872, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 13.89, + "maximum_independent_variable_1": 25, + "minimum_independent_variable_2": 23.89, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": 0.23, + "maximum_dependent_variable_output": 1.45, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "CoilClgDXSEEREIRRatio_fQFrac", + "category": "DX Cooling Coil", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.7, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": 1, + "maximum_independent_variable_2": 1, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "CoilClgDXSnglEIRRatio_fCFMRatio", + "category": "DX Cooling Coil", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 1.156, + "coeff_2": -0.1816, + "coeff_3": 0.0256, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "CoilClgDXSnglQRatio_fCFMRatio", + "category": "DX Cooling Coil", + "form": "Quadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.8, + "coeff_2": 0.2, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.5, + "maximum_independent_variable_1": 1.5, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "CoilClgPTACEIRRatio_fQFrac", + "category": "DX Cooling Coil", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.85, + "coeff_2": 0.15, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.7, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": 0.96, + "maximum_independent_variable_2": 1, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "CoilClgPTACEIRRatio_fTwbToadbSI", + "category": "DX Cooling Coil", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Twb", + "independent_variable_2": "Toadb", + "coeff_1": 0.341434, + "coeff_2": 0.03481, + "coeff_3": -0.000625, + "coeff_4": 0.004941, + "coeff_5": 0.000437, + "coeff_6": -0.000729, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 13.89, + "maximum_independent_variable_1": 25, + "minimum_independent_variable_2": 23.89, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": 0.75, + "maximum_dependent_variable_output": 1.4, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "CoilClgPTACQRatio_fTwbToadbSI", + "category": "DX Cooling Coil", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Twb", + "independent_variable_2": "Toadb", + "coeff_1": 0.942879, + "coeff_2": 0.009538, + "coeff_3": 0.000684, + "coeff_4": -0.011002, + "coeff_5": 6e-06, + "coeff_6": -1e-05, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 13.89, + "maximum_independent_variable_1": 25, + "minimum_independent_variable_2": 23.89, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": 0.71, + "maximum_dependent_variable_output": 1.34, + "annotation": "From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx" + }, + { + "name": "ConstantCubic", + "category": null, + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -100, + "maximum_independent_variable_1": 100, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Reference Buildings" + }, + { + "name": "Cool-PLF-fPLR", + "category": "DX Cooling Coil", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.90949556, + "coeff_2": 0.09864773, + "coeff_3": -0.00819488, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From PNNL Prototype FullServiceRestaurant" + }, + { + "name": "CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF", + "category": "DX Cooling Coil", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 1.2055, + "coeff_2": -0.32953, + "coeff_3": 0.12308, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.75918, + "maximum_independent_variable_1": 1.13877, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" + }, + { + "name": "Curve_Biquadratic_CBES_01", + "category": null, + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.86779, + "coeff_2": 0.014245, + "coeff_3": 0.000554, + "coeff_4": -0.007569, + "coeff_5": 3.2e-05, + "coeff_6": -0.000191, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 100, + "minimum_independent_variable_2": 0, + "maximum_independent_variable_2": 100, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov" + }, + { + "name": "Curve_Biquadratic_CBES_02", + "category": null, + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": -0.199992, + "coeff_2": -0.035686, + "coeff_3": 0.000787, + "coeff_4": 0.074834, + "coeff_5": -0.000516, + "coeff_6": -0.000573, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 13.9, + "maximum_independent_variable_1": 25, + "minimum_independent_variable_2": 23.9, + "maximum_independent_variable_2": 43.3, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov" + }, + { + "name": "Curve_Biquadratic_CBES_03", + "category": null, + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.9425878, + "coeff_2": 0.00954335, + "coeff_3": 0.00068377, + "coeff_4": -0.0110427, + "coeff_5": 5.25e-06, + "coeff_6": -9.72e-06, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 17, + "maximum_independent_variable_1": 22, + "minimum_independent_variable_2": 13, + "maximum_independent_variable_2": 46, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov" + }, + { + "name": "Curve_Biquadratic_CBES_04", + "category": null, + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.3424144, + "coeff_2": 0.03488501, + "coeff_3": -0.0006237, + "coeff_4": 0.00497722, + "coeff_5": 0.00043795, + "coeff_6": -0.000728, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 17, + "maximum_independent_variable_1": 22, + "minimum_independent_variable_2": 13, + "maximum_independent_variable_2": 46, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov" + }, + { + "name": "Curve_Quadratic_CBES_01", + "category": "DX Cooling Coil", + "form": "Quadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.8, + "coeff_2": 0.2, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.5, + "maximum_independent_variable_1": 1.5, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov" + }, + { + "name": "Curve_Quadratic_CBES_02", + "category": "DX Cooling Coil", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 1.156, + "coeff_2": -0.1816, + "coeff_3": 0.0256, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.5, + "maximum_independent_variable_1": 1.5, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov" + }, + { + "name": "Curve_Quadratic_CBES_03", + "category": null, + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov" + }, + { + "name": "Curve_Quadratic_CBES_04", + "category": null, + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.8, + "coeff_2": 0.2, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.5, + "maximum_independent_variable_1": 1.5, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov" + }, + { + "name": "Curve_Quadratic_CBES_05", + "category": null, + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 1.1552, + "coeff_2": -0.1808, + "coeff_3": 0.0256, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.5, + "maximum_independent_variable_1": 1.5, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov" + }, + { + "name": "Curve_Quadratic_CBES_06", + "category": null, + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.85, + "coeff_2": 0.15, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov" + }, + { + "name": "DEER DHW HIR-FPLR Curve", + "category": "DEERDHWHIR-FPLR", + "form": "Linear", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0, + "coeff_2": 1, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DEER_defrost", + "category": "Refrigeration", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.023632, + "coeff_2": 0.0006232, + "coeff_3": 2.832e-05, + "coeff_4": 4.4035e-07, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -23, + "maximum_independent_variable_1": 7, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": null + }, + { + "name": "DEER_Heat_Rejections_LT", + "category": "Refrigeration", + "form": "Linear", + "dependent_variable": "Capacity", + "independent_variable_1": "DeltaT", + "independent_variable_2": null, + "coeff_1": 0, + "coeff_2": 16383.61446, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -100, + "maximum_independent_variable_1": 100, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From eQuest Grocery store model" + }, + { + "name": "DEER_Heat_Rejections_MT", + "category": "Refrigeration", + "form": "Linear", + "dependent_variable": "Capacity", + "independent_variable_1": "DeltaT", + "independent_variable_2": null, + "coeff_1": 0, + "coeff_2": 20626.34211, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -100, + "maximum_independent_variable_1": 100, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From eQuest Grocery store model" + }, + { + "name": "Default_Case_Latent_Cedit_Curve", + "category": "Refrigeration", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.026526281, + "coeff_2": 0.001078032, + "coeff_3": -6.02558e-05, + "coeff_4": 1.23732e-06, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -35, + "maximum_independent_variable_1": 20, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": null + }, + { + "name": "Defrost-ResisDem-Frac-fOWB&ODB", + "category": "DXCool/Heat", + "form": "BiLinear", + "dependent_variable": "QRatio", + "independent_variable_1": "OWB", + "independent_variable_2": "ODB", + "coeff_1": 0.0333, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -23.333, + "maximum_independent_variable_1": 29.444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 29.444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Defrost-ResisTime-Frac-fOWB&ODB", + "category": "DXCool/Heat", + "form": "BiLinear", + "dependent_variable": "QRatio", + "independent_variable_1": "OWB", + "independent_variable_2": "ODB", + "coeff_1": 0.0333, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -23.333, + "maximum_independent_variable_1": 29.444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 29.444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Defrost-ReversDem-Frac-fOWB&ODB", + "category": "DXCool/Heat", + "form": "BiLinear", + "dependent_variable": "QRatio", + "independent_variable_1": "OWB", + "independent_variable_2": "ODB", + "coeff_1": 0.0333, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -23.333, + "maximum_independent_variable_1": 29.444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 29.444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Defrost-ReversTime-Frac-fOWB&ODB", + "category": "DXCool/Heat", + "form": "BiLinear", + "dependent_variable": "QRatio", + "independent_variable_1": "OWB", + "independent_variable_2": "ODB", + "coeff_1": 0.0583, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -23.333, + "maximum_independent_variable_1": 29.444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 29.444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Desc-Gas-fT&W", + "category": "Desiccant", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "W", + "coeff_1": 18784.36736, + "coeff_2": -3209.524992, + "coeff_3": -11.8830564, + "coeff_4": 3874.59, + "coeff_5": -1.69627, + "coeff_6": -23.53176, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 46.11111, + "minimum_independent_variable_2": 0, + "maximum_independent_variable_2": 0.1, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Desc-HR8-fWB1&WB6", + "category": "Desiccant", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "WB1", + "independent_variable_2": "WB6", + "coeff_1": -0.27680768, + "coeff_2": 0.071770464, + "coeff_3": 0.000735, + "coeff_4": 0.145668672, + "coeff_5": 0.000591, + "coeff_6": -0.002648246, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 46.11111, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Desc-HR8PL-fWB1&WB6", + "category": "Desiccant", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "WB1", + "independent_variable_2": "WB6", + "coeff_1": -0.05234208, + "coeff_2": 0.076111488, + "coeff_3": 0.000502, + "coeff_4": 0.11464641, + "coeff_5": 0.001235315, + "coeff_6": -0.002453879, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 46.11111, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Desc-kW-fT&W", + "category": "Desiccant", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "W", + "coeff_1": 3.33024, + "coeff_2": -0.010674, + "coeff_3": 0, + "coeff_4": 0.00404, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 46.11111, + "minimum_independent_variable_2": 0, + "maximum_independent_variable_2": 0.1, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Desc-QREG-fWB1&WB6", + "category": "Desiccant", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "WB1", + "independent_variable_2": "WB6", + "coeff_1": 80.58068736, + "coeff_2": -0.627217344, + "coeff_3": 0.0170748, + "coeff_4": -2.186211312, + "coeff_5": 4.37e-05, + "coeff_6": 0.018960674, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 40.55556, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Desc-QREGPL-fWB1&WB6", + "category": "Desiccant", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "WB1", + "independent_variable_2": "WB6", + "coeff_1": 20.30901408, + "coeff_2": -0.159663744, + "coeff_3": 0.0046008, + "coeff_4": -0.586622934, + "coeff_5": -0.00024, + "coeff_6": 0.005206064, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 46.11111, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Desc-T-fT&W", + "category": "Desiccant", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "W", + "coeff_1": 31.53328, + "coeff_2": 1.0173168, + "coeff_3": -0.0033372, + "coeff_4": 0.295, + "coeff_5": -0.00017, + "coeff_6": -0.0015696, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 46.11111, + "minimum_independent_variable_2": 0, + "maximum_independent_variable_2": 0.1, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Desc-T8-fWB1&WB6", + "category": "Desiccant", + "form": "BiLinear", + "dependent_variable": null, + "independent_variable_1": "WB1", + "independent_variable_2": "WB6", + "coeff_1": 34.64, + "coeff_2": 1.6236, + "coeff_3": 0.2574, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 46.11111, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Desc-T8PL-fWB1&WB6", + "category": "Desiccant", + "form": "BiLinear", + "dependent_variable": null, + "independent_variable_1": "WB1", + "independent_variable_2": "WB6", + "coeff_1": 32.7692, + "coeff_2": 1.7496, + "coeff_3": 0.06588, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 46.11111, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Desc-W-fT&W", + "category": "Desiccant", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "W", + "coeff_1": 7.82704, + "coeff_2": 0.119376, + "coeff_3": 0.0144504, + "coeff_4": 0.0831, + "coeff_5": 0.000697, + "coeff_6": 0.002862, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 46.11111, + "minimum_independent_variable_2": 0, + "maximum_independent_variable_2": 0.1, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Direct-Effectiveness-fFlow", + "category": "EvapCooler", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "Flow", + "independent_variable_2": null, + "coeff_1": 1.18, + "coeff_2": -546.67104, + "coeff_3": 333000, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DOE Ref DX Clg Coil Cool-CAP-fFlow", + "category": "DX Cooling Coil", + "form": "Cubic", + "dependent_variable": "QRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -100, + "maximum_independent_variable_1": 100, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From DOE Pre-1980 Reference Building" + }, + { + "name": "DOE Ref DX Clg Coil Cool-Cap-fT", + "category": "DX Cooling Coil", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Twb", + "independent_variable_2": "Toadb", + "coeff_1": 0.9712123, + "coeff_2": -0.015275502, + "coeff_3": 0.001443452, + "coeff_4": -0.00039321, + "coeff_5": -6.8364e-06, + "coeff_6": -0.000290596, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -100, + "maximum_independent_variable_1": 100, + "minimum_independent_variable_2": -100, + "maximum_independent_variable_2": 100, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From DOE Pre-1980 Reference Building" + }, + { + "name": "DOE Ref DX Clg Coil Cool-EIR-fFlow", + "category": "DX Cooling Coil", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -100, + "maximum_independent_variable_1": 100, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From DOE Pre-1980 Reference Building" + }, + { + "name": "DOE Ref DX Clg Coil Cool-EIR-fT", + "category": "DX Cooling Coil", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Twb", + "independent_variable_2": "Toadb", + "coeff_1": 0.28687133, + "coeff_2": 0.023902164, + "coeff_3": -0.000810648, + "coeff_4": 0.013458546, + "coeff_5": 0.000338936, + "coeff_6": -0.000487004, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -100, + "maximum_independent_variable_1": 100, + "minimum_independent_variable_2": -100, + "maximum_independent_variable_2": 100, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From DOE Pre-1980 Reference Building" + }, + { + "name": "DOE Ref DX Clg Coil Cool-PLF-fPLR", + "category": "DX Cooling Coil", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.90949556, + "coeff_2": 0.09864773, + "coeff_3": -0.00819488, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": null + }, + { + "name": "Draft-Fan-EIR-fPLR", + "category": "FuelBoilers", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.35071223, + "coeff_2": 0.3080535, + "coeff_3": -0.5413736, + "coeff_4": 0.87198823, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DW-Elec-EIR-fPLR", + "category": "ElecDW-Heater", + "form": "Linear", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0, + "coeff_2": 1, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DW-Gas-HIR-fPLR", + "category": "GasDW-Heater", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.021826, + "coeff_2": 0.97763, + "coeff_3": 0.000543, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DW-Gas-Pilotless-HIR-fPLR", + "category": "GasDW-Heater", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0, + "coeff_2": 0.999457, + "coeff_3": 0.000543, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DW-HeatPump-Cap-fSupplyT&EDB", + "category": "HeatPumpDW-Heat", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "SupplyT", + "independent_variable_2": "EDB", + "coeff_1": 0.74922298, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0.028130328, + "coeff_5": 0.000236, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DW-HeatPump-EIR-fPLR", + "category": "HeatPumpDW-Heat", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.08565215, + "coeff_2": 0.93881371, + "coeff_3": -0.1834361, + "coeff_4": 0.15897022, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DW-HeatPump-EIR-fSupplyT&EDB", + "category": "HeatPumpDW-Heat", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "SupplyT", + "independent_variable_2": "EDB", + "coeff_1": 1.25311702, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": -0.033921486, + "coeff_5": 0.000426, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DX Coil Cap-FF", + "category": "DX Cooling Coil", + "form": "Quadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.8, + "coeff_2": 0.2, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.5, + "maximum_independent_variable_1": 1.5, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From PNNL Prototype Buildings ApartmentMidRise, HotelSmall, OfficeSmall, RetailStandAlone, RetailStripmall, SchoolPrimary, Warehouse" + }, + { + "name": "DX-Bypass-Factor-fAirflow", + "category": "DXCool/Heat", + "form": "Quadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Airflow", + "independent_variable_2": null, + "coeff_1": -0.2542341, + "coeff_2": 1.2182557, + "coeff_3": 0.03597841, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DX-Bypass-Factor-fEWB&EDB", + "category": "DXCool/Heat", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "EDB", + "coeff_1": 0.8463094, + "coeff_2": 0.014259096, + "coeff_3": 0.000184, + "coeff_4": -0.014791716, + "coeff_5": -5.48e-06, + "coeff_6": 0.000487, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DX-Bypass-Factor-fPLR", + "category": "DXCool/Heat", + "form": "Linear", + "dependent_variable": "QRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DX-Cap-fAirflow", + "category": "DXCool/Heat", + "form": "Cubic", + "dependent_variable": "QRatio", + "independent_variable_1": "Airflow", + "independent_variable_2": null, + "coeff_1": 0.06429396, + "coeff_2": 1.99755645, + "coeff_3": -1.44277024, + "coeff_4": 0.38091758, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DX-Cool-Cap-fEWB&OAT", + "category": "DXCool/Heat", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "OAT", + "coeff_1": 0.86791562, + "coeff_2": 0.014247648, + "coeff_3": 0.000554, + "coeff_4": -0.007558056, + "coeff_5": 3.3e-05, + "coeff_6": -0.000192, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 21.11111, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DX-Cool-Cap-fRPM&OAT", + "category": "DXCool/Heat", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "RPM", + "independent_variable_2": "OAT", + "coeff_1": 32, + "coeff_2": 9.549296596, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DX-Cool-CondFan-fPLR&OAT", + "category": "DXCool/Heat", + "form": "BiQuadratic", + "dependent_variable": "PwrRatio", + "independent_variable_1": "PLR", + "independent_variable_2": "OAT", + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DX-Cool-CycleLoss-fPLR", + "category": "DXCool/Heat", + "form": "Linear", + "dependent_variable": "QRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.7, + "coeff_2": 0.3, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DX-Cool-EIR-fEWB&OAT", + "category": "DXCool/Heat", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "OAT", + "coeff_1": 0.1210048, + "coeff_2": 0.0285336, + "coeff_3": -0.000411, + "coeff_4": 0.02134944, + "coeff_5": 0.000161, + "coeff_6": -0.00068, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 21.11111, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DX-Cool-EIR-fPLR", + "category": "DXCool/Heat", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.201, + "coeff_2": -0.0312, + "coeff_3": 1.95, + "coeff_4": -1.12, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DX-Cool-EIR-fRPM&OAT", + "category": "DXCool/Heat", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "RPM", + "independent_variable_2": "OAT", + "coeff_1": 32, + "coeff_2": 9.549296596, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DX-Cool-Waste-Heat-fEWB&OAT", + "category": "DXCool/Heat", + "form": "BiLinear", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "OAT", + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 21.11111, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DX-Cool-Waste-Heat-fRPM&OAT", + "category": "DXCool/Heat", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "RPM", + "independent_variable_2": "OAT", + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DX-Heat-Cap-fEDB&OAT", + "category": "DXCool/Heat", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EDB", + "independent_variable_2": "OAT", + "coeff_1": 0.7422592, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0.030682602, + "coeff_5": 3.23e-05, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -12.22222, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DX-Heat-Cap-fRPM&OAT", + "category": "DXCool/Heat", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "RPM", + "independent_variable_2": "OAT", + "coeff_1": 32, + "coeff_2": 9.549296596, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": -23.33333, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DX-Heat-CondFan-fPLR&OAT", + "category": "DXCool/Heat", + "form": "BiQuadratic", + "dependent_variable": "PwrRatio", + "independent_variable_1": "PLR", + "independent_variable_2": "OAT", + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": -23.33333, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DX-Heat-CycleLoss-fPLR", + "category": "DXCool/Heat", + "form": "Linear", + "dependent_variable": "QRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.75, + "coeff_2": 0.25, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DX-Heat-EIR-fEDB&OAT", + "category": "DXCool/Heat", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "EDB", + "independent_variable_2": "OAT", + "coeff_1": 1.25399584, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": -0.040063338, + "coeff_5": 0.0010877, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -12.22222, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DX-Heat-EIR-fPLR", + "category": "DXCool/Heat", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.0857, + "coeff_2": 0.939, + "coeff_3": -0.183, + "coeff_4": 0.159, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DX-Heat-EIR-fRPM&OAT", + "category": "DXCool/Heat", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "RPM", + "independent_variable_2": "OAT", + "coeff_1": 32, + "coeff_2": 9.549296596, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": -23.33333, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DX-Heat-Waste-Heat-fEDB&OAT", + "category": "DXCool/Heat", + "form": "BiLinear", + "dependent_variable": "QRatio", + "independent_variable_1": "EDB", + "independent_variable_2": "OAT", + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -12.22222, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DX-Heat-Waste-Heat-fRPM&OAT", + "category": "DXCool/Heat", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "RPM", + "independent_variable_2": "OAT", + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": -23.33333, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DX-Sens-Cap-fAirflow", + "category": "DXCool/Heat", + "form": "Cubic", + "dependent_variable": "QRatio", + "independent_variable_1": "Airflow", + "independent_variable_2": null, + "coeff_1": 0.34465606, + "coeff_2": 0.89289891, + "coeff_3": -0.3554498, + "coeff_4": 0.1178948, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DX-Sens-Cap-fEWB&OAT", + "category": "DXCool/Heat", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "OAT", + "coeff_1": 2.93224448, + "coeff_2": -0.09445968, + "coeff_3": 0.0002, + "coeff_4": -0.007176816, + "coeff_5": 1.03e-05, + "coeff_6": 0.000109, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 21.11111, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "DXCOOL-NECB2011-REF-CAPFFLOW", + "category": "DX Cooling Coil", + "form": "Quadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From NECB 2011" + }, + { + "name": "DXCOOL-NECB2011-REF-CAPFT", + "category": "DX Cooling Coil", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Twb", + "independent_variable_2": "Toadb", + "coeff_1": 0.867905, + "coeff_2": 0.0142459, + "coeff_3": 0.00055436, + "coeff_4": -0.0075575, + "coeff_5": 3.3e-05, + "coeff_6": -0.0001918, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 13, + "maximum_independent_variable_1": 24, + "minimum_independent_variable_2": 24, + "maximum_independent_variable_2": 46, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From NECB 2011" + }, + { + "name": "DXCOOL-NECB2011-REF-COOLEIRFFLOW", + "category": "DX Cooling Coil", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From NECB 2011" + }, + { + "name": "DXCOOL-NECB2011-REF-COOLEIRFT", + "category": "DX Cooling Coil", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Twb", + "independent_variable_2": "Toadb", + "coeff_1": 0.116936, + "coeff_2": 0.0284933, + "coeff_3": -0.0004112, + "coeff_4": 0.0214108, + "coeff_5": 0.00016103, + "coeff_6": -0.0006791, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 13, + "maximum_independent_variable_1": 24, + "minimum_independent_variable_2": 24, + "maximum_independent_variable_2": 46, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From NECB 2011" + }, + { + "name": "DXCOOL-NECB2011-REF-COOLPLFFPLR", + "category": "DX Cooling Coil", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.0277, + "coeff_2": 4.9151, + "coeff_3": -8.184, + "coeff_4": 4.2702, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.7, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From NECB, curve modified to take into account how PLF is used in E+, and PLF ranges (> 0.7)" + }, + { + "name": "DXHEAT-NECB2011-REF-CAPFFLOW", + "category": "DX Heating Coil", + "form": "Cubic", + "dependent_variable": "QRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.84, + "coeff_2": 0.16, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.5, + "maximum_independent_variable_1": 1.5, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From NECB 2011" + }, + { + "name": "DXHEAT-NECB2011-REF-CAPFT", + "category": "DX Heating Coil", + "form": "Cubic", + "dependent_variable": "QRatio", + "independent_variable_1": "Toadb", + "independent_variable_2": null, + "coeff_1": 0.729, + "coeff_2": 0.0319, + "coeff_3": 0.000136, + "coeff_4": -8.75e-06, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -20, + "maximum_independent_variable_1": 20, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From NECB 2011" + }, + { + "name": "DXHEAT-NECB2011-REF-EIRFFLOW", + "category": "DX Cooling Coil", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 1.3824, + "coeff_2": -0.4336, + "coeff_3": 0.0512, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From NECB 2011" + }, + { + "name": "DXHEAT-NECB2011-REF-EIRFT", + "category": "DX Heating Coil", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Toadb", + "independent_variable_2": null, + "coeff_1": 1.2183, + "coeff_2": -0.03612, + "coeff_3": 0.00142, + "coeff_4": -2.68e-05, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -20, + "maximum_independent_variable_1": 20, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From NECB 2011" + }, + { + "name": "DXHEAT-NECB2011-REF-PLFFPLR", + "category": "DX Heating Coil", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.3696, + "coeff_2": 2.3362, + "coeff_3": -2.9577, + "coeff_4": 1.2596, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.7, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From NECB 2011" + }, + { + "name": "Minisplit-Heat-Cap-fT", + "category": "DX Heating Coil", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tiadb", + "independent_variable_2": "Toadb", + "coeff_1": 1.14715889, + "coeff_2": -0.010386676, + "coeff_3": 0, + "coeff_4": 0.008653846, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -100, + "maximum_independent_variable_1": 100, + "minimum_independent_variable_2": -100, + "maximum_independent_variable_2": 100, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From OpenStudio-HPXML" + }, + { + "name": "Minisplit-Heat-Cap-fFF", + "category": "DX Heating Coil", + "form": "Quadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tiadb", + "independent_variable_2": "Toadb", + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 2, + "minimum_independent_variable_2": 0, + "maximum_independent_variable_2": 2, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From OpenStudio-HPXML" + }, + { + "name": "Minisplit-Heat-EIR-fT", + "category": "DX Heating Coil", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tiadb", + "independent_variable_2": "Toadb", + "coeff_1": 0.99999417, + "coeff_2": 0.004684594, + "coeff_3": 5.90129e-05, + "coeff_4": -0.002862447, + "coeff_5": 1.30411e-05, + "coeff_6": -0.000161729, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -100, + "maximum_independent_variable_1": 100, + "minimum_independent_variable_2": -100, + "maximum_independent_variable_2": 100, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From OpenStudio-HPXML" + }, + { + "name": "Minisplit-Heat-EIR-fFF", + "category": "DX Heating Coil", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tiadb", + "independent_variable_2": "Toadb", + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 2, + "minimum_independent_variable_2": 0, + "maximum_independent_variable_2": 2, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From OpenStudio-HPXML" + }, + { + "name": "Minisplit-Heat-PLF-fPLR", + "category": "DX Heating Coil", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tiadb", + "independent_variable_2": "Toadb", + "coeff_1": 0.89, + "coeff_2": 0.11, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": 0.6, + "maximum_independent_variable_2": 1, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From OpenStudio-HPXML" + }, + { + "name": "Minisplit-Cool-Cap-fT", + "category": "DX Cooling Coil", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tiadb", + "independent_variable_2": "Toadb", + "coeff_1": 0.75319835, + "coeff_2": 0.003618194, + "coeff_3": 0, + "coeff_4": 0.006574385, + "coeff_5": -6.87181e-05, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 100, + "minimum_independent_variable_2": 0, + "maximum_independent_variable_2": 100, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From OpenStudio-HPXML" + }, + { + "name": "Minisplit-Cool-Cap-fFF", + "category": "DX Cooling Coil", + "form": "Quadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tiadb", + "independent_variable_2": "Toadb", + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 2, + "minimum_independent_variable_2": 0, + "maximum_independent_variable_2": 2, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From OpenStudio-HPXML" + }, + { + "name": "Minisplit-Cool-EIR-fT", + "category": "DX Cooling Coil", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tiadb", + "independent_variable_2": "Toadb", + "coeff_1": -0.063769248, + "coeff_2": -0.001336059, + "coeff_3": 1.41306e-05, + "coeff_4": 0.019433076, + "coeff_5": -4.91396e-05, + "coeff_6": -4.90934e-05, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 100, + "minimum_independent_variable_2": 0, + "maximum_independent_variable_2": 100, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From OpenStudio-HPXML" + }, + { + "name": "Minisplit-Cool-EIR-fFF", + "category": "DX Cooling Coil", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tiadb", + "independent_variable_2": "Toadb", + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 2, + "minimum_independent_variable_2": 0, + "maximum_independent_variable_2": 2, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From OpenStudio-HPXML" + }, + { + "name": "Minisplit-Cool-PLF-fPLR", + "category": "DX Cooling Coil", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tiadb", + "independent_variable_2": "Toadb", + "coeff_1": 0.89, + "coeff_2": 0.11, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": 0.6, + "maximum_independent_variable_2": 1, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From OpenStudio-HPXML" + }, + { + "name": "EFG-Si_Spectral-fAirMass", + "category": "PV-Module", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": "AirMass", + "independent_variable_2": null, + "coeff_1": 0.93235892, + "coeff_2": 0.05557786, + "coeff_3": -0.00723784, + "coeff_4": 0.00016577, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Elec-HW-Blr-EIR-fPLR", + "category": "ElecBoilers", + "form": "Linear", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.02, + "coeff_2": 0.98, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Elec-Stm-Blr-EIR-fPLR", + "category": "ElecBoilers", + "form": "Linear", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.03, + "coeff_2": 0.97, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Engine-Chlr-Cap-fCHWT&ECT", + "category": "EngineChiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 1.02245976, + "coeff_2": 0.033624396, + "coeff_3": 0, + "coeff_4": -0.00837585, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44444, + "maximum_independent_variable_1": 18.33333, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Engine-Chlr-HeatRej-fECT", + "category": "EngineChiller", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": "ECT", + "independent_variable_2": null, + "coeff_1": 0.81658293, + "coeff_2": 0.00622926, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 60, + "maximum_independent_variable_1": 150, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Engine-Chlr-HeatRej-fPLR", + "category": "EngineChiller", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 1.05269921, + "coeff_2": -0.05269912, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Engine-Chlr-HIR-fCHWT&ECT", + "category": "EngineChiller", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 0.76855672, + "coeff_2": -0.016619742, + "coeff_3": 0.001163452, + "coeff_4": 0.007451082, + "coeff_5": 0.000302, + "coeff_6": -0.000971, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44444, + "maximum_independent_variable_1": 18.33333, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Engine-Chlr-HIR-fPLR", + "category": "EngineChiller", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.12571636, + "coeff_2": 0.34714213, + "coeff_3": 0.52714163, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Engine-Exh-fPLR", + "category": "EngineGenerator", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.024516, + "coeff_2": 0.3323871, + "coeff_3": 0.6430968, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Engine-HIR-fPLR", + "category": "EngineGenerator", + "form": "Linear", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.107, + "coeff_2": 0.893, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Engine-Jac-fPLR", + "category": "EngineGenerator", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.287936, + "coeff_2": 1.0204516, + "coeff_3": -0.3083871, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "FluidCooler-FluidCap-fApp&WB", + "category": "FluidCooler", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "App", + "independent_variable_2": "WB", + "coeff_1": -0.16463568, + "coeff_2": 0.048677022, + "coeff_3": -0.001437296, + "coeff_4": 0.072275256, + "coeff_5": 0.000924, + "coeff_6": 0.005085439, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "FluidCooler-FluidCap-fRng&WB", + "category": "FluidCooler", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Rng", + "independent_variable_2": "WB", + "coeff_1": 0, + "coeff_2": 0.18, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ForcedDraft-Blr-HIR-fPLR", + "category": "FuelBoilers", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.01599992, + "coeff_2": 0.94495332, + "coeff_3": 0.03904687, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ForCurve w Dischrg Dampers FPLR", + "category": "FanEIR-FPLR", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.190667, + "coeff_2": 0.31, + "coeff_3": 0.5, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.22, + "maximum_dependent_variable_output": 1, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ForCurve w Inlet Vanes FPLR", + "category": "FanEIR-FPLR", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.339619, + "coeff_2": -0.848139, + "coeff_3": 1.495671, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.22, + "maximum_dependent_variable_output": 1, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "FURNACE_PACU_VAV_CoolCCarrier48TM014_12tons_EIRFFF", + "category": "DX Cooling Coil", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 1.19525, + "coeff_2": -0.306138, + "coeff_3": 0.110973, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.75, + "maximum_independent_variable_1": 1.25, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From PNNL OfficeMedium" + }, + { + "name": "FURNACE_PACU_VAV_CoolCCarrier48TM014_12tons_EIRFT", + "category": "DX Cooling Coil", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Twb", + "independent_variable_2": "Toadb", + "coeff_1": -0.536161, + "coeff_2": 0.105138, + "coeff_3": -0.00172659, + "coeff_4": 0.0149848, + "coeff_5": 0.000659948, + "coeff_6": -0.0017385, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 16.5556, + "maximum_independent_variable_1": 22.1111, + "minimum_independent_variable_2": 23.7778, + "maximum_independent_variable_2": 47.66, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From PNNL Prototype Buildings OfficeMedium" + }, + { + "name": "FURNACE-EFFPLR-NECB2011", + "category": "Gas Heating Coil", + "form": "Cubic", + "dependent_variable": "FIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.7277, + "coeff_2": 1.0667, + "coeff_3": -1.5174, + "coeff_4": 0.7282, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From NECB 2011" + }, + { + "name": "Furnace-HIR-fPLR", + "category": "Furnace", + "form": "Quadratic", + "dependent_variable": "FIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.0186, + "coeff_2": 1.09, + "coeff_3": -0.113, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Gas-Absor-Cap-fCHWT&ECT", + "category": "Chiller/Heater", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 0.362073, + "coeff_2": 0.0001386, + "coeff_3": 0.001458, + "coeff_4": 0.0733878, + "coeff_5": -0.00206064, + "coeff_6": 0.00101, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44444, + "maximum_independent_variable_1": 18.33333, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Gas-Absor-HCap-fCoolPLR", + "category": "Chiller/Heater", + "form": "Quadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "CoolPLR", + "independent_variable_2": null, + "coeff_1": 0.863599, + "coeff_2": -1.30495346, + "coeff_3": 0.44135284, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Gas-Absor-HIR-fCHWT&ECT", + "category": "Chiller/Heater", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 0.96182051, + "coeff_2": -0.0507105, + "coeff_3": 0.003155468, + "coeff_4": 0.005732838, + "coeff_5": 0.000349, + "coeff_6": -0.00118516, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44444, + "maximum_independent_variable_1": 18.33333, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Gas-Absor-HIR-fDesiccantT", + "category": "Chiller/Heater", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": "DesiccantT", + "independent_variable_2": null, + "coeff_1": 0.85427336, + "coeff_2": 0.002997504, + "coeff_3": 4.26e-05, + "coeff_4": 0, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 100, + "maximum_independent_variable_1": 300, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Gas-Absor-Qreg-fDesiccantT", + "category": "Chiller/Heater", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": "DesiccantT", + "independent_variable_2": null, + "coeff_1": 0.5984, + "coeff_2": -0.00234, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 100, + "maximum_independent_variable_1": 300, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GasTurbine-Cap-fPLR", + "category": "GasTurbineGen", + "form": "Linear", + "dependent_variable": "QRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 1.24, + "coeff_2": -0.0041, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GasTurbine-Exh-fPLR", + "category": "GasTurbineGen", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.295626, + "coeff_2": 0.4930194, + "coeff_3": 0.2113548, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GasTurbine-HIR-fPLR", + "category": "GasTurbineGen", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.442979, + "coeff_2": 0.3974, + "coeff_3": 0.1569621, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GHP-Bypass-Factor-fAirflow", + "category": "GasHeat-Pump", + "form": "Quadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Airflow", + "independent_variable_2": null, + "coeff_1": -0.254, + "coeff_2": 1.22, + "coeff_3": 0.036, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GHP-Bypass-Factor-fEWB&EDB", + "category": "GasHeat-Pump", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "EDB", + "coeff_1": 0.85028352, + "coeff_2": 0.014256792, + "coeff_3": 0.000184, + "coeff_4": -0.014791716, + "coeff_5": -5.48e-06, + "coeff_6": 0.000487, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GHP-Bypass-Factor-fPLR", + "category": "GasHeat-Pump", + "form": "Linear", + "dependent_variable": "QRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GHP-Cool-Cap-fEWB&OAT", + "category": "GasHeat-Pump", + "form": "BiLinear", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "OAT", + "coeff_1": 1.1688, + "coeff_2": 0.01926, + "coeff_3": -0.01539, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GHP-Cool-Cap-fRPM&OAT", + "category": "GasHeat-Pump", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "RPM", + "independent_variable_2": "OAT", + "coeff_1": -372.736, + "coeff_2": -234.129654, + "coeff_3": -36.65800433, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GHP-Cool-CondFan-fPLR&OAT", + "category": "GasHeat-Pump", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": "OAT", + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GHP-Cool-CycleLoss-fPLR", + "category": "GasHeat-Pump", + "form": "Linear", + "dependent_variable": "QRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.82, + "coeff_2": 0.18, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GHP-Cool-HIR-fEWB&OAT", + "category": "GasHeat-Pump", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "EWB", + "independent_variable_2": "OAT", + "coeff_1": 1.1386752, + "coeff_2": -0.049248, + "coeff_3": 0.000914, + "coeff_4": 0.02128896, + "coeff_5": 0.000306, + "coeff_6": -0.000953, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GHP-Cool-HIR-fRPM&OAT", + "category": "GasHeat-Pump", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "RPM", + "independent_variable_2": "OAT", + "coeff_1": -369.60598, + "coeff_2": -234.0532596, + "coeff_3": -36.93157152, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GHP-Cool-Waste-Heat-fEWB&OAT", + "category": "GasHeat-Pump", + "form": "BiLinear", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "OAT", + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GHP-Cool-Waste-Heat-fRPM&OAT", + "category": "GasHeat-Pump", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "RPM", + "independent_variable_2": "OAT", + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GHP-Defrost-Frac-fOWB&ODB", + "category": "GasHeat-Pump", + "form": "BiLinear", + "dependent_variable": "QRatio", + "independent_variable_1": "OWB", + "independent_variable_2": "ODB", + "coeff_1": 0.0333, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -23.33333, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.33333, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GHP-Heat-Cap-fEDB&OAT", + "category": "GasHeat-Pump", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EDB", + "independent_variable_2": "OAT", + "coeff_1": 0.8291632, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0.01817136, + "coeff_5": 0.000281, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.33333, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GHP-Heat-Cap-fRPM&OAT", + "category": "GasHeat-Pump", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "RPM", + "independent_variable_2": "OAT", + "coeff_1": 157.86, + "coeff_2": 89.17133162, + "coeff_3": 12.58409104, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": -23.33333, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GHP-Heat-CondFan-fPLR&OAT", + "category": "GasHeat-Pump", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": "OAT", + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": -23.33333, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GHP-Heat-CycleLoss-fPLR", + "category": "GasHeat-Pump", + "form": "Linear", + "dependent_variable": "QRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.82, + "coeff_2": 0.18, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GHP-Heat-HIR-fEDB&OAT", + "category": "GasHeat-Pump", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "EDB", + "independent_variable_2": "OAT", + "coeff_1": 1.14897728, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": -0.017395056, + "coeff_5": -2.6e-05, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.33333, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GHP-Heat-HIR-fRPM&OAT", + "category": "GasHeat-Pump", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "RPM", + "independent_variable_2": "OAT", + "coeff_1": 194.037, + "coeff_2": 109.788263, + "coeff_3": 15.50214113, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": -23.33333, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GHP-Heat-Waste-Heat-fEDB&OAT", + "category": "GasHeat-Pump", + "form": "BiLinear", + "dependent_variable": "QRatio", + "independent_variable_1": "EDB", + "independent_variable_2": "OAT", + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.33333, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GHP-Heat-Waste-Heat-fRPM&OAT", + "category": "GasHeat-Pump", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "RPM", + "independent_variable_2": "OAT", + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GHP-Sens-Cap-fEWB&OAT", + "category": "GasHeat-Pump", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "OAT", + "coeff_1": 1.49637568, + "coeff_2": 0.079056576, + "coeff_3": -0.004212, + "coeff_4": -0.030189312, + "coeff_5": 0.000157, + "coeff_6": 0.00062, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Glass Door Defrost Curve", + "category": "Refrigerated Case", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.3475, + "coeff_2": 0.0296, + "coeff_3": 0.0007, + "coeff_4": 3e-05, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -55, + "maximum_independent_variable_1": 55, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "For SuperMarket Prototype Buildings" + }, + { + "name": "Glass Door Latent Curve", + "category": "Refrigerated Case", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.3379, + "coeff_2": 0.0309, + "coeff_3": 0.0005, + "coeff_4": 4e-05, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -55, + "maximum_independent_variable_1": 55, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "For SuperMarket Prototype Buildings" + }, + { + "name": "GoodCyclingAC-EIR-fPLR", + "category": "CyclingAC", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 2.73e-06, + "coeff_2": 1.05259, + "coeff_3": -0.0552087, + "coeff_4": 0.00262236, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GSHP/WLHP_BF_fAirflow-Old", + "category": "GSHP/WLHPCurves", + "form": "Cubic", + "dependent_variable": "QRatio", + "independent_variable_1": "Airflow", + "independent_variable_2": null, + "coeff_1": -0.828, + "coeff_2": 14.3, + "coeff_3": -21.9, + "coeff_4": 9.4, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GSHP/WLHP_BF_fEwbEwt", + "category": "GSHP/WLHPCurves", + "form": "BiLinear", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "EWT", + "coeff_1": -0.2016, + "coeff_2": 0.0297, + "coeff_3": 0.02646, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.347365, + "maximum_dependent_variable_output": 1.67341, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GSHP/WLHP_BF_fEwbEwt-Old", + "category": "GSHP/WLHPCurves", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "EWT", + "coeff_1": -5.522656, + "coeff_2": 0.735768, + "coeff_3": -0.0185004, + "coeff_4": 0.1418832, + "coeff_5": 0.000943, + "coeff_6": -0.010206, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GSHP/WLHP_Cool_Cap_fEwbEwt", + "category": "GSHP/WLHPCurves", + "form": "BiLinear", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "EWT", + "coeff_1": 0.88114368, + "coeff_2": 0.015264, + "coeff_3": -0.007493418, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.803411, + "maximum_dependent_variable_output": 1.18555, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GSHP/WLHP_Cool_EIR_fEwbEwt", + "category": "GSHP/WLHPCurves", + "form": "BiLinear", + "dependent_variable": "EIRRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "EWT", + "coeff_1": 0.4111216, + "coeff_2": -0.00396, + "coeff_3": 0.03011184, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.300674, + "maximum_dependent_variable_output": 1.80627, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GSHP/WLHP_H/C_EIR-fPLR", + "category": "GSHP/WLHPCurves", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.0414, + "coeff_2": 0.328, + "coeff_3": 0.575337, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0, + "maximum_dependent_variable_output": 1, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GSHP/WLHP_H/C_EIR-fPLR-Old", + "category": "GSHP/WLHPCurves", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.00988, + "coeff_2": 1.08, + "coeff_3": -0.105, + "coeff_4": 0.0151, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GSHP/WLHP_Heat_Cap_fEdbEwt", + "category": "GSHP/WLHPCurves", + "form": "BiLinear", + "dependent_variable": "QRatio", + "independent_variable_1": "EDB", + "independent_variable_2": "EWT", + "coeff_1": 1.07264, + "coeff_2": -0.003564, + "coeff_3": 0.027, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.966284, + "maximum_dependent_variable_output": 1.86368, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "GSHP/WLHP_Heat_EIR_fEdbEwt", + "category": "GSHP/WLHPCurves", + "form": "BiLinear", + "dependent_variable": "EIRRatio", + "independent_variable_1": "EDB", + "independent_variable_2": "EWT", + "coeff_1": 0.59444, + "coeff_2": 0.01908, + "coeff_3": -0.009774, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.681922, + "maximum_dependent_variable_output": 1.10294, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "HeatSys1 Boiler Non-Condensing Boiler Curve", + "category": "Boiler", + "form": "Cubic", + "dependent_variable": "FIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.626428326, + "coeff_2": 0.645643582, + "coeff_3": -0.77720685, + "coeff_4": 0.313806701, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.1, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Prototype Buildings" + }, + { + "name": "HeatWheel-EIR-fSpeed", + "category": "ERVUnit", + "form": "Linear", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Speed", + "independent_variable_2": null, + "coeff_1": 25.8, + "coeff_2": 7.639437277, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Herm-Cent-Cap-fCHWT&ECT", + "category": "HermCentrifugal", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 0.257896, + "coeff_2": 0.0389016, + "coeff_3": -0.000217, + "coeff_4": 0.0468684, + "coeff_5": -0.000943, + "coeff_6": -0.000343, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44444, + "maximum_independent_variable_1": 18.33333, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Herm-Cent-EIR-fCHWT&ECT", + "category": "HermCentrifugal", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 0.933884, + "coeff_2": -0.058212, + "coeff_3": 0.00450036, + "coeff_4": 0.00243, + "coeff_5": 0.000486, + "coeff_6": -0.001215, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44444, + "maximum_independent_variable_1": 18.33333, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Herm-Cent-EIR-fPLR", + "category": "HermCentrifugal", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.222903, + "coeff_2": 0.313387, + "coeff_3": 0.46371, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 0.105, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Herm-Rec-Cap-fCHWT&ECT", + "category": "HermReciprocatg", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 0.507883, + "coeff_2": 0.1452276, + "coeff_3": -0.00625644, + "coeff_4": -0.0011178, + "coeff_5": -0.00013, + "coeff_6": -0.000282, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44444, + "maximum_independent_variable_1": 18.33333, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Herm-Rec-EIR-fCHWT&ECT", + "category": "HermReciprocatg", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 1.030757, + "coeff_2": -0.103536, + "coeff_3": 0.00710208, + "coeff_4": 0.0093186, + "coeff_5": 0.000318, + "coeff_6": -0.00104, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44444, + "maximum_independent_variable_1": 18.33333, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Herm-Rec-EIR-fPLR", + "category": "HermReciprocatg", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.088065, + "coeff_2": 1.137742, + "coeff_3": -0.225806, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Hospital Kitchen_Flr_5_Case:1_WALKINFREEZERSingleShelfHorizontal_LatentEnergyMult", + "category": "Refrigerated Case", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.0236, + "coeff_2": 0.0006, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -35, + "maximum_independent_variable_1": 20, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Prototype Buildings" + }, + { + "name": "Hospital Kitchen_Flr_5_Case:2_SELFCONTAINEDDISPLAYCASEMultiShelfVertical_LatentEnergyMult", + "category": "Refrigerated Case", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.026526281, + "coeff_2": 0.001078032, + "coeff_3": 6.02558e-05, + "coeff_4": 1.23732e-06, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -35, + "maximum_independent_variable_1": 20, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Prototype Buildings" + }, + { + "name": "HotelLarge Kitchen_Flr_6_Case:1_WALKINFREEZERSingleShelfHorizontal_LatentEnergyMult", + "category": "Refrigerated Case", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.0236, + "coeff_2": 0.0006, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -35, + "maximum_independent_variable_1": 20, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Prototype Buildings" + }, + { + "name": "HotelLarge Kitchen_Flr_6_Case:2_SELFCONTAINEDDISPLAYCASEMultiShelfVertical_LatentEnergyMult", + "category": "Refrigerated Case", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.026526281, + "coeff_2": 0.001078032, + "coeff_3": 6.02558e-05, + "coeff_4": 1.23732e-06, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -35, + "maximum_independent_variable_1": 20, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Prototype Buildings" + }, + { + "name": "HP-Bypass-Factor-fAirflow", + "category": "Water-LoopHP", + "form": "Cubic", + "dependent_variable": "QRatio", + "independent_variable_1": "Airflow", + "independent_variable_2": null, + "coeff_1": -0.828, + "coeff_2": 14.3, + "coeff_3": -21.9, + "coeff_4": 9.4, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "HP-Bypass-Factor-fEWB&EWT", + "category": "Water-LoopHP", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "EWT", + "coeff_1": -5.522656, + "coeff_2": 0.735768, + "coeff_3": -0.0185004, + "coeff_4": 0.1418832, + "coeff_5": 0.000943, + "coeff_6": -0.010206, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "HP-Cool-Cap-fEWB&EWT", + "category": "Water-LoopHP", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "EWT", + "coeff_1": 0.38053696, + "coeff_2": 0.041974272, + "coeff_3": -3.09e-05, + "coeff_4": -0.006642864, + "coeff_5": 2.28e-05, + "coeff_6": -8.81e-05, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "HP-Cool-EIR-fEWB&EWT", + "category": "Water-LoopHP", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "EWT", + "coeff_1": 1.3257696, + "coeff_2": -0.0504504, + "coeff_3": 0.000988, + "coeff_4": 0.02036448, + "coeff_5": 7.91e-05, + "coeff_6": -0.000531, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "HP-Cool-EIR-fPLR", + "category": "Water-LoopHP", + "form": "Linear", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.125, + "coeff_2": 0.875, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "HP-Heat-Cap-fEDB&EWT", + "category": "Water-LoopHP", + "form": "BiLinear", + "dependent_variable": "QRatio", + "independent_variable_1": "EDB", + "independent_variable_2": "EWT", + "coeff_1": 0.72324, + "coeff_2": -0.012204, + "coeff_3": 0.02538, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "HP-Heat-EIR-fEDB&EWT", + "category": "Water-LoopHP", + "form": "BiLinear", + "dependent_variable": "EIRRatio", + "independent_variable_1": "EDB", + "independent_variable_2": "EWT", + "coeff_1": 1.2124, + "coeff_2": 0.01089, + "coeff_3": -0.02088, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "HP-Heat-EIR-fPLR", + "category": "Water-LoopHP", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.0857, + "coeff_2": 0.939, + "coeff_3": -0.183, + "coeff_4": 0.15897022, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "HP-Sens-Cap-fAirflow", + "category": "Water-LoopHP", + "form": "Cubic", + "dependent_variable": "QRatio", + "independent_variable_1": "Airflow", + "independent_variable_2": null, + "coeff_1": -0.13, + "coeff_2": 2.16, + "coeff_3": -1.6, + "coeff_4": 0.573, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "HP-Sens-Cap-fEWB&EWT", + "category": "Water-LoopHP", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "EWT", + "coeff_1": 1.68318464, + "coeff_2": 0.012410496, + "coeff_3": -0.00215784, + "coeff_4": -0.009251064, + "coeff_5": 6.32e-05, + "coeff_6": 0.000174, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "HPACCoolCapFFF", + "category": "DX Cooling Coil", + "form": "Quadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.8, + "coeff_2": 0.2, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.5, + "maximum_independent_variable_1": 1.5, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": null + }, + { + "name": "HPACCoolCapFT", + "category": "DX Cooling Coil", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Twb", + "independent_variable_2": "Toadb", + "coeff_1": 0.766956, + "coeff_2": 0.0107756, + "coeff_3": -4.14703e-05, + "coeff_4": 0.00134961, + "coeff_5": -0.000261144, + "coeff_6": 0.000457488, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 23.88889, + "minimum_independent_variable_2": 21.11111, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": null + }, + { + "name": "HPACCOOLEIRFFF", + "category": "DX Cooling Coil", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 1.156, + "coeff_2": -0.1816, + "coeff_3": 0.0256, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.5, + "maximum_independent_variable_1": 1.5, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": null + }, + { + "name": "HPACCOOLEIRFT", + "category": "DX Cooling Coil", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Twb", + "independent_variable_2": "Toadb", + "coeff_1": 0.297145, + "coeff_2": 0.0430933, + "coeff_3": -0.000748766, + "coeff_4": 0.00597727, + "coeff_5": 0.000482112, + "coeff_6": -0.000956448, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 23.88889, + "minimum_independent_variable_2": 21.11111, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": null + }, + { + "name": "HPACCOOLPLFFPLR", + "category": "DX Cooling Coil", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.85, + "coeff_2": 0.15, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": null + }, + { + "name": "HPACHeatCapFFF", + "category": "DX Heating Coil", + "form": "Cubic", + "dependent_variable": "QRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.84, + "coeff_2": 0.16, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.5, + "maximum_independent_variable_1": 1.5, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Prototype Buildings" + }, + { + "name": "HPACHeatCapFT", + "category": "DX Heating Coil", + "form": "Cubic", + "dependent_variable": "QRatio", + "independent_variable_1": "Toadb", + "independent_variable_2": null, + "coeff_1": 0.758746, + "coeff_2": 0.027626, + "coeff_3": 0.000148716, + "coeff_4": 3.4992e-06, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -20, + "maximum_independent_variable_1": 20, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Prototype Buildings" + }, + { + "name": "HPACHeatEIRFFF", + "category": "DX Heating Coil", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 1.3824, + "coeff_2": -0.4336, + "coeff_3": 0.0512, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Prototype Buildings" + }, + { + "name": "HPACHeatEIRFT", + "category": "DX Heating Coil", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Toadb", + "independent_variable_2": null, + "coeff_1": 1.19248, + "coeff_2": -0.0300438, + "coeff_3": 0.00103745, + "coeff_4": -2.3328e-05, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -20, + "maximum_independent_variable_1": 20, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Prototype Buildings" + }, + { + "name": "Htrec-Chlr-Cap-fCHWT&ECT", + "category": "ElecHeatRecover", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 0.257896, + "coeff_2": 0.0389016, + "coeff_3": -0.000217, + "coeff_4": 0.0468684, + "coeff_5": -0.000943, + "coeff_6": -0.000343, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44444, + "maximum_independent_variable_1": 18.33333, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 51.66667, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Htrec-Chlr-EIR-fCHWT&ECT", + "category": "ElecHeatRecover", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 0.933884, + "coeff_2": -0.058212, + "coeff_3": 0.00450036, + "coeff_4": 0.00243, + "coeff_5": 0.000486, + "coeff_6": -0.001215, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44444, + "maximum_independent_variable_1": 18.33333, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 51.66667, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Htrec-Chlr-EIR-fPLR", + "category": "ElecHeatRecover", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.349032, + "coeff_2": 0.263871, + "coeff_3": 0.387097, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Htrej-Fan-Pwr-fDamper", + "category": "FluidCooler", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": "Damper", + "independent_variable_2": null, + "coeff_1": 0.37607971, + "coeff_2": -0.21440694, + "coeff_3": 1.00540793, + "coeff_4": -0.16712119, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.36, + "maximum_dependent_variable_output": 1, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "HW-Coil-Cap-fAirflow", + "category": "HWCoils", + "form": "Quadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Airflow", + "independent_variable_2": null, + "coeff_1": 0.289, + "coeff_2": 1.03, + "coeff_3": -0.317, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "HW-Coil-Cap-fdT", + "category": "HWCoils", + "form": "Quadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "dT", + "independent_variable_2": null, + "coeff_1": -0.00467, + "coeff_2": 1.8, + "coeff_3": 0.010960272, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 150, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.01, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "HW-Coil-Cap-fFluidFlow", + "category": "HWCoils", + "form": "Quadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "FluidFlow", + "independent_variable_2": null, + "coeff_1": 0.18, + "coeff_2": 2945.2432, + "coeff_3": -2540000, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Indirect-Effectiveness-fFlow", + "category": "EvapCooler", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "Flow", + "independent_variable_2": null, + "coeff_1": 1.1, + "coeff_2": -350, + "coeff_3": 306000, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Inverter_EIR-fPLR", + "category": "PV-Inverter", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.01677774, + "coeff_2": 1.03766656, + "coeff_3": -0.05444431, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Large-CHW-Bypass-fAirflow", + "category": "CHWCoils", + "form": "Quadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Airflow", + "independent_variable_2": null, + "coeff_1": 0.397, + "coeff_2": 0.15, + "coeff_3": 0.45374713, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Large-CHW-Coil-Bypass-fEWB&EDB", + "category": "CHWCoils", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "EDB", + "coeff_1": 0.435936, + "coeff_2": 0.23652, + "coeff_3": -0.0047628, + "coeff_4": -0.1330272, + "coeff_5": 0.00119556, + "coeff_6": 0.000859, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 15.55556, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Large-CHW-Coil-Cap-fEWB&EDB", + "category": "CHWCoils", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "EDB", + "coeff_1": 0.09793216, + "coeff_2": -0.13886496, + "coeff_3": 0.0124416, + "coeff_4": 0.088907328, + "coeff_5": 0.001938946, + "coeff_6": -0.009305604, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 15.55556, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Large-CHW-Sens-Cap-fAirflow", + "category": "CHWCoils", + "form": "Quadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Airflow", + "independent_variable_2": null, + "coeff_1": 0.202, + "coeff_2": 0.855, + "coeff_3": -0.057, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Large-CHW-Sens-Cap-fEWB&EDB", + "category": "CHWCoils", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "EDB", + "coeff_1": 0.12076864, + "coeff_2": -0.124558848, + "coeff_3": 0.0063828, + "coeff_4": 0.11146032, + "coeff_5": 0.001847902, + "coeff_6": -0.006508285, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 15.55556, + "maximum_independent_variable_1": 13.33333, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Lp2Lp_Cap_fCHW&HWR", + "category": "Loop2Loop", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "HWR", + "coeff_1": 0.95122179, + "coeff_2": 0.035393436, + "coeff_3": 0.00027, + "coeff_4": -0.002654118, + "coeff_5": -8.69e-05, + "coeff_6": -0.000274, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Lp2Lp_EIR_fCHW&HWR", + "category": "Loop2Loop", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "HWR", + "coeff_1": 0.59918703, + "coeff_2": -0.00950724, + "coeff_3": 0.000335, + "coeff_4": 0.00863883, + "coeff_5": 0.000312, + "coeff_6": -0.000386, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Lp2Lp-EIR-fPLR-1Comp/Ckt", + "category": "Loop2Loop", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.03481113, + "coeff_2": 0.95945376, + "coeff_3": 0.00573495, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Lp2Lp-EIR-fPLR-2Comp/Ckt", + "category": "Loop2Loop", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.02297712, + "coeff_2": 0.90150452, + "coeff_3": 0.07551826, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "LT_compressor_capacity", + "category": "Refrigeration", + "form": "BiCubic", + "dependent_variable": "Capacity", + "independent_variable_1": "Suction T", + "independent_variable_2": "Discharge T", + "coeff_1": 170751.834, + "coeff_2": 6102.9037, + "coeff_3": 78.2619862, + "coeff_4": -2959.4326, + "coeff_5": 19.7876589, + "coeff_6": -90.958101, + "coeff_7": 0.43596477, + "coeff_8": -0.0411577, + "coeff_9": -0.608846, + "coeff_10": 0.459133262, + "minimum_independent_variable_1": -40, + "maximum_independent_variable_1": 17.8, + "minimum_independent_variable_2": 4.4, + "maximum_independent_variable_2": 54.4, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From AEDG" + }, + { + "name": "LT_compressor_power", + "category": "Refrigeration", + "form": "BiCubic", + "dependent_variable": "Power", + "independent_variable_1": "Suction T", + "independent_variable_2": "Discharge T", + "coeff_1": 29669.2711, + "coeff_2": 1027.63205, + "coeff_3": 18.1066262, + "coeff_4": -442.19971, + "coeff_5": 11.1335288, + "coeff_6": -20.380452, + "coeff_7": 0.13998065, + "coeff_8": -0.0588669, + "coeff_9": -0.2184515, + "coeff_10": 0.203858467, + "minimum_independent_variable_1": -40, + "maximum_independent_variable_1": -17.8, + "minimum_independent_variable_2": 4.4, + "maximum_independent_variable_2": 54.4, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From AEDG" + }, + { + "name": "mc-Si_Spectral-fAirMass", + "category": "PV-Module", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": "AirMass", + "independent_variable_2": null, + "coeff_1": 0.96113414, + "coeff_2": 0.02820018, + "coeff_3": -0.00134585, + "coeff_4": -0.00012036, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Measured_CoolCStandard10Ton_EIRFFF", + "category": "DX Cooling Coil", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 1.192, + "coeff_2": -0.1917, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.776, + "maximum_independent_variable_1": 1.197, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From PNNL Prototype FullServiceRestaurant" + }, + { + "name": "MNECB-CAP-FAPP&WB", + "category": "CAP-FAPP&WB", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "App", + "independent_variable_2": "WB", + "coeff_1": -0.05425558, + "coeff_2": -0.063981648, + "coeff_3": 0.026052289, + "coeff_4": 0.260016714, + "coeff_5": 0.000809093, + "coeff_6": 0.015903767, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "MNECB-CAP-FRNG&WB", + "category": "CAP-FRNG&WB", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Rng", + "independent_variable_2": "WB", + "coeff_1": 188.8588489, + "coeff_2": 0.300231774, + "coeff_3": -0.045692003, + "coeff_4": 35.40844622, + "coeff_5": 0.601350934, + "coeff_6": 0.78576062, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "MNECB-Centrif-CAP-FT", + "category": "Centrif-CAP-FT", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0.70790824, + "coeff_2": -0.002006568, + "coeff_3": -0.00259605, + "coeff_4": 0.030058776, + "coeff_5": -0.001056434, + "coeff_6": 0.002045704, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "MNECB-Centrif-EIR-FPLR", + "category": "Centrif-EIR-FPLR", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.17149273, + "coeff_2": 0.58820208, + "coeff_3": 0.23737257, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "MNECB-Centrif-EIR-FT", + "category": "Centrif-EIR-FT", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0.5605438, + "coeff_2": -0.01377927, + "coeff_3": 6.57e-05, + "coeff_4": 0.013219362, + "coeff_5": 0.000268596, + "coeff_6": -0.000501131, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "MNECB-DW-HIR-fPLR", + "category": "DHW-HIR", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.021826, + "coeff_2": 0.97763, + "coeff_3": 0.000543, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "MNECB-HW-HIR-fPLR", + "category": "HW-HIR", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.082597, + "coeff_2": 0.996764, + "coeff_3": -0.079361, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "MNECB-Recip-CAP-FT", + "category": "Recip-CAP-FT", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 1.0303123, + "coeff_2": 0.033469794, + "coeff_3": 0.00023639, + "coeff_4": -0.007295868, + "coeff_5": -2.32e-05, + "coeff_6": -0.000148943, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "MNECB-Recip-EIR-FPLR", + "category": "Recip-EIR-FPLR", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.08144133, + "coeff_2": 0.41927141, + "coeff_3": 0.49939604, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "MNECB-Recip-EIR-FT", + "category": "Recip-EIR-FT", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0.49969897, + "coeff_2": -0.013084056, + "coeff_3": 0.000266425, + "coeff_4": 0.016592526, + "coeff_5": 0.000185393, + "coeff_6": -0.000375646, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Multi Shelf Vertical Latent Energy Multiplier", + "category": "Refrigerated Case", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.026526281, + "coeff_2": 0.001078032, + "coeff_3": -6.02558e-05, + "coeff_4": 1.23732e-06, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -35, + "maximum_independent_variable_1": 20, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Reference Buildings" + }, + { + "name": "Multi Zone VAV with Airfoil or Backward Incline riding the curve", + "category": "FanEIR-FPLR", + "form": "Cubic", + "dependent_variable": "PwrRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.1631, + "coeff_2": 1.5901, + "coeff_3": -0.8817, + "coeff_4": 0.1281, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.7, + "maximum_dependent_variable_output": null, + "annotation": "From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method" + }, + { + "name": "Multi Zone VAV with Airfoil or Backward Incline with inlet vanes", + "category": "FanEIR-FPLR", + "form": "Cubic", + "dependent_variable": "PwrRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.9977, + "coeff_2": -0.659, + "coeff_3": 0.9547, + "coeff_4": -0.2936, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.5, + "maximum_dependent_variable_output": null, + "annotation": "From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method" + }, + { + "name": "Multi Zone VAV with Forward Curved fans riding the curve", + "category": "FanEIR-FPLR", + "form": "Cubic", + "dependent_variable": "PwrRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.1224, + "coeff_2": 0.612, + "coeff_3": 0.5983, + "coeff_4": -0.3334, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.3, + "maximum_dependent_variable_output": null, + "annotation": "From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method" + }, + { + "name": "Multi Zone VAV with Forward Curved with inlet vanes", + "category": "FanEIR-FPLR", + "form": "Cubic", + "dependent_variable": "PwrRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.3038, + "coeff_2": -0.7608, + "coeff_3": 2.2729, + "coeff_4": -0.8169, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.3, + "maximum_dependent_variable_output": null, + "annotation": "From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method" + }, + { + "name": "Multi zone VAV with static pressure reset", + "category": "FanEIR-FPLR", + "form": "Cubic", + "dependent_variable": "PwrRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.040759894, + "coeff_2": 0.08804497, + "coeff_3": -0.07292612, + "coeff_4": 0.943739823, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.1, + "maximum_dependent_variable_output": null, + "annotation": "OpenStudio default, baseline for System Types 5-8 from ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method" + }, + { + "name": "Multi Zone VAV with vane-axial with variable pitch blades", + "category": "FanEIR-FPLR", + "form": "Cubic", + "dependent_variable": "PwrRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.1639, + "coeff_2": -0.4016, + "coeff_3": 1.9909, + "coeff_4": -0.7541, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.2, + "maximum_dependent_variable_output": null, + "annotation": "From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method" + }, + { + "name": "Multi Zone VAV with VSD and fixed SP setpoint", + "category": "FanEIR-FPLR", + "form": "Cubic", + "dependent_variable": "PwrRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.0013, + "coeff_2": 0.147, + "coeff_3": 0.9506, + "coeff_4": -0.0998, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.2, + "maximum_dependent_variable_output": null, + "annotation": "Appendix G baseline from ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method" + }, + { + "name": "New_Low_Temp_Comp_Cap_Curve", + "category": null, + "form": "BiCubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 58336.861, + "coeff_2": 1561.7435, + "coeff_3": 6.6068129, + "coeff_4": -283.65007, + "coeff_5": -0.12023494, + "coeff_6": -12.495749, + "coeff_7": -0.11627856, + "coeff_8": 0.002277001, + "coeff_9": -0.11814833, + "coeff_10": 0.032839613, + "minimum_independent_variable_1": -40, + "maximum_independent_variable_1": -17.8, + "minimum_independent_variable_2": 4.4, + "maximum_independent_variable_2": 54.4, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": null + }, + { + "name": "New_Low_Temp_Comp_Pwr_Curve", + "category": null, + "form": "BiCubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 6274.9904, + "coeff_2": 61.390661, + "coeff_3": 1.6208537, + "coeff_4": 129.11279, + "coeff_5": 0.87411617, + "coeff_6": 1.9581173, + "coeff_7": 0.030293311, + "coeff_8": 0.005754678, + "coeff_9": 0.004653957, + "coeff_10": -0.000749905, + "minimum_independent_variable_1": -40, + "maximum_independent_variable_1": -17.8, + "minimum_independent_variable_2": 4.4, + "maximum_independent_variable_2": 54.4, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": null + }, + { + "name": "New_Med_Temp_Comp_Cap_Curve", + "category": null, + "form": "BiCubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 61412.175, + "coeff_2": 1570.8519, + "coeff_3": 13.533449, + "coeff_4": -500.19524, + "coeff_5": 8.1639124, + "coeff_6": -3.6895385, + "coeff_7": 0.054485574, + "coeff_8": -0.088096805, + "coeff_9": 0.006381584, + "coeff_10": -0.037503058, + "minimum_independent_variable_1": -23.3, + "maximum_independent_variable_1": 7.2, + "minimum_independent_variable_2": 10, + "maximum_independent_variable_2": 60, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": null + }, + { + "name": "New_Med_Temp_Comp_Pwr_Curve", + "category": null, + "form": "BiCubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 4994.0336, + "coeff_2": 170.24972, + "coeff_3": 2.8463891, + "coeff_4": 356.79403, + "coeff_5": -6.3074704, + "coeff_6": -1.409856, + "coeff_7": 0.012160476, + "coeff_8": 0.076231729, + "coeff_9": -0.057527471, + "coeff_10": 0.009054446, + "minimum_independent_variable_1": -23.3, + "maximum_independent_variable_1": 7.2, + "minimum_independent_variable_2": 10, + "maximum_independent_variable_2": 60, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": null + }, + { + "name": "No SP Reset VSD Fan", + "category": "FanEIR-FPLR", + "form": "Cubic", + "dependent_variable": "PwrRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.070428852, + "coeff_2": 0.385330201, + "coeff_3": -0.460864118, + "coeff_4": 1.00920344, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.1, + "maximum_dependent_variable_output": null, + "annotation": "From California Energy Commision, \"Advanced Variable Air Volume System Design Guide,\" October 2004" + }, + { + "name": "Old_Low_Temp_Comp_Cap_Curve", + "category": null, + "form": "BiCubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 170751.834, + "coeff_2": 6102.9037, + "coeff_3": 78.2619862, + "coeff_4": -2959.43265, + "coeff_5": 19.7876589, + "coeff_6": -90.9581015, + "coeff_7": 0.435964768, + "coeff_8": -0.041157653, + "coeff_9": -0.60884596, + "coeff_10": 0.459133262, + "minimum_independent_variable_1": -40, + "maximum_independent_variable_1": -17.8, + "minimum_independent_variable_2": 4.4, + "maximum_independent_variable_2": 54.4, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": null + }, + { + "name": "Old_Low_Temp_Comp_Pwr_Curve", + "category": null, + "form": "BiCubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 29669.2711, + "coeff_2": 1027.63205, + "coeff_3": 18.1066262, + "coeff_4": -442.199714, + "coeff_5": 11.1335288, + "coeff_6": -20.3804519, + "coeff_7": 0.139980653, + "coeff_8": -0.058866918, + "coeff_9": -0.218451538, + "coeff_10": 0.203858467, + "minimum_independent_variable_1": -40, + "maximum_independent_variable_1": -17.8, + "minimum_independent_variable_2": 4.4, + "maximum_independent_variable_2": 54.4, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": null + }, + { + "name": "Old_Med_Temp_Comp_Cap_Curve", + "category": null, + "form": "BiCubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 151166.436, + "coeff_2": 5266.34789, + "coeff_3": 60.6727151, + "coeff_4": -1851.55938, + "coeff_5": 5.73132755, + "coeff_6": -46.9277173, + "coeff_7": 0.136401203, + "coeff_8": -0.035697884, + "coeff_9": -0.403053994, + "coeff_10": -0.039290478, + "minimum_independent_variable_1": -23.3, + "maximum_independent_variable_1": 7.2, + "minimum_independent_variable_2": 10, + "maximum_independent_variable_2": 60, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": null + }, + { + "name": "Old_Med_Temp_Comp_Pwr_Curve", + "category": null, + "form": "BiCubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 7438.92229, + "coeff_2": -269.597565, + "coeff_3": -9.85610446, + "coeff_4": 553.57326, + "coeff_5": -3.38588961, + "coeff_6": 14.8657878, + "coeff_7": -0.100796292, + "coeff_8": 0.009822793, + "coeff_9": 0.097362356, + "coeff_10": -0.039675217, + "minimum_independent_variable_1": -23.3, + "maximum_independent_variable_1": 7.2, + "minimum_independent_variable_2": 10, + "maximum_independent_variable_2": 60, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": null + }, + { + "name": "Open Latent Curve", + "category": "Refrigerated Case", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": -0.0187, + "coeff_2": 0.0458, + "coeff_3": 0.0011, + "coeff_4": 5e-05, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -55, + "maximum_independent_variable_1": 55, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "For SuperMarket Prototype Buildings" + }, + { + "name": "Open-Cent-Cap-fCHWT&ECT", + "category": "OpenCentrifugal", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 0.257896, + "coeff_2": 0.0389016, + "coeff_3": -0.000217, + "coeff_4": 0.0468684, + "coeff_5": -0.000943, + "coeff_6": -0.000343, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44444, + "maximum_independent_variable_1": 18.33333, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Open-Cent-EIR-fCHWT&ECT", + "category": "OpenCentrifugal", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 0.933884, + "coeff_2": -0.058212, + "coeff_3": 0.00450036, + "coeff_4": 0.00243, + "coeff_5": 0.000486, + "coeff_6": -0.001215, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44444, + "maximum_independent_variable_1": 18.33333, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Open-Cent-EIR-fPLR", + "category": "OpenCentrifugal", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.222903, + "coeff_2": 0.313387, + "coeff_3": 0.46371, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Open-Rec-Cap-fCHWT&ECT", + "category": "OpenReciprocatg", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 0.507883, + "coeff_2": 0.1452276, + "coeff_3": -0.00625644, + "coeff_4": -0.0011178, + "coeff_5": -0.00013, + "coeff_6": -0.000282, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44444, + "maximum_independent_variable_1": 18.33333, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Open-Rec-EIR-fCHWT&ECT", + "category": "OpenReciprocatg", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 1.030757, + "coeff_2": -0.103536, + "coeff_3": 0.00710208, + "coeff_4": 0.0093186, + "coeff_5": 0.000318, + "coeff_6": -0.00104, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 4.44444, + "maximum_independent_variable_1": 18.33333, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Open-Rec-EIR-fPLR", + "category": "OpenReciprocatg", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.088065, + "coeff_2": 1.137742, + "coeff_3": -0.225806, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "OpenTwr-FluidCap-fApp&WB", + "category": "OpenTower", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "App", + "independent_variable_2": "WB", + "coeff_1": 0.11735985, + "coeff_2": 0.010588518, + "coeff_3": 0.000701, + "coeff_4": 0.052439526, + "coeff_5": 0.000724, + "coeff_6": 0.003437899, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "OpenTwr-FluidCap-fRng&WB", + "category": "OpenTower", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Rng", + "independent_variable_2": "WB", + "coeff_1": 0.11661702, + "coeff_2": 0.202450932, + "coeff_3": -0.004401443, + "coeff_4": -0.01592307, + "coeff_5": 0.000101, + "coeff_6": -0.001101632, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PoorCyclingAC-EIR-fPLR", + "category": "CyclingAC", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.000362523, + "coeff_2": 1.32573, + "coeff_3": -0.407603, + "coeff_4": 0.0818194, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PSZ-AC DX Coil EIR-FT", + "category": "DX Cooling Coil", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Twb", + "independent_variable_2": "Toadb", + "coeff_1": 0.342414409, + "coeff_2": 0.034885008, + "coeff_3": -0.0006237, + "coeff_4": 0.004977216, + "coeff_5": 0.000437951, + "coeff_6": -0.000728028, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 23.88889, + "minimum_independent_variable_2": 23.88889, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From PNNL Prototype Buildings HotelSmall, Warehouse" + }, + { + "name": "PSZ-AC DX Unitary Package EIRFT", + "category": "DX Cooling Coil", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Twb", + "independent_variable_2": "Toadb", + "coeff_1": 0.297145, + "coeff_2": 0.0430933, + "coeff_3": -0.000748766, + "coeff_4": 0.00597727, + "coeff_5": 0.000482112, + "coeff_6": -0.000956448, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 23.88889, + "minimum_independent_variable_2": 21.11111, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From PNNL Prototype Buildings RetailStandAlone, RetailStripMall,SchoolPrimary" + }, + { + "name": "PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT", + "category": "DX Cooling Coil", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Twb", + "independent_variable_2": "Toadb", + "coeff_1": 0.42415, + "coeff_2": 0.04426, + "coeff_3": -0.00042, + "coeff_4": 0.00333, + "coeff_5": -8e-05, + "coeff_6": -0.00021, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 17, + "maximum_independent_variable_1": 22, + "minimum_independent_variable_2": 29, + "maximum_independent_variable_2": 46, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" + }, + { + "name": "PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR", + "category": "DX Cooling Coil", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.771, + "coeff_2": 0.229, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" + }, + { + "name": "PSZ-AC_CoolCStandard10Ton_EIRFT", + "category": "DX Cooling Coil", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Twb", + "independent_variable_2": "Toadb", + "coeff_1": 1.23649, + "coeff_2": -0.02431, + "coeff_3": 0.00057, + "coeff_4": -0.01434, + "coeff_5": 0.00063, + "coeff_6": -0.00038, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 17, + "maximum_independent_variable_1": 22, + "minimum_independent_variable_2": 29, + "maximum_independent_variable_2": 46, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" + }, + { + "name": "PSZ-AC_Unitary_PackagecoolCapFT", + "category": "DX Cooling Coil", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Twb", + "independent_variable_2": "Toadb", + "coeff_1": 0.766956, + "coeff_2": 0.0107756, + "coeff_3": -4.14703e-05, + "coeff_4": 0.00134961, + "coeff_5": -0.000261144, + "coeff_6": 0.000457488, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 23.88889, + "minimum_independent_variable_2": 21.11111, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From PNNL Prototype Buildings RetailStandalone, RetailStripMall, SchoolPrimary" + }, + { + "name": "PSZ-AC_Unitary_PackagecoolEIRFFF", + "category": "DX Cooling Coil", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 1.156, + "coeff_2": -0.1816, + "coeff_3": 0.0256, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.5, + "maximum_independent_variable_1": 1.5, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": null + }, + { + "name": "PSZ-AC_Unitary_PackagecoolFFF", + "category": "DX Cooling Coil", + "form": "Quadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.8, + "coeff_2": 0.2, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.5, + "maximum_independent_variable_1": 1.5, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": null + }, + { + "name": "PSZ-AC_Unitary_PackagecoolPLR", + "category": "DX Cooling Coil", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.75, + "coeff_2": 0.25, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From PNNL Prototype Buildings RetailStandAlone, RetailStripMall, SchoolPrimary" + }, + { + "name": "PSZ-AC:1_Unitary_PackagecoolEIRFFF", + "category": "DX Cooling Coil", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 1.156, + "coeff_2": -0.1816, + "coeff_3": 0.0256, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.5, + "maximum_independent_variable_1": 1.5, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From PNNL Prototype Buildings RetailStandAlone, RetailStripMall, SchoolPrimary" + }, + { + "name": "PSZ-Fine Storage DX Coil Cap-FT", + "category": "DX Cooling Coil", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Twb", + "independent_variable_2": "Toadb", + "coeff_1": 0.942587793, + "coeff_2": 0.009543347, + "coeff_3": 0.00068377, + "coeff_4": -0.011042676, + "coeff_5": 5.249e-06, + "coeff_6": -9.72e-06, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 23.88889, + "minimum_independent_variable_2": 23.88889, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From PNNL Prototype Buildings HotelSmall, Warehouse" + }, + { + "name": "PSZ-Fine Storage Heating Coil PLF-FPLR", + "category": "DX Heating Coil", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.8, + "coeff_2": 0.2, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Prototype Buildings" + }, + { + "name": "PSZ-Office Heating Coil PLF-FPLR", + "category": "DX Heating Coil", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.8, + "coeff_2": 0.2, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Prototype Buildings" + }, + { + "name": "PSZ135to240_BF_fFlow", + "category": "BF_fFlow", + "form": "Linear", + "dependent_variable": null, + "independent_variable_1": "Flow", + "independent_variable_2": null, + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0, + "maximum_dependent_variable_output": 1, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PSZ135to240_BF_fT", + "category": "BF_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 43.269632, + "coeff_2": -4.898304, + "coeff_3": 0.148392, + "coeff_4": 0.0947376, + "coeff_5": 0.00213192, + "coeff_6": -0.0134136, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0, + "maximum_dependent_variable_output": 4.04, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PSZ135to240_CEIR_fPLR", + "category": "CEIR_fPLR", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.0184, + "coeff_2": 1.15, + "coeff_3": -0.208, + "coeff_4": 0.0423, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PSZ135to240_ClCap_fT", + "category": "ClCap_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 1.62774528, + "coeff_2": -0.060192, + "coeff_3": 0.00260172, + "coeff_4": -0.005653656, + "coeff_5": 2.66e-05, + "coeff_6": -0.00040824, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PSZ135to240_CLoss_fPLR", + "category": "CLoss_fPLR", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.852, + "coeff_2": 0.203, + "coeff_3": -0.0423, + "coeff_4": 0.00938, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.8024, + "maximum_dependent_variable_output": 1.0728, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PSZ135to240_ClSH_fT", + "category": "ClSH_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0.4018688, + "coeff_2": 0.1920384, + "coeff_3": -0.0077436, + "coeff_4": -0.01956816, + "coeff_5": -4.15e-05, + "coeff_6": 0.00077436, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PSZ135to240_EIR_fT", + "category": "EIR_fT", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": -0.0449056, + "coeff_2": 0.07059456, + "coeff_3": -0.00216432, + "coeff_4": 0.00440856, + "coeff_5": 0.00041148, + "coeff_6": -0.000245916, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PSZ135to240_HIR_fT", + "category": "HIR_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PSZ135to240_HtCap_fT", + "category": "HtCap_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PSZ240to760_BF_fFlow", + "category": "BF_fFlow", + "form": "Linear", + "dependent_variable": "QRatio", + "independent_variable_1": "Flow", + "independent_variable_2": null, + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0, + "maximum_dependent_variable_output": 1, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PSZ240to760_BF_fT", + "category": "BF_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 15.8724544, + "coeff_2": -1.6604928, + "coeff_3": 0.041148, + "coeff_4": 0.03013992, + "coeff_5": 0.000278964, + "coeff_6": 0.00047628, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0, + "maximum_dependent_variable_output": 3.252, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PSZ240to760_CEIR_fPLR", + "category": "CEIR_fPLR", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 2.63, + "coeff_2": -9.5, + "coeff_3": 14.3, + "coeff_4": -6.4, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PSZ240to760_ClCap_fT", + "category": "ClCap_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 1.27910208, + "coeff_2": -0.0291096, + "coeff_3": 0.00167184, + "coeff_4": -0.002266416, + "coeff_5": -3.1e-05, + "coeff_6": -0.00033372, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PSZ240to760_CLoss_fPLR", + "category": "CLoss_fPLR", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.964, + "coeff_2": 0.289, + "coeff_3": 0.183, + "coeff_4": -0.131, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.96, + "maximum_dependent_variable_output": 1.3, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PSZ240to760_ClSH_fT", + "category": "ClSH_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 2.64083712, + "coeff_2": -0.06152112, + "coeff_3": -0.0004698, + "coeff_4": -0.010834704, + "coeff_5": -2.89e-05, + "coeff_6": 0.000222912, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PSZ240to760_EIR_fT", + "category": "EIR_fT", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0.336608, + "coeff_2": 0.0487944, + "coeff_3": -0.00116316, + "coeff_4": -0.005994, + "coeff_5": 0.00067716, + "coeff_6": -0.00069012, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PSZ240to760_HIR_fT", + "category": "HIR_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PSZ240to760_HtCap_fT", + "category": "HtCap_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PSZ65to135_BF_fFlow", + "category": "BF_fFlow", + "form": "Linear", + "dependent_variable": null, + "independent_variable_1": "Flow", + "independent_variable_2": null, + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0, + "maximum_dependent_variable_output": 1, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PSZ65to135_BF_fT", + "category": "BF_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 14.931264, + "coeff_2": -1.5724512, + "coeff_3": 0.04698, + "coeff_4": 0.0015984, + "coeff_5": 0.00096552, + "coeff_6": -0.00319788, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0, + "maximum_dependent_variable_output": 3.509, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PSZ65to135_CEIR_fPLR", + "category": "CEIR_fPLR", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.0184, + "coeff_2": 1.15, + "coeff_3": -0.208, + "coeff_4": 0.0423, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PSZ65to135_ClCap_fT", + "category": "ClCap_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 1.2518496, + "coeff_2": -0.02766672, + "coeff_3": 0.00115344, + "coeff_4": 0.0035388, + "coeff_5": -0.000134136, + "coeff_6": -0.000167508, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PSZ65to135_CLoss_fPLR", + "category": "CLoss_fPLR", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.882, + "coeff_2": 0.211, + "coeff_3": -0.0439, + "coeff_4": 0.0098, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.8323, + "maximum_dependent_variable_output": 1.1087, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PSZ65to135_ClSH_fT", + "category": "ClSH_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 1.7733472, + "coeff_2": 0.0383688, + "coeff_3": -0.0038556, + "coeff_4": -0.01090224, + "coeff_5": -0.000138348, + "coeff_6": 0.00070632, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PSZ65to135_EIR_fT", + "category": "EIR_fT", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0.5431072, + "coeff_2": 0.03102048, + "coeff_3": -0.00090072, + "coeff_4": -0.01496592, + "coeff_5": 0.0006966, + "coeff_6": -0.000199908, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PSZ65to135_HIR_fT", + "category": "HIR_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PSZ65to135_HtCap_fT", + "category": "HtCap_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PTAC_EIR_fPLR", + "category": "PkgdTerminalACS", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.125, + "coeff_2": 0.875, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PTAC-Bypass-Factor-fAirflow", + "category": "PkgdTerminalAC", + "form": "Quadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Airflow", + "independent_variable_2": null, + "coeff_1": -2.28, + "coeff_2": 5.21, + "coeff_3": -1.93, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PTAC-Bypass-Factor-fEWB&EDB", + "category": "PkgdTerminalAC", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "EDB", + "coeff_1": -0.219664, + "coeff_2": 0.0994608, + "coeff_3": 0.00102, + "coeff_4": -0.020394, + "coeff_5": 0.00036, + "coeff_6": -0.00120528, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 21.11111, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PTAC-Cool-Cap-fEWB&OAT", + "category": "PkgdTerminalAC", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "OAT", + "coeff_1": 0.93865088, + "coeff_2": 0.0095364, + "coeff_3": 0.000684, + "coeff_4": -0.011038176, + "coeff_5": 5.25e-06, + "coeff_6": -9.72e-06, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 21.11111, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PTAC-EIR-fEWB&OAT", + "category": "PkgdTerminalAC", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "OAT", + "coeff_1": 0.34208928, + "coeff_2": 0.03484368, + "coeff_3": -0.000625, + "coeff_4": 0.004968864, + "coeff_5": 0.000438, + "coeff_6": -0.000728, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 21.11111, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PTAC-EIR-fPLR", + "category": "PkgdTerminalAC", + "form": "Linear", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.125, + "coeff_2": 0.875, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PTAC-Sens-Cap-fAirflow", + "category": "PkgdTerminalAC", + "form": "Linear", + "dependent_variable": "QRatio", + "independent_variable_1": "Airflow", + "independent_variable_2": null, + "coeff_1": 0.6, + "coeff_2": 0.4, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PTAC-Sens-Cap-fEWB&OAT", + "category": "PkgdTerminalAC", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "OAT", + "coeff_1": 3.2722656, + "coeff_2": -0.14984352, + "coeff_3": 0.00140292, + "coeff_4": 0.0047124, + "coeff_5": -0.000162, + "coeff_6": 0.000207, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 21.11111, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PTACHPACEIRFT", + "category": "DX Cooling Coil", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Twb", + "independent_variable_2": "Toadb", + "coeff_1": 0.342414409, + "coeff_2": 0.034885008, + "coeff_3": -0.0006237, + "coeff_4": 0.004977216, + "coeff_5": 0.000437951, + "coeff_6": -0.000728028, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 23.88889, + "minimum_independent_variable_2": 18.3, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From DOE Reference Buildings SmallHotel" + }, + { + "name": "Pump-Head-fFlow", + "category": "Pumps", + "form": "Quadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Flow", + "independent_variable_2": null, + "coeff_1": 1.3534831, + "coeff_2": 33.8, + "coeff_3": -1660000, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Pump-Power-fFlow", + "category": "Pumps", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "Flow", + "independent_variable_2": null, + "coeff_1": 0.3697739, + "coeff_2": 1780.65378, + "coeff_3": -943000, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PVV240to760_BF_fFlow", + "category": "BF_fFlow", + "form": "Linear", + "dependent_variable": null, + "independent_variable_1": "Flow", + "independent_variable_2": null, + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0, + "maximum_dependent_variable_output": 1, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PVV240to760_BF_fT", + "category": "BF_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 8.747712, + "coeff_2": -1.2544704, + "coeff_3": 0.034992, + "coeff_4": 0.219888, + "coeff_5": -0.00221292, + "coeff_6": -0.00284796, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0, + "maximum_dependent_variable_output": 3.2, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PVV240to760_CEIR_fPLR", + "category": "CEIR_fPLR", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.124, + "coeff_2": 0.376, + "coeff_3": 1.29, + "coeff_4": -0.794, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PVV240to760_ClCap_fT", + "category": "ClCap_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0.9521152, + "coeff_2": -0.01097712, + "coeff_3": 0.0012312, + "coeff_4": -0.00072792, + "coeff_5": -4.54e-05, + "coeff_6": -0.000173988, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PVV240to760_CLoss_fPLR", + "category": "CLoss_fPLR", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0, + "coeff_2": 1, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.1, + "maximum_dependent_variable_output": 1, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PVV240to760_ClSH_fT", + "category": "ClSH_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 1.91654848, + "coeff_2": 0.0047736, + "coeff_3": -0.00233604, + "coeff_4": -0.013756896, + "coeff_5": -3.23e-05, + "coeff_6": 0.00057672, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PVV240to760_EIR_fT", + "category": "EIR_fT", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0.380192, + "coeff_2": 0.0241488, + "coeff_3": -0.00047952, + "coeff_4": 0.0111168, + "coeff_5": 0.00052488, + "coeff_6": -0.00102384, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PVV240to760_HIR_fT", + "category": "HIR_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PVV240to760_HtCap_fT", + "category": "HtCap_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PVVT-Bypass-Factor-fAirflow", + "category": "PkgdVVVT", + "form": "Quadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Airflow", + "independent_variable_2": null, + "coeff_1": -0.254, + "coeff_2": 1.22, + "coeff_3": 0.036, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PVVT-Bypass-Factor-fEWB&EDB", + "category": "PkgdVVVT", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "EDB", + "coeff_1": 0.85028352, + "coeff_2": 0.014256792, + "coeff_3": 0.000184, + "coeff_4": -0.014791716, + "coeff_5": -5.48e-06, + "coeff_6": 0.000487, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 21.11111, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PVVT-Cool-Cap-fEWB&OAT", + "category": "PkgdVVVT", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "OAT", + "coeff_1": 0.86783424, + "coeff_2": 0.014239008, + "coeff_3": 0.000554, + "coeff_4": -0.007558056, + "coeff_5": 3.3e-05, + "coeff_6": -0.000192, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 21.11111, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PVVT-Cool-EIR-fEWB&OAT", + "category": "PkgdVVVT", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "OAT", + "coeff_1": 0.1210048, + "coeff_2": 0.0285336, + "coeff_3": -0.000411, + "coeff_4": 0.02134944, + "coeff_5": 0.000161, + "coeff_6": -0.00068, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 21.11111, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PVVT-Cool-EIR-fPLR", + "category": "PkgdVVVT", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.201, + "coeff_2": -0.0312, + "coeff_3": 1.9504979, + "coeff_4": -1.1205104, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PVVT-Heat-Cap-fEDB&OAT", + "category": "PkgdVVVT", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EDB", + "independent_variable_2": "OAT", + "coeff_1": 0.74200928, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0.030668544, + "coeff_5": 3.23e-05, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.33333, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PVVT-Heat-EIR-fEDB&OAT", + "category": "PkgdVVVT", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "EDB", + "independent_variable_2": "OAT", + "coeff_1": 1.255664, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": -0.0399528, + "coeff_5": 0.00108864, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.33333, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PVVT-Heat-EIR-fPLR", + "category": "PkgdVVVT", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.0857, + "coeff_2": 0.939, + "coeff_3": -0.183, + "coeff_4": 0.159, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "PVVT-Sens-Cap-fEWB&OAT", + "category": "PkgdVVVT", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "OAT", + "coeff_1": 2.93229888, + "coeff_2": -0.09445968, + "coeff_3": 0.0002, + "coeff_4": -0.007173756, + "coeff_5": 1.03e-05, + "coeff_6": 0.000109, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 21.11111, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Rcmp-kW-f-Tc-T1-Hi-Eff", + "category": "Refrigeration", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "Tc", + "independent_variable_2": null, + "coeff_1": 0.635620298, + "coeff_2": 0.003533521, + "coeff_3": 0.000161, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.7533, + "maximum_dependent_variable_output": 1.2802, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Rcmp-kW-f-Tc-T1-Low-Eff", + "category": "Refrigeration", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "Tc", + "independent_variable_2": null, + "coeff_1": 1.113461, + "coeff_2": -0.0308988, + "coeff_3": 0.000739, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.950084, + "maximum_dependent_variable_output": 1.606833, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Rcmp-kW-f-Tc-T2-Hi-Eff", + "category": "Refrigeration", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "Tc", + "independent_variable_2": null, + "coeff_1": 0.580834119, + "coeff_2": 0.00494838, + "coeff_3": 0.000161, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.7262, + "maximum_dependent_variable_output": 1.3046, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Rcmp-kW-f-Tc-T2-Low-Eff", + "category": "Refrigeration", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "Tc", + "independent_variable_2": null, + "coeff_1": 0.970164, + "coeff_2": -0.02268, + "coeff_3": 0.000625, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.943908, + "maximum_dependent_variable_output": 1.565353, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Rcmp-kW-f-Tc-T3-Hi-Eff", + "category": "Refrigeration", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "Tc", + "independent_variable_2": null, + "coeff_1": 0.358796196, + "coeff_2": 0.007319986, + "coeff_3": 0.000257, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.5728, + "maximum_dependent_variable_output": 1.4917, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Rcmp-kW-f-Tc-T3-Low-Eff", + "category": "Refrigeration", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "Tc", + "independent_variable_2": null, + "coeff_1": 0.656539, + "coeff_2": -0.0039924, + "coeff_3": 0.00035, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.941987, + "maximum_dependent_variable_output": 1.418136, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Rcmp-kW2-f-Tc-T1-Hi-Eff", + "category": "Refrigeration", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "Tc", + "independent_variable_2": null, + "coeff_1": 0.904478102, + "coeff_2": -0.008972199, + "coeff_3": 0.000303, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.8518, + "maximum_dependent_variable_output": 1.2802, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Rcmp-kW2-f-Tc-T1-Low-Eff", + "category": "Refrigeration", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "Tc", + "independent_variable_2": null, + "coeff_1": 1.113461, + "coeff_2": -0.0308988, + "coeff_3": 0.000739, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.950084, + "maximum_dependent_variable_output": 1.606833, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Rcmp-kW2-f-Tc-T2-Hi-Eff", + "category": "Refrigeration", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "Tc", + "independent_variable_2": null, + "coeff_1": 0.887325182, + "coeff_2": -0.009516488, + "coeff_3": 0.000328, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.8326, + "maximum_dependent_variable_output": 1.3046, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Rcmp-kW2-f-Tc-T2-Low-Eff", + "category": "Refrigeration", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "Tc", + "independent_variable_2": null, + "coeff_1": 0.970164, + "coeff_2": -0.02268, + "coeff_3": 0.000625, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.943908, + "maximum_dependent_variable_output": 1.565353, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Rcmp-kW2-f-Tc-T3-Hi-Eff", + "category": "Refrigeration", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "Tc", + "independent_variable_2": null, + "coeff_1": 0.829593266, + "coeff_2": -0.014865914, + "coeff_3": 0.000512, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.7434, + "maximum_dependent_variable_output": 1.4917, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Rcmp-kW2-f-Tc-T3-Low-Eff", + "category": "Refrigeration", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "Tc", + "independent_variable_2": null, + "coeff_1": 0.656539, + "coeff_2": -0.0039924, + "coeff_3": 0.00035, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.941987, + "maximum_dependent_variable_output": 1.418136, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Rcond-Fan-Pwr-fPLR-ACpress", + "category": "Refrigeration", + "form": "Linear", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0, + "coeff_2": 1, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0, + "maximum_dependent_variable_output": 1, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Rcond-Fan-Pwr-fPLR-Damper", + "category": "Refrigeration", + "form": "Linear", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.3, + "coeff_2": 0.7, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.3, + "maximum_dependent_variable_output": 1, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RecipAir-Cap-fCHWT&DBT", + "category": "HermReciprocatg", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "DBT", + "coeff_1": 1.10674018, + "coeff_2": 0.040197888, + "coeff_3": 0.000286, + "coeff_4": -0.009552852, + "coeff_5": 5.22e-06, + "coeff_6": -0.000255, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RecipAir-EIR-fCHWT&DBT", + "category": "HermReciprocatg", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "DBT", + "coeff_1": 0.53866251, + "coeff_2": -0.008142246, + "coeff_3": 0.000125, + "coeff_4": 0.011090538, + "coeff_5": 0.000164, + "coeff_6": -0.000342, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RecipAir-EIR-fPLR-1Comp/Ckt", + "category": "HermReciprocatg", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": "dT", + "coeff_1": 0.03892594, + "coeff_2": 1.07531738, + "coeff_3": -0.10724027, + "coeff_4": -0.001050714, + "coeff_5": 9.43e-06, + "coeff_6": 0.000536346, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RecipAir-EIR-fPLR-2Comp/Ckt", + "category": "HermReciprocatg", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": "dT", + "coeff_1": 0.04812248, + "coeff_2": 0.69573414, + "coeff_3": 0.2349389, + "coeff_4": 0.000819378, + "coeff_5": -3.86e-06, + "coeff_6": 3.79e-05, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RecipAir-EIR-fPLR-3Comp/Ckt", + "category": "HermReciprocatg", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": "dT", + "coeff_1": 0.03296722, + "coeff_2": 0.57721251, + "coeff_3": 0.33923307, + "coeff_4": 0.002786436, + "coeff_5": -3.11e-05, + "coeff_6": -0.000119, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RecipAir-EIR-fPLR-4Comp/Ckt", + "category": "HermReciprocatg", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": "dT", + "coeff_1": 0.00434876, + "coeff_2": 0.61917436, + "coeff_3": 0.32643354, + "coeff_4": 0.003223368, + "coeff_5": -3.33e-05, + "coeff_6": -0.000514206, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RecipH2O-Cap-fCHWT&ECT", + "category": "HermReciprocatg", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 1.0689798, + "coeff_2": 0.036781398, + "coeff_3": 0.000334, + "coeff_4": -0.010426122, + "coeff_5": 2.17e-05, + "coeff_6": -0.000208, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RecipH2O-EIR-fCHWT&ECT", + "category": "HermReciprocatg", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 0.51329254, + "coeff_2": -0.015039378, + "coeff_3": 0.000362, + "coeff_4": 0.015398694, + "coeff_5": 0.000228, + "coeff_6": -0.000409, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RecipH2O-EIR-fPLR&dT-1Comp/Ckt", + "category": "HermReciprocatg", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": "dT", + "coeff_1": -0.0142974, + "coeff_2": 0.95360994, + "coeff_3": 0.01805304, + "coeff_4": 0.002822994, + "coeff_5": -1.99e-05, + "coeff_6": -0.000497988, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RecipH2O-EIR-fPLR&dT-2Comp/Ckt", + "category": "HermReciprocatg", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": "dT", + "coeff_1": 0.02391765, + "coeff_2": 0.88946915, + "coeff_3": 0.07793053, + "coeff_4": -0.000474426, + "coeff_5": 2.33e-05, + "coeff_6": 0.000324, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RecipRemote-Cap-fCHWT&SCT", + "category": "HermReciprocatg", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "SCT", + "coeff_1": 1.27977199, + "coeff_2": 0.051393222, + "coeff_3": 0.000332, + "coeff_4": -0.009522792, + "coeff_5": -1.97e-05, + "coeff_6": -0.000269, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RecipRemote-EIR-fCHWT&SCT", + "category": "HermReciprocatg", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "SCT", + "coeff_1": 0.25314951, + "coeff_2": -0.015358788, + "coeff_3": 0.000506, + "coeff_4": 0.009717714, + "coeff_5": 0.000171, + "coeff_6": -0.000382, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RecipRemote-EIR-fPLR-1Comp/Ckt", + "category": "HermReciprocatg", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.03521065, + "coeff_2": 0.93266129, + "coeff_3": 0.03212802, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RecipRemote-EIR-fPLR-2Comp/Ckt", + "category": "HermReciprocatg", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.02511026, + "coeff_2": 0.8934145, + "coeff_3": 0.08147529, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Refg-Condenser-Cap-fCondT&WBT", + "category": "Refrigeration", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "CondT", + "independent_variable_2": "WBT", + "coeff_1": 0.15373327, + "coeff_2": 0.00942813, + "coeff_3": 0.000693, + "coeff_4": -0.020963196, + "coeff_5": -0.000702, + "coeff_6": 0.000302, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.2, + "maximum_dependent_variable_output": 2.222, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Refg-kW-fECT-T1", + "category": "Refrigeration", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "ECT", + "independent_variable_2": null, + "coeff_1": 0.753416, + "coeff_2": -0.0212148, + "coeff_3": 0.000739, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.850358, + "maximum_dependent_variable_output": 1.747334, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Refg-kW-fECT-T2", + "category": "Refrigeration", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "ECT", + "independent_variable_2": null, + "coeff_1": 1.00323, + "coeff_2": -0.0290574, + "coeff_3": 0.000765, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.859029, + "maximum_dependent_variable_output": 1.592964, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Refg-kW-fECT-T3", + "category": "Refrigeration", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "ECT", + "independent_variable_2": null, + "coeff_1": 0.671617, + "coeff_2": -0.0074358, + "coeff_3": 0.000424, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.873079, + "maximum_dependent_variable_output": 1.466883, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Refg-kW-fPLR", + "category": "Refrigeration", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.0383, + "coeff_2": 1.08, + "coeff_3": -0.116129, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.1, + "maximum_dependent_variable_output": 1.2, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Refg-kW2-fECT-T1", + "category": "Refrigeration", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "ECT", + "independent_variable_2": null, + "coeff_1": 0.753416, + "coeff_2": -0.0212148, + "coeff_3": 0.000739, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.850358, + "maximum_dependent_variable_output": 1.747334, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Refg-kW2-fECT-T2", + "category": "Refrigeration", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "ECT", + "independent_variable_2": null, + "coeff_1": 1.00323, + "coeff_2": -0.0290574, + "coeff_3": 0.000765, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.859029, + "maximum_dependent_variable_output": 1.592964, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Refg-kW2-fECT-T3", + "category": "Refrigeration", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "ECT", + "independent_variable_2": null, + "coeff_1": 0.671617, + "coeff_2": -0.0074358, + "coeff_3": 0.000424, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.873079, + "maximum_dependent_variable_output": 1.466883, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Residential Fix Vol-Fan EIR", + "category": "FanEIR-FPLR", + "form": "Linear", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Residential Var Vol-Fan EIR", + "category": "FanEIR-FPLR", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.000281, + "coeff_2": -0.0579, + "coeff_3": 0.586, + "coeff_4": 0.471, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RestaurantFastFood Kitchen_Case:1_WALKINFREEZERSingleShelfHorizontal_LatentEnergyMult", + "category": "Refrigerated Case", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.0236, + "coeff_2": 0.0006, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -35, + "maximum_independent_variable_1": 20, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Prototype Buildings" + }, + { + "name": "RestaurantFastFood Kitchen_Case:2_SELFCONTAINEDDISPLAYCASEMultiShelfVertical_LatentEnergyMult", + "category": "Refrigerated Case", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.026526281, + "coeff_2": 0.001078032, + "coeff_3": 6.02558e-05, + "coeff_4": 1.23732e-06, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -35, + "maximum_independent_variable_1": 20, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Prototype Buildings" + }, + { + "name": "RESVVT-Bypass-Factor-fAirflow", + "category": "ResidentialVVVT", + "form": "Quadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Airflow", + "independent_variable_2": null, + "coeff_1": -0.254, + "coeff_2": 1.22, + "coeff_3": 0.036, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESVVT-Bypass-Factor-fEWB&EDB", + "category": "ResidentialVVVT", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "EDB", + "coeff_1": 0.85086272, + "coeff_2": 0.014256792, + "coeff_3": 0.000184, + "coeff_4": -0.014759136, + "coeff_5": -5.48e-06, + "coeff_6": 0.000487, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 21.11111, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESVVT-Cool-Cap-fEWB&OAT", + "category": "ResidentialVVVT", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "OAT", + "coeff_1": 0.47523136, + "coeff_2": 0.04006368, + "coeff_3": 0.000226, + "coeff_4": -0.000847152, + "coeff_5": -7.32e-06, + "coeff_6": -0.000447, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 21.11111, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESVVT-Cool-Cap-fRPM&OAT", + "category": "ResidentialVVVT", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "RPM", + "independent_variable_2": "OAT", + "coeff_1": -686.394, + "coeff_2": -427.2546283, + "coeff_3": -66.38563967, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESVVT-Cool-CondFan-fPLR&OAT", + "category": "ResidentialVVVT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": "OAT", + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESVVT-Cool-CycleLoss-fPLR", + "category": "ResidentialVVVT", + "form": "Linear", + "dependent_variable": "QRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.7, + "coeff_2": 0.3, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESVVT-Cool-EIR-fEWB&OAT", + "category": "ResidentialVVVT", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "OAT", + "coeff_1": 0.63153792, + "coeff_2": -0.012168288, + "coeff_3": 0.000509, + "coeff_4": 0.015536304, + "coeff_5": 0.000273, + "coeff_6": -0.000679, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 21.11111, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESVVT-Cool-EIR-fPLR", + "category": "ResidentialVVVT", + "form": "Linear", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0, + "coeff_2": 1, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESVVT-Cool-EIR-fRPM&OAT", + "category": "ResidentialVVVT", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "RPM", + "independent_variable_2": "OAT", + "coeff_1": 35.1027, + "coeff_2": 10.50422626, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESVVT-Cool-EIR-LoSpeed-fEWB&OAT", + "category": "ResidentialVVVT", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "OAT", + "coeff_1": 0.77672128, + "coeff_2": -0.034271136, + "coeff_3": 0.000784, + "coeff_4": 0.01465956, + "coeff_5": 0.000489, + "coeff_6": -0.000752, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 21.11111, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESVVT-Cool-Waste-Heat-fEWB&OAT", + "category": "ResidentialVVVT", + "form": "BiLinear", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "OAT", + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESVVT-Cool-Waste-Heat-fRPM&OAT", + "category": "ResidentialVVVT", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "RPM", + "independent_variable_2": "OAT", + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESVVT-Heat-Cap-fEDB&OAT", + "category": "ResidentialVVVT", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EDB", + "independent_variable_2": "OAT", + "coeff_1": 0.7716, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0.02754, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.33333, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESVVT-Heat-Cap-fRPM&OAT", + "category": "ResidentialVVVT", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "RPM", + "independent_variable_2": "OAT", + "coeff_1": -483.189, + "coeff_2": -303.9732093, + "coeff_3": -47.69188125, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": -23.33333, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESVVT-Heat-CondFan-fPLR&OAT", + "category": "ResidentialVVVT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": "OAT", + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": -23.33333, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESVVT-Heat-CycleLoss-fPLR", + "category": "ResidentialVVVT", + "form": "Linear", + "dependent_variable": "QRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.75, + "coeff_2": 0.25, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESVVT-Heat-EIR-fEDB&OAT", + "category": "ResidentialVVVT", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "EDB", + "independent_variable_2": "OAT", + "coeff_1": 1.1544, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": -0.02448, + "coeff_5": 0.000729, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": -23.33333, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESVVT-Heat-EIR-fPLR", + "category": "ResidentialVVVT", + "form": "Linear", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0, + "coeff_2": 1, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESVVT-Heat-EIR-fRPM&OAT", + "category": "ResidentialVVVT", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "RPM", + "independent_variable_2": "OAT", + "coeff_1": 31.9068, + "coeff_2": 9.520648707, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": -23.33333, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESVVT-Heat-EIR-LoSpeed-fEDB&OAT", + "category": "ResidentialVVVT", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "EDB", + "independent_variable_2": "OAT", + "coeff_1": 1.25435136, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": -0.040685472, + "coeff_5": 0.001209784, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.33333, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESVVT-Heat-Waste-Heat-fEDB&OAT", + "category": "ResidentialVVVT", + "form": "BiLinear", + "dependent_variable": "QRatio", + "independent_variable_1": "EDB", + "independent_variable_2": "OAT", + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.33333, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESVVT-Heat-Waste-Heat-fRPM&OAT", + "category": "ResidentialVVVT", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "RPM", + "independent_variable_2": "OAT", + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": -23.33333, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESVVT-Sens-Cap-fEWB&OAT", + "category": "ResidentialVVVT", + "form": "BiLinear", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "OAT", + "coeff_1": 2.78672, + "coeff_2": -0.08208, + "coeff_3": -0.005292, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 21.11111, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESYS-Bypass-Factor-fAirflow", + "category": "Residential#1", + "form": "Quadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Airflow", + "independent_variable_2": null, + "coeff_1": -3.01, + "coeff_2": 6.59, + "coeff_3": -2.57, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESYS-Bypass-Factor-fEWB&EDB", + "category": "Residential#1", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "EDB", + "coeff_1": -1.1641344, + "coeff_2": 0.20453184, + "coeff_3": -0.000603, + "coeff_4": -0.03036096, + "coeff_5": 0.00036, + "coeff_6": -0.001464804, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 21.11111, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESYS-Bypass-Factor-fPLR", + "category": "ResidentialVVVT", + "form": "Linear", + "dependent_variable": "QRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESYS-Cool-Cap-fEWB&OAT", + "category": "Residential#1", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "OAT", + "coeff_1": 0.7665024, + "coeff_2": 0.01076904, + "coeff_3": -4.15e-05, + "coeff_4": 0.00133848, + "coeff_5": -0.000261, + "coeff_6": 0.000457, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 21.11111, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESYS-Cool-EIR-fEWB&OAT", + "category": "Residential#1", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "OAT", + "coeff_1": 0.29770688, + "coeff_2": 0.04314528, + "coeff_3": -0.000748, + "coeff_4": 0.005972688, + "coeff_5": 0.000482, + "coeff_6": -0.000956, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 21.11111, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESYS-Cool-EIR-fPLR", + "category": null, + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 6.26e-05, + "coeff_2": 1.18, + "coeff_3": -0.202, + "coeff_4": 0.0263344, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESYS-Heat-Cap-fEDB&OAT", + "category": "Residential#1", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EDB", + "independent_variable_2": "OAT", + "coeff_1": 0.7516064, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0.02799072, + "coeff_5": 0.00019, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.33333, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESYS-Heat-EIR-fEDB&OAT", + "category": "Residential#1", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "EDB", + "independent_variable_2": "OAT", + "coeff_1": 1.231072, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": -0.0334944, + "coeff_5": 0.000739, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.33333, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESYS-Heat-EIR-fPLR", + "category": "Residential#1", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.0857, + "coeff_2": 0.939, + "coeff_3": -0.1834361, + "coeff_4": 0.15897022, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESYS-Sens-Cap-fAirflow", + "category": "Residential#1", + "form": "Linear", + "dependent_variable": "QRatio", + "independent_variable_1": "Airflow", + "independent_variable_2": null, + "coeff_1": 0.6, + "coeff_2": 0.4, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "RESYS-Sens-Cap-fEWB&OAT", + "category": "Residential#1", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "OAT", + "coeff_1": 3.3127968, + "coeff_2": -0.1617552, + "coeff_3": 0.00184356, + "coeff_4": 0.01027584, + "coeff_5": -0.000156, + "coeff_6": -2.84e-05, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 21.11111, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SAC Heating Coil PLF-FPLR", + "category": "DX Heating Coil", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.8, + "coeff_2": 0.2, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Prototype Buildings" + }, + { + "name": "SchoolPrimary Kitchen_ZN_1_FLR_1_Case:1_WALKINFREEZERSingleShelfHorizontal_LatentEnergyMult", + "category": "Refrigerated Case", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.0236, + "coeff_2": 0.0006, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -35, + "maximum_independent_variable_1": 20, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Prototype Buildings" + }, + { + "name": "SchoolPrimary Kitchen_ZN_1_FLR_1_Case:2_SELFCONTAINEDDISPLAYCASEMultiShelfVertical_LatentEnergyMult", + "category": "Refrigerated Case", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.026526281, + "coeff_2": 0.001078032, + "coeff_3": 6.02558e-05, + "coeff_4": 1.23732e-06, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -35, + "maximum_independent_variable_1": 20, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Prototype Buildings" + }, + { + "name": "ScrewAir-Cap-fCHWT&DBT", + "category": "Screw", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "DBT", + "coeff_1": 0.97878647, + "coeff_2": 0.02387169, + "coeff_3": 0.000587, + "coeff_4": -4.78e-05, + "coeff_5": -0.000112, + "coeff_6": -0.00011, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ScrewAir-EIR-fCHWT&DBT", + "category": "Screw", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "DBT", + "coeff_1": 0.6729704, + "coeff_2": -0.005730012, + "coeff_3": 0.000702, + "coeff_4": -0.00119601, + "coeff_5": 0.00044, + "coeff_6": -0.000699, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ScrewAir-EIR-fPLR&dT-1Comp/Ckt", + "category": "Screw", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": "dT", + "coeff_1": 0.01040687, + "coeff_2": 1.05183303, + "coeff_3": -0.09462459, + "coeff_4": 0.002943774, + "coeff_5": -2.52e-05, + "coeff_6": -0.001085832, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ScrewAir-EIR-fPLR&dT-2Comp/Ckt", + "category": "Screw", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": "dT", + "coeff_1": 0.09611014, + "coeff_2": 0.72898877, + "coeff_3": 0.19517007, + "coeff_4": -0.000729072, + "coeff_5": 6.67e-06, + "coeff_6": -0.000175, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ScrewH2O-Cap-fCHWT&ECT", + "category": "Screw", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 1.07096667, + "coeff_2": 0.02693502, + "coeff_3": 0.000768, + "coeff_4": -0.00643302, + "coeff_5": -9.49e-05, + "coeff_6": -6.59e-05, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ScrewH2O-EIR-fCHWT&ECT", + "category": "Screw", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "ECT", + "coeff_1": 0.59849788, + "coeff_2": -0.00123345, + "coeff_3": 0.000563, + "coeff_4": 0.001602738, + "coeff_5": 0.000636, + "coeff_6": -0.001094148, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ScrewH2O-EIR-fPLR&dT-1Comp/Ckt", + "category": "Screw", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": "dT", + "coeff_1": -0.11699212, + "coeff_2": 1.2635448, + "coeff_3": -0.2194667, + "coeff_4": 0.005301648, + "coeff_5": 5.47e-05, + "coeff_6": -0.003346506, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ScrewH2O-EIR-fPLR&dT-2Comp/Ckt", + "category": "Screw", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": "dT", + "coeff_1": -0.27111483, + "coeff_2": 1.49009538, + "coeff_3": -0.33198115, + "coeff_4": 0.017556084, + "coeff_5": -0.000191, + "coeff_6": -0.008247186, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ScrewRemote-Cap-fCHWT&SCT", + "category": "Screw", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "SCT", + "coeff_1": 1.16410009, + "coeff_2": 0.048370122, + "coeff_3": 0.000493, + "coeff_4": -0.002428218, + "coeff_5": -0.000109, + "coeff_6": -0.000269, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ScrewRemote-EIR-fCHWT&SCT", + "category": "Screw", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "SCT", + "coeff_1": 0.79518287, + "coeff_2": -0.009101466, + "coeff_3": 0.001707804, + "coeff_4": -0.015352632, + "coeff_5": 0.000488, + "coeff_6": -0.000932, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ScrewRemote-EIR-fPLR-1Comp/Ckt", + "category": "Screw", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.07043035, + "coeff_2": 1.01683199, + "coeff_3": -0.08726242, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ScrewRemote-EIR-fPLR-2Comp/Ckt", + "category": "Screw", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.08138224, + "coeff_2": 0.72724819, + "coeff_3": 0.19136968, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ScrollChlrAirCoolCap-fCHW&OAT", + "category": "Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "OAT", + "coeff_1": 1.05229229, + "coeff_2": 0.033560892, + "coeff_3": 0.000215, + "coeff_4": -0.005180832, + "coeff_5": -4.42e-05, + "coeff_6": -0.000215, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ScrollChlrAirCoolEIR-fCHW&OAT", + "category": "Chiller", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "CHWT", + "independent_variable_2": "OAT", + "coeff_1": 0.58333562, + "coeff_2": -0.004036194, + "coeff_3": 0.000468, + "coeff_4": -0.000224478, + "coeff_5": 0.000481, + "coeff_6": -0.000682, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "ScrollChlrAirCoolEIR-fPLR", + "category": "Chiller", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.03366649, + "coeff_2": 0.53152555, + "coeff_3": 0.43480802, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Si-Film_Spectral-fAirMass", + "category": "PV-Module", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": "AirMass", + "independent_variable_2": null, + "coeff_1": 0.95691782, + "coeff_2": 0.04079713, + "coeff_3": -0.00869376, + "coeff_4": 0.00042887, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Single Shelf Horizontal Latent Energy Multiplier_After2004", + "category": "Refrigerated Case", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.0236, + "coeff_2": 0.0006, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -35, + "maximum_independent_variable_1": 20, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Reference Buildings" + }, + { + "name": "Single Shelf Horizontal Latent Energy Multiplier_Pre2004", + "category": "Refrigerated Case", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.020376, + "coeff_2": 0.00024378, + "coeff_3": 1.14e-05, + "coeff_4": 1.811e-07, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -35, + "maximum_independent_variable_1": 20, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Reference Buildings" + }, + { + "name": "Single zone VAV fan", + "category": "FanEIR-FPLR", + "form": "Cubic", + "dependent_variable": "PwrRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.027827882, + "coeff_2": 0.026583195, + "coeff_3": -0.0870687, + "coeff_4": 1.03091975, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.1, + "maximum_dependent_variable_output": null, + "annotation": "Baseline for System Type 11 from ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method" + }, + { + "name": "Small-CHW-Bypass-fAirflow", + "category": "CHWCoils", + "form": "Quadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Airflow", + "independent_variable_2": null, + "coeff_1": -0.718, + "coeff_2": 1.91, + "coeff_3": -0.189, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Small-CHW-Coil-Bypass-fEWB&EDB", + "category": "CHWCoils", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "EDB", + "coeff_1": 1.09657216, + "coeff_2": 0.001908, + "coeff_3": 0.000369, + "coeff_4": -0.005647032, + "coeff_5": 2.46e-05, + "coeff_6": -0.000277, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 15.55556, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Small-CHW-Coil-Cap-fEWB&EDB", + "category": "CHWCoils", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "EDB", + "coeff_1": -0.282048, + "coeff_2": -0.022212, + "coeff_3": 0.0054432, + "coeff_4": 0.0297216, + "coeff_5": 0.000804, + "coeff_6": -0.0033372, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 15.55556, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Small-CHW-Sens-Cap-fAirflow", + "category": "CHWCoils", + "form": "Quadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Airflow", + "independent_variable_2": null, + "coeff_1": 0.155, + "coeff_2": 1.01, + "coeff_3": -0.16, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Small-CHW-Sens-Cap-fEWB&EDB", + "category": "CHWCoils", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "EDB", + "coeff_1": -0.415152, + "coeff_2": -0.0405576, + "coeff_3": 0.00140616, + "coeff_4": 0.086508, + "coeff_5": 0.000444, + "coeff_6": -0.00184356, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 29.44444, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Smooth_Optical-fAOI", + "category": "PV-Module", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": "AOI", + "independent_variable_2": null, + "coeff_1": 3.76248479, + "coeff_2": -0.15946805, + "coeff_3": 0.00302191, + "coeff_4": -1.91e-05, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Split DX Coil EIR-FF", + "category": "DX Cooling Coil", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 1.1552, + "coeff_2": -0.1808, + "coeff_3": 0.0256, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.5, + "maximum_independent_variable_1": 1.5, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From PNNL Prototype Buildings ApartmentMidRise, HotelSmall, Warehouse" + }, + { + "name": "SpltAC1Sp_BF_fFlow", + "category": "BF_fFlow", + "form": "Linear", + "dependent_variable": null, + "independent_variable_1": "Flow", + "independent_variable_2": null, + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0, + "maximum_dependent_variable_output": 1, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp_BF_fT", + "category": "BF_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 8.513632, + "coeff_2": -0.630072, + "coeff_3": 0.0165888, + "coeff_4": -0.0450144, + "coeff_5": 0.00107892, + "coeff_6": -0.0018954, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0, + "maximum_dependent_variable_output": 3.33, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp_CEIR_fPLR_Hot", + "category": "CEIR_fPLR_Hot", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 7e-05, + "coeff_2": 1.23, + "coeff_3": -0.307, + "coeff_4": 0.0756, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp_CEIR_fPLR_Mod", + "category": "CEIR_fPLR_Mod", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.00012, + "coeff_2": 1.2, + "coeff_3": -0.261, + "coeff_4": 0.0596, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp_CEIR_fPLR_Tem", + "category": "CEIR_fPLR_Tem", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": -7e-05, + "coeff_2": 1.17, + "coeff_3": -0.213, + "coeff_4": 0.0438, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp_ClCap_fT", + "category": "ClCap_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0.67916, + "coeff_2": 0.016938, + "coeff_3": 0.00069336, + "coeff_4": 0.0045576, + "coeff_5": -8.42e-05, + "coeff_6": -0.00047628, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp_CLoss_fPLR_Hot", + "category": "CLoss_fPLR_Hot", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.805, + "coeff_2": 0.233, + "coeff_3": -0.038, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp_CLoss_fPLR_Mod", + "category": "CLoss_fPLR_Mod", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.827, + "coeff_2": 0.203, + "coeff_3": -0.03, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp_CLoss_fPLR_Tem", + "category": "CLoss_fPLR_Tem", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.852, + "coeff_2": 0.17, + "coeff_3": -0.0219, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp_ClSH_fT", + "category": "ClSH_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 2.7311616, + "coeff_2": -0.10297296, + "coeff_3": 0.00093636, + "coeff_4": 0.00477864, + "coeff_5": -9.07e-05, + "coeff_6": -0.000202824, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp_EIR_fT", + "category": "EIR_fT", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0.7390464, + "coeff_2": -0.00778968, + "coeff_3": 0.000128304, + "coeff_4": -0.00027, + "coeff_5": 0.0006642, + "coeff_6": -0.000648, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp_HIR_fT", + "category": "HIR_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp_HtCap_fT", + "category": "HtCap_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp-ge45_BF_fFlow", + "category": "BF_fFlow", + "form": "Linear", + "dependent_variable": null, + "independent_variable_1": "Flow", + "independent_variable_2": null, + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0, + "maximum_dependent_variable_output": 1, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp-ge45_BF_fT", + "category": "BF_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 16.900064, + "coeff_2": -1.747584, + "coeff_3": 0.050544, + "coeff_4": 0.1428912, + "coeff_5": 0.00048924, + "coeff_6": -0.0090396, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0, + "maximum_dependent_variable_output": 3.76, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp-ge45_CEIR_fPLR_Hot", + "category": "CEIR_fPLR_Hot", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0, + "coeff_2": 1.18, + "coeff_3": -0.223, + "coeff_4": 0.0468, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp-ge45_CEIR_fPLR_Mod", + "category": "CEIR_fPLR_Mod", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 8e-05, + "coeff_2": 1.15, + "coeff_3": -0.183, + "coeff_4": 0.0343, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp-ge45_CEIR_fPLR_Tem", + "category": "CEIR_fPLR_Tem", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": -0.0001, + "coeff_2": 1.12, + "coeff_3": -0.14, + "coeff_4": 0.0225, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp-ge45_ClCap_fT", + "category": "ClCap_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 1.2403136, + "coeff_2": -0.0346752, + "coeff_3": 0.00187596, + "coeff_4": 0.00106848, + "coeff_5": -5.7e-05, + "coeff_6": -0.0003564, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp-ge45_CLoss_fPLR_Hot", + "category": "CLoss_fPLR_Hot", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.847, + "coeff_2": 0.177, + "coeff_3": -0.0235, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp-ge45_CLoss_fPLR_Mod", + "category": "CLoss_fPLR_Mod", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.869, + "coeff_2": 0.149, + "coeff_3": -0.0172, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp-ge45_CLoss_fPLR_Tem", + "category": "CLoss_fPLR_Tem", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.893, + "coeff_2": 0.118, + "coeff_3": -0.0112, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp-ge45_ClSH_fT", + "category": "ClSH_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 1.8260768, + "coeff_2": 0.0199944, + "coeff_3": -0.00284148, + "coeff_4": -0.01422576, + "coeff_5": -5.77e-05, + "coeff_6": 0.00064152, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp-ge45_EIR_fT", + "category": "EIR_fT", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0.093776, + "coeff_2": 0.0674784, + "coeff_3": -0.00192132, + "coeff_4": -0.0031176, + "coeff_5": 0.00067068, + "coeff_6": -0.0005832, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp-ge45_HIR_fT", + "category": "HIR_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp-ge45_HtCap_fT", + "category": "HtCap_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp-lt45_BF_fFlow", + "category": "BF_fFlow", + "form": "Linear", + "dependent_variable": null, + "independent_variable_1": "Flow", + "independent_variable_2": null, + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0, + "maximum_dependent_variable_output": 1, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp-lt45_BF_fT", + "category": "BF_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 22.932224, + "coeff_2": -2.291616, + "coeff_3": 0.063504, + "coeff_4": 0.0800712, + "coeff_5": 0.00076464, + "coeff_6": -0.0068364, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0, + "maximum_dependent_variable_output": 3.3, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp-lt45_CEIR_fPLR_Hot", + "category": "CEIR_fPLR_Hot", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0, + "coeff_2": 1.18, + "coeff_3": -0.223, + "coeff_4": 0.0468, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp-lt45_CEIR_fPLR_Mod", + "category": "CEIR_fPLR_Mod", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 8e-05, + "coeff_2": 1.15, + "coeff_3": -0.183, + "coeff_4": 0.0343, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp-lt45_CEIR_fPLR_Tem", + "category": "CEIR_fPLR_Tem", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": -0.0001, + "coeff_2": 1.12, + "coeff_3": -0.14, + "coeff_4": 0.0225, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp-lt45_ClCap_fT", + "category": "ClCap_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 1.1299744, + "coeff_2": -0.0222336, + "coeff_3": 0.0015228, + "coeff_4": -3.53e-05, + "coeff_5": -4.34e-05, + "coeff_6": -0.00032724, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp-lt45_CLoss_fPLR_Hot", + "category": "CLoss_fPLR_Hot", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.847, + "coeff_2": 0.177, + "coeff_3": -0.0235, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp-lt45_CLoss_fPLR_Mod", + "category": "CLoss_fPLR_Mod", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.869, + "coeff_2": 0.149, + "coeff_3": -0.0172, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp-lt45_CLoss_fPLR_Tem", + "category": "CLoss_fPLR_Tem", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.893, + "coeff_2": 0.118, + "coeff_3": -0.0112, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp-lt45_ClSH_fT", + "category": "ClSH_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 1.4985024, + "coeff_2": 0.0478512, + "coeff_3": -0.0034992, + "coeff_4": -0.01084968, + "coeff_5": -5.48e-05, + "coeff_6": 0.00047628, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp-lt45_EIR_fT", + "category": "EIR_fT", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0.09712, + "coeff_2": 0.0536256, + "coeff_3": -0.00144828, + "coeff_4": 0.0040644, + "coeff_5": 0.00062208, + "coeff_6": -0.000729, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp-lt45_HIR_fT", + "category": "HIR_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC1Sp-lt45_HtCap_fT", + "category": "HtCap_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC2SpHiSEER_BF_fFlow", + "category": "BF_fFlow", + "form": "Linear", + "dependent_variable": null, + "independent_variable_1": "Flow", + "independent_variable_2": null, + "coeff_1": 1.75, + "coeff_2": -1578.5656, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 1, + "maximum_dependent_variable_output": 1.189, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC2SpHiSEER_BF_fT", + "category": "BF_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 20.03024, + "coeff_2": -1.922832, + "coeff_3": 0.051516, + "coeff_4": 0.086184, + "coeff_5": 0.0011502, + "coeff_6": -0.0076788, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0, + "maximum_dependent_variable_output": 3.92, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC2SpHiSEER_CEIR_fPLR_Hot", + "category": "CEIR_fPLR_Hot", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.00635, + "coeff_2": 1.12, + "coeff_3": -0.139, + "coeff_4": 0.016, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC2SpHiSEER_CEIR_fPLR_Mod", + "category": "CEIR_fPLR_Mod", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": -0.00144, + "coeff_2": 1.12, + "coeff_3": -0.14, + "coeff_4": 0.022, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC2SpHiSEER_CEIR_fPLR_Tem", + "category": "CEIR_fPLR_Tem", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": -0.00726, + "coeff_2": 1.11, + "coeff_3": -0.132, + "coeff_4": 0.0262, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC2SpHiSEER_ClCap_fT", + "category": "ClCap_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 1.5240096, + "coeff_2": -0.0665928, + "coeff_3": 0.00299376, + "coeff_4": 0.00162288, + "coeff_5": -6.51e-05, + "coeff_6": -0.00048924, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC2SpHiSEER_CLoss_fPLR_Hot", + "category": "CLoss_fPLR_Hot", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.923, + "coeff_2": 0.153, + "coeff_3": -0.0156, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC2SpHiSEER_CLoss_fPLR_Mod", + "category": "CLoss_fPLR_Mod", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.94, + "coeff_2": 0.124, + "coeff_3": -0.0109, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC2SpHiSEER_CLoss_fPLR_Tem", + "category": "CLoss_fPLR_Tem", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.959, + "coeff_2": 0.0934, + "coeff_3": -0.00688, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC2SpHiSEER_ClSH_fT", + "category": "ClSH_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 1.54, + "coeff_2": 0.0382752, + "coeff_3": -0.00297756, + "coeff_4": -0.0114912, + "coeff_5": -0.00010044, + "coeff_6": 0.0005346, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC2SpHiSEER_EIR_fT", + "category": "EIR_fT", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": -0.172512, + "coeff_2": 0.1176624, + "coeff_3": -0.00324, + "coeff_4": -0.01152, + "coeff_5": 0.00077112, + "coeff_6": -0.00057024, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC2SpHiSEER_HIR_fT", + "category": "HIR_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC2SpHiSEER_HtCap_fT", + "category": "HtCap_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC2SpLoSEER_BF_fFlow", + "category": "BF_fFlow", + "form": "Linear", + "dependent_variable": null, + "independent_variable_1": "Flow", + "independent_variable_2": null, + "coeff_1": 1.75, + "coeff_2": -1578.5656, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 1, + "maximum_dependent_variable_output": 1.189, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC2SpLoSEER_BF_fT", + "category": "BF_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 10.820416, + "coeff_2": -1.041264, + "coeff_3": 0.0254988, + "coeff_4": 0.2290608, + "coeff_5": 0.00062856, + "coeff_6": -0.0117612, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0, + "maximum_dependent_variable_output": 5.76, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC2SpLoSEER_CEIR_fPLR_Hot", + "category": "CEIR_fPLR_Hot", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": -0.00016, + "coeff_2": 1.12, + "coeff_3": -0.143, + "coeff_4": 0.0206, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC2SpLoSEER_CEIR_fPLR_Mod", + "category": "CEIR_fPLR_Mod", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": -0.00146, + "coeff_2": 1.1, + "coeff_3": -0.119, + "coeff_4": 0.0176, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC2SpLoSEER_CEIR_fPLR_Tem", + "category": "CEIR_fPLR_Tem", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.00284, + "coeff_2": 1.06, + "coeff_3": -0.0687, + "coeff_4": 0.00523, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC2SpLoSEER_ClCap_fT", + "category": "ClCap_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 1.54887488, + "coeff_2": -0.0648072, + "coeff_3": 0.00310068, + "coeff_4": -0.000425376, + "coeff_5": -2.55e-05, + "coeff_6": -0.00060264, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC2SpLoSEER_CLoss_fPLR_Hot", + "category": "CLoss_fPLR_Hot", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.856, + "coeff_2": 0.121, + "coeff_3": -0.0124, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC2SpLoSEER_CLoss_fPLR_Mod", + "category": "CLoss_fPLR_Mod", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.872, + "coeff_2": 0.0941, + "coeff_3": -0.00752, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC2SpLoSEER_CLoss_fPLR_Tem", + "category": "CLoss_fPLR_Tem", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.889, + "coeff_2": 0.0695, + "coeff_3": -0.00646, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC2SpLoSEER_ClSH_fT", + "category": "ClSH_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 2.322048, + "coeff_2": -0.0286956, + "coeff_3": -0.00124092, + "coeff_4": -0.020124, + "coeff_5": -4.05e-05, + "coeff_6": 0.0006804, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC2SpLoSEER_EIR_fT", + "category": "EIR_fT", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": -0.281376, + "coeff_2": 0.1343088, + "coeff_3": -0.0036936, + "coeff_4": -0.0173736, + "coeff_5": 0.00096552, + "coeff_6": -0.00075168, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC2SpLoSEER_HIR_fT", + "category": "HIR_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltAC2SpLoSEER_HtCap_fT", + "category": "HtCap_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltACEvap_BF_fFlow", + "category": "BF_fFlow", + "form": "Linear", + "dependent_variable": null, + "independent_variable_1": "Flow", + "independent_variable_2": null, + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0, + "maximum_dependent_variable_output": 1, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltACEvap_BF_fT", + "category": "BF_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 16.06, + "coeff_2": -1.566, + "coeff_3": 0.0405, + "coeff_4": 1.75e-10, + "coeff_5": 3.24e-12, + "coeff_6": 3.24e-12, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0, + "maximum_dependent_variable_output": 3.97, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltACEvap_CEIR_fPLR_Hot", + "category": "CEIR_fPLR_Hot", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0, + "coeff_2": 1, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltACEvap_CEIR_fPLR_Mod", + "category": "CEIR_fPLR_Mod", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0, + "coeff_2": 1, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltACEvap_CEIR_fPLR_Tem", + "category": "CEIR_fPLR_Tem", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0, + "coeff_2": 1, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltACEvap_ClCap_fT", + "category": "ClCap_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0.6302064, + "coeff_2": 0.0171576, + "coeff_3": 0.00069012, + "coeff_4": -0.00374688, + "coeff_5": 0.000212544, + "coeff_6": -0.0005508, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltACEvap_CLoss_fPLR_Hot", + "category": "CLoss_fPLR_Hot", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.94, + "coeff_2": 0.06, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltACEvap_CLoss_fPLR_Mod", + "category": "CLoss_fPLR_Mod", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.97, + "coeff_2": 0.03, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltACEvap_CLoss_fPLR_Tem", + "category": "CLoss_fPLR_Tem", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltACEvap_ClSH_fT", + "category": "ClSH_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 1.9516064, + "coeff_2": -0.0154008, + "coeff_3": -0.0012798, + "coeff_4": -0.00110088, + "coeff_5": 0.000194724, + "coeff_6": -0.00054432, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltACEvap_EIR_fT", + "category": "EIR_fT", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 1.207232, + "coeff_2": -0.0528552, + "coeff_3": 0.00053136, + "coeff_4": 0.0261288, + "coeff_5": -0.00045684, + "coeff_6": 0.0005508, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltACEvap_HIR_fT", + "category": "HIR_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltACEvap_HtCap_fT", + "category": "HtCap_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0, + "coeff_5": 0, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP1SpCom_BF_fFlow", + "category": "BF_fFlow", + "form": "Linear", + "dependent_variable": null, + "independent_variable_1": "Flow", + "independent_variable_2": null, + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0, + "maximum_dependent_variable_output": 1, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP1SpCom_BF_fT", + "category": "BF_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 8.513632, + "coeff_2": -0.630072, + "coeff_3": 0.0165888, + "coeff_4": -0.0450144, + "coeff_5": 0.00107892, + "coeff_6": -0.0018954, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0, + "maximum_dependent_variable_output": 3.33, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP1SpCom_CEIR_fPLR_Hot", + "category": "CEIR_fPLR_Hot", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 7e-05, + "coeff_2": 1.23, + "coeff_3": -0.307, + "coeff_4": 0.0756, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP1SpCom_CEIR_fPLR_Mod", + "category": "CEIR_fPLR_Mod", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.00012, + "coeff_2": 1.2, + "coeff_3": -0.261, + "coeff_4": 0.0596, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP1SpCom_CEIR_fPLR_Tem", + "category": "CEIR_fPLR_Tem", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": -7e-05, + "coeff_2": 1.17, + "coeff_3": -0.213, + "coeff_4": 0.0438, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP1SpCom_ClCap_fT", + "category": "ClCap_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0.67916, + "coeff_2": 0.016938, + "coeff_3": 0.00069336, + "coeff_4": 0.0045576, + "coeff_5": -8.42e-05, + "coeff_6": -0.00047628, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP1SpCom_CLoss_fPLR_Hot", + "category": "CLoss_fPLR_Hot", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.805, + "coeff_2": 0.233, + "coeff_3": -0.038, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP1SpCom_CLoss_fPLR_Mod", + "category": "CLoss_fPLR_Mod", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.827, + "coeff_2": 0.203, + "coeff_3": -0.03, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP1SpCom_CLoss_fPLR_Tem", + "category": "CLoss_fPLR_Tem", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.852, + "coeff_2": 0.17, + "coeff_3": -0.0219, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP1SpCom_ClSH_fT", + "category": "ClSH_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 2.7311616, + "coeff_2": -0.10297296, + "coeff_3": 0.00093636, + "coeff_4": 0.00477864, + "coeff_5": -9.07e-05, + "coeff_6": -0.000202824, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP1SpCom_EIR_fT", + "category": "EIR_fT", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0.7390464, + "coeff_2": -0.00778968, + "coeff_3": 0.000128304, + "coeff_4": -0.00027, + "coeff_5": 0.0006642, + "coeff_6": -0.000648, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP1SpCom_HIR_fT", + "category": "HIR_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0.8186976, + "coeff_2": 0.01406952, + "coeff_3": 0.000117936, + "coeff_4": -0.01579104, + "coeff_5": 0.000222264, + "coeff_6": -0.000300024, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP1SpCom_HtCap_fT", + "category": "HtCap_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0.85516576, + "coeff_2": -0.003631392, + "coeff_3": -6.19e-06, + "coeff_4": 0.02644704, + "coeff_5": 0.00041148, + "coeff_6": -0.000141264, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP1SpRes_BF_fFlow", + "category": "BF_fFlow", + "form": "Linear", + "dependent_variable": null, + "independent_variable_1": "Flow", + "independent_variable_2": null, + "coeff_1": 1, + "coeff_2": 0, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0, + "maximum_dependent_variable_output": 1, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP1SpRes_BF_fT", + "category": "BF_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 8.513632, + "coeff_2": -0.630072, + "coeff_3": 0.0165888, + "coeff_4": -0.0450144, + "coeff_5": 0.00107892, + "coeff_6": -0.0018954, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0, + "maximum_dependent_variable_output": 3.33, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP1SpRes_CEIR_fPLR_Hot", + "category": "CEIR_fPLR_Hot", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 7e-05, + "coeff_2": 1.23, + "coeff_3": -0.307, + "coeff_4": 0.0756, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP1SpRes_CEIR_fPLR_Mod", + "category": "CEIR_fPLR_Mod", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.00012, + "coeff_2": 1.2, + "coeff_3": -0.261, + "coeff_4": 0.0596, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP1SpRes_CEIR_fPLR_Tem", + "category": "CEIR_fPLR_Tem", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": -7e-05, + "coeff_2": 1.17, + "coeff_3": -0.213, + "coeff_4": 0.0438, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP1SpRes_ClCap_fT", + "category": "ClCap_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0.67916, + "coeff_2": 0.016938, + "coeff_3": 0.00069336, + "coeff_4": 0.0045576, + "coeff_5": -8.42e-05, + "coeff_6": -0.00047628, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP1SpRes_CLoss_fPLR_Hot", + "category": "CLoss_fPLR_Hot", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.805, + "coeff_2": 0.233, + "coeff_3": -0.038, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP1SpRes_CLoss_fPLR_Mod", + "category": "CLoss_fPLR_Mod", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.827, + "coeff_2": 0.203, + "coeff_3": -0.03, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP1SpRes_CLoss_fPLR_Tem", + "category": "CLoss_fPLR_Tem", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.852, + "coeff_2": 0.17, + "coeff_3": -0.0219, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP1SpRes_ClSH_fT", + "category": "ClSH_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 2.7311616, + "coeff_2": -0.10297296, + "coeff_3": 0.00093636, + "coeff_4": 0.00477864, + "coeff_5": -9.07e-05, + "coeff_6": -0.000202824, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP1SpRes_EIR_fT", + "category": "EIR_fT", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0.7390464, + "coeff_2": -0.00778968, + "coeff_3": 0.000128304, + "coeff_4": -0.00027, + "coeff_5": 0.0006642, + "coeff_6": -0.000648, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP1SpRes_HIR_fT", + "category": "HIR_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0.9003872, + "coeff_2": 0.01108728, + "coeff_3": 0.0001701, + "coeff_4": -0.02579472, + "coeff_5": 0.0008424, + "coeff_6": -0.000290628, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP1SpRes_HtCap_fT", + "category": "HtCap_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0.9303344, + "coeff_2": -0.0064656, + "coeff_3": 1.77e-05, + "coeff_4": 0.02813472, + "coeff_5": -5.51e-06, + "coeff_6": -0.000208656, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP2Sp_BF_fFlow", + "category": "BF_fFlow", + "form": "Linear", + "dependent_variable": null, + "independent_variable_1": "Flow", + "independent_variable_2": null, + "coeff_1": 1.75, + "coeff_2": -1578.5656, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 1, + "maximum_dependent_variable_output": 1.189, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP2Sp_BF_fT", + "category": "BF_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 20.03024, + "coeff_2": -1.922832, + "coeff_3": 0.051516, + "coeff_4": 0.086184, + "coeff_5": 0.0011502, + "coeff_6": -0.0076788, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0, + "maximum_dependent_variable_output": 3.92, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP2Sp_CEIR_fPLR_Hot", + "category": "CEIR_fPLR_Hot", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.00635, + "coeff_2": 1.12, + "coeff_3": -0.139, + "coeff_4": 0.016, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP2Sp_CEIR_fPLR_Mod", + "category": "CEIR_fPLR_Mod", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": -0.00144, + "coeff_2": 1.12, + "coeff_3": -0.14, + "coeff_4": 0.022, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP2Sp_CEIR_fPLR_Tem", + "category": "CEIR_fPLR_Tem", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": -0.00726, + "coeff_2": 1.11, + "coeff_3": -0.132, + "coeff_4": 0.0262, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP2Sp_ClCap_fT", + "category": "ClCap_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 1.5240096, + "coeff_2": -0.0665928, + "coeff_3": 0.00299376, + "coeff_4": 0.00162288, + "coeff_5": -6.51e-05, + "coeff_6": -0.00048924, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP2Sp_CLoss_fPLR_Hot", + "category": "CLoss_fPLR_Hot", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.923, + "coeff_2": 0.153, + "coeff_3": -0.0156, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP2Sp_CLoss_fPLR_Mod", + "category": "CLoss_fPLR_Mod", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.94, + "coeff_2": 0.124, + "coeff_3": -0.0109, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP2Sp_CLoss_fPLR_Tem", + "category": "CLoss_fPLR_Tem", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.959, + "coeff_2": 0.0934, + "coeff_3": -0.00688, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP2Sp_ClSH_fT", + "category": "ClSH_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 1.54, + "coeff_2": 0.0382752, + "coeff_3": -0.00297756, + "coeff_4": -0.0114912, + "coeff_5": -0.00010044, + "coeff_6": 0.0005346, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP2Sp_EIR_fT", + "category": "EIR_fT", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": -0.172512, + "coeff_2": 0.1176624, + "coeff_3": -0.00324, + "coeff_4": -0.01152, + "coeff_5": 0.00077112, + "coeff_6": -0.00057024, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP2Sp_HIR_fT", + "category": "HIR_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0.9272864, + "coeff_2": 0.00802008, + "coeff_3": 0.000201528, + "coeff_4": -0.02177136, + "coeff_5": 0.000729, + "coeff_6": -0.000303264, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SpltHP2Sp_HtCap_fT", + "category": "HtCap_fT", + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": "T", + "independent_variable_2": "T", + "coeff_1": 0.8756304, + "coeff_2": -0.00466344, + "coeff_3": 1.62e-14, + "coeff_4": 0.02912976, + "coeff_5": 0.00012636, + "coeff_6": -0.000163296, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 7.22222, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": -23.333, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SteamTurbine-Flow-fPSIG", + "category": "SteamTurbineGen", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "PSIG", + "independent_variable_2": "PSIG", + "coeff_1": 38.79236, + "coeff_2": -3.07e-05, + "coeff_3": 1.11e-11, + "coeff_4": 0.000147951, + "coeff_5": 1.93e-11, + "coeff_6": -7.36e-11, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 18, + "maximum_dependent_variable_output": 100, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SteamTurbine-HIR-fPLR", + "category": "SteamTurbineGen", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.12838545, + "coeff_2": 0.90049523, + "coeff_3": -0.02888074, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Stippled_Optical-fAOI", + "category": "PV-Module", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": "AOI", + "independent_variable_2": null, + "coeff_1": 4.70208168, + "coeff_2": -0.21138079, + "coeff_3": 0.00393233, + "coeff_4": -2.4e-05, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "SWH-EFFFPLR-NECB2011", + "category": "Water Heater", + "form": "Cubic", + "dependent_variable": "FIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.7576, + "coeff_2": 1.0071, + "coeff_3": -1.4443, + "coeff_4": 0.6844, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From NECB 2011" + }, + { + "name": "Tower_Fan_Curve", + "category": null, + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 1, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From Prototype Buildings" + }, + { + "name": "Transformer-Loss-fPLR", + "category": "ElecMeters", + "form": "Linear", + "dependent_variable": "QRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.1, + "coeff_2": 0.9, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Two-Speed Fan EIR fPLR", + "category": "FanEIR-FPLR", + "form": "Linear", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": -0.764706, + "coeff_2": 1.764706, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.4, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "TwoSpeedFan", + "category": "FanEIR-FPLR", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.000281, + "coeff_2": -0.0579, + "coeff_3": 0.586, + "coeff_4": 0.471, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Typical VSD Fan", + "category": "FanEIR-FPLR", + "form": "Cubic", + "dependent_variable": "PwrRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.047182815, + "coeff_2": 0.130541742, + "coeff_3": -0.117286942, + "coeff_4": 0.940313747, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.1, + "maximum_dependent_variable_output": null, + "annotation": "From California Energy Commision, \"Advanced Variable Air Volume System Design Guide,\" October 2003" + }, + { + "name": "TypicalCyclingAC-EIR-fPLR", + "category": "CyclingAC", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 6.26e-05, + "coeff_2": 1.17517, + "coeff_3": -0.201513, + "coeff_4": 0.0263344, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Vane Axial w Var Pitch FPLR", + "category": "FanEIR-FPLR", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.212048, + "coeff_2": -0.569286, + "coeff_3": 1.345238, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.15, + "maximum_dependent_variable_output": 1, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Variable Speed Drive FPLR", + "category": "FanEIR-FPLR", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.219762, + "coeff_2": -0.874784, + "coeff_3": 1.652597, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.1, + "maximum_dependent_variable_output": 1, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "VarVolFan-AFBIFanCurve-NECB2011-FPLR", + "category": "Fan", + "form": "Cubic", + "dependent_variable": "PwrRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": -2.4176, + "coeff_2": 9.5874, + "coeff_3": -11.559, + "coeff_4": 5.4009, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.68, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From NECB 2011" + }, + { + "name": "VarVolFan-AFBIInletVanes-NECB2011-FPLR", + "category": "Fan", + "form": "Cubic", + "dependent_variable": "PwrRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": -4.1457, + "coeff_2": 16.803, + "coeff_3": -19.471, + "coeff_4": 7.8488, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.5, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From NECB 2011" + }, + { + "name": "VarVolFan-FCInletVanes-NECB2011-FPLR", + "category": "Fan", + "form": "Cubic", + "dependent_variable": "PwrRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": -0.3477, + "coeff_2": 4.0976, + "coeff_3": -5.0024, + "coeff_4": 2.268, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.22, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From NECB 2011" + }, + { + "name": "VarVolFan-VSD-NECB2011-FPLR", + "category": "Fan", + "form": "Cubic", + "dependent_variable": "PwrRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.1389, + "coeff_2": 1.7699, + "coeff_3": -1.615, + "coeff_4": 0.6996, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.04, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From NECB 2011" + }, + { + "name": "VFD-Loss-fPLR", + "category": "Pumps", + "form": "Linear", + "dependent_variable": "QRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.6, + "coeff_2": 0.4, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "VRF-HP-Resys-ClCap-fSST&ODB", + "category": "CondUnit", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "SST", + "independent_variable_2": "ODB", + "coeff_1": 1.26588416, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": -0.007582032, + "coeff_5": -2.14e-06, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "VRF-HP-Resys-ClEIR-fSST&ODB", + "category": "CondUnit", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "SST", + "independent_variable_2": "ODB", + "coeff_1": 0.384832, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0.0092304, + "coeff_5": 0.000238, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "VRF-HP-Resys-Crankcase-fPLR", + "category": "CondUnit", + "form": "Quadratic", + "dependent_variable": null, + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 1, + "coeff_2": -1.72, + "coeff_3": 0.72, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "VRF-HP-Resys-Cycle-fPLR", + "category": "CondUnit", + "form": "Linear", + "dependent_variable": "QRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.898, + "coeff_2": 0.102, + "coeff_3": null, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "VRF-HP-Resys-HtCap-fSCT&OWB", + "category": "CondUnit", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "SCT", + "independent_variable_2": "OWB", + "coeff_1": 0.89783456, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": 0.016707888, + "coeff_5": 6.16e-07, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "VRF-HP-Resys-HtEIR-fSCT&OWB", + "category": "CondUnit", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "SCT", + "independent_variable_2": "OWB", + "coeff_1": 1.0525344, + "coeff_2": 0, + "coeff_3": 0, + "coeff_4": -0.00815688, + "coeff_5": -8.72e-05, + "coeff_6": 0, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": null, + "maximum_independent_variable_1": null, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "VSD-TWR-FAN-FPLR", + "category": "Cooling Tower", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.33162901, + "coeff_2": -0.88567609, + "coeff_3": 0.60556507, + "coeff_4": 0.9484823, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From PNNL PRM Reference Manual" + }, + { + "name": "Water-Cooled-Bypass-fAirflow", + "category": "DXCooling,WCC", + "form": "Cubic", + "dependent_variable": "QRatio", + "independent_variable_1": "Airflow", + "independent_variable_2": null, + "coeff_1": 0.9, + "coeff_2": -3.73, + "coeff_3": 7.37, + "coeff_4": -3.54, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Water-Cooled-Bypass-fEWB&EWT", + "category": "DXCooling,WCC", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "EWT", + "coeff_1": -5.51104768, + "coeff_2": 0.73563552, + "coeff_3": -0.0185004, + "coeff_4": 0.142520616, + "coeff_5": 0.000942, + "coeff_6": -0.010213452, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Water-Cooled-Cool-Cap-fEWB&EWT", + "category": "DXCooling,WCC", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "EWT", + "coeff_1": 0.8254384, + "coeff_2": 0.00574416, + "coeff_3": 0.000735, + "coeff_4": -0.00310374, + "coeff_5": -1.46e-05, + "coeff_6": -0.000194, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Water-Cooled-EIR-fEWB&EWT", + "category": "DXCooling,WCC", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "EWT", + "coeff_1": 0.0985984, + "coeff_2": 0.062604, + "coeff_3": -0.00184356, + "coeff_4": 0.01183032, + "coeff_5": 0.000292, + "coeff_6": -0.000395, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 12.77778, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Water-Cooled-EIR-fPLR", + "category": "DXCooling,WCC", + "form": "Cubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "PLR", + "independent_variable_2": null, + "coeff_1": 0.201, + "coeff_2": -0.0312, + "coeff_3": 1.9504979, + "coeff_4": -1.1205104, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1.05, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "Water-Cooled-Sens-Cap-fEWB&EWT", + "category": "DXCooling,WCC", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "EWB", + "independent_variable_2": "EWT", + "coeff_1": 2.1542784, + "coeff_2": -0.0242784, + "coeff_3": -0.00148716, + "coeff_4": -0.00829548, + "coeff_5": -2.96e-05, + "coeff_6": 0.000272, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 12.77778, + "maximum_independent_variable_1": 29.44444, + "minimum_independent_variable_2": 10, + "maximum_independent_variable_2": 46.11111, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From .dat files included with MASControl2" + }, + { + "name": "WaterCooled_Centrifugal_CAPFT_NECB2011", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.707908, + "coeff_2": -0.00200657, + "coeff_3": -0.00259605, + "coeff_4": 0.0300588, + "coeff_5": -0.00105643, + "coeff_6": 0.0020457, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 24, + "maximum_independent_variable_2": 35, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From NECB 2011" + }, + { + "name": "WaterCooled_Centrifugal_Chiller_150TO300_2004_EIRFPLR", + "category": "Electric Chiller", + "form": "BiCubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tcws", + "independent_variable_2": "QRatio", + "coeff_1": -0.1360532, + "coeff_2": 0.008642703, + "coeff_3": 3.85558e-06, + "coeff_4": 1.024034, + "coeff_5": 0.06047444, + "coeff_6": -0.00894786, + "coeff_7": 0, + "coeff_8": 0.05706602, + "coeff_9": 0, + "coeff_10": 0, + "minimum_independent_variable_1": 31.13, + "maximum_independent_variable_1": 36.52, + "minimum_independent_variable_2": 0.19, + "maximum_independent_variable_2": 1.03, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_Centrifugal_Chiller_150TO300_2010_PathA_EIRFPLR", + "category": "Electric Chiller", + "form": "BiCubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tcws", + "independent_variable_2": "QRatio", + "coeff_1": -0.1360532, + "coeff_2": 0.008642703, + "coeff_3": 3.85558e-06, + "coeff_4": 1.024034, + "coeff_5": 0.06047444, + "coeff_6": -0.00894786, + "coeff_7": 0, + "coeff_8": 0.05706602, + "coeff_9": 0, + "coeff_10": 0, + "minimum_independent_variable_1": 31.13, + "maximum_independent_variable_1": 36.52, + "minimum_independent_variable_2": 0.19, + "maximum_independent_variable_2": 1.03, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_Centrifugal_Chiller_150TO300_2010_PathB_EIRFPLR", + "category": "Electric Chiller", + "form": "BiCubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tcws", + "independent_variable_2": "QRatio", + "coeff_1": -0.1360532, + "coeff_2": 0.008642703, + "coeff_3": 3.85558e-06, + "coeff_4": 1.024034, + "coeff_5": 0.06047444, + "coeff_6": -0.00894786, + "coeff_7": 0, + "coeff_8": 0.05706602, + "coeff_9": 0, + "coeff_10": 0, + "minimum_independent_variable_1": 31.13, + "maximum_independent_variable_1": 36.52, + "minimum_independent_variable_2": 0.19, + "maximum_independent_variable_2": 1.03, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.7600172, + "coeff_2": 0.0147432, + "coeff_3": 0.0002144, + "coeff_4": 0.0207218, + "coeff_5": -0.0006425, + "coeff_6": 0.0008007, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 17.78, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.6772577, + "coeff_2": 0.0117857, + "coeff_3": -0.0001967, + "coeff_4": 0.0014414, + "coeff_5": 0.0003005, + "coeff_6": -0.0006807, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 17.78, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.536234, + "coeff_2": 0.005581, + "coeff_3": -0.0013654, + "coeff_4": 0.0488966, + "coeff_5": -0.0012018, + "coeff_6": 0.0010523, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 17.78, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 1.0821822, + "coeff_2": 0.0042977, + "coeff_3": -0.0013182, + "coeff_4": -0.0260781, + "coeff_5": 0.0008256, + "coeff_6": -0.0006013, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 17.78, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_Centrifugal_Chiller_300TO600_2010_PathA_EIRFPLR", + "category": "Electric Chiller", + "form": "BiCubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tcws", + "independent_variable_2": "QRatio", + "coeff_1": -0.1360532, + "coeff_2": 0.008642703, + "coeff_3": 3.85558e-06, + "coeff_4": 1.024034, + "coeff_5": 0.06047444, + "coeff_6": -0.00894786, + "coeff_7": 0, + "coeff_8": 0.05706602, + "coeff_9": 0, + "coeff_10": 0, + "minimum_independent_variable_1": 31.13, + "maximum_independent_variable_1": 36.52, + "minimum_independent_variable_2": 0.19, + "maximum_independent_variable_2": 1.03, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_Centrifugal_Chiller_300TO600_2010_PathB_EIRFPLR", + "category": "Electric Chiller", + "form": "BiCubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tcws", + "independent_variable_2": "QRatio", + "coeff_1": -0.1360532, + "coeff_2": 0.008642703, + "coeff_3": 3.85558e-06, + "coeff_4": 1.024034, + "coeff_5": 0.06047444, + "coeff_6": -0.00894786, + "coeff_7": 0, + "coeff_8": 0.05706602, + "coeff_9": 0, + "coeff_10": 0, + "minimum_independent_variable_1": 31.13, + "maximum_independent_variable_1": 36.52, + "minimum_independent_variable_2": 0.19, + "maximum_independent_variable_2": 1.03, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_Centrifugal_Chiller_AllCapacities_2004_2007_2010_EIRFPLR", + "category": "Electric Chiller", + "form": "BiCubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tcws", + "independent_variable_2": "QRatio", + "coeff_1": -0.1360532, + "coeff_2": 0.008642703, + "coeff_3": 3.85558e-06, + "coeff_4": 1.024034, + "coeff_5": 0.06047444, + "coeff_6": -0.00894786, + "coeff_7": 0, + "coeff_8": 0.05706602, + "coeff_9": 0, + "coeff_10": 0, + "minimum_independent_variable_1": 31.13, + "maximum_independent_variable_1": 36.52, + "minimum_independent_variable_2": 0.19, + "maximum_independent_variable_2": 1.03, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010. EIRFPLR curve is identical for all WaterCooled Chillers" + }, + { + "name": "WaterCooled_Centrifugal_Chiller_GT150_2004_CAPFT", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.7600172, + "coeff_2": 0.0147432, + "coeff_3": 0.0002144, + "coeff_4": 0.0207218, + "coeff_5": -0.0006425, + "coeff_6": 0.0008007, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 17.78, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_Centrifugal_Chiller_GT150_2004_EIRFT", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.6772577, + "coeff_2": 0.0117857, + "coeff_3": -0.0001967, + "coeff_4": 0.0014414, + "coeff_5": 0.0003005, + "coeff_6": -0.0006807, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 17.78, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_Centrifugal_Chiller_GT300_2004_EIRFPLR", + "category": "Electric Chiller", + "form": "BiCubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tcws", + "independent_variable_2": "QRatio", + "coeff_1": -0.1360532, + "coeff_2": 0.008642703, + "coeff_3": 3.85558e-06, + "coeff_4": 1.024034, + "coeff_5": 0.06047444, + "coeff_6": -0.00894786, + "coeff_7": 0, + "coeff_8": 0.05706602, + "coeff_9": 0, + "coeff_10": 0, + "minimum_independent_variable_1": 31.13, + "maximum_independent_variable_1": 36.52, + "minimum_independent_variable_2": 0.19, + "maximum_independent_variable_2": 1.03, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_Centrifugal_Chiller_GT600_2010_PathA_EIRFPLR", + "category": "Electric Chiller", + "form": "BiCubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tcws", + "independent_variable_2": "QRatio", + "coeff_1": -0.1360532, + "coeff_2": 0.008642703, + "coeff_3": 3.85558e-06, + "coeff_4": 1.024034, + "coeff_5": 0.06047444, + "coeff_6": -0.00894786, + "coeff_7": 0, + "coeff_8": 0.05706602, + "coeff_9": 0, + "coeff_10": 0, + "minimum_independent_variable_1": 31.13, + "maximum_independent_variable_1": 36.52, + "minimum_independent_variable_2": 0.19, + "maximum_independent_variable_2": 1.03, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_Centrifugal_Chiller_GT600_2010_PathB_EIRFPLR", + "category": "Electric Chiller", + "form": "BiCubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tcws", + "independent_variable_2": "QRatio", + "coeff_1": -0.1360532, + "coeff_2": 0.008642703, + "coeff_3": 3.85558e-06, + "coeff_4": 1.024034, + "coeff_5": 0.06047444, + "coeff_6": -0.00894786, + "coeff_7": 0, + "coeff_8": 0.05706602, + "coeff_9": 0, + "coeff_10": 0, + "minimum_independent_variable_1": 31.13, + "maximum_independent_variable_1": 36.52, + "minimum_independent_variable_2": 0.19, + "maximum_independent_variable_2": 1.03, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_Centrifugal_Chiller_LT150_2004_CAPFT", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.7446451, + "coeff_2": 0.0114858, + "coeff_3": 1.48e-05, + "coeff_4": 0.022401, + "coeff_5": -0.000688, + "coeff_6": 0.0009839, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 17.78, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFPLR", + "category": "Electric Chiller", + "form": "BiCubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tcws", + "independent_variable_2": "QRatio", + "coeff_1": -0.1360532, + "coeff_2": 0.008642703, + "coeff_3": 3.85558e-06, + "coeff_4": 1.024034, + "coeff_5": 0.06047444, + "coeff_6": -0.00894786, + "coeff_7": 0, + "coeff_8": 0.05706602, + "coeff_9": 0, + "coeff_10": 0, + "minimum_independent_variable_1": 31.13, + "maximum_independent_variable_1": 36.52, + "minimum_independent_variable_2": 0.19, + "maximum_independent_variable_2": 1.03, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFT", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.772877, + "coeff_2": 0.022101, + "coeff_3": -7.99e-05, + "coeff_4": -0.0070045, + "coeff_5": 0.0004763, + "coeff_6": -0.0010612, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 17.78, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_Centrifugal_Chiller_LT150_2010_PathA_EIRFPLR", + "category": "Electric Chiller", + "form": "BiCubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tcws", + "independent_variable_2": "QRatio", + "coeff_1": -0.1360532, + "coeff_2": 0.008642703, + "coeff_3": 3.85558e-06, + "coeff_4": 1.024034, + "coeff_5": 0.06047444, + "coeff_6": -0.00894786, + "coeff_7": 0, + "coeff_8": 0.05706602, + "coeff_9": 0, + "coeff_10": 0, + "minimum_independent_variable_1": 31.13, + "maximum_independent_variable_1": 36.52, + "minimum_independent_variable_2": 0.19, + "maximum_independent_variable_2": 1.03, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_Centrifugal_Chiller_LT150_2010_PathB_EIRFPLR", + "category": "Electric Chiller", + "form": "BiCubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tcws", + "independent_variable_2": "QRatio", + "coeff_1": -0.1360532, + "coeff_2": 0.008642703, + "coeff_3": 3.85558e-06, + "coeff_4": 1.024034, + "coeff_5": 0.06047444, + "coeff_6": -0.00894786, + "coeff_7": 0, + "coeff_8": 0.05706602, + "coeff_9": 0, + "coeff_10": 0, + "minimum_independent_variable_1": 31.13, + "maximum_independent_variable_1": 36.52, + "minimum_independent_variable_2": 0.19, + "maximum_independent_variable_2": 1.03, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_Centrifugal_EIRFPLR_NECB2011", + "category": "Electric Chiller", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.171493, + "coeff_2": 0.588202, + "coeff_3": 0.237373, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From NECB 2011" + }, + { + "name": "WaterCooled_Centrifugal_EIRFT_NECB2011", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.560523, + "coeff_2": -0.0137816, + "coeff_3": 6.56424e-05, + "coeff_4": 0.0132194, + "coeff_5": 0.000268596, + "coeff_6": -0.000501131, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 24, + "maximum_independent_variable_2": 35, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From NECB 2011" + }, + { + "name": "WaterCooled_PositiveDisplacement_Chiller_150TO300_2004_EIRFPLR", + "category": "Electric Chiller", + "form": "BiCubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tcws", + "independent_variable_2": "QRatio", + "coeff_1": -0.1360532, + "coeff_2": 0.008642703, + "coeff_3": 3.85558e-06, + "coeff_4": 1.024034, + "coeff_5": 0.06047444, + "coeff_6": -0.00894786, + "coeff_7": 0, + "coeff_8": 0.05706602, + "coeff_9": 0, + "coeff_10": 0, + "minimum_independent_variable_1": 31.13, + "maximum_independent_variable_1": 36.52, + "minimum_independent_variable_2": 0.19, + "maximum_independent_variable_2": 1.03, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_PositiveDisplacement_Chiller_150TO300_2010_PathA_EIRFPLR", + "category": "Electric Chiller", + "form": "BiCubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tcws", + "independent_variable_2": "QRatio", + "coeff_1": -0.1360532, + "coeff_2": 0.008642703, + "coeff_3": 3.85558e-06, + "coeff_4": 1.024034, + "coeff_5": 0.06047444, + "coeff_6": -0.00894786, + "coeff_7": 0, + "coeff_8": 0.05706602, + "coeff_9": 0, + "coeff_10": 0, + "minimum_independent_variable_1": 31.13, + "maximum_independent_variable_1": 36.52, + "minimum_independent_variable_2": 0.19, + "maximum_independent_variable_2": 1.03, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_PositiveDisplacement_Chiller_150TO300_2010_PathB_EIRFPLR", + "category": "Electric Chiller", + "form": "BiCubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tcws", + "independent_variable_2": "QRatio", + "coeff_1": -0.1360532, + "coeff_2": 0.008642703, + "coeff_3": 3.85558e-06, + "coeff_4": 1.024034, + "coeff_5": 0.06047444, + "coeff_6": -0.00894786, + "coeff_7": 0, + "coeff_8": 0.05706602, + "coeff_9": 0, + "coeff_10": 0, + "minimum_independent_variable_1": 31.13, + "maximum_independent_variable_1": 36.52, + "minimum_independent_variable_2": 0.19, + "maximum_independent_variable_2": 1.03, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_PositiveDisplacement_Chiller_2004_CAPFT", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.906115, + "coeff_2": 0.029227, + "coeff_3": -0.0003647, + "coeff_4": -0.0009709, + "coeff_5": -9.05e-05, + "coeff_6": 0.0002527, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 17.78, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_PositiveDisplacement_Chiller_2004_EIRFT", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.3617105, + "coeff_2": -0.0229833, + "coeff_3": 0.0009519, + "coeff_4": 0.0131889, + "coeff_5": 0.0003752, + "coeff_6": -0.0007059, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 17.78, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_PositiveDisplacement_Chiller_2010_PathB_CAPFT", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.9061171, + "coeff_2": 0.0292267, + "coeff_3": -0.0003665, + "coeff_4": -0.0009698, + "coeff_5": -9.07e-05, + "coeff_6": 0.0002535, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 17.78, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_PositiveDisplacement_Chiller_2010_PathB_EIRFT", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.3617782, + "coeff_2": -0.0230016, + "coeff_3": 0.0009672, + "coeff_4": 0.0131801, + "coeff_5": 0.0003761, + "coeff_6": -0.0007121, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 17.78, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_PositiveDisplacement_Chiller_75TO150_2004_EIRFPLR", + "category": "Electric Chiller", + "form": "BiCubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tcws", + "independent_variable_2": "QRatio", + "coeff_1": -0.1360532, + "coeff_2": 0.008642703, + "coeff_3": 3.85558e-06, + "coeff_4": 1.024034, + "coeff_5": 0.06047444, + "coeff_6": -0.00894786, + "coeff_7": 0, + "coeff_8": 0.05706602, + "coeff_9": 0, + "coeff_10": 0, + "minimum_independent_variable_1": 31.13, + "maximum_independent_variable_1": 36.52, + "minimum_independent_variable_2": 0.19, + "maximum_independent_variable_2": 1.03, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_PositiveDisplacement_Chiller_75TO150_2010_PathA_EIRFPLR", + "category": "Electric Chiller", + "form": "BiCubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tcws", + "independent_variable_2": "QRatio", + "coeff_1": -0.1360532, + "coeff_2": 0.008642703, + "coeff_3": 3.85558e-06, + "coeff_4": 1.024034, + "coeff_5": 0.06047444, + "coeff_6": -0.00894786, + "coeff_7": 0, + "coeff_8": 0.05706602, + "coeff_9": 0, + "coeff_10": 0, + "minimum_independent_variable_1": 31.13, + "maximum_independent_variable_1": 36.52, + "minimum_independent_variable_2": 0.19, + "maximum_independent_variable_2": 1.03, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_PositiveDisplacement_Chiller_75TO150_2010_PathB_EIRFPLR", + "category": "Electric Chiller", + "form": "BiCubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tcws", + "independent_variable_2": "QRatio", + "coeff_1": -0.1360532, + "coeff_2": 0.008642703, + "coeff_3": 3.85558e-06, + "coeff_4": 1.024034, + "coeff_5": 0.06047444, + "coeff_6": -0.00894786, + "coeff_7": 0, + "coeff_8": 0.05706602, + "coeff_9": 0, + "coeff_10": 0, + "minimum_independent_variable_1": 31.13, + "maximum_independent_variable_1": 36.52, + "minimum_independent_variable_2": 0.19, + "maximum_independent_variable_2": 1.03, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.906115, + "coeff_2": 0.0292277, + "coeff_3": -0.0003647, + "coeff_4": -0.0009709, + "coeff_5": -9.05e-05, + "coeff_6": 0.0002527, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 17.78, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.3773115, + "coeff_2": -0.0229032, + "coeff_3": 0.0016504, + "coeff_4": 0.0118156, + "coeff_5": 0.0004345, + "coeff_6": -0.0010132, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 17.78, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_PositiveDisplacement_Chiller_GT300_2004_EIRFPLR", + "category": "Electric Chiller", + "form": "BiCubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tcws", + "independent_variable_2": "QRatio", + "coeff_1": -0.1360532, + "coeff_2": 0.008642703, + "coeff_3": 3.85558e-06, + "coeff_4": 1.024034, + "coeff_5": 0.06047444, + "coeff_6": -0.00894786, + "coeff_7": 0, + "coeff_8": 0.05706602, + "coeff_9": 0, + "coeff_10": 0, + "minimum_independent_variable_1": 31.13, + "maximum_independent_variable_1": 36.52, + "minimum_independent_variable_2": 0.19, + "maximum_independent_variable_2": 1.03, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_PositiveDisplacement_Chiller_GT300_2010_PathA_EIRFPLR", + "category": "Electric Chiller", + "form": "BiCubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tcws", + "independent_variable_2": "QRatio", + "coeff_1": -0.1360532, + "coeff_2": 0.008642703, + "coeff_3": 3.85558e-06, + "coeff_4": 1.024034, + "coeff_5": 0.06047444, + "coeff_6": -0.00894786, + "coeff_7": 0, + "coeff_8": 0.05706602, + "coeff_9": 0, + "coeff_10": 0, + "minimum_independent_variable_1": 31.13, + "maximum_independent_variable_1": 36.52, + "minimum_independent_variable_2": 0.19, + "maximum_independent_variable_2": 1.03, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_PositiveDisplacement_Chiller_GT300_2010_PathB_EIRFPLR", + "category": "Electric Chiller", + "form": "BiCubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tcws", + "independent_variable_2": "QRatio", + "coeff_1": -0.1360532, + "coeff_2": 0.008642703, + "coeff_3": 3.85558e-06, + "coeff_4": 1.024034, + "coeff_5": 0.06047444, + "coeff_6": -0.00894786, + "coeff_7": 0, + "coeff_8": 0.05706602, + "coeff_9": 0, + "coeff_10": 0, + "minimum_independent_variable_1": 31.13, + "maximum_independent_variable_1": 36.52, + "minimum_independent_variable_2": 0.19, + "maximum_independent_variable_2": 1.03, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.906115, + "coeff_2": 0.0292277, + "coeff_3": -0.0003647, + "coeff_4": -0.0009709, + "coeff_5": -9.05e-05, + "coeff_6": 0.0002527, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 17.78, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.3617105, + "coeff_2": -0.0229833, + "coeff_3": 0.0009519, + "coeff_4": 0.0131889, + "coeff_5": 0.0003752, + "coeff_6": -0.0007059, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 17.78, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_PositiveDisplacement_Chiller_LT75_2004_EIRFPLR", + "category": "Electric Chiller", + "form": "BiCubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tcws", + "independent_variable_2": "QRatio", + "coeff_1": -0.1360532, + "coeff_2": 0.008642703, + "coeff_3": 3.85558e-06, + "coeff_4": 1.024034, + "coeff_5": 0.06047444, + "coeff_6": -0.00894786, + "coeff_7": 0, + "coeff_8": 0.05706602, + "coeff_9": 0, + "coeff_10": 0, + "minimum_independent_variable_1": 31.13, + "maximum_independent_variable_1": 36.52, + "minimum_independent_variable_2": 0.19, + "maximum_independent_variable_2": 1.03, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_PositiveDisplacement_Chiller_LT75_2010_PathA_EIRFPLR", + "category": "Electric Chiller", + "form": "BiCubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tcws", + "independent_variable_2": "QRatio", + "coeff_1": -0.1360532, + "coeff_2": 0.008642703, + "coeff_3": 3.85558e-06, + "coeff_4": 1.024034, + "coeff_5": 0.06047444, + "coeff_6": -0.00894786, + "coeff_7": 0, + "coeff_8": 0.05706602, + "coeff_9": 0, + "coeff_10": 0, + "minimum_independent_variable_1": 31.13, + "maximum_independent_variable_1": 36.52, + "minimum_independent_variable_2": 0.19, + "maximum_independent_variable_2": 1.03, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_PositiveDisplacement_Chiller_LT75_2010_PathB_EIRFPLR", + "category": "Electric Chiller", + "form": "BiCubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tcws", + "independent_variable_2": "QRatio", + "coeff_1": -0.1360532, + "coeff_2": 0.008642703, + "coeff_3": 3.85558e-06, + "coeff_4": 1.024034, + "coeff_5": 0.06047444, + "coeff_6": -0.00894786, + "coeff_7": 0, + "coeff_8": 0.05706602, + "coeff_9": 0, + "coeff_10": 0, + "minimum_independent_variable_1": 31.13, + "maximum_independent_variable_1": 36.52, + "minimum_independent_variable_2": 0.19, + "maximum_independent_variable_2": 1.03, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "Based on Dick Lord's study dated January 17, 2010." + }, + { + "name": "WaterCooled_Reciprocating_CAPFT_NECB2011", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 1.03031, + "coeff_2": 0.0334698, + "coeff_3": 0.00023639, + "coeff_4": -0.00729587, + "coeff_5": -2.3166e-05, + "coeff_6": -0.000148943, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 24, + "maximum_independent_variable_2": 35, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From NECB 2011" + }, + { + "name": "WaterCooled_Reciprocating_EIRFPLR_NECB2011", + "category": "Electric Chiller", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.081441, + "coeff_2": 0.419271, + "coeff_3": 0.499396, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From NECB 2011" + }, + { + "name": "WaterCooled_Reciprocating_EIRFT_NECB2011", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.499699, + "coeff_2": -0.0130841, + "coeff_3": 0.000266425, + "coeff_4": 0.0165925, + "coeff_5": 0.000185393, + "coeff_6": -0.000375646, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 24, + "maximum_independent_variable_2": 35, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From NECB 2011" + }, + { + "name": "WaterCooled_Screw_CAPFT_NECB2011", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.812998, + "coeff_2": -0.0142532, + "coeff_3": -0.00161799, + "coeff_4": 0.0263844, + "coeff_5": -0.00091543, + "coeff_6": 0.00169601, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 24, + "maximum_independent_variable_2": 35, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From NECB 2011" + }, + { + "name": "WaterCooled_Screw_EIRFPLR_NECB2011", + "category": "Electric Chiller", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.330188, + "coeff_2": 0.235543, + "coeff_3": 0.460708, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From NECB 2011" + }, + { + "name": "WaterCooled_Screw_EIRFT_NECB2011", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.638103, + "coeff_2": 0.00630158, + "coeff_3": 0.00092327, + "coeff_4": -0.00455294, + "coeff_5": 0.000825682, + "coeff_6": -0.00156152, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 24, + "maximum_independent_variable_2": 35, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From NECB 2011" + }, + { + "name": "WaterCooled_Scroll_CAPFT_NECB2011", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.94418, + "coeff_2": 0.0337102, + "coeff_3": 9.75564e-05, + "coeff_4": -0.00322114, + "coeff_5": -4.91832e-05, + "coeff_6": -0.000177584, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 24, + "maximum_independent_variable_2": 35, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From NECB 2011" + }, + { + "name": "WaterCooled_Scroll_EIRFPLR_NECB2011", + "category": "Electric Chiller", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "QRatio", + "independent_variable_2": null, + "coeff_1": 0.04412, + "coeff_2": 0.640367, + "coeff_3": 0.319555, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 1, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From NECB 2011" + }, + { + "name": "WaterCooled_Scroll_EIRFT_NECB2011", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.727393, + "coeff_2": -0.0118922, + "coeff_3": 0.000541177, + "coeff_4": 0.00187934, + "coeff_5": 0.000473461, + "coeff_6": -0.000711472, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 24, + "maximum_independent_variable_2": 35, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From NECB 2011" + }, + { + "name": "WC Screw Default 90.1-2004 Cap_fTWC", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "QRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.906115, + "coeff_2": 0.0292277, + "coeff_3": -0.0003647, + "coeff_4": -0.0009709, + "coeff_5": -9.05e-05, + "coeff_6": 0.0002527, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 20, + "minimum_independent_variable_2": 0, + "maximum_independent_variable_2": 50, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From RefBldgLargeOfficePost1980 & Pre1980" + }, + { + "name": "WC Screw Default 90.1-2004 EIR_fT", + "category": "Electric Chiller", + "form": "BiQuadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tchws", + "independent_variable_2": "Toadb", + "coeff_1": 0.3617105, + "coeff_2": -0.0229833, + "coeff_3": -0.0009519, + "coeff_4": 0.0131889, + "coeff_5": 0.0003752, + "coeff_6": -0.0007059, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0, + "maximum_independent_variable_1": 20, + "minimum_independent_variable_2": 0, + "maximum_independent_variable_2": 50, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From RefBldgLargeOfficePost1980 % Pre1980" + }, + { + "name": "WC Screw GTE 300tons Default 90.1-2004 EIR_fPLR", + "category": "Electric Chiller", + "form": "BiCubic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "Tcws", + "independent_variable_2": "QRatio", + "coeff_1": -0.2737954, + "coeff_2": 0.02822257, + "coeff_3": -8.09766e-05, + "coeff_4": 0.9612284, + "coeff_5": 0.3029741, + "coeff_6": -0.02421933, + "coeff_7": 0, + "coeff_8": -0.03885224, + "coeff_9": 0, + "coeff_10": 0, + "minimum_independent_variable_1": 18.54, + "maximum_independent_variable_1": 31.63, + "minimum_independent_variable_2": 0.2, + "maximum_independent_variable_2": 1.02, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From RefBldgLargeOfficePost1980 & Pre1980" + }, + { + "name": "WC_PD_2004_CAPFT", + "category": null, + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.906115, + "coeff_2": 0.0292277, + "coeff_3": -0.0003647, + "coeff_4": -0.0009709, + "coeff_5": -9.05e-05, + "coeff_6": 0.0002527, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 17.78, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From PNNL Prototype Hospital" + }, + { + "name": "WC_PD_2010_PB_CAPFT", + "category": null, + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.9061171, + "coeff_2": 0.0292267, + "coeff_3": -0.0003665, + "coeff_4": -0.0009698, + "coeff_5": -9.07e-05, + "coeff_6": 0.0002535, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 17.78, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From PNNL Prototype OfficeLarge" + }, + { + "name": "WC_PD_2010_PB_EIRFT", + "category": null, + "form": "BiQuadratic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.3617782, + "coeff_2": -0.0230016, + "coeff_3": 0.0009672, + "coeff_4": 0.0131801, + "coeff_5": 0.0003761, + "coeff_6": -0.0007121, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 5, + "maximum_independent_variable_1": 10, + "minimum_independent_variable_2": 17.78, + "maximum_independent_variable_2": 46.11, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From PNNL Prototype OfficeLarge" + }, + { + "name": "MT_compressor_power", + "category": "Refrigeration", + "form": "BiCubic", + "dependent_variable": "Power", + "independent_variable_1": "Suction T", + "independent_variable_2": "Discharge T", + "coeff_1": 7438.92229, + "coeff_2": -269.59756, + "coeff_3": -9.8561045, + "coeff_4": 553.57326, + "coeff_5": -3.3858896, + "coeff_6": 14.8657878, + "coeff_7": -0.1007963, + "coeff_8": 0.00982279, + "coeff_9": 0.09736236, + "coeff_10": -0.039675217, + "minimum_independent_variable_1": -23.3, + "maximum_independent_variable_1": 7.2, + "minimum_independent_variable_2": 10, + "maximum_independent_variable_2": 60, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From AEDG" + }, + { + "name": "MT_compressor_capacity", + "category": "Refrigeration", + "form": "BiCubic", + "dependent_variable": "Capacity", + "independent_variable_1": "Suction T", + "independent_variable_2": "Discharge T", + "coeff_1": 151166.436, + "coeff_2": 5266.34789, + "coeff_3": 60.6727151, + "coeff_4": -1851.5594, + "coeff_5": 5.73132755, + "coeff_6": -46.927717, + "coeff_7": 0.1364012, + "coeff_8": -0.0356979, + "coeff_9": -0.403054, + "coeff_10": -0.039290478, + "minimum_independent_variable_1": -23.3, + "maximum_independent_variable_1": -7.2, + "minimum_independent_variable_2": 10, + "maximum_independent_variable_2": 60, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From AEDG" + }, + { + "name": "MT_compressor_capacity_smallandold", + "category": "Refrigeration", + "form": "BiCubic", + "dependent_variable": "Capacity", + "independent_variable_1": "Suction T", + "independent_variable_2": "Discharge T", + "coeff_1": 15000, + "coeff_2": 541.8, + "coeff_3": 7.285, + "coeff_4": -118, + "coeff_5": -0.3645, + "coeff_6": -3.05, + "coeff_7": 0.0344, + "coeff_8": 0.00225, + "coeff_9": -0.03927, + "coeff_10": -0.007307, + "minimum_independent_variable_1": -17.8, + "maximum_independent_variable_1": 4.4, + "minimum_independent_variable_2": 10, + "maximum_independent_variable_2": 48.9, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From EP DataSets" + }, + { + "name": "MT_compressor_power_smallandold", + "category": "Refrigeration", + "form": "BiCubic", + "dependent_variable": "Power", + "independent_variable_1": "Suction T", + "independent_variable_2": "Discharge T", + "coeff_1": 483.6, + "coeff_2": -53.2, + "coeff_3": -1.384, + "coeff_4": 56.19, + "coeff_5": 0.003688, + "coeff_6": 1.439, + "coeff_7": -0.008268, + "coeff_8": -0.00281, + "coeff_9": 0.007222, + "coeff_10": 0.006025, + "minimum_independent_variable_1": -17.8, + "maximum_independent_variable_1": 4.4, + "minimum_independent_variable_2": 10, + "maximum_independent_variable_2": 48.9, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From EP DataSets" + }, + { + "name": "LT_compressor_capacity_smallandold", + "category": "Refrigeration", + "form": "BiCubic", + "dependent_variable": "Capacity", + "independent_variable_1": "Suction T", + "independent_variable_2": "Discharge T", + "coeff_1": 23500, + "coeff_2": 816.7, + "coeff_3": 10.7, + "coeff_4": -28.24, + "coeff_5": 0.1131, + "coeff_6": -0.4553, + "coeff_7": 0.05604, + "coeff_8": -0.00412, + "coeff_9": -0.006728, + "coeff_10": 0.006782, + "minimum_independent_variable_1": -40, + "maximum_independent_variable_1": -17.8, + "minimum_independent_variable_2": 10, + "maximum_independent_variable_2": 48.9, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From EP DataSets" + }, + { + "name": "LT_compressor_power_smallandold", + "category": "Refrigeration", + "form": "BiCubic", + "dependent_variable": "Power", + "independent_variable_1": "Suction T", + "independent_variable_2": "Discharge T", + "coeff_1": 4018, + "coeff_2": 95, + "coeff_3": 1.507, + "coeff_4": 5.705, + "coeff_5": 1.247, + "coeff_6": -1.381, + "coeff_7": 0.01277, + "coeff_8": -0.007518, + "coeff_9": -0.02424, + "coeff_10": 0.02917, + "minimum_independent_variable_1": -40, + "maximum_independent_variable_1": -17.8, + "minimum_independent_variable_2": 10, + "maximum_independent_variable_2": 48.9, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From EP DataSets" + }, + { + "name": "Glass Door Latent Curve Case", + "category": "Refrigeration", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.3379, + "coeff_2": 0.0309, + "coeff_3": 0.0005, + "coeff_4": 4e-05, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -55, + "maximum_independent_variable_1": 55, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From AEDG" + }, + { + "name": "Coffin Latent Curve Case", + "category": "Refrigeration", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.3379, + "coeff_2": 0.0309, + "coeff_3": 0.0005, + "coeff_4": 4e-05, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -55, + "maximum_independent_variable_1": 55, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From AEDG" + }, + { + "name": "Open Latent Curve Case", + "category": "Refrigeration", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": -0.0187, + "coeff_2": 0.0458, + "coeff_3": 0.0011, + "coeff_4": 5e-05, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -55, + "maximum_independent_variable_1": 55, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From AEDG" + }, + { + "name": "Glass Door Defrost Curve Walkin", + "category": "Refrigeration", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.3475, + "coeff_2": 0.0296, + "coeff_3": 0.0007, + "coeff_4": 3e-05, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -55, + "maximum_independent_variable_1": 55, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From AEDG" + }, + { + "name": "Coffin Defrost Curve Walkin", + "category": "Refrigeration", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.3475, + "coeff_2": 0.0296, + "coeff_3": 0.0007, + "coeff_4": 3e-05, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -55, + "maximum_independent_variable_1": 55, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From AEDG" + }, + { + "name": "Open Defrost Curve Walkin", + "category": "Refrigeration", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.0572, + "coeff_2": 0.0461, + "coeff_3": 0.0004, + "coeff_4": 6e-05, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -55, + "maximum_independent_variable_1": 55, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": "From AEDG" + }, + { + "name": "Refrigeration Case Latent Credit Curve", + "category": "Refrigeration", + "form": "Cubic", + "dependent_variable": null, + "independent_variable_1": null, + "independent_variable_2": null, + "coeff_1": 0.026526281, + "coeff_2": 0.001078032, + "coeff_3": 6.02558e-05, + "coeff_4": 1.23732e-06, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": -35, + "maximum_independent_variable_1": 20, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "annotation": null + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/support_standard_templates.json b/data/openstudio_standards_data/database_files/support_standard_templates.json new file mode 100644 index 0000000000..60805e67c2 --- /dev/null +++ b/data/openstudio_standards_data/database_files/support_standard_templates.json @@ -0,0 +1,16 @@ +[ + { + "template": "90.1-2019", + "lighting_standard": "ASHRAE 90.1-2019", + "lighting_standard_table": "level_3_lighting_90_1_2019", + "ventilation_standard": "ASHRAE 62.1-2019", + "ventilation_standard_table": "level_3_ventilation_90_1_2019" + }, + { + "template": "90.1-2004", + "lighting_standard": "ASHRAE 90.1-2004", + "lighting_standard_table": "level_3_lighting_90_1_2004", + "ventilation_standard": "ASHRAE 62.1-2004", + "ventilation_standard_table": "level_3_ventilation_90_1_2004" + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/support_ventilation_space_type_name_tags.json b/data/openstudio_standards_data/database_files/support_ventilation_space_type_name_tags.json new file mode 100644 index 0000000000..702476a7e5 --- /dev/null +++ b/data/openstudio_standards_data/database_files/support_ventilation_space_type_name_tags.json @@ -0,0 +1,332 @@ +[ + { + "ventilation_space_type_name": "correctional_facilities_cell" + }, + { + "ventilation_space_type_name": "correctional_facilities_dayroom" + }, + { + "ventilation_space_type_name": "correctional_facilities_guard_stations" + }, + { + "ventilation_space_type_name": "correctional_facilities_booking_waiting" + }, + { + "ventilation_space_type_name": "educational_facilities_daycare" + }, + { + "ventilation_space_type_name": "educational_facilities_classroom_young" + }, + { + "ventilation_space_type_name": "educational_facilities_classroom_old" + }, + { + "ventilation_space_type_name": "educational_facilities_lecture_classroom" + }, + { + "ventilation_space_type_name": "educational_facilities_lecture_hall" + }, + { + "ventilation_space_type_name": "educational_facilities_art_classroom" + }, + { + "ventilation_space_type_name": "educational_facilities_science_laboratories" + }, + { + "ventilation_space_type_name": "educational_facilities_wood_metal_shop" + }, + { + "ventilation_space_type_name": "educational_facilities_computer_lab" + }, + { + "ventilation_space_type_name": "educational_facilities_media_center" + }, + { + "ventilation_space_type_name": "educational_facilities_music_theater_dance" + }, + { + "ventilation_space_type_name": "educational_facilities_multiuse_assembly" + }, + { + "ventilation_space_type_name": "educational_facilities_daycare_sickroom" + }, + { + "ventilation_space_type_name": "educational_facilities_libraries" + }, + { + "ventilation_space_type_name": "educational_facilities_university_college_laboratories" + }, + { + "ventilation_space_type_name": "food_beverage_service_restaurant_dining_rooms" + }, + { + "ventilation_space_type_name": "food_beverage_service_cafeteria_fast_food_dining" + }, + { + "ventilation_space_type_name": "food_beverage_service_bars_cocktail_lounges" + }, + { + "ventilation_space_type_name": "food_beverage_service_kitchen" + }, + { + "ventilation_space_type_name": "general_conference_meeting" + }, + { + "ventilation_space_type_name": "general_conference_corridors" + }, + { + "ventilation_space_type_name": "general_conference_storage_rooms" + }, + { + "ventilation_space_type_name": "general_break_rooms" + }, + { + "ventilation_space_type_name": "general_coffee_stations" + }, + { + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_bedroom_living_room" + }, + { + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_barracks_sleeping_areas" + }, + { + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_lobbies_prefunction" + }, + { + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_multi_purpose_assembly" + }, + { + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_laundry_rooms" + }, + { + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_laundry_rooms_w_dwelling_units" + }, + { + "ventilation_space_type_name": "office_buildings_office_space" + }, + { + "ventilation_space_type_name": "office_buildings_reception_areas" + }, + { + "ventilation_space_type_name": "office_buildings_telephone_data_entry" + }, + { + "ventilation_space_type_name": "office_buildings_main_entry_lobbies" + }, + { + "ventilation_space_type_name": "office_buildings_breakrooms" + }, + { + "ventilation_space_type_name": "office_buildings_occupiable_storage_rooms" + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_bank_ vaults_safe_deposit" + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_computer" + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_pharmacy" + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_photo_studios" + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_shipping_receiving" + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_transportation_waiting" + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_warehouses" + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_banks_bank_lobbies" + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_freezer_refrigerated_spaces" + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_wo_hazardous_materials" + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_w_hazardous_materials" + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_sorting_packing_light_assembly" + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_telephone_closets" + }, + { + "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area" + }, + { + "ventilation_space_type_name": "public_assembly_spaces_religious_workshop" + }, + { + "ventilation_space_type_name": "public_assembly_spaces_courtrooms" + }, + { + "ventilation_space_type_name": "public_assembly_spaces_legislative_chambers" + }, + { + "ventilation_space_type_name": "public_assembly_spaces_libraries" + }, + { + "ventilation_space_type_name": "public_assembly_spaces_lobbies" + }, + { + "ventilation_space_type_name": "public_assembly_spaces_children_museums" + }, + { + "ventilation_space_type_name": "public_assembly_spaces_museums_galleries" + }, + { + "ventilation_space_type_name": "retail_sales" + }, + { + "ventilation_space_type_name": "retail_mall_common_areas" + }, + { + "ventilation_space_type_name": "retail_barbershop" + }, + { + "ventilation_space_type_name": "retail_beauty_nail_salons" + }, + { + "ventilation_space_type_name": "retail_pet_shops" + }, + { + "ventilation_space_type_name": "retail_supermarket" + }, + { + "ventilation_space_type_name": "retail_coin_operated_laundries" + }, + { + "ventilation_space_type_name": "sports_entertainment_sports_arena" + }, + { + "ventilation_space_type_name": "sports_entertainment_gym_stadium" + }, + { + "ventilation_space_type_name": "sports_entertainment_spectator_areas" + }, + { + "ventilation_space_type_name": "sports_entertainment_swimming" + }, + { + "ventilation_space_type_name": "sports_entertainment_disco_dance_floors" + }, + { + "ventilation_space_type_name": "sports_entertainment_health_club_aerobics_room" + }, + { + "ventilation_space_type_name": "sports_entertainment_health_club_weight_rooms" + }, + { + "ventilation_space_type_name": "sports_entertainment_bowling_alley" + }, + { + "ventilation_space_type_name": "sports_entertainment_gambling_casinos" + }, + { + "ventilation_space_type_name": "sports_entertainment_game_arcades" + }, + { + "ventilation_space_type_name": "sports_entertainment_stages_studios" + }, + { + "ventilation_space_type_name": "animal_facilities_animal_exam_room" + }, + { + "ventilation_space_type_name": "animal_facilities_animal_imaging" + }, + { + "ventilation_space_type_name": "animal_facilities_animal_operating_rooms" + }, + { + "ventilation_space_type_name": "animal_facilities_animal_postoperative_recovery_room" + }, + { + "ventilation_space_type_name": "animal_facilities_animal_preparation_rooms" + }, + { + "ventilation_space_type_name": "animal_facilities_animal_procedure_room" + }, + { + "ventilation_space_type_name": "animal_facilities_animal_surgery_scrub" + }, + { + "ventilation_space_type_name": "animal_facilities_large_animal_holding_room" + }, + { + "ventilation_space_type_name": "animal_facilities_necropsy" + }, + { + "ventilation_space_type_name": "animal_facilities_small_animal_cage_room_static" + }, + { + "ventilation_space_type_name": "animal_facilities_small_animal_cage_room_ventilated" + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_birthing_room" + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_class_1_imaging_rooms" + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_dental_operatory" + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_general_examination_room" + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_other_dental_treatment_areas" + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_physical_therapy_exercise_area" + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_physical_therapy_individual_room" + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_physical_therapeutic_pool_area" + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_prosthetics_orthotics_room" + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_psychiatric_consultation_room" + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_psychiatric_examination_room" + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_psychiatric_group_room" + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_psychiatric_seclusion_room" + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_speech_therapy_room" + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_urgent_care_examination_room" + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_urgent_care_observation_room" + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_urgent_care_treatment_room" + }, + { + "ventilation_space_type_name": "outpatient_health_care_facilities_urgent_care_triage_room" + }, + { + "ventilation_space_type_name": "transient_residential_common_corridors" + }, + { + "ventilation_space_type_name": "transient_residential_dwelling_unit" + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/system_requirement_economizer_90_1.json b/data/openstudio_standards_data/database_files/system_requirement_economizer_90_1.json new file mode 100644 index 0000000000..81c03583c7 --- /dev/null +++ b/data/openstudio_standards_data/database_files/system_requirement_economizer_90_1.json @@ -0,0 +1,3970 @@ +[ + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-1A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-1A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-1B", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-1B", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-2A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-2A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-2B", + "data_center": "FALSE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-2B", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-3A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-3A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-3B", + "data_center": "FALSE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-3B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-3C", + "data_center": "FALSE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-3C", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-4A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-4A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-4B", + "data_center": "FALSE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-4B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-4C", + "data_center": "FALSE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-4C", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-5A", + "data_center": "FALSE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-5A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-5B", + "data_center": "FALSE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-5B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-5C", + "data_center": "FALSE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-5C", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-6A", + "data_center": "FALSE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-6A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-6B", + "data_center": "FALSE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-6B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-7A", + "data_center": "FALSE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-7A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-7B", + "data_center": "FALSE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-7B", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-8A", + "data_center": "FALSE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-8A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-8B", + "data_center": "FALSE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-8B", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-1A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-1A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-1B", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-1B", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-2A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-2A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-2B", + "data_center": "FALSE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-2B", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-3A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-3A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-3B", + "data_center": "FALSE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-3B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-3C", + "data_center": "FALSE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-3C", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-4A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-4A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-4B", + "data_center": "FALSE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-4B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-4C", + "data_center": "FALSE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-4C", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-5A", + "data_center": "FALSE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-5A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-5B", + "data_center": "FALSE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-5B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-5C", + "data_center": "FALSE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-5C", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-6A", + "data_center": "FALSE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-6A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-6B", + "data_center": "FALSE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-6B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-7A", + "data_center": "FALSE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-7A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-7B", + "data_center": "FALSE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-7B", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-8A", + "data_center": "FALSE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-8A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-8B", + "data_center": "FALSE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-8B", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-1A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-1A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-1B", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-1B", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-2A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-2A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-2B", + "data_center": "FALSE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-2B", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-3A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-3A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-3B", + "data_center": "FALSE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-3B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-3C", + "data_center": "FALSE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-3C", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-4A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-4A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-4B", + "data_center": "FALSE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-4B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-4C", + "data_center": "FALSE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-4C", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-5A", + "data_center": "FALSE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-5A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-5B", + "data_center": "FALSE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-5B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-5C", + "data_center": "FALSE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-5C", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-6A", + "data_center": "FALSE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-6A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-6B", + "data_center": "FALSE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-6B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-7A", + "data_center": "FALSE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-7A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-7B", + "data_center": "FALSE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-7B", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-8A", + "data_center": "FALSE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-8A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-8B", + "data_center": "FALSE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-8B", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-1A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-1A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-1B", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-1B", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-2A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-2A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-2B", + "data_center": "FALSE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-2B", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-3A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-3A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-3B", + "data_center": "FALSE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-3B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-3C", + "data_center": "FALSE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-3C", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-4A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-4A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-4B", + "data_center": "FALSE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-4B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-4C", + "data_center": "FALSE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-4C", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-5A", + "data_center": "FALSE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-5A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-5B", + "data_center": "FALSE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-5B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-5C", + "data_center": "FALSE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-5C", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-6A", + "data_center": "FALSE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-6A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-6B", + "data_center": "FALSE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-6B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-7A", + "data_center": "FALSE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-7A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-7B", + "data_center": "FALSE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-7B", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-8A", + "data_center": "FALSE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-8A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-8B", + "data_center": "FALSE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-8B", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-1A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-1A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-1B", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-1B", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-2A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-2A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-2B", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-2B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-3A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-3A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-3B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-3B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-3C", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-3C", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-4A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-4A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-4B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-4B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-4C", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-4C", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-5A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-5A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-5B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-5B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-5C", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-5C", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-6A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-6A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-6B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-6B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-7A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-7A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-7B", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-7B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-8A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-8A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-8B", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-8B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-1A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-1A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-1B", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-1B", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-2A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-2A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-2B", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-2B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-3A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-3A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-3B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-3B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-3C", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-3C", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-4A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-4A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-4B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-4B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-4C", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-4C", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-5A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-5A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-5B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-5B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-5C", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-5C", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-6A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-6A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-6B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-6B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-7A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-7A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-7B", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-7B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-8A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-8A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-8B", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-8B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-1A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-1A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-1B", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-1B", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-2A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-2A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-2B", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-2B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-3A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-3A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-3B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-3B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-3C", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-3C", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-4A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-4A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-4B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-4B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-4C", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-4C", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-5A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-5A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-5B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-5B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-5C", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-5C", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-6A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-6A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-6B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-6B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-7A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-7A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-7B", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-7B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-8A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-8A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-8B", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-8B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-1A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-1A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-1B", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-1B", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-2A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-2A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-2B", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-2B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-3A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-3A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-3B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-3B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-3C", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-3C", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-4A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-4A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-4B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-4B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-4C", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-4C", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-5A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-5A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-5B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-5B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-5C", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-5C", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-6A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-6A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-6B", + "data_center": "TRUE", + "capacity_limit": 65000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-6B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-7A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-7A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-7B", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-7B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-8A", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-8A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-8B", + "data_center": "TRUE", + "capacity_limit": 135000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-8B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-0A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-0B", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-0A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-0B", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-0A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-0B", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-0A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-0B", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-0A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-0B", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-0A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 65, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-0B", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-0A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-0B", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-0A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-0B", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-0A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-0B", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-0A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-0B", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-0A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-0B", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-0A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-0B", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-1A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-1A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-1B", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-1B", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-2A", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-2A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-2B", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-2B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-3A", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-3A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-3B", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-3B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-3C", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-3C", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-4A", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-4A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-4B", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-4B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-4C", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-4C", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-5A", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-5A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-5B", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-5B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-5C", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-5C", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-6A", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-6A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-6B", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-6B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-7A", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-7A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-7B", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-7B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-8A", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-8A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-8B", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-8B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-1A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-1A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-1B", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-1B", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-2A", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-2A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-2B", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-2B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-3A", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-3A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-3B", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-3B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-3C", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-3C", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-4A", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-4A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-4B", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-4B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-4C", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-4C", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-5A", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-5A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-5B", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-5B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-5C", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-5C", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-6A", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-6A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-6B", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-6B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-7A", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-7A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-7B", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-7B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-8A", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-8A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-8B", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-8B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-0A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-0B", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-0A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-0B", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-0A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-0B", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-0A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-0B", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2016 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-1A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-1A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-1B", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-1B", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-2A", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-2A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-2B", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-2B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-3A", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-3A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-3B", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-3B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-3C", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-3C", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-4A", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-4A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-4B", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-4B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-4C", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-4C", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-5A", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-5A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-5B", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-5B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-5C", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-5C", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-6A", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-6A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-6B", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-6B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-7A", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-7A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-7B", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-7B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-8A", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-8A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-8B", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-8B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-1A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-1A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-1B", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-1B", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-2A", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-2A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-2B", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-2B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-3A", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-3A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-3B", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-3B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-3C", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-3C", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-4A", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-4A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-4B", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-4B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-4C", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-4C", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-5A", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-5A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-5B", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-5B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-5C", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-5C", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-6A", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-6A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 70, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-6B", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-6B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-7A", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-7A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-7B", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-7B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-8A", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-8A", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-8B", + "data_center": "TRUE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-8B", + "data_center": "FALSE", + "capacity_limit": 54000, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-0A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-0B", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-0A", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-0B", + "data_center": "FALSE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-0A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-0B", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-0A", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-0B", + "data_center": "TRUE", + "capacity_limit": null, + "fixed_dry_bulb_high_limit_shutoff_temp": 75, + "annotation": "90.1-2019 Table 6.5.1.1.3" + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/system_requirement_energy_recovery_90_1.csv b/data/openstudio_standards_data/database_files/system_requirement_energy_recovery_90_1.csv index a06d3844d7..862acf4361 100644 --- a/data/openstudio_standards_data/database_files/system_requirement_energy_recovery_90_1.csv +++ b/data/openstudio_standards_data/database_files/system_requirement_energy_recovery_90_1.csv @@ -1,409 +1,409 @@ template,climate_zone,under_8000_hours,nontransient_dwelling,percent_oa_0_to_10,percent_oa_10_to_20,percent_oa_20_to_30,percent_oa_30_to_40,percent_oa_40_to_50,percent_oa_50_to_60,percent_oa_60_to_70,percent_oa_70_to_80,percent_oa_greater_than_80,enthalpy_recovery_ratio_design_conditions,enthalpy_recovery_ratio,annotation -90.1-2010,ASHRAE 169-2006-1A,,,,,,5500,4500,3500,2000,1000,0,, -90.1-2010,ASHRAE 169-2006-1B,,,,,,,,26000,12000,5000,4000,, -90.1-2010,ASHRAE 169-2006-2A,,,,,,5500,4500,3500,2000,1000,0,, -90.1-2010,ASHRAE 169-2006-2B,,,,,,,,26000,12000,5000,4000,, -90.1-2010,ASHRAE 169-2006-3A,,,,,,5500,4500,3500,2000,1000,0,, -90.1-2010,ASHRAE 169-2006-3B,,,,,,,,,,5000,5000,, -90.1-2010,ASHRAE 169-2006-3C,,,,,,,,,,5000,5000,, -90.1-2010,ASHRAE 169-2006-4A,,,,,,5500,4500,3500,2000,1000,0,, -90.1-2010,ASHRAE 169-2006-4B,,,,,,,,,,5000,5000,, -90.1-2010,ASHRAE 169-2006-4C,,,,,,,,,,5000,5000,, -90.1-2010,ASHRAE 169-2006-5A,,,,,,5500,4500,3500,2000,1000,0,, -90.1-2010,ASHRAE 169-2006-5B,,,,,,,,,,5000,5000,, -90.1-2010,ASHRAE 169-2006-5C,,,,,,,,26000,12000,5000,4000,, -90.1-2010,ASHRAE 169-2006-6A,,,,,,5500,4500,3500,2000,1000,0,, -90.1-2010,ASHRAE 169-2006-6B,,,,,,11000,5500,4500,3500,2500,1500,, -90.1-2010,ASHRAE 169-2006-7A,,,,,,2500,1000,0,0,0,0,, -90.1-2010,ASHRAE 169-2006-7B,,,,,,2500,1000,0,0,0,0,, -90.1-2010,ASHRAE 169-2006-8A,,,,,,2500,1000,0,0,0,0,, -90.1-2010,ASHRAE 169-2006-8B,,,,,,2500,1000,0,0,0,0,, -90.1-2010,ASHRAE 169-2013-1A,,,,,,5500,4500,3500,2000,1000,0,, -90.1-2010,ASHRAE 169-2013-1B,,,,,,,,26000,12000,5000,4000,, -90.1-2010,ASHRAE 169-2013-2A,,,,,,5500,4500,3500,2000,1000,0,, -90.1-2010,ASHRAE 169-2013-2B,,,,,,,,26000,12000,5000,4000,, -90.1-2010,ASHRAE 169-2013-3A,,,,,,5500,4500,3500,2000,1000,0,, -90.1-2010,ASHRAE 169-2013-3B,,,,,,,,,,5000,5000,, -90.1-2010,ASHRAE 169-2013-3C,,,,,,,,,,5000,5000,, -90.1-2010,ASHRAE 169-2013-4A,,,,,,5500,4500,3500,2000,1000,0,, -90.1-2010,ASHRAE 169-2013-4B,,,,,,,,,,5000,5000,, -90.1-2010,ASHRAE 169-2013-4C,,,,,,,,,,5000,5000,, -90.1-2010,ASHRAE 169-2013-5A,,,,,,5500,4500,3500,2000,1000,0,, -90.1-2010,ASHRAE 169-2013-5B,,,,,,,,,,5000,5000,, -90.1-2010,ASHRAE 169-2013-5C,,,,,,,,26000,12000,5000,4000,, -90.1-2010,ASHRAE 169-2013-6A,,,,,,5500,4500,3500,2000,1000,0,, -90.1-2010,ASHRAE 169-2013-6B,,,,,,11000,5500,4500,3500,2500,1500,, -90.1-2010,ASHRAE 169-2013-7A,,,,,,2500,1000,0,0,0,0,, -90.1-2010,ASHRAE 169-2013-7B,,,,,,2500,1000,0,0,0,0,, -90.1-2010,ASHRAE 169-2013-8A,,,,,,2500,1000,0,0,0,0,, -90.1-2010,ASHRAE 169-2013-8B,,,,,,2500,1000,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-1A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, -90.1-2013,ASHRAE 169-2006-1A,FALSE,,,2500,2000,1000,500,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-1B,TRUE,,,,,,,26000,12000,5000,4000,, -90.1-2013,ASHRAE 169-2006-1B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, -90.1-2013,ASHRAE 169-2006-2A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, -90.1-2013,ASHRAE 169-2006-2A,FALSE,,,2500,2000,1000,500,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-2B,TRUE,,,,,,,26000,12000,5000,4000,, -90.1-2013,ASHRAE 169-2006-2B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, -90.1-2013,ASHRAE 169-2006-3A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, -90.1-2013,ASHRAE 169-2006-3A,FALSE,,,2500,2000,1000,500,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-3B,TRUE,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2006-3B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, -90.1-2013,ASHRAE 169-2006-3C,TRUE,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2006-3C,FALSE,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2006-4A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, -90.1-2013,ASHRAE 169-2006-4A,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-4B,TRUE,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2006-4B,FALSE,,,2500,2000,1000,500,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-4C,TRUE,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2006-4C,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, -90.1-2013,ASHRAE 169-2006-5A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, -90.1-2013,ASHRAE 169-2006-5A,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-5B,TRUE,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2006-5B,FALSE,,,2500,2000,1000,500,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-5C,TRUE,,,,,,,26000,12000,5000,4000,, -90.1-2013,ASHRAE 169-2006-5C,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, -90.1-2013,ASHRAE 169-2006-6A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, -90.1-2013,ASHRAE 169-2006-6A,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-6B,TRUE,,,28000,26500,11000,5500,4500,3500,2500,1500,, -90.1-2013,ASHRAE 169-2006-6B,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-7A,TRUE,,,4500,4000,2500,1000,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-7A,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-7B,TRUE,,,4500,4000,2500,1000,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-7B,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-8A,TRUE,,,4500,4000,2500,1000,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-8A,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-8B,TRUE,,,4500,4000,2500,1000,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-8B,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-1A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, -90.1-2013,ASHRAE 169-2013-1A,FALSE,,,2500,2000,1000,500,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-1B,TRUE,,,,,,,26000,12000,5000,4000,, -90.1-2013,ASHRAE 169-2013-1B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, -90.1-2013,ASHRAE 169-2013-2A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, -90.1-2013,ASHRAE 169-2013-2A,FALSE,,,2500,2000,1000,500,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-2B,TRUE,,,,,,,26000,12000,5000,4000,, -90.1-2013,ASHRAE 169-2013-2B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, -90.1-2013,ASHRAE 169-2013-3A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, -90.1-2013,ASHRAE 169-2013-3A,FALSE,,,2500,2000,1000,500,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-3B,TRUE,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2013-3B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, -90.1-2013,ASHRAE 169-2013-3C,TRUE,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2013-3C,FALSE,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2013-4A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, -90.1-2013,ASHRAE 169-2013-4A,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-4B,TRUE,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2013-4B,FALSE,,,2500,2000,1000,500,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-4C,TRUE,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2013-4C,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, -90.1-2013,ASHRAE 169-2013-5A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, -90.1-2013,ASHRAE 169-2013-5A,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-5B,TRUE,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2013-5B,FALSE,,,2500,2000,1000,500,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-5C,TRUE,,,,,,,26000,12000,5000,4000,, -90.1-2013,ASHRAE 169-2013-5C,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, -90.1-2013,ASHRAE 169-2013-6A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, -90.1-2013,ASHRAE 169-2013-6A,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-6B,TRUE,,,28000,26500,11000,5500,4500,3500,2500,1500,, -90.1-2013,ASHRAE 169-2013-6B,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-7A,TRUE,,,4500,4000,2500,1000,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-7A,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-7B,TRUE,,,4500,4000,2500,1000,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-7B,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-8A,TRUE,,,4500,4000,2500,1000,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-8A,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-8B,TRUE,,,4500,4000,2500,1000,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-8B,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2016,ASHRAE 169-2006-1A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-1A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-1B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-1B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-2A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-2A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-2B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-2B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-3A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-3A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-3B,TRUE,,,,,,,,,,,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-3B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-3C,TRUE,,,,,,,,,,,Heating,0.5 -90.1-2016,ASHRAE 169-2006-3C,FALSE,,,,,,,,,,,Heating,0.5 -90.1-2016,ASHRAE 169-2006-4A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-4A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-4B,TRUE,,,,,,,,,,,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-4B,TRUE,,,,,,,,,,,Heating,0.5 -90.1-2016,ASHRAE 169-2006-4B,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-4B,FALSE,,,2500,2000,1000,500,140,120,100,80,Heating,0.5 -90.1-2016,ASHRAE 169-2006-4C,TRUE,,,,,,,,,,,Heating,0.5 -90.1-2016,ASHRAE 169-2006-4C,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 -90.1-2016,ASHRAE 169-2006-5A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-5A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-5B,TRUE,,,,,,,,,,,Heating,0.5 -90.1-2016,ASHRAE 169-2006-5B,FALSE,,,2500,2000,1000,500,140,120,100,80,Heating,0.5 -90.1-2016,ASHRAE 169-2006-5C,TRUE,,,,,,,26000,12000,5000,4000,Heating,0.5 -90.1-2016,ASHRAE 169-2006-5C,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 -90.1-2016,ASHRAE 169-2006-6A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-6A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-6B,TRUE,,,28000,26500,11000,5500,4500,3500,2500,1500,Heating,0.5 -90.1-2016,ASHRAE 169-2006-6B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2016,ASHRAE 169-2006-7A,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2016,ASHRAE 169-2006-7A,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2016,ASHRAE 169-2006-7B,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2016,ASHRAE 169-2006-7B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2016,ASHRAE 169-2006-8A,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2016,ASHRAE 169-2006-8A,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2016,ASHRAE 169-2006-8B,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2016,ASHRAE 169-2006-8B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2016,ASHRAE 169-2013-1A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-1A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-1B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-1B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-2A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-2A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-2B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-2B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-3A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-3A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-3B,TRUE,,,,,,,,,,,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-3B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-3C,TRUE,,,,,,,,,,,Heating,0.5 -90.1-2016,ASHRAE 169-2013-3C,FALSE,,,,,,,,,,,Heating,0.5 -90.1-2016,ASHRAE 169-2013-4A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-4A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-4B,TRUE,,,,,,,,,,,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-4B,TRUE,,,,,,,,,,,Heating,0.5 -90.1-2016,ASHRAE 169-2013-4B,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-4B,FALSE,,,2500,2000,1000,500,140,120,100,80,Heating,0.5 -90.1-2016,ASHRAE 169-2013-4C,TRUE,,,,,,,,,,,Heating,0.5 -90.1-2016,ASHRAE 169-2013-4C,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 -90.1-2016,ASHRAE 169-2013-5A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-5A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-5B,TRUE,,,,,,,,,,,Heating,0.5 -90.1-2016,ASHRAE 169-2013-5B,FALSE,,,2500,2000,1000,500,140,120,100,80,Heating,0.5 -90.1-2016,ASHRAE 169-2013-5C,TRUE,,,,,,,26000,12000,5000,4000,Heating,0.5 -90.1-2016,ASHRAE 169-2013-5C,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 -90.1-2016,ASHRAE 169-2013-6A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-6A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-6B,TRUE,,,28000,26500,11000,5500,4500,3500,2500,1500,Heating,0.5 -90.1-2016,ASHRAE 169-2013-6B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2016,ASHRAE 169-2013-7A,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2016,ASHRAE 169-2013-7A,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2016,ASHRAE 169-2013-7B,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2016,ASHRAE 169-2013-7B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2016,ASHRAE 169-2013-8A,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2016,ASHRAE 169-2013-8A,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2016,ASHRAE 169-2013-8B,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2016,ASHRAE 169-2013-8B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2006-1A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-1A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-1A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-1A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-1B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-1B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-1B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-1B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-2A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-2A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-2A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-2A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-2B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-2B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-2B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-2B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-3A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-3A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-3A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 -90.1-2019,ASHRAE 169-2006-3A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-3A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-3A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5 -90.1-2019,ASHRAE 169-2006-3B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-3B,TRUE,FALSE,,,,,,,,,,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-3B,TRUE,FALSE,,,,,,,,,,Heating,0.5 -90.1-2019,ASHRAE 169-2006-3B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-3B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-3B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 -90.1-2019,ASHRAE 169-2006-3C,TRUE,TRUE,,,,,,,,,,, -90.1-2019,ASHRAE 169-2006-3C,TRUE,FALSE,,,,,,,,,,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-3C,TRUE,FALSE,,,,,,,,,,Heating,0.5 -90.1-2019,ASHRAE 169-2006-3C,FALSE,TRUE,,,,,,,,,,, -90.1-2019,ASHRAE 169-2006-3C,FALSE,FALSE,,,,,,,,,,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-3C,FALSE,FALSE,,,,,,,,,,Heating,0.5 -90.1-2019,ASHRAE 169-2006-4A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-4A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-4A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 -90.1-2019,ASHRAE 169-2006-4A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-4A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-4A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2006-4B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-4B,TRUE,FALSE,,,,,,,,,,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-4B,TRUE,FALSE,,,,,,,,,,Heating,0.5 -90.1-2019,ASHRAE 169-2006-4B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-4B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-4B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5 -90.1-2019,ASHRAE 169-2006-4C,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-4C,TRUE,FALSE,,,,,,,,,,Heating,0.5 -90.1-2019,ASHRAE 169-2006-4C,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-4C,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 -90.1-2019,ASHRAE 169-2006-5A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-5A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-5A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 -90.1-2019,ASHRAE 169-2006-5A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-5A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-5A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2006-5B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-5B,TRUE,FALSE,,,,,,,,,,Heating,0.5 -90.1-2019,ASHRAE 169-2006-5B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-5B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5 -90.1-2019,ASHRAE 169-2006-5C,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-5C,TRUE,FALSE,,,,,,26000,12000,5000,4000,Heating,0.5 -90.1-2019,ASHRAE 169-2006-5C,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-5C,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 -90.1-2019,ASHRAE 169-2006-6A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-6A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-6A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 -90.1-2019,ASHRAE 169-2006-6A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-6A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-6A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2006-6B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-6B,TRUE,FALSE,,28000,26500,11000,5500,4500,3500,2500,1500,Heating,0.5 -90.1-2019,ASHRAE 169-2006-6B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-6B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2006-7A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-7A,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2019,ASHRAE 169-2006-7A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-7A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2006-7B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-7B,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2019,ASHRAE 169-2006-7B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-7B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2006-8A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-8A,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2019,ASHRAE 169-2006-8A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-8A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2006-8B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-8B,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2019,ASHRAE 169-2006-8B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-8B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2013-1A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-1A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-1A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-1A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-1B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-1B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-1B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-1B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-2A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-2A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-2A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-2A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-2B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-2B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-2B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-2B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-3A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-3A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-3A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 -90.1-2019,ASHRAE 169-2013-3A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-3A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-3A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5 -90.1-2019,ASHRAE 169-2013-3B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-3B,TRUE,FALSE,,,,,,,,,,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-3B,TRUE,FALSE,,,,,,,,,,Heating,0.5 -90.1-2019,ASHRAE 169-2013-3B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-3B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-3B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 -90.1-2019,ASHRAE 169-2013-3C,TRUE,TRUE,,,,,,,,,,, -90.1-2019,ASHRAE 169-2013-3C,TRUE,FALSE,,,,,,,,,,Heating,0.5 -90.1-2019,ASHRAE 169-2013-3C,FALSE,TRUE,,,,,,,,,,, -90.1-2019,ASHRAE 169-2013-3C,FALSE,FALSE,,,,,,,,,,Heating,0.5 -90.1-2019,ASHRAE 169-2013-4A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-4A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-4A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 -90.1-2019,ASHRAE 169-2013-4A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-4A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-4A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2013-4B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-4B,TRUE,FALSE,,,,,,,,,,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-4B,TRUE,FALSE,,,,,,,,,,Heating,0.5 -90.1-2019,ASHRAE 169-2013-4B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-4B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-4B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5 -90.1-2019,ASHRAE 169-2013-4C,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-4C,TRUE,FALSE,,,,,,,,,,Heating,0.5 -90.1-2019,ASHRAE 169-2013-4C,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-4C,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 -90.1-2019,ASHRAE 169-2013-5A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-5A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-5A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 -90.1-2019,ASHRAE 169-2013-5A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-5A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-5A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2013-5B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-5B,TRUE,FALSE,,,,,,,,,,Heating,0.5 -90.1-2019,ASHRAE 169-2013-5B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-5B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5 -90.1-2019,ASHRAE 169-2013-5C,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-5C,TRUE,FALSE,,,,,,26000,12000,5000,4000,Heating,0.5 -90.1-2019,ASHRAE 169-2013-5C,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-5C,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 -90.1-2019,ASHRAE 169-2013-6A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-6A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-6A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 -90.1-2019,ASHRAE 169-2013-6A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-6A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-6A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2013-6B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-6B,TRUE,FALSE,,28000,26500,11000,5500,4500,3500,2500,1500,Heating,0.5 -90.1-2019,ASHRAE 169-2013-6B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-6B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2013-7A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-7A,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2019,ASHRAE 169-2013-7A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-7A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2013-7B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-7B,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2019,ASHRAE 169-2013-7B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-7B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2013-8A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-8A,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2019,ASHRAE 169-2013-8A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-8A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2013-8B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-8B,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2019,ASHRAE 169-2013-8B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-8B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2010,ASHRAE 169-2006-0A,,,,,,5500,4500,3500,2000,1000,0,, -90.1-2010,ASHRAE 169-2006-0B,,,,,,,,26000,12000,5000,4000,, -90.1-2010,ASHRAE 169-2013-0A,,,,,,5500,4500,3500,2000,1000,0,, -90.1-2010,ASHRAE 169-2013-0B,,,,,,,,26000,12000,5000,4000,, -90.1-2013,ASHRAE 169-2006-0A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, -90.1-2013,ASHRAE 169-2006-0A,FALSE,,,2500,2000,1000,500,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-0B,TRUE,,,,,,,26000,12000,5000,4000,, -90.1-2013,ASHRAE 169-2006-0B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, -90.1-2013,ASHRAE 169-2013-0A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, -90.1-2013,ASHRAE 169-2013-0A,FALSE,,,2500,2000,1000,500,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-0B,TRUE,,,,,,,26000,12000,5000,4000,, -90.1-2013,ASHRAE 169-2013-0B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, -90.1-2016,ASHRAE 169-2006-0A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-0A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-0B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-0B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-0A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-0A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-0B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-0B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-0A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-0A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-0A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-0A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-0B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-0B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-0B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-0B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-0A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-0A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-0A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-0A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-0B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-0B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-0B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-0B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 +90.1-2010,ASHRAE 169-2006-1A,,,,,,5500,4500,3500,2000,1000,0,,, +90.1-2010,ASHRAE 169-2006-1B,,,,,,,,26000,12000,5000,4000,,, +90.1-2010,ASHRAE 169-2006-2A,,,,,,5500,4500,3500,2000,1000,0,,, +90.1-2010,ASHRAE 169-2006-2B,,,,,,,,26000,12000,5000,4000,,, +90.1-2010,ASHRAE 169-2006-3A,,,,,,5500,4500,3500,2000,1000,0,,, +90.1-2010,ASHRAE 169-2006-3B,,,,,,,,,,5000,5000,,, +90.1-2010,ASHRAE 169-2006-3C,,,,,,,,,,5000,5000,,, +90.1-2010,ASHRAE 169-2006-4A,,,,,,5500,4500,3500,2000,1000,0,,, +90.1-2010,ASHRAE 169-2006-4B,,,,,,,,,,5000,5000,,, +90.1-2010,ASHRAE 169-2006-4C,,,,,,,,,,5000,5000,,, +90.1-2010,ASHRAE 169-2006-5A,,,,,,5500,4500,3500,2000,1000,0,,, +90.1-2010,ASHRAE 169-2006-5B,,,,,,,,,,5000,5000,,, +90.1-2010,ASHRAE 169-2006-5C,,,,,,,,26000,12000,5000,4000,,, +90.1-2010,ASHRAE 169-2006-6A,,,,,,5500,4500,3500,2000,1000,0,,, +90.1-2010,ASHRAE 169-2006-6B,,,,,,11000,5500,4500,3500,2500,1500,,, +90.1-2010,ASHRAE 169-2006-7A,,,,,,2500,1000,0,0,0,0,,, +90.1-2010,ASHRAE 169-2006-7B,,,,,,2500,1000,0,0,0,0,,, +90.1-2010,ASHRAE 169-2006-8A,,,,,,2500,1000,0,0,0,0,,, +90.1-2010,ASHRAE 169-2006-8B,,,,,,2500,1000,0,0,0,0,,, +90.1-2010,ASHRAE 169-2013-1A,,,,,,5500,4500,3500,2000,1000,0,,, +90.1-2010,ASHRAE 169-2013-1B,,,,,,,,26000,12000,5000,4000,,, +90.1-2010,ASHRAE 169-2013-2A,,,,,,5500,4500,3500,2000,1000,0,,, +90.1-2010,ASHRAE 169-2013-2B,,,,,,,,26000,12000,5000,4000,,, +90.1-2010,ASHRAE 169-2013-3A,,,,,,5500,4500,3500,2000,1000,0,,, +90.1-2010,ASHRAE 169-2013-3B,,,,,,,,,,5000,5000,,, +90.1-2010,ASHRAE 169-2013-3C,,,,,,,,,,5000,5000,,, +90.1-2010,ASHRAE 169-2013-4A,,,,,,5500,4500,3500,2000,1000,0,,, +90.1-2010,ASHRAE 169-2013-4B,,,,,,,,,,5000,5000,,, +90.1-2010,ASHRAE 169-2013-4C,,,,,,,,,,5000,5000,,, +90.1-2010,ASHRAE 169-2013-5A,,,,,,5500,4500,3500,2000,1000,0,,, +90.1-2010,ASHRAE 169-2013-5B,,,,,,,,,,5000,5000,,, +90.1-2010,ASHRAE 169-2013-5C,,,,,,,,26000,12000,5000,4000,,, +90.1-2010,ASHRAE 169-2013-6A,,,,,,5500,4500,3500,2000,1000,0,,, +90.1-2010,ASHRAE 169-2013-6B,,,,,,11000,5500,4500,3500,2500,1500,,, +90.1-2010,ASHRAE 169-2013-7A,,,,,,2500,1000,0,0,0,0,,, +90.1-2010,ASHRAE 169-2013-7B,,,,,,2500,1000,0,0,0,0,,, +90.1-2010,ASHRAE 169-2013-8A,,,,,,2500,1000,0,0,0,0,,, +90.1-2010,ASHRAE 169-2013-8B,,,,,,2500,1000,0,0,0,0,,, +90.1-2013,ASHRAE 169-2006-1A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,,, +90.1-2013,ASHRAE 169-2006-1A,FALSE,,,2500,2000,1000,500,0,0,0,0,,, +90.1-2013,ASHRAE 169-2006-1B,TRUE,,,,,,,26000,12000,5000,4000,,, +90.1-2013,ASHRAE 169-2006-1B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,,, +90.1-2013,ASHRAE 169-2006-2A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,,, +90.1-2013,ASHRAE 169-2006-2A,FALSE,,,2500,2000,1000,500,0,0,0,0,,, +90.1-2013,ASHRAE 169-2006-2B,TRUE,,,,,,,26000,12000,5000,4000,,, +90.1-2013,ASHRAE 169-2006-2B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,,, +90.1-2013,ASHRAE 169-2006-3A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,,, +90.1-2013,ASHRAE 169-2006-3A,FALSE,,,2500,2000,1000,500,0,0,0,0,,, +90.1-2013,ASHRAE 169-2006-3B,TRUE,,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2006-3B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,,, +90.1-2013,ASHRAE 169-2006-3C,TRUE,,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2006-3C,FALSE,,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2006-4A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,,, +90.1-2013,ASHRAE 169-2006-4A,FALSE,,,0,0,0,0,0,0,0,0,,, +90.1-2013,ASHRAE 169-2006-4B,TRUE,,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2006-4B,FALSE,,,2500,2000,1000,500,0,0,0,0,,, +90.1-2013,ASHRAE 169-2006-4C,TRUE,,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2006-4C,FALSE,,,,19500,9000,5000,4000,3000,1500,0,,, +90.1-2013,ASHRAE 169-2006-5A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,,, +90.1-2013,ASHRAE 169-2006-5A,FALSE,,,0,0,0,0,0,0,0,0,,, +90.1-2013,ASHRAE 169-2006-5B,TRUE,,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2006-5B,FALSE,,,2500,2000,1000,500,0,0,0,0,,, +90.1-2013,ASHRAE 169-2006-5C,TRUE,,,,,,,26000,12000,5000,4000,,, +90.1-2013,ASHRAE 169-2006-5C,FALSE,,,,19500,9000,5000,4000,3000,1500,0,,, +90.1-2013,ASHRAE 169-2006-6A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,,, +90.1-2013,ASHRAE 169-2006-6A,FALSE,,,0,0,0,0,0,0,0,0,,, +90.1-2013,ASHRAE 169-2006-6B,TRUE,,,28000,26500,11000,5500,4500,3500,2500,1500,,, +90.1-2013,ASHRAE 169-2006-6B,FALSE,,,0,0,0,0,0,0,0,0,,, +90.1-2013,ASHRAE 169-2006-7A,TRUE,,,4500,4000,2500,1000,0,0,0,0,,, +90.1-2013,ASHRAE 169-2006-7A,FALSE,,,0,0,0,0,0,0,0,0,,, +90.1-2013,ASHRAE 169-2006-7B,TRUE,,,4500,4000,2500,1000,0,0,0,0,,, +90.1-2013,ASHRAE 169-2006-7B,FALSE,,,0,0,0,0,0,0,0,0,,, +90.1-2013,ASHRAE 169-2006-8A,TRUE,,,4500,4000,2500,1000,0,0,0,0,,, +90.1-2013,ASHRAE 169-2006-8A,FALSE,,,0,0,0,0,0,0,0,0,,, +90.1-2013,ASHRAE 169-2006-8B,TRUE,,,4500,4000,2500,1000,0,0,0,0,,, +90.1-2013,ASHRAE 169-2006-8B,FALSE,,,0,0,0,0,0,0,0,0,,, +90.1-2013,ASHRAE 169-2013-1A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,,, +90.1-2013,ASHRAE 169-2013-1A,FALSE,,,2500,2000,1000,500,0,0,0,0,,, +90.1-2013,ASHRAE 169-2013-1B,TRUE,,,,,,,26000,12000,5000,4000,,, +90.1-2013,ASHRAE 169-2013-1B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,,, +90.1-2013,ASHRAE 169-2013-2A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,,, +90.1-2013,ASHRAE 169-2013-2A,FALSE,,,2500,2000,1000,500,0,0,0,0,,, +90.1-2013,ASHRAE 169-2013-2B,TRUE,,,,,,,26000,12000,5000,4000,,, +90.1-2013,ASHRAE 169-2013-2B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,,, +90.1-2013,ASHRAE 169-2013-3A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,,, +90.1-2013,ASHRAE 169-2013-3A,FALSE,,,2500,2000,1000,500,0,0,0,0,,, +90.1-2013,ASHRAE 169-2013-3B,TRUE,,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2013-3B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,,, +90.1-2013,ASHRAE 169-2013-3C,TRUE,,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2013-3C,FALSE,,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2013-4A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,,, +90.1-2013,ASHRAE 169-2013-4A,FALSE,,,0,0,0,0,0,0,0,0,,, +90.1-2013,ASHRAE 169-2013-4B,TRUE,,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2013-4B,FALSE,,,2500,2000,1000,500,0,0,0,0,,, +90.1-2013,ASHRAE 169-2013-4C,TRUE,,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2013-4C,FALSE,,,,19500,9000,5000,4000,3000,1500,0,,, +90.1-2013,ASHRAE 169-2013-5A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,,, +90.1-2013,ASHRAE 169-2013-5A,FALSE,,,0,0,0,0,0,0,0,0,,, +90.1-2013,ASHRAE 169-2013-5B,TRUE,,,,,,,,,,,,, +90.1-2013,ASHRAE 169-2013-5B,FALSE,,,2500,2000,1000,500,0,0,0,0,,, +90.1-2013,ASHRAE 169-2013-5C,TRUE,,,,,,,26000,12000,5000,4000,,, +90.1-2013,ASHRAE 169-2013-5C,FALSE,,,,19500,9000,5000,4000,3000,1500,0,,, +90.1-2013,ASHRAE 169-2013-6A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,,, +90.1-2013,ASHRAE 169-2013-6A,FALSE,,,0,0,0,0,0,0,0,0,,, +90.1-2013,ASHRAE 169-2013-6B,TRUE,,,28000,26500,11000,5500,4500,3500,2500,1500,,, +90.1-2013,ASHRAE 169-2013-6B,FALSE,,,0,0,0,0,0,0,0,0,,, +90.1-2013,ASHRAE 169-2013-7A,TRUE,,,4500,4000,2500,1000,0,0,0,0,,, +90.1-2013,ASHRAE 169-2013-7A,FALSE,,,0,0,0,0,0,0,0,0,,, +90.1-2013,ASHRAE 169-2013-7B,TRUE,,,4500,4000,2500,1000,0,0,0,0,,, +90.1-2013,ASHRAE 169-2013-7B,FALSE,,,0,0,0,0,0,0,0,0,,, +90.1-2013,ASHRAE 169-2013-8A,TRUE,,,4500,4000,2500,1000,0,0,0,0,,, +90.1-2013,ASHRAE 169-2013-8A,FALSE,,,0,0,0,0,0,0,0,0,,, +90.1-2013,ASHRAE 169-2013-8B,TRUE,,,4500,4000,2500,1000,0,0,0,0,,, +90.1-2013,ASHRAE 169-2013-8B,FALSE,,,0,0,0,0,0,0,0,0,,, +90.1-2016,ASHRAE 169-2006-1A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, +90.1-2016,ASHRAE 169-2006-1A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, +90.1-2016,ASHRAE 169-2006-1B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5, +90.1-2016,ASHRAE 169-2006-1B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, +90.1-2016,ASHRAE 169-2006-2A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, +90.1-2016,ASHRAE 169-2006-2A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, +90.1-2016,ASHRAE 169-2006-2B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5, +90.1-2016,ASHRAE 169-2006-2B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, +90.1-2016,ASHRAE 169-2006-3A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, +90.1-2016,ASHRAE 169-2006-3A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, +90.1-2016,ASHRAE 169-2006-3B,TRUE,,,,,,,,,,,Cooling,0.5, +90.1-2016,ASHRAE 169-2006-3B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, +90.1-2016,ASHRAE 169-2006-3C,TRUE,,,,,,,,,,,Heating,0.5, +90.1-2016,ASHRAE 169-2006-3C,FALSE,,,,,,,,,,,Heating,0.5, +90.1-2016,ASHRAE 169-2006-4A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, +90.1-2016,ASHRAE 169-2006-4A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5, +90.1-2016,ASHRAE 169-2006-4B,TRUE,,,,,,,,,,,Cooling,0.5, +90.1-2016,ASHRAE 169-2006-4B,TRUE,,,,,,,,,,,Heating,0.5, +90.1-2016,ASHRAE 169-2006-4B,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, +90.1-2016,ASHRAE 169-2006-4B,FALSE,,,2500,2000,1000,500,140,120,100,80,Heating,0.5, +90.1-2016,ASHRAE 169-2006-4C,TRUE,,,,,,,,,,,Heating,0.5, +90.1-2016,ASHRAE 169-2006-4C,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5, +90.1-2016,ASHRAE 169-2006-5A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, +90.1-2016,ASHRAE 169-2006-5A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5, +90.1-2016,ASHRAE 169-2006-5B,TRUE,,,,,,,,,,,Heating,0.5, +90.1-2016,ASHRAE 169-2006-5B,FALSE,,,2500,2000,1000,500,140,120,100,80,Heating,0.5, +90.1-2016,ASHRAE 169-2006-5C,TRUE,,,,,,,26000,12000,5000,4000,Heating,0.5, +90.1-2016,ASHRAE 169-2006-5C,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5, +90.1-2016,ASHRAE 169-2006-6A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, +90.1-2016,ASHRAE 169-2006-6A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5, +90.1-2016,ASHRAE 169-2006-6B,TRUE,,,28000,26500,11000,5500,4500,3500,2500,1500,Heating,0.5, +90.1-2016,ASHRAE 169-2006-6B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5, +90.1-2016,ASHRAE 169-2006-7A,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, +90.1-2016,ASHRAE 169-2006-7A,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5, +90.1-2016,ASHRAE 169-2006-7B,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, +90.1-2016,ASHRAE 169-2006-7B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5, +90.1-2016,ASHRAE 169-2006-8A,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, +90.1-2016,ASHRAE 169-2006-8A,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5, +90.1-2016,ASHRAE 169-2006-8B,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, +90.1-2016,ASHRAE 169-2006-8B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5, +90.1-2016,ASHRAE 169-2013-1A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, +90.1-2016,ASHRAE 169-2013-1A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, +90.1-2016,ASHRAE 169-2013-1B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5, +90.1-2016,ASHRAE 169-2013-1B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, +90.1-2016,ASHRAE 169-2013-2A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, +90.1-2016,ASHRAE 169-2013-2A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, +90.1-2016,ASHRAE 169-2013-2B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5, +90.1-2016,ASHRAE 169-2013-2B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, +90.1-2016,ASHRAE 169-2013-3A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, +90.1-2016,ASHRAE 169-2013-3A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, +90.1-2016,ASHRAE 169-2013-3B,TRUE,,,,,,,,,,,Cooling,0.5, +90.1-2016,ASHRAE 169-2013-3B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, +90.1-2016,ASHRAE 169-2013-3C,TRUE,,,,,,,,,,,Heating,0.5, +90.1-2016,ASHRAE 169-2013-3C,FALSE,,,,,,,,,,,Heating,0.5, +90.1-2016,ASHRAE 169-2013-4A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, +90.1-2016,ASHRAE 169-2013-4A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5, +90.1-2016,ASHRAE 169-2013-4B,TRUE,,,,,,,,,,,Cooling,0.5, +90.1-2016,ASHRAE 169-2013-4B,TRUE,,,,,,,,,,,Heating,0.5, +90.1-2016,ASHRAE 169-2013-4B,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, +90.1-2016,ASHRAE 169-2013-4B,FALSE,,,2500,2000,1000,500,140,120,100,80,Heating,0.5, +90.1-2016,ASHRAE 169-2013-4C,TRUE,,,,,,,,,,,Heating,0.5, +90.1-2016,ASHRAE 169-2013-4C,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5, +90.1-2016,ASHRAE 169-2013-5A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, +90.1-2016,ASHRAE 169-2013-5A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5, +90.1-2016,ASHRAE 169-2013-5B,TRUE,,,,,,,,,,,Heating,0.5, +90.1-2016,ASHRAE 169-2013-5B,FALSE,,,2500,2000,1000,500,140,120,100,80,Heating,0.5, +90.1-2016,ASHRAE 169-2013-5C,TRUE,,,,,,,26000,12000,5000,4000,Heating,0.5, +90.1-2016,ASHRAE 169-2013-5C,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5, +90.1-2016,ASHRAE 169-2013-6A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, +90.1-2016,ASHRAE 169-2013-6A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5, +90.1-2016,ASHRAE 169-2013-6B,TRUE,,,28000,26500,11000,5500,4500,3500,2500,1500,Heating,0.5, +90.1-2016,ASHRAE 169-2013-6B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5, +90.1-2016,ASHRAE 169-2013-7A,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, +90.1-2016,ASHRAE 169-2013-7A,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5, +90.1-2016,ASHRAE 169-2013-7B,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, +90.1-2016,ASHRAE 169-2013-7B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5, +90.1-2016,ASHRAE 169-2013-8A,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, +90.1-2016,ASHRAE 169-2013-8A,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5, +90.1-2016,ASHRAE 169-2013-8B,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, +90.1-2016,ASHRAE 169-2013-8B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5, +90.1-2019,ASHRAE 169-2006-1A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-1A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-1A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-1A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-1B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-1B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-1B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-1B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-2A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-2A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-2A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-2A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-2B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-2B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-2B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-2B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-3A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-3A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-3A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5, +90.1-2019,ASHRAE 169-2006-3A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-3A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-3A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5, +90.1-2019,ASHRAE 169-2006-3B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-3B,TRUE,FALSE,,,,,,,,,,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-3B,TRUE,FALSE,,,,,,,,,,Heating,0.5, +90.1-2019,ASHRAE 169-2006-3B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-3B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-3B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5, +90.1-2019,ASHRAE 169-2006-3C,TRUE,TRUE,,,,,,,,,,,, +90.1-2019,ASHRAE 169-2006-3C,TRUE,FALSE,,,,,,,,,,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-3C,TRUE,FALSE,,,,,,,,,,Heating,0.5, +90.1-2019,ASHRAE 169-2006-3C,FALSE,TRUE,,,,,,,,,,,, +90.1-2019,ASHRAE 169-2006-3C,FALSE,FALSE,,,,,,,,,,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-3C,FALSE,FALSE,,,,,,,,,,Heating,0.5, +90.1-2019,ASHRAE 169-2006-4A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2006-4A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-4A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5, +90.1-2019,ASHRAE 169-2006-4A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2006-4A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-4A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, +90.1-2019,ASHRAE 169-2006-4B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2006-4B,TRUE,FALSE,,,,,,,,,,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-4B,TRUE,FALSE,,,,,,,,,,Heating,0.5, +90.1-2019,ASHRAE 169-2006-4B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2006-4B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-4B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5, +90.1-2019,ASHRAE 169-2006-4C,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2006-4C,TRUE,FALSE,,,,,,,,,,Heating,0.5, +90.1-2019,ASHRAE 169-2006-4C,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2006-4C,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5, +90.1-2019,ASHRAE 169-2006-5A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2006-5A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-5A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5, +90.1-2019,ASHRAE 169-2006-5A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2006-5A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-5A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, +90.1-2019,ASHRAE 169-2006-5B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2006-5B,TRUE,FALSE,,,,,,,,,,Heating,0.5, +90.1-2019,ASHRAE 169-2006-5B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2006-5B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5, +90.1-2019,ASHRAE 169-2006-5C,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2006-5C,TRUE,FALSE,,,,,,26000,12000,5000,4000,Heating,0.5, +90.1-2019,ASHRAE 169-2006-5C,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2006-5C,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5, +90.1-2019,ASHRAE 169-2006-6A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2006-6A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-6A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5, +90.1-2019,ASHRAE 169-2006-6A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2006-6A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-6A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, +90.1-2019,ASHRAE 169-2006-6B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2006-6B,TRUE,FALSE,,28000,26500,11000,5500,4500,3500,2500,1500,Heating,0.5, +90.1-2019,ASHRAE 169-2006-6B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2006-6B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, +90.1-2019,ASHRAE 169-2006-7A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2006-7A,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, +90.1-2019,ASHRAE 169-2006-7A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2006-7A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, +90.1-2019,ASHRAE 169-2006-7B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2006-7B,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, +90.1-2019,ASHRAE 169-2006-7B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2006-7B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, +90.1-2019,ASHRAE 169-2006-8A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2006-8A,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, +90.1-2019,ASHRAE 169-2006-8A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2006-8A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, +90.1-2019,ASHRAE 169-2006-8B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2006-8B,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, +90.1-2019,ASHRAE 169-2006-8B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2006-8B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, +90.1-2019,ASHRAE 169-2013-1A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-1A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-1A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-1A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-1B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-1B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-1B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-1B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-2A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-2A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-2A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-2A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-2B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-2B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-2B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-2B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-3A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-3A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-3A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5, +90.1-2019,ASHRAE 169-2013-3A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-3A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-3A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5, +90.1-2019,ASHRAE 169-2013-3B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-3B,TRUE,FALSE,,,,,,,,,,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-3B,TRUE,FALSE,,,,,,,,,,Heating,0.5, +90.1-2019,ASHRAE 169-2013-3B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-3B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-3B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5, +90.1-2019,ASHRAE 169-2013-3C,TRUE,TRUE,,,,,,,,,,,, +90.1-2019,ASHRAE 169-2013-3C,TRUE,FALSE,,,,,,,,,,Heating,0.5, +90.1-2019,ASHRAE 169-2013-3C,FALSE,TRUE,,,,,,,,,,,, +90.1-2019,ASHRAE 169-2013-3C,FALSE,FALSE,,,,,,,,,,Heating,0.5, +90.1-2019,ASHRAE 169-2013-4A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2013-4A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-4A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5, +90.1-2019,ASHRAE 169-2013-4A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2013-4A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-4A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, +90.1-2019,ASHRAE 169-2013-4B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2013-4B,TRUE,FALSE,,,,,,,,,,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-4B,TRUE,FALSE,,,,,,,,,,Heating,0.5, +90.1-2019,ASHRAE 169-2013-4B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2013-4B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-4B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5, +90.1-2019,ASHRAE 169-2013-4C,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2013-4C,TRUE,FALSE,,,,,,,,,,Heating,0.5, +90.1-2019,ASHRAE 169-2013-4C,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2013-4C,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5, +90.1-2019,ASHRAE 169-2013-5A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2013-5A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-5A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5, +90.1-2019,ASHRAE 169-2013-5A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2013-5A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-5A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, +90.1-2019,ASHRAE 169-2013-5B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2013-5B,TRUE,FALSE,,,,,,,,,,Heating,0.5, +90.1-2019,ASHRAE 169-2013-5B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2013-5B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5, +90.1-2019,ASHRAE 169-2013-5C,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2013-5C,TRUE,FALSE,,,,,,26000,12000,5000,4000,Heating,0.5, +90.1-2019,ASHRAE 169-2013-5C,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2013-5C,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5, +90.1-2019,ASHRAE 169-2013-6A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2013-6A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-6A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5, +90.1-2019,ASHRAE 169-2013-6A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2013-6A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-6A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, +90.1-2019,ASHRAE 169-2013-6B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2013-6B,TRUE,FALSE,,28000,26500,11000,5500,4500,3500,2500,1500,Heating,0.5, +90.1-2019,ASHRAE 169-2013-6B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2013-6B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, +90.1-2019,ASHRAE 169-2013-7A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2013-7A,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, +90.1-2019,ASHRAE 169-2013-7A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2013-7A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, +90.1-2019,ASHRAE 169-2013-7B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2013-7B,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, +90.1-2019,ASHRAE 169-2013-7B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2013-7B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, +90.1-2019,ASHRAE 169-2013-8A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2013-8A,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, +90.1-2019,ASHRAE 169-2013-8A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2013-8A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, +90.1-2019,ASHRAE 169-2013-8B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2013-8B,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, +90.1-2019,ASHRAE 169-2013-8B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, +90.1-2019,ASHRAE 169-2013-8B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, +90.1-2010,ASHRAE 169-2006-0A,,,,,,5500,4500,3500,2000,1000,0,,, +90.1-2010,ASHRAE 169-2006-0B,,,,,,,,26000,12000,5000,4000,,, +90.1-2010,ASHRAE 169-2013-0A,,,,,,5500,4500,3500,2000,1000,0,,, +90.1-2010,ASHRAE 169-2013-0B,,,,,,,,26000,12000,5000,4000,,, +90.1-2013,ASHRAE 169-2006-0A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,,, +90.1-2013,ASHRAE 169-2006-0A,FALSE,,,2500,2000,1000,500,0,0,0,0,,, +90.1-2013,ASHRAE 169-2006-0B,TRUE,,,,,,,26000,12000,5000,4000,,, +90.1-2013,ASHRAE 169-2006-0B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,,, +90.1-2013,ASHRAE 169-2013-0A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,,, +90.1-2013,ASHRAE 169-2013-0A,FALSE,,,2500,2000,1000,500,0,0,0,0,,, +90.1-2013,ASHRAE 169-2013-0B,TRUE,,,,,,,26000,12000,5000,4000,,, +90.1-2013,ASHRAE 169-2013-0B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,,, +90.1-2016,ASHRAE 169-2006-0A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, +90.1-2016,ASHRAE 169-2006-0A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, +90.1-2016,ASHRAE 169-2006-0B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5, +90.1-2016,ASHRAE 169-2006-0B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, +90.1-2016,ASHRAE 169-2013-0A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, +90.1-2016,ASHRAE 169-2013-0A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, +90.1-2016,ASHRAE 169-2013-0B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5, +90.1-2016,ASHRAE 169-2013-0B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-0A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-0A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-0A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-0A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-0B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-0B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-0B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2006-0B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-0A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-0A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-0A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-0A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-0B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-0B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-0B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, +90.1-2019,ASHRAE 169-2013-0B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, diff --git a/data/openstudio_standards_data/database_files/system_requirement_energy_recovery_90_1.json b/data/openstudio_standards_data/database_files/system_requirement_energy_recovery_90_1.json new file mode 100644 index 0000000000..95616854c4 --- /dev/null +++ b/data/openstudio_standards_data/database_files/system_requirement_energy_recovery_90_1.json @@ -0,0 +1,7346 @@ +[ + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-1A", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-1B", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-2A", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-2B", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-3A", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-3B", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 5000, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-3C", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 5000, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-4A", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-4B", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 5000, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-4C", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 5000, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-5A", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-5B", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 5000, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-5C", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-6A", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-6B", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": 11000, + "percent_oa_40_to_50": 5500, + "percent_oa_50_to_60": 4500, + "percent_oa_60_to_70": 3500, + "percent_oa_70_to_80": 2500, + "percent_oa_greater_than_80": 1500, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-7A", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-7B", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-8A", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-8B", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-1A", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-1B", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-2A", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-2B", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-3A", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-3B", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 5000, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-3C", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 5000, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-4A", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-4B", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 5000, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-4C", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 5000, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-5A", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-5B", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 5000, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-5C", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-6A", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-6B", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": 11000, + "percent_oa_40_to_50": 5500, + "percent_oa_50_to_60": 4500, + "percent_oa_60_to_70": 3500, + "percent_oa_70_to_80": 2500, + "percent_oa_greater_than_80": 1500, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-7A", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-7B", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-8A", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-8B", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-1A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-1A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-1B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-1B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-2A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-2A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-2B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-2B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-3A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-3A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-3B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-3B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-3C", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-3C", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-4A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-4A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-4B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-4B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-4C", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-4C", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-5A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-5A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-5B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-5B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-5C", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-5C", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-6A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-6A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-6B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 28000, + "percent_oa_20_to_30": 26500, + "percent_oa_30_to_40": 11000, + "percent_oa_40_to_50": 5500, + "percent_oa_50_to_60": 4500, + "percent_oa_60_to_70": 3500, + "percent_oa_70_to_80": 2500, + "percent_oa_greater_than_80": 1500, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-6B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-7A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 4500, + "percent_oa_20_to_30": 4000, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-7A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-7B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 4500, + "percent_oa_20_to_30": 4000, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-7B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-8A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 4500, + "percent_oa_20_to_30": 4000, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-8A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-8B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 4500, + "percent_oa_20_to_30": 4000, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-8B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-1A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-1A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-1B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-1B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-2A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-2A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-2B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-2B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-3A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-3A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-3B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-3B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-3C", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-3C", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-4A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-4A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-4B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-4B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-4C", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-4C", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-5A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-5A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-5B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-5B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-5C", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-5C", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-6A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-6A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-6B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 28000, + "percent_oa_20_to_30": 26500, + "percent_oa_30_to_40": 11000, + "percent_oa_40_to_50": 5500, + "percent_oa_50_to_60": 4500, + "percent_oa_60_to_70": 3500, + "percent_oa_70_to_80": 2500, + "percent_oa_greater_than_80": 1500, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-6B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-7A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 4500, + "percent_oa_20_to_30": 4000, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-7A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-7B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 4500, + "percent_oa_20_to_30": 4000, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-7B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-8A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 4500, + "percent_oa_20_to_30": 4000, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-8A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-8B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 4500, + "percent_oa_20_to_30": 4000, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-8B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-1A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-1A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-1B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-1B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-2A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-2A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-2B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-2B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-3A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-3A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-3B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-3B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-3C", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-3C", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-4A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-4A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-4B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-4B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-4B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-4B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-4C", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-4C", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-5A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-5A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-5B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-5B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-5C", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-5C", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-6A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-6A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-6B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 28000, + "percent_oa_20_to_30": 26500, + "percent_oa_30_to_40": 11000, + "percent_oa_40_to_50": 5500, + "percent_oa_50_to_60": 4500, + "percent_oa_60_to_70": 3500, + "percent_oa_70_to_80": 2500, + "percent_oa_greater_than_80": 1500, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-6B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-7A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 4500, + "percent_oa_20_to_30": 4000, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-7A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-7B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 4500, + "percent_oa_20_to_30": 4000, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-7B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-8A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 4500, + "percent_oa_20_to_30": 4000, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-8A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-8B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 4500, + "percent_oa_20_to_30": 4000, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-8B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-1A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-1A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-1B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-1B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-2A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-2A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-2B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-2B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-3A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-3A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-3B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-3B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-3C", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-3C", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-4A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-4A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-4B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-4B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-4B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-4B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-4C", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-4C", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-5A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-5A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-5B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-5B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-5C", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-5C", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-6A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-6A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-6B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 28000, + "percent_oa_20_to_30": 26500, + "percent_oa_30_to_40": 11000, + "percent_oa_40_to_50": 5500, + "percent_oa_50_to_60": 4500, + "percent_oa_60_to_70": 3500, + "percent_oa_70_to_80": 2500, + "percent_oa_greater_than_80": 1500, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-6B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-7A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 4500, + "percent_oa_20_to_30": 4000, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-7A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-7B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 4500, + "percent_oa_20_to_30": 4000, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-7B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-8A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 4500, + "percent_oa_20_to_30": 4000, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-8A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-8B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 4500, + "percent_oa_20_to_30": 4000, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-8B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-1A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-1A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-1A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-1A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-1B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-1B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-1B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-1B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-2A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-2A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-2A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-2A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-2B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-2B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-2B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-2B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-3A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-3A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-3A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-3A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-3A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-3A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-3B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-3B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-3B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-3B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-3B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-3B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-3C", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-3C", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-3C", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-3C", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-3C", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-3C", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-4A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-4A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-4A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-4A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-4A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-4A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-4B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-4B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-4B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-4B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-4B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-4B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-4C", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-4C", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-4C", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-4C", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-5A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-5A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-5A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-5A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-5A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-5A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-5B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-5B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-5B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-5B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-5C", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-5C", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-5C", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-5C", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-6A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-6A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-6A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-6A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-6A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-6A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-6B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-6B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 28000, + "percent_oa_20_to_30": 26500, + "percent_oa_30_to_40": 11000, + "percent_oa_40_to_50": 5500, + "percent_oa_50_to_60": 4500, + "percent_oa_60_to_70": 3500, + "percent_oa_70_to_80": 2500, + "percent_oa_greater_than_80": 1500, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-6B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-6B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-7A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-7A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 4500, + "percent_oa_20_to_30": 4000, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-7A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-7A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-7B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-7B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 4500, + "percent_oa_20_to_30": 4000, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-7B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-7B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-8A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-8A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 4500, + "percent_oa_20_to_30": 4000, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-8A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-8A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-8B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-8B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 4500, + "percent_oa_20_to_30": 4000, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-8B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-8B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-1A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-1A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-1A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-1A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-1B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-1B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-1B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-1B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-2A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-2A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-2A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-2A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-2B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-2B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-2B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-2B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-3A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-3A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-3A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-3A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-3A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-3A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-3B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-3B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-3B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-3B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-3B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-3B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-3C", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-3C", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-3C", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-3C", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-4A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-4A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-4A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-4A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-4A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-4A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-4B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-4B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-4B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-4B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-4B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-4B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-4C", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-4C", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-4C", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-4C", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-5A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-5A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-5A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-5A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-5A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-5A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-5B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-5B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": null, + "percent_oa_60_to_70": null, + "percent_oa_70_to_80": null, + "percent_oa_greater_than_80": null, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-5B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-5B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-5C", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-5C", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-5C", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-5C", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-6A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-6A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-6A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-6A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-6A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-6A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-6B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-6B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 28000, + "percent_oa_20_to_30": 26500, + "percent_oa_30_to_40": 11000, + "percent_oa_40_to_50": 5500, + "percent_oa_50_to_60": 4500, + "percent_oa_60_to_70": 3500, + "percent_oa_70_to_80": 2500, + "percent_oa_greater_than_80": 1500, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-6B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-6B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-7A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-7A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 4500, + "percent_oa_20_to_30": 4000, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-7A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-7A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-7B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-7B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 4500, + "percent_oa_20_to_30": 4000, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-7B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-7B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-8A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-8A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 4500, + "percent_oa_20_to_30": 4000, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-8A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-8A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-8B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-8B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 4500, + "percent_oa_20_to_30": 4000, + "percent_oa_30_to_40": 2500, + "percent_oa_40_to_50": 1000, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-8B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.6, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-8B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 200, + "percent_oa_20_to_30": 130, + "percent_oa_30_to_40": 100, + "percent_oa_40_to_50": 80, + "percent_oa_50_to_60": 70, + "percent_oa_60_to_70": 60, + "percent_oa_70_to_80": 50, + "percent_oa_greater_than_80": 40, + "enthalpy_recovery_ratio_design_conditions": "Heating", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-0A", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-0B", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-0A", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2013-0B", + "under_8000_hours": null, + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-0A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-0A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-0B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-0B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-0A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-0A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-0B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-0B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": null, + "enthalpy_recovery_ratio": null, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-0A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-0A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-0B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2006-0B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-0A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-0A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-0B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2016", + "climate_zone": "ASHRAE 169-2013-0B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": null, + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-0A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-0A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-0A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-0A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-0B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-0B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-0B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2006-0B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-0A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-0A", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 26000, + "percent_oa_20_to_30": 16000, + "percent_oa_30_to_40": 5500, + "percent_oa_40_to_50": 4500, + "percent_oa_50_to_60": 3500, + "percent_oa_60_to_70": 2000, + "percent_oa_70_to_80": 1000, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-0A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-0A", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": 2500, + "percent_oa_20_to_30": 2000, + "percent_oa_30_to_40": 1000, + "percent_oa_40_to_50": 500, + "percent_oa_50_to_60": 140, + "percent_oa_60_to_70": 120, + "percent_oa_70_to_80": 100, + "percent_oa_greater_than_80": 80, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-0B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-0B", + "under_8000_hours": "TRUE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": null, + "percent_oa_30_to_40": null, + "percent_oa_40_to_50": null, + "percent_oa_50_to_60": 26000, + "percent_oa_60_to_70": 12000, + "percent_oa_70_to_80": 5000, + "percent_oa_greater_than_80": 4000, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-0B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "TRUE", + "percent_oa_0_to_10": 0, + "percent_oa_10_to_20": 0, + "percent_oa_20_to_30": 0, + "percent_oa_30_to_40": 0, + "percent_oa_40_to_50": 0, + "percent_oa_50_to_60": 0, + "percent_oa_60_to_70": 0, + "percent_oa_70_to_80": 0, + "percent_oa_greater_than_80": 0, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + }, + { + "template": "90.1-2019", + "climate_zone": "ASHRAE 169-2013-0B", + "under_8000_hours": "FALSE", + "nontransient_dwelling": "FALSE", + "percent_oa_0_to_10": null, + "percent_oa_10_to_20": null, + "percent_oa_20_to_30": 19500, + "percent_oa_30_to_40": 9000, + "percent_oa_40_to_50": 5000, + "percent_oa_50_to_60": 4000, + "percent_oa_60_to_70": 3000, + "percent_oa_70_to_80": 1500, + "percent_oa_greater_than_80": 120, + "enthalpy_recovery_ratio_design_conditions": "Cooling", + "enthalpy_recovery_ratio": 0.5, + "annotation": null + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_tables/envelope_requirement.py b/data/openstudio_standards_data/database_tables/envelope_requirement.py index 7efa926b14..82ee41f1a6 100644 --- a/data/openstudio_standards_data/database_tables/envelope_requirement.py +++ b/data/openstudio_standards_data/database_tables/envelope_requirement.py @@ -8,7 +8,7 @@ template: TEXT climate_zone_set: TEXT intended_surface_type: TEXT -standard_construction_type: TEXT +standards_construction_type: TEXT building_category: TEXT construction: TEXT orientation: TEXT @@ -30,7 +30,7 @@ template TEXT NOT NULL, climate_zone_set TEXT NOT NULL, intended_surface_type TEXT NOT NULL, -standard_construction_type TEXT, +standards_construction_type TEXT, building_category TEXT NOT NULL, construction TEXT NOT NULL, orientation TEXT, @@ -53,7 +53,7 @@ template, climate_zone_set, intended_surface_type, -standard_construction_type, +standards_construction_type, building_category, construction, orientation, @@ -75,7 +75,7 @@ "template": "", "climate_zone_set": "", "intended_surface_type": "", - "standard_construction_type": "", + "standards_construction_type": "", "building_category": "", "construction": "", "orientation": "", @@ -112,7 +112,7 @@ def validate_record_datatype(self, record): "template", "climate_zone_set", "intended_surface_type", - "standard_construction_type", + "standards_construction_type", "building_category", "construction", "orientation", @@ -153,7 +153,7 @@ def _preprocess_record(self, record): getattr_either("template", record), getattr_either("climate_zone_set", record), getattr_either("intended_surface_type", record), - getattr_either("standard_construction_type", record), + getattr_either("standards_construction_type", record), getattr_either("building_category", record), getattr_either("construction", record), getattr_either("orientation", record), diff --git a/data/openstudio_standards_data/database_tables/support_constructions.py b/data/openstudio_standards_data/database_tables/support_constructions.py index b5600923b6..d82e3130c6 100644 --- a/data/openstudio_standards_data/database_tables/support_constructions.py +++ b/data/openstudio_standards_data/database_tables/support_constructions.py @@ -7,7 +7,7 @@ Must provide a dict that contains following key value pairs: name: TEXT intended_surface_type: TEXT -standard_construction_type: TEXT +standards_construction_type: TEXT insulation_layer: TEXT skylight_framing: TEXT material_1: TEXT @@ -22,7 +22,7 @@ CREATE TABLE IF NOT EXISTS {TABLE_NAME} (name TEXT UNIQUE NOT NULL PRIMARY KEY, intended_surface_type TEXT, -standard_construction_type TEXT, +standards_construction_type TEXT, insulation_layer TEXT, skylight_framing TEXT, material_1 TEXT, @@ -44,7 +44,7 @@ INSERT INTO {TABLE_NAME} (name, intended_surface_type, -standard_construction_type, +standards_construction_type, insulation_layer, skylight_framing, material_1, @@ -60,7 +60,7 @@ RECORD_TEMPLATE = { "name": "", "intended_surface_type": "", - "standard_construction_type": "", + "standards_construction_type": "", "insulation_layer": "", "skylight_framing": "", "material_1": "", @@ -91,7 +91,7 @@ def validate_record_datatype(self, record): str_expected = [ "name", "intended_surface_type", - "standard_construction_type", + "standards_construction_type", "insulation_layer", "skylight_framing", "material_1", @@ -118,7 +118,7 @@ def _preprocess_record(self, record): return ( getattr_either("name", record), getattr_either("intended_surface_type", record), - getattr_either("standard_construction_type", record), + getattr_either("standards_construction_type", record), getattr_either("insulation_layer", record), getattr_either("skylight_framing", record), getattr_either("material_1", record), diff --git a/data/openstudio_standards_data/initial_data/envelope_requirement.csv b/data/openstudio_standards_data/initial_data/envelope_requirement.csv deleted file mode 100644 index 19467ee5b2..0000000000 --- a/data/openstudio_standards_data/initial_data/envelope_requirement.csv +++ /dev/null @@ -1,4534 +0,0 @@ -template,climate_zone_set,intended_surface_type,standards_construction_type,building_category,construction,orientation,minimum_percent_of_surface,maximum_percent_of_surface,assembly_maximum_u_value,u_value_includes_interior_film_coefficient,u_value_includes_exterior_film_coefficient,asssembly_maximum_f_factor,assembly_maximum_c_factor,assembly_maximum_solar_heat_gain_coefficient,assembly_minimum_vt_shgc,annotation -90.1-2004,ClimateZone 1,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 1,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,1.282,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.614,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,1.28,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2004,ClimateZone 1,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,1.18,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 2,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.167,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2004,ClimateZone 2,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.184,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 2,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 2,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 2,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 2,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 2,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 2,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 2,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 2,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 2,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 2,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 2,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 2,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.34 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 2,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 2,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 2,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 3A,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 3B,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 3C,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 3,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2004,ClimateZone 3A,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2004,ClimateZone 3B,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2004,ClimateZone 3C,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2004,ClimateZone 3,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2004,ClimateZone 3A,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2004,ClimateZone 3B,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2004,ClimateZone 3C,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2004,ClimateZone 3,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 3A,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 3B,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 3C,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 3A,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.184,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 3A,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 3A,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 3A,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 3A,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 3A,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 3A,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 3A,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 3A,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 3A,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.39 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.36 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.34 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.34,, -90.1-2004,ClimateZone 3A,Skylight,Plastic with Curb,Nonresidential,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.27,, -90.1-2004,ClimateZone 3A,Skylight,Plastic with Curb,Residential,U 1.30 SHGC 0.27 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.27,, -90.1-2004,ClimateZone 3A,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.39 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,Skylight,Without Curb,Residential,U 0.69 SHGC 0.36 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 3A,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3B,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.184,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 3B,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 3B,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 3B,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 3B,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 3B,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 3B,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 3B,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 3B,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 3B,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.39 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3B,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.36 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,Skylight,Plastic with Curb,Nonresidential,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3B,Skylight,Plastic with Curb,Residential,U 1.30 SHGC 0.27 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 3B,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3B,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.39 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,Skylight,Without Curb,Residential,U 0.69 SHGC 0.36 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.65,, -90.1-2004,ClimateZone 3C,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.184,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.61,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.61,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.61,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Residential,U 0.72 SHGC 0.25 Simple Glazing Window,,40.001,100,0.72,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.72 SHGC 0.25 Simple Glazing Window,,40.001,100,0.72,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Residential,U 0.72 SHGC 0.25 Simple Glazing Window,,40.001,100,0.72,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.61,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Residential,U 0.72 SHGC 0.25 Simple Glazing Window,,40.001,100,0.72,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 3C,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 3C,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 3C,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 3C,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 3C,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 3C,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 3C,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 3C,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 3C,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.61 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.27,, -90.1-2004,ClimateZone 3C,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.39 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.27,, -90.1-2004,ClimateZone 3C,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.39 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.65 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.65 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3C,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 3C,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.61 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3C,Skylight,Without Curb,Residential,U 1.36 SHGC 0.39 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 4,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2004,ClimateZone 4,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.134,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 4,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.95,,,, -90.1-2004,ClimateZone 4,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 4,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.84,,,, -90.1-2004,ClimateZone 4,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 4,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 4,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 4,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 4,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 4,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 4,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.36 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 4,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 4,Skylight,Plastic with Curb,Nonresidential,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,Skylight,Plastic with Curb,Residential,U 1.30 SHGC 0.62 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.65,, -90.1-2004,ClimateZone 4,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.27,, -90.1-2004,ClimateZone 4,Skylight,Without Curb,Residential,U 0.58 SHGC 0.36 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,0.27,, -90.1-2004,ClimateZone 4,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 5,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2004,ClimateZone 5,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 5,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.84,,,, -90.1-2004,ClimateZone 5,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 5,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.84,,,, -90.1-2004,ClimateZone 5,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 5,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 5,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 5,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 5,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 5,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 5,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.36 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 5,Skylight,Plastic with Curb,Nonresidential,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 5,Skylight,Plastic with Curb,Residential,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.61,, -90.1-2004,ClimateZone 5,Skylight,Without Curb,Residential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 6,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.0066,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 6,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2004,ClimateZone 6,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 6,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.84,,,, -90.1-2004,ClimateZone 6,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 6,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.78,,,, -90.1-2004,ClimateZone 6,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 6,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 6,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 6,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 6,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2004,ClimateZone 6,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 6,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.45 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.65 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.65,, -90.1-2004,ClimateZone 6,Skylight,Plastic with Curb,Nonresidential,U 0.87 SHGC 0.71 Simple Glazing Skylight,,0,2,0.87,TRUE,TRUE,,,0.65,, -90.1-2004,ClimateZone 6,Skylight,Plastic with Curb,Residential,U 0.74 SHGC 0.65 Simple Glazing Skylight,,0,2,0.74,TRUE,TRUE,,,0.34,, -90.1-2004,ClimateZone 6,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,Skylight,Without Curb,Residential,U 0.58 SHGC 0.61 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,0.61,, -90.1-2004,ClimateZone 6,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 7,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 7,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2004,ClimateZone 7,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 7,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.84,,,, -90.1-2004,ClimateZone 7,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, -90.1-2004,ClimateZone 7,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.78,,,, -90.1-2004,ClimateZone 7,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 7,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 7,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 7,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2004,ClimateZone 7,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2004,ClimateZone 7,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 7,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.68 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 7,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.64 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,Skylight,Plastic with Curb,Nonresidential,U 0.87 SHGC 0.77 Simple Glazing Skylight,,0,2,0.87,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,Skylight,Plastic with Curb,Residential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 7,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 7,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.68 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,Skylight,Without Curb,Residential,U 0.69 SHGC 0.64 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.65,, -90.1-2004,ClimateZone 8,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 8,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.072,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2004,ClimateZone 8,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.055,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, -90.1-2004,ClimateZone 8,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.78,,,, -90.1-2004,ClimateZone 8,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2004,ClimateZone 8,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.78,,,, -90.1-2004,ClimateZone 8,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 8,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.95,,,, -90.1-2004,ClimateZone 8,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 8,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2004,ClimateZone 8,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2004,ClimateZone 8,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 8,Skylight,Glass with Curb,Nonresidential,U 0.98 SHGC 0.62 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.62,, -90.1-2004,ClimateZone 8,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.27 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.27,, -90.1-2004,ClimateZone 8,Skylight,Glass with Curb,Semiheated,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,Skylight,Plastic with Curb,Nonresidential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,Skylight,Plastic with Curb,Residential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 8,Skylight,Plastic with Curb,Semiheated,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 8,Skylight,Without Curb,Nonresidential,U 0.58 SHGC 0.19 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 8,Skylight,Without Curb,Residential,U 0.58 SHGC 0.45 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,Skylight,Without Curb,Semiheated,U 0.81 SHGC 0.65 Simple Glazing Skylight,,0,2,0.81,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 1,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 1,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 1,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 1,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 1,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 1,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 1,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 1,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 1,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 1,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.36 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 1,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 1,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.16 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.16,, -90.1-2004,ClimateZone 1,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.34 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.34,, -90.1-2004,ClimateZone 1,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.27,, -90.1-2004,ClimateZone 1,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.27,, -90.1-2004,ClimateZone 1,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 1,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.065,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.063,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.65,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,1.28,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2007,ClimateZone 1,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 2,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.167,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2007,ClimateZone 2,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.184,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2007,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.7 SHGC 0.25 Simple Glazing Window,,,,0.7,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.7 SHGC 0.25 Simple Glazing Window,,,,0.7,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 2,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2007,ClimateZone 2,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 2,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2007,ClimateZone 2,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 2,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2007,ClimateZone 2,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 2,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 2,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 2,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 2,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.49,, -90.1-2007,ClimateZone 2,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.49 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.49,, -90.1-2007,ClimateZone 2,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.39,, -90.1-2007,ClimateZone 2,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.49,, -90.1-2007,ClimateZone 2,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.46,, -90.1-2007,ClimateZone 2,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.36,, -90.1-2007,ClimateZone 3,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 3,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2007,ClimateZone 3,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.184,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2007,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 3,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 3,ExteriorWindow,Metal framing (all other),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.9 SHGC 0.25 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 3,GlassDoor,Metal framing (entrance door),Residential,U 0.9 SHGC 0.25 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 3,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 3,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2007,ClimateZone 3,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 3,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.09,,,, -90.1-2007,ClimateZone 3,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 3,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2007,ClimateZone 3,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 3,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 3,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 3,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 3,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.39 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.36 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.71 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.71,, -90.1-2007,ClimateZone 3,Skylight,Plastic with Curb,Nonresidential,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.65,, -90.1-2007,ClimateZone 3,Skylight,Plastic with Curb,Residential,U 1.30 SHGC 0.27 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.55,, -90.1-2007,ClimateZone 3,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.39 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,Skylight,Without Curb,Residential,U 0.69 SHGC 0.36 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.49,, -90.1-2007,ClimateZone 3,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.49,, -90.1-2007,ClimateZone 4,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 4,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2007,ClimateZone 4,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.134,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2007,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.4 SHGC 0.4 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.4 SHGC 0.4 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.85 SHGC 0.4 Simple Glazing Window,,,,0.85,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.85 SHGC 0.4 Simple Glazing Window,,,,0.85,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 4,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2007,ClimateZone 4,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, -90.1-2007,ClimateZone 4,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2007,ClimateZone 4,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 4,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2007,ClimateZone 4,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 4,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 4,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2007,ClimateZone 4,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 4,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.39,, -90.1-2007,ClimateZone 4,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.36 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,Skylight,Plastic with Curb,Nonresidential,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.68,, -90.1-2007,ClimateZone 4,Skylight,Plastic with Curb,Residential,U 1.30 SHGC 0.62 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.64,, -90.1-2007,ClimateZone 4,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.64,, -90.1-2007,ClimateZone 4,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,Skylight,Without Curb,Residential,U 0.58 SHGC 0.36 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.77,, -90.1-2007,ClimateZone 5,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 5,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.119,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2007,ClimateZone 5,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2007,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 5,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2007,ClimateZone 5,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, -90.1-2007,ClimateZone 5,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2007,ClimateZone 5,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 5,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2007,ClimateZone 5,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 5,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2007,ClimateZone 5,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2007,ClimateZone 5,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 5,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.77,, -90.1-2007,ClimateZone 5,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.77,, -90.1-2007,ClimateZone 5,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,Skylight,Plastic with Curb,Nonresidential,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,Skylight,Plastic with Curb,Residential,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,0.68,, -90.1-2007,ClimateZone 5,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.64,, -90.1-2007,ClimateZone 5,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.64,, -90.1-2007,ClimateZone 5,Skylight,Without Curb,Residential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 6,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2007,ClimateZone 6,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2007,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.6 SHGC 0.45 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 0.9 SHGC 0.45 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, -90.1-2007,ClimateZone 6,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2007,ClimateZone 6,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2007,ClimateZone 6,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2007,ClimateZone 6,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 6,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2007,ClimateZone 6,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 6,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2007,ClimateZone 6,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2007,ClimateZone 6,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 6,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.45 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,Skylight,Plastic with Curb,Nonresidential,U 0.87 SHGC 0.71 Simple Glazing Skylight,,0,2,0.87,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,Skylight,Plastic with Curb,Residential,U 0.74 SHGC 0.65 Simple Glazing Skylight,,0,2,0.74,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,Skylight,Without Curb,Residential,U 0.58 SHGC 0.45 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 7,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2007,ClimateZone 7,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.042,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2007,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.45,, -90.1-2007,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,, -90.1-2007,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.45,, -90.1-2007,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.6 SHGC 0.45 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.45,, -90.1-2007,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 0.9 SHGC 0.45 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2007,ClimateZone 7,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.843,,,, -90.1-2007,ClimateZone 7,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2007,ClimateZone 7,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2007,ClimateZone 7,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 7,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2007,ClimateZone 7,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 7,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2007,ClimateZone 7,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, -90.1-2007,ClimateZone 7,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 7,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.68 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.64 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,Skylight,Plastic with Curb,Nonresidential,U 0.87 SHGC 0.77 Simple Glazing Skylight,,0,2,0.87,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,Skylight,Plastic with Curb,Residential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.68 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.36,, -90.1-2007,ClimateZone 7,Skylight,Without Curb,Residential,U 0.69 SHGC 0.64 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.19,, -90.1-2007,ClimateZone 7,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.16,, -90.1-2007,ClimateZone 8,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 8,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.072,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2007,ClimateZone 8,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.036,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.052,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.036,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2007,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.45,, -90.1-2007,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,, -90.1-2007,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.45,, -90.1-2007,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.6 SHGC 0.45 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.45,, -90.1-2007,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 0.9 SHGC 0.45 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2007,ClimateZone 8,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2007,ClimateZone 8,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.51,,,, -90.1-2007,ClimateZone 8,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2007,ClimateZone 8,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 8,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2007,ClimateZone 8,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 8,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2007,ClimateZone 8,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.075,,, -90.1-2007,ClimateZone 8,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 8,Skylight,Glass with Curb,Nonresidential,U 0.98 SHGC 0.45 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.45 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,Skylight,Glass with Curb,Semiheated,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.34,, -90.1-2007,ClimateZone 8,Skylight,Plastic with Curb,Nonresidential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,0.27,, -90.1-2007,ClimateZone 8,Skylight,Plastic with Curb,Residential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,0.27,, -90.1-2007,ClimateZone 8,Skylight,Plastic with Curb,Semiheated,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,Skylight,Without Curb,Nonresidential,U 0.58 SHGC 0.45 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,Skylight,Without Curb,Residential,U 0.58 SHGC 0.36 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,0.36,, -90.1-2007,ClimateZone 8,Skylight,Without Curb,Semiheated,U 0.81 SHGC 0.65 Simple Glazing Skylight,,0,2,0.81,TRUE,TRUE,,,0.19,, -90.1-2007,ClimateZone 1,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,1.18,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2007,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 1,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2007,ClimateZone 1,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 1,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2007,ClimateZone 1,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 1,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2007,ClimateZone 1,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 1,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 1,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 1,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 1,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.49 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.49,, -90.1-2007,ClimateZone 1,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.49,, -90.1-2007,ClimateZone 1,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.39 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.39,, -90.1-2007,ClimateZone 1,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.34 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.77,, -90.1-2007,ClimateZone 1,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.77,, -90.1-2007,ClimateZone 1,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.62,, -90.1-2007,ClimateZone 1,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 1,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.065,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.063,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.065,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.167,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2010,ClimateZone 1,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.093,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 2,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2010,ClimateZone 2,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.093,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.093,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2010,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.7 SHGC 0.25 Simple Glazing Window,,,,0.7,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.7 SHGC 0.25 Simple Glazing Window,,,,0.7,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 2,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2010,ClimateZone 2,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2010,ClimateZone 2,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2010,ClimateZone 2,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 2,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 2,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 2,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 2,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 2,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 2,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 2,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.27 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.27,, -90.1-2010,ClimateZone 2,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.27,, -90.1-2010,ClimateZone 2,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.36,, -90.1-2010,ClimateZone 2,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, -90.1-2010,ClimateZone 2,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.19,, -90.1-2010,ClimateZone 2,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 3,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2010,ClimateZone 3,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2010,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 3,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 3,ExteriorWindow,Metal framing (all other),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.9 SHGC 0.25 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 3,GlassDoor,Metal framing (entrance door),Residential,U 0.9 SHGC 0.25 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 3,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,GroundContactFloor,Unheated,Nonresidential,Smallhotel 2010 Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 3,GroundContactFloor,Heated,Nonresidential,Smallhotel 2010 Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2010,ClimateZone 3,GroundContactFloor,Unheated,Residential,Smallhotel 2010 Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 3,GroundContactFloor,Heated,Residential,Smallhotel 2010 Slab Floor,,,,,TRUE,TRUE,0.09,,,, -90.1-2010,ClimateZone 3,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 3,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2010,ClimateZone 3,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 3,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 3,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 3,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 3,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.39 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.39,, -90.1-2010,ClimateZone 3,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.36 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.36,, -90.1-2010,ClimateZone 3,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.19,, -90.1-2010,ClimateZone 3,Skylight,Plastic with Curb,Nonresidential,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,Skylight,Plastic with Curb,Residential,U 1.30 SHGC 0.27 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.65,, -90.1-2010,ClimateZone 3,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.39 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.27,, -90.1-2010,ClimateZone 3,Skylight,Without Curb,Residential,U 0.69 SHGC 0.36 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.27,, -90.1-2010,ClimateZone 3,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 4,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2010,ClimateZone 4,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2010,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.4 SHGC 0.4 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.4 SHGC 0.4 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.85 SHGC 0.4 Simple Glazing Window,,,,0.85,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.85 SHGC 0.4 Simple Glazing Window,,,,0.85,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 4,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2010,ClimateZone 4,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, -90.1-2010,ClimateZone 4,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2010,ClimateZone 4,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 4,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2010,ClimateZone 4,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 4,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 4,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2010,ClimateZone 4,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 4,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.36 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.39,, -90.1-2010,ClimateZone 4,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.36 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.36,, -90.1-2010,ClimateZone 4,Skylight,Plastic with Curb,Nonresidential,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.19,, -90.1-2010,ClimateZone 4,Skylight,Plastic with Curb,Residential,U 1.30 SHGC 0.62 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.49,, -90.1-2010,ClimateZone 4,Skylight,Without Curb,Residential,U 0.58 SHGC 0.36 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,0.36,, -90.1-2010,ClimateZone 4,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.19,, -90.1-2010,ClimateZone 5,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 5,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.119,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.083,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2010,ClimateZone 5,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.069,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.069,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2010,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 5,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2010,ClimateZone 5,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, -90.1-2010,ClimateZone 5,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2010,ClimateZone 5,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 5,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2010,ClimateZone 5,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 5,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2010,ClimateZone 5,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2010,ClimateZone 5,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 5,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.45 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.65 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.65,, -90.1-2010,ClimateZone 5,Skylight,Plastic with Curb,Nonresidential,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,0.62,, -90.1-2010,ClimateZone 5,Skylight,Plastic with Curb,Residential,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,0.27,, -90.1-2010,ClimateZone 5,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,Skylight,Without Curb,Residential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.49,, -90.1-2010,ClimateZone 5,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.36,, -90.1-2010,ClimateZone 6,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 6,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.072,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2010,ClimateZone 6,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.069,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.069,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2010,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.6 SHGC 0.45 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 0.9 SHGC 0.45 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, -90.1-2010,ClimateZone 6,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2010,ClimateZone 6,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2010,ClimateZone 6,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2010,ClimateZone 6,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 6,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2010,ClimateZone 6,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 6,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2010,ClimateZone 6,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2010,ClimateZone 6,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 6,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.19,, -90.1-2010,ClimateZone 6,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.45 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,Skylight,Plastic with Curb,Nonresidential,U 0.87 SHGC 0.71 Simple Glazing Skylight,,0,2,0.87,TRUE,TRUE,,,0.49,, -90.1-2010,ClimateZone 6,Skylight,Plastic with Curb,Residential,U 0.74 SHGC 0.65 Simple Glazing Skylight,,0,2,0.74,TRUE,TRUE,,,0.49,, -90.1-2010,ClimateZone 6,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.39,, -90.1-2010,ClimateZone 6,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,Skylight,Without Curb,Residential,U 0.58 SHGC 0.45 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.77,, -90.1-2010,ClimateZone 7,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 7,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.072,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2010,ClimateZone 7,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.042,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2010,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.45,, -90.1-2010,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,, -90.1-2010,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.45,, -90.1-2010,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.6 SHGC 0.45 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.45,, -90.1-2010,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 0.9 SHGC 0.45 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2010,ClimateZone 7,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.843,,,, -90.1-2010,ClimateZone 7,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2010,ClimateZone 7,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2010,ClimateZone 7,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 7,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2010,ClimateZone 7,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 7,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2010,ClimateZone 7,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, -90.1-2010,ClimateZone 7,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 7,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.68 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.77,, -90.1-2010,ClimateZone 7,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.64 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.62,, -90.1-2010,ClimateZone 7,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,Skylight,Plastic with Curb,Nonresidential,U 0.87 SHGC 0.77 Simple Glazing Skylight,,0,2,0.87,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,Skylight,Plastic with Curb,Residential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,0.49,, -90.1-2010,ClimateZone 7,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.49,, -90.1-2010,ClimateZone 7,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.68 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.39,, -90.1-2010,ClimateZone 7,Skylight,Without Curb,Residential,U 0.69 SHGC 0.64 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 8,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.035,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.035,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2010,ClimateZone 8,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.036,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.052,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.036,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2010,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.45,, -90.1-2010,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,, -90.1-2010,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.45,, -90.1-2010,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.6 SHGC 0.45 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.45,, -90.1-2010,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 0.9 SHGC 0.45 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2010,ClimateZone 8,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2010,ClimateZone 8,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.51,,,, -90.1-2010,ClimateZone 8,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2010,ClimateZone 8,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 8,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2010,ClimateZone 8,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 8,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2010,ClimateZone 8,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.075,,, -90.1-2010,ClimateZone 8,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 8,Skylight,Glass with Curb,Nonresidential,U 0.98 SHGC 0.49 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.49,, -90.1-2010,ClimateZone 8,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.46 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.46,, -90.1-2010,ClimateZone 8,Skylight,Glass with Curb,Semiheated,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.36,, -90.1-2010,ClimateZone 8,Skylight,Plastic with Curb,Nonresidential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,Skylight,Plastic with Curb,Residential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,Skylight,Plastic with Curb,Semiheated,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,0.71,, -90.1-2010,ClimateZone 8,Skylight,Without Curb,Nonresidential,U 0.58 SHGC 0.65 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,0.65,, -90.1-2010,ClimateZone 8,Skylight,Without Curb,Residential,U 0.58 SHGC 0.55 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,0.55,, -90.1-2010,ClimateZone 8,Skylight,Without Curb,Semiheated,U 0.81 SHGC 0.65 Simple Glazing Skylight,,0,2,0.81,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.093,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2010,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 1,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 1,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2010,ClimateZone 1,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 1,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2010,ClimateZone 1,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 1,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2010,ClimateZone 1,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 1,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 1,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 1,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 1,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.19,, -90.1-2010,ClimateZone 1,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.34 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.36,, -90.1-2010,ClimateZone 1,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, -90.1-2010,ClimateZone 1,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, -90.1-2010,ClimateZone 1,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.39,, -90.1-2013,ClimateZone 1,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 1,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.1156,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2013,ClimateZone 1,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 2,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.096,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2013,ClimateZone 2,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2013,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.4 SHGC 0.25 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.83 SHGC 0.25 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 0.4 SHGC 0.25 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 0.77 SHGC 0.25 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.93 SHGC 0.45 Simple Glazing Window,,,,0.93,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 0.83 SHGC 0.45 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 2,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2013,ClimateZone 2,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 2,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2013,ClimateZone 2,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 2,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2013,ClimateZone 2,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 2,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2013,ClimateZone 2,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2013,ClimateZone 2,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2013,ClimateZone 2,Skylight,Glass with Curb,Nonresidential,U 0.65 SHGC 0.45 Simple Glazing Skylight,,0,2,0.65,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,Skylight,Glass with Curb,Residential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,0,2,0.65,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,Skylight,Glass with Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,0.77,, -90.1-2013,ClimateZone 2,Skylight,Plastic with Curb,Nonresidential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,0,2,0.65,TRUE,TRUE,,,0.77,, -90.1-2013,ClimateZone 2,Skylight,Plastic with Curb,Residential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,0,2,0.65,TRUE,TRUE,,,0.77,, -90.1-2013,ClimateZone 2,Skylight,Plastic with Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,Skylight,Without Curb,Nonresidential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,0,2,0.65,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,Skylight,Without Curb,Residential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,0,2,0.65,TRUE,TRUE,,,0.68,, -90.1-2013,ClimateZone 2,Skylight,Without Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,0.64,, -90.1-2013,ClimateZone 3,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 3,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.119,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.096,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2013,ClimateZone 3,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.077,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.072,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2013,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.25 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 3,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.25 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.25 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 3,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.25 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.87 SHGC 0.45 Simple Glazing Window,,,,0.87,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 3,GlassDoor,Metal framing (entrance door),Residential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 3,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 3,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2013,ClimateZone 3,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, -90.1-2013,ClimateZone 3,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2013,ClimateZone 3,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 3,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2013,ClimateZone 3,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 3,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2013,ClimateZone 3,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2013,ClimateZone 3,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2013,ClimateZone 3,Skylight,Glass with Curb,Nonresidential,U 0.55 SHGC 0.64 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,0.64,, -90.1-2013,ClimateZone 3,Skylight,Glass with Curb,Residential,U 0.55 SHGC 0.45 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,Skylight,Glass with Curb,Semiheated,U 1.70 SHGC 0.36 Simple Glazing Skylight,,0,2,1.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,Skylight,Plastic with Curb,Nonresidential,U 0.55 SHGC 0.45 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,Skylight,Plastic with Curb,Residential,U 0.55 SHGC 0.45 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,Skylight,Plastic with Curb,Semiheated,U 1.70 SHGC 0.36 Simple Glazing Skylight,,0,2,1.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,Skylight,Without Curb,Nonresidential,U 0.55 SHGC 0.45 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,Skylight,Without Curb,Residential,U 0.55 SHGC 0.45 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,Skylight,Without Curb,Semiheated,U 1.70 SHGC 0.36 Simple Glazing Skylight,,0,2,1.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 4,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.082,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2013,ClimateZone 4,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.06,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2013,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.42 SHGC 0.4 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.42 SHGC 0.4 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.4 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.51 SHGC 0.45 Simple Glazing Window,,,,0.51,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.73 SHGC 0.45 Simple Glazing Window,,,,0.73,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.4 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 0.81 SHGC 0.45 Simple Glazing Window,,,,0.81,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2013,ClimateZone 4,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.843,,,, -90.1-2013,ClimateZone 4,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2013,ClimateZone 4,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2013,ClimateZone 4,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 4,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2013,ClimateZone 4,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 4,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2013,ClimateZone 4,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, -90.1-2013,ClimateZone 4,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2013,ClimateZone 4,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,Skylight,Glass with Curb,Semiheated,U 1.15 SHGC 0.77 Simple Glazing Skylight,,0,2,1.15,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,Skylight,Plastic with Curb,Semiheated,U 1.15 SHGC 0.77 Simple Glazing Skylight,,0,2,1.15,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,Skylight,Without Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,Skylight,Without Curb,Semiheated,U 1.15 SHGC 0.77 Simple Glazing Skylight,,0,2,1.15,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 5,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.082,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2013,ClimateZone 5,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.055,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.055,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2013,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.32 SHGC 0.4 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.42 SHGC 0.4 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.32 SHGC 0.4 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.42 SHGC 0.4 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.4 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.62 SHGC 0.45 Simple Glazing Window,,,,0.62,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.4 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 0.7 SHGC 0.45 Simple Glazing Window,,,,0.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2013,ClimateZone 5,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2013,ClimateZone 5,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.51,,,, -90.1-2013,ClimateZone 5,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2013,ClimateZone 5,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 5,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2013,ClimateZone 5,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 5,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2013,ClimateZone 5,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, -90.1-2013,ClimateZone 5,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2013,ClimateZone 5,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.36 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.36,, -90.1-2013,ClimateZone 5,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.19 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.19,, -90.1-2013,ClimateZone 5,Skylight,Glass with Curb,Semiheated,U 0.98 SHGC 0.45 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.34 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.34,, -90.1-2013,ClimateZone 5,Skylight,Plastic with Curb,Semiheated,U 0.98 SHGC 0.27 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.27,, -90.1-2013,ClimateZone 5,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,Skylight,Without Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,Skylight,Without Curb,Semiheated,U 0.98 SHGC 0.36 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.36,, -90.1-2013,ClimateZone 6,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 6,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.031,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.06,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2013,ClimateZone 6,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2013,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.32 SHGC 0.4 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.42 SHGC 0.4 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.4 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.32 SHGC 0.4 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.42 SHGC 0.4 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.4 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.51 SHGC 0.45 Simple Glazing Window,,,,0.51,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 0.59 SHGC 0.45 Simple Glazing Window,,,,0.59,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.51,,,, -90.1-2013,ClimateZone 6,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2013,ClimateZone 6,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.434,,,, -90.1-2013,ClimateZone 6,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.671,,,, -90.1-2013,ClimateZone 6,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 6,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2013,ClimateZone 6,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 6,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, -90.1-2013,ClimateZone 6,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2013,ClimateZone 6,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2013,ClimateZone 6,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.19 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.19,, -90.1-2013,ClimateZone 6,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,Skylight,Glass with Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.36 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.36,, -90.1-2013,ClimateZone 6,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.19 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.19,, -90.1-2013,ClimateZone 6,Skylight,Plastic with Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,0.19,, -90.1-2013,ClimateZone 6,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,Skylight,Without Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,Skylight,Without Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,0.39,, -90.1-2013,ClimateZone 7,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.042,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.042,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.27,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 7,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.039,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2013,ClimateZone 7,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.044,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.044,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.042,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.072,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2013,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.51,,,, -90.1-2013,ClimateZone 7,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.671,,,, -90.1-2013,ClimateZone 7,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.434,,,, -90.1-2013,ClimateZone 7,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.671,,,, -90.1-2013,ClimateZone 7,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 7,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2013,ClimateZone 7,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 7,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2013,ClimateZone 7,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2013,ClimateZone 7,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2013,ClimateZone 7,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.27 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.27,, -90.1-2013,ClimateZone 7,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.27 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.27,, -90.1-2013,ClimateZone 7,Skylight,Glass with Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.36 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.36,, -90.1-2013,ClimateZone 7,Skylight,Plastic with Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,0.19,, -90.1-2013,ClimateZone 7,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.19 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.19,, -90.1-2013,ClimateZone 7,Skylight,Without Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,Skylight,Without Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 8,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.026,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.026,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.039,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2013,ClimateZone 8,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.048,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.039,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.032,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.048,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.039,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.032,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.06,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2013,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.434,,,, -90.1-2013,ClimateZone 8,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.671,,,, -90.1-2013,ClimateZone 8,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.424,,,, -90.1-2013,ClimateZone 8,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.373,,,, -90.1-2013,ClimateZone 8,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, -90.1-2013,ClimateZone 8,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2013,ClimateZone 8,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 8,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2013,ClimateZone 8,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2013,ClimateZone 8,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2013,ClimateZone 8,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.39 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.39,, -90.1-2013,ClimateZone 8,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.36 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.36,, -90.1-2013,ClimateZone 8,Skylight,Glass with Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.65 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.65,, -90.1-2013,ClimateZone 8,Skylight,Plastic with Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,0.27,, -90.1-2013,ClimateZone 8,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,Skylight,Without Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,Skylight,Without Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,0.39,, -90.1-2013,ClimateZone 1,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,1151,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2013,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.93 SHGC 0.25 Simple Glazing Window,,,,0.93,TRUE,TRUE,,,0.25,, -90.1-2013,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2013,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,, -90.1-2013,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2013,ClimateZone 1,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 1,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2013,ClimateZone 1,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 1,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2013,ClimateZone 1,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 1,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2013,ClimateZone 1,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 1,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2013,ClimateZone 1,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2013,ClimateZone 1,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2013,ClimateZone 1,Skylight,Glass with Curb,Nonresidential,U 0.75 SHGC 0.45 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,Skylight,Glass with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.49,, -90.1-2013,ClimateZone 1,Skylight,Glass with Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,0.49,, -90.1-2013,ClimateZone 1,Skylight,Plastic with Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.39,, -90.1-2013,ClimateZone 1,Skylight,Plastic with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,Skylight,Plastic with Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,Skylight,Without Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.68,, -90.1-2013,ClimateZone 1,Skylight,Without Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.64,, -90.1-2013,ClimateZone 1,Skylight,Without Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,0.64,, -90.1-2016,ClimateZone 1,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 1,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 1,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 1,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 1,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 1,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.1156,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2016,ClimateZone 1,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 2,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 2,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 2,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 2,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 2,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.096,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2016,ClimateZone 2,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2016,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.37 SHGC 0.25 Simple Glazing Window,,,,0.37,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.54 SHGC 0.25 Simple Glazing Window,,,,0.54,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.83 SHGC 0.25 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 0.37 SHGC 0.25 Simple Glazing Window,,,,0.37,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.54 SHGC 0.25 Simple Glazing Window,,,,0.54,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 0.77 SHGC 0.25 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.93 SHGC 0.45 Simple Glazing Window,,,,0.93,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 0.83 SHGC 0.45 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 2,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2016,ClimateZone 2,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 2,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2016,ClimateZone 2,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 2,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2016,ClimateZone 2,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 2,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2016,ClimateZone 2,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2016,ClimateZone 2,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2016,ClimateZone 2,Skylight,Glass with Curb,Nonresidential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 2,Skylight,Glass with Curb,Residential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 2,Skylight,Glass with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, -90.1-2016,ClimateZone 2,Skylight,Plastic with Curb,Nonresidential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 2,Skylight,Plastic with Curb,Residential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 2,Skylight,Plastic with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, -90.1-2016,ClimateZone 2,Skylight,Without Curb,Nonresidential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 2,Skylight,Without Curb,Residential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 2,Skylight,Without Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, -90.1-2016,ClimateZone 3,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 3,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 3,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 3,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 3,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 3,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 3,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 3,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.119,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.096,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2016,ClimateZone 3,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.077,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.072,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2016,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.33 SHGC 0.25 Simple Glazing Window,,,,0.33,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 3,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.25 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Residential,U 0.33 SHGC 0.25 Simple Glazing Window,,,,0.33,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 3,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.25 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.87 SHGC 0.45 Simple Glazing Window,,,,0.87,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 3,GlassDoor,Metal framing (entrance door),Residential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 3,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 3,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2016,ClimateZone 3,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, -90.1-2016,ClimateZone 3,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2016,ClimateZone 3,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 3,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2016,ClimateZone 3,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 3,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2016,ClimateZone 3,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2016,ClimateZone 3,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2016,ClimateZone 3,Skylight,Glass with Curb,Nonresidential,U 0.55 SHGC 0.35 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 3,Skylight,Glass with Curb,Residential,U 0.55 SHGC 0.35 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 3,Skylight,Glass with Curb,Semiheated,U 1.7 SHGC 0.55 Simple Glazing Skylight,,,,1.7,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,Skylight,Plastic with Curb,Nonresidential,U 0.55 SHGC 0.35 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 3,Skylight,Plastic with Curb,Residential,U 0.55 SHGC 0.35 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 3,Skylight,Plastic with Curb,Semiheated,U 1.7 SHGC 0.55 Simple Glazing Skylight,,,,1.7,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,Skylight,Without Curb,Nonresidential,U 0.55 SHGC 0.35 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 3,Skylight,Without Curb,Residential,U 0.55 SHGC 0.35 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 3,Skylight,Without Curb,Semiheated,U 1.7 SHGC 0.55 Simple Glazing Skylight,,,,1.7,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 4,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 4,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 4,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 4,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 4,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 4,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 4,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.082,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2016,ClimateZone 4,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.06,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2016,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.31 SHGC 0.36 Simple Glazing Window,,,,0.31,TRUE,TRUE,,,0.36,1.1, -90.1-2016,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.38 SHGC 0.36 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.36,1.1, -90.1-2016,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.31 SHGC 0.36 Simple Glazing Window,,,,0.31,TRUE,TRUE,,,0.36,1.1, -90.1-2016,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.38 SHGC 0.36 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.36,1.1, -90.1-2016,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.36 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.36,1.1, -90.1-2016,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.51 SHGC 0.45 Simple Glazing Window,,,,0.51,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.73 SHGC 0.45 Simple Glazing Window,,,,0.73,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.68 SHGC 0.36 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.36,1.1, -90.1-2016,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2016,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2016,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 0.81 SHGC 0.45 Simple Glazing Window,,,,0.81,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2016,ClimateZone 4,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.843,,,, -90.1-2016,ClimateZone 4,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2016,ClimateZone 4,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2016,ClimateZone 4,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 4,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2016,ClimateZone 4,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 4,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2016,ClimateZone 4,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, -90.1-2016,ClimateZone 4,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2016,ClimateZone 4,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 4,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 4,Skylight,Glass with Curb,Semiheated,U 1.15 SHGC 0.55 Simple Glazing Skylight,,,,1.15,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 4,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 4,Skylight,Plastic with Curb,Semiheated,U 1.15 SHGC 0.55 Simple Glazing Skylight,,,,1.15,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 4,Skylight,Without Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 4,Skylight,Without Curb,Semiheated,U 1.15 SHGC 0.55 Simple Glazing Skylight,,,,1.15,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 5,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 5,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 5,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 5,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 5,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 5,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 5,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.082,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2016,ClimateZone 5,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.055,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.055,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2016,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.31 SHGC 0.38 Simple Glazing Window,,,,0.31,TRUE,TRUE,,,0.38,1.1, -90.1-2016,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.38 SHGC 0.38 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.38,1.1, -90.1-2016,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.31 SHGC 0.38 Simple Glazing Window,,,,0.31,TRUE,TRUE,,,0.38,1.1, -90.1-2016,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.38 SHGC 0.38 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.38,1.1, -90.1-2016,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.38 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.38,1.1, -90.1-2016,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.62 SHGC 0.45 Simple Glazing Window,,,,0.62,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.68 SHGC 0.38 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.38,1.1, -90.1-2016,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2016,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2016,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 0.7 SHGC 0.45 Simple Glazing Window,,,,0.7,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2016,ClimateZone 5,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2016,ClimateZone 5,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.51,,,, -90.1-2016,ClimateZone 5,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2016,ClimateZone 5,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 5,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2016,ClimateZone 5,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 5,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2016,ClimateZone 5,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, -90.1-2016,ClimateZone 5,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2016,ClimateZone 5,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 5,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 5,Skylight,Glass with Curb,Semiheated,U 0.98 SHGC 0.55 Simple Glazing Skylight,,,,0.98,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 5,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 5,Skylight,Plastic with Curb,Semiheated,U 0.98 SHGC 0.55 Simple Glazing Skylight,,,,0.98,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 5,Skylight,Without Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 5,Skylight,Without Curb,Semiheated,U 0.98 SHGC 0.55 Simple Glazing Skylight,,,,0.98,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 6,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 6,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 6,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 6,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 6,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 6,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 6,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.031,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.06,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2016,ClimateZone 6,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2016,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.3 SHGC 0.4 Simple Glazing Window,,,,0.3,TRUE,TRUE,,,0.4,1.1, -90.1-2016,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.36 SHGC 0.4 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.4,1.1, -90.1-2016,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.68 SHGC 0.4 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.4,1.1, -90.1-2016,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.3 SHGC 0.4 Simple Glazing Window,,,,0.3,TRUE,TRUE,,,0.4,1.1, -90.1-2016,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.36 SHGC 0.4 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.4,1.1, -90.1-2016,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.4 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.4,1.1, -90.1-2016,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.51 SHGC 0.45 Simple Glazing Window,,,,0.51,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2016,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2016,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 0.59 SHGC 0.45 Simple Glazing Window,,,,0.59,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.51,,,, -90.1-2016,ClimateZone 6,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2016,ClimateZone 6,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.434,,,, -90.1-2016,ClimateZone 6,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.671,,,, -90.1-2016,ClimateZone 6,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 6,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2016,ClimateZone 6,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 6,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, -90.1-2016,ClimateZone 6,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2016,ClimateZone 6,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2016,ClimateZone 6,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 6,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 6,Skylight,Glass with Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 6,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 6,Skylight,Plastic with Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 6,Skylight,Without Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 6,Skylight,Without Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 7,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 7,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 7,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 7,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 7,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 7,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.042,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.042,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.27,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 7,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.039,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2016,ClimateZone 7,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.044,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.044,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.042,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.072,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2016,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.28 SHGC 0.45 Simple Glazing Window,,,,0.28,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.33 SHGC 0.45 Simple Glazing Window,,,,0.33,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.28 SHGC 0.45 Simple Glazing Window,,,,0.28,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.33 SHGC 0.45 Simple Glazing Window,,,,0.33,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.51,,,, -90.1-2016,ClimateZone 7,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.671,,,, -90.1-2016,ClimateZone 7,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.434,,,, -90.1-2016,ClimateZone 7,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.671,,,, -90.1-2016,ClimateZone 7,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 7,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2016,ClimateZone 7,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 7,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2016,ClimateZone 7,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2016,ClimateZone 7,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2016,ClimateZone 7,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.55 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.55 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,Skylight,Glass with Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.55 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.55 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,Skylight,Plastic with Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.55 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,Skylight,Without Curb,Residential,U 0.5 SHGC 0.55 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,Skylight,Without Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 8,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 8,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 8,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 8,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 8,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 8,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 8,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.026,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.026,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.039,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2016,ClimateZone 8,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.048,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.039,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.048,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.039,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.06,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2016,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.25 SHGC 0.45 Simple Glazing Window,,,,0.25,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.29 SHGC 0.45 Simple Glazing Window,,,,0.29,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.25 SHGC 0.45 Simple Glazing Window,,,,0.25,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.29 SHGC 0.45 Simple Glazing Window,,,,0.29,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.434,,,, -90.1-2016,ClimateZone 8,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.671,,,, -90.1-2016,ClimateZone 8,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.424,,,, -90.1-2016,ClimateZone 8,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.373,,,, -90.1-2016,ClimateZone 8,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, -90.1-2016,ClimateZone 8,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2016,ClimateZone 8,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 8,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2016,ClimateZone 8,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2016,ClimateZone 8,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2016,ClimateZone 8,Skylight,Glass with Curb,Nonresidential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,Skylight,Glass with Curb,Residential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,Skylight,Glass with Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,Skylight,Plastic with Curb,Nonresidential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,Skylight,Plastic with Curb,Residential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,Skylight,Plastic with Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,Skylight,Without Curb,Nonresidential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,Skylight,Without Curb,Residential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,Skylight,Without Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,1151,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2016,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.93 SHGC 0.45 Simple Glazing Window,,,,0.93,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.1 SHGC 0.45 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2016,ClimateZone 1,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 1,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2016,ClimateZone 1,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 1,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2016,ClimateZone 1,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 1,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2016,ClimateZone 1,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 1,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2016,ClimateZone 1,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2016,ClimateZone 1,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2016,ClimateZone 1,Skylight,Glass with Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 1,Skylight,Glass with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 1,Skylight,Glass with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, -90.1-2016,ClimateZone 1,Skylight,Plastic with Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 1,Skylight,Plastic with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 1,Skylight,Plastic with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, -90.1-2016,ClimateZone 1,Skylight,Without Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 1,Skylight,Without Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 1,Skylight,Without Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, -90.1-2019,ClimateZone 1,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 1,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 1,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 1,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 1,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 1,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.1156,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2019,ClimateZone 1,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 2,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 2,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 2,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 2,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 2,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.096,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2019,ClimateZone 2,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2019,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1,Fixed -90.1-2019,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1,Fixed -90.1-2019,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.23 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.23,1.1,Entrance door -90.1-2019,ClimateZone 2,ExteriorWindow,Fixed,Nonresidential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1, -90.1-2019,ClimateZone 2,ExteriorWindow,Operable,Nonresidential,U 0.6 SHGC 0.23 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.23,1.1, -90.1-2019,ClimateZone 2,ExteriorWindow,Entrance door,Nonresidential,U 0.77 SHGC 0.23 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.23,1.1, -90.1-2019,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1,Fixed -90.1-2019,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1,Fixed -90.1-2019,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 0.77 SHGC 0.23 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.23,1.1,Entrance door -90.1-2019,ClimateZone 2,ExteriorWindow,Fixed,Residential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1, -90.1-2019,ClimateZone 2,ExteriorWindow,Operable,Residential,U 0.6 SHGC 0.23 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.23,1.1, -90.1-2019,ClimateZone 2,ExteriorWindow,Entrance door,Residential,U 0.77 SHGC 0.23 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.23,1.1, -90.1-2019,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,,Entrance door -90.1-2019,ClimateZone 2,ExteriorWindow,Fixed,Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorWindow,Operable,Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorWindow,Entrance door,Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2019,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2019,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 2,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2019,ClimateZone 2,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 2,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2019,ClimateZone 2,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 2,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2019,ClimateZone 2,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 2,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2019,ClimateZone 2,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2019,ClimateZone 2,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2019,ClimateZone 2,Skylight,Glass with Curb,Nonresidential,U 0.65 SHGC 0.3 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 2,Skylight,Glass with Curb,Residential,U 0.65 SHGC 0.3 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 2,Skylight,Glass with Curb,Semiheated,U 0.9 SHGC 0.55 Simple Glazing Skylight,,,,0.9,TRUE,TRUE,,,0.55,, -90.1-2019,ClimateZone 2,Skylight,Plastic with Curb,Nonresidential,U 0.65 SHGC 0.3 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 2,Skylight,Plastic with Curb,Residential,U 0.65 SHGC 0.3 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 2,Skylight,Plastic with Curb,Semiheated,U 0.9 SHGC 0.55 Simple Glazing Skylight,,,,0.9,TRUE,TRUE,,,0.55,, -90.1-2019,ClimateZone 2,Skylight,Without Curb,Nonresidential,U 0.65 SHGC 0.3 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 2,Skylight,Without Curb,Residential,U 0.65 SHGC 0.3 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 2,Skylight,Without Curb,Semiheated,U 0.9 SHGC 0.55 Simple Glazing Skylight,,,,0.9,TRUE,TRUE,,,0.55,, -90.1-2019,ClimateZone 3,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 3,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 3,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 3,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 3,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 3,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 3,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 3,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.119,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.096,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2019,ClimateZone 3,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.077,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.072,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2019,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.42 SHGC 0.25 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.25,1.1,Fixed -90.1-2019,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.42 SHGC 0.25 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.25,1.1,Fixed -90.1-2019,ClimateZone 3,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.68 SHGC 0.23 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.23,1.1,Entrance door -90.1-2019,ClimateZone 3,ExteriorWindow,Fixed,Nonresidential,U 0.42 SHGC 0.25 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.25,1.1, -90.1-2019,ClimateZone 3,ExteriorWindow,Operable,Nonresidential,U 0.54 SHGC 0.23 Simple Glazing Window,,,,0.54,TRUE,TRUE,,,0.23,1.1, -90.1-2019,ClimateZone 3,ExteriorWindow,Entrance door,Nonresidential,U 0.68 SHGC 0.23 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.23,1.1, -90.1-2019,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Residential,U 0.42 SHGC 0.25 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.25,1.1,Fixed -90.1-2019,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.42 SHGC 0.25 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.25,1.1,Fixed -90.1-2019,ClimateZone 3,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.23 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.23,1.1,Entrance door -90.1-2019,ClimateZone 3,ExteriorWindow,Fixed,Residential,U 0.42 SHGC 0.25 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.25,1.1, -90.1-2019,ClimateZone 3,ExteriorWindow,Operable,Residential,U 0.54 SHGC 0.23 Simple Glazing Window,,,,0.54,TRUE,TRUE,,,0.23,1.1, -90.1-2019,ClimateZone 3,ExteriorWindow,Entrance door,Residential,U 0.68 SHGC 0.23 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.23,1.1, -90.1-2019,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 3,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,,Entrance door -90.1-2019,ClimateZone 3,ExteriorWindow,Fixed,Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorWindow,Operable,Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorWindow,Entrance door,Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,1.1, -90.1-2019,ClimateZone 3,GlassDoor,Metal framing (entrance door),Residential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,1.1, -90.1-2019,ClimateZone 3,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 3,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2019,ClimateZone 3,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, -90.1-2019,ClimateZone 3,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2019,ClimateZone 3,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 3,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2019,ClimateZone 3,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 3,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2019,ClimateZone 3,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2019,ClimateZone 3,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2019,ClimateZone 3,Skylight,Glass with Curb,Nonresidential,U 0.55 SHGC 0.3 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 3,Skylight,Glass with Curb,Residential,U 0.55 SHGC 0.3 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 3,Skylight,Glass with Curb,Semiheated,U 0.9 SHGC 0.55 Simple Glazing Skylight,,,,0.9,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,Skylight,Plastic with Curb,Nonresidential,U 0.55 SHGC 0.3 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 3,Skylight,Plastic with Curb,Residential,U 0.55 SHGC 0.3 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 3,Skylight,Plastic with Curb,Semiheated,U 0.9 SHGC 0.55 Simple Glazing Skylight,,,,0.9,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,Skylight,Without Curb,Nonresidential,U 0.55 SHGC 0.3 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 3,Skylight,Without Curb,Residential,U 0.55 SHGC 0.3 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 3,Skylight,Without Curb,Semiheated,U 0.9 SHGC 0.55 Simple Glazing Skylight,,,,0.9,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 4,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 4,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 4,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 4,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 4,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 4,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 4,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.082,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2019,ClimateZone 4,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.06,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2019,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1,Fixed -90.1-2019,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1,Fixed -90.1-2019,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1,Fixed -90.1-2019,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1,Fixed -90.1-2019,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1,Entrance door -90.1-2019,ClimateZone 4,ExteriorWindow,Fixed,Residential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1, -90.1-2019,ClimateZone 4,ExteriorWindow,Operable,Residential,U 0.45 SHGC 0.33 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.33,1.1, -90.1-2019,ClimateZone 4,ExteriorWindow,Entrance door,Residential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1, -90.1-2019,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,,Entrance door -90.1-2019,ClimateZone 4,ExteriorWindow,Fixed,Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWindow,Operable,Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWindow,Entrance door,Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1,Entrance door -90.1-2019,ClimateZone 4,ExteriorWindow,Fixed,Nonresidential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1, -90.1-2019,ClimateZone 4,ExteriorWindow,Operable,Nonresidential,U 0.45 SHGC 0.33 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.33,1.1, -90.1-2019,ClimateZone 4,ExteriorWindow,Entrance door,Nonresidential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1, -90.1-2019,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2019,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2019,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 0.81 SHGC 0.45 Simple Glazing Window,,,,0.81,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2019,ClimateZone 4,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.843,,,, -90.1-2019,ClimateZone 4,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2019,ClimateZone 4,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2019,ClimateZone 4,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 4,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2019,ClimateZone 4,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 4,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2019,ClimateZone 4,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, -90.1-2019,ClimateZone 4,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2019,ClimateZone 4,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 4,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 4,Skylight,Glass with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 4,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 4,Skylight,Plastic with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 4,Skylight,Without Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 4,Skylight,Without Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 5,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 5,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 5,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 5,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 5,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 5,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 5,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.082,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2019,ClimateZone 5,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.055,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.055,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2019,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.36 SHGC 0.38 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.38,1.1,Fixed -90.1-2019,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.36 SHGC 0.38 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.38,1.1,Fixed -90.1-2019,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.36 SHGC 0.38 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.38,1.1,Fixed -90.1-2019,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.36 SHGC 0.38 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.38,1.1,Fixed -90.1-2019,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1,Entrance door -90.1-2019,ClimateZone 5,ExteriorWindow,Fixed,Residential,U 0.36 SHGC 0.38 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.38,1.1, -90.1-2019,ClimateZone 5,ExteriorWindow,Operable,Residential,U 0.45 SHGC 0.33 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.33,1.1, -90.1-2019,ClimateZone 5,ExteriorWindow,Entrance door,Residential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1, -90.1-2019,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,,Entrance door -90.1-2019,ClimateZone 5,ExteriorWindow,Fixed,Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWindow,Operable,Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWindow,Entrance door,Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1,Entrance door -90.1-2019,ClimateZone 5,ExteriorWindow,Fixed,Nonresidential,U 0.36 SHGC 0.38 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.38,1.1, -90.1-2019,ClimateZone 5,ExteriorWindow,Operable,Nonresidential,U 0.45 SHGC 0.33 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.33,1.1, -90.1-2019,ClimateZone 5,ExteriorWindow,Entrance door,Nonresidential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1, -90.1-2019,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2019,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2019,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 0.7 SHGC 0.45 Simple Glazing Window,,,,0.7,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2019,ClimateZone 5,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2019,ClimateZone 5,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.51,,,, -90.1-2019,ClimateZone 5,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2019,ClimateZone 5,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 5,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2019,ClimateZone 5,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 5,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2019,ClimateZone 5,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, -90.1-2019,ClimateZone 5,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2019,ClimateZone 5,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 5,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 5,Skylight,Glass with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 5,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 5,Skylight,Plastic with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 5,Skylight,Without Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 5,Skylight,Without Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 6,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 6,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 6,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 6,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 6,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 6,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 6,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.031,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.06,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2019,ClimateZone 6,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2019,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.34 SHGC 0.38 Simple Glazing Window,,,,0.34,TRUE,TRUE,,,0.38,1.1,Fixed -90.1-2019,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.34 SHGC 0.38 Simple Glazing Window,,,,0.34,TRUE,TRUE,,,0.38,1.1,Fixed -90.1-2019,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.63 SHGC 0.34 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.34,1.1,Entrance door -90.1-2019,ClimateZone 6,ExteriorWindow,Fixed,Nonresidential,U 0.34 SHGC 0.38 Simple Glazing Window,,,,0.34,TRUE,TRUE,,,0.38,1.1, -90.1-2019,ClimateZone 6,ExteriorWindow,Operable,Nonresidential,U 0.42 SHGC 0.34 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.34,1.1, -90.1-2019,ClimateZone 6,ExteriorWindow,Entrance door,Nonresidential,U 0.63 SHGC 0.34 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.34,1.1, -90.1-2019,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.34 SHGC 0.38 Simple Glazing Window,,,,0.34,TRUE,TRUE,,,0.38,1.1,Fixed -90.1-2019,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.34 SHGC 0.38 Simple Glazing Window,,,,0.34,TRUE,TRUE,,,0.38,1.1,Fixed -90.1-2019,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.63 SHGC 0.34 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.34,1.1,Entrance door -90.1-2019,ClimateZone 6,ExteriorWindow,Fixed,Residential,U 0.34 SHGC 0.38 Simple Glazing Window,,,,0.34,TRUE,TRUE,,,0.38,1.1, -90.1-2019,ClimateZone 6,ExteriorWindow,Operable,Residential,U 0.42 SHGC 0.34 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.34,1.1, -90.1-2019,ClimateZone 6,ExteriorWindow,Entrance door,Residential,U 0.63 SHGC 0.34 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.34,1.1, -90.1-2019,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.39 SHGC 0.45 Simple Glazing Window,,,,0.39,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.39 SHGC 0.45 Simple Glazing Window,,,,0.39,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,,,Entrance door -90.1-2019,ClimateZone 6,ExteriorWindow,Fixed,Semiheated,U 0.39 SHGC 0.45 Simple Glazing Window,,,,0.39,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorWindow,Operable,Semiheated,U 0.48 SHGC 0.45 Simple Glazing Window,,,,0.48,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorWindow,Entrance door,Semiheated,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2019,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2019,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 0.59 SHGC 0.45 Simple Glazing Window,,,,0.59,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.51,,,, -90.1-2019,ClimateZone 6,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2019,ClimateZone 6,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.434,,,, -90.1-2019,ClimateZone 6,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.671,,,, -90.1-2019,ClimateZone 6,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 6,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2019,ClimateZone 6,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 6,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, -90.1-2019,ClimateZone 6,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2019,ClimateZone 6,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2019,ClimateZone 6,Skylight,Glass with Curb,Nonresidential,U 0.47 SHGC 0.4 Simple Glazing Skylight,,,,0.47,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 6,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 6,Skylight,Glass with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,Skylight,Plastic with Curb,Nonresidential,U 0.47 SHGC 0.4 Simple Glazing Skylight,,,,0.47,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 6,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 6,Skylight,Plastic with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,Skylight,Without Curb,Nonresidential,U 0.47 SHGC 0.4 Simple Glazing Skylight,,,,0.47,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 6,Skylight,Without Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 6,Skylight,Without Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 7,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 7,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 7,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 7,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 7,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 7,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.042,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.042,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.27,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 7,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.039,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2019,ClimateZone 7,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.044,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.044,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.042,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.072,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2019,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.29 SHGC 0.4 Simple Glazing Window,,,,0.29,TRUE,TRUE,,,0.4,1.1,Fixed -90.1-2019,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.29 SHGC 0.4 Simple Glazing Window,,,,0.29,TRUE,TRUE,,,0.4,1.1,Fixed -90.1-2019,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1,Entrance door -90.1-2019,ClimateZone 7,ExteriorWindow,Fixed,Nonresidential,U 0.29 SHGC 0.4 Simple Glazing Window,,,,0.29,TRUE,TRUE,,,0.4,1.1, -90.1-2019,ClimateZone 7,ExteriorWindow,Operable,Nonresidential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1, -90.1-2019,ClimateZone 7,ExteriorWindow,Entrance door,Nonresidential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1, -90.1-2019,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.29 SHGC 0.4 Simple Glazing Window,,,,0.29,TRUE,TRUE,,,0.4,1.1,Fixed -90.1-2019,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.29 SHGC 0.4 Simple Glazing Window,,,,0.29,TRUE,TRUE,,,0.4,1.1,Fixed -90.1-2019,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1,Entrance door -90.1-2019,ClimateZone 7,ExteriorWindow,Fixed,Residential,U 0.26 SHGC 0.4 Simple Glazing Window,,,,0.26,TRUE,TRUE,,,0.4,1.1, -90.1-2019,ClimateZone 7,ExteriorWindow,Operable,Residential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1, -90.1-2019,ClimateZone 7,ExteriorWindow,Entrance door,Residential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1, -90.1-2019,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.36 SHGC 0.45 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.36 SHGC 0.45 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 0.63 SHGC 0.45 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,,,Entrance door -90.1-2019,ClimateZone 7,ExteriorWindow,Fixed,Semiheated,U 0.36 SHGC 0.45 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorWindow,Operable,Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorWindow,Entrance door,Semiheated,U 0.63 SHGC 0.45 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, -90.1-2019,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, -90.1-2019,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.51,,,, -90.1-2019,ClimateZone 7,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.671,,,, -90.1-2019,ClimateZone 7,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.434,,,, -90.1-2019,ClimateZone 7,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.671,,,, -90.1-2019,ClimateZone 7,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 7,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2019,ClimateZone 7,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 7,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2019,ClimateZone 7,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2019,ClimateZone 7,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2019,ClimateZone 7,Skylight,Glass with Curb,Nonresidential,U 0.44 SHGC 0.55 Simple Glazing Skylight,,,,0.44,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,Skylight,Glass with Curb,Residential,U 0.44 SHGC 0.55 Simple Glazing Skylight,,,,0.44,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,Skylight,Glass with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,Skylight,Plastic with Curb,Nonresidential,U 0.44 SHGC 0.55 Simple Glazing Skylight,,,,0.44,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,Skylight,Plastic with Curb,Residential,U 0.44 SHGC 0.55 Simple Glazing Skylight,,,,0.44,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,Skylight,Plastic with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,Skylight,Without Curb,Nonresidential,U 0.44 SHGC 0.55 Simple Glazing Skylight,,,,0.44,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,Skylight,Without Curb,Residential,U 0.44 SHGC 0.55 Simple Glazing Skylight,,,,0.44,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,Skylight,Without Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 8,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 8,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 8,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 8,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 8,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 8,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 8,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.026,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.026,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.039,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2019,ClimateZone 8,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.048,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.039,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.048,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.039,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.06,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2019,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.26 SHGC 0.4 Simple Glazing Window,,,,0.26,TRUE,TRUE,,,0.4,1.1,Fixed -90.1-2019,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.26 SHGC 0.4 Simple Glazing Window,,,,0.26,TRUE,TRUE,,,0.4,1.1,Fixed -90.1-2019,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1,Entrance door -90.1-2019,ClimateZone 8,ExteriorWindow,Fixed,Nonresidential,U 0.26 SHGC 0.4 Simple Glazing Window,,,,0.26,TRUE,TRUE,,,0.4,1.1, -90.1-2019,ClimateZone 8,ExteriorWindow,Operable,Nonresidential,U 0.32 SHGC 0.36 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.36,1.1, -90.1-2019,ClimateZone 8,ExteriorWindow,Entrance door,Nonresidential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1, -90.1-2019,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.26 SHGC 0.4 Simple Glazing Window,,,,0.26,TRUE,TRUE,,,0.4,1.1,Fixed -90.1-2019,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.26 SHGC 0.4 Simple Glazing Window,,,,0.26,TRUE,TRUE,,,0.4,1.1,Fixed -90.1-2019,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1,Entrance door -90.1-2019,ClimateZone 8,ExteriorWindow,Fixed,Residential,U 0.26 SHGC 0.4 Simple Glazing Window,,,,0.26,TRUE,TRUE,,,0.4,1.1, -90.1-2019,ClimateZone 8,ExteriorWindow,Operable,Residential,U 0.32 SHGC 0.36 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.36,1.1, -90.1-2019,ClimateZone 8,ExteriorWindow,Entrance door,Residential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1, -90.1-2019,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.36 SHGC 0.45 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.36 SHGC 0.45 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 0.63 SHGC 0.45 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,,,Entrance door -90.1-2019,ClimateZone 8,ExteriorWindow,Fixed,Semiheated,U 0.36 SHGC 0.45 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorWindow,Operable,Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorWindow,Metal framing (entrance door),Semiheated,U 0.63 SHGC 0.45 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, -90.1-2019,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, -90.1-2019,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.434,,,, -90.1-2019,ClimateZone 8,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.671,,,, -90.1-2019,ClimateZone 8,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.424,,,, -90.1-2019,ClimateZone 8,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.373,,,, -90.1-2019,ClimateZone 8,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, -90.1-2019,ClimateZone 8,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2019,ClimateZone 8,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 8,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2019,ClimateZone 8,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2019,ClimateZone 8,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2019,ClimateZone 8,Skylight,Glass with Curb,Nonresidential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,Skylight,Glass with Curb,Residential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,Skylight,Glass with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,Skylight,Plastic with Curb,Nonresidential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,Skylight,Plastic with Curb,Residential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,Skylight,Plastic with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,Skylight,Without Curb,Nonresidential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,Skylight,Without Curb,Residential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,Skylight,Without Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,1151,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2019,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.5 SHGC 0.23 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.23,1.1,Fixed -90.1-2019,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.5 SHGC 0.23 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.23,1.1,Fixed -90.1-2019,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.83 SHGC 0.21 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.21,1.1,Entrance door -90.1-2019,ClimateZone 1,ExteriorWindow,Fixed,Nonresidential,U 0.5 SHGC 0.23 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.23,1.1, -90.1-2019,ClimateZone 1,ExteriorWindow,Operable,Nonresidential,U 0.62 SHGC 0.21 Simple Glazing Window,,,,0.62,TRUE,TRUE,,,0.21,1.1, -90.1-2019,ClimateZone 1,ExteriorWindow,Entrance door,Nonresidential,U 0.83 SHGC 0.21 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.21,1.1, -90.1-2019,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 0.5 SHGC 0.23 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.23,1.1,Fixed -90.1-2019,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.5 SHGC 0.23 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.23,1.1,Fixed -90.1-2019,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 0.83 SHGC 0.21 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.21,1.1,Entrance door -90.1-2019,ClimateZone 1,ExteriorWindow,Fixed,Residential,U 0.5 SHGC 0.23 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.23,1.1, -90.1-2019,ClimateZone 1,ExteriorWindow,Operable,Residential,U 0.62 SHGC 0.21 Simple Glazing Window,,,,0.62,TRUE,TRUE,,,0.21,1.1, -90.1-2019,ClimateZone 1,ExteriorWindow,Entrance door,Residential,U 0.83 SHGC 0.21 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.21,1.1, -90.1-2019,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.1 SHGC 0.45 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,,,Entrance door -90.1-2019,ClimateZone 1,ExteriorWindow,Fixed,Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorWindow,Operable,Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorWindow,Entrance door,Semiheated,U 1.1 SHGC 0.45 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2019,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2019,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2019,ClimateZone 1,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 1,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2019,ClimateZone 1,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 1,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2019,ClimateZone 1,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 1,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2019,ClimateZone 1,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 1,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2019,ClimateZone 1,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2019,ClimateZone 1,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2019,ClimateZone 1,Skylight,Glass with Curb,Nonresidential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 1,Skylight,Glass with Curb,Residential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 1,Skylight,Glass with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, -90.1-2019,ClimateZone 1,Skylight,Plastic with Curb,Nonresidential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 1,Skylight,Plastic with Curb,Residential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 1,Skylight,Plastic with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, -90.1-2019,ClimateZone 1,Skylight,Without Curb,Nonresidential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 1,Skylight,Without Curb,Residential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 1,Skylight,Without Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, -90.1-2016,ClimateZone 0,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 0,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 0,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 0,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 0,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 0,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.115,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2016,ClimateZone 0,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2016,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.32 SHGC 0.22 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.22,1.1, -90.1-2016,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1, -90.1-2016,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.83 SHGC 0.22 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.22,1.1, -90.1-2016,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 0.32 SHGC 0.22 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.22,1.1, -90.1-2016,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1, -90.1-2016,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 0.83 SHGC 0.22 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.22,1.1, -90.1-2016,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.93 SHGC 0.45 Simple Glazing Window,,,,0.93,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.1 SHGC 0.45 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2016,ClimateZone 0,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 0,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2016,ClimateZone 0,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 0,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2016,ClimateZone 0,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 0,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2016,ClimateZone 0,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 0,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2016,ClimateZone 0,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2016,ClimateZone 0,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2016,ClimateZone 0,Skylight,Glass with Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 0,Skylight,Glass with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 0,Skylight,Glass with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, -90.1-2016,ClimateZone 0,Skylight,Plastic with Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 0,Skylight,Plastic with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 0,Skylight,Plastic with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, -90.1-2016,ClimateZone 0,Skylight,Without Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 0,Skylight,Without Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 0,Skylight,Without Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, -90.1-2019,ClimateZone 0,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 0,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 0,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 0,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 0,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 0,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.115,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2019,ClimateZone 0,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2019,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1,Fixed -90.1-2019,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1,Fixed -90.1-2019,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.83 SHGC 0.2 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.2,1.1,Entrance door -90.1-2019,ClimateZone 0,ExteriorWindow,Fixed,Nonresidential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1, -90.1-2019,ClimateZone 0,ExteriorWindow,Operable,Nonresidential,U 0.62 SHGC 0.2 Simple Glazing Window,,,,0.62,TRUE,TRUE,,,0.2,1.1, -90.1-2019,ClimateZone 0,ExteriorWindow,Entrance door,Nonresidential,U 0.83 SHGC 0.2 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.2,1.1, -90.1-2019,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1,Fixed -90.1-2019,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1,Fixed -90.1-2019,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 0.83 SHGC 0.2 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.2,1.1,Entrance door -90.1-2019,ClimateZone 0,ExteriorWindow,Fixed,Residential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1, -90.1-2019,ClimateZone 0,ExteriorWindow,Operable,Residential,U 0.62 SHGC 0.2 Simple Glazing Window,,,,0.62,TRUE,TRUE,,,0.2,1.1, -90.1-2019,ClimateZone 0,ExteriorWindow,Entrance door,Residential,U 0.83 SHGC 0.2 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.2,1.1, -90.1-2019,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.1 SHGC 0.45 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,,,Entrance door -90.1-2019,ClimateZone 0,ExteriorWindow,Fixed,Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorWindow,Operable,Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorWindow,Entrance door,Semiheated,U 1.1 SHGC 0.45 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2019,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2019,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2019,ClimateZone 0,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 0,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2019,ClimateZone 0,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 0,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2019,ClimateZone 0,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 0,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2019,ClimateZone 0,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 0,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2019,ClimateZone 0,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2019,ClimateZone 0,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2019,ClimateZone 0,Skylight,Glass with Curb,Nonresidential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 0,Skylight,Glass with Curb,Residential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 0,Skylight,Glass with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,Skylight,Plastic with Curb,Nonresidential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 0,Skylight,Plastic with Curb,Residential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 0,Skylight,Plastic with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,Skylight,Without Curb,Nonresidential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 0,Skylight,Without Curb,Residential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 0,Skylight,Without Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 0,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,1.282,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.614,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,1.28,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2004,ClimateZone 0,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,1.18,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 0,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 0,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 0,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 0,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 0,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 0,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 0,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 0,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 0,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 0,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.36 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 0,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 0,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.16 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.16,, -90.1-2004,ClimateZone 0,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.34 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.34,, -90.1-2004,ClimateZone 0,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.27,, -90.1-2004,ClimateZone 0,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.27,, -90.1-2004,ClimateZone 0,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 0,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.065,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.063,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.65,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,1.28,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2007,ClimateZone 0,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,1.18,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2007,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 0,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2007,ClimateZone 0,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 0,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2007,ClimateZone 0,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 0,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2007,ClimateZone 0,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 0,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 0,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 0,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 0,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.49 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.49,, -90.1-2007,ClimateZone 0,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.49,, -90.1-2007,ClimateZone 0,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.39 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.39,, -90.1-2007,ClimateZone 0,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.34 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.77,, -90.1-2007,ClimateZone 0,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.77,, -90.1-2007,ClimateZone 0,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.62,, -90.1-2007,ClimateZone 0,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 0,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.065,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.063,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.065,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.167,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2010,ClimateZone 0,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.093,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.093,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2010,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 0,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 0,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2010,ClimateZone 0,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 0,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2010,ClimateZone 0,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 0,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2010,ClimateZone 0,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 0,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 0,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 0,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 0,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.19,, -90.1-2010,ClimateZone 0,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.34 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.36,, -90.1-2010,ClimateZone 0,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, -90.1-2010,ClimateZone 0,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, -90.1-2010,ClimateZone 0,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.39,, -90.1-2013,ClimateZone 0,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 0,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.1156,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2013,ClimateZone 0,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2013,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.93 SHGC 0.25 Simple Glazing Window,,,,0.93,TRUE,TRUE,,,0.25,, -90.1-2013,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2013,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,, -90.1-2013,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2013,ClimateZone 0,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 0,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2013,ClimateZone 0,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 0,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2013,ClimateZone 0,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 0,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2013,ClimateZone 0,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 0,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2013,ClimateZone 0,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2013,ClimateZone 0,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2013,ClimateZone 0,Skylight,Glass with Curb,Nonresidential,U 0.75 SHGC 0.45 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,Skylight,Glass with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.49,, -90.1-2013,ClimateZone 0,Skylight,Glass with Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,0.49,, -90.1-2013,ClimateZone 0,Skylight,Plastic with Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.39,, -90.1-2013,ClimateZone 0,Skylight,Plastic with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,Skylight,Plastic with Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,Skylight,Without Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.68,, -90.1-2013,ClimateZone 0,Skylight,Without Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.64,, -90.1-2013,ClimateZone 0,Skylight,Without Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,0.64,, diff --git a/data/openstudio_standards_data/initial_data/general_building_space_type.json b/data/openstudio_standards_data/initial_data/general_building_space_type.json deleted file mode 100644 index 2b14fa77c2..0000000000 --- a/data/openstudio_standards_data/initial_data/general_building_space_type.json +++ /dev/null @@ -1,898 +0,0 @@ -[ - { - "id": 1, - "space_type": "chapel - visually impaired", - "lighting_subspace_type": "chapel_visually_impaired", - "ventilation_subspace_type": "public_assembly_spaces_religious_workshop", - "plug_load_subspace_type": null - }, - { - "id": 2, - "space_type": "recreation/common living - visually impaired", - "lighting_subspace_type": "recreation_common_living_visually_impaired", - "ventilation_subspace_type": "hotels_motels_resorts_dormitories_multi_purpose_assembly", - "plug_load_subspace_type": null - }, - { - "id": 3, - "space_type": "atrium < 20 ft height", - "lighting_subspace_type": "atrium_low", - "ventilation_subspace_type": "office_buildings_main_entry_lobbies", - "plug_load_subspace_type": "atrium < 20 ft height" - }, - { - "id": 4, - "space_type": "atrium >= 20 ft and <= 40 ft in height", - "lighting_subspace_type": "atrium_medium", - "ventilation_subspace_type": "office_buildings_main_entry_lobbies", - "plug_load_subspace_type": "atrium >= 20 ft and <= 40 ft in height" - }, - { - "id": 5, - "space_type": "atrium > 40 ft height", - "lighting_subspace_type": "atrium_high", - "ventilation_subspace_type": "office_buildings_main_entry_lobbies", - "plug_load_subspace_type": "atrium > 40 ft height" - }, - { - "id": 6, - "space_type": "audience seating - convention center", - "lighting_subspace_type": "audience_seating_convention_center", - "ventilation_subspace_type": "public_assembly_spaces_auditorium_seating_area", - "plug_load_subspace_type": "audience seating - convention center" - }, - { - "id": 7, - "space_type": "audience seating - exercise center", - "lighting_subspace_type": "audience_seating_exercise_center", - "ventilation_subspace_type": "sports_entertainment_spectator_areas", - "plug_load_subspace_type": "audience seating - exercise center" - }, - { - "id": 8, - "space_type": "audience seating - all other", - "lighting_subspace_type": "audience_seating_general", - "ventilation_subspace_type": "public_assembly_spaces_auditorium_seating_area", - "plug_load_subspace_type": "audience seating - all other" - }, - { - "id": 9, - "space_type": "audience seating - auditorium", - "lighting_subspace_type": "audience_seating_auditorium", - "ventilation_subspace_type": "public_assembly_spaces_auditorium_seating_area", - "plug_load_subspace_type": "audience seating - auditorium" - }, - { - "id": 10, - "space_type": "audience seating - gymnasium", - "lighting_subspace_type": "audience_seating_gymnasium", - "ventilation_subspace_type": "sports_entertainment_spectator_areas", - "plug_load_subspace_type": "audience seating - gymnasium" - }, - { - "id": 11, - "space_type": "audience seating - sports arena", - "lighting_subspace_type": "audience_seating_sports_arena", - "ventilation_subspace_type": "sports_entertainment_spectator_areas", - "plug_load_subspace_type": "audience seating - sports arena" - }, - { - "id": 12, - "space_type": "audience seating - motion picture theater", - "lighting_subspace_type": "audience_seating_motion_picture_theater", - "ventilation_subspace_type": "public_assembly_spaces_auditorium_seating_area", - "plug_load_subspace_type": "audience seating - motion picture theater" - }, - { - "id": 13, - "space_type": "audience seating - penitentiary", - "lighting_subspace_type": "audience_seating_penitentiary", - "ventilation_subspace_type": "public_assembly_spaces_auditorium_seating_area", - "plug_load_subspace_type": null - }, - { - "id": 14, - "space_type": "audience seating - performing arts theater", - "lighting_subspace_type": "audience_seating_performing_arts_theater", - "ventilation_subspace_type": "public_assembly_spaces_auditorium_seating_area", - "plug_load_subspace_type": "audience seating - performing arts theater" - }, - { - "id": 15, - "space_type": "audience seating - religious facility", - "lighting_subspace_type": "audience_seating_religious_facility", - "ventilation_subspace_type": "public_assembly_spaces_auditorium_seating_area", - "plug_load_subspace_type": "audience seating - religious facility" - }, - { - "id": 16, - "space_type": "audience seating - transportation facility", - "lighting_subspace_type": "audience_seating_transportation", - "ventilation_subspace_type": "public_assembly_spaces_auditorium_seating_area", - "plug_load_subspace_type": null - }, - { - "id": 17, - "space_type": "automotive", - "lighting_subspace_type": "automotive", - "ventilation_subspace_type": "miscellaneous_spaces_transportation_waiting", - "plug_load_subspace_type": null - }, - { - "id": 18, - "space_type": "banking activity", - "lighting_subspace_type": "banking_activity", - "ventilation_subspace_type": "miscellaneous_spaces_banks_bank_lobbies", - "plug_load_subspace_type": "banking activity" - }, - { - "id": 19, - "space_type": "classroom/lecture/training - all other", - "lighting_subspace_type": "classroom_lecture_training_general", - "ventilation_subspace_type": "educational_facilities_classroom_old", - "plug_load_subspace_type": "classroom/lecture/training - all other" - }, - { - "id": 20, - "space_type": "classroom/lecture/training - penitentiary", - "lighting_subspace_type": "classroom_lecture_training_penitentiary", - "ventilation_subspace_type": "correctional_facilities_dayroom", - "plug_load_subspace_type": "classroom/lecture/training - penitentiary" - }, - { - "id": 21, - "space_type": "classroom - laboratory or shop", - "lighting_subspace_type": "laboratory_classroom", - "ventilation_subspace_type": "educational_facilities_university_college_laboratories", - "plug_load_subspace_type": null - }, - { - "id": 22, - "space_type": "classroom/lecture/training - preschool to 12th", - "lighting_subspace_type": "classroom_lecture_training_general", - "ventilation_subspace_type": "educational_facilities_classroom_young", - "plug_load_subspace_type": "classroom/lecture/training - preschool to 12th" - }, - { - "id": 23, - "space_type": "computer room", - "lighting_subspace_type": "computer_room", - "ventilation_subspace_type": "miscellaneous_spaces_computer", - "plug_load_subspace_type": "computer room" - }, - { - "id": 24, - "space_type": "conference/meeting/multipurpose", - "lighting_subspace_type": "conference_meeting_multipurpose", - "ventilation_subspace_type": "general_conference_meeting", - "plug_load_subspace_type": "conference/meeting/multipurpose" - }, - { - "id": 25, - "space_type": "confinement cells", - "lighting_subspace_type": "confinement_cells", - "ventilation_subspace_type": "correctional_facilities_cell", - "plug_load_subspace_type": "confinement cells" - }, - { - "id": 26, - "space_type": "exhibit - convention center", - "lighting_subspace_type": "exhibit_convention_center", - "ventilation_subspace_type": "public_assembly_spaces_museums_galleries", - "plug_load_subspace_type": "exhibit - convention center" - }, - { - "id": 27, - "space_type": "copy/print", - "lighting_subspace_type": "copy_print", - "ventilation_subspace_type": "office_buildings_telephone_data_entry", - "plug_load_subspace_type": null - }, - { - "id": 28, - "space_type": "corridor for visually impaired", - "lighting_subspace_type": "corridor_visually_impaired", - "ventilation_subspace_type": "general_conference_corridors", - "plug_load_subspace_type": null - }, - { - "id": 29, - "space_type": "corridor - hospital", - "lighting_subspace_type": "corridor_hospital", - "ventilation_subspace_type": "general_conference_corridors", - "plug_load_subspace_type": "corridor - hospital" - }, - { - "id": 30, - "space_type": "corridor - manufacturing facility", - "lighting_subspace_type": "corridor_manufacturing_facility", - "ventilation_subspace_type": "general_conference_corridors", - "plug_load_subspace_type": "corridor - manufacturing facility" - }, - { - "id": 31, - "space_type": "corridor - all other", - "lighting_subspace_type": "corridor_general", - "ventilation_subspace_type": "general_conference_corridors", - "plug_load_subspace_type": "corridor - all other" - }, - { - "id": 32, - "space_type": "courtroom", - "lighting_subspace_type": "courtroom", - "ventilation_subspace_type": "public_assembly_spaces_courtrooms", - "plug_load_subspace_type": "courtroom" - }, - { - "id": 33, - "space_type": "dining - all other", - "lighting_subspace_type": "dining_general", - "ventilation_subspace_type": "food_beverage_service_restaurant_dining_rooms", - "plug_load_subspace_type": "dining - all other" - }, - { - "id": 34, - "space_type": "dining - bar/lounge/leisure", - "lighting_subspace_type": "dining_bar_lounge_leisure", - "ventilation_subspace_type": "food_beverage_service_bars_cocktail_lounges", - "plug_load_subspace_type": "dining - bar/lounge/leisure" - }, - { - "id": 35, - "space_type": "dining - cafeteria/fast food", - "lighting_subspace_type": "dining_cafeteria_fast_food", - "ventilation_subspace_type": "food_beverage_service_cafeteria_fast_food_dining", - "plug_load_subspace_type": "dining - cafeteria/fast food" - }, - { - "id": 36, - "space_type": "dining for visually impaired", - "lighting_subspace_type": "dining_visually_impaired", - "ventilation_subspace_type": "food_beverage_service_restaurant_dining_rooms", - "plug_load_subspace_type": null - }, - { - "id": 37, - "space_type": "dining - family", - "lighting_subspace_type": "dining_family", - "ventilation_subspace_type": "food_beverage_service_restaurant_dining_rooms", - "plug_load_subspace_type": "dining - family" - }, - { - "id": 38, - "space_type": "dining - penitentiary", - "lighting_subspace_type": "dining_penitentiary", - "ventilation_subspace_type": "food_beverage_service_restaurant_dining_rooms", - "plug_load_subspace_type": "dining - penitentiary" - }, - { - "id": 39, - "space_type": "dining - hotel", - "lighting_subspace_type": "dining_hotel", - "ventilation_subspace_type": "food_beverage_service_restaurant_dining_rooms", - "plug_load_subspace_type": null - }, - { - "id": 40, - "space_type": "dining - motel", - "lighting_subspace_type": "dining_motel", - "ventilation_subspace_type": "food_beverage_service_restaurant_dining_rooms", - "plug_load_subspace_type": null - }, - { - "id": 41, - "space_type": "dormitory - living quarters", - "lighting_subspace_type": "dormitory_living_quarters", - "ventilation_subspace_type": "hotels_motels_resorts_dormitories_bedroom_living_room", - "plug_load_subspace_type": "dormitory - living quarters" - }, - { - "id": 42, - "space_type": "electrical/mechanical", - "lighting_subspace_type": "electrical_mechanical", - "ventilation_subspace_type": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", - "plug_load_subspace_type": "electrical/mechanical" - }, - { - "id": 43, - "space_type": "emergency vehicle garage", - "lighting_subspace_type": "emergency_vehicle_garage", - "ventilation_subspace_type": "miscellaneous_spaces_transportation_waiting", - "plug_load_subspace_type": "emergency vehicle garage" - }, - { - "id": 44, - "space_type": "firestation - sleeping quarters", - "lighting_subspace_type": "firestation_sleeping_quarters", - "ventilation_subspace_type": "hotels_motels_resorts_dormitories_barracks_sleeping_areas", - "plug_load_subspace_type": "firestation - sleeping quarters" - }, - { - "id": 45, - "space_type": "kitchen", - "lighting_subspace_type": "kitchen", - "ventilation_subspace_type": "food_beverage_service_kitchen", - "plug_load_subspace_type": "kitchen" - }, - { - "id": 46, - "space_type": "guest room", - "lighting_subspace_type": "guest_room", - "ventilation_subspace_type": "hotels_motels_resorts_dormitories_barracks_sleeping_areas", - "plug_load_subspace_type": "guest room" - }, - { - "id": 47, - "space_type": "gymnasium exercise area", - "lighting_subspace_type": "gymnasium_exercise_area", - "ventilation_subspace_type": "sports_entertainment_gym_stadium", - "plug_load_subspace_type": "gymnasium exercise area" - }, - { - "id": 48, - "space_type": "gymnasium playing area", - "lighting_subspace_type": "gymnasium_playing_area", - "ventilation_subspace_type": "sports_entertainment_gym_stadium", - "plug_load_subspace_type": "gymnasium playing area" - }, - { - "id": 49, - "space_type": "emergency room", - "lighting_subspace_type": "emergency_room", - "ventilation_subspace_type": "outpatient_health_care_facilities_general_examination_room", - "plug_load_subspace_type": "emergency room" - }, - { - "id": 50, - "space_type": "exam/treatment", - "lighting_subspace_type": "exam_treatment", - "ventilation_subspace_type": "outpatient_health_care_facilities_general_examination_room", - "plug_load_subspace_type": "exam/treatment" - }, - { - "id": 51, - "space_type": "imaging", - "lighting_subspace_type": "imaging", - "ventilation_subspace_type": "outpatient_health_care_facilities_class_1_imaging_rooms", - "plug_load_subspace_type": null - }, - { - "id": 52, - "space_type": "medical supply", - "lighting_subspace_type": "medical_supply", - "ventilation_subspace_type": "miscellaneous_spaces_pharmacy", - "plug_load_subspace_type": null - }, - { - "id": 53, - "space_type": "nursery", - "lighting_subspace_type": "nursery", - "ventilation_subspace_type": "outpatient_health_care_facilities_psychiatric_consultation_room", - "plug_load_subspace_type": null - }, - { - "id": 54, - "space_type": "nurses station", - "lighting_subspace_type": "nurses_station", - "ventilation_subspace_type": "outpatient_health_care_facilities_psychiatric_consultation_room", - "plug_load_subspace_type": "nurses station" - }, - { - "id": 55, - "space_type": "operating room", - "lighting_subspace_type": "operating_room", - "ventilation_subspace_type": "outpatient_health_care_facilities_general_examination_room", - "plug_load_subspace_type": "operating room" - }, - { - "id": 56, - "space_type": "patient room", - "lighting_subspace_type": "patient_room", - "ventilation_subspace_type": "outpatient_health_care_facilities_physical_therapy_individual_room", - "plug_load_subspace_type": "patient room" - }, - { - "id": 57, - "space_type": "physical therapy", - "lighting_subspace_type": "physical_therapy", - "ventilation_subspace_type": "outpatient_health_care_facilities_physical_therapy_exercise_area", - "plug_load_subspace_type": "physical therapy" - }, - { - "id": 58, - "space_type": "recovery", - "lighting_subspace_type": "recovery", - "ventilation_subspace_type": "outpatient_health_care_facilities_urgent_care_examination_room", - "plug_load_subspace_type": null - }, - { - "id": 59, - "space_type": "judges chambers", - "lighting_subspace_type": "judges_chambers", - "ventilation_subspace_type": "public_assembly_spaces_legislative_chambers", - "plug_load_subspace_type": "judges chambers" - }, - { - "id": 60, - "space_type": "laboratory", - "lighting_subspace_type": "laboratory_all_other", - "ventilation_subspace_type": "educational_facilities_science_laboratories", - "plug_load_subspace_type": "laboratory" - }, - { - "id": 61, - "space_type": "library - reading", - "lighting_subspace_type": "library_reading", - "ventilation_subspace_type": "public_assembly_spaces_libraries", - "plug_load_subspace_type": "library - reading" - }, - { - "id": 62, - "space_type": "library - stacks", - "lighting_subspace_type": "library_stacks", - "ventilation_subspace_type": "public_assembly_spaces_libraries", - "plug_load_subspace_type": "library - stacks" - }, - { - "id": 63, - "space_type": "library - cataloging", - "lighting_subspace_type": "library_cataloging", - "ventilation_subspace_type": "public_assembly_spaces_libraries", - "plug_load_subspace_type": "library - cataloging" - }, - { - "id": 64, - "space_type": "loading dock", - "lighting_subspace_type": "loading_dock", - "ventilation_subspace_type": "miscellaneous_spaces_sorting_packing_light_assembly", - "plug_load_subspace_type": null - }, - { - "id": 65, - "space_type": "lobby - all other", - "lighting_subspace_type": "lobby_general", - "ventilation_subspace_type": "public_assembly_spaces_lobbies", - "plug_load_subspace_type": "lobby - all other" - }, - { - "id": 66, - "space_type": "lobby - elevator", - "lighting_subspace_type": "lobby_elevator", - "ventilation_subspace_type": "public_assembly_spaces_lobbies", - "plug_load_subspace_type": "lobby - elevator" - }, - { - "id": 67, - "space_type": "lobby for visually impaired", - "lighting_subspace_type": "lobby_visually_impaired", - "ventilation_subspace_type": "public_assembly_spaces_lobbies", - "plug_load_subspace_type": null - }, - { - "id": 68, - "space_type": "lobby - hotel", - "lighting_subspace_type": "lobby_hotel", - "ventilation_subspace_type": "hotels_motels_resorts_dormitories_lobbies_prefunction", - "plug_load_subspace_type": "lobby - hotel" - }, - { - "id": 69, - "space_type": "lobby - motion picture theater", - "lighting_subspace_type": "lobby_motion_picture_theater", - "ventilation_subspace_type": "public_assembly_spaces_lobbies", - "plug_load_subspace_type": "lobby - motion picture theater" - }, - { - "id": 70, - "space_type": "lobby - performing arts theater", - "lighting_subspace_type": "lobby_performing_arts_theater", - "ventilation_subspace_type": "public_assembly_spaces_lobbies", - "plug_load_subspace_type": "lobby - performing arts theater" - }, - { - "id": 71, - "space_type": "locker room", - "lighting_subspace_type": "locker_room", - "ventilation_subspace_type": "general_break_rooms", - "plug_load_subspace_type": "locker room" - }, - { - "id": 72, - "space_type": "lounge/breakroom - all other", - "lighting_subspace_type": "lounge_breakroom_general", - "ventilation_subspace_type": "general_break_rooms", - "plug_load_subspace_type": "lounge/breakroom - all other" - }, - { - "id": 73, - "space_type": "lounge/breakroom - healthcare facility", - "lighting_subspace_type": "lounge_breakroom_healthcare_facility", - "ventilation_subspace_type": "general_break_rooms", - "plug_load_subspace_type": "lounge/breakroom - healthcare facility" - }, - { - "id": 74, - "space_type": "laundry/washing", - "lighting_subspace_type": "laundry_washing", - "ventilation_subspace_type": "hotels_motels_resorts_dormitories_laundry_rooms", - "plug_load_subspace_type": "laundry/washing" - }, - { - "id": 75, - "space_type": "detailed manufacuring", - "lighting_subspace_type": "detailed_manufacuring", - "ventilation_subspace_type": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", - "plug_load_subspace_type": null - }, - { - "id": 76, - "space_type": "manufacturing equipment room", - "lighting_subspace_type": "manufacturing_equipment_room", - "ventilation_subspace_type": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", - "plug_load_subspace_type": "manufacturing equipment room" - }, - { - "id": 77, - "space_type": "manufacturing extra high bay", - "lighting_subspace_type": "manufacturing_extra_high_bay", - "ventilation_subspace_type": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", - "plug_load_subspace_type": null - }, - { - "id": 78, - "space_type": "manufacturing high bay", - "lighting_subspace_type": "manufacturing_high_bay", - "ventilation_subspace_type": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", - "plug_load_subspace_type": null - }, - { - "id": 79, - "space_type": "manufacturing low bay", - "lighting_subspace_type": "manufacturing_low_bay", - "ventilation_subspace_type": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", - "plug_load_subspace_type": "manufacturing low bay" - }, - { - "id": 80, - "space_type": "manufacturing control", - "lighting_subspace_type": "manufacturing_control", - "ventilation_subspace_type": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", - "plug_load_subspace_type": null - }, - { - "id": 81, - "space_type": "museum exhibit area", - "lighting_subspace_type": "museum_exhibit_area", - "ventilation_subspace_type": "public_assembly_spaces_museums_galleries", - "plug_load_subspace_type": "museum exhibit area" - }, - { - "id": 82, - "space_type": "museum restoration", - "lighting_subspace_type": "museum_restoration", - "ventilation_subspace_type": "public_assembly_spaces_museums_galleries", - "plug_load_subspace_type": "museum restoration" - }, - { - "id": 83, - "space_type": "performing arts dressing room", - "lighting_subspace_type": "performing_arts_dressing_room", - "ventilation_subspace_type": "retail_mall_common_areas", - "plug_load_subspace_type": "performing arts dressing room" - }, - { - "id": 84, - "space_type": "office - enclosed <= 250 sf", - "lighting_subspace_type": "office_enclosed_small", - "ventilation_subspace_type": "office_buildings_office_space", - "plug_load_subspace_type": "office - enclosed <= 250 sf" - }, - { - "id": 85, - "space_type": "office - enclosed > 250 sf", - "lighting_subspace_type": "office_enclosed_large", - "ventilation_subspace_type": "office_buildings_office_space", - "plug_load_subspace_type": "office - enclosed > 250 sf" - }, - { - "id": 86, - "space_type": "office - open", - "lighting_subspace_type": "office_open", - "ventilation_subspace_type": "office_buildings_office_space", - "plug_load_subspace_type": "office - open" - }, - { - "id": 87, - "space_type": "parking area, interior", - "lighting_subspace_type": "parking_area_interior", - "ventilation_subspace_type": "miscellaneous_spaces_transportation_waiting", - "plug_load_subspace_type": "parking area, interior" - }, - { - "id": 88, - "space_type": "pharmacy", - "lighting_subspace_type": "pharmacy", - "ventilation_subspace_type": "miscellaneous_spaces_pharmacy", - "plug_load_subspace_type": "pharmacy" - }, - { - "id": 89, - "space_type": "post office - sorting area", - "lighting_subspace_type": "post_office_sorting_area", - "ventilation_subspace_type": "miscellaneous_spaces_sorting_packing_light_assembly", - "plug_load_subspace_type": "post office - sorting area" - }, - { - "id": 90, - "space_type": "fellowship hall - religious facility", - "lighting_subspace_type": "fellowship_hall_religious_facility", - "ventilation_subspace_type": "public_assembly_spaces_religious_workshop", - "plug_load_subspace_type": "fellowship hall - religious facility" - }, - { - "id": 91, - "space_type": "worship/pulpit/choir area", - "lighting_subspace_type": "worship_pulpit_choir_area", - "ventilation_subspace_type": "public_assembly_spaces_religious_workshop", - "plug_load_subspace_type": "worship/pulpit/choir area" - }, - { - "id": 92, - "space_type": "restroom - all other", - "lighting_subspace_type": "restroom_all_other", - "ventilation_subspace_type": null, - "plug_load_subspace_type": "restroom - all other" - }, - { - "id": 93, - "space_type": "restroom - visually impaired", - "lighting_subspace_type": "restroom_visually_impaired", - "ventilation_subspace_type": null, - "plug_load_subspace_type": null - }, - { - "id": 94, - "space_type": "retail dressing room", - "lighting_subspace_type": "retail_dressing_room", - "ventilation_subspace_type": "retail_mall_common_areas", - "plug_load_subspace_type": null - }, - { - "id": 95, - "space_type": "retail mall concourse", - "lighting_subspace_type": "retail_mall_concourse", - "ventilation_subspace_type": "retail_mall_common_areas", - "plug_load_subspace_type": null - }, - { - "id": 96, - "space_type": "seating area, general", - "lighting_subspace_type": "seating_area_general", - "ventilation_subspace_type": "public_assembly_spaces_auditorium_seating_area", - "plug_load_subspace_type": "seating area, general" - }, - { - "id": 97, - "space_type": "sports arena playing area, class I", - "lighting_subspace_type": "sports_arena_playing_area_class_I", - "ventilation_subspace_type": "sports_entertainment_sports_arena", - "plug_load_subspace_type": null - }, - { - "id": 98, - "space_type": "sports arena playing area, class II", - "lighting_subspace_type": "sports_arena_playing_area_class_II", - "ventilation_subspace_type": "sports_entertainment_sports_arena", - "plug_load_subspace_type": "sports arena playing area, class II" - }, - { - "id": 99, - "space_type": "sports arena playing area, class III", - "lighting_subspace_type": "sports_arena_playing_area_class_III", - "ventilation_subspace_type": "sports_entertainment_sports_arena", - "plug_load_subspace_type": null - }, - { - "id": 100, - "space_type": "sports arena playing area, class IV", - "lighting_subspace_type": "sports_arena_playing_area_class_IV", - "ventilation_subspace_type": "sports_entertainment_sports_arena", - "plug_load_subspace_type": "sports arena playing area, class IV" - }, - { - "id": 101, - "space_type": "sports arena - ring sports area", - "lighting_subspace_type": "sports_arena_ring_sports_area", - "ventilation_subspace_type": "sports_entertainment_sports_arena", - "plug_load_subspace_type": null - }, - { - "id": 102, - "space_type": "sports arena - court sports area", - "lighting_subspace_type": "sports_arena_court_sports_area", - "ventilation_subspace_type": "sports_entertainment_sports_arena", - "plug_load_subspace_type": null - }, - { - "id": 103, - "space_type": "sports arena - indoor playing field", - "lighting_subspace_type": "sports_arena_indoor_playing_field", - "ventilation_subspace_type": "sports_entertainment_sports_arena", - "plug_load_subspace_type": null - }, - { - "id": 104, - "space_type": "stairwell", - "lighting_subspace_type": "stairwell", - "ventilation_subspace_type": "general_conference_corridors", - "plug_load_subspace_type": "stairwell" - }, - { - "id": 105, - "space_type": "storage < 50 sf - all other", - "lighting_subspace_type": "storage_ all_other_small", - "ventilation_subspace_type": "general_conference_storage_rooms", - "plug_load_subspace_type": "storage < 50 sf - all other" - }, - { - "id": 106, - "space_type": "storage 50 to 1000 sf - all other", - "lighting_subspace_type": "storage_ all_other_large", - "ventilation_subspace_type": "general_conference_storage_rooms", - "plug_load_subspace_type": "storage 50 to 1000 sf - all other" - }, - { - "id": 107, - "space_type": "storage < 50 sf - hospital", - "lighting_subspace_type": "storage_hospital_small", - "ventilation_subspace_type": "general_conference_storage_rooms", - "plug_load_subspace_type": "storage < 50 sf - hospital" - }, - { - "id": 108, - "space_type": "storage 50 to 1000 sf - hospital", - "lighting_subspace_type": "storage_hospital_large", - "ventilation_subspace_type": "general_conference_storage_rooms", - "plug_load_subspace_type": "storage 50 to 1000 sf - hospital" - }, - { - "id": 109, - "space_type": "storage - inactive", - "lighting_subspace_type": "storage_inactive", - "ventilation_subspace_type": "general_conference_storage_rooms", - "plug_load_subspace_type": "storage - inactive" - }, - { - "id": 110, - "space_type": "storage, inactive - museum", - "lighting_subspace_type": "storage_inactive_museum", - "ventilation_subspace_type": "general_conference_storage_rooms", - "plug_load_subspace_type": null - }, - { - "id": 111, - "space_type": "airport concourse", - "lighting_subspace_type": "airport_concourse", - "ventilation_subspace_type": "office_buildings_reception_areas", - "plug_load_subspace_type": "airport concourse" - }, - { - "id": 112, - "space_type": "baggage/carousel", - "lighting_subspace_type": "baggage_carousel", - "ventilation_subspace_type": "office_buildings_reception_areas", - "plug_load_subspace_type": "baggage/carousel" - }, - { - "id": 113, - "space_type": "transportation ticket counter", - "lighting_subspace_type": "transportation_ticket_counter", - "ventilation_subspace_type": "office_buildings_reception_areas", - "plug_load_subspace_type": "transportation ticket counter" - }, - { - "id": 114, - "space_type": "vehicular maintenance", - "lighting_subspace_type": "vehicular_maintenance", - "ventilation_subspace_type": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", - "plug_load_subspace_type": "vehicular maintenance" - }, - { - "id": 115, - "space_type": "warehouse - bulk storage", - "lighting_subspace_type": "warehouse_bulk_storage", - "ventilation_subspace_type": "miscellaneous_spaces_warehouses", - "plug_load_subspace_type": "warehouse - bulk storage" - }, - { - "id": 116, - "space_type": "warehouse - fine storage", - "lighting_subspace_type": "warehouse_fine_storage", - "ventilation_subspace_type": "miscellaneous_spaces_warehouses", - "plug_load_subspace_type": "warehouse - fine storage" - }, - { - "id": 117, - "space_type": "workshop", - "lighting_subspace_type": "workshop", - "ventilation_subspace_type": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", - "plug_load_subspace_type": "workshop" - }, - { - "id": 118, - "space_type": "sales", - "lighting_subspace_type": "sales", - "ventilation_subspace_type": "retail_sales", - "plug_load_subspace_type": "sales" - }, - { - "id": 119, - "space_type": "sales - display type 1", - "lighting_subspace_type": "sales_display_type_1", - "ventilation_subspace_type": "retail_sales", - "plug_load_subspace_type": null - }, - { - "id": 120, - "space_type": "sales - display type 2", - "lighting_subspace_type": "sales_display_type_2", - "ventilation_subspace_type": "retail_sales", - "plug_load_subspace_type": null - }, - { - "id": 121, - "space_type": "sales - display type 3", - "lighting_subspace_type": "sales_display_type_3", - "ventilation_subspace_type": "retail_sales", - "plug_load_subspace_type": null - }, - { - "id": 122, - "space_type": "sales - display type 4", - "lighting_subspace_type": "sales_display_type_4", - "ventilation_subspace_type": "retail_sales", - "plug_load_subspace_type": null - }, - { - "id": 123, - "space_type": "guest room - highway", - "lighting_subspace_type": "guest_room", - "ventilation_subspace_type": "hotels_motels_resorts_dormitories_barracks_sleeping_areas", - "plug_load_subspace_type": null - }, - { - "id": 124, - "space_type": "lodging dining - highway", - "lighting_subspace_type": "dining_general", - "ventilation_subspace_type": "food_beverage_service_restaurant_dining_rooms", - "plug_load_subspace_type": null - }, - { - "id": 125, - "space_type": "audience seating - classroom/lecture/training", - "lighting_subspace_type": "audience_seating_general", - "ventilation_subspace_type": "public_assembly_spaces_auditorium_seating_area", - "plug_load_subspace_type": null - }, - { - "id": 126, - "space_type": "audience seating - conference/meeting/multipurpose", - "lighting_subspace_type": "audience_seating_general", - "ventilation_subspace_type": "public_assembly_spaces_auditorium_seating_area", - "plug_load_subspace_type": null - }, - { - "id": 127, - "space_type": "audience seating - corridor/transition", - "lighting_subspace_type": "audience_seating_general", - "ventilation_subspace_type": "public_assembly_spaces_auditorium_seating_area", - "plug_load_subspace_type": null - }, - { - "id": 128, - "space_type": "guest room - bathroom", - "lighting_subspace_type": "guest_room", - "ventilation_subspace_type": "hotels_motels_resorts_dormitories_barracks_sleeping_areas", - "plug_load_subspace_type": null - } -] \ No newline at end of file diff --git a/data/openstudio_standards_data/initial_data/general_building_space_type_full.csv b/data/openstudio_standards_data/initial_data/general_building_space_type_full.csv deleted file mode 100644 index 38de66d099..0000000000 --- a/data/openstudio_standards_data/initial_data/general_building_space_type_full.csv +++ /dev/null @@ -1,221 +0,0 @@ -id,building_type,space_type,lighting_space_type_name,ventilation_space_type_name -1,FullServiceRestaurant,Kitchen,kitchen,food_beverage_service_kitchen -2,FullServiceRestaurant,Dining,dining_family,food_beverage_service_restaurant_dining_rooms -3,FullServiceRestaurant,Attic,, -4,HighriseApartment,Apartment,bam_multifamily,hotels_motels_resorts_dormitories_bedroom_living_room -5,HighriseApartment,Apartment_topfloor_NS,bam_multifamily,hotels_motels_resorts_dormitories_bedroom_living_room -6,HighriseApartment,Apartment_topfloor_WE,bam_multifamily,hotels_motels_resorts_dormitories_bedroom_living_room -7,HighriseApartment,Corridor,corridor_general,transient_residential_common_corridors -8,HighriseApartment,Corridor_topfloor,corridor_general,transient_residential_common_corridors -9,HighriseApartment,Office,office_enclosed_small,hotels_motels_resorts_dormitories_multi_purpose_assembly -10,Hospital,Basement,bam_hospital,outpatient_health_care_facilities_general_examination_room -11,Hospital,Corridor,corridor_hospital,general_conference_corridors -12,Hospital,Dining,dining_general,food_beverage_service_restaurant_dining_rooms -13,Hospital,ER_Exam,exam_treatment,outpatient_health_care_facilities_general_examination_room -14,Hospital,ER_NurseStn,nurses_station,outpatient_health_care_facilities_psychiatric_consultation_room -15,Hospital,ER_Trauma,emergency_room,outpatient_health_care_facilities_general_examination_room -16,Hospital,ER_Triage,emergency_room,outpatient_health_care_facilities_general_examination_room -17,Hospital,ICU_NurseStn,nurses_station,outpatient_health_care_facilities_urgent_care_examination_room -18,Hospital,ICU_Open,recovery,outpatient_health_care_facilities_urgent_care_examination_room -19,Hospital,Lab,laboratory_classroom,educational_facilities_science_laboratories -20,Hospital,Lobby,lobby_general,public_assembly_spaces_lobbies -21,Hospital,NurseStn,nurses_station,outpatient_health_care_facilities_psychiatric_consultation_room -22,Hospital,OR,operating_room,outpatient_health_care_facilities_general_examination_room -23,Hospital,PatCorridor,corridor_hospital,general_conference_corridors -24,Hospital,PatRoom,patient_room,outpatient_health_care_facilities_physical_therapy_individual_room -25,Hospital,PhysTherapy,physical_therapy,outpatient_health_care_facilities_physical_therapy_exercise_area -26,Hospital,Radiology,imaging,outpatient_health_care_facilities_class_1_imaging_rooms -27,Hospital,Kitchen,kitchen,food_beverage_service_kitchen -28,Hospital,ICU_PatRm,patient_room,outpatient_health_care_facilities_physical_therapy_individual_room -29,Hospital,Office,office_enclosed_small,office_buildings_office_space -30,Hospital,HospitalOfficeFlr1,office_enclosed_small,office_buildings_office_space -31,Hospital,HospitalOfficeFlr5,office_enclosed_small,office_buildings_office_space -32,LargeHotel,Kitchen,kitchen,food_beverage_service_kitchen -33,LargeHotel,Banquet,dining_hotel,general_conference_meeting -34,LargeHotel,Basement,bam_hotel,hotels_motels_resorts_dormitories_multi_purpose_assembly -35,LargeHotel,Cafe,dining_hotel,food_beverage_service_cafeteria_fast_food_dining -36,LargeHotel,Corridor,corridor_general,general_conference_corridors -37,LargeHotel,Corridor2,corridor_general,general_conference_corridors -38,LargeHotel,GuestRoom,guest_room,hotels_motels_resorts_dormitories_bedroom_living_room -39,LargeHotel,GuestRoom2,guest_room,hotels_motels_resorts_dormitories_bedroom_living_room -40,LargeHotel,GuestRoom3,guest_room,hotels_motels_resorts_dormitories_bedroom_living_room -41,LargeHotel,GuestRoom4,guest_room,hotels_motels_resorts_dormitories_bedroom_living_room -42,LargeHotel,Laundry,laundry_washing,hotels_motels_resorts_dormitories_laundry_rooms -43,LargeHotel,Lobby,lobby_hotel,hotels_motels_resorts_dormitories_lobbies_prefunction -44,LargeHotel,Mechanical,electrical_mechanical,general_conference_corridors -45,LargeHotel,Retail,sales,retail_sales -46,LargeHotel,Retail2,sales,retail_sales -47,LargeHotel,Storage,storage_ all_other_small,office_buildings_occupiable_storage_rooms -48,MidriseApartment,Apartment,bam_multifamily,hotels_motels_resorts_dormitories_bedroom_living_room -49,MidriseApartment,Apartment_topfloor_NS,bam_multifamily,hotels_motels_resorts_dormitories_bedroom_living_room -50,MidriseApartment,Apartment_topfloor_WE,bam_multifamily,hotels_motels_resorts_dormitories_bedroom_living_room -51,MidriseApartment,Corridor,corridor_general,transient_residential_common_corridors -52,MidriseApartment,Corridor_topfloor,corridor_general,transient_residential_common_corridors -53,MidriseApartment,Office,office_enclosed_small,office_buildings_office_space -54,Office,OfficeLarge Data Center,computer_room,miscellaneous_spaces_computer -55,Office,OfficeLarge Main Data Center,computer_room,miscellaneous_spaces_computer -56,Office,WholeBuilding - Sm Office,bam_office,office_buildings_office_space -57,Office,WholeBuilding - Md Office,bam_office,office_buildings_office_space -58,Office,WholeBuilding - Lg Office,bam_office,office_buildings_office_space -59,Office,WholeBuilding - Lg Office-basement,bam_office,office_buildings_office_space -60,Office,Attic,, -61,Office,General,bam_office,office_buildings_office_space -62,Office,Vending,corridor_general,general_conference_corridors -63,Office,Storage,storage_ all_other_small,office_buildings_occupiable_storage_rooms -64,Office,Stair,stairway,general_conference_corridors -65,Office,Restroom,restroom_visually_impaired,general_conference_corridors -66,Office,PrintRoom,office_enclosed_small,general_conference_corridors -67,Office,OpenOffice,office_open,office_buildings_office_space -68,Office,Lobby,lobby_general,public_assembly_spaces_lobbies -69,Office,IT_Room,office_enclosed_small,general_conference_corridors -70,Office,Elec/MechRoom,electrical_mechanical,general_conference_corridors -71,Office,Corridor,corridor_general,general_conference_corridors -72,Office,Conference,conference_meeting_multipurpose,general_conference_meeting -73,Office,ClosedOffice,office_enclosed_small,office_buildings_office_space -74,Office,BreakRoom,lounge_breakroom_general,office_buildings_reception_areas -75,Office,Elevator Lobby,lobby_general,public_assembly_spaces_lobbies -76,Office,Elevator Machine Room,electrical_mechanical,general_conference_corridors -77,Office,Main Electrical,electrical_mechanical,general_conference_corridors -78,Office,Main Mechanical,electrical_mechanical,general_conference_corridors -79,Office,Dining,dining_general,food_beverage_service_cafeteria_fast_food_dining -80,Office,Classroom,classroom_lecture_training_general,educational_facilities_lecture_classroom -81,Office,MediumOffice - Storage,storage_ all_other_small,office_buildings_occupiable_storage_rooms -82,Office,MediumOffice - Stair,stairway,general_conference_corridors -83,Office,MediumOffice - Restroom,restroom_visually_impaired,general_conference_corridors -84,Office,MediumOffice - OpenOffice,office_open,office_buildings_office_space -85,Office,MediumOffice - Lobby,lobby_general,public_assembly_spaces_lobbies -86,Office,MediumOffice - Elec/MechRoom,electrical_mechanical,general_conference_corridors -87,Office,MediumOffice - Corridor,corridor_general,general_conference_corridors -88,Office,MediumOffice - Conference,conference_meeting_multipurpose,general_conference_meeting -89,Office,MediumOffice - ClosedOffice,office_enclosed_small,office_buildings_office_space -90,Office,MediumOffice - Breakroom,lounge_breakroom_general,office_buildings_reception_areas -91,Office,MediumOffice - Dining,dining_general,food_beverage_service_cafeteria_fast_food_dining -92,Office,MediumOffice - Classroom,classroom_lecture_training_general,educational_facilities_lecture_classroom -93,Office,SmallOffice - Attic,, -94,Office,SmallOffice - Storage,storage_ all_other_small,office_buildings_occupiable_storage_rooms -95,Office,SmallOffice - Stair,stairway,general_conference_corridors -96,Office,SmallOffice - Restroom,restroom_visually_impaired,general_conference_corridors -97,Office,SmallOffice - OpenOffice,office_open,office_buildings_office_space -98,Office,SmallOffice - Lobby,lobby_general,public_assembly_spaces_lobbies -99,Office,SmallOffice - Elec/MechRoom,electrical_mechanical,general_conference_corridors -100,Office,SmallOffice - Corridor,corridor_general,general_conference_corridors -101,Office,SmallOffice - Conference,conference_meeting_multipurpose,general_conference_meeting -102,Office,SmallOffice - ClosedOffice,office_enclosed_small,office_buildings_office_space -103,Office,SmallOffice - Breakroom,lounge_breakroom_general,office_buildings_reception_areas -104,Office,SmallOffice - Dining,dining_general,food_beverage_service_cafeteria_fast_food_dining -105,Office,SmallOffice - Classroom,classroom_lecture_training_general,educational_facilities_lecture_classroom -106,Office,WholeBuilding - Lg Office-others,bam_office,office_buildings_office_space -107,Office,WholeBuilding - Lg Office-basement,bam_office,office_buildings_office_space -108,Office,Elevator Shaft,electrical_mechanical,general_conference_corridors -109,Outpatient,Anesthesia,exam_treatment,outpatient_health_care_facilities_general_examination_room -110,Outpatient,BioHazard,storage_hospital_small,office_buildings_occupiable_storage_rooms -111,Outpatient,Cafe,dining_general,food_beverage_service_cafeteria_fast_food_dining -112,Outpatient,CleanWork,exam_treatment,outpatient_health_care_facilities_general_examination_room -113,Outpatient,Conference,conference_meeting_multipurpose,general_conference_meeting -114,Outpatient,DressingRoom,office_enclosed_small,office_buildings_office_space -115,Outpatient,Elec/MechRoom,electrical_mechanical,general_conference_corridors -116,Outpatient,ElevatorPumpRoom,electrical_mechanical,general_conference_corridors -117,Outpatient,Exam,exam_treatment,outpatient_health_care_facilities_general_examination_room -118,Outpatient,Hall,corridor_hospital,general_conference_corridors -119,Outpatient,Hall_infil,corridor_hospital,general_conference_corridors -120,Outpatient,IT_Room,office_enclosed_small,office_buildings_office_space -121,Outpatient,Janitor,storage_hospital_small,office_buildings_occupiable_storage_rooms -122,Outpatient,Lobby,lobby_general,public_assembly_spaces_lobbies -123,Outpatient,LockerRoom,lounge_breakroom_healthcare_facility,public_assembly_spaces_lobbies -124,Outpatient,Lounge,lounge_breakroom_healthcare_facility,public_assembly_spaces_lobbies -125,Outpatient,MedGas,storage_hospital_small,office_buildings_occupiable_storage_rooms -126,Outpatient,MRI,imaging,outpatient_health_care_facilities_class_1_imaging_rooms -127,Outpatient,MRI_Control,imaging,outpatient_health_care_facilities_class_1_imaging_rooms -128,Outpatient,NurseStation,nurses_station,outpatient_health_care_facilities_psychiatric_consultation_room -129,Outpatient,OutpatientFloor2Work,office_enclosed_small,office_buildings_office_space -130,Outpatient,Office,office_enclosed_small,office_buildings_office_space -131,Outpatient,OR,operating_room,outpatient_health_care_facilities_general_examination_room -132,Outpatient,PACU,recovery,outpatient_health_care_facilities_physical_therapy_exercise_area -133,Outpatient,PhysicalTherapy,physical_therapy,outpatient_health_care_facilities_physical_therapy_exercise_area -134,Outpatient,PreOp,patient_room,outpatient_health_care_facilities_physical_therapy_individual_room -135,Outpatient,ProcedureRoom,emergency_room,outpatient_health_care_facilities_general_examination_room -136,Outpatient,Reception,lobby_general,public_assembly_spaces_lobbies -137,Outpatient,Stair,stairway,general_conference_corridors -138,Outpatient,Soil Work,exam_treatment,outpatient_health_care_facilities_general_examination_room -139,Outpatient,Toilet,restroom_visually_impaired,general_conference_corridors -140,Outpatient,Undeveloped,storage_hospital_small,office_buildings_occupiable_storage_rooms -141,Outpatient,Xray,imaging,outpatient_health_care_facilities_class_1_imaging_rooms -142,PrimarySchool,Cafeteria,dining_general,food_beverage_service_cafeteria_fast_food_dining -143,PrimarySchool,Classroom,classroom_lecture_training_general,educational_facilities_classroom_young -144,PrimarySchool,ComputerRoom,classroom_lecture_training_general,educational_facilities_computer_lab -145,PrimarySchool,Corridor,corridor_general,general_conference_corridors -146,PrimarySchool,Gym,gymnasium_exercise_area,sports_entertainment_gym_stadium -147,PrimarySchool,Kitchen,kitchen,food_beverage_service_kitchen -148,PrimarySchool,Library,library_reading,educational_facilities_libraries -149,PrimarySchool,Lobby,lobby_general,public_assembly_spaces_lobbies -150,PrimarySchool,Mechanical,electrical_mechanical,general_conference_corridors -151,PrimarySchool,Office,office_enclosed_small,office_buildings_office_space -152,PrimarySchool,Restroom,restroom_visually_impaired,general_conference_corridors -153,QuickServiceRestaurant,Dining,dining_general,food_beverage_service_cafeteria_fast_food_dining -154,QuickServiceRestaurant,Attic,, -155,QuickServiceRestaurant,Kitchen,kitchen,food_beverage_service_kitchen -156,Retail,Back_Space,storage_ all_other_small,retail_sales -157,Retail,Entry,lobby_general,retail_sales -158,Retail,Point_of_Sale,sales,retail_sales -159,Retail,Retail,sales,retail_sales -160,Retail,Core_Retail,sales,retail_sales -161,Retail,Front_Retail,sales,retail_sales -162,SecondarySchool,Auditorium,audience_seating_general,public_assembly_spaces_auditorium_seating_area -163,SecondarySchool,Cafeteria,dining_general,food_beverage_service_cafeteria_fast_food_dining -164,SecondarySchool,Classroom,classroom_lecture_training_general,educational_facilities_classroom_old -165,SecondarySchool,ComputerRoom,classroom_lecture_training_general,educational_facilities_computer_lab -166,SecondarySchool,Corridor,corridor_general,general_conference_corridors -167,SecondarySchool,Gym,gymnasium_exercise_area,sports_entertainment_gym_stadium -168,SecondarySchool,Library,library_reading,educational_facilities_libraries -169,SecondarySchool,Lobby,lobby_general,public_assembly_spaces_lobbies -170,SecondarySchool,Mechanical,electrical_mechanical,general_conference_corridors -171,SecondarySchool,Office,office_enclosed_small,office_buildings_office_space -172,SecondarySchool,Restroom,restroom_visually_impaired,general_conference_corridors -173,SecondarySchool,Kitchen,kitchen,food_beverage_service_kitchen -174,SmallHotel,GuestRoom,guest_room,hotels_motels_resorts_dormitories_bedroom_living_room -175,SmallHotel,Corridor,corridor_general,general_conference_corridors -176,SmallHotel,Corridor4,corridor_general,general_conference_corridors -177,SmallHotel,Elec/MechRoom,electrical_mechanical,general_conference_corridors -178,SmallHotel,ElevatorCore,lobby_general,general_conference_corridors -179,SmallHotel,ElevatorCore4,lobby_general,general_conference_corridors -180,SmallHotel,Exercise,gymnasium_exercise_area,sports_entertainment_gym_stadium -181,SmallHotel,GuestRoom123Occ,guest_room,hotels_motels_resorts_dormitories_bedroom_living_room -182,SmallHotel,GuestRoom123Vac,guest_room,hotels_motels_resorts_dormitories_bedroom_living_room -183,SmallHotel,GuestRoom4Occ,guest_room,hotels_motels_resorts_dormitories_bedroom_living_room -184,SmallHotel,GuestRoom4Vac,guest_room,hotels_motels_resorts_dormitories_bedroom_living_room -185,SmallHotel,Laundry,laundry_washing,hotels_motels_resorts_dormitories_laundry_rooms -186,SmallHotel,Mechanical,electrical_mechanical,general_conference_corridors -187,SmallHotel,Meeting,conference_meeting_multipurpose,general_conference_meeting -188,SmallHotel,Office,office_enclosed_small,office_buildings_office_space -189,SmallHotel,PublicRestroom,restroom_visually_impaired,general_conference_corridors -190,SmallHotel,StaffLounge,lounge_breakroom_general,general_conference_meeting -191,SmallHotel,Stair,stairway,general_conference_corridors -192,SmallHotel,Stair4,stairway,general_conference_corridors -193,SmallHotel,Storage,storage_ all_other_small,office_buildings_occupiable_storage_rooms -194,SmallHotel,Storage4Front,storage_ all_other_small,office_buildings_occupiable_storage_rooms -195,SmallHotel,Storage4Rear,storage_ all_other_small,office_buildings_occupiable_storage_rooms -196,SmallHotel,GuestLounge,lounge_breakroom_general,public_assembly_spaces_lobbies -197,StripMall,Strip mall - type 0A,sales,retail_sales -198,StripMall,Strip mall - type 0B,sales,retail_sales -199,StripMall,Strip mall - type 1,bam_retail,retail_sales -200,StripMall,Strip mall - type 2,bam_retail,retail_sales -201,StripMall,Strip mall - type 3,bam_retail,retail_sales -202,SuperMarket,Meeting,conference_meeting_multipurpose,general_conference_meeting -203,SuperMarket,Dining,dining_general,food_beverage_service_cafeteria_fast_food_dining -204,SuperMarket,Restroom,restroom_visually_impaired,general_conference_corridors -205,SuperMarket,Elec/MechRoom,electrical_mechanical,general_conference_corridors -206,SuperMarket,Corridor,corridor_general,general_conference_corridors -207,SuperMarket,Deli,sales,retail_supermarket -208,SuperMarket,Bakery,kitchen,retail_supermarket -209,SuperMarket,Vestibule,lobby_general,office_buildings_main_entry_lobbies -210,SuperMarket,Sales,sales,retail_supermarket -211,SuperMarket,Produce,sales,retail_supermarket -212,SuperMarket,DryStorage,storage_ all_other_small,office_buildings_occupiable_storage_rooms -213,SuperMarket,Office,office_enclosed_small,office_buildings_office_space -214,Warehouse,Office,office_enclosed_small,office_buildings_office_space -215,Warehouse,Fine,warehouse_fine_storage,miscellaneous_spaces_warehouses -216,Warehouse,Bulk,warehouse_bulk_storage,miscellaneous_spaces_warehouses -217,LargeHotel,GuestRoom5,guest_room,hotels_motels_resorts_dormitories_bedroom_living_room -218,LargeHotel,GuestRoom6,guest_room,hotels_motels_resorts_dormitories_bedroom_living_room -219,LargeHotel,GuestRoom7,guest_room,hotels_motels_resorts_dormitories_bedroom_living_room -220,LargeHotel,GuestRoom8,guest_room,hotels_motels_resorts_dormitories_bedroom_living_room diff --git a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_boilers_90_1.csv b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_boilers_90_1.csv deleted file mode 100644 index 1580f685cb..0000000000 --- a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_boilers_90_1.csv +++ /dev/null @@ -1,22 +0,0 @@ -id,template,fluid_type,fuel_type,condensing,condensing_control,minimum_capacity,maximum_capacity,start_date,end_date,minimum_annual_fuel_utilization_efficiency,minimum_thermal_efficiency,minimum_combustion_efficiency,efffplr,annotation -1,90.1-2004,Hot Water,Gas,,,0,299999,9/9/1919,9/9/2999,0.8,,,Boiler with No Minimum Turndown,From 90.1-2004 -2,90.1-2004,Hot Water,Gas,,,300000,249999999,9/9/1919,9/9/2999,,0.75,,Boiler with No Minimum Turndown,From 90.1-2004 -3,90.1-2004,Hot Water,Gas,,,250000000,9999999999,9/9/1919,9/9/2999,,,0.8,Boiler with No Minimum Turndown,From 90.1-2004 -4,90.1-2007,Hot Water,Gas,,,0,299999,9/9/1919,9/9/2999,0.8,,,Boiler with No Minimum Turndown,From 90.1-2007 -5,90.1-2007,Hot Water,Gas,,,300000,249999999,9/9/1919,9/9/2999,,0.8,,Boiler with No Minimum Turndown,From 90.1-2007 -6,90.1-2007,Hot Water,Gas,,,250000000,9999999999,9/9/1919,9/9/2999,,,0.82,Boiler with No Minimum Turndown,From 90.1-2007 -7,90.1-2010,Hot Water,Gas,,,0,299999,9/9/1919,9/9/2999,0.8,,,Boiler with No Minimum Turndown,From 90.1-2010 -8,90.1-2010,Hot Water,Gas,,,300000,249999999,9/9/1919,9/9/2999,,0.8,,Boiler with No Minimum Turndown,From 90.1-2010 -9,90.1-2010,Hot Water,Gas,,,250000000,9999999999,9/9/1919,9/9/2999,,,0.82,Boiler with No Minimum Turndown,From 90.1-2010 -10,90.1-2013,Hot Water,Gas,,,0,299999,9/9/1919,9/9/2999,0.82,,,Boiler with No Minimum Turndown,From 90.1-2013 -11,90.1-2013,Hot Water,Gas,,,300000,999999,9/9/1919,9/9/2999,,0.8,,Boiler with No Minimum Turndown,From 90.1-2013 -12,90.1-2013,Hot Water,Gas,,,1000000,249999999,9/9/1919,9/9/2999,,0.8,,Boiler with Minimum Turndown,From 90.1-2013 -13,90.1-2013,Hot Water,Gas,,,250000000,9999999999,9/9/1919,9/9/2999,,,0.82,Boiler with Minimum Turndown,From 90.1-2013 -14,90.1-2016,Hot Water,Gas,,,0,299999,9/9/1919,9/9/2999,0.82,,,Boiler with No Minimum Turndown,From 90.1-2016 -15,90.1-2016,Hot Water,Gas,,,300000,999999,9/9/1919,9/9/2999,,0.8,,Boiler with No Minimum Turndown,From 90.1-2016 -16,90.1-2016,Hot Water,Gas,,,1000000,249999999,9/9/1919,9/9/2999,,0.8,,Boiler with Minimum Turndown,From 90.1-2016 -17,90.1-2016,Hot Water,Gas,,,250000000,9999999999,9/9/1919,9/9/2999,,,0.82,Boiler with Minimum Turndown,From 90.1-2016 -18,90.1-2019,Hot Water,Gas,,,0,299999,9/9/1919,9/9/2999,0.84,,,Boiler with No Minimum Turndown,From 90.1-2019 -19,90.1-2019,Hot Water,Gas,,,300000,999999,9/9/1919,9/9/2999,,0.8,,Boiler with No Minimum Turndown,From 90.1-2019 -20,90.1-2019,Hot Water,Gas,,,1000000,249999999,9/9/1919,9/9/2999,,0.8,,Boiler with Minimum Turndown,From 90.1-2019 -21,90.1-2019,Hot Water,Gas,,,250000000,9999999999,9/9/1919,9/9/2999,,,0.82,Boiler with Minimum Turndown,From 90.1-2019 diff --git a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_chillers_90_1.csv b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_chillers_90_1.csv deleted file mode 100644 index c904371f30..0000000000 --- a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_chillers_90_1.csv +++ /dev/null @@ -1,163 +0,0 @@ -template,cooling_type,condenser_type,compressor_type,absorption_type,variable_speed_drive,minimum_capacity,maximum_capacity,start_date,end_date,minimum_full_load_efficiency,minimum_integrated_part_load_value,capft,eirft,eirfplr,annotation -90.1-2004,AirCooled,WithCondenser,,,,0,9999,9/9/1919,9/9/2999,1.256,1.153,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR, -90.1-2004,AirCooled,WithoutCondenser,,,,0,9999,9/9/1919,9/9/2999,1.135,1.019,ChlrAirRecipQRatio_fTchwsToadbSI,ChlrAirRecipEIRRatio_fTchwsToadbSI,ChlrAirRecipEIRRatio_fQRatio, -90.1-2004,AirCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.862,,,,, -90.1-2007,AirCooled,WithCondenser,,,,0,9999,9/9/1919,9/9/2999,1.29,1.164,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Form 90.1-2007 Table 6.8.1A -90.1-2010,AirCooled,WithCondenser,,,,0,149.99,9/9/1919,9/9/2999,1.255,0.941,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR, -90.1-2010,AirCooled,WithCondenser,,,,150,9999,9/9/1919,9/9/2999,1.255,0.941,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR, -90.1-2010,AirCooled,WithoutCondenser,,,,0,9999,9/9/1919,9/9/2999,1.255,0.941,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR, -90.1-2010,AirCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.862,,,,, -90.1-2013,AirCooled,WithCondenser,,,,0,149.99,9/9/1919,12/31/2014,1.25,0.96,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies -90.1-2013,AirCooled,WithCondenser,,,,150,9999,9/9/1919,12/31/2014,1.25,0.94,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies -90.1-2013,AirCooled,WithoutCondenser,,,,0,149.99,9/9/1919,12/31/2014,1.25,0.96,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,AirCooled,WithoutCondenser,,,,150,9999,9/9/1919,12/31/2014,1.25,0.94,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,AirCooled,,,Single Effect,,0,9999,9/9/1919,12/31/2014,5.862,,,,,Path A Efficiencies -90.1-2013,AirCooled,WithCondenser,,,,0,149.99,1/1/2015,12/31/2014,1.188,0.876,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies -90.1-2013,AirCooled,WithCondenser,,,,150,9999,1/1/2015,9/9/2999,1.188,0.857,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies -90.1-2013,AirCooled,WithoutCondenser,,,,0,149.99,1/1/2015,9/9/2999,1.188,0.876,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,AirCooled,WithoutCondenser,,,,150,9999,1/1/2015,9/9/2999,1.188,0.857,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,AirCooled,,,Single Effect,,0,9999,1/1/2015,9/9/2999,5.862,,,,,Path A Efficiencies -90.1-2004,WaterCooled,,Reciprocating,,,0,149.99,9/9/1919,9/9/2999,0.837,0.696,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, -90.1-2004,WaterCooled,,Reciprocating,,,150,9999,9/9/1919,9/9/2999,0.837,0.696,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, -90.1-2004,WaterCooled,,Rotary Screw,,,0,149.99,9/9/1919,9/9/2999,0.79,0.676,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, -90.1-2004,WaterCooled,,Rotary Screw,,,150,299.99,9/9/1919,9/9/2999,0.718,0.628,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, -90.1-2004,WaterCooled,,Rotary Screw,,,300,9999,9/9/1919,9/9/2999,0.639,0.572,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, -90.1-2004,WaterCooled,,Scroll,,,0,149.99,9/9/1919,9/9/2999,0.79,0.676,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, -90.1-2004,WaterCooled,,Scroll,,,150,299.99,9/9/1919,9/9/2999,0.718,0.628,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, -90.1-2004,WaterCooled,,Scroll,,,300,9999,9/9/1919,9/9/2999,0.639,0.572,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, -90.1-2004,WaterCooled,,Centrifugal,,,150,299.99,9/9/1919,9/9/2999,0.634,0.596,WaterCooled_Centrifugal_Chiller_LT150_2004_CAPFT,WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio, -90.1-2004,WaterCooled,,Centrifugal,,,0,149.99,9/9/1919,9/9/2999,0.703,0.67,WaterCooled_Centrifugal_Chiller_LT150_2004_CAPFT,WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio, -90.1-2004,WaterCooled,,Centrifugal,,,300,9999,9/9/1919,9/9/2999,0.577,0.55,WaterCooled_Centrifugal_Chiller_GT150_2004_CAPFT,WaterCooled_Centrifugal_Chiller_GT150_2004_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio, -90.1-2004,WaterCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.024,,,,, -90.1-2007,WaterCooled,,Reciprocating,,,0,74.99,9/9/1919,9/9/2999,0.78,0.63,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Reciprocating,,,75,149.99,9/9/1919,9/9/2999,0.775,0.615,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Reciprocating,,,150,299.99,9/9/1919,9/9/2999,0.68,0.58,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Reciprocating,,,300,9999,9/9/1919,9/9/2999,0.62,0.54,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Scroll,,,0,74.99,9/9/1919,9/9/2999,0.78,0.63,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Scroll,,,75,149.99,9/9/1919,9/9/2999,0.775,0.615,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Scroll,,,150,299.99,9/9/1919,9/9/2999,0.68,0.58,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Scroll,,,300,9999,9/9/1919,9/9/2999,0.62,0.54,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Rotary Screw,,,0,74.99,9/9/1919,9/9/2999,0.78,0.63,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Rotary Screw,,,75,149.99,9/9/1919,9/9/2999,0.775,0.615,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Rotary Screw,,,150,299.99,9/9/1919,9/9/2999,0.68,0.58,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Rotary Screw,,,300,9999,9/9/1919,9/9/2999,0.62,0.54,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Centrifugal,,,0,149.99,9/9/1919,9/9/2999,0.634,0.596,WaterCooled_Centrifugal_Chiller_LT150_2004_CAPFT,WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Centrifugal,,,150,299.99,9/9/1919,9/9/2999,0.634,0.596,WaterCooled_Centrifugal_Chiller_LT150_2004_CAPFT,WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Centrifugal,,,300,599.99,9/9/1919,9/9/2999,0.576,0.549,WaterCooled_Centrifugal_Chiller_GT150_2004_CAPFT,WaterCooled_Centrifugal_Chiller_GT150_2004_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Centrifugal,,,600,9999,9/9/1919,9/9/2999,0.57,0.539,WaterCooled_Centrifugal_Chiller_GT150_2004_CAPFT,WaterCooled_Centrifugal_Chiller_GT150_2004_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Reciprocating,,,0,74.99,9/9/1919,9/9/2999,0.78,0.63,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Reciprocating,,,75,149.99,9/9/1919,9/9/2999,0.775,0.615,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Reciprocating,,,150,299.99,9/9/1919,9/9/2999,0.68,0.58,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Reciprocating,,,300,9999,9/9/1919,9/9/2999,0.62,0.54,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Scroll,,,0,74.99,9/9/1919,9/9/2999,0.78,0.63,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Scroll,,,75,149.99,9/9/1919,9/9/2999,0.775,0.615,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Scroll,,,150,299.99,9/9/1919,9/9/2999,0.68,0.58,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Scroll,,,300,9999,9/9/1919,9/9/2999,0.62,0.54,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Rotary Screw,,,0,74.99,9/9/1919,9/9/2999,0.78,0.63,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Rotary Screw,,,75,149.99,9/9/1919,9/9/2999,0.775,0.615,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Rotary Screw,,,150,299.99,9/9/1919,9/9/2999,0.68,0.58,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Rotary Screw,,,300,9999,9/9/1919,9/9/2999,0.62,0.54,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Centrifugal,,,0,149.99,9/9/1919,9/9/2999,0.634,0.596,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Centrifugal,,,150,299.99,9/9/1919,9/9/2999,0.634,0.596,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Centrifugal,,,300,599.99,9/9/1919,9/9/2999,0.576,0.549,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Centrifugal,,,600,9999,9/9/1919,9/9/2999,0.57,0.539,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.024,,,,, -90.1-2013,WaterCooled,,Reciprocating,,,0,74.99,9/9/1919,12/31/2014,0.78,0.63,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Reciprocating,,,75,149.99,9/9/1919,12/31/2014,0.775,0.615,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Reciprocating,,,150,299.99,9/9/1919,12/31/2014,0.68,0.58,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Reciprocating,,,300,599.99,9/9/1919,12/31/2014,0.62,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Reciprocating,,,600,9999,9/9/1919,12/31/2014,0.62,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Scroll,,,0,74.99,9/9/1919,12/31/2014,0.78,0.63,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Scroll,,,75,149.99,9/9/1919,12/31/2014,0.775,0.615,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Scroll,,,150,299.99,9/9/1919,12/31/2014,0.68,0.58,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Scroll,,,300,599.99,9/9/1919,12/31/2014,0.62,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Scroll,,,600,9999,9/9/1919,12/31/2014,0.62,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Rotary Screw,,,0,74.99,9/9/1919,12/31/2014,0.78,0.63,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Rotary Screw,,,75,149.99,9/9/1919,12/31/2014,0.775,0.615,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Rotary Screw,,,150,299.99,9/9/1919,12/31/2014,0.68,0.58,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Rotary Screw,,,300,599.99,9/9/1919,12/31/2014,0.62,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Rotary Screw,,,600,9999,9/9/1919,12/31/2014,0.62,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Centrifugal,,,0,149.99,9/9/1919,12/31/2014,0.634,0.596,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Centrifugal,,,150,399.99,9/9/1919,12/31/2014,0.634,0.596,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Centrifugal,,,400,599.99,9/9/1919,12/31/2014,0.576,0.549,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Centrifugal,,,600,9999,9/9/1919,12/31/2014,0.57,0.539,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Add but unsure what to put for Minimum full load efficiency and min IPLV -90.1-2013,WaterCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.024,,,,,Path A Efficiencies -90.1-2013,WaterCooled,,Reciprocating,,,0,74.99,1/1/2015,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Reciprocating,,,75,149.99,1/1/2015,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Reciprocating,,,150,299.99,1/1/2015,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Reciprocating,,,300,599.99,1/1/2015,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Reciprocating,,,600,9999,1/1/2015,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Scroll,,,0,74.99,1/1/2015,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Scroll,,,75,149.99,1/1/2015,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Scroll,,,150,299.99,1/1/2015,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Scroll,,,300,599.99,1/1/2015,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Scroll,,,600,9999,1/1/2015,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Rotary Screw,,,0,74.99,1/1/2015,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Rotary Screw,,,75,149.99,1/1/2015,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Rotary Screw,,,150,299.99,1/1/2015,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Rotary Screw,,,300,599.99,1/1/2015,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Rotary Screw,,,600,9999,1/1/2015,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Centrifugal,,,0,149.99,1/1/2015,9/9/2999,0.61,0.55,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Centrifugal,,,150,399.99,1/1/2015,9/9/2999,0.56,0.52,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Centrifugal,,,400,599.99,1/1/2015,9/9/2999,0.56,0.5,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Centrifugal,,,600,9999,1/1/2015,9/9/2999,0.56,0.5,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Add but unsure what to put for Minimum full load efficiency and min IPLV -90.1-2004,,,,Double Effect Indirect Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.35,,,, -90.1-2004,,,,Double Effect Direct Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.517,,,, -90.1-2010,,,,Double Effect Indirect Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.35,,,, -90.1-2010,,,,Double Effect Direct Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.517,,,, -90.1-2013,,,,Double Effect Indirect Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.35,,,,Path A Efficiencies -90.1-2013,,,,Double Effect Direct Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.517,,,,Path A Efficiencies -90.1-2016,AirCooled,WithCondenser,,,,0,149.99,9/9/1919,9/9/2999,1.188,0.876,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies -90.1-2016,AirCooled,WithCondenser,,,,150,9999,9/9/1919,9/9/2999,1.188,0.857,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies -90.1-2016,AirCooled,WithoutCondenser,,,,0,149.99,9/9/1919,9/9/2999,1.188,0.876,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,AirCooled,WithoutCondenser,,,,150,9999,9/9/1919,9/9/2999,1.188,0.857,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,AirCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.862,,,,,Path A Efficiencies -90.1-2016,WaterCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.024,,,,,Path A Efficiencies -90.1-2016,WaterCooled,,Reciprocating,,,0,74.99,9/9/1919,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Reciprocating,,,75,149.99,9/9/1919,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Reciprocating,,,150,299.99,9/9/1919,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Reciprocating,,,300,599.99,9/9/1919,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Reciprocating,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Scroll,,,0,74.99,9/9/1919,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Scroll,,,75,149.99,9/9/1919,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Scroll,,,150,299.99,9/9/1919,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Scroll,,,300,599.99,9/9/1919,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Scroll,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Rotary Screw,,,0,74.99,9/9/1919,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Rotary Screw,,,75,149.99,9/9/1919,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Rotary Screw,,,150,299.99,9/9/1919,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Rotary Screw,,,300,599.99,9/9/1919,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Rotary Screw,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Centrifugal,,,0,149.99,9/9/1919,9/9/2999,0.61,0.55,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Centrifugal,,,150,399.99,9/9/1919,9/9/2999,0.56,0.52,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Centrifugal,,,400,599.99,9/9/1919,9/9/2999,0.56,0.5,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Centrifugal,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,,,,Double Effect Indirect Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.35,,,,Path A Efficiencies -90.1-2016,,,,Double Effect Direct Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.517,,,,Path A Efficiencies -90.1-2019,AirCooled,WithCondenser,,,,0,149.99,9/9/1919,9/9/2999,1.188,0.876,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies -90.1-2019,AirCooled,WithCondenser,,,,150,9999,9/9/1919,9/9/2999,1.188,0.857,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies -90.1-2019,AirCooled,WithoutCondenser,,,,0,149.99,9/9/1919,9/9/2999,1.188,0.876,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,AirCooled,WithoutCondenser,,,,150,9999,9/9/1919,9/9/2999,1.188,0.857,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,AirCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.862,,,,,Path A Efficiencies -90.1-2019,WaterCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.024,,,,,Path A Efficiencies -90.1-2019,WaterCooled,,Reciprocating,,,0,74.99,9/9/1919,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Reciprocating,,,75,149.99,9/9/1919,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Reciprocating,,,150,299.99,9/9/1919,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Reciprocating,,,300,599.99,9/9/1919,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Reciprocating,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Scroll,,,0,74.99,9/9/1919,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Scroll,,,75,149.99,9/9/1919,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Scroll,,,150,299.99,9/9/1919,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Scroll,,,300,599.99,9/9/1919,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Scroll,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Rotary Screw,,,0,74.99,9/9/1919,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Rotary Screw,,,75,149.99,9/9/1919,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Rotary Screw,,,150,299.99,9/9/1919,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Rotary Screw,,,300,599.99,9/9/1919,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Rotary Screw,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Centrifugal,,,0,149.99,9/9/1919,9/9/2999,0.61,0.55,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Centrifugal,,,150,399.99,9/9/1919,9/9/2999,0.56,0.52,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Centrifugal,,,400,599.99,9/9/1919,9/9/2999,0.56,0.5,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Centrifugal,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,,,,Double Effect Indirect Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.35,,,,Path A Efficiencies -90.1-2019,,,,Double Effect Direct Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.517,,,,Path A Efficiencies diff --git a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_furnaces_90_1.csv b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_furnaces_90_1.csv deleted file mode 100644 index 7bbcdb7238..0000000000 --- a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_furnaces_90_1.csv +++ /dev/null @@ -1,13 +0,0 @@ -template,minimum_capacity,maximum_capacity,start_date,end_date,minimum_annual_fuel_utilization_efficiency,minimum_thermal_efficiency,minimum_combustion_efficiency,annotation -90.1-2004,0,224999,9/9/1919,9/9/2999,0.78,0.8,,Table 6.8.1E page 49 -90.1-2004,225000,249999999,9/9/1919,9/9/2999,,,0.8,Table 6.8.1E page 49 -90.1-2007,0,224999,9/9/1919,9/9/2999,0.78,0.8,,Table 6.8.1E page 49 -90.1-2007,225000,249999999,9/9/1919,9/9/2999,,,0.8,Table 6.8.1E page 49 -90.1-2010,0,224999,9/9/1919,9/9/2999,0.78,0.8,,Table 6.8.1E page 62 -90.1-2010,225000,249999999,9/9/1919,9/9/2999,,0.8,,Table 6.8.1E page 62 -90.1-2013,0,224999,9/9/1919,9/9/2999,0.78,0.8,,Table 6.8.1E page 72 -90.1-2013,225000,249999999,9/9/1919,9/9/2999,,0.8,,Table 6.8.1E page 72 -90.1-2016,0,224999,9/9/1919,9/9/2999,0.78,0.8,,Table 6.8.1E page 116 -90.1-2016,225000,249999999,9/9/1919,9/9/2999,,0.8,,Table 6.8.1E page 116 -90.1-2019,0,224999,9/9/1919,9/9/2999,,0.81,,Table 6.8.1-6 for > 225 ktbu/hr; Table F-4 for < 225 ktbu/hr -90.1-2019,225000,249999999,9/9/1919,9/9/2999,,0.8,,Table 6.8.1-6 for > 225 ktbu/hr; Table F-4 for < 225 ktbu/hr diff --git a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_heat_pump_cooling_90_1.csv b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_heat_pump_cooling_90_1.csv deleted file mode 100644 index 3ea90977be..0000000000 --- a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_heat_pump_cooling_90_1.csv +++ /dev/null @@ -1,165 +0,0 @@ -template,cooling_type,heating_type,subcategory,minimum_capacity,maximum_capacity,start_date,end_date,minimum_seasonal_efficiency,minimum_full_load_efficiency,minimum_iplv,minimum_integrated_energy_efficiency_ratio,pthp_eer_coefficient_1,pthp_eer_coefficient_2,cool_cap_ft,cool_cap_fflow,cool_eir_ft,cool_eir_fflow,cool_plf_fplr,annotation -90.1-2004,AirCooled,Electric Resistance or None,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,12.3,0.213,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1D -90.1-2004,AirCooled,All Other,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,12.3,0.213,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1D -90.1-2007,AirCooled,Electric Resistance or None,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,12.3,0.213,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2007 Table 6.8.1D -90.1-2007,AirCooled,All Other,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,12.3,0.213,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2007 Table 6.8.1D -90.1-2010,AirCooled,Electric Resistance or None,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,12.3,0.213,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1D Before 10/8/2012 -90.1-2010,AirCooled,All Other,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,12.3,0.213,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1D Before 10/8/2012 -90.1-2013,AirCooled,Electric Resistance or None,PTHP,0,9999999,9/9/1919,12/31/2015,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2013 Table 6.8.1-4 -90.1-2013,AirCooled,All Other,PTHP,0,9999999,9/9/1919,12/31/2015,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2013 Table 6.8.1-4 -90.1-2013,AirCooled,Electric Resistance or None,PTHP,0,9999999,1/1/2016,9/9/2999,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2013 Table 6.8.1-4 -90.1-2013,AirCooled,All Other,PTHP,0,9999999,1/1/2016,9/9/2999,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2013 Table 6.8.1-4 -90.1-2004,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,9.7,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2004,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,9.7,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2004,ThroughWall,Electric Resistance or None,Single Package,0,29999,9/9/1919,9/9/2999,9.7,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2004,ThroughWall,All Other,Single Package,0,29999,9/9/1919,9/9/2999,9.7,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2004,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B -90.1-2004,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,9.9,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B -90.1-2004,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,9.3,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B -90.1-2004,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,9.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B -90.1-2004,AirCooled,Electric Resistance or None,Single Package,240000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B -90.1-2004,AirCooled,All Other,Single Package,240000,9999999,9/9/1919,9/9/2999,,8.8,9,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B -90.1-2007,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" -90.1-2007,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" -90.1-2007,ThroughWall,Electric Resistance or None,Single Package,0,29999,9/9/1919,9/9/2999,10.6,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" -90.1-2007,ThroughWall,All Other,Single Package,0,29999,9/9/1919,9/9/2999,10.6,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" -90.1-2007,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" -90.1-2007,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,9.9,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" -90.1-2007,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,9.3,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" -90.1-2007,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,9.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" -90.1-2007,AirCooled,Electric Resistance or None,Single Package,240000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" -90.1-2007,AirCooled,All Other,Single Package,240000,9999999,9/9/1919,9/9/2999,,8.8,9,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" -90.1-2010,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,ThroughWall,Electric Resistance or None,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,ThroughWall,All Other,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,11,,11.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,10.8,,11,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,10.6,,10.7,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,10.4,,10.5,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,Electric Resistance or None,Single Package,240000,9999999,9/9/1919,9/9/2999,,9.5,,9.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,All Other,Single Package,240000,9999999,9/9/1919,9/9/2999,,9.3,,9.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2013,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,12/31/2014,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 -90.1-2013,AirCooled,All Other,Single Package,0,64999,9/9/1919,12/31/2014,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 -90.1-2013,AirCooled,Electric Resistance or None,Single Package,0,64999,1/1/2015,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 -90.1-2013,AirCooled,All Other,Single Package,0,64999,1/1/2015,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 -90.1-2013,ThroughWall,Electric Resistance or None,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 -90.1-2013,ThroughWall,All Other,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 -90.1-2013,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,12/31/2015,,11,,11.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,Electric Resistance or None,Single Package,65000,134999,1/1/2016,9/9/2999,,11,,12.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,All Other,Single Package,65000,134999,9/9/1919,12/31/2015,,10.8,,11,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,All Other,Single Package,65000,134999,1/1/2016,9/9/2999,,10.8,,12,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,12/31/2015,,10.6,,10.7,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,Electric Resistance or None,Single Package,135000,239999,1/1/2016,9/9/2999,,10.6,,11.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,All Other,Single Package,135000,239999,9/9/1919,12/31/2015,,10.4,,10.5,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,All Other,Single Package,135000,239999,1/1/2016,9/9/2999,,10.4,,11.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,Electric Resistance or None,Single Package,240000,9999999,9/9/1919,12/31/2015,,9.5,,9.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,Electric Resistance or None,Single Package,240000,9999999,1/1/2016,9/9/2999,,9.5,,10.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,All Other,Single Package,240000,9999999,9/9/1919,12/31/2015,,9.3,,9.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,All Other,Single Package,240000,9999999,1/1/2016,9/9/2999,,9.3,,0.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2004,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,10,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2004,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,10,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2004,ThroughWall,Electric Resistance or None,Split System,0,29999,9/9/1919,9/9/2999,10,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2004,ThroughWall,All Other,Split System,0,29999,9/9/1919,9/9/2999,10,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2004,SmallDuctHighVelocity,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,10,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B -90.1-2004,SmallDuctHighVelocity,All Other,Split System,0,64999,9/9/1919,9/9/2999,10,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B -90.1-2004,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B -90.1-2004,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,9.9,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B -90.1-2004,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,9.3,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B -90.1-2004,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,9.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B -90.1-2004,AirCooled,Electric Resistance or None,Split System,240000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B -90.1-2004,AirCooled,All Other,Split System,240000,9999999,9/9/1919,9/9/2999,,8.8,9,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B -90.1-2007,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" -90.1-2007,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" -90.1-2007,ThroughWall,Electric Resistance or None,Split System,0,29999,9/9/1919,9/9/2999,10.9,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" -90.1-2007,ThroughWall,All Other,Split System,0,29999,9/9/1919,9/9/2999,10.9,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" -90.1-2007,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" -90.1-2007,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,9.9,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" -90.1-2007,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,9.3,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" -90.1-2007,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,9.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" -90.1-2007,AirCooled,Electric Resistance or None,Split System,240000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" -90.1-2007,AirCooled,All Other,Split System,240000,9999999,9/9/1919,9/9/2999,,8.8,9,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" -90.1-2010,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,ThroughWall,Electric Resistance or None,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,ThroughWall,All Other,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,11,,11.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,10.8,,11,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,10.6,,10.7,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,10.4,,10.5,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,Electric Resistance or None,Split System,240000,9999999,9/9/1919,9/9/2999,,9.5,,9.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,All Other,Split System,240000,9999999,9/9/1919,9/9/2999,,9.3,,9.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2013,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,12/31/2014,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 -90.1-2013,AirCooled,All Other,Split System,0,64999,9/9/1919,12/31/2014,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 -90.1-2013,AirCooled,Electric Resistance or None,Split System,0,64999,1/1/2015,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 -90.1-2013,AirCooled,All Other,Split System,0,64999,1/1/2015,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 -90.1-2013,ThroughWall,Electric Resistance or None,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 -90.1-2013,ThroughWall,All Other,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 -90.1-2013,SmallDuctHighVelocity,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,11,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,SmallDuctHighVelocity,All Other,Split System,0,64999,9/9/1919,9/9/2999,11,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,12/31/2015,,11,,11.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,Electric Resistance or None,Split System,65000,134999,1/1/2016,9/9/2999,,11,,12.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,All Other,Split System,65000,134999,9/9/1919,12/31/2015,,10.8,,11,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,All Other,Split System,65000,134999,1/1/2016,9/9/2999,,10.8,,12,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,12/31/2015,,10.6,,10.7,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,Electric Resistance or None,Split System,135000,239999,1/1/2016,9/9/2999,,10.6,,11.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,All Other,Split System,135000,239999,9/9/1919,12/31/2015,,10.4,,10.5,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,All Other,Split System,135000,239999,1/1/2016,9/9/2999,,10.4,,11.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,Electric Resistance or None,Split System,240000,9999999,9/9/1919,12/31/2015,,9.5,,9.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,Electric Resistance or None,Split System,240000,9999999,1/1/2016,9/9/2999,,9.5,,10.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,All Other,Split System,240000,9999999,9/9/1919,12/31/2015,,9.3,,9.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,All Other,Split System,240000,9999999,1/1/2016,9/9/2999,,9.3,,0.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2016,AirCooled,Electric Resistance or None,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,All Other,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,ThroughWall,Electric Resistance or None,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,ThroughWall,All Other,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,11,,12.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,10.8,,12,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,10.6,,11.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,10.4,,11.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,Electric Resistance or None,Single Package,240000,9999999,9/9/1919,9/9/2999,,9.5,,10.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,All Other,Single Package,240000,9999999,9/9/1919,9/9/2999,,9.3,,0.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,ThroughWall,Electric Resistance or None,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,ThroughWall,All Other,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,SmallDuctHighVelocity,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,11,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,SmallDuctHighVelocity,All Other,Split System,0,64999,9/9/1919,9/9/2999,11,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,11,,12.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,10.8,,12,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,10.6,,11.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,10.4,,11.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,Electric Resistance or None,Split System,240000,9999999,9/9/1919,9/9/2999,,9.5,,10.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,All Other,Split System,240000,9999999,9/9/1919,9/9/2999,,9.3,,0.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,PTHP,0,6999,9/9/1919,9/9/2999,,11.9,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,PTHP,0,6999,9/9/1919,9/9/2999,,11.9,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,PTHP,7000,14999,1/1/2016,9/9/2999,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,PTHP,7000,14999,1/1/2016,9/9/2999,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,PTHP,15000,9999999,9/9/1919,9/9/2999,,9.5,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,PTHP,15000,9999999,9/9/1919,9/9/2999,,9.5,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,12/31/2014,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,Single Package,0,64999,9/9/1919,12/31/2014,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,ThroughWall,Electric Resistance or None,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,ThroughWall,All Other,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,11,,12.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,10.8,,12,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,10.6,,11.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,10.4,,11.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,Single Package,240000,9999999,9/9/1919,9/9/2999,,9.5,,10.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,Single Package,240000,9999999,9/9/1919,9/9/2999,,9.3,,0.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,ThroughWall,Electric Resistance or None,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,ThroughWall,All Other,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,SmallDuctHighVelocity,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,11,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,SmallDuctHighVelocity,All Other,Split System,0,64999,9/9/1919,9/9/2999,11,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,11,,12.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,10.8,,12,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,10.6,,11.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,10.4,,11.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,Split System,240000,9999999,9/9/1919,9/9/2999,,9.5,,10.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,Split System,240000,9999999,9/9/1919,9/9/2999,,9.3,,0.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, diff --git a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_heat_pump_heating_90_1.csv b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_heat_pump_heating_90_1.csv deleted file mode 100644 index b5fe02a2c7..0000000000 --- a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_heat_pump_heating_90_1.csv +++ /dev/null @@ -1,51 +0,0 @@ -template,cooling_type,subcategory,minimum_capacity,maximum_capacity,start_date,end_date,minimum_heating_seasonal_performance_factor,minimum_coefficient_of_performance_heating,minimum_energy_efficiency_ratio,pthp_cop_coefficient_1,pthp_cop_coefficient_2,heat_cap_ft,heat_cap_fflow,heat_eir_ft,heat_eir_fflow,heat_plf_fplr,annotation -90.1-2004,AirCooled,PTHP,0,9999999,9/9/1919,9/9/2999,,,,3.2,0.026,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2004 Table 6.8.1D -90.1-2007,AirCooled,PTHP,0,9999999,9/9/1919,9/9/2999,,,,3.2,0.026,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2007 Table 6.8.1D -90.1-2010,AirCooled,PTHP,0,9999999,9/9/1919,9/9/2999,,,,3.2,0.026,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2010 Table 6.8.1D before 10/08/2012 -90.1-2013,AirCooled,PTHP,0,9999999,9/9/1919,9/9/2999,,,,3.7,0.052,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2013 Table 6.8.1-4 -90.1-2004,AirCooled,Single Package,0,64999,9/9/1919,9/9/2999,6.6,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2004,ThroughWall,Single Package,0,29999,9/9/1919,9/9/2999,6.6,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2004,AirCooled,Single Package,65000,134999,9/9/1919,9/9/2999,,3.2,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2004,AirCooled,Single Package,135000,9999999,9/9/1919,9/9/2999,,3.1,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2007,AirCooled,Single Package,0,64999,9/9/1919,9/9/2999,7.7,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" -90.1-2007,ThroughWall,Single Package,0,29999,9/9/1919,9/9/2999,7,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" -90.1-2007,AirCooled,Single Package,65000,134999,9/9/1919,9/9/2999,,3.2,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" -90.1-2007,AirCooled,Single Package,135000,9999999,9/9/1919,9/9/2999,,3.1,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" -90.1-2010,AirCooled,Single Package,0,64999,9/9/1919,9/9/2999,7.7,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,ThroughWall,Single Package,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,Single Package,65000,134999,9/9/1919,9/9/2999,,3.3,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,Single Package,135000,9999999,9/9/1919,9/9/2999,,3.2,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2013,AirCooled,Single Package,0,64999,9/9/1919,12/31/2014,7.7,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2013 Table 6.8.1-2, Before 1/1/2015" -90.1-2013,AirCooled,Single Package,0,64999,1/1/2015,9/9/2999,8,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2013 Table 6.8.1-2, Before 1/1/2015" -90.1-2013,ThroughWall,Single Package,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2013 Table 6.8.1-3 -90.1-2013,AirCooled,Single Package,65000,134999,9/9/1919,9/9/2999,,3.3,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR,From 90.1-2013 Table 6.8.1-5 -90.1-2013,AirCooled,Single Package,135000,9999999,9/9/1919,9/9/2999,,3.2,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR,From 90.1-2013 Table 6.8.1-6 -90.1-2004,AirCooled,Split System,0,64999,9/9/1919,9/9/2999,6.8,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2004,ThroughWall,Split System,0,29999,9/9/1919,9/9/2999,6.8,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2004,SmallDuctHighVelocity,Split System,0,64999,9/9/1919,9/9/2999,6.8,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2007,AirCooled,Split System,0,64999,9/9/1919,9/9/2999,7.7,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" -90.1-2007,ThroughWall,Split System,0,29999,9/9/1919,9/9/2999,7.1,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" -90.1-2010,AirCooled,Split System,0,64999,9/9/1919,9/9/2999,7.7,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,ThroughWall,Split System,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2013,AirCooled,Split System,0,64999,9/9/1919,12/31/2014,7.7,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2013 Table 6.8.1-2, Before 1/1/2015" -90.1-2013,AirCooled,Split System,0,64999,1/1/2015,9/9/2999,8.2,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2013 Table 6.8.1-2, Before 1/1/2015" -90.1-2013,ThroughWall,Split System,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2013 Table 6.8.1-2 -90.1-2013,SmallDuctHighVelocity,Split System,0,64999,9/9/1919,9/9/2999,6.8,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2013 Table 6.8.1-4 -90.1-2016,AirCooled,PTHP,0,9999999,9/9/1919,9/9/2999,,,,3.7,0.052,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, -90.1-2016,AirCooled,Single Package,0,64999,9/9/1919,9/9/2999,8,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,ThroughWall,Single Package,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, -90.1-2016,AirCooled,Single Package,65000,134999,9/9/1919,9/9/2999,,3.3,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,Single Package,135000,9999999,9/9/1919,9/9/2999,,3.2,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,Split System,0,64999,9/9/1919,9/9/2999,8.2,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,ThroughWall,Split System,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, -90.1-2016,SmallDuctHighVelocity,Split System,0,64999,9/9/1919,9/9/2999,6.8,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, -90.1-2019,AirCooled,PTHP,0,6999,9/9/1919,9/9/2999,,3.3,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, -90.1-2019,AirCooled,PTHP,6999,14999,9/9/1919,9/9/2999,,,,3.7,0.052,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, -90.1-2019,AirCooled,PTHP,14999,9999999,9/9/1919,9/9/2999,,2.9,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, -90.1-2019,AirCooled,Single Package,0,64999,9/9/1919,9/9/2999,8,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,ThroughWall,Single Package,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, -90.1-2019,AirCooled,Single Package,65000,134999,9/9/1919,9/9/2999,,3.3,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Single Package,135000,9999999,9/9/1919,9/9/2999,,3.2,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Split System,0,64999,9/9/1919,9/9/2999,8.2,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,ThroughWall,Split System,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, -90.1-2019,SmallDuctHighVelocity,Split System,0,64999,9/9/1919,9/9/2999,6.8,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, diff --git a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_heat_rejection_90_1.csv b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_heat_rejection_90_1.csv deleted file mode 100644 index 886007d819..0000000000 --- a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_heat_rejection_90_1.csv +++ /dev/null @@ -1,31 +0,0 @@ -template,equipment_type,fan_type,start_date,end_date,minimum_performance_gpm_per_hp,annotation -90.1-2004,Open Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2004 Table 6.8.1G -90.1-2004,Open Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,38.2,From 90.1-2004 Table 6.8.1G -90.1-2004,Closed Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2004 Table 6.8.1G -90.1-2004,Closed Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,38.2,From 90.1-2004 Table 6.8.1G -90.1-2004,Dry Cooler,Propeller or Axial,9/9/1919,9/9/2999,4,Not required by code. Value provided by 90.1 Mechanical Subcommittee -90.1-2007,Open Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2007 Table 6.8.1G -90.1-2007,Open Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,38.2,From 90.1-2007 Table 6.8.1G -90.1-2007,Closed Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2007 Table 6.8.1G -90.1-2007,Closed Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,38.2,From 90.1-2007 Table 6.8.1G -90.1-2007,Dry Cooler,Propeller or Axial,9/9/1919,9/9/2999,4,Not required by code. Value provided by 90.1 Mechanical Subcommittee -90.1-2010,Open Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2010 Table 6.8.1 G -90.1-2010,Open Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,38.2,From 90.1-2010 Table 6.8.1 G -90.1-2010,Closed Cooling Tower,Centrifugal,9/9/1919,9/9/2999,7,From 90.1-2010 Table 6.8.1 G -90.1-2010,Closed Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,14,From 90.1-2010 Table 6.8.1 G -90.1-2010,Dry Cooler,Propeller or Axial,9/9/1919,9/9/2999,4,Not required by code. Value provided by 90.1 Mechanical Subcommittee -90.1-2013,Open Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2013 Table 6.8.1-7 -90.1-2013,Open Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,40.2,From 90.1-2013 Table 6.8.1-7 -90.1-2013,Closed Cooling Tower,Centrifugal,9/9/1919,9/9/2999,7,From 90.1-2013 Table 6.8.1-7 -90.1-2013,Closed Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,14,From 90.1-2013 Table 6.8.1-7 -90.1-2013,Dry Cooler,Propeller or Axial,9/9/1919,9/9/2999,4,NOTE: Not required by code. Value provided by 90.1 Mechanical Subcommittee -90.1-2016,Open Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2016 Table 6.8.1-7 -90.1-2016,Open Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,40.2,From 90.1-2016 Table 6.8.1-7 -90.1-2016,Closed Cooling Tower,Centrifugal,9/9/1919,9/9/2999,7,From 90.1-2016 Table 6.8.1-7 -90.1-2016,Closed Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,16.1,From 90.1-2016 Table 6.8.1-7 -90.1-2016,Dry Cooler,Propeller or Axial,9/9/1919,9/9/2999,4,NOTE Not required by code. Value provided by 90.1 Mechanical Subcommittee -90.1-2019,Open Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2019 Table 6.8.1-7 -90.1-2019,Open Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,40.2,From 90.1-2019 Table 6.8.1-7 -90.1-2019,Closed Cooling Tower,Centrifugal,9/9/1919,9/9/2999,7,From 90.1-2019 Table 6.8.1-7 -90.1-2019,Closed Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,16.1,From 90.1-2019 Table 6.8.1-7 -90.1-2019,Dry Cooler,Propeller or Axial,9/9/1919,9/9/2999,4.5,From 90.1-2019 Table 6.8.1.7. Juan Gonzalez Added 01/11/2021 to account for fluid coolers in data center water loop heat pump condenser loops diff --git a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_motors_90_1.csv b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_motors_90_1.csv deleted file mode 100644 index 986abcdab9..0000000000 --- a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_motors_90_1.csv +++ /dev/null @@ -1,148 +0,0 @@ -template,number_of_poles,type,synchronous_speed,minimum_capacity,maximum_capacity,nominal_full_load_efficiency,annotation -90.1-2004,4,Enclosed,1800,0,0.999,0.29,"Motors below 1 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" -90.1-2004,4,Enclosed,1800,1,1.499,0.825,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,1.5,1.999,0.84,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,2,2.999,0.84,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,3,4.999,0.875,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,5,7.499,0.875,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,7.5,9.999,0.895,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,10,14.999,0.895,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,15,19.999,0.91,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,20,24.999,0.91,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,25,29.999,0.924,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,30,39.999,0.924,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,40,49.999,0.93,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,50,59.999,0.93,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,60,74.999,0.936,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,75,99.999,0.941,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,100,124.999,0.945,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,125,149.999,0.945,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,150,199.999,0.95,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,200,9999,0.95,From 90.1-2004 Table 10.8 -90.1-2007,4,Enclosed,1800,0,0.999,0.29,"Motors below 1 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" -90.1-2007,4,Enclosed,1800,1,1.499,0.825,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,1.5,1.999,0.84,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,2,2.999,0.84,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,3,4.999,0.875,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,5,7.499,0.875,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,7.5,9.999,0.895,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,10,14.999,0.895,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,15,19.999,0.91,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,20,24.999,0.91,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,25,29.999,0.924,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,30,39.999,0.924,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,40,49.999,0.93,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,50,59.999,0.93,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,60,74.999,0.936,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,75,99.999,0.941,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,100,124.999,0.945,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,125,149.999,0.945,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,150,199.999,0.95,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,200,9999,0.95,From 90.1-2007 Table 10.8 -90.1-2010,4,Enclosed,1800,0,0.999,0.29,"Motors below 1 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" -90.1-2010,4,Enclosed,1800,1,1.499,0.855,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,1.5,1.999,0.865,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,2,2.999,0.865,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,3,4.999,0.895,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,5,7.499,0.895,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,7.5,9.999,0.917,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,10,14.999,0.917,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,15,19.999,0.924,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,20,24.9999,0.93,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,25,29.999,0.936,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,30,39.999,0.936,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,40,49.999,0.941,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,50,59.999,0.945,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,60,74.999,0.95,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,75,99.999,0.954,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,100,124.999,0.954,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,125,149.999,0.954,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,150,199.999,0.958,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,200,249.999,0.962,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,250,299.999,0.962,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,300,349.999,0.962,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,350,399.999,0.962,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,400,449.999,0.962,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,450,499.999,0.962,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,500,9999,0.962,From 90.1-2010 Table 10.8B -90.1-2013,4,Enclosed,1800,0,0.08333,0.29,"Motors below 1/12 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" -90.1-2013,4,Enclosed,1800,0.08334,0.999,0.7,"Motors between 1/12 and 1 HP must be EC, with minimum efficiency of 70% per PNNL" -90.1-2013,4,Enclosed,1800,1,1.499,0.855, -90.1-2013,4,Enclosed,1800,1.5,1.999,0.865, -90.1-2013,4,Enclosed,1800,2,2.999,0.865, -90.1-2013,4,Enclosed,1800,3,4.999,0.895, -90.1-2013,4,Enclosed,1800,5,7.499,0.895, -90.1-2013,4,Enclosed,1800,7.5,9.999,0.917, -90.1-2013,4,Enclosed,1800,10,14.999,0.917, -90.1-2013,4,Enclosed,1800,15,19.999,0.924, -90.1-2013,4,Enclosed,1800,20,24.999,0.93, -90.1-2013,4,Enclosed,1800,25,29.999,0.936, -90.1-2013,4,Enclosed,1800,30,39.999,0.936, -90.1-2013,4,Enclosed,1800,40,49.999,0.941, -90.1-2013,4,Enclosed,1800,50,59.999,0.945, -90.1-2013,4,Enclosed,1800,60,74.999,0.95, -90.1-2013,4,Enclosed,1800,75,99.999,0.954, -90.1-2013,4,Enclosed,1800,100,124.999,0.954, -90.1-2013,4,Enclosed,1800,125,149.999,0.954, -90.1-2013,4,Enclosed,1800,150,199.999,0.958, -90.1-2013,4,Enclosed,1800,200,249.999,0.962, -90.1-2013,4,Enclosed,1800,250,299.999,0.95, -90.1-2013,4,Enclosed,1800,300,349.999,0.954, -90.1-2013,4,Enclosed,1800,350,399.999,0.954, -90.1-2013,4,Enclosed,1800,400,449.999,0.954, -90.1-2013,4,Enclosed,1800,450,499.999,0.954, -90.1-2013,4,Enclosed,1800,500,9999,0.954, -90.1-2016,4,Enclosed,1800,0,0.08333,0.29,"Motors below 1/12 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" -90.1-2016,4,Enclosed,1800,0.08334,0.999,0.7,"Motors between 1/12 and 1 HP must be EC, with minimum efficiency of 70% per PNNL" -90.1-2016,4,Enclosed,1800,1,1.499,0.855, -90.1-2016,4,Enclosed,1800,1.5,1.999,0.865, -90.1-2016,4,Enclosed,1800,2,2.999,0.865, -90.1-2016,4,Enclosed,1800,3,4.999,0.895, -90.1-2016,4,Enclosed,1800,5,7.499,0.895, -90.1-2016,4,Enclosed,1800,7.5,9.999,0.917, -90.1-2016,4,Enclosed,1800,10,14.999,0.917, -90.1-2016,4,Enclosed,1800,15,19.999,0.924, -90.1-2016,4,Enclosed,1800,20,24.999,0.93, -90.1-2016,4,Enclosed,1800,25,29.999,0.936, -90.1-2016,4,Enclosed,1800,30,39.999,0.936, -90.1-2016,4,Enclosed,1800,40,49.999,0.941, -90.1-2016,4,Enclosed,1800,50,59.999,0.945, -90.1-2016,4,Enclosed,1800,60,74.999,0.95, -90.1-2016,4,Enclosed,1800,75,99.999,0.954, -90.1-2016,4,Enclosed,1800,100,124.999,0.954, -90.1-2016,4,Enclosed,1800,125,149.999,0.954, -90.1-2016,4,Enclosed,1800,150,199.999,0.958, -90.1-2016,4,Enclosed,1800,200,249.999,0.962, -90.1-2016,4,Enclosed,1800,250,299.999,0.962, -90.1-2016,4,Enclosed,1800,300,349.999,0.962, -90.1-2016,4,Enclosed,1800,350,399.999,0.962, -90.1-2016,4,Enclosed,1800,400,449.999,0.962, -90.1-2016,4,Enclosed,1800,450,499.999,0.962, -90.1-2016,4,Enclosed,1800,500,9999,0.962, -90.1-2019,4,Enclosed,1800,0,0.08333,0.29,"Motors below 1/12 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" -90.1-2019,4,Enclosed,1800,0.08334,0.999,0.7,"Motors between 1/12 and 1 HP must be EC, with minimum efficiency of 70% per PNNL" -90.1-2019,4,Enclosed,1800,1,1.499,0.855, -90.1-2019,4,Enclosed,1800,1.5,1.999,0.865, -90.1-2019,4,Enclosed,1800,2,2.999,0.865, -90.1-2019,4,Enclosed,1800,3,4.999,0.895, -90.1-2019,4,Enclosed,1800,5,7.499,0.895, -90.1-2019,4,Enclosed,1800,7.5,9.999,0.917, -90.1-2019,4,Enclosed,1800,10,14.999,0.917, -90.1-2019,4,Enclosed,1800,15,19.999,0.924, -90.1-2019,4,Enclosed,1800,20,24.999,0.93, -90.1-2019,4,Enclosed,1800,25,29.999,0.936, -90.1-2019,4,Enclosed,1800,30,39.999,0.936, -90.1-2019,4,Enclosed,1800,40,49.999,0.941, -90.1-2019,4,Enclosed,1800,50,59.999,0.945, -90.1-2019,4,Enclosed,1800,60,74.999,0.95, -90.1-2019,4,Enclosed,1800,75,99.999,0.954, -90.1-2019,4,Enclosed,1800,100,124.999,0.954, -90.1-2019,4,Enclosed,1800,125,149.999,0.954, -90.1-2019,4,Enclosed,1800,150,199.999,0.958, -90.1-2019,4,Enclosed,1800,200,249.999,0.962, -90.1-2019,4,Enclosed,1800,250,299.999,0.962, -90.1-2019,4,Enclosed,1800,300,349.999,0.962, -90.1-2019,4,Enclosed,1800,350,399.999,0.962, -90.1-2019,4,Enclosed,1800,400,449.999,0.962, -90.1-2019,4,Enclosed,1800,450,499.999,0.962, -90.1-2019,4,Enclosed,1800,500,9999,0.962, diff --git a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_unitary_air_conditioners_90_1.csv b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_unitary_air_conditioners_90_1.csv deleted file mode 100644 index 51d10b80ba..0000000000 --- a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_unitary_air_conditioners_90_1.csv +++ /dev/null @@ -1,196 +0,0 @@ -template,cooling_type,heating_type,subcategory,minimum_capacity,maximum_capacity,start_date,end_date,minimum_seasonal_efficiency,minimum_energy_efficiency_ratio,minimum_integrated_part_load_value,minimum_integrated_energy_efficiency_ratio,ptac_eer_coefficient_1,ptac_eer_coefficient_2,minimum_scop,cool_cap_ft,cool_cap_fflow,cool_eir_ft,cool_eir_fflow,cool_plf_fplr,annotation -90.1-2004,AirCooled,All Other,PTAC,0,9999999,9/9/1919,9/9/2999,,,,,12.5,0.213,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2004,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,9.7,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,9.5,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,All Other,Single Package,240000,759999,9/9/1919,9/9/2999,,9.3,9.5,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,All Other,Single Package,760000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,10,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,9.5,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,All Other,Split System,240000,759999,9/9/1919,9/9/2999,,9.3,9.5,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,All Other,Split System,760000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,Electric Resistance or None,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.2,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2004 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" -90.1-2004,AirCooled,Electric Resistance or None,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.1,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2004 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" -90.1-2004,AirCooled,Electric Resistance or None,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,1.9,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2004 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" -90.1-2004,AirCooled,Electric Resistance or None,PTAC,0,9999999,9/9/1919,9/9/2999,,,,,12.5,0.213,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2004,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,9.7,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,10.3,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,9.7,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,Electric Resistance or None,Single Package,240000,759999,9/9/1919,9/9/2999,,9.5,9.7,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,Electric Resistance or None,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.2,9.4,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,10,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,10.3,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,9.7,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,Electric Resistance or None,Split System,240000,759999,9/9/1919,9/9/2999,,9.5,9.7,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,Electric Resistance or None,Split System,760000,9999999,9/9/1919,9/9/2999,,9.2,9.4,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,WaterCooled,All Other,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.6,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2004 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" -90.1-2004,WaterCooled,All Other,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.5,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2004 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" -90.1-2004,WaterCooled,All Other,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,2.4,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2004 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" -90.1-2007,AirCooled,All Other,PTAC,0,9999999,9/9/1919,9/9/2999,,,,,12.5,0.213,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2007,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,9.5,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,All Other,Single Package,240000,759999,9/9/1919,9/9/2999,,9.3,9.5,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,All Other,Single Package,760000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,9.5,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,All Other,Split System,240000,759999,9/9/1919,9/9/2999,,9.3,9.5,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,All Other,Split System,760000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,Electric Resistance or None,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.2,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2007 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" -90.1-2007,AirCooled,Electric Resistance or None,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.1,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2007 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" -90.1-2007,AirCooled,Electric Resistance or None,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,1.9,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2007 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" -90.1-2007,AirCooled,Electric Resistance or None,PTAC,0,9999999,9/9/1919,9/9/2999,,,,,12.5,0.213,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2007,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,10.3,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,9.7,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,Electric Resistance or None,Single Package,240000,759999,9/9/1919,9/9/2999,,9.5,9.7,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,Electric Resistance or None,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.2,9.4,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,10.3,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,9.7,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,Electric Resistance or None,Split System,240000,759999,9/9/1919,9/9/2999,,9.5,9.7,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,Electric Resistance or None,Split System,760000,9999999,9/9/1919,9/9/2999,,9.2,9.4,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,WaterCooled,All Other,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.6,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2007 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" -90.1-2007,WaterCooled,All Other,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.5,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2007 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" -90.1-2007,WaterCooled,All Other,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,2.4,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2007 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" -90.1-2010,AirCooled,All Other,PTAC,0,9999999,9/9/1919,9/9/2999,,,,,13.8,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2010,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2010,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,11,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2010,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,10.8,,,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, -90.1-2010,AirCooled,All Other,Single Package,240000,759999,9/9/1919,9/9/2999,,9.8,,9.7,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, -90.1-2010,AirCooled,All Other,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.5,,9.2,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, -90.1-2010,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2010,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,11,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2010,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,10.8,,,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, -90.1-2010,AirCooled,All Other,Split System,240000,759999,9/9/1919,9/9/2999,,9.8,,9.7,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, -90.1-2010,AirCooled,All Other,Split System,760000,9999999,9/9/1919,9/9/2999,,9.5,,9.2,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, -90.1-2010,AirCooled,Electric Resistance or None,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.2,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for downflow units -90.1-2010,AirCooled,Electric Resistance or None,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.1,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for downflow units -90.1-2010,AirCooled,Electric Resistance or None,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,1.9,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for downflow units -90.1-2010,AirCooled,Electric Resistance or None,PTAC,0,9999999,9/9/1919,9/9/2999,,,,,13.8,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2010,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2010,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,11.2,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2010,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,11,,,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, -90.1-2010,AirCooled,Electric Resistance or None,Single Package,240000,759999,9/9/1919,9/9/2999,,10,,9.7,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, -90.1-2010,AirCooled,Electric Resistance or None,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.7,,9.4,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, -90.1-2010,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2010,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,11.2,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2010,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,11,,,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, -90.1-2010,AirCooled,Electric Resistance or None,Split System,240000,759999,9/9/1919,9/9/2999,,10,,9.7,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, -90.1-2010,AirCooled,Electric Resistance or None,Split System,760000,9999999,9/9/1919,9/9/2999,,9.7,,9.4,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, -90.1-2010,WaterCooled,All Other,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.6,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units -90.1-2010,WaterCooled,All Other,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.5,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units -90.1-2010,WaterCooled,All Other,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,2.4,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units -90.1-2013,AirCooled,All Other,PTAC,0,9999999,9/9/1919,12/31/2014,,,,,13.8,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2013,AirCooled,All Other,PTAC,0,9999999,1/1/2015,9/9/2999,,,,,14,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2013,AirCooled,All Other,Single Package,0,64999,9/9/1919,12/31/2014,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Single Package,0,64999,1/1/2015,9/9/2999,14,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Single Package,65000,134999,9/9/1919,12/31/2015,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Single Package,135000,239999,9/9/1919,12/31/2015,,10.8,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Single Package,240000,759999,9/9/1919,12/31/2015,,9.8,,9.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Single Package,760000,9999999,9/9/1919,12/31/2015,,9.5,,9.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Single Package,65000,134999,1/1/2016,9/9/2999,,11,,12.7,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Single Package,135000,239999,1/1/2016,9/9/2999,,10.8,,12.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Single Package,240000,759999,1/1/2016,9/9/2999,,9.8,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Single Package,760000,9999999,1/1/2016,9/9/2999,,9.5,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Split System,65000,134999,9/9/1919,12/31/2015,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Split System,135000,239999,9/9/1919,12/31/2015,,10.8,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Split System,240000,759999,9/9/1919,12/31/2015,,9.8,,9.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Split System,760000,9999999,9/9/1919,12/31/2015,,9.5,,9.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Split System,65000,134999,1/1/2016,9/9/2999,,11,,12.7,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Split System,135000,239999,1/1/2016,9/9/2999,,10.8,,12.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Split System,240000,759999,1/1/2016,9/9/2999,,9.8,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Split System,760000,9999999,1/1/2016,9/9/2999,,9.5,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.2,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units -90.1-2013,AirCooled,Electric Resistance or None,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.1,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units -90.1-2013,AirCooled,Electric Resistance or None,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,1.9,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units -90.1-2013,AirCooled,Electric Resistance or None,PTAC,0,9999999,9/9/1919,12/31/2014,,,,,13.8,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2013,AirCooled,Electric Resistance or None,PTAC,0,9999999,1/1/2015,9/9/2999,,,,,14,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2013,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,12/31/2014,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Single Package,0,64999,1/1/2015,9/9/2999,14,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,12/31/2015,,11.2,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,12/31/2015,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Single Package,240000,759999,9/9/1919,12/31/2015,,10,,10.1,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Single Package,760000,9999999,9/9/1919,12/31/2015,,9.7,,9.8,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Single Package,65000,134999,1/1/2016,9/9/2999,,11.2,,12.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Single Package,135000,239999,1/1/2016,9/9/2999,,11,,12.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Single Package,240000,759999,1/1/2016,9/9/2999,,10,,11.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Single Package,760000,9999999,1/1/2016,9/9/2999,,9.7,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,12/31/2015,,11.2,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,12/31/2015,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Split System,240000,759999,9/9/1919,12/31/2015,,10,,10.1,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Split System,760000,9999999,9/9/1919,12/31/2015,,9.7,,9.8,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Split System,65000,134999,1/1/2016,9/9/2999,,11.2,,12.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Split System,135000,239999,1/1/2016,9/9/2999,,11,,12.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Split System,240000,759999,1/1/2016,9/9/2999,,10,,11.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Split System,760000,9999999,1/1/2016,9/9/2999,,9.7,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,WaterCooled,All Other,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.6,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units -90.1-2013,WaterCooled,All Other,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.5,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units -90.1-2013,WaterCooled,All Other,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,2.4,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units -90.1-2016,AirCooled,All Other,PTAC,0,9999999,9/9/1919,12/31/2014,,,,,13.8,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,All Other,PTAC,0,9999999,1/1/2015,9/9/2999,,,,,14,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,14,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,10.8,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,All Other,Single Package,240000,759999,9/9/1919,9/9/2999,,9.8,,9.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,All Other,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.5,,9.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,10.8,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,All Other,Split System,240000,759999,9/9/1919,9/9/2999,,9.8,,9.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,All Other,Split System,760000,9999999,9/9/1919,9/9/2999,,9.5,,9.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,Electric Resistance or None,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.3,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units -90.1-2016,AirCooled,Electric Resistance or None,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.2,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units -90.1-2016,AirCooled,Electric Resistance or None,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,2,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units -90.1-2016,AirCooled,Electric Resistance or None,PTAC,0,9999999,9/9/1919,12/31/2014,,,,,13.8,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,Electric Resistance or None,PTAC,0,9999999,1/1/2015,9/9/2999,,,,,14,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,12/31/2014,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,Electric Resistance or None,Single Package,0,64999,1/1/2015,9/9/2999,14,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,11.2,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,Electric Resistance or None,Single Package,240000,759999,9/9/1919,9/9/2999,,10,,10.1,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,Electric Resistance or None,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.7,,9.8,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,11.2,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,Electric Resistance or None,Split System,240000,759999,9/9/1919,9/9/2999,,10,,10.1,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,Electric Resistance or None,Split System,760000,9999999,9/9/1919,9/9/2999,,9.7,,9.8,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,WaterCooled,All Other,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.5,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units -90.1-2016,WaterCooled,All Other,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.4,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units -90.1-2016,WaterCooled,All Other,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,2.25,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units -90.1-2019,AirCooled,All Other,PTAC,0,6999,9/9/1919,9/9/2999,,11.9,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,PTAC,6999,14999,9/9/1919,9/9/2999,,,,,14,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,PTAC,14999,9999999,9/9/1919,9/9/2999,,9.5,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,14,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,11,,12.7,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,10.8,,12.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,All Other,Single Package,240000,759999,9/9/1919,9/9/2999,,9.8,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,All Other,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.5,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,11,,12.7,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,10.8,,12.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,All Other,Split System,240000,759999,9/9/1919,9/9/2999,,9.8,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,All Other,Split System,760000,9999999,9/9/1919,9/9/2999,,9.5,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,Electric Resistance or None,CRAC,0,79999,9/9/1919,9/9/2999,,,,,,,2.7,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for downflow units -90.1-2019,AirCooled,Electric Resistance or None,CRAC,80000,294999,9/9/1919,9/9/2999,,,,,,,2.58,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for downflow units -90.1-2019,AirCooled,Electric Resistance or None,CRAC,295000,9999999,9/9/1919,9/9/2999,,,,,,,2.36,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for downflow units -90.1-2019,AirCooled,Electric Resistance or None,PTAC,0,6999,9/9/1919,9/9/2999,,11.9,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,PTAC,6999,14999,9/9/1919,9/9/2999,,,,,14,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,PTAC,14999,9999999,9/9/1919,9/9/2999,,9.5,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,14,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,11.2,,12.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,11,,12.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,Electric Resistance or None,Single Package,240000,759999,9/9/1919,9/9/2999,,10,,11.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,Electric Resistance or None,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.7,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,11.2,,12.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,11,,12.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,Electric Resistance or None,Split System,240000,759999,9/9/1919,9/9/2999,,10,,11.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,Electric Resistance or None,Split System,760000,9999999,9/9/1919,9/9/2999,,9.7,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,WaterCooled,All Other,CRAC,0,79999,9/9/1919,9/9/2999,,,,,,,2.82,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for water cooled downflow units -90.1-2019,WaterCooled,All Other,CRAC,80000,294999,9/9/1919,9/9/2999,,,,,,,2.73,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for water cooled downflow units -90.1-2019,WaterCooled,All Other,CRAC,295000,9999999,9/9/1919,9/9/2999,,,,,,,2.67,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for water cooled downflow units diff --git a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_water_heaters_90_1.csv b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_water_heaters_90_1.csv deleted file mode 100644 index 67ef79f434..0000000000 --- a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_water_heaters_90_1.csv +++ /dev/null @@ -1,25 +0,0 @@ -template,fuel_type,minimum_capacity,maximum_capacity,start_date,end_date,energy_factor_base,energy_factor_volume_derate,standby_loss_base,standby_loss_capacity_allowance,standby_loss_volume_allowance,hourly_loss_base,hourly_loss_volume_allowance,thermal_efficiency,annotation -90.1-2004,Electricity,0,40945.99,9/9/1919,9/9/2999,0.93,0.00132,,,,,,,From 90.1-2004 Table 7.8 -90.1-2004,Electricity,40946,99999999,9/9/1919,9/9/2999,,,20,,35,,,,From 90.1-2004 Table 7.8 -90.1-2004,NaturalGas,0,74999.99,9/9/1919,9/9/2999,0.62,0.0019,,,,,,,From 90.1-2004 Table 7.8 -90.1-2004,NaturalGas,75000,99999999,9/9/1919,9/9/2999,,,,800,110,,,0.8,From 90.1-2004 Table 7.8 -90.1-2007,Electricity,0,40945.99,9/9/1919,9/9/2999,0.93,0.00132,,,,,,,From 90.1-2007 Table 7.8 -90.1-2007,Electricity,40946,99999999,9/9/1919,9/9/2999,,,20,,35,,,,From 90.1-2007 Table 7.8 -90.1-2007,NaturalGas,0,74999.99,9/9/1919,9/9/2999,0.62,0.0019,,,,,,,From 90.1-2007 Table 7.8 -90.1-2007,NaturalGas,75000,99999999,9/9/1919,9/9/2999,,,,800,110,,,0.8,From 90.1-2007 Table 7.8 -90.1-2010,Electricity,0,40945.99,9/9/1919,9/9/2999,0.97,0.00132,,,,,,,From 90.1-2010 Table 7.8 -90.1-2010,Electricity,40946,99999999,9/9/1919,9/9/2999,,,20,,35,,,,From 90.1-2010 Table 7.8 -90.1-2010,NaturalGas,0,74999.99,9/9/1919,9/9/2999,0.67,0.0019,,,,,,,From 90.1-2010 Table 7.8 -90.1-2010,NaturalGas,75000,99999999,9/9/1919,9/9/2999,,,,800,110,,,0.8,From 90.1-2010 Table 7.8 -90.1-2013,Electricity,0,40945.99,9/9/1919,9/9/2999,0.97,0.00132,,,,,,,From 90.1-2013 Table 7.8 -90.1-2013,Electricity,40946,99999999,9/9/1919,9/9/2999,,,,,,0.3,27,,From 90.1-2013 Table 7.8 -90.1-2013,NaturalGas,0,74999.99,9/9/1919,9/9/2999,0.67,0.0019,,,,,,,From 90.1-2013 Table 7.8 -90.1-2013,NaturalGas,75000,99999999,9/9/1919,9/9/2999,,,,800,110,,,0.8,From 90.1-2013 Table 7.8 -90.1-2016,Electricity,0,40945.99,9/9/1919,9/9/2999,0.96,0.0003,,,,,,,"From 90.1-2016 Table F-2, Rated Storage Volume <= 55 gal" -90.1-2016,Electricity,40946,99999999,9/9/1919,9/9/2999,,,,,,0.3,27,, -90.1-2016,NaturalGas,0,74999.99,9/9/1919,9/9/2999,0.675,0.0015,,,,,,,"From 90.1-2016 Table F-2, Rated Storage Volume <= 55 gal" -90.1-2016,NaturalGas,75000,99999999,9/9/1919,9/9/2999,,,,800,110,,,0.8, -90.1-2019,Electricity,0,40945.99,9/9/1919,9/9/2999,0.96,0.0003,,,,,,,Same as 90.1-2016 as placeholder; 90.1-2019 Table F-2 uses UEF -90.1-2019,Electricity,40946,99999999,9/9/1919,9/9/2999,,,,,,0.3,27,, -90.1-2019,NaturalGas,0,74999.99,9/9/1919,9/9/2999,0.675,0.0015,,,,,,,Same as 90.1-2016 as placeholder; 90.1-2019 Table F-2 uses UEF -90.1-2019,NaturalGas,75000,99999999,9/9/1919,9/9/2999,,,,800,110,,,0.8, diff --git a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1.csv b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1.csv deleted file mode 100644 index 3ef18bfab7..0000000000 --- a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1.csv +++ /dev/null @@ -1,19 +0,0 @@ -template,minimum_capacity,maximum_capacity,start_date,end_date,minimum_full_load_efficiency,annotation -90.1-2004,0,16999,9/9/1919,9/9/2999,11.2,From 90.1-2004 Table 6.8.1B -90.1-2004,17000,64999,9/9/1919,9/9/2999,12,From 90.1-2004 Table 6.8.1B -90.1-2004,65000,134999,9/9/1919,9/9/2999,12,From 90.1-2004 Table 6.8.1B -90.1-2007,0,16999,9/9/1919,9/9/2999,11.2,From 90.1-2007 Table 6.8.1B -90.1-2007,17000,64999,9/9/1919,9/9/2999,12,From 90.1-2007 Table 6.8.1B -90.1-2007,65000,134999,9/9/1919,9/9/2999,12,From 90.1-2007 Table 6.8.1B -90.1-2010,0,16999,9/9/1919,9/9/2999,11.2,From 90.1-2010 Table 6.8.1B -90.1-2010,17000,64999,9/9/1919,9/9/2999,12,From 90.1-2010 Table 6.8.1B -90.1-2010,65000,134999,9/9/1919,9/9/2999,12,From 90.1-2010 Table 6.8.1B -90.1-2013,0,16999,9/9/1919,9/9/2999,12.2,From 90.1-2013 Table 6.8.1-2 -90.1-2013,17000,64999,9/9/1919,9/9/2999,13,From 90.1-2013 Table 6.8.1-2 -90.1-2013,65000,134999,9/9/1919,9/9/2999,13,From 90.1-2013 Table 6.8.1-2 -90.1-2016,0,16999,9/9/1919,9/9/2999,12.2, -90.1-2016,17000,64999,9/9/1919,9/9/2999,13, -90.1-2016,65000,134999,9/9/1919,9/9/2999,13, -90.1-2019,0,16999,9/9/1919,9/9/2999,12.2, -90.1-2019,17000,64999,9/9/1919,9/9/2999,13, -90.1-2019,65000,134999,9/9/1919,9/9/2999,13, diff --git a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_water_source_heat_pumps_heating_90_1.csv b/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_water_source_heat_pumps_heating_90_1.csv deleted file mode 100644 index 2359b75f6d..0000000000 --- a/data/openstudio_standards_data/initial_data/hvac_minimum_requirement_water_source_heat_pumps_heating_90_1.csv +++ /dev/null @@ -1,7 +0,0 @@ -template,minimum_capacity,maximum_capacity,start_date,end_date,minimum_coefficient_of_performance,annotation -90.1-2004,0,9999999,9/9/1919,9/9/2999,4.2,From 90.1-2004 Table 6.8.1B -90.1-2007,0,9999999,9/9/1919,9/9/2999,4.2,From 90.1-2007 Table 6.8.1B -90.1-2010,0,9999999,9/9/1919,9/9/2999,4.2,From 90.1-2010 Table 6.8.1B -90.1-2013,0,9999999,9/9/1919,9/9/2999,4.3,From 90.1-2013 Table 6.8.1-2 -90.1-2016,0,9999999,9/9/1919,9/9/2999,4.3,From 90.1-2016 Table 6.8.1-2 -90.1-2019,0,9999999,9/9/1919,9/9/2999,4.3,From 90.1-2016 Table 6.8.1-15 diff --git a/data/openstudio_standards_data/initial_data/level_1_space_types.csv b/data/openstudio_standards_data/initial_data/level_1_space_types.csv deleted file mode 100644 index 5c4109760b..0000000000 --- a/data/openstudio_standards_data/initial_data/level_1_space_types.csv +++ /dev/null @@ -1,129 +0,0 @@ -id,space_type_name,lighting_space_type_name,ventilation_space_type_name,electric_equipment_space_type_name -1,chapel - visually impaired,chapel_visually_impaired,public_assembly_spaces_religious_workshop, -2,recreation/common living - visually impaired,recreation_common_living_visually_impaired,hotels_motels_resorts_dormitories_multi_purpose_assembly, -3,atrium < 20 ft height,atrium_low,office_buildings_main_entry_lobbies,atrium < 20 ft height -4,atrium >= 20 ft and <= 40 ft in height,atrium_medium,office_buildings_main_entry_lobbies,atrium >= 20 ft and <= 40 ft in height -5,atrium > 40 ft height,atrium_high,office_buildings_main_entry_lobbies,atrium > 40 ft height -6,audience seating - convention center,audience_seating_convention_center,public_assembly_spaces_auditorium_seating_area,audience seating - convention center -7,audience seating - exercise center,audience_seating_exercise_center,sports_entertainment_spectator_areas,audience seating - exercise center -8,audience seating - all other,audience_seating_general,public_assembly_spaces_auditorium_seating_area,audience seating - all other -9,audience seating - auditorium,audience_seating_auditorium,public_assembly_spaces_auditorium_seating_area,audience seating - auditorium -10,audience seating - gymnasium,audience_seating_gymnasium,sports_entertainment_spectator_areas,audience seating - gymnasium -11,audience seating - sports arena,audience_seating_sports_arena,sports_entertainment_spectator_areas,audience seating - sports arena -12,audience seating - motion picture theater,audience_seating_motion_picture_theater,public_assembly_spaces_auditorium_seating_area,audience seating - motion picture theater -13,audience seating - penitentiary,audience_seating_penitentiary,public_assembly_spaces_auditorium_seating_area, -14,audience seating - performing arts theater,audience_seating_performing_arts_theater,public_assembly_spaces_auditorium_seating_area,audience seating - performing arts theater -15,audience seating - religious facility,audience_seating_religious_facility,public_assembly_spaces_auditorium_seating_area,audience seating - religious facility -16,audience seating - transportation facility,audience_seating_transportation,public_assembly_spaces_auditorium_seating_area, -17,automotive,automotive,miscellaneous_spaces_transportation_waiting, -18,banking activity,banking_activity,miscellaneous_spaces_banks_bank_lobbies,banking activity -19,classroom/lecture/training - all other,classroom_lecture_training_general,educational_facilities_classroom_old,classroom/lecture/training - all other -20,classroom/lecture/training - penitentiary,classroom_lecture_training_penitentiary,correctional_facilities_dayroom,classroom/lecture/training - penitentiary -21,classroom - laboratory or shop,laboratory_classroom,educational_facilities_university_college_laboratories, -22,classroom/lecture/training - preschool to 12th,classroom_lecture_training_general,educational_facilities_classroom_young,classroom/lecture/training - preschool to 12th -23,computer room,computer_room,miscellaneous_spaces_computer,computer room -24,conference/meeting/multipurpose,conference_meeting_multipurpose,general_conference_meeting,conference/meeting/multipurpose -25,confinement cells,confinement_cells,correctional_facilities_cell,confinement cells -26,exhibit - convention center,exhibit_convention_center,public_assembly_spaces_museums_galleries,exhibit - convention center -27,copy/print,copy_print,office_buildings_telephone_data_entry, -28,corridor for visually impaired,corridor_visually_impaired,general_conference_corridors, -29,corridor - hospital,corridor_hospital,general_conference_corridors,corridor - hospital -30,corridor - manufacturing facility,corridor_manufacturing_facility,general_conference_corridors,corridor - manufacturing facility -31,corridor - all other,corridor_general,general_conference_corridors,corridor - all other -32,courtroom,courtroom,public_assembly_spaces_courtrooms,courtroom -33,dining - all other,dining_general,food_beverage_service_restaurant_dining_rooms,dining - all other -34,dining - bar/lounge/leisure,dining_bar_lounge_leisure,food_beverage_service_bars_cocktail_lounges,dining - bar/lounge/leisure -35,dining - cafeteria/fast food,dining_cafeteria_fast_food,food_beverage_service_cafeteria_fast_food_dining,dining - cafeteria/fast food -36,dining for visually impaired,dining_visually_impaired,food_beverage_service_restaurant_dining_rooms, -37,dining - family,dining_family,food_beverage_service_restaurant_dining_rooms,dining - family -38,dining - penitentiary,dining_penitentiary,food_beverage_service_restaurant_dining_rooms,dining - penitentiary -39,dining - hotel,dining_hotel,food_beverage_service_restaurant_dining_rooms, -40,dining - motel,dining_motel,food_beverage_service_restaurant_dining_rooms, -41,dormitory - living quarters,dormitory_living_quarters,hotels_motels_resorts_dormitories_bedroom_living_room,dormitory - living quarters -42,electrical/mechanical,electrical_mechanical,miscellaneous_spaces_manufacturing_wo_hazardous_materials,electrical/mechanical -43,emergency vehicle garage,emergency_vehicle_garage,miscellaneous_spaces_transportation_waiting,emergency vehicle garage -44,firestation - sleeping quarters,firestation_sleeping_quarters,hotels_motels_resorts_dormitories_barracks_sleeping_areas,firestation - sleeping quarters -45,kitchen,kitchen,food_beverage_service_kitchen,kitchen -46,guest room,guest_room,hotels_motels_resorts_dormitories_barracks_sleeping_areas,guest room -47,gymnasium exercise area,gymnasium_exercise_area,sports_entertainment_gym_stadium,gymnasium exercise area -48,gymnasium playing area,gymnasium_playing_area,sports_entertainment_gym_stadium,gymnasium playing area -49,emergency room,emergency_room,outpatient_health_care_facilities_general_examination_room,emergency room -50,exam/treatment,exam_treatment,outpatient_health_care_facilities_general_examination_room,exam/treatment -51,imaging,imaging,outpatient_health_care_facilities_class_1_imaging_rooms, -52,medical supply,medical_supply,miscellaneous_spaces_pharmacy, -53,nursery,nursery,outpatient_health_care_facilities_psychiatric_consultation_room, -54,nurses station,nurses_station,outpatient_health_care_facilities_psychiatric_consultation_room,nurses station -55,operating room,operating_room,outpatient_health_care_facilities_general_examination_room,operating room -56,patient room,patient_room,outpatient_health_care_facilities_physical_therapy_individual_room,patient room -57,physical therapy,physical_therapy,outpatient_health_care_facilities_physical_therapy_exercise_area,physical therapy -58,recovery,recovery,outpatient_health_care_facilities_urgent_care_examination_room, -59,judges chambers,judges_chambers,public_assembly_spaces_legislative_chambers,judges chambers -60,laboratory,laboratory_all_other,educational_facilities_science_laboratories,laboratory -61,library - reading,library_reading,public_assembly_spaces_libraries,library - reading -62,library - stacks,library_stacks,public_assembly_spaces_libraries,library - stacks -63,library - cataloging,library_cataloging,public_assembly_spaces_libraries,library - cataloging -64,loading dock,loading_dock,miscellaneous_spaces_sorting_packing_light_assembly, -65,lobby - all other,lobby_general,public_assembly_spaces_lobbies,lobby - all other -66,lobby - elevator,lobby_elevator,public_assembly_spaces_lobbies,lobby - elevator -67,lobby for visually impaired,lobby_visually_impaired,public_assembly_spaces_lobbies, -68,lobby - hotel,lobby_hotel,hotels_motels_resorts_dormitories_lobbies_prefunction,lobby - hotel -69,lobby - motion picture theater,lobby_motion_picture_theater,public_assembly_spaces_lobbies,lobby - motion picture theater -70,lobby - performing arts theater,lobby_performing_arts_theater,public_assembly_spaces_lobbies,lobby - performing arts theater -71,locker room,locker_room,general_break_rooms,locker room -72,lounge/breakroom - all other,lounge_breakroom_general,general_break_rooms,lounge/breakroom - all other -73,lounge/breakroom - healthcare facility,lounge_breakroom_healthcare_facility,general_break_rooms,lounge/breakroom - healthcare facility -74,laundry/washing,laundry_washing,hotels_motels_resorts_dormitories_laundry_rooms,laundry/washing -75,detailed manufacuring,detailed_manufacuring,miscellaneous_spaces_manufacturing_wo_hazardous_materials, -76,manufacturing equipment room,manufacturing_equipment_room,miscellaneous_spaces_manufacturing_wo_hazardous_materials,manufacturing equipment room -77,manufacturing extra high bay,manufacturing_extra_high_bay,miscellaneous_spaces_manufacturing_wo_hazardous_materials, -78,manufacturing high bay,manufacturing_high_bay,miscellaneous_spaces_manufacturing_wo_hazardous_materials, -79,manufacturing low bay,manufacturing_low_bay,miscellaneous_spaces_manufacturing_wo_hazardous_materials,manufacturing low bay -80,manufacturing control,manufacturing_control,miscellaneous_spaces_manufacturing_wo_hazardous_materials, -81,museum exhibit area,museum_exhibit_area,public_assembly_spaces_museums_galleries,museum exhibit area -82,museum restoration,museum_restoration,public_assembly_spaces_museums_galleries,museum restoration -83,performing arts dressing room,performing_arts_dressing_room,retail_mall_common_areas,performing arts dressing room -84,office - enclosed <= 250 sf,office_enclosed_small,office_buildings_office_space,office - enclosed <= 250 sf -85,office - enclosed > 250 sf,office_enclosed_large,office_buildings_office_space,office - enclosed > 250 sf -86,office - open,office_open,office_buildings_office_space,office - open -87,"parking area, interior",parking_area_interior,miscellaneous_spaces_transportation_waiting,"parking area, interior" -88,pharmacy,pharmacy,miscellaneous_spaces_pharmacy,pharmacy -89,post office - sorting area,post_office_sorting_area,miscellaneous_spaces_sorting_packing_light_assembly,post office - sorting area -90,fellowship hall - religious facility,fellowship_hall_religious_facility,public_assembly_spaces_religious_workshop,fellowship hall - religious facility -91,worship/pulpit/choir area,worship_pulpit_choir_area,public_assembly_spaces_religious_workshop,worship/pulpit/choir area -92,restroom - all other,restroom_all_other,,restroom - all other -93,restroom - visually impaired,restroom_visually_impaired,, -94,retail dressing room,retail_dressing_room,retail_mall_common_areas, -95,retail mall concourse,retail_mall_concourse,retail_mall_common_areas, -96,"seating area, general",seating_area_general,public_assembly_spaces_auditorium_seating_area,"seating area, general" -97,"sports arena playing area, class I",sports_arena_playing_area_class_I,sports_entertainment_sports_arena, -98,"sports arena playing area, class II",sports_arena_playing_area_class_II,sports_entertainment_sports_arena,"sports arena playing area, class II" -99,"sports arena playing area, class III",sports_arena_playing_area_class_III,sports_entertainment_sports_arena, -100,"sports arena playing area, class IV",sports_arena_playing_area_class_IV,sports_entertainment_sports_arena,"sports arena playing area, class IV" -101,sports arena - ring sports area,sports_arena_ring_sports_area,sports_entertainment_sports_arena, -102,sports arena - court sports area,sports_arena_court_sports_area,sports_entertainment_sports_arena, -103,sports arena - indoor playing field,sports_arena_indoor_playing_field,sports_entertainment_sports_arena, -104,stairwell,stairwell,general_conference_corridors,stairwell -105,storage < 50 sf - all other,storage_ all_other_small,general_conference_storage_rooms,storage < 50 sf - all other -106,storage 50 to 1000 sf - all other,storage_ all_other_large,general_conference_storage_rooms,storage 50 to 1000 sf - all other -107,storage < 50 sf - hospital,storage_hospital_small,general_conference_storage_rooms,storage < 50 sf - hospital -108,storage 50 to 1000 sf - hospital,storage_hospital_large,general_conference_storage_rooms,storage 50 to 1000 sf - hospital -109,storage - inactive,storage_inactive,general_conference_storage_rooms,storage - inactive -110,"storage, inactive - museum",storage_inactive_museum,general_conference_storage_rooms, -111,airport concourse,airport_concourse,office_buildings_reception_areas,airport concourse -112,baggage/carousel,baggage_carousel,office_buildings_reception_areas,baggage/carousel -113,transportation ticket counter,transportation_ticket_counter,office_buildings_reception_areas,transportation ticket counter -114,vehicular maintenance,vehicular_maintenance,miscellaneous_spaces_manufacturing_wo_hazardous_materials,vehicular maintenance -115,warehouse - bulk storage,warehouse_bulk_storage,miscellaneous_spaces_warehouses,warehouse - bulk storage -116,warehouse - fine storage,warehouse_fine_storage,miscellaneous_spaces_warehouses,warehouse - fine storage -117,workshop,workshop,miscellaneous_spaces_manufacturing_wo_hazardous_materials,workshop -118,sales,sales,retail_sales,sales -119,sales - display type 1,sales_display_type_1,retail_sales, -120,sales - display type 2,sales_display_type_2,retail_sales, -121,sales - display type 3,sales_display_type_3,retail_sales, -122,sales - display type 4,sales_display_type_4,retail_sales, -123,guest room - highway,guest_room,hotels_motels_resorts_dormitories_barracks_sleeping_areas, -124,lodging dining - highway,dining_general,food_beverage_service_restaurant_dining_rooms, -125,audience seating - classroom/lecture/training,audience_seating_general,public_assembly_spaces_auditorium_seating_area, -126,audience seating - conference/meeting/multipurpose,audience_seating_general,public_assembly_spaces_auditorium_seating_area, -127,audience seating - corridor/transition,audience_seating_general,public_assembly_spaces_auditorium_seating_area, -128,guest room - bathroom,guest_room,hotels_motels_resorts_dormitories_barracks_sleeping_areas, diff --git a/data/openstudio_standards_data/initial_data/level_2_electric_equipment.csv b/data/openstudio_standards_data/initial_data/level_2_electric_equipment.csv deleted file mode 100644 index 47a8f8ba4e..0000000000 --- a/data/openstudio_standards_data/initial_data/level_2_electric_equipment.csv +++ /dev/null @@ -1,91 +0,0 @@ -id,electric_equipment_space_type_name,electric_equipment_minimum_epd,electric_equipment_average_epd,electric_equipment_median_epd,electric_equipment_maximum_epd,electric_equipment_epd_unit -1,corridor - all other,0,0.28,0.24,0.82,W/ft2 -2,dining - all other,0.32,0.55,0.55,0.82,W/ft2 -3,electrical/mechanical,0,0,0,0,W/ft2 -4,kitchen,0.3,0.76,0.71,2.52,W/ft2 -5,laboratory,0.49,0.78,0.7,2.02,W/ft2 -6,lobby - all other,0.16,0.41,0.35,0.83,W/ft2 -7,locker room,0,0.38,0.44,0.97,W/ft2 -8,lounge/breakroom - all other,0,0.49,0.52,0.88,W/ft2 -9,office - enclosed <= 250 sf,0.51,0.68,0.68,0.89,W/ft2 -10,office - enclosed > 250 sf,0.65,0.7,0.69,0.82,W/ft2 -11,office - open,0.53,0.66,0.67,0.81,W/ft2 -12,restroom - all other,0,0,0,0,W/ft2 -13,stairwell,0,0.25,0.25,0.53,W/ft2 -14,storage < 50 sf - all other,0,0,0,0,W/ft2 -15,storage 50 to 1000 sf - all other,0,0,0,0,W/ft2 -16,vehicular maintenance,0.65,0.69,0.69,0.73,W/ft2 -17,workshop,0,0.54,0.57,0.74,W/ft2 -18,atrium - first three floors,0,0.52,0.54,0.75,W/ft2 -19,audience seating - convention center,0.63,0.63,0.63,0.63,W/ft2 -20,classroom/lecture/training - all other,0.5,0.63,0.62,0.8,W/ft2 -21,conference/meeting/multipurpose,0.42,0.62,0.62,0.97,W/ft2 -22,exhibit - convention center,0.84,0.84,0.84,0.84,W/ft2 -23,gymnasium exercise area,0.27,0.48,0.49,0.68,W/ft2 -24,gymnasium playing area,0,0.51,0.51,1.06,W/ft2 -25,laundry/washing,0,0.39,0.39,0.59,W/ft2 -26,lobby - elevator,0.32,0.32,0.32,0.32,W/ft2 -27,nurses station,0,0.52,0.57,0.85,W/ft2 -28,post office - sorting area,0,0.23,0.24,0.39,W/ft2 -29,sales,0.41,0.67,0.67,0.92,W/ft2 -30,"sports arena playing area, class IV",0.32,0.5,0.64,0.69,W/ft2 -31,audience seating - all other,0.31,0.49,0.46,0.75,W/ft2 -32,confinement cells,0.22,0.26,0.26,0.32,W/ft2 -33,courtroom,0.25,0.4,0.4,0.56,W/ft2 -34,judges chambers,0.5,0.59,0.59,0.68,W/ft2 -35,library - stacks,0,0.2,0.2,0.33,W/ft2 -36,storage - inactive,0,0,0,0,W/ft2 -37,dining - bar/lounge/leisure,0.5,0.5,0.5,0.5,W/ft2 -38,dining - cafeteria/fast food,0.6,0.6,0.6,0.6,W/ft2 -39,dining - family,0.78,0.78,0.78,0.78,W/ft2 -40,computer room,0.69,0.7,0.69,0.73,W/ft2 -41,dormitory - living quarters,0.23,0.44,0.42,0.62,W/ft2 -42,audience seating - exercise center,0.6,0.6,0.6,0.6,W/ft2 -43,exam/treatment,0.51,0.56,0.53,0.66,W/ft2 -44,library - reading,0.32,0.49,0.46,0.71,W/ft2 -45,emergency vehicle garage,0.39,0.39,0.39,0.39,W/ft2 -46,firestation - sleeping quarters,0.37,0.37,0.37,0.37,W/ft2 -47,"parking area, interior",0.11,0.27,0.3,0.32,W/ft2 -48,audience seating - gymnasium,0.64,0.64,0.64,0.64,W/ft2 -49,emergency room,0.61,0.62,0.62,0.62,W/ft2 -50,patient room,0.71,0.72,0.72,0.73,W/ft2 -51,pharmacy,0.47,0.64,0.72,0.74,W/ft2 -52,corridor - hospital,0.3,0.3,0.3,0.3,W/ft2 -53,fellowship hall - religious facility,0.36,0.39,0.39,0.41,W/ft2 -54,lounge/breakroom - healthcare facility,0.75,0.75,0.75,0.75,W/ft2 -55,operating room,0.77,0.77,0.77,0.77,W/ft2 -56,physical therapy,0.73,0.73,0.73,0.73,W/ft2 -57,storage < 50 sf - hospital,0,0,0,0,W/ft2 -58,storage 50 to 1000 sf - hospital,0,0,0,0,W/ft2 -59,guest room,0.47,0.53,0.53,0.58,W/ft2 -60,lobby - hotel,0.5,0.5,0.5,0.5,W/ft2 -61,library - cataloging,0.21,0.21,0.21,0.21,W/ft2 -62,museum exhibit area,0.32,0.46,0.43,0.68,W/ft2 -63,corridor - manufacturing facility,0.38,0.38,0.38,0.38,W/ft2 -64,manufacturing equipment room,0,0,0,0,W/ft2 -65,manufacturing low bay,0.67,0.67,0.67,0.67,W/ft2 -66,performing arts dressing room,0.29,0.41,0.43,0.5,W/ft2 -67,audience seating - auditorium,0.26,0.29,0.29,0.32,W/ft2 -68,audience seating - motion picture theater,0.28,0.28,0.28,0.28,W/ft2 -69,lobby - motion picture theater,0.33,0.33,0.33,0.33,W/ft2 -70,Dwelling Unit,0.25,0.25,0.25,0.25,W/ft2 -71,museum restoration,0.21,0.21,0.21,0.21,W/ft2 -72,banking activity,0.54,0.55,0.55,0.56,W/ft2 -73,warehouse - fine storage,0,0.06,0.06,0.12,W/ft2 -74,classroom/lecture/training - penitentiary,0.41,0.41,0.41,0.41,W/ft2 -75,dining - penitentiary,0.35,0.35,0.35,0.35,W/ft2 -76,audience seating - performing arts theater,0.27,0.27,0.27,0.27,W/ft2 -77,lobby - performing arts theater,0.33,0.33,0.33,0.33,W/ft2 -78,audience seating - religious facility,0.41,0.41,0.41,0.41,W/ft2 -79,worship/pulpit/choir area,0.42,0.42,0.42,0.42,W/ft2 -80,classroom/lecture/training - preschool to 12th,0.67,0.67,0.67,0.67,W/ft2 -81,"sports arena playing area, class II",0.32,0.48,0.48,0.64,W/ft2 -82,audience seating - sports arena,0.38,0.38,0.38,0.38,W/ft2 -83,airport concourse,0.52,0.52,0.52,0.52,W/ft2 -84,atrium < 20 ft height,0.53,0.53,0.53,0.53,W/ft2 -85,atrium > 40 ft height,0.53,0.53,0.53,0.53,W/ft2 -86,atrium >= 20 ft and <= 40 ft in height,0.53,0.53,0.53,0.53,W/ft2 -87,baggage/carousel,0.55,0.55,0.55,0.55,W/ft2 -88,"seating area, general",0.25,0.25,0.25,0.25,W/ft2 -89,transportation ticket counter,0.74,0.74,0.74,0.74,W/ft2 -90,warehouse - bulk storage,0.11,0.11,0.11,0.11,W/ft2 diff --git a/data/openstudio_standards_data/initial_data/level_2_lighting_space_types.csv b/data/openstudio_standards_data/initial_data/level_2_lighting_space_types.csv deleted file mode 100644 index c9adbd41c9..0000000000 --- a/data/openstudio_standards_data/initial_data/level_2_lighting_space_types.csv +++ /dev/null @@ -1,287 +0,0 @@ -id,lighting_space_type_name,level_3_lighting_definition_table,level_3_lighting_defintion_id -1,bam_automotive_facility,level_3_lighting_90_1_2004,1 -2,bam_convention_center,level_3_lighting_90_1_2004,2 -3,bam_courthouse,level_3_lighting_90_1_2004,3 -4,bam_dinin_bar_lounge_leisure,level_3_lighting_90_1_2004,4 -5,bam_dining_cafeteria_fast_food,level_3_lighting_90_1_2004,5 -6,bam_dining_family,level_3_lighting_90_1_2004,6 -7,bam_dormitory,level_3_lighting_90_1_2004,7 -8,bam_exercise_center,level_3_lighting_90_1_2004,8 -9,bam_fire_station,level_3_lighting_90_1_2004,23 -10,bam_gymnasium,level_3_lighting_90_1_2004,9 -11,bam_healthcare_clinic,level_3_lighting_90_1_2004,10 -12,bam_hospital,level_3_lighting_90_1_2004,11 -13,bam_hotel,level_3_lighting_90_1_2004,12 -14,bam_library,level_3_lighting_90_1_2004,13 -15,bam_manufacturing_facility,level_3_lighting_90_1_2004,14 -16,bam_motel,level_3_lighting_90_1_2004,15 -17,bam_motion_picture_theater,level_3_lighting_90_1_2004,16 -18,bam_multifamily,level_3_lighting_90_1_2004,17 -19,bam_museum,level_3_lighting_90_1_2004,18 -20,bam_office,level_3_lighting_90_1_2004,19 -21,bam_parking_garage,level_3_lighting_90_1_2004,20 -22,bam_penitentiary,level_3_lighting_90_1_2004,21 -23,bam_performing_arts_theater,level_3_lighting_90_1_2004,22 -24,bam_police_station,level_3_lighting_90_1_2004,23 -25,bam_post_office,level_3_lighting_90_1_2004,24 -26,bam_religious_facility,level_3_lighting_90_1_2004,25 -27,bam_retail,level_3_lighting_90_1_2004,26 -28,bam_school_university,level_3_lighting_90_1_2004,27 -29,bam_sports_arena,level_3_lighting_90_1_2004,28 -30,bam_town_hall,level_3_lighting_90_1_2004,29 -31,bam_transportation,level_3_lighting_90_1_2004,30 -32,bam_warehouse,level_3_lighting_90_1_2004,31 -33,bam_workshop,level_3_lighting_90_1_2004,32 -34,office_enclosed_small,level_3_lighting_90_1_2004,33 -35,office_enclosed_large,level_3_lighting_90_1_2004,33 -36,office_open,level_3_lighting_90_1_2004,34 -37,conference_meeting_multipurpose,level_3_lighting_90_1_2004,35 -38,classroom_lecture_training_general,level_3_lighting_90_1_2004,36 -39,classroom_lecture_training_penitentiary,level_3_lighting_90_1_2004,37 -40,lobby_general,level_3_lighting_90_1_2004,38 -41,lobby_hotel,level_3_lighting_90_1_2004,39 -42,lobby_performing_arts_theater,level_3_lighting_90_1_2004,40 -43,lobby_motion_picture_theater,level_3_lighting_90_1_2004,41 -44,lobby_visually_impaired,level_3_lighting_90_1_2004,38 -45,lobby_elevator,level_3_lighting_90_1_2004,38 -46,audience_seating_general,level_3_lighting_90_1_2004,42 -47,audience_seating_gymnasium,level_3_lighting_90_1_2004,43 -48,audience_seating_exercise_center,level_3_lighting_90_1_2004,44 -49,audience_seating_convention_center,level_3_lighting_90_1_2004,45 -50,audience_seating_penitentiary,level_3_lighting_90_1_2004,46 -51,audience_seating_religious_facility,level_3_lighting_90_1_2004,47 -52,audience_seating_sports_arena,level_3_lighting_90_1_2004,48 -53,audience_seating_performing_arts_theater,level_3_lighting_90_1_2004,49 -54,audience_seating_motion_picture_theater,level_3_lighting_90_1_2004,50 -55,audience_seating_transportation,level_3_lighting_90_1_2004,51 -56,audience_seating_auditorium,level_3_lighting_90_1_2004,42 -57,atrium_first_three_floor,level_3_lighting_90_1_2004,52 -58,atrium_each_additional_floor,level_3_lighting_90_1_2004,53 -59,lounge_breakroom_general,level_3_lighting_90_1_2004,54 -60,lounge_breakroom_healthcare_facility,level_3_lighting_90_1_2004,55 -61,dining_general,level_3_lighting_90_1_2004,56 -62,dining_penitentiary,level_3_lighting_90_1_2004,57 -63,dining_hotel,level_3_lighting_90_1_2004,58 -64,dining_motel,level_3_lighting_90_1_2004,59 -65,dining_bar_lounge_leisure,level_3_lighting_90_1_2004,60 -66,dining_family,level_3_lighting_90_1_2004,61 -67,dining_cafeteria_fast_food,level_3_lighting_90_1_2004,56 -68,dining_visually_impaired,level_3_lighting_90_1_2004,56 -69,kitchen,level_3_lighting_90_1_2004,62 -70,laboratory_classroom,level_3_lighting_90_1_2004,63 -71,laboratory_all_other,level_3_lighting_90_1_2004,63 -72,restroom_visually_impaired,level_3_lighting_90_1_2004,64 -73,restroom_all_other,level_3_lighting_90_1_2004,64 -74,performing_arts_dressing_room,level_3_lighting_90_1_2004,65 -75,corridor_general,level_3_lighting_90_1_2004,66 -76,corridor_hospital,level_3_lighting_90_1_2004,67 -77,corridor_manufacturing_facility,level_3_lighting_90_1_2004,68 -78,corridor_visually_impaired,level_3_lighting_90_1_2004,66 -79,stairway,level_3_lighting_90_1_2004,69 -80,stairwell,level_3_lighting_90_1_2004,69 -81,storage_ all_other_small,level_3_lighting_90_1_2004,70 -82,storage_ all_other_large,level_3_lighting_90_1_2004,70 -83,storage_hospital_small,level_3_lighting_90_1_2004,71 -84,storage_hospital_large,level_3_lighting_90_1_2004,71 -85,storage_inactive,level_3_lighting_90_1_2004,72 -86,storage_inactive_museum,level_3_lighting_90_1_2004,73 -87,electrical_mechanical,level_3_lighting_90_1_2004,74 -88,workshop,level_3_lighting_90_1_2004,75 -89,gymnasium_playing_area,level_3_lighting_90_1_2004,76 -90,gymnasium_exercise_area,level_3_lighting_90_1_2004,77 -91,courtroom,level_3_lighting_90_1_2004,78 -92,confinement_cells,level_3_lighting_90_1_2004,79 -93,judges_chambers,level_3_lighting_90_1_2004,80 -94,emergency_vehicle_garage,level_3_lighting_90_1_2004,81 -95,firestation_sleeping_quarters,level_3_lighting_90_1_2004,82 -96,post_office_sorting_area,level_3_lighting_90_1_2004,83 -97,exhibit_convention_center,level_3_lighting_90_1_2004,84 -98,library_cataloging,level_3_lighting_90_1_2004,85 -99,library_stacks,level_3_lighting_90_1_2004,86 -100,library_reading,level_3_lighting_90_1_2004,87 -101,emergency_room,level_3_lighting_90_1_2004,88 -102,recovery,level_3_lighting_90_1_2004,89 -103,nurses_station,level_3_lighting_90_1_2004,90 -104,exam_treatment,level_3_lighting_90_1_2004,91 -105,pharmacy,level_3_lighting_90_1_2004,92 -106,patient_room,level_3_lighting_90_1_2004,93 -107,operating_room,level_3_lighting_90_1_2004,94 -108,nursery,level_3_lighting_90_1_2004,95 -109,medical_supply,level_3_lighting_90_1_2004,96 -110,physical_therapy,level_3_lighting_90_1_2004,97 -111,imaging,level_3_lighting_90_1_2004,98 -112,laundry_washing,level_3_lighting_90_1_2004,99 -113,automotive,level_3_lighting_90_1_2004,100 -114,manufacturing_low_bay,level_3_lighting_90_1_2004,101 -115,manufacturing_high_bay,level_3_lighting_90_1_2004,102 -116,detailed_manufacuring,level_3_lighting_90_1_2004,103 -117,manufacturing_equipment_room,level_3_lighting_90_1_2004,104 -118,manufacturing_control,level_3_lighting_90_1_2004,105 -119,guest_room,level_3_lighting_90_1_2004,106 -120,dormitory_living_quarters,level_3_lighting_90_1_2004,107 -121,museum_exhibit_area,level_3_lighting_90_1_2004,108 -122,museum_restoration,level_3_lighting_90_1_2004,109 -123,banking_activity,level_3_lighting_90_1_2004,110 -124,worship_pulpit_choir_area,level_3_lighting_90_1_2004,111 -125,fellowship_hall_religious_facility,level_3_lighting_90_1_2004,112 -126,sales,level_3_lighting_90_1_2004,113 -127,retail_mall_concourse,level_3_lighting_90_1_2004,114 -128,sports_arena_ring_sports_area,level_3_lighting_90_1_2004,115 -129,sports_arena_court_sports_area,level_3_lighting_90_1_2004,116 -130,sports_arena_indoor_playing_field,level_3_lighting_90_1_2004,117 -131,warehouse_bulk_storage,level_3_lighting_90_1_2004,119 -132,parking_area_interior,level_3_lighting_90_1_2004,120 -133,airport_concourse,level_3_lighting_90_1_2004,121 -134,baggage_carousel,level_3_lighting_90_1_2004,122 -135,transportation_ticket_counter,level_3_lighting_90_1_2004,123 -136,sales_display_type_1,level_3_lighting_90_1_2004,124 -137,sales_display_type_2,level_3_lighting_90_1_2004,124 -138,sales_display_type_3,level_3_lighting_90_1_2004,125 -139,sales_display_type_4,level_3_lighting_90_1_2004,125 -140,bam_automotive_facility,level_3_lighting_90_1_2019,1 -141,bam_convention_center,level_3_lighting_90_1_2019,2 -142,bam_courthouse,level_3_lighting_90_1_2019,3 -143,bam_dinin_bar_lounge_leisure,level_3_lighting_90_1_2019,4 -144,bam_dining_cafeteria_fast_food,level_3_lighting_90_1_2019,5 -145,bam_dining_family,level_3_lighting_90_1_2019,6 -146,bam_dormitory,level_3_lighting_90_1_2019,7 -147,bam_exercise_center,level_3_lighting_90_1_2019,8 -148,bam_fire_station,level_3_lighting_90_1_2019,9 -149,bam_gymnasium,level_3_lighting_90_1_2019,10 -150,bam_healthcare_clinic,level_3_lighting_90_1_2019,11 -151,bam_hospital,level_3_lighting_90_1_2019,12 -152,bam_hotel,level_3_lighting_90_1_2019,13 -153,bam_library,level_3_lighting_90_1_2019,14 -154,bam_manufacturing_facility,level_3_lighting_90_1_2019,15 -155,bam_motel,level_3_lighting_90_1_2019,13 -156,bam_motion_picture_theater,level_3_lighting_90_1_2019,16 -157,bam_multifamily,level_3_lighting_90_1_2019,17 -158,bam_museum,level_3_lighting_90_1_2019,18 -159,bam_office,level_3_lighting_90_1_2019,19 -160,bam_parking_garage,level_3_lighting_90_1_2019,20 -161,bam_penitentiary,level_3_lighting_90_1_2019,21 -162,bam_performing_arts_theater,level_3_lighting_90_1_2019,22 -163,bam_police_station,level_3_lighting_90_1_2019,23 -164,bam_post_office,level_3_lighting_90_1_2019,24 -165,bam_religious_facility,level_3_lighting_90_1_2019,25 -166,bam_retail,level_3_lighting_90_1_2019,26 -167,bam_school_university,level_3_lighting_90_1_2019,27 -168,bam_sports_arena,level_3_lighting_90_1_2019,28 -169,bam_town_hall,level_3_lighting_90_1_2019,29 -170,bam_transportation,level_3_lighting_90_1_2019,30 -171,bam_warehouse,level_3_lighting_90_1_2019,31 -172,bam_workshop,level_3_lighting_90_1_2019,32 -173,office_enclosed_small,level_3_lighting_90_1_2019,79 -174,office_enclosed_large,level_3_lighting_90_1_2019,80 -175,office_open,level_3_lighting_90_1_2019,81 -176,conference_meeting_multipurpose,level_3_lighting_90_1_2019,48 -177,classroom_lecture_training_general,level_3_lighting_90_1_2019,47 -178,classroom_lecture_training_penitentiary,level_3_lighting_90_1_2019,46 -179,lobby_general,level_3_lighting_90_1_2019,75 -180,lobby_hotel,level_3_lighting_90_1_2019,72 -181,lobby_performing_arts_theater,level_3_lighting_90_1_2019,74 -182,lobby_motion_picture_theater,level_3_lighting_90_1_2019,73 -183,lobby_visually_impaired,level_3_lighting_90_1_2019,70 -184,lobby_elevator,level_3_lighting_90_1_2019,71 -185,audience_seating_general,level_3_lighting_90_1_2019,43 -186,audience_seating_gymnasium,level_3_lighting_90_1_2019,37 -187,audience_seating_exercise_center,level_3_lighting_90_1_2019,43 -188,audience_seating_convention_center,level_3_lighting_90_1_2019,43 -189,audience_seating_penitentiary,level_3_lighting_90_1_2019,39 -190,audience_seating_religious_facility,level_3_lighting_90_1_2019,41 -191,audience_seating_sports_arena,level_3_lighting_90_1_2019,42 -192,audience_seating_performing_arts_theater,level_3_lighting_90_1_2019,40 -193,audience_seating_motion_picture_theater,level_3_lighting_90_1_2019,38 -194,audience_seating_transportation,level_3_lighting_90_1_2019,43 -195,audience_seating_auditorium,level_3_lighting_90_1_2019,36 -196,atrium_low,level_3_lighting_90_1_2019,33 -197,atrium_medium,level_3_lighting_90_1_2019,34 -198,atrium_high,level_3_lighting_90_1_2019,35 -199,lounge_breakroom_general,level_3_lighting_90_1_2019,78 -200,lounge_breakroom_healthcare_facility,level_3_lighting_90_1_2019,77 -201,dining_general,level_3_lighting_90_1_2019,61 -202,dining_penitentiary,level_3_lighting_90_1_2019,56 -203,dining_hotel,level_3_lighting_90_1_2019,61 -204,dining_motel,level_3_lighting_90_1_2019,61 -205,dining_bar_lounge_leisure,level_3_lighting_90_1_2019,58 -206,dining_family,level_3_lighting_90_1_2019,60 -207,dining_cafeteria_fast_food,level_3_lighting_90_1_2019,59 -208,dining_visually_impaired,level_3_lighting_90_1_2019,57 -209,kitchen,level_3_lighting_90_1_2019,64 -210,laboratory_classroom,level_3_lighting_90_1_2019,66 -211,laboratory_all_other,level_3_lighting_90_1_2019,67 -212,restroom_visually_impaired,level_3_lighting_90_1_2019,84 -213,restroom_all_other,level_3_lighting_90_1_2019,85 -214,performing_arts_dressing_room,level_3_lighting_90_1_2019,120 -215,corridor_general,level_3_lighting_90_1_2019,53 -216,corridor_hospital,level_3_lighting_90_1_2019,52 -217,corridor_manufacturing_facility,level_3_lighting_90_1_2019,53 -218,corridor_visually_impaired,level_3_lighting_90_1_2019,51 -219,stairway,level_3_lighting_90_1_2019,88 -220,stairwell,level_3_lighting_90_1_2019,89 -221,storage_ all_other_small,level_3_lighting_90_1_2019,90 -222,storage_ all_other_large,level_3_lighting_90_1_2019,91 -223,storage_hospital_small,level_3_lighting_90_1_2019,90 -224,storage_hospital_large,level_3_lighting_90_1_2019,91 -225,electrical_mechanical,level_3_lighting_90_1_2019,62 -226,workshop,level_3_lighting_90_1_2019,93 -227,gymnasium_playing_area,level_3_lighting_90_1_2019,101 -228,gymnasium_exercise_area,level_3_lighting_90_1_2019,100 -229,courtroom,level_3_lighting_90_1_2019,54 -230,confinement_cells,level_3_lighting_90_1_2019,49 -231,emergency_vehicle_garage,level_3_lighting_90_1_2019,63 -232,firestation_sleeping_quarters,level_3_lighting_90_1_2019,99 -233,post_office_sorting_area,level_3_lighting_90_1_2019,121 -234,exhibit_convention_center,level_3_lighting_90_1_2019,97 -235,library_stacks,level_3_lighting_90_1_2019,112 -236,library_reading,level_3_lighting_90_1_2019,111 -237,recovery,level_3_lighting_90_1_2019,110 -238,nurses_station,level_3_lighting_90_1_2019,106 -239,exam_treatment,level_3_lighting_90_1_2019,102 -240,pharmacy,level_3_lighting_90_1_2019,83 -241,patient_room,level_3_lighting_90_1_2019,108 -242,operating_room,level_3_lighting_90_1_2019,107 -243,nursery,level_3_lighting_90_1_2019,105 -244,medical_supply,level_3_lighting_90_1_2019,104 -245,physical_therapy,level_3_lighting_90_1_2019,109 -246,imaging,level_3_lighting_90_1_2019,103 -247,laundry_washing,level_3_lighting_90_1_2019,68 -248,automotive,level_3_lighting_90_1_2019,96 -249,manufacturing_low_bay,level_3_lighting_90_1_2019,117 -250,manufacturing_high_bay,level_3_lighting_90_1_2019,116 -251,detailed_manufacuring,level_3_lighting_90_1_2019,113 -252,manufacturing_equipment_room,level_3_lighting_90_1_2019,114 -253,manufacturing_extra_high_bay,level_3_lighting_90_1_2019,115 -254,guest_room,level_3_lighting_90_1_2019,65 -255,dormitory_living_quarters,level_3_lighting_90_1_2019,98 -256,museum_exhibit_area,level_3_lighting_90_1_2019,118 -257,museum_restoration,level_3_lighting_90_1_2019,119 -258,banking_activity,level_3_lighting_90_1_2019,44 -259,worship_pulpit_choir_area,level_3_lighting_90_1_2019,123 -260,fellowship_hall_religious_facility,level_3_lighting_90_1_2019,122 -261,sales,level_3_lighting_90_1_2019,86 -262,retail_mall_concourse,level_3_lighting_90_1_2019,125 -263,retail_dressing_room,level_3_lighting_90_1_2019,124 -264,sports_arena_playing_area_class_I,level_3_lighting_90_1_2019,126 -265,sports_arena_playing_area_class_II,level_3_lighting_90_1_2019,127 -266,sports_arena_playing_area_class_III,level_3_lighting_90_1_2019,128 -267,sports_arena_playing_area_class_IV,level_3_lighting_90_1_2019,129 -268,warehouse_fine_storage,level_3_lighting_90_1_2019,134 -269,warehouse_bulk_storage,level_3_lighting_90_1_2019,133 -270,parking_area_interior,level_3_lighting_90_1_2019,82 -271,airport_concourse,level_3_lighting_90_1_2019,131 -272,baggage_carousel,level_3_lighting_90_1_2019,130 -273,transportation_ticket_counter,level_3_lighting_90_1_2019,132 -274,sales_display_type_1,level_3_lighting_90_1_2019,135 -275,sales_display_type_2,level_3_lighting_90_1_2019,136 -276,sales_display_type_3,level_3_lighting_90_1_2019,137 -277,sales_display_type_4,level_3_lighting_90_1_2019,138 -278,breakroom,level_3_lighting_90_1_2019,45 -279,copy_print,level_3_lighting_90_1_2019,50 -280,computer_room,level_3_lighting_90_1_2019,55 -281,loading_dock,level_3_lighting_90_1_2019,69 -282,locker_room,level_3_lighting_90_1_2019,76 -283,seating_area_general,level_3_lighting_90_1_2019,87 -284,vehicular_maintenance,level_3_lighting_90_1_2019,92 -285,chapel_visually_impaired,level_3_lighting_90_1_2019,94 -286,recreation_common_living_visually_impaired,level_3_lighting_90_1_2019,95 diff --git a/data/openstudio_standards_data/initial_data/level_2_ventilation_space_types.csv b/data/openstudio_standards_data/initial_data/level_2_ventilation_space_types.csv deleted file mode 100644 index 816a1d9cc9..0000000000 --- a/data/openstudio_standards_data/initial_data/level_2_ventilation_space_types.csv +++ /dev/null @@ -1,174 +0,0 @@ -id,ventilation_space_type_name,level_3_ventilation_definition_table,level_3_ventilation_defintion_id -1,correctional_facilities_cell,level_3_ventilation_90_1_2019,13 -2,correctional_facilities_dayroom,level_3_ventilation_90_1_2019,14 -3,correctional_facilities_guard_stations,level_3_ventilation_90_1_2019,15 -4,correctional_facilities_booking_waiting,level_3_ventilation_90_1_2019,12 -5,educational_facilities_daycare,level_3_ventilation_90_1_2019,21 -6,educational_facilities_classroom_young,level_3_ventilation_90_1_2019,17 -7,educational_facilities_classroom_old,level_3_ventilation_90_1_2019,18 -8,educational_facilities_lecture_classroom,level_3_ventilation_90_1_2019,22 -9,educational_facilities_lecture_hall,level_3_ventilation_90_1_2019,23 -10,educational_facilities_art_classroom,level_3_ventilation_90_1_2019,16 -11,educational_facilities_science_laboratories,level_3_ventilation_90_1_2019,28 -12,educational_facilities_wood_metal_shop,level_3_ventilation_90_1_2019,30 -13,educational_facilities_computer_lab,level_3_ventilation_90_1_2019,19 -14,educational_facilities_media_center,level_3_ventilation_90_1_2019,25 -15,educational_facilities_music_theater_dance,level_3_ventilation_90_1_2019,27 -16,educational_facilities_multiuse_assembly,level_3_ventilation_90_1_2019,26 -17,educational_facilities_daycare_sickroom,level_3_ventilation_90_1_2019,20 -18,educational_facilities_libraries,level_3_ventilation_90_1_2019,24 -19,educational_facilities_university_college_laboratories,level_3_ventilation_90_1_2019,29 -20,food_beverage_service_restaurant_dining_rooms,level_3_ventilation_90_1_2019,34 -21,food_beverage_service_cafeteria_fast_food_dining,level_3_ventilation_90_1_2019,32 -22,food_beverage_service_bars_cocktail_lounges,level_3_ventilation_90_1_2019,31 -23,food_beverage_service_kitchen,level_3_ventilation_90_1_2019,33 -24,general_conference_meeting,level_3_ventilation_90_1_2019,37 -25,general_conference_corridors,level_3_ventilation_90_1_2019,38 -26,general_conference_storage_rooms,level_3_ventilation_90_1_2019,39 -27,general_break_rooms,level_3_ventilation_90_1_2019,35 -28,general_coffee_stations,level_3_ventilation_90_1_2019,36 -29,hotels_motels_resorts_dormitories_bedroom_living_room,level_3_ventilation_90_1_2019,41 -30,hotels_motels_resorts_dormitories_barracks_sleeping_areas,level_3_ventilation_90_1_2019,40 -31,hotels_motels_resorts_dormitories_lobbies_prefunction,level_3_ventilation_90_1_2019,44 -32,hotels_motels_resorts_dormitories_multi_purpose_assembly,level_3_ventilation_90_1_2019,45 -33,hotels_motels_resorts_dormitories_laundry_rooms,level_3_ventilation_90_1_2019,42 -34,hotels_motels_resorts_dormitories_laundry_rooms_w_dwelling_units,level_3_ventilation_90_1_2019,43 -35,office_buildings_office_space,level_3_ventilation_90_1_2019,62 -36,office_buildings_reception_areas,level_3_ventilation_90_1_2019,63 -37,office_buildings_telephone_data_entry,level_3_ventilation_90_1_2019,64 -38,office_buildings_main_entry_lobbies,level_3_ventilation_90_1_2019,60 -39,office_buildings_breakrooms,level_3_ventilation_90_1_2019,59 -40,office_buildings_occupiable_storage_rooms,level_3_ventilation_90_1_2019,61 -41,miscellaneous_spaces_bank_ vaults_safe_deposit,level_3_ventilation_90_1_2019,47 -42,miscellaneous_spaces_computer,level_3_ventilation_90_1_2019,48 -43,miscellaneous_spaces_pharmacy,level_3_ventilation_90_1_2019,52 -44,miscellaneous_spaces_photo_studios,level_3_ventilation_90_1_2019,53 -45,miscellaneous_spaces_shipping_receiving,level_3_ventilation_90_1_2019,54 -46,miscellaneous_spaces_transportation_waiting,level_3_ventilation_90_1_2019,57 -47,miscellaneous_spaces_warehouses,level_3_ventilation_90_1_2019,58 -48,miscellaneous_spaces_banks_bank_lobbies,level_3_ventilation_90_1_2019,46 -49,miscellaneous_spaces_freezer_refrigerated_spaces,level_3_ventilation_90_1_2019,49 -50,miscellaneous_spaces_manufacturing_wo_hazardous_materials,level_3_ventilation_90_1_2019,50 -51,miscellaneous_spaces_manufacturing_w_hazardous_materials,level_3_ventilation_90_1_2019,51 -52,miscellaneous_spaces_sorting_packing_light_assembly,level_3_ventilation_90_1_2019,55 -53,miscellaneous_spaces_telephone_closets,level_3_ventilation_90_1_2019,56 -54,public_assembly_spaces_auditorium_seating_area,level_3_ventilation_90_1_2019,83 -55,public_assembly_spaces_religious_workshop,level_3_ventilation_90_1_2019,90 -56,public_assembly_spaces_courtrooms,level_3_ventilation_90_1_2019,84 -57,public_assembly_spaces_legislative_chambers,level_3_ventilation_90_1_2019,85 -58,public_assembly_spaces_libraries,level_3_ventilation_90_1_2019,86 -59,public_assembly_spaces_lobbies,level_3_ventilation_90_1_2019,87 -60,public_assembly_spaces_children_museums,level_3_ventilation_90_1_2019,88 -61,public_assembly_spaces_museums_galleries,level_3_ventilation_90_1_2019,89 -62,retail_sales,level_3_ventilation_90_1_2019,91 -63,retail_mall_common_areas,level_3_ventilation_90_1_2019,95 -64,retail_barbershop,level_3_ventilation_90_1_2019,92 -65,retail_beauty_nail_salons,level_3_ventilation_90_1_2019,93 -66,retail_pet_shops,level_3_ventilation_90_1_2019,96 -67,retail_supermarket,level_3_ventilation_90_1_2019,97 -68,retail_coin_operated_laundries,level_3_ventilation_90_1_2019,94 -69,sports_entertainment_sports_arena,level_3_ventilation_90_1_2019,102 -70,sports_entertainment_gym_stadium,level_3_ventilation_90_1_2019,102 -71,sports_entertainment_spectator_areas,level_3_ventilation_90_1_2019,105 -72,sports_entertainment_swimming,level_3_ventilation_90_1_2019,107 -73,sports_entertainment_disco_dance_floors,level_3_ventilation_90_1_2019,99 -74,sports_entertainment_health_club_aerobics_room,level_3_ventilation_90_1_2019,103 -75,sports_entertainment_health_club_weight_rooms,level_3_ventilation_90_1_2019,104 -76,sports_entertainment_bowling_alley,level_3_ventilation_90_1_2019,98 -77,sports_entertainment_gambling_casinos,level_3_ventilation_90_1_2019,100 -78,sports_entertainment_game_arcades,level_3_ventilation_90_1_2019,101 -79,sports_entertainment_stages_studios,level_3_ventilation_90_1_2019,106 -80,animal_facilities_animal_exam_room,level_3_ventilation_90_1_2019,1 -81,animal_facilities_animal_imaging,level_3_ventilation_90_1_2019,2 -82,animal_facilities_animal_operating_rooms,level_3_ventilation_90_1_2019,3 -83,animal_facilities_animal_postoperative_recovery_room,level_3_ventilation_90_1_2019,4 -84,animal_facilities_animal_preparation_rooms,level_3_ventilation_90_1_2019,5 -85,animal_facilities_animal_procedure_room,level_3_ventilation_90_1_2019,6 -86,animal_facilities_animal_surgery_scrub,level_3_ventilation_90_1_2019,7 -87,animal_facilities_large_animal_holding_room,level_3_ventilation_90_1_2019,8 -88,animal_facilities_necropsy,level_3_ventilation_90_1_2019,9 -89,animal_facilities_small_animal_cage_room_static,level_3_ventilation_90_1_2019,10 -90,animal_facilities_small_animal_cage_room_ventilated,level_3_ventilation_90_1_2019,11 -91,outpatient_health_care_facilities_birthing_room,level_3_ventilation_90_1_2019,65 -92,outpatient_health_care_facilities_class_1_imaging_rooms,level_3_ventilation_90_1_2019,66 -93,outpatient_health_care_facilities_dental_operatory,level_3_ventilation_90_1_2019,67 -94,outpatient_health_care_facilities_general_examination_room,level_3_ventilation_90_1_2019,68 -95,outpatient_health_care_facilities_other_dental_treatment_areas,level_3_ventilation_90_1_2019,69 -96,outpatient_health_care_facilities_physical_therapy_exercise_area,level_3_ventilation_90_1_2019,70 -97,outpatient_health_care_facilities_physical_therapy_individual_room,level_3_ventilation_90_1_2019,71 -98,outpatient_health_care_facilities_physical_therapeutic_pool_area,level_3_ventilation_90_1_2019,72 -99,outpatient_health_care_facilities_prosthetics_orthotics_room,level_3_ventilation_90_1_2019,73 -100,outpatient_health_care_facilities_psychiatric_consultation_room,level_3_ventilation_90_1_2019,74 -101,outpatient_health_care_facilities_psychiatric_examination_room,level_3_ventilation_90_1_2019,75 -102,outpatient_health_care_facilities_psychiatric_group_room,level_3_ventilation_90_1_2019,76 -103,outpatient_health_care_facilities_psychiatric_seclusion_room,level_3_ventilation_90_1_2019,77 -104,outpatient_health_care_facilities_speech_therapy_room,level_3_ventilation_90_1_2019,78 -105,outpatient_health_care_facilities_urgent_care_examination_room,level_3_ventilation_90_1_2019,79 -106,outpatient_health_care_facilities_urgent_care_observation_room,level_3_ventilation_90_1_2019,80 -107,outpatient_health_care_facilities_urgent_care_treatment_room,level_3_ventilation_90_1_2019,81 -108,outpatient_health_care_facilities_urgent_care_triage_room,level_3_ventilation_90_1_2019,82 -109,transient_residential_common_corridors,level_3_ventilation_90_1_2019,108 -110,transient_residential_dwelling_unit,level_3_ventilation_90_1_2019,109 -111,correctional_facilities_cell,level_3_ventilation_90_1_2004,1 -112,correctional_facilities_dayroom,level_3_ventilation_90_1_2004,2 -113,correctional_facilities_guard_stations,level_3_ventilation_90_1_2004,3 -114,correctional_facilities_booking_waiting,level_3_ventilation_90_1_2004,4 -115,educational_facilities_daycare,level_3_ventilation_90_1_2004,5 -116,educational_facilities_classroom_young,level_3_ventilation_90_1_2004,6 -117,educational_facilities_classroom_old,level_3_ventilation_90_1_2004,7 -118,educational_facilities_lecture_classroom,level_3_ventilation_90_1_2004,8 -119,educational_facilities_lecture_hall,level_3_ventilation_90_1_2004,9 -120,educational_facilities_art_classroom,level_3_ventilation_90_1_2004,10 -121,educational_facilities_science_laboratories,level_3_ventilation_90_1_2004,11 -122,educational_facilities_wood_metal_shop,level_3_ventilation_90_1_2004,12 -123,educational_facilities_computer_lab,level_3_ventilation_90_1_2004,13 -124,educational_facilities_media_center,level_3_ventilation_90_1_2004,14 -125,educational_facilities_music_theater_dance,level_3_ventilation_90_1_2004,15 -126,educational_facilities_multiuse_assembly,level_3_ventilation_90_1_2004,16 -127,food_beverage_service_restaurant_dining_rooms,level_3_ventilation_90_1_2004,17 -128,food_beverage_service_cafeteria_fast_food_dining,level_3_ventilation_90_1_2004,18 -129,food_beverage_service_bars_cocktail_lounges,level_3_ventilation_90_1_2004,19 -130,general_conference_meeting,level_3_ventilation_90_1_2004,20 -131,general_conference_corridors,level_3_ventilation_90_1_2004,21 -132,general_conference_storage_rooms,level_3_ventilation_90_1_2004,22 -133,hotels_motels_resorts_dormitories_bedroom_living_room,level_3_ventilation_90_1_2004,23 -134,hotels_motels_resorts_dormitories_barracks_sleeping_areas,level_3_ventilation_90_1_2004,24 -135,hotels_motels_resorts_dormitories_lobbies_prefunction,level_3_ventilation_90_1_2004,25 -136,hotels_motels_resorts_dormitories_multi_purpose_assembly,level_3_ventilation_90_1_2004,26 -137,office_buildings_office_space,level_3_ventilation_90_1_2004,27 -138,office_buildings_reception_areas,level_3_ventilation_90_1_2004,28 -139,office_buildings_telephone_data_entry,level_3_ventilation_90_1_2004,29 -140,office_buildings_main_entry_lobbies,level_3_ventilation_90_1_2004,30 -141,miscellaneous_spaces_bank_ vaults_safe_deposit,level_3_ventilation_90_1_2004,31 -142,miscellaneous_spaces_computer,level_3_ventilation_90_1_2004,32 -143,miscellaneous_spaces_pharmacy,level_3_ventilation_90_1_2004,33 -144,miscellaneous_spaces_photo_studios,level_3_ventilation_90_1_2004,34 -145,miscellaneous_spaces_shipping_receiving,level_3_ventilation_90_1_2004,35 -146,miscellaneous_spaces_transportation_waiting,level_3_ventilation_90_1_2004,36 -147,miscellaneous_spaces_warehouses,level_3_ventilation_90_1_2004,37 -148,public_assembly_spaces_auditorium_seating_area,level_3_ventilation_90_1_2004,38 -149,public_assembly_spaces_religious_workshop,level_3_ventilation_90_1_2004,39 -150,public_assembly_spaces_courtrooms,level_3_ventilation_90_1_2004,40 -151,public_assembly_spaces_legislative_chambers,level_3_ventilation_90_1_2004,41 -152,public_assembly_spaces_libraries,level_3_ventilation_90_1_2004,42 -153,public_assembly_spaces_lobbies,level_3_ventilation_90_1_2004,43 -154,public_assembly_spaces_children_museums,level_3_ventilation_90_1_2004,44 -155,public_assembly_spaces_museums_galleries,level_3_ventilation_90_1_2004,45 -156,retail_sales,level_3_ventilation_90_1_2004,46 -157,retail_mall_common_areas,level_3_ventilation_90_1_2004,47 -158,retail_barbershop,level_3_ventilation_90_1_2004,48 -159,retail_beauty_nail_salons,level_3_ventilation_90_1_2004,49 -160,retail_pet_shops,level_3_ventilation_90_1_2004,50 -161,retail_supermarket,level_3_ventilation_90_1_2004,51 -162,retail_coin_operated_laundries,level_3_ventilation_90_1_2004,52 -163,sports_entertainment_sports_arena,level_3_ventilation_90_1_2004,53 -164,sports_entertainment_gym_stadium,level_3_ventilation_90_1_2004,54 -165,sports_entertainment_spectator_areas,level_3_ventilation_90_1_2004,55 -166,sports_entertainment_swimming,level_3_ventilation_90_1_2004,56 -167,sports_entertainment_disco_dance_floors,level_3_ventilation_90_1_2004,57 -168,sports_entertainment_health_club_aerobics_room,level_3_ventilation_90_1_2004,58 -169,sports_entertainment_health_club_weight_rooms,level_3_ventilation_90_1_2004,59 -170,sports_entertainment_bowling_alley,level_3_ventilation_90_1_2004,60 -171,sports_entertainment_gambling_casinos,level_3_ventilation_90_1_2004,61 -172,sports_entertainment_game_arcades,level_3_ventilation_90_1_2004,62 -173,sports_entertainment_stages_studios,level_3_ventilation_90_1_2004,63 diff --git a/data/openstudio_standards_data/initial_data/level_3_lighting_90_1_2004.csv b/data/openstudio_standards_data/initial_data/level_3_lighting_90_1_2004.csv deleted file mode 100644 index c970952f1c..0000000000 --- a/data/openstudio_standards_data/initial_data/level_3_lighting_90_1_2004.csv +++ /dev/null @@ -1,126 +0,0 @@ -id,method,lighting_primary_space_type,lighting_per_area,lighting_secondary_space_type,lighting_per_area_unit,annotation -1,BA,Automotive Facility,0.9,General,W/ft2, -2,BA,Convention Center,1.2,General,W/ft2, -3,BA,Court House,1.2,General,W/ft2, -4,BA,Dining: Bar Lounge/Leisure,1.3,General,W/ft2, -5,BA,Dining: Cafeteria/Fast Food,1.4,General,W/ft2, -6,BA,Dining: Family,1.6,General,W/ft2, -7,BA,Dormitory,1,General,W/ft2, -8,BA,Exercise Center,1,General,W/ft2, -9,BA,Gymnasium,1.1,General,W/ft2, -10,BA,Health Care-Clinic,1,General,W/ft2, -11,BA,Hospital,1.2,General,W/ft2, -12,BA,Hotel,1,General,W/ft2, -13,BA,Library,1.3,General,W/ft2, -14,BA,Manufacturing Facility,1.3,General,W/ft2, -15,BA,Motel,1,General,W/ft2, -16,BA,Motion Picture Theater,1.2,General,W/ft2, -17,BA,Multi-Family,0.7,General,W/ft2, -18,BA,Museum,1.1,General,W/ft2, -19,BA,Office,1,General,W/ft2, -20,BA,Parking Garage,0.3,General,W/ft2, -21,BA,Penitentiary,1,General,W/ft2, -22,BA,Performing Arts Theater,1.6,General,W/ft2, -23,BA,Police/Fire Station,1,General,W/ft2, -24,BA,Post Office,1.1,General,W/ft2, -25,BA,Religious Building,1.3,General,W/ft2, -26,BA,Retail,1.5,General,W/ft2, -27,BA,School/University,1.2,General,W/ft2, -28,BA,Sports Arena,1.1,General,W/ft2, -29,BA,Town Hall,1.1,General,W/ft2, -30,BA,Transportation,1,General,W/ft2, -31,BA,Warehouse,0.8,General,W/ft2, -32,BA,Workshop,1.4,General,W/ft2, -33,CS,Office-Enclosed,1.1,General,W/ft2, -34,CS,Office-Open Plan,1.1,General,W/ft2, -35,CS,Conference/Meeting/Multipurpose,1.3,General,W/ft2, -36,CS,Classroom/Lecture/Training,1.4,General,W/ft2, -37,CS,Classroom/Lecture/Training,1.3,For Penitentiary,W/ft2, -38,CS,Lobby,1.3,General,W/ft2, -39,CS,Lobby,1.1,For Hotel,W/ft2, -40,CS,Lobby,3.3,For Performing Arts Theater,W/ft2, -41,CS,Lobby,1.1,For Motion Picture Theater,W/ft2, -42,CS,Audience/Seating Area,0.9,General,W/ft2, -43,CS,Audience/Seating Area,0.4,For Gymnasium,W/ft2, -44,CS,Audience/Seating Area,0.3,For Exercise Center,W/ft2, -45,CS,Audience/Seating Area,0.7,For Convention Center,W/ft2, -46,CS,Audience/Seating Area,0.7,For Penitentiary,W/ft2, -47,CS,Audience/Seating Area,1.7,For Religious Buildings,W/ft2, -48,CS,Audience/Seating Area,0.4,For Sports Arena,W/ft2, -49,CS,Audience/Seating Area,2.6,For Performing Arts Theater,W/ft2, -50,CS,Audience/Seating Area,1.2,For Motion Picture Theater,W/ft2, -51,CS,Audience/Seating Area,0.5,For Transportation,W/ft2, -52,CS,Atrium: First Three Floors,0.6,General,W/ft2, -53,CS,Atrium: Each Additional Floor,0.2,General,W/ft2, -54,CS,Lounge/Recreation,1.2,General,W/ft2, -55,CS,Lounge/Recreation,0.8,For Hospital,W/ft2, -56,CS,Dining Area,0.9,General,W/ft2, -57,CS,Dining Area,1.3,For Penitentiary,W/ft2, -58,CS,Dining Area,1.3,For Hotel,W/ft2, -59,CS,Dining Area,1.2,For Motel,W/ft2, -60,CS,Dining Area,1.4,For Bar Lounge/Leisure Dining,W/ft2, -61,CS,Dining Area,2.1,For Family Dining,W/ft2, -62,CS,Food Preparation,1.2,General,W/ft2, -63,CS,Laboratory,1.4,General,W/ft2, -64,CS,Restrooms,0.9,General,W/ft2, -65,CS,Dressing/Locker/Fitting Room,0.6,General,W/ft2, -66,CS,Corridor/Transition,0.5,General,W/ft2, -67,CS,Corridor/Transition,1,For Hospital,W/ft2, -68,CS,Corridor/Transition,0.5,For Manufacturing Facility,W/ft2, -69,CS,Stairs: Active,0.6,General,W/ft2, -70,CS,Active Storage,0.8,General,W/ft2, -71,CS,Active Storage,0.9,For Hospital,W/ft2, -72,CS,Inactive Storage,0.3,General,W/ft2, -73,CS,Inactive Storage,0.8,For Museum,W/ft2, -74,CS,Electrical/Mechanical,1.5,General,W/ft2, -75,CS,Workshop,1.9,General,W/ft2, -76,SS,Gymnasium/Exercise Center,1.4,Playing Area,W/ft2, -77,SS,Gymnasium/Exercise Center,0.9,Exercise Area,W/ft2, -78,SS,Courthouse/Police Station/Penitentiary,1.9,Courtroom,W/ft2, -79,SS,Courthouse/Police Station/Penitentiary,0.9,Confinement Cells,W/ft2, -80,SS,Courthouse/Police Station/Penitentiary,1.3,Judges Chambers,W/ft2, -81,SS,Fire Stations,0.8,Fire Station Engine Room,W/ft2, -82,SS,Fire Stations,0.3,Sleeping Quarters,W/ft2, -83,SS,Post Office: Sorting Area,1.2,General,W/ft2, -84,SS,Convention Center: Exhibit Space,1.3,General,W/ft2, -85,SS,Library,1.1,Card File and Cataloging,W/ft2, -86,SS,Library,1.7,Stacks,W/ft2, -87,SS,Library,1.2,Reading Area,W/ft2, -88,SS,Hospital,2.7,Emergency,W/ft2, -89,SS,Hospital,0.8,Recovery,W/ft2, -90,SS,Hospital,1,Nurse Station,W/ft2, -91,SS,Hospital,1.5,Exam/Treatment,W/ft2, -92,SS,Hospital,1.2,Pharmacy,W/ft2, -93,SS,Hospital,0.7,Patient Room,W/ft2, -94,SS,Hospital,2.2,Operating Room,W/ft2, -95,SS,Hospital,0.6,Nursery,W/ft2, -96,SS,Hospital,1.4,Medical Supply,W/ft2, -97,SS,Hospital,0.9,Physical Therapy,W/ft2, -98,SS,Hospital,0.4,Radiology,W/ft2, -99,SS,Hospital,0.6,Laundry: Washing,W/ft2, -100,SS,Automotive: Service/Repair,0.7,General,W/ft2, -101,SS,Manufacturing,1.2,Low Bay (<25 ft Floor to Ceiling Height),W/ft2, -102,SS,Manufacturing,1.7,High Bay (>25 ft Floor to Ceiling Height),W/ft2, -103,SS,Manufacturing,2.1,Detailed Manufacturing,W/ft2, -104,SS,Manufacturing,1.2,Equipment Room,W/ft2, -105,SS,Manufacturing,0.5,Control Room,W/ft2, -106,SS,Hotel/Motel Guest Rooms,1.1,General,W/ft2, -107,SS,Dormitory: Living Quarters,1.1,General,W/ft2, -108,SS,Museum,1,General Exhibition,W/ft2, -109,SS,Museum,1.7,Restoration,W/ft2, -110,SS,Bank/Office: Banking Activity Area,1.5,General,W/ft2, -111,SS,Religious Buildings,2.4,"Worship Pulpit, Choir",W/ft2, -112,SS,Religious Buildings,0.9,Fellowship Hall,W/ft2, -113,SS,Retail,1.7,Sales Area,W/ft2, -114,SS,Retail,1.7,Mall Concourse,W/ft2, -115,SS,Sports Arena,2.7,Ring Sports Area,W/ft2, -116,SS,Sports Arena,2.3,Court Sports Area,W/ft2, -117,SS,Sports Arena,1.4,Indoor Playing Field Area,W/ft2, -118,SS,Warehouse,1.4,Fine Material Storage,W/ft2, -119,SS,Warehouse,0.9,Medium/Bulky Material Storage,W/ft2, -120,SS,Parking Garage: Garage Area,0.2,General,W/ft2, -121,SS,Transportation,0.6,Airport: Concourse,W/ft2, -122,SS,Transportation,1,Air/Train/Bus: Baggage Area,W/ft2, -123,SS,Transportation,1.5,Terminal: Ticket Counter,W/ft2, -124,SS,Retail,1.6,Sales Additional (Specific Display),W/ft2, -125,SS,Retail,3.9,Sales Additional (Valuable Merchandise),W/ft2, diff --git a/data/openstudio_standards_data/initial_data/level_3_lighting_90_1_2019.csv b/data/openstudio_standards_data/initial_data/level_3_lighting_90_1_2019.csv deleted file mode 100644 index fbc2b5ad09..0000000000 --- a/data/openstudio_standards_data/initial_data/level_3_lighting_90_1_2019.csv +++ /dev/null @@ -1,139 +0,0 @@ -id,method,lighting_primary_space_type,lighting_per_area,lighting_secondary_space_type,lighting_per_area_unit,annotation -1,BA,Automotive facility,0.75,General,W/ft2, -2,BA,Convention center,0.64,General,W/ft2, -3,BA,Courthouse,0.79,General,W/ft2, -4,BA,Dining: Bar lounge/leisure,0.8,General,W/ft2, -5,BA,Dining: Cafeteria/fast food,0.76,General,W/ft2, -6,BA,Dining: Family,0.71,General,W/ft2, -7,BA,Dormitory,0.53,General,W/ft2, -8,BA,Exercise center,0.72,General,W/ft2, -9,BA,Fire station,0.56,General,W/ft2, -10,BA,Gymnasium,0.76,General,W/ft2, -11,BA,Health-care clinic,0.81,General,W/ft2, -12,BA,Hospital,0.96,General,W/ft2, -13,BA,Hotel/motel,0.56,General,W/ft2, -14,BA,Library,0.83,General,W/ft2, -15,BA,Manufacturing facility,0.82,General,W/ft2, -16,BA,Motion picture theater,0.44,General,W/ft2, -17,BA,Multifamily,0.45,General,W/ft2, -18,BA,Museum,0.55,General,W/ft2, -19,BA,Office,0.64,General,W/ft2, -20,BA,Parking garage,0.18,General,W/ft2, -21,BA,Penitentiary,0.69,General,W/ft2, -22,BA,Performing arts theater,0.84,General,W/ft2, -23,BA,Police station,0.66,General,W/ft2, -24,BA,Post office,0.65,General,W/ft2, -25,BA,Religious facility,0.67,General,W/ft2, -26,BA,Retail,0.84,General,W/ft2, -27,BA,School/university,0.72,General,W/ft2, -28,BA,Sports arena,0.76,General,W/ft2, -29,BA,Town hall,0.69,General,W/ft2, -30,BA,Transportation,0.5,General,W/ft2, -31,BA,Warehouse,0.45,General,W/ft2, -32,BA,Workshop,0.91,General,W/ft2, -33,CS,Atrium,0.39,< 20 ft in height,W/ft2, -34,CS,Atrium,0.48,>= 20 ft and <= 40 ft in height,W/ft2, -35,CS,Atrium,0.6,> 40 ft in height,W/ft2, -36,CS,Audience Seating Area,0.61,Auditorium,W/ft2, -37,CS,Audience Seating Area,0.23,Gymnasium,W/ft2, -38,CS,Audience Seating Area,0.27,Motion picture theater,W/ft2, -39,CS,Audience Seating Area,0.67,Penitentiary,W/ft2, -40,CS,Audience Seating Area,1.16,Performing arts theater,W/ft2, -41,CS,Audience Seating Area,0.72,Religious facility,W/ft2, -42,CS,Audience Seating Area,0.33,Sports arena,W/ft2, -43,CS,Audience Seating Area,0.23,All other audience seating areas,W/ft2, -44,CS,Banking Activity Area,0.61,General,W/ft2, -45,CS,Breakroom,0.59,General,W/ft2,(See Lounge/Breakroom) -46,CS,Classroom/Lecture Hall/Training Room,0.89,Penitentiary,W/ft2, -47,CS,Classroom/Lecture Hall/Training Room,0.71,All other classrooms/lecture halls/training rooms,W/ft2, -48,CS,Conference/Meeting/Multipurpose Room,0.97,General,W/ft2, -49,CS,Confinement Cells,0.7,General,W/ft2, -50,CS,Copy/Print Room,0.31,General,W/ft2, -51,CS,Corridor,0.71,Facility for the visually impaired (and not used primarily by the staff),W/ft2, -52,CS,Corridor,0.71,Hospital,W/ft2, -53,CS,Corridor,0.41,All other corridors,W/ft2, -54,CS,Courtroom,1.2,General,W/ft2, -55,CS,Computer Room,0.94,General,W/ft2, -56,CS,Dining Area,0.42,Penitentiary,W/ft2, -57,CS,Dining Area,1.27,Facility for the visually impaired (and not used primarily by staff),W/ft2, -58,CS,Dining Area,0.86,Bar/lounge or leisure dining,W/ft2, -59,CS,Dining Area,0.4,Cafeteria or fast food dining,W/ft2, -60,CS,Dining Area,0.6,Family dining,W/ft2, -61,CS,Dining Area,0.43,All other dining areas,W/ft2, -62,CS,Electrical/Mechanical Room,0.43,General,W/ft2, -63,CS,Emergency Vehicle Garage,0.52,General,W/ft2, -64,CS,Food Preparation Area,1.09,General,W/ft2, -65,CS,Guest Room,0.41,General,W/ft2, -66,CS,Laboratory,1.11,In or as a classroom,W/ft2, -67,CS,Laboratory,1.33,All other laboratories,W/ft2, -68,CS,Laundry/Washing Area,0.53,General,W/ft2, -69,CS,"Loading Dock, Interior",0.88,General,W/ft2, -70,CS,Lobby,1.69,Facility for the visually impaired (and not used primarily by the staff),W/ft2, -71,CS,Lobby,0.65,Elevator,W/ft2, -72,CS,Lobby,0.51,Hotel,W/ft2, -73,CS,Lobby,0.23,Motion picture theater,W/ft2, -74,CS,Lobby,1.25,Performing arts theater ,W/ft2, -75,CS,Lobby,0.84,All other lobbies,W/ft2, -76,CS,Locker Room,0.52,General,W/ft2, -77,CS,Lounge/Breakroom,0.42,Healthcare facility,W/ft2, -78,CS,Lounge/Breakroom,0.59,All other lounges/breakrooms,W/ft2, -79,CS,Office,0.74,Enclosed and <= 250 ft2,W/ft2, -80,CS,Office,0.66,Enclosed and > 250 ft2,W/ft2, -81,CS,Office,0.61,Open plan,W/ft2, -82,CS,"Parking Area, Interior",0.15,General,W/ft2, -83,CS,Pharmacy Area,1.66,General,W/ft2, -84,CS,Restroom,1.26,Facility for the visually impaired (and not used primarily by the staff),W/ft2, -85,CS,Restroom,0.63,All other restrooms,W/ft2, -86,CS,Sales Area,1.05,General,W/ft2, -87,CS,"Seating Area, General",0.23,General,W/ft2, -88,CS,Stairway,0.49,General,W/ft2,The space containing the stairway shall determine the LPD and control requirements for the stairway. -89,CS,Stairwell,0.49,General,W/ft2, -90,CS,Storage Room,0.51,< 50 ft2,W/ft2, -91,CS,Storage Room,0.38,>= 50 ft2,W/ft2, -92,CS,Vehicular Maintenance Area,0.6,General,W/ft2, -93,CS,Workshop,1.26,General,W/ft2, -94,SS,Facility for the Visually Impaired,0.7,Chapel (used primarily by residents),W/ft2, -95,SS,Facility for the Visually Impaired,1.77,Recreation room/common living room (and not used primarily by staff),W/ft2, -96,SS,Automotive,0.6,General,W/ft2,(See 'Vehicular Maintenance Area') -97,SS,Convention Center: Exhibit Space,0.61,General,W/ft2, -98,SS,Dormitory: Living Quarters,0.5,General,W/ft2, -99,SS,Fire Station: Sleeping Quarters,0.23,General,W/ft2, -100,SS,Gymnasium/Fitness Center,0.9,Exercise area,W/ft2, -101,SS,Gymnasium/Fitness Center,0.85,Playing area,W/ft2, -102,SS,Healthcare Facility,1.4,Exam/treatment room,W/ft2, -103,SS,Healthcare Facility,0.94,Imaging room,W/ft2, -104,SS,Healthcare Facility,0.62,Medical supply room,W/ft2, -105,SS,Healthcare Facility,0.92,Nursery,W/ft2, -106,SS,Healthcare Facility,1.17,Nurse's station,W/ft2, -107,SS,Healthcare Facility,2.26,Operating room,W/ft2, -108,SS,Healthcare Facility,0.68,Patient room,W/ft2, -109,SS,Healthcare Facility,0.91,Physical therapy room,W/ft2, -110,SS,Healthcare Facility,1.25,Recovery room,W/ft2, -111,SS,Library,0.96,Reading area,W/ft2, -112,SS,Library,1.18,Stacks,W/ft2, -113,SS,Manufacturing Facility,0.8,Detailed manufacturing area,W/ft2, -114,SS,Manufacturing Facility,0.76,Equipment room,W/ft2, -115,SS,Manufacturing Facility,1.42,Extra high bay area (> 50 ft floor-to-ceiling height),W/ft2, -116,SS,Manufacturing Facility,1.24,High bay area (25 to 50 ft floor-to-ceiling height),W/ft2, -117,SS,Manufacturing Facility,0.86,Low bay area (< 25 ft floor-to-ceiling height),W/ft2, -118,SS,Museum,0.31,General exhibition area,W/ft2, -119,SS,Museum,1.1,Restoration room,W/ft2, -120,SS,Performing Arts Theater: Dressing Room,0.41,General,W/ft2, -121,SS,Post Office: Sorting Area,0.76,General,W/ft2, -122,SS,Religious Facility,0.54,Fellowship hall,W/ft2, -123,SS,Religious Facility,0.85,Worship/pulpit/choir area,W/ft2, -124,SS,Retail Facilities,0.51,Dressing/fitting room,W/ft2, -125,SS,Retail Facilities,0.82,Mall concourse,W/ft2, -126,SS,Sports Arena: Playing Area,2.94,Class I facility,W/ft2, -127,SS,Sports Arena: Playing Area,2.01,Class II facility,W/ft2, -128,SS,Sports Arena: Playing Area,1.3,Class III facility,W/ft2, -129,SS,Sports Arena: Playing Area,0.86,Class IV facility,W/ft2, -130,SS,Transportation Facility,0.39,Baggage/carousel area,W/ft2, -131,SS,Transportation Facility,0.25,Airport concourse,W/ft2, -132,SS,Transportation Facility,0.51,Ticket counter,W/ft2, -133,SS,Warehouse: Storage Area,0.33,"Medium to bulky, palletized items",W/ft2, -134,SS,Warehouse: Storage Area,0.69,"Smaller, hand-carried items",W/ft2, -135,SS,Retail,0.45,Sales Additional (Retail Area 1),W/ft2, -136,SS,Retail,0.45,Sales Additional (Retail Area 2),W/ft2, -137,SS,Retail,1.05,Sales Additional (Retail Area 3),W/ft2, -138,SS,Retail,1.88,Sales Additional (Retail Area 4),W/ft2, diff --git a/data/openstudio_standards_data/initial_data/level_3_ventilation_62_1_2004.csv b/data/openstudio_standards_data/initial_data/level_3_ventilation_62_1_2004.csv deleted file mode 100644 index 90bd0aa856..0000000000 --- a/data/openstudio_standards_data/initial_data/level_3_ventilation_62_1_2004.csv +++ /dev/null @@ -1,64 +0,0 @@ -id,ventilation_primary_space_type,ventilation_secondary_space_type,ventilation_per_person,ventilation_per_person_unit,ventilation_per_area,ventilation_per_area_unit,occupancy_per_area,occupancy_per_area_unit,air_class,os,annotation -1,Correctional Facilities,Cell,5,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, -2,Correctional Facilities,Day room,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, -3,Correctional Facilities,Guard stations,5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,, -4,Correctional Facilities,Booking/waiting,7.5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,2,, -5,Educational Facilities,Daycare (through age 4),10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, -6,Educational Facilities,Classrooms (ages 5-8),10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, -7,Educational Facilities,Classrooms (age 9 plus),10,cfm/person,0.12,cfm/ft2,35,ppl/1000 ft2,1,, -8,Educational Facilities,Lecture classroom,7.5,cfm/person,0.06,cfm/ft2,65,ppl/1000 ft2,1,, -9,Educational Facilities,Lecture hall (fixed seats),7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -10,Educational Facilities,Art classroom,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, -11,Educational Facilities,Science laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,,, -12,Educational Facilities,Wood/metal shop,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, -13,Educational Facilities,Computer lab,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, -14,Educational Facilities,Media center,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, -15,Educational Facilities,Music/theater/dance,10,cfm/person,0.06,cfm/ft2,35,ppl/1000 ft2,1,, -16,Educational Facilities,Multi-use assembly,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, -17,Food and Beverage Service,Restaurant dining rooms,7.5,cfm/person,0.18,cfm/ft2,70,ppl/1000 ft2,2,, -18,Food and Beverage Service,Cafeteria/fast food dining,7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, -19,Food and Beverage Service,"Bars, cocktail lounges",7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, -20,General,Conference/meeting,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, -21,General,Corridors,,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,1,, -22,General,Storage rooms,,cfm/person,0.12,cfm/ft2,,ppl/1000 ft2,1,, -23,"Hotels, Motels, Resorts, Dormitories",Bedroom/living Room,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,, -24,"Hotels, Motels, Resorts, Dormitories",Barracks sleeping areas,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, -25,"Hotels, Motels, Resorts, Dormitories",Lobbies/prefunction,7.5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, -26,"Hotels, Motels, Resorts, Dormitories",Multi-purpose assembly,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,, -27,Office Buildings,Office space,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1,, -28,Office Buildings,Reception areas,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, -29,Office Buildings,Telephone/data entry,5,cfm/person,0.06,cfm/ft2,60,ppl/1000 ft2,1,, -30,Office Buildings,Main entry lobbies,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,, -31,Miscellaneous Spaces,Bank vaults/safe deposit,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,2,, -32,Miscellaneous Spaces,Computer (not printing),5,cfm/person,0.06,cfm/ft2,4,ppl/1000 ft2,1,, -33,Miscellaneous Spaces,Pharmacy (prep. area),5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, -34,Miscellaneous Spaces,Photo studios,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, -35,Miscellaneous Spaces,Shipping/receiving,,cfm/person,0.12,cfm/ft2,,ppl/1000 ft2,1,, -36,Miscellaneous Spaces,Transportation waiting,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, -37,Miscellaneous Spaces,Warehouses,,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,2,, -38,Public Assembly Spaces,Auditorium seating area,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -39,Public Assembly Spaces,Places of religious workshop,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,, -40,Public Assembly Spaces,Courtrooms,5,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, -41,Public Assembly Spaces,Legislative chambers,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, -42,Public Assembly Spaces,Libraries,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, -43,Public Assembly Spaces,Lobbies,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -44,Public Assembly Spaces,Museums (children's),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, -45,Public Assembly Spaces,Museums/galleries,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, -46,Retail,Sales (except as below),7.5,cfm/person,0.12,cfm/ft2,15,ppl/1000 ft2,2,, -47,Retail,Mall common areas,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, -48,Retail,Barber shop,7.5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,2,, -49,Retail,Beauty and nail salons,20,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, -50,Retail,Pet shops (animal areas),7.5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, -51,Retail,Supermarket,7.5,cfm/person,0.06,cfm/ft2,8,ppl/1000 ft2,1,, -52,Retail,Coin-operated laundries,7.5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,2,, -53,Sports and Entertainment,Sports arena (play area),,cfm/person,0.3,cfm/ft2,,ppl/1000 ft2,1,, -54,Sports and Entertainment,"Gym, stadium (play area)",,cfm/person,0.3,cfm/ft2,30,ppl/1000 ft2,2,, -55,Sports and Entertainment,Spectator areas,7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -56,Sports and Entertainment,Swimming (pool & deck),,cfm/person,0.48,cfm/ft2,,ppl/1000 ft2,2,, -57,Sports and Entertainment,Disco/dance floors,20,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, -58,Sports and Entertainment,Health club/aerobics room,20,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,2,, -59,Sports and Entertainment,Health club/weight rooms,20,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,2,, -60,Sports and Entertainment,Bowling alley (seating),10,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, -61,Sports and Entertainment,Gambling casinos,7.5,cfm/person,0.18,cfm/ft2,120,ppl/1000 ft2,1,, -62,Sports and Entertainment,Game arcades,7.5,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, -63,Sports and Entertainment,"Stages, studios",10,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, diff --git a/data/openstudio_standards_data/initial_data/level_3_ventilation_62_1_2019.csv b/data/openstudio_standards_data/initial_data/level_3_ventilation_62_1_2019.csv deleted file mode 100644 index 0ebaf45414..0000000000 --- a/data/openstudio_standards_data/initial_data/level_3_ventilation_62_1_2019.csv +++ /dev/null @@ -1,110 +0,0 @@ -id,ventilation_primary_space_type,ventilation_secondary_space_type,ventilation_per_person,ventilation_per_person_unit,ventilation_per_area,ventilation_per_area_unit,occupancy_per_area,occupancy_per_area_unit,air_class,os,annotation -1,Animal Facilities,Animal exam room (veterinary office),10,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2,, -2,Animal Facilities,Animal imaging (MRI/CT/PET),10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, -3,Animal Facilities,Animal operating rooms,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, -4,Animal Facilities,Animal postoperative recovery room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, -5,Animal Facilities,Animal preparation rooms,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, -6,Animal Facilities,Animal procedure room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, -7,Animal Facilities,Animal surgery scrub,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, -8,Animal Facilities,Large-animal holding room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, -9,Animal Facilities,Necropsy,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, -10,Animal Facilities,Small-animal-cage room (static cages),10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, -11,Animal Facilities,Small-animal-cage room (ventilated cages),10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, -12,Correctional Facilities,Booking/waiting,7.5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,2,, -13,Correctional Facilities,Cell,5,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, -14,Correctional Facilities,Dayroom,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, -15,Correctional Facilities,Guard stations,5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,, -16,Educational Facilities,Art classroom,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, -17,Educational Facilities,Classrooms (ages 5 to 8),10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, -18,Educational Facilities,Classrooms (age 9 plus),10,cfm/person,0.12,cfm/ft2,35,ppl/1000 ft2,1,, -19,Educational Facilities,Computer lab,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, -20,Educational Facilities,Daycare sickroom,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,3,, -21,Educational Facilities,Daycare (through age 4),10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, -22,Educational Facilities,Lecture classroom,7.5,cfm/person,0.06,cfm/ft2,65,ppl/1000 ft2,1,yes, -23,Educational Facilities,Lecture hall (fixed seats),7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,yes, -24,Educational Facilities,Libraries (education),5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,,, -25,Educational Facilities,Media center,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, -26,Educational Facilities,Multiuse assembly,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,yes, -27,Educational Facilities,Music/theater/dance,10,cfm/person,0.06,cfm/ft2,35,ppl/1000 ft2,1,yes, -28,Educational Facilities,Science laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, -29,Educational Facilities,University/college laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, -30,Educational Facilities,Wood/metal shop,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, -31,Food and Beverage Service,"Bars, cocktail lounges",7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, -32,Food and Beverage Service,Cafeteria/fast-food dining,7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, -33,Food and Beverage Service,Kitchen (cooking),7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2,, -34,Food and Beverage Service,Restaurant dining rooms,7.5,cfm/person,0.18,cfm/ft2,70,ppl/1000 ft2,2,, -35,"Food and Beverage Service, General",Break rooms,5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,1,yes, -36,"Food and Beverage Service, General",Coffee stations,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,yes, -37,"Food and Beverage Service, General",Conference/meeting,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,yes, -38,"Food and Beverage Service, General",Corridors,,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,1,yes, -39,"Food and Beverage Service, General",Occupiable storage rooms for liquids or gels,5,cfm/person,0.12,cfm/ft2,2,ppl/1000 ft2,2,, -40,"Hotels, Motels, Resorts, Dormitories",Barracks sleeping areas,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,yes, -41,"Hotels, Motels, Resorts, Dormitories",Bedroom/living room,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,yes, -42,"Hotels, Motels, Resorts, Dormitories","Laundry rooms, central",5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,2,, -43,"Hotels, Motels, Resorts, Dormitories",Laundry rooms within dwelling units,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, -44,"Hotels, Motels, Resorts, Dormitories",Lobbies/prefunction,7.5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,yes, -45,"Hotels, Motels, Resorts, Dormitories",Multipurpose assembly,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,yes, -46,Miscellaneous Spaces,Banks or bank lobbies,7.5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,yes, -47,Miscellaneous Spaces,Bank vaults/safe deposit,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,2,yes, -48,Miscellaneous Spaces,Computer (not printing),5,cfm/person,0.06,cfm/ft2,4,ppl/1000 ft2,1,yes, -49,Miscellaneous Spaces,Freezer and refrigerated spaces (<50�F [10�C]),10,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,2,, -50,Miscellaneous Spaces,Manufacturing where hazardous materials are not used,10,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,2,, -51,Miscellaneous Spaces,Manufacturing where hazardous materials are used (excludes heavy industrial and chemical processes),10,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,3,, -52,Miscellaneous Spaces,Pharmacy (prep. area),5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, -53,Miscellaneous Spaces,Photo studios,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, -54,Miscellaneous Spaces,Shipping/receiving,10,cfm/person,0.12,cfm/ft2,2,ppl/1000 ft2,2,, -55,Miscellaneous Spaces,"Sorting, packing, light assembly",7.5,cfm/person,0.12,cfm/ft2,7,ppl/1000 ft2,2,, -56,Miscellaneous Spaces,Telephone closets,,cfm/person,0,cfm/ft2,,ppl/1000 ft2,1,, -57,Miscellaneous Spaces,Transportation waiting,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,yes, -58,Miscellaneous Spaces,Warehouses,10,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,2,, -59,Office Buildings,Breakrooms,5,cfm/person,0.12,cfm/ft2,50,ppl/1000 ft2,1,, -60,Office Buildings,Main entry lobbies,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,yes, -61,Office Buildings,Occupiable storage rooms for dry materials,5,cfm/person,0.06,cfm/ft2,2,ppl/1000 ft2,1,, -62,Office Buildings,Office space,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1,yes, -63,Office Buildings,Reception areas,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,yes, -64,Office Buildings,Telephone/data entry,5,cfm/person,0.06,cfm/ft2,60,ppl/1000 ft2,1,yes, -65,Outpatient Health Care Facilities,Birthing room,10,cfm/person,0.18,cfm/ft2,15,ppl/1000 ft2,2,, -66,Outpatient Health Care Facilities,Class 1 imaging rooms,5,cfm/person,0.12,cfm/ft2,5,ppl/1000 ft2,1,, -67,Outpatient Health Care Facilities,Dental operatory,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, -68,Outpatient Health Care Facilities,General examination room,7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,1,, -69,Outpatient Health Care Facilities,Other dental treatment areas,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1,, -70,Outpatient Health Care Facilities,Physical therapy exercise area,20,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,2,, -71,Outpatient Health Care Facilities,Physical therapy individual room,10,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, -72,Outpatient Health Care Facilities,Physical therapeutic pool area,,cfm/person,0.48,cfm/ft2,,ppl/1000 ft2,2,, -73,Outpatient Health Care Facilities,Prosthetics and orthotics room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, -74,Outpatient Health Care Facilities,Psychiatric consultation room,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, -75,Outpatient Health Care Facilities,Psychiatric examination room,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, -76,Outpatient Health Care Facilities,Psychiatric group room,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, -77,Outpatient Health Care Facilities,Psychiatric seclusion room,10,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1,, -78,Outpatient Health Care Facilities,Speech therapy room,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, -79,Outpatient Health Care Facilities,Urgent care examination room,7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,1,, -80,Outpatient Health Care Facilities,Urgent care observation room,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, -81,Outpatient Health Care Facilities,Urgent care treatment room,7.5,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, -82,Outpatient Health Care Facilities,Urgent care triage room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, -83,Public Assembly Spaces,Auditorium seating area,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,yes, -84,Public Assembly Spaces,Courtrooms,5,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,yes, -85,Public Assembly Spaces,Legislative chambers,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,yes, -86,Public Assembly Spaces,Libraries (public assembly),5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, -87,Public Assembly Spaces,Lobbies,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,yes, -88,Public Assembly Spaces,Museums (children's),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, -89,Public Assembly Spaces,Museums/galleries,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,yes, -90,Public Assembly Spaces,Places of religious worship,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,yes, -91,Retail,Sales (except as below),7.5,cfm/person,0.12,cfm/ft2,15,ppl/1000 ft2,2,, -92,Retail,Barbershop,7.5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,2,yes, -93,Retail,Beauty and nail salons,20,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, -94,Retail,Coin-operated laundries,7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2,, -95,Retail,Mall common areas,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,yes, -96,Retail,Pet shops (animal areas),7.5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, -97,Retail,Supermarket,7.5,cfm/person,0.06,cfm/ft2,8,ppl/1000 ft2,1,yes, -98,Sports and Entertainment,Bowling alley (seating),10,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, -99,Sports and Entertainment,Disco/dance floors,20,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,2,yes, -100,Sports and Entertainment,Gambling casinos,7.5,cfm/person,0.18,cfm/ft2,120,ppl/1000 ft2,1,, -101,Sports and Entertainment,Game arcades,7.5,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, -102,Sports and Entertainment,"Gym, sports arena (play area)",20,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,2,, -103,Sports and Entertainment,Health club/aerobics room,20,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,2,, -104,Sports and Entertainment,Health club/weight rooms,20,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,2,, -105,Sports and Entertainment,Spectator areas,7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,yes, -106,Sports and Entertainment,"Stages, studios",10,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,yes, -107,Sports and Entertainment,Swimming (pool and deck),,cfm/person,0.48,cfm/ft2,,ppl/1000 ft2,2,, -108,Transient Residential,Common corridors,,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,1,yes, -109,Transient Residential,Dwelling unit,5,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,1,yes, diff --git a/data/openstudio_standards_data/initial_data/light_subspaces.json b/data/openstudio_standards_data/initial_data/light_subspaces.json deleted file mode 100644 index 5532c03ca0..0000000000 --- a/data/openstudio_standards_data/initial_data/light_subspaces.json +++ /dev/null @@ -1,1718 +0,0 @@ -[ - { - "id": 1, - "lighting_type_name": "bam_automotive_facility", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 1 - }, - { - "id": 2, - "lighting_type_name": "bam_convention_center", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 2 - }, - { - "id": 3, - "lighting_type_name": "bam_courthouse", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 3 - }, - { - "id": 4, - "lighting_type_name": "bam_dinin_bar_lounge_leisure", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 4 - }, - { - "id": 5, - "lighting_type_name": "bam_dining_cafeteria_fast_food", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 5 - }, - { - "id": 6, - "lighting_type_name": "bam_dining_family", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 6 - }, - { - "id": 7, - "lighting_type_name": "bam_dormitory", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 7 - }, - { - "id": 8, - "lighting_type_name": "bam_exercise_center", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 8 - }, - { - "id": 9, - "lighting_type_name": "bam_fire_station", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 23 - }, - { - "id": 10, - "lighting_type_name": "bam_gymnasium", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 9 - }, - { - "id": 11, - "lighting_type_name": "bam_healthcare_clinic", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 10 - }, - { - "id": 12, - "lighting_type_name": "bam_hospital", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 11 - }, - { - "id": 13, - "lighting_type_name": "bam_hotel", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 12 - }, - { - "id": 14, - "lighting_type_name": "bam_library", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 13 - }, - { - "id": 15, - "lighting_type_name": "bam_manufacturing_facility", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 14 - }, - { - "id": 16, - "lighting_type_name": "bam_motel", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 15 - }, - { - "id": 17, - "lighting_type_name": "bam_motion_picture_theater", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 16 - }, - { - "id": 18, - "lighting_type_name": "bam_multifamily", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 17 - }, - { - "id": 19, - "lighting_type_name": "bam_museum", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 18 - }, - { - "id": 20, - "lighting_type_name": "bam_office", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 19 - }, - { - "id": 21, - "lighting_type_name": "bam_parking_garage", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 20 - }, - { - "id": 22, - "lighting_type_name": "bam_penitentiary", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 21 - }, - { - "id": 23, - "lighting_type_name": "bam_performing_arts_theater", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 22 - }, - { - "id": 24, - "lighting_type_name": "bam_police_station", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 23 - }, - { - "id": 25, - "lighting_type_name": "bam_post_office", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 24 - }, - { - "id": 26, - "lighting_type_name": "bam_religious_facility", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 25 - }, - { - "id": 27, - "lighting_type_name": "bam_retail", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 26 - }, - { - "id": 28, - "lighting_type_name": "bam_school_university", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 27 - }, - { - "id": 29, - "lighting_type_name": "bam_sports_arena", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 28 - }, - { - "id": 30, - "lighting_type_name": "bam_town_hall", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 29 - }, - { - "id": 31, - "lighting_type_name": "bam_transportation", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 30 - }, - { - "id": 32, - "lighting_type_name": "bam_warehouse", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 31 - }, - { - "id": 33, - "lighting_type_name": "bam_workshop", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 32 - }, - { - "id": 34, - "lighting_type_name": "office_enclosed_small", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 33 - }, - { - "id": 35, - "lighting_type_name": "office_enclosed_large", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 33 - }, - { - "id": 36, - "lighting_type_name": "office_open", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 34 - }, - { - "id": 37, - "lighting_type_name": "conference_meeting_multipurpose", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 35 - }, - { - "id": 38, - "lighting_type_name": "classroom_lecture_training_general", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 36 - }, - { - "id": 39, - "lighting_type_name": "classroom_lecture_training_penitentiary", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 37 - }, - { - "id": 40, - "lighting_type_name": "lobby_general", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 38 - }, - { - "id": 41, - "lighting_type_name": "lobby_hotel", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 39 - }, - { - "id": 42, - "lighting_type_name": "lobby_performing_arts_theater", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 40 - }, - { - "id": 43, - "lighting_type_name": "lobby_motion_picture_theater", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 41 - }, - { - "id": 44, - "lighting_type_name": "lobby_visually_impaired", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 38 - }, - { - "id": 45, - "lighting_type_name": "lobby_elevator", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 38 - }, - { - "id": 46, - "lighting_type_name": "audience_seating_general", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 42 - }, - { - "id": 47, - "lighting_type_name": "audience_seating_gymnasium", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 43 - }, - { - "id": 48, - "lighting_type_name": "audience_seating_exercise_center", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 44 - }, - { - "id": 49, - "lighting_type_name": "audience_seating_convention_center", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 45 - }, - { - "id": 50, - "lighting_type_name": "audience_seating_penitentiary", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 46 - }, - { - "id": 51, - "lighting_type_name": "audience_seating_religious_facility", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 47 - }, - { - "id": 52, - "lighting_type_name": "audience_seating_sports_arena", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 48 - }, - { - "id": 53, - "lighting_type_name": "audience_seating_performing_arts_theater", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 49 - }, - { - "id": 54, - "lighting_type_name": "audience_seating_motion_picture_theater", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 50 - }, - { - "id": 55, - "lighting_type_name": "audience_seating_transportation", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 51 - }, - { - "id": 56, - "lighting_type_name": "audience_seating_auditorium", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 42 - }, - { - "id": 57, - "lighting_type_name": "atrium_first_three_floor", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 52 - }, - { - "id": 58, - "lighting_type_name": "atrium_each_additional_floor", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 53 - }, - { - "id": 59, - "lighting_type_name": "lounge_breakroom_general", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 54 - }, - { - "id": 60, - "lighting_type_name": "lounge_breakroom_healthcare_facility", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 55 - }, - { - "id": 61, - "lighting_type_name": "dining_general", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 56 - }, - { - "id": 62, - "lighting_type_name": "dining_penitentiary", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 57 - }, - { - "id": 63, - "lighting_type_name": "dining_hotel", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 58 - }, - { - "id": 64, - "lighting_type_name": "dining_motel", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 59 - }, - { - "id": 65, - "lighting_type_name": "dining_bar_lounge_leisure", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 60 - }, - { - "id": 66, - "lighting_type_name": "dining_family", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 61 - }, - { - "id": 67, - "lighting_type_name": "dining_cafeteria_fast_food", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 56 - }, - { - "id": 68, - "lighting_type_name": "dining_visually_impaired", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 56 - }, - { - "id": 69, - "lighting_type_name": "kitchen", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 62 - }, - { - "id": 70, - "lighting_type_name": "laboratory_classroom", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 63 - }, - { - "id": 71, - "lighting_type_name": "laboratory_all_other", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 63 - }, - { - "id": 72, - "lighting_type_name": "restroom_visually_impaired", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 64 - }, - { - "id": 73, - "lighting_type_name": "restroom_all_other", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 64 - }, - { - "id": 74, - "lighting_type_name": "performing_arts_dressing_room", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 65 - }, - { - "id": 75, - "lighting_type_name": "corridor_general", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 66 - }, - { - "id": 76, - "lighting_type_name": "corridor_hospital", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 67 - }, - { - "id": 77, - "lighting_type_name": "corridor_manufacturing_facility", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 68 - }, - { - "id": 78, - "lighting_type_name": "corridor_visually_impaired", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 66 - }, - { - "id": 79, - "lighting_type_name": "stairway", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 69 - }, - { - "id": 80, - "lighting_type_name": "stairwell", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 69 - }, - { - "id": 81, - "lighting_type_name": "storage_ all_other_small", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 70 - }, - { - "id": 82, - "lighting_type_name": "storage_ all_other_large", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 70 - }, - { - "id": 83, - "lighting_type_name": "storage_hospital_small", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 71 - }, - { - "id": 84, - "lighting_type_name": "storage_hospital_large", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 71 - }, - { - "id": 85, - "lighting_type_name": "storage_inactive", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 72 - }, - { - "id": 86, - "lighting_type_name": "storage_inactive_museum", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 73 - }, - { - "id": 87, - "lighting_type_name": "electrical_mechanical", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 74 - }, - { - "id": 88, - "lighting_type_name": "workshop", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 75 - }, - { - "id": 89, - "lighting_type_name": "gymnasium_playing_area", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 76 - }, - { - "id": 90, - "lighting_type_name": "gymnasium_exercise_area", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 77 - }, - { - "id": 91, - "lighting_type_name": "courtroom", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 78 - }, - { - "id": 92, - "lighting_type_name": "confinement_cells", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 79 - }, - { - "id": 93, - "lighting_type_name": "judges_chambers", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 80 - }, - { - "id": 94, - "lighting_type_name": "emergency_vehicle_garage", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 81 - }, - { - "id": 95, - "lighting_type_name": "firestation_sleeping_quarters", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 82 - }, - { - "id": 96, - "lighting_type_name": "post_office_sorting_area", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 83 - }, - { - "id": 97, - "lighting_type_name": "exhibit_convention_center", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 84 - }, - { - "id": 98, - "lighting_type_name": "library_cataloging", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 85 - }, - { - "id": 99, - "lighting_type_name": "library_stacks", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 86 - }, - { - "id": 100, - "lighting_type_name": "library_reading", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 87 - }, - { - "id": 101, - "lighting_type_name": "emergency_room", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 88 - }, - { - "id": 102, - "lighting_type_name": "recovery", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 89 - }, - { - "id": 103, - "lighting_type_name": "nurses_station", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 90 - }, - { - "id": 104, - "lighting_type_name": "exam_treatment", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 91 - }, - { - "id": 105, - "lighting_type_name": "pharmacy", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 92 - }, - { - "id": 106, - "lighting_type_name": "patient_room", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 93 - }, - { - "id": 107, - "lighting_type_name": "operating_room", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 94 - }, - { - "id": 108, - "lighting_type_name": "nursery", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 95 - }, - { - "id": 109, - "lighting_type_name": "medical_supply", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 96 - }, - { - "id": 110, - "lighting_type_name": "physical_therapy", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 97 - }, - { - "id": 111, - "lighting_type_name": "imaging", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 98 - }, - { - "id": 112, - "lighting_type_name": "laundry_washing", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 99 - }, - { - "id": 113, - "lighting_type_name": "automotive", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 100 - }, - { - "id": 114, - "lighting_type_name": "manufacturing_low_bay", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 101 - }, - { - "id": 115, - "lighting_type_name": "manufacturing_high_bay", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 102 - }, - { - "id": 116, - "lighting_type_name": "detailed_manufacuring", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 103 - }, - { - "id": 117, - "lighting_type_name": "manufacturing_equipment_room", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 104 - }, - { - "id": 118, - "lighting_type_name": "manufacturing_control", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 105 - }, - { - "id": 119, - "lighting_type_name": "guest_room", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 106 - }, - { - "id": 120, - "lighting_type_name": "dormitory_living_quarters", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 107 - }, - { - "id": 121, - "lighting_type_name": "museum_exhibit_area", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 108 - }, - { - "id": 122, - "lighting_type_name": "museum_restoration", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 109 - }, - { - "id": 123, - "lighting_type_name": "banking_activity", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 110 - }, - { - "id": 124, - "lighting_type_name": "worship_pulpit_choir_area", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 111 - }, - { - "id": 125, - "lighting_type_name": "fellowship_hall_religious_facility", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 112 - }, - { - "id": 126, - "lighting_type_name": "sales", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 113 - }, - { - "id": 127, - "lighting_type_name": "retail_mall_concourse", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 114 - }, - { - "id": 128, - "lighting_type_name": "sports_arena_ring_sports_area", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 115 - }, - { - "id": 129, - "lighting_type_name": "sports_arena_court_sports_area", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 116 - }, - { - "id": 130, - "lighting_type_name": "sports_arena_indoor_playing_field", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 117 - }, - { - "id": 131, - "lighting_type_name": "warehouse_bulk_storage", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 119 - }, - { - "id": 132, - "lighting_type_name": "parking_area_interior", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 120 - }, - { - "id": 133, - "lighting_type_name": "airport_concourse", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 121 - }, - { - "id": 134, - "lighting_type_name": "baggage_carousel", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 122 - }, - { - "id": 135, - "lighting_type_name": "transportation_ticket_counter", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 123 - }, - { - "id": 136, - "lighting_type_name": "sales_display_type_1", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 124 - }, - { - "id": 137, - "lighting_type_name": "sales_display_type_2", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 124 - }, - { - "id": 138, - "lighting_type_name": "sales_display_type_3", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 125 - }, - { - "id": 139, - "lighting_type_name": "sales_display_type_4", - "lighting_table": "light_def_90_1_2004", - "lpd_901_id": 125 - }, - { - "id": 140, - "lighting_type_name": "bam_automotive_facility", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 1 - }, - { - "id": 141, - "lighting_type_name": "bam_convention_center", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 2 - }, - { - "id": 142, - "lighting_type_name": "bam_courthouse", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 3 - }, - { - "id": 143, - "lighting_type_name": "bam_dinin_bar_lounge_leisure", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 4 - }, - { - "id": 144, - "lighting_type_name": "bam_dining_cafeteria_fast_food", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 5 - }, - { - "id": 145, - "lighting_type_name": "bam_dining_family", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 6 - }, - { - "id": 146, - "lighting_type_name": "bam_dormitory", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 7 - }, - { - "id": 147, - "lighting_type_name": "bam_exercise_center", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 8 - }, - { - "id": 148, - "lighting_type_name": "bam_fire_station", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 9 - }, - { - "id": 149, - "lighting_type_name": "bam_gymnasium", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 10 - }, - { - "id": 150, - "lighting_type_name": "bam_healthcare_clinic", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 11 - }, - { - "id": 151, - "lighting_type_name": "bam_hospital", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 12 - }, - { - "id": 152, - "lighting_type_name": "bam_hotel", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 13 - }, - { - "id": 153, - "lighting_type_name": "bam_library", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 14 - }, - { - "id": 154, - "lighting_type_name": "bam_manufacturing_facility", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 15 - }, - { - "id": 155, - "lighting_type_name": "bam_motel", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 13 - }, - { - "id": 156, - "lighting_type_name": "bam_motion_picture_theater", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 16 - }, - { - "id": 157, - "lighting_type_name": "bam_multifamily", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 17 - }, - { - "id": 158, - "lighting_type_name": "bam_museum", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 18 - }, - { - "id": 159, - "lighting_type_name": "bam_office", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 19 - }, - { - "id": 160, - "lighting_type_name": "bam_parking_garage", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 20 - }, - { - "id": 161, - "lighting_type_name": "bam_penitentiary", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 21 - }, - { - "id": 162, - "lighting_type_name": "bam_performing_arts_theater", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 22 - }, - { - "id": 163, - "lighting_type_name": "bam_police_station", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 23 - }, - { - "id": 164, - "lighting_type_name": "bam_post_office", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 24 - }, - { - "id": 165, - "lighting_type_name": "bam_religious_facility", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 25 - }, - { - "id": 166, - "lighting_type_name": "bam_retail", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 26 - }, - { - "id": 167, - "lighting_type_name": "bam_school_university", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 27 - }, - { - "id": 168, - "lighting_type_name": "bam_sports_arena", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 28 - }, - { - "id": 169, - "lighting_type_name": "bam_town_hall", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 29 - }, - { - "id": 170, - "lighting_type_name": "bam_transportation", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 30 - }, - { - "id": 171, - "lighting_type_name": "bam_warehouse", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 31 - }, - { - "id": 172, - "lighting_type_name": "bam_workshop", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 32 - }, - { - "id": 173, - "lighting_type_name": "office_enclosed_small", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 79 - }, - { - "id": 174, - "lighting_type_name": "office_enclosed_large", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 80 - }, - { - "id": 175, - "lighting_type_name": "office_open", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 81 - }, - { - "id": 176, - "lighting_type_name": "conference_meeting_multipurpose", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 48 - }, - { - "id": 177, - "lighting_type_name": "classroom_lecture_training_general", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 47 - }, - { - "id": 178, - "lighting_type_name": "classroom_lecture_training_penitentiary", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 46 - }, - { - "id": 179, - "lighting_type_name": "lobby_general", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 75 - }, - { - "id": 180, - "lighting_type_name": "lobby_hotel", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 72 - }, - { - "id": 181, - "lighting_type_name": "lobby_performing_arts_theater", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 74 - }, - { - "id": 182, - "lighting_type_name": "lobby_motion_picture_theater", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 73 - }, - { - "id": 183, - "lighting_type_name": "lobby_visually_impaired", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 70 - }, - { - "id": 184, - "lighting_type_name": "lobby_elevator", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 71 - }, - { - "id": 185, - "lighting_type_name": "audience_seating_general", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 43 - }, - { - "id": 186, - "lighting_type_name": "audience_seating_gymnasium", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 37 - }, - { - "id": 187, - "lighting_type_name": "audience_seating_exercise_center", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 43 - }, - { - "id": 188, - "lighting_type_name": "audience_seating_convention_center", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 43 - }, - { - "id": 189, - "lighting_type_name": "audience_seating_penitentiary", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 39 - }, - { - "id": 190, - "lighting_type_name": "audience_seating_religious_facility", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 41 - }, - { - "id": 191, - "lighting_type_name": "audience_seating_sports_arena", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 42 - }, - { - "id": 192, - "lighting_type_name": "audience_seating_performing_arts_theater", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 40 - }, - { - "id": 193, - "lighting_type_name": "audience_seating_motion_picture_theater", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 38 - }, - { - "id": 194, - "lighting_type_name": "audience_seating_transportation", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 43 - }, - { - "id": 195, - "lighting_type_name": "audience_seating_auditorium", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 36 - }, - { - "id": 196, - "lighting_type_name": "atrium_low", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 33 - }, - { - "id": 197, - "lighting_type_name": "atrium_medium", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 34 - }, - { - "id": 198, - "lighting_type_name": "atrium_high", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 35 - }, - { - "id": 199, - "lighting_type_name": "lounge_breakroom_general", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 78 - }, - { - "id": 200, - "lighting_type_name": "lounge_breakroom_healthcare_facility", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 77 - }, - { - "id": 201, - "lighting_type_name": "dining_general", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 61 - }, - { - "id": 202, - "lighting_type_name": "dining_penitentiary", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 56 - }, - { - "id": 203, - "lighting_type_name": "dining_hotel", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 61 - }, - { - "id": 204, - "lighting_type_name": "dining_motel", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 61 - }, - { - "id": 205, - "lighting_type_name": "dining_bar_lounge_leisure", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 58 - }, - { - "id": 206, - "lighting_type_name": "dining_family", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 60 - }, - { - "id": 207, - "lighting_type_name": "dining_cafeteria_fast_food", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 59 - }, - { - "id": 208, - "lighting_type_name": "dining_visually_impaired", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 57 - }, - { - "id": 209, - "lighting_type_name": "kitchen", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 64 - }, - { - "id": 210, - "lighting_type_name": "laboratory_classroom", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 66 - }, - { - "id": 211, - "lighting_type_name": "laboratory_all_other", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 67 - }, - { - "id": 212, - "lighting_type_name": "restroom_visually_impaired", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 84 - }, - { - "id": 213, - "lighting_type_name": "restroom_all_other", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 85 - }, - { - "id": 214, - "lighting_type_name": "performing_arts_dressing_room", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 120 - }, - { - "id": 215, - "lighting_type_name": "corridor_general", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 53 - }, - { - "id": 216, - "lighting_type_name": "corridor_hospital", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 52 - }, - { - "id": 217, - "lighting_type_name": "corridor_manufacturing_facility", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 53 - }, - { - "id": 218, - "lighting_type_name": "corridor_visually_impaired", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 51 - }, - { - "id": 219, - "lighting_type_name": "stairway", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 88 - }, - { - "id": 220, - "lighting_type_name": "stairwell", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 89 - }, - { - "id": 221, - "lighting_type_name": "storage_ all_other_small", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 90 - }, - { - "id": 222, - "lighting_type_name": "storage_ all_other_large", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 91 - }, - { - "id": 223, - "lighting_type_name": "storage_hospital_small", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 90 - }, - { - "id": 224, - "lighting_type_name": "storage_hospital_large", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 91 - }, - { - "id": 225, - "lighting_type_name": "electrical_mechanical", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 62 - }, - { - "id": 226, - "lighting_type_name": "workshop", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 93 - }, - { - "id": 227, - "lighting_type_name": "gymnasium_playing_area", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 101 - }, - { - "id": 228, - "lighting_type_name": "gymnasium_exercise_area", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 100 - }, - { - "id": 229, - "lighting_type_name": "courtroom", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 54 - }, - { - "id": 230, - "lighting_type_name": "confinement_cells", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 49 - }, - { - "id": 231, - "lighting_type_name": "emergency_vehicle_garage", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 63 - }, - { - "id": 232, - "lighting_type_name": "firestation_sleeping_quarters", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 99 - }, - { - "id": 233, - "lighting_type_name": "post_office_sorting_area", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 121 - }, - { - "id": 234, - "lighting_type_name": "exhibit_convention_center", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 97 - }, - { - "id": 235, - "lighting_type_name": "library_stacks", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 112 - }, - { - "id": 236, - "lighting_type_name": "library_reading", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 111 - }, - { - "id": 237, - "lighting_type_name": "recovery", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 110 - }, - { - "id": 238, - "lighting_type_name": "nurses_station", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 106 - }, - { - "id": 239, - "lighting_type_name": "exam_treatment", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 102 - }, - { - "id": 240, - "lighting_type_name": "pharmacy", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 83 - }, - { - "id": 241, - "lighting_type_name": "patient_room", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 108 - }, - { - "id": 242, - "lighting_type_name": "operating_room", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 107 - }, - { - "id": 243, - "lighting_type_name": "nursery", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 105 - }, - { - "id": 244, - "lighting_type_name": "medical_supply", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 104 - }, - { - "id": 245, - "lighting_type_name": "physical_therapy", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 109 - }, - { - "id": 246, - "lighting_type_name": "imaging", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 103 - }, - { - "id": 247, - "lighting_type_name": "laundry_washing", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 68 - }, - { - "id": 248, - "lighting_type_name": "automotive", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 96 - }, - { - "id": 249, - "lighting_type_name": "manufacturing_low_bay", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 117 - }, - { - "id": 250, - "lighting_type_name": "manufacturing_high_bay", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 116 - }, - { - "id": 251, - "lighting_type_name": "detailed_manufacuring", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 113 - }, - { - "id": 252, - "lighting_type_name": "manufacturing_equipment_room", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 114 - }, - { - "id": 253, - "lighting_type_name": "manufacturing_extra_high_bay", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 115 - }, - { - "id": 254, - "lighting_type_name": "guest_room", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 65 - }, - { - "id": 255, - "lighting_type_name": "dormitory_living_quarters", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 98 - }, - { - "id": 256, - "lighting_type_name": "museum_exhibit_area", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 118 - }, - { - "id": 257, - "lighting_type_name": "museum_restoration", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 119 - }, - { - "id": 258, - "lighting_type_name": "banking_activity", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 44 - }, - { - "id": 259, - "lighting_type_name": "worship_pulpit_choir_area", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 123 - }, - { - "id": 260, - "lighting_type_name": "fellowship_hall_religious_facility", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 122 - }, - { - "id": 261, - "lighting_type_name": "sales", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 86 - }, - { - "id": 262, - "lighting_type_name": "retail_mall_concourse", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 125 - }, - { - "id": 263, - "lighting_type_name": "retail_dressing_room", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 124 - }, - { - "id": 264, - "lighting_type_name": "sports_arena_playing_area_class_I", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 126 - }, - { - "id": 265, - "lighting_type_name": "sports_arena_playing_area_class_II", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 127 - }, - { - "id": 266, - "lighting_type_name": "sports_arena_playing_area_class_III", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 128 - }, - { - "id": 267, - "lighting_type_name": "sports_arena_playing_area_class_IV", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 129 - }, - { - "id": 268, - "lighting_type_name": "warehouse_fine_storage", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 134 - }, - { - "id": 269, - "lighting_type_name": "warehouse_bulk_storage", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 133 - }, - { - "id": 270, - "lighting_type_name": "parking_area_interior", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 82 - }, - { - "id": 271, - "lighting_type_name": "airport_concourse", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 131 - }, - { - "id": 272, - "lighting_type_name": "baggage_carousel", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 130 - }, - { - "id": 273, - "lighting_type_name": "transportation_ticket_counter", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 132 - }, - { - "id": 274, - "lighting_type_name": "sales_display_type_1", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 135 - }, - { - "id": 275, - "lighting_type_name": "sales_display_type_2", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 136 - }, - { - "id": 276, - "lighting_type_name": "sales_display_type_3", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 137 - }, - { - "id": 277, - "lighting_type_name": "sales_display_type_4", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 138 - }, - { - "id": 278, - "lighting_type_name": "breakroom", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 45 - }, - { - "id": 279, - "lighting_type_name": "copy_print", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 50 - }, - { - "id": 280, - "lighting_type_name": "computer_room", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 55 - }, - { - "id": 281, - "lighting_type_name": "loading_dock", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 69 - }, - { - "id": 282, - "lighting_type_name": "locker_room", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 76 - }, - { - "id": 283, - "lighting_type_name": "seating_area_general", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 87 - }, - { - "id": 284, - "lighting_type_name": "vehicular_maintenance", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 92 - }, - { - "id": 285, - "lighting_type_name": "chapel_visually_impaired", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 94 - }, - { - "id": 286, - "lighting_type_name": "recreation_common_living_visually_impaired", - "lighting_table": "light_def_90_1_2019", - "lpd_901_id": 95 - } -] \ No newline at end of file diff --git a/data/openstudio_standards_data/initial_data/lighting_space_tag.json b/data/openstudio_standards_data/initial_data/lighting_space_tag.json deleted file mode 100644 index 44a2358648..0000000000 --- a/data/openstudio_standards_data/initial_data/lighting_space_tag.json +++ /dev/null @@ -1,476 +0,0 @@ -[ - { - "lighting_space_tag": "bam_automotive_facility" - }, - { - "lighting_space_tag": "bam_convention_center" - }, - { - "lighting_space_tag": "bam_courthouse" - }, - { - "lighting_space_tag": "bam_dinin_bar_lounge_leisure" - }, - { - "lighting_space_tag": "bam_dining_cafeteria_fast_food" - }, - { - "lighting_space_tag": "bam_dining_family" - }, - { - "lighting_space_tag": "bam_dormitory" - }, - { - "lighting_space_tag": "bam_exercise_center" - }, - { - "lighting_space_tag": "bam_fire_station" - }, - { - "lighting_space_tag": "bam_gymnasium" - }, - { - "lighting_space_tag": "bam_healthcare_clinic" - }, - { - "lighting_space_tag": "bam_hospital" - }, - { - "lighting_space_tag": "bam_hotel" - }, - { - "lighting_space_tag": "bam_library" - }, - { - "lighting_space_tag": "bam_manufacturing_facility" - }, - { - "lighting_space_tag": "bam_motel" - }, - { - "lighting_space_tag": "bam_motion_picture_theater" - }, - { - "lighting_space_tag": "bam_multifamily" - }, - { - "lighting_space_tag": "bam_museum" - }, - { - "lighting_space_tag": "bam_office" - }, - { - "lighting_space_tag": "bam_parking_garage" - }, - { - "lighting_space_tag": "bam_penitentiary" - }, - { - "lighting_space_tag": "bam_performing_arts_theater" - }, - { - "lighting_space_tag": "bam_police_station" - }, - { - "lighting_space_tag": "bam_post_office" - }, - { - "lighting_space_tag": "bam_religious_facility" - }, - { - "lighting_space_tag": "bam_retail" - }, - { - "lighting_space_tag": "bam_school_university" - }, - { - "lighting_space_tag": "bam_sports_arena" - }, - { - "lighting_space_tag": "bam_town_hall" - }, - { - "lighting_space_tag": "bam_transportation" - }, - { - "lighting_space_tag": "bam_warehouse" - }, - { - "lighting_space_tag": "bam_workshop" - }, - { - "lighting_space_tag": "office_enclosed_small" - }, - { - "lighting_space_tag": "office_enclosed_large" - }, - { - "lighting_space_tag": "office_open" - }, - { - "lighting_space_tag": "conference_meeting_multipurpose" - }, - { - "lighting_space_tag": "classroom_lecture_training_general" - }, - { - "lighting_space_tag": "classroom_lecture_training_penitentiary" - }, - { - "lighting_space_tag": "lobby_general" - }, - { - "lighting_space_tag": "lobby_hotel" - }, - { - "lighting_space_tag": "lobby_performing_arts_theater" - }, - { - "lighting_space_tag": "lobby_motion_picture_theater" - }, - { - "lighting_space_tag": "lobby_visually_impaired" - }, - { - "lighting_space_tag": "lobby_elevator" - }, - { - "lighting_space_tag": "audience_seating_general" - }, - { - "lighting_space_tag": "audience_seating_gymnasium" - }, - { - "lighting_space_tag": "audience_seating_exercise_center" - }, - { - "lighting_space_tag": "audience_seating_convention_center" - }, - { - "lighting_space_tag": "audience_seating_penitentiary" - }, - { - "lighting_space_tag": "audience_seating_religious_facility" - }, - { - "lighting_space_tag": "audience_seating_sports_arena" - }, - { - "lighting_space_tag": "audience_seating_performing_arts_theater" - }, - { - "lighting_space_tag": "audience_seating_motion_picture_theater" - }, - { - "lighting_space_tag": "audience_seating_transportation" - }, - { - "lighting_space_tag": "audience_seating_auditorium" - }, - { - "lighting_space_tag": "atrium_first_three_floor" - }, - { - "lighting_space_tag": "atrium_each_additional_floor" - }, - { - "lighting_space_tag": "atrium_low" - }, - { - "lighting_space_tag": "atrium_medium" - }, - { - "lighting_space_tag": "atrium_high" - }, - { - "lighting_space_tag": "lounge_breakroom_general" - }, - { - "lighting_space_tag": "lounge_breakroom_healthcare_facility" - }, - { - "lighting_space_tag": "dining_general" - }, - { - "lighting_space_tag": "dining_penitentiary" - }, - { - "lighting_space_tag": "dining_hotel" - }, - { - "lighting_space_tag": "dining_motel" - }, - { - "lighting_space_tag": "dining_bar_lounge_leisure" - }, - { - "lighting_space_tag": "dining_family" - }, - { - "lighting_space_tag": "dining_cafeteria_fast_food" - }, - { - "lighting_space_tag": "dining_visually_impaired" - }, - { - "lighting_space_tag": "kitchen" - }, - { - "lighting_space_tag": "laboratory_classroom" - }, - { - "lighting_space_tag": "laboratory_all_other" - }, - { - "lighting_space_tag": "restroom_visually_impaired" - }, - { - "lighting_space_tag": "restroom_all_other" - }, - { - "lighting_space_tag": "performing_arts_dressing_room" - }, - { - "lighting_space_tag": "corridor_general" - }, - { - "lighting_space_tag": "corridor_hospital" - }, - { - "lighting_space_tag": "corridor_manufacturing_facility" - }, - { - "lighting_space_tag": "corridor_visually_impaired" - }, - { - "lighting_space_tag": "stairway" - }, - { - "lighting_space_tag": "stairwell" - }, - { - "lighting_space_tag": "storage_ all_other_small" - }, - { - "lighting_space_tag": "storage_ all_other_large" - }, - { - "lighting_space_tag": "storage_hospital_small" - }, - { - "lighting_space_tag": "storage_hospital_large" - }, - { - "lighting_space_tag": "storage_inactive" - }, - { - "lighting_space_tag": "storage_inactive_museum" - }, - { - "lighting_space_tag": "electrical_mechanical" - }, - { - "lighting_space_tag": "workshop" - }, - { - "lighting_space_tag": "gymnasium_playing_area" - }, - { - "lighting_space_tag": "gymnasium_exercise_area" - }, - { - "lighting_space_tag": "courtroom" - }, - { - "lighting_space_tag": "confinement_cells" - }, - { - "lighting_space_tag": "judges_chambers" - }, - { - "lighting_space_tag": "emergency_vehicle_garage" - }, - { - "lighting_space_tag": "firestation_sleeping_quarters" - }, - { - "lighting_space_tag": "post_office_sorting_area" - }, - { - "lighting_space_tag": "exhibit_convention_center" - }, - { - "lighting_space_tag": "library_cataloging" - }, - { - "lighting_space_tag": "library_stacks" - }, - { - "lighting_space_tag": "library_reading" - }, - { - "lighting_space_tag": "emergency_room" - }, - { - "lighting_space_tag": "recovery" - }, - { - "lighting_space_tag": "nurses_station" - }, - { - "lighting_space_tag": "exam_treatment" - }, - { - "lighting_space_tag": "pharmacy" - }, - { - "lighting_space_tag": "patient_room" - }, - { - "lighting_space_tag": "operating_room" - }, - { - "lighting_space_tag": "nursery" - }, - { - "lighting_space_tag": "medical_supply" - }, - { - "lighting_space_tag": "physical_therapy" - }, - { - "lighting_space_tag": "imaging" - }, - { - "lighting_space_tag": "laundry_washing" - }, - { - "lighting_space_tag": "automotive" - }, - { - "lighting_space_tag": "manufacturing_low_bay" - }, - { - "lighting_space_tag": "manufacturing_high_bay" - }, - { - "lighting_space_tag": "detailed_manufacuring" - }, - { - "lighting_space_tag": "manufacturing_equipment_room" - }, - { - "lighting_space_tag": "manufacturing_control" - }, - { - "lighting_space_tag": "manufacturing_extra_high_bay" - }, - { - "lighting_space_tag": "guest_room" - }, - { - "lighting_space_tag": "dormitory_living_quarters" - }, - { - "lighting_space_tag": "museum_exhibit_area" - }, - { - "lighting_space_tag": "museum_restoration" - }, - { - "lighting_space_tag": "banking_activity" - }, - { - "lighting_space_tag": "worship_pulpit_choir_area" - }, - { - "lighting_space_tag": "fellowship_hall_religious_facility" - }, - { - "lighting_space_tag": "sales" - }, - { - "lighting_space_tag": "retail_mall_concourse" - }, - { - "lighting_space_tag": "retail_dressing_room" - }, - { - "lighting_space_tag": "sports_arena_ring_sports_area" - }, - { - "lighting_space_tag": "sports_arena_court_sports_area" - }, - { - "lighting_space_tag": "sports_arena_indoor_playing_field" - }, - { - "lighting_space_tag": "sports_arena_playing_area_class_I" - }, - { - "lighting_space_tag": "sports_arena_playing_area_class_II" - }, - { - "lighting_space_tag": "sports_arena_playing_area_class_III" - }, - { - "lighting_space_tag": "sports_arena_playing_area_class_IV" - }, - { - "lighting_space_tag": "warehouse_fine_storage" - }, - { - "lighting_space_tag": "warehouse_bulk_storage" - }, - { - "lighting_space_tag": "parking_area_interior" - }, - { - "lighting_space_tag": "airport_concourse" - }, - { - "lighting_space_tag": "baggage_carousel" - }, - { - "lighting_space_tag": "transportation_ticket_counter" - }, - { - "lighting_space_tag": "sales_display_type_1" - }, - { - "lighting_space_tag": "sales_display_type_2" - }, - { - "lighting_space_tag": "sales_display_type_3" - }, - { - "lighting_space_tag": "sales_display_type_4" - }, - { - "lighting_space_tag": "breakroom" - }, - { - "lighting_space_tag": "copy_print" - }, - { - "lighting_space_tag": "computer_room" - }, - { - "lighting_space_tag": "loading_dock" - }, - { - "lighting_space_tag": "locker_room" - }, - { - "lighting_space_tag": "seating_area_general" - }, - { - "lighting_space_tag": "vehicular_maintenance" - }, - { - "lighting_space_tag": "chapel_visually_impaired" - }, - { - "lighting_space_tag": "recreation_common_living_visually_impaired" - } -] \ No newline at end of file diff --git a/data/openstudio_standards_data/initial_data/plug_load_space_tag.json b/data/openstudio_standards_data/initial_data/plug_load_space_tag.json deleted file mode 100644 index e67cf6acce..0000000000 --- a/data/openstudio_standards_data/initial_data/plug_load_space_tag.json +++ /dev/null @@ -1,464 +0,0 @@ -[ - { - "plug_load_space_tag": "corridor - all other" - }, - { - "plug_load_space_tag": "dining - all other" - }, - { - "plug_load_space_tag": "electrical/mechanical" - }, - { - "plug_load_space_tag": "kitchen" - }, - { - "plug_load_space_tag": "laboratory" - }, - { - "plug_load_space_tag": "lobby - all other" - }, - { - "plug_load_space_tag": "locker room" - }, - { - "plug_load_space_tag": "lounge/breakroom - all other" - }, - { - "plug_load_space_tag": "office - enclosed <= 250 sf" - }, - { - "plug_load_space_tag": "office - enclosed > 250 sf" - }, - { - "plug_load_space_tag": "office - open" - }, - { - "plug_load_space_tag": "restroom - all other" - }, - { - "plug_load_space_tag": "stairwell" - }, - { - "plug_load_space_tag": "storage < 50 sf - all other" - }, - { - "plug_load_space_tag": "storage 50 to 1000 sf - all other" - }, - { - "plug_load_space_tag": "vehicular maintenance" - }, - { - "plug_load_space_tag": "atrium - first three floors" - }, - { - "plug_load_space_tag": "audience seating - convention center" - }, - { - "plug_load_space_tag": "classroom/lecture/training - all other" - }, - { - "plug_load_space_tag": "conference/meeting/multipurpose" - }, - { - "plug_load_space_tag": "exhibit - convention center" - }, - { - "plug_load_space_tag": "gymnasium exercise area" - }, - { - "plug_load_space_tag": "gymnasium playing area" - }, - { - "plug_load_space_tag": "laundry/washing" - }, - { - "plug_load_space_tag": "lobby - elevator" - }, - { - "plug_load_space_tag": "nurses station" - }, - { - "plug_load_space_tag": "post office - sorting area" - }, - { - "plug_load_space_tag": "sports arena playing area, class IV" - }, - { - "plug_load_space_tag": "audience seating - all other" - }, - { - "plug_load_space_tag": "confinement cells" - }, - { - "plug_load_space_tag": "judges chambers" - }, - { - "plug_load_space_tag": "library - stacks" - }, - { - "plug_load_space_tag": "storage - inactive" - }, - { - "plug_load_space_tag": "dining - bar/lounge/leisure" - }, - { - "plug_load_space_tag": "dining - cafeteria/fast food" - }, - { - "plug_load_space_tag": "dining - family" - }, - { - "plug_load_space_tag": "computer room" - }, - { - "plug_load_space_tag": "dormitory - living quarters" - }, - { - "plug_load_space_tag": "audience seating - exercise center" - }, - { - "plug_load_space_tag": "exam/treatment" - }, - { - "plug_load_space_tag": "library - reading" - }, - { - "plug_load_space_tag": "emergency vehicle garage" - }, - { - "plug_load_space_tag": "firestation - sleeping quarters" - }, - { - "plug_load_space_tag": "parking area, interior" - }, - { - "plug_load_space_tag": "audience seating - gymnasium" - }, - { - "plug_load_space_tag": "emergency room" - }, - { - "plug_load_space_tag": "patient room" - }, - { - "plug_load_space_tag": "corridor - hospital" - }, - { - "plug_load_space_tag": "fellowship hall - religious facility" - }, - { - "plug_load_space_tag": "lounge/breakroom - healthcare facility" - }, - { - "plug_load_space_tag": "operating room" - }, - { - "plug_load_space_tag": "physical therapy" - }, - { - "plug_load_space_tag": "storage < 50 sf - hospital" - }, - { - "plug_load_space_tag": "storage 50 to 1000 sf - hospital" - }, - { - "plug_load_space_tag": "guest room" - }, - { - "plug_load_space_tag": "lobby - hotel" - }, - { - "plug_load_space_tag": "library - cataloging" - }, - { - "plug_load_space_tag": "museum exhibit area" - }, - { - "plug_load_space_tag": "corridor - manufacturing facility" - }, - { - "plug_load_space_tag": "manufacturing equipment room" - }, - { - "plug_load_space_tag": "manufacturing low bay" - }, - { - "plug_load_space_tag": "performing arts dressing room" - }, - { - "plug_load_space_tag": "audience seating - auditorium" - }, - { - "plug_load_space_tag": "audience seating - motion picture theater" - }, - { - "plug_load_space_tag": "lobby - motion picture theater" - }, - { - "plug_load_space_tag": "Dwelling Unit" - }, - { - "plug_load_space_tag": "museum restoration" - }, - { - "plug_load_space_tag": "banking activity" - }, - { - "plug_load_space_tag": "warehouse - fine storage" - }, - { - "plug_load_space_tag": "classroom/lecture/training - penitentiary" - }, - { - "plug_load_space_tag": "dining - penitentiary" - }, - { - "plug_load_space_tag": "audience seating - performing arts theater" - }, - { - "plug_load_space_tag": "lobby - performing arts theater" - }, - { - "plug_load_space_tag": "audience seating - religious facility" - }, - { - "plug_load_space_tag": "worship/pulpit/choir area" - }, - { - "plug_load_space_tag": "classroom/lecture/training - preschool to 12th" - }, - { - "plug_load_space_tag": "sports arena playing area, class II" - }, - { - "plug_load_space_tag": "audience seating - sports arena" - }, - { - "plug_load_space_tag": "airport concourse" - }, - { - "plug_load_space_tag": "atrium < 20 ft height" - }, - { - "plug_load_space_tag": "atrium > 40 ft height" - }, - { - "plug_load_space_tag": "atrium >= 20 ft and <= 40 ft in height" - }, - { - "plug_load_space_tag": "baggage/carousel" - }, - { - "plug_load_space_tag": "seating area, general" - }, - { - "plug_load_space_tag": "transportation ticket counter" - }, - { - "plug_load_space_tag": "warehouse - bulk storage" - }, - { - "plug_load_space_tag": "workshop" - }, - { - "plug_load_space_tag": "gymnasium_playing_area" - }, - { - "plug_load_space_tag": "gymnasium_exercise_area" - }, - { - "plug_load_space_tag": "courtroom" - }, - { - "plug_load_space_tag": "confinement_cells" - }, - { - "plug_load_space_tag": "judges_chambers" - }, - { - "plug_load_space_tag": "emergency_vehicle_garage" - }, - { - "plug_load_space_tag": "firestation_sleeping_quarters" - }, - { - "plug_load_space_tag": "post_office_sorting_area" - }, - { - "plug_load_space_tag": "exhibit_convention_center" - }, - { - "plug_load_space_tag": "library_cataloging" - }, - { - "plug_load_space_tag": "library_stacks" - }, - { - "plug_load_space_tag": "library_reading" - }, - { - "plug_load_space_tag": "emergency_room" - }, - { - "plug_load_space_tag": "recovery" - }, - { - "plug_load_space_tag": "nurses_station" - }, - { - "plug_load_space_tag": "exam_treatment" - }, - { - "plug_load_space_tag": "pharmacy" - }, - { - "plug_load_space_tag": "patient_room" - }, - { - "plug_load_space_tag": "operating_room" - }, - { - "plug_load_space_tag": "nursery" - }, - { - "plug_load_space_tag": "medical_supply" - }, - { - "plug_load_space_tag": "physical_therapy" - }, - { - "plug_load_space_tag": "imaging" - }, - { - "plug_load_space_tag": "laundry_washing" - }, - { - "plug_load_space_tag": "automotive" - }, - { - "plug_load_space_tag": "manufacturing_low_bay" - }, - { - "plug_load_space_tag": "manufacturing_high_bay" - }, - { - "plug_load_space_tag": "detailed_manufacuring" - }, - { - "plug_load_space_tag": "manufacturing_equipment_room" - }, - { - "plug_load_space_tag": "manufacturing_control" - }, - { - "plug_load_space_tag": "manufacturing_extra_high_bay" - }, - { - "plug_load_space_tag": "guest_room" - }, - { - "plug_load_space_tag": "dormitory_living_quarters" - }, - { - "plug_load_space_tag": "museum_exhibit_area" - }, - { - "plug_load_space_tag": "museum_restoration" - }, - { - "plug_load_space_tag": "banking_activity" - }, - { - "plug_load_space_tag": "worship_pulpit_choir_area" - }, - { - "plug_load_space_tag": "fellowship_hall_religious_facility" - }, - { - "plug_load_space_tag": "sales" - }, - { - "plug_load_space_tag": "retail_mall_concourse" - }, - { - "plug_load_space_tag": "retail_dressing_room" - }, - { - "plug_load_space_tag": "sports_arena_ring_sports_area" - }, - { - "plug_load_space_tag": "sports_arena_court_sports_area" - }, - { - "plug_load_space_tag": "sports_arena_indoor_playing_field" - }, - { - "plug_load_space_tag": "sports_arena_playing_area_class_I" - }, - { - "plug_load_space_tag": "sports_arena_playing_area_class_II" - }, - { - "plug_load_space_tag": "sports_arena_playing_area_class_III" - }, - { - "plug_load_space_tag": "sports_arena_playing_area_class_IV" - }, - { - "plug_load_space_tag": "warehouse_fine_storage" - }, - { - "plug_load_space_tag": "warehouse_bulk_storage" - }, - { - "plug_load_space_tag": "parking_area_interior" - }, - { - "plug_load_space_tag": "airport_concourse" - }, - { - "plug_load_space_tag": "baggage_carousel" - }, - { - "plug_load_space_tag": "transportation_ticket_counter" - }, - { - "plug_load_space_tag": "sales_display_type_1" - }, - { - "plug_load_space_tag": "sales_display_type_2" - }, - { - "plug_load_space_tag": "sales_display_type_3" - }, - { - "plug_load_space_tag": "sales_display_type_4" - }, - { - "plug_load_space_tag": "breakroom" - }, - { - "plug_load_space_tag": "copy_print" - }, - { - "plug_load_space_tag": "computer_room" - }, - { - "plug_load_space_tag": "loading_dock" - }, - { - "plug_load_space_tag": "locker_room" - }, - { - "plug_load_space_tag": "seating_area_general" - }, - { - "plug_load_space_tag": "vehicular_maintenance" - }, - { - "plug_load_space_tag": "chapel_visually_impaired" - }, - { - "plug_load_space_tag": "recreation_common_living_visually_impaired" - } -] \ No newline at end of file diff --git a/data/openstudio_standards_data/initial_data/standard_template.json b/data/openstudio_standards_data/initial_data/standard_template.json deleted file mode 100644 index 18e6f9b0fc..0000000000 --- a/data/openstudio_standards_data/initial_data/standard_template.json +++ /dev/null @@ -1,18 +0,0 @@ -[ - { - "id": 1, - "template": "2019", - "lighting_standard": "ASHRAE 90.1-2019", - "lighting_standard_table": "light_def_90_1_2019", - "ventilation_standard": "ASHRAE 62.1-2019", - "ventilation_standard_table": "vent_def_62_1_2019" - }, - { - "id": 2, - "template": "2004", - "lighting_standard": "ASHRAE 90.1-2004", - "lighting_standard_table": "light_def_90_1_2004", - "ventilation_standard": "ASHRAE 62.1-2004", - "ventilation_standard_table": "vent_def_62_1_2004" - } -] \ No newline at end of file diff --git a/data/openstudio_standards_data/initial_data/support_constructions.csv b/data/openstudio_standards_data/initial_data/support_constructions.csv deleted file mode 100644 index be2b48475b..0000000000 --- a/data/openstudio_standards_data/initial_data/support_constructions.csv +++ /dev/null @@ -1,492 +0,0 @@ -name,intended_surface_type,standard_construction_type,insulation_layer,skylight_framing,material_1,material_2,material_3,material_4,material_5,material_6 -Typical Attic Floor,AtticFloor,WoodFramed,Typical Insulation,,1/2IN Gypsum,Typical Insulation,1/2IN Gypsum,,, -Typical Wood Joist Attic Floor,AtticFloor,WoodFramed,Typical Insulation,,5/8 in. Gypsum Board,Typical Insulation,,,, -Typical Wood Joist Attic Floor Ceiling,AtticFloor,WoodFramed,,,Typical Insulation,5/8 in. Gypsum Board,,,, -Typical Uninsulated Metal Roof Attic Roof,AtticRoof,WoodFramed,,,Roof Membrane,Metal Decking,,,, -Typical Uninsulated Wood Joist Attic Roof,AtticRoof,WoodFramed,,,Asphalt Shingles,5/8 in. Plywood,,,, -Typical Attic Soffit,AtticWall,,,,5/8 in. Plywood,,,,, -Typical Insulated Metal Door,ExteriorDoor,,Typical Insulation,,F08 Metal surface,Typical Insulation,,,, -Typical Overhead Door,ExteriorDoor,RollUp,Typical Insulation,,Typical Insulation,,,,, -Typical Uninsulated Swinging Door,ExteriorDoor,Swinging,Typical Insulation,,Typical Insulation,,,,, -Adiabatic ExteriorFloor,ExteriorFloor,Mass,,,Adiabatic Material,,,,, -Typical Carpeted 4in Slab Floor,ExteriorFloor,,,,MAT-CC05 4 HW CONCRETE,Typical Carpet Pad,,,, -Typical Insulated Carpeted 4in Slab Floor,ExteriorFloor,,Typical Insulation,,Typical Insulation,MAT-CC05 4 HW CONCRETE,Typical Carpet Pad,,, -Typical Insulated Exterior Mass Floor,ExteriorFloor,Mass,Typical Insulation,,Typical Insulation,4 in. Normalweight Concrete Floor,Typical Carpet Pad,,, -Typical Insulated Exterior Mass Floor Ceiling,ExteriorFloor,Mass,Typical Insulation,,Typical Carpet Pad,4 in. Normalweight Concrete Floor,Typical Insulation,,, -Typical Insulated Steel Framed Exterior Floor,ExteriorFloor,SteelFramed,Typical Insulation,,25mm Stucco,5/8 in. Gypsum Board,Typical Insulation,5/8 in. Gypsum Board,Typical Carpet Pad, -Typical Insulated Wood Framed Exterior Floor,ExteriorFloor,WoodFramed,Typical Insulation,,25mm Stucco,5/8 in. Gypsum Board,Typical Insulation,5/8 in. Gypsum Board,Typical Carpet Pad, -Typical Uncarpeted 4in Slab Floor,ExteriorFloor,,,,MAT-CC05 4 HW CONCRETE,,,,, -Adiabatic Roof,ExteriorRoof,Attic and Other,,,Adiabatic Material,,,,, -Metal roofR_R30,ExteriorRoof,,Typical Insulation,,Metal Standing Seam - 1/16 in. CBES,R_R30,,,, -Metal roofR_R38,ExteriorRoof,,Typical Insulation,,Metal Standing Seam - 1/16 in. CBES,R_R38,,,, -Metal roofR_T24_2013_24.86,ExteriorRoof,,Typical Insulation,,Metal Standing Seam - 1/16 in. CBES,R_T24_2013_24.86,,,, -Metal roofR1_R14.20,ExteriorRoof,,Typical Insulation,,Metal Standing Seam - 1/16 in. CBES,R1_R14.20,,,, -Metal roofR2_R12.90,ExteriorRoof,,Typical Insulation,,Metal Standing Seam - 1/16 in. CBES,R2_R12.90,,,, -Metal roofR3_R17.74,ExteriorRoof,,Typical Insulation,,Metal Standing Seam - 1/16 in. CBES,R3_R17.74,,,, -Metal roofR4_R20.28,ExteriorRoof,,Typical Insulation,,Metal Standing Seam - 1/16 in. CBES,R4_R20.28,,,, -Typical Built Up Roof,ExteriorRoof,IEAD,Typical Insulation,,Built-up Roofing,Typical Insulation,Metal Surface,,, -Typical Built Up Roof - Highly Reflective,ExteriorRoof,IEAD,Typical Insulation,,Built-up Roofing - Highly Reflective,Typical Insulation,Metal Surface,,, -Typical IEAD Roof,ExteriorRoof,IEAD,Typical Insulation,,Roof Membrane,Typical Insulation,Metal Roof Surface,,, -Typical IEAD Roof - Highly Reflective,ExteriorRoof,IEAD,Typical Insulation,,Roof Membrane - Highly Reflective,Typical Insulation,Metal Roof Surface,,, -Typical Insulated Metal Building Roof,ExteriorRoof,Metal Building,Typical Insulation,,Metal Roof Surface,Typical Insulation,,,, -Typical Insulated Metal Building Roof - Highly Reflective,ExteriorRoof,Metal Building,Typical Insulation,,Metal Roof Surface - Highly Reflective,Typical Insulation,,,, -Typical Uninsulated Metal Building Roof,ExteriorRoof,Metal Building,,,Metal Roofing,,,,, -Typical Uninsulated Metal Building Roof - Highly Reflective,ExteriorRoof,Metal Building,,,Metal Roofing - Highly Reflective,,,,, -Adiabatic Wall,ExteriorWall,Mass,,,Adiabatic Material,,,,, -Metal framed wallsW_m1_R15,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W_m1_R15,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, -Metal framed wallsW_m2_R19,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W_m2_R19,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, -Metal framed wallsW_m3_R21,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W_m3_R21,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, -Metal framed wallsW_T24_2013_R13.99,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W_T24_2013_R13.99,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, -Metal framed wallsW1_R8.60,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W1_R8.60,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, -Metal framed wallsW2_R11.13,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W2_R11.13,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, -Metal framed wallsW3_R11.36,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W3_R11.36,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, -Metal framed wallsW4_R12.62,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W4_R12.62,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, -Typical Insulated Exterior Mass Wall,ExteriorWall,Mass,Typical Insulation,,1IN Stucco,8IN CONCRETE HW RefBldg,Typical Insulation,1/2IN Gypsum,, -Typical Insulated Metal Building Wall,ExteriorWall,Metal Building,Typical Insulation,,Metal Siding,Typical Insulation,1/2IN Gypsum,,, -Typical Insulated Steel Framed Exterior Wall,ExteriorWall,SteelFramed,Typical Insulation,,25mm Stucco,5/8 in. Gypsum Board,Typical Insulation,5/8 in. Gypsum Board,, -Typical Insulated Wood Framed Exterior Wall,ExteriorWall,WoodFramed,Typical Insulation,,25mm Stucco,5/8 in. Gypsum Board,Typical Insulation,5/8 in. Gypsum Board,, -Typical Uninsulated Exterior Mass Wall,ExteriorWall,Mass,,,1IN Stucco,8IN CONCRETE HW RefBldg,1/2IN Gypsum,,, -Typical Uninsulated Metal Building Wall,ExteriorWall,Metal Building,,,Metal Siding,1/2IN Gypsum,,,, -Typical Uninsulated Steel Framed Exterior Wall,ExteriorWall,SteelFramed,,,Wood Siding,1/2IN Gypsum,,,, -WoodWallU110,ExteriorWall,,,,Plywood - 5/8 in.,Compliance Insulation R6.46,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 3/8 in.,, -ASHRAE 189.1-2009 ExtWindow ClimateZone 1,ExteriorWindow,,,,Theoretical Glass [167],,,,, -ASHRAE 189.1-2009 ExtWindow ClimateZone 2,ExteriorWindow,,,,Theoretical Glass [197],,,,, -ASHRAE 189.1-2009 ExtWindow ClimateZone 3,ExteriorWindow,,,,Theoretical Glass [202],,,,, -ASHRAE 189.1-2009 ExtWindow ClimateZone 4-5,ExteriorWindow,,,,Theoretical Glass [207],,,,, -ASHRAE 189.1-2009 ExtWindow ClimateZone 6,ExteriorWindow,,,,Theoretical Glass [216],,,,, -ASHRAE 189.1-2009 ExtWindow ClimateZone 7-8,ExteriorWindow,,,,Theoretical Glass [221],,,,, -ASHRAE 189.1-2009 ExtWindow ClimateZone alt-res 4-5,ExteriorWindow,,,,Theoretical Glass [216],,,,, -U 0.11 SHGC 0.34 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.11 SHGC 0.34 Simple Glazing,,,,, -U 0.11 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.11 SHGC 0.38 Simple Glazing,,,,, -U 0.12 SHGC 0.34 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.12 SHGC 0.34 Simple Glazing,,,,, -U 0.12 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.12 SHGC 0.38 Simple Glazing,,,,, -U 0.13 SHGC 0.32 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.13 SHGC 0.32 Simple Glazing,,,,, -U 0.13 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.13 SHGC 0.38 Simple Glazing,,,,, -U 0.14 SHGC 0.31 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.14 SHGC 0.31 Simple Glazing,,,,, -U 0.14 SHGC 0.34 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.14 SHGC 0.34 Simple Glazing,,,,, -U 0.14 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.14 SHGC 0.36 Simple Glazing,,,,, -U 0.14 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.14 SHGC 0.38 Simple Glazing,,,,, -U 0.15 SHGC 0.31 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.15 SHGC 0.31 Simple Glazing,,,,, -U 0.15 SHGC 0.34 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.15 SHGC 0.34 Simple Glazing,,,,, -U 0.17 SHGC 0.31 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.17 SHGC 0.31 Simple Glazing,,,,, -U 0.17 SHGC 0.32 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.17 SHGC 0.32 Simple Glazing,,,,, -U 0.17 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.17 SHGC 0.36 Simple Glazing,,,,, -U 0.18 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.18 SHGC 0.22 Simple Glazing,,,,, -U 0.18 SHGC 0.24 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.18 SHGC 0.24 Simple Glazing,,,,, -U 0.19 SHGC 0.20 Trp LoE Film (55) Bronze 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,BRONZE 6MM,AIR 13MM,COATED POLY-55,AIR 13MM,CLEAR 3MM, -U 0.20 SHGC 0.19 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.20 SHGC 0.19 Simple Glazing,,,,, -U 0.20 SHGC 0.20 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.20 SHGC 0.20 Simple Glazing,,,,, -U 0.20 SHGC 0.21 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.20 SHGC 0.21 Simple Glazing,,,,, -U 0.20 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.20 SHGC 0.22 Simple Glazing,,,,, -U 0.23 SHGC 0.31 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.23 SHGC 0.31 Simple Glazing,,,,, -U 0.23 SHGC 0.34 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.23 SHGC 0.34 Simple Glazing,,,,, -U 0.24 SHGC 0.11 Dbl LoE Elec Abs Colored 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,ECABS-2 COLORED 6MM,ARGON 13MM,LoE SPEC SEL CLEAR 6MM Rev,,, -U 0.24 SHGC 0.16 Dbl Elec Abs Colored 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,ECABS-2 COLORED 6MM,ARGON 13MM,CLEAR 6MM,,, -U 0.24 SHGC 0.23 Dbl LoE Spec Sel Tint 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,LoE SPEC SEL TINT 6MM,ARGON 13MM,CLEAR 6MM,,, -U 0.25 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.25 SHGC 0.22 Simple Glazing,,,,, -U 0.25 SHGC 0.24 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.25 SHGC 0.24 Simple Glazing,,,,, -U 0.25 SHGC 0.40 Dbl LoE (e2-.1) Tint 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,LoE TINT 6MM,ARGON 13MM,CLEAR 6MM,,, -U 0.26 SHGC 0.40 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.26 SHGC 0.40 Simple Glazing,,,,, -U 0.29 SHGC 0.11 Dbl LoE Elec Ref Colored 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,ECREF-2 COLORED 6MM,AIR 13MM,LoE SPEC SEL CLEAR 6MM Rev,,, -U 0.29 SHGC 0.17 Dbl Elec Abs Colored 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,ECABS-2 COLORED 6MM,AIR 13MM,CLEAR 6MM,,, -U 0.29 SHGC 0.22 Trp LoE Film (55) Bronze 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,BRONZE 6MM,AIR 6MM,COATED POLY-55,AIR 6MM,CLEAR 3MM, -U 0.29 SHGC 0.40 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.29 SHGC 0.40 Simple Glazing,,,,, -U 0.30 SHGC 0.40 Dbl LoE (e2-.1) Tint 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,LoE TINT 6MM,AIR 13MM,CLEAR 6MM,,, -U 0.32 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.32 SHGC 0.36 Simple Glazing,,,,, -U 0.33 SHGC 0.11 Dbl LoE Elec Ref Colored 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,ECREF-2 COLORED 6MM,AIR 13MM,LoE SPEC SEL CLEAR 6MM Rev,,, -U 0.33 SHGC 0.40 Dbl LoE (e2-.1) Tint 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,LoE TINT 6MM,AIR 13MM,CLEAR 6MM,,, -U 0.33 SHGC 0.45 Trp LoE Film (77) Clr 3mm/6mm Air,ExteriorWindow,Metal framing (all other),,,CLEAR 3MM,AIR 6MM,COATED POLY-77,AIR 6MM,CLEAR 3MM, -U 0.34 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.34 SHGC 0.38 Simple Glazing,,,,, -U 0.34 SHGC 0.40 Dbl LoE (e2-.1) Tint 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,LoE TINT 6MM,AIR 13MM,CLEAR 6MM,,, -U 0.34 SHGC 0.45 Dbl LoE (e2-.2) Clr 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,PYR B CLEAR 6MM,AIR 13MM,CLEAR 6MM,,, -U 0.35 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.35 SHGC 0.22 Simple Glazing,,,,, -U 0.35 SHGC 0.24 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.35 SHGC 0.24 Simple Glazing,,,,, -U 0.35 SHGC 0.26 Dbl Ref-C-M Clr 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,REF C CLEAR MID 6MM,ARGON 13MM,CLEAR 6MM,,, -U 0.35 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,LoE TINT 6MM,AIR 13MM,CLEAR 6MM,,, -U 0.36 SHGC 0.35 Dbl LoE Spec Sel Tint 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,LoE SPEC SEL TINT 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.36 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.36 SHGC 0.36 Simple Glazing,,,,, -U 0.36 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.36 SHGC 0.38 Simple Glazing,,,,, -U 0.38 SHGC 0.26 Dbl Ref B-H Tint 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,REF B TINT HI 6MM,ARGON 13MM,CLEAR 6MM,,, -U 0.38 SHGC 0.30 Dbl Ref-B-H Clr 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,ARGON 13MM,CLEAR 6MM,,, -U 0.39 SHGC 0.32,ExteriorWindow,Metal framing (all other),,,Theoretical Glass 347,,,,, -U 0.39 SHGC 0.38,ExteriorWindow,Metal framing (all other),,,Theoretical Glass 297,,,,, -U 0.40 SHGC 0.43 Dbl LoE Spec Sel Clr 3mm/6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,LoE SPEC SEL CLEAR 3MM,AIR 6MM,CLEAR 6MM,,, -U 0.40 SHGC 0.45,ExteriorWindow,Metal framing (all other),,,ECABS-2 BLEACHED 6MM,AIR 6MM,LoE SPEC SEL CLEAR 6MM Rev,,, -U 0.42 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.42 SHGC 0.25 Simple Glazing,,,,, -U 0.42 SHGC 0.34 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.42 SHGC 0.34 Simple Glazing,,,,, -U 0.42 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,LoE TINT 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.42 SHGC 0.40 Dbl LoE (e2-.1) Tint 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,LoE TINT 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.42 SHGC 0.45 Dbl Ref-D Clr 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,REF D CLEAR 6MM,ARGON 13MM,CLEAR 6MM,,, -U 0.43 SHGC 0.26 Dbl Ref-B-H Clr 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,AIR 13MM,CLEAR 6MM,,, -U 0.43 SHGC 0.29 Dbl LoE Spec Sel Tint 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,LoE SPEC SEL TINT 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.44 SHGC 0.20 Dbl Ref-B-H Tint 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,REF B TINT HI 6MM,AIR 13MM,CLEAR 6MM,,, -U 0.44 SHGC 0.26 Dbl Ref-B-H Clr 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,AIR 13MM,CLEAR 6MM,,, -U 0.45 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.45 SHGC 0.25 Simple Glazing,,,,, -U 0.45 SHGC 0.31 Dbl Ref-B-H Clr 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,AIR 13MM,CLEAR 6MM,,, -U 0.45 SHGC 0.33 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.45 SHGC 0.33 Simple Glazing,,,,, -U 0.46 SHGC 0.45 Dbl Grey 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,GREY 6MM,AIR 13MM,CLEAR 6MM,,, -U 0.47 SHGC 0.33 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.47 SHGC 0.33 Simple Glazing,,,,, -U 0.48 SHGC 0.19 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.48 SHGC 0.19 Simple Glazing,,,,, -U 0.48 SHGC 0.21 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.48 SHGC 0.21 Simple Glazing,,,,, -U 0.48 SHGC 0.20 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.48 SHGC 0.20 Simple Glazing,,,,, -U 0.48 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.48 SHGC 0.22 Simple Glazing,,,,, -U 0.48 SHGC 0.40 Dbl Ref-D Clr 6mm/13mm,ExteriorWindow,Metal framing (all other),,,REF D CLEAR 6MM,AIR 13MM,CLEAR 6MM,,, -U 0.50 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.50 SHGC 0.22 Simple Glazing,,,,, -U 0.50 SHGC 0.23 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.50 SHGC 0.23 Simple Glazing,,,,, -U 0.52 SHGC 0.22 Dbl Ref-B-L Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF B CLEAR LO 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.52 SHGC 0.39 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.52 SHGC 0.39 Simple Glazing,,,,, -U 0.52 SHGC 0.40 Dbl Ref-D Clr 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,REF D CLEAR 6MM,AIR 13MM,CLEAR 6MM,,, -U 0.52 SHGC 0.49 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.52 SHGC 0.49 Simple Glazing,,,,, -U 0.52 SHGC 0.615 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.52 SHGC 0.615 Simple Glazing,,,,, -U 0.54 SHGC 0.13 Dbl Ref-A-L Clr 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,REF A CLEAR LO 6MM,AIR 13MM,CLEAR 6MM,,, -U 0.54 SHGC 0.18 Dbl Ref-A-M Tint 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF A TINT MID 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.54 SHGC 0.23 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.54 SHGC 0.23 Simple Glazing,,,,, -U 0.54 SHGC 0.27 Dbl Ref-C-H Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF C CLEAR HI 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.55 SHGC 0.25,ExteriorWindow,Metal framing (all other),,,Glass_2175_LayerAvg,Gap_1_W_0_0032,Glass_2022F_LayerAvg,,, -U 0.55 SHGC 0.31 Dbl Ref-D Tint 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF D TINT 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.56 SHGC 0.35 Dbl Ref-D Tint 6mm/6mm,ExteriorWindow,Metal framing (all other),,,REF D TINT 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.56 SHGC 0.76 Dbl Clr 3mm/6mm Air,ExteriorWindow,Metal framing (all other),,,CLEAR 3MM,AIR 6MM,CLEAR 3MM,,, -U 0.57 SHGC 0.25 Dbl Ref-C-H Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF C CLEAR HI 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF D CLEAR 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,BLUE 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.59 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.59 SHGC 0.36 Simple Glazing,,,,, -U 0.59 SHGC 0.39 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.59 SHGC 0.39 Simple Glazing,,,,, -U 0.60 SHGC 0.23 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.60 SHGC 0.23 Simple Glazing,,,,, -U 0.62 SHGC 0.20 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.62 SHGC 0.20 Simple Glazing,,,,, -U 0.62 SHGC 0.21 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.62 SHGC 0.21 Simple Glazing,,,,, -U 0.62 SHGC 0.25 Dbl Ref-C-H Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF C CLEAR HI 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.62 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF D CLEAR 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.62 SHGC 0.41 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.62 SHGC 0.41 Simple Glazing,,,,, -U 0.62 SHGC 0.49 Dbl Blue 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,BLUE 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.65 SHGC 0.25 Dbl Ref-C-H Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF C CLEAR HI 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.67 SHGC 0.77 Sgl LoE (e2-.2) Clr 3mm,ExteriorWindow,Metal framing (all other),,,PYR B CLEAR 3MM,,,,, -U 0.71 SHGC 0.25 Dbl Ref-C-H Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF C CLEAR HI 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.72 SHGC 0.25 Sgl Ref-B-M Tint 6mm,ExteriorWindow,Metal framing (all other),,,REF B TINT MID 6MM,,,,, -U 0.72 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.72 SHGC 0.25 Simple Glazing,,,,, -U 0.72 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.72 SHGC 0.36 Simple Glazing,,,,, -U 0.72 SHGC 0.39 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.72 SHGC 0.39 Simple Glazing,,,,, -U 0.75 SHGC 0.72 Sgl LoE (e2-.2) Clr 6mm,ExteriorWindow,Metal framing (all other),,,PYR B CLEAR 6MM,,,,, -U 0.88 SHGC 0.16 Sgl Ref-A-L Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF A CLEAR LO 6MM,,,,, -U 0.88 SHGC 0.27 Sgl Elec Ref Colored 6mm,ExteriorWindow,Metal framing (all other),,,ECREF-1 COLORED 6MM,,,,, -U 0.98 SHGC 0.45 Sgl Ref-B-H Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,,,,, -U 0.98 SHGC 0.68 Sgl Ref-B-H Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,,,,, -U 1.17 SHGC 0.39 Sgl Ref-B-H Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,,,,, -U 1.17 SHGC 0.49 Sgl Ref-D Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF D CLEAR 6MM,,,,, -U 1.17 SHGC 0.68 Sgl Green 3mm,ExteriorWindow,Metal framing (all other),,,GREEN 3MM,,,,, -U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm,ExteriorWindow,Metal framing (all other),,,ECREF-1 COLORED 6MM,,,,, -U 1.22 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 1.22 SHGC 0.25 Simple Glazing,,,,, -U 1.22 SHGC 0.34 Sgl Ref-C-H Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF C CLEAR HI 6MM,,,,, -U 1.22 SHGC 0.39 Sgl Ref-B-H Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,,,,, -U 1.22 SHGC 0.54 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 1.22 SHGC 0.54 Simple Glazing,,,,, -U 1.22 SHGC 0.61 Sgl Green 6mm,ExteriorWindow,Metal framing (all other),,,GREEN 6MM,,,,, -U 1.98 SHGC 0.36 Sgl Ref-B-H Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,,,,, -U 1.98 SHGC 0.61 Sgl Green 6mm,ExteriorWindow,Metal framing (all other),,,GREEN 6MM,,,,, -U0.47_SHGC_0.49_SimpleGlazing_Window_05,ExteriorWindow,,,,U0.47_SHGC_0.49_SimpleGlazing_Window_05,,,,, -U0.47_SHGC0.46_SimpleGlazing_Window_07,ExteriorWindow,,,,U0.47_SHGC0.46_SimpleGlazing_Window_07,,,,, -U0.47_SHGC0.47_SimpleGlazing_Window_06,ExteriorWindow,,,,U0.47_SHGC0.47_SimpleGlazing_Window_06,,,,, -U0.47_SHGC0.47_SimpleGlazing_Window_11,ExteriorWindow,,,,U0.47_SHGC0.47_SimpleGlazing_Window_11,,,,, -U0.47_SHGC0.5_SimpleGlazing_Window_03,ExteriorWindow,,,,U0.47_SHGC0.5_SimpleGlazing_Window_03,,,,, -U0.77_SHGC_0.77_SimpleGlazing_Window_02,ExteriorWindow,,,,U0.77_SHGC_0.77_SimpleGlazing_Window_02,,,,, -U0.77_SHGC0.5_SimpleGlazing_Window_09,ExteriorWindow,,,,U0.77_SHGC0.5_SimpleGlazing_Window_09,,,,, -U0.77_SHGC0.61_SimpleGlazing_Window_08,ExteriorWindow,,,,U0.77_SHGC0.61_SimpleGlazing_Window_08,,,,, -U0.77_SHGC0.62_SimpleGlazing_Window_04,ExteriorWindow,,,,U0.77_SHGC0.62_SimpleGlazing_Window_04,,,,, -U1.23_SHGC0.5_SimpleGlazing_Window_12,ExteriorWindow,,,,U1.23_SHGC0.5_SimpleGlazing_Window_12,,,,, -U1.23_SHGC0.82_SimpleGlazing_Window_01,ExteriorWindow,,,,U1.23_SHGC0.82_SimpleGlazing_Window_01,,,,, -U1.23_SHGC0.82_SimpleGlazing_Window_10,ExteriorWindow,,,,U1.23_SHGC0.82_SimpleGlazing_Window_10,,,,, -Adiabatic GroundContactFloor,GroundContactFloor,Mass,,,Adiabatic Material,,,,, -ext-slab,GroundContactFloor,Mass,,,6 in. Normalweight Concrete Floor,,,,, -ext-slab-mass,GroundContactFloor,Mass,CP02 CARPET PAD,,HW CONCRETE,CP02 CARPET PAD,,,, -ext-slab-metal-building,GroundContactFloor,Metal Building,,,HW CONCRETE 8 in,,,,, -ext-slab-steel-frame,GroundContactFloor,SteelFramed,CP02 CARPET PAD,,HW CONCRETE 8 in,CP02 CARPET PAD,,,, -Ground FloorGround_Floor_R11_T2013,GroundContactFloor,,,,Ground_Floor_R11_T2013,Plywood - 5/8 in. CBES,Carpet - 3/4 in. CBES,,, -Ground FloorGround_Floor_R17_T2013,GroundContactFloor,,,,Ground_Floor_R17_T2013,Plywood - 5/8 in. CBES,Carpet - 3/4 in. CBES,,, -Ground FloorGround_Floor_R22_T2013,GroundContactFloor,,,,Ground_Floor_R22_T2013,Plywood - 5/8 in. CBES,Carpet - 3/4 in. CBES,,, -Smallhotel 2010 Slab Floor,GroundContactFloor,Mass,Typical Insulation,,8 in. Normalweight Concrete Floor,CP02 CARPET PAD,,,, -Typical Carpeted 6in Slab Floor,GroundContactFloor,Mass,,,6 in. Normalweight Concrete Floor,Typical Carpet Pad,,,, -Typical Carpeted 8in Slab Floor,GroundContactFloor,Mass,,,8 in. Normalweight Concrete Floor,Typical Carpet Pad,,,, -Typical Insulated 6in Slab Floor,GroundContactFloor,Mass,Typical Insulation,,Typical Insulation,6 in. Normalweight Concrete Floor,,,, -Typical Insulated 8in Slab Floor,GroundContactFloor,Mass,Typical Insulation,,Typical Insulation,8 in. Normalweight Concrete Floor,,,, -Typical Insulated Carpeted 6in Slab Floor,GroundContactFloor,Mass,Typical Insulation,,Typical Insulation,6 in. Normalweight Concrete Floor,Typical Carpet Pad,,, -Typical Insulated Carpeted 8in Slab Floor,GroundContactFloor,Mass,Typical Insulation,,Typical Insulation,8 in. Normalweight Concrete Floor,Typical Carpet Pad,,, -Typical Uncarpeted 6in Slab Floor,GroundContactFloor,Mass,,,6 in. Normalweight Concrete Floor,,,,, -Typical Uninsulated 6in Slab Floor,GroundContactFloor,Mass,,,6 in. Normalweight Concrete Floor,,,,, -Typical Uninsulated 8in Slab Floor,GroundContactFloor,Mass,,,8 in. Normalweight Concrete Floor,,,,, -Typical Uninsulated Carpeted 8in Slab Floor,GroundContactFloor,Mass,,,8 in. Concrete Block Basement Wall,Typical Carpet Pad,,,, -Typical Unisulated Carpeted 6in Slab Floor,GroundContactFloor,Mass,,,6 in. Normalweight Concrete Floor,Typical Carpet Pad,,,, -Typical Insulated Basement Mass Wall,GroundContactWall,Mass,Typical Insulation,,Typical Insulation,8 in. Concrete Block Basement Wall,,,, -Typical Uninsulated Basement Mass Wall,GroundContactWall,Mass,,,8 in. Concrete Block Basement Wall,,,,, -ceiling_Metal roof,InteriorCeiling,,,,Metal Standing Seam - 1/16 in.,ceiling_2_Insulation,,,, -int_slab_ceiling_smallhotel,InteriorCeiling,,,,CP02 CARPET PAD,4 in. Normalweight Concrete Floor,,,, -LargeHotel Interior Ceiling,InteriorCeiling,,,,CP02 CARPET PAD,100mm Normalweight concrete floor,Nonres_Floor_Insulation,G01 13mm gypsum board,, -NACM_Drop Ceiling,InteriorCeiling,,,,Acoustic Ceiling,,,,, -Plenum Acoustical Tile,InteriorCeiling,,,,Acoustic Tile - 1/2 in.,,,,, -Typical Interior Ceiling,InteriorCeiling,,,,CP02 CARPET PAD,100mm Normalweight concrete floor,,,, -Typical Interior Door,InteriorDoor,,,,G05 25mm wood,,,,, -int_slab_floor_smallhotel,InteriorFloor,,,,4 in. Normalweight Concrete Floor,CP02 CARPET PAD,,,, -LargeHotel Interior Floor,InteriorFloor,,,,G01 13mm gypsum board,Nonres_Floor_Insulation,100mm Normalweight concrete floor,CP02 CARPET PAD,, -NACM_Interior Floor,InteriorFloor,,,,NACM_Carpet 3/4in,,,,, -Typical Interior Floor,InteriorFloor,,,,100mm Normalweight concrete floor,CP02 CARPET PAD,,,, -Typical Interior Slab Floor,InteriorFloor,Mass,,,4 in. Normalweight Concrete Floor,Typical Carpet Pad,,,, -Typical Interior Partition,InteriorPartition,,,,G05 25mm wood,,,,, -Uninsulated Steel Stud Wall,InteriorPartition,SteelFramed,,,Metal Framed Wall - 24inOC - 2x4 - R0 ins.,,,,, -int_wall_smallhotel,InteriorWall,,,,1/2 in. Gypsum Board,1/2 in. Gypsum Board,,,, -LargeHotel Interior Wall,InteriorWall,,,,G01 13mm gypsum board,G01 13mm gypsum board,,,, -NACM_Interior Wall,InteriorWall,,,,NACM_Gypsum Board 5/8in,NACM_Gypsum Board 5/8in,,,, -Typical Insulated Interior Wall,InteriorWall,WoodFramed,Typical Insulation,,25mm Stucco,5/8 in. Gypsum Board,Typical Insulation,Steel Frame/Cavity,5/8 in. Gypsum Board, -Typical Interior Wall,InteriorWall,,,,G01 13mm gypsum board,G01 13mm gypsum board,,,, -Typical Uninsulated Interior Wall,InteriorWall,WoodFramed,,,1/2 in. Gypsum Board,1/2 in. Gypsum Board,,,, -Typical Interior Window,InteriorWindow,,,,CLEAR 3MM,,,,, -U 0.58 SHGC 0.19 Simple Glazing Skylight,Skylight,Glass with Curb,,,U 0.58 SHGC 0.19 Simple Glazing,,,,, -U 0.58 SHGC 0.36 Simple Glazing Skylight,Skylight,Glass with Curb,,,U 0.58 SHGC 0.36 Simple Glazing,,,,, -U 1.98 SHGC 0.61 Simple Glazing Skylight,Skylight,Glass with Curb,,,U 1.98 SHGC 0.61 Simple Glazing,,,,, -Window_U_0.50_SHGC_0.40_Skylight_Frame_Width_0.000_in,Skylight,,,Skylight_Frame_Width_0.000_in,Glass_2052_LayerAvg,Gap_1_W_0_0038,Glass_2027F_LayerAvg,,, -Window_U_0.50_SHGC_0.40_Skylight_Frame_Width_0.334_in,Skylight,,,Skylight_Frame_Width_0.334_in,Glass_2052_LayerAvg,Gap_1_W_0_0038,Glass_2027F_LayerAvg,,, -Window_U_0.50_SHGC_0.40_Skylight_Frame_Width_0.430_in,Skylight,,,Skylight_Frame_Width_0.430_in,Glass_2052_LayerAvg,Gap_1_W_0_0038,Glass_2027F_LayerAvg,,, -Window_U_0.55_SHGC_0.35_Skylight_Frame_Width_0.709_in,Skylight,,,Skylight_Frame_Width_0.709_in,Glass_2052_LayerAvg,Gap_1_W_0_0038,Glass_2027F_LayerAvg,,, -Window_U_0.65_SHGC_0.35_Skylight_Frame_Width_2.339_in,Skylight,,,Skylight_Frame_Width_2.339_in,Glass_2052_LayerAvg,Gap_1_W_0_0024,Glass_2027F_LayerAvg,,, -Window_U_0.75_SHGC_0.35_Skylight_Frame_Width_2.339_in,Skylight,,,Skylight_Frame_Width_2.339_in,Glass_2052_LayerAvg,Gap_1_W_0_0018,Glass_2027F_LayerAvg,,, -U 0.60 SHGC 0.25 Dbl 2.5mm air,,,,,Glass_2175_LayerAvg,Gap_1_W_0_0025,Glass_2022F_LayerAvg,,, -U 0.61 SHGC 0.77 Simple Glazing Skylight,,,,,U 0.61 SHGC 0.77 Simple Glazing,,,,, -U 0.65 SHGC 0.35 Simple Glazing Skylight,,,,,U 0.65 SHGC 0.35 Simple Glazing,,,,, -U 0.69 SHGC 0.19 Simple Glazing Skylight,,,,,U 0.69 SHGC 0.19 Simple Glazing,,,,, -U 0.69 SHGC 0.36 Simple Glazing Skylight,,,,,U 0.69 SHGC 0.36 Simple Glazing,,,,, -U 0.69 SHGC 0.39 Simple Glazing Skylight,,,,,U 0.69 SHGC 0.39 Simple Glazing,,,,, -U 0.69 SHGC 0.49 Simple Glazing Skylight,,,,,U 0.69 SHGC 0.49 Simple Glazing,,,,, -U 0.69 SHGC 0.64 Simple Glazing Skylight,,,,,U 0.69 SHGC 0.64 Simple Glazing,,,,, -U 0.69 SHGC 0.68 Simple Glazing Skylight,,,,,U 0.69 SHGC 0.68 Simple Glazing,,,,, -U 0.74 SHGC 0.55 Simple Glazing Skylight,,,,,U 0.74 SHGC 0.55 Simple Glazing,,,,, -U 0.74 SHGC 0.65 Simple Glazing Skylight,,,,,U 0.74 SHGC 0.65 Simple Glazing,,,,, -U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,,U 0.75 SHGC 0.35 Simple Glazing,,,,, -U 0.81 SHGC 0.65 Simple Glazing Skylight,,,,,U 0.81 SHGC 0.65 Simple Glazing,,,,, -U 0.85 SHGC 0.65 Simple Glazing Skylight,,,,,U 0.85 SHGC 0.65 Simple Glazing,,,,, -U 0.87 SHGC 0.58 Simple Glazing Skylight,,,,,U 0.87 SHGC 0.58 Simple Glazing,,,,, -U 0.87 SHGC 0.71 Simple Glazing Skylight,,,,,U 0.87 SHGC 0.71 Simple Glazing,,,,, -U 0.87 SHGC 0.77 Simple Glazing Skylight,,,,,U 0.87 SHGC 0.77 Simple Glazing,,,,, -U 0.98 SHGC 0.19 Simple Glazing Skylight,,,,,U 0.98 SHGC 0.19 Simple Glazing,,,,, -U 0.98 SHGC 0.36 Simple Glazing Skylight,,,,,U 0.98 SHGC 0.36 Simple Glazing,,,,, -U 1.10 SHGC 0.62 Simple Glazing Skylight,,,,,U 1.10 SHGC 0.62 Simple Glazing,,,,, -U 1.10 SHGC 0.77 Simple Glazing Skylight,,,,,U 1.10 SHGC 0.77 Simple Glazing,,,,, -U 1.15 SHGC 0.77 Simple Glazing Skylight,,,,,U 1.15 SHGC 0.77 Simple Glazing,,,,, -U 1.17 SHGC 0.19 Simple Glazing Skylight,,,,,U 1.17 SHGC 0.19 Simple Glazing,,,,, -U 1.17 SHGC 0.36 Simple Glazing Skylight,,,,,U 1.17 SHGC 0.36 Simple Glazing,,,,, -U 1.17 SHGC 0.39 Simple Glazing Skylight,,,,,U 1.17 SHGC 0.39 Simple Glazing,,,,, -U 1.17 SHGC 0.49 Simple Glazing Skylight,,,,,U 1.17 SHGC 0.49 Simple Glazing,,,,, -U 1.17 SHGC 0.64 Simple Glazing Skylight,,,,,U 1.17 SHGC 0.64 Simple Glazing,,,,, -U 1.17 SHGC 0.68 Simple Glazing Skylight,,,,,U 1.17 SHGC 0.68 Simple Glazing,,,,, -U 1.30 SHGC 0.27 Simple Glazing Skylight,,,,,U 1.30 SHGC 0.27 Simple Glazing,,,,, -U 1.30 SHGC 0.34 Simple Glazing Skylight,,,,,U 1.30 SHGC 0.34 Simple Glazing,,,,, -U 1.30 SHGC 0.62 Simple Glazing Skylight,,,,,U 1.30 SHGC 0.62 Simple Glazing,,,,, -U 1.30 SHGC 0.65 Simple Glazing Skylight,,,,,U 1.30 SHGC 0.65 Simple Glazing,,,,, -U 1.36 SHGC 0.19 Simple Glazing Skylight,,,,,U 1.36 SHGC 0.19 Simple Glazing,,,,, -U 1.36 SHGC 0.36 Simple Glazing Skylight,,,,,U 1.36 SHGC 0.36 Simple Glazing,,,,, -U 1.36 SHGC 0.39 Simple Glazing Skylight,,,,,U 1.36 SHGC 0.39 Simple Glazing,,,,, -U 1.36 SHGC 0.61 Simple Glazing Skylight,,,,,U 1.36 SHGC 0.61 Simple Glazing,,,,, -U 1.70 SHGC 0.36 Simple Glazing Skylight,,,,,U 1.70 SHGC 0.36 Simple Glazing,,,,, -U 1.80 SHGC 0.36 Simple Glazing Skylight,,,,,U 1.80 SHGC 0.36 Simple Glazing,,,,, -U 1.90 SHGC 0.27 Simple Glazing Skylight,,,,,U 1.90 SHGC 0.27 Simple Glazing,,,,, -U 1.90 SHGC 0.34 Simple Glazing Skylight,,,,,U 1.90 SHGC 0.34 Simple Glazing,,,,, -U 1.90 SHGC 0.39 Simple Glazing Skylight,,,,,U 1.90 SHGC 0.39 Simple Glazing,,,,, -U 1.90 SHGC 0.65 Simple Glazing Skylight,,,,,U 1.90 SHGC 0.65 Simple Glazing,,,,, -U 1.98 SHGC 0.16 Simple Glazing Skylight,,,,,U 1.98 SHGC 0.16 Simple Glazing,,,,, -U 1.98 SHGC 0.19 Simple Glazing Skylight,,,,,U 1.98 SHGC 0.19 Simple Glazing,,,,, -U 1.98 SHGC 0.36 Simple Glazing Skylight,,,,,U 1.98 SHGC 0.36 Simple Glazing,,,,, -U 1.98 SHGC 0.39 Simple Glazing Skylight,,,,,U 1.98 SHGC 0.39 Simple Glazing,,,,, -U 0.49 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.49 SHGC 0.22 Simple Glazing,,,,, -U 0.57 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.57 SHGC 0.25 Simple Glazing,,,,, -U 0.53 SHGC 0.25 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.53 SHGC 0.25 Simple Glazing,,,,, -U 0.48 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.48 SHGC 0.25 Simple Glazing,,,,, -U 0.38 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.38 SHGC 0.36 Simple Glazing,,,,, -U 0.38 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.38 SHGC 0.38 Simple Glazing,,,,, -U 0.36 SHGC 0.4 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.36 SHGC 0.4 Simple Glazing,,,,, -U 0.33 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.33 SHGC 0.45 Simple Glazing,,,,, -U 0.29 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.29 SHGC 0.45 Simple Glazing,,,,, -U 0.5 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.5 SHGC 0.22 Simple Glazing,,,,, -U 0.54 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.54 SHGC 0.25 Simple Glazing,,,,, -U 0.49 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.49 SHGC 0.25 Simple Glazing,,,,, -U 0.45 SHGC 0.25 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.45 SHGC 0.25 Simple Glazing,,,,, -U 1.19 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 1.19 SHGC 0.45 Simple Glazing,,,,, -U 0.73 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.73 SHGC 0.45 Simple Glazing,,,,, -U 0.62 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.62 SHGC 0.45 Simple Glazing,,,,, -U 0.51 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.51 SHGC 0.45 Simple Glazing,,,,, -U 0.38 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.38 SHGC 0.45 Simple Glazing,,,,, -U 0.53 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.53 SHGC 0.22 Simple Glazing,,,,, -U 0.53 SHGC 0.23 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.53 SHGC 0.23 Simple Glazing,,,,, -U 0.38 SHGC 0.35 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.38 SHGC 0.35 Simple Glazing,,,,, -U 0.38 SHGC 0.37 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.38 SHGC 0.37 Simple Glazing,,,,, -U 0.36 SHGC 0.37 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.36 SHGC 0.37 Simple Glazing,,,,, -U 0.31 SHGC 0.39 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.31 SHGC 0.39 Simple Glazing,,,,, -U 0.28 SHGC 0.39 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.28 SHGC 0.39 Simple Glazing,,,,, -U 0.51 SHGC 0.22 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.51 SHGC 0.22 Simple Glazing,,,,, -U 0.51 SHGC 0.23 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.51 SHGC 0.23 Simple Glazing,,,,, -U 0.46 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.46 SHGC 0.25 Simple Glazing,,,,, -U 0.43 SHGC 0.25 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.43 SHGC 0.25 Simple Glazing,,,,, -U 0.36 SHGC 0.36 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.36 SHGC 0.36 Simple Glazing,,,,, -U 0.36 SHGC 0.38 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.36 SHGC 0.38 Simple Glazing,,,,, -U 0.34 SHGC 0.38 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.34 SHGC 0.38 Simple Glazing,,,,, -U 0.29 SHGC 0.4 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.29 SHGC 0.4 Simple Glazing,,,,, -U 0.26 SHGC 0.4 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.26 SHGC 0.4 Simple Glazing,,,,, -U 0.37 SHGC 0.36 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.37 SHGC 0.36 Simple Glazing,,,,, -U 0.37 SHGC 0.38 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.37 SHGC 0.38 Simple Glazing,,,,, -U 0.35 SHGC 0.38 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.35 SHGC 0.38 Simple Glazing,,,,, -U 0.3 SHGC 0.4 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.3 SHGC 0.4 Simple Glazing,,,,, -U 0.27 SHGC 0.4 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.27 SHGC 0.4 Simple Glazing,,,,, -U 0.5 SHGC 0.23 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.5 SHGC 0.23 Simple Glazing,,,,, -U 0.42 SHGC 0.25 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.42 SHGC 0.25 Simple Glazing,,,,, -U 0.47 SHGC 0.25 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.47 SHGC 0.25 Simple Glazing,,,,, -U 1.2 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 1.2 SHGC 0.45 Simple Glazing,,,,, -U 0.5 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.5 SHGC 0.45 Simple Glazing,,,,, -U 0.39 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.39 SHGC 0.45 Simple Glazing,,,,, -U 0.36 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.36 SHGC 0.45 Simple Glazing,,,,, -U 0.75 SHGC 0.35 Simple Glazing Window,Skylight,Weighted,,,U 0.75 SHGC 0.35 Simple Glazing Window,,,,, -U 0.65 SHGC 0.35 Simple Glazing Window,Skylight,Weighted,,,U 0.65 SHGC 0.35 Simple Glazing Window,,,,, -U 0.55 SHGC 0.35 Simple Glazing Window,Skylight,Weighted,,,U 0.55 SHGC 0.35 Simple Glazing,,,,, -U 0.5 SHGC 0.4 Simple Glazing Window,Skylight,Weighted,,,U 0.5 SHGC 0.4 Simple Glazing,,,,, -U 0.5 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 0.5 SHGC 0.55 Simple Glazing,,,,, -U 0.41 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 0.41 SHGC 0.55 Simple Glazing,,,,, -U 1.8 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 1.8 SHGC 0.55 Simple Glazing,,,,, -U 1.7 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 1.7 SHGC 0.55 Simple Glazing,,,,, -U 1.15 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 1.15 SHGC 0.55 Simple Glazing,,,,, -U 0.98 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 0.98 SHGC 0.55 Simple Glazing,,,,, -U 0.85 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 0.85 SHGC 0.55 Simple Glazing,,,,, -U 0.7 SHGC 0.3 Simple Glazing Window,Skylight,Weighted,,,U 0.7 SHGC 0.3 Simple Glazing,,,,, -U 0.65 SHGC 0.3 Simple Glazing Window,Skylight,Weighted,,,U 0.65 SHGC 0.3 Simple Glazing,,,,, -U 0.55 SHGC 0.3 Simple Glazing Window,Skylight,Weighted,,,U 0.55 SHGC 0.3 Simple Glazing,,,,, -U 0.47 SHGC 0.4 Simple Glazing Window,Skylight,Weighted,,,U 0.47 SHGC 0.4 Simple Glazing,,,,, -U 0.44 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 0.44 SHGC 0.55 Simple Glazing,,,,, -U 0.9 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 0.9 SHGC 0.55 Simple Glazing,,,,, -U 0.75 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 0.75 SHGC 0.55 Simple Glazing,,,,, -U 0.37 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.37 SHGC 0.25 Simple Glazing,,,,, -U 0.83 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.83 SHGC 0.25 Simple Glazing,,,,, -U 0.77 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.77 SHGC 0.25 Simple Glazing,,,,, -U 0.93 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.93 SHGC 0.45 Simple Glazing,,,,, -U 0.83 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.83 SHGC 0.45 Simple Glazing,,,,, -U 0.65 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 0.65 SHGC 0.55 Simple Glazing,,,,, -U 1.8 SHGC 0.77 Simple Glazing Skylight,Skylight,Weighted,,,U 1.8 SHGC 0.77 Simple Glazing,,,,, -U 0.65 SHGC 0.77 Simple Glazing Skylight,Skylight,Weighted,,,U 0.65 SHGC 0.77 Simple Glazing,,,,, -U 1.8 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 1.8 SHGC 0.55 Simple Glazing,,,,, -U 0.65 SHGC 0.68 Simple Glazing Skylight,Skylight,Weighted,,,U 0.65 SHGC 0.68 Simple Glazing,,,,, -U 1.8 SHGC 0.64 Simple Glazing Skylight,Skylight,Weighted,,,U 1.8 SHGC 0.64 Simple Glazing,,,,, -U 0.33 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.33 SHGC 0.25 Simple Glazing,,,,, -U 0.68 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.68 SHGC 0.25 Simple Glazing,,,,, -U 0.87 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.87 SHGC 0.45 Simple Glazing,,,,, -U 0.77 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.77 SHGC 0.45 Simple Glazing,,,,, -U 0.55 SHGC 0.64 Simple Glazing Skylight,Skylight,Weighted,,,U 0.55 SHGC 0.64 Simple Glazing,,,,, -U 0.55 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 0.55 SHGC 0.55 Simple Glazing,,,,, -U 1.7 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 1.7 SHGC 0.55 Simple Glazing,,,,, -U 0.31 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.31 SHGC 0.36 Simple Glazing,,,,, -U 0.68 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.68 SHGC 0.36 Simple Glazing,,,,, -U 0.5 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 0.5 SHGC 0.55 Simple Glazing,,,,, -U 1.15 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 1.15 SHGC 0.55 Simple Glazing,,,,, -U 0.31 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.31 SHGC 0.38 Simple Glazing,,,,, -U 0.68 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.68 SHGC 0.38 Simple Glazing,,,,, -U 0.45 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.45 SHGC 0.45 Simple Glazing,,,,, -U 0.5 SHGC 0.36 Simple Glazing Skylight,Skylight,Weighted,,,U 0.5 SHGC 0.36 Simple Glazing,,,,, -U 0.5 SHGC 0.19 Simple Glazing Skylight,Skylight,Weighted,,,U 0.5 SHGC 0.19 Simple Glazing,,,,, -U 0.98 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 0.98 SHGC 0.55 Simple Glazing,,,,, -U 0.5 SHGC 0.34 Simple Glazing Skylight,Skylight,Weighted,,,U 0.5 SHGC 0.34 Simple Glazing,,,,, -U 0.98 SHGC 0.27 Simple Glazing Skylight,Skylight,Weighted,,,U 0.98 SHGC 0.27 Simple Glazing,,,,, -U 0.68 SHGC 0.4 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.68 SHGC 0.4 Simple Glazing,,,,, -U 0.85 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 0.85 SHGC 0.55 Simple Glazing,,,,, -U 0.85 SHGC 0.19 Simple Glazing Skylight,Skylight,Weighted,,,U 0.85 SHGC 0.19 Simple Glazing,,,,, -U 0.85 SHGC 0.39 Simple Glazing Skylight,Skylight,Weighted,,,U 0.85 SHGC 0.39 Simple Glazing,,,,, -U 0.28 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.28 SHGC 0.45 Simple Glazing,,,,, -U 0.68 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.68 SHGC 0.45 Simple Glazing,,,,, -U 0.32 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.32 SHGC 0.45 Simple Glazing,,,,, -U 0.5 SHGC 0.27 Simple Glazing Skylight,Skylight,Weighted,,,U 0.5 SHGC 0.27 Simple Glazing,,,,, -U 0.25 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.25 SHGC 0.45 Simple Glazing,,,,, -U 0.5 SHGC 0.39 Simple Glazing Skylight,Skylight,Weighted,,,U 0.5 SHGC 0.39 Simple Glazing,,,,, -U 0.5 SHGC 0.65 Simple Glazing Skylight,Skylight,Weighted,,,U 0.5 SHGC 0.65 Simple Glazing,,,,, -U 0.85 SHGC 0.27 Simple Glazing Skylight,Skylight,Weighted,,,U 0.85 SHGC 0.27 Simple Glazing,,,,, -U 0.5 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.5 SHGC 0.25 Simple Glazing,,,,, -U 1.1 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 1.1 SHGC 0.25 Simple Glazing,,,,, -U 1.1 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 1.1 SHGC 0.45 Simple Glazing,,,,, -U 0.75 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 0.75 SHGC 0.55 Simple Glazing,,,,, -U 0.75 SHGC 0.49 Simple Glazing Skylight,Skylight,Weighted,,,U 0.75 SHGC 0.49 Simple Glazing,,,,, -U 1.8 SHGC 0.49 Simple Glazing Skylight,Skylight,Weighted,,,U 1.8 SHGC 0.49 Simple Glazing,,,,, -U 0.75 SHGC 0.39 Simple Glazing Skylight,Skylight,Weighted,,,U 0.75 SHGC 0.39 Simple Glazing,,,,, -U 0.75 SHGC 0.68 Simple Glazing Skylight,Skylight,Weighted,,,U 0.75 SHGC 0.68 Simple Glazing,,,,, -U 0.75 SHGC 0.64 Simple Glazing Skylight,Skylight,Weighted,,,U 0.75 SHGC 0.64 Simple Glazing,,,,, -U 0.77 SHGC 0.23 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.77 SHGC 0.23 Simple Glazing,,,,, -U 0.68 SHGC 0.23 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.68 SHGC 0.23 Simple Glazing,,,,, -U 0.63 SHGC 0.33 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.63 SHGC 0.33 Simple Glazing,,,,, -U 0.63 SHGC 0.34 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.63 SHGC 0.34 Simple Glazing,,,,, -U 0.63 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.63 SHGC 0.36 Simple Glazing,,,,, -U 0.63 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.63 SHGC 0.45 Simple Glazing,,,,, -U 0.55 SHGC 0.35 Simple Glazing Skylight,Skylight,,,,U 0.55 SHGC 0.35 Simple Glazing,,,,, -U 0.5 SHGC 0.4 Simple Glazing Skylight,Skylight,,,,U 0.5 SHGC 0.4 Simple Glazing,,,,, -U 0.41 SHGC 0.55 Simple Glazing Skylight,Skylight,,,,U 0.41 SHGC 0.55 Simple Glazing,,,,, -U 0.6 SHGC 0.23 Simple Glazing Window,ExteriorWindow,,,,U 0.6 SHGC 0.23 Simple Glazing,,,,, -U 0.65 SHGC 0.3 Simple Glazing Skylight,Skylight,,,,U 0.65 SHGC 0.3 Simple Glazing,,,,, -U 0.55 SHGC 0.3 Simple Glazing Skylight,Skylight,,,,U 0.55 SHGC 0.3 Simple Glazing,,,,, -U 0.47 SHGC 0.4 Simple Glazing Skylight,Skylight,,,,U 0.47 SHGC 0.4 Simple Glazing,,,,, -U 0.44 SHGC 0.55 Simple Glazing Skylight,Skylight,,,,U 0.44 SHGC 0.55 Simple Glazing,,,,, -U 0.83 SHGC 0.21 Simple Glazing Window,ExteriorWindow,,,,U 0.83 SHGC 0.21 Simple Glazing,,,,, -U 0.7 SHGC 0.3 Simple Glazing Skylight,Skylight,,,,U 0.7 SHGC 0.3 Simple Glazing,,,,, -U 0.32 SHGC 0.22 Simple Glazing Window,ExteriorWindow,,,,U 0.32 SHGC 0.22 Simple Glazing,,,,, -U 0.83 SHGC 0.22 Simple Glazing Window,ExteriorWindow,,,,U 0.83 SHGC 0.22 Simple Glazing,,,,, -U 0.83 SHGC 0.2 Simple Glazing Window,ExteriorWindow,,,,U 0.83 SHGC 0.2 Simple Glazing,,,,, -U 0.62 SHGC 0.2 Simple Glazing Window,ExteriorWindow,,,,U 0.62 SHGC 0.2 Simple Glazing,,,,, -U 1.22 SHGC 0.19 Simple Glazing Window,ExteriorWindow,,,,U 1.22 SHGC 0.19 Simple Glazing,,,,, -U 1.22 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 1.22 SHGC 0.45 Simple Glazing,,,,, -U 1.22 SHGC 0.17 Simple Glazing Window,ExteriorWindow,,,,U 1.22 SHGC 0.17 Simple Glazing,,,,, -U 1.22 SHGC 0.39 Simple Glazing Window,ExteriorWindow,,,,U 1.22 SHGC 0.39 Simple Glazing,,,,, -U 0.98 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.98 SHGC 0.45 Simple Glazing,,,,, -U 1.98 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 1.98 SHGC 0.45 Simple Glazing,,,,, -U 0.57 SHGC 0.39 Simple Glazing Window,ExteriorWindow,,,,U 0.57 SHGC 0.39 Simple Glazing,,,,, -U 0.46 SHGC 0.19 Simple Glazing Window,ExteriorWindow,,,,U 0.46 SHGC 0.19 Simple Glazing,,,,, -U 1.98 SHGC 0.34 Simple Glazing Skylight,Skylight,,,,U 1.98 SHGC 0.34 Simple Glazing,,,,, -U 1.22 SHGC 0.61 Simple Glazing Window,ExteriorWindow,,,,U 1.22 SHGC 0.61 Simple Glazing,,,,, -U 1.22 SHGC 0.34 Simple Glazing Window,ExteriorWindow,,,,U 1.22 SHGC 0.34 Simple Glazing,,,,, -U 0.57 SHGC 0.49 Simple Glazing Window,ExteriorWindow,,,,U 0.57 SHGC 0.49 Simple Glazing,,,,, -U 0.46 SHGC 0.26 Simple Glazing Window,ExteriorWindow,,,,U 0.46 SHGC 0.26 Simple Glazing,,,,, -U 0.98 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 0.98 SHGC 0.45 Simple Glazing,,,,, -U 1.98 SHGC 0.65 Simple Glazing Skylight,Skylight,,,,U 1.98 SHGC 0.65 Simple Glazing,,,,, -U 0.58 SHGC 0.61 Simple Glazing Skylight,Skylight,,,,U 0.58 SHGC 0.61 Simple Glazing,,,,, -U 0.46 SHGC 0.36 Simple Glazing Window,ExteriorWindow,,,,U 0.46 SHGC 0.36 Simple Glazing,,,,, -U 0.46 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.46 SHGC 0.45 Simple Glazing,,,,, -U 0.35 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.35 SHGC 0.45 Simple Glazing,,,,, -U 0.98 SHGC 0.62 Simple Glazing Skylight,Skylight,,,,U 0.98 SHGC 0.62 Simple Glazing,,,,, -U 0.58 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 0.58 SHGC 0.45 Simple Glazing,,,,, -U 0.75 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.75 SHGC 0.25 Simple Glazing,,,,, -U 0.7 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.7 SHGC 0.25 Simple Glazing,,,,, -U 1.98 SHGC 0.49 Simple Glazing Skylight,Skylight,,,,U 1.98 SHGC 0.49 Simple Glazing,,,,, -U 0.65 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.65 SHGC 0.25 Simple Glazing,,,,, -U 0.6 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.6 SHGC 0.25 Simple Glazing,,,,, -U 0.9 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.9 SHGC 0.25 Simple Glazing,,,,, -U 1.98 SHGC 0.71 Simple Glazing Skylight,Skylight,,,,U 1.98 SHGC 0.71 Simple Glazing,,,,, -U 0.4 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.4 SHGC 0.4 Simple Glazing,,,,, -U 0.55 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.55 SHGC 0.4 Simple Glazing,,,,, -U 0.85 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.85 SHGC 0.4 Simple Glazing,,,,, -U 0.35 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.35 SHGC 0.4 Simple Glazing,,,,, -U 0.45 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.45 SHGC 0.4 Simple Glazing,,,,, -U 0.8 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.8 SHGC 0.4 Simple Glazing,,,,, -U 0.65 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.65 SHGC 0.45 Simple Glazing,,,,, -U 0.6 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.6 SHGC 0.45 Simple Glazing,,,,, -U 0.9 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.9 SHGC 0.45 Simple Glazing,,,,, -U 0.4 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.4 SHGC 0.45 Simple Glazing,,,,, -U 0.8 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.8 SHGC 0.45 Simple Glazing,,,,, -U 1.2 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 1.2 SHGC 0.25 Simple Glazing,,,,, -U 1.98 SHGC 0.27 Simple Glazing Skylight,Skylight,,,,U 1.98 SHGC 0.27 Simple Glazing,,,,, -U 1.17 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 1.17 SHGC 0.45 Simple Glazing,,,,, -U 0.98 SHGC 0.49 Simple Glazing Skylight,Skylight,,,,U 0.98 SHGC 0.49 Simple Glazing,,,,, -U 0.98 SHGC 0.46 Simple Glazing Skylight,Skylight,,,,U 0.98 SHGC 0.46 Simple Glazing,,,,, -U 0.58 SHGC 0.65 Simple Glazing Skylight,Skylight,,,,U 0.58 SHGC 0.65 Simple Glazing,,,,, -U 0.58 SHGC 0.55 Simple Glazing Skylight,Skylight,,,,U 0.58 SHGC 0.55 Simple Glazing,,,,, -U 0.4 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.4 SHGC 0.25 Simple Glazing,,,,, -U 0.65 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 0.65 SHGC 0.45 Simple Glazing,,,,, -U 0.35 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.35 SHGC 0.25 Simple Glazing,,,,, -U 0.55 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 0.55 SHGC 0.45 Simple Glazing,,,,, -U 0.42 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.42 SHGC 0.4 Simple Glazing,,,,, -U 0.77 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.77 SHGC 0.4 Simple Glazing,,,,, -U 0.81 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.81 SHGC 0.45 Simple Glazing,,,,, -U 0.5 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 0.5 SHGC 0.45 Simple Glazing,,,,, -U 0.32 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.32 SHGC 0.4 Simple Glazing,,,,, -U 0.7 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.7 SHGC 0.45 Simple Glazing,,,,, -U 0.59 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.59 SHGC 0.45 Simple Glazing,,,,, -U 0.44 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.44 SHGC 0.45 Simple Glazing,,,,, -U 0.93 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.93 SHGC 0.25 Simple Glazing,,,,, -U 0.75 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 0.75 SHGC 0.45 Simple Glazing,,,,, -U 0.3 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.3 SHGC 0.4 Simple Glazing,,,,, -U 0.36 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.36 SHGC 0.4 Simple Glazing,,,,, -U 0.9 SHGC 0.55 Simple Glazing Skylight,Skylight,,,,U 0.9 SHGC 0.55 Simple Glazing,,,,, -U 0.48 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.48 SHGC 0.45 Simple Glazing,,,,, diff --git a/data/openstudio_standards_data/initial_data/support_electric_equipment_space_type_name_tags.csv b/data/openstudio_standards_data/initial_data/support_electric_equipment_space_type_name_tags.csv deleted file mode 100644 index 6cc1ce0e8f..0000000000 --- a/data/openstudio_standards_data/initial_data/support_electric_equipment_space_type_name_tags.csv +++ /dev/null @@ -1,155 +0,0 @@ -support_electric_equipment_space_type_name_tags -corridor - all other -dining - all other -electrical/mechanical -kitchen -laboratory -lobby - all other -locker room -lounge/breakroom - all other -office - enclosed <= 250 sf -office - enclosed > 250 sf -office - open -restroom - all other -stairwell -storage < 50 sf - all other -storage 50 to 1000 sf - all other -vehicular maintenance -atrium - first three floors -audience seating - convention center -classroom/lecture/training - all other -conference/meeting/multipurpose -exhibit - convention center -gymnasium exercise area -gymnasium playing area -laundry/washing -lobby - elevator -nurses station -post office - sorting area -"sports arena playing area, class IV" -audience seating - all other -confinement cells -judges chambers -library - stacks -storage - inactive -dining - bar/lounge/leisure -dining - cafeteria/fast food -dining - family -computer room -dormitory - living quarters -audience seating - exercise center -exam/treatment -library - reading -emergency vehicle garage -firestation - sleeping quarters -"parking area, interior" -audience seating - gymnasium -emergency room -patient room -corridor - hospital -fellowship hall - religious facility -lounge/breakroom - healthcare facility -operating room -physical therapy -storage < 50 sf - hospital -storage 50 to 1000 sf - hospital -guest room -lobby - hotel -library - cataloging -museum exhibit area -corridor - manufacturing facility -manufacturing equipment room -manufacturing low bay -performing arts dressing room -audience seating - auditorium -audience seating - motion picture theater -lobby - motion picture theater -Dwelling Unit -museum restoration -banking activity -warehouse - fine storage -classroom/lecture/training - penitentiary -dining - penitentiary -audience seating - performing arts theater -lobby - performing arts theater -audience seating - religious facility -worship/pulpit/choir area -classroom/lecture/training - preschool to 12th -"sports arena playing area, class II" -audience seating - sports arena -airport concourse -atrium < 20 ft height -atrium > 40 ft height -atrium >= 20 ft and <= 40 ft in height -baggage/carousel -"seating area, general" -transportation ticket counter -warehouse - bulk storage -workshop -gymnasium_playing_area -gymnasium_exercise_area -courtroom -confinement_cells -judges_chambers -emergency_vehicle_garage -firestation_sleeping_quarters -post_office_sorting_area -exhibit_convention_center -library_cataloging -library_stacks -library_reading -emergency_room -recovery -nurses_station -exam_treatment -pharmacy -patient_room -operating_room -nursery -medical_supply -physical_therapy -imaging -laundry_washing -automotive -manufacturing_low_bay -manufacturing_high_bay -detailed_manufacuring -manufacturing_equipment_room -manufacturing_control -manufacturing_extra_high_bay -guest_room -dormitory_living_quarters -museum_exhibit_area -museum_restoration -banking_activity -worship_pulpit_choir_area -fellowship_hall_religious_facility -sales -retail_mall_concourse -retail_dressing_room -sports_arena_ring_sports_area -sports_arena_court_sports_area -sports_arena_indoor_playing_field -sports_arena_playing_area_class_I -sports_arena_playing_area_class_II -sports_arena_playing_area_class_III -sports_arena_playing_area_class_IV -warehouse_fine_storage -warehouse_bulk_storage -parking_area_interior -airport_concourse -baggage_carousel -transportation_ticket_counter -sales_display_type_1 -sales_display_type_2 -sales_display_type_3 -sales_display_type_4 -breakroom -copy_print -computer_room -loading_dock -locker_room -seating_area_general -vehicular_maintenance -chapel_visually_impaired -recreation_common_living_visually_impaired diff --git a/data/openstudio_standards_data/initial_data/support_lighting_space_type_name_tags.csv b/data/openstudio_standards_data/initial_data/support_lighting_space_type_name_tags.csv deleted file mode 100644 index aa285798d8..0000000000 --- a/data/openstudio_standards_data/initial_data/support_lighting_space_type_name_tags.csv +++ /dev/null @@ -1,159 +0,0 @@ -lighting_space_type_name -bam_automotive_facility -bam_convention_center -bam_courthouse -bam_dinin_bar_lounge_leisure -bam_dining_cafeteria_fast_food -bam_dining_family -bam_dormitory -bam_exercise_center -bam_fire_station -bam_gymnasium -bam_healthcare_clinic -bam_hospital -bam_hotel -bam_library -bam_manufacturing_facility -bam_motel -bam_motion_picture_theater -bam_multifamily -bam_museum -bam_office -bam_parking_garage -bam_penitentiary -bam_performing_arts_theater -bam_police_station -bam_post_office -bam_religious_facility -bam_retail -bam_school_university -bam_sports_arena -bam_town_hall -bam_transportation -bam_warehouse -bam_workshop -office_enclosed_small -office_enclosed_large -office_open -conference_meeting_multipurpose -classroom_lecture_training_general -classroom_lecture_training_penitentiary -lobby_general -lobby_hotel -lobby_performing_arts_theater -lobby_motion_picture_theater -lobby_visually_impaired -lobby_elevator -audience_seating_general -audience_seating_gymnasium -audience_seating_exercise_center -audience_seating_convention_center -audience_seating_penitentiary -audience_seating_religious_facility -audience_seating_sports_arena -audience_seating_performing_arts_theater -audience_seating_motion_picture_theater -audience_seating_transportation -audience_seating_auditorium -atrium_first_three_floor -atrium_each_additional_floor -atrium_low -atrium_medium -atrium_high -lounge_breakroom_general -lounge_breakroom_healthcare_facility -dining_general -dining_penitentiary -dining_hotel -dining_motel -dining_bar_lounge_leisure -dining_family -dining_cafeteria_fast_food -dining_visually_impaired -kitchen -laboratory_classroom -laboratory_all_other -restroom_visually_impaired -restroom_all_other -performing_arts_dressing_room -corridor_general -corridor_hospital -corridor_manufacturing_facility -corridor_visually_impaired -stairway -stairwell -storage_ all_other_small -storage_ all_other_large -storage_hospital_small -storage_hospital_large -storage_inactive -storage_inactive_museum -electrical_mechanical -workshop -gymnasium_playing_area -gymnasium_exercise_area -courtroom -confinement_cells -judges_chambers -emergency_vehicle_garage -firestation_sleeping_quarters -post_office_sorting_area -exhibit_convention_center -library_cataloging -library_stacks -library_reading -emergency_room -recovery -nurses_station -exam_treatment -pharmacy -patient_room -operating_room -nursery -medical_supply -physical_therapy -imaging -laundry_washing -automotive -manufacturing_low_bay -manufacturing_high_bay -detailed_manufacuring -manufacturing_equipment_room -manufacturing_control -manufacturing_extra_high_bay -guest_room -dormitory_living_quarters -museum_exhibit_area -museum_restoration -banking_activity -worship_pulpit_choir_area -fellowship_hall_religious_facility -sales -retail_mall_concourse -retail_dressing_room -sports_arena_ring_sports_area -sports_arena_court_sports_area -sports_arena_indoor_playing_field -sports_arena_playing_area_class_I -sports_arena_playing_area_class_II -sports_arena_playing_area_class_III -sports_arena_playing_area_class_IV -warehouse_fine_storage -warehouse_bulk_storage -parking_area_interior -airport_concourse -baggage_carousel -transportation_ticket_counter -sales_display_type_1 -sales_display_type_2 -sales_display_type_3 -sales_display_type_4 -breakroom -copy_print -computer_room -loading_dock -locker_room -seating_area_general -vehicular_maintenance -chapel_visually_impaired -recreation_common_living_visually_impaired diff --git a/data/openstudio_standards_data/initial_data/support_materials.csv b/data/openstudio_standards_data/initial_data/support_materials.csv deleted file mode 100644 index 2cf92ec668..0000000000 --- a/data/openstudio_standards_data/initial_data/support_materials.csv +++ /dev/null @@ -1,1390 +0,0 @@ -name,material_type,roughness,thickness,conductivity,resistance,density,specific_heat,thermal_absorptance,solar_absorptance,visible_absorptance,gas_type,u_factor,solar_heat_gain_coefficient,visible_transmittance,optical_data_type,solar_transmittance_at_normal_incidence,front_side_solar_reflectance_at_normal_incidence,back_side_solar_reflectance_at_normal_incidence,visible_transmittance_at_normal_incidence,front_side_visible_reflectance_at_normal_incidence,back_side_visible_reflectance_at_normal_incidence,infrared_transmittance_at_normal_incidence,front_side_infrared_hemispherical_emissivity,back_side_infrared_hemispherical_emissivity,dirt_correction_factor_for_solar_and_visible_transmittance,solar_diffusing,frame_width,annotation -1 Coat Stucco,StandardOpaqueMaterial,MediumRough,0.38,5.0004,0.07599392,115.81,0.2,,,,,,,,,,,,,,,,,,,,, -1/2 in. Gypsum Board,StandardOpaqueMaterial,Smooth,0.5,1.109355488,0.450712153,49.94236846,0.260342027,0.9,0.7,0.5,,,,,,,,,,,,,,,,,, -1/2IN Gypsum,StandardOpaqueMaterial,Smooth,0.5,1.109355488,0.450712153,48.99970626,0.198242094,0.9,0.4,0.4,,,,,,,,,,,,,,,,,, -10 PSF Roof - 1 in.,StandardOpaqueMaterial,VeryRough,1,12.0048,0.083300013,120,0.2,,,,,,,,,,,,,,,,,,,,, -100mm Normalweight concrete floor,StandardOpaqueMaterial,MediumRough,4,16.0194175,0.249696969,144.957816,0.198852772,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -12 in. Normalweight Concrete Floor,StandardOpaqueMaterial,MediumRough,12,16.01631985,0.749235786,144.9577245,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -15 PSF Roof - 1 1/2 in.,StandardOpaqueMaterial,VeryRough,1.5,18.0072,0.083300013,120,0.2,,,,,,,,,,,,,,,,,,,,, -1IN Stucco,StandardOpaqueMaterial,Smooth,0.996062992,4.79657579,0.207661264,115.9911508,0.199914015,0.9,0.7,0.92,,,,,,,,,,,,,,,,,, -25 PSF Roof - 2 1/2 in.,StandardOpaqueMaterial,VeryRough,2.5,30.012,0.083300013,120,0.2,,,,,,,,,,,,,,,,,,,,, -25mm Stucco,StandardOpaqueMaterial,Smooth,1,4.992099695,0.200316512,115.8662948,0.200630553,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -3 Coat Stucco,StandardOpaqueMaterial,MediumRough,0.88,4.3752,0.201133662,116,0.2,,,,,,,,,,,,,,,,,,,,, -4 in. Normalweight Concrete Floor,StandardOpaqueMaterial,MediumRough,4,16.01631985,0.249745262,144.9577245,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -4 in. Normalweight Concrete Wall,StandardOpaqueMaterial,MediumRough,4,16.01631985,0.249745262,144.9577245,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -5 PSF Roof - 1/2 in.,StandardOpaqueMaterial,VeryRough,0.5,6.0024,0.083300013,120,0.2,,,,,,,,,,,,,,,,,,,,, -5/8 in. Gypsum Board,StandardOpaqueMaterial,MediumSmooth,0.625984252,1.109355488,0.56427742,49.94236846,0.260342027,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -5/8 in. Plywood,StandardOpaqueMaterial,Smooth,0.625984252,0.832016616,0.752369893,33.96081055,0.289003535,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -6 in. Heavyweight Concrete Roof,StandardOpaqueMaterial,MediumRough,6,16.01631985,0.374617893,144.9577245,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -6 in. Normalweight Concrete Floor,StandardOpaqueMaterial,MediumRough,6,16.01631985,0.374617893,144.9577245,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -8 in. Concrete Block Basement Wall,StandardOpaqueMaterial,MediumRough,8,9.193783605,0.870153176,114.9923034,0.217827458,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -8 in. Concrete Block Wall,StandardOpaqueMaterial,MediumRough,8,4.992099695,1.602532098,49.94236846,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -8 in. Normalweight Concrete Floor,StandardOpaqueMaterial,MediumRough,8,16.01631985,0.499490524,144.9577245,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -8 in. Normalweight Concrete Wall,StandardOpaqueMaterial,MediumRough,8,16.01631985,0.499490524,144.9577245,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -8IN Concrete HW,StandardOpaqueMaterial,MediumRough,8.003937008,11.99213282,0.667432318,140.0259156,0.199914015,0.9,0.65,0.65,,,,,,,,,,,,,,,,,, -8IN CONCRETE HW RefBldg,StandardOpaqueMaterial,Rough,8,9.089781528,0.880109162,139.8386317,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Acoustic Ceiling,StandardOpaqueMaterial,MediumSmooth,0.5,0.395207893,1.26515692,17.97925265,0.319814656,0.9,0.7,0.2,,,,,,,,,,,,,,,,,, -Acoustic Tile - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,0.3996,1.251251251,18,0.19,,,,,,,,,,,,,,,,,,,,, -Acoustic Tile - 3/4 in.,StandardOpaqueMaterial,MediumSmooth,0.75,0.3996,1.876876877,18,0.19,,,,,,,,,,,,,,,,,,,,, -Acoustic Tile - 3/8 in.,StandardOpaqueMaterial,MediumSmooth,0.38,0.39,0.974358974,18,0.19,,,,,,,,,,,,,,,,,,,,, -Adiabatic Material,MasslessOpaqueMaterial,,,,9999,,,,,,,,,,,,,,,,,,,,,,, -Aggregate - 45 lb/ft3 - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,1.56,0.320512821,45,0.32,,,,,,,,,,,,,,,,,,,,, -Aggregate - 45 lb/ft3 - 5/8 in.,StandardOpaqueMaterial,MediumSmooth,0.63,1.5996,0.393848462,45,0.32,,,,,,,,,,,,,,,,,,,,, -Aggregate - 45 lb/ft3 - on metal lath - 3/4 in.,StandardOpaqueMaterial,MediumSmooth,0.75,1.5996,0.468867217,45,0.32,,,,,,,,,,,,,,,,,,,,, -Aggregate - Perlite - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,1.2996,0.384733764,45,0.32,,,,,,,,,,,,,,,,,,,,, -Aggregate - Perlite - 5/8 in.,StandardOpaqueMaterial,Smooth,0.63,1.5,0.42,45,0.32,,,,,,,,,,,,,,,,,,,,, -Aggregate - Perlite - on metal lath - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,1.7004,0.441072689,45,0.32,,,,,,,,,,,,,,,,,,,,, -Air - Cavity - Wall Roof Ceiling - 4 in. or more,StandardOpaqueMaterial,Smooth,6,6.5196,0.920301859,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Ceiling - 1 1/2 in.,StandardOpaqueMaterial,Smooth,1.5,1.95,0.769230769,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Ceiling - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.6804,0.734861846,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Ceiling - 3 1/2 in.,StandardOpaqueMaterial,Smooth,3.5,4.38,0.799086758,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Ceiling - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,0.9996,0.75030012,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Floor - 1 1/2 in.,StandardOpaqueMaterial,Smooth,1.5,1.5996,0.937734434,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Floor - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.6504,0.768757688,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Floor - 3 1/2 in.,StandardOpaqueMaterial,Smooth,3.5,3.5004,0.999885727,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Floor - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,0.8796,0.8526603,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Metal Wall Framing - 16 or 24 in. OC,StandardOpaqueMaterial,Smooth,5.5,8.46,0.650118203,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Roof - 1 1/2 in.,StandardOpaqueMaterial,Smooth,1.5,1.8804,0.797702616,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Roof - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.66,0.757575758,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Roof - 3 1/2 in.,StandardOpaqueMaterial,Smooth,3.5,4.2696,0.819748923,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Roof - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,0.93,0.806451613,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Wall - 1 1/2 in.,StandardOpaqueMaterial,Smooth,1.5,1.7196,0.872295883,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Wall - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.6504,0.768757688,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Wall - 3 1/2 in.,StandardOpaqueMaterial,Smooth,3.5,4.1196,0.849597048,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Wall - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,0.8904,0.842318059,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -AIR 13MM,Gas,,0.5,,,,,,,,Air,,,,,,,,,,,,,,,,, -AIR 3MM,Gas,,0.125984252,,,,,,,,Air,,,,,,,,,,,,,,,,, -AIR 6MM,Gas,,0.248031496,,,,,,,,Air,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Double glass with no low e - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.9,2.522222222,29.09,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Double glass with no low e - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.8196,3.989751098,20.44,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Double glass with no low e - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,1.08,4.138888889,15.23,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Double glass with no low e - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,1.3296,4.264440433,12.22,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Double glass with no low e - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,1.5996,4.294823706,10.26,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Double glass with no low e - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.8504,4.361219196,8.88,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Double glass with no low e - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.5304,3.450226244,35.69,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Double glass with no low e - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.6696,3.808243728,25.92,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - No Ins.,StandardOpaqueMaterial,Smooth,2.27,1.1796,1.924381146,29.09,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.8496,3.848870056,20.44,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,1.1004,4.062159215,15.23,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,1.35,4.2,12.22,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,1.6104,4.266020864,10.26,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.86,4.338709677,8.88,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.5604,3.265524625,35.69,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.6996,3.644939966,25.92,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Triple or low e glass - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.78,2.91025641,29.09,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Triple or low e glass - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.8196,3.989751098,20.44,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Triple or low e glass - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,1.08,4.138888889,15.23,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Triple or low e glass - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,1.3296,4.264440433,12.22,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Triple or low e glass - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,1.5996,4.294823706,10.26,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Triple or low e glass - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.8504,4.361219196,8.88,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Triple or low e glass - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.51,3.588235294,35.69,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Triple or low e glass - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.6696,3.808243728,25.92,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Double glass with no low e coatings - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.8304,2.733622351,29.09,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Double glass with no low e coatings - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.6504,5.027675277,20.44,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Double glass with no low e coatings - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.8304,5.382947977,15.23,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Double glass with no low e coatings - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,1.00464,5.643812709,12.22,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Double glass with no low e coatings - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,1.1904,5.771169355,10.26,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Double glass with no low e coatings - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.3704,5.888791594,8.88,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Double glass with no low e coatings - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.4404,4.155313351,35.69,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Double glass with no low e coatings - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.54,4.722222222,25.92,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - No Ins.,StandardOpaqueMaterial,Smooth,2.27,1.1304,2.008138712,29.09,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.66,4.954545455,20.44,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.84,5.321428571,15.23,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,1.0104,5.611638955,12.22,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,1.1904,5.771169355,10.26,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.38,5.847826087,8.88,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.4704,3.890306122,35.69,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.5604,4.550321199,25.92,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Triple or low e glass - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.69,3.289855072,29.09,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Triple or low e glass - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.63648,5.137631976,20.44,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Triple or low e glass - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.8196,5.453879941,15.23,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Triple or low e glass - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,0.9996,5.672268908,12.22,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Triple or low e glass - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,1.1796,5.824008138,10.26,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Triple or low e glass - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.3704,5.888791594,8.88,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Triple or low e glass - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.41724,4.385964912,35.69,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Triple or low e glass - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.5304,4.807692308,25.92,0.26,,,,,,,,,,,,,,,,,,,,, -ARGON 13MM,Gas,,0.5,,,,,,,,Argon,,,,,,,,,,,,,,,,, -Asbestos or cement shingles - 3/8 in.,StandardOpaqueMaterial,VeryRough,0.38,1.7904,0.212243074,120,0.24,,,,,,,,,,,,,,,,,,,,, -Ash - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,1.1004,0.908760451,40.06,0.39,,,,,,,,,,,,,,,,,,,,, -Asphalt - bitumen with inert fill - 100 lb/ft3 - 3/4 in.,StandardOpaqueMaterial,VeryRough,0.75,3,0.25,100,0.3,,,,,,,,,,,,,,,,,,,,, -Asphalt - bitumen with inert fill - 144 lb/ft3 - 3/4 in.,StandardOpaqueMaterial,VeryRough,0.75,8.0004,0.093745313,144,0.3,,,,,,,,,,,,,,,,,,,,, -Asphalt roll roofing - 1/4 in.,StandardOpaqueMaterial,VeryRough,0.25,1.6704,0.149664751,70,0.36,,,,,,,,,,,,,,,,,,,,, -Asphalt Shingles,StandardOpaqueMaterial,VeryRough,0.125984252,0.277338872,0.454261067,69.91931585,0.30094583,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Asphalt shingles - 1/4 in.,StandardOpaqueMaterial,VeryRough,0.25,0.5604,0.446109921,69.89,0.3,,,,,,,,,,,,,,,,,,,,, -AtticFloor Insulation,StandardOpaqueMaterial,MediumRough,9.366141732,0.339740118,27.56854794,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Birch - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,1.1904,0.840053763,43.93,0.39,,,,,,,,,,,,,,,,,,,,, -BLUE 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.48,0.05,0.05,0.57,0.06,0.06,0,0.84,0.84,1,FALSE,, -Brick - 48 lb/ft3 - 3 5/8 in.,StandardOpaqueMaterial,Rough,3.63,1.5,2.42,48,0.19,,,,,,,,,,,,,,,,,,,,, -Brick - fired clay - 140 lb/ft3 - 3 5/8 in.,StandardOpaqueMaterial,MediumRough,3.63,8.22,0.441605839,139.78,0.19,,,,,,,,,,,,,,,,,,,,, -BRONZE 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.482,0.054,0.054,0.534,0.057,0.057,0,0.84,0.84,1,FALSE,, -Building Paper - 1/16 in.,StandardOpaqueMaterial,MediumSmooth,0.06,2.0004,0.029994001,70,0.3,,,,,,,,,,,,,,,,,,,,, -Built-up Roofing,StandardOpaqueMaterial,Rough,0.374015748,1.109355488,0.337146886,69.91931585,0.348715009,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Built-up roofing - 3/8 in.,StandardOpaqueMaterial,VeryRough,0.38,1.14,0.333333333,70,0.35,,,,,,,,,,,,,,,,,,,,, -Built-up Roofing - Highly Reflective,StandardOpaqueMaterial,Rough,0.374015748,1.109355488,0.337146886,69.91931585,0.348715009,0.75,0.45,0.7,,,,,,,,,,,,,,,,,, -Bulk Storage Products Material,StandardOpaqueMaterial,Rough,96.0001946,9.998066642,9.601875846,12.49999184,0.199866248,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -California Redwood - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,0.78,1.282051282,26.21,0.39,,,,,,,,,,,,,,,,,,,,, -Carpet - 3/4 in.,StandardOpaqueMaterial,Rough,0.75,0.3156,2.376425856,18,0.33,,,,,,,,,,,,,,,,,,,,, -Carpet - 3/4 in. CBES,StandardOpaqueMaterial,Smooth,0.75,0.34691,,18,0.33,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -ceiling_2_Insulation,StandardOpaqueMaterial,Smooth,3.96766,0.15963,,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 1 1/2 in. R8.8,StandardOpaqueMaterial,Rough,1.5,0.1704,8.802816901,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 1 in. R5.9,StandardOpaqueMaterial,Rough,1,0.1704,5.868544601,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 1/2 in. R2.9,StandardOpaqueMaterial,Rough,0.5,0.1704,2.9342723,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 1/4 in. R1.5,StandardOpaqueMaterial,Rough,0.25,0.1704,1.46713615,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 1/8 in. R0.7,StandardOpaqueMaterial,Rough,0.13,0.1704,0.762910798,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 2 1/2 in. R15,StandardOpaqueMaterial,Rough,2.5,0.1704,14.6713615,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 2 in. R12,StandardOpaqueMaterial,Rough,2,0.1704,11.7370892,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 3 1/2 in. R21,StandardOpaqueMaterial,Rough,3.5,0.1704,20.5399061,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 3 in. R18,StandardOpaqueMaterial,Rough,3,0.1704,17.6056338,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 4 1/2 in. R26,StandardOpaqueMaterial,Rough,4.5,0.1704,26.4084507,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 4 in. R23,StandardOpaqueMaterial,Rough,4,0.1704,23.4741784,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 5 1/2 in. R32,StandardOpaqueMaterial,Rough,5.5,0.1704,32.27699531,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 5 in. R29,StandardOpaqueMaterial,Rough,5,0.1704,29.342723,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 6 1/2 in. R38,StandardOpaqueMaterial,Rough,6.5,0.1704,38.14553991,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 6 in. R35,StandardOpaqueMaterial,Rough,6,0.1704,35.21126761,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Clay - Part Grouted and Empty - 130 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.12,1.923076923,130,0.13,,,,,,,,,,,,,,,,,,,,, -Clay - Part Grouted and Empty - 130 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,3.7596,2.127885945,130,0.13,,,,,,,,,,,,,,,,,,,,, -Clay - Part Grouted and Insulated - 130 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,2.7,2.222222222,130,0.13,,,,,,,,,,,,,,,,,,,,, -Clay - Part Grouted and Insulated - 130 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,3.12,2.564102564,130,0.13,,,,,,,,,,,,,,,,,,,,, -Clay - Solid Grout - 130 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.9,1.538461538,130,0.17,,,,,,,,,,,,,,,,,,,,, -Clay - Solid Grout - 130 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,4.56,1.754385965,130,0.17,,,,,,,,,,,,,,,,,,,,, -Clay tile - 1/2 in.,StandardOpaqueMaterial,MediumRough,0.5,0.1896,2.637130802,85,0.21,,,,,,,,,,,,,,,,,,,,, -Clay tile - hollow - 1 cell deep - 3 in.,StandardOpaqueMaterial,MediumRough,3,3.75,0.8,85,0.21,,,,,,,,,,,,,,,,,,,,, -Clay tile - hollow - 1 cell deep - 4 in.,StandardOpaqueMaterial,MediumRough,4,3.6,1.111111111,85,0.21,,,,,,,,,,,,,,,,,,,,, -Clay tile - hollow - 2 cells deep - 10 in.,StandardOpaqueMaterial,MediumRough,10,4.5,2.222222222,85,0.21,,,,,,,,,,,,,,,,,,,,, -Clay tile - hollow - 2 cells deep - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.9504,1.518833536,85,0.21,,,,,,,,,,,,,,,,,,,,, -Clay tile - hollow - 2 cells deep - 8 in.,StandardOpaqueMaterial,MediumRough,8,4.32,1.851851852,85,0.21,,,,,,,,,,,,,,,,,,,,, -Clay tile - hollow - 3 cells deep - 12 in.,StandardOpaqueMaterial,MediumRough,12,4.8,2.5,85,0.21,,,,,,,,,,,,,,,,,,,,, -Clay Tile - Paver,StandardOpaqueMaterial,MediumRough,0.38,12.504,0.030390275,139.78,0.22,,,,,,,,,,,,,,,,,,,,, -CLEAR 2.5MM,StandardGlazing,,0.098425197,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.8,0.075,0.075,0.901,0.081,0.081,0,0.84,0.84,1,FALSE,, -CLEAR 3MM,StandardGlazing,,0.118110236,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.837,0.075,0.075,0.898,0.081,0.081,0,0.84,0.84,1,FALSE,, -CLEAR 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.775,0.071,0.071,0.881,0.08,0.08,0,0.84,0.84,1,FALSE,, -COATED POLY-55,StandardGlazing,,0.02007874,0.970686052,1.030199206,,,,,,,,,,SpectralAverage,0.32,0.582,0.593,0.551,0.336,0.375,0,0.046,0.72,1,FALSE,, -COATED POLY-77,StandardGlazing,,0.02007874,0.970686052,1.030199206,,,,,,,,,,SpectralAverage,0.504,0.402,0.398,0.766,0.147,0.167,0,0.075,0.72,1,FALSE,, -Compliance Insulation R0.01,StandardOpaqueMaterial,MediumSmooth,0.0016,0.1596,0.010025063,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R0.02,StandardOpaqueMaterial,MediumSmooth,0.0032,0.1596,0.020050125,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R0.10,StandardOpaqueMaterial,MediumSmooth,0.016,0.1596,0.100250627,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R1.35,StandardOpaqueMaterial,MediumSmooth,0.216,0.1596,1.353383459,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R1.41,StandardOpaqueMaterial,MediumSmooth,0.2256,0.1596,1.413533835,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R1.54,StandardOpaqueMaterial,MediumSmooth,0.2464,0.1596,1.543859649,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R10.06,StandardOpaqueMaterial,MediumSmooth,1.6096,0.1596,10.08521303,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R12.55,StandardOpaqueMaterial,MediumSmooth,2.008,0.1596,12.58145363,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R12.69,StandardOpaqueMaterial,MediumSmooth,2.0304,0.1596,12.72180451,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R13.99,StandardOpaqueMaterial,MediumSmooth,2.2384,0.1596,14.02506266,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R14.14,StandardOpaqueMaterial,MediumSmooth,2.2624,0.1596,14.1754386,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R14.32,StandardOpaqueMaterial,MediumSmooth,2.2912,0.1596,14.35588972,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R14.60,StandardOpaqueMaterial,MediumSmooth,2.336,0.1596,14.63659148,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R15.54,StandardOpaqueMaterial,MediumSmooth,2.4864,0.1596,15.57894737,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R16.58,StandardOpaqueMaterial,MediumSmooth,2.6528,0.1596,16.62155388,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R16.69,StandardOpaqueMaterial,MediumSmooth,2.6704,0.1596,16.73182957,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R17.67,StandardOpaqueMaterial,MediumSmooth,2.8272,0.1596,17.71428571,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R19.63,StandardOpaqueMaterial,MediumSmooth,3.1408,0.1596,19.67919799,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R2.15,StandardOpaqueMaterial,MediumSmooth,0.344,0.1596,2.155388471,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R2.19,StandardOpaqueMaterial,MediumSmooth,0.3504,0.1596,2.195488722,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R2.85,StandardOpaqueMaterial,MediumSmooth,0.456,0.1596,2.857142857,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R2.89,StandardOpaqueMaterial,MediumSmooth,0.4624,0.1596,2.897243108,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R20.05,StandardOpaqueMaterial,MediumSmooth,3.208,0.1596,20.10025063,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R21.18,StandardOpaqueMaterial,MediumSmooth,3.3888,0.1596,21.23308271,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R21.39,StandardOpaqueMaterial,MediumSmooth,3.4224,0.1596,21.44360902,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R22.48,StandardOpaqueMaterial,MediumSmooth,3.5968,0.1596,22.53634085,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R24.86,StandardOpaqueMaterial,MediumSmooth,3.9776,0.1596,24.92230576,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R25.16,StandardOpaqueMaterial,MediumSmooth,4.0256,0.1596,25.22305764,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R28.63,StandardOpaqueMaterial,MediumSmooth,4.5808,0.1596,28.70175439,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R3.63,StandardOpaqueMaterial,MediumSmooth,0.5808,0.1596,3.639097744,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R3.70,StandardOpaqueMaterial,MediumSmooth,0.592,0.1596,3.709273183,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R34.93,StandardOpaqueMaterial,MediumSmooth,5.5888,0.1596,35.01754386,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R6.32,StandardOpaqueMaterial,MediumSmooth,1.0112,0.1596,6.335839599,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R6.46,StandardOpaqueMaterial,MediumSmooth,1.0336,0.1596,6.476190476,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R7.10,StandardOpaqueMaterial,MediumSmooth,1.136,0.1596,7.117794486,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R7.18,StandardOpaqueMaterial,MediumSmooth,1.1488,0.1596,7.197994987,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R7.39,StandardOpaqueMaterial,MediumSmooth,1.1824,0.1596,7.408521303,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R8.00,StandardOpaqueMaterial,MediumSmooth,1.28,0.1596,8.020050125,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R8.07,StandardOpaqueMaterial,MediumSmooth,1.2912,0.1596,8.090225564,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R9.83,StandardOpaqueMaterial,MediumSmooth,1.5697,0.1596,9.835213033,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R9.94,StandardOpaqueMaterial,MediumSmooth,1.5904,0.1596,9.964912281,1,0.27,,,,,,,,,,,,,,,,,,,,, -Concrete - 100 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,6.2496,1.600102407,100,0.21,,,,,,,,,,,,,,,,,,,,, -Concrete - 100 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,6.2496,1.920122888,100,0.21,,,,,,,,,,,,,,,,,,,,, -Concrete - 100 lb/ft3 - 2 in.,StandardOpaqueMaterial,MediumRough,2,6.2496,0.320020481,100,0.21,,,,,,,,,,,,,,,,,,,,, -Concrete - 100 lb/ft3 - 4 in.,StandardOpaqueMaterial,MediumRough,4,6.2496,0.640040963,100,0.21,,,,,,,,,,,,,,,,,,,,, -Concrete - 100 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,6.2496,0.960061444,100,0.21,,,,,,,,,,,,,,,,,,,,, -Concrete - 100 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,6.2496,1.280081925,100,0.21,,,,,,,,,,,,,,,,,,,,, -Concrete - 140 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,13.53,0.7390983,139.78,0.22,,,,,,,,,,,,,,,,,,,,, -Concrete - 140 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,13.53,0.88691796,139.78,0.22,,,,,,,,,,,,,,,,,,,,, -Concrete - 140 lb/ft3 - 2 in.,StandardOpaqueMaterial,MediumRough,2,13.53,0.14781966,139.78,0.22,,,,,,,,,,,,,,,,,,,,, -Concrete - 140 lb/ft3 - 4 in.,StandardOpaqueMaterial,MediumRough,4,13.53,0.29563932,139.78,0.22,,,,,,,,,,,,,,,,,,,,, -Concrete - 140 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,13.53,0.44345898,139.78,0.22,,,,,,,,,,,,,,,,,,,,, -Concrete - 140 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,13.53,0.59127864,139.78,0.22,,,,,,,,,,,,,,,,,,,,, -Concrete - 80 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,3.6804,2.717095968,79.87,0.2,,,,,,,,,,,,,,,,,,,,, -Concrete - 80 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,3.6804,3.260515161,79.87,0.2,,,,,,,,,,,,,,,,,,,,, -Concrete - 80 lb/ft3 - 2 in.,StandardOpaqueMaterial,MediumRough,2,3.6804,0.543419194,79.87,0.2,,,,,,,,,,,,,,,,,,,,, -Concrete - 80 lb/ft3 - 4 in.,StandardOpaqueMaterial,MediumRough,4,3.6804,1.086838387,79.87,0.2,,,,,,,,,,,,,,,,,,,,, -Concrete - 80 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.6804,1.630257581,79.87,0.2,,,,,,,,,,,,,,,,,,,,, -Concrete - 80 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,3.6804,2.173676774,79.87,0.2,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Empty - 105 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,4.5996,2.174102096,105,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Empty - 105 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,5.16,2.325581395,105,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Empty - 105 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.24,1.851851852,105,0.15,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Empty - 105 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,3.9996,2.00020002,105,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Empty - 115 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,4.8996,2.040982937,115,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Empty - 115 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,5.52,2.173913043,115,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Empty - 115 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.48,1.724137931,115,0.15,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Empty - 115 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,4.2396,1.886970469,115,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Empty - 125 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,5.1996,1.923224863,125,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Empty - 125 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,5.88,2.040816327,125,0.13,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Empty - 125 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.66,1.639344262,125,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Empty - 125 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,4.4796,1.785873739,125,0.13,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Insulated - 105 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,3.3996,2.941522532,105,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Insulated - 105 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,3.6,3.333333333,105,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Insulated - 105 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,2.64,2.272727273,105,0.15,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Insulated - 105 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,2.9604,2.702337522,105,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Insulated - 115 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,3.6996,2.702994918,115,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Insulated - 115 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,3.96,3.03030303,115,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Insulated - 115 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,2.88,2.083333333,115,0.15,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Insulated - 115 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,3.2796,2.439321869,115,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Insulated - 125 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,4.1004,2.43878646,125,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Insulated - 125 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,4.32,2.777777778,125,0.13,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Insulated - 125 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.12,1.923076923,125,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Insulated - 125 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,3.5196,2.272985567,125,0.13,,,,,,,,,,,,,,,,,,,,, -Concrete - Solid Grout - 105 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,8.4744,1.180024545,105,0.22,,,,,,,,,,,,,,,,,,,,, -Concrete - Solid Grout - 105 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,8.5704,1.40016802,105,0.22,,,,,,,,,,,,,,,,,,,,, -Concrete - Solid Grout - 105 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,8.3328,0.720046083,105,0.21,,,,,,,,,,,,,,,,,,,,, -Concrete - Solid Grout - 105 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,8.3328,0.960061444,105,0.22,,,,,,,,,,,,,,,,,,,,, -Concrete - Solid Grout - 115 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,9.174,1.090037061,115,0.21,,,,,,,,,,,,,,,,,,,,, -Concrete - Solid Grout - 115 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,9.2304,1.300052002,115,0.21,,,,,,,,,,,,,,,,,,,,, -Concrete - Solid Grout - 115 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,10.17,0.589970501,115,0.2,,,,,,,,,,,,,,,,,,,,, -Concrete - Solid Grout - 115 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,9.1224,0.876962203,115,0.2,,,,,,,,,,,,,,,,,,,,, -Concrete - Solid Grout - 125 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,10.1016,0.989942187,125,0.2,,,,,,,,,,,,,,,,,,,,, -Concrete - Solid Grout - 125 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,10.0836,1.190051172,125,0.2,,,,,,,,,,,,,,,,,,,,, -Concrete - Solid Grout - 125 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,10.17,0.589970501,125,0.19,,,,,,,,,,,,,,,,,,,,, -Concrete - Solid Grout - 125 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,10.1268,0.789983015,125,0.2,,,,,,,,,,,,,,,,,,,,, -Concrete Paver,StandardOpaqueMaterial,MediumRough,0.38,4.5024,0.084399431,144,0.2,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 100% Ins. Layer - No Steel in Ins. - Ins. 1 1/2 in.,StandardOpaqueMaterial,MediumRough,13.5,1.8396,7.338551859,133.44,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 100% Ins. Layer - No Steel in Ins. - Ins. 2 in.,StandardOpaqueMaterial,MediumRough,14,1.4496,9.657836645,128.71,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 100% Ins. Layer - No Steel in Ins. - Ins. 3 in.,StandardOpaqueMaterial,MediumRough,15,1.05,14.28571429,120.2,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 100% Ins. Layer - No Steel in Ins. - Ins. 4 in.,StandardOpaqueMaterial,MediumRough,16,0.8496,18.83239171,112.75,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 100% Ins. Layer - No Steel in Ins. - Ins. 6 in.,StandardOpaqueMaterial,MediumRough,18,0.63,28.57142857,100.33,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 100% Ins. Layer - Steel in Ins. - Ins. 1 1/2 in.,StandardOpaqueMaterial,MediumRough,13.5,2.5704,5.25210084,133.44,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 100% Ins. Layer - Steel in Ins. - Ins. 2 in.,StandardOpaqueMaterial,MediumRough,14,2.01,6.965174129,128.71,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 100% Ins. Layer - Steel in Ins. - Ins. 3 in.,StandardOpaqueMaterial,MediumRough,15,1.4796,10.1378751,120.2,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 100% Ins. Layer - Steel in Ins. - Ins. 4 in.,StandardOpaqueMaterial,MediumRough,16,1.1904,13.44086022,112.75,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 100% Ins. Layer - Steel in Ins. - Ins. 6 in.,StandardOpaqueMaterial,MediumRough,18,0.9,20,100.33,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 80% Ins. Layer - No Steel in Ins. - Ins. 1 1/2 in.,StandardOpaqueMaterial,MediumRough,13.5,15.8604,0.851176515,133.44,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 80% Ins. Layer - No Steel in Ins. - Ins. 2 in.,StandardOpaqueMaterial,MediumRough,14,14.7504,0.949126803,128.71,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 80% Ins. Layer - No Steel in Ins. - Ins. 3 in.,StandardOpaqueMaterial,MediumRough,15,11.9904,1.251000801,120.2,0.12,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 80% Ins. Layer - No Steel in Ins. - Ins. 4 in.,StandardOpaqueMaterial,MediumRough,16,10.3404,1.547328923,112.75,0.12,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 80% Ins. Layer - No Steel in Ins. - Ins. 6 in.,StandardOpaqueMaterial,MediumRough,18,8.3604,2.153007033,100.33,0.13,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 80% Ins. Layer - Steel in Ins. - Ins. 1 1/2 in.,StandardOpaqueMaterial,MediumRough,13.5,15.8604,0.851176515,133.44,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 80% Ins. Layer - Steel in Ins. - Ins. 2 in.,StandardOpaqueMaterial,MediumRough,14,25.1796,0.556005655,128.71,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 80% Ins. Layer - Steel in Ins. - Ins. 3 in.,StandardOpaqueMaterial,MediumRough,15,31.5096,0.476045396,120.2,0.12,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 80% Ins. Layer - Steel in Ins. - Ins. 4 in.,StandardOpaqueMaterial,MediumRough,16,38.37,0.416992442,112.75,0.12,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 80% Ins. Layer - Steel in Ins. - Ins. 6 in.,StandardOpaqueMaterial,MediumRough,18,54.0504,0.333022512,100.33,0.13,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 90% Ins. Layer - No Steel in Ins. - Ins. 1 1/2 in.,StandardOpaqueMaterial,MediumRough,13.5,10.7904,1.2511121,133.44,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 90% Ins. Layer - No Steel in Ins. - Ins. 2 in.,StandardOpaqueMaterial,MediumRough,14,9.66,1.449275362,128.71,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 90% Ins. Layer - No Steel in Ins. - Ins. 3 in.,StandardOpaqueMaterial,MediumRough,15,7.32,2.049180328,120.2,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 90% Ins. Layer - No Steel in Ins. - Ins. 4 in.,StandardOpaqueMaterial,MediumRough,16,6.0396,2.649182065,112.75,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 90% Ins. Layer - No Steel in Ins. - Ins. 6 in.,StandardOpaqueMaterial,MediumRough,18,4.7904,3.75751503,100.33,0.12,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 90% Ins. Layer - Steel in Ins. - Ins. 1 1/2 in.,StandardOpaqueMaterial,MediumRough,13.5,11.7396,1.149954002,133.44,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 90% Ins. Layer - Steel in Ins. - Ins. 2 in.,StandardOpaqueMaterial,MediumRough,14,9.66,1.449275362,128.71,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 90% Ins. Layer - Steel in Ins. - Ins. 3 in.,StandardOpaqueMaterial,MediumRough,15,7.6896,1.950686642,120.2,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 90% Ins. Layer - Steel in Ins. - Ins. 4 in.,StandardOpaqueMaterial,MediumRough,16,6.5304,2.450079628,112.75,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 90% Ins. Layer - Steel in Ins. - Ins. 6 in.,StandardOpaqueMaterial,MediumRough,18,5.0604,3.557031065,100.33,0.12,,,,,,,,,,,,,,,,,,,,, -Concrete/Sand Aggregate - 6 in.,StandardOpaqueMaterial,Smooth,6.01,4.29,1.400932401,116,0.2,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Double glass with no low e coatings - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.9,2.522222222,29.09,0.26,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Double glass with no low e coatings - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.26196,12.4828218,20.44,0.26,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Double glass with no low e coatings - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.25296,17.67077799,15.23,0.27,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Double glass with no low e coatings - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,0.25308,22.40398293,12.22,0.27,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Double glass with no low e coatings - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,0.2478,27.72397094,10.26,0.27,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Double glass with no low e coatings - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,0.2484,32.48792271,8.88,0.27,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Double glass with no low e coatings - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.2814,6.503198294,35.69,0.26,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Double glass with no low e coatings - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.27,9.444444444,25.92,0.26,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Single glass pane. stone. or metal pane - No Ins.,StandardOpaqueMaterial,Smooth,2.27,1.1796,1.924381146,29.09,0.26,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Single glass pane. stone. or metal pane - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.27312,11.97275923,20.44,0.26,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Single glass pane. stone. or metal pane - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.2628,17.00913242,15.23,0.27,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Single glass pane. stone. or metal pane - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,0.2592,21.875,12.22,0.27,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Single glass pane. stone. or metal pane - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,0.25512,26.92850423,10.26,0.27,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Single glass pane. stone. or metal pane - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,0.25692,31.41055582,8.88,0.27,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Single glass pane. stone. or metal pane - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.3096,5.910852713,35.69,0.26,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Single glass pane. stone. or metal pane - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.28476,8.954909397,25.92,0.26,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Triple or low e glass - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.78,2.91025641,29.09,0.26,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Triple or low e glass - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.25452,12.84771334,20.44,0.26,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Triple or low e glass - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.24804,18.02128689,15.23,0.27,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Triple or low e glass - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,0.24696,22.95918367,12.22,0.27,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Triple or low e glass - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,0.2478,27.72397094,10.26,0.27,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Triple or low e glass - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,0.2484,32.48792271,8.88,0.27,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Triple or low e glass - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.2652,6.900452489,35.69,0.26,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Triple or low e glass - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.25752,9.902143523,25.92,0.26,,,,,,,,,,,,,,,,,,,,, -CP02 CARPET PAD,MasslessOpaqueMaterial,VeryRough,,,1.229230374,,,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -Douglas Fir-Larch - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,0.9804,1.01999184,34.88,0.39,,,,,,,,,,,,,,,,,,,,, -ECABS-2 BLEACHED 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.814,0.086,0.086,0.847,0.099,0.099,0,0.84,0.1,1,FALSE,, -ECABS-2 COLORED 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.111,0.179,0.179,0.128,0.081,0.081,0,0.84,0.1,1,FALSE,, -ECREF-1 COLORED 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.099,0.219,0.219,0.155,0.073,0.073,0,0.84,0.84,1,FALSE,, -ECREF-2 BLEACHED 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.694,0.168,0.168,0.818,0.11,0.11,0,0.84,0.1,1,FALSE,, -ECREF-2 COLORED 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.099,0.219,0.219,0.155,0.073,0.073,0,0.84,0.1,1,FALSE,, -Expanded perlite - organic bonded - 1 1/2 in. R4.2,StandardOpaqueMaterial,MediumSmooth,1.5,0.36,4.166666667,1,0.3,,,,,,,,,,,,,,,,,,,,, -Expanded perlite - organic bonded - 1 in. R2.8,StandardOpaqueMaterial,MediumSmooth,1,0.36,2.777777778,1,0.3,,,,,,,,,,,,,,,,,,,,, -Expanded perlite - organic bonded - 2 in. R5.6,StandardOpaqueMaterial,MediumSmooth,2,0.36,5.555555556,1,0.3,,,,,,,,,,,,,,,,,,,,, -Expanded perlite - organic bonded - 3 in. R8.3,StandardOpaqueMaterial,MediumSmooth,3,0.36,8.333333333,1,0.3,,,,,,,,,,,,,,,,,,,,, -Expanded perlite - organic bonded - 3/4 in. R2.1,StandardOpaqueMaterial,MediumSmooth,0.75,0.36,2.083333333,1,0.3,,,,,,,,,,,,,,,,,,,,, -Expanded perlite - organic bonded - 4 in. R11,StandardOpaqueMaterial,MediumSmooth,4,0.36,11.11111111,1,0.3,,,,,,,,,,,,,,,,,,,,, -Expanded perlite - organic bonded - 6 in. R17,StandardOpaqueMaterial,MediumSmooth,6,0.36,16.66666667,1,0.3,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 1 1/2 in. R6.3,StandardOpaqueMaterial,MediumSmooth,1.5,0.24,6.25,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 1 1/4 in. R5.2,StandardOpaqueMaterial,MediumSmooth,1.25,0.24,5.208333333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 1 15/16 in. R8.1,StandardOpaqueMaterial,MediumSmooth,1.94,0.24,8.083333333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 1 3/4 in. R7.3,StandardOpaqueMaterial,MediumSmooth,1.75,0.24,7.291666667,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 1 7/8 in. R8.0,StandardOpaqueMaterial,MediumSmooth,1.92,0.24,8,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 1 in. R4.2,StandardOpaqueMaterial,MediumSmooth,1,0.24,4.166666667,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 1/2 in. R2.1,StandardOpaqueMaterial,MediumSmooth,0.5,0.24,2.083333333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 1/4 in. R1.0,StandardOpaqueMaterial,MediumSmooth,0.25,0.24,1.041666667,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 2 2/5 in. R10,StandardOpaqueMaterial,MediumSmooth,2.4,0.24,10,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 2 7/16 in. R10,StandardOpaqueMaterial,MediumSmooth,2.43,0.24,10.125,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 2 in. R8.3,StandardOpaqueMaterial,MediumSmooth,2,0.24,8.333333333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 3 1/2 in. R15,StandardOpaqueMaterial,MediumSmooth,3.5,0.24,14.58333333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 3 1/3 in. R14,StandardOpaqueMaterial,MediumSmooth,3.35,0.24,13.95833333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 3 2/5 in. R14,StandardOpaqueMaterial,MediumSmooth,3.39,0.24,14.125,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 3 in. R13,StandardOpaqueMaterial,MediumSmooth,3.01,0.24,12.54166667,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 3/4 in. R3.1,StandardOpaqueMaterial,MediumSmooth,0.75,0.24,3.125,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 4 1/16 in. R17,StandardOpaqueMaterial,MediumSmooth,4.05,0.24,16.875,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 4 7/10 in. R20,StandardOpaqueMaterial,MediumSmooth,4.71,0.24,19.625,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 5 19/20 in. R25,StandardOpaqueMaterial,MediumSmooth,5.96,0.24,24.83333333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 5 2/5 in. R22,StandardOpaqueMaterial,MediumSmooth,5.2,0.24,21.66666667,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 6 1/10 in. R25,StandardOpaqueMaterial,MediumSmooth,6.11,0.24,25.45833333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 6 7/8 in. R29,StandardOpaqueMaterial,MediumSmooth,6.87,0.24,28.625,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 8 3/5 in. R35,StandardOpaqueMaterial,MediumSmooth,8.38,0.24,34.91666667,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polyurethane - 1 1/4 in. R7.8,StandardOpaqueMaterial,MediumSmooth,1.25,0.1596,7.832080201,1,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polyurethane - 1 in. R6.3,StandardOpaqueMaterial,MediumSmooth,1,0.1596,6.26566416,1,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polyurethane - 1/2 in. R3.1,StandardOpaqueMaterial,MediumSmooth,0.5,0.1596,3.13283208,1,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polyurethane - 2 in. R12.6,StandardOpaqueMaterial,MediumSmooth,2,0.1596,12.53132832,1,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polyurethane - 3/4 in. R4.7,StandardOpaqueMaterial,MediumSmooth,0.75,0.1596,4.69924812,1,0.27,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 1 1/2 in. R7.50,StandardOpaqueMaterial,MediumSmooth,1.5,0.200000004,7.49999985,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 1 1/4 in. R6.25,StandardOpaqueMaterial,MediumSmooth,1.25,0.200000004,6.249999875,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 1 3/4 in. R8.75,StandardOpaqueMaterial,MediumSmooth,1.75,0.200000004,8.749999825,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 1 7/8 in. R9.37,StandardOpaqueMaterial,MediumSmooth,1.88,0.200000004,9.399999812,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 1 in. R5.00,StandardOpaqueMaterial,MediumSmooth,1,0.200000004,4.9999999,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 1/2 in. R2.50,StandardOpaqueMaterial,MediumSmooth,0.5,0.200000004,2.49999995,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 1/4 in. R1.25,StandardOpaqueMaterial,MediumSmooth,0.25,0.200000004,1.249999975,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 2 1/2 in. R12.50,StandardOpaqueMaterial,MediumSmooth,2.5,0.200000004,12.49999975,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 2 in. R10.00,StandardOpaqueMaterial,MediumSmooth,2,0.200000004,9.9999998,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 3 1/2 in. R17.50,StandardOpaqueMaterial,MediumSmooth,3.5,0.200000004,17.49999965,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 3 in. R15.00,StandardOpaqueMaterial,MediumSmooth,3,0.200000004,14.9999997,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 3/4 in. R3.75,StandardOpaqueMaterial,MediumSmooth,0.75,0.200000004,3.749999925,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 4 1/2 in. R22.50,StandardOpaqueMaterial,MediumSmooth,4.5,0.200000004,22.49999955,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 4 in. R20.00,StandardOpaqueMaterial,MediumSmooth,4,0.200000004,19.9999996,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 5 1/2 in. R27.50,StandardOpaqueMaterial,MediumSmooth,5.5,0.200000004,27.49999945,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 5 in. R25.00,StandardOpaqueMaterial,MediumSmooth,5,0.200000004,24.9999995,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 6 1/2 in. R32.50,StandardOpaqueMaterial,MediumSmooth,6.5,0.200000004,32.49999935,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 6 in. R30.00,StandardOpaqueMaterial,MediumSmooth,6,0.200000004,29.9999994,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 8 1/2 in. R42.50,StandardOpaqueMaterial,MediumSmooth,8.5,0.200000004,42.49999915,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 8 in. R40.00,StandardOpaqueMaterial,MediumSmooth,8,0.200000004,39.9999992,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -F04 Wall air space resistance,AirGap,,,46.22314532,0.021634183,,,,,,,,,,,,,,,,,,,,,,, -F05 Ceiling air space resistance,AirGap,,,38.51928777,0.02596102,,,,,,,,,,,,,,,,,,,,,,, -F08 Metal surface,StandardOpaqueMaterial,Smooth,0.031496063,313.947603,0.000100323,488.4363635,0.119422948,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -F16 Acoustic tile,StandardOpaqueMaterial,MediumSmooth,0.751968504,0.416008308,1.807580497,22.97348949,0.140919079,0.9,0.3,0.3,,,,,,,,,,,,,,,,,, -Fiber cement board - 63 lb/ft3 - 1/3 in.,StandardOpaqueMaterial,Smooth,0.31,1.2996,0.238534934,63,0.2,,,,,,,,,,,,,,,,,,,,, -Fiber cement board - 88 lb/ft3 - 1/2 in.,StandardOpaqueMaterial,Smooth,0.47,1.7004,0.276405552,88,0.2,,,,,,,,,,,,,,,,,,,,, -Fiber cement board - 88 lb/ft3 - 1/3 in.,StandardOpaqueMaterial,Smooth,0.31,1.7004,0.182310045,88,0.2,,,,,,,,,,,,,,,,,,,,, -Fiberboard sheathing - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.4896,1.02124183,24.96,0.31,,,,,,,,,,,,,,,,,,,,, -Fixed Window 2.00/0.40/0.31,SimpleGlazing,,,,,,,,,,,0.35,0.4,0.31,,,,,,,,,,,,,, -Fixed Window 2.00/0.45/0.35,SimpleGlazing,,,,,,,,,,,0.35,0.45,0.35,,,,,,,,,,,,,, -Fixed Window 2.30/0.40/0.31,SimpleGlazing,,,,,,,,,,,0.4,0.4,0.31,,,,,,,,,,,,,, -Fixed Window 2.56/0.45/0.35,SimpleGlazing,,,,,,,,,,,0.45,0.45,0.35,,,,,,,,,,,,,, -Fixed Window 2.62/0.30/0.21,SimpleGlazing,,,,,,,,,,,0.459978667,0.3,0.21,,,,,,,,,,,,,, -Fixed Window 2.67/0.30/0.21,SimpleGlazing,,,,,,,,,,,0.469978203,0.49,0.38,,,,,,,,,,,,,, -Fixed Window 2.96/0.39/0.31,SimpleGlazing,,,,,,,,,,,0.519975884,0.39,0.31,,,,,,,,,,,,,, -Fixed Window 2.96/0.49/0.41,SimpleGlazing,,,,,,,,,,,0.519975884,0.49,0.41,,,,,,,,,,,,,, -Fixed Window 2.96/0.62/0.54,SimpleGlazing,,,,,,,,,,,0.519975884,0.62,0.54,,,,,,,,,,,,,, -Fixed Window 3.12/0.40/0.31,SimpleGlazing,,,,,,,,,,,0.55,0.4,0.31,,,,,,,,,,,,,, -Fixed Window 3.24/0.25/0.16,SimpleGlazing,,,,,,,,,,,0.569973565,0.25,0.16,,,,,,,,,,,,,, -Fixed Window 3.24/0.39/0.31,SimpleGlazing,,,,,,,,,,,0.569973565,0.39,0.31,,,,,,,,,,,,,, -Fixed Window 3.24/0.49/0.41,SimpleGlazing,,,,,,,,,,,0.569973565,0.49,0.41,,,,,,,,,,,,,, -Fixed Window 3.35/0.36/0.27,SimpleGlazing,,,,,,,,,,,0.589972638,0.36,0.27,,,,,,,,,,,,,, -Fixed Window 3.35/0.39/0.31,SimpleGlazing,,,,,,,,,,,0.589972638,0.39,0.31,,,,,,,,,,,,,, -Fixed Window 3.53/0.41/0.32,SimpleGlazing,,,,,,,,,,,0.619971246,0.41,0.32,,,,,,,,,,,,,, -Fixed Window 3.69/0.25/0.16,SimpleGlazing,,,,,,,,,,,0.65,0.25,0.16,,,,,,,,,,,,,, -Fixed Window 3.69/0.70/0.60,SimpleGlazing,,,,,,,,,,,0.65,0.7,0.6,,,,,,,,,,,,,, -Fixed Window 3.81/0.39/0.27,SimpleGlazing,,,,,,,,,,,0.519975884,0.39,0.27,,,,,,,,,,,,,, -Fixed Window 3.81/0.49/0.38,SimpleGlazing,,,,,,,,,,,0.519975884,0.49,0.38,,,,,,,,,,,,,, -Fixed Window 4.09/0.26/0.13,SimpleGlazing,,,,,,,,,,,0.719966609,0.25,0.13,,,,,,,,,,,,,, -Fixed Window 4.09/0.36/0.23,SimpleGlazing,,,,,,,,,,,0.719966609,0.36,0.23,,,,,,,,,,,,,, -Fixed Window 4.09/0.39/0.25,SimpleGlazing,,,,,,,,,,,0.719966609,0.39,0.25,,,,,,,,,,,,,, -Fixed Window 4.26/0.25/0.16,SimpleGlazing,,,,,,,,,,,0.75,0.25,0.16,,,,,,,,,,,,,, -Fixed Window 5.84/0.25/0.11,SimpleGlazing,,,,,,,,,,,1.028483473,0.25,0.11,,,,,,,,,,,,,, -Fixed Window 5.84/0.39/0.22,SimpleGlazing,,,,,,,,,,,1.028483473,0.39,0.22,,,,,,,,,,,,,, -Fixed Window 5.84/0.44/0.27,SimpleGlazing,,,,,,,,,,,1.028483473,0.44,0.27,,,,,,,,,,,,,, -Fixed Window 5.84/0.54/0.38,SimpleGlazing,,,,,,,,,,,1.028483473,0.54,0.38,,,,,,,,,,,,,, -Fixed Window 5.84/0.61/0.47,SimpleGlazing,,,,,,,,,,,1.028483473,0.61,0.47,,,,,,,,,,,,,, -Fixed Window 5.84/0.70/0.60,SimpleGlazing,,,,,,,,,,,1.028483473,0.7,0.6,,,,,,,,,,,,,, -G01 13mm gypsum board,StandardOpaqueMaterial,Smooth,0.5,1.10957004,0.450625001,49.9424,0.260516252,0.9,0.7,0.5,,,,,,,,,,,,,,,,,, -G01a 19mm gypsum board,StandardOpaqueMaterial,MediumSmooth,0.748031496,1.109355488,0.674293772,49.94236846,0.260342027,0.9,0.4,0.4,,,,,,,,,,,,,,,,,, -G05 25mm wood,StandardOpaqueMaterial,MediumSmooth,1,1.04002077,0.961519259,37.95620003,0.389318812,0.9,0.5,0.5,,,,,,,,,,,,,,,,,, -Gap_1_W_0_0018,Gas,,0.070866142,,,,,,,,Air,,,,,,,,,,,,,,,,, -Gap_1_W_0_0024,Gas,,0.094488189,,,,,,,,Air,,,,,,,,,,,,,,,,, -Gap_1_W_0_0025,Gas,,0.098425197,,,,,,,,Air,,,,,,,,,,,,,,,,, -Gap_1_W_0_0032,Gas,,0.125984252,,,,,,,,Air,,,,,,,,,,,,,,,,, -Gap_1_W_0_0038,Gas,,0.149606299,,,,,,,,Air,,,,,,,,,,,,,,,,, -Gap_1_W_0_0042,Gas,,0.165354331,,,,,,,,Air,,,,,,,,,,,,,,,,, -Gap_1_W_0_0043,Gas,,0.169291339,,,,,,,,Air,,,,,,,,,,,,,,,,, -Glass fiber batt - 10 in. R30 (CEC Default),StandardOpaqueMaterial,MediumRough,10,0.3336,29.97601918,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass fiber batt - 12 in. R38 (CEC Default),StandardOpaqueMaterial,MediumRough,12,0.3156,38.02281369,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass fiber batt - 3 1/2 in. R11 (CEC Default),StandardOpaqueMaterial,MediumRough,3.5,0.318,11.00628931,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass fiber batt - 3 1/2 in. R13 (CEC Default),StandardOpaqueMaterial,MediumRough,3.5,0.2688,13.02083333,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass fiber batt - 3 1/2 in. R15 (CEC Default),StandardOpaqueMaterial,MediumRough,3.5,0.2328,15.03436426,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass fiber batt - 4 1/2 in.,StandardOpaqueMaterial,MediumRough,4.5,0.3,15,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass fiber batt - 4 in.,StandardOpaqueMaterial,MediumRough,4,0.3,13.33333333,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass fiber batt - 5 1/2 in. R19 (CEC Default),StandardOpaqueMaterial,MediumRough,5.5,0.306,17.97385621,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass fiber batt - 5 1/2 in. R21 (CEC Default),StandardOpaqueMaterial,MediumRough,5.5,0.2616,21.02446483,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass fiber batt - 5 in.,StandardOpaqueMaterial,MediumRough,5,0.3,16.66666667,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass fiber batt - 6 1/2 in.,StandardOpaqueMaterial,MediumRough,6.5,0.3,21.66666667,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass fiber batt - 6 in.,StandardOpaqueMaterial,MediumRough,6,0.3,20,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass fiber batt - 7 1/4 in. R25 (CEC Default),StandardOpaqueMaterial,MediumRough,7.25,0.3024,23.97486772,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass fiber batt - 7 1/4 in. R30 (CEC Default),StandardOpaqueMaterial,MediumRough,7.25,0.2904,24.96556474,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass fiber batt - 8 1/4 in. R30C (CEC Default),StandardOpaqueMaterial,MediumRough,8.25,0.2748,30.02183406,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass_2010F_LayerAvg,StandardGlazing,,0.087007874,6.933471799,0.144227889,,,,,,,,,,SpectralAverage,0.434294,0.4183747,0.3410654,0.797579,0.043577,0.056031,0,0.042274,0.84,1,FALSE,, -Glass_2022F_LayerAvg,StandardGlazing,,0.153543307,6.933471799,0.144227889,,,,,,,,,,SpectralAverage,0.355897,0.3940945,0.2656452,0.677694,0.042734,0.05547,0,0.046,0.84,1,FALSE,, -Glass_2027F_LayerAvg,StandardGlazing,,0.157480315,6.933471799,,,,,,,,,,,SpectralAverage,0.369744,0.4700695,0.340935,0.765222,0.0546,0.073741,0,0.03675,0.84,1,FALSE,, -Glass_2052_LayerAvg,StandardGlazing,,0.329527559,6.933471799,,,,,,,,,,,SpectralAverage,0.507767,0.05422805,0.05449309,0.586833,0.05805,0.058397,0,0.84,0.84,1,FALSE,, -Glass_2175_LayerAvg,StandardGlazing,,0.338582677,6.933471799,0.144227889,,,,,,,,,,SpectralAverage,0.167758,0.2176064,0.4379779,0.416044,0.078729,0.10654,0,0.84,0.84,1,FALSE,, -GREEN 3MM,StandardGlazing,,0.118110236,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.635,0.063,0.063,0.822,0.075,0.075,0,0.84,0.84,1,FALSE,, -GREEN 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.487,0.056,0.056,0.749,0.07,0.07,0,0.84,0.84,1,FALSE,, -GREY 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.455,0.053,0.053,0.431,0.052,0.052,0,0.84,0.84,1,FALSE,, -Ground_Floor_R11_T2013,StandardOpaqueMaterial,Smooth,1.74123,0.15963,10.91,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -Ground_Floor_R17_T2013,StandardOpaqueMaterial,Smooth,2.71324,0.15963,17.66,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -Ground_Floor_R22_T2013,StandardOpaqueMaterial,Smooth,3.51125,0.15963,22.47,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -Gypsum Board - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,1.10004,0.454528926,40,0.27,,,,,,,,,,,,,,,,,,,,, -Gypsum Board - 1/2 in. CBES,StandardOpaqueMaterial,Smooth,0.5,1.1101,,40,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -Gypsum Board - 3/4 in.,StandardOpaqueMaterial,MediumSmooth,0.75,1.10004,0.681793389,40,0.27,,,,,,,,,,,,,,,,,,,,, -Gypsum Board - 3/8 in.,StandardOpaqueMaterial,MediumSmooth,0.38,1.10004,0.345441984,40,0.27,,,,,,,,,,,,,,,,,,,,, -Gypsum Board - 5/8 in.,StandardOpaqueMaterial,MediumSmooth,0.63,1.10004,0.572706447,40,0.27,,,,,,,,,,,,,,,,,,,,, -Gypsum Or Plaster Board - 3/8 in.,StandardOpaqueMaterial,MediumSmooth,0.374015748,4.021413643,0.093006037,49.94236846,0.260342027,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Gypsum partition block - 3 cells - 4 in. x 12 in. x 30 in. - 4 in.,StandardOpaqueMaterial,MediumRough,4,2.4,1.666666667,53.1,0.19,,,,,,,,,,,,,,,,,,,,, -Gypsum partition block - 4 cells - 3 in. x 12 in. x 30 in. - 3 in.,StandardOpaqueMaterial,MediumRough,3,2.22,1.351351351,53.1,0.19,,,,,,,,,,,,,,,,,,,,, -Gypsum partition block - solid - 3 in. x 12 in. x 30 in. - 3 in.,StandardOpaqueMaterial,MediumRough,3,2.3796,1.260716087,62.4,0.19,,,,,,,,,,,,,,,,,,,,, -Gypsum plaster - 80 lb/ft3 - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,3.2004,0.156230471,80,0.26,,,,,,,,,,,,,,,,,,,,, -Gypsum plaster - 80 lb/ft3 - 5/8 in.,StandardOpaqueMaterial,Smooth,0.63,3.2004,0.196850394,80,0.26,,,,,,,,,,,,,,,,,,,,, -Gypsum plaster - on metal lath 70 lb/ft3 - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,2.6004,0.288417167,70,0.26,,,,,,,,,,,,,,,,,,,,, -Gypsum plaster - on metal lath 80 lb/ft3 - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,3.2004,0.234345707,80,0.26,,,,,,,,,,,,,,,,,,,,, -Hard Board - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,0.72,1.041666667,50,0.31,,,,,,,,,,,,,,,,,,,,, -Hardboard - HDF - 50 lb/ft3 - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.7296,0.685307018,50,0.31,,,,,,,,,,,,,,,,,,,,, -Hardboard - HDF - 50 lb/ft3 - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,0.7296,1.027960526,50,0.31,,,,,,,,,,,,,,,,,,,,, -Hardboard - HDF - 50 lb/ft3 - 3/8 in.,StandardOpaqueMaterial,Smooth,0.38,0.7296,0.520833333,50,0.31,,,,,,,,,,,,,,,,,,,,, -Hardboard - HDF - 50 lb/ft3 - 5/8 in.,StandardOpaqueMaterial,Smooth,6.30E-01,0.7296,8.63E-01,50,0.31,,,,,,,,,,,,,,,,,,,,, -Hardwood - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,1.1604,0.861771803,42.43,0.39,,,,,,,,,,,,,,,,,,,,, -Hardwood - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,1.1604,0.430885901,42.43,0.39,,,,,,,,,,,,,,,,,,,,, -Hardwood - 3/4 in.,StandardOpaqueMaterial,MediumSmooth,0.75,1.1604,0.646328852,42.43,0.39,,,,,,,,,,,,,,,,,,,,, -HB Part. Brd - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,1.17996,0.635614767,50,0.31,,,,,,,,,,,,,,,,,,,,, -HW CONCRETE,StandardOpaqueMaterial,Rough,4,9.09153953,0.439969489,139.83872,0.2,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -HW CONCRETE 8 in,StandardOpaqueMaterial,Rough,8,9.09153953,0.879938978,139.83872,0.2,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -I01 25mm insulation board,StandardOpaqueMaterial,MediumRough,1,0.208004154,4.807596295,2.684402305,0.289003535,0.9,0.6,0.6,,,,,,,,,,,,,,,,,, -I02 50mm insulation board,StandardOpaqueMaterial,MediumRough,2,0.208004154,9.615192591,2.684402305,0.289003535,0.9,0.6,0.6,,,,,,,,,,,,,,,,,, -IEAD NonRes Roof Insulation-1.76,StandardOpaqueMaterial,MediumRough,2.912618228,0.339740118,8.573077103,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -IEAD Roof Insulation R-3.47 IP,StandardOpaqueMaterial,MediumRough,1.178836998,0.339740118,3.469819827,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 1 1/2 in. Polyurethane Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,9,0.4704,19.13265306,100.33,0.23,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 1 1/2 in. Polyurethane Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,11,0.57,19.29824561,109.36,0.22,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 2 1/2 in. EPS Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,11,0.51648,21.29801735,76.81,0.23,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 2 1/2 in. EPS Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,13,0.60612,21.44789811,86.54,0.22,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 2 in. EPS Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,10,0.6096,16.40419948,90.4,0.23,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 2 in. EPS Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,12,0.72,16.66666667,100.33,0.22,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 2 in. Polyurethane Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,10,0.4404,22.70663034,90.4,0.23,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 2 in. Polyurethane Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,12,0.5196,23.09468822,100.33,0.22,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 2 in. XPS Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,10,0.4704,21.2585034,90.4,0.23,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 2 in. XPS Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,12,0.57,21.05263158,100.33,0.22,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 3 in. EPS Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,12,0.5004,23.98081535,75.5,0.23,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 3 in. EPS Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,14,0.57,24.56140351,86.14,0.22,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 3 in. XPS Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,12,0.39,30.76923077,75.5,0.23,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 3 in. XPS Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,14,0.45,31.11111111,86.14,0.22,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 4 1/2 in. Polyurethane Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,15,0.3504,42.80821918,60.6,0.23,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 4 1/2 in. Polyurethane Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,17,0.3996,42.54254254,71.12,0.22,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 4 in. EPS Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,14,0.4296,32.58845438,64.86,0.23,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 4 in. EPS Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,16,0.5004,31.97442046,75.5,0.22,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 4 in. XPS Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,14,0.3504,39.9543379,64.86,0.23,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 4 in. XPS Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,16,0.39,41.02564103,75.5,0.22,,,,,,,,,,,,,,,,,,,,, -Insulation 1m,StandardOpaqueMaterial,Smooth,39.37,0.13876,,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -Interior Wall Addi Insul,StandardOpaqueMaterial,MediumRough,1.00E-06,0.299941999,3.33E-06,1.399999086,0.199866248,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Light Roof - 2/5 in.,StandardOpaqueMaterial,VeryRough,0.2,2.4012,0.083291687,120,0.2,,,,,,,,,,,,,,,,,,,,, -Linoleum/cork tile - 1/4 in.,StandardOpaqueMaterial,MediumRough,0.25,0.51,0.490196078,29,0.45,,,,,,,,,,,,,,,,,,,,, -LoE CLEAR 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.6,0.17,0.22,0.84,0.055,0.078,0,0.84,0.1,1,FALSE,, -LoE SPEC SEL CLEAR 3MM,StandardGlazing,,0.118110236,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.45,0.34,0.37,0.78,0.07,0.06,0,0.84,0.03,1,FALSE,, -LoE SPEC SEL CLEAR 6MM Rev,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.43,0.42,0.3,0.77,0.06,0.07,0,0.03,0.84,1,FALSE,, -LoE SPEC SEL TINT 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.26,0.14,0.41,0.46,0.06,0.04,0,0.84,0.03,1,FALSE,, -LoE TINT 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.36,0.093,0.2,0.5,0.035,0.054,0,0.84,0.1,1,FALSE,, -Loose fill - Mineral fiber - 2 lb/ft3 - 13 3/4 in.,StandardOpaqueMaterial,Rough,13.75,0.336,40.92261905,2,0.2,,,,,,,,,,,,,,,,,,,,, -Loose fill - Mineral fiber - 2 lb/ft3 - 4 in.,StandardOpaqueMaterial,Rough,4,0.336,11.9047619,2,0.2,,,,,,,,,,,,,,,,,,,,, -Loose fill - Mineral fiber - 2 lb/ft3 - 6 1/2 in.,StandardOpaqueMaterial,Rough,6.5,0.336,19.3452381,2,0.2,,,,,,,,,,,,,,,,,,,,, -Loose fill - Mineral fiber - 2 lb/ft3 - 7 1/2 in.,StandardOpaqueMaterial,Rough,7.5,0.336,22.32142857,2,0.2,,,,,,,,,,,,,,,,,,,,, -Loose fill - Mineral fiber - 2 lb/ft3 - 8 1/4 in.,StandardOpaqueMaterial,Rough,8.25,0.336,24.55357143,2,0.2,,,,,,,,,,,,,,,,,,,,, -Loose fill - Mineral fiber - closed sidewalls - 3 1/2 in.,StandardOpaqueMaterial,Rough,3.5,0.336,10.41666667,2,0.2,,,,,,,,,,,,,,,,,,,,, -M01 100mm brick,StandardOpaqueMaterial,MediumRough,4,6.170789901,0.648215231,119.8616843,0.188688258,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -M11 100mm lightweight concrete,StandardOpaqueMaterial,MediumRough,4,3.674740053,1.088512369,79.90778954,0.200630553,0.9,0.5,0.5,,,,,,,,,,,,,,,,,, -M15 200mm heavyweight concrete,StandardOpaqueMaterial,MediumRough,8,13.52027001,0.591704159,139.8386317,0.214961307,0.9,0.5,0.5,,,,,,,,,,,,,,,,,, -Maple - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,1.14,0.877192982,41.87,0.39,,,,,,,,,,,,,,,,,,,,, -Mass NonRes Wall Insulation-0.43,StandardOpaqueMaterial,MediumRough,0.017196119,0.339740118,0.050615509,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Mass Wall Insulation R-4.23 IP,StandardOpaqueMaterial,MediumRough,1.438471204,0.339740118,4.234033978,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Mastic asphalt (heavy - 20% grit) - 1 in.,StandardOpaqueMaterial,VeryRough,1,1.2996,0.769467528,59,0.22,,,,,,,,,,,,,,,,,,,,, -MAT-CC05 4 HW CONCRETE,StandardOpaqueMaterial,Rough,4,9.089781528,0.440054581,139.8386317,0.199866246,0.9,0.85,0.85,,,,,,,,,,,,,,,,,, -MAT-CC05 8 HW CONCRETE,StandardOpaqueMaterial,Rough,8,9.089781528,0.880109162,139.8386317,0.199866246,0.9,0.85,0.85,,,,,,,,,,,,,,,,,, -MAT-SHEATH,MasslessOpaqueMaterial,,,6.240124619,0.16025321,0.043699572,0.000167192,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Metal Building Semi-Cond Wall Insulation-0.54,StandardOpaqueMaterial,MediumRough,0.604172732,0.339740118,1.778337913,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Metal Building Wall Insulation R-4.14 IP,StandardOpaqueMaterial,MediumRough,1.404445223,0.339740118,4.133881011,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Metal Deck - 1/16 in.,StandardOpaqueMaterial,Smooth,0.0625,314.4,0.000198791,488.22,0.12,,,,,,,,,,,,,,,,,,,,, -Metal Decking,StandardOpaqueMaterial,MediumSmooth,0.059055118,312.0478318,0.00018925,479.4467372,0.099933123,0.9,0.6,0.6,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 16inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,9.383,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 16inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,10.756,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 16inOC - 2x6 - R0 ins.,MasslessOpaqueMaterial,,,,0.003,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 16inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,5.309,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 16inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,5.854,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 16inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,6.92,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 16inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,7.414,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 16inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,7.815,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 24inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,12.443,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 24inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,14.569,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 24inOC - 2x6 - R0 ins.,MasslessOpaqueMaterial,,,,0.003,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 24inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,6.576,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 24inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,7.544,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 24inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,9.037,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 24inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,9.564,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 24inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,10.336,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,10.16,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,10.92,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x12 - R30 ins.,MasslessOpaqueMaterial,,,,11.42,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,12.34,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x14 - R38 ins.,MasslessOpaqueMaterial,,,,12.97,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,6.01,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,6.52,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,6.96,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x4 - R19 ins.,MasslessOpaqueMaterial,,,,6.52,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,6.39,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,6.96,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x6 - R15 ins.,MasslessOpaqueMaterial,,,,8.16,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,8.26,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,8.68,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x8 - R21 ins.,MasslessOpaqueMaterial,,,,9.01,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,12.97,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,14.13,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x12 - R30 ins.,MasslessOpaqueMaterial,,,,14.65,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,16.44,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x14 - R38 ins.,MasslessOpaqueMaterial,,,,17.13,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,7.27,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,8.06,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,8.68,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x4 - R19 ins.,MasslessOpaqueMaterial,,,,8.06,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,7.61,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,8.36,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x6 - R15 ins.,MasslessOpaqueMaterial,,,,9.89,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,10.31,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,10.76,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x8 - R21 ins.,MasslessOpaqueMaterial,,,,11.42,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 16inOC - 2x4 - R0 ins.,MasslessOpaqueMaterial,,,,0.643,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 16inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,2.924,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 16inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,3.068,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 16inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,3.199,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 16inOC - 2x4 - R5 ins.,MasslessOpaqueMaterial,,,,1.309,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 16inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,3.924,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 16inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,4.078,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 16inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,4.558,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 16inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,4.71,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 16inOC - 2x8 - R25 ins.,MasslessOpaqueMaterial,,,,4.789,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 16inOC - 2x8 - R30 ins.,MasslessOpaqueMaterial,,,,4.829,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 24inOC - 2x4 - R0 ins.,MasslessOpaqueMaterial,,,,0.658,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 24inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,3.222,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 24inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,3.386,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 24inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,3.536,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 24inOC - 2x4 - R5 ins.,MasslessOpaqueMaterial,,,,1.463,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 24inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,4.558,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 24inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,4.671,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 24inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,4.996,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 24inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,5.171,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 24inOC - 2x8 - R25 ins.,MasslessOpaqueMaterial,,,,5.263,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 24inOC - 2x8 - R30 ins.,MasslessOpaqueMaterial,,,,5.309,,,,,,,,,,,,,,,,,,,,,,, -Metal Insulated Panels - 2 1/2 in.,StandardOpaqueMaterial,Smooth,2.5,0.16644,15.02042778,28.47,0.26,,,,,,,,,,,,,,,,,,,,, -Metal Insulated Panels - 2 in.,StandardOpaqueMaterial,Smooth,2,0.16704,11.97318008,34.87,0.26,,,,,,,,,,,,,,,,,,,,, -Metal Insulated Panels - 3 in.,StandardOpaqueMaterial,Smooth,3,0.16656,18.01152738,24.11,0.26,,,,,,,,,,,,,,,,,,,,, -Metal Insulated Panels - 4 in.,StandardOpaqueMaterial,Smooth,4,0.16992,23.54048964,18.54,0.26,,,,,,,,,,,,,,,,,,,,, -Metal Insulated Panels - 5 in.,StandardOpaqueMaterial,Smooth,5,0.1698,29.44640754,15.14,0.27,,,,,,,,,,,,,,,,,,,,, -Metal Insulated Panels - 6 in.,StandardOpaqueMaterial,Smooth,6,0.16584,36.17945007,12.84,0.27,,,,,,,,,,,,,,,,,,,,, -Metal Roof Insulation R-5.21 IP,StandardOpaqueMaterial,MediumRough,1.769246081,0.339740118,5.207645452,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Metal Roof Surface,StandardOpaqueMaterial,Smooth,0.031496063,313.947603,0.000100323,488.4363635,0.119422948,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Metal Roof Surface - Cool Roof,StandardOpaqueMaterial,Smooth,0.031496063,313.947603,0.000100323,488.4363635,0.119422948,0.75,0.37,0.7,,,,,,,,,,,,,,,,,, -Metal Roof Surface - Highly Reflective,StandardOpaqueMaterial,Smooth,0.031496063,313.947603,0.000100323,488.4363635,0.119422948,0.75,0.45,0.7,,,,,,,,,,,,,,,,,, -Metal Roofing,StandardOpaqueMaterial,MediumSmooth,0.059055118,312.0478318,0.00018925,479.4467372,0.099933123,0.9,0.6,0.6,,,,,,,,,,,,,,,,,, -Metal Roofing - Cool Roof,StandardOpaqueMaterial,MediumSmooth,0.059055118,312.0478318,0.00018925,479.4467372,0.099933123,0.75,0.37,0.6,,,,,,,,,,,,,,,,,, -Metal Roofing - Highly Reflective,StandardOpaqueMaterial,MediumSmooth,0.059055118,312.0478318,0.00018925,479.4467372,0.099933123,0.75,0.45,0.6,,,,,,,,,,,,,,,,,, -Metal Screw Down Roof - No Thrml Blk - R10 ins.,MasslessOpaqueMaterial,,,,5.756,,,,,,,,,,,,,,,,,,,,,,, -Metal Screw Down Roof - No Thrml Blk - R11 ins.,MasslessOpaqueMaterial,,,,6.414,,,,,,,,,,,,,,,,,,,,,,, -Metal Screw Down Roof - No Thrml Blk - R13ins.,MasslessOpaqueMaterial,,,,6.912,,,,,,,,,,,,,,,,,,,,,,, -Metal Screw Down Roof - No Thrml Blk - R16 ins.,MasslessOpaqueMaterial,,,,8.654,,,,,,,,,,,,,,,,,,,,,,, -Metal Screw Down Roof - No Thrml Blk - R19 ins.,MasslessOpaqueMaterial,,,,9.424,,,,,,,,,,,,,,,,,,,,,,, -Metal Semi-Cond Roof Insulation-1.05,StandardOpaqueMaterial,MediumRough,1.664068118,0.339740118,4.898061868,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Metal Siding,StandardOpaqueMaterial,Smooth,0.059055118,311.7288921,0.000189444,479.999849,0.097926818,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Metal Siding - 1/16 in.,StandardOpaqueMaterial,Smooth,0.0625,314.4,0.000198791,488.22,0.12,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam - 1/16 in.,StandardOpaqueMaterial,Smooth,0.0625,3.9996,0.015626563,488.22,0.12,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam - 1/16 in. CBES,StandardOpaqueMaterial,MediumRough,0.06,4.0241,,488.22,0.12,0.85,0.37,0.85,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R10 + R10 Ins.,MasslessOpaqueMaterial,,,,15.093,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R10 + R11 Ins.,MasslessOpaqueMaterial,,,,15.613,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R10 + R13 Ins.,MasslessOpaqueMaterial,,,,16.461,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R10 + R19 Ins.,MasslessOpaqueMaterial,,,,18.451,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R11 + R11 Ins.,MasslessOpaqueMaterial,,,,15.887,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R11 + R13 Ins.,MasslessOpaqueMaterial,,,,16.764,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R11 + R19 Ins.,MasslessOpaqueMaterial,,,,18.828,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R13 + R13 Ins.,MasslessOpaqueMaterial,,,,17.402,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R13 + R19 Ins.,MasslessOpaqueMaterial,,,,19.628,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R16 + R19 Ins.,MasslessOpaqueMaterial,,,,20.497,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R19 + R19 Ins.,MasslessOpaqueMaterial,,,,20.959,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - Ins. and Filled Cavity - R19 + R10 Ins.,MasslessOpaqueMaterial,,,,23.61,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - R10 ins.,MasslessOpaqueMaterial,,,,9.529,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - R11 ins.,MasslessOpaqueMaterial,,,,10.09,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - R13 ins.,MasslessOpaqueMaterial,,,,11.268,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - R16 ins.,MasslessOpaqueMaterial,,,,13.109,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - R19 ins.,MasslessOpaqueMaterial,,,,14.605,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - R6 ins.,MasslessOpaqueMaterial,,,,5.208,,,,,,,,,,,,,,,,,,,,,,, -Metal Surface,StandardOpaqueMaterial,Smooth,0.031496063,313.947603,0.000100323,488.4363635,0.119422948,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Mortar - Cement - 1 3/4 in.,StandardOpaqueMaterial,Smooth,1.76,5.01,0.351297405,116,0.2,,,,,,,,,,,,,,,,,,,,, -Mortar - Cement - 1 in.,StandardOpaqueMaterial,Smooth,1.01,5.0304,0.200779262,116,0.2,,,,,,,,,,,,,,,,,,,,, -NACM_Carpet 3/4in,StandardOpaqueMaterial,Smooth,0.75,0.34691,,18,0.33,0.9,0.7,0.9,,,,,,,,,,,,,,,,,, -NACM_Concrete 4in_140lb/ft3,StandardOpaqueMaterial,MediumRough,4,13.52932,,139.78,0.22,0.75,0.92,0.75,,,,,,,,,,,,,,,,,, -NACM_Gypsum Board 5/8in,StandardOpaqueMaterial,MediumRough,0.63,1.1101,,40,0.27,0.9,0.7,0.5,,,,,,,,,,,,,,,,,, -Nonres_Floor_Insulation,MasslessOpaqueMaterial,MediumSmooth,,,16.3699766,,,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Oak - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,1.1796,0.847744998,43.93,0.39,,,,,,,,,,,,,,,,,,,,, -OSB - Oriented Strand Board - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,0.6204,0.805931657,41,0.45,,,,,,,,,,,,,,,,,,,,, -OSB - Oriented Strand Board - 3/4 in.,StandardOpaqueMaterial,MediumSmooth,0.75,0.9096,0.824538259,41,0.45,,,,,,,,,,,,,,,,,,,,, -OSB - Oriented Strand Board - 5/8 in.,StandardOpaqueMaterial,MediumSmooth,0.63,0.7596,0.829383886,41,0.45,,,,,,,,,,,,,,,,,,,,, -Perlite board - 1 1/2 in. R3.8,StandardOpaqueMaterial,Rough,1.5,0.3996,3.753753754,10,0.2,,,,,,,,,,,,,,,,,,,,, -Perlite board - 1 in. R2.5,StandardOpaqueMaterial,Rough,1,0.3996,2.502502503,10,0.2,,,,,,,,,,,,,,,,,,,,, -Perlite board - 2 in. R5.0,StandardOpaqueMaterial,Rough,2,0.3996,5.005005005,10,0.2,,,,,,,,,,,,,,,,,,,,, -Perlite board - 3/4 in. R1.9,StandardOpaqueMaterial,Rough,0.75,0.3996,1.876876877,10,0.2,,,,,,,,,,,,,,,,,,,,, -Perlite plaster - 25 lb/ft3 - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.6,0.833333333,25,0.32,,,,,,,,,,,,,,,,,,,,, -Perlite plaster - 38 lb/ft3 - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,1.2996,0.384733764,38,0.32,,,,,,,,,,,,,,,,,,,,, -Pine (oven-dried) - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,0.6396,1.563477173,23,0.45,,,,,,,,,,,,,,,,,,,,, -Plaster/Sand Aggregate - 1 in.,StandardOpaqueMaterial,Smooth,1.01,5.0304,0.200779262,116,0.2,,,,,,,,,,,,,,,,,,,,, -Plywood - 1 1/2 in.,StandardOpaqueMaterial,MediumSmooth,1.5,0.8004,1.874062969,30,0.45,,,,,,,,,,,,,,,,,,,,, -Plywood - 1 1/4 in.,StandardOpaqueMaterial,MediumSmooth,1.25,0.8004,1.56171914,30,0.45,,,,,,,,,,,,,,,,,,,,, -Plywood - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,0.8004,1.249375312,30,0.45,,,,,,,,,,,,,,,,,,,,, -Plywood - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,0.8004,0.624687656,30,0.45,,,,,,,,,,,,,,,,,,,,, -Plywood - 1/4 in.,StandardOpaqueMaterial,MediumSmooth,0.25,0.8004,0.312343828,30,0.45,,,,,,,,,,,,,,,,,,,,, -Plywood - 3/4 in.,StandardOpaqueMaterial,MediumSmooth,0.75,0.8004,0.937031484,30,0.45,,,,,,,,,,,,,,,,,,,,, -Plywood - 3/8 in.,StandardOpaqueMaterial,MediumSmooth,0.38,0.8004,0.474762619,30,0.45,,,,,,,,,,,,,,,,,,,,, -Plywood - 5/8 in.,StandardOpaqueMaterial,MediumSmooth,0.63,0.8004,0.787106447,30,0.45,,,,,,,,,,,,,,,,,,,,, -Plywood - 5/8 in. CBES,StandardOpaqueMaterial,Smooth,0.63,0.83257,,30,0.45,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Pulpboard or paper plaster - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.5004,0.999200639,38,0.32,,,,,,,,,,,,,,,,,,,,, -PYR B CLEAR 3MM,StandardGlazing,,0.118110236,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.74,0.09,0.1,0.82,0.11,0.12,0,0.84,0.2,1,FALSE,, -PYR B CLEAR 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.68,0.09,0.1,0.81,0.11,0.12,0,0.84,0.2,1,FALSE,, -R_R30,StandardOpaqueMaterial,Smooth,4.78807,0.15963,30,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -R_R38,StandardOpaqueMaterial,Smooth,6.06489,0.15963,38,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -R_T24_2013_24.86,StandardOpaqueMaterial,Smooth,3.96771,0.15963,24.86,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -R-24 Batt Wall - 8 in. R24,StandardOpaqueMaterial,VeryRough,8,0.3336,23.98081535,1.19,0.23,,,,,,,,,,,,,,,,,,,,, -R1_R14.20,StandardOpaqueMaterial,Smooth,2.26635,0.15963,14.2,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -R2_R12.90,StandardOpaqueMaterial,Smooth,2.05887,0.15963,12.9,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -R3_R17.74,StandardOpaqueMaterial,Smooth,2.83134,0.15963,17.74,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -R4_R20.28,StandardOpaqueMaterial,Smooth,3.23667,0.15963,20.28,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -Rammed Earth,StandardOpaqueMaterial,Rough,18,1.4796,12.16545012,115,0.2,,,,,,,,,,,,,,,,,,,,, -REF A CLEAR LO 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.066,0.341,0.493,0.08,0.41,0.37,0,0.84,0.4,1,FALSE,, -REF A CLEAR MID 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.11,0.27,0.43,0.14,0.31,0.35,0,0.84,0.47,1,FALSE,, -REF A TINT MID 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.06,0.13,0.42,0.09,0.14,0.35,0,0.84,0.47,1,FALSE,, -REF B CLEAR HI 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.24,0.16,0.32,0.3,0.16,0.29,0,0.84,0.6,1,FALSE,, -REF B CLEAR LO 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.15,0.22,0.38,0.2,0.23,0.33,0,0.84,0.58,1,FALSE,, -REF B TINT HI 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.15,0.09,0.33,0.18,0.08,0.28,0,0.84,0.6,1,FALSE,, -REF B TINT MID 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.1,0.11,0.41,0.13,0.1,0.32,0,0.84,0.45,1,FALSE,, -REF C CLEAR HI 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.2,0.16,0.39,0.22,0.17,0.35,0,0.84,0.55,1,FALSE,, -REF C CLEAR MID 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.17,0.2,0.42,0.19,0.21,0.38,0,0.84,0.51,1,FALSE,, -REF D CLEAR 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.429,0.308,0.379,0.334,0.453,0.505,0,0.84,0.82,1,FALSE,, -REF D TINT 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.3,0.14,0.36,0.25,0.18,0.45,0,0.84,0.82,1,FALSE,, -Roof Gravel - 1 in.,StandardOpaqueMaterial,VeryRough,1,9.9996,0.100004,159.74,0.19,,,,,,,,,,,,,,,,,,,,, -Roof Gravel - 1/2 in.,StandardOpaqueMaterial,VeryRough,0.5,9.9996,0.050002,159.74,0.19,,,,,,,,,,,,,,,,,,,,, -Roof Insulation [18],StandardOpaqueMaterial,MediumRough,6.665354331,0.339740118,19.61897926,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Roof Membrane,StandardOpaqueMaterial,VeryRough,0.374015748,1.109355488,0.337146886,69.99984791,0.348715009,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Roof Membrane - Cool Roof,StandardOpaqueMaterial,VeryRough,0.374015748,1.109355488,0.337146886,69.99984791,0.348715009,0.75,0.37,0.7,,,,,,,,,,,,,,,,,, -Roof Membrane - Highly Reflective,StandardOpaqueMaterial,VeryRough,0.374015748,1.109355488,0.337146886,69.99984791,0.348715009,0.75,0.45,0.7,,,,,,,,,,,,,,,,,, -Roofing felt - 1/8 in.,StandardOpaqueMaterial,VeryRough,0.13,8.3004,0.015661896,141,0.3,,,,,,,,,,,,,,,,,,,,, -Rubber tile - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,0.3396,2.944640754,119,0.48,,,,,,,,,,,,,,,,,,,,, -Sand aggregate - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,5.4504,0.091736386,105,0.2,,,,,,,,,,,,,,,,,,,,, -Sand aggregate - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,5.0796,0.147649421,116,0.2,,,,,,,,,,,,,,,,,,,,, -Sand aggregate - 3/8 in.,StandardOpaqueMaterial,Smooth,0.38,5.1504,0.073780677,116,0.2,,,,,,,,,,,,,,,,,,,,, -Sand aggregate - 5/8 in.,StandardOpaqueMaterial,Smooth,0.63,5.6004,0.112491965,105,0.2,,,,,,,,,,,,,,,,,,,,, -Sand aggregate on metal lath - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,5.7696,0.129991681,105,0.2,,,,,,,,,,,,,,,,,,,,, -Shingles - Asbestos cement - lapped - 1/4 in.,StandardOpaqueMaterial,VeryRough,0.25,1.1904,0.210013441,120,0.24,,,,,,,,,,,,,,,,,,,,, -Shingles - Asphalt roll siding - 1/4 in.,StandardOpaqueMaterial,VeryRough,0.25,1.6704,0.149664751,70,0.36,,,,,,,,,,,,,,,,,,,,, -Shingles - Wood - 16 in. - 7 1/2 in. exposure - 1/2 in.,StandardOpaqueMaterial,MediumRough,0.5,0.57,0.877192982,22,0.31,,,,,,,,,,,,,,,,,,,,, -Shingles - Wood - plus insulated backer board Siding - 5/16 in.,StandardOpaqueMaterial,MediumRough,0.31,0.2196,1.411657559,22,0.31,,,,,,,,,,,,,,,,,,,,, -Siding - Asphalt insulating siding - 1/2 in. bed - 1/2 in.,StandardOpaqueMaterial,VeryRough,0.5,0.3396,1.472320377,70,0.35,,,,,,,,,,,,,,,,,,,,, -Siding - Wood - bevel - 10 in. - lapped - 3/4 in.,StandardOpaqueMaterial,Rough,0.75,0.7104,1.055743243,22,0.28,,,,,,,,,,,,,,,,,,,,, -Simple Glazing,SimpleGlazing,,,,,,,,,,,1.23,0.61,0.25,,,,,,,,,,,,,, -SIPS - Crawl Space - R22 - Double 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.24768,26.24354005,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - Crawl Space - R22 - I Joist Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.23148,28.08017971,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - Crawl Space - R22 - Single 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.23952,27.13760855,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - Crawl Space - R28 - Double 2x Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.25356,32.53667771,5.85,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - Crawl Space - R28 - I Joist Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.2436,33.86699507,5.85,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - Crawl Space - R28 - Single 2x Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.2436,33.86699507,5.85,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - Crawl Space - R33 - Double 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.1842,35.28773073,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - Crawl Space - R33 - I Joist Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.16884,38.49798626,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - Crawl Space - R33 - Single 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.16884,38.49798626,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - Crawl Space - R36 - Double 2x Spline - 10 1/4 in.,StandardOpaqueMaterial,Smooth,10.25,0.26628,38.49331531,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - Crawl Space - R36 - I Joist Spline - 10 1/4 in.,StandardOpaqueMaterial,Smooth,10.25,0.2424,42.28547855,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - Crawl Space - R36 - Single 2x Spline - 10 1/4 in.,StandardOpaqueMaterial,Smooth,10.25,0.25428,40.3098946,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - No Crawl Space - R22 - Double 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.32364,20.084044,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - No Crawl Space - R22 - I Joist Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.29772,21.83259438,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - No Crawl Space - R22 - Single 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.30636,21.21686904,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - No Crawl Space - R28 - Double 2x Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.3144,26.24045802,5.85,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - No Crawl Space - R28 - I Joist Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.29376,28.08415033,5.85,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - No Crawl Space - R28 - Single 2x Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.30408,27.13101815,5.85,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - No Crawl Space - R33 - Double 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.23148,28.08017971,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - No Crawl Space - R33 - I Joist Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.19968,32.55208333,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - No Crawl Space - R33 - Single 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.2076,31.31021195,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - No Crawl Space - R36 - Double 2x Spline - 10 1/4 in.,StandardOpaqueMaterial,Smooth,10.25,0.315,32.53968254,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - No Crawl Space - R36 - I Joist Spline - 10 1/4 in.,StandardOpaqueMaterial,Smooth,10.25,0.2904,35.29614325,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - No Crawl Space - R36 - Single 2x Spline - 10 1/4 in.,StandardOpaqueMaterial,Smooth,10.25,0.2904,35.29614325,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R14 - Double 2x Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.39312,11.44688645,9.89,0.31,,,,,,,,,,,,,,,,,,,,, -SIPS - R14 - I joist Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.35304,12.746431,9.89,0.31,,,,,,,,,,,,,,,,,,,,, -SIPS - R14 - Metal Spline - 48 in.,StandardOpaqueMaterial,Smooth,48,4.14,11.5942029,1.83,0.27,,,,,,,,,,,,,,,,,,,,, -SIPS - R14 - OSB Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.303,14.85148515,9.89,0.31,,,,,,,,,,,,,,,,,,,,, -SIPS - R14 - Single 2x Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.35868,12.54600201,9.89,0.31,,,,,,,,,,,,,,,,,,,,, -SIPS - R18 - Double 2x Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.3306,13.61161525,9.89,0.31,,,,,,,,,,,,,,,,,,,,, -SIPS - R18 - I joist Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.29208,15.40673788,9.89,0.31,,,,,,,,,,,,,,,,,,,,, -SIPS - R18 - OSB Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.25968,17.32902033,9.89,0.31,,,,,,,,,,,,,,,,,,,,, -SIPS - R18 - Single 2x Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.303,14.85148515,9.89,0.31,,,,,,,,,,,,,,,,,,,,, -SIPS - R22 - Double 2x Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.32496,20.00246184,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R22 - Double 2x Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.3828,16.98014629,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R22 - I joist Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.30216,21.51178184,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R22 - I joist Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.33696,19.29012346,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R22 - Metal Spline - 48 in.,StandardOpaqueMaterial,Smooth,48,3.0396,15.79155152,1.83,0.27,,,,,,,,,,,,,,,,,,,,, -SIPS - R22 - OSB Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.28692,22.65439844,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R22 - OSB Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.28452,22.84549417,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R22 - Single 2x Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.3096,20.99483204,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R22 - Single 2x Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.35208,18.46171325,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R28 - Double 2x Spline - 8 1/2 in.,StandardOpaqueMaterial,Smooth,8.5,0.33612,25.28858741,5.71,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R28 - Double 2x Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.37992,21.71509792,5.85,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R28 - I joist Spline - 8 1/2 in.,StandardOpaqueMaterial,Smooth,8.5,0.2976,28.56182796,5.71,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R28 - I joist Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.32364,25.49128661,5.85,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R28 - Metal Spline - 48 in.,StandardOpaqueMaterial,Smooth,48,2.45688,19.53697372,1.83,0.27,,,,,,,,,,,,,,,,,,,,, -SIPS - R28 - OSB Spline - 8 1/2 in.,StandardOpaqueMaterial,Smooth,8.5,0.2976,28.56182796,5.71,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R28 - OSB Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.27768,29.71045808,5.85,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R28 - Single 2x Spline - 8 1/2 in.,StandardOpaqueMaterial,Smooth,8.5,0.3072,27.66927083,5.71,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R28 - Single 2x Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.34236,24.09744129,5.85,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R33 - Double 2x Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.23484,27.67841935,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R33 - Double 2x Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.29928,21.71879177,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R33 - I joist Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.213,30.51643192,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R33 - I joist Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.24768,26.24354005,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R33 - OSB Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.2058,31.5840622,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R33 - OSB Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.21876,29.71292741,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R33 - Single 2x Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.213,30.51643192,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R33 - Single 2x Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.26232,24.778896,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R36 - Double 2x Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.31308,32.73923598,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R36 - Double 2x Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.3792,27.03059072,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R36 - I joist Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.2904,35.29614325,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R36 - I joist Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.32244,31.78885994,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R36 - Metal Spline - 48 in.,StandardOpaqueMaterial,Smooth,48,2.2296,21.5285253,1.83,0.27,,,,,,,,,,,,,,,,,,,,, -SIPS - R36 - OSB Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.27912,36.72255661,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R36 - OSB Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.27756,36.9289523,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R36 - Single 2x Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.30168,33.97639883,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R36 - Single 2x Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.345,29.71014493,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R44 - Double 2x Spline - 12 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,12.25,0.32016,38.26211894,4.27,0.28,,,,,,,,,,,,,,,,,,,,, -SIPS - R44 - Double 2x Spline - 12 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,12.25,0.35844,34.17587323,4.27,0.28,,,,,,,,,,,,,,,,,,,,, -SIPS - R44 - I joist Spline - 12 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,12.25,0.2802,43.71877231,4.27,0.28,,,,,,,,,,,,,,,,,,,,, -SIPS - R44 - I joist Spline - 12 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,12.25,0.31848,38.46395378,4.27,0.28,,,,,,,,,,,,,,,,,,,,, -SIPS - R44 - OSB Spline - 12 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,12.25,0.267,45.88014981,4.27,0.28,,,,,,,,,,,,,,,,,,,,, -SIPS - R44 - OSB Spline - 12 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,12.25,0.279,43.90681004,4.27,0.28,,,,,,,,,,,,,,,,,,,,, -SIPS - R44 - Single 2x Spline - 12 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,12.25,0.29352,41.73480512,4.27,0.28,,,,,,,,,,,,,,,,,,,,, -SIPS - R44 - Single 2x Spline - 12 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,12.25,0.34512,35.49490032,4.27,0.28,,,,,,,,,,,,,,,,,,,,, -SIPS - R55 - Double 2x Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.22344,45.8736126,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R55 - Double 2x Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.3,34.16666667,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R55 - I joist Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.19044,53.82272632,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R55 - I joist Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.2334,43.91602399,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R55 - OSB Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.17952,57.09670232,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R55 - OSB Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.21156,48.4496124,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R55 - Single 2x Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.20136,50.90385379,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R55 - Single 2x Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.25548,40.12055738,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -Skylight_Frame_Width_0.000_in,,,,,0,,,,,,,,,,,,,,,,,,,,,,0, -Skylight_Frame_Width_0.334_in,,,,,0.02,,,,,,,,,,,,,,,,,,,,,,0.334, -Skylight_Frame_Width_0.430_in,,,,,0.02,,,,,,,,,,,,,,,,,,,,,,0.43, -Skylight_Frame_Width_0.709_in,,,,,0.02,,,,,,,,,,,,,,,,,,,,,,0.709, -Skylight_Frame_Width_2.339_in,,,,,0.02,,,,,,,,,,,,,,,,,,,,,,2.339, -Slate - 1/2 in.,StandardOpaqueMaterial,VeryRough,0.5,11.0304,0.045329272,119.81,0.3,,,,,,,,,,,,,,,,,,,,, -Slate or tile - 1/2 in.,StandardOpaqueMaterial,VeryRough,0.5,11.0304,0.045329272,119.81,0.3,,,,,,,,,,,,,,,,,,,,, -Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 3 1/2 in.,StandardOpaqueMaterial,Rough,3.5,0.3204,10.92384519,4.6,0.34,,,,,,,,,,,,,,,,,,,,, -Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 4 1/2 in.,StandardOpaqueMaterial,Rough,4.5,0.3204,14.04494382,4.6,0.34,,,,,,,,,,,,,,,,,,,,, -Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 4 in.,StandardOpaqueMaterial,Rough,4,0.3204,12.48439451,4.6,0.34,,,,,,,,,,,,,,,,,,,,, -Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 5 1/2 in.,StandardOpaqueMaterial,Rough,5.5,0.3204,17.16604245,4.6,0.34,,,,,,,,,,,,,,,,,,,,, -Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 5 in.,StandardOpaqueMaterial,Rough,5,0.3204,15.60549313,4.6,0.34,,,,,,,,,,,,,,,,,,,,, -Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 6 1/2 in.,StandardOpaqueMaterial,Rough,6.5,0.3204,20.28714107,4.6,0.34,,,,,,,,,,,,,,,,,,,,, -Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 6 in.,StandardOpaqueMaterial,Rough,6,0.3204,18.72659176,4.6,0.34,,,,,,,,,,,,,,,,,,,,, -Spray applied - Glass fiber - 3.9 lb/ft3 - 3 1/2 in.,StandardOpaqueMaterial,MediumRough,3.5,0.27,12.96296296,3.9,0.23,,,,,,,,,,,,,,,,,,,,, -Spray applied - Glass fiber - 3.9 lb/ft3 - 4 1/2 in.,StandardOpaqueMaterial,MediumRough,4.5,0.27,16.66666667,3.9,0.23,,,,,,,,,,,,,,,,,,,,, -Spray applied - Glass fiber - 3.9 lb/ft3 - 4 in.,StandardOpaqueMaterial,MediumRough,4,0.27,14.81481481,3.9,0.23,,,,,,,,,,,,,,,,,,,,, -Spray applied - Glass fiber - 3.9 lb/ft3 - 5 1/2 in.,StandardOpaqueMaterial,MediumRough,5.5,0.27,20.37037037,3.9,0.23,,,,,,,,,,,,,,,,,,,,, -Spray applied - Glass fiber - 3.9 lb/ft3 - 5 in.,StandardOpaqueMaterial,MediumRough,5,0.27,18.51851852,3.9,0.23,,,,,,,,,,,,,,,,,,,,, -Spray applied - Glass fiber - 3.9 lb/ft3 - 6 1/2 in.,StandardOpaqueMaterial,MediumRough,6.5,0.27,24.07407407,3.9,0.23,,,,,,,,,,,,,,,,,,,,, -Spray applied - Glass fiber - 3.9 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,0.27,22.22222222,3.9,0.23,,,,,,,,,,,,,,,,,,,,, -Spray applied - Polyurethane foam - 0.5 lb/ft3 - 3 1/2 in.,StandardOpaqueMaterial,Rough,3.5,0.3,11.66666667,0.5,0.35,,,,,,,,,,,,,,,,,,,,, -Spray applied - Polyurethane foam - 0.5 lb/ft3 - 4 1/2 in.,StandardOpaqueMaterial,Rough,4.5,0.3,15,0.5,0.35,,,,,,,,,,,,,,,,,,,,, -Spray applied - Polyurethane foam - 0.5 lb/ft3 - 4 in.,StandardOpaqueMaterial,Rough,4,0.3,13.33333333,0.5,0.35,,,,,,,,,,,,,,,,,,,,, -Spray applied - Polyurethane foam - 0.5 lb/ft3 - 5 1/2 in.,StandardOpaqueMaterial,Rough,5.5,0.3,18.33333333,0.5,0.35,,,,,,,,,,,,,,,,,,,,, -Spray applied - Polyurethane foam - 0.5 lb/ft3 - 5 in.,StandardOpaqueMaterial,Rough,5,0.3,16.66666667,0.5,0.35,,,,,,,,,,,,,,,,,,,,, -Spray applied - Polyurethane foam - 0.5 lb/ft3 - 6 1/2 in.,StandardOpaqueMaterial,Rough,6.5,0.3,21.66666667,0.5,0.35,,,,,,,,,,,,,,,,,,,,, -Spray applied - Polyurethane foam - 0.5 lb/ft3 - 6 in.,StandardOpaqueMaterial,Rough,6,0.3,20,0.5,0.35,,,,,,,,,,,,,,,,,,,,, -Spray applied - Polyurethane foam - 3.0 lb/ft3 - 3 1/2 in.,StandardOpaqueMaterial,Rough,3.5,0.20004,17.4965007,3,0.35,,,,,,,,,,,,,,,,,,,,, -Spray applied - Polyurethane foam - 3.0 lb/ft3 - 4 1/2 in.,StandardOpaqueMaterial,Rough,4.5,0.20004,22.4955009,3,0.35,,,,,,,,,,,,,,,,,,,,, -Spray applied - Polyurethane foam - 3.0 lb/ft3 - 4 in.,StandardOpaqueMaterial,Rough,4,0.20004,19.9960008,3,0.35,,,,,,,,,,,,,,,,,,,,, -Spray applied - Polyurethane foam - 3.0 lb/ft3 - 5 1/2 in.,StandardOpaqueMaterial,Rough,5.5,0.20004,27.4945011,3,0.35,,,,,,,,,,,,,,,,,,,,, -Spray applied - Polyurethane foam - 3.0 lb/ft3 - 5 in.,StandardOpaqueMaterial,Rough,5,0.20004,24.995001,3,0.35,,,,,,,,,,,,,,,,,,,,, -Spray applied - Polyurethane foam - 3.0 lb/ft3 - 6 1/2 in.,StandardOpaqueMaterial,Rough,6.5,0.20004,32.4935013,3,0.35,,,,,,,,,,,,,,,,,,,,, -Spray applied - Polyurethane foam - 3.0 lb/ft3 - 6 in.,StandardOpaqueMaterial,Rough,6,0.20004,29.9940012,3,0.35,,,,,,,,,,,,,,,,,,,,, -Std Wood 6 in.,StandardOpaqueMaterial,MediumSmooth,5.905511811,0.832016616,7.097829176,33.71109871,0.289003535,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Std Wood 6inch Furnishings,StandardOpaqueMaterial,MediumSmooth,5.91,0.83257,,33.71,0.29,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Steel Frame NonRes Wall Insulation-0.73,StandardOpaqueMaterial,MediumRough,0.79835618,0.339740118,2.34990258,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Steel Frame Wall Insulation R-1.02 IP,StandardOpaqueMaterial,MediumRough,0.347890885,0.339740118,1.023991182,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Steel Frame/Cavity,StandardOpaqueMaterial,MediumRough,3.500007095,0.583217221,6.001206697,40.03997387,0.119919749,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Stone - 1 in.,StandardOpaqueMaterial,MediumRough,1,12.504,0.079974408,139.78,0.22,,,,,,,,,,,,,,,,,,,,, -Straw Bale - Int and Ext Stucco - 18 in.,StandardOpaqueMaterial,Smooth,19.5,0.6504,29.98154982,12.95,0.11,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Double glass with no low e coatings - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.81,2.802469136,29.09,0.26,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Double glass with no low e coatings - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.5304,6.165158371,20.44,0.26,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Double glass with no low e coatings - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.64764,6.901982583,15.23,0.27,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Double glass with no low e coatings - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,0.7704,7.359813084,12.22,0.27,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Double glass with no low e coatings - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,0.8904,7.715633423,10.26,0.27,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Double glass with no low e coatings - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.02,7.911764706,8.88,0.27,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Double glass with no low e coatings - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.39,4.692307692,35.69,0.26,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Double glass with no low e coatings - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.4596,5.548302872,25.92,0.26,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Single glass pane. stone. or metal pane - No Ins.,StandardOpaqueMaterial,Smooth,2.52,1.2804,1.968134958,41.9,0.26,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Single glass pane. stone. or metal pane - R10 Ins.,StandardOpaqueMaterial,Smooth,3.52,0.5904,5.962059621,30.2,0.26,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Single glass pane. stone. or metal pane - R15 Ins.,StandardOpaqueMaterial,Smooth,4.72,0.6996,6.746712407,22.79,0.26,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Single glass pane. stone. or metal pane - R20 Ins.,StandardOpaqueMaterial,Smooth,5.92,0.81324,7.27952388,18.37,0.26,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Single glass pane. stone. or metal pane - R25 Ins.,StandardOpaqueMaterial,Smooth,7.12,0.93372,7.625412329,15.45,0.27,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Single glass pane. stone. or metal pane - R30 Ins.,StandardOpaqueMaterial,Smooth,8.32,1.05,7.923809524,13.37,0.27,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Single glass pane. stone. or metal pane - R4 Ins.,StandardOpaqueMaterial,Smooth,2.08,0.48624,4.277722935,50.36,0.25,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Single glass pane. stone. or metal pane - R7 Ins.,StandardOpaqueMaterial,Smooth,2.8,0.5304,5.279034691,37.69,0.26,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Triple or low e glass - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.6504,3.490159902,29.09,0.26,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Triple or low e glass - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.51,6.411764706,20.44,0.26,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Triple or low e glass - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.63636,7.024325853,15.23,0.27,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Triple or low e glass - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,0.76476,7.414090695,12.22,0.27,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Triple or low e glass - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,0.88404,7.771141577,10.26,0.27,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Triple or low e glass - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.0104,7.986935867,8.88,0.27,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Triple or low e glass - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.36,5.083333333,35.69,0.26,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Triple or low e glass - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.43836,5.8171366,25.92,0.26,,,,,,,,,,,,,,,,,,,,, -Stucco - 3/8 in.,StandardOpaqueMaterial,Smooth,0.38,5.0004,0.07599392,115.81,0.2,,,,,,,,,,,,,,,,,,,,, -Stucco - 7/8 in.,StandardOpaqueMaterial,Smooth,0.88,4.86,0.181069959,115.81,0.2,,,,,,,,,,,,,,,,,,,,, -Stucco - 7/8 in. CBES,StandardOpaqueMaterial,MediumRough,0.88,4.85668,,115.81,0.2,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -Synthetic Stucco - EIFS finish - 1 in.,StandardOpaqueMaterial,Smooth,1,0.2496,4.006410256,1.5,0.35,,,,,,,,,,,,,,,,,,,,, -Terrazzo - 1 in.,StandardOpaqueMaterial,Rough,1,12.5004,0.07999744,160,0.19,,,,,,,,,,,,,,,,,,,,, -Test,Test,Test,0.1,0.1,0.1,0.1,0.1,0.1,0.1,0.1,,,,,,,,,,,,,,,,,, -Theoretical Glass [167],StandardGlazing,,0.118110236,14.61090512,0.06844203,,,,,,,,,,SpectralAverage,0.2374,0.7126,0.7126,0.2512,0.6988,0.6988,0,0.985,0.985,1,FALSE,, -Theoretical Glass [197],StandardGlazing,,0.118110236,0.28773908,3.475370816,,,,,,,,,,SpectralAverage,0.2349,0.7151,0.7151,0.2512,0.6988,0.6988,0,0.9,0.9,1,FALSE,, -Theoretical Glass [202],StandardGlazing,,0.118110236,0.133122659,7.511869212,,,,,,,,,,SpectralAverage,0.2325,0.7175,0.7175,0.3192,0.6308,0.6308,0,0.9,0.9,1,FALSE,, -Theoretical Glass [207],StandardGlazing,,0.118110236,0.092215175,10.84420217,,,,,,,,,,SpectralAverage,0.3311,0.6189,0.6189,0.44,0.51,0.51,0,0.9,0.9,1,FALSE,, -Theoretical Glass [216],StandardGlazing,,0.118110236,0.092215175,10.84420217,,,,,,,,,,SpectralAverage,0.3801,0.5699,0.5699,0.5079,0.4421,0.4421,0,0.9,0.9,1,FALSE,, -Theoretical Glass [221],StandardGlazing,,0.118110236,0.061707899,16.20538077,,,,,,,,,,SpectralAverage,0.4296,0.5204,0.5204,0.4503,0.4997,0.4997,0,0.9,0.9,1,FALSE,, -Theoretical Glass 297,StandardGlazing,,0.118110236,0.071803727,13.92685363,,,,,,,,,,SpectralAverage,0.375039,0.574961,0.574961,0.529698,0.420302,0.420302,0,0.9,0.9,1,FALSE,, -Theoretical Glass 347,StandardGlazing,,0.118110236,0.071816901,13.92429898,,,,,,,,,,SpectralAverage,0.315861,0.634139,0.634139,0.479911,0.470089,0.470089,0,0.9,0.9,1,FALSE,, -Tile Gap - 3/4 in.,StandardOpaqueMaterial,VeryRough,0.75,0.6612,1.13430127,70,0.24,,,,,,,,,,,,,,,,,,,,, -Typical Air Wall,MasslessOpaqueMaterial,,,6.240124619,0.16025321,0.043699572,0.000167192,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Typical Carpet Pad,MasslessOpaqueMaterial,VeryRough,,,1.229230374,,,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -Typical Insulation,MasslessOpaqueMaterial,MediumSmooth,,6.240124619,0.16025321,0.043699572,0.000167192,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -U 0.11 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.11,0.34,0.374,,,,,,,,,,,,,, -U 0.11 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.11,0.38,0.418,,,,,,,,,,,,,, -U 0.12 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.12,0.34,0.374,,,,,,,,,,,,,, -U 0.12 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.12,0.38,0.418,,,,,,,,,,,,,, -U 0.13 SHGC 0.32 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.13,0.32,0.352,,,,,,,,,,,,,, -U 0.13 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.13,0.38,0.418,,,,,,,,,,,,,, -U 0.14 SHGC 0.31 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.14,0.31,0.341,,,,,,,,,,,,,, -U 0.14 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.14,0.34,0.374,,,,,,,,,,,,,, -U 0.14 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.14,0.36,0.396,,,,,,,,,,,,,, -U 0.14 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.14,0.38,0.418,,,,,,,,,,,,,, -U 0.15 SHGC 0.31 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.15,0.31,0.341,,,,,,,,,,,,,, -U 0.15 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.15,0.34,0.374,,,,,,,,,,,,,, -U 0.17 SHGC 0.31 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.17,0.31,0.341,,,,,,,,,,,,,, -U 0.17 SHGC 0.32 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.17,0.32,0.352,,,,,,,,,,,,,, -U 0.17 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.17,0.36,0.396,,,,,,,,,,,,,, -U 0.18 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.18,0.22,0.242,,,,,,,,,,,,,, -U 0.18 SHGC 0.24 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.18,0.24,0.264,,,,,,,,,,,,,, -U 0.20 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.2,0.19,0.209,,,,,,,,,,,,,, -U 0.20 SHGC 0.20 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.2,0.2,0.22,,,,,,,,,,,,,, -U 0.20 SHGC 0.21 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.2,0.21,0.231,,,,,,,,,,,,,, -U 0.20 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.2,0.22,0.242,,,,,,,,,,,,,, -U 0.23 SHGC 0.31 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.23,0.31,0.341,,,,,,,,,,,,,, -U 0.23 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.23,0.34,0.374,,,,,,,,,,,,,, -U 0.25 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.25,0.22,0.242,,,,,,,,,,,,,, -U 0.25 SHGC 0.24 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.25,0.24,0.264,,,,,,,,,,,,,, -U 0.26 SHGC 0.40 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.26,0.4,0.44,,,,,,,,,,,,,, -U 0.29 SHGC 0.40 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.29,0.4,0.44,,,,,,,,,,,,,, -U 0.32 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.32,0.36,0.396,,,,,,,,,,,,,, -U 0.35 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.35,0.22,0.242,,,,,,,,,,,,,, -U 0.35 SHGC 0.24 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.35,0.24,0.264,,,,,,,,,,,,,, -U 0.42 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.42,0.34,0.374,,,,,,,,,,,,,, -U 0.45 SHGC 0.33 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.45,0.33,0.363,,,,,,,,,,,,,, -U 0.47 SHGC 0.33 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.47,0.33,0.363,,,,,,,,,,,,,, -U 0.48 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.48,0.19,0.209,,,,,,,,,,,,,, -U 0.48 SHGC 0.21 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.48,0.21,0.231,,,,,,,,,,,,,, -U 0.48 SHGC 0.20 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.48,0.2,0.22,,,,,,,,,,,,,, -U 0.48 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.48,0.22,0.242,,,,,,,,,,,,,, -U 0.50 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.22,0.242,,,,,,,,,,,,,, -U 0.50 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.23,0.253,,,,,,,,,,,,,, -U 0.52 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.52,0.39,0.31,,,,,,,,,,,,,, -U 0.52 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.52,0.49,0.41,,,,,,,,,,,,,, -U 0.52 SHGC 0.615 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.52,0.615,0.41,,,,,,,,,,,,,, -U 0.54 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.54,0.23,0.253,,,,,,,,,,,,,, -U 0.58 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.58,0.19,0.15,,,,,,,,,,,,,, -U 0.58 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.58,0.36,0.25,,,,,,,,,,,,,, -U 0.59 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.59,0.36,0.27,,,,,,,,,,,,,, -U 0.59 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.59,0.39,0.31,,,,,,,,,,,,,, -U 0.60 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.6,0.23,0.253,,,,,,,,,,,,,, -U 0.61 SHGC 0.77 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.61,0.77,0.6,,,,,,,,,,,,,, -U 0.62 SHGC 0.20 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.62,0.2,0.22,,,,,,,,,,,,,, -U 0.62 SHGC 0.21 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.62,0.21,0.231,,,,,,,,,,,,,, -U 0.62 SHGC 0.41 Simple Glazing,SimpleGlazing,1.22,0.54,0.38,,,,,,,,0.62,0.41,0.32,,,,,,,,,,,,,, -U 0.65 SHGC 0.35 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.65,0.35,0.25,,,,,,,,,,,,,, -U 0.69 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.69,0.19,0.15,,,,,,,,,,,,,, -U 0.69 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.69,0.36,0.23,,,,,,,,,,,,,, -U 0.69 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.69,0.39,0.23,,,,,,,,,,,,,, -U 0.69 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.69,0.49,0.38,,,,,,,,,,,,,, -U 0.69 SHGC 0.64 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.69,0.64,0.55,,,,,,,,,,,,,, -U 0.69 SHGC 0.68 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.69,0.68,0.55,,,,,,,,,,,,,, -U 0.72 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.72,0.25,0.13,,,,,,,,,,,,,, -U 0.72 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.72,0.36,0.23,,,,,,,,,,,,,, -U 0.72 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.72,0.39,0.23,,,,,,,,,,,,,, -U 0.74 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.74,0.55,0.4,,,,,,,,,,,,,, -U 0.74 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.74,0.65,0.55,,,,,,,,,,,,,, -U 0.75 SHGC 0.35 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.35,0.23,,,,,,,,,,,,,, -U 0.81 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.81,0.65,0.55,,,,,,,,,,,,,, -U 0.85 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.85,0.65,0.55,,,,,,,,,,,,,, -U 0.87 SHGC 0.58 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.87,0.58,0.55,,,,,,,,,,,,,, -U 0.87 SHGC 0.71 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.87,0.71,0.6,,,,,,,,,,,,,, -U 0.87 SHGC 0.77 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.87,0.77,0.6,,,,,,,,,,,,,, -U 0.98 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.19,0.15,,,,,,,,,,,,,, -U 0.98 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.36,0.25,,,,,,,,,,,,,, -U 1.10 SHGC 0.62 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.1,0.62,0.55,,,,,,,,,,,,,, -U 1.10 SHGC 0.77 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.1,0.77,0.6,,,,,,,,,,,,,, -U 1.15 SHGC 0.77 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.15,0.77,0.6,,,,,,,,,,,,,, -U 1.17 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.17,0.19,0.15,,,,,,,,,,,,,, -U 1.17 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.17,0.36,0.23,,,,,,,,,,,,,, -U 1.17 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.17,0.39,0.23,,,,,,,,,,,,,, -U 1.17 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.17,0.49,0.38,,,,,,,,,,,,,, -U 1.17 SHGC 0.64 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.17,0.64,0.55,,,,,,,,,,,,,, -U 1.17 SHGC 0.68 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.17,0.68,0.55,,,,,,,,,,,,,, -U 1.22 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.25,0.11,,,,,,,,,,,,,, -U 1.22 SHGC 0.54 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.54,0.38,,,,,,,,,,,,,, -U 1.30 SHGC 0.27 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.3,0.27,0.25,,,,,,,,,,,,,, -U 1.30 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.3,0.34,0.25,,,,,,,,,,,,,, -U 1.30 SHGC 0.62 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.3,0.62,0.55,,,,,,,,,,,,,, -U 1.30 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.3,0.65,0.55,,,,,,,,,,,,,, -U 1.36 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.36,0.19,0.15,,,,,,,,,,,,,, -U 1.36 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.36,0.36,0.23,,,,,,,,,,,,,, -U 1.36 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.36,0.39,0.23,,,,,,,,,,,,,, -U 1.36 SHGC 0.61 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.36,0.61,0.23,,,,,,,,,,,,,, -U 1.70 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.7,0.36,0.23,,,,,,,,,,,,,, -U 1.80 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.8,0.36,0.23,,,,,,,,,,,,,, -U 1.90 SHGC 0.27 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.9,0.27,0.25,,,,,,,,,,,,,, -U 1.90 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.9,0.34,0.25,,,,,,,,,,,,,, -U 1.90 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.9,0.39,0.25,,,,,,,,,,,,,, -U 1.90 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.9,0.65,0.25,,,,,,,,,,,,,, -U 1.98 SHGC 0.16 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.16,0.15,,,,,,,,,,,,,, -U 1.98 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.19,0.15,,,,,,,,,,,,,, -U 1.98 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.36,0.25,,,,,,,,,,,,,, -U 1.98 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.39,0.25,,,,,,,,,,,,,, -U 1.98 SHGC 0.61 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.61,0.25,,,,,,,,,,,,,, -U0.47_SHGC_0.49_SimpleGlazing_Window_05,SimpleGlazing,,,,,,,,,,Air,0.47,0.49,0.81,,,,,,,,,,,,,, -U0.47_SHGC0.46_SimpleGlazing_Window_07,SimpleGlazing,,,,,,,,,,Air,0.47,0.46,0.81,,,,,,,,,,,,,, -U0.47_SHGC0.47_SimpleGlazing_Window_06,SimpleGlazing,,,,,,,,,,Air,0.47,0.47,0.81,,,,,,,,,,,,,, -U0.47_SHGC0.47_SimpleGlazing_Window_11,SimpleGlazing,,,,,,,,,,Air,0.47,0.47,0.81,,,,,,,,,,,,,, -U0.47_SHGC0.5_SimpleGlazing_Window_03,SimpleGlazing,,,,,,,,,,Air,0.47,0.5,0.81,,,,,,,,,,,,,, -U0.77_SHGC_0.77_SimpleGlazing_Window_02,SimpleGlazing,,,,,,,,,,Air,0.77,0.77,0.81,,,,,,,,,,,,,, -U0.77_SHGC0.5_SimpleGlazing_Window_09,SimpleGlazing,,,,,,,,,,Air,0.77,0.5,0.81,,,,,,,,,,,,,, -U0.77_SHGC0.61_SimpleGlazing_Window_08,SimpleGlazing,,,,,,,,,,Air,0.77,0.61,0.81,,,,,,,,,,,,,, -U0.77_SHGC0.62_SimpleGlazing_Window_04,SimpleGlazing,,,,,,,,,,Air,0.77,0.62,0.81,,,,,,,,,,,,,, -U1.23_SHGC0.5_SimpleGlazing_Window_12,SimpleGlazing,,,,,,,,,,Air,1.23,0.5,0.81,,,,,,,,,,,,,, -U1.23_SHGC0.82_SimpleGlazing_Window_01,SimpleGlazing,,,,,,,,,,Air,1.23,0.82,0.81,,,,,,,,,,,,,, -U1.23_SHGC0.82_SimpleGlazing_Window_10,SimpleGlazing,,,,,,,,,,Air,1.23,0.62,0.81,,,,,,,,,,,,,, -Vapor permeable felt - 1/8 in.,StandardOpaqueMaterial,Rough,0.13,2.0796,0.062512022,22,0.3,,,,,,,,,,,,,,,,,,,,, -Vapor seal - 2 layers of mopped 15 lb felt - 1/4 in.,StandardOpaqueMaterial,Rough,0.25,2.0796,0.120215426,22,0.3,,,,,,,,,,,,,,,,,,,,, -Vapor seal - plastic film - 1/16 in.,StandardOpaqueMaterial,Rough,0.63,62.4996,0.010080065,30,0.3,,,,,,,,,,,,,,,,,,,,, -Vermiculite aggregate - 45 lb/ft3 - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,1.7004,0.294048459,45,0.32,,,,,,,,,,,,,,,,,,,,, -W_m1_R15,StandardOpaqueMaterial,Smooth,2.39403,0.15963,15,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -W_m2_R19,StandardOpaqueMaterial,Smooth,3.03244,0.15963,19,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -W_m3_R21,StandardOpaqueMaterial,Smooth,3.35165,0.15963,21,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -W_T24_2013_R13.99,StandardOpaqueMaterial,Smooth,2.23284,0.15963,13.99,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -W1_R8.60,StandardOpaqueMaterial,Smooth,1.37252,0.15963,8.6,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -W2_R11.13,StandardOpaqueMaterial,Smooth,1.77634,0.15963,11.13,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -W3_R11.36,StandardOpaqueMaterial,Smooth,1.81305,0.15963,11.36,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -W4_R12.62,StandardOpaqueMaterial,Smooth,2.01414,0.15963,12.62,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -Wall Insulation [31],StandardOpaqueMaterial,MediumRough,1.326771654,0.299525982,4.429571171,5.680944412,0.199914015,0.9,0.5,0.5,,,,,,,,,,,,,,,,,, -Wood - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,1.0404,0.961168781,37.94,0.39,,,,,,,,,,,,,,,,,,,,, -Wood - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,1.0404,0.480584391,37.94,0.39,,,,,,,,,,,,,,,,,,,,, -Wood - 2 in.,StandardOpaqueMaterial,MediumSmooth,2,1.0404,1.922337562,37.94,0.39,,,,,,,,,,,,,,,,,,,,, -Wood - 4 in.,StandardOpaqueMaterial,MediumSmooth,4,1.0404,3.844675125,37.94,0.39,,,,,,,,,,,,,,,,,,,,, -Wood Frame NonRes Wall Insulation-0.73,StandardOpaqueMaterial,MediumRough,0.79835618,0.339740118,2.34990258,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Wood Frame Wall Insulation R-1.61 IP,StandardOpaqueMaterial,MediumRough,0.54621365,0.339740118,1.607739625,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x10 - R11 ins.,MasslessOpaqueMaterial,,,,10.783,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x10 - R13 ins.,MasslessOpaqueMaterial,,,,12.4765,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x10 - R19 ins.,MasslessOpaqueMaterial,,,,17.1561,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x10 - R21 ins.,MasslessOpaqueMaterial,,,,18.5953,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x10 - R22 ins.,MasslessOpaqueMaterial,,,,19.2942,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,21.3129,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,24.4379,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x10 - R38 ins.,MasslessOpaqueMaterial,,,,28.8982,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x10 - R44 ins.,MasslessOpaqueMaterial,,,,31.873,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x10 - R49 ins.,MasslessOpaqueMaterial,,,,34.1444,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x10 - R60 ins.,MasslessOpaqueMaterial,,,,38.5802,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x12 - R11 ins.,MasslessOpaqueMaterial,,,,11.0136,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x12 - R13 ins.,MasslessOpaqueMaterial,,,,12.7862,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x12 - R19 ins.,MasslessOpaqueMaterial,,,,17.7471,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x12 - R21 ins.,MasslessOpaqueMaterial,,,,19.2917,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x12 - R22 ins.,MasslessOpaqueMaterial,,,,20.045,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x12 - R25 ins.,MasslessOpaqueMaterial,,,,22.2328,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x12 - R30 ins.,MasslessOpaqueMaterial,,,,25.6551,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,30.6158,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x12 - R44 ins.,MasslessOpaqueMaterial,,,,33.9752,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x12 - R49 ins.,MasslessOpaqueMaterial,,,,36.5684,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x12 - R60 ins.,MasslessOpaqueMaterial,,,,41.7037,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,9.0352,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,10.1946,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x4 - R19 ins.,MasslessOpaqueMaterial,,,,13.1185,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x4 - R21 ins.,MasslessOpaqueMaterial,,,,13.9437,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x4 - R22 ins.,MasslessOpaqueMaterial,,,,14.333,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x4 - R25 ins.,MasslessOpaqueMaterial,,,,15.4178,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x4 - R30 ins.,MasslessOpaqueMaterial,,,,16.9895,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x4 - R38 ins.,MasslessOpaqueMaterial,,,,19.0316,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x4 - R44 ins.,MasslessOpaqueMaterial,,,,20.278,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x4 - R49 ins.,MasslessOpaqueMaterial,,,,21.1742,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x4 - R60 ins.,MasslessOpaqueMaterial,,,,22.7998,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,9.98167,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,11.416,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,15.2129,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,16.3338,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x6 - R22 ins.,MasslessOpaqueMaterial,,,,16.8706,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x6 - R25 ins.,MasslessOpaqueMaterial,,,,18.394,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x6 - R30 ins.,MasslessOpaqueMaterial,,,,20.6759,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x6 - R38 ins.,MasslessOpaqueMaterial,,,,23.7814,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x6 - R44 ins.,MasslessOpaqueMaterial,,,,25.7599,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x6 - R49 ins.,MasslessOpaqueMaterial,,,,27.2236,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x6 - R60 ins.,MasslessOpaqueMaterial,,,,29.9711,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x8 - R11 ins.,MasslessOpaqueMaterial,,,,10.4438,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x8 - R13 ins.,MasslessOpaqueMaterial,,,,12.0246,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,16.313,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x8 - R21 ins.,MasslessOpaqueMaterial,,,,17.6089,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,18.2344,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x8 - R25 ins.,MasslessOpaqueMaterial,,,,20.0271,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x8 - R30 ins.,MasslessOpaqueMaterial,,,,22.7622,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x8 - R38 ins.,MasslessOpaqueMaterial,,,,26.584,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x8 - R44 ins.,MasslessOpaqueMaterial,,,,29.0808,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x8 - R49 ins.,MasslessOpaqueMaterial,,,,30.96,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x8 - R60 ins.,MasslessOpaqueMaterial,,,,34.5633,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x10 - R11 ins.,MasslessOpaqueMaterial,,,,10.8472,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x10 - R13 ins.,MasslessOpaqueMaterial,,,,12.6291,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x10 - R19 ins.,MasslessOpaqueMaterial,,,,17.6705,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x10 - R21 ins.,MasslessOpaqueMaterial,,,,19.2568,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x10 - R22 ins.,MasslessOpaqueMaterial,,,,20.0334,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,22.2995,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,25.8772,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x10 - R38 ins.,MasslessOpaqueMaterial,,,,31.1355,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x10 - R44 ins.,MasslessOpaqueMaterial,,,,34.7459,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x10 - R49 ins.,MasslessOpaqueMaterial,,,,37.5607,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x10 - R60 ins.,MasslessOpaqueMaterial,,,,43.2077,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x12 - R11 ins.,MasslessOpaqueMaterial,,,,11.0095,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x12 - R13 ins.,MasslessOpaqueMaterial,,,,12.8496,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x12 - R19 ins.,MasslessOpaqueMaterial,,,,18.1053,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x12 - R21 ins.,MasslessOpaqueMaterial,,,,19.7743,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x12 - R22 ins.,MasslessOpaqueMaterial,,,,20.594,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x12 - R25 ins.,MasslessOpaqueMaterial,,,,22.9964,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x12 - R30 ins.,MasslessOpaqueMaterial,,,,26.8204,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,32.5111,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x12 - R44 ins.,MasslessOpaqueMaterial,,,,36.4678,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x12 - R49 ins.,MasslessOpaqueMaterial,,,,39.581,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x12 - R60 ins.,MasslessOpaqueMaterial,,,,45.903,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,9.54677,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,10.9003,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x4 - R19 ins.,MasslessOpaqueMaterial,,,,14.4614,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x4 - R21 ins.,MasslessOpaqueMaterial,,,,15.5068,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x4 - R22 ins.,MasslessOpaqueMaterial,,,,16.0065,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x4 - R25 ins.,MasslessOpaqueMaterial,,,,17.421,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x4 - R30 ins.,MasslessOpaqueMaterial,,,,19.5305,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x4 - R38 ins.,MasslessOpaqueMaterial,,,,22.3835,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x4 - R44 ins.,MasslessOpaqueMaterial,,,,24.1906,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x4 - R49 ins.,MasslessOpaqueMaterial,,,,25.5222,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x4 - R60 ins.,MasslessOpaqueMaterial,,,,28.0096,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,10.2668,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,11.8491,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,16.1804,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,17.5004,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x6 - R22 ins.,MasslessOpaqueMaterial,,,,18.1394,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x6 - R25 ins.,MasslessOpaqueMaterial,,,,19.9777,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x6 - R30 ins.,MasslessOpaqueMaterial,,,,22.802,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x6 - R38 ins.,MasslessOpaqueMaterial,,,,26.7885,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x6 - R44 ins.,MasslessOpaqueMaterial,,,,29.4185,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x6 - R49 ins.,MasslessOpaqueMaterial,,,,31.4116,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x6 - R60 ins.,MasslessOpaqueMaterial,,,,35.2661,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x8 - R11 ins.,MasslessOpaqueMaterial,,,,10.6047,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x8 - R13 ins.,MasslessOpaqueMaterial,,,,12.3015,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,17.0358,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x8 - R21 ins.,MasslessOpaqueMaterial,,,,18.5054,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,19.2214,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x8 - R25 ins.,MasslessOpaqueMaterial,,,,21.298,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x8 - R30 ins.,MasslessOpaqueMaterial,,,,24.5383,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x8 - R38 ins.,MasslessOpaqueMaterial,,,,29.2172,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x8 - R44 ins.,MasslessOpaqueMaterial,,,,32.3739,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x8 - R49 ins.,MasslessOpaqueMaterial,,,,34.804,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x8 - R60 ins.,MasslessOpaqueMaterial,,,,39.5997,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 16inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,21.3129,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 16inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,24.4379,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 16inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,30.6158,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 16inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,9.98167,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 16inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,11.416,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 16inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,15.2129,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 16inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,16.313,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 16inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,18.2344,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 24inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,22.2995,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 24inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,25.8772,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 24inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,32.5111,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 24inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,10.2668,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 24inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,11.8491,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 24inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,16.1804,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 24inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,17.0358,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 24inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,19.2214,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x10 - R22 ins.,MasslessOpaqueMaterial,,,,19.2942,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,21.3129,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,24.4379,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x12 - R30 ins.,MasslessOpaqueMaterial,,,,25.6551,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,30.6158,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x14 - R38 ins.,MasslessOpaqueMaterial,,,,30.6158,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,9.0352,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,10.1946,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,11.2537,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x4 - R19 ins.,MasslessOpaqueMaterial,,,,13.1185,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,9.98167,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,11.416,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x6 - R15 ins.,MasslessOpaqueMaterial,,,,12.7607,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,15.2129,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,16.3338,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,16.313,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x8 - R21 ins.,MasslessOpaqueMaterial,,,,17.6089,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x10 - R22 ins.,MasslessOpaqueMaterial,,,,20.0334,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,22.2995,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,25.8772,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x12 - R30 ins.,MasslessOpaqueMaterial,,,,26.8204,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,32.5111,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x14 - R38 ins.,MasslessOpaqueMaterial,,,,32.5111,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,9.54677,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,10.9003,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,12.1652,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x4 - R19 ins.,MasslessOpaqueMaterial,,,,14.4614,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,10.2668,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,11.8491,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x6 - R15 ins.,MasslessOpaqueMaterial,,,,13.359,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,16.1804,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,17.5004,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,17.0358,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x8 - R21 ins.,MasslessOpaqueMaterial,,,,18.5054,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 16inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,7.12596,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 16inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,7.70165,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 16inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,8.18665,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 16inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,11.7113,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 16inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,12.2507,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 16inOC - 2x6 - R22 ins.,MasslessOpaqueMaterial,,,,12.4993,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 16inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,13.4581,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 16inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,14.5092,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 16inOC - 2x8 - R25 ins.,MasslessOpaqueMaterial,,,,15.4247,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 16inOC - 2x8 - R30 ins.,MasslessOpaqueMaterial,,,,16.7137,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,7.44041,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x4 - R11 ins. AWS,MasslessOpaqueMaterial,,,,8.03106,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,8.09769,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x4 - R13 ins. AWS,MasslessOpaqueMaterial,,,,8.85675,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,8.6586,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x4 - R15 ins. AWS,MasslessOpaqueMaterial,,,,9.57897,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,12.2765,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x6 - R19 ins. AWS,MasslessOpaqueMaterial,,,,13.3502,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,12.8954,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x6 - R21 ins. AWS,MasslessOpaqueMaterial,,,,14.1353,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x6 - R22 ins.,MasslessOpaqueMaterial,,,,13.1824,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x6 - R22 ins. AWS,MasslessOpaqueMaterial,,,,14.5036,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,13.9462,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x8 - R19 ins. AWS,MasslessOpaqueMaterial,,,,14.8435,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,15.1272,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x8 - R22 ins. AWS,MasslessOpaqueMaterial,,,,16.2834,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x8 - R25 ins.,MasslessOpaqueMaterial,,,,16.1678,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x8 - R25 ins. AWS,MasslessOpaqueMaterial,,,,17.5793,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x8 - R30 ins.,MasslessOpaqueMaterial,,,,17.6518,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x8 - R30 ins. AWS,MasslessOpaqueMaterial,,,,19.4735,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 48inOC - 2x4 - R11 ins. AWS,MasslessOpaqueMaterial,,,,10.1197,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 48inOC - 2x4 - R13 ins. AWS,MasslessOpaqueMaterial,,,,11.711,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 48inOC - 2x4 - R15 ins. AWS,MasslessOpaqueMaterial,,,,13.2373,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 48inOC - 2x6 - R19 ins. AWS,MasslessOpaqueMaterial,,,,17.2794,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 48inOC - 2x6 - R21 ins. AWS,MasslessOpaqueMaterial,,,,18.8464,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 48inOC - 2x6 - R22 ins. AWS,MasslessOpaqueMaterial,,,,19.6146,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 48inOC - 2x8 - R19 ins. AWS,MasslessOpaqueMaterial,,,,17.8255,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 48inOC - 2x8 - R22 ins. AWS,MasslessOpaqueMaterial,,,,20.3213,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 48inOC - 2x8 - R25 ins. AWS,MasslessOpaqueMaterial,,,,22.7412,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 48inOC - 2x8 - R30 ins. AWS,MasslessOpaqueMaterial,,,,26.6149,,,,,,,,,,,,,,,,,,,,,,, -Wood shingles - 3/4 in.,StandardOpaqueMaterial,VeryRough,0.75,0.8304,0.903179191,36.94,0.31,,,,,,,,,,,,,,,,,,,,, -Wood shingles - plain and plastic film faced - 3/4 in.,StandardOpaqueMaterial,VeryRough,0.75,0.8004,0.937031484,22,0.31,,,,,,,,,,,,,,,,,,,,, -Wood Siding,StandardOpaqueMaterial,MediumSmooth,0.393700787,0.762681898,0.516205758,33.99951589,0.289003535,0.9,0.78,0.78,,,,,,,,,,,,,,,,,, -Wood siding - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,0.6204,0.805931657,36.94,0.28,,,,,,,,,,,,,,,,,,,,, -U 0.49 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.49,0.22,,,,,,,,,,,,,,, -U 0.57 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.57,0.25,,,,,,,,,,,,,,, -U 0.53 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.53,0.25,,,,,,,,,,,,,,, -U 0.48 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.48,0.25,,,,,,,,,,,,,,, -U 0.38 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.38,0.36,,,,,,,,,,,,,,, -U 0.38 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.38,0.38,,,,,,,,,,,,,,, -U 0.36 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.36,0.4,,,,,,,,,,,,,,, -U 0.33 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.33,0.45,,,,,,,,,,,,,,, -U 0.29 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.29,0.45,,,,,,,,,,,,,,, -U 0.5 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.22,,,,,,,,,,,,,,, -U 0.54 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.54,0.25,,,,,,,,,,,,,,, -U 0.49 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.49,0.25,,,,,,,,,,,,,,, -U 0.45 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.45,0.25,,,,,,,,,,,,,,, -U 1.19 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.19,0.45,,,,,,,,,,,,,,, -U 0.73 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.73,0.45,,,,,,,,,,,,,,, -U 0.62 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.62,0.45,,,,,,,,,,,,,,, -U 0.51 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.51,0.45,,,,,,,,,,,,,,, -U 0.38 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.38,0.45,,,,,,,,,,,,,,, -U 0.53 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.53,0.22,,,,,,,,,,,,,,, -U 0.53 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.53,0.23,,,,,,,,,,,,,,, -U 0.38 SHGC 0.35 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.38,0.35,,,,,,,,,,,,,,, -U 0.38 SHGC 0.37 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.38,0.37,,,,,,,,,,,,,,, -U 0.36 SHGC 0.37 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.36,0.37,,,,,,,,,,,,,,, -U 0.31 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.31,0.39,,,,,,,,,,,,,,, -U 0.28 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.28,0.39,,,,,,,,,,,,,,, -U 0.51 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.51,0.22,,,,,,,,,,,,,,, -U 0.51 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.51,0.23,,,,,,,,,,,,,,, -U 0.46 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.46,0.25,,,,,,,,,,,,,,, -U 0.43 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.43,0.25,,,,,,,,,,,,,,, -U 0.36 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.36,0.36,,,,,,,,,,,,,,, -U 0.36 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.36,0.38,,,,,,,,,,,,,,, -U 0.34 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.34,0.38,,,,,,,,,,,,,,, -U 0.29 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.29,0.4,,,,,,,,,,,,,,, -U 0.26 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.26,0.4,,,,,,,,,,,,,,, -U 0.37 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.37,0.36,,,,,,,,,,,,,,, -U 0.37 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.37,0.38,,,,,,,,,,,,,,, -U 0.35 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.35,0.38,,,,,,,,,,,,,,, -U 0.3 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.3,0.4,,,,,,,,,,,,,,, -U 0.27 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.27,0.4,,,,,,,,,,,,,,, -U 0.5 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.23,,,,,,,,,,,,,,, -U 0.42 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.42,0.25,,,,,,,,,,,,,,, -U 0.47 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.47,0.25,,,,,,,,,,,,,,, -U 1.2 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.2,0.45,,,,,,,,,,,,,,, -U 0.5 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.45,,,,,,,,,,,,,,, -U 0.39 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.39,0.45,,,,,,,,,,,,,,, -U 0.36 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.36,0.45,,,,,,,,,,,,,,, -U 0.75 SHGC 0.35 Simple Glazing Window,SimpleGlazing,,,,,,,,,,,0.75,0.35,,,,,,,,,,,,,,, -U 0.65 SHGC 0.35 Simple Glazing Window,SimpleGlazing,,,,,,,,,,,0.65,0.35,,,,,,,,,,,,,,, -U 0.55 SHGC 0.35 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.55,0.35,,,,,,,,,,,,,,, -U 0.5 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.4,,,,,,,,,,,,,,, -U 0.5 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.55,,,,,,,,,,,,,,, -U 0.41 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.41,0.55,,,,,,,,,,,,,,, -U 1.8 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.8,0.55,,,,,,,,,,,,,,, -U 1.7 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.7,0.55,,,,,,,,,,,,,,, -U 1.15 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.15,0.55,,,,,,,,,,,,,,, -U 0.98 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.55,,,,,,,,,,,,,,, -U 0.85 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.85,0.55,,,,,,,,,,,,,,, -U 0.7 SHGC 0.3 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.7,0.3,,,,,,,,,,,,,,, -U 0.65 SHGC 0.3 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.65,0.3,,,,,,,,,,,,,,, -U 0.55 SHGC 0.3 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.55,0.3,,,,,,,,,,,,,,, -U 0.47 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.47,0.4,,,,,,,,,,,,,,, -U 0.44 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.44,0.55,,,,,,,,,,,,,,, -U 0.9 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.9,0.55,,,,,,,,,,,,,,, -U 0.75 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.55,,,,,,,,,,,,,,, -U 0.37 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.37,0.25,,,,,,,,,,,,,,, -U 0.83 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.83,0.25,,,,,,,,,,,,,,, -U 0.77 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.77,0.25,,,,,,,,,,,,,,, -U 0.93 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.93,0.45,,,,,,,,,,,,,,, -U 0.83 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.83,0.45,,,,,,,,,,,,,,, -U 0.65 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.65,0.55,,,,,,,,,,,,,,, -U 1.8 SHGC 0.77 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.8,0.77,,,,,,,,,,,,,,, -U 0.65 SHGC 0.77 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.65,0.77,,,,,,,,,,,,,,, -U 0.65 SHGC 0.68 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.65,0.68,,,,,,,,,,,,,,, -U 1.8 SHGC 0.64 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.8,0.64,,,,,,,,,,,,,,, -U 0.33 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.33,0.25,,,,,,,,,,,,,,, -U 0.68 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.68,0.25,,,,,,,,,,,,,,, -U 0.87 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.87,0.45,,,,,,,,,,,,,,, -U 0.77 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.77,0.45,,,,,,,,,,,,,,, -U 0.55 SHGC 0.64 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.55,0.64,,,,,,,,,,,,,,, -U 0.55 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.55,0.55,,,,,,,,,,,,,,, -U 0.31 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.31,0.36,,,,,,,,,,,,,,, -U 0.68 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.68,0.36,,,,,,,,,,,,,,, -U 0.31 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.31,0.38,,,,,,,,,,,,,,, -U 0.68 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.68,0.38,,,,,,,,,,,,,,, -U 0.45 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.45,0.45,,,,,,,,,,,,,,, -U 0.5 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.36,,,,,,,,,,,,,,, -U 0.5 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.19,,,,,,,,,,,,,,, -U 0.5 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.34,,,,,,,,,,,,,,, -U 0.98 SHGC 0.27 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.27,,,,,,,,,,,,,,, -U 0.98 SHGC 0.36 Simple Glazing Weighted,SimpleGlazing,,,,,,,,,,,0.98,0.36,,,,,,,,,,,,,,, -U 0.68 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.68,0.4,,,,,,,,,,,,,,, -U 0.85 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.85,0.19,,,,,,,,,,,,,,, -U 0.85 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.85,0.39,,,,,,,,,,,,,,, -U 0.28 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.28,0.45,,,,,,,,,,,,,,, -U 0.68 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.68,0.45,,,,,,,,,,,,,,, -U 0.32 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.32,0.45,,,,,,,,,,,,,,, -U 0.5 SHGC 0.27 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.27,,,,,,,,,,,,,,, -U 0.25 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.25,0.45,,,,,,,,,,,,,,, -U 0.5 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.39,,,,,,,,,,,,,,, -U 0.5 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.65,,,,,,,,,,,,,,, -U 0.85 SHGC 0.27 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.85,0.27,,,,,,,,,,,,,,, -U 0.5 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.25,,,,,,,,,,,,,,, -U 1.1 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.1,0.25,,,,,,,,,,,,,,, -U 1.1 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.1,0.45,,,,,,,,,,,,,,, -U 0.75 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.49,,,,,,,,,,,,,,, -U 1.8 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.8,0.49,,,,,,,,,,,,,,, -U 0.75 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.39,,,,,,,,,,,,,,, -U 0.75 SHGC 0.68 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.68,,,,,,,,,,,,,,, -U 0.75 SHGC 0.64 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.64,,,,,,,,,,,,,,, -U 0.77 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.77,0.23,,,,,,,,,,,,,,, -U 0.68 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.68,0.23,,,,,,,,,,,,,,, -U 0.63 SHGC 0.33 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.63,0.33,,,,,,,,,,,,,,, -U 0.63 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.63,0.34,,,,,,,,,,,,,,, -U 0.63 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.63,0.36,,,,,,,,,,,,,,, -U 0.63 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.63,0.45,,,,,,,,,,,,,,, -U 0.83 SHGC 0.21 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.83,0.21,,,,,,,,,,,,,,, -U 0.32 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.32,0.22,,,,,,,,,,,,,,, -U 0.83 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.83,0.22,,,,,,,,,,,,,,, -U 0.83 SHGC 0.2 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.83,0.2,,,,,,,,,,,,,,, -U 0.6 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.6,0.23,,,,,,,,,,,,,,, -U 0.62 SHGC 0.2 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.62,0.2,,,,,,,,,,,,,,, -U 1.22 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.19,,,,,,,,,,,,,,, -U 1.22 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.45,,,,,,,,,,,,,,, -U 1.22 SHGC 0.17 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.17,,,,,,,,,,,,,,, -U 1.22 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.39,,,,,,,,,,,,,,, -U 0.98 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.45,,,,,,,,,,,,,,, -U 1.98 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.45,,,,,,,,,,,,,,, -U 0.57 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.57,0.39,,,,,,,,,,,,,,, -U 0.46 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.46,0.19,,,,,,,,,,,,,,, -U 1.98 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.34,,,,,,,,,,,,,,, -U 1.22 SHGC 0.61 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.61,,,,,,,,,,,,,,, -U 1.22 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.34,,,,,,,,,,,,,,, -U 0.57 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.57,0.49,,,,,,,,,,,,,,, -U 0.46 SHGC 0.26 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.46,0.26,,,,,,,,,,,,,,, -U 1.98 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.65,,,,,,,,,,,,,,, -U 0.58 SHGC 0.61 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.58,0.61,,,,,,,,,,,,,,, -U 0.46 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.46,0.36,,,,,,,,,,,,,,, -U 0.46 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.46,0.45,,,,,,,,,,,,,,, -U 0.35 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.35,0.45,,,,,,,,,,,,,,, -U 0.98 SHGC 0.62 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.62,,,,,,,,,,,,,,, -U 0.58 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.58,0.45,,,,,,,,,,,,,,, -U 0.75 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.25,,,,,,,,,,,,,,, -U 0.7 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.7,0.25,,,,,,,,,,,,,,, -U 1.98 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.49,,,,,,,,,,,,,,, -U 0.65 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.65,0.25,,,,,,,,,,,,,,, -U 0.6 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.6,0.25,,,,,,,,,,,,,,, -U 0.9 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.9,0.25,,,,,,,,,,,,,,, -U 1.98 SHGC 0.71 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.71,,,,,,,,,,,,,,, -U 0.4 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.4,0.4,,,,,,,,,,,,,,, -U 0.55 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.55,0.4,,,,,,,,,,,,,,, -U 0.85 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.85,0.4,,,,,,,,,,,,,,, -U 0.35 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.35,0.4,,,,,,,,,,,,,,, -U 0.45 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.45,0.4,,,,,,,,,,,,,,, -U 0.8 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.8,0.4,,,,,,,,,,,,,,, -U 0.65 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.65,0.45,,,,,,,,,,,,,,, -U 0.6 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.6,0.45,,,,,,,,,,,,,,, -U 0.9 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.9,0.45,,,,,,,,,,,,,,, -U 0.4 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.4,0.45,,,,,,,,,,,,,,, -U 0.8 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.8,0.45,,,,,,,,,,,,,,, -U 1.2 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.2,0.25,,,,,,,,,,,,,,, -U 1.98 SHGC 0.27 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.27,,,,,,,,,,,,,,, -U 1.17 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.17,0.45,,,,,,,,,,,,,,, -U 0.98 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.49,,,,,,,,,,,,,,, -U 0.98 SHGC 0.46 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.46,,,,,,,,,,,,,,, -U 0.58 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.58,0.65,,,,,,,,,,,,,,, -U 0.58 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.58,0.55,,,,,,,,,,,,,,, -U 0.4 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.4,0.25,,,,,,,,,,,,,,, -U 0.35 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.35,0.25,,,,,,,,,,,,,,, -U 0.55 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.55,0.45,,,,,,,,,,,,,,, -U 0.42 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.42,0.4,,,,,,,,,,,,,,, -U 0.77 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.77,0.4,,,,,,,,,,,,,,, -U 0.81 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.81,0.45,,,,,,,,,,,,,,, -U 0.32 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.32,0.4,,,,,,,,,,,,,,, -U 0.7 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.7,0.45,,,,,,,,,,,,,,, -U 0.59 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.59,0.45,,,,,,,,,,,,,,, -U 0.44 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.44,0.45,,,,,,,,,,,,,,, -U 0.93 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.93,0.25,,,,,,,,,,,,,,, -U 0.75 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.45,,,,,,,,,,,,,,, -U 0.48 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.48,0.45,,,,,,,,,,,,,,, diff --git a/data/openstudio_standards_data/initial_data/support_performance_curves.csv b/data/openstudio_standards_data/initial_data/support_performance_curves.csv deleted file mode 100644 index 831e7d15c5..0000000000 --- a/data/openstudio_standards_data/initial_data/support_performance_curves.csv +++ /dev/null @@ -1,734 +0,0 @@ -name,category,form,dependent_variable,independent_variable_1,independent_variable_2,coeff_1,coeff_2,coeff_3,coeff_4,coeff_5,coeff_6,coeff_7,coeff_8,coeff_9,coeff_10,minimum_independent_variable_1,maximum_independent_variable_1,minimum_independent_variable_2,maximum_independent_variable_2,minimum_dependent_variable_output,maximum_dependent_variable_output,annotation -a-Si_Spectral-fAirMass,PV-Module,Cubic,,AirMass,,0.99264449,0.05334853,-0.0372019,0.00327026,,,,,,,,,,,,,From .dat files included with MASControl2 -Absor-1-Cap-fCHWT&ECT,1-StageAbsorptn,BiQuadratic,QRatio,CHWT,ECT,1.757428,0.054774,-0.00290628,-0.035145,-0.000156,0.000894,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Absor-1-HIR-fCHWT&ECT,1-StageAbsorptn,BiQuadratic,,CHWT,ECT,0.691153,0,0,0.005355,0.000178,0,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Absor-1-HIR-fPLR,1-StageAbsorptn,Quadratic,,PLR,,0.087773,0.744921,0.167306,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Absor-2-Cap-fCHWT&ECT,2-StageAbsorptn,BiQuadratic,QRatio,CHWT,ECT,0.362073,0.0001386,0.001458,0.0733878,-0.00206064,0.00101,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Absor-2-HIR-fCHWT&ECT,2-StageAbsorptn,BiQuadratic,,CHWT,ECT,0.98675,0,0,-0.0234,0.00081,0,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Absor-2-HIR-fPLR,2-StageAbsorptn,Quadratic,,PLR,,0.1355115,0.61798084,0.24651277,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -AHU-1_CoolCStandard10Ton_CapFF,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.77136,0.34053,-0.11088,,,,,,,,0.75918,1.13877,,,,,"From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" -AirCooled_Chiller_2004_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.0433811,0.0407077,0.0004506,-0.0041514,-0.0000886,-0.0003467,,,,,5,10,12.7,51.67,,,"Based on Dick Lord's study dated January 17, 2010." -AirCooled_Chiller_2004_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.5961915,-0.0099496,0.0007888,0.0004506,0.0004875,-0.0007623,,,,,5,10,12.7,51.67,,,"Based on Dick Lord's study dated January 17, 2010." -AirCooled_Chiller_2010_PathA_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.0433825,0.0407073,0.0004506,-0.0041514,-0.0000886,-0.0003467,,,,,5,10,12.7,51.67,,,"Based on Dick Lord's study dated January 17, 2010." -AirCooled_Chiller_2010_PathA_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.5961915,-0.0099496,0.0007888,0.0004506,0.0004875,-0.0007623,,,,,5,10,12.7,51.67,,,"Based on Dick Lord's study dated January 17, 2010." -AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.141,0.655,0.203,,,,,,,,0,1,,,,,"Based on Dick Lord's study dated January 17, 2010. EIRFPLR curve is identical for all AirCooled Chillers" -AirCooled_Chiller_GT150_2004_EIRFPLR,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.141,0.655,0.203,,,,,,,,0,1,,,,,"Based on Dick Lord's study dated January 17, 2010." -AirCooled_Chiller_GT150_2010_PathA_EIRFPLR,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.141,0.655,0.203,,,,,,,,0,1,,,,,"Based on Dick Lord's study dated January 17, 2010." -AirCooled_Chiller_LT150_2004_EIRFPLR,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.141,0.655,0.203,,,,,,,,0,1,,,,,"Based on Dick Lord's study dated January 17, 2010." -AirCooled_Chiller_LT150_2010_PathA_EIRFPLR,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.141,0.655,0.203,,,,,,,,0,1,,,,,"Based on Dick Lord's study dated January 17, 2010." -AirFoil w Dischrg Dampers FPLR,FanEIR-FPLR,Quadratic,,PLR,,0.227143,1.178929,-0.410714,,,,,,,,,,,,0.68,1,From .dat files included with MASControl2 -AirFoil w Inlet Vanes FPLR,FanEIR-FPLR,Quadratic,,PLR,,0.584345,-0.579167,0.970238,,,,,,,,,,,,0.48,1,From .dat files included with MASControl2 -Atmospheric-Blr-HIR-fPLR,FuelBoilers,Quadratic,,PLR,,0.02699999,1.10549998,-0.13249961,,,,,,,,,,,,,,From .dat files included with MASControl2 -Boiler Constant Efficiency Curve,Boiler,Cubic,FIRRatio,QRatio,,1,0,0,0,,,,,,,0,1,,,,,From DOE Reference Building -Boiler with Minimum Turndown,Boiler,Cubic,FIRRatio,QRatio,,0.7791,1.4745,-2.5795,1.3467,,,,,,,0,1.3,,,,,From Regression of Prototype Building EMS -Boiler with No Minimum Turndown,Boiler,Cubic,FIRRatio,QRatio,,0.7463,1.3196,-2.2154,1.1674,,,,,,,0,1.3,,,,,From Regression of Prototype Building EMS -BOILER-EFFFPLR-NECB2011,Boiler,Cubic,FIRRatio,QRatio,,0.2901,2.6664,-3.764,1.82,,,,,,,0,1,,,,,From NECB 2011 -CdTe_Spectral-fAirMass,PV-Module,Cubic,,AirMass,,0.93700588,0.05130703,-0.00646639,0.00017267,,,,,,,,,,,,,From .dat files included with MASControl2 -CentChlrAirCoolCap-fCHW&OAT,Chiller,BiQuadratic,QRatio,CHWT,OAT,0.94533053,0.068473818,-0.003361694,0.000108108,-0.000225,0.000082,,,,,,,,,,,From .dat files included with MASControl2 -CentChlrAirCoolEIR-fCHW&OAT,Chiller,BiQuadratic,EIRRatio,CHWT,OAT,0.47343824,0.015708042,-0.000948,0.012260718,0.0000955,-0.000352,,,,,,,,,,,From .dat files included with MASControl2 -CentChlrAirCoolEIR-fPLR,Chiller,Quadratic,EIRRatio,PLR,,0.24258,0.41468,0.34273973,,,,,,,,,,,,,,From .dat files included with MASControl2 -CentH2O-Cap-fCHWT&ECT,HermCentrifugal,BiQuadratic,QRatio,CHWT,ECT,0.36460761,-0.030523554,-0.001929776,0.066367926,-0.001891966,0.003110627,,,,,,,,,,,From .dat files included with MASControl2 -CentH2O-EIR-fCHWT&ECT,HermCentrifugal,BiQuadratic,EIRRatio,CHWT,ECT,0.65868459,-0.025336458,0.000991,0.01280322,0.000171,-0.000301,,,,,,,,,,,From .dat files included with MASControl2 -CentH2O-EIR-fPLR&dT,HermCentrifugal,BiQuadratic,EIRRatio,PLR,dT,0.27969646,0.57375735,0.25690463,-0.010452906,0.000475,-0.006354126,,,,,,,,,,,From .dat files included with MASControl2 -CentH2OVSD-Cap-fCHWT&ECT,HermCentrifugal,BiQuadratic,QRatio,CHWT,ECT,0.36211013,-0.032249754,-0.000886,0.066743838,-0.001731488,0.002180358,,,,,,,,,,,From .dat files included with MASControl2 -CentH2OVSD-EIR-fCHWT&ECT,HermCentrifugal,BiQuadratic,EIRRatio,CHWT,ECT,0.41386133,-0.088037676,0.00098,0.056770308,-0.000946,0.001418731,,,,,,,,,,,From .dat files included with MASControl2 -CentH2OVSD-EIR-fPLR&dT,HermCentrifugal,BiQuadratic,EIRRatio,PLR,dT,0.14703037,-0.00349667,1.01161313,-0.006474546,0.00088,-0.020960478,,,,,,,,,,,From .dat files included with MASControl2 -ChillerCentCapFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.7446451,0.0114858,0.0000148,0.022401,-0.000688,0.0009839,,,,,5,10,24,35,,,From Dick Lord's Chiller Model study for ASHRAE 2007 baseline -ChillerCentEIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.772877,0.022101,-0.0000799,-0.0070045,0.0004763,-0.0010612,,,,,5,10,24,35,,,From Dick Lord's Chiller Model study for ASHRAE 2007 baseline -ChillerCentEIRPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,From Dick Lord's Chiller Model study for ASHRAE 2007 baseline -ChlrAirRecipEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.114437,0.545933,0.342299,,,,,,,,0,1,,,0.11,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrAirRecipEIRRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.542784,-0.013907,0.000476,0.012197,0.000149,-0.000334,,,,,4.44,12.22,23.89,46.11,0.72,1.3,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrAirRecipQRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.12603,0.041571,0.000253,-0.010526,0.00001,-0.000256,,,,,4.44,12.22,23.89,46.11,0.82,1.3,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrAirScrewEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.036487,0.734743,0.219947,,,,,,,,0,1,,,0.04,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrAirScrewEIRRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.570624,0.011954,-0.000522,-0.000032,0.000421,-0.000606,,,,,4.44,12.22,23.89,46.11,0.7,1.38,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrAirScrewQRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.985959,0.049487,-0.000298,-0.003737,-0.000045,-0.000502,,,,,4.44,12.22,23.89,46.11,0.82,1.3,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrAirScrollEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.063691,0.584888,0.352803,,,,,,,,0,1,,,0.06,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrAirScrollEIRRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.702194,-0.004466,0.000535,-0.005506,0.000544,-0.000729,,,,,4.44,12.22,23.89,46.11,0.69,1.45,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrAirScrollQRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.02138,0.037021,0.000233,-0.003893,-0.000065,-0.000269,,,,,4.44,12.22,23.89,46.11,0.82,1.3,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrHPAirCoolCap-fCHW&OAT,Chiller,BiQuadratic,QRatio,CHWT,OAT,1.13076899,0.03157983,0.000358,-0.009856332,0.0000101,-0.00015,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPAirCoolEIR-fCHW&OAT,Chiller,BiQuadratic,EIRRatio,CHWT,OAT,0.5637406,-0.009225918,0.000353,0.009452178,0.000187,-0.000314,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPAirHeatCap-fHW&39-,Chiller,BiQuadratic,QRatio,HW,39,0.92141508,-0.003413682,-0.00000386,0.0324,0.000611,-0.0000518,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPAirHeatCap-fHW&39+,Chiller,BiQuadratic,QRatio,HW,39+,0.94069023,-0.004035888,0.000000421,0.046218906,-0.001703171,-0.000000227,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPAirHeatEIR-fHW&39-,Chiller,BiQuadratic,EIRRatio,HW,39,0.33398382,0.019817694,0.000012,0.0048024,-0.0000332,-0.000898,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPAirHeatEIR-fHW&39+,Chiller,BiQuadratic,EIRRatio,HW,39+,0.38886863,0.018107262,0.0000194,-0.026683668,0.002056655,-0.000499,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPH2OCoolCap_fCHW&ECT,Chiller/HP,BiQuadratic,QRatio,CHWT,ECT,35.68362061,0.62273101,-0.005677932,-0.248948775,-0.003461286,0.011142622,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPH2OCoolCap_fCHW&ECT-Old,Chiller/HP,BiQuadratic,QRatio,CHWT,ECT,0.96601399,0.04050054,0.000589,-0.008098668,0.0000665,-0.000454,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPH2OCoolEIR_fCHW&ECT,Chiller/HP,BiQuadratic,EIRRatio,CHWT,ECT,0.111287472,-0.002094557,0.000201,0.00170532,0.000168,-0.000308,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPH2OCoolEIR_fCHW&ECT-Old,Chiller/HP,BiQuadratic,EIRRatio,CHWT,ECT,0.61092869,-0.016352352,0.000407,0.003044232,0.000592,-0.000668,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPH2OHeatCap_fHWS&EET,Chiller/HP,BiQuadratic,QRatio,HWS,EET,29.914016,0.1544256,-0.0041472,0.6832512,-0.00203148,0.00199584,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPH2OHeatCap_fHWS&EET-Old,Chiller/HP,BiQuadratic,QRatio,HWS,EET,0.84649612,-0.00264807,0.0000231,0.02700126,0.00013,-0.000127,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPH2OHeatEIR_fHWS&EET,Chiller/HP,BiQuadratic,EIRRatio,HWS,EET,0.12004,-0.00011232,0.0000985,-0.00107928,0.0000732,-0.000134,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPH2OHeatEIR_fHWS&EET-Old,Chiller/HP,BiQuadratic,EIRRatio,HWS,EET,0.2068226,0.018812142,0.000105,-0.012659724,0.000406,-0.000399,,,,,,,,,,,From .dat files included with MASControl2 -ChlrWtrCentPathAAllEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.222149,0.503156,0.256905,,,,,,,,0.1,1,,,0.28,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrCentPathAAllEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.658643,-0.025339,0.000991,0.012801,0.000171,-0.000301,,,,,4.44,12.22,15.56,29.44,0.68,1.05,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrCentPathAAllQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.364691,-0.030521,-0.00193,0.066374,-0.001892,0.003111,,,,,4.44,12.22,15.56,29.44,0.87,0.91,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrCentPathBGtEql300Lt600tonEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.055483,0.451866,0.488242,,,,,,,,0.1,1,,,0.11,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrCentPathBGtEql300Lt600tonEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.756376,-0.015019,0.000156,0.00246,0.000515,-0.000687,,,,,4.44,12.22,15.56,29.44,0.63,1.12,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrCentPathBGtEql300Lt600tonQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,1.35608,0.04875,-0.000888,-0.014525,-0.000286,-0.00004,,,,,4.44,12.22,15.56,29.44,0.87,1.52,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrCentPathBGtEql600tonEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.107426,0.156775,0.739345,,,,,,,,0.1,1,,,0.13,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrCentPathBGtEql600tonEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.737625,0.001456,-0.000223,0.007116,0.000267,-0.000735,,,,,4.44,12.22,15.56,29.44,0.76,1.08,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrCentPathBGtEql600tonQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.854454,0.042526,-0.000185,0.011697,-0.000497,-0.000412,,,,,4.44,12.22,15.56,29.44,0.9,1.33,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrCentPathBLt300tonEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.208389,-0.121404,0.918455,,,,,,,,0.1,1,,,0.21,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrCentPathBLt300tonEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.711108,-0.023515,0.001194,0.017737,0.000152,-0.001159,,,,,4.44,12.22,15.56,29.44,0.69,1.13,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrCentPathBLt300tonQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,1.15508,0.036503,-0.000499,-0.001455,-0.000439,-0.000172,,,,,4.44,12.22,15.56,29.44,0.86,1.37,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.310965,0.322519,0.372745,,,,,,,,0.1,1,,,0.35,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.665307,-0.009339,0.000483,0.009492,0.000544,-0.000864,,,,,4.44,12.22,15.56,29.44,0.74,1.27,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.96744,0.037082,0.000434,-0.005837,-0.000049,-0.000274,,,,,4.44,12.22,15.56,29.44,0.89,1.33,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrPosDispPathBAllEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0,0.6206,0.3893,,,,,,,,0.1,1,,,0.07,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrPosDispPathBAllEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.428265,-0.024071,0.000849,0.016416,0.000381,-0.00059,,,,,4.44,12.22,15.56,29.44,0.5,1.07,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrPosDispPathBAllQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.899926,0.030102,-0.000332,-0.001743,-0.000092,0.000229,,,,,4.44,12.22,15.56,29.44,0.93,1.21,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CHW-Coil-Cap-fAirflow,CHWCoils,Quadratic,QRatio,Airflow,,0.0488,1.38,-0.425,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -CHW-Coil-Cap-fEWB&EWT,CHWCoils,BiQuadratic,QRatio,EWB,EWT,1.6726784,-0.13378464,0.0065124,0.03828096,0.0000826,-0.005868936,,,,,15.55556,29.44444,4.44444,18.33333,,,From .dat files included with MASControl2 -CHW-Coil-Cap-fFluidFlow,CHWCoils,Quadratic,QRatio,FluidFlow,,0.218,3199.5088,-3280000,,,,,,,,0,1,,,,,From .dat files included with MASControl2 -Coffin Defrost Curve,Refrigerated Case,Cubic,,,,0.3475,0.0296,0.0007,0.00003,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings -Coffin Latent Curve,Refrigerated Case,Cubic,,,,0.3379,0.0309,0.0005,0.00004,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings -COIL-BF-FFLOW-SPEC,CoilBF-FFLOW,Linear,,Flow,,0.33,1419.6496,,,,,,,,,,,,,0.8,,From .dat files included with MASControl2 -Coil-Bypass-Factor-fPLR,CHWCoils,Linear,QRatio,PLR,,1,0,,,,,,,,,,,,,,,From .dat files included with MASControl2 -CoilClgDXDblEIRRatio_fCFMRatio,DX Cooling Coil,Cubic,EIRRatio,FlowRatio,,1.007948,0.345441,-0.692289,0.338899,,,,,,,0,1,,,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgDXDblQRatio_fCFMRatio,DX Cooling Coil,Cubic,QRatio,FlowRatio,,0.472786,1.243342,-1.038706,0.322578,,,,,,,-100,100,0.47,,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgDXEIRRatio_fQFrac,DX Cooling Coil,Cubic,EIRRatio,QRatio,,0,5.1091,-8.5515,4.4744,,,,,,,0.7,1,0.92,1,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgDXEIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.116709,0.028458,-0.000411,0.021422,0.000162,-0.00068,,,,,13.89,25,23.89,46.11,0.77,1.33,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgDXQRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.86779,0.014245,0.000554,-0.007569,0.000032,-0.000191,,,,,13.89,25,23.89,46.11,0.77,1.29,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgDXSEER13EER11EIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,-0.199992,-0.035686,0.000787,0.074834,-0.000516,-0.000573,,,,,13.89,25,23.89,46.11,0.55,1.44,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgDXSEER15EER11EIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,-1.790474,-0.028777,0.000763,0.153391,-0.001482,-0.000721,,,,,13.89,25,23.89,46.11,0.35,1.42,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgDXSEER16EER13EIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.686684,-0.035826,0.000781,0.025564,0.000163,-0.000559,,,,,13.89,25,23.89,46.11,0.65,1.51,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgDXSEER17EER11EIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,-3.060538,-0.023207,0.000744,0.216093,-0.002253,-0.000839,,,,,13.89,25,23.89,46.11,0.2,1.4,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgDXSEER18EER13EIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,-1.247121,-0.027513,0.000752,0.121123,-0.001013,-0.000736,,,,,13.89,25,23.89,46.11,0.41,1.48,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgDXSEER20EER13EIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,-2.72492,-0.02112,0.00073,0.194128,-0.001911,-0.000872,,,,,13.89,25,23.89,46.11,0.23,1.45,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgDXSEEREIRRatio_fQFrac,DX Cooling Coil,Cubic,EIRRatio,QRatio,,1,0,0,0,,,,,,,0.7,1,1,1,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgDXSnglEIRRatio_fCFMRatio,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.156,-0.1816,0.0256,,,,,,,,0,1,,,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgDXSnglQRatio_fCFMRatio,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgPTACEIRRatio_fQFrac,DX Cooling Coil,Cubic,EIRRatio,QRatio,,0.85,0.15,0,0,,,,,,,0.7,1,0.96,1,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgPTACEIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.341434,0.03481,-0.000625,0.004941,0.000437,-0.000729,,,,,13.89,25,23.89,46.11,0.75,1.4,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgPTACQRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.942879,0.009538,0.000684,-0.011002,0.000006,-0.00001,,,,,13.89,25,23.89,46.11,0.71,1.34,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ConstantCubic,,Cubic,,,,1,0,0,0,,,,,,,-100,100,,,,,From Reference Buildings -Cool-PLF-fPLR,DX Cooling Coil,Quadratic,EIRRatio,QRatio,,0.90949556,0.09864773,-0.00819488,,,,,,,,0,1,,,,,From PNNL Prototype FullServiceRestaurant -CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.2055,-0.32953,0.12308,,,,,,,,0.75918,1.13877,,,,,"From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" -Curve_Biquadratic_CBES_01,,BiQuadratic,,,,0.86779,0.014245,0.000554,-0.007569,0.000032,-0.000191,,,,,0,100,0,100,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov -Curve_Biquadratic_CBES_02,,BiQuadratic,,,,-0.199992,-0.035686,0.000787,0.074834,-0.000516,-0.000573,,,,,13.9,25,23.9,43.3,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov -Curve_Biquadratic_CBES_03,,BiQuadratic,,,,0.9425878,0.00954335,0.00068377,-0.0110427,0.00000525,-0.00000972,,,,,17,22,13,46,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov -Curve_Biquadratic_CBES_04,,BiQuadratic,,,,0.3424144,0.03488501,-0.0006237,0.00497722,0.00043795,-0.000728,,,,,17,22,13,46,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov -Curve_Quadratic_CBES_01,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov -Curve_Quadratic_CBES_02,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.156,-0.1816,0.0256,,,,,,,,0.5,1.5,,,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov -Curve_Quadratic_CBES_03,,Quadratic,,,,1,0,0,,,,,,,,0,1,,,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov -Curve_Quadratic_CBES_04,,Quadratic,,,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov -Curve_Quadratic_CBES_05,,Quadratic,,,,1.1552,-0.1808,0.0256,,,,,,,,0.5,1.5,,,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov -Curve_Quadratic_CBES_06,,Quadratic,,,,0.85,0.15,0,,,,,,,,0,1,,,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov -DEER DHW HIR-FPLR Curve,DEERDHWHIR-FPLR,Linear,,PLR,,0,1,,,,,,,,,,,,,,,From .dat files included with MASControl2 -DEER_defrost,Refrigeration,Cubic,,,,0.023632,0.0006232,0.00002832,4.4035E-07,,,,,,,-23,7,,,,, -DEER_Heat_Rejections_LT,Refrigeration,Linear,Capacity,DeltaT,,0,16383.61446,,,,,,,,,-100,100,,,,,From eQuest Grocery store model -DEER_Heat_Rejections_MT,Refrigeration,Linear,Capacity,DeltaT,,0,20626.34211,,,,,,,,,-100,100,,,,,From eQuest Grocery store model -Default_Case_Latent_Cedit_Curve,Refrigeration,Cubic,,,,0.026526281,0.001078032,-6.02558E-05,1.23732E-06,,,,,,,-35,20,,,,, -Defrost-ResisDem-Frac-fOWB&ODB,DXCool/Heat,BiLinear,QRatio,OWB,ODB,0.0333,0,0,,,,,,,,-23.333,29.444,-23.333,29.444,,,From .dat files included with MASControl2 -Defrost-ResisTime-Frac-fOWB&ODB,DXCool/Heat,BiLinear,QRatio,OWB,ODB,0.0333,0,0,,,,,,,,-23.333,29.444,-23.333,29.444,,,From .dat files included with MASControl2 -Defrost-ReversDem-Frac-fOWB&ODB,DXCool/Heat,BiLinear,QRatio,OWB,ODB,0.0333,0,0,,,,,,,,-23.333,29.444,-23.333,29.444,,,From .dat files included with MASControl2 -Defrost-ReversTime-Frac-fOWB&ODB,DXCool/Heat,BiLinear,QRatio,OWB,ODB,0.0583,0,0,,,,,,,,-23.333,29.444,-23.333,29.444,,,From .dat files included with MASControl2 -Desc-Gas-fT&W,Desiccant,BiQuadratic,,T,W,18784.36736,-3209.524992,-11.8830564,3874.59,-1.69627,-23.53176,,,,,7.22222,46.11111,0,0.1,,,From .dat files included with MASControl2 -Desc-HR8-fWB1&WB6,Desiccant,BiQuadratic,,WB1,WB6,-0.27680768,0.071770464,0.000735,0.145668672,0.000591,-0.002648246,,,,,12.77778,46.11111,12.77778,46.11111,,,From .dat files included with MASControl2 -Desc-HR8PL-fWB1&WB6,Desiccant,BiQuadratic,,WB1,WB6,-0.05234208,0.076111488,0.000502,0.11464641,0.001235315,-0.002453879,,,,,12.77778,46.11111,12.77778,46.11111,,,From .dat files included with MASControl2 -Desc-kW-fT&W,Desiccant,BiQuadratic,,T,W,3.33024,-0.010674,0,0.00404,0,0,,,,,7.22222,46.11111,0,0.1,,,From .dat files included with MASControl2 -Desc-QREG-fWB1&WB6,Desiccant,BiQuadratic,,WB1,WB6,80.58068736,-0.627217344,0.0170748,-2.186211312,0.0000437,0.018960674,,,,,12.77778,40.55556,12.77778,46.11111,,,From .dat files included with MASControl2 -Desc-QREGPL-fWB1&WB6,Desiccant,BiQuadratic,,WB1,WB6,20.30901408,-0.159663744,0.0046008,-0.586622934,-0.00024,0.005206064,,,,,12.77778,46.11111,12.77778,46.11111,,,From .dat files included with MASControl2 -Desc-T-fT&W,Desiccant,BiQuadratic,,T,W,31.53328,1.0173168,-0.0033372,0.295,-0.00017,-0.0015696,,,,,7.22222,46.11111,0,0.1,,,From .dat files included with MASControl2 -Desc-T8-fWB1&WB6,Desiccant,BiLinear,,WB1,WB6,34.64,1.6236,0.2574,,,,,,,,12.77778,46.11111,12.77778,46.11111,,,From .dat files included with MASControl2 -Desc-T8PL-fWB1&WB6,Desiccant,BiLinear,,WB1,WB6,32.7692,1.7496,0.06588,,,,,,,,12.77778,46.11111,12.77778,46.11111,,,From .dat files included with MASControl2 -Desc-W-fT&W,Desiccant,BiQuadratic,,T,W,7.82704,0.119376,0.0144504,0.0831,0.000697,0.002862,,,,,7.22222,46.11111,0,0.1,,,From .dat files included with MASControl2 -Direct-Effectiveness-fFlow,EvapCooler,Quadratic,,Flow,,1.18,-546.67104,333000,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -DOE Ref DX Clg Coil Cool-CAP-fFlow,DX Cooling Coil,Cubic,QRatio,FlowRatio,,1,0,0,0,,,,,,,-100,100,,,,,From DOE Pre-1980 Reference Building -DOE Ref DX Clg Coil Cool-Cap-fT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.9712123,-0.015275502,0.001443452,-0.00039321,-6.8364E-06,-0.000290596,,,,,-100,100,-100,100,,,From DOE Pre-1980 Reference Building -DOE Ref DX Clg Coil Cool-EIR-fFlow,DX Cooling Coil,Cubic,EIRRatio,FlowRatio,,1,0,0,0,,,,,,,-100,100,,,,,From DOE Pre-1980 Reference Building -DOE Ref DX Clg Coil Cool-EIR-fT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.28687133,0.023902164,-0.000810648,0.013458546,0.000338936,-0.000487004,,,,,-100,100,-100,100,,,From DOE Pre-1980 Reference Building -DOE Ref DX Clg Coil Cool-PLF-fPLR,DX Cooling Coil,Quadratic,EIRRatio,QRatio,,0.90949556,0.09864773,-0.00819488,,,,,,,,0,1,,,,, -Draft-Fan-EIR-fPLR,FuelBoilers,Cubic,EIRRatio,PLR,,0.35071223,0.3080535,-0.5413736,0.87198823,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -DW-Elec-EIR-fPLR,ElecDW-Heater,Linear,EIRRatio,PLR,,0,1,,,,,,,,,,,,,,,From .dat files included with MASControl2 -DW-Gas-HIR-fPLR,GasDW-Heater,Quadratic,,PLR,,0.021826,0.97763,0.000543,,,,,,,,,,,,,,From .dat files included with MASControl2 -DW-Gas-Pilotless-HIR-fPLR,GasDW-Heater,Quadratic,,PLR,,0,0.999457,0.000543,,,,,,,,,,,,,,From .dat files included with MASControl2 -DW-HeatPump-Cap-fSupplyT&EDB,HeatPumpDW-Heat,BiQuadratic,QRatio,SupplyT,EDB,0.74922298,0,0,0.028130328,0.000236,0,,,,,,,,,,,From .dat files included with MASControl2 -DW-HeatPump-EIR-fPLR,HeatPumpDW-Heat,Cubic,EIRRatio,PLR,,0.08565215,0.93881371,-0.1834361,0.15897022,,,,,,,,,,,,,From .dat files included with MASControl2 -DW-HeatPump-EIR-fSupplyT&EDB,HeatPumpDW-Heat,BiQuadratic,EIRRatio,SupplyT,EDB,1.25311702,0,0,-0.033921486,0.000426,0,,,,,,,,,,,From .dat files included with MASControl2 -DX Coil Cap-FF,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,,"From PNNL Prototype Buildings ApartmentMidRise, HotelSmall, OfficeSmall, RetailStandAlone, RetailStripmall, SchoolPrimary, Warehouse" -DX-Bypass-Factor-fAirflow,DXCool/Heat,Quadratic,QRatio,Airflow,,-0.2542341,1.2182557,0.03597841,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -DX-Bypass-Factor-fEWB&EDB,DXCool/Heat,BiQuadratic,QRatio,EWB,EDB,0.8463094,0.014259096,0.000184,-0.014791716,-0.00000548,0.000487,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -DX-Bypass-Factor-fPLR,DXCool/Heat,Linear,QRatio,PLR,,1,0,,,,,,,,,,,,,,,From .dat files included with MASControl2 -DX-Cap-fAirflow,DXCool/Heat,Cubic,QRatio,Airflow,,0.06429396,1.99755645,-1.44277024,0.38091758,,,,,,,,,,,,,From .dat files included with MASControl2 -DX-Cool-Cap-fEWB&OAT,DXCool/Heat,BiQuadratic,QRatio,EWB,OAT,0.86791562,0.014247648,0.000554,-0.007558056,0.000033,-0.000192,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -DX-Cool-Cap-fRPM&OAT,DXCool/Heat,BiQuadratic,QRatio,RPM,OAT,32,9.549296596,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 -DX-Cool-CondFan-fPLR&OAT,DXCool/Heat,BiQuadratic,PwrRatio,PLR,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 -DX-Cool-CycleLoss-fPLR,DXCool/Heat,Linear,QRatio,PLR,,0.7,0.3,,,,,,,,,,,,,,,From .dat files included with MASControl2 -DX-Cool-EIR-fEWB&OAT,DXCool/Heat,BiQuadratic,EIRRatio,EWB,OAT,0.1210048,0.0285336,-0.000411,0.02134944,0.000161,-0.00068,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -DX-Cool-EIR-fPLR,DXCool/Heat,Cubic,EIRRatio,PLR,,0.201,-0.0312,1.95,-1.12,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -DX-Cool-EIR-fRPM&OAT,DXCool/Heat,BiQuadratic,EIRRatio,RPM,OAT,32,9.549296596,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 -DX-Cool-Waste-Heat-fEWB&OAT,DXCool/Heat,BiLinear,QRatio,EWB,OAT,1,0,0,,,,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -DX-Cool-Waste-Heat-fRPM&OAT,DXCool/Heat,BiQuadratic,QRatio,RPM,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 -DX-Heat-Cap-fEDB&OAT,DXCool/Heat,BiQuadratic,QRatio,EDB,OAT,0.7422592,0,0,0.030682602,0.0000323,0,,,,,12.77778,29.44444,-12.22222,29.44444,,,From .dat files included with MASControl2 -DX-Heat-Cap-fRPM&OAT,DXCool/Heat,BiQuadratic,QRatio,RPM,OAT,32,9.549296596,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 -DX-Heat-CondFan-fPLR&OAT,DXCool/Heat,BiQuadratic,PwrRatio,PLR,OAT,1,0,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 -DX-Heat-CycleLoss-fPLR,DXCool/Heat,Linear,QRatio,PLR,,0.75,0.25,,,,,,,,,,,,,,,From .dat files included with MASControl2 -DX-Heat-EIR-fEDB&OAT,DXCool/Heat,BiQuadratic,EIRRatio,EDB,OAT,1.25399584,0,0,-0.040063338,0.0010877,0,,,,,12.77778,29.44444,-12.22222,29.44444,,,From .dat files included with MASControl2 -DX-Heat-EIR-fPLR,DXCool/Heat,Cubic,EIRRatio,PLR,,0.0857,0.939,-0.183,0.159,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -DX-Heat-EIR-fRPM&OAT,DXCool/Heat,BiQuadratic,EIRRatio,RPM,OAT,32,9.549296596,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 -DX-Heat-Waste-Heat-fEDB&OAT,DXCool/Heat,BiLinear,QRatio,EDB,OAT,1,0,0,,,,,,,,12.77778,29.44444,-12.22222,29.44444,,,From .dat files included with MASControl2 -DX-Heat-Waste-Heat-fRPM&OAT,DXCool/Heat,BiQuadratic,QRatio,RPM,OAT,1,0,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 -DX-Sens-Cap-fAirflow,DXCool/Heat,Cubic,QRatio,Airflow,,0.34465606,0.89289891,-0.3554498,0.1178948,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -DX-Sens-Cap-fEWB&OAT,DXCool/Heat,BiQuadratic,QRatio,EWB,OAT,2.93224448,-0.09445968,0.0002,-0.007176816,0.0000103,0.000109,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -DXCOOL-NECB2011-REF-CAPFFLOW,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,1,0,0,,,,,,,,0,1,,,,,From NECB 2011 -DXCOOL-NECB2011-REF-CAPFT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.867905,0.0142459,0.00055436,-0.0075575,0.000033,-0.0001918,,,,,13,24,24,46,,,From NECB 2011 -DXCOOL-NECB2011-REF-COOLEIRFFLOW,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1,0,0,,,,,,,,0,1,,,,,From NECB 2011 -DXCOOL-NECB2011-REF-COOLEIRFT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.116936,0.0284933,-0.0004112,0.0214108,0.00016103,-0.0006791,,,,,13,24,24,46,,,From NECB 2011 -DXCOOL-NECB2011-REF-COOLPLFFPLR,DX Cooling Coil,Cubic,EIRRatio,QRatio,,0.0277,4.9151,-8.184,4.2702,,,,,,,0.7,1,,,,,"From NECB, curve modified to take into account how PLF is used in E+, and PLF ranges (> 0.7)" -DXHEAT-NECB2011-REF-CAPFFLOW,DX Heating Coil,Cubic,QRatio,FlowRatio,,0.84,0.16,0,0,,,,,,,0.5,1.5,,,,,From NECB 2011 -DXHEAT-NECB2011-REF-CAPFT,DX Heating Coil,Cubic,QRatio,Toadb,,0.729,0.0319,0.000136,-0.00000875,,,,,,,-20,20,,,,,From NECB 2011 -DXHEAT-NECB2011-REF-EIRFFLOW,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.3824,-0.4336,0.0512,,,,,,,,0,1,,,,,From NECB 2011 -DXHEAT-NECB2011-REF-EIRFT,DX Heating Coil,Cubic,EIRRatio,Toadb,,1.2183,-0.03612,0.00142,-0.0000268,,,,,,,-20,20,,,,,From NECB 2011 -DXHEAT-NECB2011-REF-PLFFPLR,DX Heating Coil,Cubic,EIRRatio,QRatio,,0.3696,2.3362,-2.9577,1.2596,,,,,,,0.7,1,,,,,From NECB 2011 -Minisplit-Heat-Cap-fT,DX Heating Coil,BiQuadratic,QRatio,Tiadb,Toadb,1.14715889,-0.010386676,0,0.008653846,0,0,,,,,-100,100,-100,100,,,From OpenStudio-HPXML -Minisplit-Heat-Cap-fFF,DX Heating Coil,Quadratic,QRatio,Tiadb,Toadb,1,0,0,,,,,,,,0,2,0,2,,,From OpenStudio-HPXML -Minisplit-Heat-EIR-fT,DX Heating Coil,BiQuadratic,EIRRatio,Tiadb,Toadb,0.99999417,0.004684594,5.90129E-05,-0.002862447,1.30411E-05,-0.000161729,,,,,-100,100,-100,100,,,From OpenStudio-HPXML -Minisplit-Heat-EIR-fFF,DX Heating Coil,Quadratic,EIRRatio,Tiadb,Toadb,1,0,0,,,,,,,,0,2,0,2,,,From OpenStudio-HPXML -Minisplit-Heat-PLF-fPLR,DX Heating Coil,BiQuadratic,EIRRatio,Tiadb,Toadb,0.89,0.11,,,,,,,,,0,1,0.6,1,,,From OpenStudio-HPXML -Minisplit-Cool-Cap-fT,DX Cooling Coil,BiQuadratic,QRatio,Tiadb,Toadb,0.75319835,0.003618194,0,0.006574385,-6.87181E-05,0,,,,,0,100,0,100,,,From OpenStudio-HPXML -Minisplit-Cool-Cap-fFF,DX Cooling Coil,Quadratic,QRatio,Tiadb,Toadb,1,0,0,,,,,,,,0,2,0,2,,,From OpenStudio-HPXML -Minisplit-Cool-EIR-fT,DX Cooling Coil,BiQuadratic,EIRRatio,Tiadb,Toadb,-0.063769248,-0.001336059,1.41306E-05,0.019433076,-4.91396E-05,-4.90934E-05,,,,,0,100,0,100,,,From OpenStudio-HPXML -Minisplit-Cool-EIR-fFF,DX Cooling Coil,Quadratic,EIRRatio,Tiadb,Toadb,1,0,0,,,,,,,,0,2,0,2,,,From OpenStudio-HPXML -Minisplit-Cool-PLF-fPLR,DX Cooling Coil,BiQuadratic,EIRRatio,Tiadb,Toadb,0.89,0.11,,,,,,,,,0,1,0.6,1,,,From OpenStudio-HPXML -EFG-Si_Spectral-fAirMass,PV-Module,Cubic,,AirMass,,0.93235892,0.05557786,-0.00723784,0.00016577,,,,,,,,,,,,,From .dat files included with MASControl2 -Elec-HW-Blr-EIR-fPLR,ElecBoilers,Linear,EIRRatio,PLR,,0.02,0.98,,,,,,,,,,,,,,,From .dat files included with MASControl2 -Elec-Stm-Blr-EIR-fPLR,ElecBoilers,Linear,EIRRatio,PLR,,0.03,0.97,,,,,,,,,,,,,,,From .dat files included with MASControl2 -Engine-Chlr-Cap-fCHWT&ECT,EngineChiller,BiQuadratic,QRatio,CHWT,ECT,1.02245976,0.033624396,0,-0.00837585,0,0,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Engine-Chlr-HeatRej-fECT,EngineChiller,Cubic,,ECT,,0.81658293,0.00622926,0,0,,,,,,,60,150,,,,,From .dat files included with MASControl2 -Engine-Chlr-HeatRej-fPLR,EngineChiller,Cubic,,PLR,,1.05269921,-0.05269912,0,0,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Engine-Chlr-HIR-fCHWT&ECT,EngineChiller,BiQuadratic,,CHWT,ECT,0.76855672,-0.016619742,0.001163452,0.007451082,0.000302,-0.000971,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Engine-Chlr-HIR-fPLR,EngineChiller,Quadratic,,PLR,,0.12571636,0.34714213,0.52714163,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Engine-Exh-fPLR,EngineGenerator,Quadratic,,PLR,,0.024516,0.3323871,0.6430968,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Engine-HIR-fPLR,EngineGenerator,Linear,,PLR,,0.107,0.893,,,,,,,,,,,,,,,From .dat files included with MASControl2 -Engine-Jac-fPLR,EngineGenerator,Quadratic,,PLR,,0.287936,1.0204516,-0.3083871,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -FluidCooler-FluidCap-fApp&WB,FluidCooler,BiQuadratic,QRatio,App,WB,-0.16463568,0.048677022,-0.001437296,0.072275256,0.000924,0.005085439,,,,,,,,,,,From .dat files included with MASControl2 -FluidCooler-FluidCap-fRng&WB,FluidCooler,BiQuadratic,QRatio,Rng,WB,0,0.18,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 -ForcedDraft-Blr-HIR-fPLR,FuelBoilers,Quadratic,,PLR,,0.01599992,0.94495332,0.03904687,,,,,,,,,,,,,,From .dat files included with MASControl2 -ForCurve w Dischrg Dampers FPLR,FanEIR-FPLR,Quadratic,,PLR,,0.190667,0.31,0.5,,,,,,,,,,,,0.22,1,From .dat files included with MASControl2 -ForCurve w Inlet Vanes FPLR,FanEIR-FPLR,Quadratic,,PLR,,0.339619,-0.848139,1.495671,,,,,,,,,,,,0.22,1,From .dat files included with MASControl2 -FURNACE_PACU_VAV_CoolCCarrier48TM014_12tons_EIRFFF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.19525,-0.306138,0.110973,,,,,,,,0.75,1.25,,,,,From PNNL OfficeMedium -FURNACE_PACU_VAV_CoolCCarrier48TM014_12tons_EIRFT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,-0.536161,0.105138,-0.00172659,0.0149848,0.000659948,-0.0017385,,,,,16.5556,22.1111,23.7778,47.66,,,From PNNL Prototype Buildings OfficeMedium -FURNACE-EFFPLR-NECB2011,Gas Heating Coil,Cubic,FIRRatio,QRatio,,0.7277,1.0667,-1.5174,0.7282,,,,,,,0,1,,,,,From NECB 2011 -Furnace-HIR-fPLR,Furnace,Quadratic,FIRRatio,PLR,,0.0186,1.09,-0.113,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Gas-Absor-Cap-fCHWT&ECT,Chiller/Heater,BiQuadratic,QRatio,CHWT,ECT,0.362073,0.0001386,0.001458,0.0733878,-0.00206064,0.00101,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Gas-Absor-HCap-fCoolPLR,Chiller/Heater,Quadratic,QRatio,CoolPLR,,0.863599,-1.30495346,0.44135284,,,,,,,,,,,,,,From .dat files included with MASControl2 -Gas-Absor-HIR-fCHWT&ECT,Chiller/Heater,BiQuadratic,,CHWT,ECT,0.96182051,-0.0507105,0.003155468,0.005732838,0.000349,-0.00118516,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Gas-Absor-HIR-fDesiccantT,Chiller/Heater,Cubic,,DesiccantT,,0.85427336,0.002997504,0.0000426,0,,,,,,,100,300,,,,,From .dat files included with MASControl2 -Gas-Absor-Qreg-fDesiccantT,Chiller/Heater,Cubic,,DesiccantT,,0.5984,-0.00234,0,0,,,,,,,100,300,,,,,From .dat files included with MASControl2 -GasTurbine-Cap-fPLR,GasTurbineGen,Linear,QRatio,PLR,,1.24,-0.0041,,,,,,,,,,,,,,,From .dat files included with MASControl2 -GasTurbine-Exh-fPLR,GasTurbineGen,Quadratic,,PLR,,0.295626,0.4930194,0.2113548,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -GasTurbine-HIR-fPLR,GasTurbineGen,Quadratic,,PLR,,0.442979,0.3974,0.1569621,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -GHP-Bypass-Factor-fAirflow,GasHeat-Pump,Quadratic,QRatio,Airflow,,-0.254,1.22,0.036,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -GHP-Bypass-Factor-fEWB&EDB,GasHeat-Pump,BiQuadratic,QRatio,EWB,EDB,0.85028352,0.014256792,0.000184,-0.014791716,-0.00000548,0.000487,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -GHP-Bypass-Factor-fPLR,GasHeat-Pump,Linear,QRatio,PLR,,1,0,,,,,,,,,,,,,,,From .dat files included with MASControl2 -GHP-Cool-Cap-fEWB&OAT,GasHeat-Pump,BiLinear,QRatio,EWB,OAT,1.1688,0.01926,-0.01539,,,,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -GHP-Cool-Cap-fRPM&OAT,GasHeat-Pump,BiQuadratic,QRatio,RPM,OAT,-372.736,-234.129654,-36.65800433,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 -GHP-Cool-CondFan-fPLR&OAT,GasHeat-Pump,BiQuadratic,,PLR,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 -GHP-Cool-CycleLoss-fPLR,GasHeat-Pump,Linear,QRatio,PLR,,0.82,0.18,,,,,,,,,,,,,,,From .dat files included with MASControl2 -GHP-Cool-HIR-fEWB&OAT,GasHeat-Pump,BiQuadratic,,EWB,OAT,1.1386752,-0.049248,0.000914,0.02128896,0.000306,-0.000953,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -GHP-Cool-HIR-fRPM&OAT,GasHeat-Pump,BiQuadratic,,RPM,OAT,-369.60598,-234.0532596,-36.93157152,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 -GHP-Cool-Waste-Heat-fEWB&OAT,GasHeat-Pump,BiLinear,QRatio,EWB,OAT,1,0,0,,,,,,,,,,,,,,From .dat files included with MASControl2 -GHP-Cool-Waste-Heat-fRPM&OAT,GasHeat-Pump,BiQuadratic,QRatio,RPM,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 -GHP-Defrost-Frac-fOWB&ODB,GasHeat-Pump,BiLinear,QRatio,OWB,ODB,0.0333,0,0,,,,,,,,-23.33333,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 -GHP-Heat-Cap-fEDB&OAT,GasHeat-Pump,BiQuadratic,QRatio,EDB,OAT,0.8291632,0,0,0.01817136,0.000281,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 -GHP-Heat-Cap-fRPM&OAT,GasHeat-Pump,BiQuadratic,QRatio,RPM,OAT,157.86,89.17133162,12.58409104,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 -GHP-Heat-CondFan-fPLR&OAT,GasHeat-Pump,BiQuadratic,,PLR,OAT,1,0,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 -GHP-Heat-CycleLoss-fPLR,GasHeat-Pump,Linear,QRatio,PLR,,0.82,0.18,,,,,,,,,,,,,,,From .dat files included with MASControl2 -GHP-Heat-HIR-fEDB&OAT,GasHeat-Pump,BiQuadratic,,EDB,OAT,1.14897728,0,0,-0.017395056,-0.000026,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 -GHP-Heat-HIR-fRPM&OAT,GasHeat-Pump,BiQuadratic,,RPM,OAT,194.037,109.788263,15.50214113,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 -GHP-Heat-Waste-Heat-fEDB&OAT,GasHeat-Pump,BiLinear,QRatio,EDB,OAT,1,0,0,,,,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 -GHP-Heat-Waste-Heat-fRPM&OAT,GasHeat-Pump,BiQuadratic,QRatio,RPM,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 -GHP-Sens-Cap-fEWB&OAT,GasHeat-Pump,BiQuadratic,QRatio,EWB,OAT,1.49637568,0.079056576,-0.004212,-0.030189312,0.000157,0.00062,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -Glass Door Defrost Curve,Refrigerated Case,Cubic,,,,0.3475,0.0296,0.0007,0.00003,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings -Glass Door Latent Curve,Refrigerated Case,Cubic,,,,0.3379,0.0309,0.0005,0.00004,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings -GoodCyclingAC-EIR-fPLR,CyclingAC,Cubic,EIRRatio,PLR,,0.00000273,1.05259,-0.0552087,0.00262236,,,,,,,,,,,,,From .dat files included with MASControl2 -GSHP/WLHP_BF_fAirflow-Old,GSHP/WLHPCurves,Cubic,QRatio,Airflow,,-0.828,14.3,-21.9,9.4,,,,,,,,,,,,,From .dat files included with MASControl2 -GSHP/WLHP_BF_fEwbEwt,GSHP/WLHPCurves,BiLinear,QRatio,EWB,EWT,-0.2016,0.0297,0.02646,,,,,,,,,,,,0.347365,1.67341,From .dat files included with MASControl2 -GSHP/WLHP_BF_fEwbEwt-Old,GSHP/WLHPCurves,BiQuadratic,QRatio,EWB,EWT,-5.522656,0.735768,-0.0185004,0.1418832,0.000943,-0.010206,,,,,,,,,,,From .dat files included with MASControl2 -GSHP/WLHP_Cool_Cap_fEwbEwt,GSHP/WLHPCurves,BiLinear,QRatio,EWB,EWT,0.88114368,0.015264,-0.007493418,,,,,,,,,,,,0.803411,1.18555,From .dat files included with MASControl2 -GSHP/WLHP_Cool_EIR_fEwbEwt,GSHP/WLHPCurves,BiLinear,EIRRatio,EWB,EWT,0.4111216,-0.00396,0.03011184,,,,,,,,,,,,0.300674,1.80627,From .dat files included with MASControl2 -GSHP/WLHP_H/C_EIR-fPLR,GSHP/WLHPCurves,Quadratic,EIRRatio,PLR,,0.0414,0.328,0.575337,,,,,,,,,,,,0,1,From .dat files included with MASControl2 -GSHP/WLHP_H/C_EIR-fPLR-Old,GSHP/WLHPCurves,Cubic,EIRRatio,PLR,,0.00988,1.08,-0.105,0.0151,,,,,,,,,,,,,From .dat files included with MASControl2 -GSHP/WLHP_Heat_Cap_fEdbEwt,GSHP/WLHPCurves,BiLinear,QRatio,EDB,EWT,1.07264,-0.003564,0.027,,,,,,,,,,,,0.966284,1.86368,From .dat files included with MASControl2 -GSHP/WLHP_Heat_EIR_fEdbEwt,GSHP/WLHPCurves,BiLinear,EIRRatio,EDB,EWT,0.59444,0.01908,-0.009774,,,,,,,,,,,,0.681922,1.10294,From .dat files included with MASControl2 -HeatSys1 Boiler Non-Condensing Boiler Curve,Boiler,Cubic,FIRRatio,QRatio,,0.626428326,0.645643582,-0.77720685,0.313806701,,,,,,,0.1,1,,,,,From Prototype Buildings -HeatWheel-EIR-fSpeed,ERVUnit,Linear,EIRRatio,Speed,,25.8,7.639437277,,,,,,,,,,,,,,,From .dat files included with MASControl2 -Herm-Cent-Cap-fCHWT&ECT,HermCentrifugal,BiQuadratic,QRatio,CHWT,ECT,0.257896,0.0389016,-0.000217,0.0468684,-0.000943,-0.000343,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Herm-Cent-EIR-fCHWT&ECT,HermCentrifugal,BiQuadratic,EIRRatio,CHWT,ECT,0.933884,-0.058212,0.00450036,0.00243,0.000486,-0.001215,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Herm-Cent-EIR-fPLR,HermCentrifugal,Quadratic,EIRRatio,PLR,,0.222903,0.313387,0.46371,,,,,,,,0,0.105,,,,,From .dat files included with MASControl2 -Herm-Rec-Cap-fCHWT&ECT,HermReciprocatg,BiQuadratic,QRatio,CHWT,ECT,0.507883,0.1452276,-0.00625644,-0.0011178,-0.00013,-0.000282,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Herm-Rec-EIR-fCHWT&ECT,HermReciprocatg,BiQuadratic,EIRRatio,CHWT,ECT,1.030757,-0.103536,0.00710208,0.0093186,0.000318,-0.00104,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Herm-Rec-EIR-fPLR,HermReciprocatg,Quadratic,EIRRatio,PLR,,0.088065,1.137742,-0.225806,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Hospital Kitchen_Flr_5_Case:1_WALKINFREEZERSingleShelfHorizontal_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.0236,0.0006,0,0,,,,,,,-35,20,,,,,From Prototype Buildings -Hospital Kitchen_Flr_5_Case:2_SELFCONTAINEDDISPLAYCASEMultiShelfVertical_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,6.02558E-05,1.23732E-06,,,,,,,-35,20,,,,,From Prototype Buildings -HotelLarge Kitchen_Flr_6_Case:1_WALKINFREEZERSingleShelfHorizontal_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.0236,0.0006,0,0,,,,,,,-35,20,,,,,From Prototype Buildings -HotelLarge Kitchen_Flr_6_Case:2_SELFCONTAINEDDISPLAYCASEMultiShelfVertical_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,6.02558E-05,1.23732E-06,,,,,,,-35,20,,,,,From Prototype Buildings -HP-Bypass-Factor-fAirflow,Water-LoopHP,Cubic,QRatio,Airflow,,-0.828,14.3,-21.9,9.4,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -HP-Bypass-Factor-fEWB&EWT,Water-LoopHP,BiQuadratic,QRatio,EWB,EWT,-5.522656,0.735768,-0.0185004,0.1418832,0.000943,-0.010206,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -HP-Cool-Cap-fEWB&EWT,Water-LoopHP,BiQuadratic,QRatio,EWB,EWT,0.38053696,0.041974272,-0.0000309,-0.006642864,0.0000228,-0.0000881,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -HP-Cool-EIR-fEWB&EWT,Water-LoopHP,BiQuadratic,EIRRatio,EWB,EWT,1.3257696,-0.0504504,0.000988,0.02036448,0.0000791,-0.000531,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -HP-Cool-EIR-fPLR,Water-LoopHP,Linear,EIRRatio,PLR,,0.125,0.875,,,,,,,,,,,,,,,From .dat files included with MASControl2 -HP-Heat-Cap-fEDB&EWT,Water-LoopHP,BiLinear,QRatio,EDB,EWT,0.72324,-0.012204,0.02538,,,,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -HP-Heat-EIR-fEDB&EWT,Water-LoopHP,BiLinear,EIRRatio,EDB,EWT,1.2124,0.01089,-0.02088,,,,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -HP-Heat-EIR-fPLR,Water-LoopHP,Cubic,EIRRatio,PLR,,0.0857,0.939,-0.183,0.15897022,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -HP-Sens-Cap-fAirflow,Water-LoopHP,Cubic,QRatio,Airflow,,-0.13,2.16,-1.6,0.573,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -HP-Sens-Cap-fEWB&EWT,Water-LoopHP,BiQuadratic,QRatio,EWB,EWT,1.68318464,0.012410496,-0.00215784,-0.009251064,0.0000632,0.000174,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -HPACCoolCapFFF,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,, -HPACCoolCapFT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.766956,0.0107756,-4.14703E-05,0.00134961,-0.000261144,0.000457488,,,,,12.77778,23.88889,21.11111,46.11111,,, -HPACCOOLEIRFFF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.156,-0.1816,0.0256,,,,,,,,0.5,1.5,,,,, -HPACCOOLEIRFT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.297145,0.0430933,-0.000748766,0.00597727,0.000482112,-0.000956448,,,,,12.77778,23.88889,21.11111,46.11111,,, -HPACCOOLPLFFPLR,DX Cooling Coil,Quadratic,EIRRatio,QRatio,,0.85,0.15,0,,,,,,,,0,1,,,,, -HPACHeatCapFFF,DX Heating Coil,Cubic,QRatio,FlowRatio,,0.84,0.16,0,0,,,,,,,0.5,1.5,,,,,From Prototype Buildings -HPACHeatCapFT,DX Heating Coil,Cubic,QRatio,Toadb,,0.758746,0.027626,0.000148716,3.4992E-06,,,,,,,-20,20,,,,,From Prototype Buildings -HPACHeatEIRFFF,DX Heating Coil,Quadratic,EIRRatio,FlowRatio,,1.3824,-0.4336,0.0512,,,,,,,,0,1,,,,,From Prototype Buildings -HPACHeatEIRFT,DX Heating Coil,Cubic,EIRRatio,Toadb,,1.19248,-0.0300438,0.00103745,-0.000023328,,,,,,,-20,20,,,,,From Prototype Buildings -Htrec-Chlr-Cap-fCHWT&ECT,ElecHeatRecover,BiQuadratic,QRatio,CHWT,ECT,0.257896,0.0389016,-0.000217,0.0468684,-0.000943,-0.000343,,,,,4.44444,18.33333,12.77778,51.66667,,,From .dat files included with MASControl2 -Htrec-Chlr-EIR-fCHWT&ECT,ElecHeatRecover,BiQuadratic,EIRRatio,CHWT,ECT,0.933884,-0.058212,0.00450036,0.00243,0.000486,-0.001215,,,,,4.44444,18.33333,12.77778,51.66667,,,From .dat files included with MASControl2 -Htrec-Chlr-EIR-fPLR,ElecHeatRecover,Quadratic,EIRRatio,PLR,,0.349032,0.263871,0.387097,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Htrej-Fan-Pwr-fDamper,FluidCooler,Cubic,,Damper,,0.37607971,-0.21440694,1.00540793,-0.16712119,,,,,,,,,,,0.36,1,From .dat files included with MASControl2 -HW-Coil-Cap-fAirflow,HWCoils,Quadratic,QRatio,Airflow,,0.289,1.03,-0.317,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -HW-Coil-Cap-fdT,HWCoils,Quadratic,QRatio,dT,,-0.00467,1.8,0.010960272,,,,,,,,0,150,,,0.01,,From .dat files included with MASControl2 -HW-Coil-Cap-fFluidFlow,HWCoils,Quadratic,QRatio,FluidFlow,,0.18,2945.2432,-2540000,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Indirect-Effectiveness-fFlow,EvapCooler,Quadratic,,Flow,,1.1,-350,306000,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Inverter_EIR-fPLR,PV-Inverter,Quadratic,EIRRatio,PLR,,0.01677774,1.03766656,-0.05444431,,,,,,,,,,,,,,From .dat files included with MASControl2 -Large-CHW-Bypass-fAirflow,CHWCoils,Quadratic,QRatio,Airflow,,0.397,0.15,0.45374713,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Large-CHW-Coil-Bypass-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,0.435936,0.23652,-0.0047628,-0.1330272,0.00119556,0.000859,,,,,15.55556,29.44444,12.77778,29.44444,,,From .dat files included with MASControl2 -Large-CHW-Coil-Cap-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,0.09793216,-0.13886496,0.0124416,0.088907328,0.001938946,-0.009305604,,,,,15.55556,29.44444,12.77778,29.44444,,,From .dat files included with MASControl2 -Large-CHW-Sens-Cap-fAirflow,CHWCoils,Quadratic,QRatio,Airflow,,0.202,0.855,-0.057,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Large-CHW-Sens-Cap-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,0.12076864,-0.124558848,0.0063828,0.11146032,0.001847902,-0.006508285,,,,,15.55556,13.33333,12.77778,29.44444,,,From .dat files included with MASControl2 -Lp2Lp_Cap_fCHW&HWR,Loop2Loop,BiQuadratic,QRatio,CHWT,HWR,0.95122179,0.035393436,0.00027,-0.002654118,-0.0000869,-0.000274,,,,,,,,,,,From .dat files included with MASControl2 -Lp2Lp_EIR_fCHW&HWR,Loop2Loop,BiQuadratic,EIRRatio,CHWT,HWR,0.59918703,-0.00950724,0.000335,0.00863883,0.000312,-0.000386,,,,,,,,,,,From .dat files included with MASControl2 -Lp2Lp-EIR-fPLR-1Comp/Ckt,Loop2Loop,Quadratic,EIRRatio,PLR,,0.03481113,0.95945376,0.00573495,,,,,,,,,,,,,,From .dat files included with MASControl2 -Lp2Lp-EIR-fPLR-2Comp/Ckt,Loop2Loop,Quadratic,EIRRatio,PLR,,0.02297712,0.90150452,0.07551826,,,,,,,,,,,,,,From .dat files included with MASControl2 -LT_compressor_capacity,Refrigeration,BiCubic,Capacity,Suction T,Discharge T,170751.834,6102.9037,78.2619862,-2959.4326,19.7876589,-90.958101,0.43596477,-0.0411577,-0.608846,0.459133262,-40,17.8,4.4,54.4,,,From AEDG -LT_compressor_power,Refrigeration,BiCubic,Power,Suction T,Discharge T,29669.2711,1027.63205,18.1066262,-442.19971,11.1335288,-20.380452,0.13998065,-0.0588669,-0.2184515,0.203858467,-40,-17.8,4.4,54.4,,,From AEDG -mc-Si_Spectral-fAirMass,PV-Module,Cubic,,AirMass,,0.96113414,0.02820018,-0.00134585,-0.00012036,,,,,,,,,,,,,From .dat files included with MASControl2 -Measured_CoolCStandard10Ton_EIRFFF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.192,-0.1917,0,,,,,,,,0.776,1.197,,,,,From PNNL Prototype FullServiceRestaurant -MNECB-CAP-FAPP&WB,CAP-FAPP&WB,BiQuadratic,QRatio,App,WB,-0.05425558,-0.063981648,0.026052289,0.260016714,0.000809093,0.015903767,,,,,,,,,,,From .dat files included with MASControl2 -MNECB-CAP-FRNG&WB,CAP-FRNG&WB,BiQuadratic,QRatio,Rng,WB,188.8588489,0.300231774,-0.045692003,35.40844622,0.601350934,0.78576062,,,,,,,,,,,From .dat files included with MASControl2 -MNECB-Centrif-CAP-FT,Centrif-CAP-FT,BiQuadratic,QRatio,T,T,0.70790824,-0.002006568,-0.00259605,0.030058776,-0.001056434,0.002045704,,,,,,,,,,,From .dat files included with MASControl2 -MNECB-Centrif-EIR-FPLR,Centrif-EIR-FPLR,Quadratic,EIRRatio,PLR,,0.17149273,0.58820208,0.23737257,,,,,,,,,,,,,,From .dat files included with MASControl2 -MNECB-Centrif-EIR-FT,Centrif-EIR-FT,BiQuadratic,EIRRatio,T,T,0.5605438,-0.01377927,0.0000657,0.013219362,0.000268596,-0.000501131,,,,,,,,,,,From .dat files included with MASControl2 -MNECB-DW-HIR-fPLR,DHW-HIR,Quadratic,,PLR,,0.021826,0.97763,0.000543,,,,,,,,,,,,,,From .dat files included with MASControl2 -MNECB-HW-HIR-fPLR,HW-HIR,Quadratic,,PLR,,0.082597,0.996764,-0.079361,,,,,,,,,,,,,,From .dat files included with MASControl2 -MNECB-Recip-CAP-FT,Recip-CAP-FT,BiQuadratic,QRatio,T,T,1.0303123,0.033469794,0.00023639,-0.007295868,-0.0000232,-0.000148943,,,,,,,,,,,From .dat files included with MASControl2 -MNECB-Recip-EIR-FPLR,Recip-EIR-FPLR,Quadratic,EIRRatio,PLR,,0.08144133,0.41927141,0.49939604,,,,,,,,,,,,,,From .dat files included with MASControl2 -MNECB-Recip-EIR-FT,Recip-EIR-FT,BiQuadratic,EIRRatio,T,T,0.49969897,-0.013084056,0.000266425,0.016592526,0.000185393,-0.000375646,,,,,,,,,,,From .dat files included with MASControl2 -Multi Shelf Vertical Latent Energy Multiplier,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,-6.02558E-05,1.23732E-06,,,,,,,-35,20,,,,,From Reference Buildings -Multi Zone VAV with Airfoil or Backward Incline riding the curve,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.1631,1.5901,-0.8817,0.1281,,,,,,,0,1,,,0.7,,From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method -Multi Zone VAV with Airfoil or Backward Incline with inlet vanes,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.9977,-0.659,0.9547,-0.2936,,,,,,,0,1,,,0.5,,From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method -Multi Zone VAV with Forward Curved fans riding the curve,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.1224,0.612,0.5983,-0.3334,,,,,,,0,1,,,0.3,,From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method -Multi Zone VAV with Forward Curved with inlet vanes,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.3038,-0.7608,2.2729,-0.8169,,,,,,,0,1,,,0.3,,From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method -Multi zone VAV with static pressure reset,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.040759894,0.08804497,-0.07292612,0.943739823,,,,,,,0,1,,,0.1,,"OpenStudio default, baseline for System Types 5-8 from ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method" -Multi Zone VAV with vane-axial with variable pitch blades,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.1639,-0.4016,1.9909,-0.7541,,,,,,,0,1,,,0.2,,From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method -Multi Zone VAV with VSD and fixed SP setpoint,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.0013,0.147,0.9506,-0.0998,,,,,,,0,1,,,0.2,,Appendix G baseline from ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method -New_Low_Temp_Comp_Cap_Curve,,BiCubic,,,,58336.861,1561.7435,6.6068129,-283.65007,-0.12023494,-12.495749,-0.11627856,0.002277001,-0.11814833,0.032839613,-40,-17.8,4.4,54.4,,, -New_Low_Temp_Comp_Pwr_Curve,,BiCubic,,,,6274.9904,61.390661,1.6208537,129.11279,0.87411617,1.9581173,0.030293311,0.005754678,0.004653957,-0.000749905,-40,-17.8,4.4,54.4,,, -New_Med_Temp_Comp_Cap_Curve,,BiCubic,,,,61412.175,1570.8519,13.533449,-500.19524,8.1639124,-3.6895385,0.054485574,-0.088096805,0.006381584,-0.037503058,-23.3,7.2,10,60,,, -New_Med_Temp_Comp_Pwr_Curve,,BiCubic,,,,4994.0336,170.24972,2.8463891,356.79403,-6.3074704,-1.409856,0.012160476,0.076231729,-0.057527471,0.009054446,-23.3,7.2,10,60,,, -No SP Reset VSD Fan,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.070428852,0.385330201,-0.460864118,1.00920344,,,,,,,0,1,,,0.1,,"From California Energy Commision, ""Advanced Variable Air Volume System Design Guide,"" October 2004" -Old_Low_Temp_Comp_Cap_Curve,,BiCubic,,,,170751.834,6102.9037,78.2619862,-2959.43265,19.7876589,-90.9581015,0.435964768,-0.041157653,-0.60884596,0.459133262,-40,-17.8,4.4,54.4,,, -Old_Low_Temp_Comp_Pwr_Curve,,BiCubic,,,,29669.2711,1027.63205,18.1066262,-442.199714,11.1335288,-20.3804519,0.139980653,-0.058866918,-0.218451538,0.203858467,-40,-17.8,4.4,54.4,,, -Old_Med_Temp_Comp_Cap_Curve,,BiCubic,,,,151166.436,5266.34789,60.6727151,-1851.55938,5.73132755,-46.9277173,0.136401203,-0.035697884,-0.403053994,-0.039290478,-23.3,7.2,10,60,,, -Old_Med_Temp_Comp_Pwr_Curve,,BiCubic,,,,7438.92229,-269.597565,-9.85610446,553.57326,-3.38588961,14.8657878,-0.100796292,0.009822793,0.097362356,-0.039675217,-23.3,7.2,10,60,,, -Open Latent Curve,Refrigerated Case,Cubic,,,,-0.0187,0.0458,0.0011,0.00005,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings -Open-Cent-Cap-fCHWT&ECT,OpenCentrifugal,BiQuadratic,QRatio,CHWT,ECT,0.257896,0.0389016,-0.000217,0.0468684,-0.000943,-0.000343,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Open-Cent-EIR-fCHWT&ECT,OpenCentrifugal,BiQuadratic,EIRRatio,CHWT,ECT,0.933884,-0.058212,0.00450036,0.00243,0.000486,-0.001215,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Open-Cent-EIR-fPLR,OpenCentrifugal,Quadratic,EIRRatio,PLR,,0.222903,0.313387,0.46371,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Open-Rec-Cap-fCHWT&ECT,OpenReciprocatg,BiQuadratic,QRatio,CHWT,ECT,0.507883,0.1452276,-0.00625644,-0.0011178,-0.00013,-0.000282,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Open-Rec-EIR-fCHWT&ECT,OpenReciprocatg,BiQuadratic,EIRRatio,CHWT,ECT,1.030757,-0.103536,0.00710208,0.0093186,0.000318,-0.00104,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Open-Rec-EIR-fPLR,OpenReciprocatg,Quadratic,EIRRatio,PLR,,0.088065,1.137742,-0.225806,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -OpenTwr-FluidCap-fApp&WB,OpenTower,BiQuadratic,QRatio,App,WB,0.11735985,0.010588518,0.000701,0.052439526,0.000724,0.003437899,,,,,,,,,,,From .dat files included with MASControl2 -OpenTwr-FluidCap-fRng&WB,OpenTower,BiQuadratic,QRatio,Rng,WB,0.11661702,0.202450932,-0.004401443,-0.01592307,0.000101,-0.001101632,,,,,,,,,,,From .dat files included with MASControl2 -PoorCyclingAC-EIR-fPLR,CyclingAC,Cubic,EIRRatio,PLR,,0.000362523,1.32573,-0.407603,0.0818194,,,,,,,,,,,,,From .dat files included with MASControl2 -PSZ-AC DX Coil EIR-FT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.342414409,0.034885008,-0.0006237,0.004977216,0.000437951,-0.000728028,,,,,12.77778,23.88889,23.88889,46.11111,,,"From PNNL Prototype Buildings HotelSmall, Warehouse" -PSZ-AC DX Unitary Package EIRFT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.297145,0.0430933,-0.000748766,0.00597727,0.000482112,-0.000956448,,,,,12.77778,23.88889,21.11111,46.11111,,,"From PNNL Prototype Buildings RetailStandAlone, RetailStripMall,SchoolPrimary" -PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.42415,0.04426,-0.00042,0.00333,-0.00008,-0.00021,,,,,17,22,29,46,,,"From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" -PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR,DX Cooling Coil,Quadratic,EIRRatio,QRatio,,0.771,0.229,0,,,,,,,,0,1,,,,,"From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" -PSZ-AC_CoolCStandard10Ton_EIRFT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,1.23649,-0.02431,0.00057,-0.01434,0.00063,-0.00038,,,,,17,22,29,46,,,"From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" -PSZ-AC_Unitary_PackagecoolCapFT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.766956,0.0107756,-4.14703E-05,0.00134961,-0.000261144,0.000457488,,,,,12.77778,23.88889,21.11111,46.11111,,,"From PNNL Prototype Buildings RetailStandalone, RetailStripMall, SchoolPrimary" -PSZ-AC_Unitary_PackagecoolEIRFFF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.156,-0.1816,0.0256,,,,,,,,0.5,1.5,,,,, -PSZ-AC_Unitary_PackagecoolFFF,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,, -PSZ-AC_Unitary_PackagecoolPLR,DX Cooling Coil,Quadratic,EIRRatio,QRatio,,0.75,0.25,0,,,,,,,,0,1,,,,,"From PNNL Prototype Buildings RetailStandAlone, RetailStripMall, SchoolPrimary" -PSZ-AC:1_Unitary_PackagecoolEIRFFF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.156,-0.1816,0.0256,,,,,,,,0.5,1.5,,,,,"From PNNL Prototype Buildings RetailStandAlone, RetailStripMall, SchoolPrimary" -PSZ-Fine Storage DX Coil Cap-FT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.942587793,0.009543347,0.00068377,-0.011042676,0.000005249,-0.00000972,,,,,12.77778,23.88889,23.88889,46.11111,,,"From PNNL Prototype Buildings HotelSmall, Warehouse" -PSZ-Fine Storage Heating Coil PLF-FPLR,DX Heating Coil,Cubic,EIRRatio,QRatio,,0.8,0.2,0,0,,,,,,,0,1,,,,,From Prototype Buildings -PSZ-Office Heating Coil PLF-FPLR,DX Heating Coil,Cubic,EIRRatio,QRatio,,0.8,0.2,0,0,,,,,,,0,1,,,,,From Prototype Buildings -PSZ135to240_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 -PSZ135to240_BF_fT,BF_fT,BiQuadratic,,T,T,43.269632,-4.898304,0.148392,0.0947376,0.00213192,-0.0134136,,,,,,,,,0,4.04,From .dat files included with MASControl2 -PSZ135to240_CEIR_fPLR,CEIR_fPLR,Cubic,EIRRatio,PLR,,0.0184,1.15,-0.208,0.0423,,,,,,,,,,,,,From .dat files included with MASControl2 -PSZ135to240_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.62774528,-0.060192,0.00260172,-0.005653656,0.0000266,-0.00040824,,,,,,,,,,,From .dat files included with MASControl2 -PSZ135to240_CLoss_fPLR,CLoss_fPLR,Cubic,,PLR,,0.852,0.203,-0.0423,0.00938,,,,,,,,,,,0.8024,1.0728,From .dat files included with MASControl2 -PSZ135to240_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,0.4018688,0.1920384,-0.0077436,-0.01956816,-0.0000415,0.00077436,,,,,,,,,,,From .dat files included with MASControl2 -PSZ135to240_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,-0.0449056,0.07059456,-0.00216432,0.00440856,0.00041148,-0.000245916,,,,,,,,,,,From .dat files included with MASControl2 -PSZ135to240_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 -PSZ135to240_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 -PSZ240to760_BF_fFlow,BF_fFlow,Linear,QRatio,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 -PSZ240to760_BF_fT,BF_fT,BiQuadratic,,T,T,15.8724544,-1.6604928,0.041148,0.03013992,0.000278964,0.00047628,,,,,,,,,0,3.252,From .dat files included with MASControl2 -PSZ240to760_CEIR_fPLR,CEIR_fPLR,Cubic,EIRRatio,PLR,,2.63,-9.5,14.3,-6.4,,,,,,,,,,,,,From .dat files included with MASControl2 -PSZ240to760_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.27910208,-0.0291096,0.00167184,-0.002266416,-0.000031,-0.00033372,,,,,,,,,,,From .dat files included with MASControl2 -PSZ240to760_CLoss_fPLR,CLoss_fPLR,Cubic,,PLR,,0.964,0.289,0.183,-0.131,,,,,,,,,,,0.96,1.3,From .dat files included with MASControl2 -PSZ240to760_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.64083712,-0.06152112,-0.0004698,-0.010834704,-0.0000289,0.000222912,,,,,,,,,,,From .dat files included with MASControl2 -PSZ240to760_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.336608,0.0487944,-0.00116316,-0.005994,0.00067716,-0.00069012,,,,,,,,,,,From .dat files included with MASControl2 -PSZ240to760_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 -PSZ240to760_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 -PSZ65to135_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 -PSZ65to135_BF_fT,BF_fT,BiQuadratic,,T,T,14.931264,-1.5724512,0.04698,0.0015984,0.00096552,-0.00319788,,,,,,,,,0,3.509,From .dat files included with MASControl2 -PSZ65to135_CEIR_fPLR,CEIR_fPLR,Cubic,EIRRatio,PLR,,0.0184,1.15,-0.208,0.0423,,,,,,,,,,,,,From .dat files included with MASControl2 -PSZ65to135_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.2518496,-0.02766672,0.00115344,0.0035388,-0.000134136,-0.000167508,,,,,,,,,,,From .dat files included with MASControl2 -PSZ65to135_CLoss_fPLR,CLoss_fPLR,Cubic,,PLR,,0.882,0.211,-0.0439,0.0098,,,,,,,,,,,0.8323,1.1087,From .dat files included with MASControl2 -PSZ65to135_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.7733472,0.0383688,-0.0038556,-0.01090224,-0.000138348,0.00070632,,,,,,,,,,,From .dat files included with MASControl2 -PSZ65to135_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.5431072,0.03102048,-0.00090072,-0.01496592,0.0006966,-0.000199908,,,,,,,,,,,From .dat files included with MASControl2 -PSZ65to135_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 -PSZ65to135_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 -PTAC_EIR_fPLR,PkgdTerminalACS,Cubic,EIRRatio,PLR,,0.125,0.875,0,0,,,,,,,,,,,,,From .dat files included with MASControl2 -PTAC-Bypass-Factor-fAirflow,PkgdTerminalAC,Quadratic,QRatio,Airflow,,-2.28,5.21,-1.93,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -PTAC-Bypass-Factor-fEWB&EDB,PkgdTerminalAC,BiQuadratic,QRatio,EWB,EDB,-0.219664,0.0994608,0.00102,-0.020394,0.00036,-0.00120528,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -PTAC-Cool-Cap-fEWB&OAT,PkgdTerminalAC,BiQuadratic,QRatio,EWB,OAT,0.93865088,0.0095364,0.000684,-0.011038176,0.00000525,-0.00000972,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -PTAC-EIR-fEWB&OAT,PkgdTerminalAC,BiQuadratic,EIRRatio,EWB,OAT,0.34208928,0.03484368,-0.000625,0.004968864,0.000438,-0.000728,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -PTAC-EIR-fPLR,PkgdTerminalAC,Linear,EIRRatio,PLR,,0.125,0.875,,,,,,,,,,,,,,,From .dat files included with MASControl2 -PTAC-Sens-Cap-fAirflow,PkgdTerminalAC,Linear,QRatio,Airflow,,0.6,0.4,,,,,,,,,,,,,,,From .dat files included with MASControl2 -PTAC-Sens-Cap-fEWB&OAT,PkgdTerminalAC,BiQuadratic,QRatio,EWB,OAT,3.2722656,-0.14984352,0.00140292,0.0047124,-0.000162,0.000207,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -PTACHPACEIRFT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.342414409,0.034885008,-0.0006237,0.004977216,0.000437951,-0.000728028,,,,,12.77778,23.88889,18.3,46.11111,,,From DOE Reference Buildings SmallHotel -Pump-Head-fFlow,Pumps,Quadratic,QRatio,Flow,,1.3534831,33.8,-1660000,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Pump-Power-fFlow,Pumps,Quadratic,,Flow,,0.3697739,1780.65378,-943000,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -PVV240to760_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 -PVV240to760_BF_fT,BF_fT,BiQuadratic,,T,T,8.747712,-1.2544704,0.034992,0.219888,-0.00221292,-0.00284796,,,,,,,,,0,3.2,From .dat files included with MASControl2 -PVV240to760_CEIR_fPLR,CEIR_fPLR,Cubic,EIRRatio,PLR,,0.124,0.376,1.29,-0.794,,,,,,,,,,,,,From .dat files included with MASControl2 -PVV240to760_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,0.9521152,-0.01097712,0.0012312,-0.00072792,-0.0000454,-0.000173988,,,,,,,,,,,From .dat files included with MASControl2 -PVV240to760_CLoss_fPLR,CLoss_fPLR,Cubic,,PLR,,0,1,0,0,,,,,,,,,,,0.1,1,From .dat files included with MASControl2 -PVV240to760_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.91654848,0.0047736,-0.00233604,-0.013756896,-0.0000323,0.00057672,,,,,,,,,,,From .dat files included with MASControl2 -PVV240to760_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.380192,0.0241488,-0.00047952,0.0111168,0.00052488,-0.00102384,,,,,,,,,,,From .dat files included with MASControl2 -PVV240to760_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 -PVV240to760_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 -PVVT-Bypass-Factor-fAirflow,PkgdVVVT,Quadratic,QRatio,Airflow,,-0.254,1.22,0.036,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -PVVT-Bypass-Factor-fEWB&EDB,PkgdVVVT,BiQuadratic,QRatio,EWB,EDB,0.85028352,0.014256792,0.000184,-0.014791716,-0.00000548,0.000487,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -PVVT-Cool-Cap-fEWB&OAT,PkgdVVVT,BiQuadratic,QRatio,EWB,OAT,0.86783424,0.014239008,0.000554,-0.007558056,0.000033,-0.000192,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -PVVT-Cool-EIR-fEWB&OAT,PkgdVVVT,BiQuadratic,EIRRatio,EWB,OAT,0.1210048,0.0285336,-0.000411,0.02134944,0.000161,-0.00068,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -PVVT-Cool-EIR-fPLR,PkgdVVVT,Cubic,EIRRatio,PLR,,0.201,-0.0312,1.9504979,-1.1205104,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -PVVT-Heat-Cap-fEDB&OAT,PkgdVVVT,BiQuadratic,QRatio,EDB,OAT,0.74200928,0,0,0.030668544,0.0000323,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 -PVVT-Heat-EIR-fEDB&OAT,PkgdVVVT,BiQuadratic,EIRRatio,EDB,OAT,1.255664,0,0,-0.0399528,0.00108864,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 -PVVT-Heat-EIR-fPLR,PkgdVVVT,Cubic,EIRRatio,PLR,,0.0857,0.939,-0.183,0.159,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -PVVT-Sens-Cap-fEWB&OAT,PkgdVVVT,BiQuadratic,QRatio,EWB,OAT,2.93229888,-0.09445968,0.0002,-0.007173756,0.0000103,0.000109,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -Rcmp-kW-f-Tc-T1-Hi-Eff,Refrigeration,Quadratic,,Tc,,0.635620298,0.003533521,0.000161,,,,,,,,,,,,0.7533,1.2802,From .dat files included with MASControl2 -Rcmp-kW-f-Tc-T1-Low-Eff,Refrigeration,Quadratic,,Tc,,1.113461,-0.0308988,0.000739,,,,,,,,,,,,0.950084,1.606833,From .dat files included with MASControl2 -Rcmp-kW-f-Tc-T2-Hi-Eff,Refrigeration,Quadratic,,Tc,,0.580834119,0.00494838,0.000161,,,,,,,,,,,,0.7262,1.3046,From .dat files included with MASControl2 -Rcmp-kW-f-Tc-T2-Low-Eff,Refrigeration,Quadratic,,Tc,,0.970164,-0.02268,0.000625,,,,,,,,,,,,0.943908,1.565353,From .dat files included with MASControl2 -Rcmp-kW-f-Tc-T3-Hi-Eff,Refrigeration,Quadratic,,Tc,,0.358796196,0.007319986,0.000257,,,,,,,,,,,,0.5728,1.4917,From .dat files included with MASControl2 -Rcmp-kW-f-Tc-T3-Low-Eff,Refrigeration,Quadratic,,Tc,,0.656539,-0.0039924,0.00035,,,,,,,,,,,,0.941987,1.418136,From .dat files included with MASControl2 -Rcmp-kW2-f-Tc-T1-Hi-Eff,Refrigeration,Quadratic,,Tc,,0.904478102,-0.008972199,0.000303,,,,,,,,,,,,0.8518,1.2802,From .dat files included with MASControl2 -Rcmp-kW2-f-Tc-T1-Low-Eff,Refrigeration,Quadratic,,Tc,,1.113461,-0.0308988,0.000739,,,,,,,,,,,,0.950084,1.606833,From .dat files included with MASControl2 -Rcmp-kW2-f-Tc-T2-Hi-Eff,Refrigeration,Quadratic,,Tc,,0.887325182,-0.009516488,0.000328,,,,,,,,,,,,0.8326,1.3046,From .dat files included with MASControl2 -Rcmp-kW2-f-Tc-T2-Low-Eff,Refrigeration,Quadratic,,Tc,,0.970164,-0.02268,0.000625,,,,,,,,,,,,0.943908,1.565353,From .dat files included with MASControl2 -Rcmp-kW2-f-Tc-T3-Hi-Eff,Refrigeration,Quadratic,,Tc,,0.829593266,-0.014865914,0.000512,,,,,,,,,,,,0.7434,1.4917,From .dat files included with MASControl2 -Rcmp-kW2-f-Tc-T3-Low-Eff,Refrigeration,Quadratic,,Tc,,0.656539,-0.0039924,0.00035,,,,,,,,,,,,0.941987,1.418136,From .dat files included with MASControl2 -Rcond-Fan-Pwr-fPLR-ACpress,Refrigeration,Linear,,PLR,,0,1,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 -Rcond-Fan-Pwr-fPLR-Damper,Refrigeration,Linear,,PLR,,0.3,0.7,,,,,,,,,,,,,0.3,1,From .dat files included with MASControl2 -RecipAir-Cap-fCHWT&DBT,HermReciprocatg,BiQuadratic,QRatio,CHWT,DBT,1.10674018,0.040197888,0.000286,-0.009552852,0.00000522,-0.000255,,,,,,,,,,,From .dat files included with MASControl2 -RecipAir-EIR-fCHWT&DBT,HermReciprocatg,BiQuadratic,EIRRatio,CHWT,DBT,0.53866251,-0.008142246,0.000125,0.011090538,0.000164,-0.000342,,,,,,,,,,,From .dat files included with MASControl2 -RecipAir-EIR-fPLR-1Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.03892594,1.07531738,-0.10724027,-0.001050714,0.00000943,0.000536346,,,,,,,,,,,From .dat files included with MASControl2 -RecipAir-EIR-fPLR-2Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.04812248,0.69573414,0.2349389,0.000819378,-0.00000386,0.0000379,,,,,,,,,,,From .dat files included with MASControl2 -RecipAir-EIR-fPLR-3Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.03296722,0.57721251,0.33923307,0.002786436,-0.0000311,-0.000119,,,,,,,,,,,From .dat files included with MASControl2 -RecipAir-EIR-fPLR-4Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.00434876,0.61917436,0.32643354,0.003223368,-0.0000333,-0.000514206,,,,,,,,,,,From .dat files included with MASControl2 -RecipH2O-Cap-fCHWT&ECT,HermReciprocatg,BiQuadratic,QRatio,CHWT,ECT,1.0689798,0.036781398,0.000334,-0.010426122,0.0000217,-0.000208,,,,,,,,,,,From .dat files included with MASControl2 -RecipH2O-EIR-fCHWT&ECT,HermReciprocatg,BiQuadratic,EIRRatio,CHWT,ECT,0.51329254,-0.015039378,0.000362,0.015398694,0.000228,-0.000409,,,,,,,,,,,From .dat files included with MASControl2 -RecipH2O-EIR-fPLR&dT-1Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,-0.0142974,0.95360994,0.01805304,0.002822994,-0.0000199,-0.000497988,,,,,,,,,,,From .dat files included with MASControl2 -RecipH2O-EIR-fPLR&dT-2Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.02391765,0.88946915,0.07793053,-0.000474426,0.0000233,0.000324,,,,,,,,,,,From .dat files included with MASControl2 -RecipRemote-Cap-fCHWT&SCT,HermReciprocatg,BiQuadratic,QRatio,CHWT,SCT,1.27977199,0.051393222,0.000332,-0.009522792,-0.0000197,-0.000269,,,,,,,,,,,From .dat files included with MASControl2 -RecipRemote-EIR-fCHWT&SCT,HermReciprocatg,BiQuadratic,EIRRatio,CHWT,SCT,0.25314951,-0.015358788,0.000506,0.009717714,0.000171,-0.000382,,,,,,,,,,,From .dat files included with MASControl2 -RecipRemote-EIR-fPLR-1Comp/Ckt,HermReciprocatg,Quadratic,EIRRatio,PLR,,0.03521065,0.93266129,0.03212802,,,,,,,,,,,,,,From .dat files included with MASControl2 -RecipRemote-EIR-fPLR-2Comp/Ckt,HermReciprocatg,Quadratic,EIRRatio,PLR,,0.02511026,0.8934145,0.08147529,,,,,,,,,,,,,,From .dat files included with MASControl2 -Refg-Condenser-Cap-fCondT&WBT,Refrigeration,BiQuadratic,QRatio,CondT,WBT,0.15373327,0.00942813,0.000693,-0.020963196,-0.000702,0.000302,,,,,,,,,0.2,2.222,From .dat files included with MASControl2 -Refg-kW-fECT-T1,Refrigeration,Quadratic,,ECT,,0.753416,-0.0212148,0.000739,,,,,,,,,,,,0.850358,1.747334,From .dat files included with MASControl2 -Refg-kW-fECT-T2,Refrigeration,Quadratic,,ECT,,1.00323,-0.0290574,0.000765,,,,,,,,,,,,0.859029,1.592964,From .dat files included with MASControl2 -Refg-kW-fECT-T3,Refrigeration,Quadratic,,ECT,,0.671617,-0.0074358,0.000424,,,,,,,,,,,,0.873079,1.466883,From .dat files included with MASControl2 -Refg-kW-fPLR,Refrigeration,Quadratic,,PLR,,0.0383,1.08,-0.116129,,,,,,,,,,,,0.1,1.2,From .dat files included with MASControl2 -Refg-kW2-fECT-T1,Refrigeration,Quadratic,,ECT,,0.753416,-0.0212148,0.000739,,,,,,,,,,,,0.850358,1.747334,From .dat files included with MASControl2 -Refg-kW2-fECT-T2,Refrigeration,Quadratic,,ECT,,1.00323,-0.0290574,0.000765,,,,,,,,,,,,0.859029,1.592964,From .dat files included with MASControl2 -Refg-kW2-fECT-T3,Refrigeration,Quadratic,,ECT,,0.671617,-0.0074358,0.000424,,,,,,,,,,,,0.873079,1.466883,From .dat files included with MASControl2 -Residential Fix Vol-Fan EIR,FanEIR-FPLR,Linear,EIRRatio,PLR,,1,0,,,,,,,,,,,,,,,From .dat files included with MASControl2 -Residential Var Vol-Fan EIR,FanEIR-FPLR,Cubic,EIRRatio,PLR,,0.000281,-0.0579,0.586,0.471,,,,,,,,,,,,,From .dat files included with MASControl2 -RestaurantFastFood Kitchen_Case:1_WALKINFREEZERSingleShelfHorizontal_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.0236,0.0006,0,0,,,,,,,-35,20,,,,,From Prototype Buildings -RestaurantFastFood Kitchen_Case:2_SELFCONTAINEDDISPLAYCASEMultiShelfVertical_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,6.02558E-05,1.23732E-06,,,,,,,-35,20,,,,,From Prototype Buildings -RESVVT-Bypass-Factor-fAirflow,ResidentialVVVT,Quadratic,QRatio,Airflow,,-0.254,1.22,0.036,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -RESVVT-Bypass-Factor-fEWB&EDB,ResidentialVVVT,BiQuadratic,QRatio,EWB,EDB,0.85086272,0.014256792,0.000184,-0.014759136,-0.00000548,0.000487,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -RESVVT-Cool-Cap-fEWB&OAT,ResidentialVVVT,BiQuadratic,QRatio,EWB,OAT,0.47523136,0.04006368,0.000226,-0.000847152,-0.00000732,-0.000447,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -RESVVT-Cool-Cap-fRPM&OAT,ResidentialVVVT,BiQuadratic,QRatio,RPM,OAT,-686.394,-427.2546283,-66.38563967,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 -RESVVT-Cool-CondFan-fPLR&OAT,ResidentialVVVT,BiQuadratic,,PLR,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 -RESVVT-Cool-CycleLoss-fPLR,ResidentialVVVT,Linear,QRatio,PLR,,0.7,0.3,,,,,,,,,,,,,,,From .dat files included with MASControl2 -RESVVT-Cool-EIR-fEWB&OAT,ResidentialVVVT,BiQuadratic,EIRRatio,EWB,OAT,0.63153792,-0.012168288,0.000509,0.015536304,0.000273,-0.000679,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -RESVVT-Cool-EIR-fPLR,ResidentialVVVT,Linear,EIRRatio,PLR,,0,1,,,,,,,,,,,,,,,From .dat files included with MASControl2 -RESVVT-Cool-EIR-fRPM&OAT,ResidentialVVVT,BiQuadratic,EIRRatio,RPM,OAT,35.1027,10.50422626,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 -RESVVT-Cool-EIR-LoSpeed-fEWB&OAT,ResidentialVVVT,BiQuadratic,EIRRatio,EWB,OAT,0.77672128,-0.034271136,0.000784,0.01465956,0.000489,-0.000752,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -RESVVT-Cool-Waste-Heat-fEWB&OAT,ResidentialVVVT,BiLinear,QRatio,EWB,OAT,1,0,0,,,,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -RESVVT-Cool-Waste-Heat-fRPM&OAT,ResidentialVVVT,BiQuadratic,QRatio,RPM,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 -RESVVT-Heat-Cap-fEDB&OAT,ResidentialVVVT,BiQuadratic,QRatio,EDB,OAT,0.7716,0,0,0.02754,0,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 -RESVVT-Heat-Cap-fRPM&OAT,ResidentialVVVT,BiQuadratic,QRatio,RPM,OAT,-483.189,-303.9732093,-47.69188125,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 -RESVVT-Heat-CondFan-fPLR&OAT,ResidentialVVVT,BiQuadratic,,PLR,OAT,1,0,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 -RESVVT-Heat-CycleLoss-fPLR,ResidentialVVVT,Linear,QRatio,PLR,,0.75,0.25,,,,,,,,,,,,,,,From .dat files included with MASControl2 -RESVVT-Heat-EIR-fEDB&OAT,ResidentialVVVT,BiQuadratic,EIRRatio,EDB,OAT,1.1544,0,0,-0.02448,0.000729,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 -RESVVT-Heat-EIR-fPLR,ResidentialVVVT,Linear,EIRRatio,PLR,,0,1,,,,,,,,,,,,,,,From .dat files included with MASControl2 -RESVVT-Heat-EIR-fRPM&OAT,ResidentialVVVT,BiQuadratic,EIRRatio,RPM,OAT,31.9068,9.520648707,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 -RESVVT-Heat-EIR-LoSpeed-fEDB&OAT,ResidentialVVVT,BiQuadratic,EIRRatio,EDB,OAT,1.25435136,0,0,-0.040685472,0.001209784,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 -RESVVT-Heat-Waste-Heat-fEDB&OAT,ResidentialVVVT,BiLinear,QRatio,EDB,OAT,1,0,0,,,,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 -RESVVT-Heat-Waste-Heat-fRPM&OAT,ResidentialVVVT,BiQuadratic,QRatio,RPM,OAT,1,0,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 -RESVVT-Sens-Cap-fEWB&OAT,ResidentialVVVT,BiLinear,QRatio,EWB,OAT,2.78672,-0.08208,-0.005292,,,,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -RESYS-Bypass-Factor-fAirflow,Residential#1,Quadratic,QRatio,Airflow,,-3.01,6.59,-2.57,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -RESYS-Bypass-Factor-fEWB&EDB,Residential#1,BiQuadratic,QRatio,EWB,EDB,-1.1641344,0.20453184,-0.000603,-0.03036096,0.00036,-0.001464804,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -RESYS-Bypass-Factor-fPLR,ResidentialVVVT,Linear,QRatio,PLR,,1,0,,,,,,,,,,,,,,,From .dat files included with MASControl2 -RESYS-Cool-Cap-fEWB&OAT,Residential#1,BiQuadratic,QRatio,EWB,OAT,0.7665024,0.01076904,-0.0000415,0.00133848,-0.000261,0.000457,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -RESYS-Cool-EIR-fEWB&OAT,Residential#1,BiQuadratic,EIRRatio,EWB,OAT,0.29770688,0.04314528,-0.000748,0.005972688,0.000482,-0.000956,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -RESYS-Cool-EIR-fPLR,,Cubic,EIRRatio,PLR,,0.0000626,1.18,-0.202,0.0263344,,,,,,,,,,,,,From .dat files included with MASControl2 -RESYS-Heat-Cap-fEDB&OAT,Residential#1,BiQuadratic,QRatio,EDB,OAT,0.7516064,0,0,0.02799072,0.00019,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 -RESYS-Heat-EIR-fEDB&OAT,Residential#1,BiQuadratic,EIRRatio,EDB,OAT,1.231072,0,0,-0.0334944,0.000739,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 -RESYS-Heat-EIR-fPLR,Residential#1,Cubic,EIRRatio,PLR,,0.0857,0.939,-0.1834361,0.15897022,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -RESYS-Sens-Cap-fAirflow,Residential#1,Linear,QRatio,Airflow,,0.6,0.4,,,,,,,,,,,,,,,From .dat files included with MASControl2 -RESYS-Sens-Cap-fEWB&OAT,Residential#1,BiQuadratic,QRatio,EWB,OAT,3.3127968,-0.1617552,0.00184356,0.01027584,-0.000156,-0.0000284,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -SAC Heating Coil PLF-FPLR,DX Heating Coil,Cubic,EIRRatio,QRatio,,0.8,0.2,0,0,,,,,,,0,1,,,,,From Prototype Buildings -SchoolPrimary Kitchen_ZN_1_FLR_1_Case:1_WALKINFREEZERSingleShelfHorizontal_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.0236,0.0006,0,0,,,,,,,-35,20,,,,,From Prototype Buildings -SchoolPrimary Kitchen_ZN_1_FLR_1_Case:2_SELFCONTAINEDDISPLAYCASEMultiShelfVertical_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,6.02558E-05,1.23732E-06,,,,,,,-35,20,,,,,From Prototype Buildings -ScrewAir-Cap-fCHWT&DBT,Screw,BiQuadratic,QRatio,CHWT,DBT,0.97878647,0.02387169,0.000587,-0.0000478,-0.000112,-0.00011,,,,,,,,,,,From .dat files included with MASControl2 -ScrewAir-EIR-fCHWT&DBT,Screw,BiQuadratic,EIRRatio,CHWT,DBT,0.6729704,-0.005730012,0.000702,-0.00119601,0.00044,-0.000699,,,,,,,,,,,From .dat files included with MASControl2 -ScrewAir-EIR-fPLR&dT-1Comp/Ckt,Screw,BiQuadratic,EIRRatio,PLR,dT,0.01040687,1.05183303,-0.09462459,0.002943774,-0.0000252,-0.001085832,,,,,,,,,,,From .dat files included with MASControl2 -ScrewAir-EIR-fPLR&dT-2Comp/Ckt,Screw,BiQuadratic,EIRRatio,PLR,dT,0.09611014,0.72898877,0.19517007,-0.000729072,0.00000667,-0.000175,,,,,,,,,,,From .dat files included with MASControl2 -ScrewH2O-Cap-fCHWT&ECT,Screw,BiQuadratic,QRatio,CHWT,ECT,1.07096667,0.02693502,0.000768,-0.00643302,-0.0000949,-0.0000659,,,,,,,,,,,From .dat files included with MASControl2 -ScrewH2O-EIR-fCHWT&ECT,Screw,BiQuadratic,EIRRatio,CHWT,ECT,0.59849788,-0.00123345,0.000563,0.001602738,0.000636,-0.001094148,,,,,,,,,,,From .dat files included with MASControl2 -ScrewH2O-EIR-fPLR&dT-1Comp/Ckt,Screw,BiQuadratic,EIRRatio,PLR,dT,-0.11699212,1.2635448,-0.2194667,0.005301648,0.0000547,-0.003346506,,,,,,,,,,,From .dat files included with MASControl2 -ScrewH2O-EIR-fPLR&dT-2Comp/Ckt,Screw,BiQuadratic,EIRRatio,PLR,dT,-0.27111483,1.49009538,-0.33198115,0.017556084,-0.000191,-0.008247186,,,,,,,,,,,From .dat files included with MASControl2 -ScrewRemote-Cap-fCHWT&SCT,Screw,BiQuadratic,QRatio,CHWT,SCT,1.16410009,0.048370122,0.000493,-0.002428218,-0.000109,-0.000269,,,,,,,,,,,From .dat files included with MASControl2 -ScrewRemote-EIR-fCHWT&SCT,Screw,BiQuadratic,EIRRatio,CHWT,SCT,0.79518287,-0.009101466,0.001707804,-0.015352632,0.000488,-0.000932,,,,,,,,,,,From .dat files included with MASControl2 -ScrewRemote-EIR-fPLR-1Comp/Ckt,Screw,Quadratic,EIRRatio,PLR,,0.07043035,1.01683199,-0.08726242,,,,,,,,,,,,,,From .dat files included with MASControl2 -ScrewRemote-EIR-fPLR-2Comp/Ckt,Screw,Quadratic,EIRRatio,PLR,,0.08138224,0.72724819,0.19136968,,,,,,,,,,,,,,From .dat files included with MASControl2 -ScrollChlrAirCoolCap-fCHW&OAT,Chiller,BiQuadratic,QRatio,CHWT,OAT,1.05229229,0.033560892,0.000215,-0.005180832,-0.0000442,-0.000215,,,,,,,,,,,From .dat files included with MASControl2 -ScrollChlrAirCoolEIR-fCHW&OAT,Chiller,BiQuadratic,EIRRatio,CHWT,OAT,0.58333562,-0.004036194,0.000468,-0.000224478,0.000481,-0.000682,,,,,,,,,,,From .dat files included with MASControl2 -ScrollChlrAirCoolEIR-fPLR,Chiller,Quadratic,EIRRatio,PLR,,0.03366649,0.53152555,0.43480802,,,,,,,,,,,,,,From .dat files included with MASControl2 -Si-Film_Spectral-fAirMass,PV-Module,Cubic,,AirMass,,0.95691782,0.04079713,-0.00869376,0.00042887,,,,,,,,,,,,,From .dat files included with MASControl2 -Single Shelf Horizontal Latent Energy Multiplier_After2004,Refrigerated Case,Cubic,,,,0.0236,0.0006,0,0,,,,,,,-35,20,,,,,From Reference Buildings -Single Shelf Horizontal Latent Energy Multiplier_Pre2004,Refrigerated Case,Cubic,,,,0.020376,0.00024378,0.0000114,1.811E-07,,,,,,,-35,20,,,,,From Reference Buildings -Single zone VAV fan,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.027827882,0.026583195,-0.0870687,1.03091975,,,,,,,0,1,,,0.1,,Baseline for System Type 11 from ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method -Small-CHW-Bypass-fAirflow,CHWCoils,Quadratic,QRatio,Airflow,,-0.718,1.91,-0.189,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Small-CHW-Coil-Bypass-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,1.09657216,0.001908,0.000369,-0.005647032,0.0000246,-0.000277,,,,,15.55556,29.44444,12.77778,29.44444,,,From .dat files included with MASControl2 -Small-CHW-Coil-Cap-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,-0.282048,-0.022212,0.0054432,0.0297216,0.000804,-0.0033372,,,,,15.55556,29.44444,12.77778,29.44444,,,From .dat files included with MASControl2 -Small-CHW-Sens-Cap-fAirflow,CHWCoils,Quadratic,QRatio,Airflow,,0.155,1.01,-0.16,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Small-CHW-Sens-Cap-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,-0.415152,-0.0405576,0.00140616,0.086508,0.000444,-0.00184356,,,,,12.77778,29.44444,12.77778,29.44444,,,From .dat files included with MASControl2 -Smooth_Optical-fAOI,PV-Module,Cubic,,AOI,,3.76248479,-0.15946805,0.00302191,-0.0000191,,,,,,,,,,,,,From .dat files included with MASControl2 -Split DX Coil EIR-FF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.1552,-0.1808,0.0256,,,,,,,,0.5,1.5,,,,,"From PNNL Prototype Buildings ApartmentMidRise, HotelSmall, Warehouse" -SpltAC1Sp_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 -SpltAC1Sp_BF_fT,BF_fT,BiQuadratic,,T,T,8.513632,-0.630072,0.0165888,-0.0450144,0.00107892,-0.0018954,,,,,,,,,0,3.33,From .dat files included with MASControl2 -SpltAC1Sp_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0.00007,1.23,-0.307,0.0756,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,0.00012,1.2,-0.261,0.0596,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.00007,1.17,-0.213,0.0438,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,0.67916,0.016938,0.00069336,0.0045576,-0.0000842,-0.00047628,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC1Sp_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.805,0.233,-0.038,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.827,0.203,-0.03,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.852,0.17,-0.0219,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.7311616,-0.10297296,0.00093636,0.00477864,-0.0000907,-0.000202824,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.7390464,-0.00778968,0.000128304,-0.00027,0.0006642,-0.000648,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC1Sp_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC1Sp_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC1Sp-ge45_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 -SpltAC1Sp-ge45_BF_fT,BF_fT,BiQuadratic,,T,T,16.900064,-1.747584,0.050544,0.1428912,0.00048924,-0.0090396,,,,,,,,,0,3.76,From .dat files included with MASControl2 -SpltAC1Sp-ge45_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0,1.18,-0.223,0.0468,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-ge45_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,0.00008,1.15,-0.183,0.0343,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-ge45_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.0001,1.12,-0.14,0.0225,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-ge45_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.2403136,-0.0346752,0.00187596,0.00106848,-0.000057,-0.0003564,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC1Sp-ge45_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.847,0.177,-0.0235,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-ge45_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.869,0.149,-0.0172,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-ge45_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.893,0.118,-0.0112,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-ge45_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.8260768,0.0199944,-0.00284148,-0.01422576,-0.0000577,0.00064152,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-ge45_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.093776,0.0674784,-0.00192132,-0.0031176,0.00067068,-0.0005832,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC1Sp-ge45_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC1Sp-ge45_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC1Sp-lt45_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 -SpltAC1Sp-lt45_BF_fT,BF_fT,BiQuadratic,,T,T,22.932224,-2.291616,0.063504,0.0800712,0.00076464,-0.0068364,,,,,,,,,0,3.3,From .dat files included with MASControl2 -SpltAC1Sp-lt45_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0,1.18,-0.223,0.0468,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-lt45_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,0.00008,1.15,-0.183,0.0343,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-lt45_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.0001,1.12,-0.14,0.0225,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-lt45_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.1299744,-0.0222336,0.0015228,-0.0000353,-0.0000434,-0.00032724,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC1Sp-lt45_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.847,0.177,-0.0235,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-lt45_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.869,0.149,-0.0172,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-lt45_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.893,0.118,-0.0112,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-lt45_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.4985024,0.0478512,-0.0034992,-0.01084968,-0.0000548,0.00047628,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-lt45_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.09712,0.0536256,-0.00144828,0.0040644,0.00062208,-0.000729,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC1Sp-lt45_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC1Sp-lt45_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC2SpHiSEER_BF_fFlow,BF_fFlow,Linear,,Flow,,1.75,-1578.5656,,,,,,,,,,,,,1,1.189,From .dat files included with MASControl2 -SpltAC2SpHiSEER_BF_fT,BF_fT,BiQuadratic,,T,T,20.03024,-1.922832,0.051516,0.086184,0.0011502,-0.0076788,,,,,,,,,0,3.92,From .dat files included with MASControl2 -SpltAC2SpHiSEER_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0.00635,1.12,-0.139,0.016,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpHiSEER_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,-0.00144,1.12,-0.14,0.022,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpHiSEER_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.00726,1.11,-0.132,0.0262,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpHiSEER_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.5240096,-0.0665928,0.00299376,0.00162288,-0.0000651,-0.00048924,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC2SpHiSEER_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.923,0.153,-0.0156,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpHiSEER_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.94,0.124,-0.0109,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpHiSEER_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.959,0.0934,-0.00688,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpHiSEER_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.54,0.0382752,-0.00297756,-0.0114912,-0.00010044,0.0005346,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpHiSEER_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,-0.172512,0.1176624,-0.00324,-0.01152,0.00077112,-0.00057024,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC2SpHiSEER_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC2SpHiSEER_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC2SpLoSEER_BF_fFlow,BF_fFlow,Linear,,Flow,,1.75,-1578.5656,,,,,,,,,,,,,1,1.189,From .dat files included with MASControl2 -SpltAC2SpLoSEER_BF_fT,BF_fT,BiQuadratic,,T,T,10.820416,-1.041264,0.0254988,0.2290608,0.00062856,-0.0117612,,,,,,,,,0,5.76,From .dat files included with MASControl2 -SpltAC2SpLoSEER_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,-0.00016,1.12,-0.143,0.0206,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpLoSEER_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,-0.00146,1.1,-0.119,0.0176,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpLoSEER_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,0.00284,1.06,-0.0687,0.00523,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpLoSEER_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.54887488,-0.0648072,0.00310068,-0.000425376,-0.0000255,-0.00060264,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC2SpLoSEER_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.856,0.121,-0.0124,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpLoSEER_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.872,0.0941,-0.00752,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpLoSEER_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.889,0.0695,-0.00646,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpLoSEER_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.322048,-0.0286956,-0.00124092,-0.020124,-0.0000405,0.0006804,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpLoSEER_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,-0.281376,0.1343088,-0.0036936,-0.0173736,0.00096552,-0.00075168,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC2SpLoSEER_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC2SpLoSEER_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltACEvap_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 -SpltACEvap_BF_fT,BF_fT,BiQuadratic,,T,T,16.06,-1.566,0.0405,1.75E-10,3.24E-12,3.24E-12,,,,,,,,,0,3.97,From .dat files included with MASControl2 -SpltACEvap_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0,1,0,0,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltACEvap_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,0,1,0,0,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltACEvap_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,0,1,0,0,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltACEvap_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,0.6302064,0.0171576,0.00069012,-0.00374688,0.000212544,-0.0005508,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltACEvap_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.94,0.06,0,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltACEvap_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.97,0.03,0,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltACEvap_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,1,0,0,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltACEvap_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.9516064,-0.0154008,-0.0012798,-0.00110088,0.000194724,-0.00054432,,,,,,,,,,,From .dat files included with MASControl2 -SpltACEvap_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,1.207232,-0.0528552,0.00053136,0.0261288,-0.00045684,0.0005508,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltACEvap_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltACEvap_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltHP1SpCom_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 -SpltHP1SpCom_BF_fT,BF_fT,BiQuadratic,,T,T,8.513632,-0.630072,0.0165888,-0.0450144,0.00107892,-0.0018954,,,,,,,,,0,3.33,From .dat files included with MASControl2 -SpltHP1SpCom_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0.00007,1.23,-0.307,0.0756,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpCom_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,0.00012,1.2,-0.261,0.0596,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpCom_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.00007,1.17,-0.213,0.0438,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpCom_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,0.67916,0.016938,0.00069336,0.0045576,-0.0000842,-0.00047628,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltHP1SpCom_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.805,0.233,-0.038,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpCom_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.827,0.203,-0.03,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpCom_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.852,0.17,-0.0219,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpCom_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.7311616,-0.10297296,0.00093636,0.00477864,-0.0000907,-0.000202824,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpCom_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.7390464,-0.00778968,0.000128304,-0.00027,0.0006642,-0.000648,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltHP1SpCom_HIR_fT,HIR_fT,BiQuadratic,,T,T,0.8186976,0.01406952,0.000117936,-0.01579104,0.000222264,-0.000300024,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltHP1SpCom_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0.85516576,-0.003631392,-0.00000619,0.02644704,0.00041148,-0.000141264,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltHP1SpRes_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 -SpltHP1SpRes_BF_fT,BF_fT,BiQuadratic,,T,T,8.513632,-0.630072,0.0165888,-0.0450144,0.00107892,-0.0018954,,,,,,,,,0,3.33,From .dat files included with MASControl2 -SpltHP1SpRes_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0.00007,1.23,-0.307,0.0756,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpRes_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,0.00012,1.2,-0.261,0.0596,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpRes_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.00007,1.17,-0.213,0.0438,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpRes_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,0.67916,0.016938,0.00069336,0.0045576,-0.0000842,-0.00047628,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltHP1SpRes_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.805,0.233,-0.038,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpRes_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.827,0.203,-0.03,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpRes_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.852,0.17,-0.0219,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpRes_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.7311616,-0.10297296,0.00093636,0.00477864,-0.0000907,-0.000202824,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpRes_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.7390464,-0.00778968,0.000128304,-0.00027,0.0006642,-0.000648,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltHP1SpRes_HIR_fT,HIR_fT,BiQuadratic,,T,T,0.9003872,0.01108728,0.0001701,-0.02579472,0.0008424,-0.000290628,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltHP1SpRes_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0.9303344,-0.0064656,0.0000177,0.02813472,-0.00000551,-0.000208656,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltHP2Sp_BF_fFlow,BF_fFlow,Linear,,Flow,,1.75,-1578.5656,,,,,,,,,,,,,1,1.189,From .dat files included with MASControl2 -SpltHP2Sp_BF_fT,BF_fT,BiQuadratic,,T,T,20.03024,-1.922832,0.051516,0.086184,0.0011502,-0.0076788,,,,,,,,,0,3.92,From .dat files included with MASControl2 -SpltHP2Sp_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0.00635,1.12,-0.139,0.016,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP2Sp_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,-0.00144,1.12,-0.14,0.022,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP2Sp_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.00726,1.11,-0.132,0.0262,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP2Sp_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.5240096,-0.0665928,0.00299376,0.00162288,-0.0000651,-0.00048924,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltHP2Sp_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.923,0.153,-0.0156,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP2Sp_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.94,0.124,-0.0109,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP2Sp_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.959,0.0934,-0.00688,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP2Sp_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.54,0.0382752,-0.00297756,-0.0114912,-0.00010044,0.0005346,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP2Sp_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,-0.172512,0.1176624,-0.00324,-0.01152,0.00077112,-0.00057024,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltHP2Sp_HIR_fT,HIR_fT,BiQuadratic,,T,T,0.9272864,0.00802008,0.000201528,-0.02177136,0.000729,-0.000303264,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltHP2Sp_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0.8756304,-0.00466344,1.62E-14,0.02912976,0.00012636,-0.000163296,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SteamTurbine-Flow-fPSIG,SteamTurbineGen,BiQuadratic,QRatio,PSIG,PSIG,38.79236,-0.0000307,1.11E-11,0.000147951,1.93E-11,-7.36E-11,,,,,,,,,18,100,From .dat files included with MASControl2 -SteamTurbine-HIR-fPLR,SteamTurbineGen,Quadratic,,PLR,,0.12838545,0.90049523,-0.02888074,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Stippled_Optical-fAOI,PV-Module,Cubic,,AOI,,4.70208168,-0.21138079,0.00393233,-0.000024,,,,,,,,,,,,,From .dat files included with MASControl2 -SWH-EFFFPLR-NECB2011,Water Heater,Cubic,FIRRatio,QRatio,,0.7576,1.0071,-1.4443,0.6844,,,,,,,0,1,,,,,From NECB 2011 -Tower_Fan_Curve,,Cubic,,,,0,0,0,1,,,,,,,0,1,,,,,From Prototype Buildings -Transformer-Loss-fPLR,ElecMeters,Linear,QRatio,PLR,,0.1,0.9,,,,,,,,,,,,,,,From .dat files included with MASControl2 -Two-Speed Fan EIR fPLR,FanEIR-FPLR,Linear,,PLR,,-0.764706,1.764706,,,,,,,,,,,,,0.4,,From .dat files included with MASControl2 -TwoSpeedFan,FanEIR-FPLR,Cubic,EIRRatio,PLR,,0.000281,-0.0579,0.586,0.471,,,,,,,,,,,,,From .dat files included with MASControl2 -Typical VSD Fan,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.047182815,0.130541742,-0.117286942,0.940313747,,,,,,,0,1,,,0.1,,"From California Energy Commision, ""Advanced Variable Air Volume System Design Guide,"" October 2003" -TypicalCyclingAC-EIR-fPLR,CyclingAC,Cubic,EIRRatio,PLR,,0.0000626,1.17517,-0.201513,0.0263344,,,,,,,,,,,,,From .dat files included with MASControl2 -Vane Axial w Var Pitch FPLR,FanEIR-FPLR,Quadratic,,PLR,,0.212048,-0.569286,1.345238,,,,,,,,,,,,0.15,1,From .dat files included with MASControl2 -Variable Speed Drive FPLR,FanEIR-FPLR,Quadratic,,PLR,,0.219762,-0.874784,1.652597,,,,,,,,,,,,0.1,1,From .dat files included with MASControl2 -VarVolFan-AFBIFanCurve-NECB2011-FPLR,Fan,Cubic,PwrRatio,FlowRatio,,-2.4176,9.5874,-11.559,5.4009,,,,,,,0.68,1,,,,,From NECB 2011 -VarVolFan-AFBIInletVanes-NECB2011-FPLR,Fan,Cubic,PwrRatio,FlowRatio,,-4.1457,16.803,-19.471,7.8488,,,,,,,0.5,1,,,,,From NECB 2011 -VarVolFan-FCInletVanes-NECB2011-FPLR,Fan,Cubic,PwrRatio,FlowRatio,,-0.3477,4.0976,-5.0024,2.268,,,,,,,0.22,1,,,,,From NECB 2011 -VarVolFan-VSD-NECB2011-FPLR,Fan,Cubic,PwrRatio,FlowRatio,,0.1389,1.7699,-1.615,0.6996,,,,,,,0.04,1,,,,,From NECB 2011 -VFD-Loss-fPLR,Pumps,Linear,QRatio,PLR,,0.6,0.4,,,,,,,,,,,,,,,From .dat files included with MASControl2 -VRF-HP-Resys-ClCap-fSST&ODB,CondUnit,BiQuadratic,QRatio,SST,ODB,1.26588416,0,0,-0.007582032,-0.00000214,0,,,,,,,,,,,From .dat files included with MASControl2 -VRF-HP-Resys-ClEIR-fSST&ODB,CondUnit,BiQuadratic,EIRRatio,SST,ODB,0.384832,0,0,0.0092304,0.000238,0,,,,,,,,,,,From .dat files included with MASControl2 -VRF-HP-Resys-Crankcase-fPLR,CondUnit,Quadratic,,PLR,,1,-1.72,0.72,,,,,,,,,,,,,,From .dat files included with MASControl2 -VRF-HP-Resys-Cycle-fPLR,CondUnit,Linear,QRatio,PLR,,0.898,0.102,,,,,,,,,,,,,,,From .dat files included with MASControl2 -VRF-HP-Resys-HtCap-fSCT&OWB,CondUnit,BiQuadratic,QRatio,SCT,OWB,0.89783456,0,0,0.016707888,0.000000616,0,,,,,,,,,,,From .dat files included with MASControl2 -VRF-HP-Resys-HtEIR-fSCT&OWB,CondUnit,BiQuadratic,EIRRatio,SCT,OWB,1.0525344,0,0,-0.00815688,-0.0000872,0,,,,,,,,,,,From .dat files included with MASControl2 -VSD-TWR-FAN-FPLR,Cooling Tower,Cubic,,,,0.33162901,-0.88567609,0.60556507,0.9484823,,,,,,,0,1,,,,,From PNNL PRM Reference Manual -Water-Cooled-Bypass-fAirflow,"DXCooling,WCC",Cubic,QRatio,Airflow,,0.9,-3.73,7.37,-3.54,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Water-Cooled-Bypass-fEWB&EWT,"DXCooling,WCC",BiQuadratic,QRatio,EWB,EWT,-5.51104768,0.73563552,-0.0185004,0.142520616,0.000942,-0.010213452,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -Water-Cooled-Cool-Cap-fEWB&EWT,"DXCooling,WCC",BiQuadratic,QRatio,EWB,EWT,0.8254384,0.00574416,0.000735,-0.00310374,-0.0000146,-0.000194,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -Water-Cooled-EIR-fEWB&EWT,"DXCooling,WCC",BiQuadratic,EIRRatio,EWB,EWT,0.0985984,0.062604,-0.00184356,0.01183032,0.000292,-0.000395,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -Water-Cooled-EIR-fPLR,"DXCooling,WCC",Cubic,EIRRatio,PLR,,0.201,-0.0312,1.9504979,-1.1205104,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Water-Cooled-Sens-Cap-fEWB&EWT,"DXCooling,WCC",BiQuadratic,QRatio,EWB,EWT,2.1542784,-0.0242784,-0.00148716,-0.00829548,-0.0000296,0.000272,,,,,12.77778,29.44444,10,46.11111,,,From .dat files included with MASControl2 -WaterCooled_Centrifugal_CAPFT_NECB2011,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.707908,-0.00200657,-0.00259605,0.0300588,-0.00105643,0.0020457,,,,,5,10,24,35,,,From NECB 2011 -WaterCooled_Centrifugal_Chiller_150TO300_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_150TO300_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_150TO300_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.7600172,0.0147432,0.0002144,0.0207218,-0.0006425,0.0008007,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.6772577,0.0117857,-0.0001967,0.0014414,0.0003005,-0.0006807,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.536234,0.005581,-0.0013654,0.0488966,-0.0012018,0.0010523,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,1.0821822,0.0042977,-0.0013182,-0.0260781,0.0008256,-0.0006013,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_300TO600_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_300TO600_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_AllCapacities_2004_2007_2010_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010. EIRFPLR curve is identical for all WaterCooled Chillers" -WaterCooled_Centrifugal_Chiller_GT150_2004_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.7600172,0.0147432,0.0002144,0.0207218,-0.0006425,0.0008007,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_GT150_2004_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.6772577,0.0117857,-0.0001967,0.0014414,0.0003005,-0.0006807,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_GT300_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_GT600_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_GT600_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_LT150_2004_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.7446451,0.0114858,0.0000148,0.022401,-0.000688,0.0009839,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.772877,0.022101,-0.0000799,-0.0070045,0.0004763,-0.0010612,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_LT150_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_LT150_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_EIRFPLR_NECB2011,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.171493,0.588202,0.237373,,,,,,,,0,1,,,,,From NECB 2011 -WaterCooled_Centrifugal_EIRFT_NECB2011,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.560523,-0.0137816,6.56424E-05,0.0132194,0.000268596,-0.000501131,,,,,5,10,24,35,,,From NECB 2011 -WaterCooled_PositiveDisplacement_Chiller_150TO300_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_150TO300_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_150TO300_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_2004_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.906115,0.029227,-0.0003647,-0.0009709,-0.0000905,0.0002527,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_2004_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.3617105,-0.0229833,0.0009519,0.0131889,0.0003752,-0.0007059,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_2010_PathB_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.9061171,0.0292267,-0.0003665,-0.0009698,-0.0000907,0.0002535,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_2010_PathB_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.3617782,-0.0230016,0.0009672,0.0131801,0.0003761,-0.0007121,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_75TO150_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_75TO150_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_75TO150_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.906115,0.0292277,-0.0003647,-0.0009709,-0.0000905,0.0002527,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.3773115,-0.0229032,0.0016504,0.0118156,0.0004345,-0.0010132,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_GT300_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_GT300_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_GT300_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.906115,0.0292277,-0.0003647,-0.0009709,-0.0000905,0.0002527,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.3617105,-0.0229833,0.0009519,0.0131889,0.0003752,-0.0007059,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_LT75_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_LT75_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_LT75_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558E-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Reciprocating_CAPFT_NECB2011,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.03031,0.0334698,0.00023639,-0.00729587,-0.000023166,-0.000148943,,,,,5,10,24,35,,,From NECB 2011 -WaterCooled_Reciprocating_EIRFPLR_NECB2011,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.081441,0.419271,0.499396,,,,,,,,0,1,,,,,From NECB 2011 -WaterCooled_Reciprocating_EIRFT_NECB2011,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.499699,-0.0130841,0.000266425,0.0165925,0.000185393,-0.000375646,,,,,5,10,24,35,,,From NECB 2011 -WaterCooled_Screw_CAPFT_NECB2011,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.812998,-0.0142532,-0.00161799,0.0263844,-0.00091543,0.00169601,,,,,5,10,24,35,,,From NECB 2011 -WaterCooled_Screw_EIRFPLR_NECB2011,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.330188,0.235543,0.460708,,,,,,,,0,1,,,,,From NECB 2011 -WaterCooled_Screw_EIRFT_NECB2011,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.638103,0.00630158,0.00092327,-0.00455294,0.000825682,-0.00156152,,,,,5,10,24,35,,,From NECB 2011 -WaterCooled_Scroll_CAPFT_NECB2011,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.94418,0.0337102,9.75564E-05,-0.00322114,-4.91832E-05,-0.000177584,,,,,5,10,24,35,,,From NECB 2011 -WaterCooled_Scroll_EIRFPLR_NECB2011,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.04412,0.640367,0.319555,,,,,,,,0,1,,,,,From NECB 2011 -WaterCooled_Scroll_EIRFT_NECB2011,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.727393,-0.0118922,0.000541177,0.00187934,0.000473461,-0.000711472,,,,,5,10,24,35,,,From NECB 2011 -WC Screw Default 90.1-2004 Cap_fTWC,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.906115,0.0292277,-0.0003647,-0.0009709,-0.0000905,0.0002527,,,,,0,20,0,50,,,From RefBldgLargeOfficePost1980 & Pre1980 -WC Screw Default 90.1-2004 EIR_fT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.3617105,-0.0229833,-0.0009519,0.0131889,0.0003752,-0.0007059,,,,,0,20,0,50,,,From RefBldgLargeOfficePost1980 % Pre1980 -WC Screw GTE 300tons Default 90.1-2004 EIR_fPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.2737954,0.02822257,-8.09766E-05,0.9612284,0.3029741,-0.02421933,0,-0.03885224,0,0,18.54,31.63,0.2,1.02,,,From RefBldgLargeOfficePost1980 & Pre1980 -WC_PD_2004_CAPFT,,BiQuadratic,,,,0.906115,0.0292277,-0.0003647,-0.0009709,-0.0000905,0.0002527,,,,,5,10,17.78,46.11,,,From PNNL Prototype Hospital -WC_PD_2010_PB_CAPFT,,BiQuadratic,,,,0.9061171,0.0292267,-0.0003665,-0.0009698,-0.0000907,0.0002535,,,,,5,10,17.78,46.11,,,From PNNL Prototype OfficeLarge -WC_PD_2010_PB_EIRFT,,BiQuadratic,,,,0.3617782,-0.0230016,0.0009672,0.0131801,0.0003761,-0.0007121,,,,,5,10,17.78,46.11,,,From PNNL Prototype OfficeLarge -MT_compressor_power,Refrigeration,BiCubic,Power,Suction T,Discharge T,7438.92229,-269.59756,-9.8561045,553.57326,-3.3858896,14.8657878,-0.1007963,0.00982279,0.09736236,-0.039675217,-23.3,7.2,10,60,,,From AEDG -MT_compressor_capacity,Refrigeration,BiCubic,Capacity,Suction T,Discharge T,151166.436,5266.34789,60.6727151,-1851.5594,5.73132755,-46.927717,0.1364012,-0.0356979,-0.403054,-0.039290478,-23.3,-7.2,10,60,,,From AEDG -MT_compressor_capacity_smallandold,Refrigeration,BiCubic,Capacity,Suction T,Discharge T,15000,541.8,7.285,-118,-0.3645,-3.05,0.0344,0.00225,-0.03927,-0.007307,-17.8,4.4,10,48.9,,,From EP DataSets -MT_compressor_power_smallandold,Refrigeration,BiCubic,Power,Suction T,Discharge T,483.6,-53.2,-1.384,56.19,0.003688,1.439,-0.008268,-0.00281,0.007222,0.006025,-17.8,4.4,10,48.9,,,From EP DataSets -LT_compressor_capacity_smallandold,Refrigeration,BiCubic,Capacity,Suction T,Discharge T,23500,816.7,10.7,-28.24,0.1131,-0.4553,0.05604,-0.00412,-0.006728,0.006782,-40,-17.8,10,48.9,,,From EP DataSets -LT_compressor_power_smallandold,Refrigeration,BiCubic,Power,Suction T,Discharge T,4018,95,1.507,5.705,1.247,-1.381,0.01277,-0.007518,-0.02424,0.02917,-40,-17.8,10,48.9,,,From EP DataSets -Glass Door Latent Curve Case,Refrigeration,Cubic,,,,0.3379,0.0309,0.0005,0.00004,,,,,,,-55,55,,,,,From AEDG -Coffin Latent Curve Case,Refrigeration,Cubic,,,,0.3379,0.0309,0.0005,0.00004,,,,,,,-55,55,,,,,From AEDG -Open Latent Curve Case,Refrigeration,Cubic,,,,-0.0187,0.0458,0.0011,0.00005,,,,,,,-55,55,,,,,From AEDG -Glass Door Defrost Curve Walkin,Refrigeration,Cubic,,,,0.3475,0.0296,0.0007,0.00003,,,,,,,-55,55,,,,,From AEDG -Coffin Defrost Curve Walkin,Refrigeration,Cubic,,,,0.3475,0.0296,0.0007,0.00003,,,,,,,-55,55,,,,,From AEDG -Open Defrost Curve Walkin,Refrigeration,Cubic,,,,0.0572,0.0461,0.0004,0.00006,,,,,,,-55,55,,,,,From AEDG -Refrigeration Case Latent Credit Curve,Refrigeration,Cubic,,,,0.026526281,0.001078032,6.02558E-05,1.23732E-06,,,,,,,-35,20,,,,, diff --git a/data/openstudio_standards_data/initial_data/support_standard_templates.csv b/data/openstudio_standards_data/initial_data/support_standard_templates.csv deleted file mode 100644 index 66f2b3ab50..0000000000 --- a/data/openstudio_standards_data/initial_data/support_standard_templates.csv +++ /dev/null @@ -1,3 +0,0 @@ -id,template,lighting_standard,lighting_standard_table,ventilation_standard,ventilation_standard_table -1,90.1-2019,ASHRAE 90.1-2019,level_3_lighting_90_1_2019,ASHRAE 62.1-2019,level_3_ventilation_90_1_2019 -2,90.1-2004,ASHRAE 90.1-2004,level_3_lighting_90_1_2004,ASHRAE 62.1-2004,level_3_ventilation_90_1_2004 diff --git a/data/openstudio_standards_data/initial_data/support_ventilation_space_type_name_tags.csv b/data/openstudio_standards_data/initial_data/support_ventilation_space_type_name_tags.csv deleted file mode 100644 index 071f84481d..0000000000 --- a/data/openstudio_standards_data/initial_data/support_ventilation_space_type_name_tags.csv +++ /dev/null @@ -1,111 +0,0 @@ -ventilation_space_type_name -correctional_facilities_cell -correctional_facilities_dayroom -correctional_facilities_guard_stations -correctional_facilities_booking_waiting -educational_facilities_daycare -educational_facilities_classroom_young -educational_facilities_classroom_old -educational_facilities_lecture_classroom -educational_facilities_lecture_hall -educational_facilities_art_classroom -educational_facilities_science_laboratories -educational_facilities_wood_metal_shop -educational_facilities_computer_lab -educational_facilities_media_center -educational_facilities_music_theater_dance -educational_facilities_multiuse_assembly -educational_facilities_daycare_sickroom -educational_facilities_libraries -educational_facilities_university_college_laboratories -food_beverage_service_restaurant_dining_rooms -food_beverage_service_cafeteria_fast_food_dining -food_beverage_service_bars_cocktail_lounges -food_beverage_service_kitchen -general_conference_meeting -general_conference_corridors -general_conference_storage_rooms -general_break_rooms -general_coffee_stations -hotels_motels_resorts_dormitories_bedroom_living_room -hotels_motels_resorts_dormitories_barracks_sleeping_areas -hotels_motels_resorts_dormitories_lobbies_prefunction -hotels_motels_resorts_dormitories_multi_purpose_assembly -hotels_motels_resorts_dormitories_laundry_rooms -hotels_motels_resorts_dormitories_laundry_rooms_w_dwelling_units -office_buildings_office_space -office_buildings_reception_areas -office_buildings_telephone_data_entry -office_buildings_main_entry_lobbies -office_buildings_breakrooms -office_buildings_occupiable_storage_rooms -miscellaneous_spaces_bank_ vaults_safe_deposit -miscellaneous_spaces_computer -miscellaneous_spaces_pharmacy -miscellaneous_spaces_photo_studios -miscellaneous_spaces_shipping_receiving -miscellaneous_spaces_transportation_waiting -miscellaneous_spaces_warehouses -miscellaneous_spaces_banks_bank_lobbies -miscellaneous_spaces_freezer_refrigerated_spaces -miscellaneous_spaces_manufacturing_wo_hazardous_materials -miscellaneous_spaces_manufacturing_w_hazardous_materials -miscellaneous_spaces_sorting_packing_light_assembly -miscellaneous_spaces_telephone_closets -public_assembly_spaces_auditorium_seating_area -public_assembly_spaces_religious_workshop -public_assembly_spaces_courtrooms -public_assembly_spaces_legislative_chambers -public_assembly_spaces_libraries -public_assembly_spaces_lobbies -public_assembly_spaces_children_museums -public_assembly_spaces_museums_galleries -retail_sales -retail_mall_common_areas -retail_barbershop -retail_beauty_nail_salons -retail_pet_shops -retail_supermarket -retail_coin_operated_laundries -sports_entertainment_sports_arena -sports_entertainment_gym_stadium -sports_entertainment_spectator_areas -sports_entertainment_swimming -sports_entertainment_disco_dance_floors -sports_entertainment_health_club_aerobics_room -sports_entertainment_health_club_weight_rooms -sports_entertainment_bowling_alley -sports_entertainment_gambling_casinos -sports_entertainment_game_arcades -sports_entertainment_stages_studios -animal_facilities_animal_exam_room -animal_facilities_animal_imaging -animal_facilities_animal_operating_rooms -animal_facilities_animal_postoperative_recovery_room -animal_facilities_animal_preparation_rooms -animal_facilities_animal_procedure_room -animal_facilities_animal_surgery_scrub -animal_facilities_large_animal_holding_room -animal_facilities_necropsy -animal_facilities_small_animal_cage_room_static -animal_facilities_small_animal_cage_room_ventilated -outpatient_health_care_facilities_birthing_room -outpatient_health_care_facilities_class_1_imaging_rooms -outpatient_health_care_facilities_dental_operatory -outpatient_health_care_facilities_general_examination_room -outpatient_health_care_facilities_other_dental_treatment_areas -outpatient_health_care_facilities_physical_therapy_exercise_area -outpatient_health_care_facilities_physical_therapy_individual_room -outpatient_health_care_facilities_physical_therapeutic_pool_area -outpatient_health_care_facilities_prosthetics_orthotics_room -outpatient_health_care_facilities_psychiatric_consultation_room -outpatient_health_care_facilities_psychiatric_examination_room -outpatient_health_care_facilities_psychiatric_group_room -outpatient_health_care_facilities_psychiatric_seclusion_room -outpatient_health_care_facilities_speech_therapy_room -outpatient_health_care_facilities_urgent_care_examination_room -outpatient_health_care_facilities_urgent_care_observation_room -outpatient_health_care_facilities_urgent_care_treatment_room -outpatient_health_care_facilities_urgent_care_triage_room -transient_residential_common_corridors -transient_residential_dwelling_unit diff --git a/data/openstudio_standards_data/initial_data/system_requirement_economizer_90_1.csv b/data/openstudio_standards_data/initial_data/system_requirement_economizer_90_1.csv deleted file mode 100644 index 1405f86a9d..0000000000 --- a/data/openstudio_standards_data/initial_data/system_requirement_economizer_90_1.csv +++ /dev/null @@ -1,497 +0,0 @@ -template,climate_zone,data_center,capacity_limit,fixed_dry_bulb_high_limit_shutoff_temp,annotation -90.1-2004,ASHRAE 169-2006-1A,FALSE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-1A,TRUE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-1B,FALSE,,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-1B,TRUE,,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-2A,FALSE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-2A,TRUE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-2B,FALSE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-2B,TRUE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-3A,FALSE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-3A,TRUE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-3B,FALSE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-3B,TRUE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-3C,FALSE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-3C,TRUE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-4A,FALSE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-4A,TRUE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-4B,FALSE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-4B,TRUE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-4C,FALSE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-4C,TRUE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-5A,FALSE,135000,70,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-5A,TRUE,135000,70,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-5B,FALSE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-5B,TRUE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-5C,FALSE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-5C,TRUE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-6A,FALSE,135000,70,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-6A,TRUE,135000,70,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-6B,FALSE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-6B,TRUE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-7A,FALSE,135000,70,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-7A,TRUE,135000,70,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-7B,FALSE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-7B,TRUE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-8A,FALSE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-8A,TRUE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-8B,FALSE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-8B,TRUE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-1A,FALSE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-1A,TRUE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-1B,FALSE,,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-1B,TRUE,,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-2A,FALSE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-2A,TRUE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-2B,FALSE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-2B,TRUE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-3A,FALSE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-3A,TRUE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-3B,FALSE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-3B,TRUE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-3C,FALSE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-3C,TRUE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-4A,FALSE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-4A,TRUE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-4B,FALSE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-4B,TRUE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-4C,FALSE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-4C,TRUE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-5A,FALSE,135000,70,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-5A,TRUE,135000,70,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-5B,FALSE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-5B,TRUE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-5C,FALSE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-5C,TRUE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-6A,FALSE,135000,70,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-6A,TRUE,135000,70,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-6B,FALSE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-6B,TRUE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-7A,FALSE,135000,70,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-7A,TRUE,135000,70,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-7B,FALSE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-7B,TRUE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-8A,FALSE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-8A,TRUE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-8B,FALSE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-8B,TRUE,135000,75,90.1-2004 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-1A,FALSE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-1A,TRUE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-1B,FALSE,,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-1B,TRUE,,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-2A,FALSE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-2A,TRUE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-2B,FALSE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-2B,TRUE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-3A,FALSE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-3A,TRUE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-3B,FALSE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-3B,TRUE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-3C,FALSE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-3C,TRUE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-4A,FALSE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-4A,TRUE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-4B,FALSE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-4B,TRUE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-4C,FALSE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-4C,TRUE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-5A,FALSE,135000,70,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-5A,TRUE,135000,70,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-5B,FALSE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-5B,TRUE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-5C,FALSE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-5C,TRUE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-6A,FALSE,135000,70,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-6A,TRUE,135000,70,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-6B,FALSE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-6B,TRUE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-7A,FALSE,135000,70,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-7A,TRUE,135000,70,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-7B,FALSE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-7B,TRUE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-8A,FALSE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-8A,TRUE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-8B,FALSE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-8B,TRUE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-1A,FALSE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-1A,TRUE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-1B,FALSE,,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-1B,TRUE,,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-2A,FALSE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-2A,TRUE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-2B,FALSE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-2B,TRUE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-3A,FALSE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-3A,TRUE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-3B,FALSE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-3B,TRUE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-3C,FALSE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-3C,TRUE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-4A,FALSE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-4A,TRUE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-4B,FALSE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-4B,TRUE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-4C,FALSE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-4C,TRUE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-5A,FALSE,135000,70,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-5A,TRUE,135000,70,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-5B,FALSE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-5B,TRUE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-5C,FALSE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-5C,TRUE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-6A,FALSE,135000,70,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-6A,TRUE,135000,70,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-6B,FALSE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-6B,TRUE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-7A,FALSE,135000,70,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-7A,TRUE,135000,70,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-7B,FALSE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-7B,TRUE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-8A,FALSE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-8A,TRUE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-8B,FALSE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-8B,TRUE,135000,75,90.1-2007 Table 6.5.1 -90.1-2010,ASHRAE 169-2006-1A,TRUE,,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-1A,FALSE,,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-1B,TRUE,,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-1B,FALSE,,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-2A,TRUE,,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-2A,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-2B,TRUE,135000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-2B,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-3A,TRUE,,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-3A,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-3B,TRUE,65000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-3B,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-3C,TRUE,65000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-3C,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-4A,TRUE,,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-4A,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-4B,TRUE,65000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-4B,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-4C,TRUE,65000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-4C,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-5A,TRUE,135000,70,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-5A,FALSE,54000,70,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-5B,TRUE,65000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-5B,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-5C,TRUE,65000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-5C,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-6A,TRUE,135000,70,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-6A,FALSE,54000,70,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-6B,TRUE,65000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-6B,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-7A,TRUE,135000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-7A,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-7B,TRUE,135000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-7B,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-8A,TRUE,135000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-8A,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-8B,TRUE,135000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-8B,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-1A,TRUE,,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-1A,FALSE,,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-1B,TRUE,,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-1B,FALSE,,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-2A,TRUE,,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-2A,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-2B,TRUE,135000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-2B,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-3A,TRUE,,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-3A,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-3B,TRUE,65000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-3B,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-3C,TRUE,65000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-3C,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-4A,TRUE,,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-4A,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-4B,TRUE,65000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-4B,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-4C,TRUE,65000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-4C,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-5A,TRUE,135000,70,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-5A,FALSE,54000,70,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-5B,TRUE,65000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-5B,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-5C,TRUE,65000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-5C,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-6A,TRUE,135000,70,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-6A,FALSE,54000,70,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-6B,TRUE,65000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-6B,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-7A,TRUE,135000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-7A,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-7B,TRUE,135000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-7B,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-8A,TRUE,135000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-8A,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-8B,TRUE,135000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-8B,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2013,ASHRAE 169-2006-1A,TRUE,,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-1A,FALSE,,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-1B,TRUE,,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-1B,FALSE,,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-2A,TRUE,,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-2A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-2B,TRUE,135000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-2B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-3A,TRUE,,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-3A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-3B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-3B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-3C,TRUE,65000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-3C,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-4A,TRUE,,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-4A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-4B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-4B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-4C,TRUE,65000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-4C,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-5A,TRUE,135000,70,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-5A,FALSE,54000,70,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-5B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-5B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-5C,TRUE,65000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-5C,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-6A,TRUE,135000,70,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-6A,FALSE,54000,70,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-6B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-6B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-7A,TRUE,135000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-7A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-7B,TRUE,135000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-7B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-8A,TRUE,135000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-8A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-8B,TRUE,135000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-8B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-1A,TRUE,,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-1A,FALSE,,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-1B,TRUE,,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-1B,FALSE,,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-2A,TRUE,,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-2A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-2B,TRUE,135000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-2B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-3A,TRUE,,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-3A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-3B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-3B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-3C,TRUE,65000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-3C,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-4A,TRUE,,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-4A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-4B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-4B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-4C,TRUE,65000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-4C,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-5A,TRUE,135000,70,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-5A,FALSE,54000,70,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-5B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-5B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-5C,TRUE,65000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-5C,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-6A,TRUE,135000,70,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-6A,FALSE,54000,70,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-6B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-6B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-7A,TRUE,135000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-7A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-7B,TRUE,135000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-7B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-8A,TRUE,135000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-8A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-8B,TRUE,135000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-8B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2004,ASHRAE 169-2006-0A,FALSE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-0B,FALSE,,75,90.1-2004 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-0A,FALSE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-0B,FALSE,,75,90.1-2007 Table 6.5.1 -90.1-2010,ASHRAE 169-2006-0A,FALSE,,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-0B,FALSE,,75,90.1-2010 Table 6.5.1A -90.1-2013,ASHRAE 169-2006-0A,FALSE,,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-0B,FALSE,,75,90.1-2013 Table 6.5.1-1 -90.1-2004,ASHRAE 169-2013-0A,FALSE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-0B,FALSE,,75,90.1-2004 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-0A,FALSE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-0B,FALSE,,75,90.1-2007 Table 6.5.1 -90.1-2010,ASHRAE 169-2013-0A,FALSE,,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-0B,FALSE,,75,90.1-2010 Table 6.5.1A -90.1-2013,ASHRAE 169-2013-0A,FALSE,,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-0B,FALSE,,75,90.1-2013 Table 6.5.1-1 -90.1-2010,ASHRAE 169-2006-0A,TRUE,,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-0B,TRUE,,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-0A,TRUE,,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-0B,TRUE,,75,90.1-2010 Table 6.5.1B -90.1-2013,ASHRAE 169-2006-0A,TRUE,,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-0B,TRUE,,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-0A,TRUE,,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-0B,TRUE,,75,90.1-2013 Table 6.5.1-2 -90.1-2016,ASHRAE 169-2006-1A,TRUE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-1A,FALSE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-1B,TRUE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-1B,FALSE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-2A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-2A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-2B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-2B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-3A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-3A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-3B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-3B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-3C,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-3C,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-4A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-4A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-4B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-4B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-4C,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-4C,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-5A,TRUE,54000,70,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-5A,FALSE,54000,70,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-5B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-5B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-5C,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-5C,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-6A,TRUE,54000,70,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-6A,FALSE,54000,70,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-6B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-6B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-7A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-7A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-7B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-7B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-8A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-8A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-8B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-8B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-1A,TRUE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-1A,FALSE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-1B,TRUE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-1B,FALSE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-2A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-2A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-2B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-2B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-3A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-3A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-3B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-3B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-3C,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-3C,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-4A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-4A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-4B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-4B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-4C,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-4C,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-5A,TRUE,54000,70,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-5A,FALSE,54000,70,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-5B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-5B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-5C,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-5C,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-6A,TRUE,54000,70,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-6A,FALSE,54000,70,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-6B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-6B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-7A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-7A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-7B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-7B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-8A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-8A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-8B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-8B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-0A,FALSE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-0B,FALSE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-0A,FALSE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-0B,FALSE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-0A,TRUE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-0B,TRUE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-0A,TRUE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-0B,TRUE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-1A,TRUE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-1A,FALSE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-1B,TRUE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-1B,FALSE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-2A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-2A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-2B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-2B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-3A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-3A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-3B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-3B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-3C,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-3C,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-4A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-4A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-4B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-4B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-4C,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-4C,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-5A,TRUE,54000,70,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-5A,FALSE,54000,70,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-5B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-5B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-5C,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-5C,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-6A,TRUE,54000,70,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-6A,FALSE,54000,70,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-6B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-6B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-7A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-7A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-7B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-7B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-8A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-8A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-8B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-8B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-1A,TRUE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-1A,FALSE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-1B,TRUE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-1B,FALSE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-2A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-2A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-2B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-2B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-3A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-3A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-3B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-3B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-3C,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-3C,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-4A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-4A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-4B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-4B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-4C,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-4C,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-5A,TRUE,54000,70,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-5A,FALSE,54000,70,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-5B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-5B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-5C,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-5C,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-6A,TRUE,54000,70,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-6A,FALSE,54000,70,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-6B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-6B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-7A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-7A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-7B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-7B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-8A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-8A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-8B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-8B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-0A,FALSE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-0B,FALSE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-0A,FALSE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-0B,FALSE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-0A,TRUE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-0B,TRUE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-0A,TRUE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-0B,TRUE,,75,90.1-2019 Table 6.5.1.1.3 diff --git a/data/openstudio_standards_data/initial_data/system_requirement_energy_recovery_90_1.csv b/data/openstudio_standards_data/initial_data/system_requirement_energy_recovery_90_1.csv deleted file mode 100644 index a06d3844d7..0000000000 --- a/data/openstudio_standards_data/initial_data/system_requirement_energy_recovery_90_1.csv +++ /dev/null @@ -1,409 +0,0 @@ -template,climate_zone,under_8000_hours,nontransient_dwelling,percent_oa_0_to_10,percent_oa_10_to_20,percent_oa_20_to_30,percent_oa_30_to_40,percent_oa_40_to_50,percent_oa_50_to_60,percent_oa_60_to_70,percent_oa_70_to_80,percent_oa_greater_than_80,enthalpy_recovery_ratio_design_conditions,enthalpy_recovery_ratio,annotation -90.1-2010,ASHRAE 169-2006-1A,,,,,,5500,4500,3500,2000,1000,0,, -90.1-2010,ASHRAE 169-2006-1B,,,,,,,,26000,12000,5000,4000,, -90.1-2010,ASHRAE 169-2006-2A,,,,,,5500,4500,3500,2000,1000,0,, -90.1-2010,ASHRAE 169-2006-2B,,,,,,,,26000,12000,5000,4000,, -90.1-2010,ASHRAE 169-2006-3A,,,,,,5500,4500,3500,2000,1000,0,, -90.1-2010,ASHRAE 169-2006-3B,,,,,,,,,,5000,5000,, -90.1-2010,ASHRAE 169-2006-3C,,,,,,,,,,5000,5000,, -90.1-2010,ASHRAE 169-2006-4A,,,,,,5500,4500,3500,2000,1000,0,, -90.1-2010,ASHRAE 169-2006-4B,,,,,,,,,,5000,5000,, -90.1-2010,ASHRAE 169-2006-4C,,,,,,,,,,5000,5000,, -90.1-2010,ASHRAE 169-2006-5A,,,,,,5500,4500,3500,2000,1000,0,, -90.1-2010,ASHRAE 169-2006-5B,,,,,,,,,,5000,5000,, -90.1-2010,ASHRAE 169-2006-5C,,,,,,,,26000,12000,5000,4000,, -90.1-2010,ASHRAE 169-2006-6A,,,,,,5500,4500,3500,2000,1000,0,, -90.1-2010,ASHRAE 169-2006-6B,,,,,,11000,5500,4500,3500,2500,1500,, -90.1-2010,ASHRAE 169-2006-7A,,,,,,2500,1000,0,0,0,0,, -90.1-2010,ASHRAE 169-2006-7B,,,,,,2500,1000,0,0,0,0,, -90.1-2010,ASHRAE 169-2006-8A,,,,,,2500,1000,0,0,0,0,, -90.1-2010,ASHRAE 169-2006-8B,,,,,,2500,1000,0,0,0,0,, -90.1-2010,ASHRAE 169-2013-1A,,,,,,5500,4500,3500,2000,1000,0,, -90.1-2010,ASHRAE 169-2013-1B,,,,,,,,26000,12000,5000,4000,, -90.1-2010,ASHRAE 169-2013-2A,,,,,,5500,4500,3500,2000,1000,0,, -90.1-2010,ASHRAE 169-2013-2B,,,,,,,,26000,12000,5000,4000,, -90.1-2010,ASHRAE 169-2013-3A,,,,,,5500,4500,3500,2000,1000,0,, -90.1-2010,ASHRAE 169-2013-3B,,,,,,,,,,5000,5000,, -90.1-2010,ASHRAE 169-2013-3C,,,,,,,,,,5000,5000,, -90.1-2010,ASHRAE 169-2013-4A,,,,,,5500,4500,3500,2000,1000,0,, -90.1-2010,ASHRAE 169-2013-4B,,,,,,,,,,5000,5000,, -90.1-2010,ASHRAE 169-2013-4C,,,,,,,,,,5000,5000,, -90.1-2010,ASHRAE 169-2013-5A,,,,,,5500,4500,3500,2000,1000,0,, -90.1-2010,ASHRAE 169-2013-5B,,,,,,,,,,5000,5000,, -90.1-2010,ASHRAE 169-2013-5C,,,,,,,,26000,12000,5000,4000,, -90.1-2010,ASHRAE 169-2013-6A,,,,,,5500,4500,3500,2000,1000,0,, -90.1-2010,ASHRAE 169-2013-6B,,,,,,11000,5500,4500,3500,2500,1500,, -90.1-2010,ASHRAE 169-2013-7A,,,,,,2500,1000,0,0,0,0,, -90.1-2010,ASHRAE 169-2013-7B,,,,,,2500,1000,0,0,0,0,, -90.1-2010,ASHRAE 169-2013-8A,,,,,,2500,1000,0,0,0,0,, -90.1-2010,ASHRAE 169-2013-8B,,,,,,2500,1000,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-1A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, -90.1-2013,ASHRAE 169-2006-1A,FALSE,,,2500,2000,1000,500,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-1B,TRUE,,,,,,,26000,12000,5000,4000,, -90.1-2013,ASHRAE 169-2006-1B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, -90.1-2013,ASHRAE 169-2006-2A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, -90.1-2013,ASHRAE 169-2006-2A,FALSE,,,2500,2000,1000,500,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-2B,TRUE,,,,,,,26000,12000,5000,4000,, -90.1-2013,ASHRAE 169-2006-2B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, -90.1-2013,ASHRAE 169-2006-3A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, -90.1-2013,ASHRAE 169-2006-3A,FALSE,,,2500,2000,1000,500,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-3B,TRUE,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2006-3B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, -90.1-2013,ASHRAE 169-2006-3C,TRUE,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2006-3C,FALSE,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2006-4A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, -90.1-2013,ASHRAE 169-2006-4A,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-4B,TRUE,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2006-4B,FALSE,,,2500,2000,1000,500,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-4C,TRUE,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2006-4C,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, -90.1-2013,ASHRAE 169-2006-5A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, -90.1-2013,ASHRAE 169-2006-5A,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-5B,TRUE,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2006-5B,FALSE,,,2500,2000,1000,500,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-5C,TRUE,,,,,,,26000,12000,5000,4000,, -90.1-2013,ASHRAE 169-2006-5C,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, -90.1-2013,ASHRAE 169-2006-6A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, -90.1-2013,ASHRAE 169-2006-6A,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-6B,TRUE,,,28000,26500,11000,5500,4500,3500,2500,1500,, -90.1-2013,ASHRAE 169-2006-6B,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-7A,TRUE,,,4500,4000,2500,1000,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-7A,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-7B,TRUE,,,4500,4000,2500,1000,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-7B,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-8A,TRUE,,,4500,4000,2500,1000,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-8A,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-8B,TRUE,,,4500,4000,2500,1000,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-8B,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-1A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, -90.1-2013,ASHRAE 169-2013-1A,FALSE,,,2500,2000,1000,500,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-1B,TRUE,,,,,,,26000,12000,5000,4000,, -90.1-2013,ASHRAE 169-2013-1B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, -90.1-2013,ASHRAE 169-2013-2A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, -90.1-2013,ASHRAE 169-2013-2A,FALSE,,,2500,2000,1000,500,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-2B,TRUE,,,,,,,26000,12000,5000,4000,, -90.1-2013,ASHRAE 169-2013-2B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, -90.1-2013,ASHRAE 169-2013-3A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, -90.1-2013,ASHRAE 169-2013-3A,FALSE,,,2500,2000,1000,500,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-3B,TRUE,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2013-3B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, -90.1-2013,ASHRAE 169-2013-3C,TRUE,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2013-3C,FALSE,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2013-4A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, -90.1-2013,ASHRAE 169-2013-4A,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-4B,TRUE,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2013-4B,FALSE,,,2500,2000,1000,500,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-4C,TRUE,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2013-4C,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, -90.1-2013,ASHRAE 169-2013-5A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, -90.1-2013,ASHRAE 169-2013-5A,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-5B,TRUE,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2013-5B,FALSE,,,2500,2000,1000,500,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-5C,TRUE,,,,,,,26000,12000,5000,4000,, -90.1-2013,ASHRAE 169-2013-5C,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, -90.1-2013,ASHRAE 169-2013-6A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, -90.1-2013,ASHRAE 169-2013-6A,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-6B,TRUE,,,28000,26500,11000,5500,4500,3500,2500,1500,, -90.1-2013,ASHRAE 169-2013-6B,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-7A,TRUE,,,4500,4000,2500,1000,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-7A,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-7B,TRUE,,,4500,4000,2500,1000,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-7B,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-8A,TRUE,,,4500,4000,2500,1000,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-8A,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-8B,TRUE,,,4500,4000,2500,1000,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-8B,FALSE,,,0,0,0,0,0,0,0,0,, -90.1-2016,ASHRAE 169-2006-1A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-1A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-1B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-1B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-2A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-2A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-2B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-2B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-3A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-3A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-3B,TRUE,,,,,,,,,,,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-3B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-3C,TRUE,,,,,,,,,,,Heating,0.5 -90.1-2016,ASHRAE 169-2006-3C,FALSE,,,,,,,,,,,Heating,0.5 -90.1-2016,ASHRAE 169-2006-4A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-4A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-4B,TRUE,,,,,,,,,,,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-4B,TRUE,,,,,,,,,,,Heating,0.5 -90.1-2016,ASHRAE 169-2006-4B,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-4B,FALSE,,,2500,2000,1000,500,140,120,100,80,Heating,0.5 -90.1-2016,ASHRAE 169-2006-4C,TRUE,,,,,,,,,,,Heating,0.5 -90.1-2016,ASHRAE 169-2006-4C,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 -90.1-2016,ASHRAE 169-2006-5A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-5A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-5B,TRUE,,,,,,,,,,,Heating,0.5 -90.1-2016,ASHRAE 169-2006-5B,FALSE,,,2500,2000,1000,500,140,120,100,80,Heating,0.5 -90.1-2016,ASHRAE 169-2006-5C,TRUE,,,,,,,26000,12000,5000,4000,Heating,0.5 -90.1-2016,ASHRAE 169-2006-5C,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 -90.1-2016,ASHRAE 169-2006-6A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-6A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-6B,TRUE,,,28000,26500,11000,5500,4500,3500,2500,1500,Heating,0.5 -90.1-2016,ASHRAE 169-2006-6B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2016,ASHRAE 169-2006-7A,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2016,ASHRAE 169-2006-7A,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2016,ASHRAE 169-2006-7B,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2016,ASHRAE 169-2006-7B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2016,ASHRAE 169-2006-8A,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2016,ASHRAE 169-2006-8A,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2016,ASHRAE 169-2006-8B,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2016,ASHRAE 169-2006-8B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2016,ASHRAE 169-2013-1A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-1A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-1B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-1B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-2A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-2A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-2B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-2B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-3A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-3A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-3B,TRUE,,,,,,,,,,,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-3B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-3C,TRUE,,,,,,,,,,,Heating,0.5 -90.1-2016,ASHRAE 169-2013-3C,FALSE,,,,,,,,,,,Heating,0.5 -90.1-2016,ASHRAE 169-2013-4A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-4A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-4B,TRUE,,,,,,,,,,,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-4B,TRUE,,,,,,,,,,,Heating,0.5 -90.1-2016,ASHRAE 169-2013-4B,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-4B,FALSE,,,2500,2000,1000,500,140,120,100,80,Heating,0.5 -90.1-2016,ASHRAE 169-2013-4C,TRUE,,,,,,,,,,,Heating,0.5 -90.1-2016,ASHRAE 169-2013-4C,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 -90.1-2016,ASHRAE 169-2013-5A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-5A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-5B,TRUE,,,,,,,,,,,Heating,0.5 -90.1-2016,ASHRAE 169-2013-5B,FALSE,,,2500,2000,1000,500,140,120,100,80,Heating,0.5 -90.1-2016,ASHRAE 169-2013-5C,TRUE,,,,,,,26000,12000,5000,4000,Heating,0.5 -90.1-2016,ASHRAE 169-2013-5C,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 -90.1-2016,ASHRAE 169-2013-6A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-6A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-6B,TRUE,,,28000,26500,11000,5500,4500,3500,2500,1500,Heating,0.5 -90.1-2016,ASHRAE 169-2013-6B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2016,ASHRAE 169-2013-7A,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2016,ASHRAE 169-2013-7A,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2016,ASHRAE 169-2013-7B,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2016,ASHRAE 169-2013-7B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2016,ASHRAE 169-2013-8A,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2016,ASHRAE 169-2013-8A,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2016,ASHRAE 169-2013-8B,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2016,ASHRAE 169-2013-8B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2006-1A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-1A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-1A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-1A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-1B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-1B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-1B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-1B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-2A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-2A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-2A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-2A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-2B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-2B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-2B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-2B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-3A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-3A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-3A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 -90.1-2019,ASHRAE 169-2006-3A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-3A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-3A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5 -90.1-2019,ASHRAE 169-2006-3B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-3B,TRUE,FALSE,,,,,,,,,,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-3B,TRUE,FALSE,,,,,,,,,,Heating,0.5 -90.1-2019,ASHRAE 169-2006-3B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-3B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-3B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 -90.1-2019,ASHRAE 169-2006-3C,TRUE,TRUE,,,,,,,,,,, -90.1-2019,ASHRAE 169-2006-3C,TRUE,FALSE,,,,,,,,,,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-3C,TRUE,FALSE,,,,,,,,,,Heating,0.5 -90.1-2019,ASHRAE 169-2006-3C,FALSE,TRUE,,,,,,,,,,, -90.1-2019,ASHRAE 169-2006-3C,FALSE,FALSE,,,,,,,,,,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-3C,FALSE,FALSE,,,,,,,,,,Heating,0.5 -90.1-2019,ASHRAE 169-2006-4A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-4A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-4A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 -90.1-2019,ASHRAE 169-2006-4A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-4A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-4A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2006-4B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-4B,TRUE,FALSE,,,,,,,,,,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-4B,TRUE,FALSE,,,,,,,,,,Heating,0.5 -90.1-2019,ASHRAE 169-2006-4B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-4B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-4B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5 -90.1-2019,ASHRAE 169-2006-4C,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-4C,TRUE,FALSE,,,,,,,,,,Heating,0.5 -90.1-2019,ASHRAE 169-2006-4C,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-4C,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 -90.1-2019,ASHRAE 169-2006-5A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-5A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-5A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 -90.1-2019,ASHRAE 169-2006-5A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-5A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-5A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2006-5B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-5B,TRUE,FALSE,,,,,,,,,,Heating,0.5 -90.1-2019,ASHRAE 169-2006-5B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-5B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5 -90.1-2019,ASHRAE 169-2006-5C,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-5C,TRUE,FALSE,,,,,,26000,12000,5000,4000,Heating,0.5 -90.1-2019,ASHRAE 169-2006-5C,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-5C,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 -90.1-2019,ASHRAE 169-2006-6A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-6A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-6A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 -90.1-2019,ASHRAE 169-2006-6A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-6A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-6A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2006-6B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-6B,TRUE,FALSE,,28000,26500,11000,5500,4500,3500,2500,1500,Heating,0.5 -90.1-2019,ASHRAE 169-2006-6B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-6B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2006-7A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-7A,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2019,ASHRAE 169-2006-7A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-7A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2006-7B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-7B,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2019,ASHRAE 169-2006-7B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-7B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2006-8A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-8A,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2019,ASHRAE 169-2006-8A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-8A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2006-8B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-8B,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2019,ASHRAE 169-2006-8B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2006-8B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2013-1A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-1A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-1A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-1A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-1B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-1B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-1B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-1B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-2A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-2A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-2A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-2A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-2B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-2B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-2B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-2B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-3A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-3A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-3A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 -90.1-2019,ASHRAE 169-2013-3A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-3A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-3A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5 -90.1-2019,ASHRAE 169-2013-3B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-3B,TRUE,FALSE,,,,,,,,,,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-3B,TRUE,FALSE,,,,,,,,,,Heating,0.5 -90.1-2019,ASHRAE 169-2013-3B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-3B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-3B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 -90.1-2019,ASHRAE 169-2013-3C,TRUE,TRUE,,,,,,,,,,, -90.1-2019,ASHRAE 169-2013-3C,TRUE,FALSE,,,,,,,,,,Heating,0.5 -90.1-2019,ASHRAE 169-2013-3C,FALSE,TRUE,,,,,,,,,,, -90.1-2019,ASHRAE 169-2013-3C,FALSE,FALSE,,,,,,,,,,Heating,0.5 -90.1-2019,ASHRAE 169-2013-4A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-4A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-4A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 -90.1-2019,ASHRAE 169-2013-4A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-4A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-4A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2013-4B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-4B,TRUE,FALSE,,,,,,,,,,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-4B,TRUE,FALSE,,,,,,,,,,Heating,0.5 -90.1-2019,ASHRAE 169-2013-4B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-4B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-4B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5 -90.1-2019,ASHRAE 169-2013-4C,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-4C,TRUE,FALSE,,,,,,,,,,Heating,0.5 -90.1-2019,ASHRAE 169-2013-4C,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-4C,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 -90.1-2019,ASHRAE 169-2013-5A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-5A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-5A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 -90.1-2019,ASHRAE 169-2013-5A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-5A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-5A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2013-5B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-5B,TRUE,FALSE,,,,,,,,,,Heating,0.5 -90.1-2019,ASHRAE 169-2013-5B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-5B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5 -90.1-2019,ASHRAE 169-2013-5C,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-5C,TRUE,FALSE,,,,,,26000,12000,5000,4000,Heating,0.5 -90.1-2019,ASHRAE 169-2013-5C,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-5C,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5 -90.1-2019,ASHRAE 169-2013-6A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-6A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-6A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5 -90.1-2019,ASHRAE 169-2013-6A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-6A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-6A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2013-6B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-6B,TRUE,FALSE,,28000,26500,11000,5500,4500,3500,2500,1500,Heating,0.5 -90.1-2019,ASHRAE 169-2013-6B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-6B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2013-7A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-7A,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2019,ASHRAE 169-2013-7A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-7A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2013-7B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-7B,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2019,ASHRAE 169-2013-7B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-7B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2013-8A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-8A,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2019,ASHRAE 169-2013-8A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-8A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2019,ASHRAE 169-2013-8B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-8B,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5 -90.1-2019,ASHRAE 169-2013-8B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6 -90.1-2019,ASHRAE 169-2013-8B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5 -90.1-2010,ASHRAE 169-2006-0A,,,,,,5500,4500,3500,2000,1000,0,, -90.1-2010,ASHRAE 169-2006-0B,,,,,,,,26000,12000,5000,4000,, -90.1-2010,ASHRAE 169-2013-0A,,,,,,5500,4500,3500,2000,1000,0,, -90.1-2010,ASHRAE 169-2013-0B,,,,,,,,26000,12000,5000,4000,, -90.1-2013,ASHRAE 169-2006-0A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, -90.1-2013,ASHRAE 169-2006-0A,FALSE,,,2500,2000,1000,500,0,0,0,0,, -90.1-2013,ASHRAE 169-2006-0B,TRUE,,,,,,,26000,12000,5000,4000,, -90.1-2013,ASHRAE 169-2006-0B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, -90.1-2013,ASHRAE 169-2013-0A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,, -90.1-2013,ASHRAE 169-2013-0A,FALSE,,,2500,2000,1000,500,0,0,0,0,, -90.1-2013,ASHRAE 169-2013-0B,TRUE,,,,,,,26000,12000,5000,4000,, -90.1-2013,ASHRAE 169-2013-0B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,, -90.1-2016,ASHRAE 169-2006-0A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-0A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-0B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5 -90.1-2016,ASHRAE 169-2006-0B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-0A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-0A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-0B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5 -90.1-2016,ASHRAE 169-2013-0B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-0A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-0A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-0A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-0A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-0B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-0B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-0B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2006-0B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-0A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-0A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-0A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-0A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-0B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-0B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-0B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5 -90.1-2019,ASHRAE 169-2013-0B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5 diff --git a/data/openstudio_standards_data/initial_data/vent_space_tag.json b/data/openstudio_standards_data/initial_data/vent_space_tag.json deleted file mode 100644 index bc1269a0ba..0000000000 --- a/data/openstudio_standards_data/initial_data/vent_space_tag.json +++ /dev/null @@ -1,332 +0,0 @@ -[ - { - "vent_space_tag": "correctional_facilities_cell" - }, - { - "vent_space_tag": "correctional_facilities_dayroom" - }, - { - "vent_space_tag": "correctional_facilities_guard_stations" - }, - { - "vent_space_tag": "correctional_facilities_booking_waiting" - }, - { - "vent_space_tag": "educational_facilities_daycare" - }, - { - "vent_space_tag": "educational_facilities_classroom_young" - }, - { - "vent_space_tag": "educational_facilities_classroom_old" - }, - { - "vent_space_tag": "educational_facilities_lecture_classroom" - }, - { - "vent_space_tag": "educational_facilities_lecture_hall" - }, - { - "vent_space_tag": "educational_facilities_art_classroom" - }, - { - "vent_space_tag": "educational_facilities_science_laboratories" - }, - { - "vent_space_tag": "educational_facilities_wood_metal_shop" - }, - { - "vent_space_tag": "educational_facilities_computer_lab" - }, - { - "vent_space_tag": "educational_facilities_media_center" - }, - { - "vent_space_tag": "educational_facilities_music_theater_dance" - }, - { - "vent_space_tag": "educational_facilities_multiuse_assembly" - }, - { - "vent_space_tag": "educational_facilities_daycare_sickroom" - }, - { - "vent_space_tag": "educational_facilities_libraries" - }, - { - "vent_space_tag": "educational_facilities_university_college_laboratories" - }, - { - "vent_space_tag": "food_beverage_service_restaurant_dining_rooms" - }, - { - "vent_space_tag": "food_beverage_service_cafeteria_fast_food_dining" - }, - { - "vent_space_tag": "food_beverage_service_bars_cocktail_lounges" - }, - { - "vent_space_tag": "food_beverage_service_kitchen" - }, - { - "vent_space_tag": "general_conference_meeting" - }, - { - "vent_space_tag": "general_conference_corridors" - }, - { - "vent_space_tag": "general_conference_storage_rooms" - }, - { - "vent_space_tag": "general_break_rooms" - }, - { - "vent_space_tag": "general_coffee_stations" - }, - { - "vent_space_tag": "hotels_motels_resorts_dormitories_bedroom_living_room" - }, - { - "vent_space_tag": "hotels_motels_resorts_dormitories_barracks_sleeping_areas" - }, - { - "vent_space_tag": "hotels_motels_resorts_dormitories_lobbies_prefunction" - }, - { - "vent_space_tag": "hotels_motels_resorts_dormitories_multi_purpose_assembly" - }, - { - "vent_space_tag": "hotels_motels_resorts_dormitories_laundry_rooms" - }, - { - "vent_space_tag": "hotels_motels_resorts_dormitories_laundry_rooms_w_dwelling_units" - }, - { - "vent_space_tag": "office_buildings_office_space" - }, - { - "vent_space_tag": "office_buildings_reception_areas" - }, - { - "vent_space_tag": "office_buildings_telephone_data_entry" - }, - { - "vent_space_tag": "office_buildings_main_entry_lobbies" - }, - { - "vent_space_tag": "office_buildings_breakrooms" - }, - { - "vent_space_tag": "office_buildings_occupiable_storage_rooms" - }, - { - "vent_space_tag": "miscellaneous_spaces_bank_ vaults_safe_deposit" - }, - { - "vent_space_tag": "miscellaneous_spaces_computer" - }, - { - "vent_space_tag": "miscellaneous_spaces_pharmacy" - }, - { - "vent_space_tag": "miscellaneous_spaces_photo_studios" - }, - { - "vent_space_tag": "miscellaneous_spaces_shipping_receiving" - }, - { - "vent_space_tag": "miscellaneous_spaces_transportation_waiting" - }, - { - "vent_space_tag": "miscellaneous_spaces_warehouses" - }, - { - "vent_space_tag": "miscellaneous_spaces_banks_bank_lobbies" - }, - { - "vent_space_tag": "miscellaneous_spaces_freezer_refrigerated_spaces" - }, - { - "vent_space_tag": "miscellaneous_spaces_manufacturing_wo_hazardous_materials" - }, - { - "vent_space_tag": "miscellaneous_spaces_manufacturing_w_hazardous_materials" - }, - { - "vent_space_tag": "miscellaneous_spaces_sorting_packing_light_assembly" - }, - { - "vent_space_tag": "miscellaneous_spaces_telephone_closets" - }, - { - "vent_space_tag": "public_assembly_spaces_auditorium_seating_area" - }, - { - "vent_space_tag": "public_assembly_spaces_religious_workshop" - }, - { - "vent_space_tag": "public_assembly_spaces_courtrooms" - }, - { - "vent_space_tag": "public_assembly_spaces_legislative_chambers" - }, - { - "vent_space_tag": "public_assembly_spaces_libraries" - }, - { - "vent_space_tag": "public_assembly_spaces_lobbies" - }, - { - "vent_space_tag": "public_assembly_spaces_children_museums" - }, - { - "vent_space_tag": "public_assembly_spaces_museums_galleries" - }, - { - "vent_space_tag": "retail_sales" - }, - { - "vent_space_tag": "retail_mall_common_areas" - }, - { - "vent_space_tag": "retail_barbershop" - }, - { - "vent_space_tag": "retail_beauty_nail_salons" - }, - { - "vent_space_tag": "retail_pet_shops" - }, - { - "vent_space_tag": "retail_supermarket" - }, - { - "vent_space_tag": "retail_coin_operated_laundries" - }, - { - "vent_space_tag": "sports_entertainment_sports_arena" - }, - { - "vent_space_tag": "sports_entertainment_gym_stadium" - }, - { - "vent_space_tag": "sports_entertainment_spectator_areas" - }, - { - "vent_space_tag": "sports_entertainment_swimming" - }, - { - "vent_space_tag": "sports_entertainment_disco_dance_floors" - }, - { - "vent_space_tag": "sports_entertainment_health_club_aerobics_room" - }, - { - "vent_space_tag": "sports_entertainment_health_club_weight_rooms" - }, - { - "vent_space_tag": "sports_entertainment_bowling_alley" - }, - { - "vent_space_tag": "sports_entertainment_gambling_casinos" - }, - { - "vent_space_tag": "sports_entertainment_game_arcades" - }, - { - "vent_space_tag": "sports_entertainment_stages_studios" - }, - { - "vent_space_tag": "animal_facilities_animal_exam_room" - }, - { - "vent_space_tag": "animal_facilities_animal_imaging" - }, - { - "vent_space_tag": "animal_facilities_animal_operating_rooms" - }, - { - "vent_space_tag": "animal_facilities_animal_postoperative_recovery_room" - }, - { - "vent_space_tag": "animal_facilities_animal_preparation_rooms" - }, - { - "vent_space_tag": "animal_facilities_animal_procedure_room" - }, - { - "vent_space_tag": "animal_facilities_animal_surgery_scrub" - }, - { - "vent_space_tag": "animal_facilities_large_animal_holding_room" - }, - { - "vent_space_tag": "animal_facilities_necropsy" - }, - { - "vent_space_tag": "animal_facilities_small_animal_cage_room_static" - }, - { - "vent_space_tag": "animal_facilities_small_animal_cage_room_ventilated" - }, - { - "vent_space_tag": "outpatient_health_care_facilities_birthing_room" - }, - { - "vent_space_tag": "outpatient_health_care_facilities_class_1_imaging_rooms" - }, - { - "vent_space_tag": "outpatient_health_care_facilities_dental_operatory" - }, - { - "vent_space_tag": "outpatient_health_care_facilities_general_examination_room" - }, - { - "vent_space_tag": "outpatient_health_care_facilities_other_dental_treatment_areas" - }, - { - "vent_space_tag": "outpatient_health_care_facilities_physical_therapy_exercise_area" - }, - { - "vent_space_tag": "outpatient_health_care_facilities_physical_therapy_individual_room" - }, - { - "vent_space_tag": "outpatient_health_care_facilities_physical_therapeutic_pool_area" - }, - { - "vent_space_tag": "outpatient_health_care_facilities_prosthetics_orthotics_room" - }, - { - "vent_space_tag": "outpatient_health_care_facilities_psychiatric_consultation_room" - }, - { - "vent_space_tag": "outpatient_health_care_facilities_psychiatric_examination_room" - }, - { - "vent_space_tag": "outpatient_health_care_facilities_psychiatric_group_room" - }, - { - "vent_space_tag": "outpatient_health_care_facilities_psychiatric_seclusion_room" - }, - { - "vent_space_tag": "outpatient_health_care_facilities_speech_therapy_room" - }, - { - "vent_space_tag": "outpatient_health_care_facilities_urgent_care_examination_room" - }, - { - "vent_space_tag": "outpatient_health_care_facilities_urgent_care_observation_room" - }, - { - "vent_space_tag": "outpatient_health_care_facilities_urgent_care_treatment_room" - }, - { - "vent_space_tag": "outpatient_health_care_facilities_urgent_care_triage_room" - }, - { - "vent_space_tag": "transient_residential_common_corridors" - }, - { - "vent_space_tag": "transient_residential_dwelling_unit" - } -] \ No newline at end of file diff --git a/data/openstudio_standards_data/initial_data/vent_subspaces.json b/data/openstudio_standards_data/initial_data/vent_subspaces.json deleted file mode 100644 index 2798bc1aa6..0000000000 --- a/data/openstudio_standards_data/initial_data/vent_subspaces.json +++ /dev/null @@ -1,1040 +0,0 @@ -[ - { - "id": 1, - "ventilation_type_name": "correctional_facilities_cell", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 13 - }, - { - "id": 2, - "ventilation_type_name": "correctional_facilities_dayroom", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 14 - }, - { - "id": 3, - "ventilation_type_name": "correctional_facilities_guard_stations", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 15 - }, - { - "id": 4, - "ventilation_type_name": "correctional_facilities_booking_waiting", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 12 - }, - { - "id": 5, - "ventilation_type_name": "educational_facilities_daycare", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 21 - }, - { - "id": 6, - "ventilation_type_name": "educational_facilities_classroom_young", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 17 - }, - { - "id": 7, - "ventilation_type_name": "educational_facilities_classroom_old", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 18 - }, - { - "id": 8, - "ventilation_type_name": "educational_facilities_lecture_classroom", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 22 - }, - { - "id": 9, - "ventilation_type_name": "educational_facilities_lecture_hall", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 23 - }, - { - "id": 10, - "ventilation_type_name": "educational_facilities_art_classroom", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 16 - }, - { - "id": 11, - "ventilation_type_name": "educational_facilities_science_laboratories", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 28 - }, - { - "id": 12, - "ventilation_type_name": "educational_facilities_wood_metal_shop", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 30 - }, - { - "id": 13, - "ventilation_type_name": "educational_facilities_computer_lab", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 19 - }, - { - "id": 14, - "ventilation_type_name": "educational_facilities_media_center", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 25 - }, - { - "id": 15, - "ventilation_type_name": "educational_facilities_music_theater_dance", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 27 - }, - { - "id": 16, - "ventilation_type_name": "educational_facilities_multiuse_assembly", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 26 - }, - { - "id": 17, - "ventilation_type_name": "educational_facilities_daycare_sickroom", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 20 - }, - { - "id": 18, - "ventilation_type_name": "educational_facilities_libraries", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 24 - }, - { - "id": 19, - "ventilation_type_name": "educational_facilities_university_college_laboratories", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 29 - }, - { - "id": 20, - "ventilation_type_name": "food_beverage_service_restaurant_dining_rooms", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 34 - }, - { - "id": 21, - "ventilation_type_name": "food_beverage_service_cafeteria_fast_food_dining", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 32 - }, - { - "id": 22, - "ventilation_type_name": "food_beverage_service_bars_cocktail_lounges", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 31 - }, - { - "id": 23, - "ventilation_type_name": "food_beverage_service_kitchen", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 33 - }, - { - "id": 24, - "ventilation_type_name": "general_conference_meeting", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 37 - }, - { - "id": 25, - "ventilation_type_name": "general_conference_corridors", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 38 - }, - { - "id": 26, - "ventilation_type_name": "general_conference_storage_rooms", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 39 - }, - { - "id": 27, - "ventilation_type_name": "general_break_rooms", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 35 - }, - { - "id": 28, - "ventilation_type_name": "general_coffee_stations", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 36 - }, - { - "id": 29, - "ventilation_type_name": "hotels_motels_resorts_dormitories_bedroom_living_room", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 41 - }, - { - "id": 30, - "ventilation_type_name": "hotels_motels_resorts_dormitories_barracks_sleeping_areas", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 40 - }, - { - "id": 31, - "ventilation_type_name": "hotels_motels_resorts_dormitories_lobbies_prefunction", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 44 - }, - { - "id": 32, - "ventilation_type_name": "hotels_motels_resorts_dormitories_multi_purpose_assembly", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 45 - }, - { - "id": 33, - "ventilation_type_name": "hotels_motels_resorts_dormitories_laundry_rooms", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 42 - }, - { - "id": 34, - "ventilation_type_name": "hotels_motels_resorts_dormitories_laundry_rooms_w_dwelling_units", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 43 - }, - { - "id": 35, - "ventilation_type_name": "office_buildings_office_space", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 62 - }, - { - "id": 36, - "ventilation_type_name": "office_buildings_reception_areas", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 63 - }, - { - "id": 37, - "ventilation_type_name": "office_buildings_telephone_data_entry", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 64 - }, - { - "id": 38, - "ventilation_type_name": "office_buildings_main_entry_lobbies", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 60 - }, - { - "id": 39, - "ventilation_type_name": "office_buildings_breakrooms", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 59 - }, - { - "id": 40, - "ventilation_type_name": "office_buildings_occupiable_storage_rooms", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 61 - }, - { - "id": 41, - "ventilation_type_name": "miscellaneous_spaces_bank_ vaults_safe_deposit", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 47 - }, - { - "id": 42, - "ventilation_type_name": "miscellaneous_spaces_computer", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 48 - }, - { - "id": 43, - "ventilation_type_name": "miscellaneous_spaces_pharmacy", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 52 - }, - { - "id": 44, - "ventilation_type_name": "miscellaneous_spaces_photo_studios", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 53 - }, - { - "id": 45, - "ventilation_type_name": "miscellaneous_spaces_shipping_receiving", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 54 - }, - { - "id": 46, - "ventilation_type_name": "miscellaneous_spaces_transportation_waiting", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 57 - }, - { - "id": 47, - "ventilation_type_name": "miscellaneous_spaces_warehouses", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 58 - }, - { - "id": 48, - "ventilation_type_name": "miscellaneous_spaces_banks_bank_lobbies", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 46 - }, - { - "id": 49, - "ventilation_type_name": "miscellaneous_spaces_freezer_refrigerated_spaces", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 49 - }, - { - "id": 50, - "ventilation_type_name": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 50 - }, - { - "id": 51, - "ventilation_type_name": "miscellaneous_spaces_manufacturing_w_hazardous_materials", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 51 - }, - { - "id": 52, - "ventilation_type_name": "miscellaneous_spaces_sorting_packing_light_assembly", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 55 - }, - { - "id": 53, - "ventilation_type_name": "miscellaneous_spaces_telephone_closets", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 56 - }, - { - "id": 54, - "ventilation_type_name": "public_assembly_spaces_auditorium_seating_area", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 83 - }, - { - "id": 55, - "ventilation_type_name": "public_assembly_spaces_religious_workshop", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 90 - }, - { - "id": 56, - "ventilation_type_name": "public_assembly_spaces_courtrooms", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 84 - }, - { - "id": 57, - "ventilation_type_name": "public_assembly_spaces_legislative_chambers", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 85 - }, - { - "id": 58, - "ventilation_type_name": "public_assembly_spaces_libraries", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 86 - }, - { - "id": 59, - "ventilation_type_name": "public_assembly_spaces_lobbies", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 87 - }, - { - "id": 60, - "ventilation_type_name": "public_assembly_spaces_children_museums", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 88 - }, - { - "id": 61, - "ventilation_type_name": "public_assembly_spaces_museums_galleries", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 89 - }, - { - "id": 62, - "ventilation_type_name": "retail_sales", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 91 - }, - { - "id": 63, - "ventilation_type_name": "retail_mall_common_areas", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 95 - }, - { - "id": 64, - "ventilation_type_name": "retail_barbershop", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 92 - }, - { - "id": 65, - "ventilation_type_name": "retail_beauty_nail_salons", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 93 - }, - { - "id": 66, - "ventilation_type_name": "retail_pet_shops", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 96 - }, - { - "id": 67, - "ventilation_type_name": "retail_supermarket", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 97 - }, - { - "id": 68, - "ventilation_type_name": "retail_coin_operated_laundries", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 94 - }, - { - "id": 69, - "ventilation_type_name": "sports_entertainment_sports_arena", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 102 - }, - { - "id": 70, - "ventilation_type_name": "sports_entertainment_gym_stadium", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 102 - }, - { - "id": 71, - "ventilation_type_name": "sports_entertainment_spectator_areas", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 105 - }, - { - "id": 72, - "ventilation_type_name": "sports_entertainment_swimming", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 107 - }, - { - "id": 73, - "ventilation_type_name": "sports_entertainment_disco_dance_floors", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 99 - }, - { - "id": 74, - "ventilation_type_name": "sports_entertainment_health_club_aerobics_room", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 103 - }, - { - "id": 75, - "ventilation_type_name": "sports_entertainment_health_club_weight_rooms", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 104 - }, - { - "id": 76, - "ventilation_type_name": "sports_entertainment_bowling_alley", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 98 - }, - { - "id": 77, - "ventilation_type_name": "sports_entertainment_gambling_casinos", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 100 - }, - { - "id": 78, - "ventilation_type_name": "sports_entertainment_game_arcades", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 101 - }, - { - "id": 79, - "ventilation_type_name": "sports_entertainment_stages_studios", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 106 - }, - { - "id": 80, - "ventilation_type_name": "animal_facilities_animal_exam_room", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 1 - }, - { - "id": 81, - "ventilation_type_name": "animal_facilities_animal_imaging", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 2 - }, - { - "id": 82, - "ventilation_type_name": "animal_facilities_animal_operating_rooms", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 3 - }, - { - "id": 83, - "ventilation_type_name": "animal_facilities_animal_postoperative_recovery_room", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 4 - }, - { - "id": 84, - "ventilation_type_name": "animal_facilities_animal_preparation_rooms", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 5 - }, - { - "id": 85, - "ventilation_type_name": "animal_facilities_animal_procedure_room", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 6 - }, - { - "id": 86, - "ventilation_type_name": "animal_facilities_animal_surgery_scrub", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 7 - }, - { - "id": 87, - "ventilation_type_name": "animal_facilities_large_animal_holding_room", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 8 - }, - { - "id": 88, - "ventilation_type_name": "animal_facilities_necropsy", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 9 - }, - { - "id": 89, - "ventilation_type_name": "animal_facilities_small_animal_cage_room_static", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 10 - }, - { - "id": 90, - "ventilation_type_name": "animal_facilities_small_animal_cage_room_ventilated", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 11 - }, - { - "id": 91, - "ventilation_type_name": "outpatient_health_care_facilities_birthing_room", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 65 - }, - { - "id": 92, - "ventilation_type_name": "outpatient_health_care_facilities_class_1_imaging_rooms", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 66 - }, - { - "id": 93, - "ventilation_type_name": "outpatient_health_care_facilities_dental_operatory", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 67 - }, - { - "id": 94, - "ventilation_type_name": "outpatient_health_care_facilities_general_examination_room", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 68 - }, - { - "id": 95, - "ventilation_type_name": "outpatient_health_care_facilities_other_dental_treatment_areas", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 69 - }, - { - "id": 96, - "ventilation_type_name": "outpatient_health_care_facilities_physical_therapy_exercise_area", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 70 - }, - { - "id": 97, - "ventilation_type_name": "outpatient_health_care_facilities_physical_therapy_individual_room", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 71 - }, - { - "id": 98, - "ventilation_type_name": "outpatient_health_care_facilities_physical_therapeutic_pool_area", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 72 - }, - { - "id": 99, - "ventilation_type_name": "outpatient_health_care_facilities_prosthetics_orthotics_room", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 73 - }, - { - "id": 100, - "ventilation_type_name": "outpatient_health_care_facilities_psychiatric_consultation_room", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 74 - }, - { - "id": 101, - "ventilation_type_name": "outpatient_health_care_facilities_psychiatric_examination_room", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 75 - }, - { - "id": 102, - "ventilation_type_name": "outpatient_health_care_facilities_psychiatric_group_room", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 76 - }, - { - "id": 103, - "ventilation_type_name": "outpatient_health_care_facilities_psychiatric_seclusion_room", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 77 - }, - { - "id": 104, - "ventilation_type_name": "outpatient_health_care_facilities_speech_therapy_room", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 78 - }, - { - "id": 105, - "ventilation_type_name": "outpatient_health_care_facilities_urgent_care_examination_room", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 79 - }, - { - "id": 106, - "ventilation_type_name": "outpatient_health_care_facilities_urgent_care_observation_room", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 80 - }, - { - "id": 107, - "ventilation_type_name": "outpatient_health_care_facilities_urgent_care_treatment_room", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 81 - }, - { - "id": 108, - "ventilation_type_name": "outpatient_health_care_facilities_urgent_care_triage_room", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 82 - }, - { - "id": 109, - "ventilation_type_name": "transient_residential_common_corridors", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 108 - }, - { - "id": 110, - "ventilation_type_name": "transient_residential_dwelling_unit", - "ventilation_table": "vent_def_62_1_2019", - "vent_621_id": 109 - }, - { - "id": 111, - "ventilation_type_name": "correctional_facilities_cell", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 1 - }, - { - "id": 112, - "ventilation_type_name": "correctional_facilities_dayroom", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 2 - }, - { - "id": 113, - "ventilation_type_name": "correctional_facilities_guard_stations", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 3 - }, - { - "id": 114, - "ventilation_type_name": "correctional_facilities_booking_waiting", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 4 - }, - { - "id": 115, - "ventilation_type_name": "educational_facilities_daycare", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 5 - }, - { - "id": 116, - "ventilation_type_name": "educational_facilities_classroom_young", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 6 - }, - { - "id": 117, - "ventilation_type_name": "educational_facilities_classroom_old", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 7 - }, - { - "id": 118, - "ventilation_type_name": "educational_facilities_lecture_classroom", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 8 - }, - { - "id": 119, - "ventilation_type_name": "educational_facilities_lecture_hall", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 9 - }, - { - "id": 120, - "ventilation_type_name": "educational_facilities_art_classroom", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 10 - }, - { - "id": 121, - "ventilation_type_name": "educational_facilities_science_laboratories", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 11 - }, - { - "id": 122, - "ventilation_type_name": "educational_facilities_wood_metal_shop", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 12 - }, - { - "id": 123, - "ventilation_type_name": "educational_facilities_computer_lab", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 13 - }, - { - "id": 124, - "ventilation_type_name": "educational_facilities_media_center", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 14 - }, - { - "id": 125, - "ventilation_type_name": "educational_facilities_music_theater_dance", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 15 - }, - { - "id": 126, - "ventilation_type_name": "educational_facilities_multiuse_assembly", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 16 - }, - { - "id": 127, - "ventilation_type_name": "food_beverage_service_restaurant_dining_rooms", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 17 - }, - { - "id": 128, - "ventilation_type_name": "food_beverage_service_cafeteria_fast_food_dining", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 18 - }, - { - "id": 129, - "ventilation_type_name": "food_beverage_service_bars_cocktail_lounges", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 19 - }, - { - "id": 130, - "ventilation_type_name": "general_conference_meeting", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 20 - }, - { - "id": 131, - "ventilation_type_name": "general_conference_corridors", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 21 - }, - { - "id": 132, - "ventilation_type_name": "general_conference_storage_rooms", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 22 - }, - { - "id": 133, - "ventilation_type_name": "hotels_motels_resorts_dormitories_bedroom_living_room", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 23 - }, - { - "id": 134, - "ventilation_type_name": "hotels_motels_resorts_dormitories_barracks_sleeping_areas", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 24 - }, - { - "id": 135, - "ventilation_type_name": "hotels_motels_resorts_dormitories_lobbies_prefunction", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 25 - }, - { - "id": 136, - "ventilation_type_name": "hotels_motels_resorts_dormitories_multi_purpose_assembly", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 26 - }, - { - "id": 137, - "ventilation_type_name": "office_buildings_office_space", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 27 - }, - { - "id": 138, - "ventilation_type_name": "office_buildings_reception_areas", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 28 - }, - { - "id": 139, - "ventilation_type_name": "office_buildings_telephone_data_entry", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 29 - }, - { - "id": 140, - "ventilation_type_name": "office_buildings_main_entry_lobbies", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 30 - }, - { - "id": 141, - "ventilation_type_name": "miscellaneous_spaces_bank_ vaults_safe_deposit", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 31 - }, - { - "id": 142, - "ventilation_type_name": "miscellaneous_spaces_computer", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 32 - }, - { - "id": 143, - "ventilation_type_name": "miscellaneous_spaces_pharmacy", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 33 - }, - { - "id": 144, - "ventilation_type_name": "miscellaneous_spaces_photo_studios", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 34 - }, - { - "id": 145, - "ventilation_type_name": "miscellaneous_spaces_shipping_receiving", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 35 - }, - { - "id": 146, - "ventilation_type_name": "miscellaneous_spaces_transportation_waiting", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 36 - }, - { - "id": 147, - "ventilation_type_name": "miscellaneous_spaces_warehouses", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 37 - }, - { - "id": 148, - "ventilation_type_name": "public_assembly_spaces_auditorium_seating_area", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 38 - }, - { - "id": 149, - "ventilation_type_name": "public_assembly_spaces_religious_workshop", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 39 - }, - { - "id": 150, - "ventilation_type_name": "public_assembly_spaces_courtrooms", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 40 - }, - { - "id": 151, - "ventilation_type_name": "public_assembly_spaces_legislative_chambers", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 41 - }, - { - "id": 152, - "ventilation_type_name": "public_assembly_spaces_libraries", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 42 - }, - { - "id": 153, - "ventilation_type_name": "public_assembly_spaces_lobbies", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 43 - }, - { - "id": 154, - "ventilation_type_name": "public_assembly_spaces_children_museums", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 44 - }, - { - "id": 155, - "ventilation_type_name": "public_assembly_spaces_museums_galleries", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 45 - }, - { - "id": 156, - "ventilation_type_name": "retail_sales", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 46 - }, - { - "id": 157, - "ventilation_type_name": "retail_mall_common_areas", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 47 - }, - { - "id": 158, - "ventilation_type_name": "retail_barbershop", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 48 - }, - { - "id": 159, - "ventilation_type_name": "retail_beauty_nail_salons", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 49 - }, - { - "id": 160, - "ventilation_type_name": "retail_pet_shops", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 50 - }, - { - "id": 161, - "ventilation_type_name": "retail_supermarket", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 51 - }, - { - "id": 162, - "ventilation_type_name": "retail_coin_operated_laundries", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 52 - }, - { - "id": 163, - "ventilation_type_name": "sports_entertainment_sports_arena", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 53 - }, - { - "id": 164, - "ventilation_type_name": "sports_entertainment_gym_stadium", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 54 - }, - { - "id": 165, - "ventilation_type_name": "sports_entertainment_spectator_areas", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 55 - }, - { - "id": 166, - "ventilation_type_name": "sports_entertainment_swimming", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 56 - }, - { - "id": 167, - "ventilation_type_name": "sports_entertainment_disco_dance_floors", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 57 - }, - { - "id": 168, - "ventilation_type_name": "sports_entertainment_health_club_aerobics_room", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 58 - }, - { - "id": 169, - "ventilation_type_name": "sports_entertainment_health_club_weight_rooms", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 59 - }, - { - "id": 170, - "ventilation_type_name": "sports_entertainment_bowling_alley", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 60 - }, - { - "id": 171, - "ventilation_type_name": "sports_entertainment_gambling_casinos", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 61 - }, - { - "id": 172, - "ventilation_type_name": "sports_entertainment_game_arcades", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 62 - }, - { - "id": 173, - "ventilation_type_name": "sports_entertainment_stages_studios", - "ventilation_table": "vent_def_62_1_2004", - "vent_621_id": 63 - } -] \ No newline at end of file From 6847ad0a3a7c77a5fae51f5449a1d85fbb9fe3f3 Mon Sep 17 00:00:00 2001 From: Jeremy L <5149279+lymereJ@users.noreply.github.com> Date: Fri, 24 Mar 2023 13:17:54 -0700 Subject: [PATCH 07/45] Logging and test update (#1471) * Update tests and use logging instead of print. * Correct path --- .../applications/database_maintenance.py | 9 +-- .../database_engine/database.py | 5 +- .../test/test_database.py | 70 +++++++++++++++++-- .../test/test_template.py | 6 -- 4 files changed, 72 insertions(+), 18 deletions(-) diff --git a/data/openstudio_standards_data/applications/database_maintenance.py b/data/openstudio_standards_data/applications/database_maintenance.py index f90d2de09c..395bf4a446 100644 --- a/data/openstudio_standards_data/applications/database_maintenance.py +++ b/data/openstudio_standards_data/applications/database_maintenance.py @@ -1,4 +1,5 @@ import sqlite3 +import logging import database_tables as tables from database_engine.database_util import read_csv_to_list_dict, read_json_to_list_dict @@ -12,8 +13,8 @@ def create_openstudio_standards_database_from_csv(conn: sqlite3.Connection): datatable.create_a_table(conn) data = read_csv_to_list_dict(f"{datatable.initial_data_directory}.csv") for record in data: - print(record) - print(datatable.add_a_record(conn, record)) + logging.info(record) + logging.info(datatable.add_a_record(conn, record)) def create_openstudio_standards_database_from_json(conn: sqlite3.Connection): @@ -24,8 +25,8 @@ def create_openstudio_standards_database_from_json(conn: sqlite3.Connection): datatable.create_a_table(conn) data = read_json_to_list_dict(f"{datatable.initial_data_directory}.json") for record in data: - print(record) - print(datatable.add_a_record(conn, record)) + logging.info(record) + logging.info(datatable.add_a_record(conn, record)) def export_openstudio_standards_database_to_csv(conn: sqlite3.Connection, save_dir=""): diff --git a/data/openstudio_standards_data/database_engine/database.py b/data/openstudio_standards_data/database_engine/database.py index 8202ed254f..167181e9bd 100644 --- a/data/openstudio_standards_data/database_engine/database.py +++ b/data/openstudio_standards_data/database_engine/database.py @@ -2,6 +2,7 @@ from sqlite3 import Error import csv import json +import logging DB_FILE = "openstudio_standards_database.db" @@ -18,7 +19,7 @@ def create_connect(db_file): # enable foreign keys execution conn.execute("PRAGMA foreign_keys = 1") except Error as e: - print(e) + logging.error(e) return conn @@ -40,7 +41,7 @@ def create_a_table(self, connection): :param connection: :return: """ - print(f"creating table: {self.data_table_name}") + logging.info(f"creating table: {self.data_table_name}") connection.execute(self._get_create_table_query()) return True diff --git a/data/openstudio_standards_data/test/test_database.py b/data/openstudio_standards_data/test/test_database.py index a7a224d012..3396e901bf 100644 --- a/data/openstudio_standards_data/test/test_database.py +++ b/data/openstudio_standards_data/test/test_database.py @@ -2,12 +2,18 @@ from unittest import mock import os import sqlite3 +import difflib +import glob +import shutil from applications.database_maintenance import ( create_openstudio_standards_database_from_csv, + create_openstudio_standards_database_from_json, + export_openstudio_standards_database_to_csv, + export_openstudio_standards_database_to_json, ) -class TestDatabaseQuries(TestCase): +class TestDatabaseQueries(TestCase): """ Test database - unfinished """ @@ -27,13 +33,23 @@ def test_insert_rows_calls_cursor_method(self): pass -def test_create_database(): - # Create DB - db_name = "openstudio_standards_data" +def create_db(db_name, from_type=""): + # Delete DB if already exists if os.path.isfile(f"{db_name}.db"): os.remove(f"{db_name}.db") conn = sqlite3.connect(f"{db_name}.db") - create_openstudio_standards_database_from_csv(conn) + # Create DB + if from_type == "json": + create_openstudio_standards_database_from_json(conn) + else: + create_openstudio_standards_database_from_csv(conn) + return conn + + +def test_create_export_database(): + # Create DB from JSON file + db_name = "openstudio_standards_data" + conn = create_db(db_name=db_name, from_type="json") # Check that DB exists assert os.path.isfile(f"{db_name}.db") @@ -44,5 +60,47 @@ def test_create_database(): res = cur.fetchall() assert len(res) == 0, f"Foreign key issue: {res}" - # Close DB + # Create a copy of original JSON files + if os.path.isdir("./original_database_files"): + shutil.rmtree("./original_database_files", ignore_errors=True) + shutil.copytree("./database_files", "./original_database_files") + + # Export data to JSON and CSV files + export_openstudio_standards_database_to_json(conn, save_dir="./database_files/") + export_openstudio_standards_database_to_csv(conn, save_dir="./database_files/") conn.close() + + # Regenerate DB from JSON and CSV files + db_name = "openstudio_standards_data_from_csv" + conn_csv = create_db(db_name=db_name, from_type="csv") + db_name = "openstudio_standards_data_from_json" + conn_json = create_db(db_name=db_name, from_type="json") + + # Export both DB to JSON files + if not os.path.isdir("./test/database_files_from_json"): + os.mkdir("./test/database_files_from_json") + if not os.path.isdir("./test/database_files_from_csv"): + os.mkdir("./test/database_files_from_csv") + export_openstudio_standards_database_to_json( + conn_json, save_dir="./test/database_files_from_json/" + ) + export_openstudio_standards_database_to_json( + conn_csv, save_dir="./test/database_files_from_csv/" + ) + conn.close() + + # Compare original JSON files with the ones generated from both DB + # There should be no difference between the JSON files originating + # from a DB generated from JSON or CSV files + filenames = glob.glob("./test/database_files_from_json/*.json") + filenames = [os.path.basename(f) for f in filenames] + for f in filenames: + with open(f"./test/database_files_from_json/{f}") as f_from_json: + fc_from_json = f_from_json.readlines() + with open(f"./test/database_files_from_csv/{f}") as f_from_csv: + fc_from_csv = f_from_csv.readlines() + with open(f"./original_database_files/{f}") as f_org: + fc_org = f_org.readlines() + assert ( + fc_from_json == fc_from_csv == fc_org + ), f"Content is different in {f}.json files" diff --git a/data/openstudio_standards_data/test/test_template.py b/data/openstudio_standards_data/test/test_template.py index 24fc41d703..f71dd90762 100644 --- a/data/openstudio_standards_data/test/test_template.py +++ b/data/openstudio_standards_data/test/test_template.py @@ -6,12 +6,6 @@ ) db_name = "openstudio_standards_data" -if os.path.isfile(f"{db_name}.db"): - os.remove(f"{db_name}.db") -conn = sqlite3.connect(f"{db_name}.db") -create_openstudio_standards_database_from_csv(conn) -conn.close() -assert os.path.isfile(f"{db_name}.db") def test_get_template_data__true(): From 401485cfa00a8936f6dc006e1b7fd181e1c1603e Mon Sep 17 00:00:00 2001 From: Weili Xu Date: Tue, 28 Mar 2023 09:06:14 -0700 Subject: [PATCH 08/45] fix typo in the script and data files --- data/openstudio_standards_data/Pipfile.lock | 267 -------- .../create_openstudio_standards_json.py | 4 +- .../applications/form/update_space_data.py | 16 +- .../level_2_lighting_space_types.csv | 2 +- .../level_2_lighting_space_types.json | 572 +++++++++--------- .../level_2_ventilation_space_types.csv | 2 +- .../level_2_ventilation_space_types.json | 346 +++++------ .../level_2_lighting_space_types.py | 10 +- .../level_2_ventilation_space_types.py | 10 +- .../query/fetch/space.py | 4 +- 10 files changed, 483 insertions(+), 750 deletions(-) delete mode 100644 data/openstudio_standards_data/Pipfile.lock diff --git a/data/openstudio_standards_data/Pipfile.lock b/data/openstudio_standards_data/Pipfile.lock deleted file mode 100644 index b409a88def..0000000000 --- a/data/openstudio_standards_data/Pipfile.lock +++ /dev/null @@ -1,267 +0,0 @@ -{ - "_meta": { - "hash": { - "sha256": "8ce59fe81cf863b2197b2f755c3c40c7544bce0aed72fcf72933595a7de8e9a4" - }, - "pipfile-spec": 6, - "requires": { - "python_version": "3.10" - }, - "sources": [ - { - "name": "pypi", - "url": "https://pypi.org/simple", - "verify_ssl": true - } - ] - }, - "default": { - "attrs": { - "hashes": [ - "sha256:29e95c7f6778868dbd49170f98f8818f78f3dc5e0e37c0b1f474e3561b240836", - "sha256:c9227bfc2f01993c03f68db37d1d15c9690188323c067c641f1a35ca58185f99" - ], - "markers": "python_version >= '3.6'", - "version": "==22.2.0" - }, - "black": { - "hashes": [ - "sha256:101c69b23df9b44247bd88e1d7e90154336ac4992502d4197bdac35dd7ee3320", - "sha256:159a46a4947f73387b4d83e87ea006dbb2337eab6c879620a3ba52699b1f4351", - "sha256:1f58cbe16dfe8c12b7434e50ff889fa479072096d79f0a7f25e4ab8e94cd8350", - "sha256:229351e5a18ca30f447bf724d007f890f97e13af070bb6ad4c0a441cd7596a2f", - "sha256:436cc9167dd28040ad90d3b404aec22cedf24a6e4d7de221bec2730ec0c97bcf", - "sha256:559c7a1ba9a006226f09e4916060982fd27334ae1998e7a38b3f33a37f7a2148", - "sha256:7412e75863aa5c5411886804678b7d083c7c28421210180d67dfd8cf1221e1f4", - "sha256:77d86c9f3db9b1bf6761244bc0b3572a546f5fe37917a044e02f3166d5aafa7d", - "sha256:82d9fe8fee3401e02e79767016b4907820a7dc28d70d137eb397b92ef3cc5bfc", - "sha256:9eedd20838bd5d75b80c9f5487dbcb06836a43833a37846cf1d8c1cc01cef59d", - "sha256:c116eed0efb9ff870ded8b62fe9f28dd61ef6e9ddd28d83d7d264a38417dcee2", - "sha256:d30b212bffeb1e252b31dd269dfae69dd17e06d92b87ad26e23890f3efea366f" - ], - "index": "pypi", - "version": "==22.12.0" - }, - "click": { - "hashes": [ - "sha256:7682dc8afb30297001674575ea00d1814d808d6a36af415a82bd481d37ba7b8e", - "sha256:bb4d8133cb15a609f44e8213d9b391b0809795062913b383c62be0ee95b1db48" - ], - "markers": "python_version >= '3.7'", - "version": "==8.1.3" - }, - "colorama": { - "hashes": [ - "sha256:08695f5cb7ed6e0531a20572697297273c47b8cae5a63ffc6d6ed5c201be6e44", - "sha256:4f1d9991f5acc0ca119f9d443620b77f9d6b33703e51011c16baf57afb285fc6" - ], - "markers": "sys_platform == 'win32'", - "version": "==0.4.6" - }, - "exceptiongroup": { - "hashes": [ - "sha256:327cbda3da756e2de031a3107b81ab7b3770a602c4d16ca618298c526f4bec1e", - "sha256:bcb67d800a4497e1b404c2dd44fca47d3b7a5e5433dbab67f96c1a685cdfdf23" - ], - "markers": "python_version < '3.11'", - "version": "==1.1.0" - }, - "iniconfig": { - "hashes": [ - "sha256:2d91e135bf72d31a410b17c16da610a82cb55f6b0477d1a902134b24a455b8b3", - "sha256:b6a85871a79d2e3b22d2d1b94ac2824226a63c6b741c88f7ae975f18b6778374" - ], - "markers": "python_version >= '3.7'", - "version": "==2.0.0" - }, - "mypy-extensions": { - "hashes": [ - "sha256:090fedd75945a69ae91ce1303b5824f428daf5a028d2f6ab8a299250a846f15d", - "sha256:2d82818f5bb3e369420cb3c4060a7970edba416647068eb4c5343488a6c604a8" - ], - "version": "==0.4.3" - }, - "packaging": { - "hashes": [ - "sha256:714ac14496c3e68c99c29b00845f7a2b85f3bb6f1078fd9f72fd20f0570002b2", - "sha256:b6ad297f8907de0fa2fe1ccbd26fdaf387f5f47c7275fedf8cce89f99446cf97" - ], - "markers": "python_version >= '3.7'", - "version": "==23.0" - }, - "pathspec": { - "hashes": [ - "sha256:3c95343af8b756205e2aba76e843ba9520a24dd84f68c22b9f93251507509dd6", - "sha256:56200de4077d9d0791465aa9095a01d421861e405b5096955051deefd697d6f6" - ], - "markers": "python_version >= '3.7'", - "version": "==0.10.3" - }, - "platformdirs": { - "hashes": [ - "sha256:83c8f6d04389165de7c9b6f0c682439697887bca0aa2f1c87ef1826be3584490", - "sha256:e1fea1fe471b9ff8332e229df3cb7de4f53eeea4998d3b6bfff542115e998bd2" - ], - "markers": "python_version >= '3.7'", - "version": "==2.6.2" - }, - "pluggy": { - "hashes": [ - "sha256:4224373bacce55f955a878bf9cfa763c1e360858e330072059e10bad68531159", - "sha256:74134bbf457f031a36d68416e1509f34bd5ccc019f0bcc952c7b909d06b37bd3" - ], - "markers": "python_version >= '3.6'", - "version": "==1.0.0" - }, - "pytest": { - "hashes": [ - "sha256:c7c6ca206e93355074ae32f7403e8ea12163b1163c976fee7d4d84027c162be5", - "sha256:d45e0952f3727241918b8fd0f376f5ff6b301cc0777c6f9a556935c92d8a7d42" - ], - "index": "pypi", - "version": "==7.2.1" - }, - "tomli": { - "hashes": [ - "sha256:939de3e7a6161af0c887ef91b7d41a53e7c5a1ca976325f429cb46ea9bc30ecc", - "sha256:de526c12914f0c550d15924c62d72abc48d6fe7364aa87328337a31007fe8a4f" - ], - "markers": "python_full_version < '3.11.0a7'", - "version": "==2.0.1" - } - }, - "develop": { - "attrs": { - "hashes": [ - "sha256:29e95c7f6778868dbd49170f98f8818f78f3dc5e0e37c0b1f474e3561b240836", - "sha256:c9227bfc2f01993c03f68db37d1d15c9690188323c067c641f1a35ca58185f99" - ], - "markers": "python_version >= '3.6'", - "version": "==22.2.0" - }, - "colorama": { - "hashes": [ - "sha256:08695f5cb7ed6e0531a20572697297273c47b8cae5a63ffc6d6ed5c201be6e44", - "sha256:4f1d9991f5acc0ca119f9d443620b77f9d6b33703e51011c16baf57afb285fc6" - ], - "markers": "sys_platform == 'win32'", - "version": "==0.4.6" - }, - "coverage": { - "extras": [ - "toml" - ], - "hashes": [ - "sha256:051afcbd6d2ac39298d62d340f94dbb6a1f31de06dfaf6fcef7b759dd3860c45", - "sha256:0a1890fca2962c4f1ad16551d660b46ea77291fba2cc21c024cd527b9d9c8809", - "sha256:0ee30375b409d9a7ea0f30c50645d436b6f5dfee254edffd27e45a980ad2c7f4", - "sha256:13250b1f0bd023e0c9f11838bdeb60214dd5b6aaf8e8d2f110c7e232a1bff83b", - "sha256:17e01dd8666c445025c29684d4aabf5a90dc6ef1ab25328aa52bedaa95b65ad7", - "sha256:19245c249aa711d954623d94f23cc94c0fd65865661f20b7781210cb97c471c0", - "sha256:1caed2367b32cc80a2b7f58a9f46658218a19c6cfe5bc234021966dc3daa01f0", - "sha256:1f66862d3a41674ebd8d1a7b6f5387fe5ce353f8719040a986551a545d7d83ea", - "sha256:220e3fa77d14c8a507b2d951e463b57a1f7810a6443a26f9b7591ef39047b1b2", - "sha256:276f4cd0001cd83b00817c8db76730938b1ee40f4993b6a905f40a7278103b3a", - "sha256:29de916ba1099ba2aab76aca101580006adfac5646de9b7c010a0f13867cba45", - "sha256:2a7f23bbaeb2a87f90f607730b45564076d870f1fb07b9318d0c21f36871932b", - "sha256:2c407b1950b2d2ffa091f4e225ca19a66a9bd81222f27c56bd12658fc5ca1209", - "sha256:30b5fec1d34cc932c1bc04017b538ce16bf84e239378b8f75220478645d11fca", - "sha256:3c2155943896ac78b9b0fd910fb381186d0c345911f5333ee46ac44c8f0e43ab", - "sha256:411d4ff9d041be08fdfc02adf62e89c735b9468f6d8f6427f8a14b6bb0a85095", - "sha256:436e103950d05b7d7f55e39beeb4d5be298ca3e119e0589c0227e6d0b01ee8c7", - "sha256:49640bda9bda35b057b0e65b7c43ba706fa2335c9a9896652aebe0fa399e80e6", - "sha256:4a950f83fd3f9bca23b77442f3a2b2ea4ac900944d8af9993743774c4fdc57af", - "sha256:50a6adc2be8edd7ee67d1abc3cd20678987c7b9d79cd265de55941e3d0d56499", - "sha256:52ab14b9e09ce052237dfe12d6892dd39b0401690856bcfe75d5baba4bfe2831", - "sha256:54f7e9705e14b2c9f6abdeb127c390f679f6dbe64ba732788d3015f7f76ef637", - "sha256:66e50680e888840c0995f2ad766e726ce71ca682e3c5f4eee82272c7671d38a2", - "sha256:790e4433962c9f454e213b21b0fd4b42310ade9c077e8edcb5113db0818450cb", - "sha256:7a38362528a9115a4e276e65eeabf67dcfaf57698e17ae388599568a78dcb029", - "sha256:7b05ed4b35bf6ee790832f68932baf1f00caa32283d66cc4d455c9e9d115aafc", - "sha256:7e109f1c9a3ece676597831874126555997c48f62bddbcace6ed17be3e372de8", - "sha256:949844af60ee96a376aac1ded2a27e134b8c8d35cc006a52903fc06c24a3296f", - "sha256:95304068686545aa368b35dfda1cdfbbdbe2f6fe43de4a2e9baa8ebd71be46e2", - "sha256:9e662e6fc4f513b79da5d10a23edd2b87685815b337b1a30cd11307a6679148d", - "sha256:a9fed35ca8c6e946e877893bbac022e8563b94404a605af1d1e6accc7eb73289", - "sha256:b69522b168a6b64edf0c33ba53eac491c0a8f5cc94fa4337f9c6f4c8f2f5296c", - "sha256:b78729038abea6a5df0d2708dce21e82073463b2d79d10884d7d591e0f385ded", - "sha256:b8c56bec53d6e3154eaff6ea941226e7bd7cc0d99f9b3756c2520fc7a94e6d96", - "sha256:b9727ac4f5cf2cbf87880a63870b5b9730a8ae3a4a360241a0fdaa2f71240ff0", - "sha256:ba3027deb7abf02859aca49c865ece538aee56dcb4871b4cced23ba4d5088904", - "sha256:be9fcf32c010da0ba40bf4ee01889d6c737658f4ddff160bd7eb9cac8f094b21", - "sha256:c18d47f314b950dbf24a41787ced1474e01ca816011925976d90a88b27c22b89", - "sha256:c76a3075e96b9c9ff00df8b5f7f560f5634dffd1658bafb79eb2682867e94f78", - "sha256:cbfcba14a3225b055a28b3199c3d81cd0ab37d2353ffd7f6fd64844cebab31ad", - "sha256:d254666d29540a72d17cc0175746cfb03d5123db33e67d1020e42dae611dc196", - "sha256:d66187792bfe56f8c18ba986a0e4ae44856b1c645336bd2c776e3386da91e1dd", - "sha256:d8d04e755934195bdc1db45ba9e040b8d20d046d04d6d77e71b3b34a8cc002d0", - "sha256:d8f3e2e0a1d6777e58e834fd5a04657f66affa615dae61dd67c35d1568c38882", - "sha256:e057e74e53db78122a3979f908973e171909a58ac20df05c33998d52e6d35757", - "sha256:e4ce984133b888cc3a46867c8b4372c7dee9cee300335e2925e197bcd45b9e16", - "sha256:ea76dbcad0b7b0deb265d8c36e0801abcddf6cc1395940a24e3595288b405ca0", - "sha256:ecb0f73954892f98611e183f50acdc9e21a4653f294dfbe079da73c6378a6f47", - "sha256:ef14d75d86f104f03dea66c13188487151760ef25dd6b2dbd541885185f05f40", - "sha256:f26648e1b3b03b6022b48a9b910d0ae209e2d51f50441db5dce5b530fad6d9b1", - "sha256:f67472c09a0c7486e27f3275f617c964d25e35727af952869dd496b9b5b7f6a3" - ], - "markers": "python_version >= '3.7'", - "version": "==7.0.5" - }, - "exceptiongroup": { - "hashes": [ - "sha256:327cbda3da756e2de031a3107b81ab7b3770a602c4d16ca618298c526f4bec1e", - "sha256:bcb67d800a4497e1b404c2dd44fca47d3b7a5e5433dbab67f96c1a685cdfdf23" - ], - "markers": "python_version < '3.11'", - "version": "==1.1.0" - }, - "iniconfig": { - "hashes": [ - "sha256:2d91e135bf72d31a410b17c16da610a82cb55f6b0477d1a902134b24a455b8b3", - "sha256:b6a85871a79d2e3b22d2d1b94ac2824226a63c6b741c88f7ae975f18b6778374" - ], - "markers": "python_version >= '3.7'", - "version": "==2.0.0" - }, - "packaging": { - "hashes": [ - "sha256:714ac14496c3e68c99c29b00845f7a2b85f3bb6f1078fd9f72fd20f0570002b2", - "sha256:b6ad297f8907de0fa2fe1ccbd26fdaf387f5f47c7275fedf8cce89f99446cf97" - ], - "markers": "python_version >= '3.7'", - "version": "==23.0" - }, - "pluggy": { - "hashes": [ - "sha256:4224373bacce55f955a878bf9cfa763c1e360858e330072059e10bad68531159", - "sha256:74134bbf457f031a36d68416e1509f34bd5ccc019f0bcc952c7b909d06b37bd3" - ], - "markers": "python_version >= '3.6'", - "version": "==1.0.0" - }, - "pytest": { - "hashes": [ - "sha256:c7c6ca206e93355074ae32f7403e8ea12163b1163c976fee7d4d84027c162be5", - "sha256:d45e0952f3727241918b8fd0f376f5ff6b301cc0777c6f9a556935c92d8a7d42" - ], - "index": "pypi", - "version": "==7.2.1" - }, - "pytest-cov": { - "hashes": [ - "sha256:2feb1b751d66a8bd934e5edfa2e961d11309dc37b73b0eabe73b5945fee20f6b", - "sha256:996b79efde6433cdbd0088872dbc5fb3ed7fe1578b68cdbba634f14bb8dd0470" - ], - "index": "pypi", - "version": "==4.0.0" - }, - "tomli": { - "hashes": [ - "sha256:939de3e7a6161af0c887ef91b7d41a53e7c5a1ca976325f429cb46ea9bc30ecc", - "sha256:de526c12914f0c550d15924c62d72abc48d6fe7364aa87328337a31007fe8a4f" - ], - "markers": "python_full_version < '3.11.0a7'", - "version": "==2.0.1" - } - } -} diff --git a/data/openstudio_standards_data/applications/create_openstudio_standards_json.py b/data/openstudio_standards_data/applications/create_openstudio_standards_json.py index 0cb24a4066..3714269e51 100644 --- a/data/openstudio_standards_data/applications/create_openstudio_standards_json.py +++ b/data/openstudio_standards_data/applications/create_openstudio_standards_json.py @@ -51,8 +51,8 @@ def create_openstudio_standards_space_data_json( sp_data["ventilation_standard"] = template["ventilation_standard"] sp_data["space_type"] = space["space_type"] - lpd_id = int(space["level_3_lighting_defintion_id"]) - vent_id = int(space["level_3_ventilation_defintion_id"]) + lpd_id = int(space["level_3_lighting_definition_id"]) + vent_id = int(space["level_3_ventilation_definition_id"]) if lighting_standard_table not in standard_data_tables.keys(): light_table = fetch_table(conn, lighting_standard_table) standard_data_tables[lighting_standard_table] = light_table diff --git a/data/openstudio_standards_data/applications/form/update_space_data.py b/data/openstudio_standards_data/applications/form/update_space_data.py index 5b92ad8545..326ea493a3 100644 --- a/data/openstudio_standards_data/applications/form/update_space_data.py +++ b/data/openstudio_standards_data/applications/form/update_space_data.py @@ -19,8 +19,8 @@ SPACE_TABLE_HEADER = [ "space_type", - "level_3_lighting_defintion_id", - "level_3_ventilation_defintion_id", + "level_3_lighting_definition_id", + "level_3_ventilation_definition_id", ] FETCH_SPACE_TO_TABLE_QUEYR = f""" @@ -77,11 +77,11 @@ def update_openstudio_standards_space_data( # loop through the rows in table for row in cur: - level_3_lighting_defintion_id = row[ - SPACE_TABLE_HEADER.index("level_3_lighting_defintion_id") + level_3_lighting_definition_id = row[ + SPACE_TABLE_HEADER.index("level_3_lighting_definition_id") ] - level_3_ventilation_defintion_id = row[ - SPACE_TABLE_HEADER.index("level_3_ventilation_defintion_id") + level_3_ventilation_definition_id = row[ + SPACE_TABLE_HEADER.index("level_3_ventilation_definition_id") ] # update lighting @@ -102,7 +102,7 @@ def update_openstudio_standards_space_data( search_condition = ( "id=%s AND lighting_primary_space_type='%s' AND lighting_secondary_space_type='%s'" % ( - level_3_lighting_defintion_id, + level_3_lighting_definition_id, lighting_primary_space_type, lighting_secondary_space_type, ) @@ -129,7 +129,7 @@ def update_openstudio_standards_space_data( search_condition = ( "id=%s AND ventilation_primary_space_type='%s' AND ventilation_secondary_space_type='%s'" % ( - level_3_ventilation_defintion_id, + level_3_ventilation_definition_id, ventilation_primary_space_type, ventilation_secondary_space_type, ) diff --git a/data/openstudio_standards_data/database_files/level_2_lighting_space_types.csv b/data/openstudio_standards_data/database_files/level_2_lighting_space_types.csv index ff4290bc11..7eaf0760dd 100644 --- a/data/openstudio_standards_data/database_files/level_2_lighting_space_types.csv +++ b/data/openstudio_standards_data/database_files/level_2_lighting_space_types.csv @@ -1,4 +1,4 @@ -lighting_space_type_name,level_3_lighting_definition_table,level_3_lighting_defintion_id +lighting_space_type_name,level_3_lighting_definition_table,level_3_lighting_definition_id bam_automotive_facility,level_3_lighting_90_1_2004,1 bam_convention_center,level_3_lighting_90_1_2004,2 bam_courthouse,level_3_lighting_90_1_2004,3 diff --git a/data/openstudio_standards_data/database_files/level_2_lighting_space_types.json b/data/openstudio_standards_data/database_files/level_2_lighting_space_types.json index 653f4d6452..a66c4aa138 100644 --- a/data/openstudio_standards_data/database_files/level_2_lighting_space_types.json +++ b/data/openstudio_standards_data/database_files/level_2_lighting_space_types.json @@ -2,1431 +2,1431 @@ { "lighting_space_type_name": "bam_automotive_facility", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 1 + "level_3_lighting_definition_id": 1 }, { "lighting_space_type_name": "bam_convention_center", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 2 + "level_3_lighting_definition_id": 2 }, { "lighting_space_type_name": "bam_courthouse", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 3 + "level_3_lighting_definition_id": 3 }, { "lighting_space_type_name": "bam_dinin_bar_lounge_leisure", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 4 + "level_3_lighting_definition_id": 4 }, { "lighting_space_type_name": "bam_dining_cafeteria_fast_food", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 5 + "level_3_lighting_definition_id": 5 }, { "lighting_space_type_name": "bam_dining_family", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 6 + "level_3_lighting_definition_id": 6 }, { "lighting_space_type_name": "bam_dormitory", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 7 + "level_3_lighting_definition_id": 7 }, { "lighting_space_type_name": "bam_exercise_center", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 8 + "level_3_lighting_definition_id": 8 }, { "lighting_space_type_name": "bam_fire_station", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 23 + "level_3_lighting_definition_id": 23 }, { "lighting_space_type_name": "bam_gymnasium", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 9 + "level_3_lighting_definition_id": 9 }, { "lighting_space_type_name": "bam_healthcare_clinic", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 10 + "level_3_lighting_definition_id": 10 }, { "lighting_space_type_name": "bam_hospital", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 11 + "level_3_lighting_definition_id": 11 }, { "lighting_space_type_name": "bam_hotel", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 12 + "level_3_lighting_definition_id": 12 }, { "lighting_space_type_name": "bam_library", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 13 + "level_3_lighting_definition_id": 13 }, { "lighting_space_type_name": "bam_manufacturing_facility", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 14 + "level_3_lighting_definition_id": 14 }, { "lighting_space_type_name": "bam_motel", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 15 + "level_3_lighting_definition_id": 15 }, { "lighting_space_type_name": "bam_motion_picture_theater", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 16 + "level_3_lighting_definition_id": 16 }, { "lighting_space_type_name": "bam_multifamily", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 17 + "level_3_lighting_definition_id": 17 }, { "lighting_space_type_name": "bam_museum", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 18 + "level_3_lighting_definition_id": 18 }, { "lighting_space_type_name": "bam_office", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 19 + "level_3_lighting_definition_id": 19 }, { "lighting_space_type_name": "bam_parking_garage", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 20 + "level_3_lighting_definition_id": 20 }, { "lighting_space_type_name": "bam_penitentiary", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 21 + "level_3_lighting_definition_id": 21 }, { "lighting_space_type_name": "bam_performing_arts_theater", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 22 + "level_3_lighting_definition_id": 22 }, { "lighting_space_type_name": "bam_police_station", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 23 + "level_3_lighting_definition_id": 23 }, { "lighting_space_type_name": "bam_post_office", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 24 + "level_3_lighting_definition_id": 24 }, { "lighting_space_type_name": "bam_religious_facility", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 25 + "level_3_lighting_definition_id": 25 }, { "lighting_space_type_name": "bam_retail", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 26 + "level_3_lighting_definition_id": 26 }, { "lighting_space_type_name": "bam_school_university", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 27 + "level_3_lighting_definition_id": 27 }, { "lighting_space_type_name": "bam_sports_arena", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 28 + "level_3_lighting_definition_id": 28 }, { "lighting_space_type_name": "bam_town_hall", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 29 + "level_3_lighting_definition_id": 29 }, { "lighting_space_type_name": "bam_transportation", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 30 + "level_3_lighting_definition_id": 30 }, { "lighting_space_type_name": "bam_warehouse", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 31 + "level_3_lighting_definition_id": 31 }, { "lighting_space_type_name": "bam_workshop", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 32 + "level_3_lighting_definition_id": 32 }, { "lighting_space_type_name": "office_enclosed_small", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 33 + "level_3_lighting_definition_id": 33 }, { "lighting_space_type_name": "office_enclosed_large", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 33 + "level_3_lighting_definition_id": 33 }, { "lighting_space_type_name": "office_open", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 34 + "level_3_lighting_definition_id": 34 }, { "lighting_space_type_name": "conference_meeting_multipurpose", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 35 + "level_3_lighting_definition_id": 35 }, { "lighting_space_type_name": "classroom_lecture_training_general", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 36 + "level_3_lighting_definition_id": 36 }, { "lighting_space_type_name": "classroom_lecture_training_penitentiary", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 37 + "level_3_lighting_definition_id": 37 }, { "lighting_space_type_name": "lobby_general", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 38 + "level_3_lighting_definition_id": 38 }, { "lighting_space_type_name": "lobby_hotel", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 39 + "level_3_lighting_definition_id": 39 }, { "lighting_space_type_name": "lobby_performing_arts_theater", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 40 + "level_3_lighting_definition_id": 40 }, { "lighting_space_type_name": "lobby_motion_picture_theater", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 41 + "level_3_lighting_definition_id": 41 }, { "lighting_space_type_name": "lobby_visually_impaired", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 38 + "level_3_lighting_definition_id": 38 }, { "lighting_space_type_name": "lobby_elevator", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 38 + "level_3_lighting_definition_id": 38 }, { "lighting_space_type_name": "audience_seating_general", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 42 + "level_3_lighting_definition_id": 42 }, { "lighting_space_type_name": "audience_seating_gymnasium", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 43 + "level_3_lighting_definition_id": 43 }, { "lighting_space_type_name": "audience_seating_exercise_center", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 44 + "level_3_lighting_definition_id": 44 }, { "lighting_space_type_name": "audience_seating_convention_center", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 45 + "level_3_lighting_definition_id": 45 }, { "lighting_space_type_name": "audience_seating_penitentiary", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 46 + "level_3_lighting_definition_id": 46 }, { "lighting_space_type_name": "audience_seating_religious_facility", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 47 + "level_3_lighting_definition_id": 47 }, { "lighting_space_type_name": "audience_seating_sports_arena", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 48 + "level_3_lighting_definition_id": 48 }, { "lighting_space_type_name": "audience_seating_performing_arts_theater", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 49 + "level_3_lighting_definition_id": 49 }, { "lighting_space_type_name": "audience_seating_motion_picture_theater", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 50 + "level_3_lighting_definition_id": 50 }, { "lighting_space_type_name": "audience_seating_transportation", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 51 + "level_3_lighting_definition_id": 51 }, { "lighting_space_type_name": "audience_seating_auditorium", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 42 + "level_3_lighting_definition_id": 42 }, { "lighting_space_type_name": "atrium_first_three_floor", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 52 + "level_3_lighting_definition_id": 52 }, { "lighting_space_type_name": "atrium_each_additional_floor", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 53 + "level_3_lighting_definition_id": 53 }, { "lighting_space_type_name": "lounge_breakroom_general", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 54 + "level_3_lighting_definition_id": 54 }, { "lighting_space_type_name": "lounge_breakroom_healthcare_facility", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 55 + "level_3_lighting_definition_id": 55 }, { "lighting_space_type_name": "dining_general", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 56 + "level_3_lighting_definition_id": 56 }, { "lighting_space_type_name": "dining_penitentiary", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 57 + "level_3_lighting_definition_id": 57 }, { "lighting_space_type_name": "dining_hotel", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 58 + "level_3_lighting_definition_id": 58 }, { "lighting_space_type_name": "dining_motel", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 59 + "level_3_lighting_definition_id": 59 }, { "lighting_space_type_name": "dining_bar_lounge_leisure", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 60 + "level_3_lighting_definition_id": 60 }, { "lighting_space_type_name": "dining_family", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 61 + "level_3_lighting_definition_id": 61 }, { "lighting_space_type_name": "dining_cafeteria_fast_food", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 56 + "level_3_lighting_definition_id": 56 }, { "lighting_space_type_name": "dining_visually_impaired", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 56 + "level_3_lighting_definition_id": 56 }, { "lighting_space_type_name": "kitchen", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 62 + "level_3_lighting_definition_id": 62 }, { "lighting_space_type_name": "laboratory_classroom", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 63 + "level_3_lighting_definition_id": 63 }, { "lighting_space_type_name": "laboratory_all_other", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 63 + "level_3_lighting_definition_id": 63 }, { "lighting_space_type_name": "restroom_visually_impaired", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 64 + "level_3_lighting_definition_id": 64 }, { "lighting_space_type_name": "restroom_all_other", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 64 + "level_3_lighting_definition_id": 64 }, { "lighting_space_type_name": "performing_arts_dressing_room", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 65 + "level_3_lighting_definition_id": 65 }, { "lighting_space_type_name": "corridor_general", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 66 + "level_3_lighting_definition_id": 66 }, { "lighting_space_type_name": "corridor_hospital", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 67 + "level_3_lighting_definition_id": 67 }, { "lighting_space_type_name": "corridor_manufacturing_facility", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 68 + "level_3_lighting_definition_id": 68 }, { "lighting_space_type_name": "corridor_visually_impaired", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 66 + "level_3_lighting_definition_id": 66 }, { "lighting_space_type_name": "stairway", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 69 + "level_3_lighting_definition_id": 69 }, { "lighting_space_type_name": "stairwell", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 69 + "level_3_lighting_definition_id": 69 }, { "lighting_space_type_name": "storage_ all_other_small", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 70 + "level_3_lighting_definition_id": 70 }, { "lighting_space_type_name": "storage_ all_other_large", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 70 + "level_3_lighting_definition_id": 70 }, { "lighting_space_type_name": "storage_hospital_small", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 71 + "level_3_lighting_definition_id": 71 }, { "lighting_space_type_name": "storage_hospital_large", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 71 + "level_3_lighting_definition_id": 71 }, { "lighting_space_type_name": "storage_inactive", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 72 + "level_3_lighting_definition_id": 72 }, { "lighting_space_type_name": "storage_inactive_museum", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 73 + "level_3_lighting_definition_id": 73 }, { "lighting_space_type_name": "electrical_mechanical", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 74 + "level_3_lighting_definition_id": 74 }, { "lighting_space_type_name": "workshop", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 75 + "level_3_lighting_definition_id": 75 }, { "lighting_space_type_name": "gymnasium_playing_area", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 76 + "level_3_lighting_definition_id": 76 }, { "lighting_space_type_name": "gymnasium_exercise_area", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 77 + "level_3_lighting_definition_id": 77 }, { "lighting_space_type_name": "courtroom", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 78 + "level_3_lighting_definition_id": 78 }, { "lighting_space_type_name": "confinement_cells", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 79 + "level_3_lighting_definition_id": 79 }, { "lighting_space_type_name": "judges_chambers", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 80 + "level_3_lighting_definition_id": 80 }, { "lighting_space_type_name": "emergency_vehicle_garage", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 81 + "level_3_lighting_definition_id": 81 }, { "lighting_space_type_name": "firestation_sleeping_quarters", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 82 + "level_3_lighting_definition_id": 82 }, { "lighting_space_type_name": "post_office_sorting_area", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 83 + "level_3_lighting_definition_id": 83 }, { "lighting_space_type_name": "exhibit_convention_center", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 84 + "level_3_lighting_definition_id": 84 }, { "lighting_space_type_name": "library_cataloging", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 85 + "level_3_lighting_definition_id": 85 }, { "lighting_space_type_name": "library_stacks", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 86 + "level_3_lighting_definition_id": 86 }, { "lighting_space_type_name": "library_reading", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 87 + "level_3_lighting_definition_id": 87 }, { "lighting_space_type_name": "emergency_room", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 88 + "level_3_lighting_definition_id": 88 }, { "lighting_space_type_name": "recovery", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 89 + "level_3_lighting_definition_id": 89 }, { "lighting_space_type_name": "nurses_station", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 90 + "level_3_lighting_definition_id": 90 }, { "lighting_space_type_name": "exam_treatment", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 91 + "level_3_lighting_definition_id": 91 }, { "lighting_space_type_name": "pharmacy", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 92 + "level_3_lighting_definition_id": 92 }, { "lighting_space_type_name": "patient_room", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 93 + "level_3_lighting_definition_id": 93 }, { "lighting_space_type_name": "operating_room", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 94 + "level_3_lighting_definition_id": 94 }, { "lighting_space_type_name": "nursery", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 95 + "level_3_lighting_definition_id": 95 }, { "lighting_space_type_name": "medical_supply", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 96 + "level_3_lighting_definition_id": 96 }, { "lighting_space_type_name": "physical_therapy", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 97 + "level_3_lighting_definition_id": 97 }, { "lighting_space_type_name": "imaging", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 98 + "level_3_lighting_definition_id": 98 }, { "lighting_space_type_name": "laundry_washing", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 99 + "level_3_lighting_definition_id": 99 }, { "lighting_space_type_name": "automotive", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 100 + "level_3_lighting_definition_id": 100 }, { "lighting_space_type_name": "manufacturing_low_bay", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 101 + "level_3_lighting_definition_id": 101 }, { "lighting_space_type_name": "manufacturing_high_bay", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 102 + "level_3_lighting_definition_id": 102 }, { "lighting_space_type_name": "detailed_manufacuring", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 103 + "level_3_lighting_definition_id": 103 }, { "lighting_space_type_name": "manufacturing_equipment_room", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 104 + "level_3_lighting_definition_id": 104 }, { "lighting_space_type_name": "manufacturing_control", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 105 + "level_3_lighting_definition_id": 105 }, { "lighting_space_type_name": "guest_room", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 106 + "level_3_lighting_definition_id": 106 }, { "lighting_space_type_name": "dormitory_living_quarters", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 107 + "level_3_lighting_definition_id": 107 }, { "lighting_space_type_name": "museum_exhibit_area", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 108 + "level_3_lighting_definition_id": 108 }, { "lighting_space_type_name": "museum_restoration", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 109 + "level_3_lighting_definition_id": 109 }, { "lighting_space_type_name": "banking_activity", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 110 + "level_3_lighting_definition_id": 110 }, { "lighting_space_type_name": "worship_pulpit_choir_area", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 111 + "level_3_lighting_definition_id": 111 }, { "lighting_space_type_name": "fellowship_hall_religious_facility", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 112 + "level_3_lighting_definition_id": 112 }, { "lighting_space_type_name": "sales", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 113 + "level_3_lighting_definition_id": 113 }, { "lighting_space_type_name": "retail_mall_concourse", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 114 + "level_3_lighting_definition_id": 114 }, { "lighting_space_type_name": "sports_arena_ring_sports_area", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 115 + "level_3_lighting_definition_id": 115 }, { "lighting_space_type_name": "sports_arena_court_sports_area", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 116 + "level_3_lighting_definition_id": 116 }, { "lighting_space_type_name": "sports_arena_indoor_playing_field", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 117 + "level_3_lighting_definition_id": 117 }, { "lighting_space_type_name": "warehouse_bulk_storage", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 119 + "level_3_lighting_definition_id": 119 }, { "lighting_space_type_name": "parking_area_interior", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 120 + "level_3_lighting_definition_id": 120 }, { "lighting_space_type_name": "airport_concourse", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 121 + "level_3_lighting_definition_id": 121 }, { "lighting_space_type_name": "baggage_carousel", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 122 + "level_3_lighting_definition_id": 122 }, { "lighting_space_type_name": "transportation_ticket_counter", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 123 + "level_3_lighting_definition_id": 123 }, { "lighting_space_type_name": "sales_display_type_1", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 124 + "level_3_lighting_definition_id": 124 }, { "lighting_space_type_name": "sales_display_type_2", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 124 + "level_3_lighting_definition_id": 124 }, { "lighting_space_type_name": "sales_display_type_3", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 125 + "level_3_lighting_definition_id": 125 }, { "lighting_space_type_name": "sales_display_type_4", "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_defintion_id": 125 + "level_3_lighting_definition_id": 125 }, { "lighting_space_type_name": "bam_automotive_facility", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 1 + "level_3_lighting_definition_id": 1 }, { "lighting_space_type_name": "bam_convention_center", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 2 + "level_3_lighting_definition_id": 2 }, { "lighting_space_type_name": "bam_courthouse", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 3 + "level_3_lighting_definition_id": 3 }, { "lighting_space_type_name": "bam_dinin_bar_lounge_leisure", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 4 + "level_3_lighting_definition_id": 4 }, { "lighting_space_type_name": "bam_dining_cafeteria_fast_food", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 5 + "level_3_lighting_definition_id": 5 }, { "lighting_space_type_name": "bam_dining_family", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 6 + "level_3_lighting_definition_id": 6 }, { "lighting_space_type_name": "bam_dormitory", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 7 + "level_3_lighting_definition_id": 7 }, { "lighting_space_type_name": "bam_exercise_center", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 8 + "level_3_lighting_definition_id": 8 }, { "lighting_space_type_name": "bam_fire_station", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 9 + "level_3_lighting_definition_id": 9 }, { "lighting_space_type_name": "bam_gymnasium", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 10 + "level_3_lighting_definition_id": 10 }, { "lighting_space_type_name": "bam_healthcare_clinic", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 11 + "level_3_lighting_definition_id": 11 }, { "lighting_space_type_name": "bam_hospital", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 12 + "level_3_lighting_definition_id": 12 }, { "lighting_space_type_name": "bam_hotel", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 13 + "level_3_lighting_definition_id": 13 }, { "lighting_space_type_name": "bam_library", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 14 + "level_3_lighting_definition_id": 14 }, { "lighting_space_type_name": "bam_manufacturing_facility", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 15 + "level_3_lighting_definition_id": 15 }, { "lighting_space_type_name": "bam_motel", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 13 + "level_3_lighting_definition_id": 13 }, { "lighting_space_type_name": "bam_motion_picture_theater", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 16 + "level_3_lighting_definition_id": 16 }, { "lighting_space_type_name": "bam_multifamily", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 17 + "level_3_lighting_definition_id": 17 }, { "lighting_space_type_name": "bam_museum", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 18 + "level_3_lighting_definition_id": 18 }, { "lighting_space_type_name": "bam_office", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 19 + "level_3_lighting_definition_id": 19 }, { "lighting_space_type_name": "bam_parking_garage", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 20 + "level_3_lighting_definition_id": 20 }, { "lighting_space_type_name": "bam_penitentiary", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 21 + "level_3_lighting_definition_id": 21 }, { "lighting_space_type_name": "bam_performing_arts_theater", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 22 + "level_3_lighting_definition_id": 22 }, { "lighting_space_type_name": "bam_police_station", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 23 + "level_3_lighting_definition_id": 23 }, { "lighting_space_type_name": "bam_post_office", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 24 + "level_3_lighting_definition_id": 24 }, { "lighting_space_type_name": "bam_religious_facility", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 25 + "level_3_lighting_definition_id": 25 }, { "lighting_space_type_name": "bam_retail", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 26 + "level_3_lighting_definition_id": 26 }, { "lighting_space_type_name": "bam_school_university", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 27 + "level_3_lighting_definition_id": 27 }, { "lighting_space_type_name": "bam_sports_arena", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 28 + "level_3_lighting_definition_id": 28 }, { "lighting_space_type_name": "bam_town_hall", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 29 + "level_3_lighting_definition_id": 29 }, { "lighting_space_type_name": "bam_transportation", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 30 + "level_3_lighting_definition_id": 30 }, { "lighting_space_type_name": "bam_warehouse", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 31 + "level_3_lighting_definition_id": 31 }, { "lighting_space_type_name": "bam_workshop", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 32 + "level_3_lighting_definition_id": 32 }, { "lighting_space_type_name": "office_enclosed_small", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 79 + "level_3_lighting_definition_id": 79 }, { "lighting_space_type_name": "office_enclosed_large", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 80 + "level_3_lighting_definition_id": 80 }, { "lighting_space_type_name": "office_open", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 81 + "level_3_lighting_definition_id": 81 }, { "lighting_space_type_name": "conference_meeting_multipurpose", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 48 + "level_3_lighting_definition_id": 48 }, { "lighting_space_type_name": "classroom_lecture_training_general", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 47 + "level_3_lighting_definition_id": 47 }, { "lighting_space_type_name": "classroom_lecture_training_penitentiary", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 46 + "level_3_lighting_definition_id": 46 }, { "lighting_space_type_name": "lobby_general", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 75 + "level_3_lighting_definition_id": 75 }, { "lighting_space_type_name": "lobby_hotel", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 72 + "level_3_lighting_definition_id": 72 }, { "lighting_space_type_name": "lobby_performing_arts_theater", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 74 + "level_3_lighting_definition_id": 74 }, { "lighting_space_type_name": "lobby_motion_picture_theater", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 73 + "level_3_lighting_definition_id": 73 }, { "lighting_space_type_name": "lobby_visually_impaired", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 70 + "level_3_lighting_definition_id": 70 }, { "lighting_space_type_name": "lobby_elevator", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 71 + "level_3_lighting_definition_id": 71 }, { "lighting_space_type_name": "audience_seating_general", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 43 + "level_3_lighting_definition_id": 43 }, { "lighting_space_type_name": "audience_seating_gymnasium", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 37 + "level_3_lighting_definition_id": 37 }, { "lighting_space_type_name": "audience_seating_exercise_center", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 43 + "level_3_lighting_definition_id": 43 }, { "lighting_space_type_name": "audience_seating_convention_center", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 43 + "level_3_lighting_definition_id": 43 }, { "lighting_space_type_name": "audience_seating_penitentiary", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 39 + "level_3_lighting_definition_id": 39 }, { "lighting_space_type_name": "audience_seating_religious_facility", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 41 + "level_3_lighting_definition_id": 41 }, { "lighting_space_type_name": "audience_seating_sports_arena", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 42 + "level_3_lighting_definition_id": 42 }, { "lighting_space_type_name": "audience_seating_performing_arts_theater", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 40 + "level_3_lighting_definition_id": 40 }, { "lighting_space_type_name": "audience_seating_motion_picture_theater", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 38 + "level_3_lighting_definition_id": 38 }, { "lighting_space_type_name": "audience_seating_transportation", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 43 + "level_3_lighting_definition_id": 43 }, { "lighting_space_type_name": "audience_seating_auditorium", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 36 + "level_3_lighting_definition_id": 36 }, { "lighting_space_type_name": "atrium_low", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 33 + "level_3_lighting_definition_id": 33 }, { "lighting_space_type_name": "atrium_medium", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 34 + "level_3_lighting_definition_id": 34 }, { "lighting_space_type_name": "atrium_high", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 35 + "level_3_lighting_definition_id": 35 }, { "lighting_space_type_name": "lounge_breakroom_general", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 78 + "level_3_lighting_definition_id": 78 }, { "lighting_space_type_name": "lounge_breakroom_healthcare_facility", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 77 + "level_3_lighting_definition_id": 77 }, { "lighting_space_type_name": "dining_general", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 61 + "level_3_lighting_definition_id": 61 }, { "lighting_space_type_name": "dining_penitentiary", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 56 + "level_3_lighting_definition_id": 56 }, { "lighting_space_type_name": "dining_hotel", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 61 + "level_3_lighting_definition_id": 61 }, { "lighting_space_type_name": "dining_motel", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 61 + "level_3_lighting_definition_id": 61 }, { "lighting_space_type_name": "dining_bar_lounge_leisure", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 58 + "level_3_lighting_definition_id": 58 }, { "lighting_space_type_name": "dining_family", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 60 + "level_3_lighting_definition_id": 60 }, { "lighting_space_type_name": "dining_cafeteria_fast_food", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 59 + "level_3_lighting_definition_id": 59 }, { "lighting_space_type_name": "dining_visually_impaired", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 57 + "level_3_lighting_definition_id": 57 }, { "lighting_space_type_name": "kitchen", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 64 + "level_3_lighting_definition_id": 64 }, { "lighting_space_type_name": "laboratory_classroom", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 66 + "level_3_lighting_definition_id": 66 }, { "lighting_space_type_name": "laboratory_all_other", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 67 + "level_3_lighting_definition_id": 67 }, { "lighting_space_type_name": "restroom_visually_impaired", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 84 + "level_3_lighting_definition_id": 84 }, { "lighting_space_type_name": "restroom_all_other", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 85 + "level_3_lighting_definition_id": 85 }, { "lighting_space_type_name": "performing_arts_dressing_room", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 120 + "level_3_lighting_definition_id": 120 }, { "lighting_space_type_name": "corridor_general", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 53 + "level_3_lighting_definition_id": 53 }, { "lighting_space_type_name": "corridor_hospital", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 52 + "level_3_lighting_definition_id": 52 }, { "lighting_space_type_name": "corridor_manufacturing_facility", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 53 + "level_3_lighting_definition_id": 53 }, { "lighting_space_type_name": "corridor_visually_impaired", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 51 + "level_3_lighting_definition_id": 51 }, { "lighting_space_type_name": "stairway", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 88 + "level_3_lighting_definition_id": 88 }, { "lighting_space_type_name": "stairwell", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 89 + "level_3_lighting_definition_id": 89 }, { "lighting_space_type_name": "storage_ all_other_small", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 90 + "level_3_lighting_definition_id": 90 }, { "lighting_space_type_name": "storage_ all_other_large", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 91 + "level_3_lighting_definition_id": 91 }, { "lighting_space_type_name": "storage_hospital_small", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 90 + "level_3_lighting_definition_id": 90 }, { "lighting_space_type_name": "storage_hospital_large", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 91 + "level_3_lighting_definition_id": 91 }, { "lighting_space_type_name": "electrical_mechanical", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 62 + "level_3_lighting_definition_id": 62 }, { "lighting_space_type_name": "workshop", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 93 + "level_3_lighting_definition_id": 93 }, { "lighting_space_type_name": "gymnasium_playing_area", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 101 + "level_3_lighting_definition_id": 101 }, { "lighting_space_type_name": "gymnasium_exercise_area", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 100 + "level_3_lighting_definition_id": 100 }, { "lighting_space_type_name": "courtroom", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 54 + "level_3_lighting_definition_id": 54 }, { "lighting_space_type_name": "confinement_cells", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 49 + "level_3_lighting_definition_id": 49 }, { "lighting_space_type_name": "emergency_vehicle_garage", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 63 + "level_3_lighting_definition_id": 63 }, { "lighting_space_type_name": "firestation_sleeping_quarters", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 99 + "level_3_lighting_definition_id": 99 }, { "lighting_space_type_name": "post_office_sorting_area", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 121 + "level_3_lighting_definition_id": 121 }, { "lighting_space_type_name": "exhibit_convention_center", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 97 + "level_3_lighting_definition_id": 97 }, { "lighting_space_type_name": "library_stacks", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 112 + "level_3_lighting_definition_id": 112 }, { "lighting_space_type_name": "library_reading", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 111 + "level_3_lighting_definition_id": 111 }, { "lighting_space_type_name": "recovery", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 110 + "level_3_lighting_definition_id": 110 }, { "lighting_space_type_name": "nurses_station", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 106 + "level_3_lighting_definition_id": 106 }, { "lighting_space_type_name": "exam_treatment", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 102 + "level_3_lighting_definition_id": 102 }, { "lighting_space_type_name": "pharmacy", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 83 + "level_3_lighting_definition_id": 83 }, { "lighting_space_type_name": "patient_room", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 108 + "level_3_lighting_definition_id": 108 }, { "lighting_space_type_name": "operating_room", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 107 + "level_3_lighting_definition_id": 107 }, { "lighting_space_type_name": "nursery", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 105 + "level_3_lighting_definition_id": 105 }, { "lighting_space_type_name": "medical_supply", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 104 + "level_3_lighting_definition_id": 104 }, { "lighting_space_type_name": "physical_therapy", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 109 + "level_3_lighting_definition_id": 109 }, { "lighting_space_type_name": "imaging", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 103 + "level_3_lighting_definition_id": 103 }, { "lighting_space_type_name": "laundry_washing", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 68 + "level_3_lighting_definition_id": 68 }, { "lighting_space_type_name": "automotive", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 96 + "level_3_lighting_definition_id": 96 }, { "lighting_space_type_name": "manufacturing_low_bay", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 117 + "level_3_lighting_definition_id": 117 }, { "lighting_space_type_name": "manufacturing_high_bay", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 116 + "level_3_lighting_definition_id": 116 }, { "lighting_space_type_name": "detailed_manufacuring", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 113 + "level_3_lighting_definition_id": 113 }, { "lighting_space_type_name": "manufacturing_equipment_room", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 114 + "level_3_lighting_definition_id": 114 }, { "lighting_space_type_name": "manufacturing_extra_high_bay", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 115 + "level_3_lighting_definition_id": 115 }, { "lighting_space_type_name": "guest_room", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 65 + "level_3_lighting_definition_id": 65 }, { "lighting_space_type_name": "dormitory_living_quarters", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 98 + "level_3_lighting_definition_id": 98 }, { "lighting_space_type_name": "museum_exhibit_area", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 118 + "level_3_lighting_definition_id": 118 }, { "lighting_space_type_name": "museum_restoration", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 119 + "level_3_lighting_definition_id": 119 }, { "lighting_space_type_name": "banking_activity", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 44 + "level_3_lighting_definition_id": 44 }, { "lighting_space_type_name": "worship_pulpit_choir_area", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 123 + "level_3_lighting_definition_id": 123 }, { "lighting_space_type_name": "fellowship_hall_religious_facility", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 122 + "level_3_lighting_definition_id": 122 }, { "lighting_space_type_name": "sales", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 86 + "level_3_lighting_definition_id": 86 }, { "lighting_space_type_name": "retail_mall_concourse", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 125 + "level_3_lighting_definition_id": 125 }, { "lighting_space_type_name": "retail_dressing_room", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 124 + "level_3_lighting_definition_id": 124 }, { "lighting_space_type_name": "sports_arena_playing_area_class_I", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 126 + "level_3_lighting_definition_id": 126 }, { "lighting_space_type_name": "sports_arena_playing_area_class_II", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 127 + "level_3_lighting_definition_id": 127 }, { "lighting_space_type_name": "sports_arena_playing_area_class_III", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 128 + "level_3_lighting_definition_id": 128 }, { "lighting_space_type_name": "sports_arena_playing_area_class_IV", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 129 + "level_3_lighting_definition_id": 129 }, { "lighting_space_type_name": "warehouse_fine_storage", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 134 + "level_3_lighting_definition_id": 134 }, { "lighting_space_type_name": "warehouse_bulk_storage", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 133 + "level_3_lighting_definition_id": 133 }, { "lighting_space_type_name": "parking_area_interior", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 82 + "level_3_lighting_definition_id": 82 }, { "lighting_space_type_name": "airport_concourse", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 131 + "level_3_lighting_definition_id": 131 }, { "lighting_space_type_name": "baggage_carousel", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 130 + "level_3_lighting_definition_id": 130 }, { "lighting_space_type_name": "transportation_ticket_counter", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 132 + "level_3_lighting_definition_id": 132 }, { "lighting_space_type_name": "sales_display_type_1", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 135 + "level_3_lighting_definition_id": 135 }, { "lighting_space_type_name": "sales_display_type_2", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 136 + "level_3_lighting_definition_id": 136 }, { "lighting_space_type_name": "sales_display_type_3", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 137 + "level_3_lighting_definition_id": 137 }, { "lighting_space_type_name": "sales_display_type_4", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 138 + "level_3_lighting_definition_id": 138 }, { "lighting_space_type_name": "breakroom", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 45 + "level_3_lighting_definition_id": 45 }, { "lighting_space_type_name": "copy_print", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 50 + "level_3_lighting_definition_id": 50 }, { "lighting_space_type_name": "computer_room", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 55 + "level_3_lighting_definition_id": 55 }, { "lighting_space_type_name": "loading_dock", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 69 + "level_3_lighting_definition_id": 69 }, { "lighting_space_type_name": "locker_room", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 76 + "level_3_lighting_definition_id": 76 }, { "lighting_space_type_name": "seating_area_general", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 87 + "level_3_lighting_definition_id": 87 }, { "lighting_space_type_name": "vehicular_maintenance", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 92 + "level_3_lighting_definition_id": 92 }, { "lighting_space_type_name": "chapel_visually_impaired", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 94 + "level_3_lighting_definition_id": 94 }, { "lighting_space_type_name": "recreation_common_living_visually_impaired", "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_defintion_id": 95 + "level_3_lighting_definition_id": 95 } ] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.csv b/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.csv index 9b99cdb8fb..910270163c 100644 --- a/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.csv +++ b/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.csv @@ -1,4 +1,4 @@ -ventilation_space_type_name,level_3_ventilation_definition_table,level_3_ventilation_defintion_id +ventilation_space_type_name,level_3_ventilation_definition_table,level_3_ventilation_definition_id correctional_facilities_cell,level_3_ventilation_90_1_2019,13 correctional_facilities_dayroom,level_3_ventilation_90_1_2019,14 correctional_facilities_guard_stations,level_3_ventilation_90_1_2019,15 diff --git a/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.json b/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.json index 47898183d4..7e51949c1a 100644 --- a/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.json +++ b/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.json @@ -2,866 +2,866 @@ { "ventilation_space_type_name": "correctional_facilities_cell", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 13 + "level_3_ventilation_definition_id": 13 }, { "ventilation_space_type_name": "correctional_facilities_dayroom", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 14 + "level_3_ventilation_definition_id": 14 }, { "ventilation_space_type_name": "correctional_facilities_guard_stations", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 15 + "level_3_ventilation_definition_id": 15 }, { "ventilation_space_type_name": "correctional_facilities_booking_waiting", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 12 + "level_3_ventilation_definition_id": 12 }, { "ventilation_space_type_name": "educational_facilities_daycare", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 21 + "level_3_ventilation_definition_id": 21 }, { "ventilation_space_type_name": "educational_facilities_classroom_young", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 17 + "level_3_ventilation_definition_id": 17 }, { "ventilation_space_type_name": "educational_facilities_classroom_old", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 18 + "level_3_ventilation_definition_id": 18 }, { "ventilation_space_type_name": "educational_facilities_lecture_classroom", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 22 + "level_3_ventilation_definition_id": 22 }, { "ventilation_space_type_name": "educational_facilities_lecture_hall", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 23 + "level_3_ventilation_definition_id": 23 }, { "ventilation_space_type_name": "educational_facilities_art_classroom", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 16 + "level_3_ventilation_definition_id": 16 }, { "ventilation_space_type_name": "educational_facilities_science_laboratories", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 28 + "level_3_ventilation_definition_id": 28 }, { "ventilation_space_type_name": "educational_facilities_wood_metal_shop", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 30 + "level_3_ventilation_definition_id": 30 }, { "ventilation_space_type_name": "educational_facilities_computer_lab", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 19 + "level_3_ventilation_definition_id": 19 }, { "ventilation_space_type_name": "educational_facilities_media_center", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 25 + "level_3_ventilation_definition_id": 25 }, { "ventilation_space_type_name": "educational_facilities_music_theater_dance", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 27 + "level_3_ventilation_definition_id": 27 }, { "ventilation_space_type_name": "educational_facilities_multiuse_assembly", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 26 + "level_3_ventilation_definition_id": 26 }, { "ventilation_space_type_name": "educational_facilities_daycare_sickroom", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 20 + "level_3_ventilation_definition_id": 20 }, { "ventilation_space_type_name": "educational_facilities_libraries", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 24 + "level_3_ventilation_definition_id": 24 }, { "ventilation_space_type_name": "educational_facilities_university_college_laboratories", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 29 + "level_3_ventilation_definition_id": 29 }, { "ventilation_space_type_name": "food_beverage_service_restaurant_dining_rooms", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 34 + "level_3_ventilation_definition_id": 34 }, { "ventilation_space_type_name": "food_beverage_service_cafeteria_fast_food_dining", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 32 + "level_3_ventilation_definition_id": 32 }, { "ventilation_space_type_name": "food_beverage_service_bars_cocktail_lounges", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 31 + "level_3_ventilation_definition_id": 31 }, { "ventilation_space_type_name": "food_beverage_service_kitchen", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 33 + "level_3_ventilation_definition_id": 33 }, { "ventilation_space_type_name": "general_conference_meeting", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 37 + "level_3_ventilation_definition_id": 37 }, { "ventilation_space_type_name": "general_conference_corridors", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 38 + "level_3_ventilation_definition_id": 38 }, { "ventilation_space_type_name": "general_conference_storage_rooms", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 39 + "level_3_ventilation_definition_id": 39 }, { "ventilation_space_type_name": "general_break_rooms", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 35 + "level_3_ventilation_definition_id": 35 }, { "ventilation_space_type_name": "general_coffee_stations", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 36 + "level_3_ventilation_definition_id": 36 }, { "ventilation_space_type_name": "hotels_motels_resorts_dormitories_bedroom_living_room", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 41 + "level_3_ventilation_definition_id": 41 }, { "ventilation_space_type_name": "hotels_motels_resorts_dormitories_barracks_sleeping_areas", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 40 + "level_3_ventilation_definition_id": 40 }, { "ventilation_space_type_name": "hotels_motels_resorts_dormitories_lobbies_prefunction", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 44 + "level_3_ventilation_definition_id": 44 }, { "ventilation_space_type_name": "hotels_motels_resorts_dormitories_multi_purpose_assembly", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 45 + "level_3_ventilation_definition_id": 45 }, { "ventilation_space_type_name": "hotels_motels_resorts_dormitories_laundry_rooms", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 42 + "level_3_ventilation_definition_id": 42 }, { "ventilation_space_type_name": "hotels_motels_resorts_dormitories_laundry_rooms_w_dwelling_units", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 43 + "level_3_ventilation_definition_id": 43 }, { "ventilation_space_type_name": "office_buildings_office_space", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 62 + "level_3_ventilation_definition_id": 62 }, { "ventilation_space_type_name": "office_buildings_reception_areas", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 63 + "level_3_ventilation_definition_id": 63 }, { "ventilation_space_type_name": "office_buildings_telephone_data_entry", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 64 + "level_3_ventilation_definition_id": 64 }, { "ventilation_space_type_name": "office_buildings_main_entry_lobbies", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 60 + "level_3_ventilation_definition_id": 60 }, { "ventilation_space_type_name": "office_buildings_breakrooms", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 59 + "level_3_ventilation_definition_id": 59 }, { "ventilation_space_type_name": "office_buildings_occupiable_storage_rooms", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 61 + "level_3_ventilation_definition_id": 61 }, { "ventilation_space_type_name": "miscellaneous_spaces_bank_ vaults_safe_deposit", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 47 + "level_3_ventilation_definition_id": 47 }, { "ventilation_space_type_name": "miscellaneous_spaces_computer", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 48 + "level_3_ventilation_definition_id": 48 }, { "ventilation_space_type_name": "miscellaneous_spaces_pharmacy", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 52 + "level_3_ventilation_definition_id": 52 }, { "ventilation_space_type_name": "miscellaneous_spaces_photo_studios", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 53 + "level_3_ventilation_definition_id": 53 }, { "ventilation_space_type_name": "miscellaneous_spaces_shipping_receiving", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 54 + "level_3_ventilation_definition_id": 54 }, { "ventilation_space_type_name": "miscellaneous_spaces_transportation_waiting", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 57 + "level_3_ventilation_definition_id": 57 }, { "ventilation_space_type_name": "miscellaneous_spaces_warehouses", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 58 + "level_3_ventilation_definition_id": 58 }, { "ventilation_space_type_name": "miscellaneous_spaces_banks_bank_lobbies", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 46 + "level_3_ventilation_definition_id": 46 }, { "ventilation_space_type_name": "miscellaneous_spaces_freezer_refrigerated_spaces", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 49 + "level_3_ventilation_definition_id": 49 }, { "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 50 + "level_3_ventilation_definition_id": 50 }, { "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_w_hazardous_materials", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 51 + "level_3_ventilation_definition_id": 51 }, { "ventilation_space_type_name": "miscellaneous_spaces_sorting_packing_light_assembly", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 55 + "level_3_ventilation_definition_id": 55 }, { "ventilation_space_type_name": "miscellaneous_spaces_telephone_closets", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 56 + "level_3_ventilation_definition_id": 56 }, { "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 83 + "level_3_ventilation_definition_id": 83 }, { "ventilation_space_type_name": "public_assembly_spaces_religious_workshop", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 90 + "level_3_ventilation_definition_id": 90 }, { "ventilation_space_type_name": "public_assembly_spaces_courtrooms", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 84 + "level_3_ventilation_definition_id": 84 }, { "ventilation_space_type_name": "public_assembly_spaces_legislative_chambers", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 85 + "level_3_ventilation_definition_id": 85 }, { "ventilation_space_type_name": "public_assembly_spaces_libraries", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 86 + "level_3_ventilation_definition_id": 86 }, { "ventilation_space_type_name": "public_assembly_spaces_lobbies", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 87 + "level_3_ventilation_definition_id": 87 }, { "ventilation_space_type_name": "public_assembly_spaces_children_museums", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 88 + "level_3_ventilation_definition_id": 88 }, { "ventilation_space_type_name": "public_assembly_spaces_museums_galleries", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 89 + "level_3_ventilation_definition_id": 89 }, { "ventilation_space_type_name": "retail_sales", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 91 + "level_3_ventilation_definition_id": 91 }, { "ventilation_space_type_name": "retail_mall_common_areas", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 95 + "level_3_ventilation_definition_id": 95 }, { "ventilation_space_type_name": "retail_barbershop", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 92 + "level_3_ventilation_definition_id": 92 }, { "ventilation_space_type_name": "retail_beauty_nail_salons", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 93 + "level_3_ventilation_definition_id": 93 }, { "ventilation_space_type_name": "retail_pet_shops", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 96 + "level_3_ventilation_definition_id": 96 }, { "ventilation_space_type_name": "retail_supermarket", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 97 + "level_3_ventilation_definition_id": 97 }, { "ventilation_space_type_name": "retail_coin_operated_laundries", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 94 + "level_3_ventilation_definition_id": 94 }, { "ventilation_space_type_name": "sports_entertainment_sports_arena", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 102 + "level_3_ventilation_definition_id": 102 }, { "ventilation_space_type_name": "sports_entertainment_gym_stadium", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 102 + "level_3_ventilation_definition_id": 102 }, { "ventilation_space_type_name": "sports_entertainment_spectator_areas", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 105 + "level_3_ventilation_definition_id": 105 }, { "ventilation_space_type_name": "sports_entertainment_swimming", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 107 + "level_3_ventilation_definition_id": 107 }, { "ventilation_space_type_name": "sports_entertainment_disco_dance_floors", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 99 + "level_3_ventilation_definition_id": 99 }, { "ventilation_space_type_name": "sports_entertainment_health_club_aerobics_room", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 103 + "level_3_ventilation_definition_id": 103 }, { "ventilation_space_type_name": "sports_entertainment_health_club_weight_rooms", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 104 + "level_3_ventilation_definition_id": 104 }, { "ventilation_space_type_name": "sports_entertainment_bowling_alley", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 98 + "level_3_ventilation_definition_id": 98 }, { "ventilation_space_type_name": "sports_entertainment_gambling_casinos", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 100 + "level_3_ventilation_definition_id": 100 }, { "ventilation_space_type_name": "sports_entertainment_game_arcades", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 101 + "level_3_ventilation_definition_id": 101 }, { "ventilation_space_type_name": "sports_entertainment_stages_studios", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 106 + "level_3_ventilation_definition_id": 106 }, { "ventilation_space_type_name": "animal_facilities_animal_exam_room", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 1 + "level_3_ventilation_definition_id": 1 }, { "ventilation_space_type_name": "animal_facilities_animal_imaging", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 2 + "level_3_ventilation_definition_id": 2 }, { "ventilation_space_type_name": "animal_facilities_animal_operating_rooms", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 3 + "level_3_ventilation_definition_id": 3 }, { "ventilation_space_type_name": "animal_facilities_animal_postoperative_recovery_room", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 4 + "level_3_ventilation_definition_id": 4 }, { "ventilation_space_type_name": "animal_facilities_animal_preparation_rooms", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 5 + "level_3_ventilation_definition_id": 5 }, { "ventilation_space_type_name": "animal_facilities_animal_procedure_room", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 6 + "level_3_ventilation_definition_id": 6 }, { "ventilation_space_type_name": "animal_facilities_animal_surgery_scrub", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 7 + "level_3_ventilation_definition_id": 7 }, { "ventilation_space_type_name": "animal_facilities_large_animal_holding_room", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 8 + "level_3_ventilation_definition_id": 8 }, { "ventilation_space_type_name": "animal_facilities_necropsy", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 9 + "level_3_ventilation_definition_id": 9 }, { "ventilation_space_type_name": "animal_facilities_small_animal_cage_room_static", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 10 + "level_3_ventilation_definition_id": 10 }, { "ventilation_space_type_name": "animal_facilities_small_animal_cage_room_ventilated", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 11 + "level_3_ventilation_definition_id": 11 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_birthing_room", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 65 + "level_3_ventilation_definition_id": 65 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_class_1_imaging_rooms", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 66 + "level_3_ventilation_definition_id": 66 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_dental_operatory", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 67 + "level_3_ventilation_definition_id": 67 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_general_examination_room", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 68 + "level_3_ventilation_definition_id": 68 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_other_dental_treatment_areas", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 69 + "level_3_ventilation_definition_id": 69 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_physical_therapy_exercise_area", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 70 + "level_3_ventilation_definition_id": 70 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_physical_therapy_individual_room", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 71 + "level_3_ventilation_definition_id": 71 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_physical_therapeutic_pool_area", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 72 + "level_3_ventilation_definition_id": 72 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_prosthetics_orthotics_room", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 73 + "level_3_ventilation_definition_id": 73 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_psychiatric_consultation_room", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 74 + "level_3_ventilation_definition_id": 74 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_psychiatric_examination_room", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 75 + "level_3_ventilation_definition_id": 75 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_psychiatric_group_room", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 76 + "level_3_ventilation_definition_id": 76 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_psychiatric_seclusion_room", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 77 + "level_3_ventilation_definition_id": 77 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_speech_therapy_room", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 78 + "level_3_ventilation_definition_id": 78 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_urgent_care_examination_room", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 79 + "level_3_ventilation_definition_id": 79 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_urgent_care_observation_room", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 80 + "level_3_ventilation_definition_id": 80 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_urgent_care_treatment_room", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 81 + "level_3_ventilation_definition_id": 81 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_urgent_care_triage_room", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 82 + "level_3_ventilation_definition_id": 82 }, { "ventilation_space_type_name": "transient_residential_common_corridors", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 108 + "level_3_ventilation_definition_id": 108 }, { "ventilation_space_type_name": "transient_residential_dwelling_unit", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", - "level_3_ventilation_defintion_id": 109 + "level_3_ventilation_definition_id": 109 }, { "ventilation_space_type_name": "correctional_facilities_cell", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 1 + "level_3_ventilation_definition_id": 1 }, { "ventilation_space_type_name": "correctional_facilities_dayroom", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 2 + "level_3_ventilation_definition_id": 2 }, { "ventilation_space_type_name": "correctional_facilities_guard_stations", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 3 + "level_3_ventilation_definition_id": 3 }, { "ventilation_space_type_name": "correctional_facilities_booking_waiting", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 4 + "level_3_ventilation_definition_id": 4 }, { "ventilation_space_type_name": "educational_facilities_daycare", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 5 + "level_3_ventilation_definition_id": 5 }, { "ventilation_space_type_name": "educational_facilities_classroom_young", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 6 + "level_3_ventilation_definition_id": 6 }, { "ventilation_space_type_name": "educational_facilities_classroom_old", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 7 + "level_3_ventilation_definition_id": 7 }, { "ventilation_space_type_name": "educational_facilities_lecture_classroom", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 8 + "level_3_ventilation_definition_id": 8 }, { "ventilation_space_type_name": "educational_facilities_lecture_hall", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 9 + "level_3_ventilation_definition_id": 9 }, { "ventilation_space_type_name": "educational_facilities_art_classroom", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 10 + "level_3_ventilation_definition_id": 10 }, { "ventilation_space_type_name": "educational_facilities_science_laboratories", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 11 + "level_3_ventilation_definition_id": 11 }, { "ventilation_space_type_name": "educational_facilities_wood_metal_shop", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 12 + "level_3_ventilation_definition_id": 12 }, { "ventilation_space_type_name": "educational_facilities_computer_lab", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 13 + "level_3_ventilation_definition_id": 13 }, { "ventilation_space_type_name": "educational_facilities_media_center", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 14 + "level_3_ventilation_definition_id": 14 }, { "ventilation_space_type_name": "educational_facilities_music_theater_dance", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 15 + "level_3_ventilation_definition_id": 15 }, { "ventilation_space_type_name": "educational_facilities_multiuse_assembly", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 16 + "level_3_ventilation_definition_id": 16 }, { "ventilation_space_type_name": "food_beverage_service_restaurant_dining_rooms", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 17 + "level_3_ventilation_definition_id": 17 }, { "ventilation_space_type_name": "food_beverage_service_cafeteria_fast_food_dining", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 18 + "level_3_ventilation_definition_id": 18 }, { "ventilation_space_type_name": "food_beverage_service_bars_cocktail_lounges", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 19 + "level_3_ventilation_definition_id": 19 }, { "ventilation_space_type_name": "general_conference_meeting", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 20 + "level_3_ventilation_definition_id": 20 }, { "ventilation_space_type_name": "general_conference_corridors", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 21 + "level_3_ventilation_definition_id": 21 }, { "ventilation_space_type_name": "general_conference_storage_rooms", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 22 + "level_3_ventilation_definition_id": 22 }, { "ventilation_space_type_name": "hotels_motels_resorts_dormitories_bedroom_living_room", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 23 + "level_3_ventilation_definition_id": 23 }, { "ventilation_space_type_name": "hotels_motels_resorts_dormitories_barracks_sleeping_areas", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 24 + "level_3_ventilation_definition_id": 24 }, { "ventilation_space_type_name": "hotels_motels_resorts_dormitories_lobbies_prefunction", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 25 + "level_3_ventilation_definition_id": 25 }, { "ventilation_space_type_name": "hotels_motels_resorts_dormitories_multi_purpose_assembly", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 26 + "level_3_ventilation_definition_id": 26 }, { "ventilation_space_type_name": "office_buildings_office_space", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 27 + "level_3_ventilation_definition_id": 27 }, { "ventilation_space_type_name": "office_buildings_reception_areas", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 28 + "level_3_ventilation_definition_id": 28 }, { "ventilation_space_type_name": "office_buildings_telephone_data_entry", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 29 + "level_3_ventilation_definition_id": 29 }, { "ventilation_space_type_name": "office_buildings_main_entry_lobbies", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 30 + "level_3_ventilation_definition_id": 30 }, { "ventilation_space_type_name": "miscellaneous_spaces_bank_ vaults_safe_deposit", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 31 + "level_3_ventilation_definition_id": 31 }, { "ventilation_space_type_name": "miscellaneous_spaces_computer", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 32 + "level_3_ventilation_definition_id": 32 }, { "ventilation_space_type_name": "miscellaneous_spaces_pharmacy", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 33 + "level_3_ventilation_definition_id": 33 }, { "ventilation_space_type_name": "miscellaneous_spaces_photo_studios", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 34 + "level_3_ventilation_definition_id": 34 }, { "ventilation_space_type_name": "miscellaneous_spaces_shipping_receiving", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 35 + "level_3_ventilation_definition_id": 35 }, { "ventilation_space_type_name": "miscellaneous_spaces_transportation_waiting", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 36 + "level_3_ventilation_definition_id": 36 }, { "ventilation_space_type_name": "miscellaneous_spaces_warehouses", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 37 + "level_3_ventilation_definition_id": 37 }, { "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 38 + "level_3_ventilation_definition_id": 38 }, { "ventilation_space_type_name": "public_assembly_spaces_religious_workshop", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 39 + "level_3_ventilation_definition_id": 39 }, { "ventilation_space_type_name": "public_assembly_spaces_courtrooms", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 40 + "level_3_ventilation_definition_id": 40 }, { "ventilation_space_type_name": "public_assembly_spaces_legislative_chambers", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 41 + "level_3_ventilation_definition_id": 41 }, { "ventilation_space_type_name": "public_assembly_spaces_libraries", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 42 + "level_3_ventilation_definition_id": 42 }, { "ventilation_space_type_name": "public_assembly_spaces_lobbies", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 43 + "level_3_ventilation_definition_id": 43 }, { "ventilation_space_type_name": "public_assembly_spaces_children_museums", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 44 + "level_3_ventilation_definition_id": 44 }, { "ventilation_space_type_name": "public_assembly_spaces_museums_galleries", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 45 + "level_3_ventilation_definition_id": 45 }, { "ventilation_space_type_name": "retail_sales", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 46 + "level_3_ventilation_definition_id": 46 }, { "ventilation_space_type_name": "retail_mall_common_areas", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 47 + "level_3_ventilation_definition_id": 47 }, { "ventilation_space_type_name": "retail_barbershop", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 48 + "level_3_ventilation_definition_id": 48 }, { "ventilation_space_type_name": "retail_beauty_nail_salons", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 49 + "level_3_ventilation_definition_id": 49 }, { "ventilation_space_type_name": "retail_pet_shops", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 50 + "level_3_ventilation_definition_id": 50 }, { "ventilation_space_type_name": "retail_supermarket", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 51 + "level_3_ventilation_definition_id": 51 }, { "ventilation_space_type_name": "retail_coin_operated_laundries", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 52 + "level_3_ventilation_definition_id": 52 }, { "ventilation_space_type_name": "sports_entertainment_sports_arena", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 53 + "level_3_ventilation_definition_id": 53 }, { "ventilation_space_type_name": "sports_entertainment_gym_stadium", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 54 + "level_3_ventilation_definition_id": 54 }, { "ventilation_space_type_name": "sports_entertainment_spectator_areas", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 55 + "level_3_ventilation_definition_id": 55 }, { "ventilation_space_type_name": "sports_entertainment_swimming", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 56 + "level_3_ventilation_definition_id": 56 }, { "ventilation_space_type_name": "sports_entertainment_disco_dance_floors", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 57 + "level_3_ventilation_definition_id": 57 }, { "ventilation_space_type_name": "sports_entertainment_health_club_aerobics_room", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 58 + "level_3_ventilation_definition_id": 58 }, { "ventilation_space_type_name": "sports_entertainment_health_club_weight_rooms", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 59 + "level_3_ventilation_definition_id": 59 }, { "ventilation_space_type_name": "sports_entertainment_bowling_alley", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 60 + "level_3_ventilation_definition_id": 60 }, { "ventilation_space_type_name": "sports_entertainment_gambling_casinos", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 61 + "level_3_ventilation_definition_id": 61 }, { "ventilation_space_type_name": "sports_entertainment_game_arcades", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 62 + "level_3_ventilation_definition_id": 62 }, { "ventilation_space_type_name": "sports_entertainment_stages_studios", "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", - "level_3_ventilation_defintion_id": 63 + "level_3_ventilation_definition_id": 63 } ] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py b/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py index 6b2932d3e4..4dd41bdb1a 100644 --- a/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py +++ b/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py @@ -7,7 +7,7 @@ Must provide a tuple that contains: lighting_space_type_name: TEXT (unique) level_3_lighting_definition_table: TEXT -level_3_lighting_defintion_id: id from level_3_lighting_definition index +level_3_lighting_definition_id: id from level_3_lighting_definition index """ LIGHT_SUBSPACE_TABLE = """ @@ -15,21 +15,21 @@ (id INTEGER PRIMARY KEY, lighting_space_type_name TEXT NOT NULL, level_3_lighting_definition_table TEXT NOT NULL, -level_3_lighting_defintion_id INTEGER NOT NULL, +level_3_lighting_definition_id INTEGER NOT NULL, FOREIGN KEY(lighting_space_type_name) REFERENCES support_lighting_space_type_name_tags(lighting_space_type_name) ); """ INSERT_LIGHT_SUBSPACE = f""" INSERT INTO {TABLE_NAME} - (lighting_space_type_name, level_3_lighting_definition_table, level_3_lighting_defintion_id) + (lighting_space_type_name, level_3_lighting_definition_table, level_3_lighting_definition_id) VALUES (?, ?, ?); """ RECORD_TEMPLATE = { "lighting_space_type_name": "", "level_3_lighting_definition_table": "", - "level_3_lighting_defintion_id": "", + "level_3_lighting_definition_id": "", } @@ -57,7 +57,7 @@ def _preprocess_record(self, record): record_list = ( getattr_either("lighting_space_type_name", record), getattr_either("level_3_lighting_definition_table", record), - getattr_either("level_3_lighting_defintion_id", record), + getattr_either("level_3_lighting_definition_id", record), ) return record_list diff --git a/data/openstudio_standards_data/database_tables/level_2_ventilation_space_types.py b/data/openstudio_standards_data/database_tables/level_2_ventilation_space_types.py index 622e78aca5..fd73af3240 100644 --- a/data/openstudio_standards_data/database_tables/level_2_ventilation_space_types.py +++ b/data/openstudio_standards_data/database_tables/level_2_ventilation_space_types.py @@ -7,7 +7,7 @@ Must provide a tuple that contains: ventilation_space_type_name: TEXT (unique) level_3_ventilation_definition_table: TEXT -level_3_ventilation_defintion_id: id from level_3_ventilation_definition index +level_3_ventilation_definition_id: id from level_3_ventilation_definition index """ VENT_SUBSPACE_TABLE = """ @@ -15,7 +15,7 @@ (id INTEGER PRIMARY KEY, ventilation_space_type_name TEXT NOT NULL, level_3_ventilation_definition_table TEXT NOT NULL, -level_3_ventilation_defintion_id INTEGER NOT NULL, +level_3_ventilation_definition_id INTEGER NOT NULL, FOREIGN KEY(ventilation_space_type_name) REFERENCES support_ventilation_space_type_name_tags(ventilation_space_type_name) ); @@ -23,14 +23,14 @@ INSERT_VENT_SUBSPACE = f""" INSERT INTO {TABLE_NAME} - (ventilation_space_type_name, level_3_ventilation_definition_table, level_3_ventilation_defintion_id) + (ventilation_space_type_name, level_3_ventilation_definition_table, level_3_ventilation_definition_id) VALUES (?, ?, ?); """ RECORD_TEMPLATE = { "ventilation_space_type_name": "", "level_3_ventilation_definition_table": "", - "level_3_ventilation_defintion_id": "", + "level_3_ventilation_definition_id": "", } @@ -59,7 +59,7 @@ def _preprocess_record(self, record): record_list = ( getattr_either("ventilation_space_type_name", record), getattr_either("level_3_ventilation_definition_table", record), - getattr_either("level_3_ventilation_defintion_id", record), + getattr_either("level_3_ventilation_definition_id", record), ) return record_list diff --git a/data/openstudio_standards_data/query/fetch/space.py b/data/openstudio_standards_data/query/fetch/space.py index 3739ab8e10..c88222468c 100644 --- a/data/openstudio_standards_data/query/fetch/space.py +++ b/data/openstudio_standards_data/query/fetch/space.py @@ -11,9 +11,9 @@ "lighting_space_type_name", "ventilation_space_type_name", "level_3_lighting_definition_table", - "level_3_lighting_defintion_id", + "level_3_lighting_definition_id", "level_3_ventilation_definition_table", - "level_3_ventilation_defintion_id", + "level_3_ventilation_definition_id", "electric_equipment_space_type_name", ] From 38e8d4bfa2cc1c7ee5dfbd148f31bb64adb1934b Mon Sep 17 00:00:00 2001 From: Weili Xu Date: Tue, 28 Mar 2023 09:47:16 -0700 Subject: [PATCH 09/45] add validation for weak foreign key validation. --- .../database_engine/database.py | 42 ++++++++++++++++--- .../level_2_lighting_space_types.py | 6 +++ .../level_2_ventilation_space_types.py | 6 +++ data/openstudio_standards_data/query/util.py | 17 ++++++++ 4 files changed, 66 insertions(+), 5 deletions(-) diff --git a/data/openstudio_standards_data/database_engine/database.py b/data/openstudio_standards_data/database_engine/database.py index 167181e9bd..ffa347650e 100644 --- a/data/openstudio_standards_data/database_engine/database.py +++ b/data/openstudio_standards_data/database_engine/database.py @@ -4,6 +4,8 @@ import json import logging +from query.util import is_index_in_table + DB_FILE = "openstudio_standards_database.db" @@ -54,11 +56,12 @@ def add_a_record(self, connection, record: dict): """ # run data validation, raise exception if data is not validated. cur = connection.cursor() - - self.validate_record_datatype(record) - cur.execute(self._get_insert_record_query(), self._preprocess_record(record)) - connection.commit() - return cur.lastrowid + success_added = False + if self.validate_record_datatype(record) and self.validate_weak_foreign_key(record): + cur.execute(self._get_insert_record_query(), self._preprocess_record(record)) + connection.commit() + success_added = True + return success_added def get_all_records(self, connection): """ @@ -93,6 +96,21 @@ def validate_record_datatype(self, record): """ return True + def validate_weak_foreign_key(self, conn, record): + """ + Validate if a key is existing in a weak associated table. The definition of weak associate table in OSSTD + means when the primary key in a table is referenced by another table in a column instead of SQL foriegn key + relationship. An example is the level_2_lighting_space_type contains level_3_lighting_definition_id that + references an index from the table specified in the column level_3_lighting_definition_table. + For weak foreign key, we will use this function to determine whether it is correct addition or update. + + :param: conn, SQL3lite connection + :param: record: dictionary + """ + associate_table, key, value = self._get_weak_foreign_key_value(record) + # any value is Falsy (no association) should return True, or pass the is_index_in_table check. + return not all([associate_table, key, value]) or is_index_in_table(conn, associate_table, key, value) + def export_table_to_csv(self, conn, save_dir=""): """ A function that exports the table into a .csv file @@ -136,6 +154,19 @@ def export_table_to_json(self, conn, save_dir=""): with open(json_dir, "w", newline="\r\n") as json_file: json_file.write(json_output) + # Functions to be overridden based on need + def _get_weak_foreign_key_value(self, record): + """ + Function to extract values from a record for weak foreign key validation + :param record: dictionary + :return + associate_table: str - table that has weak foreign cooneciton + key: the foreign key + value: the foreign key value + default are NONE (falsy) + """ + return None, None, None + def _preprocess_record(self, record): """ Function that pre-process a record before insert to Table. @@ -165,3 +196,4 @@ def _get_retrieve_all_query(self): :return: """ return f"SELECT * FROM {self.data_table_name}" + diff --git a/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py b/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py index 4dd41bdb1a..5c8a0d4dc9 100644 --- a/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py +++ b/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py @@ -48,6 +48,12 @@ def get_record_info(self): """ return RECORD_HELP + def _get_weak_foreign_key_value(self, record): + associate_table = getattr_either("level_3_lighting_definition_table", record), + key = "id" + value = getattr_either("level_3_lighting_definition_id", record), + return associate_table, key, value + def _preprocess_record(self, record): """ diff --git a/data/openstudio_standards_data/database_tables/level_2_ventilation_space_types.py b/data/openstudio_standards_data/database_tables/level_2_ventilation_space_types.py index fd73af3240..e47001f5ab 100644 --- a/data/openstudio_standards_data/database_tables/level_2_ventilation_space_types.py +++ b/data/openstudio_standards_data/database_tables/level_2_ventilation_space_types.py @@ -49,6 +49,12 @@ def get_record_info(self): """ return RECORD_HELP + def _get_weak_foreign_key_value(self, record): + associate_table = getattr_either("level_3_ventilation_definition_table", record), + key = "id" + value = getattr_either("level_3_ventilation_definition_id", record), + return associate_table, key, value + def _preprocess_record(self, record): """ diff --git a/data/openstudio_standards_data/query/util.py b/data/openstudio_standards_data/query/util.py index 507eb51099..05956bb30c 100644 --- a/data/openstudio_standards_data/query/util.py +++ b/data/openstudio_standards_data/query/util.py @@ -22,6 +22,23 @@ def _convert_tuple_to_dict(data: tuple, data_head_list: List[str]): return dict(zip(data_head_list, data)) +def is_index_in_table(conn: sqlite3.Connection, table_name: str, key: str, index: str): + """ + Utility function to ensure the index exist in a table. + :param conn: sqlite3 connection + :param table_name: string, a table's name + :param key: string, the foreign key name + :param index: integer, a table's index, primary key + :return: True if index is in table, False otherwise. + """ + result = None + cursor = conn.cursor() + if is_table_exist(conn, table_name): + cursor.execute(f"SELECT id FROM {table_name} WHERE {key} = ?", (index,)) + result = cursor.fetchone() + return True if result else False + + def is_table_exist(conn: sqlite3.Connection, table_name): """ Utility function to ensure the table name provided is correct and exist in the openstudio_standards data tables From f885ec11b5b0ad96d87c95348238dcdd93ab430e Mon Sep 17 00:00:00 2001 From: Weili Xu Date: Tue, 28 Mar 2023 09:49:25 -0700 Subject: [PATCH 10/45] update to include None check --- data/openstudio_standards_data/query/util.py | 12 +++++++----- 1 file changed, 7 insertions(+), 5 deletions(-) diff --git a/data/openstudio_standards_data/query/util.py b/data/openstudio_standards_data/query/util.py index 05956bb30c..6d04e95a6a 100644 --- a/data/openstudio_standards_data/query/util.py +++ b/data/openstudio_standards_data/query/util.py @@ -22,7 +22,7 @@ def _convert_tuple_to_dict(data: tuple, data_head_list: List[str]): return dict(zip(data_head_list, data)) -def is_index_in_table(conn: sqlite3.Connection, table_name: str, key: str, index: str): +def is_index_in_table(conn: sqlite3.Connection, table_name: str | None, key: str | None, index: str | None): """ Utility function to ensure the index exist in a table. :param conn: sqlite3 connection @@ -32,10 +32,12 @@ def is_index_in_table(conn: sqlite3.Connection, table_name: str, key: str, index :return: True if index is in table, False otherwise. """ result = None - cursor = conn.cursor() - if is_table_exist(conn, table_name): - cursor.execute(f"SELECT id FROM {table_name} WHERE {key} = ?", (index,)) - result = cursor.fetchone() + # Make sure no value is None + if all([table_name, key, index]): + cursor = conn.cursor() + if is_table_exist(conn, table_name): + cursor.execute(f"SELECT id FROM {table_name} WHERE {key} = ?", (index,)) + result = cursor.fetchone() return True if result else False From a4717494f0af2e8aaf33e9653ca729182dbe8379 Mon Sep 17 00:00:00 2001 From: Weili Xu Date: Tue, 28 Mar 2023 11:03:07 -0700 Subject: [PATCH 11/45] move create script and insert script to class constructor. Build test case for the index validation Complete the workflow --- .../database_engine/database.py | 28 ++--- .../database_tables/envelope_requirement.py | 18 ++- .../hvac_minimum_requirement_boilers.py | 8 +- .../hvac_minimum_requirement_chillers.py | 7 +- .../hvac_minimum_requirement_furnaces.py | 8 +- ...c_minimum_requirement_heat_pump_cooling.py | 7 +- ...c_minimum_requirement_heat_pump_heating.py | 8 +- ...hvac_minimum_requirement_heat_rejection.py | 7 +- .../hvac_minimum_requirement_motors.py | 6 +- ...um_requirement_unitary_air_conditioners.py | 11 +- .../hvac_minimum_requirement_water_heaters.py | 8 +- ...irement_water_source_heat_pumps_cooling.py | 11 +- ...irement_water_source_heat_pumps_heating.py | 10 +- .../database_tables/level_1_space_types.py | 16 +-- .../level_2_electric_equipment.py | 10 +- .../level_2_lighting_space_types.py | 13 +- .../level_2_ventilation_space_types.py | 13 +- .../level_3_lighting_90_1_definition.py | 7 +- .../level_3_ventilation_62_1_definition.py | 7 +- .../database_tables/support_constructions.py | 11 +- ...electric_equipment_space_type_name_tags.py | 14 +-- .../support_lighting_space_type_name_tags.py | 11 +- .../database_tables/support_materials.py | 12 +- .../support_performance_curves.py | 11 +- .../support_standard_templates.py | 13 +- ...upport_ventilation_space_type_name_tags.py | 13 +- .../system_requirement_economizer.py | 8 +- .../system_requirement_energy_recovery.py | 7 +- .../test/test_database.py | 111 ++++++++++++++---- 29 files changed, 188 insertions(+), 226 deletions(-) diff --git a/data/openstudio_standards_data/database_engine/database.py b/data/openstudio_standards_data/database_engine/database.py index ffa347650e..aa48f0adaf 100644 --- a/data/openstudio_standards_data/database_engine/database.py +++ b/data/openstudio_standards_data/database_engine/database.py @@ -26,16 +26,20 @@ def create_connect(db_file): class DBOperation: - def __init__(self, table_name, record_template, initial_data_directory): + def __init__(self, table_name, record_template, initial_data_directory, create_table_query, insert_record_query): """ DB Operation class :param table_name: String name of the table :param record_template: dictionary record template :param initial_data_directory: String initial data directory + :param create_table_query: String create table query + :param insert_record_query: String insert record query """ self.data_table_name = table_name self.record_template = record_template self.initial_data_directory = initial_data_directory + self.create_table_query = create_table_query + self.insert_record_query = insert_record_query def create_a_table(self, connection): """ @@ -44,7 +48,7 @@ def create_a_table(self, connection): :return: """ logging.info(f"creating table: {self.data_table_name}") - connection.execute(self._get_create_table_query()) + connection.execute(self.create_table_query) return True def add_a_record(self, connection, record: dict): @@ -57,8 +61,8 @@ def add_a_record(self, connection, record: dict): # run data validation, raise exception if data is not validated. cur = connection.cursor() success_added = False - if self.validate_record_datatype(record) and self.validate_weak_foreign_key(record): - cur.execute(self._get_insert_record_query(), self._preprocess_record(record)) + if self.validate_record_datatype(record) and self.validate_weak_foreign_key(connection, record): + cur.execute(self.insert_record_query, self._preprocess_record(record)) connection.commit() success_added = True return success_added @@ -174,21 +178,7 @@ def _preprocess_record(self, record): :param record: :return: """ - pass - - def _get_create_table_query(self): - """ - Function to create a table - :return: - """ - pass - - def _get_insert_record_query(self): - """ - Function to insert a query - :return: - """ - pass + return record def _get_retrieve_all_query(self): """ diff --git a/data/openstudio_standards_data/database_tables/envelope_requirement.py b/data/openstudio_standards_data/database_tables/envelope_requirement.py index 82ee41f1a6..48efd6c23d 100644 --- a/data/openstudio_standards_data/database_tables/envelope_requirement.py +++ b/data/openstudio_standards_data/database_tables/envelope_requirement.py @@ -1,3 +1,4 @@ +from database_engine.assertions import assert_ from database_engine.database import DBOperation from database_engine.database_util import is_float, getattr_either @@ -98,6 +99,8 @@ def __init__(self): table_name=TABLE_NAME, record_template=RECORD_TEMPLATE, initial_data_directory=f"database_files/{TABLE_NAME}", + create_table_query=CREATE_ENVELOPE_REQUIREMENTS_TABLE % TABLE_NAME, + insert_record_query=INSERT_A_ENVELOPE_REQUIREMENT_RECORD % TABLE_NAME ) def get_record_info(self): @@ -122,9 +125,9 @@ def validate_record_datatype(self, record): for f in str_expected: if record.get(f): - assert isinstance( + assert_(isinstance( record[f], str - ), f"{f} requires to be a string, instead got {record[f]}" + ), f"{f} requires to be a string, instead got {record[f]}") float_expected = [ "minimum_percent_of_surface", @@ -138,9 +141,10 @@ def validate_record_datatype(self, record): for f in float_expected: if record.get(f): - assert is_float( + assert_(is_float( record.get(f) - ), f"{f} requires to be numeric data type, instead got {record[f]}" + ), f"{f} requires to be numeric data type, instead got {record[f]}") + return True def _preprocess_record(self, record): """ @@ -168,9 +172,3 @@ def _preprocess_record(self, record): getattr_either("assembly_minimum_vt_shgc", record), getattr_either("annotation", record), ) - - def _get_create_table_query(self): - return CREATE_ENVELOPE_REQUIREMENTS_TABLE % self.data_table_name - - def _get_insert_record_query(self): - return INSERT_A_ENVELOPE_REQUIREMENT_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_boilers.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_boilers.py index 5f65a8408a..96242adf8b 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_boilers.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_boilers.py @@ -82,6 +82,8 @@ def __init__(self, table_name, initial_data_directory): table_name=table_name, record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, + create_table_query=CREATE_HVAC_REQ_BOILER_TABLE % table_name, + insert_record_query=INSERT_A_BOILER_RECORD % table_name ) def get_record_info(self): @@ -144,9 +146,3 @@ def _preprocess_record(self, record): getattr_either("efffplr", record), getattr_either("annotation", record, ""), ) - - def _get_create_table_query(self): - return CREATE_HVAC_REQ_BOILER_TABLE % self.data_table_name - - def _get_insert_record_query(self): - return INSERT_A_BOILER_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_chillers.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_chillers.py index a1d4f1c58f..e9d874f41b 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_chillers.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_chillers.py @@ -90,6 +90,8 @@ def __init__(self, table_name, initial_data_directory): table_name=table_name, record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, + create_table_query=CREATE_HVAC_REQUIREMENT_CHILLERS_TABLE % table_name, + insert_record_query=INSERT_A_CHILLER_RECORD % table_name ) def get_record_info(self): @@ -159,8 +161,3 @@ def _preprocess_record(self, record): getattr_either("annotation", record), ) - def _get_create_table_query(self): - return CREATE_HVAC_REQUIREMENT_CHILLERS_TABLE % self.data_table_name - - def _get_insert_record_query(self): - return INSERT_A_CHILLER_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_furnaces.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_furnaces.py index 56cc2374c2..d596c26ef4 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_furnaces.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_furnaces.py @@ -62,6 +62,8 @@ def __init__(self, table_name, initial_data_directory): table_name=table_name, record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, + create_table_query=CREATE_HVAC_REQUIREMENT_FURNACES_TABLE % table_name, + insert_record_query=INSERT_A_FURNACE_RECORD % table_name ) def get_record_info(self): @@ -116,9 +118,3 @@ def _preprocess_record(self, record): getattr_either("minimum_combustion_efficiency", record), getattr_either("annotation", record), ) - - def _get_create_table_query(self): - return CREATE_HVAC_REQUIREMENT_FURNACES_TABLE % self.data_table_name - - def _get_insert_record_query(self): - return INSERT_A_FURNACE_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_cooling.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_cooling.py index ff2d4b5298..28ffae193a 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_cooling.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_cooling.py @@ -106,6 +106,8 @@ def __init__(self, table_name, initial_data_directory): table_name=table_name, record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, + create_table_query=CREATE_HVAC_REQUIREMENT_HEAT_PUMP_COOLING_TABLE % table_name, + insert_record_query=INSERT_A_HEAT_PUMP_COOLING_RECORD % table_name ) def get_record_info(self): @@ -183,8 +185,3 @@ def _preprocess_record(self, record): getattr_either("annotation", record), ) - def _get_create_table_query(self): - return CREATE_HVAC_REQUIREMENT_HEAT_PUMP_COOLING_TABLE % self.data_table_name - - def _get_insert_record_query(self): - return INSERT_A_HEAT_PUMP_COOLING_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_heating.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_heating.py index 717657af49..499de7fa6a 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_heating.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_heating.py @@ -98,6 +98,8 @@ def __init__(self, table_name, initial_data_directory): table_name=table_name, record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, + create_table_query=CREATE_HVAC_REQUIREMENT_HEAT_PUMP_HEATING_TABLE % table_name, + insert_record_query=INSERT_A_HEAT_PUMP_HEATING_RECORD % table_name ) def get_record_info(self): @@ -170,9 +172,3 @@ def _preprocess_record(self, record): getattr_either("heat_plf_fplr", record), getattr_either("annotation", record), ) - - def _get_create_table_query(self): - return CREATE_HVAC_REQUIREMENT_HEAT_PUMP_HEATING_TABLE % self.data_table_name - - def _get_insert_record_query(self): - return INSERT_A_HEAT_PUMP_HEATING_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_rejection.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_rejection.py index 51cc7a1759..293db683b0 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_rejection.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_rejection.py @@ -54,6 +54,8 @@ def __init__(self, table_name, initial_data_directory): table_name=table_name, record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, + create_table_query=CREATE_HVAC_REQUIREMENT_HEAT_REJECTION_TABLE % table_name, + insert_record_query=INSERT_A_HEAT_REJECTION_RECORD % table_name ) def get_record_info(self): @@ -100,8 +102,3 @@ def _preprocess_record(self, record): getattr_either("annotation", record), ) - def _get_create_table_query(self): - return CREATE_HVAC_REQUIREMENT_HEAT_REJECTION_TABLE % self.data_table_name - - def _get_insert_record_query(self): - return INSERT_A_HEAT_REJECTION_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_motors.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_motors.py index bbccd02722..04c1236ce0 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_motors.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_motors.py @@ -58,6 +58,8 @@ def __init__(self, table_name, initial_data_directory): table_name=table_name, record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, + create_table_query=CREATE_HVAC_REQUIREMENT_MOTORS_TABLE % table_name, + insert_record_query=INSERT_A_MOTOR_RECORD % table_name ) def get_record_info(self): @@ -111,8 +113,4 @@ def _preprocess_record(self, record): getattr_either("annotation", record), ) - def _get_create_table_query(self): - return CREATE_HVAC_REQUIREMENT_MOTORS_TABLE % self.data_table_name - def _get_insert_record_query(self): - return INSERT_A_MOTOR_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_unitary_air_conditioners.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_unitary_air_conditioners.py index 54afde0efe..7563736b3f 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_unitary_air_conditioners.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_unitary_air_conditioners.py @@ -110,6 +110,8 @@ def __init__(self, table_name, initial_data_directory): table_name=table_name, record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, + create_table_query=CREATE_HVAC_REQUIREMENT_UNITARY_AIR_CONDITIONERS_TABLE % table_name, + insert_record_query=INSERT_A_UNITARY_AIR_CONDITIONERS_RECORD % table_name ) def get_record_info(self): @@ -186,12 +188,3 @@ def _preprocess_record(self, record): getattr_either("cool_plf_fplr", record), getattr_either("annotation", record), ) - - def _get_create_table_query(self): - return ( - CREATE_HVAC_REQUIREMENT_UNITARY_AIR_CONDITIONERS_TABLE - % self.data_table_name - ) - - def _get_insert_record_query(self): - return INSERT_A_UNITARY_AIR_CONDITIONERS_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_heaters.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_heaters.py index e413e0f5ed..962195f4d7 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_heaters.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_heaters.py @@ -86,6 +86,8 @@ def __init__(self, table_name, initial_data_directory): table_name=table_name, record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, + create_table_query=CREATE_HVAC_REQUIREMENT_WATER_HEATERS_TABLE % table_name, + insert_record_query=INSERT_A_WATER_HEATER_RECORD % table_name ) def get_record_info(self): @@ -152,9 +154,3 @@ def _preprocess_record(self, record): getattr_either("thermal_efficiency", record), getattr_either("annotation", record), ) - - def _get_create_table_query(self): - return CREATE_HVAC_REQUIREMENT_WATER_HEATERS_TABLE % self.data_table_name - - def _get_insert_record_query(self): - return INSERT_A_WATER_HEATER_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_cooling.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_cooling.py index 643cb56914..a3e201282c 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_cooling.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_cooling.py @@ -54,6 +54,8 @@ def __init__(self, table_name, initial_data_directory): table_name=table_name, record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, + create_table_query=CREATE_HVAC_REQUIREMENT_WATER_SOURCE_HEAT_PUMPS_COOLING_TABLE % table_name, + insert_record_query=INSERT_A_WATER_SOURCE_HEAT_PUMP_RECORD % table_name ) def get_record_info(self): @@ -117,12 +119,3 @@ def _preprocess_record(self, record): getattr_either("minimum_full_load_efficiency", record), getattr_either("annotation", record), ) - - def _get_create_table_query(self): - return ( - CREATE_HVAC_REQUIREMENT_WATER_SOURCE_HEAT_PUMPS_COOLING_TABLE - % self.data_table_name - ) - - def _get_insert_record_query(self): - return INSERT_A_WATER_SOURCE_HEAT_PUMP_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_heating.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_heating.py index e5a5fd097e..0f87c6ebbd 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_heating.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_heating.py @@ -54,6 +54,8 @@ def __init__(self, table_name, initial_data_directory): table_name=table_name, record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, + create_table_query=CREATE_HVAC_REQUIREMENT_WATER_SOURCE_HEAT_PUMPS_HEATING_TABLE % table_name, + insert_record_query=INSERT_A_WATER_SOURCE_HEAT_PUMP_RECORD % table_name ) def get_record_info(self): @@ -105,11 +107,3 @@ def _preprocess_record(self, record): getattr_either("annotation", record), ) - def _get_create_table_query(self): - return ( - CREATE_HVAC_REQUIREMENT_WATER_SOURCE_HEAT_PUMPS_HEATING_TABLE - % self.data_table_name - ) - - def _get_insert_record_query(self): - return INSERT_A_WATER_SOURCE_HEAT_PUMP_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/level_1_space_types.py b/data/openstudio_standards_data/database_tables/level_1_space_types.py index cd801e415f..8e2985551d 100644 --- a/data/openstudio_standards_data/database_tables/level_1_space_types.py +++ b/data/openstudio_standards_data/database_tables/level_1_space_types.py @@ -11,8 +11,8 @@ electric_equipment_space_type_name: TEXT """ -CREATE_level_1_space_types = f""" -CREATE TABLE IF NOT EXISTS {TABLE_NAME} +CREATE_LEVEL_1_SPACE_TYPES = f""" +CREATE TABLE IF NOT EXISTS %s (id INTEGER PRIMARY KEY, space_type_name TEXT NOT NULL, lighting_space_type_name TEXT, @@ -24,8 +24,8 @@ ); """ -INSERT_level_1_space_types = f""" - INSERT INTO {TABLE_NAME} +INSERT_LEVEL_1_SPACE_TYPES = f""" + INSERT INTO %s (space_type_name, lighting_space_type_name, ventilation_space_type_name, electric_equipment_space_type_name) VALUES (?, ?, ?, ?); """ @@ -45,6 +45,8 @@ def __init__(self): table_name=TABLE_NAME, record_template=RECORD_TEMPLATE, initial_data_directory=f"database_files/{TABLE_NAME}", + create_table_query=CREATE_LEVEL_1_SPACE_TYPES % TABLE_NAME, + insert_record_query=INSERT_LEVEL_1_SPACE_TYPES % TABLE_NAME ) def get_record_info(self): @@ -68,9 +70,3 @@ def _preprocess_record(self, record): getattr_either("ventilation_space_type_name", record), getattr_either("electric_equipment_space_type_name", record), ) - - def _get_create_table_query(self): - return CREATE_level_1_space_types - - def _get_insert_record_query(self): - return INSERT_level_1_space_types diff --git a/data/openstudio_standards_data/database_tables/level_2_electric_equipment.py b/data/openstudio_standards_data/database_tables/level_2_electric_equipment.py index 80e382702b..7be85a057d 100644 --- a/data/openstudio_standards_data/database_tables/level_2_electric_equipment.py +++ b/data/openstudio_standards_data/database_tables/level_2_electric_equipment.py @@ -16,7 +16,7 @@ electric_equipment_epd_unit: TEXT """ -CREATE_level_2_electric_equipment = """ +CREATE_LEVEL_2_ELECTRIC_EQUIPMENT = """ CREATE TABLE IF NOT EXISTS %s (id INTEGER PRIMARY KEY, electric_equipment_space_type_name TEXT NOT NULL, @@ -49,6 +49,8 @@ def __init__(self): table_name=TABLE_NAME, record_template=RECORD_TEMPLATE, initial_data_directory=f"database_files/{TABLE_NAME}", + create_table_query=CREATE_LEVEL_2_ELECTRIC_EQUIPMENT % TABLE_NAME, + insert_record_query=INSERT_EQUIP_LOAD_RECORD % TABLE_NAME ) def get_record_info(self): @@ -87,9 +89,3 @@ def _preprocess_record(self, record): getattr_either("electric_equipment_epd_unit", record, ""), ) return record_tuple - - def _get_create_table_query(self): - return CREATE_level_2_electric_equipment % self.data_table_name - - def _get_insert_record_query(self): - return INSERT_EQUIP_LOAD_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py b/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py index 5c8a0d4dc9..b860d49ec6 100644 --- a/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py +++ b/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py @@ -10,8 +10,8 @@ level_3_lighting_definition_id: id from level_3_lighting_definition index """ -LIGHT_SUBSPACE_TABLE = """ -CREATE TABLE IF NOT EXISTS level_2_lighting_space_types +CREATE_LIGHT_SUBSPACE_TABLE = """ +CREATE TABLE IF NOT EXISTS %s (id INTEGER PRIMARY KEY, lighting_space_type_name TEXT NOT NULL, level_3_lighting_definition_table TEXT NOT NULL, @@ -21,7 +21,7 @@ """ INSERT_LIGHT_SUBSPACE = f""" - INSERT INTO {TABLE_NAME} + INSERT INTO %s (lighting_space_type_name, level_3_lighting_definition_table, level_3_lighting_definition_id) VALUES (?, ?, ?); """ @@ -39,6 +39,8 @@ def __init__(self): table_name=TABLE_NAME, record_template=RECORD_TEMPLATE, initial_data_directory=f"database_files/{TABLE_NAME}", + create_table_query=CREATE_LIGHT_SUBSPACE_TABLE % TABLE_NAME, + insert_record_query=INSERT_LIGHT_SUBSPACE % TABLE_NAME ) def get_record_info(self): @@ -68,8 +70,3 @@ def _preprocess_record(self, record): return record_list - def _get_create_table_query(self): - return LIGHT_SUBSPACE_TABLE - - def _get_insert_record_query(self): - return INSERT_LIGHT_SUBSPACE diff --git a/data/openstudio_standards_data/database_tables/level_2_ventilation_space_types.py b/data/openstudio_standards_data/database_tables/level_2_ventilation_space_types.py index e47001f5ab..05fa9e7f7e 100644 --- a/data/openstudio_standards_data/database_tables/level_2_ventilation_space_types.py +++ b/data/openstudio_standards_data/database_tables/level_2_ventilation_space_types.py @@ -10,8 +10,8 @@ level_3_ventilation_definition_id: id from level_3_ventilation_definition index """ -VENT_SUBSPACE_TABLE = """ -CREATE TABLE IF NOT EXISTS level_2_ventilation_space_types +CREATE_VENT_SUBSPACE_TABLE = """ +CREATE TABLE IF NOT EXISTS %s (id INTEGER PRIMARY KEY, ventilation_space_type_name TEXT NOT NULL, level_3_ventilation_definition_table TEXT NOT NULL, @@ -22,7 +22,7 @@ """ INSERT_VENT_SUBSPACE = f""" - INSERT INTO {TABLE_NAME} + INSERT INTO %s (ventilation_space_type_name, level_3_ventilation_definition_table, level_3_ventilation_definition_id) VALUES (?, ?, ?); """ @@ -40,6 +40,8 @@ def __init__(self): table_name=TABLE_NAME, record_template=RECORD_TEMPLATE, initial_data_directory=f"database_files/{TABLE_NAME}", + create_table_query=CREATE_VENT_SUBSPACE_TABLE % TABLE_NAME, + insert_record_query=INSERT_VENT_SUBSPACE % TABLE_NAME ) def get_record_info(self): @@ -70,8 +72,3 @@ def _preprocess_record(self, record): return record_list - def _get_create_table_query(self): - return VENT_SUBSPACE_TABLE - - def _get_insert_record_query(self): - return INSERT_VENT_SUBSPACE diff --git a/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_definition.py b/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_definition.py index 39260c77d3..e840f388d7 100644 --- a/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_definition.py +++ b/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_definition.py @@ -46,6 +46,8 @@ def __init__(self, table_name, initial_data_directory): table_name=table_name, record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, + create_table_query=CREATE_LIGHT_DEF_90_1_TABLE % table_name, + insert_record_query=INSERT_A_LIGHT_RECORD % table_name ) def get_record_info(self): @@ -83,8 +85,3 @@ def _preprocess_record(self, record): ) return record_tuple - def _get_create_table_query(self): - return CREATE_LIGHT_DEF_90_1_TABLE % self.data_table_name - - def _get_insert_record_query(self): - return INSERT_A_LIGHT_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_definition.py b/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_definition.py index 633f943aad..2033392ac4 100644 --- a/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_definition.py +++ b/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_definition.py @@ -62,6 +62,8 @@ def __init__(self, table_name, initial_data_directory): table_name=table_name, record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, + create_table_query=CREATE_VENT_DEF_62_1_TABLE % table_name, + insert_record_query=INSERT_A_VENT_RECORD % table_name ) def get_record_info(self): @@ -105,8 +107,3 @@ def _preprocess_record(self, record): getattr_either("annotation", record, ""), ) - def _get_create_table_query(self): - return CREATE_VENT_DEF_62_1_TABLE % self.data_table_name - - def _get_insert_record_query(self): - return INSERT_A_VENT_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/support_constructions.py b/data/openstudio_standards_data/database_tables/support_constructions.py index d82e3130c6..1a826ab240 100644 --- a/data/openstudio_standards_data/database_tables/support_constructions.py +++ b/data/openstudio_standards_data/database_tables/support_constructions.py @@ -19,7 +19,7 @@ """ CREATE_CONSTRUCTIONS_TABLE = f""" -CREATE TABLE IF NOT EXISTS {TABLE_NAME} +CREATE TABLE IF NOT EXISTS %s (name TEXT UNIQUE NOT NULL PRIMARY KEY, intended_surface_type TEXT, standards_construction_type TEXT, @@ -41,7 +41,7 @@ """ INSERT_CONSTRUCTION = f""" - INSERT INTO {TABLE_NAME} + INSERT INTO %s (name, intended_surface_type, standards_construction_type, @@ -78,6 +78,8 @@ def __init__(self): table_name=TABLE_NAME, record_template=RECORD_TEMPLATE, initial_data_directory=f"database_files/{TABLE_NAME}", + create_table_query=CREATE_CONSTRUCTIONS_TABLE % TABLE_NAME, + insert_record_query=INSERT_CONSTRUCTION % TABLE_NAME ) def get_record_info(self): @@ -129,8 +131,3 @@ def _preprocess_record(self, record): getattr_either("material_6", record), ) - def _get_create_table_query(self): - return CREATE_CONSTRUCTIONS_TABLE - - def _get_insert_record_query(self): - return INSERT_CONSTRUCTION diff --git a/data/openstudio_standards_data/database_tables/support_electric_equipment_space_type_name_tags.py b/data/openstudio_standards_data/database_tables/support_electric_equipment_space_type_name_tags.py index e3a3d3cf9a..c6bc568829 100644 --- a/data/openstudio_standards_data/database_tables/support_electric_equipment_space_type_name_tags.py +++ b/data/openstudio_standards_data/database_tables/support_electric_equipment_space_type_name_tags.py @@ -8,15 +8,15 @@ support_electric_equipment_space_type_name_tags: TEXT """ -CREATE_support_electric_equipment_space_type_name_tags = f""" -CREATE TABLE IF NOT EXISTS {TABLE_NAME} +CREATE_SUPPORT_ELECTRIC_EQUIPMENT_SPACE_TYPE_NAME_TAGS = f""" +CREATE TABLE IF NOT EXISTS %s ( support_electric_equipment_space_type_name_tags TEXT UNIQUE NOT NULL PRIMARY KEY ); """ INSERT_SPACE_TAG = f""" - INSERT INTO {TABLE_NAME} + INSERT INTO %s (support_electric_equipment_space_type_name_tags) VALUES (?); """ @@ -33,6 +33,8 @@ def __init__(self): table_name=TABLE_NAME, record_template=RECORD_TEMPLATE, initial_data_directory=f"database_files/{TABLE_NAME}", + create_table_query=CREATE_SUPPORT_ELECTRIC_EQUIPMENT_SPACE_TYPE_NAME_TAGS % TABLE_NAME, + insert_record_query=INSERT_SPACE_TAG % TABLE_NAME ) def get_record_info(self): @@ -51,9 +53,3 @@ def _preprocess_record(self, record): return ( getattr_either("support_electric_equipment_space_type_name_tags", record), ) - - def _get_create_table_query(self): - return CREATE_support_electric_equipment_space_type_name_tags - - def _get_insert_record_query(self): - return INSERT_SPACE_TAG diff --git a/data/openstudio_standards_data/database_tables/support_lighting_space_type_name_tags.py b/data/openstudio_standards_data/database_tables/support_lighting_space_type_name_tags.py index 2ff6a57036..eb5bdd7383 100644 --- a/data/openstudio_standards_data/database_tables/support_lighting_space_type_name_tags.py +++ b/data/openstudio_standards_data/database_tables/support_lighting_space_type_name_tags.py @@ -9,14 +9,14 @@ """ CREATE_LIGHTING_SPACE_TAG = f""" -CREATE TABLE IF NOT EXISTS {TABLE_NAME} +CREATE TABLE IF NOT EXISTS %s ( lighting_space_type_name TEXT UNIQUE NOT NULL PRIMARY KEY ); """ INSERT_SPACE_TAG = f""" - INSERT INTO {TABLE_NAME} + INSERT INTO %s (lighting_space_type_name) VALUES (?); """ @@ -33,6 +33,8 @@ def __init__(self): table_name=TABLE_NAME, record_template=RECORD_TEMPLATE, initial_data_directory=f"database_files/{TABLE_NAME}", + create_table_query=CREATE_LIGHTING_SPACE_TAG % TABLE_NAME, + insert_record_query=INSERT_SPACE_TAG % TABLE_NAME ) def get_record_info(self): @@ -50,8 +52,3 @@ def _preprocess_record(self, record): """ return (getattr_either("lighting_space_type_name", record),) - def _get_create_table_query(self): - return CREATE_LIGHTING_SPACE_TAG - - def _get_insert_record_query(self): - return INSERT_SPACE_TAG diff --git a/data/openstudio_standards_data/database_tables/support_materials.py b/data/openstudio_standards_data/database_tables/support_materials.py index ae0bceba5d..5290963945 100644 --- a/data/openstudio_standards_data/database_tables/support_materials.py +++ b/data/openstudio_standards_data/database_tables/support_materials.py @@ -37,7 +37,7 @@ """ CREATE_MATERIALS_TABLE = f""" -CREATE TABLE IF NOT EXISTS {TABLE_NAME} +CREATE TABLE IF NOT EXISTS %s (name TEXT UNIQUE NOT NULL PRIMARY KEY, material_type TEXT, roughness NUMERIC, @@ -71,7 +71,7 @@ """ INSERT_MATERIAL = f""" - INSERT INTO {TABLE_NAME} + INSERT INTO %s (name, material_type, roughness, @@ -144,6 +144,8 @@ def __init__(self): table_name=TABLE_NAME, record_template=RECORD_TEMPLATE, initial_data_directory=f"database_files/{TABLE_NAME}", + create_table_query=CREATE_MATERIALS_TABLE % TABLE_NAME, + insert_record_query=INSERT_MATERIAL % TABLE_NAME ) def get_record_info(self): @@ -243,9 +245,3 @@ def _preprocess_record(self, record): getattr_either("frame_width", record), getattr_either("annotation", record), ) - - def _get_create_table_query(self): - return CREATE_MATERIALS_TABLE - - def _get_insert_record_query(self): - return INSERT_MATERIAL diff --git a/data/openstudio_standards_data/database_tables/support_performance_curves.py b/data/openstudio_standards_data/database_tables/support_performance_curves.py index d9fcfceaa3..6863ee60d8 100644 --- a/data/openstudio_standards_data/database_tables/support_performance_curves.py +++ b/data/openstudio_standards_data/database_tables/support_performance_curves.py @@ -32,7 +32,7 @@ """ CREATE_PERFORMANCE_CURVES_TABLE = f""" -CREATE TABLE IF NOT EXISTS {TABLE_NAME} +CREATE TABLE IF NOT EXISTS %s ( id INTEGER PRIMARY KEY, name TEXT NOT NULL, @@ -62,7 +62,7 @@ """ INSERT_PERFORMANCE_CURVE = f""" - INSERT INTO {TABLE_NAME} + INSERT INTO %s ( name, category, @@ -124,6 +124,8 @@ def __init__(self): table_name=TABLE_NAME, record_template=RECORD_TEMPLATE, initial_data_directory=f"database_files/{TABLE_NAME}", + create_table_query=CREATE_PERFORMANCE_CURVES_TABLE % TABLE_NAME, + insert_record_query=INSERT_PERFORMANCE_CURVE % TABLE_NAME ) def get_record_info(self): @@ -205,8 +207,3 @@ def _preprocess_record(self, record): getattr_either("annotation", record), ) - def _get_create_table_query(self): - return CREATE_PERFORMANCE_CURVES_TABLE - - def _get_insert_record_query(self): - return INSERT_PERFORMANCE_CURVE diff --git a/data/openstudio_standards_data/database_tables/support_standard_templates.py b/data/openstudio_standards_data/database_tables/support_standard_templates.py index 5852016c5a..6f35554820 100644 --- a/data/openstudio_standards_data/database_tables/support_standard_templates.py +++ b/data/openstudio_standards_data/database_tables/support_standard_templates.py @@ -12,8 +12,8 @@ ventilation_standard, TEXT """ -CREATE_support_standard_templates = """ -CREATE TABLE IF NOT EXISTS support_standard_templates +CREATE_SUPPORT_STANDARD_TEMPLATES = """ +CREATE TABLE IF NOT EXISTS %s (id INTEGER PRIMARY KEY, template TEXT NOT NULL UNIQUE, lighting_standard TEXT, @@ -23,7 +23,7 @@ """ INSERT_A_TEMPLATE_RECORD = """ - INSERT INTO support_standard_templates (template, + INSERT INTO %s (template, lighting_standard, lighting_standard_table, ventilation_standard, ventilation_standard_table) VALUES (?, ?, ?, ? , ?); """ @@ -43,6 +43,8 @@ def __init__(self): table_name=TABLE_NAME, record_template=RECORD_TEMPLATE, initial_data_directory=f"database_files/{TABLE_NAME}", + create_table_query=CREATE_SUPPORT_STANDARD_TEMPLATES % TABLE_NAME, + insert_record_query=INSERT_A_TEMPLATE_RECORD % TABLE_NAME ) def get_record_info(self): @@ -67,8 +69,3 @@ def _preprocess_record(self, record): getattr_either("ventilation_standard_table", record), ) - def _get_create_table_query(self): - return CREATE_support_standard_templates - - def _get_insert_record_query(self): - return INSERT_A_TEMPLATE_RECORD diff --git a/data/openstudio_standards_data/database_tables/support_ventilation_space_type_name_tags.py b/data/openstudio_standards_data/database_tables/support_ventilation_space_type_name_tags.py index 0f03ed99d6..b705ff58a8 100644 --- a/data/openstudio_standards_data/database_tables/support_ventilation_space_type_name_tags.py +++ b/data/openstudio_standards_data/database_tables/support_ventilation_space_type_name_tags.py @@ -8,15 +8,15 @@ ventilation_space_type_name: TEXT """ -CREATE_ventilation_space_type_name = f""" -CREATE TABLE IF NOT EXISTS {TABLE_NAME} +CREATE_VENTILATION_SPACE_TYPE_NAME = f""" +CREATE TABLE IF NOT EXISTS %s ( ventilation_space_type_name TEXT UNIQUE NOT NULL PRIMARY KEY ); """ INSERT_SPACE_TAG = f""" - INSERT INTO {TABLE_NAME} + INSERT INTO %s (ventilation_space_type_name) VALUES (?); """ @@ -33,6 +33,8 @@ def __init__(self): table_name=TABLE_NAME, record_template=RECORD_TEMPLATE, initial_data_directory=f"database_files/{TABLE_NAME}", + create_table_query=CREATE_VENTILATION_SPACE_TYPE_NAME % TABLE_NAME, + insert_record_query=INSERT_SPACE_TAG % TABLE_NAME ) def get_record_info(self): @@ -51,8 +53,3 @@ def _preprocess_record(self, record): return (getattr_either("ventilation_space_type_name", record),) - def _get_create_table_query(self): - return CREATE_ventilation_space_type_name - - def _get_insert_record_query(self): - return INSERT_SPACE_TAG diff --git a/data/openstudio_standards_data/database_tables/system_requirement_economizer.py b/data/openstudio_standards_data/database_tables/system_requirement_economizer.py index d94751a7a0..784dea57d1 100644 --- a/data/openstudio_standards_data/database_tables/system_requirement_economizer.py +++ b/data/openstudio_standards_data/database_tables/system_requirement_economizer.py @@ -50,6 +50,8 @@ def __init__(self, table_name, initial_data_directory): table_name=table_name, record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, + create_table_query=CREATE_SYSTEM_REQUIREMENT_ECONOMIZER_TABLE % table_name, + insert_record_query=INSERT_A_SYSTEM_REQUIREMENT_ECONOMIZER % table_name ) def get_record_info(self): @@ -101,9 +103,3 @@ def _preprocess_record(self, record): getattr_either("fixed_dry_bulb_high_limit_shutoff_temp", record), getattr_either("annotation", record), ) - - def _get_create_table_query(self): - return CREATE_SYSTEM_REQUIREMENT_ECONOMIZER_TABLE % self.data_table_name - - def _get_insert_record_query(self): - return INSERT_A_SYSTEM_REQUIREMENT_ECONOMIZER % self.data_table_name diff --git a/data/openstudio_standards_data/database_tables/system_requirement_energy_recovery.py b/data/openstudio_standards_data/database_tables/system_requirement_energy_recovery.py index b882c83d34..9f5fb48b2b 100644 --- a/data/openstudio_standards_data/database_tables/system_requirement_energy_recovery.py +++ b/data/openstudio_standards_data/database_tables/system_requirement_energy_recovery.py @@ -90,6 +90,8 @@ def __init__(self, table_name, initial_data_directory): table_name=table_name, record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, + create_table_query=CREATE_SYSTEM_REQUIREMENT_ENERGY_RECOVERY_TABLE % table_name, + insert_record_query=INSERT_A_SYSTEM_REQUIREMENT_ENERGY_RECOVERY_RECORD % table_name ) def get_record_info(self): @@ -159,8 +161,3 @@ def _preprocess_record(self, record): getattr_either("annotation", record), ) - def _get_create_table_query(self): - return CREATE_SYSTEM_REQUIREMENT_ENERGY_RECOVERY_TABLE % self.data_table_name - - def _get_insert_record_query(self): - return INSERT_A_SYSTEM_REQUIREMENT_ENERGY_RECOVERY_RECORD % self.data_table_name diff --git a/data/openstudio_standards_data/test/test_database.py b/data/openstudio_standards_data/test/test_database.py index 3396e901bf..21839e3f22 100644 --- a/data/openstudio_standards_data/test/test_database.py +++ b/data/openstudio_standards_data/test/test_database.py @@ -1,3 +1,4 @@ +import unittest from unittest import TestCase from unittest import mock import os @@ -11,26 +12,96 @@ export_openstudio_standards_database_to_csv, export_openstudio_standards_database_to_json, ) - - -class TestDatabaseQueries(TestCase): - """ - Test database - unfinished - """ - - def fix_dbc(self): - dbc = mock.MagicMock(spec=["cursor"]) - dbc.autocommit = True - return dbc - - def fix_rows(self): - rows = [{"id": 1, "name": "John"}, {"id": 2, "name": "Jane"}] - return rows - - def test_insert_rows_calls_cursor_method(self): - dbc = self.fix_dbc() - rows = self.fix_rows() - pass +from database_engine.database import DBOperation + + +CREATE_L3_TEST_TABLE = """ +CREATE TABLE level_3_table (id INTEGER PRIMARY KEY, name TEXT); +""" +INSERT_L3_TEST_TABLE = f""" + INSERT INTO level_3_table + (name) + VALUES (?); +""" + +CREATE_L2_TABLE = """ +CREATE TABLE level_2_table (id INTEGER PRIMARY KEY, associate_table TEXT, foreign_key TEXT) +""" + +INSERT_L2_TABLE = f""" + INSERT INTO level_2_table + (associate_table, foreign_key) + VALUES (?, ?); +""" + + +class SampleL3TestTable(DBOperation): + def __init__(self): + super(SampleL3TestTable, self).__init__( + table_name="l3_table", + record_template={}, + initial_data_directory="", + create_table_query=CREATE_L3_TEST_TABLE, + insert_record_query=INSERT_L3_TEST_TABLE + ) + + def _preprocess_record(self, record): + return ( + record["name"], + ) + + +class SampleL2TestTable(DBOperation): + def __init__(self): + super(SampleL2TestTable, self).__init__( + table_name="test_table", + record_template={}, + initial_data_directory="", + create_table_query=CREATE_L2_TABLE, + insert_record_query=INSERT_L2_TABLE + ) + + def _preprocess_record(self, record): + return ( + record["associate_table"], + record["foreign_key"] + ) + + def _get_weak_foreign_key_value(self, record): + return record["associate_table"], "id", record["foreign_key"] + + +class TestWeakForeignKeyAssociation(unittest.TestCase): + def setUp(self): + # Create a test database with two tables and index + self.conn = sqlite3.connect(":memory:") + self.cur = self.conn.cursor() + self.level_2_table = SampleL2TestTable() + self.level_3_table = SampleL3TestTable() + self.level_2_table.create_a_table(self.conn) + self.level_3_table.create_a_table(self.conn) + self.level_3_table.add_a_record(self.conn, {"name":"test_value_1"}) # index 1 + self.level_3_table.add_a_record(self.conn, {"name":"test_value_2"}) # index 2 + + def tearDown(self): + # close the database connection + self.cur.close() + self.conn.close() + + def test_index_exists(self): + # Test that the function correctly identifies an existing index + add_success = self.level_2_table.add_a_record(self.conn, {"associate_table": "level_3_table", "foreign_key": "1"}) + self.assertTrue(add_success) + + def test_index_does_not_exist(self): + # Test that the function validated the index is not exist + add_success = self.level_2_table.add_a_record(self.conn, {"associate_table": "level_3_table", "foreign_key": "3"}) + self.assertFalse(add_success) + + def test_table_does_not_exist(self): + # Test if the table is not exist + add_success = self.level_2_table.add_a_record(self.conn, {"associate_table": "missing_table", "foreign_key": "1"}) + self.assertFalse(add_success) def create_db(db_name, from_type=""): From a0d711851a554d79f26cd9dcc16d65fa259816c8 Mon Sep 17 00:00:00 2001 From: Weili Xu Date: Tue, 28 Mar 2023 11:04:24 -0700 Subject: [PATCH 12/45] update format --- .../database_engine/database.py | 18 +++++++++--- .../database_tables/envelope_requirement.py | 16 +++++----- .../hvac_minimum_requirement_boilers.py | 2 +- .../hvac_minimum_requirement_chillers.py | 3 +- .../hvac_minimum_requirement_furnaces.py | 2 +- ...c_minimum_requirement_heat_pump_cooling.py | 6 ++-- ...c_minimum_requirement_heat_pump_heating.py | 5 ++-- ...hvac_minimum_requirement_heat_rejection.py | 6 ++-- .../hvac_minimum_requirement_motors.py | 4 +-- ...um_requirement_unitary_air_conditioners.py | 5 ++-- .../hvac_minimum_requirement_water_heaters.py | 2 +- ...irement_water_source_heat_pumps_cooling.py | 5 ++-- ...irement_water_source_heat_pumps_heating.py | 6 ++-- .../database_tables/level_1_space_types.py | 2 +- .../level_2_electric_equipment.py | 2 +- .../level_2_lighting_space_types.py | 7 ++--- .../level_2_ventilation_space_types.py | 9 +++--- .../level_3_lighting_90_1_definition.py | 3 +- .../level_3_ventilation_62_1_definition.py | 3 +- .../database_tables/support_constructions.py | 3 +- ...electric_equipment_space_type_name_tags.py | 5 ++-- .../support_lighting_space_type_name_tags.py | 3 +- .../database_tables/support_materials.py | 2 +- .../support_performance_curves.py | 3 +- .../support_standard_templates.py | 3 +- ...upport_ventilation_space_type_name_tags.py | 3 +- .../system_requirement_economizer.py | 2 +- .../system_requirement_energy_recovery.py | 7 +++-- data/openstudio_standards_data/query/util.py | 4 ++- .../test/test_database.py | 29 ++++++++++--------- 30 files changed, 90 insertions(+), 80 deletions(-) diff --git a/data/openstudio_standards_data/database_engine/database.py b/data/openstudio_standards_data/database_engine/database.py index aa48f0adaf..79ab4d5a3c 100644 --- a/data/openstudio_standards_data/database_engine/database.py +++ b/data/openstudio_standards_data/database_engine/database.py @@ -26,7 +26,14 @@ def create_connect(db_file): class DBOperation: - def __init__(self, table_name, record_template, initial_data_directory, create_table_query, insert_record_query): + def __init__( + self, + table_name, + record_template, + initial_data_directory, + create_table_query, + insert_record_query, + ): """ DB Operation class :param table_name: String name of the table @@ -61,7 +68,9 @@ def add_a_record(self, connection, record: dict): # run data validation, raise exception if data is not validated. cur = connection.cursor() success_added = False - if self.validate_record_datatype(record) and self.validate_weak_foreign_key(connection, record): + if self.validate_record_datatype(record) and self.validate_weak_foreign_key( + connection, record + ): cur.execute(self.insert_record_query, self._preprocess_record(record)) connection.commit() success_added = True @@ -113,7 +122,9 @@ def validate_weak_foreign_key(self, conn, record): """ associate_table, key, value = self._get_weak_foreign_key_value(record) # any value is Falsy (no association) should return True, or pass the is_index_in_table check. - return not all([associate_table, key, value]) or is_index_in_table(conn, associate_table, key, value) + return not all([associate_table, key, value]) or is_index_in_table( + conn, associate_table, key, value + ) def export_table_to_csv(self, conn, save_dir=""): """ @@ -186,4 +197,3 @@ def _get_retrieve_all_query(self): :return: """ return f"SELECT * FROM {self.data_table_name}" - diff --git a/data/openstudio_standards_data/database_tables/envelope_requirement.py b/data/openstudio_standards_data/database_tables/envelope_requirement.py index 48efd6c23d..e46a1556df 100644 --- a/data/openstudio_standards_data/database_tables/envelope_requirement.py +++ b/data/openstudio_standards_data/database_tables/envelope_requirement.py @@ -100,7 +100,7 @@ def __init__(self): record_template=RECORD_TEMPLATE, initial_data_directory=f"database_files/{TABLE_NAME}", create_table_query=CREATE_ENVELOPE_REQUIREMENTS_TABLE % TABLE_NAME, - insert_record_query=INSERT_A_ENVELOPE_REQUIREMENT_RECORD % TABLE_NAME + insert_record_query=INSERT_A_ENVELOPE_REQUIREMENT_RECORD % TABLE_NAME, ) def get_record_info(self): @@ -125,9 +125,10 @@ def validate_record_datatype(self, record): for f in str_expected: if record.get(f): - assert_(isinstance( - record[f], str - ), f"{f} requires to be a string, instead got {record[f]}") + assert_( + isinstance(record[f], str), + f"{f} requires to be a string, instead got {record[f]}", + ) float_expected = [ "minimum_percent_of_surface", @@ -141,9 +142,10 @@ def validate_record_datatype(self, record): for f in float_expected: if record.get(f): - assert_(is_float( - record.get(f) - ), f"{f} requires to be numeric data type, instead got {record[f]}") + assert_( + is_float(record.get(f)), + f"{f} requires to be numeric data type, instead got {record[f]}", + ) return True def _preprocess_record(self, record): diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_boilers.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_boilers.py index 96242adf8b..4c3d8da13f 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_boilers.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_boilers.py @@ -83,7 +83,7 @@ def __init__(self, table_name, initial_data_directory): record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, create_table_query=CREATE_HVAC_REQ_BOILER_TABLE % table_name, - insert_record_query=INSERT_A_BOILER_RECORD % table_name + insert_record_query=INSERT_A_BOILER_RECORD % table_name, ) def get_record_info(self): diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_chillers.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_chillers.py index e9d874f41b..b1e51d92c1 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_chillers.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_chillers.py @@ -91,7 +91,7 @@ def __init__(self, table_name, initial_data_directory): record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, create_table_query=CREATE_HVAC_REQUIREMENT_CHILLERS_TABLE % table_name, - insert_record_query=INSERT_A_CHILLER_RECORD % table_name + insert_record_query=INSERT_A_CHILLER_RECORD % table_name, ) def get_record_info(self): @@ -160,4 +160,3 @@ def _preprocess_record(self, record): getattr_either("eirfplr", record), getattr_either("annotation", record), ) - diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_furnaces.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_furnaces.py index d596c26ef4..823d86b060 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_furnaces.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_furnaces.py @@ -63,7 +63,7 @@ def __init__(self, table_name, initial_data_directory): record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, create_table_query=CREATE_HVAC_REQUIREMENT_FURNACES_TABLE % table_name, - insert_record_query=INSERT_A_FURNACE_RECORD % table_name + insert_record_query=INSERT_A_FURNACE_RECORD % table_name, ) def get_record_info(self): diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_cooling.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_cooling.py index 28ffae193a..e142337066 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_cooling.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_cooling.py @@ -106,8 +106,9 @@ def __init__(self, table_name, initial_data_directory): table_name=table_name, record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, - create_table_query=CREATE_HVAC_REQUIREMENT_HEAT_PUMP_COOLING_TABLE % table_name, - insert_record_query=INSERT_A_HEAT_PUMP_COOLING_RECORD % table_name + create_table_query=CREATE_HVAC_REQUIREMENT_HEAT_PUMP_COOLING_TABLE + % table_name, + insert_record_query=INSERT_A_HEAT_PUMP_COOLING_RECORD % table_name, ) def get_record_info(self): @@ -184,4 +185,3 @@ def _preprocess_record(self, record): getattr_either("cool_plf_fplr", record), getattr_either("annotation", record), ) - diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_heating.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_heating.py index 499de7fa6a..e95ab28dbf 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_heating.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_heating.py @@ -98,8 +98,9 @@ def __init__(self, table_name, initial_data_directory): table_name=table_name, record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, - create_table_query=CREATE_HVAC_REQUIREMENT_HEAT_PUMP_HEATING_TABLE % table_name, - insert_record_query=INSERT_A_HEAT_PUMP_HEATING_RECORD % table_name + create_table_query=CREATE_HVAC_REQUIREMENT_HEAT_PUMP_HEATING_TABLE + % table_name, + insert_record_query=INSERT_A_HEAT_PUMP_HEATING_RECORD % table_name, ) def get_record_info(self): diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_rejection.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_rejection.py index 293db683b0..f1c5d3cf97 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_rejection.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_rejection.py @@ -54,8 +54,9 @@ def __init__(self, table_name, initial_data_directory): table_name=table_name, record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, - create_table_query=CREATE_HVAC_REQUIREMENT_HEAT_REJECTION_TABLE % table_name, - insert_record_query=INSERT_A_HEAT_REJECTION_RECORD % table_name + create_table_query=CREATE_HVAC_REQUIREMENT_HEAT_REJECTION_TABLE + % table_name, + insert_record_query=INSERT_A_HEAT_REJECTION_RECORD % table_name, ) def get_record_info(self): @@ -101,4 +102,3 @@ def _preprocess_record(self, record): getattr_either("minimum_performance_gpm_per_hp", record), getattr_either("annotation", record), ) - diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_motors.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_motors.py index 04c1236ce0..80f789eb3f 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_motors.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_motors.py @@ -59,7 +59,7 @@ def __init__(self, table_name, initial_data_directory): record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, create_table_query=CREATE_HVAC_REQUIREMENT_MOTORS_TABLE % table_name, - insert_record_query=INSERT_A_MOTOR_RECORD % table_name + insert_record_query=INSERT_A_MOTOR_RECORD % table_name, ) def get_record_info(self): @@ -112,5 +112,3 @@ def _preprocess_record(self, record): getattr_either("nominal_full_load_efficiency", record), getattr_either("annotation", record), ) - - diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_unitary_air_conditioners.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_unitary_air_conditioners.py index 7563736b3f..e1b822b876 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_unitary_air_conditioners.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_unitary_air_conditioners.py @@ -110,8 +110,9 @@ def __init__(self, table_name, initial_data_directory): table_name=table_name, record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, - create_table_query=CREATE_HVAC_REQUIREMENT_UNITARY_AIR_CONDITIONERS_TABLE % table_name, - insert_record_query=INSERT_A_UNITARY_AIR_CONDITIONERS_RECORD % table_name + create_table_query=CREATE_HVAC_REQUIREMENT_UNITARY_AIR_CONDITIONERS_TABLE + % table_name, + insert_record_query=INSERT_A_UNITARY_AIR_CONDITIONERS_RECORD % table_name, ) def get_record_info(self): diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_heaters.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_heaters.py index 962195f4d7..67fca268c5 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_heaters.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_heaters.py @@ -87,7 +87,7 @@ def __init__(self, table_name, initial_data_directory): record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, create_table_query=CREATE_HVAC_REQUIREMENT_WATER_HEATERS_TABLE % table_name, - insert_record_query=INSERT_A_WATER_HEATER_RECORD % table_name + insert_record_query=INSERT_A_WATER_HEATER_RECORD % table_name, ) def get_record_info(self): diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_cooling.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_cooling.py index a3e201282c..7c52dc6fca 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_cooling.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_cooling.py @@ -54,8 +54,9 @@ def __init__(self, table_name, initial_data_directory): table_name=table_name, record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, - create_table_query=CREATE_HVAC_REQUIREMENT_WATER_SOURCE_HEAT_PUMPS_COOLING_TABLE % table_name, - insert_record_query=INSERT_A_WATER_SOURCE_HEAT_PUMP_RECORD % table_name + create_table_query=CREATE_HVAC_REQUIREMENT_WATER_SOURCE_HEAT_PUMPS_COOLING_TABLE + % table_name, + insert_record_query=INSERT_A_WATER_SOURCE_HEAT_PUMP_RECORD % table_name, ) def get_record_info(self): diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_heating.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_heating.py index 0f87c6ebbd..78f1e515f1 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_heating.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_heating.py @@ -54,8 +54,9 @@ def __init__(self, table_name, initial_data_directory): table_name=table_name, record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, - create_table_query=CREATE_HVAC_REQUIREMENT_WATER_SOURCE_HEAT_PUMPS_HEATING_TABLE % table_name, - insert_record_query=INSERT_A_WATER_SOURCE_HEAT_PUMP_RECORD % table_name + create_table_query=CREATE_HVAC_REQUIREMENT_WATER_SOURCE_HEAT_PUMPS_HEATING_TABLE + % table_name, + insert_record_query=INSERT_A_WATER_SOURCE_HEAT_PUMP_RECORD % table_name, ) def get_record_info(self): @@ -106,4 +107,3 @@ def _preprocess_record(self, record): getattr_either("minimum_coefficient_of_performance", record), getattr_either("annotation", record), ) - diff --git a/data/openstudio_standards_data/database_tables/level_1_space_types.py b/data/openstudio_standards_data/database_tables/level_1_space_types.py index 8e2985551d..d0b42b6200 100644 --- a/data/openstudio_standards_data/database_tables/level_1_space_types.py +++ b/data/openstudio_standards_data/database_tables/level_1_space_types.py @@ -46,7 +46,7 @@ def __init__(self): record_template=RECORD_TEMPLATE, initial_data_directory=f"database_files/{TABLE_NAME}", create_table_query=CREATE_LEVEL_1_SPACE_TYPES % TABLE_NAME, - insert_record_query=INSERT_LEVEL_1_SPACE_TYPES % TABLE_NAME + insert_record_query=INSERT_LEVEL_1_SPACE_TYPES % TABLE_NAME, ) def get_record_info(self): diff --git a/data/openstudio_standards_data/database_tables/level_2_electric_equipment.py b/data/openstudio_standards_data/database_tables/level_2_electric_equipment.py index 7be85a057d..3faa52b8ae 100644 --- a/data/openstudio_standards_data/database_tables/level_2_electric_equipment.py +++ b/data/openstudio_standards_data/database_tables/level_2_electric_equipment.py @@ -50,7 +50,7 @@ def __init__(self): record_template=RECORD_TEMPLATE, initial_data_directory=f"database_files/{TABLE_NAME}", create_table_query=CREATE_LEVEL_2_ELECTRIC_EQUIPMENT % TABLE_NAME, - insert_record_query=INSERT_EQUIP_LOAD_RECORD % TABLE_NAME + insert_record_query=INSERT_EQUIP_LOAD_RECORD % TABLE_NAME, ) def get_record_info(self): diff --git a/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py b/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py index b860d49ec6..53a5346833 100644 --- a/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py +++ b/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py @@ -40,7 +40,7 @@ def __init__(self): record_template=RECORD_TEMPLATE, initial_data_directory=f"database_files/{TABLE_NAME}", create_table_query=CREATE_LIGHT_SUBSPACE_TABLE % TABLE_NAME, - insert_record_query=INSERT_LIGHT_SUBSPACE % TABLE_NAME + insert_record_query=INSERT_LIGHT_SUBSPACE % TABLE_NAME, ) def get_record_info(self): @@ -51,9 +51,9 @@ def get_record_info(self): return RECORD_HELP def _get_weak_foreign_key_value(self, record): - associate_table = getattr_either("level_3_lighting_definition_table", record), + associate_table = (getattr_either("level_3_lighting_definition_table", record),) key = "id" - value = getattr_either("level_3_lighting_definition_id", record), + value = (getattr_either("level_3_lighting_definition_id", record),) return associate_table, key, value def _preprocess_record(self, record): @@ -69,4 +69,3 @@ def _preprocess_record(self, record): ) return record_list - diff --git a/data/openstudio_standards_data/database_tables/level_2_ventilation_space_types.py b/data/openstudio_standards_data/database_tables/level_2_ventilation_space_types.py index 05fa9e7f7e..4494a1b41a 100644 --- a/data/openstudio_standards_data/database_tables/level_2_ventilation_space_types.py +++ b/data/openstudio_standards_data/database_tables/level_2_ventilation_space_types.py @@ -41,7 +41,7 @@ def __init__(self): record_template=RECORD_TEMPLATE, initial_data_directory=f"database_files/{TABLE_NAME}", create_table_query=CREATE_VENT_SUBSPACE_TABLE % TABLE_NAME, - insert_record_query=INSERT_VENT_SUBSPACE % TABLE_NAME + insert_record_query=INSERT_VENT_SUBSPACE % TABLE_NAME, ) def get_record_info(self): @@ -52,9 +52,11 @@ def get_record_info(self): return RECORD_HELP def _get_weak_foreign_key_value(self, record): - associate_table = getattr_either("level_3_ventilation_definition_table", record), + associate_table = ( + getattr_either("level_3_ventilation_definition_table", record), + ) key = "id" - value = getattr_either("level_3_ventilation_definition_id", record), + value = (getattr_either("level_3_ventilation_definition_id", record),) return associate_table, key, value def _preprocess_record(self, record): @@ -71,4 +73,3 @@ def _preprocess_record(self, record): ) return record_list - diff --git a/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_definition.py b/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_definition.py index e840f388d7..9d28051f33 100644 --- a/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_definition.py +++ b/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_definition.py @@ -47,7 +47,7 @@ def __init__(self, table_name, initial_data_directory): record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, create_table_query=CREATE_LIGHT_DEF_90_1_TABLE % table_name, - insert_record_query=INSERT_A_LIGHT_RECORD % table_name + insert_record_query=INSERT_A_LIGHT_RECORD % table_name, ) def get_record_info(self): @@ -84,4 +84,3 @@ def _preprocess_record(self, record): getattr_either("annotation", record, ""), ) return record_tuple - diff --git a/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_definition.py b/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_definition.py index 2033392ac4..ece0e31df3 100644 --- a/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_definition.py +++ b/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_definition.py @@ -63,7 +63,7 @@ def __init__(self, table_name, initial_data_directory): record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, create_table_query=CREATE_VENT_DEF_62_1_TABLE % table_name, - insert_record_query=INSERT_A_VENT_RECORD % table_name + insert_record_query=INSERT_A_VENT_RECORD % table_name, ) def get_record_info(self): @@ -106,4 +106,3 @@ def _preprocess_record(self, record): getattr_either("os", record), getattr_either("annotation", record, ""), ) - diff --git a/data/openstudio_standards_data/database_tables/support_constructions.py b/data/openstudio_standards_data/database_tables/support_constructions.py index 1a826ab240..64883e21b3 100644 --- a/data/openstudio_standards_data/database_tables/support_constructions.py +++ b/data/openstudio_standards_data/database_tables/support_constructions.py @@ -79,7 +79,7 @@ def __init__(self): record_template=RECORD_TEMPLATE, initial_data_directory=f"database_files/{TABLE_NAME}", create_table_query=CREATE_CONSTRUCTIONS_TABLE % TABLE_NAME, - insert_record_query=INSERT_CONSTRUCTION % TABLE_NAME + insert_record_query=INSERT_CONSTRUCTION % TABLE_NAME, ) def get_record_info(self): @@ -130,4 +130,3 @@ def _preprocess_record(self, record): getattr_either("material_5", record), getattr_either("material_6", record), ) - diff --git a/data/openstudio_standards_data/database_tables/support_electric_equipment_space_type_name_tags.py b/data/openstudio_standards_data/database_tables/support_electric_equipment_space_type_name_tags.py index c6bc568829..fedb29f9cd 100644 --- a/data/openstudio_standards_data/database_tables/support_electric_equipment_space_type_name_tags.py +++ b/data/openstudio_standards_data/database_tables/support_electric_equipment_space_type_name_tags.py @@ -33,8 +33,9 @@ def __init__(self): table_name=TABLE_NAME, record_template=RECORD_TEMPLATE, initial_data_directory=f"database_files/{TABLE_NAME}", - create_table_query=CREATE_SUPPORT_ELECTRIC_EQUIPMENT_SPACE_TYPE_NAME_TAGS % TABLE_NAME, - insert_record_query=INSERT_SPACE_TAG % TABLE_NAME + create_table_query=CREATE_SUPPORT_ELECTRIC_EQUIPMENT_SPACE_TYPE_NAME_TAGS + % TABLE_NAME, + insert_record_query=INSERT_SPACE_TAG % TABLE_NAME, ) def get_record_info(self): diff --git a/data/openstudio_standards_data/database_tables/support_lighting_space_type_name_tags.py b/data/openstudio_standards_data/database_tables/support_lighting_space_type_name_tags.py index eb5bdd7383..daa03fb2c4 100644 --- a/data/openstudio_standards_data/database_tables/support_lighting_space_type_name_tags.py +++ b/data/openstudio_standards_data/database_tables/support_lighting_space_type_name_tags.py @@ -34,7 +34,7 @@ def __init__(self): record_template=RECORD_TEMPLATE, initial_data_directory=f"database_files/{TABLE_NAME}", create_table_query=CREATE_LIGHTING_SPACE_TAG % TABLE_NAME, - insert_record_query=INSERT_SPACE_TAG % TABLE_NAME + insert_record_query=INSERT_SPACE_TAG % TABLE_NAME, ) def get_record_info(self): @@ -51,4 +51,3 @@ def _preprocess_record(self, record): :return: """ return (getattr_either("lighting_space_type_name", record),) - diff --git a/data/openstudio_standards_data/database_tables/support_materials.py b/data/openstudio_standards_data/database_tables/support_materials.py index 5290963945..763cc1731f 100644 --- a/data/openstudio_standards_data/database_tables/support_materials.py +++ b/data/openstudio_standards_data/database_tables/support_materials.py @@ -145,7 +145,7 @@ def __init__(self): record_template=RECORD_TEMPLATE, initial_data_directory=f"database_files/{TABLE_NAME}", create_table_query=CREATE_MATERIALS_TABLE % TABLE_NAME, - insert_record_query=INSERT_MATERIAL % TABLE_NAME + insert_record_query=INSERT_MATERIAL % TABLE_NAME, ) def get_record_info(self): diff --git a/data/openstudio_standards_data/database_tables/support_performance_curves.py b/data/openstudio_standards_data/database_tables/support_performance_curves.py index 6863ee60d8..9f5ddb64bf 100644 --- a/data/openstudio_standards_data/database_tables/support_performance_curves.py +++ b/data/openstudio_standards_data/database_tables/support_performance_curves.py @@ -125,7 +125,7 @@ def __init__(self): record_template=RECORD_TEMPLATE, initial_data_directory=f"database_files/{TABLE_NAME}", create_table_query=CREATE_PERFORMANCE_CURVES_TABLE % TABLE_NAME, - insert_record_query=INSERT_PERFORMANCE_CURVE % TABLE_NAME + insert_record_query=INSERT_PERFORMANCE_CURVE % TABLE_NAME, ) def get_record_info(self): @@ -206,4 +206,3 @@ def _preprocess_record(self, record): getattr_either("maximum_dependent_variable_output", record), getattr_either("annotation", record), ) - diff --git a/data/openstudio_standards_data/database_tables/support_standard_templates.py b/data/openstudio_standards_data/database_tables/support_standard_templates.py index 6f35554820..3b85490e38 100644 --- a/data/openstudio_standards_data/database_tables/support_standard_templates.py +++ b/data/openstudio_standards_data/database_tables/support_standard_templates.py @@ -44,7 +44,7 @@ def __init__(self): record_template=RECORD_TEMPLATE, initial_data_directory=f"database_files/{TABLE_NAME}", create_table_query=CREATE_SUPPORT_STANDARD_TEMPLATES % TABLE_NAME, - insert_record_query=INSERT_A_TEMPLATE_RECORD % TABLE_NAME + insert_record_query=INSERT_A_TEMPLATE_RECORD % TABLE_NAME, ) def get_record_info(self): @@ -68,4 +68,3 @@ def _preprocess_record(self, record): getattr_either("ventilation_standard", record), getattr_either("ventilation_standard_table", record), ) - diff --git a/data/openstudio_standards_data/database_tables/support_ventilation_space_type_name_tags.py b/data/openstudio_standards_data/database_tables/support_ventilation_space_type_name_tags.py index b705ff58a8..12e21e2c9c 100644 --- a/data/openstudio_standards_data/database_tables/support_ventilation_space_type_name_tags.py +++ b/data/openstudio_standards_data/database_tables/support_ventilation_space_type_name_tags.py @@ -34,7 +34,7 @@ def __init__(self): record_template=RECORD_TEMPLATE, initial_data_directory=f"database_files/{TABLE_NAME}", create_table_query=CREATE_VENTILATION_SPACE_TYPE_NAME % TABLE_NAME, - insert_record_query=INSERT_SPACE_TAG % TABLE_NAME + insert_record_query=INSERT_SPACE_TAG % TABLE_NAME, ) def get_record_info(self): @@ -52,4 +52,3 @@ def _preprocess_record(self, record): """ return (getattr_either("ventilation_space_type_name", record),) - diff --git a/data/openstudio_standards_data/database_tables/system_requirement_economizer.py b/data/openstudio_standards_data/database_tables/system_requirement_economizer.py index 784dea57d1..51b8602cc5 100644 --- a/data/openstudio_standards_data/database_tables/system_requirement_economizer.py +++ b/data/openstudio_standards_data/database_tables/system_requirement_economizer.py @@ -51,7 +51,7 @@ def __init__(self, table_name, initial_data_directory): record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, create_table_query=CREATE_SYSTEM_REQUIREMENT_ECONOMIZER_TABLE % table_name, - insert_record_query=INSERT_A_SYSTEM_REQUIREMENT_ECONOMIZER % table_name + insert_record_query=INSERT_A_SYSTEM_REQUIREMENT_ECONOMIZER % table_name, ) def get_record_info(self): diff --git a/data/openstudio_standards_data/database_tables/system_requirement_energy_recovery.py b/data/openstudio_standards_data/database_tables/system_requirement_energy_recovery.py index 9f5fb48b2b..44a3fc9e4c 100644 --- a/data/openstudio_standards_data/database_tables/system_requirement_energy_recovery.py +++ b/data/openstudio_standards_data/database_tables/system_requirement_energy_recovery.py @@ -90,8 +90,10 @@ def __init__(self, table_name, initial_data_directory): table_name=table_name, record_template=RECORD_TEMPLATE, initial_data_directory=initial_data_directory, - create_table_query=CREATE_SYSTEM_REQUIREMENT_ENERGY_RECOVERY_TABLE % table_name, - insert_record_query=INSERT_A_SYSTEM_REQUIREMENT_ENERGY_RECOVERY_RECORD % table_name + create_table_query=CREATE_SYSTEM_REQUIREMENT_ENERGY_RECOVERY_TABLE + % table_name, + insert_record_query=INSERT_A_SYSTEM_REQUIREMENT_ENERGY_RECOVERY_RECORD + % table_name, ) def get_record_info(self): @@ -160,4 +162,3 @@ def _preprocess_record(self, record): getattr_either("enthalpy_recovery_ratio", record), getattr_either("annotation", record), ) - diff --git a/data/openstudio_standards_data/query/util.py b/data/openstudio_standards_data/query/util.py index 6d04e95a6a..6b0852f433 100644 --- a/data/openstudio_standards_data/query/util.py +++ b/data/openstudio_standards_data/query/util.py @@ -22,7 +22,9 @@ def _convert_tuple_to_dict(data: tuple, data_head_list: List[str]): return dict(zip(data_head_list, data)) -def is_index_in_table(conn: sqlite3.Connection, table_name: str | None, key: str | None, index: str | None): +def is_index_in_table( + conn: sqlite3.Connection, table_name: str | None, key: str | None, index: str | None +): """ Utility function to ensure the index exist in a table. :param conn: sqlite3 connection diff --git a/data/openstudio_standards_data/test/test_database.py b/data/openstudio_standards_data/test/test_database.py index 21839e3f22..568bcc0dc9 100644 --- a/data/openstudio_standards_data/test/test_database.py +++ b/data/openstudio_standards_data/test/test_database.py @@ -42,13 +42,11 @@ def __init__(self): record_template={}, initial_data_directory="", create_table_query=CREATE_L3_TEST_TABLE, - insert_record_query=INSERT_L3_TEST_TABLE + insert_record_query=INSERT_L3_TEST_TABLE, ) def _preprocess_record(self, record): - return ( - record["name"], - ) + return (record["name"],) class SampleL2TestTable(DBOperation): @@ -58,14 +56,11 @@ def __init__(self): record_template={}, initial_data_directory="", create_table_query=CREATE_L2_TABLE, - insert_record_query=INSERT_L2_TABLE + insert_record_query=INSERT_L2_TABLE, ) def _preprocess_record(self, record): - return ( - record["associate_table"], - record["foreign_key"] - ) + return (record["associate_table"], record["foreign_key"]) def _get_weak_foreign_key_value(self, record): return record["associate_table"], "id", record["foreign_key"] @@ -80,8 +75,8 @@ def setUp(self): self.level_3_table = SampleL3TestTable() self.level_2_table.create_a_table(self.conn) self.level_3_table.create_a_table(self.conn) - self.level_3_table.add_a_record(self.conn, {"name":"test_value_1"}) # index 1 - self.level_3_table.add_a_record(self.conn, {"name":"test_value_2"}) # index 2 + self.level_3_table.add_a_record(self.conn, {"name": "test_value_1"}) # index 1 + self.level_3_table.add_a_record(self.conn, {"name": "test_value_2"}) # index 2 def tearDown(self): # close the database connection @@ -90,17 +85,23 @@ def tearDown(self): def test_index_exists(self): # Test that the function correctly identifies an existing index - add_success = self.level_2_table.add_a_record(self.conn, {"associate_table": "level_3_table", "foreign_key": "1"}) + add_success = self.level_2_table.add_a_record( + self.conn, {"associate_table": "level_3_table", "foreign_key": "1"} + ) self.assertTrue(add_success) def test_index_does_not_exist(self): # Test that the function validated the index is not exist - add_success = self.level_2_table.add_a_record(self.conn, {"associate_table": "level_3_table", "foreign_key": "3"}) + add_success = self.level_2_table.add_a_record( + self.conn, {"associate_table": "level_3_table", "foreign_key": "3"} + ) self.assertFalse(add_success) def test_table_does_not_exist(self): # Test if the table is not exist - add_success = self.level_2_table.add_a_record(self.conn, {"associate_table": "missing_table", "foreign_key": "1"}) + add_success = self.level_2_table.add_a_record( + self.conn, {"associate_table": "missing_table", "foreign_key": "1"} + ) self.assertFalse(add_success) From d3fdc8c5762aa51ce99b2e887b1f7f7c2c8cf6f6 Mon Sep 17 00:00:00 2001 From: Weili Xu Date: Tue, 28 Mar 2023 11:12:18 -0700 Subject: [PATCH 13/45] add pipfile lock --- data/openstudio_standards_data/Pipfile.lock | 281 ++++++++++++++++++++ 1 file changed, 281 insertions(+) create mode 100644 data/openstudio_standards_data/Pipfile.lock diff --git a/data/openstudio_standards_data/Pipfile.lock b/data/openstudio_standards_data/Pipfile.lock new file mode 100644 index 0000000000..8ca6587c74 --- /dev/null +++ b/data/openstudio_standards_data/Pipfile.lock @@ -0,0 +1,281 @@ +{ + "_meta": { + "hash": { + "sha256": "8ce59fe81cf863b2197b2f755c3c40c7544bce0aed72fcf72933595a7de8e9a4" + }, + "pipfile-spec": 6, + "requires": { + "python_version": "3.10" + }, + "sources": [ + { + "name": "pypi", + "url": "https://pypi.org/simple", + "verify_ssl": true + } + ] + }, + "default": { + "attrs": { + "hashes": [ + "sha256:29e95c7f6778868dbd49170f98f8818f78f3dc5e0e37c0b1f474e3561b240836", + "sha256:c9227bfc2f01993c03f68db37d1d15c9690188323c067c641f1a35ca58185f99" + ], + "markers": "python_version >= '3.6'", + "version": "==22.2.0" + }, + "black": { + "hashes": [ + "sha256:0052dba51dec07ed029ed61b18183942043e00008ec65d5028814afaab9a22fd", + "sha256:0680d4380db3719ebcfb2613f34e86c8e6d15ffeabcf8ec59355c5e7b85bb555", + "sha256:121ca7f10b4a01fd99951234abdbd97728e1240be89fde18480ffac16503d481", + "sha256:162e37d49e93bd6eb6f1afc3e17a3d23a823042530c37c3c42eeeaf026f38468", + "sha256:2a951cc83ab535d248c89f300eccbd625e80ab880fbcfb5ac8afb5f01a258ac9", + "sha256:2bf649fda611c8550ca9d7592b69f0637218c2369b7744694c5e4902873b2f3a", + "sha256:382998821f58e5c8238d3166c492139573325287820963d2f7de4d518bd76958", + "sha256:49f7b39e30f326a34b5c9a4213213a6b221d7ae9d58ec70df1c4a307cf2a1580", + "sha256:57c18c5165c1dbe291d5306e53fb3988122890e57bd9b3dcb75f967f13411a26", + "sha256:7a0f701d314cfa0896b9001df70a530eb2472babb76086344e688829efd97d32", + "sha256:8178318cb74f98bc571eef19068f6ab5613b3e59d4f47771582f04e175570ed8", + "sha256:8b70eb40a78dfac24842458476135f9b99ab952dd3f2dab738c1881a9b38b753", + "sha256:9880d7d419bb7e709b37e28deb5e68a49227713b623c72b2b931028ea65f619b", + "sha256:9afd3f493666a0cd8f8df9a0200c6359ac53940cbde049dcb1a7eb6ee2dd7074", + "sha256:a29650759a6a0944e7cca036674655c2f0f63806ddecc45ed40b7b8aa314b651", + "sha256:a436e7881d33acaf2536c46a454bb964a50eff59b21b51c6ccf5a40601fbef24", + "sha256:a59db0a2094d2259c554676403fa2fac3473ccf1354c1c63eccf7ae65aac8ab6", + "sha256:a8471939da5e824b891b25751955be52ee7f8a30a916d570a5ba8e0f2eb2ecad", + "sha256:b0bd97bea8903f5a2ba7219257a44e3f1f9d00073d6cc1add68f0beec69692ac", + "sha256:b6a92a41ee34b883b359998f0c8e6eb8e99803aa8bf3123bf2b2e6fec505a221", + "sha256:bb460c8561c8c1bec7824ecbc3ce085eb50005883a6203dcfb0122e95797ee06", + "sha256:bfffba28dc52a58f04492181392ee380e95262af14ee01d4bc7bb1b1c6ca8d27", + "sha256:c1c476bc7b7d021321e7d93dc2cbd78ce103b84d5a4cf97ed535fbc0d6660648", + "sha256:c91dfc2c2a4e50df0026f88d2215e166616e0c80e86004d0003ece0488db2739", + "sha256:e6663f91b6feca5d06f2ccd49a10f254f9298cc1f7f49c46e498a0771b507104" + ], + "index": "pypi", + "version": "==23.1.0" + }, + "click": { + "hashes": [ + "sha256:7682dc8afb30297001674575ea00d1814d808d6a36af415a82bd481d37ba7b8e", + "sha256:bb4d8133cb15a609f44e8213d9b391b0809795062913b383c62be0ee95b1db48" + ], + "markers": "python_version >= '3.7'", + "version": "==8.1.3" + }, + "colorama": { + "hashes": [ + "sha256:08695f5cb7ed6e0531a20572697297273c47b8cae5a63ffc6d6ed5c201be6e44", + "sha256:4f1d9991f5acc0ca119f9d443620b77f9d6b33703e51011c16baf57afb285fc6" + ], + "markers": "sys_platform == 'win32'", + "version": "==0.4.6" + }, + "exceptiongroup": { + "hashes": [ + "sha256:232c37c63e4f682982c8b6459f33a8981039e5fb8756b2074364e5055c498c9e", + "sha256:d484c3090ba2889ae2928419117447a14daf3c1231d5e30d0aae34f354f01785" + ], + "markers": "python_version < '3.11'", + "version": "==1.1.1" + }, + "iniconfig": { + "hashes": [ + "sha256:2d91e135bf72d31a410b17c16da610a82cb55f6b0477d1a902134b24a455b8b3", + "sha256:b6a85871a79d2e3b22d2d1b94ac2824226a63c6b741c88f7ae975f18b6778374" + ], + "markers": "python_version >= '3.7'", + "version": "==2.0.0" + }, + "mypy-extensions": { + "hashes": [ + "sha256:4392f6c0eb8a5668a69e23d168ffa70f0be9ccfd32b5cc2d26a34ae5b844552d", + "sha256:75dbf8955dc00442a438fc4d0666508a9a97b6bd41aa2f0ffe9d2f2725af0782" + ], + "markers": "python_version >= '3.5'", + "version": "==1.0.0" + }, + "packaging": { + "hashes": [ + "sha256:714ac14496c3e68c99c29b00845f7a2b85f3bb6f1078fd9f72fd20f0570002b2", + "sha256:b6ad297f8907de0fa2fe1ccbd26fdaf387f5f47c7275fedf8cce89f99446cf97" + ], + "markers": "python_version >= '3.7'", + "version": "==23.0" + }, + "pathspec": { + "hashes": [ + "sha256:2798de800fa92780e33acca925945e9a19a133b715067cf165b8866c15a31687", + "sha256:d8af70af76652554bd134c22b3e8a1cc46ed7d91edcdd721ef1a0c51a84a5293" + ], + "markers": "python_version >= '3.7'", + "version": "==0.11.1" + }, + "platformdirs": { + "hashes": [ + "sha256:d5b638ca397f25f979350ff789db335903d7ea010ab28903f57b27e1b16c2b08", + "sha256:ebe11c0d7a805086e99506aa331612429a72ca7cd52a1f0d277dc4adc20cb10e" + ], + "markers": "python_version >= '3.7'", + "version": "==3.2.0" + }, + "pluggy": { + "hashes": [ + "sha256:4224373bacce55f955a878bf9cfa763c1e360858e330072059e10bad68531159", + "sha256:74134bbf457f031a36d68416e1509f34bd5ccc019f0bcc952c7b909d06b37bd3" + ], + "markers": "python_version >= '3.6'", + "version": "==1.0.0" + }, + "pytest": { + "hashes": [ + "sha256:130328f552dcfac0b1cec75c12e3f005619dc5f874f0a06e8ff7263f0ee6225e", + "sha256:c99ab0c73aceb050f68929bc93af19ab6db0558791c6a0715723abe9d0ade9d4" + ], + "index": "pypi", + "version": "==7.2.2" + }, + "tomli": { + "hashes": [ + "sha256:939de3e7a6161af0c887ef91b7d41a53e7c5a1ca976325f429cb46ea9bc30ecc", + "sha256:de526c12914f0c550d15924c62d72abc48d6fe7364aa87328337a31007fe8a4f" + ], + "markers": "python_version < '3.11'", + "version": "==2.0.1" + } + }, + "develop": { + "attrs": { + "hashes": [ + "sha256:29e95c7f6778868dbd49170f98f8818f78f3dc5e0e37c0b1f474e3561b240836", + "sha256:c9227bfc2f01993c03f68db37d1d15c9690188323c067c641f1a35ca58185f99" + ], + "markers": "python_version >= '3.6'", + "version": "==22.2.0" + }, + "colorama": { + "hashes": [ + "sha256:08695f5cb7ed6e0531a20572697297273c47b8cae5a63ffc6d6ed5c201be6e44", + "sha256:4f1d9991f5acc0ca119f9d443620b77f9d6b33703e51011c16baf57afb285fc6" + ], + "markers": "sys_platform == 'win32'", + "version": "==0.4.6" + }, + "coverage": { + "extras": [ + "toml" + ], + "hashes": [ + "sha256:006ed5582e9cbc8115d2e22d6d2144a0725db542f654d9d4fda86793832f873d", + "sha256:046936ab032a2810dcaafd39cc4ef6dd295df1a7cbead08fe996d4765fca9fe4", + "sha256:0484d9dd1e6f481b24070c87561c8d7151bdd8b044c93ac99faafd01f695c78e", + "sha256:0ce383d5f56d0729d2dd40e53fe3afeb8f2237244b0975e1427bfb2cf0d32bab", + "sha256:186e0fc9cf497365036d51d4d2ab76113fb74f729bd25da0975daab2e107fd90", + "sha256:2199988e0bc8325d941b209f4fd1c6fa007024b1442c5576f1a32ca2e48941e6", + "sha256:299bc75cb2a41e6741b5e470b8c9fb78d931edbd0cd009c58e5c84de57c06731", + "sha256:3668291b50b69a0c1ef9f462c7df2c235da3c4073f49543b01e7eb1dee7dd540", + "sha256:36dd42da34fe94ed98c39887b86db9d06777b1c8f860520e21126a75507024f2", + "sha256:38004671848b5745bb05d4d621526fca30cee164db42a1f185615f39dc997292", + "sha256:387fb46cb8e53ba7304d80aadca5dca84a2fbf6fe3faf6951d8cf2d46485d1e5", + "sha256:3eb55b7b26389dd4f8ae911ba9bc8c027411163839dea4c8b8be54c4ee9ae10b", + "sha256:420f94a35e3e00a2b43ad5740f935358e24478354ce41c99407cddd283be00d2", + "sha256:4ac0f522c3b6109c4b764ffec71bf04ebc0523e926ca7cbe6c5ac88f84faced0", + "sha256:4c752d5264053a7cf2fe81c9e14f8a4fb261370a7bb344c2a011836a96fb3f57", + "sha256:4f01911c010122f49a3e9bdc730eccc66f9b72bd410a3a9d3cb8448bb50d65d3", + "sha256:4f68ee32d7c4164f1e2c8797535a6d0a3733355f5861e0f667e37df2d4b07140", + "sha256:4fa54fb483decc45f94011898727802309a109d89446a3c76387d016057d2c84", + "sha256:507e4720791977934bba016101579b8c500fb21c5fa3cd4cf256477331ddd988", + "sha256:53d0fd4c17175aded9c633e319360d41a1f3c6e352ba94edcb0fa5167e2bad67", + "sha256:55272f33da9a5d7cccd3774aeca7a01e500a614eaea2a77091e9be000ecd401d", + "sha256:5764e1f7471cb8f64b8cda0554f3d4c4085ae4b417bfeab236799863703e5de2", + "sha256:57b77b9099f172804e695a40ebaa374f79e4fb8b92f3e167f66facbf92e8e7f5", + "sha256:5afdad4cc4cc199fdf3e18088812edcf8f4c5a3c8e6cb69127513ad4cb7471a9", + "sha256:5cc0783844c84af2522e3a99b9b761a979a3ef10fb87fc4048d1ee174e18a7d8", + "sha256:5e1df45c23d4230e3d56d04414f9057eba501f78db60d4eeecfcb940501b08fd", + "sha256:6146910231ece63facfc5984234ad1b06a36cecc9fd0c028e59ac7c9b18c38c6", + "sha256:797aad79e7b6182cb49c08cc5d2f7aa7b2128133b0926060d0a8889ac43843be", + "sha256:7c20b731211261dc9739bbe080c579a1835b0c2d9b274e5fcd903c3a7821cf88", + "sha256:817295f06eacdc8623dc4df7d8b49cea65925030d4e1e2a7c7218380c0072c25", + "sha256:81f63e0fb74effd5be736cfe07d710307cc0a3ccb8f4741f7f053c057615a137", + "sha256:872d6ce1f5be73f05bea4df498c140b9e7ee5418bfa2cc8204e7f9b817caa968", + "sha256:8c99cb7c26a3039a8a4ee3ca1efdde471e61b4837108847fb7d5be7789ed8fd9", + "sha256:8dbe2647bf58d2c5a6c5bcc685f23b5f371909a5624e9f5cd51436d6a9f6c6ef", + "sha256:8efb48fa743d1c1a65ee8787b5b552681610f06c40a40b7ef94a5b517d885c54", + "sha256:92ebc1619650409da324d001b3a36f14f63644c7f0a588e331f3b0f67491f512", + "sha256:9d22e94e6dc86de981b1b684b342bec5e331401599ce652900ec59db52940005", + "sha256:ba279aae162b20444881fc3ed4e4f934c1cf8620f3dab3b531480cf602c76b7f", + "sha256:bc4803779f0e4b06a2361f666e76f5c2e3715e8e379889d02251ec911befd149", + "sha256:bfe7085783cda55e53510482fa7b5efc761fad1abe4d653b32710eb548ebdd2d", + "sha256:c448b5c9e3df5448a362208b8d4b9ed85305528313fca1b479f14f9fe0d873b8", + "sha256:c90e73bdecb7b0d1cea65a08cb41e9d672ac6d7995603d6465ed4914b98b9ad7", + "sha256:d2b96123a453a2d7f3995ddb9f28d01fd112319a7a4d5ca99796a7ff43f02af5", + "sha256:d52f0a114b6a58305b11a5cdecd42b2e7f1ec77eb20e2b33969d702feafdd016", + "sha256:d530191aa9c66ab4f190be8ac8cc7cfd8f4f3217da379606f3dd4e3d83feba69", + "sha256:d683d230b5774816e7d784d7ed8444f2a40e7a450e5720d58af593cb0b94a212", + "sha256:db45eec1dfccdadb179b0f9ca616872c6f700d23945ecc8f21bb105d74b1c5fc", + "sha256:db8c2c5ace167fd25ab5dd732714c51d4633f58bac21fb0ff63b0349f62755a8", + "sha256:e2926b8abedf750c2ecf5035c07515770944acf02e1c46ab08f6348d24c5f94d", + "sha256:e627dee428a176ffb13697a2c4318d3f60b2ccdde3acdc9b3f304206ec130ccd", + "sha256:efe1c0adad110bf0ad7fb59f833880e489a61e39d699d37249bdf42f80590169" + ], + "markers": "python_version >= '3.7'", + "version": "==7.2.2" + }, + "exceptiongroup": { + "hashes": [ + "sha256:232c37c63e4f682982c8b6459f33a8981039e5fb8756b2074364e5055c498c9e", + "sha256:d484c3090ba2889ae2928419117447a14daf3c1231d5e30d0aae34f354f01785" + ], + "markers": "python_version < '3.11'", + "version": "==1.1.1" + }, + "iniconfig": { + "hashes": [ + "sha256:2d91e135bf72d31a410b17c16da610a82cb55f6b0477d1a902134b24a455b8b3", + "sha256:b6a85871a79d2e3b22d2d1b94ac2824226a63c6b741c88f7ae975f18b6778374" + ], + "markers": "python_version >= '3.7'", + "version": "==2.0.0" + }, + "packaging": { + "hashes": [ + "sha256:714ac14496c3e68c99c29b00845f7a2b85f3bb6f1078fd9f72fd20f0570002b2", + "sha256:b6ad297f8907de0fa2fe1ccbd26fdaf387f5f47c7275fedf8cce89f99446cf97" + ], + "markers": "python_version >= '3.7'", + "version": "==23.0" + }, + "pluggy": { + "hashes": [ + "sha256:4224373bacce55f955a878bf9cfa763c1e360858e330072059e10bad68531159", + "sha256:74134bbf457f031a36d68416e1509f34bd5ccc019f0bcc952c7b909d06b37bd3" + ], + "markers": "python_version >= '3.6'", + "version": "==1.0.0" + }, + "pytest": { + "hashes": [ + "sha256:130328f552dcfac0b1cec75c12e3f005619dc5f874f0a06e8ff7263f0ee6225e", + "sha256:c99ab0c73aceb050f68929bc93af19ab6db0558791c6a0715723abe9d0ade9d4" + ], + "index": "pypi", + "version": "==7.2.2" + }, + "pytest-cov": { + "hashes": [ + "sha256:2feb1b751d66a8bd934e5edfa2e961d11309dc37b73b0eabe73b5945fee20f6b", + "sha256:996b79efde6433cdbd0088872dbc5fb3ed7fe1578b68cdbba634f14bb8dd0470" + ], + "index": "pypi", + "version": "==4.0.0" + }, + "tomli": { + "hashes": [ + "sha256:939de3e7a6161af0c887ef91b7d41a53e7c5a1ca976325f429cb46ea9bc30ecc", + "sha256:de526c12914f0c550d15924c62d72abc48d6fe7364aa87328337a31007fe8a4f" + ], + "markers": "python_version < '3.11'", + "version": "==2.0.1" + } + } +} From 512285e776badf87b185dc9ba66fbb5d6fb770a6 Mon Sep 17 00:00:00 2001 From: Weili Xu Date: Tue, 28 Mar 2023 13:15:31 -0700 Subject: [PATCH 14/45] Add boolean return value to the valid data type check --- .../applications/database_maintenance.py | 11 +++++++++-- .../hvac_minimum_requirement_boilers.py | 1 + .../hvac_minimum_requirement_chillers.py | 1 + .../hvac_minimum_requirement_furnaces.py | 1 + .../hvac_minimum_requirement_heat_pump_cooling.py | 1 + .../hvac_minimum_requirement_heat_pump_heating.py | 1 + .../hvac_minimum_requirement_heat_rejection.py | 1 + .../hvac_minimum_requirement_motors.py | 1 + ...ac_minimum_requirement_unitary_air_conditioners.py | 1 + .../hvac_minimum_requirement_water_heaters.py | 1 + ...mum_requirement_water_source_heat_pumps_cooling.py | 1 + ...mum_requirement_water_source_heat_pumps_heating.py | 1 + .../database_tables/level_2_electric_equipment.py | 1 + .../database_tables/level_2_lighting_space_types.py | 4 ++-- .../level_2_ventilation_space_types.py | 7 ++----- .../level_3_lighting_90_1_definition.py | 1 + .../level_3_ventilation_62_1_definition.py | 1 + .../database_tables/support_constructions.py | 1 + .../database_tables/support_materials.py | 1 + .../database_tables/support_performance_curves.py | 1 + .../database_tables/system_requirement_economizer.py | 1 + .../system_requirement_energy_recovery.py | 1 + 22 files changed, 32 insertions(+), 9 deletions(-) diff --git a/data/openstudio_standards_data/applications/database_maintenance.py b/data/openstudio_standards_data/applications/database_maintenance.py index 395bf4a446..6574b22a57 100644 --- a/data/openstudio_standards_data/applications/database_maintenance.py +++ b/data/openstudio_standards_data/applications/database_maintenance.py @@ -2,6 +2,7 @@ import logging import database_tables as tables +from database_engine.assertions import assert_ from database_engine.database_util import read_csv_to_list_dict, read_json_to_list_dict @@ -14,7 +15,10 @@ def create_openstudio_standards_database_from_csv(conn: sqlite3.Connection): data = read_csv_to_list_dict(f"{datatable.initial_data_directory}.csv") for record in data: logging.info(record) - logging.info(datatable.add_a_record(conn, record)) + assert_( + datatable.add_a_record(conn, record), + f"Unsuccessful adding a new record: {record} to table {datatable.data_table_name}", + ) def create_openstudio_standards_database_from_json(conn: sqlite3.Connection): @@ -26,7 +30,10 @@ def create_openstudio_standards_database_from_json(conn: sqlite3.Connection): data = read_json_to_list_dict(f"{datatable.initial_data_directory}.json") for record in data: logging.info(record) - logging.info(datatable.add_a_record(conn, record)) + assert_( + datatable.add_a_record(conn, record), + f"Unsuccessful adding a new record: {record} to table {datatable.data_table_name}", + ) def export_openstudio_standards_database_to_csv(conn: sqlite3.Connection, save_dir=""): diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_boilers.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_boilers.py index 4c3d8da13f..7c86262760 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_boilers.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_boilers.py @@ -123,6 +123,7 @@ def validate_record_datatype(self, record): assert is_float( record.get(f) ), f"{f} requires to be numeric data type, instead got {record[f]}" + return True def _preprocess_record(self, record): """ diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_chillers.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_chillers.py index b1e51d92c1..36f3deb15b 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_chillers.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_chillers.py @@ -134,6 +134,7 @@ def validate_record_datatype(self, record): assert is_float( record.get(f) ), f"{f} requires to be numeric data type, instead got {record[f]}" + return True def _preprocess_record(self, record): """ diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_furnaces.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_furnaces.py index 823d86b060..122cada04e 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_furnaces.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_furnaces.py @@ -99,6 +99,7 @@ def validate_record_datatype(self, record): assert is_float( record.get(f) ), f"{f} requires to be numeric data type, instead got {record[f]}" + return True def _preprocess_record(self, record): """ diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_cooling.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_cooling.py index e142337066..2267d90526 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_cooling.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_cooling.py @@ -155,6 +155,7 @@ def validate_record_datatype(self, record): assert is_float( record.get(f) ), f"{f} requires to be numeric data type, instead got {record[f]}" + return True def _preprocess_record(self, record): """ diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_heating.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_heating.py index e95ab28dbf..295c79ec88 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_heating.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_pump_heating.py @@ -145,6 +145,7 @@ def validate_record_datatype(self, record): assert is_float( record.get(f) ), f"{f} requires to be numeric data type, instead got {record[f]}" + return True def _preprocess_record(self, record): """ diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_rejection.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_rejection.py index f1c5d3cf97..205dd01e1e 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_rejection.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_heat_rejection.py @@ -85,6 +85,7 @@ def validate_record_datatype(self, record): assert is_float( record.get("minimum_performance_gpm_per_hp") ), f"minimum_performance_gpm_per_hp requires to be numeric data type, instead got {record['minimum_performance_gpm_per_hp']}" + return True def _preprocess_record(self, record): """ diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_motors.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_motors.py index 80f789eb3f..6f37f943a7 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_motors.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_motors.py @@ -94,6 +94,7 @@ def validate_record_datatype(self, record): assert is_float( record.get(f) ), f"{f} requires to be numeric data type, instead got {record[f]}" + return True def _preprocess_record(self, record): """ diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_unitary_air_conditioners.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_unitary_air_conditioners.py index e1b822b876..dec3977092 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_unitary_air_conditioners.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_unitary_air_conditioners.py @@ -158,6 +158,7 @@ def validate_record_datatype(self, record): assert is_float( record.get(f) ), f"{f} requires to be numeric data type, instead got {record[f]}" + return True def _preprocess_record(self, record): """ diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_heaters.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_heaters.py index 67fca268c5..5a2e4ddac0 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_heaters.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_heaters.py @@ -129,6 +129,7 @@ def validate_record_datatype(self, record): assert is_float( record.get(f) ), f"{f} requires to be numeric data type, instead got {record[f]}" + return True def _preprocess_record(self, record): """ diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_cooling.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_cooling.py index 7c52dc6fca..f7e01b159d 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_cooling.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_cooling.py @@ -103,6 +103,7 @@ def validate_record_datatype(self, record): assert is_float( record.get("minimum_full_load_efficiency") ), f"minimum_full_load_efficiency requires to be numeric data type, instead got {record['minimum_full_load_efficiency']}" + return True def _preprocess_record(self, record): """ diff --git a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_heating.py b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_heating.py index 78f1e515f1..4d871f7ee4 100644 --- a/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_heating.py +++ b/data/openstudio_standards_data/database_tables/hvac_minimum_requirement_water_source_heat_pumps_heating.py @@ -90,6 +90,7 @@ def validate_record_datatype(self, record): assert is_float( record.get(f) ), f"{f} requires to be numeric data type, instead got {record[f]}" + return True def _preprocess_record(self, record): """ diff --git a/data/openstudio_standards_data/database_tables/level_2_electric_equipment.py b/data/openstudio_standards_data/database_tables/level_2_electric_equipment.py index 3faa52b8ae..f578448149 100644 --- a/data/openstudio_standards_data/database_tables/level_2_electric_equipment.py +++ b/data/openstudio_standards_data/database_tables/level_2_electric_equipment.py @@ -73,6 +73,7 @@ def validate_record_datatype(self, record): assert is_float( record.get(f) ), f"{f} requires to be numeric data type, instead got {record[f]}" + return True def _preprocess_record(self, record): """ diff --git a/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py b/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py index 53a5346833..78fa14bc03 100644 --- a/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py +++ b/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py @@ -51,9 +51,9 @@ def get_record_info(self): return RECORD_HELP def _get_weak_foreign_key_value(self, record): - associate_table = (getattr_either("level_3_lighting_definition_table", record),) + associate_table = getattr_either("level_3_lighting_definition_table", record) key = "id" - value = (getattr_either("level_3_lighting_definition_id", record),) + value = getattr_either("level_3_lighting_definition_id", record) return associate_table, key, value def _preprocess_record(self, record): diff --git a/data/openstudio_standards_data/database_tables/level_2_ventilation_space_types.py b/data/openstudio_standards_data/database_tables/level_2_ventilation_space_types.py index 4494a1b41a..f029fee36b 100644 --- a/data/openstudio_standards_data/database_tables/level_2_ventilation_space_types.py +++ b/data/openstudio_standards_data/database_tables/level_2_ventilation_space_types.py @@ -17,7 +17,6 @@ level_3_ventilation_definition_table TEXT NOT NULL, level_3_ventilation_definition_id INTEGER NOT NULL, FOREIGN KEY(ventilation_space_type_name) REFERENCES support_ventilation_space_type_name_tags(ventilation_space_type_name) - ); """ @@ -52,11 +51,9 @@ def get_record_info(self): return RECORD_HELP def _get_weak_foreign_key_value(self, record): - associate_table = ( - getattr_either("level_3_ventilation_definition_table", record), - ) + associate_table = getattr_either("level_3_ventilation_definition_table", record) key = "id" - value = (getattr_either("level_3_ventilation_definition_id", record),) + value = getattr_either("level_3_ventilation_definition_id", record) return associate_table, key, value def _preprocess_record(self, record): diff --git a/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_definition.py b/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_definition.py index 9d28051f33..7b7456c932 100644 --- a/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_definition.py +++ b/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_definition.py @@ -68,6 +68,7 @@ def validate_record_datatype(self, record): assert is_float( record.get("lighting_per_area") ), f"lighting_per_area requires to be numeric data type, instead got {record['lighting_per_area']}" + return True def _preprocess_record(self, record): """ diff --git a/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_definition.py b/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_definition.py index ece0e31df3..27db291329 100644 --- a/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_definition.py +++ b/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_definition.py @@ -85,6 +85,7 @@ def validate_record_datatype(self, record): assert is_float( record.get(f) ), f"{f} requires to be numeric data type, instead got {record[f]}" + return True def _preprocess_record(self, record): """ diff --git a/data/openstudio_standards_data/database_tables/support_constructions.py b/data/openstudio_standards_data/database_tables/support_constructions.py index 64883e21b3..ec8bb8a0cb 100644 --- a/data/openstudio_standards_data/database_tables/support_constructions.py +++ b/data/openstudio_standards_data/database_tables/support_constructions.py @@ -109,6 +109,7 @@ def validate_record_datatype(self, record): assert isinstance( record[f], str ), f"{f} requires to be a string, instead got {record[f]}" + return True def _preprocess_record(self, record): """ diff --git a/data/openstudio_standards_data/database_tables/support_materials.py b/data/openstudio_standards_data/database_tables/support_materials.py index 763cc1731f..e3faab5aa1 100644 --- a/data/openstudio_standards_data/database_tables/support_materials.py +++ b/data/openstudio_standards_data/database_tables/support_materials.py @@ -202,6 +202,7 @@ def validate_record_datatype(self, record): assert is_float( record.get(f) ), f"{f} requires to be numeric data type, instead got {record[f]}" + return True def _preprocess_record(self, record): """ diff --git a/data/openstudio_standards_data/database_tables/support_performance_curves.py b/data/openstudio_standards_data/database_tables/support_performance_curves.py index 9f5ddb64bf..0529d7e953 100644 --- a/data/openstudio_standards_data/database_tables/support_performance_curves.py +++ b/data/openstudio_standards_data/database_tables/support_performance_curves.py @@ -173,6 +173,7 @@ def validate_record_datatype(self, record): assert is_float( record.get(coeff) ), f"{coeff} requires to be numeric data type, instead got {record_id}" + return True def _preprocess_record(self, record): """ diff --git a/data/openstudio_standards_data/database_tables/system_requirement_economizer.py b/data/openstudio_standards_data/database_tables/system_requirement_economizer.py index 51b8602cc5..6c57b9c345 100644 --- a/data/openstudio_standards_data/database_tables/system_requirement_economizer.py +++ b/data/openstudio_standards_data/database_tables/system_requirement_economizer.py @@ -87,6 +87,7 @@ def validate_record_datatype(self, record): assert is_float( record.get(f) ), f"{f} requires to be numeric data type, instead got {record[f]}" + return True def _preprocess_record(self, record): """ diff --git a/data/openstudio_standards_data/database_tables/system_requirement_energy_recovery.py b/data/openstudio_standards_data/database_tables/system_requirement_energy_recovery.py index 44a3fc9e4c..14192c9825 100644 --- a/data/openstudio_standards_data/database_tables/system_requirement_energy_recovery.py +++ b/data/openstudio_standards_data/database_tables/system_requirement_energy_recovery.py @@ -136,6 +136,7 @@ def validate_record_datatype(self, record): assert is_float( record.get(f) ), f"{f} requires to be numeric data type, instead got {record[f]}" + return True def _preprocess_record(self, record): """ From 872f1d4b49fb7d36011f77b7b2e0f87f8d1c2ea7 Mon Sep 17 00:00:00 2001 From: Weili Xu Date: Tue, 28 Mar 2023 13:17:05 -0700 Subject: [PATCH 15/45] update error in the data file --- .../level_2_ventilation_space_types.csv | 346 +++++++++--------- .../level_2_ventilation_space_types.json | 346 +++++++++--------- 2 files changed, 346 insertions(+), 346 deletions(-) diff --git a/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.csv b/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.csv index 910270163c..85d239f91e 100644 --- a/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.csv +++ b/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.csv @@ -1,174 +1,174 @@ ventilation_space_type_name,level_3_ventilation_definition_table,level_3_ventilation_definition_id -correctional_facilities_cell,level_3_ventilation_90_1_2019,13 -correctional_facilities_dayroom,level_3_ventilation_90_1_2019,14 -correctional_facilities_guard_stations,level_3_ventilation_90_1_2019,15 -correctional_facilities_booking_waiting,level_3_ventilation_90_1_2019,12 -educational_facilities_daycare,level_3_ventilation_90_1_2019,21 -educational_facilities_classroom_young,level_3_ventilation_90_1_2019,17 -educational_facilities_classroom_old,level_3_ventilation_90_1_2019,18 -educational_facilities_lecture_classroom,level_3_ventilation_90_1_2019,22 -educational_facilities_lecture_hall,level_3_ventilation_90_1_2019,23 -educational_facilities_art_classroom,level_3_ventilation_90_1_2019,16 -educational_facilities_science_laboratories,level_3_ventilation_90_1_2019,28 -educational_facilities_wood_metal_shop,level_3_ventilation_90_1_2019,30 -educational_facilities_computer_lab,level_3_ventilation_90_1_2019,19 -educational_facilities_media_center,level_3_ventilation_90_1_2019,25 -educational_facilities_music_theater_dance,level_3_ventilation_90_1_2019,27 -educational_facilities_multiuse_assembly,level_3_ventilation_90_1_2019,26 -educational_facilities_daycare_sickroom,level_3_ventilation_90_1_2019,20 -educational_facilities_libraries,level_3_ventilation_90_1_2019,24 -educational_facilities_university_college_laboratories,level_3_ventilation_90_1_2019,29 -food_beverage_service_restaurant_dining_rooms,level_3_ventilation_90_1_2019,34 -food_beverage_service_cafeteria_fast_food_dining,level_3_ventilation_90_1_2019,32 -food_beverage_service_bars_cocktail_lounges,level_3_ventilation_90_1_2019,31 -food_beverage_service_kitchen,level_3_ventilation_90_1_2019,33 -general_conference_meeting,level_3_ventilation_90_1_2019,37 -general_conference_corridors,level_3_ventilation_90_1_2019,38 -general_conference_storage_rooms,level_3_ventilation_90_1_2019,39 -general_break_rooms,level_3_ventilation_90_1_2019,35 -general_coffee_stations,level_3_ventilation_90_1_2019,36 -hotels_motels_resorts_dormitories_bedroom_living_room,level_3_ventilation_90_1_2019,41 -hotels_motels_resorts_dormitories_barracks_sleeping_areas,level_3_ventilation_90_1_2019,40 -hotels_motels_resorts_dormitories_lobbies_prefunction,level_3_ventilation_90_1_2019,44 -hotels_motels_resorts_dormitories_multi_purpose_assembly,level_3_ventilation_90_1_2019,45 -hotels_motels_resorts_dormitories_laundry_rooms,level_3_ventilation_90_1_2019,42 -hotels_motels_resorts_dormitories_laundry_rooms_w_dwelling_units,level_3_ventilation_90_1_2019,43 -office_buildings_office_space,level_3_ventilation_90_1_2019,62 -office_buildings_reception_areas,level_3_ventilation_90_1_2019,63 -office_buildings_telephone_data_entry,level_3_ventilation_90_1_2019,64 -office_buildings_main_entry_lobbies,level_3_ventilation_90_1_2019,60 -office_buildings_breakrooms,level_3_ventilation_90_1_2019,59 -office_buildings_occupiable_storage_rooms,level_3_ventilation_90_1_2019,61 -miscellaneous_spaces_bank_ vaults_safe_deposit,level_3_ventilation_90_1_2019,47 -miscellaneous_spaces_computer,level_3_ventilation_90_1_2019,48 -miscellaneous_spaces_pharmacy,level_3_ventilation_90_1_2019,52 -miscellaneous_spaces_photo_studios,level_3_ventilation_90_1_2019,53 -miscellaneous_spaces_shipping_receiving,level_3_ventilation_90_1_2019,54 -miscellaneous_spaces_transportation_waiting,level_3_ventilation_90_1_2019,57 -miscellaneous_spaces_warehouses,level_3_ventilation_90_1_2019,58 -miscellaneous_spaces_banks_bank_lobbies,level_3_ventilation_90_1_2019,46 -miscellaneous_spaces_freezer_refrigerated_spaces,level_3_ventilation_90_1_2019,49 -miscellaneous_spaces_manufacturing_wo_hazardous_materials,level_3_ventilation_90_1_2019,50 -miscellaneous_spaces_manufacturing_w_hazardous_materials,level_3_ventilation_90_1_2019,51 -miscellaneous_spaces_sorting_packing_light_assembly,level_3_ventilation_90_1_2019,55 -miscellaneous_spaces_telephone_closets,level_3_ventilation_90_1_2019,56 -public_assembly_spaces_auditorium_seating_area,level_3_ventilation_90_1_2019,83 -public_assembly_spaces_religious_workshop,level_3_ventilation_90_1_2019,90 -public_assembly_spaces_courtrooms,level_3_ventilation_90_1_2019,84 -public_assembly_spaces_legislative_chambers,level_3_ventilation_90_1_2019,85 -public_assembly_spaces_libraries,level_3_ventilation_90_1_2019,86 -public_assembly_spaces_lobbies,level_3_ventilation_90_1_2019,87 -public_assembly_spaces_children_museums,level_3_ventilation_90_1_2019,88 -public_assembly_spaces_museums_galleries,level_3_ventilation_90_1_2019,89 -retail_sales,level_3_ventilation_90_1_2019,91 -retail_mall_common_areas,level_3_ventilation_90_1_2019,95 -retail_barbershop,level_3_ventilation_90_1_2019,92 -retail_beauty_nail_salons,level_3_ventilation_90_1_2019,93 -retail_pet_shops,level_3_ventilation_90_1_2019,96 -retail_supermarket,level_3_ventilation_90_1_2019,97 -retail_coin_operated_laundries,level_3_ventilation_90_1_2019,94 -sports_entertainment_sports_arena,level_3_ventilation_90_1_2019,102 -sports_entertainment_gym_stadium,level_3_ventilation_90_1_2019,102 -sports_entertainment_spectator_areas,level_3_ventilation_90_1_2019,105 -sports_entertainment_swimming,level_3_ventilation_90_1_2019,107 -sports_entertainment_disco_dance_floors,level_3_ventilation_90_1_2019,99 -sports_entertainment_health_club_aerobics_room,level_3_ventilation_90_1_2019,103 -sports_entertainment_health_club_weight_rooms,level_3_ventilation_90_1_2019,104 -sports_entertainment_bowling_alley,level_3_ventilation_90_1_2019,98 -sports_entertainment_gambling_casinos,level_3_ventilation_90_1_2019,100 -sports_entertainment_game_arcades,level_3_ventilation_90_1_2019,101 -sports_entertainment_stages_studios,level_3_ventilation_90_1_2019,106 -animal_facilities_animal_exam_room,level_3_ventilation_90_1_2019,1 -animal_facilities_animal_imaging,level_3_ventilation_90_1_2019,2 -animal_facilities_animal_operating_rooms,level_3_ventilation_90_1_2019,3 -animal_facilities_animal_postoperative_recovery_room,level_3_ventilation_90_1_2019,4 -animal_facilities_animal_preparation_rooms,level_3_ventilation_90_1_2019,5 -animal_facilities_animal_procedure_room,level_3_ventilation_90_1_2019,6 -animal_facilities_animal_surgery_scrub,level_3_ventilation_90_1_2019,7 -animal_facilities_large_animal_holding_room,level_3_ventilation_90_1_2019,8 -animal_facilities_necropsy,level_3_ventilation_90_1_2019,9 -animal_facilities_small_animal_cage_room_static,level_3_ventilation_90_1_2019,10 -animal_facilities_small_animal_cage_room_ventilated,level_3_ventilation_90_1_2019,11 -outpatient_health_care_facilities_birthing_room,level_3_ventilation_90_1_2019,65 -outpatient_health_care_facilities_class_1_imaging_rooms,level_3_ventilation_90_1_2019,66 -outpatient_health_care_facilities_dental_operatory,level_3_ventilation_90_1_2019,67 -outpatient_health_care_facilities_general_examination_room,level_3_ventilation_90_1_2019,68 -outpatient_health_care_facilities_other_dental_treatment_areas,level_3_ventilation_90_1_2019,69 -outpatient_health_care_facilities_physical_therapy_exercise_area,level_3_ventilation_90_1_2019,70 -outpatient_health_care_facilities_physical_therapy_individual_room,level_3_ventilation_90_1_2019,71 -outpatient_health_care_facilities_physical_therapeutic_pool_area,level_3_ventilation_90_1_2019,72 -outpatient_health_care_facilities_prosthetics_orthotics_room,level_3_ventilation_90_1_2019,73 -outpatient_health_care_facilities_psychiatric_consultation_room,level_3_ventilation_90_1_2019,74 -outpatient_health_care_facilities_psychiatric_examination_room,level_3_ventilation_90_1_2019,75 -outpatient_health_care_facilities_psychiatric_group_room,level_3_ventilation_90_1_2019,76 -outpatient_health_care_facilities_psychiatric_seclusion_room,level_3_ventilation_90_1_2019,77 -outpatient_health_care_facilities_speech_therapy_room,level_3_ventilation_90_1_2019,78 -outpatient_health_care_facilities_urgent_care_examination_room,level_3_ventilation_90_1_2019,79 -outpatient_health_care_facilities_urgent_care_observation_room,level_3_ventilation_90_1_2019,80 -outpatient_health_care_facilities_urgent_care_treatment_room,level_3_ventilation_90_1_2019,81 -outpatient_health_care_facilities_urgent_care_triage_room,level_3_ventilation_90_1_2019,82 -transient_residential_common_corridors,level_3_ventilation_90_1_2019,108 -transient_residential_dwelling_unit,level_3_ventilation_90_1_2019,109 -correctional_facilities_cell,level_3_ventilation_90_1_2004,1 -correctional_facilities_dayroom,level_3_ventilation_90_1_2004,2 -correctional_facilities_guard_stations,level_3_ventilation_90_1_2004,3 -correctional_facilities_booking_waiting,level_3_ventilation_90_1_2004,4 -educational_facilities_daycare,level_3_ventilation_90_1_2004,5 -educational_facilities_classroom_young,level_3_ventilation_90_1_2004,6 -educational_facilities_classroom_old,level_3_ventilation_90_1_2004,7 -educational_facilities_lecture_classroom,level_3_ventilation_90_1_2004,8 -educational_facilities_lecture_hall,level_3_ventilation_90_1_2004,9 -educational_facilities_art_classroom,level_3_ventilation_90_1_2004,10 -educational_facilities_science_laboratories,level_3_ventilation_90_1_2004,11 -educational_facilities_wood_metal_shop,level_3_ventilation_90_1_2004,12 -educational_facilities_computer_lab,level_3_ventilation_90_1_2004,13 -educational_facilities_media_center,level_3_ventilation_90_1_2004,14 -educational_facilities_music_theater_dance,level_3_ventilation_90_1_2004,15 -educational_facilities_multiuse_assembly,level_3_ventilation_90_1_2004,16 -food_beverage_service_restaurant_dining_rooms,level_3_ventilation_90_1_2004,17 -food_beverage_service_cafeteria_fast_food_dining,level_3_ventilation_90_1_2004,18 -food_beverage_service_bars_cocktail_lounges,level_3_ventilation_90_1_2004,19 -general_conference_meeting,level_3_ventilation_90_1_2004,20 -general_conference_corridors,level_3_ventilation_90_1_2004,21 -general_conference_storage_rooms,level_3_ventilation_90_1_2004,22 -hotels_motels_resorts_dormitories_bedroom_living_room,level_3_ventilation_90_1_2004,23 -hotels_motels_resorts_dormitories_barracks_sleeping_areas,level_3_ventilation_90_1_2004,24 -hotels_motels_resorts_dormitories_lobbies_prefunction,level_3_ventilation_90_1_2004,25 -hotels_motels_resorts_dormitories_multi_purpose_assembly,level_3_ventilation_90_1_2004,26 -office_buildings_office_space,level_3_ventilation_90_1_2004,27 -office_buildings_reception_areas,level_3_ventilation_90_1_2004,28 -office_buildings_telephone_data_entry,level_3_ventilation_90_1_2004,29 -office_buildings_main_entry_lobbies,level_3_ventilation_90_1_2004,30 -miscellaneous_spaces_bank_ vaults_safe_deposit,level_3_ventilation_90_1_2004,31 -miscellaneous_spaces_computer,level_3_ventilation_90_1_2004,32 -miscellaneous_spaces_pharmacy,level_3_ventilation_90_1_2004,33 -miscellaneous_spaces_photo_studios,level_3_ventilation_90_1_2004,34 -miscellaneous_spaces_shipping_receiving,level_3_ventilation_90_1_2004,35 -miscellaneous_spaces_transportation_waiting,level_3_ventilation_90_1_2004,36 -miscellaneous_spaces_warehouses,level_3_ventilation_90_1_2004,37 -public_assembly_spaces_auditorium_seating_area,level_3_ventilation_90_1_2004,38 -public_assembly_spaces_religious_workshop,level_3_ventilation_90_1_2004,39 -public_assembly_spaces_courtrooms,level_3_ventilation_90_1_2004,40 -public_assembly_spaces_legislative_chambers,level_3_ventilation_90_1_2004,41 -public_assembly_spaces_libraries,level_3_ventilation_90_1_2004,42 -public_assembly_spaces_lobbies,level_3_ventilation_90_1_2004,43 -public_assembly_spaces_children_museums,level_3_ventilation_90_1_2004,44 -public_assembly_spaces_museums_galleries,level_3_ventilation_90_1_2004,45 -retail_sales,level_3_ventilation_90_1_2004,46 -retail_mall_common_areas,level_3_ventilation_90_1_2004,47 -retail_barbershop,level_3_ventilation_90_1_2004,48 -retail_beauty_nail_salons,level_3_ventilation_90_1_2004,49 -retail_pet_shops,level_3_ventilation_90_1_2004,50 -retail_supermarket,level_3_ventilation_90_1_2004,51 -retail_coin_operated_laundries,level_3_ventilation_90_1_2004,52 -sports_entertainment_sports_arena,level_3_ventilation_90_1_2004,53 -sports_entertainment_gym_stadium,level_3_ventilation_90_1_2004,54 -sports_entertainment_spectator_areas,level_3_ventilation_90_1_2004,55 -sports_entertainment_swimming,level_3_ventilation_90_1_2004,56 -sports_entertainment_disco_dance_floors,level_3_ventilation_90_1_2004,57 -sports_entertainment_health_club_aerobics_room,level_3_ventilation_90_1_2004,58 -sports_entertainment_health_club_weight_rooms,level_3_ventilation_90_1_2004,59 -sports_entertainment_bowling_alley,level_3_ventilation_90_1_2004,60 -sports_entertainment_gambling_casinos,level_3_ventilation_90_1_2004,61 -sports_entertainment_game_arcades,level_3_ventilation_90_1_2004,62 -sports_entertainment_stages_studios,level_3_ventilation_90_1_2004,63 +correctional_facilities_cell,level_3_ventilation_62_1_2019,13 +correctional_facilities_dayroom,level_3_ventilation_62_1_2019,14 +correctional_facilities_guard_stations,level_3_ventilation_62_1_2019,15 +correctional_facilities_booking_waiting,level_3_ventilation_62_1_2019,12 +educational_facilities_daycare,level_3_ventilation_62_1_2019,21 +educational_facilities_classroom_young,level_3_ventilation_62_1_2019,17 +educational_facilities_classroom_old,level_3_ventilation_62_1_2019,18 +educational_facilities_lecture_classroom,level_3_ventilation_62_1_2019,22 +educational_facilities_lecture_hall,level_3_ventilation_62_1_2019,23 +educational_facilities_art_classroom,level_3_ventilation_62_1_2019,16 +educational_facilities_science_laboratories,level_3_ventilation_62_1_2019,28 +educational_facilities_wood_metal_shop,level_3_ventilation_62_1_2019,30 +educational_facilities_computer_lab,level_3_ventilation_62_1_2019,19 +educational_facilities_media_center,level_3_ventilation_62_1_2019,25 +educational_facilities_music_theater_dance,level_3_ventilation_62_1_2019,27 +educational_facilities_multiuse_assembly,level_3_ventilation_62_1_2019,26 +educational_facilities_daycare_sickroom,level_3_ventilation_62_1_2019,20 +educational_facilities_libraries,level_3_ventilation_62_1_2019,24 +educational_facilities_university_college_laboratories,level_3_ventilation_62_1_2019,29 +food_beverage_service_restaurant_dining_rooms,level_3_ventilation_62_1_2019,34 +food_beverage_service_cafeteria_fast_food_dining,level_3_ventilation_62_1_2019,32 +food_beverage_service_bars_cocktail_lounges,level_3_ventilation_62_1_2019,31 +food_beverage_service_kitchen,level_3_ventilation_62_1_2019,33 +general_conference_meeting,level_3_ventilation_62_1_2019,37 +general_conference_corridors,level_3_ventilation_62_1_2019,38 +general_conference_storage_rooms,level_3_ventilation_62_1_2019,39 +general_break_rooms,level_3_ventilation_62_1_2019,35 +general_coffee_stations,level_3_ventilation_62_1_2019,36 +hotels_motels_resorts_dormitories_bedroom_living_room,level_3_ventilation_62_1_2019,41 +hotels_motels_resorts_dormitories_barracks_sleeping_areas,level_3_ventilation_62_1_2019,40 +hotels_motels_resorts_dormitories_lobbies_prefunction,level_3_ventilation_62_1_2019,44 +hotels_motels_resorts_dormitories_multi_purpose_assembly,level_3_ventilation_62_1_2019,45 +hotels_motels_resorts_dormitories_laundry_rooms,level_3_ventilation_62_1_2019,42 +hotels_motels_resorts_dormitories_laundry_rooms_w_dwelling_units,level_3_ventilation_62_1_2019,43 +office_buildings_office_space,level_3_ventilation_62_1_2019,62 +office_buildings_reception_areas,level_3_ventilation_62_1_2019,63 +office_buildings_telephone_data_entry,level_3_ventilation_62_1_2019,64 +office_buildings_main_entry_lobbies,level_3_ventilation_62_1_2019,60 +office_buildings_breakrooms,level_3_ventilation_62_1_2019,59 +office_buildings_occupiable_storage_rooms,level_3_ventilation_62_1_2019,61 +miscellaneous_spaces_bank_ vaults_safe_deposit,level_3_ventilation_62_1_2019,47 +miscellaneous_spaces_computer,level_3_ventilation_62_1_2019,48 +miscellaneous_spaces_pharmacy,level_3_ventilation_62_1_2019,52 +miscellaneous_spaces_photo_studios,level_3_ventilation_62_1_2019,53 +miscellaneous_spaces_shipping_receiving,level_3_ventilation_62_1_2019,54 +miscellaneous_spaces_transportation_waiting,level_3_ventilation_62_1_2019,57 +miscellaneous_spaces_warehouses,level_3_ventilation_62_1_2019,58 +miscellaneous_spaces_banks_bank_lobbies,level_3_ventilation_62_1_2019,46 +miscellaneous_spaces_freezer_refrigerated_spaces,level_3_ventilation_62_1_2019,49 +miscellaneous_spaces_manufacturing_wo_hazardous_materials,level_3_ventilation_62_1_2019,50 +miscellaneous_spaces_manufacturing_w_hazardous_materials,level_3_ventilation_62_1_2019,51 +miscellaneous_spaces_sorting_packing_light_assembly,level_3_ventilation_62_1_2019,55 +miscellaneous_spaces_telephone_closets,level_3_ventilation_62_1_2019,56 +public_assembly_spaces_auditorium_seating_area,level_3_ventilation_62_1_2019,83 +public_assembly_spaces_religious_workshop,level_3_ventilation_62_1_2019,90 +public_assembly_spaces_courtrooms,level_3_ventilation_62_1_2019,84 +public_assembly_spaces_legislative_chambers,level_3_ventilation_62_1_2019,85 +public_assembly_spaces_libraries,level_3_ventilation_62_1_2019,86 +public_assembly_spaces_lobbies,level_3_ventilation_62_1_2019,87 +public_assembly_spaces_children_museums,level_3_ventilation_62_1_2019,88 +public_assembly_spaces_museums_galleries,level_3_ventilation_62_1_2019,89 +retail_sales,level_3_ventilation_62_1_2019,91 +retail_mall_common_areas,level_3_ventilation_62_1_2019,95 +retail_barbershop,level_3_ventilation_62_1_2019,92 +retail_beauty_nail_salons,level_3_ventilation_62_1_2019,93 +retail_pet_shops,level_3_ventilation_62_1_2019,96 +retail_supermarket,level_3_ventilation_62_1_2019,97 +retail_coin_operated_laundries,level_3_ventilation_62_1_2019,94 +sports_entertainment_sports_arena,level_3_ventilation_62_1_2019,102 +sports_entertainment_gym_stadium,level_3_ventilation_62_1_2019,102 +sports_entertainment_spectator_areas,level_3_ventilation_62_1_2019,105 +sports_entertainment_swimming,level_3_ventilation_62_1_2019,107 +sports_entertainment_disco_dance_floors,level_3_ventilation_62_1_2019,99 +sports_entertainment_health_club_aerobics_room,level_3_ventilation_62_1_2019,103 +sports_entertainment_health_club_weight_rooms,level_3_ventilation_62_1_2019,104 +sports_entertainment_bowling_alley,level_3_ventilation_62_1_2019,98 +sports_entertainment_gambling_casinos,level_3_ventilation_62_1_2019,100 +sports_entertainment_game_arcades,level_3_ventilation_62_1_2019,101 +sports_entertainment_stages_studios,level_3_ventilation_62_1_2019,106 +animal_facilities_animal_exam_room,level_3_ventilation_62_1_2019,1 +animal_facilities_animal_imaging,level_3_ventilation_62_1_2019,2 +animal_facilities_animal_operating_rooms,level_3_ventilation_62_1_2019,3 +animal_facilities_animal_postoperative_recovery_room,level_3_ventilation_62_1_2019,4 +animal_facilities_animal_preparation_rooms,level_3_ventilation_62_1_2019,5 +animal_facilities_animal_procedure_room,level_3_ventilation_62_1_2019,6 +animal_facilities_animal_surgery_scrub,level_3_ventilation_62_1_2019,7 +animal_facilities_large_animal_holding_room,level_3_ventilation_62_1_2019,8 +animal_facilities_necropsy,level_3_ventilation_62_1_2019,9 +animal_facilities_small_animal_cage_room_static,level_3_ventilation_62_1_2019,10 +animal_facilities_small_animal_cage_room_ventilated,level_3_ventilation_62_1_2019,11 +outpatient_health_care_facilities_birthing_room,level_3_ventilation_62_1_2019,65 +outpatient_health_care_facilities_class_1_imaging_rooms,level_3_ventilation_62_1_2019,66 +outpatient_health_care_facilities_dental_operatory,level_3_ventilation_62_1_2019,67 +outpatient_health_care_facilities_general_examination_room,level_3_ventilation_62_1_2019,68 +outpatient_health_care_facilities_other_dental_treatment_areas,level_3_ventilation_62_1_2019,69 +outpatient_health_care_facilities_physical_therapy_exercise_area,level_3_ventilation_62_1_2019,70 +outpatient_health_care_facilities_physical_therapy_individual_room,level_3_ventilation_62_1_2019,71 +outpatient_health_care_facilities_physical_therapeutic_pool_area,level_3_ventilation_62_1_2019,72 +outpatient_health_care_facilities_prosthetics_orthotics_room,level_3_ventilation_62_1_2019,73 +outpatient_health_care_facilities_psychiatric_consultation_room,level_3_ventilation_62_1_2019,74 +outpatient_health_care_facilities_psychiatric_examination_room,level_3_ventilation_62_1_2019,75 +outpatient_health_care_facilities_psychiatric_group_room,level_3_ventilation_62_1_2019,76 +outpatient_health_care_facilities_psychiatric_seclusion_room,level_3_ventilation_62_1_2019,77 +outpatient_health_care_facilities_speech_therapy_room,level_3_ventilation_62_1_2019,78 +outpatient_health_care_facilities_urgent_care_examination_room,level_3_ventilation_62_1_2019,79 +outpatient_health_care_facilities_urgent_care_observation_room,level_3_ventilation_62_1_2019,80 +outpatient_health_care_facilities_urgent_care_treatment_room,level_3_ventilation_62_1_2019,81 +outpatient_health_care_facilities_urgent_care_triage_room,level_3_ventilation_62_1_2019,82 +transient_residential_common_corridors,level_3_ventilation_62_1_2019,108 +transient_residential_dwelling_unit,level_3_ventilation_62_1_2019,109 +correctional_facilities_cell,level_3_ventilation_62_1_2004,1 +correctional_facilities_dayroom,level_3_ventilation_62_1_2004,2 +correctional_facilities_guard_stations,level_3_ventilation_62_1_2004,3 +correctional_facilities_booking_waiting,level_3_ventilation_62_1_2004,4 +educational_facilities_daycare,level_3_ventilation_62_1_2004,5 +educational_facilities_classroom_young,level_3_ventilation_62_1_2004,6 +educational_facilities_classroom_old,level_3_ventilation_62_1_2004,7 +educational_facilities_lecture_classroom,level_3_ventilation_62_1_2004,8 +educational_facilities_lecture_hall,level_3_ventilation_62_1_2004,9 +educational_facilities_art_classroom,level_3_ventilation_62_1_2004,10 +educational_facilities_science_laboratories,level_3_ventilation_62_1_2004,11 +educational_facilities_wood_metal_shop,level_3_ventilation_62_1_2004,12 +educational_facilities_computer_lab,level_3_ventilation_62_1_2004,13 +educational_facilities_media_center,level_3_ventilation_62_1_2004,14 +educational_facilities_music_theater_dance,level_3_ventilation_62_1_2004,15 +educational_facilities_multiuse_assembly,level_3_ventilation_62_1_2004,16 +food_beverage_service_restaurant_dining_rooms,level_3_ventilation_62_1_2004,17 +food_beverage_service_cafeteria_fast_food_dining,level_3_ventilation_62_1_2004,18 +food_beverage_service_bars_cocktail_lounges,level_3_ventilation_62_1_2004,19 +general_conference_meeting,level_3_ventilation_62_1_2004,20 +general_conference_corridors,level_3_ventilation_62_1_2004,21 +general_conference_storage_rooms,level_3_ventilation_62_1_2004,22 +hotels_motels_resorts_dormitories_bedroom_living_room,level_3_ventilation_62_1_2004,23 +hotels_motels_resorts_dormitories_barracks_sleeping_areas,level_3_ventilation_62_1_2004,24 +hotels_motels_resorts_dormitories_lobbies_prefunction,level_3_ventilation_62_1_2004,25 +hotels_motels_resorts_dormitories_multi_purpose_assembly,level_3_ventilation_62_1_2004,26 +office_buildings_office_space,level_3_ventilation_62_1_2004,27 +office_buildings_reception_areas,level_3_ventilation_62_1_2004,28 +office_buildings_telephone_data_entry,level_3_ventilation_62_1_2004,29 +office_buildings_main_entry_lobbies,level_3_ventilation_62_1_2004,30 +miscellaneous_spaces_bank_ vaults_safe_deposit,level_3_ventilation_62_1_2004,31 +miscellaneous_spaces_computer,level_3_ventilation_62_1_2004,32 +miscellaneous_spaces_pharmacy,level_3_ventilation_62_1_2004,33 +miscellaneous_spaces_photo_studios,level_3_ventilation_62_1_2004,34 +miscellaneous_spaces_shipping_receiving,level_3_ventilation_62_1_2004,35 +miscellaneous_spaces_transportation_waiting,level_3_ventilation_62_1_2004,36 +miscellaneous_spaces_warehouses,level_3_ventilation_62_1_2004,37 +public_assembly_spaces_auditorium_seating_area,level_3_ventilation_62_1_2004,38 +public_assembly_spaces_religious_workshop,level_3_ventilation_62_1_2004,39 +public_assembly_spaces_courtrooms,level_3_ventilation_62_1_2004,40 +public_assembly_spaces_legislative_chambers,level_3_ventilation_62_1_2004,41 +public_assembly_spaces_libraries,level_3_ventilation_62_1_2004,42 +public_assembly_spaces_lobbies,level_3_ventilation_62_1_2004,43 +public_assembly_spaces_children_museums,level_3_ventilation_62_1_2004,44 +public_assembly_spaces_museums_galleries,level_3_ventilation_62_1_2004,45 +retail_sales,level_3_ventilation_62_1_2004,46 +retail_mall_common_areas,level_3_ventilation_62_1_2004,47 +retail_barbershop,level_3_ventilation_62_1_2004,48 +retail_beauty_nail_salons,level_3_ventilation_62_1_2004,49 +retail_pet_shops,level_3_ventilation_62_1_2004,50 +retail_supermarket,level_3_ventilation_62_1_2004,51 +retail_coin_operated_laundries,level_3_ventilation_62_1_2004,52 +sports_entertainment_sports_arena,level_3_ventilation_62_1_2004,53 +sports_entertainment_gym_stadium,level_3_ventilation_62_1_2004,54 +sports_entertainment_spectator_areas,level_3_ventilation_62_1_2004,55 +sports_entertainment_swimming,level_3_ventilation_62_1_2004,56 +sports_entertainment_disco_dance_floors,level_3_ventilation_62_1_2004,57 +sports_entertainment_health_club_aerobics_room,level_3_ventilation_62_1_2004,58 +sports_entertainment_health_club_weight_rooms,level_3_ventilation_62_1_2004,59 +sports_entertainment_bowling_alley,level_3_ventilation_62_1_2004,60 +sports_entertainment_gambling_casinos,level_3_ventilation_62_1_2004,61 +sports_entertainment_game_arcades,level_3_ventilation_62_1_2004,62 +sports_entertainment_stages_studios,level_3_ventilation_62_1_2004,63 diff --git a/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.json b/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.json index 7e51949c1a..689b70d05b 100644 --- a/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.json +++ b/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.json @@ -1,867 +1,867 @@ [ { "ventilation_space_type_name": "correctional_facilities_cell", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 13 }, { "ventilation_space_type_name": "correctional_facilities_dayroom", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 14 }, { "ventilation_space_type_name": "correctional_facilities_guard_stations", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 15 }, { "ventilation_space_type_name": "correctional_facilities_booking_waiting", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 12 }, { "ventilation_space_type_name": "educational_facilities_daycare", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 21 }, { "ventilation_space_type_name": "educational_facilities_classroom_young", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 17 }, { "ventilation_space_type_name": "educational_facilities_classroom_old", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 18 }, { "ventilation_space_type_name": "educational_facilities_lecture_classroom", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 22 }, { "ventilation_space_type_name": "educational_facilities_lecture_hall", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 23 }, { "ventilation_space_type_name": "educational_facilities_art_classroom", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 16 }, { "ventilation_space_type_name": "educational_facilities_science_laboratories", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 28 }, { "ventilation_space_type_name": "educational_facilities_wood_metal_shop", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 30 }, { "ventilation_space_type_name": "educational_facilities_computer_lab", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 19 }, { "ventilation_space_type_name": "educational_facilities_media_center", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 25 }, { "ventilation_space_type_name": "educational_facilities_music_theater_dance", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 27 }, { "ventilation_space_type_name": "educational_facilities_multiuse_assembly", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 26 }, { "ventilation_space_type_name": "educational_facilities_daycare_sickroom", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 20 }, { "ventilation_space_type_name": "educational_facilities_libraries", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 24 }, { "ventilation_space_type_name": "educational_facilities_university_college_laboratories", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 29 }, { "ventilation_space_type_name": "food_beverage_service_restaurant_dining_rooms", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 34 }, { "ventilation_space_type_name": "food_beverage_service_cafeteria_fast_food_dining", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 32 }, { "ventilation_space_type_name": "food_beverage_service_bars_cocktail_lounges", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 31 }, { "ventilation_space_type_name": "food_beverage_service_kitchen", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 33 }, { "ventilation_space_type_name": "general_conference_meeting", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 37 }, { "ventilation_space_type_name": "general_conference_corridors", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 38 }, { "ventilation_space_type_name": "general_conference_storage_rooms", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 39 }, { "ventilation_space_type_name": "general_break_rooms", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 35 }, { "ventilation_space_type_name": "general_coffee_stations", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 36 }, { "ventilation_space_type_name": "hotels_motels_resorts_dormitories_bedroom_living_room", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 41 }, { "ventilation_space_type_name": "hotels_motels_resorts_dormitories_barracks_sleeping_areas", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 40 }, { "ventilation_space_type_name": "hotels_motels_resorts_dormitories_lobbies_prefunction", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 44 }, { "ventilation_space_type_name": "hotels_motels_resorts_dormitories_multi_purpose_assembly", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 45 }, { "ventilation_space_type_name": "hotels_motels_resorts_dormitories_laundry_rooms", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 42 }, { "ventilation_space_type_name": "hotels_motels_resorts_dormitories_laundry_rooms_w_dwelling_units", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 43 }, { "ventilation_space_type_name": "office_buildings_office_space", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 62 }, { "ventilation_space_type_name": "office_buildings_reception_areas", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 63 }, { "ventilation_space_type_name": "office_buildings_telephone_data_entry", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 64 }, { "ventilation_space_type_name": "office_buildings_main_entry_lobbies", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 60 }, { "ventilation_space_type_name": "office_buildings_breakrooms", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 59 }, { "ventilation_space_type_name": "office_buildings_occupiable_storage_rooms", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 61 }, { "ventilation_space_type_name": "miscellaneous_spaces_bank_ vaults_safe_deposit", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 47 }, { "ventilation_space_type_name": "miscellaneous_spaces_computer", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 48 }, { "ventilation_space_type_name": "miscellaneous_spaces_pharmacy", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 52 }, { "ventilation_space_type_name": "miscellaneous_spaces_photo_studios", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 53 }, { "ventilation_space_type_name": "miscellaneous_spaces_shipping_receiving", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 54 }, { "ventilation_space_type_name": "miscellaneous_spaces_transportation_waiting", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 57 }, { "ventilation_space_type_name": "miscellaneous_spaces_warehouses", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 58 }, { "ventilation_space_type_name": "miscellaneous_spaces_banks_bank_lobbies", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 46 }, { "ventilation_space_type_name": "miscellaneous_spaces_freezer_refrigerated_spaces", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 49 }, { "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 50 }, { "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_w_hazardous_materials", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 51 }, { "ventilation_space_type_name": "miscellaneous_spaces_sorting_packing_light_assembly", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 55 }, { "ventilation_space_type_name": "miscellaneous_spaces_telephone_closets", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 56 }, { "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 83 }, { "ventilation_space_type_name": "public_assembly_spaces_religious_workshop", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 90 }, { "ventilation_space_type_name": "public_assembly_spaces_courtrooms", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 84 }, { "ventilation_space_type_name": "public_assembly_spaces_legislative_chambers", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 85 }, { "ventilation_space_type_name": "public_assembly_spaces_libraries", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 86 }, { "ventilation_space_type_name": "public_assembly_spaces_lobbies", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 87 }, { "ventilation_space_type_name": "public_assembly_spaces_children_museums", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 88 }, { "ventilation_space_type_name": "public_assembly_spaces_museums_galleries", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 89 }, { "ventilation_space_type_name": "retail_sales", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 91 }, { "ventilation_space_type_name": "retail_mall_common_areas", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 95 }, { "ventilation_space_type_name": "retail_barbershop", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 92 }, { "ventilation_space_type_name": "retail_beauty_nail_salons", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 93 }, { "ventilation_space_type_name": "retail_pet_shops", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 96 }, { "ventilation_space_type_name": "retail_supermarket", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 97 }, { "ventilation_space_type_name": "retail_coin_operated_laundries", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 94 }, { "ventilation_space_type_name": "sports_entertainment_sports_arena", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 102 }, { "ventilation_space_type_name": "sports_entertainment_gym_stadium", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 102 }, { "ventilation_space_type_name": "sports_entertainment_spectator_areas", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 105 }, { "ventilation_space_type_name": "sports_entertainment_swimming", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 107 }, { "ventilation_space_type_name": "sports_entertainment_disco_dance_floors", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 99 }, { "ventilation_space_type_name": "sports_entertainment_health_club_aerobics_room", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 103 }, { "ventilation_space_type_name": "sports_entertainment_health_club_weight_rooms", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 104 }, { "ventilation_space_type_name": "sports_entertainment_bowling_alley", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 98 }, { "ventilation_space_type_name": "sports_entertainment_gambling_casinos", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 100 }, { "ventilation_space_type_name": "sports_entertainment_game_arcades", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 101 }, { "ventilation_space_type_name": "sports_entertainment_stages_studios", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 106 }, { "ventilation_space_type_name": "animal_facilities_animal_exam_room", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 1 }, { "ventilation_space_type_name": "animal_facilities_animal_imaging", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 2 }, { "ventilation_space_type_name": "animal_facilities_animal_operating_rooms", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 3 }, { "ventilation_space_type_name": "animal_facilities_animal_postoperative_recovery_room", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 4 }, { "ventilation_space_type_name": "animal_facilities_animal_preparation_rooms", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 5 }, { "ventilation_space_type_name": "animal_facilities_animal_procedure_room", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 6 }, { "ventilation_space_type_name": "animal_facilities_animal_surgery_scrub", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 7 }, { "ventilation_space_type_name": "animal_facilities_large_animal_holding_room", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 8 }, { "ventilation_space_type_name": "animal_facilities_necropsy", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 9 }, { "ventilation_space_type_name": "animal_facilities_small_animal_cage_room_static", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 10 }, { "ventilation_space_type_name": "animal_facilities_small_animal_cage_room_ventilated", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 11 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_birthing_room", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 65 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_class_1_imaging_rooms", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 66 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_dental_operatory", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 67 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_general_examination_room", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 68 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_other_dental_treatment_areas", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 69 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_physical_therapy_exercise_area", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 70 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_physical_therapy_individual_room", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 71 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_physical_therapeutic_pool_area", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 72 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_prosthetics_orthotics_room", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 73 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_psychiatric_consultation_room", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 74 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_psychiatric_examination_room", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 75 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_psychiatric_group_room", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 76 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_psychiatric_seclusion_room", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 77 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_speech_therapy_room", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 78 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_urgent_care_examination_room", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 79 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_urgent_care_observation_room", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 80 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_urgent_care_treatment_room", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 81 }, { "ventilation_space_type_name": "outpatient_health_care_facilities_urgent_care_triage_room", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 82 }, { "ventilation_space_type_name": "transient_residential_common_corridors", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 108 }, { "ventilation_space_type_name": "transient_residential_dwelling_unit", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2019", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 109 }, { "ventilation_space_type_name": "correctional_facilities_cell", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 1 }, { "ventilation_space_type_name": "correctional_facilities_dayroom", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 2 }, { "ventilation_space_type_name": "correctional_facilities_guard_stations", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 3 }, { "ventilation_space_type_name": "correctional_facilities_booking_waiting", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 4 }, { "ventilation_space_type_name": "educational_facilities_daycare", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 5 }, { "ventilation_space_type_name": "educational_facilities_classroom_young", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 6 }, { "ventilation_space_type_name": "educational_facilities_classroom_old", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 7 }, { "ventilation_space_type_name": "educational_facilities_lecture_classroom", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 8 }, { "ventilation_space_type_name": "educational_facilities_lecture_hall", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 9 }, { "ventilation_space_type_name": "educational_facilities_art_classroom", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 10 }, { "ventilation_space_type_name": "educational_facilities_science_laboratories", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 11 }, { "ventilation_space_type_name": "educational_facilities_wood_metal_shop", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 12 }, { "ventilation_space_type_name": "educational_facilities_computer_lab", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 13 }, { "ventilation_space_type_name": "educational_facilities_media_center", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 14 }, { "ventilation_space_type_name": "educational_facilities_music_theater_dance", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 15 }, { "ventilation_space_type_name": "educational_facilities_multiuse_assembly", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 16 }, { "ventilation_space_type_name": "food_beverage_service_restaurant_dining_rooms", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 17 }, { "ventilation_space_type_name": "food_beverage_service_cafeteria_fast_food_dining", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 18 }, { "ventilation_space_type_name": "food_beverage_service_bars_cocktail_lounges", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 19 }, { "ventilation_space_type_name": "general_conference_meeting", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 20 }, { "ventilation_space_type_name": "general_conference_corridors", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 21 }, { "ventilation_space_type_name": "general_conference_storage_rooms", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 22 }, { "ventilation_space_type_name": "hotels_motels_resorts_dormitories_bedroom_living_room", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 23 }, { "ventilation_space_type_name": "hotels_motels_resorts_dormitories_barracks_sleeping_areas", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 24 }, { "ventilation_space_type_name": "hotels_motels_resorts_dormitories_lobbies_prefunction", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 25 }, { "ventilation_space_type_name": "hotels_motels_resorts_dormitories_multi_purpose_assembly", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 26 }, { "ventilation_space_type_name": "office_buildings_office_space", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 27 }, { "ventilation_space_type_name": "office_buildings_reception_areas", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 28 }, { "ventilation_space_type_name": "office_buildings_telephone_data_entry", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 29 }, { "ventilation_space_type_name": "office_buildings_main_entry_lobbies", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 30 }, { "ventilation_space_type_name": "miscellaneous_spaces_bank_ vaults_safe_deposit", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 31 }, { "ventilation_space_type_name": "miscellaneous_spaces_computer", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 32 }, { "ventilation_space_type_name": "miscellaneous_spaces_pharmacy", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 33 }, { "ventilation_space_type_name": "miscellaneous_spaces_photo_studios", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 34 }, { "ventilation_space_type_name": "miscellaneous_spaces_shipping_receiving", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 35 }, { "ventilation_space_type_name": "miscellaneous_spaces_transportation_waiting", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 36 }, { "ventilation_space_type_name": "miscellaneous_spaces_warehouses", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 37 }, { "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 38 }, { "ventilation_space_type_name": "public_assembly_spaces_religious_workshop", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 39 }, { "ventilation_space_type_name": "public_assembly_spaces_courtrooms", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 40 }, { "ventilation_space_type_name": "public_assembly_spaces_legislative_chambers", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 41 }, { "ventilation_space_type_name": "public_assembly_spaces_libraries", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 42 }, { "ventilation_space_type_name": "public_assembly_spaces_lobbies", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 43 }, { "ventilation_space_type_name": "public_assembly_spaces_children_museums", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 44 }, { "ventilation_space_type_name": "public_assembly_spaces_museums_galleries", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 45 }, { "ventilation_space_type_name": "retail_sales", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 46 }, { "ventilation_space_type_name": "retail_mall_common_areas", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 47 }, { "ventilation_space_type_name": "retail_barbershop", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 48 }, { "ventilation_space_type_name": "retail_beauty_nail_salons", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 49 }, { "ventilation_space_type_name": "retail_pet_shops", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 50 }, { "ventilation_space_type_name": "retail_supermarket", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 51 }, { "ventilation_space_type_name": "retail_coin_operated_laundries", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 52 }, { "ventilation_space_type_name": "sports_entertainment_sports_arena", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 53 }, { "ventilation_space_type_name": "sports_entertainment_gym_stadium", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 54 }, { "ventilation_space_type_name": "sports_entertainment_spectator_areas", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 55 }, { "ventilation_space_type_name": "sports_entertainment_swimming", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 56 }, { "ventilation_space_type_name": "sports_entertainment_disco_dance_floors", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 57 }, { "ventilation_space_type_name": "sports_entertainment_health_club_aerobics_room", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 58 }, { "ventilation_space_type_name": "sports_entertainment_health_club_weight_rooms", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 59 }, { "ventilation_space_type_name": "sports_entertainment_bowling_alley", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 60 }, { "ventilation_space_type_name": "sports_entertainment_gambling_casinos", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 61 }, { "ventilation_space_type_name": "sports_entertainment_game_arcades", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 62 }, { "ventilation_space_type_name": "sports_entertainment_stages_studios", - "level_3_ventilation_definition_table": "level_3_ventilation_90_1_2004", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 63 } ] \ No newline at end of file From 502a75ea71c370358193fa0bd4da0ff53eaa1423 Mon Sep 17 00:00:00 2001 From: Jeremy L <5149279+lymereJ@users.noreply.github.com> Date: Wed, 29 Mar 2023 16:02:19 -0700 Subject: [PATCH 16/45] Data refactoring space type data (#1480) * Merge latest changes from dev branch. * Update space type data. --- .../create_openstudio_standards_json.py | 6 +- .../applications/form/update_space_data.py | 24 +- data/openstudio_standards_data/client.py | 8 +- .../database_files/level_1_space_types.csv | 193 +- .../database_files/level_1_space_types.json | 996 +- .../level_2_electric_equipment.csv | 183 +- .../level_2_electric_equipment.json | 204 +- .../level_2_lighting_space_types.csv | 996 +- .../level_2_lighting_space_types.json | 5242 ++- .../level_2_natural_gas_equipment.csv | 7 + .../level_2_ventilation_space_types.csv | 698 +- .../level_2_ventilation_space_types.json | 2482 +- .../level_3_lighting_90_1_2004.csv | 253 +- .../level_3_lighting_90_1_2004.json | 1516 +- .../level_3_lighting_90_1_2007.csv | 130 + .../level_3_lighting_90_1_2007.json | 1808 + .../level_3_lighting_90_1_2010.csv | 134 + .../level_3_lighting_90_1_2010.json | 1864 ++ .../level_3_lighting_90_1_2013.csv | 144 + .../level_3_lighting_90_1_2013.json | 2004 ++ .../level_3_lighting_90_1_2016.csv | 143 + .../level_3_lighting_90_1_2016.json | 1990 ++ .../level_3_lighting_90_1_2019.csv | 279 +- .../level_3_lighting_90_1_2019.json | 1670 +- .../level_3_ventilation_62_1_1999.csv | 84 + .../level_3_ventilation_62_1_1999.json | 1081 + .../level_3_ventilation_62_1_2004.csv | 3 +- .../level_3_ventilation_62_1_2004.json | 517 +- .../level_3_ventilation_62_1_2007.csv | 76 + .../level_3_ventilation_62_1_2007.json | 977 + .../level_3_ventilation_62_1_2010.csv | 80 + .../level_3_ventilation_62_1_2010.json | 1029 + .../level_3_ventilation_62_1_2013.csv | 80 + .../level_3_ventilation_62_1_2013.json | 1029 + .../level_3_ventilation_62_1_2016.csv | 80 + .../level_3_ventilation_62_1_2016.json | 1029 + .../level_3_ventilation_62_1_2019.csv | 19 +- .../level_3_ventilation_62_1_2019.json | 901 +- ...lectric_equipment_space_type_name_tags.csv | 207 +- ...ectric_equipment_space_type_name_tags.json | 409 +- .../support_lighting_space_type_name_tags.csv | 276 +- ...support_lighting_space_type_name_tags.json | 356 +- .../support_lighting_technologies.csv | 2 + .../support_lighting_technologies.json | 18 + .../database_files/support_schedules.csv | 811 + .../database_files/support_schedules.json | 27542 ++++++++++++++++ ...pport_ventilation_space_type_name_tags.csv | 208 +- ...port_ventilation_space_type_name_tags.json | 232 +- .../database_tables/__init__.py | 13 +- .../database_tables/level_1_space_types.py | 25 +- .../level_2_lighting_space_types.py | 37 +- .../level_2_natural_gas_equipment.py | 91 + .../level_3_lighting_90_1_2007.py | 13 + .../level_3_lighting_90_1_2010.py | 13 + .../level_3_lighting_90_1_2013.py | 13 + .../level_3_lighting_90_1_2016.py | 13 + .../level_3_lighting_90_1_definition.py | 69 +- .../level_3_ventilation_62_1_1999.py | 13 + .../level_3_ventilation_62_1_2007.py | 13 + .../level_3_ventilation_62_1_2010.py | 13 + .../level_3_ventilation_62_1_2013.py | 13 + .../level_3_ventilation_62_1_2016.py | 13 + .../level_3_ventilation_62_1_definition.py | 52 +- .../support_lighting_technologies.py | 159 + .../database_tables/support_schedules.py | 261 + .../query/fetch/space.py | 4 +- 66 files changed, 55249 insertions(+), 5599 deletions(-) create mode 100644 data/openstudio_standards_data/database_files/level_2_natural_gas_equipment.csv create mode 100644 data/openstudio_standards_data/database_files/level_3_lighting_90_1_2007.csv create mode 100644 data/openstudio_standards_data/database_files/level_3_lighting_90_1_2007.json create mode 100644 data/openstudio_standards_data/database_files/level_3_lighting_90_1_2010.csv create mode 100644 data/openstudio_standards_data/database_files/level_3_lighting_90_1_2010.json create mode 100644 data/openstudio_standards_data/database_files/level_3_lighting_90_1_2013.csv create mode 100644 data/openstudio_standards_data/database_files/level_3_lighting_90_1_2013.json create mode 100644 data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.csv create mode 100644 data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.json create mode 100644 data/openstudio_standards_data/database_files/level_3_ventilation_62_1_1999.csv create mode 100644 data/openstudio_standards_data/database_files/level_3_ventilation_62_1_1999.json create mode 100644 data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2007.csv create mode 100644 data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2007.json create mode 100644 data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2010.csv create mode 100644 data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2010.json create mode 100644 data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2013.csv create mode 100644 data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2013.json create mode 100644 data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2016.csv create mode 100644 data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2016.json create mode 100644 data/openstudio_standards_data/database_files/support_lighting_technologies.csv create mode 100644 data/openstudio_standards_data/database_files/support_lighting_technologies.json create mode 100644 data/openstudio_standards_data/database_files/support_schedules.csv create mode 100644 data/openstudio_standards_data/database_files/support_schedules.json create mode 100644 data/openstudio_standards_data/database_tables/level_2_natural_gas_equipment.py create mode 100644 data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2007.py create mode 100644 data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2010.py create mode 100644 data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2013.py create mode 100644 data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2016.py create mode 100644 data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_1999.py create mode 100644 data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2007.py create mode 100644 data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2010.py create mode 100644 data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2013.py create mode 100644 data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2016.py create mode 100644 data/openstudio_standards_data/database_tables/support_lighting_technologies.py create mode 100644 data/openstudio_standards_data/database_tables/support_schedules.py diff --git a/data/openstudio_standards_data/applications/create_openstudio_standards_json.py b/data/openstudio_standards_data/applications/create_openstudio_standards_json.py index 3714269e51..715df4b3c5 100644 --- a/data/openstudio_standards_data/applications/create_openstudio_standards_json.py +++ b/data/openstudio_standards_data/applications/create_openstudio_standards_json.py @@ -36,7 +36,7 @@ def create_openstudio_standards_space_data_json( ventilation_standard_table = template["ventilation_standard_table"] # filter out the matching lighting standard table and ventilation standard table subset_space_map_table = filter( - lambda bldg: bldg["level_3_lighting_definition_table"] + lambda bldg: bldg["level_3_lighting_code_definition_table"] == lighting_standard_table and bldg["level_3_ventilation_definition_table"] == ventilation_standard_table, @@ -51,8 +51,8 @@ def create_openstudio_standards_space_data_json( sp_data["ventilation_standard"] = template["ventilation_standard"] sp_data["space_type"] = space["space_type"] - lpd_id = int(space["level_3_lighting_definition_id"]) - vent_id = int(space["level_3_ventilation_definition_id"]) + lpd_id = int(space["level_3_lighting_code_definition_id"]) + vent_id = int(space["level_3_ventilation_defintion_id"]) if lighting_standard_table not in standard_data_tables.keys(): light_table = fetch_table(conn, lighting_standard_table) standard_data_tables[lighting_standard_table] = light_table diff --git a/data/openstudio_standards_data/applications/form/update_space_data.py b/data/openstudio_standards_data/applications/form/update_space_data.py index 326ea493a3..c5624c2b4e 100644 --- a/data/openstudio_standards_data/applications/form/update_space_data.py +++ b/data/openstudio_standards_data/applications/form/update_space_data.py @@ -19,15 +19,15 @@ SPACE_TABLE_HEADER = [ "space_type", - "level_3_lighting_definition_id", - "level_3_ventilation_definition_id", + "level_3_lighting_code_definition_id", + "level_3_ventilation_defintion_id", ] FETCH_SPACE_TO_TABLE_QUEYR = f""" SELECT {','.join(SPACE_TABLE_HEADER)} FROM {GENERAL_SPACE_TYPE_TABLE_NAME} LEFT JOIN {LIGHT_SUBSPACES_TABLE_NAME} ON {GENERAL_SPACE_TYPE_TABLE_NAME}.lighting_space_type_name = {LIGHT_SUBSPACES_TABLE_NAME}.lighting_space_type_name LEFT JOIN {VENT_SUBSPACES_TABLE_NAME} ON {GENERAL_SPACE_TYPE_TABLE_NAME}.ventilation_space_type_name = {VENT_SUBSPACES_TABLE_NAME}.ventilation_space_type_name - WHERE space_type = '%s' AND level_3_lighting_definition_table = '%s' AND level_3_ventilation_definition_table = '%s' + WHERE space_type = '%s' AND level_3_lighting_code_definition_table = '%s' AND level_3_ventilation_definition_table = '%s' """ @@ -77,8 +77,8 @@ def update_openstudio_standards_space_data( # loop through the rows in table for row in cur: - level_3_lighting_definition_id = row[ - SPACE_TABLE_HEADER.index("level_3_lighting_definition_id") + level_3_lighting_code_definition_id = row[ + SPACE_TABLE_HEADER.index("level_3_lighting_code_definition_id") ] level_3_ventilation_definition_id = row[ SPACE_TABLE_HEADER.index("level_3_ventilation_definition_id") @@ -102,7 +102,7 @@ def update_openstudio_standards_space_data( search_condition = ( "id=%s AND lighting_primary_space_type='%s' AND lighting_secondary_space_type='%s'" % ( - level_3_lighting_definition_id, + level_3_lighting_code_definition_id, lighting_primary_space_type, lighting_secondary_space_type, ) @@ -113,13 +113,13 @@ def update_openstudio_standards_space_data( # update ventilation ventilation_update_dict = { - "ventilation_per_person": space_data.get("ventilation_per_person"), - "ventilation_per_person_unit": space_data.get( - "ventilation_per_person_unit" + "ventilation_rate": space_data.get("ventilation_rate"), + "ventilation_rate_occupant_unit": space_data.get( + "ventilation_rate_occupant_unit" ), - "ventilation_per_area": space_data.get("ventilation_per_area"), - "ventilation_per_area_unit": space_data.get( - "ventilation_per_area_unit" + "ventilation_rate_area": space_data.get("ventilation_rate_area"), + "ventilation_rate_area_unit": space_data.get( + "ventilation_rate_area_unit" ), "occupancy_per_area": space_data.get("occupancy_per_area"), "occupancy_per_area_unit": space_data.get("occupancy_per_area_unit"), diff --git a/data/openstudio_standards_data/client.py b/data/openstudio_standards_data/client.py index 9683bf6c1f..548d9e1650 100644 --- a/data/openstudio_standards_data/client.py +++ b/data/openstudio_standards_data/client.py @@ -35,10 +35,10 @@ "annotation": "", "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Auditorium seating area", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 150, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, diff --git a/data/openstudio_standards_data/database_files/level_1_space_types.csv b/data/openstudio_standards_data/database_files/level_1_space_types.csv index 0a94c3c794..e87d8506c9 100644 --- a/data/openstudio_standards_data/database_files/level_1_space_types.csv +++ b/data/openstudio_standards_data/database_files/level_1_space_types.csv @@ -1,129 +1,64 @@ -space_type_name,lighting_space_type_name,ventilation_space_type_name,electric_equipment_space_type_name -chapel - visually impaired,chapel_visually_impaired,public_assembly_spaces_religious_workshop, -recreation/common living - visually impaired,recreation_common_living_visually_impaired,hotels_motels_resorts_dormitories_multi_purpose_assembly, -atrium < 20 ft height,atrium_low,office_buildings_main_entry_lobbies,atrium < 20 ft height -atrium >= 20 ft and <= 40 ft in height,atrium_medium,office_buildings_main_entry_lobbies,atrium >= 20 ft and <= 40 ft in height -atrium > 40 ft height,atrium_high,office_buildings_main_entry_lobbies,atrium > 40 ft height -audience seating - convention center,audience_seating_convention_center,public_assembly_spaces_auditorium_seating_area,audience seating - convention center -audience seating - exercise center,audience_seating_exercise_center,sports_entertainment_spectator_areas,audience seating - exercise center -audience seating - all other,audience_seating_general,public_assembly_spaces_auditorium_seating_area,audience seating - all other -audience seating - auditorium,audience_seating_auditorium,public_assembly_spaces_auditorium_seating_area,audience seating - auditorium -audience seating - gymnasium,audience_seating_gymnasium,sports_entertainment_spectator_areas,audience seating - gymnasium -audience seating - sports arena,audience_seating_sports_arena,sports_entertainment_spectator_areas,audience seating - sports arena -audience seating - motion picture theater,audience_seating_motion_picture_theater,public_assembly_spaces_auditorium_seating_area,audience seating - motion picture theater -audience seating - penitentiary,audience_seating_penitentiary,public_assembly_spaces_auditorium_seating_area, -audience seating - performing arts theater,audience_seating_performing_arts_theater,public_assembly_spaces_auditorium_seating_area,audience seating - performing arts theater -audience seating - religious facility,audience_seating_religious_facility,public_assembly_spaces_auditorium_seating_area,audience seating - religious facility -audience seating - transportation facility,audience_seating_transportation,public_assembly_spaces_auditorium_seating_area, -automotive,automotive,miscellaneous_spaces_transportation_waiting, -banking activity,banking_activity,miscellaneous_spaces_banks_bank_lobbies,banking activity -classroom/lecture/training - all other,classroom_lecture_training_general,educational_facilities_classroom_old,classroom/lecture/training - all other -classroom/lecture/training - penitentiary,classroom_lecture_training_penitentiary,correctional_facilities_dayroom,classroom/lecture/training - penitentiary -classroom - laboratory or shop,laboratory_classroom,educational_facilities_university_college_laboratories, -classroom/lecture/training - preschool to 12th,classroom_lecture_training_general,educational_facilities_classroom_young,classroom/lecture/training - preschool to 12th -computer room,computer_room,miscellaneous_spaces_computer,computer room -conference/meeting/multipurpose,conference_meeting_multipurpose,general_conference_meeting,conference/meeting/multipurpose -confinement cells,confinement_cells,correctional_facilities_cell,confinement cells -exhibit - convention center,exhibit_convention_center,public_assembly_spaces_museums_galleries,exhibit - convention center -copy/print,copy_print,office_buildings_telephone_data_entry, -corridor for visually impaired,corridor_visually_impaired,general_conference_corridors, -corridor - hospital,corridor_hospital,general_conference_corridors,corridor - hospital -corridor - manufacturing facility,corridor_manufacturing_facility,general_conference_corridors,corridor - manufacturing facility -corridor - all other,corridor_general,general_conference_corridors,corridor - all other -courtroom,courtroom,public_assembly_spaces_courtrooms,courtroom -dining - all other,dining_general,food_beverage_service_restaurant_dining_rooms,dining - all other -dining - bar/lounge/leisure,dining_bar_lounge_leisure,food_beverage_service_bars_cocktail_lounges,dining - bar/lounge/leisure -dining - cafeteria/fast food,dining_cafeteria_fast_food,food_beverage_service_cafeteria_fast_food_dining,dining - cafeteria/fast food -dining for visually impaired,dining_visually_impaired,food_beverage_service_restaurant_dining_rooms, -dining - family,dining_family,food_beverage_service_restaurant_dining_rooms,dining - family -dining - penitentiary,dining_penitentiary,food_beverage_service_restaurant_dining_rooms,dining - penitentiary -dining - hotel,dining_hotel,food_beverage_service_restaurant_dining_rooms, -dining - motel,dining_motel,food_beverage_service_restaurant_dining_rooms, -dormitory - living quarters,dormitory_living_quarters,hotels_motels_resorts_dormitories_bedroom_living_room,dormitory - living quarters -electrical/mechanical,electrical_mechanical,miscellaneous_spaces_manufacturing_wo_hazardous_materials,electrical/mechanical -emergency vehicle garage,emergency_vehicle_garage,miscellaneous_spaces_transportation_waiting,emergency vehicle garage -firestation - sleeping quarters,firestation_sleeping_quarters,hotels_motels_resorts_dormitories_barracks_sleeping_areas,firestation - sleeping quarters -kitchen,kitchen,food_beverage_service_kitchen,kitchen -guest room,guest_room,hotels_motels_resorts_dormitories_barracks_sleeping_areas,guest room -gymnasium exercise area,gymnasium_exercise_area,sports_entertainment_gym_stadium,gymnasium exercise area -gymnasium playing area,gymnasium_playing_area,sports_entertainment_gym_stadium,gymnasium playing area -emergency room,emergency_room,outpatient_health_care_facilities_general_examination_room,emergency room -exam/treatment,exam_treatment,outpatient_health_care_facilities_general_examination_room,exam/treatment -imaging,imaging,outpatient_health_care_facilities_class_1_imaging_rooms, -medical supply,medical_supply,miscellaneous_spaces_pharmacy, -nursery,nursery,outpatient_health_care_facilities_psychiatric_consultation_room, -nurses station,nurses_station,outpatient_health_care_facilities_psychiatric_consultation_room,nurses station -operating room,operating_room,outpatient_health_care_facilities_general_examination_room,operating room -patient room,patient_room,outpatient_health_care_facilities_physical_therapy_individual_room,patient room -physical therapy,physical_therapy,outpatient_health_care_facilities_physical_therapy_exercise_area,physical therapy -recovery,recovery,outpatient_health_care_facilities_urgent_care_examination_room, -judges chambers,judges_chambers,public_assembly_spaces_legislative_chambers,judges chambers -laboratory,laboratory_all_other,educational_facilities_science_laboratories,laboratory -library - reading,library_reading,public_assembly_spaces_libraries,library - reading -library - stacks,library_stacks,public_assembly_spaces_libraries,library - stacks -library - cataloging,library_cataloging,public_assembly_spaces_libraries,library - cataloging -loading dock,loading_dock,miscellaneous_spaces_sorting_packing_light_assembly, -lobby - all other,lobby_general,public_assembly_spaces_lobbies,lobby - all other -lobby - elevator,lobby_elevator,public_assembly_spaces_lobbies,lobby - elevator -lobby for visually impaired,lobby_visually_impaired,public_assembly_spaces_lobbies, -lobby - hotel,lobby_hotel,hotels_motels_resorts_dormitories_lobbies_prefunction,lobby - hotel -lobby - motion picture theater,lobby_motion_picture_theater,public_assembly_spaces_lobbies,lobby - motion picture theater -lobby - performing arts theater,lobby_performing_arts_theater,public_assembly_spaces_lobbies,lobby - performing arts theater -locker room,locker_room,general_break_rooms,locker room -lounge/breakroom - all other,lounge_breakroom_general,general_break_rooms,lounge/breakroom - all other -lounge/breakroom - healthcare facility,lounge_breakroom_healthcare_facility,general_break_rooms,lounge/breakroom - healthcare facility -laundry/washing,laundry_washing,hotels_motels_resorts_dormitories_laundry_rooms,laundry/washing -detailed manufacuring,detailed_manufacuring,miscellaneous_spaces_manufacturing_wo_hazardous_materials, -manufacturing equipment room,manufacturing_equipment_room,miscellaneous_spaces_manufacturing_wo_hazardous_materials,manufacturing equipment room -manufacturing extra high bay,manufacturing_extra_high_bay,miscellaneous_spaces_manufacturing_wo_hazardous_materials, -manufacturing high bay,manufacturing_high_bay,miscellaneous_spaces_manufacturing_wo_hazardous_materials, -manufacturing low bay,manufacturing_low_bay,miscellaneous_spaces_manufacturing_wo_hazardous_materials,manufacturing low bay -manufacturing control,manufacturing_control,miscellaneous_spaces_manufacturing_wo_hazardous_materials, -museum exhibit area,museum_exhibit_area,public_assembly_spaces_museums_galleries,museum exhibit area -museum restoration,museum_restoration,public_assembly_spaces_museums_galleries,museum restoration -performing arts dressing room,performing_arts_dressing_room,retail_mall_common_areas,performing arts dressing room -office - enclosed <= 250 sf,office_enclosed_small,office_buildings_office_space,office - enclosed <= 250 sf -office - enclosed > 250 sf,office_enclosed_large,office_buildings_office_space,office - enclosed > 250 sf -office - open,office_open,office_buildings_office_space,office - open -"parking area, interior",parking_area_interior,miscellaneous_spaces_transportation_waiting,"parking area, interior" -pharmacy,pharmacy,miscellaneous_spaces_pharmacy,pharmacy -post office - sorting area,post_office_sorting_area,miscellaneous_spaces_sorting_packing_light_assembly,post office - sorting area -fellowship hall - religious facility,fellowship_hall_religious_facility,public_assembly_spaces_religious_workshop,fellowship hall - religious facility -worship/pulpit/choir area,worship_pulpit_choir_area,public_assembly_spaces_religious_workshop,worship/pulpit/choir area -restroom - all other,restroom_all_other,,restroom - all other -restroom - visually impaired,restroom_visually_impaired,, -retail dressing room,retail_dressing_room,retail_mall_common_areas, -retail mall concourse,retail_mall_concourse,retail_mall_common_areas, -"seating area, general",seating_area_general,public_assembly_spaces_auditorium_seating_area,"seating area, general" -"sports arena playing area, class I",sports_arena_playing_area_class_I,sports_entertainment_sports_arena, -"sports arena playing area, class II",sports_arena_playing_area_class_II,sports_entertainment_sports_arena,"sports arena playing area, class II" -"sports arena playing area, class III",sports_arena_playing_area_class_III,sports_entertainment_sports_arena, -"sports arena playing area, class IV",sports_arena_playing_area_class_IV,sports_entertainment_sports_arena,"sports arena playing area, class IV" -sports arena - ring sports area,sports_arena_ring_sports_area,sports_entertainment_sports_arena, -sports arena - court sports area,sports_arena_court_sports_area,sports_entertainment_sports_arena, -sports arena - indoor playing field,sports_arena_indoor_playing_field,sports_entertainment_sports_arena, -stairwell,stairwell,general_conference_corridors,stairwell -storage < 50 sf - all other,storage_ all_other_small,general_conference_storage_rooms,storage < 50 sf - all other -storage 50 to 1000 sf - all other,storage_ all_other_large,general_conference_storage_rooms,storage 50 to 1000 sf - all other -storage < 50 sf - hospital,storage_hospital_small,general_conference_storage_rooms,storage < 50 sf - hospital -storage 50 to 1000 sf - hospital,storage_hospital_large,general_conference_storage_rooms,storage 50 to 1000 sf - hospital -storage - inactive,storage_inactive,general_conference_storage_rooms,storage - inactive -"storage, inactive - museum",storage_inactive_museum,general_conference_storage_rooms, -airport concourse,airport_concourse,office_buildings_reception_areas,airport concourse -baggage/carousel,baggage_carousel,office_buildings_reception_areas,baggage/carousel -transportation ticket counter,transportation_ticket_counter,office_buildings_reception_areas,transportation ticket counter -vehicular maintenance,vehicular_maintenance,miscellaneous_spaces_manufacturing_wo_hazardous_materials,vehicular maintenance -warehouse - bulk storage,warehouse_bulk_storage,miscellaneous_spaces_warehouses,warehouse - bulk storage -warehouse - fine storage,warehouse_fine_storage,miscellaneous_spaces_warehouses,warehouse - fine storage -workshop,workshop,miscellaneous_spaces_manufacturing_wo_hazardous_materials,workshop -sales,sales,retail_sales,sales -sales - display type 1,sales_display_type_1,retail_sales, -sales - display type 2,sales_display_type_2,retail_sales, -sales - display type 3,sales_display_type_3,retail_sales, -sales - display type 4,sales_display_type_4,retail_sales, -guest room - highway,guest_room,hotels_motels_resorts_dormitories_barracks_sleeping_areas, -lodging dining - highway,dining_general,food_beverage_service_restaurant_dining_rooms, -audience seating - classroom/lecture/training,audience_seating_general,public_assembly_spaces_auditorium_seating_area, -audience seating - conference/meeting/multipurpose,audience_seating_general,public_assembly_spaces_auditorium_seating_area, -audience seating - corridor/transition,audience_seating_general,public_assembly_spaces_auditorium_seating_area, -guest room - bathroom,guest_room,hotels_motels_resorts_dormitories_barracks_sleeping_areas, +space_type_name,lighting_space_type_name,ventilation_space_type_name,electric_equipment_space_type_name,natural_gas_equipment_space_type_name,schedule_set_name +airport concourse,airport_concourse_lighting,airport_concourse_ventilation,airport_concourse_electric_equipment,,airport_concourse +atrium,atrium_lighting,atrium_ventilation,atrium_lt_20_ft_height_electric_equipment,,atrium_lt_20_ft_height +attic,none_lighting,attic_ventilation,attic_electric_equipment,,attic +audience seating,audience_seating_lighting,audience_seating_ventilation,audience_seating_all_other_electric_equipment,,audience_seating_all_other +baggage/carousel,baggage_carousel_lighting,baggage_carousel_ventilation,baggage_carousel_electric_equipment,,baggage_carousel +banking,banking_lighting,banking_ventilation,banking_activity_electric_equipment,,banking_activity +classroom/lecture/training,classroom_lecture_training_lighting,classroom_lecture_training_ventilation,classroom_lecture_training_all_other_electric_equipment,,classroom_lecture_training_all_other +computer room,computer_room_lighting,computer_room_ventilation,computer_room_electric_equipment,,computer_room +conference/meeting/multipurpose,conference_meeting_multipurpose_lighting,conference_meeting_multipurpose_ventilation,conference_meeting_multipurpose_electric_equipment,,conference_meeting_multipurpose +confinement cells,confinement_cells_lighting,confinement_cells_ventilation,confinement_cells_electric_equipment,,confinement_cells +copy/print,copy_print_lighting,copy_print_ventilation,,, +corridor,corridor_lighting,corridor_ventilation,corridor_all_other_electric_equipment,,corridor_all_other +courtroom,courtroom_lighting,courtroom_ventilation,courtroom_electric_equipment,,courtroom +datacenterHighITE,datacenterhighite_lighting,datacenterhighite_ventilation,,, +datacenterLowITE,datacenterlowite_lighting,datacenterlowite_ventilation,,, +dining,dining_lighting,dining_ventilation,dining_all_other_electric_equipment,,dining_all_other +dressing room,dressing_room_lighting,dressing_room_ventilation,performing_arts_dressing_room_electric_equipment,,performing_arts_dressing_room +electrical/mechanical,electrical_mechanical_lighting,electrical_mechanical_ventilation,electrical_mechanical_electric_equipment,,electrical_mechanical +emergency room,emergency_room_lighting,emergency_room_ventilation,emergency_room_electric_equipment,,emergency_room +emergency vehicle garage,emergency_vehicle_garage_lighting,emergency_vehicle_garage_ventilation,emergency_vehicle_garage_electric_equipment,,emergency_vehicle_garage +exam/treatment,exam_treatment_lighting,exam_treatment_ventilation,exam_treatment_electric_equipment,,exam_treatment +exercise area,exercise_area_lighting,exercise_area_ventilation,gymnasium_exercise_area_electric_equipment,,gymnasium_exercise_area +exhibit,exhibit_lighting,exhibit_ventilation,museum_exhibit_area_electric_equipment,,museum_exhibit_area +guest room,guest_room_lighting,guest_room_ventilation,guest_room_electric_equipment,,guest_room +imaging,imaging_lighting,imaging_ventilation,,, +interior parking,interior_parking_lighting,interior_parking_ventilation,parking_area_interior_electric_equipment,,parking_area_interior +judges chambers,judges_chambers_lighting,judges_chambers_ventilation,judges_chambers_electric_equipment,,judges_chambers +food preparation,food_preparation_lighting,food_preparation_ventilation,kitchen_electric_equipment,kitchen,kitchen +laboratory,laboratory_lighting,laboratory_ventilation,laboratory_electric_equipment,,laboratory +laundry/washing,laundry_washing_lighting,laundry_washing_ventilation,laundry_washing_electric_equipment,laundry,laundry_washing +library,library_lighting,library_ventilation,library_stacks_electric_equipment,,library_stacks +living quarters,living_quarters_lighting,living_quarters_ventilation,dormitory_living_quarters_electric_equipment,,dormitory_living_quarters +loading dock,loading_dock_lighting,loading_dock_ventilation,,, +lobby,lobby_lighting,lobby_ventilation,lobby_all_other_electric_equipment,,lobby_all_other +locker room,locker_room_lighting,locker_room_ventilation,locker_room_electric_equipment,,locker_room +lounge/breakroom,lounge_breakroom_lighting,lounge_breakroom_ventilation,lounge_breakroom_all_other_electric_equipment,,lounge_breakroom_all_other +manufacturing,manufacturing_lighting,manufacturing_ventilation,manufacturing_low_bay_electric_equipment,,manufacturing_low_bay +medical supply,medical_supply_lighting,medical_supply_ventilation,pharmacy_electric_equipment,,pharmacy +multifamily,multifamily_lighting,multifamily_ventilation,,, +nursery,nursery_lighting,nursery_ventilation,patient_room_electric_equipment,,patient_room +nurses station,nurses_station_lighting,nurses_station_ventilation,nurses_station_electric_equipment,,nurses_station +office,office_lighting,office_ventilation,office_open_electric_equipment,,office_open +"office, enclosed",office_enclosed_lighting,office_enclosed_ventilation,office_enclosed_lte_250_sf_electric_equipment,,office_enclosed_lte_250_sf +operating room,operating_room_lighting,operating_room_ventilation,operating_room_electric_equipment,,operating_room +patient room,patient_room_lighting,patient_room_ventilation,patient_room_electric_equipment,,patient_room +pharmacy,pharmacy_lighting,pharmacy_ventilation,pharmacy_electric_equipment,,pharmacy +physical therapy,physical_therapy_lighting,physical_therapy_ventilation,physical_therapy_electric_equipment,,physical_therapy +playing area,playing_area_lighting,playing_area_ventilation,gymnasium_playing_area_electric_equipment,,gymnasium_playing_area +plenum,none_lighting,plenum_ventilation,plenum_electric_equipment,,plenum +post office,post_office_lighting,post_office_ventilation,post_office_sorting_area_electric_equipment,,post_office_sorting_area +recovery,recovery_lighting,recovery_ventilation,patient_room_electric_equipment,,patient_room +recreation/common living,recreation_common_living_lighting,recreation_common_living_ventilation,lounge_breakroom_all_other_electric_equipment,,lounge_breakroom_all_other +restroom,restroom_lighting,restroom_ventilation,restroom_all_other_electric_equipment,,restroom_all_other +retail,retail_sales_lighting,retail_sales_ventilation,sales_electric_equipment,,sales +shaft,none_lighting,shaft_ventilation,shaft_electric_equipment,,shaft +sleeping quarters,sleeping_quarters_lighting,sleeping_quarters_ventilation,firestation_sleeping_quarters_electric_equipment,,firestation_sleeping_quarters +sports arena,sports_arena_lighting,sports_arena_ventilation,sports_arena_playing_area_class_ii_electric_equipment,,sports_arena_playing_area_class_ii +stairwell,stairwell_lighting,stairwell_ventilation,stairwell_electric_equipment,,stairwell +storage,storage_lighting,storage_ventilation,storage_50_to_1000_sf_all_other_electric_equipment,,storage_50_to_1000_sf_all_other +transportation,transportation_lighting,transportation_ventilation,transportation_ticket_counter_electric_equipment,,transportation_ticket_counter +vehicular maintenance,vehicular_maintenance_lighting,vehicular_maintenance_ventilation,vehicular_maintenance_electric_equipment,,vehicular_maintenance +workshop,workshop_lighting,workshop_ventilation,workshop_electric_equipment,,workshop +worship,worship_lighting,worship_ventilation,worship_pulpit_choir_area_electric_equipment,,worship_pulpit_choir_area diff --git a/data/openstudio_standards_data/database_files/level_1_space_types.json b/data/openstudio_standards_data/database_files/level_1_space_types.json index d54e912e00..570d8c86ca 100644 --- a/data/openstudio_standards_data/database_files/level_1_space_types.json +++ b/data/openstudio_standards_data/database_files/level_1_space_types.json @@ -1,770 +1,506 @@ [ { - "space_type_name": "chapel - visually impaired", - "lighting_space_type_name": "chapel_visually_impaired", - "ventilation_space_type_name": "public_assembly_spaces_religious_workshop", - "electric_equipment_space_type_name": null - }, - { - "space_type_name": "recreation/common living - visually impaired", - "lighting_space_type_name": "recreation_common_living_visually_impaired", - "ventilation_space_type_name": "hotels_motels_resorts_dormitories_multi_purpose_assembly", - "electric_equipment_space_type_name": null - }, - { - "space_type_name": "atrium < 20 ft height", - "lighting_space_type_name": "atrium_low", - "ventilation_space_type_name": "office_buildings_main_entry_lobbies", - "electric_equipment_space_type_name": "atrium < 20 ft height" - }, - { - "space_type_name": "atrium >= 20 ft and <= 40 ft in height", - "lighting_space_type_name": "atrium_medium", - "ventilation_space_type_name": "office_buildings_main_entry_lobbies", - "electric_equipment_space_type_name": "atrium >= 20 ft and <= 40 ft in height" - }, - { - "space_type_name": "atrium > 40 ft height", - "lighting_space_type_name": "atrium_high", - "ventilation_space_type_name": "office_buildings_main_entry_lobbies", - "electric_equipment_space_type_name": "atrium > 40 ft height" - }, - { - "space_type_name": "audience seating - convention center", - "lighting_space_type_name": "audience_seating_convention_center", - "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", - "electric_equipment_space_type_name": "audience seating - convention center" - }, - { - "space_type_name": "audience seating - exercise center", - "lighting_space_type_name": "audience_seating_exercise_center", - "ventilation_space_type_name": "sports_entertainment_spectator_areas", - "electric_equipment_space_type_name": "audience seating - exercise center" - }, - { - "space_type_name": "audience seating - all other", - "lighting_space_type_name": "audience_seating_general", - "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", - "electric_equipment_space_type_name": "audience seating - all other" - }, - { - "space_type_name": "audience seating - auditorium", - "lighting_space_type_name": "audience_seating_auditorium", - "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", - "electric_equipment_space_type_name": "audience seating - auditorium" - }, - { - "space_type_name": "audience seating - gymnasium", - "lighting_space_type_name": "audience_seating_gymnasium", - "ventilation_space_type_name": "sports_entertainment_spectator_areas", - "electric_equipment_space_type_name": "audience seating - gymnasium" - }, - { - "space_type_name": "audience seating - sports arena", - "lighting_space_type_name": "audience_seating_sports_arena", - "ventilation_space_type_name": "sports_entertainment_spectator_areas", - "electric_equipment_space_type_name": "audience seating - sports arena" - }, - { - "space_type_name": "audience seating - motion picture theater", - "lighting_space_type_name": "audience_seating_motion_picture_theater", - "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", - "electric_equipment_space_type_name": "audience seating - motion picture theater" - }, - { - "space_type_name": "audience seating - penitentiary", - "lighting_space_type_name": "audience_seating_penitentiary", - "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", - "electric_equipment_space_type_name": null - }, - { - "space_type_name": "audience seating - performing arts theater", - "lighting_space_type_name": "audience_seating_performing_arts_theater", - "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", - "electric_equipment_space_type_name": "audience seating - performing arts theater" - }, - { - "space_type_name": "audience seating - religious facility", - "lighting_space_type_name": "audience_seating_religious_facility", - "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", - "electric_equipment_space_type_name": "audience seating - religious facility" - }, - { - "space_type_name": "audience seating - transportation facility", - "lighting_space_type_name": "audience_seating_transportation", - "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", - "electric_equipment_space_type_name": null + "space_type_name": "airport concourse", + "lighting_space_type_name": "airport_concourse_lighting", + "ventilation_space_type_name": "airport_concourse_ventilation", + "electric_equipment_space_type_name": "airport_concourse_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "airport_concourse" }, { - "space_type_name": "automotive", - "lighting_space_type_name": "automotive", - "ventilation_space_type_name": "miscellaneous_spaces_transportation_waiting", - "electric_equipment_space_type_name": null + "space_type_name": "atrium", + "lighting_space_type_name": "atrium_lighting", + "ventilation_space_type_name": "atrium_ventilation", + "electric_equipment_space_type_name": "atrium_lt_20_ft_height_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "atrium_lt_20_ft_height" }, { - "space_type_name": "banking activity", - "lighting_space_type_name": "banking_activity", - "ventilation_space_type_name": "miscellaneous_spaces_banks_bank_lobbies", - "electric_equipment_space_type_name": "banking activity" + "space_type_name": "attic", + "lighting_space_type_name": "none_lighting", + "ventilation_space_type_name": "attic_ventilation", + "electric_equipment_space_type_name": "attic_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "attic" }, { - "space_type_name": "classroom/lecture/training - all other", - "lighting_space_type_name": "classroom_lecture_training_general", - "ventilation_space_type_name": "educational_facilities_classroom_old", - "electric_equipment_space_type_name": "classroom/lecture/training - all other" + "space_type_name": "audience seating", + "lighting_space_type_name": "audience_seating_lighting", + "ventilation_space_type_name": "audience_seating_ventilation", + "electric_equipment_space_type_name": "audience_seating_all_other_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "audience_seating_all_other" }, { - "space_type_name": "classroom/lecture/training - penitentiary", - "lighting_space_type_name": "classroom_lecture_training_penitentiary", - "ventilation_space_type_name": "correctional_facilities_dayroom", - "electric_equipment_space_type_name": "classroom/lecture/training - penitentiary" + "space_type_name": "baggage/carousel", + "lighting_space_type_name": "baggage_carousel_lighting", + "ventilation_space_type_name": "baggage_carousel_ventilation", + "electric_equipment_space_type_name": "baggage_carousel_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "baggage_carousel" }, { - "space_type_name": "classroom - laboratory or shop", - "lighting_space_type_name": "laboratory_classroom", - "ventilation_space_type_name": "educational_facilities_university_college_laboratories", - "electric_equipment_space_type_name": null + "space_type_name": "banking", + "lighting_space_type_name": "banking_lighting", + "ventilation_space_type_name": "banking_ventilation", + "electric_equipment_space_type_name": "banking_activity_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "banking_activity" }, { - "space_type_name": "classroom/lecture/training - preschool to 12th", - "lighting_space_type_name": "classroom_lecture_training_general", - "ventilation_space_type_name": "educational_facilities_classroom_young", - "electric_equipment_space_type_name": "classroom/lecture/training - preschool to 12th" + "space_type_name": "classroom/lecture/training", + "lighting_space_type_name": "classroom_lecture_training_lighting", + "ventilation_space_type_name": "classroom_lecture_training_ventilation", + "electric_equipment_space_type_name": "classroom_lecture_training_all_other_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "classroom_lecture_training_all_other" }, { "space_type_name": "computer room", - "lighting_space_type_name": "computer_room", - "ventilation_space_type_name": "miscellaneous_spaces_computer", - "electric_equipment_space_type_name": "computer room" + "lighting_space_type_name": "computer_room_lighting", + "ventilation_space_type_name": "computer_room_ventilation", + "electric_equipment_space_type_name": "computer_room_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "computer_room" }, { "space_type_name": "conference/meeting/multipurpose", - "lighting_space_type_name": "conference_meeting_multipurpose", - "ventilation_space_type_name": "general_conference_meeting", - "electric_equipment_space_type_name": "conference/meeting/multipurpose" + "lighting_space_type_name": "conference_meeting_multipurpose_lighting", + "ventilation_space_type_name": "conference_meeting_multipurpose_ventilation", + "electric_equipment_space_type_name": "conference_meeting_multipurpose_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "conference_meeting_multipurpose" }, { "space_type_name": "confinement cells", - "lighting_space_type_name": "confinement_cells", - "ventilation_space_type_name": "correctional_facilities_cell", - "electric_equipment_space_type_name": "confinement cells" - }, - { - "space_type_name": "exhibit - convention center", - "lighting_space_type_name": "exhibit_convention_center", - "ventilation_space_type_name": "public_assembly_spaces_museums_galleries", - "electric_equipment_space_type_name": "exhibit - convention center" + "lighting_space_type_name": "confinement_cells_lighting", + "ventilation_space_type_name": "confinement_cells_ventilation", + "electric_equipment_space_type_name": "confinement_cells_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "confinement_cells" }, { "space_type_name": "copy/print", - "lighting_space_type_name": "copy_print", - "ventilation_space_type_name": "office_buildings_telephone_data_entry", - "electric_equipment_space_type_name": null - }, - { - "space_type_name": "corridor for visually impaired", - "lighting_space_type_name": "corridor_visually_impaired", - "ventilation_space_type_name": "general_conference_corridors", - "electric_equipment_space_type_name": null + "lighting_space_type_name": "copy_print_lighting", + "ventilation_space_type_name": "copy_print_ventilation", + "electric_equipment_space_type_name": null, + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": null }, { - "space_type_name": "corridor - hospital", - "lighting_space_type_name": "corridor_hospital", - "ventilation_space_type_name": "general_conference_corridors", - "electric_equipment_space_type_name": "corridor - hospital" - }, - { - "space_type_name": "corridor - manufacturing facility", - "lighting_space_type_name": "corridor_manufacturing_facility", - "ventilation_space_type_name": "general_conference_corridors", - "electric_equipment_space_type_name": "corridor - manufacturing facility" - }, - { - "space_type_name": "corridor - all other", - "lighting_space_type_name": "corridor_general", - "ventilation_space_type_name": "general_conference_corridors", - "electric_equipment_space_type_name": "corridor - all other" + "space_type_name": "corridor", + "lighting_space_type_name": "corridor_lighting", + "ventilation_space_type_name": "corridor_ventilation", + "electric_equipment_space_type_name": "corridor_all_other_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "corridor_all_other" }, { "space_type_name": "courtroom", - "lighting_space_type_name": "courtroom", - "ventilation_space_type_name": "public_assembly_spaces_courtrooms", - "electric_equipment_space_type_name": "courtroom" + "lighting_space_type_name": "courtroom_lighting", + "ventilation_space_type_name": "courtroom_ventilation", + "electric_equipment_space_type_name": "courtroom_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "courtroom" }, { - "space_type_name": "dining - all other", - "lighting_space_type_name": "dining_general", - "ventilation_space_type_name": "food_beverage_service_restaurant_dining_rooms", - "electric_equipment_space_type_name": "dining - all other" + "space_type_name": "datacenterHighITE", + "lighting_space_type_name": "datacenterhighite_lighting", + "ventilation_space_type_name": "datacenterhighite_ventilation", + "electric_equipment_space_type_name": null, + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": null }, { - "space_type_name": "dining - bar/lounge/leisure", - "lighting_space_type_name": "dining_bar_lounge_leisure", - "ventilation_space_type_name": "food_beverage_service_bars_cocktail_lounges", - "electric_equipment_space_type_name": "dining - bar/lounge/leisure" + "space_type_name": "datacenterLowITE", + "lighting_space_type_name": "datacenterlowite_lighting", + "ventilation_space_type_name": "datacenterlowite_ventilation", + "electric_equipment_space_type_name": null, + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": null }, { - "space_type_name": "dining - cafeteria/fast food", - "lighting_space_type_name": "dining_cafeteria_fast_food", - "ventilation_space_type_name": "food_beverage_service_cafeteria_fast_food_dining", - "electric_equipment_space_type_name": "dining - cafeteria/fast food" + "space_type_name": "dining", + "lighting_space_type_name": "dining_lighting", + "ventilation_space_type_name": "dining_ventilation", + "electric_equipment_space_type_name": "dining_all_other_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "dining_all_other" }, { - "space_type_name": "dining for visually impaired", - "lighting_space_type_name": "dining_visually_impaired", - "ventilation_space_type_name": "food_beverage_service_restaurant_dining_rooms", - "electric_equipment_space_type_name": null - }, - { - "space_type_name": "dining - family", - "lighting_space_type_name": "dining_family", - "ventilation_space_type_name": "food_beverage_service_restaurant_dining_rooms", - "electric_equipment_space_type_name": "dining - family" - }, - { - "space_type_name": "dining - penitentiary", - "lighting_space_type_name": "dining_penitentiary", - "ventilation_space_type_name": "food_beverage_service_restaurant_dining_rooms", - "electric_equipment_space_type_name": "dining - penitentiary" - }, - { - "space_type_name": "dining - hotel", - "lighting_space_type_name": "dining_hotel", - "ventilation_space_type_name": "food_beverage_service_restaurant_dining_rooms", - "electric_equipment_space_type_name": null - }, - { - "space_type_name": "dining - motel", - "lighting_space_type_name": "dining_motel", - "ventilation_space_type_name": "food_beverage_service_restaurant_dining_rooms", - "electric_equipment_space_type_name": null - }, - { - "space_type_name": "dormitory - living quarters", - "lighting_space_type_name": "dormitory_living_quarters", - "ventilation_space_type_name": "hotels_motels_resorts_dormitories_bedroom_living_room", - "electric_equipment_space_type_name": "dormitory - living quarters" + "space_type_name": "dressing room", + "lighting_space_type_name": "dressing_room_lighting", + "ventilation_space_type_name": "dressing_room_ventilation", + "electric_equipment_space_type_name": "performing_arts_dressing_room_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "performing_arts_dressing_room" }, { "space_type_name": "electrical/mechanical", - "lighting_space_type_name": "electrical_mechanical", - "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", - "electric_equipment_space_type_name": "electrical/mechanical" - }, - { - "space_type_name": "emergency vehicle garage", - "lighting_space_type_name": "emergency_vehicle_garage", - "ventilation_space_type_name": "miscellaneous_spaces_transportation_waiting", - "electric_equipment_space_type_name": "emergency vehicle garage" - }, - { - "space_type_name": "firestation - sleeping quarters", - "lighting_space_type_name": "firestation_sleeping_quarters", - "ventilation_space_type_name": "hotels_motels_resorts_dormitories_barracks_sleeping_areas", - "electric_equipment_space_type_name": "firestation - sleeping quarters" - }, - { - "space_type_name": "kitchen", - "lighting_space_type_name": "kitchen", - "ventilation_space_type_name": "food_beverage_service_kitchen", - "electric_equipment_space_type_name": "kitchen" - }, - { - "space_type_name": "guest room", - "lighting_space_type_name": "guest_room", - "ventilation_space_type_name": "hotels_motels_resorts_dormitories_barracks_sleeping_areas", - "electric_equipment_space_type_name": "guest room" - }, - { - "space_type_name": "gymnasium exercise area", - "lighting_space_type_name": "gymnasium_exercise_area", - "ventilation_space_type_name": "sports_entertainment_gym_stadium", - "electric_equipment_space_type_name": "gymnasium exercise area" - }, - { - "space_type_name": "gymnasium playing area", - "lighting_space_type_name": "gymnasium_playing_area", - "ventilation_space_type_name": "sports_entertainment_gym_stadium", - "electric_equipment_space_type_name": "gymnasium playing area" + "lighting_space_type_name": "electrical_mechanical_lighting", + "ventilation_space_type_name": "electrical_mechanical_ventilation", + "electric_equipment_space_type_name": "electrical_mechanical_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "electrical_mechanical" }, { "space_type_name": "emergency room", - "lighting_space_type_name": "emergency_room", - "ventilation_space_type_name": "outpatient_health_care_facilities_general_examination_room", - "electric_equipment_space_type_name": "emergency room" - }, - { - "space_type_name": "exam/treatment", - "lighting_space_type_name": "exam_treatment", - "ventilation_space_type_name": "outpatient_health_care_facilities_general_examination_room", - "electric_equipment_space_type_name": "exam/treatment" + "lighting_space_type_name": "emergency_room_lighting", + "ventilation_space_type_name": "emergency_room_ventilation", + "electric_equipment_space_type_name": "emergency_room_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "emergency_room" }, { - "space_type_name": "imaging", - "lighting_space_type_name": "imaging", - "ventilation_space_type_name": "outpatient_health_care_facilities_class_1_imaging_rooms", - "electric_equipment_space_type_name": null + "space_type_name": "emergency vehicle garage", + "lighting_space_type_name": "emergency_vehicle_garage_lighting", + "ventilation_space_type_name": "emergency_vehicle_garage_ventilation", + "electric_equipment_space_type_name": "emergency_vehicle_garage_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "emergency_vehicle_garage" }, { - "space_type_name": "medical supply", - "lighting_space_type_name": "medical_supply", - "ventilation_space_type_name": "miscellaneous_spaces_pharmacy", - "electric_equipment_space_type_name": null + "space_type_name": "exam/treatment", + "lighting_space_type_name": "exam_treatment_lighting", + "ventilation_space_type_name": "exam_treatment_ventilation", + "electric_equipment_space_type_name": "exam_treatment_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "exam_treatment" }, { - "space_type_name": "nursery", - "lighting_space_type_name": "nursery", - "ventilation_space_type_name": "outpatient_health_care_facilities_psychiatric_consultation_room", - "electric_equipment_space_type_name": null + "space_type_name": "exercise area", + "lighting_space_type_name": "exercise_area_lighting", + "ventilation_space_type_name": "exercise_area_ventilation", + "electric_equipment_space_type_name": "gymnasium_exercise_area_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "gymnasium_exercise_area" }, { - "space_type_name": "nurses station", - "lighting_space_type_name": "nurses_station", - "ventilation_space_type_name": "outpatient_health_care_facilities_psychiatric_consultation_room", - "electric_equipment_space_type_name": "nurses station" + "space_type_name": "exhibit", + "lighting_space_type_name": "exhibit_lighting", + "ventilation_space_type_name": "exhibit_ventilation", + "electric_equipment_space_type_name": "museum_exhibit_area_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "museum_exhibit_area" }, { - "space_type_name": "operating room", - "lighting_space_type_name": "operating_room", - "ventilation_space_type_name": "outpatient_health_care_facilities_general_examination_room", - "electric_equipment_space_type_name": "operating room" + "space_type_name": "guest room", + "lighting_space_type_name": "guest_room_lighting", + "ventilation_space_type_name": "guest_room_ventilation", + "electric_equipment_space_type_name": "guest_room_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "guest_room" }, { - "space_type_name": "patient room", - "lighting_space_type_name": "patient_room", - "ventilation_space_type_name": "outpatient_health_care_facilities_physical_therapy_individual_room", - "electric_equipment_space_type_name": "patient room" + "space_type_name": "imaging", + "lighting_space_type_name": "imaging_lighting", + "ventilation_space_type_name": "imaging_ventilation", + "electric_equipment_space_type_name": null, + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": null }, { - "space_type_name": "physical therapy", - "lighting_space_type_name": "physical_therapy", - "ventilation_space_type_name": "outpatient_health_care_facilities_physical_therapy_exercise_area", - "electric_equipment_space_type_name": "physical therapy" + "space_type_name": "interior parking", + "lighting_space_type_name": "interior_parking_lighting", + "ventilation_space_type_name": "interior_parking_ventilation", + "electric_equipment_space_type_name": "parking_area_interior_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "parking_area_interior" }, { - "space_type_name": "recovery", - "lighting_space_type_name": "recovery", - "ventilation_space_type_name": "outpatient_health_care_facilities_urgent_care_examination_room", - "electric_equipment_space_type_name": null + "space_type_name": "judges chambers", + "lighting_space_type_name": "judges_chambers_lighting", + "ventilation_space_type_name": "judges_chambers_ventilation", + "electric_equipment_space_type_name": "judges_chambers_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "judges_chambers" }, { - "space_type_name": "judges chambers", - "lighting_space_type_name": "judges_chambers", - "ventilation_space_type_name": "public_assembly_spaces_legislative_chambers", - "electric_equipment_space_type_name": "judges chambers" + "space_type_name": "food preparation", + "lighting_space_type_name": "food_preparation_lighting", + "ventilation_space_type_name": "food_preparation_ventilation", + "electric_equipment_space_type_name": "kitchen_electric_equipment", + "natural_gas_equipment_space_type_name": "kitchen", + "schedule_set_name": "kitchen" }, { "space_type_name": "laboratory", - "lighting_space_type_name": "laboratory_all_other", - "ventilation_space_type_name": "educational_facilities_science_laboratories", - "electric_equipment_space_type_name": "laboratory" + "lighting_space_type_name": "laboratory_lighting", + "ventilation_space_type_name": "laboratory_ventilation", + "electric_equipment_space_type_name": "laboratory_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "laboratory" }, { - "space_type_name": "library - reading", - "lighting_space_type_name": "library_reading", - "ventilation_space_type_name": "public_assembly_spaces_libraries", - "electric_equipment_space_type_name": "library - reading" + "space_type_name": "laundry/washing", + "lighting_space_type_name": "laundry_washing_lighting", + "ventilation_space_type_name": "laundry_washing_ventilation", + "electric_equipment_space_type_name": "laundry_washing_electric_equipment", + "natural_gas_equipment_space_type_name": "laundry", + "schedule_set_name": "laundry_washing" }, { - "space_type_name": "library - stacks", - "lighting_space_type_name": "library_stacks", - "ventilation_space_type_name": "public_assembly_spaces_libraries", - "electric_equipment_space_type_name": "library - stacks" + "space_type_name": "library", + "lighting_space_type_name": "library_lighting", + "ventilation_space_type_name": "library_ventilation", + "electric_equipment_space_type_name": "library_stacks_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "library_stacks" }, { - "space_type_name": "library - cataloging", - "lighting_space_type_name": "library_cataloging", - "ventilation_space_type_name": "public_assembly_spaces_libraries", - "electric_equipment_space_type_name": "library - cataloging" + "space_type_name": "living quarters", + "lighting_space_type_name": "living_quarters_lighting", + "ventilation_space_type_name": "living_quarters_ventilation", + "electric_equipment_space_type_name": "dormitory_living_quarters_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "dormitory_living_quarters" }, { "space_type_name": "loading dock", - "lighting_space_type_name": "loading_dock", - "ventilation_space_type_name": "miscellaneous_spaces_sorting_packing_light_assembly", - "electric_equipment_space_type_name": null - }, - { - "space_type_name": "lobby - all other", - "lighting_space_type_name": "lobby_general", - "ventilation_space_type_name": "public_assembly_spaces_lobbies", - "electric_equipment_space_type_name": "lobby - all other" - }, - { - "space_type_name": "lobby - elevator", - "lighting_space_type_name": "lobby_elevator", - "ventilation_space_type_name": "public_assembly_spaces_lobbies", - "electric_equipment_space_type_name": "lobby - elevator" - }, - { - "space_type_name": "lobby for visually impaired", - "lighting_space_type_name": "lobby_visually_impaired", - "ventilation_space_type_name": "public_assembly_spaces_lobbies", - "electric_equipment_space_type_name": null - }, - { - "space_type_name": "lobby - hotel", - "lighting_space_type_name": "lobby_hotel", - "ventilation_space_type_name": "hotels_motels_resorts_dormitories_lobbies_prefunction", - "electric_equipment_space_type_name": "lobby - hotel" - }, - { - "space_type_name": "lobby - motion picture theater", - "lighting_space_type_name": "lobby_motion_picture_theater", - "ventilation_space_type_name": "public_assembly_spaces_lobbies", - "electric_equipment_space_type_name": "lobby - motion picture theater" + "lighting_space_type_name": "loading_dock_lighting", + "ventilation_space_type_name": "loading_dock_ventilation", + "electric_equipment_space_type_name": null, + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": null }, { - "space_type_name": "lobby - performing arts theater", - "lighting_space_type_name": "lobby_performing_arts_theater", - "ventilation_space_type_name": "public_assembly_spaces_lobbies", - "electric_equipment_space_type_name": "lobby - performing arts theater" + "space_type_name": "lobby", + "lighting_space_type_name": "lobby_lighting", + "ventilation_space_type_name": "lobby_ventilation", + "electric_equipment_space_type_name": "lobby_all_other_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "lobby_all_other" }, { "space_type_name": "locker room", - "lighting_space_type_name": "locker_room", - "ventilation_space_type_name": "general_break_rooms", - "electric_equipment_space_type_name": "locker room" + "lighting_space_type_name": "locker_room_lighting", + "ventilation_space_type_name": "locker_room_ventilation", + "electric_equipment_space_type_name": "locker_room_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "locker_room" }, { - "space_type_name": "lounge/breakroom - all other", - "lighting_space_type_name": "lounge_breakroom_general", - "ventilation_space_type_name": "general_break_rooms", - "electric_equipment_space_type_name": "lounge/breakroom - all other" + "space_type_name": "lounge/breakroom", + "lighting_space_type_name": "lounge_breakroom_lighting", + "ventilation_space_type_name": "lounge_breakroom_ventilation", + "electric_equipment_space_type_name": "lounge_breakroom_all_other_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "lounge_breakroom_all_other" }, { - "space_type_name": "lounge/breakroom - healthcare facility", - "lighting_space_type_name": "lounge_breakroom_healthcare_facility", - "ventilation_space_type_name": "general_break_rooms", - "electric_equipment_space_type_name": "lounge/breakroom - healthcare facility" + "space_type_name": "manufacturing", + "lighting_space_type_name": "manufacturing_lighting", + "ventilation_space_type_name": "manufacturing_ventilation", + "electric_equipment_space_type_name": "manufacturing_low_bay_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "manufacturing_low_bay" }, { - "space_type_name": "laundry/washing", - "lighting_space_type_name": "laundry_washing", - "ventilation_space_type_name": "hotels_motels_resorts_dormitories_laundry_rooms", - "electric_equipment_space_type_name": "laundry/washing" - }, - { - "space_type_name": "detailed manufacuring", - "lighting_space_type_name": "detailed_manufacuring", - "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", - "electric_equipment_space_type_name": null - }, - { - "space_type_name": "manufacturing equipment room", - "lighting_space_type_name": "manufacturing_equipment_room", - "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", - "electric_equipment_space_type_name": "manufacturing equipment room" - }, - { - "space_type_name": "manufacturing extra high bay", - "lighting_space_type_name": "manufacturing_extra_high_bay", - "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", - "electric_equipment_space_type_name": null - }, - { - "space_type_name": "manufacturing high bay", - "lighting_space_type_name": "manufacturing_high_bay", - "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", - "electric_equipment_space_type_name": null - }, - { - "space_type_name": "manufacturing low bay", - "lighting_space_type_name": "manufacturing_low_bay", - "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", - "electric_equipment_space_type_name": "manufacturing low bay" - }, - { - "space_type_name": "manufacturing control", - "lighting_space_type_name": "manufacturing_control", - "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", - "electric_equipment_space_type_name": null + "space_type_name": "medical supply", + "lighting_space_type_name": "medical_supply_lighting", + "ventilation_space_type_name": "medical_supply_ventilation", + "electric_equipment_space_type_name": "pharmacy_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "pharmacy" }, { - "space_type_name": "museum exhibit area", - "lighting_space_type_name": "museum_exhibit_area", - "ventilation_space_type_name": "public_assembly_spaces_museums_galleries", - "electric_equipment_space_type_name": "museum exhibit area" + "space_type_name": "multifamily", + "lighting_space_type_name": "multifamily_lighting", + "ventilation_space_type_name": "multifamily_ventilation", + "electric_equipment_space_type_name": null, + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": null }, { - "space_type_name": "museum restoration", - "lighting_space_type_name": "museum_restoration", - "ventilation_space_type_name": "public_assembly_spaces_museums_galleries", - "electric_equipment_space_type_name": "museum restoration" + "space_type_name": "nursery", + "lighting_space_type_name": "nursery_lighting", + "ventilation_space_type_name": "nursery_ventilation", + "electric_equipment_space_type_name": "patient_room_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "patient_room" }, { - "space_type_name": "performing arts dressing room", - "lighting_space_type_name": "performing_arts_dressing_room", - "ventilation_space_type_name": "retail_mall_common_areas", - "electric_equipment_space_type_name": "performing arts dressing room" + "space_type_name": "nurses station", + "lighting_space_type_name": "nurses_station_lighting", + "ventilation_space_type_name": "nurses_station_ventilation", + "electric_equipment_space_type_name": "nurses_station_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "nurses_station" }, { - "space_type_name": "office - enclosed <= 250 sf", - "lighting_space_type_name": "office_enclosed_small", - "ventilation_space_type_name": "office_buildings_office_space", - "electric_equipment_space_type_name": "office - enclosed <= 250 sf" + "space_type_name": "office", + "lighting_space_type_name": "office_lighting", + "ventilation_space_type_name": "office_ventilation", + "electric_equipment_space_type_name": "office_open_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "office_open" }, { - "space_type_name": "office - enclosed > 250 sf", - "lighting_space_type_name": "office_enclosed_large", - "ventilation_space_type_name": "office_buildings_office_space", - "electric_equipment_space_type_name": "office - enclosed > 250 sf" + "space_type_name": "office, enclosed", + "lighting_space_type_name": "office_enclosed_lighting", + "ventilation_space_type_name": "office_enclosed_ventilation", + "electric_equipment_space_type_name": "office_enclosed_lte_250_sf_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "office_enclosed_lte_250_sf" }, { - "space_type_name": "office - open", - "lighting_space_type_name": "office_open", - "ventilation_space_type_name": "office_buildings_office_space", - "electric_equipment_space_type_name": "office - open" + "space_type_name": "operating room", + "lighting_space_type_name": "operating_room_lighting", + "ventilation_space_type_name": "operating_room_ventilation", + "electric_equipment_space_type_name": "operating_room_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "operating_room" }, { - "space_type_name": "parking area, interior", - "lighting_space_type_name": "parking_area_interior", - "ventilation_space_type_name": "miscellaneous_spaces_transportation_waiting", - "electric_equipment_space_type_name": "parking area, interior" + "space_type_name": "patient room", + "lighting_space_type_name": "patient_room_lighting", + "ventilation_space_type_name": "patient_room_ventilation", + "electric_equipment_space_type_name": "patient_room_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "patient_room" }, { "space_type_name": "pharmacy", - "lighting_space_type_name": "pharmacy", - "ventilation_space_type_name": "miscellaneous_spaces_pharmacy", - "electric_equipment_space_type_name": "pharmacy" - }, - { - "space_type_name": "post office - sorting area", - "lighting_space_type_name": "post_office_sorting_area", - "ventilation_space_type_name": "miscellaneous_spaces_sorting_packing_light_assembly", - "electric_equipment_space_type_name": "post office - sorting area" + "lighting_space_type_name": "pharmacy_lighting", + "ventilation_space_type_name": "pharmacy_ventilation", + "electric_equipment_space_type_name": "pharmacy_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "pharmacy" }, { - "space_type_name": "fellowship hall - religious facility", - "lighting_space_type_name": "fellowship_hall_religious_facility", - "ventilation_space_type_name": "public_assembly_spaces_religious_workshop", - "electric_equipment_space_type_name": "fellowship hall - religious facility" - }, - { - "space_type_name": "worship/pulpit/choir area", - "lighting_space_type_name": "worship_pulpit_choir_area", - "ventilation_space_type_name": "public_assembly_spaces_religious_workshop", - "electric_equipment_space_type_name": "worship/pulpit/choir area" - }, - { - "space_type_name": "restroom - all other", - "lighting_space_type_name": "restroom_all_other", - "ventilation_space_type_name": null, - "electric_equipment_space_type_name": "restroom - all other" - }, - { - "space_type_name": "restroom - visually impaired", - "lighting_space_type_name": "restroom_visually_impaired", - "ventilation_space_type_name": null, - "electric_equipment_space_type_name": null + "space_type_name": "physical therapy", + "lighting_space_type_name": "physical_therapy_lighting", + "ventilation_space_type_name": "physical_therapy_ventilation", + "electric_equipment_space_type_name": "physical_therapy_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "physical_therapy" }, { - "space_type_name": "retail dressing room", - "lighting_space_type_name": "retail_dressing_room", - "ventilation_space_type_name": "retail_mall_common_areas", - "electric_equipment_space_type_name": null + "space_type_name": "playing area", + "lighting_space_type_name": "playing_area_lighting", + "ventilation_space_type_name": "playing_area_ventilation", + "electric_equipment_space_type_name": "gymnasium_playing_area_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "gymnasium_playing_area" }, { - "space_type_name": "retail mall concourse", - "lighting_space_type_name": "retail_mall_concourse", - "ventilation_space_type_name": "retail_mall_common_areas", - "electric_equipment_space_type_name": null + "space_type_name": "plenum", + "lighting_space_type_name": "none_lighting", + "ventilation_space_type_name": "plenum_ventilation", + "electric_equipment_space_type_name": "plenum_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "plenum" }, { - "space_type_name": "seating area, general", - "lighting_space_type_name": "seating_area_general", - "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", - "electric_equipment_space_type_name": "seating area, general" + "space_type_name": "post office", + "lighting_space_type_name": "post_office_lighting", + "ventilation_space_type_name": "post_office_ventilation", + "electric_equipment_space_type_name": "post_office_sorting_area_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "post_office_sorting_area" }, { - "space_type_name": "sports arena playing area, class I", - "lighting_space_type_name": "sports_arena_playing_area_class_I", - "ventilation_space_type_name": "sports_entertainment_sports_arena", - "electric_equipment_space_type_name": null + "space_type_name": "recovery", + "lighting_space_type_name": "recovery_lighting", + "ventilation_space_type_name": "recovery_ventilation", + "electric_equipment_space_type_name": "patient_room_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "patient_room" }, { - "space_type_name": "sports arena playing area, class II", - "lighting_space_type_name": "sports_arena_playing_area_class_II", - "ventilation_space_type_name": "sports_entertainment_sports_arena", - "electric_equipment_space_type_name": "sports arena playing area, class II" + "space_type_name": "recreation/common living", + "lighting_space_type_name": "recreation_common_living_lighting", + "ventilation_space_type_name": "recreation_common_living_ventilation", + "electric_equipment_space_type_name": "lounge_breakroom_all_other_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "lounge_breakroom_all_other" }, { - "space_type_name": "sports arena playing area, class III", - "lighting_space_type_name": "sports_arena_playing_area_class_III", - "ventilation_space_type_name": "sports_entertainment_sports_arena", - "electric_equipment_space_type_name": null + "space_type_name": "restroom", + "lighting_space_type_name": "restroom_lighting", + "ventilation_space_type_name": "restroom_ventilation", + "electric_equipment_space_type_name": "restroom_all_other_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "restroom_all_other" }, { - "space_type_name": "sports arena playing area, class IV", - "lighting_space_type_name": "sports_arena_playing_area_class_IV", - "ventilation_space_type_name": "sports_entertainment_sports_arena", - "electric_equipment_space_type_name": "sports arena playing area, class IV" + "space_type_name": "retail", + "lighting_space_type_name": "retail_sales_lighting", + "ventilation_space_type_name": "retail_sales_ventilation", + "electric_equipment_space_type_name": "sales_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "sales" }, { - "space_type_name": "sports arena - ring sports area", - "lighting_space_type_name": "sports_arena_ring_sports_area", - "ventilation_space_type_name": "sports_entertainment_sports_arena", - "electric_equipment_space_type_name": null + "space_type_name": "shaft", + "lighting_space_type_name": "none_lighting", + "ventilation_space_type_name": "shaft_ventilation", + "electric_equipment_space_type_name": "shaft_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "shaft" }, { - "space_type_name": "sports arena - court sports area", - "lighting_space_type_name": "sports_arena_court_sports_area", - "ventilation_space_type_name": "sports_entertainment_sports_arena", - "electric_equipment_space_type_name": null + "space_type_name": "sleeping quarters", + "lighting_space_type_name": "sleeping_quarters_lighting", + "ventilation_space_type_name": "sleeping_quarters_ventilation", + "electric_equipment_space_type_name": "firestation_sleeping_quarters_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "firestation_sleeping_quarters" }, { - "space_type_name": "sports arena - indoor playing field", - "lighting_space_type_name": "sports_arena_indoor_playing_field", - "ventilation_space_type_name": "sports_entertainment_sports_arena", - "electric_equipment_space_type_name": null + "space_type_name": "sports arena", + "lighting_space_type_name": "sports_arena_lighting", + "ventilation_space_type_name": "sports_arena_ventilation", + "electric_equipment_space_type_name": "sports_arena_playing_area_class_ii_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "sports_arena_playing_area_class_ii" }, { "space_type_name": "stairwell", - "lighting_space_type_name": "stairwell", - "ventilation_space_type_name": "general_conference_corridors", - "electric_equipment_space_type_name": "stairwell" - }, - { - "space_type_name": "storage < 50 sf - all other", - "lighting_space_type_name": "storage_ all_other_small", - "ventilation_space_type_name": "general_conference_storage_rooms", - "electric_equipment_space_type_name": "storage < 50 sf - all other" + "lighting_space_type_name": "stairwell_lighting", + "ventilation_space_type_name": "stairwell_ventilation", + "electric_equipment_space_type_name": "stairwell_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "stairwell" }, { - "space_type_name": "storage 50 to 1000 sf - all other", - "lighting_space_type_name": "storage_ all_other_large", - "ventilation_space_type_name": "general_conference_storage_rooms", - "electric_equipment_space_type_name": "storage 50 to 1000 sf - all other" + "space_type_name": "storage", + "lighting_space_type_name": "storage_lighting", + "ventilation_space_type_name": "storage_ventilation", + "electric_equipment_space_type_name": "storage_50_to_1000_sf_all_other_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "storage_50_to_1000_sf_all_other" }, { - "space_type_name": "storage < 50 sf - hospital", - "lighting_space_type_name": "storage_hospital_small", - "ventilation_space_type_name": "general_conference_storage_rooms", - "electric_equipment_space_type_name": "storage < 50 sf - hospital" - }, - { - "space_type_name": "storage 50 to 1000 sf - hospital", - "lighting_space_type_name": "storage_hospital_large", - "ventilation_space_type_name": "general_conference_storage_rooms", - "electric_equipment_space_type_name": "storage 50 to 1000 sf - hospital" - }, - { - "space_type_name": "storage - inactive", - "lighting_space_type_name": "storage_inactive", - "ventilation_space_type_name": "general_conference_storage_rooms", - "electric_equipment_space_type_name": "storage - inactive" - }, - { - "space_type_name": "storage, inactive - museum", - "lighting_space_type_name": "storage_inactive_museum", - "ventilation_space_type_name": "general_conference_storage_rooms", - "electric_equipment_space_type_name": null - }, - { - "space_type_name": "airport concourse", - "lighting_space_type_name": "airport_concourse", - "ventilation_space_type_name": "office_buildings_reception_areas", - "electric_equipment_space_type_name": "airport concourse" - }, - { - "space_type_name": "baggage/carousel", - "lighting_space_type_name": "baggage_carousel", - "ventilation_space_type_name": "office_buildings_reception_areas", - "electric_equipment_space_type_name": "baggage/carousel" - }, - { - "space_type_name": "transportation ticket counter", - "lighting_space_type_name": "transportation_ticket_counter", - "ventilation_space_type_name": "office_buildings_reception_areas", - "electric_equipment_space_type_name": "transportation ticket counter" + "space_type_name": "transportation", + "lighting_space_type_name": "transportation_lighting", + "ventilation_space_type_name": "transportation_ventilation", + "electric_equipment_space_type_name": "transportation_ticket_counter_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "transportation_ticket_counter" }, { "space_type_name": "vehicular maintenance", - "lighting_space_type_name": "vehicular_maintenance", - "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", - "electric_equipment_space_type_name": "vehicular maintenance" - }, - { - "space_type_name": "warehouse - bulk storage", - "lighting_space_type_name": "warehouse_bulk_storage", - "ventilation_space_type_name": "miscellaneous_spaces_warehouses", - "electric_equipment_space_type_name": "warehouse - bulk storage" - }, - { - "space_type_name": "warehouse - fine storage", - "lighting_space_type_name": "warehouse_fine_storage", - "ventilation_space_type_name": "miscellaneous_spaces_warehouses", - "electric_equipment_space_type_name": "warehouse - fine storage" + "lighting_space_type_name": "vehicular_maintenance_lighting", + "ventilation_space_type_name": "vehicular_maintenance_ventilation", + "electric_equipment_space_type_name": "vehicular_maintenance_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "vehicular_maintenance" }, { "space_type_name": "workshop", - "lighting_space_type_name": "workshop", - "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", - "electric_equipment_space_type_name": "workshop" - }, - { - "space_type_name": "sales", - "lighting_space_type_name": "sales", - "ventilation_space_type_name": "retail_sales", - "electric_equipment_space_type_name": "sales" - }, - { - "space_type_name": "sales - display type 1", - "lighting_space_type_name": "sales_display_type_1", - "ventilation_space_type_name": "retail_sales", - "electric_equipment_space_type_name": null - }, - { - "space_type_name": "sales - display type 2", - "lighting_space_type_name": "sales_display_type_2", - "ventilation_space_type_name": "retail_sales", - "electric_equipment_space_type_name": null - }, - { - "space_type_name": "sales - display type 3", - "lighting_space_type_name": "sales_display_type_3", - "ventilation_space_type_name": "retail_sales", - "electric_equipment_space_type_name": null - }, - { - "space_type_name": "sales - display type 4", - "lighting_space_type_name": "sales_display_type_4", - "ventilation_space_type_name": "retail_sales", - "electric_equipment_space_type_name": null - }, - { - "space_type_name": "guest room - highway", - "lighting_space_type_name": "guest_room", - "ventilation_space_type_name": "hotels_motels_resorts_dormitories_barracks_sleeping_areas", - "electric_equipment_space_type_name": null - }, - { - "space_type_name": "lodging dining - highway", - "lighting_space_type_name": "dining_general", - "ventilation_space_type_name": "food_beverage_service_restaurant_dining_rooms", - "electric_equipment_space_type_name": null - }, - { - "space_type_name": "audience seating - classroom/lecture/training", - "lighting_space_type_name": "audience_seating_general", - "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", - "electric_equipment_space_type_name": null - }, - { - "space_type_name": "audience seating - conference/meeting/multipurpose", - "lighting_space_type_name": "audience_seating_general", - "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", - "electric_equipment_space_type_name": null - }, - { - "space_type_name": "audience seating - corridor/transition", - "lighting_space_type_name": "audience_seating_general", - "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", - "electric_equipment_space_type_name": null - }, - { - "space_type_name": "guest room - bathroom", - "lighting_space_type_name": "guest_room", - "ventilation_space_type_name": "hotels_motels_resorts_dormitories_barracks_sleeping_areas", - "electric_equipment_space_type_name": null + "lighting_space_type_name": "workshop_lighting", + "ventilation_space_type_name": "workshop_ventilation", + "electric_equipment_space_type_name": "workshop_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "workshop" + }, + { + "space_type_name": "worship", + "lighting_space_type_name": "worship_lighting", + "ventilation_space_type_name": "worship_ventilation", + "electric_equipment_space_type_name": "worship_pulpit_choir_area_electric_equipment", + "natural_gas_equipment_space_type_name": null, + "schedule_set_name": "worship_pulpit_choir_area" } ] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/level_2_electric_equipment.csv b/data/openstudio_standards_data/database_files/level_2_electric_equipment.csv index 5a49077ef2..cf99d4dcea 100644 --- a/data/openstudio_standards_data/database_files/level_2_electric_equipment.csv +++ b/data/openstudio_standards_data/database_files/level_2_electric_equipment.csv @@ -1,91 +1,94 @@ electric_equipment_space_type_name,electric_equipment_minimum_epd,electric_equipment_average_epd,electric_equipment_median_epd,electric_equipment_maximum_epd,electric_equipment_epd_unit -corridor - all other,0,0.28,0.24,0.82,W/ft2 -dining - all other,0.32,0.55,0.55,0.82,W/ft2 -electrical/mechanical,0,0,0,0,W/ft2 -kitchen,0.3,0.76,0.71,2.52,W/ft2 -laboratory,0.49,0.78,0.7,2.02,W/ft2 -lobby - all other,0.16,0.41,0.35,0.83,W/ft2 -locker room,0,0.38,0.44,0.97,W/ft2 -lounge/breakroom - all other,0,0.49,0.52,0.88,W/ft2 -office - enclosed <= 250 sf,0.51,0.68,0.68,0.89,W/ft2 -office - enclosed > 250 sf,0.65,0.7,0.69,0.82,W/ft2 -office - open,0.53,0.66,0.67,0.81,W/ft2 -restroom - all other,0,0,0,0,W/ft2 -stairwell,0,0.25,0.25,0.53,W/ft2 -storage < 50 sf - all other,0,0,0,0,W/ft2 -storage 50 to 1000 sf - all other,0,0,0,0,W/ft2 -vehicular maintenance,0.65,0.69,0.69,0.73,W/ft2 -workshop,0,0.54,0.57,0.74,W/ft2 -atrium - first three floors,0,0.52,0.54,0.75,W/ft2 -audience seating - convention center,0.63,0.63,0.63,0.63,W/ft2 -classroom/lecture/training - all other,0.5,0.63,0.62,0.8,W/ft2 -conference/meeting/multipurpose,0.42,0.62,0.62,0.97,W/ft2 -exhibit - convention center,0.84,0.84,0.84,0.84,W/ft2 -gymnasium exercise area,0.27,0.48,0.49,0.68,W/ft2 -gymnasium playing area,0,0.51,0.51,1.06,W/ft2 -laundry/washing,0,0.39,0.39,0.59,W/ft2 -lobby - elevator,0.32,0.32,0.32,0.32,W/ft2 -nurses station,0,0.52,0.57,0.85,W/ft2 -post office - sorting area,0,0.23,0.24,0.39,W/ft2 -sales,0.41,0.67,0.67,0.92,W/ft2 -"sports arena playing area, class IV",0.32,0.5,0.64,0.69,W/ft2 -audience seating - all other,0.31,0.49,0.46,0.75,W/ft2 -confinement cells,0.22,0.26,0.26,0.32,W/ft2 -courtroom,0.25,0.4,0.4,0.56,W/ft2 -judges chambers,0.5,0.59,0.59,0.68,W/ft2 -library - stacks,0,0.2,0.2,0.33,W/ft2 -storage - inactive,0,0,0,0,W/ft2 -dining - bar/lounge/leisure,0.5,0.5,0.5,0.5,W/ft2 -dining - cafeteria/fast food,0.6,0.6,0.6,0.6,W/ft2 -dining - family,0.78,0.78,0.78,0.78,W/ft2 -computer room,0.69,0.7,0.69,0.73,W/ft2 -dormitory - living quarters,0.23,0.44,0.42,0.62,W/ft2 -audience seating - exercise center,0.6,0.6,0.6,0.6,W/ft2 -exam/treatment,0.51,0.56,0.53,0.66,W/ft2 -library - reading,0.32,0.49,0.46,0.71,W/ft2 -emergency vehicle garage,0.39,0.39,0.39,0.39,W/ft2 -firestation - sleeping quarters,0.37,0.37,0.37,0.37,W/ft2 -"parking area, interior",0.11,0.27,0.3,0.32,W/ft2 -audience seating - gymnasium,0.64,0.64,0.64,0.64,W/ft2 -emergency room,0.61,0.62,0.62,0.62,W/ft2 -patient room,0.71,0.72,0.72,0.73,W/ft2 -pharmacy,0.47,0.64,0.72,0.74,W/ft2 -corridor - hospital,0.3,0.3,0.3,0.3,W/ft2 -fellowship hall - religious facility,0.36,0.39,0.39,0.41,W/ft2 -lounge/breakroom - healthcare facility,0.75,0.75,0.75,0.75,W/ft2 -operating room,0.77,0.77,0.77,0.77,W/ft2 -physical therapy,0.73,0.73,0.73,0.73,W/ft2 -storage < 50 sf - hospital,0,0,0,0,W/ft2 -storage 50 to 1000 sf - hospital,0,0,0,0,W/ft2 -guest room,0.47,0.53,0.53,0.58,W/ft2 -lobby - hotel,0.5,0.5,0.5,0.5,W/ft2 -library - cataloging,0.21,0.21,0.21,0.21,W/ft2 -museum exhibit area,0.32,0.46,0.43,0.68,W/ft2 -corridor - manufacturing facility,0.38,0.38,0.38,0.38,W/ft2 -manufacturing equipment room,0,0,0,0,W/ft2 -manufacturing low bay,0.67,0.67,0.67,0.67,W/ft2 -performing arts dressing room,0.29,0.41,0.43,0.5,W/ft2 -audience seating - auditorium,0.26,0.29,0.29,0.32,W/ft2 -audience seating - motion picture theater,0.28,0.28,0.28,0.28,W/ft2 -lobby - motion picture theater,0.33,0.33,0.33,0.33,W/ft2 -Dwelling Unit,0.25,0.25,0.25,0.25,W/ft2 -museum restoration,0.21,0.21,0.21,0.21,W/ft2 -banking activity,0.54,0.55,0.55,0.56,W/ft2 -warehouse - fine storage,0,0.06,0.06,0.12,W/ft2 -classroom/lecture/training - penitentiary,0.41,0.41,0.41,0.41,W/ft2 -dining - penitentiary,0.35,0.35,0.35,0.35,W/ft2 -audience seating - performing arts theater,0.27,0.27,0.27,0.27,W/ft2 -lobby - performing arts theater,0.33,0.33,0.33,0.33,W/ft2 -audience seating - religious facility,0.41,0.41,0.41,0.41,W/ft2 -worship/pulpit/choir area,0.42,0.42,0.42,0.42,W/ft2 -classroom/lecture/training - preschool to 12th,0.67,0.67,0.67,0.67,W/ft2 -"sports arena playing area, class II",0.32,0.48,0.48,0.64,W/ft2 -audience seating - sports arena,0.38,0.38,0.38,0.38,W/ft2 -airport concourse,0.52,0.52,0.52,0.52,W/ft2 -atrium < 20 ft height,0.53,0.53,0.53,0.53,W/ft2 -atrium > 40 ft height,0.53,0.53,0.53,0.53,W/ft2 -atrium >= 20 ft and <= 40 ft in height,0.53,0.53,0.53,0.53,W/ft2 -baggage/carousel,0.55,0.55,0.55,0.55,W/ft2 -"seating area, general",0.25,0.25,0.25,0.25,W/ft2 -transportation ticket counter,0.74,0.74,0.74,0.74,W/ft2 -warehouse - bulk storage,0.11,0.11,0.11,0.11,W/ft2 +corridor_all_other_electric_equipment,0,0.28,0.24,0.82,W/ft2 +dining_all_other_electric_equipment,0.32,0.55,0.55,0.82,W/ft2 +electrical_mechanical_electric_equipment,0,0,0,0,W/ft2 +kitchen_electric_equipment,0.3,0.76,0.71,2.52,W/ft2 +laboratory_electric_equipment,0.49,0.78,0.7,2.02,W/ft2 +lobby_all_other_electric_equipment,0.16,0.41,0.35,0.83,W/ft2 +locker_room_electric_equipment,0,0.38,0.44,0.97,W/ft2 +lounge_breakroom_all_other_electric_equipment,0,0.49,0.52,0.88,W/ft2 +office_enclosed_lte_250_sf_electric_equipment,0.51,0.68,0.68,0.89,W/ft2 +office_enclosed_gt_250_sf_electric_equipment,0.65,0.7,0.69,0.82,W/ft2 +office_open_electric_equipment,0.53,0.66,0.67,0.81,W/ft2 +restroom_all_other_electric_equipment,0,0,0,0,W/ft2 +stairwell_electric_equipment,0,0.25,0.25,0.53,W/ft2 +storage_lt_50_sf_all_other_electric_equipment,0,0,0,0,W/ft2 +storage_50_to_1000_sf_all_other_electric_equipment,0,0,0,0,W/ft2 +vehicular_maintenance_electric_equipment,0.65,0.69,0.69,0.73,W/ft2 +workshop_electric_equipment,0,0.54,0.57,0.74,W/ft2 +atrium_first_three_floors_electric_equipment,0,0.52,0.54,0.75,W/ft2 +audience_seating_convention_center_electric_equipment,0.63,0.63,0.63,0.63,W/ft2 +classroom_lecture_training_all_other_electric_equipment,0.5,0.63,0.62,0.8,W/ft2 +conference_meeting_multipurpose_electric_equipment,0.42,0.62,0.62,0.97,W/ft2 +exhibit_convention_center_electric_equipment,0.84,0.84,0.84,0.84,W/ft2 +gymnasium_exercise_area_electric_equipment,0.27,0.48,0.49,0.68,W/ft2 +gymnasium_playing_area_electric_equipment,0,0.51,0.51,1.06,W/ft2 +laundry_washing_electric_equipment,0,0.39,0.39,0.59,W/ft2 +lobby_elevator_electric_equipment,0.32,0.32,0.32,0.32,W/ft2 +nurses_station_electric_equipment,0,0.52,0.57,0.85,W/ft2 +post_office_sorting_area_electric_equipment,0,0.23,0.24,0.39,W/ft2 +sales_electric_equipment,0.41,0.67,0.67,0.92,W/ft2 +sports_arena_playing_area_class_iv_electric_equipment,0.32,0.5,0.64,0.69,W/ft2 +audience_seating_all_other_electric_equipment,0.31,0.49,0.46,0.75,W/ft2 +confinement_cells_electric_equipment,0.22,0.26,0.26,0.32,W/ft2 +courtroom_electric_equipment,0.25,0.4,0.4,0.56,W/ft2 +judges_chambers_electric_equipment,0.5,0.59,0.59,0.68,W/ft2 +library_stacks_electric_equipment,0,0.2,0.2,0.33,W/ft2 +storage_inactive_electric_equipment,0,0,0,0,W/ft2 +dining_bar_lounge_leisure_electric_equipment,0.5,0.5,0.5,0.5,W/ft2 +dining_cafeteria_fast_food_electric_equipment,0.6,0.6,0.6,0.6,W/ft2 +dining_family_electric_equipment,0.78,0.78,0.78,0.78,W/ft2 +computer_room_electric_equipment,0.69,0.7,0.69,0.73,W/ft2 +dormitory_living_quarters_electric_equipment,0.23,0.44,0.42,0.62,W/ft2 +audience_seating_exercise_center_electric_equipment,0.6,0.6,0.6,0.6,W/ft2 +exam_treatment_electric_equipment,0.51,0.56,0.53,0.66,W/ft2 +library_reading_electric_equipment,0.32,0.49,0.46,0.71,W/ft2 +emergency_vehicle_garage_electric_equipment,0.39,0.39,0.39,0.39,W/ft2 +firestation_sleeping_quarters_electric_equipment,0.37,0.37,0.37,0.37,W/ft2 +parking_area_interior_electric_equipment,0.11,0.27,0.3,0.32,W/ft2 +audience_seating_gymnasium_electric_equipment,0.64,0.64,0.64,0.64,W/ft2 +emergency_room_electric_equipment,0.61,0.62,0.62,0.62,W/ft2 +patient_room_electric_equipment,0.71,0.72,0.72,0.73,W/ft2 +pharmacy_electric_equipment,0.47,0.64,0.72,0.74,W/ft2 +corridor_hospital_electric_equipment,0.3,0.3,0.3,0.3,W/ft2 +fellowship_hall_religious_facility_electric_equipment,0.36,0.39,0.39,0.41,W/ft2 +lounge_breakroom_healthcare_facility_electric_equipment,0.75,0.75,0.75,0.75,W/ft2 +operating_room_electric_equipment,0.77,0.77,0.77,0.77,W/ft2 +physical_therapy_electric_equipment,0.73,0.73,0.73,0.73,W/ft2 +storage_lt_50_sf_hospital_electric_equipment,0,0,0,0,W/ft2 +storage_50_to_1000_sf_hospital_electric_equipment,0,0,0,0,W/ft2 +guest_room_electric_equipment,0.47,0.53,0.53,0.58,W/ft2 +lobby_hotel_electric_equipment,0.5,0.5,0.5,0.5,W/ft2 +library_cataloging_electric_equipment,0.21,0.21,0.21,0.21,W/ft2 +museum_exhibit_area_electric_equipment,0.32,0.46,0.43,0.68,W/ft2 +corridor_manufacturing_facility_electric_equipment,0.38,0.38,0.38,0.38,W/ft2 +manufacturing_equipment_room_electric_equipment,0,0,0,0,W/ft2 +manufacturing_low_bay_electric_equipment,0.67,0.67,0.67,0.67,W/ft2 +performing_arts_dressing_room_electric_equipment,0.29,0.41,0.43,0.5,W/ft2 +audience_seating_auditorium_electric_equipment,0.26,0.29,0.29,0.32,W/ft2 +audience_seating_motion_picture_theater_electric_equipment,0.28,0.28,0.28,0.28,W/ft2 +lobby_motion_picture_theater_electric_equipment,0.33,0.33,0.33,0.33,W/ft2 +dwelling_unit_electric_equipment,0.25,0.25,0.25,0.25,W/ft2 +museum_restoration_electric_equipment,0.21,0.21,0.21,0.21,W/ft2 +banking_activity_electric_equipment,0.54,0.55,0.55,0.56,W/ft2 +warehouse_fine_storage_electric_equipment,0,0.06,0.06,0.12,W/ft2 +classroom_lecture_training_penitentiary_electric_equipment,0.41,0.41,0.41,0.41,W/ft2 +dining_penitentiary_electric_equipment,0.35,0.35,0.35,0.35,W/ft2 +audience_seating_performing_arts_theater_electric_equipment,0.27,0.27,0.27,0.27,W/ft2 +lobby_performing_arts_theater_electric_equipment,0.33,0.33,0.33,0.33,W/ft2 +audience_seating_religious_facility_electric_equipment,0.41,0.41,0.41,0.41,W/ft2 +worship_pulpit_choir_area_electric_equipment,0.42,0.42,0.42,0.42,W/ft2 +classroom_lecture_training_preschool_to_12th_electric_equipment,0.67,0.67,0.67,0.67,W/ft2 +sports_arena_playing_area_class_ii_electric_equipment,0.32,0.48,0.48,0.64,W/ft2 +audience_seating_sports_arena_electric_equipment,0.38,0.38,0.38,0.38,W/ft2 +airport_concourse_electric_equipment,0.52,0.52,0.52,0.52,W/ft2 +atrium_lt_20_ft_height_electric_equipment,0.53,0.53,0.53,0.53,W/ft2 +atrium_gt_40_ft_height_electric_equipment,0.53,0.53,0.53,0.53,W/ft2 +atrium_gte_20_ft_and_lte_40_ft_in_height_electric_equipment,0.53,0.53,0.53,0.53,W/ft2 +baggage_carousel_electric_equipment,0.55,0.55,0.55,0.55,W/ft2 +seating_area_general_electric_equipment,0.25,0.25,0.25,0.25,W/ft2 +transportation_ticket_counter_electric_equipment,0.74,0.74,0.74,0.74,W/ft2 +warehouse_bulk_storage_electric_equipment,0.11,0.11,0.11,0.11,W/ft2 +attic_electric_equipment,0,0,0,0,W/ft2 +plenum_electric_equipment,0,0,0,0,W/ft2 +shaft_electric_equipment,0,0,0,0,W/ft2 diff --git a/data/openstudio_standards_data/database_files/level_2_electric_equipment.json b/data/openstudio_standards_data/database_files/level_2_electric_equipment.json index 48082959b2..04fff2fb37 100644 --- a/data/openstudio_standards_data/database_files/level_2_electric_equipment.json +++ b/data/openstudio_standards_data/database_files/level_2_electric_equipment.json @@ -1,6 +1,6 @@ [ { - "electric_equipment_space_type_name": "corridor - all other", + "electric_equipment_space_type_name": "corridor_all_other_electric_equipment", "electric_equipment_minimum_epd": 0, "electric_equipment_average_epd": 0.28, "electric_equipment_median_epd": 0.24, @@ -8,7 +8,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "dining - all other", + "electric_equipment_space_type_name": "dining_all_other_electric_equipment", "electric_equipment_minimum_epd": 0.32, "electric_equipment_average_epd": 0.55, "electric_equipment_median_epd": 0.55, @@ -16,7 +16,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "electrical/mechanical", + "electric_equipment_space_type_name": "electrical_mechanical_electric_equipment", "electric_equipment_minimum_epd": 0, "electric_equipment_average_epd": 0, "electric_equipment_median_epd": 0, @@ -24,7 +24,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "kitchen", + "electric_equipment_space_type_name": "kitchen_electric_equipment", "electric_equipment_minimum_epd": 0.3, "electric_equipment_average_epd": 0.76, "electric_equipment_median_epd": 0.71, @@ -32,7 +32,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "laboratory", + "electric_equipment_space_type_name": "laboratory_electric_equipment", "electric_equipment_minimum_epd": 0.49, "electric_equipment_average_epd": 0.78, "electric_equipment_median_epd": 0.7, @@ -40,7 +40,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "lobby - all other", + "electric_equipment_space_type_name": "lobby_all_other_electric_equipment", "electric_equipment_minimum_epd": 0.16, "electric_equipment_average_epd": 0.41, "electric_equipment_median_epd": 0.35, @@ -48,7 +48,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "locker room", + "electric_equipment_space_type_name": "locker_room_electric_equipment", "electric_equipment_minimum_epd": 0, "electric_equipment_average_epd": 0.38, "electric_equipment_median_epd": 0.44, @@ -56,7 +56,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "lounge/breakroom - all other", + "electric_equipment_space_type_name": "lounge_breakroom_all_other_electric_equipment", "electric_equipment_minimum_epd": 0, "electric_equipment_average_epd": 0.49, "electric_equipment_median_epd": 0.52, @@ -64,7 +64,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "office - enclosed <= 250 sf", + "electric_equipment_space_type_name": "office_enclosed_lte_250_sf_electric_equipment", "electric_equipment_minimum_epd": 0.51, "electric_equipment_average_epd": 0.68, "electric_equipment_median_epd": 0.68, @@ -72,7 +72,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "office - enclosed > 250 sf", + "electric_equipment_space_type_name": "office_enclosed_gt_250_sf_electric_equipment", "electric_equipment_minimum_epd": 0.65, "electric_equipment_average_epd": 0.7, "electric_equipment_median_epd": 0.69, @@ -80,7 +80,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "office - open", + "electric_equipment_space_type_name": "office_open_electric_equipment", "electric_equipment_minimum_epd": 0.53, "electric_equipment_average_epd": 0.66, "electric_equipment_median_epd": 0.67, @@ -88,7 +88,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "restroom - all other", + "electric_equipment_space_type_name": "restroom_all_other_electric_equipment", "electric_equipment_minimum_epd": 0, "electric_equipment_average_epd": 0, "electric_equipment_median_epd": 0, @@ -96,7 +96,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "stairwell", + "electric_equipment_space_type_name": "stairwell_electric_equipment", "electric_equipment_minimum_epd": 0, "electric_equipment_average_epd": 0.25, "electric_equipment_median_epd": 0.25, @@ -104,7 +104,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "storage < 50 sf - all other", + "electric_equipment_space_type_name": "storage_lt_50_sf_all_other_electric_equipment", "electric_equipment_minimum_epd": 0, "electric_equipment_average_epd": 0, "electric_equipment_median_epd": 0, @@ -112,7 +112,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "storage 50 to 1000 sf - all other", + "electric_equipment_space_type_name": "storage_50_to_1000_sf_all_other_electric_equipment", "electric_equipment_minimum_epd": 0, "electric_equipment_average_epd": 0, "electric_equipment_median_epd": 0, @@ -120,7 +120,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "vehicular maintenance", + "electric_equipment_space_type_name": "vehicular_maintenance_electric_equipment", "electric_equipment_minimum_epd": 0.65, "electric_equipment_average_epd": 0.69, "electric_equipment_median_epd": 0.69, @@ -128,7 +128,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "workshop", + "electric_equipment_space_type_name": "workshop_electric_equipment", "electric_equipment_minimum_epd": 0, "electric_equipment_average_epd": 0.54, "electric_equipment_median_epd": 0.57, @@ -136,7 +136,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "atrium - first three floors", + "electric_equipment_space_type_name": "atrium_first_three_floors_electric_equipment", "electric_equipment_minimum_epd": 0, "electric_equipment_average_epd": 0.52, "electric_equipment_median_epd": 0.54, @@ -144,7 +144,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "audience seating - convention center", + "electric_equipment_space_type_name": "audience_seating_convention_center_electric_equipment", "electric_equipment_minimum_epd": 0.63, "electric_equipment_average_epd": 0.63, "electric_equipment_median_epd": 0.63, @@ -152,7 +152,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "classroom/lecture/training - all other", + "electric_equipment_space_type_name": "classroom_lecture_training_all_other_electric_equipment", "electric_equipment_minimum_epd": 0.5, "electric_equipment_average_epd": 0.63, "electric_equipment_median_epd": 0.62, @@ -160,7 +160,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "conference/meeting/multipurpose", + "electric_equipment_space_type_name": "conference_meeting_multipurpose_electric_equipment", "electric_equipment_minimum_epd": 0.42, "electric_equipment_average_epd": 0.62, "electric_equipment_median_epd": 0.62, @@ -168,7 +168,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "exhibit - convention center", + "electric_equipment_space_type_name": "exhibit_convention_center_electric_equipment", "electric_equipment_minimum_epd": 0.84, "electric_equipment_average_epd": 0.84, "electric_equipment_median_epd": 0.84, @@ -176,7 +176,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "gymnasium exercise area", + "electric_equipment_space_type_name": "gymnasium_exercise_area_electric_equipment", "electric_equipment_minimum_epd": 0.27, "electric_equipment_average_epd": 0.48, "electric_equipment_median_epd": 0.49, @@ -184,7 +184,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "gymnasium playing area", + "electric_equipment_space_type_name": "gymnasium_playing_area_electric_equipment", "electric_equipment_minimum_epd": 0, "electric_equipment_average_epd": 0.51, "electric_equipment_median_epd": 0.51, @@ -192,7 +192,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "laundry/washing", + "electric_equipment_space_type_name": "laundry_washing_electric_equipment", "electric_equipment_minimum_epd": 0, "electric_equipment_average_epd": 0.39, "electric_equipment_median_epd": 0.39, @@ -200,7 +200,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "lobby - elevator", + "electric_equipment_space_type_name": "lobby_elevator_electric_equipment", "electric_equipment_minimum_epd": 0.32, "electric_equipment_average_epd": 0.32, "electric_equipment_median_epd": 0.32, @@ -208,7 +208,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "nurses station", + "electric_equipment_space_type_name": "nurses_station_electric_equipment", "electric_equipment_minimum_epd": 0, "electric_equipment_average_epd": 0.52, "electric_equipment_median_epd": 0.57, @@ -216,7 +216,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "post office - sorting area", + "electric_equipment_space_type_name": "post_office_sorting_area_electric_equipment", "electric_equipment_minimum_epd": 0, "electric_equipment_average_epd": 0.23, "electric_equipment_median_epd": 0.24, @@ -224,7 +224,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "sales", + "electric_equipment_space_type_name": "sales_electric_equipment", "electric_equipment_minimum_epd": 0.41, "electric_equipment_average_epd": 0.67, "electric_equipment_median_epd": 0.67, @@ -232,7 +232,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "sports arena playing area, class IV", + "electric_equipment_space_type_name": "sports_arena_playing_area_class_iv_electric_equipment", "electric_equipment_minimum_epd": 0.32, "electric_equipment_average_epd": 0.5, "electric_equipment_median_epd": 0.64, @@ -240,7 +240,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "audience seating - all other", + "electric_equipment_space_type_name": "audience_seating_all_other_electric_equipment", "electric_equipment_minimum_epd": 0.31, "electric_equipment_average_epd": 0.49, "electric_equipment_median_epd": 0.46, @@ -248,7 +248,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "confinement cells", + "electric_equipment_space_type_name": "confinement_cells_electric_equipment", "electric_equipment_minimum_epd": 0.22, "electric_equipment_average_epd": 0.26, "electric_equipment_median_epd": 0.26, @@ -256,7 +256,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "courtroom", + "electric_equipment_space_type_name": "courtroom_electric_equipment", "electric_equipment_minimum_epd": 0.25, "electric_equipment_average_epd": 0.4, "electric_equipment_median_epd": 0.4, @@ -264,7 +264,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "judges chambers", + "electric_equipment_space_type_name": "judges_chambers_electric_equipment", "electric_equipment_minimum_epd": 0.5, "electric_equipment_average_epd": 0.59, "electric_equipment_median_epd": 0.59, @@ -272,7 +272,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "library - stacks", + "electric_equipment_space_type_name": "library_stacks_electric_equipment", "electric_equipment_minimum_epd": 0, "electric_equipment_average_epd": 0.2, "electric_equipment_median_epd": 0.2, @@ -280,7 +280,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "storage - inactive", + "electric_equipment_space_type_name": "storage_inactive_electric_equipment", "electric_equipment_minimum_epd": 0, "electric_equipment_average_epd": 0, "electric_equipment_median_epd": 0, @@ -288,7 +288,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "dining - bar/lounge/leisure", + "electric_equipment_space_type_name": "dining_bar_lounge_leisure_electric_equipment", "electric_equipment_minimum_epd": 0.5, "electric_equipment_average_epd": 0.5, "electric_equipment_median_epd": 0.5, @@ -296,7 +296,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "dining - cafeteria/fast food", + "electric_equipment_space_type_name": "dining_cafeteria_fast_food_electric_equipment", "electric_equipment_minimum_epd": 0.6, "electric_equipment_average_epd": 0.6, "electric_equipment_median_epd": 0.6, @@ -304,7 +304,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "dining - family", + "electric_equipment_space_type_name": "dining_family_electric_equipment", "electric_equipment_minimum_epd": 0.78, "electric_equipment_average_epd": 0.78, "electric_equipment_median_epd": 0.78, @@ -312,7 +312,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "computer room", + "electric_equipment_space_type_name": "computer_room_electric_equipment", "electric_equipment_minimum_epd": 0.69, "electric_equipment_average_epd": 0.7, "electric_equipment_median_epd": 0.69, @@ -320,7 +320,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "dormitory - living quarters", + "electric_equipment_space_type_name": "dormitory_living_quarters_electric_equipment", "electric_equipment_minimum_epd": 0.23, "electric_equipment_average_epd": 0.44, "electric_equipment_median_epd": 0.42, @@ -328,7 +328,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "audience seating - exercise center", + "electric_equipment_space_type_name": "audience_seating_exercise_center_electric_equipment", "electric_equipment_minimum_epd": 0.6, "electric_equipment_average_epd": 0.6, "electric_equipment_median_epd": 0.6, @@ -336,7 +336,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "exam/treatment", + "electric_equipment_space_type_name": "exam_treatment_electric_equipment", "electric_equipment_minimum_epd": 0.51, "electric_equipment_average_epd": 0.56, "electric_equipment_median_epd": 0.53, @@ -344,7 +344,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "library - reading", + "electric_equipment_space_type_name": "library_reading_electric_equipment", "electric_equipment_minimum_epd": 0.32, "electric_equipment_average_epd": 0.49, "electric_equipment_median_epd": 0.46, @@ -352,7 +352,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "emergency vehicle garage", + "electric_equipment_space_type_name": "emergency_vehicle_garage_electric_equipment", "electric_equipment_minimum_epd": 0.39, "electric_equipment_average_epd": 0.39, "electric_equipment_median_epd": 0.39, @@ -360,7 +360,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "firestation - sleeping quarters", + "electric_equipment_space_type_name": "firestation_sleeping_quarters_electric_equipment", "electric_equipment_minimum_epd": 0.37, "electric_equipment_average_epd": 0.37, "electric_equipment_median_epd": 0.37, @@ -368,7 +368,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "parking area, interior", + "electric_equipment_space_type_name": "parking_area_interior_electric_equipment", "electric_equipment_minimum_epd": 0.11, "electric_equipment_average_epd": 0.27, "electric_equipment_median_epd": 0.3, @@ -376,7 +376,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "audience seating - gymnasium", + "electric_equipment_space_type_name": "audience_seating_gymnasium_electric_equipment", "electric_equipment_minimum_epd": 0.64, "electric_equipment_average_epd": 0.64, "electric_equipment_median_epd": 0.64, @@ -384,7 +384,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "emergency room", + "electric_equipment_space_type_name": "emergency_room_electric_equipment", "electric_equipment_minimum_epd": 0.61, "electric_equipment_average_epd": 0.62, "electric_equipment_median_epd": 0.62, @@ -392,7 +392,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "patient room", + "electric_equipment_space_type_name": "patient_room_electric_equipment", "electric_equipment_minimum_epd": 0.71, "electric_equipment_average_epd": 0.72, "electric_equipment_median_epd": 0.72, @@ -400,7 +400,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "pharmacy", + "electric_equipment_space_type_name": "pharmacy_electric_equipment", "electric_equipment_minimum_epd": 0.47, "electric_equipment_average_epd": 0.64, "electric_equipment_median_epd": 0.72, @@ -408,7 +408,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "corridor - hospital", + "electric_equipment_space_type_name": "corridor_hospital_electric_equipment", "electric_equipment_minimum_epd": 0.3, "electric_equipment_average_epd": 0.3, "electric_equipment_median_epd": 0.3, @@ -416,7 +416,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "fellowship hall - religious facility", + "electric_equipment_space_type_name": "fellowship_hall_religious_facility_electric_equipment", "electric_equipment_minimum_epd": 0.36, "electric_equipment_average_epd": 0.39, "electric_equipment_median_epd": 0.39, @@ -424,7 +424,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "lounge/breakroom - healthcare facility", + "electric_equipment_space_type_name": "lounge_breakroom_healthcare_facility_electric_equipment", "electric_equipment_minimum_epd": 0.75, "electric_equipment_average_epd": 0.75, "electric_equipment_median_epd": 0.75, @@ -432,7 +432,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "operating room", + "electric_equipment_space_type_name": "operating_room_electric_equipment", "electric_equipment_minimum_epd": 0.77, "electric_equipment_average_epd": 0.77, "electric_equipment_median_epd": 0.77, @@ -440,7 +440,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "physical therapy", + "electric_equipment_space_type_name": "physical_therapy_electric_equipment", "electric_equipment_minimum_epd": 0.73, "electric_equipment_average_epd": 0.73, "electric_equipment_median_epd": 0.73, @@ -448,7 +448,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "storage < 50 sf - hospital", + "electric_equipment_space_type_name": "storage_lt_50_sf_hospital_electric_equipment", "electric_equipment_minimum_epd": 0, "electric_equipment_average_epd": 0, "electric_equipment_median_epd": 0, @@ -456,7 +456,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "storage 50 to 1000 sf - hospital", + "electric_equipment_space_type_name": "storage_50_to_1000_sf_hospital_electric_equipment", "electric_equipment_minimum_epd": 0, "electric_equipment_average_epd": 0, "electric_equipment_median_epd": 0, @@ -464,7 +464,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "guest room", + "electric_equipment_space_type_name": "guest_room_electric_equipment", "electric_equipment_minimum_epd": 0.47, "electric_equipment_average_epd": 0.53, "electric_equipment_median_epd": 0.53, @@ -472,7 +472,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "lobby - hotel", + "electric_equipment_space_type_name": "lobby_hotel_electric_equipment", "electric_equipment_minimum_epd": 0.5, "electric_equipment_average_epd": 0.5, "electric_equipment_median_epd": 0.5, @@ -480,7 +480,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "library - cataloging", + "electric_equipment_space_type_name": "library_cataloging_electric_equipment", "electric_equipment_minimum_epd": 0.21, "electric_equipment_average_epd": 0.21, "electric_equipment_median_epd": 0.21, @@ -488,7 +488,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "museum exhibit area", + "electric_equipment_space_type_name": "museum_exhibit_area_electric_equipment", "electric_equipment_minimum_epd": 0.32, "electric_equipment_average_epd": 0.46, "electric_equipment_median_epd": 0.43, @@ -496,7 +496,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "corridor - manufacturing facility", + "electric_equipment_space_type_name": "corridor_manufacturing_facility_electric_equipment", "electric_equipment_minimum_epd": 0.38, "electric_equipment_average_epd": 0.38, "electric_equipment_median_epd": 0.38, @@ -504,7 +504,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "manufacturing equipment room", + "electric_equipment_space_type_name": "manufacturing_equipment_room_electric_equipment", "electric_equipment_minimum_epd": 0, "electric_equipment_average_epd": 0, "electric_equipment_median_epd": 0, @@ -512,7 +512,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "manufacturing low bay", + "electric_equipment_space_type_name": "manufacturing_low_bay_electric_equipment", "electric_equipment_minimum_epd": 0.67, "electric_equipment_average_epd": 0.67, "electric_equipment_median_epd": 0.67, @@ -520,7 +520,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "performing arts dressing room", + "electric_equipment_space_type_name": "performing_arts_dressing_room_electric_equipment", "electric_equipment_minimum_epd": 0.29, "electric_equipment_average_epd": 0.41, "electric_equipment_median_epd": 0.43, @@ -528,7 +528,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "audience seating - auditorium", + "electric_equipment_space_type_name": "audience_seating_auditorium_electric_equipment", "electric_equipment_minimum_epd": 0.26, "electric_equipment_average_epd": 0.29, "electric_equipment_median_epd": 0.29, @@ -536,7 +536,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "audience seating - motion picture theater", + "electric_equipment_space_type_name": "audience_seating_motion_picture_theater_electric_equipment", "electric_equipment_minimum_epd": 0.28, "electric_equipment_average_epd": 0.28, "electric_equipment_median_epd": 0.28, @@ -544,7 +544,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "lobby - motion picture theater", + "electric_equipment_space_type_name": "lobby_motion_picture_theater_electric_equipment", "electric_equipment_minimum_epd": 0.33, "electric_equipment_average_epd": 0.33, "electric_equipment_median_epd": 0.33, @@ -552,7 +552,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "Dwelling Unit", + "electric_equipment_space_type_name": "dwelling_unit_electric_equipment", "electric_equipment_minimum_epd": 0.25, "electric_equipment_average_epd": 0.25, "electric_equipment_median_epd": 0.25, @@ -560,7 +560,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "museum restoration", + "electric_equipment_space_type_name": "museum_restoration_electric_equipment", "electric_equipment_minimum_epd": 0.21, "electric_equipment_average_epd": 0.21, "electric_equipment_median_epd": 0.21, @@ -568,7 +568,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "banking activity", + "electric_equipment_space_type_name": "banking_activity_electric_equipment", "electric_equipment_minimum_epd": 0.54, "electric_equipment_average_epd": 0.55, "electric_equipment_median_epd": 0.55, @@ -576,7 +576,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "warehouse - fine storage", + "electric_equipment_space_type_name": "warehouse_fine_storage_electric_equipment", "electric_equipment_minimum_epd": 0, "electric_equipment_average_epd": 0.06, "electric_equipment_median_epd": 0.06, @@ -584,7 +584,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "classroom/lecture/training - penitentiary", + "electric_equipment_space_type_name": "classroom_lecture_training_penitentiary_electric_equipment", "electric_equipment_minimum_epd": 0.41, "electric_equipment_average_epd": 0.41, "electric_equipment_median_epd": 0.41, @@ -592,7 +592,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "dining - penitentiary", + "electric_equipment_space_type_name": "dining_penitentiary_electric_equipment", "electric_equipment_minimum_epd": 0.35, "electric_equipment_average_epd": 0.35, "electric_equipment_median_epd": 0.35, @@ -600,7 +600,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "audience seating - performing arts theater", + "electric_equipment_space_type_name": "audience_seating_performing_arts_theater_electric_equipment", "electric_equipment_minimum_epd": 0.27, "electric_equipment_average_epd": 0.27, "electric_equipment_median_epd": 0.27, @@ -608,7 +608,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "lobby - performing arts theater", + "electric_equipment_space_type_name": "lobby_performing_arts_theater_electric_equipment", "electric_equipment_minimum_epd": 0.33, "electric_equipment_average_epd": 0.33, "electric_equipment_median_epd": 0.33, @@ -616,7 +616,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "audience seating - religious facility", + "electric_equipment_space_type_name": "audience_seating_religious_facility_electric_equipment", "electric_equipment_minimum_epd": 0.41, "electric_equipment_average_epd": 0.41, "electric_equipment_median_epd": 0.41, @@ -624,7 +624,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "worship/pulpit/choir area", + "electric_equipment_space_type_name": "worship_pulpit_choir_area_electric_equipment", "electric_equipment_minimum_epd": 0.42, "electric_equipment_average_epd": 0.42, "electric_equipment_median_epd": 0.42, @@ -632,7 +632,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "classroom/lecture/training - preschool to 12th", + "electric_equipment_space_type_name": "classroom_lecture_training_preschool_to_12th_electric_equipment", "electric_equipment_minimum_epd": 0.67, "electric_equipment_average_epd": 0.67, "electric_equipment_median_epd": 0.67, @@ -640,7 +640,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "sports arena playing area, class II", + "electric_equipment_space_type_name": "sports_arena_playing_area_class_ii_electric_equipment", "electric_equipment_minimum_epd": 0.32, "electric_equipment_average_epd": 0.48, "electric_equipment_median_epd": 0.48, @@ -648,7 +648,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "audience seating - sports arena", + "electric_equipment_space_type_name": "audience_seating_sports_arena_electric_equipment", "electric_equipment_minimum_epd": 0.38, "electric_equipment_average_epd": 0.38, "electric_equipment_median_epd": 0.38, @@ -656,7 +656,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "airport concourse", + "electric_equipment_space_type_name": "airport_concourse_electric_equipment", "electric_equipment_minimum_epd": 0.52, "electric_equipment_average_epd": 0.52, "electric_equipment_median_epd": 0.52, @@ -664,7 +664,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "atrium < 20 ft height", + "electric_equipment_space_type_name": "atrium_lt_20_ft_height_electric_equipment", "electric_equipment_minimum_epd": 0.53, "electric_equipment_average_epd": 0.53, "electric_equipment_median_epd": 0.53, @@ -672,7 +672,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "atrium > 40 ft height", + "electric_equipment_space_type_name": "atrium_gt_40_ft_height_electric_equipment", "electric_equipment_minimum_epd": 0.53, "electric_equipment_average_epd": 0.53, "electric_equipment_median_epd": 0.53, @@ -680,7 +680,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "atrium >= 20 ft and <= 40 ft in height", + "electric_equipment_space_type_name": "atrium_gte_20_ft_and_lte_40_ft_in_height_electric_equipment", "electric_equipment_minimum_epd": 0.53, "electric_equipment_average_epd": 0.53, "electric_equipment_median_epd": 0.53, @@ -688,7 +688,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "baggage/carousel", + "electric_equipment_space_type_name": "baggage_carousel_electric_equipment", "electric_equipment_minimum_epd": 0.55, "electric_equipment_average_epd": 0.55, "electric_equipment_median_epd": 0.55, @@ -696,7 +696,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "seating area, general", + "electric_equipment_space_type_name": "seating_area_general_electric_equipment", "electric_equipment_minimum_epd": 0.25, "electric_equipment_average_epd": 0.25, "electric_equipment_median_epd": 0.25, @@ -704,7 +704,7 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "transportation ticket counter", + "electric_equipment_space_type_name": "transportation_ticket_counter_electric_equipment", "electric_equipment_minimum_epd": 0.74, "electric_equipment_average_epd": 0.74, "electric_equipment_median_epd": 0.74, @@ -712,11 +712,35 @@ "electric_equipment_epd_unit": "W/ft2" }, { - "electric_equipment_space_type_name": "warehouse - bulk storage", + "electric_equipment_space_type_name": "warehouse_bulk_storage_electric_equipment", "electric_equipment_minimum_epd": 0.11, "electric_equipment_average_epd": 0.11, "electric_equipment_median_epd": 0.11, "electric_equipment_maximum_epd": 0.11, "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "attic_electric_equipment", + "electric_equipment_minimum_epd": 0, + "electric_equipment_average_epd": 0, + "electric_equipment_median_epd": 0, + "electric_equipment_maximum_epd": 0, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "plenum_electric_equipment", + "electric_equipment_minimum_epd": 0, + "electric_equipment_average_epd": 0, + "electric_equipment_median_epd": 0, + "electric_equipment_maximum_epd": 0, + "electric_equipment_epd_unit": "W/ft2" + }, + { + "electric_equipment_space_type_name": "shaft_electric_equipment", + "electric_equipment_minimum_epd": 0, + "electric_equipment_average_epd": 0, + "electric_equipment_median_epd": 0, + "electric_equipment_maximum_epd": 0, + "electric_equipment_epd_unit": "W/ft2" } ] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/level_2_lighting_space_types.csv b/data/openstudio_standards_data/database_files/level_2_lighting_space_types.csv index 7eaf0760dd..11fac599dc 100644 --- a/data/openstudio_standards_data/database_files/level_2_lighting_space_types.csv +++ b/data/openstudio_standards_data/database_files/level_2_lighting_space_types.csv @@ -1,287 +1,709 @@ -lighting_space_type_name,level_3_lighting_definition_table,level_3_lighting_definition_id -bam_automotive_facility,level_3_lighting_90_1_2004,1 -bam_convention_center,level_3_lighting_90_1_2004,2 -bam_courthouse,level_3_lighting_90_1_2004,3 -bam_dinin_bar_lounge_leisure,level_3_lighting_90_1_2004,4 -bam_dining_cafeteria_fast_food,level_3_lighting_90_1_2004,5 -bam_dining_family,level_3_lighting_90_1_2004,6 -bam_dormitory,level_3_lighting_90_1_2004,7 -bam_exercise_center,level_3_lighting_90_1_2004,8 -bam_fire_station,level_3_lighting_90_1_2004,23 -bam_gymnasium,level_3_lighting_90_1_2004,9 -bam_healthcare_clinic,level_3_lighting_90_1_2004,10 -bam_hospital,level_3_lighting_90_1_2004,11 -bam_hotel,level_3_lighting_90_1_2004,12 -bam_library,level_3_lighting_90_1_2004,13 -bam_manufacturing_facility,level_3_lighting_90_1_2004,14 -bam_motel,level_3_lighting_90_1_2004,15 -bam_motion_picture_theater,level_3_lighting_90_1_2004,16 -bam_multifamily,level_3_lighting_90_1_2004,17 -bam_museum,level_3_lighting_90_1_2004,18 -bam_office,level_3_lighting_90_1_2004,19 -bam_parking_garage,level_3_lighting_90_1_2004,20 -bam_penitentiary,level_3_lighting_90_1_2004,21 -bam_performing_arts_theater,level_3_lighting_90_1_2004,22 -bam_police_station,level_3_lighting_90_1_2004,23 -bam_post_office,level_3_lighting_90_1_2004,24 -bam_religious_facility,level_3_lighting_90_1_2004,25 -bam_retail,level_3_lighting_90_1_2004,26 -bam_school_university,level_3_lighting_90_1_2004,27 -bam_sports_arena,level_3_lighting_90_1_2004,28 -bam_town_hall,level_3_lighting_90_1_2004,29 -bam_transportation,level_3_lighting_90_1_2004,30 -bam_warehouse,level_3_lighting_90_1_2004,31 -bam_workshop,level_3_lighting_90_1_2004,32 -office_enclosed_small,level_3_lighting_90_1_2004,33 -office_enclosed_large,level_3_lighting_90_1_2004,33 -office_open,level_3_lighting_90_1_2004,34 -conference_meeting_multipurpose,level_3_lighting_90_1_2004,35 -classroom_lecture_training_general,level_3_lighting_90_1_2004,36 -classroom_lecture_training_penitentiary,level_3_lighting_90_1_2004,37 -lobby_general,level_3_lighting_90_1_2004,38 -lobby_hotel,level_3_lighting_90_1_2004,39 -lobby_performing_arts_theater,level_3_lighting_90_1_2004,40 -lobby_motion_picture_theater,level_3_lighting_90_1_2004,41 -lobby_visually_impaired,level_3_lighting_90_1_2004,38 -lobby_elevator,level_3_lighting_90_1_2004,38 -audience_seating_general,level_3_lighting_90_1_2004,42 -audience_seating_gymnasium,level_3_lighting_90_1_2004,43 -audience_seating_exercise_center,level_3_lighting_90_1_2004,44 -audience_seating_convention_center,level_3_lighting_90_1_2004,45 -audience_seating_penitentiary,level_3_lighting_90_1_2004,46 -audience_seating_religious_facility,level_3_lighting_90_1_2004,47 -audience_seating_sports_arena,level_3_lighting_90_1_2004,48 -audience_seating_performing_arts_theater,level_3_lighting_90_1_2004,49 -audience_seating_motion_picture_theater,level_3_lighting_90_1_2004,50 -audience_seating_transportation,level_3_lighting_90_1_2004,51 -audience_seating_auditorium,level_3_lighting_90_1_2004,42 -atrium_first_three_floor,level_3_lighting_90_1_2004,52 -atrium_each_additional_floor,level_3_lighting_90_1_2004,53 -lounge_breakroom_general,level_3_lighting_90_1_2004,54 -lounge_breakroom_healthcare_facility,level_3_lighting_90_1_2004,55 -dining_general,level_3_lighting_90_1_2004,56 -dining_penitentiary,level_3_lighting_90_1_2004,57 -dining_hotel,level_3_lighting_90_1_2004,58 -dining_motel,level_3_lighting_90_1_2004,59 -dining_bar_lounge_leisure,level_3_lighting_90_1_2004,60 -dining_family,level_3_lighting_90_1_2004,61 -dining_cafeteria_fast_food,level_3_lighting_90_1_2004,56 -dining_visually_impaired,level_3_lighting_90_1_2004,56 -kitchen,level_3_lighting_90_1_2004,62 -laboratory_classroom,level_3_lighting_90_1_2004,63 -laboratory_all_other,level_3_lighting_90_1_2004,63 -restroom_visually_impaired,level_3_lighting_90_1_2004,64 -restroom_all_other,level_3_lighting_90_1_2004,64 -performing_arts_dressing_room,level_3_lighting_90_1_2004,65 -corridor_general,level_3_lighting_90_1_2004,66 -corridor_hospital,level_3_lighting_90_1_2004,67 -corridor_manufacturing_facility,level_3_lighting_90_1_2004,68 -corridor_visually_impaired,level_3_lighting_90_1_2004,66 -stairway,level_3_lighting_90_1_2004,69 -stairwell,level_3_lighting_90_1_2004,69 -storage_ all_other_small,level_3_lighting_90_1_2004,70 -storage_ all_other_large,level_3_lighting_90_1_2004,70 -storage_hospital_small,level_3_lighting_90_1_2004,71 -storage_hospital_large,level_3_lighting_90_1_2004,71 -storage_inactive,level_3_lighting_90_1_2004,72 -storage_inactive_museum,level_3_lighting_90_1_2004,73 -electrical_mechanical,level_3_lighting_90_1_2004,74 -workshop,level_3_lighting_90_1_2004,75 -gymnasium_playing_area,level_3_lighting_90_1_2004,76 -gymnasium_exercise_area,level_3_lighting_90_1_2004,77 -courtroom,level_3_lighting_90_1_2004,78 -confinement_cells,level_3_lighting_90_1_2004,79 -judges_chambers,level_3_lighting_90_1_2004,80 -emergency_vehicle_garage,level_3_lighting_90_1_2004,81 -firestation_sleeping_quarters,level_3_lighting_90_1_2004,82 -post_office_sorting_area,level_3_lighting_90_1_2004,83 -exhibit_convention_center,level_3_lighting_90_1_2004,84 -library_cataloging,level_3_lighting_90_1_2004,85 -library_stacks,level_3_lighting_90_1_2004,86 -library_reading,level_3_lighting_90_1_2004,87 -emergency_room,level_3_lighting_90_1_2004,88 -recovery,level_3_lighting_90_1_2004,89 -nurses_station,level_3_lighting_90_1_2004,90 -exam_treatment,level_3_lighting_90_1_2004,91 -pharmacy,level_3_lighting_90_1_2004,92 -patient_room,level_3_lighting_90_1_2004,93 -operating_room,level_3_lighting_90_1_2004,94 -nursery,level_3_lighting_90_1_2004,95 -medical_supply,level_3_lighting_90_1_2004,96 -physical_therapy,level_3_lighting_90_1_2004,97 -imaging,level_3_lighting_90_1_2004,98 -laundry_washing,level_3_lighting_90_1_2004,99 -automotive,level_3_lighting_90_1_2004,100 -manufacturing_low_bay,level_3_lighting_90_1_2004,101 -manufacturing_high_bay,level_3_lighting_90_1_2004,102 -detailed_manufacuring,level_3_lighting_90_1_2004,103 -manufacturing_equipment_room,level_3_lighting_90_1_2004,104 -manufacturing_control,level_3_lighting_90_1_2004,105 -guest_room,level_3_lighting_90_1_2004,106 -dormitory_living_quarters,level_3_lighting_90_1_2004,107 -museum_exhibit_area,level_3_lighting_90_1_2004,108 -museum_restoration,level_3_lighting_90_1_2004,109 -banking_activity,level_3_lighting_90_1_2004,110 -worship_pulpit_choir_area,level_3_lighting_90_1_2004,111 -fellowship_hall_religious_facility,level_3_lighting_90_1_2004,112 -sales,level_3_lighting_90_1_2004,113 -retail_mall_concourse,level_3_lighting_90_1_2004,114 -sports_arena_ring_sports_area,level_3_lighting_90_1_2004,115 -sports_arena_court_sports_area,level_3_lighting_90_1_2004,116 -sports_arena_indoor_playing_field,level_3_lighting_90_1_2004,117 -warehouse_bulk_storage,level_3_lighting_90_1_2004,119 -parking_area_interior,level_3_lighting_90_1_2004,120 -airport_concourse,level_3_lighting_90_1_2004,121 -baggage_carousel,level_3_lighting_90_1_2004,122 -transportation_ticket_counter,level_3_lighting_90_1_2004,123 -sales_display_type_1,level_3_lighting_90_1_2004,124 -sales_display_type_2,level_3_lighting_90_1_2004,124 -sales_display_type_3,level_3_lighting_90_1_2004,125 -sales_display_type_4,level_3_lighting_90_1_2004,125 -bam_automotive_facility,level_3_lighting_90_1_2019,1 -bam_convention_center,level_3_lighting_90_1_2019,2 -bam_courthouse,level_3_lighting_90_1_2019,3 -bam_dinin_bar_lounge_leisure,level_3_lighting_90_1_2019,4 -bam_dining_cafeteria_fast_food,level_3_lighting_90_1_2019,5 -bam_dining_family,level_3_lighting_90_1_2019,6 -bam_dormitory,level_3_lighting_90_1_2019,7 -bam_exercise_center,level_3_lighting_90_1_2019,8 -bam_fire_station,level_3_lighting_90_1_2019,9 -bam_gymnasium,level_3_lighting_90_1_2019,10 -bam_healthcare_clinic,level_3_lighting_90_1_2019,11 -bam_hospital,level_3_lighting_90_1_2019,12 -bam_hotel,level_3_lighting_90_1_2019,13 -bam_library,level_3_lighting_90_1_2019,14 -bam_manufacturing_facility,level_3_lighting_90_1_2019,15 -bam_motel,level_3_lighting_90_1_2019,13 -bam_motion_picture_theater,level_3_lighting_90_1_2019,16 -bam_multifamily,level_3_lighting_90_1_2019,17 -bam_museum,level_3_lighting_90_1_2019,18 -bam_office,level_3_lighting_90_1_2019,19 -bam_parking_garage,level_3_lighting_90_1_2019,20 -bam_penitentiary,level_3_lighting_90_1_2019,21 -bam_performing_arts_theater,level_3_lighting_90_1_2019,22 -bam_police_station,level_3_lighting_90_1_2019,23 -bam_post_office,level_3_lighting_90_1_2019,24 -bam_religious_facility,level_3_lighting_90_1_2019,25 -bam_retail,level_3_lighting_90_1_2019,26 -bam_school_university,level_3_lighting_90_1_2019,27 -bam_sports_arena,level_3_lighting_90_1_2019,28 -bam_town_hall,level_3_lighting_90_1_2019,29 -bam_transportation,level_3_lighting_90_1_2019,30 -bam_warehouse,level_3_lighting_90_1_2019,31 -bam_workshop,level_3_lighting_90_1_2019,32 -office_enclosed_small,level_3_lighting_90_1_2019,79 -office_enclosed_large,level_3_lighting_90_1_2019,80 -office_open,level_3_lighting_90_1_2019,81 -conference_meeting_multipurpose,level_3_lighting_90_1_2019,48 -classroom_lecture_training_general,level_3_lighting_90_1_2019,47 -classroom_lecture_training_penitentiary,level_3_lighting_90_1_2019,46 -lobby_general,level_3_lighting_90_1_2019,75 -lobby_hotel,level_3_lighting_90_1_2019,72 -lobby_performing_arts_theater,level_3_lighting_90_1_2019,74 -lobby_motion_picture_theater,level_3_lighting_90_1_2019,73 -lobby_visually_impaired,level_3_lighting_90_1_2019,70 -lobby_elevator,level_3_lighting_90_1_2019,71 -audience_seating_general,level_3_lighting_90_1_2019,43 -audience_seating_gymnasium,level_3_lighting_90_1_2019,37 -audience_seating_exercise_center,level_3_lighting_90_1_2019,43 -audience_seating_convention_center,level_3_lighting_90_1_2019,43 -audience_seating_penitentiary,level_3_lighting_90_1_2019,39 -audience_seating_religious_facility,level_3_lighting_90_1_2019,41 -audience_seating_sports_arena,level_3_lighting_90_1_2019,42 -audience_seating_performing_arts_theater,level_3_lighting_90_1_2019,40 -audience_seating_motion_picture_theater,level_3_lighting_90_1_2019,38 -audience_seating_transportation,level_3_lighting_90_1_2019,43 -audience_seating_auditorium,level_3_lighting_90_1_2019,36 -atrium_low,level_3_lighting_90_1_2019,33 -atrium_medium,level_3_lighting_90_1_2019,34 -atrium_high,level_3_lighting_90_1_2019,35 -lounge_breakroom_general,level_3_lighting_90_1_2019,78 -lounge_breakroom_healthcare_facility,level_3_lighting_90_1_2019,77 -dining_general,level_3_lighting_90_1_2019,61 -dining_penitentiary,level_3_lighting_90_1_2019,56 -dining_hotel,level_3_lighting_90_1_2019,61 -dining_motel,level_3_lighting_90_1_2019,61 -dining_bar_lounge_leisure,level_3_lighting_90_1_2019,58 -dining_family,level_3_lighting_90_1_2019,60 -dining_cafeteria_fast_food,level_3_lighting_90_1_2019,59 -dining_visually_impaired,level_3_lighting_90_1_2019,57 -kitchen,level_3_lighting_90_1_2019,64 -laboratory_classroom,level_3_lighting_90_1_2019,66 -laboratory_all_other,level_3_lighting_90_1_2019,67 -restroom_visually_impaired,level_3_lighting_90_1_2019,84 -restroom_all_other,level_3_lighting_90_1_2019,85 -performing_arts_dressing_room,level_3_lighting_90_1_2019,120 -corridor_general,level_3_lighting_90_1_2019,53 -corridor_hospital,level_3_lighting_90_1_2019,52 -corridor_manufacturing_facility,level_3_lighting_90_1_2019,53 -corridor_visually_impaired,level_3_lighting_90_1_2019,51 -stairway,level_3_lighting_90_1_2019,88 -stairwell,level_3_lighting_90_1_2019,89 -storage_ all_other_small,level_3_lighting_90_1_2019,90 -storage_ all_other_large,level_3_lighting_90_1_2019,91 -storage_hospital_small,level_3_lighting_90_1_2019,90 -storage_hospital_large,level_3_lighting_90_1_2019,91 -electrical_mechanical,level_3_lighting_90_1_2019,62 -workshop,level_3_lighting_90_1_2019,93 -gymnasium_playing_area,level_3_lighting_90_1_2019,101 -gymnasium_exercise_area,level_3_lighting_90_1_2019,100 -courtroom,level_3_lighting_90_1_2019,54 -confinement_cells,level_3_lighting_90_1_2019,49 -emergency_vehicle_garage,level_3_lighting_90_1_2019,63 -firestation_sleeping_quarters,level_3_lighting_90_1_2019,99 -post_office_sorting_area,level_3_lighting_90_1_2019,121 -exhibit_convention_center,level_3_lighting_90_1_2019,97 -library_stacks,level_3_lighting_90_1_2019,112 -library_reading,level_3_lighting_90_1_2019,111 -recovery,level_3_lighting_90_1_2019,110 -nurses_station,level_3_lighting_90_1_2019,106 -exam_treatment,level_3_lighting_90_1_2019,102 -pharmacy,level_3_lighting_90_1_2019,83 -patient_room,level_3_lighting_90_1_2019,108 -operating_room,level_3_lighting_90_1_2019,107 -nursery,level_3_lighting_90_1_2019,105 -medical_supply,level_3_lighting_90_1_2019,104 -physical_therapy,level_3_lighting_90_1_2019,109 -imaging,level_3_lighting_90_1_2019,103 -laundry_washing,level_3_lighting_90_1_2019,68 -automotive,level_3_lighting_90_1_2019,96 -manufacturing_low_bay,level_3_lighting_90_1_2019,117 -manufacturing_high_bay,level_3_lighting_90_1_2019,116 -detailed_manufacuring,level_3_lighting_90_1_2019,113 -manufacturing_equipment_room,level_3_lighting_90_1_2019,114 -manufacturing_extra_high_bay,level_3_lighting_90_1_2019,115 -guest_room,level_3_lighting_90_1_2019,65 -dormitory_living_quarters,level_3_lighting_90_1_2019,98 -museum_exhibit_area,level_3_lighting_90_1_2019,118 -museum_restoration,level_3_lighting_90_1_2019,119 -banking_activity,level_3_lighting_90_1_2019,44 -worship_pulpit_choir_area,level_3_lighting_90_1_2019,123 -fellowship_hall_religious_facility,level_3_lighting_90_1_2019,122 -sales,level_3_lighting_90_1_2019,86 -retail_mall_concourse,level_3_lighting_90_1_2019,125 -retail_dressing_room,level_3_lighting_90_1_2019,124 -sports_arena_playing_area_class_I,level_3_lighting_90_1_2019,126 -sports_arena_playing_area_class_II,level_3_lighting_90_1_2019,127 -sports_arena_playing_area_class_III,level_3_lighting_90_1_2019,128 -sports_arena_playing_area_class_IV,level_3_lighting_90_1_2019,129 -warehouse_fine_storage,level_3_lighting_90_1_2019,134 -warehouse_bulk_storage,level_3_lighting_90_1_2019,133 -parking_area_interior,level_3_lighting_90_1_2019,82 -airport_concourse,level_3_lighting_90_1_2019,131 -baggage_carousel,level_3_lighting_90_1_2019,130 -transportation_ticket_counter,level_3_lighting_90_1_2019,132 -sales_display_type_1,level_3_lighting_90_1_2019,135 -sales_display_type_2,level_3_lighting_90_1_2019,136 -sales_display_type_3,level_3_lighting_90_1_2019,137 -sales_display_type_4,level_3_lighting_90_1_2019,138 -breakroom,level_3_lighting_90_1_2019,45 -copy_print,level_3_lighting_90_1_2019,50 -computer_room,level_3_lighting_90_1_2019,55 -loading_dock,level_3_lighting_90_1_2019,69 -locker_room,level_3_lighting_90_1_2019,76 -seating_area_general,level_3_lighting_90_1_2019,87 -vehicular_maintenance,level_3_lighting_90_1_2019,92 -chapel_visually_impaired,level_3_lighting_90_1_2019,94 -recreation_common_living_visually_impaired,level_3_lighting_90_1_2019,95 +lighting_space_type_name,level_3_lighting_code_definition_table,level_3_lighting_code_definition_id,lighting_technology_name,lighting_space_type_target_illuminance_setpoint +airport_concourse_lighting,level_3_lighting_90_1_2004,122,default,118 +atrium_lighting,level_3_lighting_90_1_2004,36,default,178 +none_lighting,level_3_lighting_90_1_2004,126,default,0 +audience_seating_lighting,level_3_lighting_90_1_2004,46,default,118 +baggage_carousel_lighting,level_3_lighting_90_1_2004,121,default,237 +banking_lighting,level_3_lighting_90_1_2004,77,default,355 +classroom_lecture_training_lighting,level_3_lighting_90_1_2004,48,default,471 +computer_room_lighting,level_3_lighting_90_1_2004,48,default,710 +conference_meeting_multipurpose_lighting,level_3_lighting_90_1_2004,49,default,355 +confinement_cells_lighting,level_3_lighting_90_1_2004,79,default,296 +copy_print_lighting,level_3_lighting_90_1_2004,49,default,178 +corridor_lighting,level_3_lighting_90_1_2004,52,default,178 +courtroom_lighting,level_3_lighting_90_1_2004,80,default,474 +datacenterhighite_lighting,level_3_lighting_90_1_2004,60,default,118 +datacenterlowite_lighting,level_3_lighting_90_1_2004,60,default,118 +dining_lighting,level_3_lighting_90_1_2004,58,default,308 +dressing_room_lighting,level_3_lighting_90_1_2004,59,default,237 +electrical_mechanical_lighting,level_3_lighting_90_1_2004,60,default,118 +emergency_room_lighting,level_3_lighting_90_1_2004,87,default,888 +emergency_vehicle_garage_lighting,level_3_lighting_90_1_2004,83,default,355 +exam_treatment_lighting,level_3_lighting_90_1_2004,88,default,592 +exercise_area_lighting,level_3_lighting_90_1_2004,85,default,474 +exhibit_lighting,level_3_lighting_90_1_2004,108,default,431 +guest_room_lighting,level_3_lighting_90_1_2004,99,default,178 +imaging_lighting,level_3_lighting_90_1_2004,97,default,355 +interior_parking_lighting,level_3_lighting_90_1_2004,110,default,54 +judges_chambers_lighting,level_3_lighting_90_1_2004,81,default,355 +food_preparation_lighting,level_3_lighting_90_1_2004,61,default,538 +laboratory_lighting,level_3_lighting_90_1_2004,64,default,592 +laundry_washing_lighting,level_3_lighting_90_1_2004,89,default,355 +library_lighting,level_3_lighting_90_1_2004,13,default,118 +living_quarters_lighting,level_3_lighting_90_1_2004,82,default,178 +loading_dock_lighting,level_3_lighting_90_1_2004,30,default,355 +lobby_lighting,level_3_lighting_90_1_2004,68,default,296 +locker_room_lighting,level_3_lighting_90_1_2004,59,default,237 +lounge_breakroom_lighting,level_3_lighting_90_1_2004,70,default,178 +manufacturing_lighting,level_3_lighting_90_1_2004,14,default,592 +medical_supply_lighting,level_3_lighting_90_1_2004,90,default,355 +multifamily_lighting,level_3_lighting_90_1_2004,17,default,178 +nursery_lighting,level_3_lighting_90_1_2004,92,default,355 +nurses_station_lighting,level_3_lighting_90_1_2004,91,default,355 +office_lighting,level_3_lighting_90_1_2004,19,default,414 +office_enclosed_lighting,level_3_lighting_90_1_2004,71,default,355 +operating_room_lighting,level_3_lighting_90_1_2004,93,default,1184 +patient_room_lighting,level_3_lighting_90_1_2004,94,default,355 +pharmacy_lighting,level_3_lighting_90_1_2004,95,default,888 +physical_therapy_lighting,level_3_lighting_90_1_2004,96,default,474 +playing_area_lighting,level_3_lighting_90_1_2004,86,default,592 +post_office_lighting,level_3_lighting_90_1_2004,24,default,237 +recovery_lighting,level_3_lighting_90_1_2004,98,default,592 +recreation_common_living_lighting,level_3_lighting_90_1_2004,70,default,323 +restroom_lighting,level_3_lighting_90_1_2004,73,default,178 +retail_sales_lighting,level_3_lighting_90_1_2004,117,default,474 +sleeping_quarters_lighting,level_3_lighting_90_1_2004,84,default,59 +sports_arena_lighting,level_3_lighting_90_1_2004,28,default,1184 +stairwell_lighting,level_3_lighting_90_1_2004,74,default,118 +storage_lighting,level_3_lighting_90_1_2004,34,default,118 +transportation_lighting,level_3_lighting_90_1_2004,30,default,237 +vehicular_maintenance_lighting,level_3_lighting_90_1_2004,76,default,355 +workshop_lighting,level_3_lighting_90_1_2004,32,default,592 +worship_lighting,level_3_lighting_90_1_2004,25,default,355 +ba_automotive_facility_lighting,level_3_lighting_90_1_2004,1,default,355 +ba_convention_center_lighting,level_3_lighting_90_1_2004,2,default,118 +ba_courthouse_lighting,level_3_lighting_90_1_2004,3,default,474 +ba_dining_bar_lounge_leisure_lighting,level_3_lighting_90_1_2004,4,default,118 +ba_dining_cafeteria_fast_food_lighting,level_3_lighting_90_1_2004,5,default,237 +ba_dining_family_lighting,level_3_lighting_90_1_2004,6,default,237 +ba_dormitory_lighting,level_3_lighting_90_1_2004,7,default,178 +ba_exercise_center_lighting,level_3_lighting_90_1_2004,8,default,237 +ba_fire_station_lighting,level_3_lighting_90_1_2004,23,default,118 +ba_gymnasium_lighting,level_3_lighting_90_1_2004,9,default,237 +ba_health-care_clinic_lighting,level_3_lighting_90_1_2004,10,default,592 +ba_hospital_lighting,level_3_lighting_90_1_2004,11,default,592 +ba_hotel_motel_lighting,level_3_lighting_90_1_2004,12,default,178 +ba_motion_picture_theater_lighting,level_3_lighting_90_1_2004,16,default,118 +ba_museum_lighting,level_3_lighting_90_1_2004,18,default,118 +ba_parking_garage_lighting,level_3_lighting_90_1_2004,20,default,54 +ba_penitentiary_lighting,level_3_lighting_90_1_2004,21,default,296 +ba_performing_arts_theater_lighting,level_3_lighting_90_1_2004,22,default,426 +ba_police_station_lighting,level_3_lighting_90_1_2004,23,default,118 +ba_school_university_lighting,level_3_lighting_90_1_2004,27,default,471 +ba_town_hall_lighting,level_3_lighting_90_1_2004,29,default,355 +ba_retail_lighting,level_3_lighting_90_1_2004,26,default,474 +ba_warehouse_lighting,level_3_lighting_90_1_2004,31,default,118 +audience_seating_area_for_gymnasium_lighting,level_3_lighting_90_1_2004,39,default,118 +audience_seating_area_for_motion_picture_theater_lighting,level_3_lighting_90_1_2004,40,default,118 +audience_seating_area_for_penitentiary_lighting,level_3_lighting_90_1_2004,41,default,355 +audience_seating_area_for_performing_arts_theater_lighting,level_3_lighting_90_1_2004,42,default,426 +audience_seating_area_for_religious_buildings_lighting,level_3_lighting_90_1_2004,43,default,118 +audience_seating_area_for_sports_arena_lighting,level_3_lighting_90_1_2004,44,default,118 +classroom_lecture_training_for_penitentiary_lighting,level_3_lighting_90_1_2004,47,default,471 +corridor_transition_for_hospital_lighting,level_3_lighting_90_1_2004,50,default,355 +dining_area_for_penitentiary_lighting,level_3_lighting_90_1_2004,57,default,178 +dining_bar_lounge_leisure_general_lighting,level_3_lighting_90_1_2004,4,default,118 +dining_cafeteria_fast_food_general_lighting,level_3_lighting_90_1_2004,5,default,237 +dining_area_for_family_dining_lighting,level_3_lighting_90_1_2004,54,default,237 +lobby_for_hotel_lighting,level_3_lighting_90_1_2004,65,default,178 +lobby_for_motion_picture_theater_lighting,level_3_lighting_90_1_2004,66,default,118 +lobby_for_performing_arts_theater_lighting,level_3_lighting_90_1_2004,67,default,296 +lounge_recreation_for_hospital_lighting,level_3_lighting_90_1_2004,69,default,296 +office-enclosed_general_lighting,level_3_lighting_90_1_2004,71,default,355 +office_open_plan_lighting,level_3_lighting_90_1_2004,72,default,414 +automotive_general_lighting,level_3_lighting_90_1_2004,76,default,355 +convention_center_exhibit_space_general_lighting,level_3_lighting_90_1_2004,78,default,431 +library_reading_area_lighting,level_3_lighting_90_1_2004,101,default,592 +library_stacks_lighting,level_3_lighting_90_1_2004,102,default,355 +manufacturing_facility_detailed_manufacturing_area_lighting,level_3_lighting_90_1_2004,104,default,592 +manufacturing_facility_equipment_room_lighting,level_3_lighting_90_1_2004,105,default,237 +manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting,level_3_lighting_90_1_2004,106,default,592 +manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting,level_3_lighting_90_1_2004,107,default,592 +museum_restoration_room_lighting,level_3_lighting_90_1_2004,109,default,592 +post_office_sorting_area_general_lighting,level_3_lighting_90_1_2004,111,default,474 +religious_buildings_fellowship_hall_lighting,level_3_lighting_90_1_2004,112,default,355 +religious_buildings_worship_pulpit_choir_lighting,level_3_lighting_90_1_2004,113,default,355 +retail_mall_concourse_lighting,level_3_lighting_90_1_2004,114,default,403 +transportation_facility_ticket_counter_lighting,level_3_lighting_90_1_2004,123,default,296 +warehouse_storage_area_medium_to_bulky_palletized_items_lighting,level_3_lighting_90_1_2004,125,default,355 +warehouse_storage_area_smaller_hand-carried_items_lighting,level_3_lighting_90_1_2004,124,default,237 +airport_concourse_lighting,level_3_lighting_90_1_2007,125,default,118 +atrium_lighting,level_3_lighting_90_1_2007,36,default,178 +none_lighting,level_3_lighting_90_1_2007,129,default,0 +audience_seating_lighting,level_3_lighting_90_1_2007,46,default,118 +baggage_carousel_lighting,level_3_lighting_90_1_2007,124,default,237 +banking_lighting,level_3_lighting_90_1_2007,78,default,355 +classroom_lecture_training_lighting,level_3_lighting_90_1_2007,48,default,471 +computer_room_lighting,level_3_lighting_90_1_2007,48,default,710 +conference_meeting_multipurpose_lighting,level_3_lighting_90_1_2007,49,default,355 +confinement_cells_lighting,level_3_lighting_90_1_2007,80,default,296 +copy_print_lighting,level_3_lighting_90_1_2007,49,default,178 +corridor_lighting,level_3_lighting_90_1_2007,52,default,178 +courtroom_lighting,level_3_lighting_90_1_2007,81,default,474 +datacenterhighite_lighting,level_3_lighting_90_1_2007,60,default,118 +datacenterlowite_lighting,level_3_lighting_90_1_2007,60,default,118 +dining_lighting,level_3_lighting_90_1_2007,58,default,308 +dressing_room_lighting,level_3_lighting_90_1_2007,59,default,237 +electrical_mechanical_lighting,level_3_lighting_90_1_2007,60,default,118 +emergency_room_lighting,level_3_lighting_90_1_2007,88,default,888 +emergency_vehicle_garage_lighting,level_3_lighting_90_1_2007,84,default,355 +exam_treatment_lighting,level_3_lighting_90_1_2007,89,default,592 +exercise_area_lighting,level_3_lighting_90_1_2007,86,default,474 +exhibit_lighting,level_3_lighting_90_1_2007,109,default,431 +guest_room_lighting,level_3_lighting_90_1_2007,100,default,178 +imaging_lighting,level_3_lighting_90_1_2007,98,default,355 +interior_parking_lighting,level_3_lighting_90_1_2007,111,default,54 +judges_chambers_lighting,level_3_lighting_90_1_2007,82,default,355 +food_preparation_lighting,level_3_lighting_90_1_2007,61,default,538 +laboratory_lighting,level_3_lighting_90_1_2007,64,default,592 +laundry_washing_lighting,level_3_lighting_90_1_2007,90,default,355 +library_lighting,level_3_lighting_90_1_2007,13,default,118 +living_quarters_lighting,level_3_lighting_90_1_2007,83,default,178 +loading_dock_lighting,level_3_lighting_90_1_2007,30,default,355 +lobby_lighting,level_3_lighting_90_1_2007,68,default,296 +locker_room_lighting,level_3_lighting_90_1_2007,59,default,237 +lounge_breakroom_lighting,level_3_lighting_90_1_2007,70,default,178 +manufacturing_lighting,level_3_lighting_90_1_2007,14,default,592 +medical_supply_lighting,level_3_lighting_90_1_2007,91,default,355 +multifamily_lighting,level_3_lighting_90_1_2007,17,default,178 +nursery_lighting,level_3_lighting_90_1_2007,93,default,355 +nurses_station_lighting,level_3_lighting_90_1_2007,92,default,355 +office_lighting,level_3_lighting_90_1_2007,19,default,414 +office_enclosed_lighting,level_3_lighting_90_1_2007,71,default,355 +operating_room_lighting,level_3_lighting_90_1_2007,94,default,1184 +patient_room_lighting,level_3_lighting_90_1_2007,95,default,355 +pharmacy_lighting,level_3_lighting_90_1_2007,96,default,888 +physical_therapy_lighting,level_3_lighting_90_1_2007,97,default,474 +playing_area_lighting,level_3_lighting_90_1_2007,87,default,592 +post_office_lighting,level_3_lighting_90_1_2007,24,default,237 +recovery_lighting,level_3_lighting_90_1_2007,99,default,592 +recreation_common_living_lighting,level_3_lighting_90_1_2007,70,default,323 +restroom_lighting,level_3_lighting_90_1_2007,73,default,178 +retail_sales_lighting,level_3_lighting_90_1_2007,120,default,474 +sleeping_quarters_lighting,level_3_lighting_90_1_2007,85,default,59 +sports_arena_lighting,level_3_lighting_90_1_2007,28,default,1184 +stairwell_lighting,level_3_lighting_90_1_2007,75,default,118 +storage_lighting,level_3_lighting_90_1_2007,34,default,118 +transportation_lighting,level_3_lighting_90_1_2007,30,default,237 +vehicular_maintenance_lighting,level_3_lighting_90_1_2007,77,default,355 +workshop_lighting,level_3_lighting_90_1_2007,32,default,592 +worship_lighting,level_3_lighting_90_1_2007,25,default,355 +ba_automotive_facility_lighting,level_3_lighting_90_1_2007,1,default,355 +ba_convention_center_lighting,level_3_lighting_90_1_2007,2,default,118 +ba_courthouse_lighting,level_3_lighting_90_1_2007,3,default,474 +ba_dining_bar_lounge_leisure_lighting,level_3_lighting_90_1_2007,4,default,118 +ba_dining_cafeteria_fast_food_lighting,level_3_lighting_90_1_2007,5,default,237 +ba_dining_family_lighting,level_3_lighting_90_1_2007,6,default,237 +ba_dormitory_lighting,level_3_lighting_90_1_2007,7,default,178 +ba_exercise_center_lighting,level_3_lighting_90_1_2007,8,default,237 +ba_fire_station_lighting,level_3_lighting_90_1_2007,23,default,118 +ba_gymnasium_lighting,level_3_lighting_90_1_2007,9,default,237 +ba_health-care_clinic_lighting,level_3_lighting_90_1_2007,10,default,592 +ba_hospital_lighting,level_3_lighting_90_1_2007,11,default,592 +ba_hotel_motel_lighting,level_3_lighting_90_1_2007,12,default,178 +ba_motion_picture_theater_lighting,level_3_lighting_90_1_2007,16,default,118 +ba_museum_lighting,level_3_lighting_90_1_2007,18,default,118 +ba_parking_garage_lighting,level_3_lighting_90_1_2007,20,default,54 +ba_penitentiary_lighting,level_3_lighting_90_1_2007,21,default,296 +ba_performing_arts_theater_lighting,level_3_lighting_90_1_2007,22,default,426 +ba_police_station_lighting,level_3_lighting_90_1_2007,23,default,118 +ba_school_university_lighting,level_3_lighting_90_1_2007,27,default,471 +ba_town_hall_lighting,level_3_lighting_90_1_2007,29,default,355 +ba_retail_lighting,level_3_lighting_90_1_2007,26,default,474 +ba_warehouse_lighting,level_3_lighting_90_1_2007,31,default,118 +audience_seating_area_for_gymnasium_lighting,level_3_lighting_90_1_2007,39,default,118 +audience_seating_area_for_motion_picture_theater_lighting,level_3_lighting_90_1_2007,40,default,118 +audience_seating_area_for_penitentiary_lighting,level_3_lighting_90_1_2007,41,default,355 +audience_seating_area_for_performing_arts_theater_lighting,level_3_lighting_90_1_2007,42,default,426 +audience_seating_area_for_religious_buildings_lighting,level_3_lighting_90_1_2007,43,default,118 +audience_seating_area_for_sports_arena_lighting,level_3_lighting_90_1_2007,44,default,118 +classroom_lecture_training_for_penitentiary_lighting,level_3_lighting_90_1_2007,47,default,471 +corridor_transition_for_hospital_lighting,level_3_lighting_90_1_2007,50,default,355 +dining_area_for_penitentiary_lighting,level_3_lighting_90_1_2007,57,default,178 +dining_bar_lounge_leisure_general_lighting,level_3_lighting_90_1_2007,4,default,118 +dining_cafeteria_fast_food_general_lighting,level_3_lighting_90_1_2007,5,default,237 +dining_area_for_family_dining_lighting,level_3_lighting_90_1_2007,54,default,237 +lobby_for_hotel_lighting,level_3_lighting_90_1_2007,65,default,178 +lobby_for_motion_picture_theater_lighting,level_3_lighting_90_1_2007,66,default,118 +lobby_for_performing_arts_theater_lighting,level_3_lighting_90_1_2007,67,default,296 +lounge_recreation_for_hospital_lighting,level_3_lighting_90_1_2007,69,default,296 +office-enclosed_general_lighting,level_3_lighting_90_1_2007,71,default,355 +office_open_plan_lighting,level_3_lighting_90_1_2007,72,default,414 +automotive_general_lighting,level_3_lighting_90_1_2007,77,default,355 +convention_center_exhibit_space_general_lighting,level_3_lighting_90_1_2007,79,default,431 +library_reading_area_lighting,level_3_lighting_90_1_2007,102,default,592 +library_stacks_lighting,level_3_lighting_90_1_2007,103,default,355 +manufacturing_facility_detailed_manufacturing_area_lighting,level_3_lighting_90_1_2007,105,default,592 +manufacturing_facility_equipment_room_lighting,level_3_lighting_90_1_2007,106,default,237 +manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting,level_3_lighting_90_1_2007,107,default,592 +manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting,level_3_lighting_90_1_2007,108,default,592 +museum_restoration_room_lighting,level_3_lighting_90_1_2007,110,default,592 +post_office_sorting_area_general_lighting,level_3_lighting_90_1_2007,112,default,474 +religious_buildings_fellowship_hall_lighting,level_3_lighting_90_1_2007,113,default,355 +religious_buildings_worship_pulpit_choir_lighting,level_3_lighting_90_1_2007,114,default,355 +retail_mall_concourse_lighting,level_3_lighting_90_1_2007,115,default,403 +transportation_facility_ticket_counter_lighting,level_3_lighting_90_1_2007,126,default,296 +warehouse_storage_area_medium_to_bulky_palletized_items_lighting,level_3_lighting_90_1_2007,128,default,355 +warehouse_storage_area_smaller_hand-carried_items_lighting,level_3_lighting_90_1_2007,127,default,237 +airport_concourse_lighting,level_3_lighting_90_1_2010,128,default,118 +atrium_lighting,level_3_lighting_90_1_2010,34,default,178 +none_lighting,level_3_lighting_90_1_2010,133,default,0 +audience_seating_lighting,level_3_lighting_90_1_2010,36,default,118 +baggage_carousel_lighting,level_3_lighting_90_1_2010,127,default,237 +banking_lighting,level_3_lighting_90_1_2010,64,default,355 +classroom_lecture_training_lighting,level_3_lighting_90_1_2010,39,default,471 +computer_room_lighting,level_3_lighting_90_1_2010,39,default,710 +conference_meeting_multipurpose_lighting,level_3_lighting_90_1_2010,40,default,355 +confinement_cells_lighting,level_3_lighting_90_1_2010,67,default,296 +copy_print_lighting,level_3_lighting_90_1_2010,40,default,178 +corridor_lighting,level_3_lighting_90_1_2010,41,default,178 +courtroom_lighting,level_3_lighting_90_1_2010,68,default,474 +datacenterhighite_lighting,level_3_lighting_90_1_2010,46,default,118 +datacenterlowite_lighting,level_3_lighting_90_1_2010,46,default,118 +dining_lighting,level_3_lighting_90_1_2010,44,default,308 +dressing_room_lighting,level_3_lighting_90_1_2010,113,default,237 +electrical_mechanical_lighting,level_3_lighting_90_1_2010,46,default,118 +emergency_room_lighting,level_3_lighting_90_1_2010,80,default,888 +emergency_vehicle_garage_lighting,level_3_lighting_90_1_2010,74,default,355 +exam_treatment_lighting,level_3_lighting_90_1_2010,81,default,592 +exercise_area_lighting,level_3_lighting_90_1_2010,76,default,474 +exhibit_lighting,level_3_lighting_90_1_2010,107,default,431 +guest_room_lighting,level_3_lighting_90_1_2010,96,default,178 +imaging_lighting,level_3_lighting_90_1_2010,91,default,355 +interior_parking_lighting,level_3_lighting_90_1_2010,109,default,54 +judges_chambers_lighting,level_3_lighting_90_1_2010,69,default,355 +food_preparation_lighting,level_3_lighting_90_1_2010,47,default,538 +laboratory_lighting,level_3_lighting_90_1_2010,49,default,592 +laundry_washing_lighting,level_3_lighting_90_1_2010,82,default,355 +library_lighting,level_3_lighting_90_1_2010,14,default,118 +living_quarters_lighting,level_3_lighting_90_1_2010,73,default,178 +loading_dock_lighting,level_3_lighting_90_1_2010,31,default,355 +lobby_lighting,level_3_lighting_90_1_2010,53,default,296 +locker_room_lighting,level_3_lighting_90_1_2010,54,default,237 +lounge_breakroom_lighting,level_3_lighting_90_1_2010,55,default,178 +manufacturing_lighting,level_3_lighting_90_1_2010,15,default,592 +medical_supply_lighting,level_3_lighting_90_1_2010,84,default,355 +multifamily_lighting,level_3_lighting_90_1_2010,18,default,178 +nursery_lighting,level_3_lighting_90_1_2010,85,default,355 +nurses_station_lighting,level_3_lighting_90_1_2010,86,default,355 +office_lighting,level_3_lighting_90_1_2010,20,default,414 +office_enclosed_lighting,level_3_lighting_90_1_2010,56,default,355 +operating_room_lighting,level_3_lighting_90_1_2010,87,default,1184 +patient_room_lighting,level_3_lighting_90_1_2010,88,default,355 +pharmacy_lighting,level_3_lighting_90_1_2010,89,default,888 +physical_therapy_lighting,level_3_lighting_90_1_2010,90,default,474 +playing_area_lighting,level_3_lighting_90_1_2010,78,default,592 +post_office_lighting,level_3_lighting_90_1_2010,25,default,237 +recovery_lighting,level_3_lighting_90_1_2010,92,default,592 +recreation_common_living_lighting,level_3_lighting_90_1_2010,55,default,323 +restroom_lighting,level_3_lighting_90_1_2010,58,default,178 +retail_sales_lighting,level_3_lighting_90_1_2010,119,default,474 +sleeping_quarters_lighting,level_3_lighting_90_1_2010,75,default,59 +sports_arena_lighting,level_3_lighting_90_1_2010,29,default,1184 +stairwell_lighting,level_3_lighting_90_1_2010,60,default,118 +storage_lighting,level_3_lighting_90_1_2010,61,default,118 +transportation_lighting,level_3_lighting_90_1_2010,31,default,237 +vehicular_maintenance_lighting,level_3_lighting_90_1_2010,63,default,355 +workshop_lighting,level_3_lighting_90_1_2010,33,default,592 +worship_lighting,level_3_lighting_90_1_2010,26,default,355 +ba_automotive_facility_lighting,level_3_lighting_90_1_2010,1,default,355 +ba_convention_center_lighting,level_3_lighting_90_1_2010,2,default,118 +ba_courthouse_lighting,level_3_lighting_90_1_2010,3,default,474 +ba_dining_bar_lounge_leisure_lighting,level_3_lighting_90_1_2010,4,default,118 +ba_dining_cafeteria_fast_food_lighting,level_3_lighting_90_1_2010,5,default,237 +ba_dining_family_lighting,level_3_lighting_90_1_2010,6,default,237 +ba_dormitory_lighting,level_3_lighting_90_1_2010,7,default,178 +ba_exercise_center_lighting,level_3_lighting_90_1_2010,8,default,237 +ba_fire_station_lighting,level_3_lighting_90_1_2010,9,default,118 +ba_gymnasium_lighting,level_3_lighting_90_1_2010,10,default,237 +ba_health-care_clinic_lighting,level_3_lighting_90_1_2010,11,default,592 +ba_hospital_lighting,level_3_lighting_90_1_2010,12,default,592 +ba_hotel_motel_lighting,level_3_lighting_90_1_2010,13,default,178 +ba_motion_picture_theater_lighting,level_3_lighting_90_1_2010,17,default,118 +ba_museum_lighting,level_3_lighting_90_1_2010,19,default,118 +ba_parking_garage_lighting,level_3_lighting_90_1_2010,21,default,54 +ba_penitentiary_lighting,level_3_lighting_90_1_2010,22,default,296 +ba_performing_arts_theater_lighting,level_3_lighting_90_1_2010,23,default,426 +ba_police_station_lighting,level_3_lighting_90_1_2010,24,default,118 +ba_school_university_lighting,level_3_lighting_90_1_2010,28,default,471 +ba_town_hall_lighting,level_3_lighting_90_1_2010,30,default,355 +ba_retail_lighting,level_3_lighting_90_1_2010,27,default,474 +ba_warehouse_lighting,level_3_lighting_90_1_2010,32,default,118 +audience_seating_area_for_gymnasium_lighting,level_3_lighting_90_1_2010,77,default,118 +audience_seating_area_for_motion_picture_theater_lighting,level_3_lighting_90_1_2010,37,default,118 +audience_seating_area_for_penitentiary_lighting,level_3_lighting_90_1_2010,70,default,355 +audience_seating_area_for_performing_arts_theater_lighting,level_3_lighting_90_1_2010,38,default,426 +audience_seating_area_for_religious_buildings_lighting,level_3_lighting_90_1_2010,110,default,118 +audience_seating_area_for_sports_arena_lighting,level_3_lighting_90_1_2010,120,default,118 +classroom_lecture_training_for_penitentiary_lighting,level_3_lighting_90_1_2010,71,default,471 +corridor_transition_for_hospital_lighting,level_3_lighting_90_1_2010,79,default,355 +dining_area_for_penitentiary_lighting,level_3_lighting_90_1_2010,72,default,178 +dining_bar_lounge_leisure_general_lighting,level_3_lighting_90_1_2010,4,default,118 +dining_cafeteria_fast_food_general_lighting,level_3_lighting_90_1_2010,5,default,237 +dining_area_for_family_dining_lighting,level_3_lighting_90_1_2010,43,default,237 +lobby_for_hotel_lighting,level_3_lighting_90_1_2010,97,default,178 +lobby_for_motion_picture_theater_lighting,level_3_lighting_90_1_2010,51,default,118 +lobby_for_performing_arts_theater_lighting,level_3_lighting_90_1_2010,52,default,296 +lounge_recreation_for_hospital_lighting,level_3_lighting_90_1_2010,83,default,296 +office-enclosed_general_lighting,level_3_lighting_90_1_2010,56,default,355 +office_open_plan_lighting,level_3_lighting_90_1_2010,57,default,414 +automotive_general_lighting,level_3_lighting_90_1_2010,63,default,355 +convention_center_exhibit_space_general_lighting,level_3_lighting_90_1_2010,66,default,431 +library_reading_area_lighting,level_3_lighting_90_1_2010,99,default,592 +library_stacks_lighting,level_3_lighting_90_1_2010,100,default,355 +manufacturing_facility_detailed_manufacturing_area_lighting,level_3_lighting_90_1_2010,102,default,592 +manufacturing_facility_equipment_room_lighting,level_3_lighting_90_1_2010,103,default,237 +manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting,level_3_lighting_90_1_2010,105,default,592 +manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting,level_3_lighting_90_1_2010,106,default,592 +museum_restoration_room_lighting,level_3_lighting_90_1_2010,108,default,592 +post_office_sorting_area_general_lighting,level_3_lighting_90_1_2010,126,default,474 +religious_buildings_fellowship_hall_lighting,level_3_lighting_90_1_2010,111,default,355 +religious_buildings_worship_pulpit_choir_lighting,level_3_lighting_90_1_2010,112,default,355 +retail_mall_concourse_lighting,level_3_lighting_90_1_2010,114,default,403 +transportation_facility_ticket_counter_lighting,level_3_lighting_90_1_2010,130,default,296 +warehouse_storage_area_medium_to_bulky_palletized_items_lighting,level_3_lighting_90_1_2010,132,default,355 +warehouse_storage_area_smaller_hand-carried_items_lighting,level_3_lighting_90_1_2010,131,default,237 +airport_concourse_lighting,level_3_lighting_90_1_2013,140,default,118 +atrium_lighting,level_3_lighting_90_1_2013,33,default,178 +none_lighting,level_3_lighting_90_1_2013,143,default,0 +audience_seating_lighting,level_3_lighting_90_1_2013,36,default,118 +baggage_carousel_lighting,level_3_lighting_90_1_2013,139,default,237 +banking_lighting,level_3_lighting_90_1_2013,45,default,355 +classroom_lecture_training_lighting,level_3_lighting_90_1_2013,47,default,471 +computer_room_lighting,level_3_lighting_90_1_2013,49,default,710 +conference_meeting_multipurpose_lighting,level_3_lighting_90_1_2013,50,default,355 +confinement_cells_lighting,level_3_lighting_90_1_2013,51,default,296 +copy_print_lighting,level_3_lighting_90_1_2013,52,default,178 +corridor_lighting,level_3_lighting_90_1_2013,53,default,178 +courtroom_lighting,level_3_lighting_90_1_2013,57,default,474 +datacenterhighite_lighting,level_3_lighting_90_1_2013,64,default,118 +datacenterlowite_lighting,level_3_lighting_90_1_2013,64,default,118 +dining_lighting,level_3_lighting_90_1_2013,58,default,308 +dressing_room_lighting,level_3_lighting_90_1_2013,128,default,237 +electrical_mechanical_lighting,level_3_lighting_90_1_2013,64,default,118 +emergency_room_lighting,level_3_lighting_90_1_2013,112,default,888 +emergency_vehicle_garage_lighting,level_3_lighting_90_1_2013,65,default,355 +exam_treatment_lighting,level_3_lighting_90_1_2013,112,default,592 +exercise_area_lighting,level_3_lighting_90_1_2013,105,default,474 +exhibit_lighting,level_3_lighting_90_1_2013,122,default,431 +guest_room_lighting,level_3_lighting_90_1_2013,67,default,178 +imaging_lighting,level_3_lighting_90_1_2013,113,default,355 +interior_parking_lighting,level_3_lighting_90_1_2013,84,default,54 +judges_chambers_lighting,level_3_lighting_90_1_2013,57,default,355 +food_preparation_lighting,level_3_lighting_90_1_2013,66,default,538 +laboratory_lighting,level_3_lighting_90_1_2013,68,default,592 +laundry_washing_lighting,level_3_lighting_90_1_2013,70,default,355 +library_lighting,level_3_lighting_90_1_2013,14,default,118 +living_quarters_lighting,level_3_lighting_90_1_2013,99,default,178 +loading_dock_lighting,level_3_lighting_90_1_2013,71,default,355 +lobby_lighting,level_3_lighting_90_1_2013,72,default,296 +locker_room_lighting,level_3_lighting_90_1_2013,78,default,237 +lounge_breakroom_lighting,level_3_lighting_90_1_2013,46,default,178 +manufacturing_lighting,level_3_lighting_90_1_2013,15,default,592 +medical_supply_lighting,level_3_lighting_90_1_2013,106,default,355 +multifamily_lighting,level_3_lighting_90_1_2013,17,default,178 +nursery_lighting,level_3_lighting_90_1_2013,108,default,355 +nurses_station_lighting,level_3_lighting_90_1_2013,107,default,355 +office_lighting,level_3_lighting_90_1_2013,19,default,414 +office_enclosed_lighting,level_3_lighting_90_1_2013,81,default,355 +operating_room_lighting,level_3_lighting_90_1_2013,114,default,1184 +patient_room_lighting,level_3_lighting_90_1_2013,109,default,355 +pharmacy_lighting,level_3_lighting_90_1_2013,106,default,888 +physical_therapy_lighting,level_3_lighting_90_1_2013,110,default,474 +playing_area_lighting,level_3_lighting_90_1_2013,104,default,592 +post_office_lighting,level_3_lighting_90_1_2013,24,default,237 +recovery_lighting,level_3_lighting_90_1_2013,111,default,592 +recreation_common_living_lighting,level_3_lighting_90_1_2013,79,default,323 +restroom_lighting,level_3_lighting_90_1_2013,86,default,178 +retail_sales_lighting,level_3_lighting_90_1_2013,88,default,474 +sleeping_quarters_lighting,level_3_lighting_90_1_2013,103,default,59 +sports_arena_lighting,level_3_lighting_90_1_2013,28,default,1184 +stairwell_lighting,level_3_lighting_90_1_2013,91,default,118 +storage_lighting,level_3_lighting_90_1_2013,94,default,118 +transportation_lighting,level_3_lighting_90_1_2013,30,default,237 +vehicular_maintenance_lighting,level_3_lighting_90_1_2013,95,default,355 +workshop_lighting,level_3_lighting_90_1_2013,32,default,592 +worship_lighting,level_3_lighting_90_1_2013,25,default,355 +ba_automotive_facility_lighting,level_3_lighting_90_1_2013,1,default,355 +ba_convention_center_lighting,level_3_lighting_90_1_2013,2,default,118 +ba_courthouse_lighting,level_3_lighting_90_1_2013,3,default,474 +ba_dining_bar_lounge_leisure_lighting,level_3_lighting_90_1_2013,4,default,118 +ba_dining_cafeteria_fast_food_lighting,level_3_lighting_90_1_2013,5,default,237 +ba_dining_family_lighting,level_3_lighting_90_1_2013,6,default,237 +ba_dormitory_lighting,level_3_lighting_90_1_2013,7,default,178 +ba_exercise_center_lighting,level_3_lighting_90_1_2013,8,default,237 +ba_fire_station_lighting,level_3_lighting_90_1_2013,9,default,118 +ba_gymnasium_lighting,level_3_lighting_90_1_2013,10,default,237 +ba_health-care_clinic_lighting,level_3_lighting_90_1_2013,11,default,592 +ba_hospital_lighting,level_3_lighting_90_1_2013,12,default,592 +ba_hotel_motel_lighting,level_3_lighting_90_1_2013,13,default,178 +ba_motion_picture_theater_lighting,level_3_lighting_90_1_2013,16,default,118 +ba_museum_lighting,level_3_lighting_90_1_2013,18,default,118 +ba_parking_garage_lighting,level_3_lighting_90_1_2013,20,default,54 +ba_penitentiary_lighting,level_3_lighting_90_1_2013,21,default,296 +ba_performing_arts_theater_lighting,level_3_lighting_90_1_2013,22,default,426 +ba_police_station_lighting,level_3_lighting_90_1_2013,23,default,118 +ba_school_university_lighting,level_3_lighting_90_1_2013,27,default,471 +ba_town_hall_lighting,level_3_lighting_90_1_2013,29,default,355 +ba_retail_lighting,level_3_lighting_90_1_2013,26,default,474 +ba_warehouse_lighting,level_3_lighting_90_1_2013,31,default,118 +audience_seating_area_for_gymnasium_lighting,level_3_lighting_90_1_2013,38,default,118 +audience_seating_area_for_motion_picture_theater_lighting,level_3_lighting_90_1_2013,39,default,118 +audience_seating_area_for_penitentiary_lighting,level_3_lighting_90_1_2013,40,default,355 +audience_seating_area_for_performing_arts_theater_lighting,level_3_lighting_90_1_2013,41,default,426 +audience_seating_area_for_religious_buildings_lighting,level_3_lighting_90_1_2013,42,default,118 +audience_seating_area_for_sports_arena_lighting,level_3_lighting_90_1_2013,43,default,118 +classroom_lecture_training_for_penitentiary_lighting,level_3_lighting_90_1_2013,48,default,471 +corridor_transition_for_hospital_lighting,level_3_lighting_90_1_2013,55,default,355 +dining_area_for_penitentiary_lighting,level_3_lighting_90_1_2013,60,default,178 +dining_bar_lounge_leisure_general_lighting,level_3_lighting_90_1_2013,4,default,118 +dining_cafeteria_fast_food_general_lighting,level_3_lighting_90_1_2013,5,default,237 +dining_area_for_family_dining_lighting,level_3_lighting_90_1_2013,63,default,237 +lobby_for_hotel_lighting,level_3_lighting_90_1_2013,75,default,178 +lobby_for_motion_picture_theater_lighting,level_3_lighting_90_1_2013,76,default,118 +lobby_for_performing_arts_theater_lighting,level_3_lighting_90_1_2013,77,default,296 +lounge_recreation_for_hospital_lighting,level_3_lighting_90_1_2013,80,default,296 +office-enclosed_general_lighting,level_3_lighting_90_1_2013,81,default,355 +office_open_plan_lighting,level_3_lighting_90_1_2013,83,default,414 +automotive_general_lighting,level_3_lighting_90_1_2013,97,default,355 +convention_center_exhibit_space_general_lighting,level_3_lighting_90_1_2013,98,default,431 +library_reading_area_lighting,level_3_lighting_90_1_2013,115,default,592 +library_stacks_lighting,level_3_lighting_90_1_2013,116,default,355 +manufacturing_facility_detailed_manufacturing_area_lighting,level_3_lighting_90_1_2013,117,default,592 +manufacturing_facility_equipment_room_lighting,level_3_lighting_90_1_2013,120,default,237 +manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting,level_3_lighting_90_1_2013,118,default,592 +manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting,level_3_lighting_90_1_2013,119,default,592 +museum_restoration_room_lighting,level_3_lighting_90_1_2013,123,default,592 +post_office_sorting_area_general_lighting,level_3_lighting_90_1_2013,125,default,474 +religious_buildings_fellowship_hall_lighting,level_3_lighting_90_1_2013,127,default,355 +religious_buildings_worship_pulpit_choir_lighting,level_3_lighting_90_1_2013,126,default,355 +retail_mall_concourse_lighting,level_3_lighting_90_1_2013,129,default,403 +transportation_facility_ticket_counter_lighting,level_3_lighting_90_1_2013,138,default,296 +warehouse_storage_area_medium_to_bulky_palletized_items_lighting,level_3_lighting_90_1_2013,141,default,355 +warehouse_storage_area_smaller_hand-carried_items_lighting,level_3_lighting_90_1_2013,142,default,237 +airport_concourse_lighting,level_3_lighting_90_1_2016,137,default,118 +atrium_lighting,level_3_lighting_90_1_2016,33,default,178 +none_lighting,level_3_lighting_90_1_2016,142,default,0 +audience_seating_lighting,level_3_lighting_90_1_2016,36,default,118 +baggage_carousel_lighting,level_3_lighting_90_1_2016,138,default,237 +banking_lighting,level_3_lighting_90_1_2016,45,default,355 +classroom_lecture_training_lighting,level_3_lighting_90_1_2016,47,default,471 +computer_room_lighting,level_3_lighting_90_1_2016,49,default,710 +conference_meeting_multipurpose_lighting,level_3_lighting_90_1_2016,50,default,355 +confinement_cells_lighting,level_3_lighting_90_1_2016,51,default,296 +copy_print_lighting,level_3_lighting_90_1_2016,52,default,178 +corridor_lighting,level_3_lighting_90_1_2016,53,default,178 +courtroom_lighting,level_3_lighting_90_1_2016,57,default,474 +datacenterhighite_lighting,level_3_lighting_90_1_2016,64,default,118 +datacenterlowite_lighting,level_3_lighting_90_1_2016,64,default,118 +dining_lighting,level_3_lighting_90_1_2016,58,default,308 +dressing_room_lighting,level_3_lighting_90_1_2016,127,default,237 +electrical_mechanical_lighting,level_3_lighting_90_1_2016,64,default,118 +emergency_room_lighting,level_3_lighting_90_1_2016,105,default,888 +emergency_vehicle_garage_lighting,level_3_lighting_90_1_2016,65,default,355 +exam_treatment_lighting,level_3_lighting_90_1_2016,105,default,592 +exercise_area_lighting,level_3_lighting_90_1_2016,103,default,474 +exhibit_lighting,level_3_lighting_90_1_2016,121,default,431 +guest_room_lighting,level_3_lighting_90_1_2016,67,default,178 +imaging_lighting,level_3_lighting_90_1_2016,106,default,355 +interior_parking_lighting,level_3_lighting_90_1_2016,84,default,54 +judges_chambers_lighting,level_3_lighting_90_1_2016,57,default,355 +food_preparation_lighting,level_3_lighting_90_1_2016,66,default,538 +laboratory_lighting,level_3_lighting_90_1_2016,68,default,592 +laundry_washing_lighting,level_3_lighting_90_1_2016,70,default,355 +library_lighting,level_3_lighting_90_1_2016,14,default,118 +living_quarters_lighting,level_3_lighting_90_1_2016,99,default,178 +loading_dock_lighting,level_3_lighting_90_1_2016,71,default,355 +lobby_lighting,level_3_lighting_90_1_2016,72,default,296 +locker_room_lighting,level_3_lighting_90_1_2016,78,default,237 +lounge_breakroom_lighting,level_3_lighting_90_1_2016,46,default,178 +manufacturing_lighting,level_3_lighting_90_1_2016,15,default,592 +medical_supply_lighting,level_3_lighting_90_1_2016,107,default,355 +multifamily_lighting,level_3_lighting_90_1_2016,17,default,178 +nursery_lighting,level_3_lighting_90_1_2016,109,default,355 +nurses_station_lighting,level_3_lighting_90_1_2016,108,default,355 +office_lighting,level_3_lighting_90_1_2016,19,default,414 +office_enclosed_lighting,level_3_lighting_90_1_2016,81,default,355 +operating_room_lighting,level_3_lighting_90_1_2016,110,default,1184 +patient_room_lighting,level_3_lighting_90_1_2016,111,default,355 +pharmacy_lighting,level_3_lighting_90_1_2016,107,default,888 +physical_therapy_lighting,level_3_lighting_90_1_2016,112,default,474 +playing_area_lighting,level_3_lighting_90_1_2016,104,default,592 +post_office_lighting,level_3_lighting_90_1_2016,24,default,237 +recovery_lighting,level_3_lighting_90_1_2016,113,default,592 +recreation_common_living_lighting,level_3_lighting_90_1_2016,79,default,323 +restroom_lighting,level_3_lighting_90_1_2016,86,default,178 +retail_sales_lighting,level_3_lighting_90_1_2016,88,default,474 +sleeping_quarters_lighting,level_3_lighting_90_1_2016,102,default,59 +sports_arena_lighting,level_3_lighting_90_1_2016,28,default,1184 +stairwell_lighting,level_3_lighting_90_1_2016,91,default,118 +storage_lighting,level_3_lighting_90_1_2016,94,default,118 +transportation_lighting,level_3_lighting_90_1_2016,30,default,237 +vehicular_maintenance_lighting,level_3_lighting_90_1_2016,95,default,355 +workshop_lighting,level_3_lighting_90_1_2016,32,default,592 +worship_lighting,level_3_lighting_90_1_2016,25,default,355 +ba_automotive_facility_lighting,level_3_lighting_90_1_2016,1,default,355 +ba_convention_center_lighting,level_3_lighting_90_1_2016,2,default,118 +ba_courthouse_lighting,level_3_lighting_90_1_2016,3,default,474 +ba_dining_bar_lounge_leisure_lighting,level_3_lighting_90_1_2016,4,default,118 +ba_dining_cafeteria_fast_food_lighting,level_3_lighting_90_1_2016,5,default,237 +ba_dining_family_lighting,level_3_lighting_90_1_2016,6,default,237 +ba_dormitory_lighting,level_3_lighting_90_1_2016,7,default,178 +ba_exercise_center_lighting,level_3_lighting_90_1_2016,8,default,237 +ba_fire_station_lighting,level_3_lighting_90_1_2016,9,default,118 +ba_gymnasium_lighting,level_3_lighting_90_1_2016,10,default,237 +ba_health-care_clinic_lighting,level_3_lighting_90_1_2016,11,default,592 +ba_hospital_lighting,level_3_lighting_90_1_2016,12,default,592 +ba_hotel_motel_lighting,level_3_lighting_90_1_2016,13,default,178 +ba_motion_picture_theater_lighting,level_3_lighting_90_1_2016,16,default,118 +ba_museum_lighting,level_3_lighting_90_1_2016,18,default,118 +ba_parking_garage_lighting,level_3_lighting_90_1_2016,20,default,54 +ba_penitentiary_lighting,level_3_lighting_90_1_2016,21,default,296 +ba_performing_arts_theater_lighting,level_3_lighting_90_1_2016,22,default,426 +ba_police_station_lighting,level_3_lighting_90_1_2016,23,default,118 +ba_school_university_lighting,level_3_lighting_90_1_2016,27,default,471 +ba_town_hall_lighting,level_3_lighting_90_1_2016,29,default,355 +ba_retail_lighting,level_3_lighting_90_1_2016,26,default,474 +ba_warehouse_lighting,level_3_lighting_90_1_2016,31,default,118 +audience_seating_area_for_gymnasium_lighting,level_3_lighting_90_1_2016,39,default,118 +audience_seating_area_for_motion_picture_theater_lighting,level_3_lighting_90_1_2016,40,default,118 +audience_seating_area_for_penitentiary_lighting,level_3_lighting_90_1_2016,41,default,355 +audience_seating_area_for_performing_arts_theater_lighting,level_3_lighting_90_1_2016,42,default,426 +audience_seating_area_for_religious_buildings_lighting,level_3_lighting_90_1_2016,43,default,118 +audience_seating_area_for_sports_arena_lighting,level_3_lighting_90_1_2016,44,default,118 +classroom_lecture_training_for_penitentiary_lighting,level_3_lighting_90_1_2016,48,default,471 +corridor_transition_for_hospital_lighting,level_3_lighting_90_1_2016,55,default,355 +dining_area_for_penitentiary_lighting,level_3_lighting_90_1_2016,61,default,178 +dining_bar_lounge_leisure_general_lighting,level_3_lighting_90_1_2016,4,default,118 +dining_cafeteria_fast_food_general_lighting,level_3_lighting_90_1_2016,5,default,237 +dining_area_for_family_dining_lighting,level_3_lighting_90_1_2016,62,default,237 +lobby_for_hotel_lighting,level_3_lighting_90_1_2016,75,default,178 +lobby_for_motion_picture_theater_lighting,level_3_lighting_90_1_2016,76,default,118 +lobby_for_performing_arts_theater_lighting,level_3_lighting_90_1_2016,77,default,296 +lounge_recreation_for_hospital_lighting,level_3_lighting_90_1_2016,80,default,296 +office-enclosed_general_lighting,level_3_lighting_90_1_2016,81,default,355 +office_open_plan_lighting,level_3_lighting_90_1_2016,83,default,414 +automotive_general_lighting,level_3_lighting_90_1_2016,97,default,355 +convention_center_exhibit_space_general_lighting,level_3_lighting_90_1_2016,98,default,431 +library_reading_area_lighting,level_3_lighting_90_1_2016,114,default,592 +library_stacks_lighting,level_3_lighting_90_1_2016,115,default,355 +manufacturing_facility_detailed_manufacturing_area_lighting,level_3_lighting_90_1_2016,116,default,592 +manufacturing_facility_equipment_room_lighting,level_3_lighting_90_1_2016,117,default,237 +manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting,level_3_lighting_90_1_2016,119,default,592 +manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting,level_3_lighting_90_1_2016,120,default,592 +museum_restoration_room_lighting,level_3_lighting_90_1_2016,122,default,592 +post_office_sorting_area_general_lighting,level_3_lighting_90_1_2016,124,default,474 +religious_buildings_fellowship_hall_lighting,level_3_lighting_90_1_2016,125,default,355 +religious_buildings_worship_pulpit_choir_lighting,level_3_lighting_90_1_2016,126,default,355 +retail_mall_concourse_lighting,level_3_lighting_90_1_2016,128,default,403 +transportation_facility_ticket_counter_lighting,level_3_lighting_90_1_2016,139,default,296 +warehouse_storage_area_medium_to_bulky_palletized_items_lighting,level_3_lighting_90_1_2016,140,default,355 +warehouse_storage_area_smaller_hand-carried_items_lighting,level_3_lighting_90_1_2016,141,default,237 +airport_concourse_lighting,level_3_lighting_90_1_2019,134,default,118 +atrium_lighting,level_3_lighting_90_1_2019,33,default,178 +none_lighting,level_3_lighting_90_1_2019,139,default,0 +audience_seating_lighting,level_3_lighting_90_1_2019,36,default,118 +baggage_carousel_lighting,level_3_lighting_90_1_2019,135,default,237 +banking_lighting,level_3_lighting_90_1_2019,44,default,355 +classroom_lecture_training_lighting,level_3_lighting_90_1_2019,46,default,471 +computer_room_lighting,level_3_lighting_90_1_2019,48,default,710 +conference_meeting_multipurpose_lighting,level_3_lighting_90_1_2019,49,default,355 +confinement_cells_lighting,level_3_lighting_90_1_2019,50,default,296 +copy_print_lighting,level_3_lighting_90_1_2019,51,default,178 +corridor_lighting,level_3_lighting_90_1_2019,52,default,178 +courtroom_lighting,level_3_lighting_90_1_2019,55,default,474 +datacenterhighite_lighting,level_3_lighting_90_1_2019,62,default,118 +datacenterlowite_lighting,level_3_lighting_90_1_2019,62,default,118 +dining_lighting,level_3_lighting_90_1_2019,56,default,308 +dressing_room_lighting,level_3_lighting_90_1_2019,124,default,237 +electrical_mechanical_lighting,level_3_lighting_90_1_2019,62,default,118 +emergency_room_lighting,level_3_lighting_90_1_2019,102,default,888 +emergency_vehicle_garage_lighting,level_3_lighting_90_1_2019,63,default,355 +exam_treatment_lighting,level_3_lighting_90_1_2019,102,default,592 +exercise_area_lighting,level_3_lighting_90_1_2019,100,default,474 +exhibit_lighting,level_3_lighting_90_1_2019,118,default,431 +guest_room_lighting,level_3_lighting_90_1_2019,65,default,178 +imaging_lighting,level_3_lighting_90_1_2019,103,default,355 +interior_parking_lighting,level_3_lighting_90_1_2019,82,default,54 +judges_chambers_lighting,level_3_lighting_90_1_2019,55,default,355 +food_preparation_lighting,level_3_lighting_90_1_2019,64,default,538 +laboratory_lighting,level_3_lighting_90_1_2019,66,default,592 +laundry_washing_lighting,level_3_lighting_90_1_2019,68,default,355 +library_lighting,level_3_lighting_90_1_2019,14,default,118 +living_quarters_lighting,level_3_lighting_90_1_2019,96,default,178 +loading_dock_lighting,level_3_lighting_90_1_2019,69,default,355 +lobby_lighting,level_3_lighting_90_1_2019,70,default,296 +locker_room_lighting,level_3_lighting_90_1_2019,76,default,237 +lounge_breakroom_lighting,level_3_lighting_90_1_2019,45,default,178 +manufacturing_lighting,level_3_lighting_90_1_2019,15,default,592 +medical_supply_lighting,level_3_lighting_90_1_2019,104,default,355 +multifamily_lighting,level_3_lighting_90_1_2019,17,default,178 +nursery_lighting,level_3_lighting_90_1_2019,105,default,355 +nurses_station_lighting,level_3_lighting_90_1_2019,106,default,355 +office_lighting,level_3_lighting_90_1_2019,19,default,414 +office_enclosed_lighting,level_3_lighting_90_1_2019,79,default,355 +operating_room_lighting,level_3_lighting_90_1_2019,107,default,1184 +patient_room_lighting,level_3_lighting_90_1_2019,108,default,355 +pharmacy_lighting,level_3_lighting_90_1_2019,104,default,888 +physical_therapy_lighting,level_3_lighting_90_1_2019,109,default,474 +playing_area_lighting,level_3_lighting_90_1_2019,101,default,592 +post_office_lighting,level_3_lighting_90_1_2019,24,default,237 +recovery_lighting,level_3_lighting_90_1_2019,110,default,592 +recreation_common_living_lighting,level_3_lighting_90_1_2019,77,default,323 +restroom_lighting,level_3_lighting_90_1_2019,84,default,178 +retail_sales_lighting,level_3_lighting_90_1_2019,86,default,474 +sleeping_quarters_lighting,level_3_lighting_90_1_2019,99,default,59 +sports_arena_lighting,level_3_lighting_90_1_2019,28,default,1184 +stairwell_lighting,level_3_lighting_90_1_2019,89,default,118 +storage_lighting,level_3_lighting_90_1_2019,91,default,118 +transportation_lighting,level_3_lighting_90_1_2019,30,default,237 +vehicular_maintenance_lighting,level_3_lighting_90_1_2019,92,default,355 +workshop_lighting,level_3_lighting_90_1_2019,32,default,592 +worship_lighting,level_3_lighting_90_1_2019,25,default,355 +ba_automotive_facility_lighting,level_3_lighting_90_1_2019,1,default,355 +ba_convention_center_lighting,level_3_lighting_90_1_2019,2,default,118 +ba_courthouse_lighting,level_3_lighting_90_1_2019,3,default,474 +ba_dining_bar_lounge_leisure_lighting,level_3_lighting_90_1_2019,4,default,118 +ba_dining_cafeteria_fast_food_lighting,level_3_lighting_90_1_2019,5,default,237 +ba_dining_family_lighting,level_3_lighting_90_1_2019,6,default,237 +ba_dormitory_lighting,level_3_lighting_90_1_2019,7,default,178 +ba_exercise_center_lighting,level_3_lighting_90_1_2019,8,default,237 +ba_fire_station_lighting,level_3_lighting_90_1_2019,9,default,118 +ba_gymnasium_lighting,level_3_lighting_90_1_2019,10,default,237 +ba_health-care_clinic_lighting,level_3_lighting_90_1_2019,11,default,592 +ba_hospital_lighting,level_3_lighting_90_1_2019,12,default,592 +ba_hotel_motel_lighting,level_3_lighting_90_1_2019,13,default,178 +ba_motion_picture_theater_lighting,level_3_lighting_90_1_2019,16,default,118 +ba_museum_lighting,level_3_lighting_90_1_2019,18,default,118 +ba_parking_garage_lighting,level_3_lighting_90_1_2019,20,default,54 +ba_penitentiary_lighting,level_3_lighting_90_1_2019,21,default,296 +ba_performing_arts_theater_lighting,level_3_lighting_90_1_2019,22,default,426 +ba_police_station_lighting,level_3_lighting_90_1_2019,23,default,118 +ba_school_university_lighting,level_3_lighting_90_1_2019,27,default,471 +ba_town_hall_lighting,level_3_lighting_90_1_2019,29,default,355 +ba_retail_lighting,level_3_lighting_90_1_2019,26,default,474 +ba_warehouse_lighting,level_3_lighting_90_1_2019,31,default,118 +audience_seating_area_for_gymnasium_lighting,level_3_lighting_90_1_2019,38,default,118 +audience_seating_area_for_motion_picture_theater_lighting,level_3_lighting_90_1_2019,39,default,118 +audience_seating_area_for_penitentiary_lighting,level_3_lighting_90_1_2019,40,default,355 +audience_seating_area_for_performing_arts_theater_lighting,level_3_lighting_90_1_2019,41,default,426 +audience_seating_area_for_religious_buildings_lighting,level_3_lighting_90_1_2019,42,default,118 +audience_seating_area_for_sports_arena_lighting,level_3_lighting_90_1_2019,43,default,118 +classroom_lecture_training_for_penitentiary_lighting,level_3_lighting_90_1_2019,47,default,471 +corridor_transition_for_hospital_lighting,level_3_lighting_90_1_2019,54,default,355 +dining_area_for_penitentiary_lighting,level_3_lighting_90_1_2019,61,default,178 +dining_bar_lounge_leisure_general_lighting,level_3_lighting_90_1_2019,57,default,118 +dining_cafeteria_fast_food_general_lighting,level_3_lighting_90_1_2019,58,default,237 +dining_area_for_family_dining_lighting,level_3_lighting_90_1_2019,60,default,237 +lobby_for_hotel_lighting,level_3_lighting_90_1_2019,73,default,178 +lobby_for_motion_picture_theater_lighting,level_3_lighting_90_1_2019,74,default,118 +lobby_for_performing_arts_theater_lighting,level_3_lighting_90_1_2019,75,default,296 +lounge_recreation_for_hospital_lighting,level_3_lighting_90_1_2019,78,default,296 +office-enclosed_general_lighting,level_3_lighting_90_1_2019,80,default,355 +office_open_plan_lighting,level_3_lighting_90_1_2019,81,default,414 +automotive_general_lighting,level_3_lighting_90_1_2019,94,default,355 +convention_center_exhibit_space_general_lighting,level_3_lighting_90_1_2019,95,default,431 +library_reading_area_lighting,level_3_lighting_90_1_2019,111,default,592 +library_stacks_lighting,level_3_lighting_90_1_2019,112,default,355 +manufacturing_facility_detailed_manufacturing_area_lighting,level_3_lighting_90_1_2019,113,default,592 +manufacturing_facility_equipment_room_lighting,level_3_lighting_90_1_2019,114,default,237 +manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting,level_3_lighting_90_1_2019,116,default,592 +manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting,level_3_lighting_90_1_2019,117,default,592 +museum_restoration_room_lighting,level_3_lighting_90_1_2019,119,default,592 +post_office_sorting_area_general_lighting,level_3_lighting_90_1_2019,121,default,474 +religious_buildings_fellowship_hall_lighting,level_3_lighting_90_1_2019,122,default,355 +religious_buildings_worship_pulpit_choir_lighting,level_3_lighting_90_1_2019,123,default,355 +retail_mall_concourse_lighting,level_3_lighting_90_1_2019,125,default,403 +transportation_facility_ticket_counter_lighting,level_3_lighting_90_1_2019,136,default,296 +warehouse_storage_area_medium_to_bulky_palletized_items_lighting,level_3_lighting_90_1_2019,137,default,355 +warehouse_storage_area_smaller_hand-carried_items_lighting,level_3_lighting_90_1_2019,138,default,237 diff --git a/data/openstudio_standards_data/database_files/level_2_lighting_space_types.json b/data/openstudio_standards_data/database_files/level_2_lighting_space_types.json index a66c4aa138..ca2e6533ee 100644 --- a/data/openstudio_standards_data/database_files/level_2_lighting_space_types.json +++ b/data/openstudio_standards_data/database_files/level_2_lighting_space_types.json @@ -1,1432 +1,4958 @@ [ { - "lighting_space_type_name": "bam_automotive_facility", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 1 + "lighting_space_type_name": "airport_concourse_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 122, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "bam_convention_center", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 2 + "lighting_space_type_name": "atrium_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 36, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "bam_courthouse", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 3 + "lighting_space_type_name": "none_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 126, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 0 }, { - "lighting_space_type_name": "bam_dinin_bar_lounge_leisure", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 4 + "lighting_space_type_name": "audience_seating_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 46, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "bam_dining_cafeteria_fast_food", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 5 + "lighting_space_type_name": "baggage_carousel_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 121, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "bam_dining_family", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 6 + "lighting_space_type_name": "banking_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 77, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "bam_dormitory", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 7 + "lighting_space_type_name": "classroom_lecture_training_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 48, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 471 }, { - "lighting_space_type_name": "bam_exercise_center", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 8 + "lighting_space_type_name": "computer_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 48, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 710 }, { - "lighting_space_type_name": "bam_fire_station", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 23 + "lighting_space_type_name": "conference_meeting_multipurpose_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 49, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "bam_gymnasium", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 9 + "lighting_space_type_name": "confinement_cells_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 79, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 }, { - "lighting_space_type_name": "bam_healthcare_clinic", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 10 + "lighting_space_type_name": "copy_print_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 49, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "bam_hospital", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 11 + "lighting_space_type_name": "corridor_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 52, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "bam_hotel", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 12 + "lighting_space_type_name": "courtroom_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 80, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 }, { - "lighting_space_type_name": "bam_library", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 13 + "lighting_space_type_name": "datacenterhighite_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 60, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "bam_manufacturing_facility", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 14 + "lighting_space_type_name": "datacenterlowite_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 60, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "bam_motel", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 15 + "lighting_space_type_name": "dining_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 58, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 308 }, { - "lighting_space_type_name": "bam_motion_picture_theater", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 16 + "lighting_space_type_name": "dressing_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 59, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "bam_multifamily", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 17 + "lighting_space_type_name": "electrical_mechanical_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 60, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "bam_museum", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 18 + "lighting_space_type_name": "emergency_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 87, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 888 }, { - "lighting_space_type_name": "bam_office", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 19 + "lighting_space_type_name": "emergency_vehicle_garage_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 83, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "bam_parking_garage", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 20 + "lighting_space_type_name": "exam_treatment_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 88, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "bam_penitentiary", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 21 + "lighting_space_type_name": "exercise_area_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 85, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 }, { - "lighting_space_type_name": "bam_performing_arts_theater", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 22 + "lighting_space_type_name": "exhibit_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 108, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 431 }, { - "lighting_space_type_name": "bam_police_station", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 23 + "lighting_space_type_name": "guest_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 99, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "bam_post_office", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 24 + "lighting_space_type_name": "imaging_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 97, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "bam_religious_facility", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 25 + "lighting_space_type_name": "interior_parking_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 110, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 54 }, { - "lighting_space_type_name": "bam_retail", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 26 + "lighting_space_type_name": "judges_chambers_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 81, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "bam_school_university", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 27 + "lighting_space_type_name": "food_preparation_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 61, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 538 }, { - "lighting_space_type_name": "bam_sports_arena", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 28 + "lighting_space_type_name": "laboratory_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 64, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "bam_town_hall", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 29 + "lighting_space_type_name": "laundry_washing_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 89, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "bam_transportation", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 30 + "lighting_space_type_name": "library_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 13, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "bam_warehouse", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 31 + "lighting_space_type_name": "living_quarters_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 82, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "bam_workshop", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 32 + "lighting_space_type_name": "loading_dock_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 30, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "office_enclosed_small", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 33 + "lighting_space_type_name": "lobby_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 68, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 }, { - "lighting_space_type_name": "office_enclosed_large", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 33 + "lighting_space_type_name": "locker_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 59, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "office_open", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 34 + "lighting_space_type_name": "lounge_breakroom_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 70, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "conference_meeting_multipurpose", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 35 + "lighting_space_type_name": "manufacturing_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 14, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "classroom_lecture_training_general", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 36 + "lighting_space_type_name": "medical_supply_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 90, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "classroom_lecture_training_penitentiary", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 37 + "lighting_space_type_name": "multifamily_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 17, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "lobby_general", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 38 + "lighting_space_type_name": "nursery_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 92, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "lobby_hotel", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 39 + "lighting_space_type_name": "nurses_station_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 91, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "lobby_performing_arts_theater", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 40 + "lighting_space_type_name": "office_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 19, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 414 }, { - "lighting_space_type_name": "lobby_motion_picture_theater", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 41 + "lighting_space_type_name": "office_enclosed_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 71, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "lobby_visually_impaired", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 38 + "lighting_space_type_name": "operating_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 93, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 1184 }, { - "lighting_space_type_name": "lobby_elevator", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 38 + "lighting_space_type_name": "patient_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 94, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "audience_seating_general", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 42 + "lighting_space_type_name": "pharmacy_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 95, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 888 }, { - "lighting_space_type_name": "audience_seating_gymnasium", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 43 + "lighting_space_type_name": "physical_therapy_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 96, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 }, { - "lighting_space_type_name": "audience_seating_exercise_center", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 44 + "lighting_space_type_name": "playing_area_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 86, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "audience_seating_convention_center", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 45 + "lighting_space_type_name": "post_office_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 24, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "audience_seating_penitentiary", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 46 + "lighting_space_type_name": "recovery_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 98, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "audience_seating_religious_facility", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 47 + "lighting_space_type_name": "recreation_common_living_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 70, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 323 }, { - "lighting_space_type_name": "audience_seating_sports_arena", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 48 + "lighting_space_type_name": "restroom_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 73, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "audience_seating_performing_arts_theater", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 49 + "lighting_space_type_name": "retail_sales_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 117, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 }, { - "lighting_space_type_name": "audience_seating_motion_picture_theater", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 50 + "lighting_space_type_name": "sleeping_quarters_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 84, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 59 }, { - "lighting_space_type_name": "audience_seating_transportation", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 51 + "lighting_space_type_name": "sports_arena_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 28, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 1184 }, { - "lighting_space_type_name": "audience_seating_auditorium", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 42 + "lighting_space_type_name": "stairwell_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 74, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "atrium_first_three_floor", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 52 + "lighting_space_type_name": "storage_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 34, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "atrium_each_additional_floor", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 53 + "lighting_space_type_name": "transportation_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 30, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "lounge_breakroom_general", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 54 + "lighting_space_type_name": "vehicular_maintenance_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 76, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "lounge_breakroom_healthcare_facility", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 55 + "lighting_space_type_name": "workshop_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 32, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "dining_general", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 56 + "lighting_space_type_name": "worship_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 25, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "dining_penitentiary", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 57 + "lighting_space_type_name": "ba_automotive_facility_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 1, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "dining_hotel", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 58 + "lighting_space_type_name": "ba_convention_center_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 2, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "dining_motel", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 59 + "lighting_space_type_name": "ba_courthouse_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 3, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 }, { - "lighting_space_type_name": "dining_bar_lounge_leisure", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 60 + "lighting_space_type_name": "ba_dining_bar_lounge_leisure_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 4, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "dining_family", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 61 + "lighting_space_type_name": "ba_dining_cafeteria_fast_food_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 5, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "dining_cafeteria_fast_food", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 56 + "lighting_space_type_name": "ba_dining_family_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 6, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "dining_visually_impaired", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 56 + "lighting_space_type_name": "ba_dormitory_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 7, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "kitchen", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 62 + "lighting_space_type_name": "ba_exercise_center_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 8, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "laboratory_classroom", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 63 + "lighting_space_type_name": "ba_fire_station_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 23, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "laboratory_all_other", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 63 + "lighting_space_type_name": "ba_gymnasium_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 9, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "restroom_visually_impaired", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 64 + "lighting_space_type_name": "ba_health-care_clinic_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 10, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "restroom_all_other", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 64 + "lighting_space_type_name": "ba_hospital_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 11, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "performing_arts_dressing_room", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 65 + "lighting_space_type_name": "ba_hotel_motel_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 12, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "corridor_general", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 66 + "lighting_space_type_name": "ba_motion_picture_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 16, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "corridor_hospital", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 67 + "lighting_space_type_name": "ba_museum_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 18, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "corridor_manufacturing_facility", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 68 + "lighting_space_type_name": "ba_parking_garage_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 20, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 54 }, { - "lighting_space_type_name": "corridor_visually_impaired", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 66 + "lighting_space_type_name": "ba_penitentiary_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 21, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 }, { - "lighting_space_type_name": "stairway", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 69 + "lighting_space_type_name": "ba_performing_arts_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 22, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 426 }, { - "lighting_space_type_name": "stairwell", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 69 + "lighting_space_type_name": "ba_police_station_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 23, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "storage_ all_other_small", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 70 + "lighting_space_type_name": "ba_school_university_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 27, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 471 }, { - "lighting_space_type_name": "storage_ all_other_large", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 70 + "lighting_space_type_name": "ba_town_hall_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 29, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "storage_hospital_small", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 71 + "lighting_space_type_name": "ba_retail_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 26, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 }, { - "lighting_space_type_name": "storage_hospital_large", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 71 + "lighting_space_type_name": "ba_warehouse_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 31, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "storage_inactive", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 72 + "lighting_space_type_name": "audience_seating_area_for_gymnasium_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 39, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "storage_inactive_museum", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 73 + "lighting_space_type_name": "audience_seating_area_for_motion_picture_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 40, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "electrical_mechanical", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 74 + "lighting_space_type_name": "audience_seating_area_for_penitentiary_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 41, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "workshop", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 75 + "lighting_space_type_name": "audience_seating_area_for_performing_arts_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 42, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 426 }, { - "lighting_space_type_name": "gymnasium_playing_area", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 76 + "lighting_space_type_name": "audience_seating_area_for_religious_buildings_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 43, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "gymnasium_exercise_area", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 77 + "lighting_space_type_name": "audience_seating_area_for_sports_arena_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 44, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "courtroom", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 78 + "lighting_space_type_name": "classroom_lecture_training_for_penitentiary_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 47, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 471 }, { - "lighting_space_type_name": "confinement_cells", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 79 + "lighting_space_type_name": "corridor_transition_for_hospital_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 50, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "judges_chambers", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 80 + "lighting_space_type_name": "dining_area_for_penitentiary_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 57, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "emergency_vehicle_garage", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 81 + "lighting_space_type_name": "dining_bar_lounge_leisure_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 4, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "firestation_sleeping_quarters", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 82 + "lighting_space_type_name": "dining_cafeteria_fast_food_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 5, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "post_office_sorting_area", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 83 + "lighting_space_type_name": "dining_area_for_family_dining_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 54, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "exhibit_convention_center", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 84 + "lighting_space_type_name": "lobby_for_hotel_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 65, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "library_cataloging", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 85 + "lighting_space_type_name": "lobby_for_motion_picture_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 66, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "library_stacks", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 86 + "lighting_space_type_name": "lobby_for_performing_arts_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 67, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 }, { - "lighting_space_type_name": "library_reading", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 87 + "lighting_space_type_name": "lounge_recreation_for_hospital_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 69, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 }, { - "lighting_space_type_name": "emergency_room", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 88 + "lighting_space_type_name": "office-enclosed_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 71, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "recovery", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 89 + "lighting_space_type_name": "office_open_plan_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 72, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 414 }, { - "lighting_space_type_name": "nurses_station", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 90 + "lighting_space_type_name": "automotive_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 76, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "exam_treatment", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 91 + "lighting_space_type_name": "convention_center_exhibit_space_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 78, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 431 }, { - "lighting_space_type_name": "pharmacy", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 92 + "lighting_space_type_name": "library_reading_area_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 101, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "patient_room", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 93 + "lighting_space_type_name": "library_stacks_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 102, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "operating_room", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 94 + "lighting_space_type_name": "manufacturing_facility_detailed_manufacturing_area_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 104, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "nursery", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 95 + "lighting_space_type_name": "manufacturing_facility_equipment_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 105, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "medical_supply", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 96 + "lighting_space_type_name": "manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 106, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "physical_therapy", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 97 + "lighting_space_type_name": "manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 107, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "imaging", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 98 + "lighting_space_type_name": "museum_restoration_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 109, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "laundry_washing", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 99 + "lighting_space_type_name": "post_office_sorting_area_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 111, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 }, { - "lighting_space_type_name": "automotive", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 100 + "lighting_space_type_name": "religious_buildings_fellowship_hall_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 112, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "manufacturing_low_bay", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 101 + "lighting_space_type_name": "religious_buildings_worship_pulpit_choir_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 113, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "manufacturing_high_bay", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 102 + "lighting_space_type_name": "retail_mall_concourse_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 114, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 403 }, { - "lighting_space_type_name": "detailed_manufacuring", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 103 + "lighting_space_type_name": "transportation_facility_ticket_counter_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 123, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 }, { - "lighting_space_type_name": "manufacturing_equipment_room", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 104 + "lighting_space_type_name": "warehouse_storage_area_medium_to_bulky_palletized_items_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 125, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "manufacturing_control", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 105 + "lighting_space_type_name": "warehouse_storage_area_smaller_hand-carried_items_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", + "level_3_lighting_code_definition_id": 124, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "guest_room", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 106 + "lighting_space_type_name": "airport_concourse_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 125, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "dormitory_living_quarters", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 107 + "lighting_space_type_name": "atrium_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 36, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "museum_exhibit_area", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 108 + "lighting_space_type_name": "none_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 129, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 0 }, { - "lighting_space_type_name": "museum_restoration", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 109 + "lighting_space_type_name": "audience_seating_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 46, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "banking_activity", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 110 + "lighting_space_type_name": "baggage_carousel_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 124, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "worship_pulpit_choir_area", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 111 + "lighting_space_type_name": "banking_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 78, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "fellowship_hall_religious_facility", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 112 + "lighting_space_type_name": "classroom_lecture_training_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 48, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 471 }, { - "lighting_space_type_name": "sales", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 113 + "lighting_space_type_name": "computer_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 48, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 710 }, { - "lighting_space_type_name": "retail_mall_concourse", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 114 + "lighting_space_type_name": "conference_meeting_multipurpose_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 49, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "sports_arena_ring_sports_area", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 115 + "lighting_space_type_name": "confinement_cells_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 80, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 }, { - "lighting_space_type_name": "sports_arena_court_sports_area", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 116 + "lighting_space_type_name": "copy_print_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 49, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "sports_arena_indoor_playing_field", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 117 + "lighting_space_type_name": "corridor_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 52, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "warehouse_bulk_storage", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 119 + "lighting_space_type_name": "courtroom_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 81, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 }, { - "lighting_space_type_name": "parking_area_interior", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 120 + "lighting_space_type_name": "datacenterhighite_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 60, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "airport_concourse", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 121 + "lighting_space_type_name": "datacenterlowite_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 60, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "baggage_carousel", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 122 + "lighting_space_type_name": "dining_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 58, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 308 }, { - "lighting_space_type_name": "transportation_ticket_counter", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 123 + "lighting_space_type_name": "dressing_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 59, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "sales_display_type_1", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 124 + "lighting_space_type_name": "electrical_mechanical_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 60, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "sales_display_type_2", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 124 + "lighting_space_type_name": "emergency_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 88, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 888 }, { - "lighting_space_type_name": "sales_display_type_3", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 125 + "lighting_space_type_name": "emergency_vehicle_garage_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 84, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "sales_display_type_4", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2004", - "level_3_lighting_definition_id": 125 + "lighting_space_type_name": "exam_treatment_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 89, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "bam_automotive_facility", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 1 + "lighting_space_type_name": "exercise_area_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 86, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 }, { - "lighting_space_type_name": "bam_convention_center", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 2 + "lighting_space_type_name": "exhibit_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 109, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 431 }, { - "lighting_space_type_name": "bam_courthouse", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 3 + "lighting_space_type_name": "guest_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 100, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "bam_dinin_bar_lounge_leisure", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 4 + "lighting_space_type_name": "imaging_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 98, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "bam_dining_cafeteria_fast_food", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 5 + "lighting_space_type_name": "interior_parking_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 111, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 54 }, { - "lighting_space_type_name": "bam_dining_family", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 6 + "lighting_space_type_name": "judges_chambers_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 82, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "bam_dormitory", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 7 + "lighting_space_type_name": "food_preparation_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 61, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 538 }, { - "lighting_space_type_name": "bam_exercise_center", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 8 + "lighting_space_type_name": "laboratory_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 64, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "bam_fire_station", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 9 + "lighting_space_type_name": "laundry_washing_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 90, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "bam_gymnasium", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 10 + "lighting_space_type_name": "library_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 13, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "bam_healthcare_clinic", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 11 + "lighting_space_type_name": "living_quarters_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 83, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "bam_hospital", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 12 + "lighting_space_type_name": "loading_dock_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 30, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "bam_hotel", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 13 + "lighting_space_type_name": "lobby_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 68, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 }, { - "lighting_space_type_name": "bam_library", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 14 + "lighting_space_type_name": "locker_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 59, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "bam_manufacturing_facility", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 15 + "lighting_space_type_name": "lounge_breakroom_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 70, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "bam_motel", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 13 + "lighting_space_type_name": "manufacturing_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 14, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "bam_motion_picture_theater", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 16 + "lighting_space_type_name": "medical_supply_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 91, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "bam_multifamily", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 17 + "lighting_space_type_name": "multifamily_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 17, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "bam_museum", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 18 + "lighting_space_type_name": "nursery_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 93, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "bam_office", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 19 + "lighting_space_type_name": "nurses_station_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 92, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "bam_parking_garage", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 20 + "lighting_space_type_name": "office_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 19, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 414 }, { - "lighting_space_type_name": "bam_penitentiary", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 21 + "lighting_space_type_name": "office_enclosed_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 71, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "bam_performing_arts_theater", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 22 + "lighting_space_type_name": "operating_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 94, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 1184 }, { - "lighting_space_type_name": "bam_police_station", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 23 + "lighting_space_type_name": "patient_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 95, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "bam_post_office", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 24 + "lighting_space_type_name": "pharmacy_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 96, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 888 }, { - "lighting_space_type_name": "bam_religious_facility", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 25 + "lighting_space_type_name": "physical_therapy_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 97, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 }, { - "lighting_space_type_name": "bam_retail", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 26 + "lighting_space_type_name": "playing_area_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 87, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "bam_school_university", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 27 + "lighting_space_type_name": "post_office_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 24, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "bam_sports_arena", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 28 + "lighting_space_type_name": "recovery_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 99, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "bam_town_hall", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 29 + "lighting_space_type_name": "recreation_common_living_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 70, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 323 }, { - "lighting_space_type_name": "bam_transportation", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 30 + "lighting_space_type_name": "restroom_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 73, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "bam_warehouse", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 31 + "lighting_space_type_name": "retail_sales_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 120, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 }, { - "lighting_space_type_name": "bam_workshop", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 32 + "lighting_space_type_name": "sleeping_quarters_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 85, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 59 }, { - "lighting_space_type_name": "office_enclosed_small", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 79 + "lighting_space_type_name": "sports_arena_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 28, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 1184 }, { - "lighting_space_type_name": "office_enclosed_large", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 80 + "lighting_space_type_name": "stairwell_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 75, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "office_open", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 81 + "lighting_space_type_name": "storage_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 34, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "conference_meeting_multipurpose", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 48 + "lighting_space_type_name": "transportation_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 30, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "classroom_lecture_training_general", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 47 + "lighting_space_type_name": "vehicular_maintenance_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 77, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "classroom_lecture_training_penitentiary", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 46 + "lighting_space_type_name": "workshop_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 32, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "lobby_general", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 75 + "lighting_space_type_name": "worship_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 25, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "lobby_hotel", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 72 + "lighting_space_type_name": "ba_automotive_facility_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 1, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "lobby_performing_arts_theater", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 74 + "lighting_space_type_name": "ba_convention_center_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 2, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "lobby_motion_picture_theater", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 73 + "lighting_space_type_name": "ba_courthouse_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 3, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 }, { - "lighting_space_type_name": "lobby_visually_impaired", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 70 + "lighting_space_type_name": "ba_dining_bar_lounge_leisure_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 4, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "lobby_elevator", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 71 + "lighting_space_type_name": "ba_dining_cafeteria_fast_food_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 5, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "audience_seating_general", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 43 + "lighting_space_type_name": "ba_dining_family_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 6, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "audience_seating_gymnasium", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 37 + "lighting_space_type_name": "ba_dormitory_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 7, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "audience_seating_exercise_center", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 43 + "lighting_space_type_name": "ba_exercise_center_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 8, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "audience_seating_convention_center", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 43 + "lighting_space_type_name": "ba_fire_station_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 23, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "audience_seating_penitentiary", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 39 + "lighting_space_type_name": "ba_gymnasium_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 9, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "audience_seating_religious_facility", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 41 + "lighting_space_type_name": "ba_health-care_clinic_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 10, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "audience_seating_sports_arena", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 42 + "lighting_space_type_name": "ba_hospital_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 11, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "audience_seating_performing_arts_theater", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 40 + "lighting_space_type_name": "ba_hotel_motel_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 12, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "audience_seating_motion_picture_theater", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 38 + "lighting_space_type_name": "ba_motion_picture_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 16, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "audience_seating_transportation", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 43 + "lighting_space_type_name": "ba_museum_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 18, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "audience_seating_auditorium", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 36 + "lighting_space_type_name": "ba_parking_garage_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 20, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 54 }, { - "lighting_space_type_name": "atrium_low", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 33 + "lighting_space_type_name": "ba_penitentiary_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 21, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 }, { - "lighting_space_type_name": "atrium_medium", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 34 + "lighting_space_type_name": "ba_performing_arts_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 22, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 426 }, { - "lighting_space_type_name": "atrium_high", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 35 + "lighting_space_type_name": "ba_police_station_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 23, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "lounge_breakroom_general", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 78 + "lighting_space_type_name": "ba_school_university_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 27, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 471 }, { - "lighting_space_type_name": "lounge_breakroom_healthcare_facility", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 77 + "lighting_space_type_name": "ba_town_hall_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 29, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "dining_general", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 61 + "lighting_space_type_name": "ba_retail_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 26, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 }, { - "lighting_space_type_name": "dining_penitentiary", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 56 + "lighting_space_type_name": "ba_warehouse_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 31, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "dining_hotel", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 61 + "lighting_space_type_name": "audience_seating_area_for_gymnasium_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 39, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "dining_motel", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 61 + "lighting_space_type_name": "audience_seating_area_for_motion_picture_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 40, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "dining_bar_lounge_leisure", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 58 + "lighting_space_type_name": "audience_seating_area_for_penitentiary_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 41, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "dining_family", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 60 + "lighting_space_type_name": "audience_seating_area_for_performing_arts_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 42, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 426 }, { - "lighting_space_type_name": "dining_cafeteria_fast_food", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 59 + "lighting_space_type_name": "audience_seating_area_for_religious_buildings_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 43, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "dining_visually_impaired", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 57 + "lighting_space_type_name": "audience_seating_area_for_sports_arena_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 44, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "kitchen", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 64 + "lighting_space_type_name": "classroom_lecture_training_for_penitentiary_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 47, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 471 }, { - "lighting_space_type_name": "laboratory_classroom", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 66 + "lighting_space_type_name": "corridor_transition_for_hospital_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 50, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "laboratory_all_other", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 67 + "lighting_space_type_name": "dining_area_for_penitentiary_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 57, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "restroom_visually_impaired", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 84 + "lighting_space_type_name": "dining_bar_lounge_leisure_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 4, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "restroom_all_other", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 85 + "lighting_space_type_name": "dining_cafeteria_fast_food_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 5, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "performing_arts_dressing_room", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 120 + "lighting_space_type_name": "dining_area_for_family_dining_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 54, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "corridor_general", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 53 + "lighting_space_type_name": "lobby_for_hotel_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 65, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "corridor_hospital", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 52 + "lighting_space_type_name": "lobby_for_motion_picture_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 66, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "corridor_manufacturing_facility", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 53 + "lighting_space_type_name": "lobby_for_performing_arts_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 67, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 }, { - "lighting_space_type_name": "corridor_visually_impaired", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 51 + "lighting_space_type_name": "lounge_recreation_for_hospital_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 69, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 }, { - "lighting_space_type_name": "stairway", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 88 + "lighting_space_type_name": "office-enclosed_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 71, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "stairwell", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 89 + "lighting_space_type_name": "office_open_plan_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 72, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 414 }, { - "lighting_space_type_name": "storage_ all_other_small", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 90 + "lighting_space_type_name": "automotive_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 77, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "storage_ all_other_large", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 91 + "lighting_space_type_name": "convention_center_exhibit_space_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 79, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 431 }, { - "lighting_space_type_name": "storage_hospital_small", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 90 + "lighting_space_type_name": "library_reading_area_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 102, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "storage_hospital_large", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 91 + "lighting_space_type_name": "library_stacks_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 103, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "electrical_mechanical", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 62 + "lighting_space_type_name": "manufacturing_facility_detailed_manufacturing_area_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 105, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "workshop", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 93 + "lighting_space_type_name": "manufacturing_facility_equipment_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 106, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "gymnasium_playing_area", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 101 + "lighting_space_type_name": "manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 107, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "gymnasium_exercise_area", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 100 + "lighting_space_type_name": "manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 108, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "courtroom", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 54 + "lighting_space_type_name": "museum_restoration_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 110, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "confinement_cells", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 49 + "lighting_space_type_name": "post_office_sorting_area_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 112, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 }, { - "lighting_space_type_name": "emergency_vehicle_garage", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 63 + "lighting_space_type_name": "religious_buildings_fellowship_hall_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 113, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "firestation_sleeping_quarters", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 99 + "lighting_space_type_name": "religious_buildings_worship_pulpit_choir_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 114, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "post_office_sorting_area", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 121 + "lighting_space_type_name": "retail_mall_concourse_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 115, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 403 }, { - "lighting_space_type_name": "exhibit_convention_center", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 97 + "lighting_space_type_name": "transportation_facility_ticket_counter_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 126, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 }, { - "lighting_space_type_name": "library_stacks", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 112 + "lighting_space_type_name": "warehouse_storage_area_medium_to_bulky_palletized_items_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 128, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "library_reading", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 111 + "lighting_space_type_name": "warehouse_storage_area_smaller_hand-carried_items_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", + "level_3_lighting_code_definition_id": 127, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "recovery", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 110 + "lighting_space_type_name": "airport_concourse_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 128, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "nurses_station", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 106 + "lighting_space_type_name": "atrium_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 34, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "exam_treatment", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 102 + "lighting_space_type_name": "none_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 133, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 0 }, { - "lighting_space_type_name": "pharmacy", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 83 + "lighting_space_type_name": "audience_seating_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 36, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "patient_room", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 108 + "lighting_space_type_name": "baggage_carousel_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 127, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "operating_room", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 107 + "lighting_space_type_name": "banking_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 64, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "nursery", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 105 + "lighting_space_type_name": "classroom_lecture_training_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 39, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 471 }, { - "lighting_space_type_name": "medical_supply", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 104 + "lighting_space_type_name": "computer_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 39, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 710 }, { - "lighting_space_type_name": "physical_therapy", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 109 + "lighting_space_type_name": "conference_meeting_multipurpose_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 40, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "imaging", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 103 + "lighting_space_type_name": "confinement_cells_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 67, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 }, { - "lighting_space_type_name": "laundry_washing", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 68 + "lighting_space_type_name": "copy_print_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 40, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "automotive", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 96 + "lighting_space_type_name": "corridor_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 41, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "manufacturing_low_bay", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 117 + "lighting_space_type_name": "courtroom_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 68, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 }, { - "lighting_space_type_name": "manufacturing_high_bay", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 116 + "lighting_space_type_name": "datacenterhighite_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 46, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "detailed_manufacuring", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 113 + "lighting_space_type_name": "datacenterlowite_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 46, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "manufacturing_equipment_room", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 114 + "lighting_space_type_name": "dining_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 44, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 308 }, { - "lighting_space_type_name": "manufacturing_extra_high_bay", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 115 + "lighting_space_type_name": "dressing_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 113, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "guest_room", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 65 + "lighting_space_type_name": "electrical_mechanical_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 46, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "dormitory_living_quarters", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 98 + "lighting_space_type_name": "emergency_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 80, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 888 }, { - "lighting_space_type_name": "museum_exhibit_area", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 118 + "lighting_space_type_name": "emergency_vehicle_garage_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 74, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "museum_restoration", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 119 + "lighting_space_type_name": "exam_treatment_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 81, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "banking_activity", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 44 + "lighting_space_type_name": "exercise_area_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 76, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 }, { - "lighting_space_type_name": "worship_pulpit_choir_area", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 123 + "lighting_space_type_name": "exhibit_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 107, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 431 }, { - "lighting_space_type_name": "fellowship_hall_religious_facility", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 122 + "lighting_space_type_name": "guest_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 96, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "sales", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 86 + "lighting_space_type_name": "imaging_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 91, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "retail_mall_concourse", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 125 + "lighting_space_type_name": "interior_parking_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 109, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 54 }, { - "lighting_space_type_name": "retail_dressing_room", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 124 + "lighting_space_type_name": "judges_chambers_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 69, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "sports_arena_playing_area_class_I", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 126 + "lighting_space_type_name": "food_preparation_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 47, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 538 }, { - "lighting_space_type_name": "sports_arena_playing_area_class_II", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 127 + "lighting_space_type_name": "laboratory_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 49, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "sports_arena_playing_area_class_III", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 128 + "lighting_space_type_name": "laundry_washing_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 82, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "sports_arena_playing_area_class_IV", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 129 + "lighting_space_type_name": "library_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 14, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 }, { - "lighting_space_type_name": "warehouse_fine_storage", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 134 + "lighting_space_type_name": "living_quarters_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 73, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "warehouse_bulk_storage", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 133 + "lighting_space_type_name": "loading_dock_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 31, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "parking_area_interior", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 82 + "lighting_space_type_name": "lobby_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 53, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 }, { - "lighting_space_type_name": "airport_concourse", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 131 + "lighting_space_type_name": "locker_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 54, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "baggage_carousel", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 130 + "lighting_space_type_name": "lounge_breakroom_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 55, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "transportation_ticket_counter", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 132 + "lighting_space_type_name": "manufacturing_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 15, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "sales_display_type_1", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 135 + "lighting_space_type_name": "medical_supply_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 84, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "sales_display_type_2", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 136 + "lighting_space_type_name": "multifamily_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 18, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 }, { - "lighting_space_type_name": "sales_display_type_3", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 137 + "lighting_space_type_name": "nursery_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 85, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "sales_display_type_4", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 138 + "lighting_space_type_name": "nurses_station_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 86, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "breakroom", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 45 + "lighting_space_type_name": "office_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 20, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 414 }, { - "lighting_space_type_name": "copy_print", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 50 + "lighting_space_type_name": "office_enclosed_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 56, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "computer_room", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 55 + "lighting_space_type_name": "operating_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 87, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 1184 }, { - "lighting_space_type_name": "loading_dock", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 69 + "lighting_space_type_name": "patient_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 88, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 }, { - "lighting_space_type_name": "locker_room", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 76 + "lighting_space_type_name": "pharmacy_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 89, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 888 }, { - "lighting_space_type_name": "seating_area_general", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 87 + "lighting_space_type_name": "physical_therapy_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 90, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 }, { - "lighting_space_type_name": "vehicular_maintenance", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 92 + "lighting_space_type_name": "playing_area_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 78, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 }, { - "lighting_space_type_name": "chapel_visually_impaired", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 94 + "lighting_space_type_name": "post_office_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 25, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 }, { - "lighting_space_type_name": "recreation_common_living_visually_impaired", - "level_3_lighting_definition_table": "level_3_lighting_90_1_2019", - "level_3_lighting_definition_id": 95 + "lighting_space_type_name": "recovery_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 92, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "recreation_common_living_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 55, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 323 + }, + { + "lighting_space_type_name": "restroom_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 58, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "retail_sales_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 119, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 + }, + { + "lighting_space_type_name": "sleeping_quarters_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 75, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 59 + }, + { + "lighting_space_type_name": "sports_arena_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 29, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 1184 + }, + { + "lighting_space_type_name": "stairwell_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 60, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "storage_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 61, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "transportation_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 31, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "vehicular_maintenance_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 63, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "workshop_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 33, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "worship_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 26, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "ba_automotive_facility_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 1, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "ba_convention_center_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 2, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "ba_courthouse_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 3, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 + }, + { + "lighting_space_type_name": "ba_dining_bar_lounge_leisure_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 4, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "ba_dining_cafeteria_fast_food_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 5, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "ba_dining_family_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 6, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "ba_dormitory_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 7, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "ba_exercise_center_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 8, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "ba_fire_station_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 9, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "ba_gymnasium_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 10, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "ba_health-care_clinic_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 11, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "ba_hospital_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 12, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "ba_hotel_motel_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 13, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "ba_motion_picture_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 17, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "ba_museum_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 19, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "ba_parking_garage_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 21, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 54 + }, + { + "lighting_space_type_name": "ba_penitentiary_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 22, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 + }, + { + "lighting_space_type_name": "ba_performing_arts_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 23, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 426 + }, + { + "lighting_space_type_name": "ba_police_station_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 24, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "ba_school_university_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 28, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 471 + }, + { + "lighting_space_type_name": "ba_town_hall_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 30, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "ba_retail_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 27, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 + }, + { + "lighting_space_type_name": "ba_warehouse_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 32, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "audience_seating_area_for_gymnasium_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 77, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "audience_seating_area_for_motion_picture_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 37, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "audience_seating_area_for_penitentiary_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 70, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "audience_seating_area_for_performing_arts_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 38, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 426 + }, + { + "lighting_space_type_name": "audience_seating_area_for_religious_buildings_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 110, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "audience_seating_area_for_sports_arena_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 120, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "classroom_lecture_training_for_penitentiary_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 71, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 471 + }, + { + "lighting_space_type_name": "corridor_transition_for_hospital_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 79, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "dining_area_for_penitentiary_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 72, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "dining_bar_lounge_leisure_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 4, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "dining_cafeteria_fast_food_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 5, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "dining_area_for_family_dining_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 43, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "lobby_for_hotel_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 97, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "lobby_for_motion_picture_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 51, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "lobby_for_performing_arts_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 52, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 + }, + { + "lighting_space_type_name": "lounge_recreation_for_hospital_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 83, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 + }, + { + "lighting_space_type_name": "office-enclosed_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 56, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "office_open_plan_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 57, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 414 + }, + { + "lighting_space_type_name": "automotive_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 63, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "convention_center_exhibit_space_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 66, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 431 + }, + { + "lighting_space_type_name": "library_reading_area_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 99, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "library_stacks_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 100, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "manufacturing_facility_detailed_manufacturing_area_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 102, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "manufacturing_facility_equipment_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 103, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 105, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 106, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "museum_restoration_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 108, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "post_office_sorting_area_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 126, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 + }, + { + "lighting_space_type_name": "religious_buildings_fellowship_hall_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 111, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "religious_buildings_worship_pulpit_choir_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 112, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "retail_mall_concourse_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 114, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 403 + }, + { + "lighting_space_type_name": "transportation_facility_ticket_counter_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 130, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 + }, + { + "lighting_space_type_name": "warehouse_storage_area_medium_to_bulky_palletized_items_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 132, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "warehouse_storage_area_smaller_hand-carried_items_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", + "level_3_lighting_code_definition_id": 131, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "airport_concourse_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 140, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "atrium_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 33, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "none_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 143, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 0 + }, + { + "lighting_space_type_name": "audience_seating_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 36, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "baggage_carousel_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 139, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "banking_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 45, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "classroom_lecture_training_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 47, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 471 + }, + { + "lighting_space_type_name": "computer_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 49, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 710 + }, + { + "lighting_space_type_name": "conference_meeting_multipurpose_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 50, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "confinement_cells_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 51, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 + }, + { + "lighting_space_type_name": "copy_print_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 52, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "corridor_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 53, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "courtroom_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 57, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 + }, + { + "lighting_space_type_name": "datacenterhighite_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 64, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "datacenterlowite_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 64, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "dining_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 58, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 308 + }, + { + "lighting_space_type_name": "dressing_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 128, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "electrical_mechanical_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 64, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "emergency_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 112, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 888 + }, + { + "lighting_space_type_name": "emergency_vehicle_garage_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 65, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "exam_treatment_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 112, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "exercise_area_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 105, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 + }, + { + "lighting_space_type_name": "exhibit_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 122, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 431 + }, + { + "lighting_space_type_name": "guest_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 67, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "imaging_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 113, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "interior_parking_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 84, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 54 + }, + { + "lighting_space_type_name": "judges_chambers_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 57, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "food_preparation_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 66, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 538 + }, + { + "lighting_space_type_name": "laboratory_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 68, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "laundry_washing_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 70, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "library_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 14, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "living_quarters_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 99, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "loading_dock_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 71, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "lobby_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 72, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 + }, + { + "lighting_space_type_name": "locker_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 78, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "lounge_breakroom_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 46, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "manufacturing_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 15, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "medical_supply_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 106, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "multifamily_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 17, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "nursery_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 108, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "nurses_station_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 107, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "office_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 19, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 414 + }, + { + "lighting_space_type_name": "office_enclosed_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 81, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "operating_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 114, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 1184 + }, + { + "lighting_space_type_name": "patient_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 109, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "pharmacy_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 106, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 888 + }, + { + "lighting_space_type_name": "physical_therapy_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 110, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 + }, + { + "lighting_space_type_name": "playing_area_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 104, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "post_office_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 24, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "recovery_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 111, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "recreation_common_living_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 79, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 323 + }, + { + "lighting_space_type_name": "restroom_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 86, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "retail_sales_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 88, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 + }, + { + "lighting_space_type_name": "sleeping_quarters_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 103, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 59 + }, + { + "lighting_space_type_name": "sports_arena_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 28, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 1184 + }, + { + "lighting_space_type_name": "stairwell_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 91, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "storage_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 94, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "transportation_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 30, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "vehicular_maintenance_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 95, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "workshop_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 32, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "worship_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 25, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "ba_automotive_facility_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 1, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "ba_convention_center_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 2, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "ba_courthouse_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 3, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 + }, + { + "lighting_space_type_name": "ba_dining_bar_lounge_leisure_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 4, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "ba_dining_cafeteria_fast_food_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 5, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "ba_dining_family_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 6, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "ba_dormitory_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 7, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "ba_exercise_center_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 8, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "ba_fire_station_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 9, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "ba_gymnasium_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 10, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "ba_health-care_clinic_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 11, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "ba_hospital_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 12, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "ba_hotel_motel_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 13, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "ba_motion_picture_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 16, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "ba_museum_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 18, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "ba_parking_garage_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 20, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 54 + }, + { + "lighting_space_type_name": "ba_penitentiary_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 21, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 + }, + { + "lighting_space_type_name": "ba_performing_arts_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 22, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 426 + }, + { + "lighting_space_type_name": "ba_police_station_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 23, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "ba_school_university_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 27, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 471 + }, + { + "lighting_space_type_name": "ba_town_hall_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 29, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "ba_retail_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 26, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 + }, + { + "lighting_space_type_name": "ba_warehouse_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 31, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "audience_seating_area_for_gymnasium_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 38, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "audience_seating_area_for_motion_picture_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 39, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "audience_seating_area_for_penitentiary_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 40, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "audience_seating_area_for_performing_arts_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 41, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 426 + }, + { + "lighting_space_type_name": "audience_seating_area_for_religious_buildings_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 42, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "audience_seating_area_for_sports_arena_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 43, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "classroom_lecture_training_for_penitentiary_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 48, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 471 + }, + { + "lighting_space_type_name": "corridor_transition_for_hospital_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 55, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "dining_area_for_penitentiary_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 60, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "dining_bar_lounge_leisure_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 4, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "dining_cafeteria_fast_food_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 5, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "dining_area_for_family_dining_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 63, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "lobby_for_hotel_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 75, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "lobby_for_motion_picture_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 76, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "lobby_for_performing_arts_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 77, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 + }, + { + "lighting_space_type_name": "lounge_recreation_for_hospital_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 80, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 + }, + { + "lighting_space_type_name": "office-enclosed_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 81, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "office_open_plan_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 83, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 414 + }, + { + "lighting_space_type_name": "automotive_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 97, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "convention_center_exhibit_space_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 98, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 431 + }, + { + "lighting_space_type_name": "library_reading_area_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 115, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "library_stacks_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 116, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "manufacturing_facility_detailed_manufacturing_area_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 117, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "manufacturing_facility_equipment_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 120, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 118, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 119, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "museum_restoration_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 123, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "post_office_sorting_area_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 125, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 + }, + { + "lighting_space_type_name": "religious_buildings_fellowship_hall_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 127, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "religious_buildings_worship_pulpit_choir_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 126, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "retail_mall_concourse_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 129, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 403 + }, + { + "lighting_space_type_name": "transportation_facility_ticket_counter_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 138, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 + }, + { + "lighting_space_type_name": "warehouse_storage_area_medium_to_bulky_palletized_items_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 141, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "warehouse_storage_area_smaller_hand-carried_items_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", + "level_3_lighting_code_definition_id": 142, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "airport_concourse_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 137, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "atrium_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 33, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "none_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 142, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 0 + }, + { + "lighting_space_type_name": "audience_seating_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 36, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "baggage_carousel_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 138, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "banking_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 45, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "classroom_lecture_training_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 47, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 471 + }, + { + "lighting_space_type_name": "computer_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 49, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 710 + }, + { + "lighting_space_type_name": "conference_meeting_multipurpose_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 50, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "confinement_cells_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 51, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 + }, + { + "lighting_space_type_name": "copy_print_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 52, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "corridor_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 53, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "courtroom_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 57, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 + }, + { + "lighting_space_type_name": "datacenterhighite_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 64, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "datacenterlowite_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 64, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "dining_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 58, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 308 + }, + { + "lighting_space_type_name": "dressing_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 127, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "electrical_mechanical_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 64, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "emergency_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 105, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 888 + }, + { + "lighting_space_type_name": "emergency_vehicle_garage_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 65, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "exam_treatment_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 105, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "exercise_area_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 103, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 + }, + { + "lighting_space_type_name": "exhibit_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 121, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 431 + }, + { + "lighting_space_type_name": "guest_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 67, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "imaging_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 106, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "interior_parking_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 84, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 54 + }, + { + "lighting_space_type_name": "judges_chambers_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 57, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "food_preparation_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 66, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 538 + }, + { + "lighting_space_type_name": "laboratory_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 68, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "laundry_washing_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 70, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "library_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 14, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "living_quarters_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 99, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "loading_dock_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 71, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "lobby_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 72, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 + }, + { + "lighting_space_type_name": "locker_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 78, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "lounge_breakroom_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 46, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "manufacturing_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 15, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "medical_supply_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 107, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "multifamily_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 17, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "nursery_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 109, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "nurses_station_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 108, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "office_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 19, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 414 + }, + { + "lighting_space_type_name": "office_enclosed_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 81, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "operating_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 110, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 1184 + }, + { + "lighting_space_type_name": "patient_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 111, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "pharmacy_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 107, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 888 + }, + { + "lighting_space_type_name": "physical_therapy_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 112, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 + }, + { + "lighting_space_type_name": "playing_area_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 104, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "post_office_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 24, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "recovery_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 113, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "recreation_common_living_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 79, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 323 + }, + { + "lighting_space_type_name": "restroom_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 86, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "retail_sales_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 88, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 + }, + { + "lighting_space_type_name": "sleeping_quarters_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 102, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 59 + }, + { + "lighting_space_type_name": "sports_arena_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 28, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 1184 + }, + { + "lighting_space_type_name": "stairwell_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 91, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "storage_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 94, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "transportation_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 30, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "vehicular_maintenance_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 95, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "workshop_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 32, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "worship_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 25, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "ba_automotive_facility_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 1, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "ba_convention_center_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 2, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "ba_courthouse_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 3, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 + }, + { + "lighting_space_type_name": "ba_dining_bar_lounge_leisure_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 4, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "ba_dining_cafeteria_fast_food_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 5, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "ba_dining_family_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 6, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "ba_dormitory_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 7, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "ba_exercise_center_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 8, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "ba_fire_station_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 9, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "ba_gymnasium_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 10, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "ba_health-care_clinic_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 11, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "ba_hospital_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 12, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "ba_hotel_motel_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 13, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "ba_motion_picture_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 16, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "ba_museum_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 18, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "ba_parking_garage_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 20, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 54 + }, + { + "lighting_space_type_name": "ba_penitentiary_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 21, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 + }, + { + "lighting_space_type_name": "ba_performing_arts_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 22, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 426 + }, + { + "lighting_space_type_name": "ba_police_station_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 23, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "ba_school_university_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 27, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 471 + }, + { + "lighting_space_type_name": "ba_town_hall_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 29, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "ba_retail_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 26, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 + }, + { + "lighting_space_type_name": "ba_warehouse_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 31, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "audience_seating_area_for_gymnasium_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 39, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "audience_seating_area_for_motion_picture_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 40, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "audience_seating_area_for_penitentiary_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 41, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "audience_seating_area_for_performing_arts_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 42, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 426 + }, + { + "lighting_space_type_name": "audience_seating_area_for_religious_buildings_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 43, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "audience_seating_area_for_sports_arena_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 44, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "classroom_lecture_training_for_penitentiary_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 48, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 471 + }, + { + "lighting_space_type_name": "corridor_transition_for_hospital_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 55, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "dining_area_for_penitentiary_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 61, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "dining_bar_lounge_leisure_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 4, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "dining_cafeteria_fast_food_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 5, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "dining_area_for_family_dining_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 62, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "lobby_for_hotel_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 75, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "lobby_for_motion_picture_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 76, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "lobby_for_performing_arts_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 77, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 + }, + { + "lighting_space_type_name": "lounge_recreation_for_hospital_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 80, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 + }, + { + "lighting_space_type_name": "office-enclosed_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 81, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "office_open_plan_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 83, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 414 + }, + { + "lighting_space_type_name": "automotive_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 97, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "convention_center_exhibit_space_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 98, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 431 + }, + { + "lighting_space_type_name": "library_reading_area_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 114, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "library_stacks_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 115, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "manufacturing_facility_detailed_manufacturing_area_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 116, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "manufacturing_facility_equipment_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 117, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 119, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 120, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "museum_restoration_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 122, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "post_office_sorting_area_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 124, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 + }, + { + "lighting_space_type_name": "religious_buildings_fellowship_hall_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 125, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "religious_buildings_worship_pulpit_choir_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 126, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "retail_mall_concourse_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 128, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 403 + }, + { + "lighting_space_type_name": "transportation_facility_ticket_counter_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 139, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 + }, + { + "lighting_space_type_name": "warehouse_storage_area_medium_to_bulky_palletized_items_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 140, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "warehouse_storage_area_smaller_hand-carried_items_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", + "level_3_lighting_code_definition_id": 141, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "airport_concourse_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 134, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "atrium_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 33, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "none_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 139, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 0 + }, + { + "lighting_space_type_name": "audience_seating_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 36, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "baggage_carousel_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 135, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "banking_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 44, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "classroom_lecture_training_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 46, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 471 + }, + { + "lighting_space_type_name": "computer_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 48, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 710 + }, + { + "lighting_space_type_name": "conference_meeting_multipurpose_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 49, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "confinement_cells_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 50, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 + }, + { + "lighting_space_type_name": "copy_print_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 51, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "corridor_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 52, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "courtroom_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 55, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 + }, + { + "lighting_space_type_name": "datacenterhighite_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 62, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "datacenterlowite_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 62, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "dining_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 56, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 308 + }, + { + "lighting_space_type_name": "dressing_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 124, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "electrical_mechanical_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 62, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "emergency_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 102, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 888 + }, + { + "lighting_space_type_name": "emergency_vehicle_garage_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 63, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "exam_treatment_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 102, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "exercise_area_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 100, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 + }, + { + "lighting_space_type_name": "exhibit_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 118, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 431 + }, + { + "lighting_space_type_name": "guest_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 65, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "imaging_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 103, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "interior_parking_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 82, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 54 + }, + { + "lighting_space_type_name": "judges_chambers_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 55, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "food_preparation_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 64, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 538 + }, + { + "lighting_space_type_name": "laboratory_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 66, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "laundry_washing_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 68, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "library_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 14, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "living_quarters_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 96, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "loading_dock_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 69, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "lobby_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 70, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 + }, + { + "lighting_space_type_name": "locker_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 76, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "lounge_breakroom_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 45, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "manufacturing_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 15, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "medical_supply_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 104, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "multifamily_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 17, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "nursery_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 105, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "nurses_station_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 106, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "office_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 19, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 414 + }, + { + "lighting_space_type_name": "office_enclosed_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 79, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "operating_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 107, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 1184 + }, + { + "lighting_space_type_name": "patient_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 108, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "pharmacy_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 104, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 888 + }, + { + "lighting_space_type_name": "physical_therapy_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 109, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 + }, + { + "lighting_space_type_name": "playing_area_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 101, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "post_office_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 24, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "recovery_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 110, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "recreation_common_living_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 77, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 323 + }, + { + "lighting_space_type_name": "restroom_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 84, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "retail_sales_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 86, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 + }, + { + "lighting_space_type_name": "sleeping_quarters_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 99, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 59 + }, + { + "lighting_space_type_name": "sports_arena_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 28, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 1184 + }, + { + "lighting_space_type_name": "stairwell_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 89, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "storage_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 91, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "transportation_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 30, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "vehicular_maintenance_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 92, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "workshop_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 32, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "worship_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 25, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "ba_automotive_facility_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 1, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "ba_convention_center_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 2, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "ba_courthouse_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 3, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 + }, + { + "lighting_space_type_name": "ba_dining_bar_lounge_leisure_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 4, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "ba_dining_cafeteria_fast_food_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 5, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "ba_dining_family_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 6, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "ba_dormitory_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 7, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "ba_exercise_center_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 8, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "ba_fire_station_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 9, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "ba_gymnasium_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 10, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "ba_health-care_clinic_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 11, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "ba_hospital_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 12, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "ba_hotel_motel_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 13, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "ba_motion_picture_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 16, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "ba_museum_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 18, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "ba_parking_garage_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 20, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 54 + }, + { + "lighting_space_type_name": "ba_penitentiary_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 21, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 + }, + { + "lighting_space_type_name": "ba_performing_arts_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 22, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 426 + }, + { + "lighting_space_type_name": "ba_police_station_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 23, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "ba_school_university_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 27, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 471 + }, + { + "lighting_space_type_name": "ba_town_hall_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 29, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "ba_retail_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 26, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 + }, + { + "lighting_space_type_name": "ba_warehouse_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 31, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "audience_seating_area_for_gymnasium_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 38, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "audience_seating_area_for_motion_picture_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 39, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "audience_seating_area_for_penitentiary_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 40, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "audience_seating_area_for_performing_arts_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 41, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 426 + }, + { + "lighting_space_type_name": "audience_seating_area_for_religious_buildings_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 42, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "audience_seating_area_for_sports_arena_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 43, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "classroom_lecture_training_for_penitentiary_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 47, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 471 + }, + { + "lighting_space_type_name": "corridor_transition_for_hospital_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 54, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "dining_area_for_penitentiary_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 61, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "dining_bar_lounge_leisure_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 57, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "dining_cafeteria_fast_food_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 58, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "dining_area_for_family_dining_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 60, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "lobby_for_hotel_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 73, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 178 + }, + { + "lighting_space_type_name": "lobby_for_motion_picture_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 74, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 118 + }, + { + "lighting_space_type_name": "lobby_for_performing_arts_theater_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 75, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 + }, + { + "lighting_space_type_name": "lounge_recreation_for_hospital_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 78, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 + }, + { + "lighting_space_type_name": "office-enclosed_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 80, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "office_open_plan_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 81, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 414 + }, + { + "lighting_space_type_name": "automotive_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 94, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "convention_center_exhibit_space_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 95, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 431 + }, + { + "lighting_space_type_name": "library_reading_area_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 111, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "library_stacks_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 112, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "manufacturing_facility_detailed_manufacturing_area_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 113, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "manufacturing_facility_equipment_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 114, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 + }, + { + "lighting_space_type_name": "manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 116, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 117, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "museum_restoration_room_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 119, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 592 + }, + { + "lighting_space_type_name": "post_office_sorting_area_general_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 121, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 474 + }, + { + "lighting_space_type_name": "religious_buildings_fellowship_hall_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 122, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "religious_buildings_worship_pulpit_choir_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 123, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "retail_mall_concourse_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 125, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 403 + }, + { + "lighting_space_type_name": "transportation_facility_ticket_counter_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 136, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 296 + }, + { + "lighting_space_type_name": "warehouse_storage_area_medium_to_bulky_palletized_items_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 137, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 355 + }, + { + "lighting_space_type_name": "warehouse_storage_area_smaller_hand-carried_items_lighting", + "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", + "level_3_lighting_code_definition_id": 138, + "lighting_technology_name": "default", + "lighting_space_type_target_illuminance_setpoint": 237 } ] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/level_2_natural_gas_equipment.csv b/data/openstudio_standards_data/database_files/level_2_natural_gas_equipment.csv new file mode 100644 index 0000000000..b842378127 --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_2_natural_gas_equipment.csv @@ -0,0 +1,7 @@ +natural_gas_equipment_space_type_name,natural_gas_equipment_minimum_epd,natural_gas_equipment_average_epd,natural_gas_equipment_median_epd,natural_gas_equipment_maximum_epd,natural_gas_equipment_epd_unit +Kitchen,51.16,361.7807576,302.6,767,Btu/hr.ft2 +Laundry,42.6,138.4291667,129.9,170,Btu/hr.ft2 +OR,17.4,23.223,23.87,23.87,Btu/hr.ft2 +Deli,8.52,8.5225,8.52,8.53,Btu/hr.ft2 +Bakery,8.53,8.5375,8.54,8.54,Btu/hr.ft2 +Deli/Bakery,6.25,6.25,6.25,6.25,Btu/hr.ft2 diff --git a/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.csv b/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.csv index 85d239f91e..2d6b7b80f1 100644 --- a/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.csv +++ b/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.csv @@ -1,174 +1,526 @@ ventilation_space_type_name,level_3_ventilation_definition_table,level_3_ventilation_definition_id -correctional_facilities_cell,level_3_ventilation_62_1_2019,13 -correctional_facilities_dayroom,level_3_ventilation_62_1_2019,14 -correctional_facilities_guard_stations,level_3_ventilation_62_1_2019,15 -correctional_facilities_booking_waiting,level_3_ventilation_62_1_2019,12 -educational_facilities_daycare,level_3_ventilation_62_1_2019,21 -educational_facilities_classroom_young,level_3_ventilation_62_1_2019,17 -educational_facilities_classroom_old,level_3_ventilation_62_1_2019,18 -educational_facilities_lecture_classroom,level_3_ventilation_62_1_2019,22 -educational_facilities_lecture_hall,level_3_ventilation_62_1_2019,23 -educational_facilities_art_classroom,level_3_ventilation_62_1_2019,16 -educational_facilities_science_laboratories,level_3_ventilation_62_1_2019,28 -educational_facilities_wood_metal_shop,level_3_ventilation_62_1_2019,30 -educational_facilities_computer_lab,level_3_ventilation_62_1_2019,19 -educational_facilities_media_center,level_3_ventilation_62_1_2019,25 -educational_facilities_music_theater_dance,level_3_ventilation_62_1_2019,27 -educational_facilities_multiuse_assembly,level_3_ventilation_62_1_2019,26 -educational_facilities_daycare_sickroom,level_3_ventilation_62_1_2019,20 -educational_facilities_libraries,level_3_ventilation_62_1_2019,24 -educational_facilities_university_college_laboratories,level_3_ventilation_62_1_2019,29 -food_beverage_service_restaurant_dining_rooms,level_3_ventilation_62_1_2019,34 -food_beverage_service_cafeteria_fast_food_dining,level_3_ventilation_62_1_2019,32 -food_beverage_service_bars_cocktail_lounges,level_3_ventilation_62_1_2019,31 -food_beverage_service_kitchen,level_3_ventilation_62_1_2019,33 -general_conference_meeting,level_3_ventilation_62_1_2019,37 -general_conference_corridors,level_3_ventilation_62_1_2019,38 -general_conference_storage_rooms,level_3_ventilation_62_1_2019,39 -general_break_rooms,level_3_ventilation_62_1_2019,35 -general_coffee_stations,level_3_ventilation_62_1_2019,36 -hotels_motels_resorts_dormitories_bedroom_living_room,level_3_ventilation_62_1_2019,41 -hotels_motels_resorts_dormitories_barracks_sleeping_areas,level_3_ventilation_62_1_2019,40 -hotels_motels_resorts_dormitories_lobbies_prefunction,level_3_ventilation_62_1_2019,44 -hotels_motels_resorts_dormitories_multi_purpose_assembly,level_3_ventilation_62_1_2019,45 -hotels_motels_resorts_dormitories_laundry_rooms,level_3_ventilation_62_1_2019,42 -hotels_motels_resorts_dormitories_laundry_rooms_w_dwelling_units,level_3_ventilation_62_1_2019,43 -office_buildings_office_space,level_3_ventilation_62_1_2019,62 -office_buildings_reception_areas,level_3_ventilation_62_1_2019,63 -office_buildings_telephone_data_entry,level_3_ventilation_62_1_2019,64 -office_buildings_main_entry_lobbies,level_3_ventilation_62_1_2019,60 -office_buildings_breakrooms,level_3_ventilation_62_1_2019,59 -office_buildings_occupiable_storage_rooms,level_3_ventilation_62_1_2019,61 -miscellaneous_spaces_bank_ vaults_safe_deposit,level_3_ventilation_62_1_2019,47 -miscellaneous_spaces_computer,level_3_ventilation_62_1_2019,48 -miscellaneous_spaces_pharmacy,level_3_ventilation_62_1_2019,52 -miscellaneous_spaces_photo_studios,level_3_ventilation_62_1_2019,53 -miscellaneous_spaces_shipping_receiving,level_3_ventilation_62_1_2019,54 -miscellaneous_spaces_transportation_waiting,level_3_ventilation_62_1_2019,57 -miscellaneous_spaces_warehouses,level_3_ventilation_62_1_2019,58 -miscellaneous_spaces_banks_bank_lobbies,level_3_ventilation_62_1_2019,46 -miscellaneous_spaces_freezer_refrigerated_spaces,level_3_ventilation_62_1_2019,49 -miscellaneous_spaces_manufacturing_wo_hazardous_materials,level_3_ventilation_62_1_2019,50 -miscellaneous_spaces_manufacturing_w_hazardous_materials,level_3_ventilation_62_1_2019,51 -miscellaneous_spaces_sorting_packing_light_assembly,level_3_ventilation_62_1_2019,55 -miscellaneous_spaces_telephone_closets,level_3_ventilation_62_1_2019,56 -public_assembly_spaces_auditorium_seating_area,level_3_ventilation_62_1_2019,83 -public_assembly_spaces_religious_workshop,level_3_ventilation_62_1_2019,90 -public_assembly_spaces_courtrooms,level_3_ventilation_62_1_2019,84 -public_assembly_spaces_legislative_chambers,level_3_ventilation_62_1_2019,85 -public_assembly_spaces_libraries,level_3_ventilation_62_1_2019,86 -public_assembly_spaces_lobbies,level_3_ventilation_62_1_2019,87 -public_assembly_spaces_children_museums,level_3_ventilation_62_1_2019,88 -public_assembly_spaces_museums_galleries,level_3_ventilation_62_1_2019,89 -retail_sales,level_3_ventilation_62_1_2019,91 -retail_mall_common_areas,level_3_ventilation_62_1_2019,95 -retail_barbershop,level_3_ventilation_62_1_2019,92 -retail_beauty_nail_salons,level_3_ventilation_62_1_2019,93 -retail_pet_shops,level_3_ventilation_62_1_2019,96 -retail_supermarket,level_3_ventilation_62_1_2019,97 -retail_coin_operated_laundries,level_3_ventilation_62_1_2019,94 -sports_entertainment_sports_arena,level_3_ventilation_62_1_2019,102 -sports_entertainment_gym_stadium,level_3_ventilation_62_1_2019,102 -sports_entertainment_spectator_areas,level_3_ventilation_62_1_2019,105 -sports_entertainment_swimming,level_3_ventilation_62_1_2019,107 -sports_entertainment_disco_dance_floors,level_3_ventilation_62_1_2019,99 -sports_entertainment_health_club_aerobics_room,level_3_ventilation_62_1_2019,103 -sports_entertainment_health_club_weight_rooms,level_3_ventilation_62_1_2019,104 -sports_entertainment_bowling_alley,level_3_ventilation_62_1_2019,98 -sports_entertainment_gambling_casinos,level_3_ventilation_62_1_2019,100 -sports_entertainment_game_arcades,level_3_ventilation_62_1_2019,101 -sports_entertainment_stages_studios,level_3_ventilation_62_1_2019,106 -animal_facilities_animal_exam_room,level_3_ventilation_62_1_2019,1 -animal_facilities_animal_imaging,level_3_ventilation_62_1_2019,2 -animal_facilities_animal_operating_rooms,level_3_ventilation_62_1_2019,3 -animal_facilities_animal_postoperative_recovery_room,level_3_ventilation_62_1_2019,4 -animal_facilities_animal_preparation_rooms,level_3_ventilation_62_1_2019,5 -animal_facilities_animal_procedure_room,level_3_ventilation_62_1_2019,6 -animal_facilities_animal_surgery_scrub,level_3_ventilation_62_1_2019,7 -animal_facilities_large_animal_holding_room,level_3_ventilation_62_1_2019,8 -animal_facilities_necropsy,level_3_ventilation_62_1_2019,9 -animal_facilities_small_animal_cage_room_static,level_3_ventilation_62_1_2019,10 -animal_facilities_small_animal_cage_room_ventilated,level_3_ventilation_62_1_2019,11 -outpatient_health_care_facilities_birthing_room,level_3_ventilation_62_1_2019,65 -outpatient_health_care_facilities_class_1_imaging_rooms,level_3_ventilation_62_1_2019,66 -outpatient_health_care_facilities_dental_operatory,level_3_ventilation_62_1_2019,67 -outpatient_health_care_facilities_general_examination_room,level_3_ventilation_62_1_2019,68 -outpatient_health_care_facilities_other_dental_treatment_areas,level_3_ventilation_62_1_2019,69 -outpatient_health_care_facilities_physical_therapy_exercise_area,level_3_ventilation_62_1_2019,70 -outpatient_health_care_facilities_physical_therapy_individual_room,level_3_ventilation_62_1_2019,71 -outpatient_health_care_facilities_physical_therapeutic_pool_area,level_3_ventilation_62_1_2019,72 -outpatient_health_care_facilities_prosthetics_orthotics_room,level_3_ventilation_62_1_2019,73 -outpatient_health_care_facilities_psychiatric_consultation_room,level_3_ventilation_62_1_2019,74 -outpatient_health_care_facilities_psychiatric_examination_room,level_3_ventilation_62_1_2019,75 -outpatient_health_care_facilities_psychiatric_group_room,level_3_ventilation_62_1_2019,76 -outpatient_health_care_facilities_psychiatric_seclusion_room,level_3_ventilation_62_1_2019,77 -outpatient_health_care_facilities_speech_therapy_room,level_3_ventilation_62_1_2019,78 -outpatient_health_care_facilities_urgent_care_examination_room,level_3_ventilation_62_1_2019,79 -outpatient_health_care_facilities_urgent_care_observation_room,level_3_ventilation_62_1_2019,80 -outpatient_health_care_facilities_urgent_care_treatment_room,level_3_ventilation_62_1_2019,81 -outpatient_health_care_facilities_urgent_care_triage_room,level_3_ventilation_62_1_2019,82 -transient_residential_common_corridors,level_3_ventilation_62_1_2019,108 -transient_residential_dwelling_unit,level_3_ventilation_62_1_2019,109 -correctional_facilities_cell,level_3_ventilation_62_1_2004,1 -correctional_facilities_dayroom,level_3_ventilation_62_1_2004,2 -correctional_facilities_guard_stations,level_3_ventilation_62_1_2004,3 -correctional_facilities_booking_waiting,level_3_ventilation_62_1_2004,4 -educational_facilities_daycare,level_3_ventilation_62_1_2004,5 -educational_facilities_classroom_young,level_3_ventilation_62_1_2004,6 -educational_facilities_classroom_old,level_3_ventilation_62_1_2004,7 -educational_facilities_lecture_classroom,level_3_ventilation_62_1_2004,8 -educational_facilities_lecture_hall,level_3_ventilation_62_1_2004,9 -educational_facilities_art_classroom,level_3_ventilation_62_1_2004,10 -educational_facilities_science_laboratories,level_3_ventilation_62_1_2004,11 -educational_facilities_wood_metal_shop,level_3_ventilation_62_1_2004,12 -educational_facilities_computer_lab,level_3_ventilation_62_1_2004,13 -educational_facilities_media_center,level_3_ventilation_62_1_2004,14 -educational_facilities_music_theater_dance,level_3_ventilation_62_1_2004,15 -educational_facilities_multiuse_assembly,level_3_ventilation_62_1_2004,16 -food_beverage_service_restaurant_dining_rooms,level_3_ventilation_62_1_2004,17 -food_beverage_service_cafeteria_fast_food_dining,level_3_ventilation_62_1_2004,18 -food_beverage_service_bars_cocktail_lounges,level_3_ventilation_62_1_2004,19 -general_conference_meeting,level_3_ventilation_62_1_2004,20 -general_conference_corridors,level_3_ventilation_62_1_2004,21 -general_conference_storage_rooms,level_3_ventilation_62_1_2004,22 -hotels_motels_resorts_dormitories_bedroom_living_room,level_3_ventilation_62_1_2004,23 -hotels_motels_resorts_dormitories_barracks_sleeping_areas,level_3_ventilation_62_1_2004,24 -hotels_motels_resorts_dormitories_lobbies_prefunction,level_3_ventilation_62_1_2004,25 -hotels_motels_resorts_dormitories_multi_purpose_assembly,level_3_ventilation_62_1_2004,26 -office_buildings_office_space,level_3_ventilation_62_1_2004,27 -office_buildings_reception_areas,level_3_ventilation_62_1_2004,28 -office_buildings_telephone_data_entry,level_3_ventilation_62_1_2004,29 -office_buildings_main_entry_lobbies,level_3_ventilation_62_1_2004,30 -miscellaneous_spaces_bank_ vaults_safe_deposit,level_3_ventilation_62_1_2004,31 -miscellaneous_spaces_computer,level_3_ventilation_62_1_2004,32 -miscellaneous_spaces_pharmacy,level_3_ventilation_62_1_2004,33 -miscellaneous_spaces_photo_studios,level_3_ventilation_62_1_2004,34 -miscellaneous_spaces_shipping_receiving,level_3_ventilation_62_1_2004,35 -miscellaneous_spaces_transportation_waiting,level_3_ventilation_62_1_2004,36 -miscellaneous_spaces_warehouses,level_3_ventilation_62_1_2004,37 -public_assembly_spaces_auditorium_seating_area,level_3_ventilation_62_1_2004,38 -public_assembly_spaces_religious_workshop,level_3_ventilation_62_1_2004,39 -public_assembly_spaces_courtrooms,level_3_ventilation_62_1_2004,40 -public_assembly_spaces_legislative_chambers,level_3_ventilation_62_1_2004,41 -public_assembly_spaces_libraries,level_3_ventilation_62_1_2004,42 -public_assembly_spaces_lobbies,level_3_ventilation_62_1_2004,43 -public_assembly_spaces_children_museums,level_3_ventilation_62_1_2004,44 -public_assembly_spaces_museums_galleries,level_3_ventilation_62_1_2004,45 -retail_sales,level_3_ventilation_62_1_2004,46 -retail_mall_common_areas,level_3_ventilation_62_1_2004,47 -retail_barbershop,level_3_ventilation_62_1_2004,48 -retail_beauty_nail_salons,level_3_ventilation_62_1_2004,49 -retail_pet_shops,level_3_ventilation_62_1_2004,50 -retail_supermarket,level_3_ventilation_62_1_2004,51 -retail_coin_operated_laundries,level_3_ventilation_62_1_2004,52 -sports_entertainment_sports_arena,level_3_ventilation_62_1_2004,53 -sports_entertainment_gym_stadium,level_3_ventilation_62_1_2004,54 -sports_entertainment_spectator_areas,level_3_ventilation_62_1_2004,55 -sports_entertainment_swimming,level_3_ventilation_62_1_2004,56 -sports_entertainment_disco_dance_floors,level_3_ventilation_62_1_2004,57 -sports_entertainment_health_club_aerobics_room,level_3_ventilation_62_1_2004,58 -sports_entertainment_health_club_weight_rooms,level_3_ventilation_62_1_2004,59 -sports_entertainment_bowling_alley,level_3_ventilation_62_1_2004,60 -sports_entertainment_gambling_casinos,level_3_ventilation_62_1_2004,61 -sports_entertainment_game_arcades,level_3_ventilation_62_1_2004,62 -sports_entertainment_stages_studios,level_3_ventilation_62_1_2004,63 +airport_concourse_ventilation,level_3_ventilation_62_1_2019,63 +atrium_ventilation,level_3_ventilation_62_1_2019,60 +attic_ventilation,level_3_ventilation_62_1_2019,110 +audience_seating_ventilation,level_3_ventilation_62_1_2019,83 +baggage_carousel_ventilation,level_3_ventilation_62_1_2019,63 +banking_ventilation,level_3_ventilation_62_1_2019,46 +classroom_lecture_training_ventilation,level_3_ventilation_62_1_2019,18 +computer_room_ventilation,level_3_ventilation_62_1_2019,19 +conference_meeting_multipurpose_ventilation,level_3_ventilation_62_1_2019,37 +confinement_cells_ventilation,level_3_ventilation_62_1_2019,13 +copy_print_ventilation,level_3_ventilation_62_1_2019,64 +corridor_ventilation,level_3_ventilation_62_1_2019,38 +courtroom_ventilation,level_3_ventilation_62_1_2019,84 +datacenterhighite_ventilation,level_3_ventilation_62_1_2019,110 +datacenterlowite_ventilation,level_3_ventilation_62_1_2019,110 +dining_ventilation,level_3_ventilation_62_1_2019,34 +dressing_room_ventilation,level_3_ventilation_62_1_2019,95 +electrical_mechanical_ventilation,level_3_ventilation_62_1_2019,110 +emergency_room_ventilation,level_3_ventilation_62_1_2019,79 +exam_treatment_ventilation,level_3_ventilation_62_1_2019,68 +exercise_area_ventilation,level_3_ventilation_62_1_2019,103 +exhibit_ventilation,level_3_ventilation_62_1_2019,89 +guest_room_ventilation,level_3_ventilation_62_1_2019,41 +imaging_ventilation,level_3_ventilation_62_1_2019,66 +judges_chambers_ventilation,level_3_ventilation_62_1_2019,85 +food_preparation_ventilation,level_3_ventilation_62_1_2019,33 +laboratory_ventilation,level_3_ventilation_62_1_2019,28 +laundry_washing_ventilation,level_3_ventilation_62_1_2019,42 +library_ventilation,level_3_ventilation_62_1_2019,86 +living_quarters_ventilation,level_3_ventilation_62_1_2019,40 +loading_dock_ventilation,level_3_ventilation_62_1_2019,54 +lobby_ventilation,level_3_ventilation_62_1_2019,60 +locker_room_ventilation,level_3_ventilation_62_1_2019,35 +lounge_breakroom_ventilation,level_3_ventilation_62_1_2019,35 +manufacturing_ventilation,level_3_ventilation_62_1_2019,50 +medical_supply_ventilation,level_3_ventilation_62_1_2019,52 +multifamily_ventilation,level_3_ventilation_62_1_2019,41 +nursery_ventilation,level_3_ventilation_62_1_2019,65 +nurses_station_ventilation,level_3_ventilation_62_1_2019,63 +office_ventilation,level_3_ventilation_62_1_2019,62 +office_enclosed_ventilation,level_3_ventilation_62_1_2019,62 +operating_room_ventilation,level_3_ventilation_62_1_2019,81 +patient_room_ventilation,level_3_ventilation_62_1_2019,80 +pharmacy_ventilation,level_3_ventilation_62_1_2019,52 +physical_therapy_ventilation,level_3_ventilation_62_1_2019,70 +playing_area_ventilation,level_3_ventilation_62_1_2019,102 +plenum_ventilation,level_3_ventilation_62_1_2019,110 +post_office_ventilation,level_3_ventilation_62_1_2019,54 +recovery_ventilation,level_3_ventilation_62_1_2019,80 +recreation_common_living_ventilation,level_3_ventilation_62_1_2019,45 +retail_sales_ventilation,level_3_ventilation_62_1_2019,91 +shaft_ventilation,level_3_ventilation_62_1_2019,110 +sleeping_quarters_ventilation,level_3_ventilation_62_1_2019,40 +sports_arena_ventilation,level_3_ventilation_62_1_2019,102 +stairwell_ventilation,level_3_ventilation_62_1_2019,110 +storage_ventilation,level_3_ventilation_62_1_2019,61 +transportation_ventilation,level_3_ventilation_62_1_2019,57 +workshop_ventilation,level_3_ventilation_62_1_2019,50 +worship_ventilation,level_3_ventilation_62_1_2019,90 +correctional_facilities_booking_waiting_ventilation,level_3_ventilation_62_1_2019,12 +correctional_facilities_day_room_ventilation,level_3_ventilation_62_1_2019,14 +correctional_facilities_guard_stations_ventilation,level_3_ventilation_62_1_2019,15 +educational_facilities_art_classroom_ventilation,level_3_ventilation_62_1_2019,16 +educational_facilities_classrooms_ages_5-8_ventilation,level_3_ventilation_62_1_2019,17 +educational_facilities_daycare_through_age_4_ventilation,level_3_ventilation_62_1_2019,21 +educational_facilities_lecture_classroom_ventilation,level_3_ventilation_62_1_2019,22 +educational_facilities_lecture_hall_fixed_seats_ventilation,level_3_ventilation_62_1_2019,23 +educational_facilities_media_center_ventilation,level_3_ventilation_62_1_2019,25 +educational_facilities_multi-use_assembly_ventilation,level_3_ventilation_62_1_2019,26 +educational_facilities_music_theater_dance_ventilation,level_3_ventilation_62_1_2019,27 +educational_facilities_science_laboratories_ventilation,level_3_ventilation_62_1_2019,29 +educational_facilities_wood_metal_shop_ventilation,level_3_ventilation_62_1_2019,30 +food_and_beverage_service_bars_cocktail_lounges_ventilation,level_3_ventilation_62_1_2019,31 +food_and_beverage_service_cafeteria_fast_food_dining_ventilation,level_3_ventilation_62_1_2019,32 +hotels_motels_resorts_dormitories_lobbies_prefunction_ventilation,level_3_ventilation_62_1_2019,44 +miscellaneous_spaces_bank_vaults_safe_deposit_ventilation,level_3_ventilation_62_1_2019,47 +miscellaneous_spaces_computer_not_printing_ventilation,level_3_ventilation_62_1_2019,48 +miscellaneous_spaces_photo_studios_ventilation,level_3_ventilation_62_1_2019,53 +miscellaneous_spaces_warehouses_ventilation,level_3_ventilation_62_1_2019,58 +public_assembly_spaces_lobbies_ventilation,level_3_ventilation_62_1_2019,87 +public_assembly_spaces_museums_childrens_ventilation,level_3_ventilation_62_1_2019,88 +retail_barber_shop_ventilation,level_3_ventilation_62_1_2019,92 +retail_beauty_and_nail_salons_ventilation,level_3_ventilation_62_1_2019,93 +retail_coin-operated_laundries_ventilation,level_3_ventilation_62_1_2019,94 +retail_pet_shops_animal_areas_ventilation,level_3_ventilation_62_1_2019,96 +retail_supermarket_ventilation,level_3_ventilation_62_1_2019,97 +sports_and_entertainment_bowling_alley_seating_ventilation,level_3_ventilation_62_1_2019,98 +sports_and_entertainment_disco_dance_floors_ventilation,level_3_ventilation_62_1_2019,99 +sports_and_entertainment_gambling_casinos_ventilation,level_3_ventilation_62_1_2019,100 +sports_and_entertainment_game_arcades_ventilation,level_3_ventilation_62_1_2019,101 +sports_and_entertainment_health_club_weight_rooms_ventilation,level_3_ventilation_62_1_2019,104 +sports_and_entertainment_spectator_areas_ventilation,level_3_ventilation_62_1_2019,105 +sports_and_entertainment_stages_studios_ventilation,level_3_ventilation_62_1_2019,106 +sports_and_entertainment_swimming_pool_deck_ventilation,level_3_ventilation_62_1_2019,107 +airport_concourse_ventilation,level_3_ventilation_62_1_2016,50 +atrium_ventilation,level_3_ventilation_62_1_2016,47 +attic_ventilation,level_3_ventilation_62_1_2016,79 +audience_seating_ventilation,level_3_ventilation_62_1_2016,52 +baggage_carousel_ventilation,level_3_ventilation_62_1_2016,50 +banking_ventilation,level_3_ventilation_62_1_2016,35 +classroom_lecture_training_ventilation,level_3_ventilation_62_1_2016,8 +computer_room_ventilation,level_3_ventilation_62_1_2016,15 +conference_meeting_multipurpose_ventilation,level_3_ventilation_62_1_2016,25 +confinement_cells_ventilation,level_3_ventilation_62_1_2016,1 +copy_print_ventilation,level_3_ventilation_62_1_2016,51 +corridor_ventilation,level_3_ventilation_62_1_2016,26 +courtroom_ventilation,level_3_ventilation_62_1_2016,54 +datacenterhighite_ventilation,level_3_ventilation_62_1_2016,79 +datacenterlowite_ventilation,level_3_ventilation_62_1_2016,79 +dining_ventilation,level_3_ventilation_62_1_2016,19 +dressing_room_ventilation,level_3_ventilation_62_1_2016,63 +electrical_mechanical_ventilation,level_3_ventilation_62_1_2016,79 +exercise_area_ventilation,level_3_ventilation_62_1_2016,73 +exhibit_ventilation,level_3_ventilation_62_1_2016,59 +guest_room_ventilation,level_3_ventilation_62_1_2016,28 +judges_chambers_ventilation,level_3_ventilation_62_1_2016,55 +food_preparation_ventilation,level_3_ventilation_62_1_2016,22 +laboratory_ventilation,level_3_ventilation_62_1_2016,12 +laundry_washing_ventilation,level_3_ventilation_62_1_2016,30 +library_ventilation,level_3_ventilation_62_1_2016,56 +living_quarters_ventilation,level_3_ventilation_62_1_2016,29 +loading_dock_ventilation,level_3_ventilation_62_1_2016,41 +lobby_ventilation,level_3_ventilation_62_1_2016,47 +locker_room_ventilation,level_3_ventilation_62_1_2016,23 +lounge_breakroom_ventilation,level_3_ventilation_62_1_2016,23 +medical_supply_ventilation,level_3_ventilation_62_1_2016,39 +multifamily_ventilation,level_3_ventilation_62_1_2016,28 +nurses_station_ventilation,level_3_ventilation_62_1_2016,50 +office_ventilation,level_3_ventilation_62_1_2016,49 +office_enclosed_ventilation,level_3_ventilation_62_1_2016,49 +pharmacy_ventilation,level_3_ventilation_62_1_2016,39 +playing_area_ventilation,level_3_ventilation_62_1_2016,69 +plenum_ventilation,level_3_ventilation_62_1_2016,79 +post_office_ventilation,level_3_ventilation_62_1_2016,41 +recreation_common_living_ventilation,level_3_ventilation_62_1_2016,33 +retail_sales_ventilation,level_3_ventilation_62_1_2016,62 +shaft_ventilation,level_3_ventilation_62_1_2016,79 +sleeping_quarters_ventilation,level_3_ventilation_62_1_2016,29 +sports_arena_ventilation,level_3_ventilation_62_1_2016,69 +stairwell_ventilation,level_3_ventilation_62_1_2016,79 +storage_ventilation,level_3_ventilation_62_1_2016,48 +transportation_ventilation,level_3_ventilation_62_1_2016,44 +worship_ventilation,level_3_ventilation_62_1_2016,53 +correctional_facilities_booking_waiting_ventilation,level_3_ventilation_62_1_2016,4 +correctional_facilities_day_room_ventilation,level_3_ventilation_62_1_2016,2 +correctional_facilities_guard_stations_ventilation,level_3_ventilation_62_1_2016,3 +educational_facilities_art_classroom_ventilation,level_3_ventilation_62_1_2016,11 +educational_facilities_classrooms_ages_5-8_ventilation,level_3_ventilation_62_1_2016,7 +educational_facilities_daycare_through_age_4_ventilation,level_3_ventilation_62_1_2016,5 +educational_facilities_lecture_classroom_ventilation,level_3_ventilation_62_1_2016,9 +educational_facilities_lecture_hall_fixed_seats_ventilation,level_3_ventilation_62_1_2016,10 +educational_facilities_media_center_ventilation,level_3_ventilation_62_1_2016,16 +educational_facilities_multi-use_assembly_ventilation,level_3_ventilation_62_1_2016,18 +educational_facilities_music_theater_dance_ventilation,level_3_ventilation_62_1_2016,17 +educational_facilities_science_laboratories_ventilation,level_3_ventilation_62_1_2016,13 +educational_facilities_wood_metal_shop_ventilation,level_3_ventilation_62_1_2016,14 +food_and_beverage_service_bars_cocktail_lounges_ventilation,level_3_ventilation_62_1_2016,21 +food_and_beverage_service_cafeteria_fast_food_dining_ventilation,level_3_ventilation_62_1_2016,20 +hotels_motels_resorts_dormitories_lobbies_prefunction_ventilation,level_3_ventilation_62_1_2016,32 +miscellaneous_spaces_bank_vaults_safe_deposit_ventilation,level_3_ventilation_62_1_2016,34 +miscellaneous_spaces_computer_not_printing_ventilation,level_3_ventilation_62_1_2016,36 +miscellaneous_spaces_photo_studios_ventilation,level_3_ventilation_62_1_2016,40 +miscellaneous_spaces_warehouses_ventilation,level_3_ventilation_62_1_2016,45 +public_assembly_spaces_lobbies_ventilation,level_3_ventilation_62_1_2016,57 +public_assembly_spaces_museums_childrens_ventilation,level_3_ventilation_62_1_2016,58 +retail_barber_shop_ventilation,level_3_ventilation_62_1_2016,64 +retail_beauty_and_nail_salons_ventilation,level_3_ventilation_62_1_2016,65 +retail_coin-operated_laundries_ventilation,level_3_ventilation_62_1_2016,68 +retail_pet_shops_animal_areas_ventilation,level_3_ventilation_62_1_2016,66 +retail_supermarket_ventilation,level_3_ventilation_62_1_2016,67 +sports_and_entertainment_bowling_alley_seating_ventilation,level_3_ventilation_62_1_2016,75 +sports_and_entertainment_disco_dance_floors_ventilation,level_3_ventilation_62_1_2016,72 +sports_and_entertainment_gambling_casinos_ventilation,level_3_ventilation_62_1_2016,76 +sports_and_entertainment_game_arcades_ventilation,level_3_ventilation_62_1_2016,77 +sports_and_entertainment_health_club_weight_rooms_ventilation,level_3_ventilation_62_1_2016,74 +sports_and_entertainment_spectator_areas_ventilation,level_3_ventilation_62_1_2016,70 +sports_and_entertainment_stages_studios_ventilation,level_3_ventilation_62_1_2016,78 +sports_and_entertainment_swimming_pool_deck_ventilation,level_3_ventilation_62_1_2016,71 +airport_concourse_ventilation,level_3_ventilation_62_1_2013,50 +atrium_ventilation,level_3_ventilation_62_1_2013,47 +attic_ventilation,level_3_ventilation_62_1_2013,79 +audience_seating_ventilation,level_3_ventilation_62_1_2013,52 +baggage_carousel_ventilation,level_3_ventilation_62_1_2013,50 +banking_ventilation,level_3_ventilation_62_1_2013,35 +classroom_lecture_training_ventilation,level_3_ventilation_62_1_2013,8 +computer_room_ventilation,level_3_ventilation_62_1_2013,15 +conference_meeting_multipurpose_ventilation,level_3_ventilation_62_1_2013,25 +confinement_cells_ventilation,level_3_ventilation_62_1_2013,1 +copy_print_ventilation,level_3_ventilation_62_1_2013,51 +corridor_ventilation,level_3_ventilation_62_1_2013,26 +courtroom_ventilation,level_3_ventilation_62_1_2013,54 +datacenterhighite_ventilation,level_3_ventilation_62_1_2013,79 +datacenterlowite_ventilation,level_3_ventilation_62_1_2013,79 +dining_ventilation,level_3_ventilation_62_1_2013,19 +dressing_room_ventilation,level_3_ventilation_62_1_2013,63 +electrical_mechanical_ventilation,level_3_ventilation_62_1_2013,79 +exercise_area_ventilation,level_3_ventilation_62_1_2013,73 +exhibit_ventilation,level_3_ventilation_62_1_2013,59 +guest_room_ventilation,level_3_ventilation_62_1_2013,28 +judges_chambers_ventilation,level_3_ventilation_62_1_2013,55 +food_preparation_ventilation,level_3_ventilation_62_1_2013,22 +laboratory_ventilation,level_3_ventilation_62_1_2013,12 +laundry_washing_ventilation,level_3_ventilation_62_1_2013,30 +library_ventilation,level_3_ventilation_62_1_2013,56 +living_quarters_ventilation,level_3_ventilation_62_1_2013,29 +loading_dock_ventilation,level_3_ventilation_62_1_2013,41 +lobby_ventilation,level_3_ventilation_62_1_2013,47 +locker_room_ventilation,level_3_ventilation_62_1_2013,23 +lounge_breakroom_ventilation,level_3_ventilation_62_1_2013,23 +medical_supply_ventilation,level_3_ventilation_62_1_2013,39 +multifamily_ventilation,level_3_ventilation_62_1_2013,28 +nurses_station_ventilation,level_3_ventilation_62_1_2013,50 +office_ventilation,level_3_ventilation_62_1_2013,49 +office_enclosed_ventilation,level_3_ventilation_62_1_2013,49 +pharmacy_ventilation,level_3_ventilation_62_1_2013,39 +playing_area_ventilation,level_3_ventilation_62_1_2013,69 +plenum_ventilation,level_3_ventilation_62_1_2013,79 +post_office_ventilation,level_3_ventilation_62_1_2013,41 +recreation_common_living_ventilation,level_3_ventilation_62_1_2013,33 +retail_sales_ventilation,level_3_ventilation_62_1_2013,62 +shaft_ventilation,level_3_ventilation_62_1_2013,79 +sleeping_quarters_ventilation,level_3_ventilation_62_1_2013,29 +sports_arena_ventilation,level_3_ventilation_62_1_2013,69 +stairwell_ventilation,level_3_ventilation_62_1_2013,79 +storage_ventilation,level_3_ventilation_62_1_2013,48 +transportation_ventilation,level_3_ventilation_62_1_2013,44 +worship_ventilation,level_3_ventilation_62_1_2013,53 +correctional_facilities_booking_waiting_ventilation,level_3_ventilation_62_1_2013,4 +correctional_facilities_day_room_ventilation,level_3_ventilation_62_1_2013,2 +correctional_facilities_guard_stations_ventilation,level_3_ventilation_62_1_2013,3 +educational_facilities_art_classroom_ventilation,level_3_ventilation_62_1_2013,11 +educational_facilities_classrooms_ages_5-8_ventilation,level_3_ventilation_62_1_2013,7 +educational_facilities_daycare_through_age_4_ventilation,level_3_ventilation_62_1_2013,5 +educational_facilities_lecture_classroom_ventilation,level_3_ventilation_62_1_2013,9 +educational_facilities_lecture_hall_fixed_seats_ventilation,level_3_ventilation_62_1_2013,10 +educational_facilities_media_center_ventilation,level_3_ventilation_62_1_2013,16 +educational_facilities_multi-use_assembly_ventilation,level_3_ventilation_62_1_2013,18 +educational_facilities_music_theater_dance_ventilation,level_3_ventilation_62_1_2013,17 +educational_facilities_science_laboratories_ventilation,level_3_ventilation_62_1_2013,12 +educational_facilities_wood_metal_shop_ventilation,level_3_ventilation_62_1_2013,14 +food_and_beverage_service_bars_cocktail_lounges_ventilation,level_3_ventilation_62_1_2013,21 +food_and_beverage_service_cafeteria_fast_food_dining_ventilation,level_3_ventilation_62_1_2013,20 +hotels_motels_resorts_dormitories_lobbies_prefunction_ventilation,level_3_ventilation_62_1_2013,32 +miscellaneous_spaces_bank_vaults_safe_deposit_ventilation,level_3_ventilation_62_1_2013,34 +miscellaneous_spaces_computer_not_printing_ventilation,level_3_ventilation_62_1_2013,36 +miscellaneous_spaces_photo_studios_ventilation,level_3_ventilation_62_1_2013,40 +miscellaneous_spaces_warehouses_ventilation,level_3_ventilation_62_1_2013,45 +public_assembly_spaces_lobbies_ventilation,level_3_ventilation_62_1_2013,57 +public_assembly_spaces_museums_childrens_ventilation,level_3_ventilation_62_1_2013,58 +retail_barber_shop_ventilation,level_3_ventilation_62_1_2013,64 +retail_beauty_and_nail_salons_ventilation,level_3_ventilation_62_1_2013,65 +retail_coin-operated_laundries_ventilation,level_3_ventilation_62_1_2013,68 +retail_pet_shops_animal_areas_ventilation,level_3_ventilation_62_1_2013,66 +retail_supermarket_ventilation,level_3_ventilation_62_1_2013,67 +sports_and_entertainment_bowling_alley_seating_ventilation,level_3_ventilation_62_1_2013,75 +sports_and_entertainment_disco_dance_floors_ventilation,level_3_ventilation_62_1_2013,72 +sports_and_entertainment_gambling_casinos_ventilation,level_3_ventilation_62_1_2013,76 +sports_and_entertainment_game_arcades_ventilation,level_3_ventilation_62_1_2013,77 +sports_and_entertainment_health_club_weight_rooms_ventilation,level_3_ventilation_62_1_2013,74 +sports_and_entertainment_spectator_areas_ventilation,level_3_ventilation_62_1_2013,70 +sports_and_entertainment_stages_studios_ventilation,level_3_ventilation_62_1_2013,78 +sports_and_entertainment_swimming_pool_deck_ventilation,level_3_ventilation_62_1_2013,71 +airport_concourse_ventilation,level_3_ventilation_62_1_2010,38 +atrium_ventilation,level_3_ventilation_62_1_2010,35 +attic_ventilation,level_3_ventilation_62_1_2010,79 +audience_seating_ventilation,level_3_ventilation_62_1_2010,51 +baggage_carousel_ventilation,level_3_ventilation_62_1_2010,38 +banking_ventilation,level_3_ventilation_62_1_2010,41 +classroom_lecture_training_ventilation,level_3_ventilation_62_1_2010,8 +computer_room_ventilation,level_3_ventilation_62_1_2010,15 +conference_meeting_multipurpose_ventilation,level_3_ventilation_62_1_2010,25 +confinement_cells_ventilation,level_3_ventilation_62_1_2010,1 +copy_print_ventilation,level_3_ventilation_62_1_2010,39 +corridor_ventilation,level_3_ventilation_62_1_2010,26 +courtroom_ventilation,level_3_ventilation_62_1_2010,53 +datacenterhighite_ventilation,level_3_ventilation_62_1_2010,79 +datacenterlowite_ventilation,level_3_ventilation_62_1_2010,79 +dining_ventilation,level_3_ventilation_62_1_2010,19 +dressing_room_ventilation,level_3_ventilation_62_1_2010,62 +electrical_mechanical_ventilation,level_3_ventilation_62_1_2010,79 +exercise_area_ventilation,level_3_ventilation_62_1_2010,73 +exhibit_ventilation,level_3_ventilation_62_1_2010,58 +guest_room_ventilation,level_3_ventilation_62_1_2010,28 +judges_chambers_ventilation,level_3_ventilation_62_1_2010,54 +food_preparation_ventilation,level_3_ventilation_62_1_2010,22 +laboratory_ventilation,level_3_ventilation_62_1_2010,12 +laundry_washing_ventilation,level_3_ventilation_62_1_2010,30 +library_ventilation,level_3_ventilation_62_1_2010,55 +living_quarters_ventilation,level_3_ventilation_62_1_2010,29 +loading_dock_ventilation,level_3_ventilation_62_1_2010,46 +lobby_ventilation,level_3_ventilation_62_1_2010,35 +locker_room_ventilation,level_3_ventilation_62_1_2010,23 +lounge_breakroom_ventilation,level_3_ventilation_62_1_2010,23 +medical_supply_ventilation,level_3_ventilation_62_1_2010,44 +multifamily_ventilation,level_3_ventilation_62_1_2010,28 +nurses_station_ventilation,level_3_ventilation_62_1_2010,38 +office_ventilation,level_3_ventilation_62_1_2010,37 +office_enclosed_ventilation,level_3_ventilation_62_1_2010,37 +pharmacy_ventilation,level_3_ventilation_62_1_2010,44 +playing_area_ventilation,level_3_ventilation_62_1_2010,69 +plenum_ventilation,level_3_ventilation_62_1_2010,79 +post_office_ventilation,level_3_ventilation_62_1_2010,46 +recreation_common_living_ventilation,level_3_ventilation_62_1_2010,33 +retail_sales_ventilation,level_3_ventilation_62_1_2010,61 +shaft_ventilation,level_3_ventilation_62_1_2010,79 +sleeping_quarters_ventilation,level_3_ventilation_62_1_2010,29 +sports_arena_ventilation,level_3_ventilation_62_1_2010,68 +stairwell_ventilation,level_3_ventilation_62_1_2010,79 +storage_ventilation,level_3_ventilation_62_1_2010,36 +transportation_ventilation,level_3_ventilation_62_1_2010,49 +worship_ventilation,level_3_ventilation_62_1_2010,52 +correctional_facilities_booking_waiting_ventilation,level_3_ventilation_62_1_2010,4 +correctional_facilities_day_room_ventilation,level_3_ventilation_62_1_2010,2 +correctional_facilities_guard_stations_ventilation,level_3_ventilation_62_1_2010,3 +educational_facilities_art_classroom_ventilation,level_3_ventilation_62_1_2010,11 +educational_facilities_classrooms_ages_5-8_ventilation,level_3_ventilation_62_1_2010,7 +educational_facilities_daycare_through_age_4_ventilation,level_3_ventilation_62_1_2010,5 +educational_facilities_lecture_classroom_ventilation,level_3_ventilation_62_1_2010,9 +educational_facilities_lecture_hall_fixed_seats_ventilation,level_3_ventilation_62_1_2010,10 +educational_facilities_media_center_ventilation,level_3_ventilation_62_1_2010,16 +educational_facilities_multi-use_assembly_ventilation,level_3_ventilation_62_1_2010,18 +educational_facilities_music_theater_dance_ventilation,level_3_ventilation_62_1_2010,17 +educational_facilities_science_laboratories_ventilation,level_3_ventilation_62_1_2010,12 +educational_facilities_wood_metal_shop_ventilation,level_3_ventilation_62_1_2010,14 +food_and_beverage_service_bars_cocktail_lounges_ventilation,level_3_ventilation_62_1_2010,21 +food_and_beverage_service_cafeteria_fast_food_dining_ventilation,level_3_ventilation_62_1_2010,20 +hotels_motels_resorts_dormitories_lobbies_prefunction_ventilation,level_3_ventilation_62_1_2010,32 +miscellaneous_spaces_bank_vaults_safe_deposit_ventilation,level_3_ventilation_62_1_2010,40 +miscellaneous_spaces_computer_not_printing_ventilation,level_3_ventilation_62_1_2010,42 +miscellaneous_spaces_photo_studios_ventilation,level_3_ventilation_62_1_2010,45 +miscellaneous_spaces_warehouses_ventilation,level_3_ventilation_62_1_2010,50 +public_assembly_spaces_lobbies_ventilation,level_3_ventilation_62_1_2010,56 +public_assembly_spaces_museums_childrens_ventilation,level_3_ventilation_62_1_2010,57 +retail_barber_shop_ventilation,level_3_ventilation_62_1_2010,63 +retail_beauty_and_nail_salons_ventilation,level_3_ventilation_62_1_2010,64 +retail_coin-operated_laundries_ventilation,level_3_ventilation_62_1_2010,67 +retail_pet_shops_animal_areas_ventilation,level_3_ventilation_62_1_2010,65 +retail_supermarket_ventilation,level_3_ventilation_62_1_2010,66 +sports_and_entertainment_bowling_alley_seating_ventilation,level_3_ventilation_62_1_2010,75 +sports_and_entertainment_disco_dance_floors_ventilation,level_3_ventilation_62_1_2010,72 +sports_and_entertainment_gambling_casinos_ventilation,level_3_ventilation_62_1_2010,76 +sports_and_entertainment_game_arcades_ventilation,level_3_ventilation_62_1_2010,77 +sports_and_entertainment_health_club_weight_rooms_ventilation,level_3_ventilation_62_1_2010,74 +sports_and_entertainment_spectator_areas_ventilation,level_3_ventilation_62_1_2010,70 +sports_and_entertainment_stages_studios_ventilation,level_3_ventilation_62_1_2010,78 +sports_and_entertainment_swimming_pool_deck_ventilation,level_3_ventilation_62_1_2010,71 +airport_concourse_ventilation,level_3_ventilation_62_1_2007,34 +atrium_ventilation,level_3_ventilation_62_1_2007,36 +attic_ventilation,level_3_ventilation_62_1_2007,75 +audience_seating_ventilation,level_3_ventilation_62_1_2007,47 +baggage_carousel_ventilation,level_3_ventilation_62_1_2007,34 +banking_ventilation,level_3_ventilation_62_1_2007,34 +classroom_lecture_training_ventilation,level_3_ventilation_62_1_2007,8 +computer_room_ventilation,level_3_ventilation_62_1_2007,15 +conference_meeting_multipurpose_ventilation,level_3_ventilation_62_1_2007,24 +confinement_cells_ventilation,level_3_ventilation_62_1_2007,1 +copy_print_ventilation,level_3_ventilation_62_1_2007,35 +corridor_ventilation,level_3_ventilation_62_1_2007,25 +courtroom_ventilation,level_3_ventilation_62_1_2007,49 +datacenterhighite_ventilation,level_3_ventilation_62_1_2007,75 +datacenterlowite_ventilation,level_3_ventilation_62_1_2007,75 +dining_ventilation,level_3_ventilation_62_1_2007,19 +dressing_room_ventilation,level_3_ventilation_62_1_2007,58 +electrical_mechanical_ventilation,level_3_ventilation_62_1_2007,75 +exercise_area_ventilation,level_3_ventilation_62_1_2007,69 +exhibit_ventilation,level_3_ventilation_62_1_2007,54 +guest_room_ventilation,level_3_ventilation_62_1_2007,27 +judges_chambers_ventilation,level_3_ventilation_62_1_2007,50 +laboratory_ventilation,level_3_ventilation_62_1_2007,12 +laundry_washing_ventilation,level_3_ventilation_62_1_2007,29 +library_ventilation,level_3_ventilation_62_1_2007,51 +living_quarters_ventilation,level_3_ventilation_62_1_2007,28 +loading_dock_ventilation,level_3_ventilation_62_1_2007,43 +lobby_ventilation,level_3_ventilation_62_1_2007,36 +locker_room_ventilation,level_3_ventilation_62_1_2007,22 +lounge_breakroom_ventilation,level_3_ventilation_62_1_2007,22 +medical_supply_ventilation,level_3_ventilation_62_1_2007,41 +multifamily_ventilation,level_3_ventilation_62_1_2007,27 +nurses_station_ventilation,level_3_ventilation_62_1_2007,34 +office_ventilation,level_3_ventilation_62_1_2007,33 +office_enclosed_ventilation,level_3_ventilation_62_1_2007,33 +pharmacy_ventilation,level_3_ventilation_62_1_2007,41 +playing_area_ventilation,level_3_ventilation_62_1_2007,65 +plenum_ventilation,level_3_ventilation_62_1_2007,75 +post_office_ventilation,level_3_ventilation_62_1_2007,43 +recreation_common_living_ventilation,level_3_ventilation_62_1_2007,32 +retail_sales_ventilation,level_3_ventilation_62_1_2007,57 +shaft_ventilation,level_3_ventilation_62_1_2007,75 +sleeping_quarters_ventilation,level_3_ventilation_62_1_2007,28 +sports_arena_ventilation,level_3_ventilation_62_1_2007,64 +stairwell_ventilation,level_3_ventilation_62_1_2007,75 +storage_ventilation,level_3_ventilation_62_1_2007,26 +transportation_ventilation,level_3_ventilation_62_1_2007,45 +worship_ventilation,level_3_ventilation_62_1_2007,48 +correctional_facilities_booking_waiting_ventilation,level_3_ventilation_62_1_2007,4 +correctional_facilities_day_room_ventilation,level_3_ventilation_62_1_2007,2 +correctional_facilities_guard_stations_ventilation,level_3_ventilation_62_1_2007,3 +educational_facilities_art_classroom_ventilation,level_3_ventilation_62_1_2007,11 +educational_facilities_classrooms_ages_5-8_ventilation,level_3_ventilation_62_1_2007,7 +educational_facilities_daycare_through_age_4_ventilation,level_3_ventilation_62_1_2007,5 +educational_facilities_lecture_classroom_ventilation,level_3_ventilation_62_1_2007,9 +educational_facilities_lecture_hall_fixed_seats_ventilation,level_3_ventilation_62_1_2007,10 +educational_facilities_media_center_ventilation,level_3_ventilation_62_1_2007,16 +educational_facilities_multi-use_assembly_ventilation,level_3_ventilation_62_1_2007,18 +educational_facilities_music_theater_dance_ventilation,level_3_ventilation_62_1_2007,17 +educational_facilities_science_laboratories_ventilation,level_3_ventilation_62_1_2007,12 +educational_facilities_wood_metal_shop_ventilation,level_3_ventilation_62_1_2007,14 +food_and_beverage_service_bars_cocktail_lounges_ventilation,level_3_ventilation_62_1_2007,21 +food_and_beverage_service_cafeteria_fast_food_dining_ventilation,level_3_ventilation_62_1_2007,20 +hotels_motels_resorts_dormitories_lobbies_prefunction_ventilation,level_3_ventilation_62_1_2007,31 +miscellaneous_spaces_bank_vaults_safe_deposit_ventilation,level_3_ventilation_62_1_2007,37 +miscellaneous_spaces_computer_not_printing_ventilation,level_3_ventilation_62_1_2007,38 +miscellaneous_spaces_photo_studios_ventilation,level_3_ventilation_62_1_2007,42 +miscellaneous_spaces_warehouses_ventilation,level_3_ventilation_62_1_2007,46 +public_assembly_spaces_lobbies_ventilation,level_3_ventilation_62_1_2007,52 +public_assembly_spaces_museums_childrens_ventilation,level_3_ventilation_62_1_2007,53 +retail_barber_shop_ventilation,level_3_ventilation_62_1_2007,59 +retail_beauty_and_nail_salons_ventilation,level_3_ventilation_62_1_2007,60 +retail_coin-operated_laundries_ventilation,level_3_ventilation_62_1_2007,63 +retail_pet_shops_animal_areas_ventilation,level_3_ventilation_62_1_2007,61 +retail_supermarket_ventilation,level_3_ventilation_62_1_2007,62 +sports_and_entertainment_bowling_alley_seating_ventilation,level_3_ventilation_62_1_2007,71 +sports_and_entertainment_disco_dance_floors_ventilation,level_3_ventilation_62_1_2007,68 +sports_and_entertainment_gambling_casinos_ventilation,level_3_ventilation_62_1_2007,72 +sports_and_entertainment_game_arcades_ventilation,level_3_ventilation_62_1_2007,73 +sports_and_entertainment_health_club_weight_rooms_ventilation,level_3_ventilation_62_1_2007,70 +sports_and_entertainment_spectator_areas_ventilation,level_3_ventilation_62_1_2007,66 +sports_and_entertainment_stages_studios_ventilation,level_3_ventilation_62_1_2007,74 +sports_and_entertainment_swimming_pool_deck_ventilation,level_3_ventilation_62_1_2007,67 +airport_concourse_ventilation,level_3_ventilation_62_1_2004,28 +atrium_ventilation,level_3_ventilation_62_1_2004,30 +attic_ventilation,level_3_ventilation_62_1_2004,64 +audience_seating_ventilation,level_3_ventilation_62_1_2004,38 +baggage_carousel_ventilation,level_3_ventilation_62_1_2004,28 +banking_ventilation,level_3_ventilation_62_1_2004,28 +classroom_lecture_training_ventilation,level_3_ventilation_62_1_2004,7 +computer_room_ventilation,level_3_ventilation_62_1_2004,13 +conference_meeting_multipurpose_ventilation,level_3_ventilation_62_1_2004,20 +confinement_cells_ventilation,level_3_ventilation_62_1_2004,1 +copy_print_ventilation,level_3_ventilation_62_1_2004,29 +corridor_ventilation,level_3_ventilation_62_1_2004,21 +courtroom_ventilation,level_3_ventilation_62_1_2004,40 +datacenterhighite_ventilation,level_3_ventilation_62_1_2004,64 +datacenterlowite_ventilation,level_3_ventilation_62_1_2004,64 +dining_ventilation,level_3_ventilation_62_1_2004,17 +dressing_room_ventilation,level_3_ventilation_62_1_2004,47 +electrical_mechanical_ventilation,level_3_ventilation_62_1_2004,64 +exercise_area_ventilation,level_3_ventilation_62_1_2004,58 +exhibit_ventilation,level_3_ventilation_62_1_2004,45 +guest_room_ventilation,level_3_ventilation_62_1_2004,23 +judges_chambers_ventilation,level_3_ventilation_62_1_2004,41 +laboratory_ventilation,level_3_ventilation_62_1_2004,11 +library_ventilation,level_3_ventilation_62_1_2004,42 +living_quarters_ventilation,level_3_ventilation_62_1_2004,24 +loading_dock_ventilation,level_3_ventilation_62_1_2004,35 +lobby_ventilation,level_3_ventilation_62_1_2004,30 +medical_supply_ventilation,level_3_ventilation_62_1_2004,33 +multifamily_ventilation,level_3_ventilation_62_1_2004,23 +nurses_station_ventilation,level_3_ventilation_62_1_2004,28 +office_ventilation,level_3_ventilation_62_1_2004,27 +office_enclosed_ventilation,level_3_ventilation_62_1_2004,27 +pharmacy_ventilation,level_3_ventilation_62_1_2004,33 +playing_area_ventilation,level_3_ventilation_62_1_2004,53 +plenum_ventilation,level_3_ventilation_62_1_2004,64 +post_office_ventilation,level_3_ventilation_62_1_2004,35 +recreation_common_living_ventilation,level_3_ventilation_62_1_2004,26 +retail_sales_ventilation,level_3_ventilation_62_1_2004,46 +shaft_ventilation,level_3_ventilation_62_1_2004,64 +sleeping_quarters_ventilation,level_3_ventilation_62_1_2004,24 +sports_arena_ventilation,level_3_ventilation_62_1_2004,53 +stairwell_ventilation,level_3_ventilation_62_1_2004,64 +storage_ventilation,level_3_ventilation_62_1_2004,22 +transportation_ventilation,level_3_ventilation_62_1_2004,36 +worship_ventilation,level_3_ventilation_62_1_2004,39 +correctional_facilities_booking_waiting_ventilation,level_3_ventilation_62_1_2004,4 +correctional_facilities_day_room_ventilation,level_3_ventilation_62_1_2004,2 +correctional_facilities_guard_stations_ventilation,level_3_ventilation_62_1_2004,3 +educational_facilities_art_classroom_ventilation,level_3_ventilation_62_1_2004,10 +educational_facilities_classrooms_ages_5-8_ventilation,level_3_ventilation_62_1_2004,6 +educational_facilities_daycare_through_age_4_ventilation,level_3_ventilation_62_1_2004,5 +educational_facilities_lecture_classroom_ventilation,level_3_ventilation_62_1_2004,8 +educational_facilities_lecture_hall_fixed_seats_ventilation,level_3_ventilation_62_1_2004,9 +educational_facilities_media_center_ventilation,level_3_ventilation_62_1_2004,14 +educational_facilities_multi-use_assembly_ventilation,level_3_ventilation_62_1_2004,16 +educational_facilities_music_theater_dance_ventilation,level_3_ventilation_62_1_2004,15 +educational_facilities_science_laboratories_ventilation,level_3_ventilation_62_1_2004,11 +educational_facilities_wood_metal_shop_ventilation,level_3_ventilation_62_1_2004,12 +food_and_beverage_service_bars_cocktail_lounges_ventilation,level_3_ventilation_62_1_2004,19 +food_and_beverage_service_cafeteria_fast_food_dining_ventilation,level_3_ventilation_62_1_2004,18 +hotels_motels_resorts_dormitories_lobbies_prefunction_ventilation,level_3_ventilation_62_1_2004,25 +miscellaneous_spaces_bank_vaults_safe_deposit_ventilation,level_3_ventilation_62_1_2004,31 +miscellaneous_spaces_computer_not_printing_ventilation,level_3_ventilation_62_1_2004,32 +miscellaneous_spaces_photo_studios_ventilation,level_3_ventilation_62_1_2004,34 +miscellaneous_spaces_warehouses_ventilation,level_3_ventilation_62_1_2004,37 +public_assembly_spaces_lobbies_ventilation,level_3_ventilation_62_1_2004,43 +public_assembly_spaces_museums_childrens_ventilation,level_3_ventilation_62_1_2004,44 +retail_barber_shop_ventilation,level_3_ventilation_62_1_2004,48 +retail_beauty_and_nail_salons_ventilation,level_3_ventilation_62_1_2004,49 +retail_coin-operated_laundries_ventilation,level_3_ventilation_62_1_2004,52 +retail_pet_shops_animal_areas_ventilation,level_3_ventilation_62_1_2004,50 +retail_supermarket_ventilation,level_3_ventilation_62_1_2004,51 +sports_and_entertainment_bowling_alley_seating_ventilation,level_3_ventilation_62_1_2004,60 +sports_and_entertainment_disco_dance_floors_ventilation,level_3_ventilation_62_1_2004,57 +sports_and_entertainment_gambling_casinos_ventilation,level_3_ventilation_62_1_2004,61 +sports_and_entertainment_game_arcades_ventilation,level_3_ventilation_62_1_2004,62 +sports_and_entertainment_health_club_weight_rooms_ventilation,level_3_ventilation_62_1_2004,59 +sports_and_entertainment_spectator_areas_ventilation,level_3_ventilation_62_1_2004,55 +sports_and_entertainment_stages_studios_ventilation,level_3_ventilation_62_1_2004,63 +sports_and_entertainment_swimming_pool_deck_ventilation,level_3_ventilation_62_1_2004,56 +emergency_room_ventilation,level_3_ventilation_62_1_1999,83 +emergency_vehicle_garage_ventilation,level_3_ventilation_62_1_1999,83 +exam_treatment_ventilation,level_3_ventilation_62_1_1999,83 +imaging_ventilation,level_3_ventilation_62_1_1999,83 +interior_parking_ventilation,level_3_ventilation_62_1_1999,83 +food_preparation_ventilation,level_3_ventilation_62_1_1999,83 +laundry_washing_ventilation,level_3_ventilation_62_1_1999,83 +locker_room_ventilation,level_3_ventilation_62_1_1999,83 +lounge_breakroom_ventilation,level_3_ventilation_62_1_1999,83 +nursery_ventilation,level_3_ventilation_62_1_1999,83 +operating_room_ventilation,level_3_ventilation_62_1_1999,83 +patient_room_ventilation,level_3_ventilation_62_1_1999,83 +physical_therapy_ventilation,level_3_ventilation_62_1_1999,83 +recovery_ventilation,level_3_ventilation_62_1_1999,83 +restroom_ventilation,level_3_ventilation_62_1_1999,83 +vehicular_maintenance_ventilation,level_3_ventilation_62_1_1999,83 diff --git a/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.json b/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.json index 689b70d05b..fe249d1293 100644 --- a/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.json +++ b/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.json @@ -1,867 +1,2627 @@ [ { - "ventilation_space_type_name": "correctional_facilities_cell", + "ventilation_space_type_name": "airport_concourse_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 13 + "level_3_ventilation_definition_id": 63 }, { - "ventilation_space_type_name": "correctional_facilities_dayroom", + "ventilation_space_type_name": "atrium_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 14 + "level_3_ventilation_definition_id": 60 }, { - "ventilation_space_type_name": "correctional_facilities_guard_stations", + "ventilation_space_type_name": "attic_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 15 + "level_3_ventilation_definition_id": 110 }, { - "ventilation_space_type_name": "correctional_facilities_booking_waiting", + "ventilation_space_type_name": "audience_seating_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 12 + "level_3_ventilation_definition_id": 83 }, { - "ventilation_space_type_name": "educational_facilities_daycare", + "ventilation_space_type_name": "baggage_carousel_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 21 + "level_3_ventilation_definition_id": 63 }, { - "ventilation_space_type_name": "educational_facilities_classroom_young", + "ventilation_space_type_name": "banking_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 17 + "level_3_ventilation_definition_id": 46 }, { - "ventilation_space_type_name": "educational_facilities_classroom_old", + "ventilation_space_type_name": "classroom_lecture_training_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 18 }, { - "ventilation_space_type_name": "educational_facilities_lecture_classroom", + "ventilation_space_type_name": "computer_room_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 22 + "level_3_ventilation_definition_id": 19 }, { - "ventilation_space_type_name": "educational_facilities_lecture_hall", + "ventilation_space_type_name": "conference_meeting_multipurpose_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 23 + "level_3_ventilation_definition_id": 37 }, { - "ventilation_space_type_name": "educational_facilities_art_classroom", + "ventilation_space_type_name": "confinement_cells_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 16 + "level_3_ventilation_definition_id": 13 }, { - "ventilation_space_type_name": "educational_facilities_science_laboratories", + "ventilation_space_type_name": "copy_print_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 28 + "level_3_ventilation_definition_id": 64 }, { - "ventilation_space_type_name": "educational_facilities_wood_metal_shop", + "ventilation_space_type_name": "corridor_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 30 + "level_3_ventilation_definition_id": 38 }, { - "ventilation_space_type_name": "educational_facilities_computer_lab", + "ventilation_space_type_name": "courtroom_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 19 + "level_3_ventilation_definition_id": 84 }, { - "ventilation_space_type_name": "educational_facilities_media_center", + "ventilation_space_type_name": "datacenterhighite_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 25 + "level_3_ventilation_definition_id": 110 }, { - "ventilation_space_type_name": "educational_facilities_music_theater_dance", + "ventilation_space_type_name": "datacenterlowite_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 27 + "level_3_ventilation_definition_id": 110 }, { - "ventilation_space_type_name": "educational_facilities_multiuse_assembly", + "ventilation_space_type_name": "dining_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 26 + "level_3_ventilation_definition_id": 34 }, { - "ventilation_space_type_name": "educational_facilities_daycare_sickroom", + "ventilation_space_type_name": "dressing_room_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 20 + "level_3_ventilation_definition_id": 95 }, { - "ventilation_space_type_name": "educational_facilities_libraries", + "ventilation_space_type_name": "electrical_mechanical_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 24 + "level_3_ventilation_definition_id": 110 }, { - "ventilation_space_type_name": "educational_facilities_university_college_laboratories", + "ventilation_space_type_name": "emergency_room_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 29 + "level_3_ventilation_definition_id": 79 }, { - "ventilation_space_type_name": "food_beverage_service_restaurant_dining_rooms", + "ventilation_space_type_name": "exam_treatment_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 34 + "level_3_ventilation_definition_id": 68 }, { - "ventilation_space_type_name": "food_beverage_service_cafeteria_fast_food_dining", + "ventilation_space_type_name": "exercise_area_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 32 + "level_3_ventilation_definition_id": 103 }, { - "ventilation_space_type_name": "food_beverage_service_bars_cocktail_lounges", + "ventilation_space_type_name": "exhibit_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 31 + "level_3_ventilation_definition_id": 89 }, { - "ventilation_space_type_name": "food_beverage_service_kitchen", + "ventilation_space_type_name": "guest_room_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 33 + "level_3_ventilation_definition_id": 41 }, { - "ventilation_space_type_name": "general_conference_meeting", + "ventilation_space_type_name": "imaging_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 37 + "level_3_ventilation_definition_id": 66 }, { - "ventilation_space_type_name": "general_conference_corridors", + "ventilation_space_type_name": "judges_chambers_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 38 + "level_3_ventilation_definition_id": 85 }, { - "ventilation_space_type_name": "general_conference_storage_rooms", + "ventilation_space_type_name": "food_preparation_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 39 + "level_3_ventilation_definition_id": 33 }, { - "ventilation_space_type_name": "general_break_rooms", + "ventilation_space_type_name": "laboratory_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 35 + "level_3_ventilation_definition_id": 28 }, { - "ventilation_space_type_name": "general_coffee_stations", + "ventilation_space_type_name": "laundry_washing_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 36 + "level_3_ventilation_definition_id": 42 }, { - "ventilation_space_type_name": "hotels_motels_resorts_dormitories_bedroom_living_room", + "ventilation_space_type_name": "library_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 41 + "level_3_ventilation_definition_id": 86 }, { - "ventilation_space_type_name": "hotels_motels_resorts_dormitories_barracks_sleeping_areas", + "ventilation_space_type_name": "living_quarters_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", "level_3_ventilation_definition_id": 40 }, { - "ventilation_space_type_name": "hotels_motels_resorts_dormitories_lobbies_prefunction", + "ventilation_space_type_name": "loading_dock_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 44 + "level_3_ventilation_definition_id": 54 }, { - "ventilation_space_type_name": "hotels_motels_resorts_dormitories_multi_purpose_assembly", + "ventilation_space_type_name": "lobby_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 45 + "level_3_ventilation_definition_id": 60 }, { - "ventilation_space_type_name": "hotels_motels_resorts_dormitories_laundry_rooms", + "ventilation_space_type_name": "locker_room_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 42 + "level_3_ventilation_definition_id": 35 }, { - "ventilation_space_type_name": "hotels_motels_resorts_dormitories_laundry_rooms_w_dwelling_units", + "ventilation_space_type_name": "lounge_breakroom_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 43 + "level_3_ventilation_definition_id": 35 }, { - "ventilation_space_type_name": "office_buildings_office_space", + "ventilation_space_type_name": "manufacturing_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 62 + "level_3_ventilation_definition_id": 50 }, { - "ventilation_space_type_name": "office_buildings_reception_areas", + "ventilation_space_type_name": "medical_supply_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 63 + "level_3_ventilation_definition_id": 52 }, { - "ventilation_space_type_name": "office_buildings_telephone_data_entry", + "ventilation_space_type_name": "multifamily_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 64 + "level_3_ventilation_definition_id": 41 }, { - "ventilation_space_type_name": "office_buildings_main_entry_lobbies", + "ventilation_space_type_name": "nursery_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 60 + "level_3_ventilation_definition_id": 65 }, { - "ventilation_space_type_name": "office_buildings_breakrooms", + "ventilation_space_type_name": "nurses_station_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 59 + "level_3_ventilation_definition_id": 63 }, { - "ventilation_space_type_name": "office_buildings_occupiable_storage_rooms", + "ventilation_space_type_name": "office_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 61 + "level_3_ventilation_definition_id": 62 }, { - "ventilation_space_type_name": "miscellaneous_spaces_bank_ vaults_safe_deposit", + "ventilation_space_type_name": "office_enclosed_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 47 + "level_3_ventilation_definition_id": 62 }, { - "ventilation_space_type_name": "miscellaneous_spaces_computer", + "ventilation_space_type_name": "operating_room_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 48 + "level_3_ventilation_definition_id": 81 }, { - "ventilation_space_type_name": "miscellaneous_spaces_pharmacy", + "ventilation_space_type_name": "patient_room_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 52 + "level_3_ventilation_definition_id": 80 }, { - "ventilation_space_type_name": "miscellaneous_spaces_photo_studios", + "ventilation_space_type_name": "pharmacy_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 53 + "level_3_ventilation_definition_id": 52 }, { - "ventilation_space_type_name": "miscellaneous_spaces_shipping_receiving", + "ventilation_space_type_name": "physical_therapy_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 54 + "level_3_ventilation_definition_id": 70 }, { - "ventilation_space_type_name": "miscellaneous_spaces_transportation_waiting", + "ventilation_space_type_name": "playing_area_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 57 + "level_3_ventilation_definition_id": 102 }, { - "ventilation_space_type_name": "miscellaneous_spaces_warehouses", + "ventilation_space_type_name": "plenum_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 58 + "level_3_ventilation_definition_id": 110 }, { - "ventilation_space_type_name": "miscellaneous_spaces_banks_bank_lobbies", + "ventilation_space_type_name": "post_office_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 46 + "level_3_ventilation_definition_id": 54 }, { - "ventilation_space_type_name": "miscellaneous_spaces_freezer_refrigerated_spaces", + "ventilation_space_type_name": "recovery_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 49 + "level_3_ventilation_definition_id": 80 }, { - "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_wo_hazardous_materials", + "ventilation_space_type_name": "recreation_common_living_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 50 + "level_3_ventilation_definition_id": 45 }, { - "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_w_hazardous_materials", + "ventilation_space_type_name": "retail_sales_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 51 + "level_3_ventilation_definition_id": 91 }, { - "ventilation_space_type_name": "miscellaneous_spaces_sorting_packing_light_assembly", + "ventilation_space_type_name": "shaft_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 55 + "level_3_ventilation_definition_id": 110 }, { - "ventilation_space_type_name": "miscellaneous_spaces_telephone_closets", + "ventilation_space_type_name": "sleeping_quarters_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 56 + "level_3_ventilation_definition_id": 40 }, { - "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", + "ventilation_space_type_name": "sports_arena_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 83 + "level_3_ventilation_definition_id": 102 }, { - "ventilation_space_type_name": "public_assembly_spaces_religious_workshop", + "ventilation_space_type_name": "stairwell_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 90 + "level_3_ventilation_definition_id": 110 }, { - "ventilation_space_type_name": "public_assembly_spaces_courtrooms", + "ventilation_space_type_name": "storage_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 84 + "level_3_ventilation_definition_id": 61 }, { - "ventilation_space_type_name": "public_assembly_spaces_legislative_chambers", + "ventilation_space_type_name": "transportation_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 85 + "level_3_ventilation_definition_id": 57 }, { - "ventilation_space_type_name": "public_assembly_spaces_libraries", + "ventilation_space_type_name": "workshop_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 86 + "level_3_ventilation_definition_id": 50 }, { - "ventilation_space_type_name": "public_assembly_spaces_lobbies", + "ventilation_space_type_name": "worship_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 87 + "level_3_ventilation_definition_id": 90 }, { - "ventilation_space_type_name": "public_assembly_spaces_children_museums", + "ventilation_space_type_name": "correctional_facilities_booking_waiting_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 88 + "level_3_ventilation_definition_id": 12 }, { - "ventilation_space_type_name": "public_assembly_spaces_museums_galleries", + "ventilation_space_type_name": "correctional_facilities_day_room_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 89 + "level_3_ventilation_definition_id": 14 }, { - "ventilation_space_type_name": "retail_sales", + "ventilation_space_type_name": "correctional_facilities_guard_stations_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 91 + "level_3_ventilation_definition_id": 15 }, { - "ventilation_space_type_name": "retail_mall_common_areas", + "ventilation_space_type_name": "educational_facilities_art_classroom_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 95 + "level_3_ventilation_definition_id": 16 }, { - "ventilation_space_type_name": "retail_barbershop", + "ventilation_space_type_name": "educational_facilities_classrooms_ages_5-8_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 92 + "level_3_ventilation_definition_id": 17 }, { - "ventilation_space_type_name": "retail_beauty_nail_salons", + "ventilation_space_type_name": "educational_facilities_daycare_through_age_4_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 93 + "level_3_ventilation_definition_id": 21 }, { - "ventilation_space_type_name": "retail_pet_shops", + "ventilation_space_type_name": "educational_facilities_lecture_classroom_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 96 + "level_3_ventilation_definition_id": 22 }, { - "ventilation_space_type_name": "retail_supermarket", + "ventilation_space_type_name": "educational_facilities_lecture_hall_fixed_seats_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 97 + "level_3_ventilation_definition_id": 23 }, { - "ventilation_space_type_name": "retail_coin_operated_laundries", + "ventilation_space_type_name": "educational_facilities_media_center_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 94 + "level_3_ventilation_definition_id": 25 }, { - "ventilation_space_type_name": "sports_entertainment_sports_arena", + "ventilation_space_type_name": "educational_facilities_multi-use_assembly_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 102 + "level_3_ventilation_definition_id": 26 }, { - "ventilation_space_type_name": "sports_entertainment_gym_stadium", + "ventilation_space_type_name": "educational_facilities_music_theater_dance_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 102 + "level_3_ventilation_definition_id": 27 }, { - "ventilation_space_type_name": "sports_entertainment_spectator_areas", + "ventilation_space_type_name": "educational_facilities_science_laboratories_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 105 + "level_3_ventilation_definition_id": 29 }, { - "ventilation_space_type_name": "sports_entertainment_swimming", + "ventilation_space_type_name": "educational_facilities_wood_metal_shop_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 107 + "level_3_ventilation_definition_id": 30 }, { - "ventilation_space_type_name": "sports_entertainment_disco_dance_floors", + "ventilation_space_type_name": "food_and_beverage_service_bars_cocktail_lounges_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 99 + "level_3_ventilation_definition_id": 31 }, { - "ventilation_space_type_name": "sports_entertainment_health_club_aerobics_room", + "ventilation_space_type_name": "food_and_beverage_service_cafeteria_fast_food_dining_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 103 + "level_3_ventilation_definition_id": 32 }, { - "ventilation_space_type_name": "sports_entertainment_health_club_weight_rooms", + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_lobbies_prefunction_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 104 + "level_3_ventilation_definition_id": 44 }, { - "ventilation_space_type_name": "sports_entertainment_bowling_alley", + "ventilation_space_type_name": "miscellaneous_spaces_bank_vaults_safe_deposit_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 98 + "level_3_ventilation_definition_id": 47 }, { - "ventilation_space_type_name": "sports_entertainment_gambling_casinos", + "ventilation_space_type_name": "miscellaneous_spaces_computer_not_printing_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 100 + "level_3_ventilation_definition_id": 48 }, { - "ventilation_space_type_name": "sports_entertainment_game_arcades", + "ventilation_space_type_name": "miscellaneous_spaces_photo_studios_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 101 + "level_3_ventilation_definition_id": 53 }, { - "ventilation_space_type_name": "sports_entertainment_stages_studios", + "ventilation_space_type_name": "miscellaneous_spaces_warehouses_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 106 + "level_3_ventilation_definition_id": 58 }, { - "ventilation_space_type_name": "animal_facilities_animal_exam_room", + "ventilation_space_type_name": "public_assembly_spaces_lobbies_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 1 + "level_3_ventilation_definition_id": 87 }, { - "ventilation_space_type_name": "animal_facilities_animal_imaging", + "ventilation_space_type_name": "public_assembly_spaces_museums_childrens_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 2 + "level_3_ventilation_definition_id": 88 }, { - "ventilation_space_type_name": "animal_facilities_animal_operating_rooms", + "ventilation_space_type_name": "retail_barber_shop_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 3 + "level_3_ventilation_definition_id": 92 }, { - "ventilation_space_type_name": "animal_facilities_animal_postoperative_recovery_room", + "ventilation_space_type_name": "retail_beauty_and_nail_salons_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 4 + "level_3_ventilation_definition_id": 93 }, { - "ventilation_space_type_name": "animal_facilities_animal_preparation_rooms", + "ventilation_space_type_name": "retail_coin-operated_laundries_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 5 + "level_3_ventilation_definition_id": 94 }, { - "ventilation_space_type_name": "animal_facilities_animal_procedure_room", + "ventilation_space_type_name": "retail_pet_shops_animal_areas_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 6 + "level_3_ventilation_definition_id": 96 }, { - "ventilation_space_type_name": "animal_facilities_animal_surgery_scrub", + "ventilation_space_type_name": "retail_supermarket_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 7 + "level_3_ventilation_definition_id": 97 }, { - "ventilation_space_type_name": "animal_facilities_large_animal_holding_room", + "ventilation_space_type_name": "sports_and_entertainment_bowling_alley_seating_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 8 + "level_3_ventilation_definition_id": 98 }, { - "ventilation_space_type_name": "animal_facilities_necropsy", + "ventilation_space_type_name": "sports_and_entertainment_disco_dance_floors_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 9 + "level_3_ventilation_definition_id": 99 }, { - "ventilation_space_type_name": "animal_facilities_small_animal_cage_room_static", + "ventilation_space_type_name": "sports_and_entertainment_gambling_casinos_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 10 + "level_3_ventilation_definition_id": 100 }, { - "ventilation_space_type_name": "animal_facilities_small_animal_cage_room_ventilated", + "ventilation_space_type_name": "sports_and_entertainment_game_arcades_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 11 + "level_3_ventilation_definition_id": 101 }, { - "ventilation_space_type_name": "outpatient_health_care_facilities_birthing_room", + "ventilation_space_type_name": "sports_and_entertainment_health_club_weight_rooms_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 65 + "level_3_ventilation_definition_id": 104 }, { - "ventilation_space_type_name": "outpatient_health_care_facilities_class_1_imaging_rooms", + "ventilation_space_type_name": "sports_and_entertainment_spectator_areas_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 66 + "level_3_ventilation_definition_id": 105 }, { - "ventilation_space_type_name": "outpatient_health_care_facilities_dental_operatory", + "ventilation_space_type_name": "sports_and_entertainment_stages_studios_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 67 + "level_3_ventilation_definition_id": 106 }, { - "ventilation_space_type_name": "outpatient_health_care_facilities_general_examination_room", + "ventilation_space_type_name": "sports_and_entertainment_swimming_pool_deck_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 68 + "level_3_ventilation_definition_id": 107 }, { - "ventilation_space_type_name": "outpatient_health_care_facilities_other_dental_treatment_areas", - "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 69 + "ventilation_space_type_name": "airport_concourse_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 50 }, { - "ventilation_space_type_name": "outpatient_health_care_facilities_physical_therapy_exercise_area", - "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 70 + "ventilation_space_type_name": "atrium_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 47 }, { - "ventilation_space_type_name": "outpatient_health_care_facilities_physical_therapy_individual_room", - "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 71 + "ventilation_space_type_name": "attic_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 79 }, { - "ventilation_space_type_name": "outpatient_health_care_facilities_physical_therapeutic_pool_area", - "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 72 + "ventilation_space_type_name": "audience_seating_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 52 }, { - "ventilation_space_type_name": "outpatient_health_care_facilities_prosthetics_orthotics_room", - "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 73 + "ventilation_space_type_name": "baggage_carousel_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 50 }, { - "ventilation_space_type_name": "outpatient_health_care_facilities_psychiatric_consultation_room", - "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 74 + "ventilation_space_type_name": "banking_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 35 }, { - "ventilation_space_type_name": "outpatient_health_care_facilities_psychiatric_examination_room", - "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 75 + "ventilation_space_type_name": "classroom_lecture_training_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 8 }, { - "ventilation_space_type_name": "outpatient_health_care_facilities_psychiatric_group_room", - "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 76 + "ventilation_space_type_name": "computer_room_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 15 }, { - "ventilation_space_type_name": "outpatient_health_care_facilities_psychiatric_seclusion_room", - "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 77 + "ventilation_space_type_name": "conference_meeting_multipurpose_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 25 }, { - "ventilation_space_type_name": "outpatient_health_care_facilities_speech_therapy_room", - "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 78 + "ventilation_space_type_name": "confinement_cells_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 1 }, { - "ventilation_space_type_name": "outpatient_health_care_facilities_urgent_care_examination_room", - "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 79 + "ventilation_space_type_name": "copy_print_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 51 }, { - "ventilation_space_type_name": "outpatient_health_care_facilities_urgent_care_observation_room", - "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 80 + "ventilation_space_type_name": "corridor_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 26 }, { - "ventilation_space_type_name": "outpatient_health_care_facilities_urgent_care_treatment_room", - "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 81 + "ventilation_space_type_name": "courtroom_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 54 }, { - "ventilation_space_type_name": "outpatient_health_care_facilities_urgent_care_triage_room", - "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 82 + "ventilation_space_type_name": "datacenterhighite_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 79 }, { - "ventilation_space_type_name": "transient_residential_common_corridors", - "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 108 + "ventilation_space_type_name": "datacenterlowite_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 79 }, { - "ventilation_space_type_name": "transient_residential_dwelling_unit", - "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2019", - "level_3_ventilation_definition_id": 109 + "ventilation_space_type_name": "dining_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 19 }, { - "ventilation_space_type_name": "correctional_facilities_cell", - "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 1 + "ventilation_space_type_name": "dressing_room_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 63 }, { - "ventilation_space_type_name": "correctional_facilities_dayroom", - "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 2 + "ventilation_space_type_name": "electrical_mechanical_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 79 }, { - "ventilation_space_type_name": "correctional_facilities_guard_stations", - "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 3 + "ventilation_space_type_name": "exercise_area_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 73 }, { - "ventilation_space_type_name": "correctional_facilities_booking_waiting", - "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 4 + "ventilation_space_type_name": "exhibit_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 59 }, { - "ventilation_space_type_name": "educational_facilities_daycare", - "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 5 + "ventilation_space_type_name": "guest_room_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 28 }, { - "ventilation_space_type_name": "educational_facilities_classroom_young", - "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 6 + "ventilation_space_type_name": "judges_chambers_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 55 }, { - "ventilation_space_type_name": "educational_facilities_classroom_old", - "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 7 + "ventilation_space_type_name": "food_preparation_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 22 }, { - "ventilation_space_type_name": "educational_facilities_lecture_classroom", - "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 8 + "ventilation_space_type_name": "laboratory_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 12 }, { - "ventilation_space_type_name": "educational_facilities_lecture_hall", - "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 9 + "ventilation_space_type_name": "laundry_washing_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 30 }, { - "ventilation_space_type_name": "educational_facilities_art_classroom", - "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 10 + "ventilation_space_type_name": "library_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 56 }, { - "ventilation_space_type_name": "educational_facilities_science_laboratories", - "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 11 + "ventilation_space_type_name": "living_quarters_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 29 }, { - "ventilation_space_type_name": "educational_facilities_wood_metal_shop", - "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "ventilation_space_type_name": "loading_dock_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 41 + }, + { + "ventilation_space_type_name": "lobby_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 47 + }, + { + "ventilation_space_type_name": "locker_room_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 23 + }, + { + "ventilation_space_type_name": "lounge_breakroom_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 23 + }, + { + "ventilation_space_type_name": "medical_supply_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 39 + }, + { + "ventilation_space_type_name": "multifamily_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 28 + }, + { + "ventilation_space_type_name": "nurses_station_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 50 + }, + { + "ventilation_space_type_name": "office_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 49 + }, + { + "ventilation_space_type_name": "office_enclosed_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 49 + }, + { + "ventilation_space_type_name": "pharmacy_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 39 + }, + { + "ventilation_space_type_name": "playing_area_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 69 + }, + { + "ventilation_space_type_name": "plenum_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 79 + }, + { + "ventilation_space_type_name": "post_office_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 41 + }, + { + "ventilation_space_type_name": "recreation_common_living_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 33 + }, + { + "ventilation_space_type_name": "retail_sales_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 62 + }, + { + "ventilation_space_type_name": "shaft_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 79 + }, + { + "ventilation_space_type_name": "sleeping_quarters_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 29 + }, + { + "ventilation_space_type_name": "sports_arena_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 69 + }, + { + "ventilation_space_type_name": "stairwell_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 79 + }, + { + "ventilation_space_type_name": "storage_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 48 + }, + { + "ventilation_space_type_name": "transportation_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 44 + }, + { + "ventilation_space_type_name": "worship_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 53 + }, + { + "ventilation_space_type_name": "correctional_facilities_booking_waiting_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 4 + }, + { + "ventilation_space_type_name": "correctional_facilities_day_room_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 2 + }, + { + "ventilation_space_type_name": "correctional_facilities_guard_stations_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 3 + }, + { + "ventilation_space_type_name": "educational_facilities_art_classroom_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 11 + }, + { + "ventilation_space_type_name": "educational_facilities_classrooms_ages_5-8_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 7 + }, + { + "ventilation_space_type_name": "educational_facilities_daycare_through_age_4_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 5 + }, + { + "ventilation_space_type_name": "educational_facilities_lecture_classroom_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 9 + }, + { + "ventilation_space_type_name": "educational_facilities_lecture_hall_fixed_seats_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 10 + }, + { + "ventilation_space_type_name": "educational_facilities_media_center_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 16 + }, + { + "ventilation_space_type_name": "educational_facilities_multi-use_assembly_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 18 + }, + { + "ventilation_space_type_name": "educational_facilities_music_theater_dance_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 17 + }, + { + "ventilation_space_type_name": "educational_facilities_science_laboratories_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 13 + }, + { + "ventilation_space_type_name": "educational_facilities_wood_metal_shop_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 14 + }, + { + "ventilation_space_type_name": "food_and_beverage_service_bars_cocktail_lounges_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 21 + }, + { + "ventilation_space_type_name": "food_and_beverage_service_cafeteria_fast_food_dining_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 20 + }, + { + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_lobbies_prefunction_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 32 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_bank_vaults_safe_deposit_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 34 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_computer_not_printing_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 36 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_photo_studios_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 40 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_warehouses_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 45 + }, + { + "ventilation_space_type_name": "public_assembly_spaces_lobbies_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 57 + }, + { + "ventilation_space_type_name": "public_assembly_spaces_museums_childrens_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 58 + }, + { + "ventilation_space_type_name": "retail_barber_shop_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 64 + }, + { + "ventilation_space_type_name": "retail_beauty_and_nail_salons_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 65 + }, + { + "ventilation_space_type_name": "retail_coin-operated_laundries_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 68 + }, + { + "ventilation_space_type_name": "retail_pet_shops_animal_areas_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 66 + }, + { + "ventilation_space_type_name": "retail_supermarket_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 67 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_bowling_alley_seating_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 75 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_disco_dance_floors_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 72 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_gambling_casinos_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 76 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_game_arcades_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 77 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_health_club_weight_rooms_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 74 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_spectator_areas_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 70 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_stages_studios_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 78 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_swimming_pool_deck_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2016", + "level_3_ventilation_definition_id": 71 + }, + { + "ventilation_space_type_name": "airport_concourse_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 50 + }, + { + "ventilation_space_type_name": "atrium_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 47 + }, + { + "ventilation_space_type_name": "attic_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 79 + }, + { + "ventilation_space_type_name": "audience_seating_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 52 + }, + { + "ventilation_space_type_name": "baggage_carousel_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 50 + }, + { + "ventilation_space_type_name": "banking_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 35 + }, + { + "ventilation_space_type_name": "classroom_lecture_training_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 8 + }, + { + "ventilation_space_type_name": "computer_room_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 15 + }, + { + "ventilation_space_type_name": "conference_meeting_multipurpose_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 25 + }, + { + "ventilation_space_type_name": "confinement_cells_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 1 + }, + { + "ventilation_space_type_name": "copy_print_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 51 + }, + { + "ventilation_space_type_name": "corridor_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 26 + }, + { + "ventilation_space_type_name": "courtroom_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 54 + }, + { + "ventilation_space_type_name": "datacenterhighite_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 79 + }, + { + "ventilation_space_type_name": "datacenterlowite_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 79 + }, + { + "ventilation_space_type_name": "dining_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 19 + }, + { + "ventilation_space_type_name": "dressing_room_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 63 + }, + { + "ventilation_space_type_name": "electrical_mechanical_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 79 + }, + { + "ventilation_space_type_name": "exercise_area_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 73 + }, + { + "ventilation_space_type_name": "exhibit_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 59 + }, + { + "ventilation_space_type_name": "guest_room_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 28 + }, + { + "ventilation_space_type_name": "judges_chambers_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 55 + }, + { + "ventilation_space_type_name": "food_preparation_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 22 + }, + { + "ventilation_space_type_name": "laboratory_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 12 + }, + { + "ventilation_space_type_name": "laundry_washing_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 30 + }, + { + "ventilation_space_type_name": "library_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 56 + }, + { + "ventilation_space_type_name": "living_quarters_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 29 + }, + { + "ventilation_space_type_name": "loading_dock_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 41 + }, + { + "ventilation_space_type_name": "lobby_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 47 + }, + { + "ventilation_space_type_name": "locker_room_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 23 + }, + { + "ventilation_space_type_name": "lounge_breakroom_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 23 + }, + { + "ventilation_space_type_name": "medical_supply_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 39 + }, + { + "ventilation_space_type_name": "multifamily_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 28 + }, + { + "ventilation_space_type_name": "nurses_station_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 50 + }, + { + "ventilation_space_type_name": "office_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 49 + }, + { + "ventilation_space_type_name": "office_enclosed_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 49 + }, + { + "ventilation_space_type_name": "pharmacy_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 39 + }, + { + "ventilation_space_type_name": "playing_area_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 69 + }, + { + "ventilation_space_type_name": "plenum_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 79 + }, + { + "ventilation_space_type_name": "post_office_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 41 + }, + { + "ventilation_space_type_name": "recreation_common_living_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 33 + }, + { + "ventilation_space_type_name": "retail_sales_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 62 + }, + { + "ventilation_space_type_name": "shaft_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 79 + }, + { + "ventilation_space_type_name": "sleeping_quarters_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 29 + }, + { + "ventilation_space_type_name": "sports_arena_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 69 + }, + { + "ventilation_space_type_name": "stairwell_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 79 + }, + { + "ventilation_space_type_name": "storage_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 48 + }, + { + "ventilation_space_type_name": "transportation_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 44 + }, + { + "ventilation_space_type_name": "worship_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 53 + }, + { + "ventilation_space_type_name": "correctional_facilities_booking_waiting_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 4 + }, + { + "ventilation_space_type_name": "correctional_facilities_day_room_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 2 + }, + { + "ventilation_space_type_name": "correctional_facilities_guard_stations_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 3 + }, + { + "ventilation_space_type_name": "educational_facilities_art_classroom_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 11 + }, + { + "ventilation_space_type_name": "educational_facilities_classrooms_ages_5-8_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 7 + }, + { + "ventilation_space_type_name": "educational_facilities_daycare_through_age_4_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 5 + }, + { + "ventilation_space_type_name": "educational_facilities_lecture_classroom_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 9 + }, + { + "ventilation_space_type_name": "educational_facilities_lecture_hall_fixed_seats_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 10 + }, + { + "ventilation_space_type_name": "educational_facilities_media_center_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 16 + }, + { + "ventilation_space_type_name": "educational_facilities_multi-use_assembly_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 18 + }, + { + "ventilation_space_type_name": "educational_facilities_music_theater_dance_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 17 + }, + { + "ventilation_space_type_name": "educational_facilities_science_laboratories_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 12 + }, + { + "ventilation_space_type_name": "educational_facilities_wood_metal_shop_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 14 + }, + { + "ventilation_space_type_name": "food_and_beverage_service_bars_cocktail_lounges_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 21 + }, + { + "ventilation_space_type_name": "food_and_beverage_service_cafeteria_fast_food_dining_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 20 + }, + { + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_lobbies_prefunction_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 32 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_bank_vaults_safe_deposit_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 34 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_computer_not_printing_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 36 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_photo_studios_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 40 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_warehouses_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 45 + }, + { + "ventilation_space_type_name": "public_assembly_spaces_lobbies_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 57 + }, + { + "ventilation_space_type_name": "public_assembly_spaces_museums_childrens_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 58 + }, + { + "ventilation_space_type_name": "retail_barber_shop_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 64 + }, + { + "ventilation_space_type_name": "retail_beauty_and_nail_salons_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 65 + }, + { + "ventilation_space_type_name": "retail_coin-operated_laundries_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 68 + }, + { + "ventilation_space_type_name": "retail_pet_shops_animal_areas_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 66 + }, + { + "ventilation_space_type_name": "retail_supermarket_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 67 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_bowling_alley_seating_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 75 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_disco_dance_floors_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 72 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_gambling_casinos_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 76 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_game_arcades_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 77 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_health_club_weight_rooms_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 74 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_spectator_areas_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 70 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_stages_studios_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 78 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_swimming_pool_deck_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2013", + "level_3_ventilation_definition_id": 71 + }, + { + "ventilation_space_type_name": "airport_concourse_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 38 + }, + { + "ventilation_space_type_name": "atrium_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 35 + }, + { + "ventilation_space_type_name": "attic_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 79 + }, + { + "ventilation_space_type_name": "audience_seating_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 51 + }, + { + "ventilation_space_type_name": "baggage_carousel_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 38 + }, + { + "ventilation_space_type_name": "banking_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 41 + }, + { + "ventilation_space_type_name": "classroom_lecture_training_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 8 + }, + { + "ventilation_space_type_name": "computer_room_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 15 + }, + { + "ventilation_space_type_name": "conference_meeting_multipurpose_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 25 + }, + { + "ventilation_space_type_name": "confinement_cells_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 1 + }, + { + "ventilation_space_type_name": "copy_print_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 39 + }, + { + "ventilation_space_type_name": "corridor_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 26 + }, + { + "ventilation_space_type_name": "courtroom_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 53 + }, + { + "ventilation_space_type_name": "datacenterhighite_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 79 + }, + { + "ventilation_space_type_name": "datacenterlowite_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 79 + }, + { + "ventilation_space_type_name": "dining_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 19 + }, + { + "ventilation_space_type_name": "dressing_room_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 62 + }, + { + "ventilation_space_type_name": "electrical_mechanical_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 79 + }, + { + "ventilation_space_type_name": "exercise_area_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 73 + }, + { + "ventilation_space_type_name": "exhibit_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 58 + }, + { + "ventilation_space_type_name": "guest_room_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 28 + }, + { + "ventilation_space_type_name": "judges_chambers_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 54 + }, + { + "ventilation_space_type_name": "food_preparation_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 22 + }, + { + "ventilation_space_type_name": "laboratory_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 12 + }, + { + "ventilation_space_type_name": "laundry_washing_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 30 + }, + { + "ventilation_space_type_name": "library_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 55 + }, + { + "ventilation_space_type_name": "living_quarters_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 29 + }, + { + "ventilation_space_type_name": "loading_dock_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 46 + }, + { + "ventilation_space_type_name": "lobby_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 35 + }, + { + "ventilation_space_type_name": "locker_room_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 23 + }, + { + "ventilation_space_type_name": "lounge_breakroom_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 23 + }, + { + "ventilation_space_type_name": "medical_supply_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 44 + }, + { + "ventilation_space_type_name": "multifamily_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 28 + }, + { + "ventilation_space_type_name": "nurses_station_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 38 + }, + { + "ventilation_space_type_name": "office_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 37 + }, + { + "ventilation_space_type_name": "office_enclosed_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 37 + }, + { + "ventilation_space_type_name": "pharmacy_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 44 + }, + { + "ventilation_space_type_name": "playing_area_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 69 + }, + { + "ventilation_space_type_name": "plenum_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 79 + }, + { + "ventilation_space_type_name": "post_office_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 46 + }, + { + "ventilation_space_type_name": "recreation_common_living_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 33 + }, + { + "ventilation_space_type_name": "retail_sales_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 61 + }, + { + "ventilation_space_type_name": "shaft_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 79 + }, + { + "ventilation_space_type_name": "sleeping_quarters_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 29 + }, + { + "ventilation_space_type_name": "sports_arena_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 68 + }, + { + "ventilation_space_type_name": "stairwell_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 79 + }, + { + "ventilation_space_type_name": "storage_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 36 + }, + { + "ventilation_space_type_name": "transportation_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 49 + }, + { + "ventilation_space_type_name": "worship_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 52 + }, + { + "ventilation_space_type_name": "correctional_facilities_booking_waiting_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 4 + }, + { + "ventilation_space_type_name": "correctional_facilities_day_room_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 2 + }, + { + "ventilation_space_type_name": "correctional_facilities_guard_stations_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 3 + }, + { + "ventilation_space_type_name": "educational_facilities_art_classroom_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 11 + }, + { + "ventilation_space_type_name": "educational_facilities_classrooms_ages_5-8_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 7 + }, + { + "ventilation_space_type_name": "educational_facilities_daycare_through_age_4_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 5 + }, + { + "ventilation_space_type_name": "educational_facilities_lecture_classroom_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 9 + }, + { + "ventilation_space_type_name": "educational_facilities_lecture_hall_fixed_seats_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 10 + }, + { + "ventilation_space_type_name": "educational_facilities_media_center_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 16 + }, + { + "ventilation_space_type_name": "educational_facilities_multi-use_assembly_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 18 + }, + { + "ventilation_space_type_name": "educational_facilities_music_theater_dance_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 17 + }, + { + "ventilation_space_type_name": "educational_facilities_science_laboratories_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 12 + }, + { + "ventilation_space_type_name": "educational_facilities_wood_metal_shop_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 14 + }, + { + "ventilation_space_type_name": "food_and_beverage_service_bars_cocktail_lounges_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 21 + }, + { + "ventilation_space_type_name": "food_and_beverage_service_cafeteria_fast_food_dining_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 20 + }, + { + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_lobbies_prefunction_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 32 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_bank_vaults_safe_deposit_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 40 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_computer_not_printing_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 42 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_photo_studios_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 45 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_warehouses_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 50 + }, + { + "ventilation_space_type_name": "public_assembly_spaces_lobbies_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 56 + }, + { + "ventilation_space_type_name": "public_assembly_spaces_museums_childrens_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 57 + }, + { + "ventilation_space_type_name": "retail_barber_shop_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 63 + }, + { + "ventilation_space_type_name": "retail_beauty_and_nail_salons_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 64 + }, + { + "ventilation_space_type_name": "retail_coin-operated_laundries_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 67 + }, + { + "ventilation_space_type_name": "retail_pet_shops_animal_areas_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 65 + }, + { + "ventilation_space_type_name": "retail_supermarket_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 66 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_bowling_alley_seating_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 75 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_disco_dance_floors_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 72 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_gambling_casinos_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 76 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_game_arcades_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 77 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_health_club_weight_rooms_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 74 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_spectator_areas_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 70 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_stages_studios_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 78 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_swimming_pool_deck_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2010", + "level_3_ventilation_definition_id": 71 + }, + { + "ventilation_space_type_name": "airport_concourse_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 34 + }, + { + "ventilation_space_type_name": "atrium_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 36 + }, + { + "ventilation_space_type_name": "attic_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 75 + }, + { + "ventilation_space_type_name": "audience_seating_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 47 + }, + { + "ventilation_space_type_name": "baggage_carousel_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 34 + }, + { + "ventilation_space_type_name": "banking_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 34 + }, + { + "ventilation_space_type_name": "classroom_lecture_training_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 8 + }, + { + "ventilation_space_type_name": "computer_room_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 15 + }, + { + "ventilation_space_type_name": "conference_meeting_multipurpose_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 24 + }, + { + "ventilation_space_type_name": "confinement_cells_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 1 + }, + { + "ventilation_space_type_name": "copy_print_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 35 + }, + { + "ventilation_space_type_name": "corridor_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 25 + }, + { + "ventilation_space_type_name": "courtroom_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 49 + }, + { + "ventilation_space_type_name": "datacenterhighite_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 75 + }, + { + "ventilation_space_type_name": "datacenterlowite_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 75 + }, + { + "ventilation_space_type_name": "dining_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 19 + }, + { + "ventilation_space_type_name": "dressing_room_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 58 + }, + { + "ventilation_space_type_name": "electrical_mechanical_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 75 + }, + { + "ventilation_space_type_name": "exercise_area_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 69 + }, + { + "ventilation_space_type_name": "exhibit_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 54 + }, + { + "ventilation_space_type_name": "guest_room_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 27 + }, + { + "ventilation_space_type_name": "judges_chambers_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 50 + }, + { + "ventilation_space_type_name": "laboratory_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 12 + }, + { + "ventilation_space_type_name": "laundry_washing_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 29 + }, + { + "ventilation_space_type_name": "library_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 51 + }, + { + "ventilation_space_type_name": "living_quarters_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 28 + }, + { + "ventilation_space_type_name": "loading_dock_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 43 + }, + { + "ventilation_space_type_name": "lobby_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 36 + }, + { + "ventilation_space_type_name": "locker_room_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 22 + }, + { + "ventilation_space_type_name": "lounge_breakroom_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 22 + }, + { + "ventilation_space_type_name": "medical_supply_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 41 + }, + { + "ventilation_space_type_name": "multifamily_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 27 + }, + { + "ventilation_space_type_name": "nurses_station_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 34 + }, + { + "ventilation_space_type_name": "office_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 33 + }, + { + "ventilation_space_type_name": "office_enclosed_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 33 + }, + { + "ventilation_space_type_name": "pharmacy_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 41 + }, + { + "ventilation_space_type_name": "playing_area_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 65 + }, + { + "ventilation_space_type_name": "plenum_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 75 + }, + { + "ventilation_space_type_name": "post_office_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 43 + }, + { + "ventilation_space_type_name": "recreation_common_living_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 32 + }, + { + "ventilation_space_type_name": "retail_sales_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 57 + }, + { + "ventilation_space_type_name": "shaft_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 75 + }, + { + "ventilation_space_type_name": "sleeping_quarters_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 28 + }, + { + "ventilation_space_type_name": "sports_arena_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 64 + }, + { + "ventilation_space_type_name": "stairwell_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 75 + }, + { + "ventilation_space_type_name": "storage_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 26 + }, + { + "ventilation_space_type_name": "transportation_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 45 + }, + { + "ventilation_space_type_name": "worship_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 48 + }, + { + "ventilation_space_type_name": "correctional_facilities_booking_waiting_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 4 + }, + { + "ventilation_space_type_name": "correctional_facilities_day_room_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 2 + }, + { + "ventilation_space_type_name": "correctional_facilities_guard_stations_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 3 + }, + { + "ventilation_space_type_name": "educational_facilities_art_classroom_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 11 + }, + { + "ventilation_space_type_name": "educational_facilities_classrooms_ages_5-8_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 7 + }, + { + "ventilation_space_type_name": "educational_facilities_daycare_through_age_4_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 5 + }, + { + "ventilation_space_type_name": "educational_facilities_lecture_classroom_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 9 + }, + { + "ventilation_space_type_name": "educational_facilities_lecture_hall_fixed_seats_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 10 + }, + { + "ventilation_space_type_name": "educational_facilities_media_center_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 16 + }, + { + "ventilation_space_type_name": "educational_facilities_multi-use_assembly_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 18 + }, + { + "ventilation_space_type_name": "educational_facilities_music_theater_dance_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 17 + }, + { + "ventilation_space_type_name": "educational_facilities_science_laboratories_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", "level_3_ventilation_definition_id": 12 }, { - "ventilation_space_type_name": "educational_facilities_computer_lab", + "ventilation_space_type_name": "educational_facilities_wood_metal_shop_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 14 + }, + { + "ventilation_space_type_name": "food_and_beverage_service_bars_cocktail_lounges_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 21 + }, + { + "ventilation_space_type_name": "food_and_beverage_service_cafeteria_fast_food_dining_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 20 + }, + { + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_lobbies_prefunction_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 31 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_bank_vaults_safe_deposit_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 37 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_computer_not_printing_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 38 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_photo_studios_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 42 + }, + { + "ventilation_space_type_name": "miscellaneous_spaces_warehouses_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 46 + }, + { + "ventilation_space_type_name": "public_assembly_spaces_lobbies_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 52 + }, + { + "ventilation_space_type_name": "public_assembly_spaces_museums_childrens_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 53 + }, + { + "ventilation_space_type_name": "retail_barber_shop_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 59 + }, + { + "ventilation_space_type_name": "retail_beauty_and_nail_salons_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 60 + }, + { + "ventilation_space_type_name": "retail_coin-operated_laundries_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 63 + }, + { + "ventilation_space_type_name": "retail_pet_shops_animal_areas_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 61 + }, + { + "ventilation_space_type_name": "retail_supermarket_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 62 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_bowling_alley_seating_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 71 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_disco_dance_floors_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 68 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_gambling_casinos_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 72 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_game_arcades_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 73 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_health_club_weight_rooms_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 70 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_spectator_areas_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 66 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_stages_studios_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 74 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_swimming_pool_deck_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2007", + "level_3_ventilation_definition_id": 67 + }, + { + "ventilation_space_type_name": "airport_concourse_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 13 + "level_3_ventilation_definition_id": 28 }, { - "ventilation_space_type_name": "educational_facilities_media_center", + "ventilation_space_type_name": "atrium_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 14 + "level_3_ventilation_definition_id": 30 }, { - "ventilation_space_type_name": "educational_facilities_music_theater_dance", + "ventilation_space_type_name": "attic_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 15 + "level_3_ventilation_definition_id": 64 }, { - "ventilation_space_type_name": "educational_facilities_multiuse_assembly", + "ventilation_space_type_name": "audience_seating_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 16 + "level_3_ventilation_definition_id": 38 }, { - "ventilation_space_type_name": "food_beverage_service_restaurant_dining_rooms", + "ventilation_space_type_name": "baggage_carousel_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 17 + "level_3_ventilation_definition_id": 28 }, { - "ventilation_space_type_name": "food_beverage_service_cafeteria_fast_food_dining", + "ventilation_space_type_name": "banking_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 18 + "level_3_ventilation_definition_id": 28 }, { - "ventilation_space_type_name": "food_beverage_service_bars_cocktail_lounges", + "ventilation_space_type_name": "classroom_lecture_training_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 19 + "level_3_ventilation_definition_id": 7 }, { - "ventilation_space_type_name": "general_conference_meeting", + "ventilation_space_type_name": "computer_room_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "level_3_ventilation_definition_id": 13 + }, + { + "ventilation_space_type_name": "conference_meeting_multipurpose_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 20 }, { - "ventilation_space_type_name": "general_conference_corridors", + "ventilation_space_type_name": "confinement_cells_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "level_3_ventilation_definition_id": 1 + }, + { + "ventilation_space_type_name": "copy_print_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "level_3_ventilation_definition_id": 29 + }, + { + "ventilation_space_type_name": "corridor_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 21 }, { - "ventilation_space_type_name": "general_conference_storage_rooms", + "ventilation_space_type_name": "courtroom_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 22 + "level_3_ventilation_definition_id": 40 }, { - "ventilation_space_type_name": "hotels_motels_resorts_dormitories_bedroom_living_room", + "ventilation_space_type_name": "datacenterhighite_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 23 + "level_3_ventilation_definition_id": 64 }, { - "ventilation_space_type_name": "hotels_motels_resorts_dormitories_barracks_sleeping_areas", + "ventilation_space_type_name": "datacenterlowite_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 24 + "level_3_ventilation_definition_id": 64 }, { - "ventilation_space_type_name": "hotels_motels_resorts_dormitories_lobbies_prefunction", + "ventilation_space_type_name": "dining_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 25 + "level_3_ventilation_definition_id": 17 }, { - "ventilation_space_type_name": "hotels_motels_resorts_dormitories_multi_purpose_assembly", + "ventilation_space_type_name": "dressing_room_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 26 + "level_3_ventilation_definition_id": 47 }, { - "ventilation_space_type_name": "office_buildings_office_space", + "ventilation_space_type_name": "electrical_mechanical_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 27 + "level_3_ventilation_definition_id": 64 }, { - "ventilation_space_type_name": "office_buildings_reception_areas", + "ventilation_space_type_name": "exercise_area_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 28 + "level_3_ventilation_definition_id": 58 }, { - "ventilation_space_type_name": "office_buildings_telephone_data_entry", + "ventilation_space_type_name": "exhibit_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 29 + "level_3_ventilation_definition_id": 45 + }, + { + "ventilation_space_type_name": "guest_room_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "level_3_ventilation_definition_id": 23 + }, + { + "ventilation_space_type_name": "judges_chambers_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "level_3_ventilation_definition_id": 41 + }, + { + "ventilation_space_type_name": "laboratory_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "level_3_ventilation_definition_id": 11 }, { - "ventilation_space_type_name": "office_buildings_main_entry_lobbies", + "ventilation_space_type_name": "library_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "level_3_ventilation_definition_id": 42 + }, + { + "ventilation_space_type_name": "living_quarters_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "level_3_ventilation_definition_id": 24 + }, + { + "ventilation_space_type_name": "loading_dock_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "level_3_ventilation_definition_id": 35 + }, + { + "ventilation_space_type_name": "lobby_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 30 }, { - "ventilation_space_type_name": "miscellaneous_spaces_bank_ vaults_safe_deposit", + "ventilation_space_type_name": "medical_supply_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 31 + "level_3_ventilation_definition_id": 33 }, { - "ventilation_space_type_name": "miscellaneous_spaces_computer", + "ventilation_space_type_name": "multifamily_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 32 + "level_3_ventilation_definition_id": 23 }, { - "ventilation_space_type_name": "miscellaneous_spaces_pharmacy", + "ventilation_space_type_name": "nurses_station_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "level_3_ventilation_definition_id": 28 + }, + { + "ventilation_space_type_name": "office_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "level_3_ventilation_definition_id": 27 + }, + { + "ventilation_space_type_name": "office_enclosed_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "level_3_ventilation_definition_id": 27 + }, + { + "ventilation_space_type_name": "pharmacy_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 33 }, { - "ventilation_space_type_name": "miscellaneous_spaces_photo_studios", + "ventilation_space_type_name": "playing_area_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 34 + "level_3_ventilation_definition_id": 53 + }, + { + "ventilation_space_type_name": "plenum_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "level_3_ventilation_definition_id": 64 }, { - "ventilation_space_type_name": "miscellaneous_spaces_shipping_receiving", + "ventilation_space_type_name": "post_office_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 35 }, { - "ventilation_space_type_name": "miscellaneous_spaces_transportation_waiting", + "ventilation_space_type_name": "recreation_common_living_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 36 + "level_3_ventilation_definition_id": 26 }, { - "ventilation_space_type_name": "miscellaneous_spaces_warehouses", + "ventilation_space_type_name": "retail_sales_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 37 + "level_3_ventilation_definition_id": 46 }, { - "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area", + "ventilation_space_type_name": "shaft_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 38 + "level_3_ventilation_definition_id": 64 + }, + { + "ventilation_space_type_name": "sleeping_quarters_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "level_3_ventilation_definition_id": 24 + }, + { + "ventilation_space_type_name": "sports_arena_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "level_3_ventilation_definition_id": 53 }, { - "ventilation_space_type_name": "public_assembly_spaces_religious_workshop", + "ventilation_space_type_name": "stairwell_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "level_3_ventilation_definition_id": 64 + }, + { + "ventilation_space_type_name": "storage_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "level_3_ventilation_definition_id": 22 + }, + { + "ventilation_space_type_name": "transportation_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "level_3_ventilation_definition_id": 36 + }, + { + "ventilation_space_type_name": "worship_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 39 }, { - "ventilation_space_type_name": "public_assembly_spaces_courtrooms", + "ventilation_space_type_name": "correctional_facilities_booking_waiting_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 40 + "level_3_ventilation_definition_id": 4 }, { - "ventilation_space_type_name": "public_assembly_spaces_legislative_chambers", + "ventilation_space_type_name": "correctional_facilities_day_room_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 41 + "level_3_ventilation_definition_id": 2 }, { - "ventilation_space_type_name": "public_assembly_spaces_libraries", + "ventilation_space_type_name": "correctional_facilities_guard_stations_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 42 + "level_3_ventilation_definition_id": 3 }, { - "ventilation_space_type_name": "public_assembly_spaces_lobbies", + "ventilation_space_type_name": "educational_facilities_art_classroom_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 43 + "level_3_ventilation_definition_id": 10 }, { - "ventilation_space_type_name": "public_assembly_spaces_children_museums", + "ventilation_space_type_name": "educational_facilities_classrooms_ages_5-8_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 44 + "level_3_ventilation_definition_id": 6 }, { - "ventilation_space_type_name": "public_assembly_spaces_museums_galleries", + "ventilation_space_type_name": "educational_facilities_daycare_through_age_4_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 45 + "level_3_ventilation_definition_id": 5 }, { - "ventilation_space_type_name": "retail_sales", + "ventilation_space_type_name": "educational_facilities_lecture_classroom_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 46 + "level_3_ventilation_definition_id": 8 }, { - "ventilation_space_type_name": "retail_mall_common_areas", + "ventilation_space_type_name": "educational_facilities_lecture_hall_fixed_seats_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 47 + "level_3_ventilation_definition_id": 9 }, { - "ventilation_space_type_name": "retail_barbershop", + "ventilation_space_type_name": "educational_facilities_media_center_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 48 + "level_3_ventilation_definition_id": 14 }, { - "ventilation_space_type_name": "retail_beauty_nail_salons", + "ventilation_space_type_name": "educational_facilities_multi-use_assembly_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 49 + "level_3_ventilation_definition_id": 16 }, { - "ventilation_space_type_name": "retail_pet_shops", + "ventilation_space_type_name": "educational_facilities_music_theater_dance_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 50 + "level_3_ventilation_definition_id": 15 }, { - "ventilation_space_type_name": "retail_supermarket", + "ventilation_space_type_name": "educational_facilities_science_laboratories_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 51 + "level_3_ventilation_definition_id": 11 }, { - "ventilation_space_type_name": "retail_coin_operated_laundries", + "ventilation_space_type_name": "educational_facilities_wood_metal_shop_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 52 + "level_3_ventilation_definition_id": 12 }, { - "ventilation_space_type_name": "sports_entertainment_sports_arena", + "ventilation_space_type_name": "food_and_beverage_service_bars_cocktail_lounges_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 53 + "level_3_ventilation_definition_id": 19 }, { - "ventilation_space_type_name": "sports_entertainment_gym_stadium", + "ventilation_space_type_name": "food_and_beverage_service_cafeteria_fast_food_dining_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 54 + "level_3_ventilation_definition_id": 18 }, { - "ventilation_space_type_name": "sports_entertainment_spectator_areas", + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_lobbies_prefunction_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 55 + "level_3_ventilation_definition_id": 25 }, { - "ventilation_space_type_name": "sports_entertainment_swimming", + "ventilation_space_type_name": "miscellaneous_spaces_bank_vaults_safe_deposit_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 56 + "level_3_ventilation_definition_id": 31 }, { - "ventilation_space_type_name": "sports_entertainment_disco_dance_floors", + "ventilation_space_type_name": "miscellaneous_spaces_computer_not_printing_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 57 + "level_3_ventilation_definition_id": 32 }, { - "ventilation_space_type_name": "sports_entertainment_health_club_aerobics_room", + "ventilation_space_type_name": "miscellaneous_spaces_photo_studios_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 58 + "level_3_ventilation_definition_id": 34 }, { - "ventilation_space_type_name": "sports_entertainment_health_club_weight_rooms", + "ventilation_space_type_name": "miscellaneous_spaces_warehouses_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", - "level_3_ventilation_definition_id": 59 + "level_3_ventilation_definition_id": 37 + }, + { + "ventilation_space_type_name": "public_assembly_spaces_lobbies_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "level_3_ventilation_definition_id": 43 + }, + { + "ventilation_space_type_name": "public_assembly_spaces_museums_childrens_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "level_3_ventilation_definition_id": 44 + }, + { + "ventilation_space_type_name": "retail_barber_shop_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "level_3_ventilation_definition_id": 48 + }, + { + "ventilation_space_type_name": "retail_beauty_and_nail_salons_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "level_3_ventilation_definition_id": 49 + }, + { + "ventilation_space_type_name": "retail_coin-operated_laundries_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "level_3_ventilation_definition_id": 52 + }, + { + "ventilation_space_type_name": "retail_pet_shops_animal_areas_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "level_3_ventilation_definition_id": 50 + }, + { + "ventilation_space_type_name": "retail_supermarket_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "level_3_ventilation_definition_id": 51 }, { - "ventilation_space_type_name": "sports_entertainment_bowling_alley", + "ventilation_space_type_name": "sports_and_entertainment_bowling_alley_seating_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 60 }, { - "ventilation_space_type_name": "sports_entertainment_gambling_casinos", + "ventilation_space_type_name": "sports_and_entertainment_disco_dance_floors_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "level_3_ventilation_definition_id": 57 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_gambling_casinos_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 61 }, { - "ventilation_space_type_name": "sports_entertainment_game_arcades", + "ventilation_space_type_name": "sports_and_entertainment_game_arcades_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 62 }, { - "ventilation_space_type_name": "sports_entertainment_stages_studios", + "ventilation_space_type_name": "sports_and_entertainment_health_club_weight_rooms_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "level_3_ventilation_definition_id": 59 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_spectator_areas_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "level_3_ventilation_definition_id": 55 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_stages_studios_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", "level_3_ventilation_definition_id": 63 + }, + { + "ventilation_space_type_name": "sports_and_entertainment_swimming_pool_deck_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_2004", + "level_3_ventilation_definition_id": 56 + }, + { + "ventilation_space_type_name": "emergency_room_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", + "level_3_ventilation_definition_id": 83 + }, + { + "ventilation_space_type_name": "emergency_vehicle_garage_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", + "level_3_ventilation_definition_id": 83 + }, + { + "ventilation_space_type_name": "exam_treatment_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", + "level_3_ventilation_definition_id": 83 + }, + { + "ventilation_space_type_name": "imaging_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", + "level_3_ventilation_definition_id": 83 + }, + { + "ventilation_space_type_name": "interior_parking_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", + "level_3_ventilation_definition_id": 83 + }, + { + "ventilation_space_type_name": "food_preparation_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", + "level_3_ventilation_definition_id": 83 + }, + { + "ventilation_space_type_name": "laundry_washing_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", + "level_3_ventilation_definition_id": 83 + }, + { + "ventilation_space_type_name": "locker_room_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", + "level_3_ventilation_definition_id": 83 + }, + { + "ventilation_space_type_name": "lounge_breakroom_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", + "level_3_ventilation_definition_id": 83 + }, + { + "ventilation_space_type_name": "nursery_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", + "level_3_ventilation_definition_id": 83 + }, + { + "ventilation_space_type_name": "operating_room_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", + "level_3_ventilation_definition_id": 83 + }, + { + "ventilation_space_type_name": "patient_room_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", + "level_3_ventilation_definition_id": 83 + }, + { + "ventilation_space_type_name": "physical_therapy_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", + "level_3_ventilation_definition_id": 83 + }, + { + "ventilation_space_type_name": "recovery_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", + "level_3_ventilation_definition_id": 83 + }, + { + "ventilation_space_type_name": "restroom_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", + "level_3_ventilation_definition_id": 83 + }, + { + "ventilation_space_type_name": "vehicular_maintenance_ventilation", + "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", + "level_3_ventilation_definition_id": 83 } ] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2004.csv b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2004.csv index 9cade0dbf9..4e770b2f3a 100644 --- a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2004.csv +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2004.csv @@ -1,126 +1,127 @@ -method,lighting_primary_space_type,lighting_per_area,lighting_secondary_space_type,lighting_per_area_unit,annotation -BA,Automotive Facility,0.9,General,W/ft2, -BA,Convention Center,1.2,General,W/ft2, -BA,Court House,1.2,General,W/ft2, -BA,Dining: Bar Lounge/Leisure,1.3,General,W/ft2, -BA,Dining: Cafeteria/Fast Food,1.4,General,W/ft2, -BA,Dining: Family,1.6,General,W/ft2, -BA,Dormitory,1,General,W/ft2, -BA,Exercise Center,1,General,W/ft2, -BA,Gymnasium,1.1,General,W/ft2, -BA,Health Care-Clinic,1,General,W/ft2, -BA,Hospital,1.2,General,W/ft2, -BA,Hotel,1,General,W/ft2, -BA,Library,1.3,General,W/ft2, -BA,Manufacturing Facility,1.3,General,W/ft2, -BA,Motel,1,General,W/ft2, -BA,Motion Picture Theater,1.2,General,W/ft2, -BA,Multi-Family,0.7,General,W/ft2, -BA,Museum,1.1,General,W/ft2, -BA,Office,1,General,W/ft2, -BA,Parking Garage,0.3,General,W/ft2, -BA,Penitentiary,1,General,W/ft2, -BA,Performing Arts Theater,1.6,General,W/ft2, -BA,Police/Fire Station,1,General,W/ft2, -BA,Post Office,1.1,General,W/ft2, -BA,Religious Building,1.3,General,W/ft2, -BA,Retail,1.5,General,W/ft2, -BA,School/University,1.2,General,W/ft2, -BA,Sports Arena,1.1,General,W/ft2, -BA,Town Hall,1.1,General,W/ft2, -BA,Transportation,1,General,W/ft2, -BA,Warehouse,0.8,General,W/ft2, -BA,Workshop,1.4,General,W/ft2, -CS,Office-Enclosed,1.1,General,W/ft2, -CS,Office-Open Plan,1.1,General,W/ft2, -CS,Conference/Meeting/Multipurpose,1.3,General,W/ft2, -CS,Classroom/Lecture/Training,1.4,General,W/ft2, -CS,Classroom/Lecture/Training,1.3,For Penitentiary,W/ft2, -CS,Lobby,1.3,General,W/ft2, -CS,Lobby,1.1,For Hotel,W/ft2, -CS,Lobby,3.3,For Performing Arts Theater,W/ft2, -CS,Lobby,1.1,For Motion Picture Theater,W/ft2, -CS,Audience/Seating Area,0.9,General,W/ft2, -CS,Audience/Seating Area,0.4,For Gymnasium,W/ft2, -CS,Audience/Seating Area,0.3,For Exercise Center,W/ft2, -CS,Audience/Seating Area,0.7,For Convention Center,W/ft2, -CS,Audience/Seating Area,0.7,For Penitentiary,W/ft2, -CS,Audience/Seating Area,1.7,For Religious Buildings,W/ft2, -CS,Audience/Seating Area,0.4,For Sports Arena,W/ft2, -CS,Audience/Seating Area,2.6,For Performing Arts Theater,W/ft2, -CS,Audience/Seating Area,1.2,For Motion Picture Theater,W/ft2, -CS,Audience/Seating Area,0.5,For Transportation,W/ft2, -CS,Atrium: First Three Floors,0.6,General,W/ft2, -CS,Atrium: Each Additional Floor,0.2,General,W/ft2, -CS,Lounge/Recreation,1.2,General,W/ft2, -CS,Lounge/Recreation,0.8,For Hospital,W/ft2, -CS,Dining Area,0.9,General,W/ft2, -CS,Dining Area,1.3,For Penitentiary,W/ft2, -CS,Dining Area,1.3,For Hotel,W/ft2, -CS,Dining Area,1.2,For Motel,W/ft2, -CS,Dining Area,1.4,For Bar Lounge/Leisure Dining,W/ft2, -CS,Dining Area,2.1,For Family Dining,W/ft2, -CS,Food Preparation,1.2,General,W/ft2, -CS,Laboratory,1.4,General,W/ft2, -CS,Restrooms,0.9,General,W/ft2, -CS,Dressing/Locker/Fitting Room,0.6,General,W/ft2, -CS,Corridor/Transition,0.5,General,W/ft2, -CS,Corridor/Transition,1,For Hospital,W/ft2, -CS,Corridor/Transition,0.5,For Manufacturing Facility,W/ft2, -CS,Stairs: Active,0.6,General,W/ft2, -CS,Active Storage,0.8,General,W/ft2, -CS,Active Storage,0.9,For Hospital,W/ft2, -CS,Inactive Storage,0.3,General,W/ft2, -CS,Inactive Storage,0.8,For Museum,W/ft2, -CS,Electrical/Mechanical,1.5,General,W/ft2, -CS,Workshop,1.9,General,W/ft2, -SS,Gymnasium/Exercise Center,1.4,Playing Area,W/ft2, -SS,Gymnasium/Exercise Center,0.9,Exercise Area,W/ft2, -SS,Courthouse/Police Station/Penitentiary,1.9,Courtroom,W/ft2, -SS,Courthouse/Police Station/Penitentiary,0.9,Confinement Cells,W/ft2, -SS,Courthouse/Police Station/Penitentiary,1.3,Judges Chambers,W/ft2, -SS,Fire Stations,0.8,Fire Station Engine Room,W/ft2, -SS,Fire Stations,0.3,Sleeping Quarters,W/ft2, -SS,Post Office: Sorting Area,1.2,General,W/ft2, -SS,Convention Center: Exhibit Space,1.3,General,W/ft2, -SS,Library,1.1,Card File and Cataloging,W/ft2, -SS,Library,1.7,Stacks,W/ft2, -SS,Library,1.2,Reading Area,W/ft2, -SS,Hospital,2.7,Emergency,W/ft2, -SS,Hospital,0.8,Recovery,W/ft2, -SS,Hospital,1,Nurse Station,W/ft2, -SS,Hospital,1.5,Exam/Treatment,W/ft2, -SS,Hospital,1.2,Pharmacy,W/ft2, -SS,Hospital,0.7,Patient Room,W/ft2, -SS,Hospital,2.2,Operating Room,W/ft2, -SS,Hospital,0.6,Nursery,W/ft2, -SS,Hospital,1.4,Medical Supply,W/ft2, -SS,Hospital,0.9,Physical Therapy,W/ft2, -SS,Hospital,0.4,Radiology,W/ft2, -SS,Hospital,0.6,Laundry: Washing,W/ft2, -SS,Automotive: Service/Repair,0.7,General,W/ft2, -SS,Manufacturing,1.2,Low Bay (<25 ft Floor to Ceiling Height),W/ft2, -SS,Manufacturing,1.7,High Bay (>25 ft Floor to Ceiling Height),W/ft2, -SS,Manufacturing,2.1,Detailed Manufacturing,W/ft2, -SS,Manufacturing,1.2,Equipment Room,W/ft2, -SS,Manufacturing,0.5,Control Room,W/ft2, -SS,Hotel/Motel Guest Rooms,1.1,General,W/ft2, -SS,Dormitory: Living Quarters,1.1,General,W/ft2, -SS,Museum,1,General Exhibition,W/ft2, -SS,Museum,1.7,Restoration,W/ft2, -SS,Bank/Office: Banking Activity Area,1.5,General,W/ft2, -SS,Religious Buildings,2.4,"Worship Pulpit, Choir",W/ft2, -SS,Religious Buildings,0.9,Fellowship Hall,W/ft2, -SS,Retail,1.7,Sales Area,W/ft2, -SS,Retail,1.7,Mall Concourse,W/ft2, -SS,Sports Arena,2.7,Ring Sports Area,W/ft2, -SS,Sports Arena,2.3,Court Sports Area,W/ft2, -SS,Sports Arena,1.4,Indoor Playing Field Area,W/ft2, -SS,Warehouse,1.4,Fine Material Storage,W/ft2, -SS,Warehouse,0.9,Medium/Bulky Material Storage,W/ft2, -SS,Parking Garage: Garage Area,0.2,General,W/ft2, -SS,Transportation,0.6,Airport: Concourse,W/ft2, -SS,Transportation,1,Air/Train/Bus: Baggage Area,W/ft2, -SS,Transportation,1.5,Terminal: Ticket Counter,W/ft2, -SS,Retail,1.6,Sales Additional (Specific Display),W/ft2, -SS,Retail,3.9,Sales Additional (Valuable Merchandise),W/ft2, +method,lighting_primary_space_type,lighting_secondary_space_type,lighting_power_density,unit,rcr_threshold,automatic_daylight_responsive_controls_for_sidelighting,automatic_daylight_responsive_controls_for_toplighting,automatic_partial_off,automatic_full_off,scheduled_shutoff,annotation +BA,Automotive Facility,General,0.9,W/ft2,,,,,,, +BA,Convention Center,General,1.2,W/ft2,,,,,,, +BA,Court House,General,1.2,W/ft2,,,,,,, +BA,Dining: Bar Lounge/Leisure,General,1.3,W/ft2,,,,,,, +BA,Dining: Cafeteria/Fast Food,General,1.4,W/ft2,,,,,,, +BA,Dining: Family,General,1.6,W/ft2,,,,,,, +BA,Dormitory,General,1,W/ft2,,,,,,, +BA,Exercise Center,General,1,W/ft2,,,,,,, +BA,Gymnasium,General,1.1,W/ft2,,,,,,, +BA,Health Care-Clinic,General,1,W/ft2,,,,,,, +BA,Hospital,General,1.2,W/ft2,,,,,,, +BA,Hotel,General,1,W/ft2,,,,,,, +BA,Library,General,1.3,W/ft2,,,,,,, +BA,Manufacturing Facility,General,1.3,W/ft2,,,,,,, +BA,Motel,General,1,W/ft2,,,,,,, +BA,Motion Picture Theater,General,1.2,W/ft2,,,,,,, +BA,Multi-Family,General,0.7,W/ft2,,,,,,, +BA,Museum,General,1.1,W/ft2,,,,,,, +BA,Office,General,1,W/ft2,,,,,,, +BA,Parking Garage,General,0.3,W/ft2,,,,,,, +BA,Penitentiary,General,1,W/ft2,,,,,,, +BA,Performing Arts Theater,General,1.6,W/ft2,,,,,,, +BA,Police/Fire Station,General,1,W/ft2,,,,,,, +BA,Post Office,General,1.1,W/ft2,,,,,,, +BA,Religious Building,General,1.3,W/ft2,,,,,,, +BA,Retail,General,1.5,W/ft2,,,,,,, +BA,School/University,General,1.2,W/ft2,,,,,,, +BA,Sports Arena,General,1.1,W/ft2,,,,,,, +BA,Town Hall,General,1.1,W/ft2,,,,,,, +BA,Transportation,General,1,W/ft2,,,,,,, +BA,Warehouse,General,0.8,W/ft2,,,,,,, +BA,Workshop,General,1.4,W/ft2,,,,,,, +CS,Office-Enclosed,General,1.1,W/ft2,,,,,,, +CS,Office-Open Plan,General,1.1,W/ft2,,,,,,, +CS,Conference/Meeting/Multipurpose,General,1.3,W/ft2,,,,,REQ,, +CS,Classroom/Lecture/Training,General,1.4,W/ft2,,,,,REQ,, +CS,Classroom/Lecture/Training,For Penitentiary,1.3,W/ft2,,,,,REQ,, +CS,Lobby,General,1.3,W/ft2,,,,,,, +CS,Lobby,For Hotel,1.1,W/ft2,,,,,,, +CS,Lobby,For Performing Arts Theater,3.3,W/ft2,,,,,,, +CS,Lobby,For Motion Picture Theater,1.1,W/ft2,,,,,,, +CS,Audience/Seating Area,General,0.9,W/ft2,,,,,,, +CS,Audience/Seating Area,For Gymnasium,0.4,W/ft2,,,,,,, +CS,Audience/Seating Area,For Exercise Center,0.3,W/ft2,,,,,,, +CS,Audience/Seating Area,For Convention Center,0.7,W/ft2,,,,,,, +CS,Audience/Seating Area,For Penitentiary,0.7,W/ft2,,,,,,, +CS,Audience/Seating Area,For Religious Buildings,1.7,W/ft2,,,,,,, +CS,Audience/Seating Area,For Sports Arena,0.4,W/ft2,,,,,,, +CS,Audience/Seating Area,For Performing Arts Theater,2.6,W/ft2,,,,,,, +CS,Audience/Seating Area,For Motion Picture Theater,1.2,W/ft2,,,,,,, +CS,Audience/Seating Area,For Transportation,0.5,W/ft2,,,,,,, +CS,Atrium: First Three Floors,General,0.6,W/ft2,,,,,,, +CS,Atrium: Each Additional Floor,General,0.2,W/ft2,,,,,,, +CS,Lounge/Recreation,General,1.2,W/ft2,,,,,REQ,, +CS,Lounge/Recreation,For Hospital,0.8,W/ft2,,,,,REQ,, +CS,Dining Area,General,0.9,W/ft2,,,,,,, +CS,Dining Area,For Penitentiary,1.3,W/ft2,,,,,,, +CS,Dining Area,For Hotel,1.3,W/ft2,,,,,,, +CS,Dining Area,For Motel,1.2,W/ft2,,,,,,, +CS,Dining Area,For Bar Lounge/Leisure Dining,1.4,W/ft2,,,,,,, +CS,Dining Area,For Family Dining,2.1,W/ft2,,,,,,, +CS,Food Preparation,General,1.2,W/ft2,,,,,,, +CS,Laboratory,General,1.4,W/ft2,,,,,,, +CS,Restrooms,General,0.9,W/ft2,,,,,,, +CS,Dressing/Locker/Fitting Room,General,0.6,W/ft2,,,,,,, +CS,Corridor/Transition,General,0.5,W/ft2,,,,,,, +CS,Corridor/Transition,For Hospital,1,W/ft2,,,,,,, +CS,Corridor/Transition,For Manufacturing Facility,0.5,W/ft2,,,,,,, +CS,Stairs: Active,General,0.6,W/ft2,,,,,,, +CS,Active Storage,General,0.8,W/ft2,,,,,,, +CS,Active Storage,For Hospital,0.9,W/ft2,,,,,,, +CS,Inactive Storage,General,0.3,W/ft2,,,,,,, +CS,Inactive Storage,For Museum,0.8,W/ft2,,,,,,, +CS,Electrical/Mechanical,General,1.5,W/ft2,,,,,,, +CS,Workshop,General,1.9,W/ft2,,,,,,, +SS,Gymnasium/Exercise Center,Playing Area,1.4,W/ft2,,,,,,, +SS,Gymnasium/Exercise Center,Exercise Area,0.9,W/ft2,,,,,,, +SS,Courthouse/Police Station/Penitentiary,Courtroom,1.9,W/ft2,,,,,,, +SS,Courthouse/Police Station/Penitentiary,Confinement Cells,0.9,W/ft2,,,,,,, +SS,Courthouse/Police Station/Penitentiary,Judges Chambers,1.3,W/ft2,,,,,,, +SS,Fire Stations,Fire Station Engine Room,0.8,W/ft2,,,,,,, +SS,Fire Stations,Sleeping Quarters,0.3,W/ft2,,,,,,, +SS,Post Office: Sorting Area,General,1.2,W/ft2,,,,,,, +SS,Convention Center: Exhibit Space,General,1.3,W/ft2,,,,,,, +SS,Library,Card File and Cataloging,1.1,W/ft2,,,,,,, +SS,Library,Stacks,1.7,W/ft2,,,,,,, +SS,Library,Reading Area,1.2,W/ft2,,,,,,, +SS,Hospital,Emergency,2.7,W/ft2,,,,,,, +SS,Hospital,Recovery,0.8,W/ft2,,,,,,, +SS,Hospital,Nurse Station,1,W/ft2,,,,,,, +SS,Hospital,Exam/Treatment,1.5,W/ft2,,,,,,, +SS,Hospital,Pharmacy,1.2,W/ft2,,,,,,, +SS,Hospital,Patient Room,0.7,W/ft2,,,,,,, +SS,Hospital,Operating Room,2.2,W/ft2,,,,,,, +SS,Hospital,Nursery,0.6,W/ft2,,,,,,, +SS,Hospital,Medical Supply,1.4,W/ft2,,,,,,, +SS,Hospital,Physical Therapy,0.9,W/ft2,,,,,,, +SS,Hospital,Radiology,0.4,W/ft2,,,,,,, +SS,Hospital,Laundry: Washing,0.6,W/ft2,,,,,,, +SS,Automotive: Service/Repair,General,0.7,W/ft2,,,,,,, +SS,Manufacturing,Low Bay (<25 ft Floor to Ceiling Height),1.2,W/ft2,,,,,,, +SS,Manufacturing,High Bay (>25 ft Floor to Ceiling Height),1.7,W/ft2,,,,,,, +SS,Manufacturing,Detailed Manufacturing,2.1,W/ft2,,,,,,, +SS,Manufacturing,Equipment Room,1.2,W/ft2,,,,,,, +SS,Manufacturing,Control Room,0.5,W/ft2,,,,,,, +SS,Hotel/Motel Guest Rooms,General,1.1,W/ft2,,,,,,, +SS,Dormitory: Living Quarters,General,1.1,W/ft2,,,,,,, +SS,Museum,General Exhibition,1,W/ft2,,,,,,, +SS,Museum,Restoration,1.7,W/ft2,,,,,,, +SS,Bank/Office Banking Activity Area,General,1.5,W/ft2,,,,,,, +SS,Religious Buildings,"Worship Pulpit, Choir",2.4,W/ft2,,,,,,, +SS,Religious Buildings,Fellowship Hall,0.9,W/ft2,,,,,,, +SS,Retail,Sales Area,1.7,W/ft2,,,,,,, +SS,Retail,Mall Concourse,1.7,W/ft2,,,,,,, +SS,Sports Arena,Ring Sports Area,2.7,W/ft2,,,,,,, +SS,Sports Arena,Court Sports Area,2.3,W/ft2,,,,,,, +SS,Sports Arena,Indoor Playing Field Area,1.4,W/ft2,,,,,,, +SS,Warehouse,Fine Material Storage,1.4,W/ft2,,,,,,, +SS,Warehouse,Medium/Bulky Material Storage,0.9,W/ft2,,,,,,, +SS,Parking Garage: Garage Area,General,0.2,W/ft2,,,,,,, +SS,Transportation,Airport: Concourse,0.6,W/ft2,,,,,,, +SS,Transportation,Air/Train/Bus: Baggage Area,1,W/ft2,,,,,,, +SS,Transportation,Terminal: Ticket Counter,1.5,W/ft2,,,,,,, +SS,Retail,Sales Additional (Specific Display),1.6,W/ft2,,,,,,, +SS,Retail,Sales Additional (Valuable Merchandise),3.9,W/ft2,,,,,,, +SS,None,None,0,W/ft2,,,,,,, diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2004.json b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2004.json index 453e12a0d5..bc5e80c1fa 100644 --- a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2004.json +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2004.json @@ -2,1001 +2,1765 @@ { "method": "BA", "lighting_primary_space_type": "Automotive Facility", - "lighting_per_area": 0.9, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Convention Center", - "lighting_per_area": 1.2, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Court House", - "lighting_per_area": 1.2, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Dining: Bar Lounge/Leisure", - "lighting_per_area": 1.3, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Dining: Cafeteria/Fast Food", - "lighting_per_area": 1.4, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.4, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Dining: Family", - "lighting_per_area": 1.6, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.6, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Dormitory", - "lighting_per_area": 1, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Exercise Center", - "lighting_per_area": 1, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Gymnasium", - "lighting_per_area": 1.1, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Health Care-Clinic", - "lighting_per_area": 1, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Hospital", - "lighting_per_area": 1.2, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Hotel", - "lighting_per_area": 1, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Library", - "lighting_per_area": 1.3, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Manufacturing Facility", - "lighting_per_area": 1.3, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Motel", - "lighting_per_area": 1, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Motion Picture Theater", - "lighting_per_area": 1.2, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Multi-Family", - "lighting_per_area": 0.7, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.7, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Museum", - "lighting_per_area": 1.1, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Office", - "lighting_per_area": 1, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Parking Garage", - "lighting_per_area": 0.3, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Penitentiary", - "lighting_per_area": 1, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Performing Arts Theater", - "lighting_per_area": 1.6, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.6, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Police/Fire Station", - "lighting_per_area": 1, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Post Office", - "lighting_per_area": 1.1, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Religious Building", - "lighting_per_area": 1.3, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Retail", - "lighting_per_area": 1.5, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.5, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "School/University", - "lighting_per_area": 1.2, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Sports Arena", - "lighting_per_area": 1.1, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Town Hall", - "lighting_per_area": 1.1, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Transportation", - "lighting_per_area": 1, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Warehouse", - "lighting_per_area": 0.8, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.8, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Workshop", - "lighting_per_area": 1.4, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.4, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Office-Enclosed", - "lighting_per_area": 1.1, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Office-Open Plan", - "lighting_per_area": 1.1, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Conference/Meeting/Multipurpose", - "lighting_per_area": 1.3, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Classroom/Lecture/Training", - "lighting_per_area": 1.4, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.4, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Classroom/Lecture/Training", - "lighting_per_area": 1.3, "lighting_secondary_space_type": "For Penitentiary", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Lobby", - "lighting_per_area": 1.3, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Lobby", - "lighting_per_area": 1.1, "lighting_secondary_space_type": "For Hotel", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Lobby", - "lighting_per_area": 3.3, "lighting_secondary_space_type": "For Performing Arts Theater", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 3.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Lobby", - "lighting_per_area": 1.1, "lighting_secondary_space_type": "For Motion Picture Theater", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Audience/Seating Area", - "lighting_per_area": 0.9, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Audience/Seating Area", - "lighting_per_area": 0.4, "lighting_secondary_space_type": "For Gymnasium", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.4, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Audience/Seating Area", - "lighting_per_area": 0.3, "lighting_secondary_space_type": "For Exercise Center", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Audience/Seating Area", - "lighting_per_area": 0.7, "lighting_secondary_space_type": "For Convention Center", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.7, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Audience/Seating Area", - "lighting_per_area": 0.7, "lighting_secondary_space_type": "For Penitentiary", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.7, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Audience/Seating Area", - "lighting_per_area": 1.7, "lighting_secondary_space_type": "For Religious Buildings", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.7, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Audience/Seating Area", - "lighting_per_area": 0.4, "lighting_secondary_space_type": "For Sports Arena", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.4, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Audience/Seating Area", - "lighting_per_area": 2.6, "lighting_secondary_space_type": "For Performing Arts Theater", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 2.6, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Audience/Seating Area", - "lighting_per_area": 1.2, "lighting_secondary_space_type": "For Motion Picture Theater", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Audience/Seating Area", - "lighting_per_area": 0.5, "lighting_secondary_space_type": "For Transportation", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.5, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Atrium: First Three Floors", - "lighting_per_area": 0.6, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.6, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Atrium: Each Additional Floor", - "lighting_per_area": 0.2, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Lounge/Recreation", - "lighting_per_area": 1.2, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Lounge/Recreation", - "lighting_per_area": 0.8, "lighting_secondary_space_type": "For Hospital", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.8, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Dining Area", - "lighting_per_area": 0.9, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Dining Area", - "lighting_per_area": 1.3, "lighting_secondary_space_type": "For Penitentiary", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Dining Area", - "lighting_per_area": 1.3, "lighting_secondary_space_type": "For Hotel", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Dining Area", - "lighting_per_area": 1.2, "lighting_secondary_space_type": "For Motel", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Dining Area", - "lighting_per_area": 1.4, "lighting_secondary_space_type": "For Bar Lounge/Leisure Dining", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.4, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Dining Area", - "lighting_per_area": 2.1, "lighting_secondary_space_type": "For Family Dining", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 2.1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Food Preparation", - "lighting_per_area": 1.2, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Laboratory", - "lighting_per_area": 1.4, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.4, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Restrooms", - "lighting_per_area": 0.9, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Dressing/Locker/Fitting Room", - "lighting_per_area": 0.6, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.6, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Corridor/Transition", - "lighting_per_area": 0.5, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.5, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Corridor/Transition", - "lighting_per_area": 1, "lighting_secondary_space_type": "For Hospital", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Corridor/Transition", - "lighting_per_area": 0.5, "lighting_secondary_space_type": "For Manufacturing Facility", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.5, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Stairs: Active", - "lighting_per_area": 0.6, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.6, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Active Storage", - "lighting_per_area": 0.8, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.8, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Active Storage", - "lighting_per_area": 0.9, "lighting_secondary_space_type": "For Hospital", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Inactive Storage", - "lighting_per_area": 0.3, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Inactive Storage", - "lighting_per_area": 0.8, "lighting_secondary_space_type": "For Museum", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.8, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Electrical/Mechanical", - "lighting_per_area": 1.5, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.5, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Workshop", - "lighting_per_area": 1.9, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Gymnasium/Exercise Center", - "lighting_per_area": 1.4, "lighting_secondary_space_type": "Playing Area", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.4, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Gymnasium/Exercise Center", - "lighting_per_area": 0.9, "lighting_secondary_space_type": "Exercise Area", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", - "lighting_per_area": 1.9, "lighting_secondary_space_type": "Courtroom", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", - "lighting_per_area": 0.9, "lighting_secondary_space_type": "Confinement Cells", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", - "lighting_per_area": 1.3, "lighting_secondary_space_type": "Judges Chambers", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Fire Stations", - "lighting_per_area": 0.8, "lighting_secondary_space_type": "Fire Station Engine Room", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.8, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Fire Stations", - "lighting_per_area": 0.3, "lighting_secondary_space_type": "Sleeping Quarters", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Post Office: Sorting Area", - "lighting_per_area": 1.2, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Convention Center: Exhibit Space", - "lighting_per_area": 1.3, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Library", - "lighting_per_area": 1.1, "lighting_secondary_space_type": "Card File and Cataloging", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Library", - "lighting_per_area": 1.7, "lighting_secondary_space_type": "Stacks", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.7, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Library", - "lighting_per_area": 1.2, "lighting_secondary_space_type": "Reading Area", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Hospital", - "lighting_per_area": 2.7, "lighting_secondary_space_type": "Emergency", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 2.7, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Hospital", - "lighting_per_area": 0.8, "lighting_secondary_space_type": "Recovery", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.8, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Hospital", - "lighting_per_area": 1, "lighting_secondary_space_type": "Nurse Station", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Hospital", - "lighting_per_area": 1.5, "lighting_secondary_space_type": "Exam/Treatment", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.5, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Hospital", - "lighting_per_area": 1.2, "lighting_secondary_space_type": "Pharmacy", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Hospital", - "lighting_per_area": 0.7, "lighting_secondary_space_type": "Patient Room", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.7, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Hospital", - "lighting_per_area": 2.2, "lighting_secondary_space_type": "Operating Room", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 2.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Hospital", - "lighting_per_area": 0.6, "lighting_secondary_space_type": "Nursery", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.6, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Hospital", - "lighting_per_area": 1.4, "lighting_secondary_space_type": "Medical Supply", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.4, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Hospital", - "lighting_per_area": 0.9, "lighting_secondary_space_type": "Physical Therapy", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Hospital", - "lighting_per_area": 0.4, "lighting_secondary_space_type": "Radiology", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.4, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Hospital", - "lighting_per_area": 0.6, "lighting_secondary_space_type": "Laundry: Washing", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.6, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Automotive: Service/Repair", - "lighting_per_area": 0.7, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.7, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Manufacturing", - "lighting_per_area": 1.2, "lighting_secondary_space_type": "Low Bay (<25 ft Floor to Ceiling Height)", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Manufacturing", - "lighting_per_area": 1.7, "lighting_secondary_space_type": "High Bay (>25 ft Floor to Ceiling Height)", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.7, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Manufacturing", - "lighting_per_area": 2.1, "lighting_secondary_space_type": "Detailed Manufacturing", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 2.1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Manufacturing", - "lighting_per_area": 1.2, "lighting_secondary_space_type": "Equipment Room", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Manufacturing", - "lighting_per_area": 0.5, "lighting_secondary_space_type": "Control Room", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.5, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Hotel/Motel Guest Rooms", - "lighting_per_area": 1.1, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Dormitory: Living Quarters", - "lighting_per_area": 1.1, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Museum", - "lighting_per_area": 1, "lighting_secondary_space_type": "General Exhibition", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Museum", - "lighting_per_area": 1.7, "lighting_secondary_space_type": "Restoration", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.7, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Bank/Office: Banking Activity Area", - "lighting_per_area": 1.5, + "lighting_primary_space_type": "Bank/Office Banking Activity Area", "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.5, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Religious Buildings", - "lighting_per_area": 2.4, "lighting_secondary_space_type": "Worship Pulpit, Choir", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 2.4, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Religious Buildings", - "lighting_per_area": 0.9, "lighting_secondary_space_type": "Fellowship Hall", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Retail", - "lighting_per_area": 1.7, "lighting_secondary_space_type": "Sales Area", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.7, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Retail", - "lighting_per_area": 1.7, "lighting_secondary_space_type": "Mall Concourse", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.7, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Sports Arena", - "lighting_per_area": 2.7, "lighting_secondary_space_type": "Ring Sports Area", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 2.7, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Sports Arena", - "lighting_per_area": 2.3, "lighting_secondary_space_type": "Court Sports Area", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 2.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Sports Arena", - "lighting_per_area": 1.4, "lighting_secondary_space_type": "Indoor Playing Field Area", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.4, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Warehouse", - "lighting_per_area": 1.4, "lighting_secondary_space_type": "Fine Material Storage", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.4, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Warehouse", - "lighting_per_area": 0.9, "lighting_secondary_space_type": "Medium/Bulky Material Storage", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Parking Garage: Garage Area", - "lighting_per_area": 0.2, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Transportation", - "lighting_per_area": 0.6, "lighting_secondary_space_type": "Airport: Concourse", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.6, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Transportation", - "lighting_per_area": 1, "lighting_secondary_space_type": "Air/Train/Bus: Baggage Area", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Transportation", - "lighting_per_area": 1.5, "lighting_secondary_space_type": "Terminal: Ticket Counter", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.5, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Retail", - "lighting_per_area": 1.6, "lighting_secondary_space_type": "Sales Additional (Specific Display)", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.6, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Retail", - "lighting_per_area": 3.9, "lighting_secondary_space_type": "Sales Additional (Valuable Merchandise)", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 3.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "None", + "lighting_secondary_space_type": "None", + "lighting_power_density": 0, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null } ] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2007.csv b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2007.csv new file mode 100644 index 0000000000..7f0f555710 --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2007.csv @@ -0,0 +1,130 @@ +method,lighting_primary_space_type,lighting_secondary_space_type,lighting_power_density,unit,rcr_threshold,automatic_daylight_responsive_controls_for_sidelighting,automatic_daylight_responsive_controls_for_toplighting,automatic_partial_off,automatic_full_off,scheduled_shutoff,annotation +BA,Automotive Facility,General,0.9,W/ft2,,,,,,, +BA,Convention Center,General,1.2,W/ft2,,,,,,, +BA,Courthouse,General,1.2,W/ft2,,,,,,, +BA,Dining: Bar Lounge/leisure,General,1.3,W/ft2,,,,,,, +BA,Dining: Cafeteria/fast Food,General,1.4,W/ft2,,,,,,, +BA,Dining: Family,General,1.6,W/ft2,,,,,,, +BA,Dormitory,General,1,W/ft2,,,,,,, +BA,Exercise Center,General,1,W/ft2,,,,,,, +BA,Gymnasium,General,1.1,W/ft2,,,,,,, +BA,Health-care Clinic,General,1,W/ft2,,,,,,, +BA,Hospital,General,1.2,W/ft2,,,,,,, +BA,Hotel,General,1,W/ft2,,,,,,, +BA,Library,General,1.3,W/ft2,,,,,,, +BA,Manufacturing Facility,General,1.3,W/ft2,,,,,,, +BA,Motel,General,1,W/ft2,,,,,,, +BA,Motion Picture Theater,General,1.2,W/ft2,,,,,,, +BA,Multifamily,General,0.7,W/ft2,,,,,,, +BA,Museum,General,1.1,W/ft2,,,,,,, +BA,Office,General,1,W/ft2,,,,,,, +BA,Parking Garage,General,0.3,W/ft2,,,,,,, +BA,Penitentiary,General,1,W/ft2,,,,,,, +BA,Performing Arts Theater,General,1.6,W/ft2,,,,,,, +BA,Police/fire Station,General,1,W/ft2,,,,,,, +BA,Post Office,General,1.1,W/ft2,,,,,,, +BA,Religious Building,General,1.3,W/ft2,,,,,,, +BA,Retail,General,1.5,W/ft2,,,,,,, +BA,School/University,General,1.2,W/ft2,,,,,,, +BA,Sports Arena,General,1.1,W/ft2,,,,,,, +BA,Town Hall,General,1.1,W/ft2,,,,,,, +BA,Transportation,General,1,W/ft2,,,,,,, +BA,Warehouse,General,0.8,W/ft2,,,,,,, +BA,Workshop,General,1.4,W/ft2,,,,,,, +CS,Dining Area,For Bar Lounge/Leisure Dining,1.4,W/ft2,,,,,,, +CS,Audience/seating Area,For Convention Center,0.7,W/ft2,,,,,,, +CS,Dining Area,For Family Dining,2.1,W/ft2,,,,,,, +CS,Audience/seating Area,For Exercise Center,0.3,W/ft2,,,,,,, +CS,Active Storage,For Hospital,0.9,W/ft2,,,,,,, +CS,Corridor/transition,For Hospital,1,W/ft2,,,,,,, +CS,Lounge/Recreation,For Hospital,0.8,W/ft2,,,,,REQ,, +CS,Dining Area,For Hotel,1.3,W/ft2,,,,,,, +CS,Lobby,For Hotel,1.1,W/ft2,,,,,,, +CS,Corridor/transition,For Manufacturing Facility,0.5,W/ft2,,,,,,, +CS,Dining Area,For Motel,1.2,W/ft2,,,,,,, +CS,Audience/seating Area,General,0.9,W/ft2,,,,,,, +CS,Lobby,For Motion Picture Theater,1.1,W/ft2,,,,,,, +CS,Inactive Storage,For Museum,0.8,W/ft2,,,,,,, +CS,Classroom/Lecture/Training,For Penitentiary,1.3,W/ft2,,,,,REQ,, +CS,Dining Area,For Penitentiary,1.3,W/ft2,,,,,,, +CS,Audience/seating Area,For Gymnasium,0.4,W/ft2,,,,,,, +CS,Lobby,For Performing Arts Theater,3.3,W/ft2,,,,,,, +CS,Audience/seating Area,For Motion Picture Theater,1.2,W/ft2,,,,,,, +CS,Active Storage,General,0.8,W/ft2,,,,,,, +CS,Atrium each Additional Floor,General,0.2,W/ft2,,,,,,, +CS,Atrium first Three Floors,General,0.6,W/ft2,,,,,,, +CS,Classroom/Lecture/Training,General,1.4,W/ft2,,,,,REQ,, +CS,Conference/Meeting/Multipurpose,General,1.3,W/ft2,,,,,REQ,, +CS,Corridor/transition,General,0.5,W/ft2,,,,,,, +CS,Dining Area,General,0.9,W/ft2,,,,,,, +CS,Dressing/Locker/Fitting Room,General,0.6,W/ft2,,,,,,, +CS,Electrical/Mechanical,General,1.5,W/ft2,,,,,,, +CS,Food Preparation,General,1.2,W/ft2,,,,,,, +CS,Inactive Storage,General,0.3,W/ft2,,,,,,, +CS,Laboratory,General,1.4,W/ft2,,,,,,, +CS,Lobby,General,1.3,W/ft2,,,,,,, +CS,Lounge/Recreation,General,1.2,W/ft2,,,,,REQ,, +CS,Office-Enclosed,General,1.1,W/ft2,,,,,,, +CS,Office-Open Plan,General,1.1,W/ft2,,,,,,, +CS,Restrooms,General,0.9,W/ft2,,,,,,, +CS,Sales Area,General,1.7,W/ft2,,,,,,, +CS,Audience/seating Area,For Penitentiary,0.7,W/ft2,,,,,,, +CS,Stairs active,General,0.6,W/ft2,,,,,,, +CS,Workshop,General,1.9,W/ft2,,,,,,, +CS,Audience/seating Area,For Performing Arts Theater,2.6,W/ft2,,,,,,, +CS,Audience/seating Area,For Religious Buildings,1.7,W/ft2,,,,,,, +CS,Audience/seating Area,For Sports Arena,0.4,W/ft2,,,,,,, +CS,Audience/seating Area,For Transportation,0.5,W/ft2,,,,,,, +SS,Transportation,Air/Train/Bus Baggage Area,1,W/ft2,,,,,,, +SS,Transportation,Airport Concourse,0.6,W/ft2,,,,,,, +SS,Library,Card File and Cataloging,1.1,W/ft2,,,,,,, +SS,Courthouse/Police Station/Penitentiary,Confinement Cells,0.9,W/ft2,,,,,,, +SS,Manufacturing,Control Room,0.5,W/ft2,,,,,,, +SS,Sports Arena,Court Sports Area,2.3,W/ft2,,,,,,, +SS,Courthouse/Police Station/Penitentiary,Courtroom,1.9,W/ft2,,,,,,, +SS,Manufacturing,Detailed Manufacturing,2.1,W/ft2,,,,,,, +SS,Hospital,Emergency,2.7,W/ft2,,,,,,, +SS,Fire Stations,Engine Room,0.8,W/ft2,,,,,,, +SS,Manufacturing,Equipment Room,1.2,W/ft2,,,,,,, +SS,Hospital,Exam/Treatment,1.5,W/ft2,,,,,,, +SS,Gymnasium/exercise Center,Exercise Area,0.9,W/ft2,,,,,,, +SS,Religious Buildings,Fellowship Hall,0.9,W/ft2,,,,,,, +SS,Warehouse,Fine Material Storage,1.4,W/ft2,,,,,,, +SS,Automotive service/repair,General,0.7,W/ft2,,,,,,, +SS,Bank/Office Banking Activity Area,General,1.5,W/ft2,,,,,,, +SS,Convention Center exhibit Space,General,1.3,W/ft2,,,,,,, +SS,Dormitory living Quarters,General,1.1,W/ft2,,,,,,, +SS,Hotel/motel Guest Rooms,General,1.1,W/ft2,,,,,,, +SS,Parking Garage garage Area,General,0.2,W/ft2,,,,,,, +SS,Post Office sorting Area,General,1.2,W/ft2,,,,,,, +SS,Museum,General Exhibition,1,W/ft2,,,,,,, +SS,Manufacturing,High Bay (>25 ft Floor to Ceiling Height),1.7,W/ft2,,,,,,, +SS,Sports Arena,Indoor Playing Field Area,1.4,W/ft2,,,,,,, +SS,Courthouse/Police Station/Penitentiary,Judges Chambers,1.3,W/ft2,,,,,,, +SS,Hospital,Laundry Washing,0.6,W/ft2,,,,,,, +SS,Manufacturing,Low Bay (<25 ft Floor to Ceiling Height),1.2,W/ft2,,,,,,, +SS,Retail,Mall Concourse,1.7,W/ft2,,,,,,, +SS,Hospital,Medical Supply,1.4,W/ft2,,,,,,, +SS,Warehouse,Medium/Bulky Material Storage,0.9,W/ft2,,,,,,, +SS,Hospital,Nurse Station,1,W/ft2,,,,,,, +SS,Hospital,Nursery,0.6,W/ft2,,,,,,, +SS,Hospital,Operating Room,2.2,W/ft2,,,,,,, +SS,Hospital,Patient Room,0.7,W/ft2,,,,,,, +SS,Hospital,Pharmacy,1.2,W/ft2,,,,,,, +SS,Hospital,Physical Therapy,0.9,W/ft2,,,,,,, +SS,Gymnasium/exercise Center,Playing Area,1.4,W/ft2,,,,,,, +SS,Hospital,Radiology,0.4,W/ft2,,,,,,, +SS,Library,Reading Area,1.2,W/ft2,,,,,,, +SS,Hospital,Recovery,0.8,W/ft2,,,,,,, +SS,Museum,Restoration,1.7,W/ft2,,,,,,, +SS,Sports Arena,Ring Sports Area,2.7,W/ft2,,,,,,, +SS,Retail,Sales Additional (Type 1),1,W/ft2,,,,,,, +SS,Retail,Sales Additional (Type 2),1.7,W/ft2,,,,,,, +SS,Retail,Sales Additional (Type 3),2.6,W/ft2,,,,,,, +SS,Retail,Sales Additional (Type 4),4.2,W/ft2,,,,,,, +SS,Retail,Sales Area,1.7,W/ft2,,,,,,, +SS,Fire Stations,Sleeping Quarters,0.3,W/ft2,,,,,,, +SS,Library,Stacks,1.7,W/ft2,,,,,,, +SS,Transportation,Terminal Ticket Counter,1.5,W/ft2,,,,,,, +SS,Religious Buildings,"Worship Pulpit, Choir",2.4,W/ft2,,,,,,, +SS,None,None,0,W/ft2,,,,,,, diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2007.json b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2007.json new file mode 100644 index 0000000000..9181f5184c --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2007.json @@ -0,0 +1,1808 @@ +[ + { + "method": "BA", + "lighting_primary_space_type": "Automotive Facility", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Convention Center", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Courthouse", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Dining: Bar Lounge/leisure", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Dining: Cafeteria/fast Food", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.4, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Dining: Family", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.6, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Dormitory", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Exercise Center", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Gymnasium", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Health-care Clinic", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Hotel", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Library", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Manufacturing Facility", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Motel", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Motion Picture Theater", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Multifamily", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.7, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Museum", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Office", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Parking Garage", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Penitentiary", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Performing Arts Theater", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.6, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Police/fire Station", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Post Office", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Religious Building", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.5, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "School/University", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Sports Arena", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Town Hall", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Transportation", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Warehouse", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.8, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Workshop", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.4, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "For Bar Lounge/Leisure Dining", + "lighting_power_density": 1.4, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "For Convention Center", + "lighting_power_density": 0.7, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "For Family Dining", + "lighting_power_density": 2.1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "For Exercise Center", + "lighting_power_density": 0.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Active Storage", + "lighting_secondary_space_type": "For Hospital", + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Corridor/transition", + "lighting_secondary_space_type": "For Hospital", + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Lounge/Recreation", + "lighting_secondary_space_type": "For Hospital", + "lighting_power_density": 0.8, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "For Hotel", + "lighting_power_density": 1.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "For Hotel", + "lighting_power_density": 1.1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Corridor/transition", + "lighting_secondary_space_type": "For Manufacturing Facility", + "lighting_power_density": 0.5, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "For Motel", + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "For Motion Picture Theater", + "lighting_power_density": 1.1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Inactive Storage", + "lighting_secondary_space_type": "For Museum", + "lighting_power_density": 0.8, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Classroom/Lecture/Training", + "lighting_secondary_space_type": "For Penitentiary", + "lighting_power_density": 1.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "For Penitentiary", + "lighting_power_density": 1.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "For Gymnasium", + "lighting_power_density": 0.4, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "For Performing Arts Theater", + "lighting_power_density": 3.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "For Motion Picture Theater", + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Active Storage", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.8, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Atrium each Additional Floor", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Atrium first Three Floors", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.6, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Classroom/Lecture/Training", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.4, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Conference/Meeting/Multipurpose", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Corridor/transition", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.5, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Dressing/Locker/Fitting Room", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.6, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Electrical/Mechanical", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.5, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Food Preparation", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Inactive Storage", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Laboratory", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.4, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Lounge/Recreation", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Office-Enclosed", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Office-Open Plan", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Restrooms", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Sales Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.7, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "For Penitentiary", + "lighting_power_density": 0.7, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Stairs active", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.6, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Workshop", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "For Performing Arts Theater", + "lighting_power_density": 2.6, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "For Religious Buildings", + "lighting_power_density": 1.7, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "For Sports Arena", + "lighting_power_density": 0.4, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "For Transportation", + "lighting_power_density": 0.5, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Transportation", + "lighting_secondary_space_type": "Air/Train/Bus Baggage Area", + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Transportation", + "lighting_secondary_space_type": "Airport Concourse", + "lighting_power_density": 0.6, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Library", + "lighting_secondary_space_type": "Card File and Cataloging", + "lighting_power_density": 1.1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", + "lighting_secondary_space_type": "Confinement Cells", + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Manufacturing", + "lighting_secondary_space_type": "Control Room", + "lighting_power_density": 0.5, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Sports Arena", + "lighting_secondary_space_type": "Court Sports Area", + "lighting_power_density": 2.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", + "lighting_secondary_space_type": "Courtroom", + "lighting_power_density": 1.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Manufacturing", + "lighting_secondary_space_type": "Detailed Manufacturing", + "lighting_power_density": 2.1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Emergency", + "lighting_power_density": 2.7, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Fire Stations", + "lighting_secondary_space_type": "Engine Room", + "lighting_power_density": 0.8, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Manufacturing", + "lighting_secondary_space_type": "Equipment Room", + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Exam/Treatment", + "lighting_power_density": 1.5, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Gymnasium/exercise Center", + "lighting_secondary_space_type": "Exercise Area", + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Religious Buildings", + "lighting_secondary_space_type": "Fellowship Hall", + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Warehouse", + "lighting_secondary_space_type": "Fine Material Storage", + "lighting_power_density": 1.4, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Automotive service/repair", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.7, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Bank/Office Banking Activity Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.5, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Convention Center exhibit Space", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Dormitory living Quarters", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hotel/motel Guest Rooms", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Parking Garage garage Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Post Office sorting Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Museum", + "lighting_secondary_space_type": "General Exhibition", + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Manufacturing", + "lighting_secondary_space_type": "High Bay (>25 ft Floor to Ceiling Height)", + "lighting_power_density": 1.7, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Sports Arena", + "lighting_secondary_space_type": "Indoor Playing Field Area", + "lighting_power_density": 1.4, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", + "lighting_secondary_space_type": "Judges Chambers", + "lighting_power_density": 1.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Laundry Washing", + "lighting_power_density": 0.6, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Manufacturing", + "lighting_secondary_space_type": "Low Bay (<25 ft Floor to Ceiling Height)", + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Mall Concourse", + "lighting_power_density": 1.7, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Medical Supply", + "lighting_power_density": 1.4, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Warehouse", + "lighting_secondary_space_type": "Medium/Bulky Material Storage", + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Nurse Station", + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Nursery", + "lighting_power_density": 0.6, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Operating Room", + "lighting_power_density": 2.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Patient Room", + "lighting_power_density": 0.7, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Pharmacy", + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Physical Therapy", + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Gymnasium/exercise Center", + "lighting_secondary_space_type": "Playing Area", + "lighting_power_density": 1.4, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Radiology", + "lighting_power_density": 0.4, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Library", + "lighting_secondary_space_type": "Reading Area", + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Recovery", + "lighting_power_density": 0.8, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Museum", + "lighting_secondary_space_type": "Restoration", + "lighting_power_density": 1.7, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Sports Arena", + "lighting_secondary_space_type": "Ring Sports Area", + "lighting_power_density": 2.7, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (Type 1)", + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (Type 2)", + "lighting_power_density": 1.7, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (Type 3)", + "lighting_power_density": 2.6, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (Type 4)", + "lighting_power_density": 4.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Area", + "lighting_power_density": 1.7, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Fire Stations", + "lighting_secondary_space_type": "Sleeping Quarters", + "lighting_power_density": 0.3, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Library", + "lighting_secondary_space_type": "Stacks", + "lighting_power_density": 1.7, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Transportation", + "lighting_secondary_space_type": "Terminal Ticket Counter", + "lighting_power_density": 1.5, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Religious Buildings", + "lighting_secondary_space_type": "Worship Pulpit, Choir", + "lighting_power_density": 2.4, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "None", + "lighting_secondary_space_type": "None", + "lighting_power_density": 0, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2010.csv b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2010.csv new file mode 100644 index 0000000000..025d0ceab6 --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2010.csv @@ -0,0 +1,134 @@ +method,lighting_primary_space_type,lighting_secondary_space_type,lighting_power_density,unit,rcr_threshold,automatic_daylight_responsive_controls_for_sidelighting,automatic_daylight_responsive_controls_for_toplighting,automatic_partial_off,automatic_full_off,scheduled_shutoff,annotation +BA,Automotive Facility,General,0.82,W/ft2,,REQ,REQ,,,, +BA,Convention Center,General,1.08,W/ft2,,REQ,REQ,,,, +BA,Courthouse,General,1.05,W/ft2,,REQ,REQ,,,, +BA,Dining: Bar Lounge/Leisure,General,0.99,W/ft2,,REQ,REQ,,,, +BA,Dining: Cafeteria/Fast Food,General,0.9,W/ft2,,REQ,REQ,,,, +BA,Dining: Family,General,0.89,W/ft2,,REQ,REQ,,,, +BA,Dormitory,General,0.61,W/ft2,,REQ,REQ,,,, +BA,Exercise Center,General,0.88,W/ft2,,REQ,REQ,,,, +BA,Fire Stations,General,0.71,W/ft2,,REQ,REQ,,,, +BA,Gymnasium,General,1,W/ft2,,REQ,REQ,,,, +BA,Health-care Clinic,General,0.87,W/ft2,,REQ,REQ,,,, +BA,Hospital,General,1.21,W/ft2,,REQ,REQ,,REQ,, +BA,Hotel,General,1,W/ft2,,REQ,REQ,,,, +BA,Library,General,1.18,W/ft2,,REQ,REQ,,,, +BA,Manufacturing Facility,General,1.11,W/ft2,,REQ,REQ,,,, +BA,Motel,General,0.88,W/ft2,,REQ,REQ,,,, +BA,Motion Picture Theater,General,0.83,W/ft2,,REQ,REQ,,,, +BA,Multifamily,General,0.6,W/ft2,,REQ,REQ,,,, +BA,Museum,General,1.06,W/ft2,,REQ,REQ,,,, +BA,Office,General,0.9,W/ft2,,REQ,REQ,,,, +BA,Parking Garage,General,0.25,W/ft2,,REQ,REQ,,,, +BA,Penitentiary,General,0.97,W/ft2,,REQ,REQ,,,, +BA,Performing Arts Theater,General,1.39,W/ft2,,REQ,REQ,,,, +BA,Police Station,General,0.96,W/ft2,,REQ,REQ,,,, +BA,Post Office,General,0.87,W/ft2,,REQ,REQ,,,, +BA,Religious Building,General,1.05,W/ft2,,REQ,REQ,,,, +BA,Retail,General,1.4,W/ft2,,REQ,REQ,,,, +BA,School/University,General,0.99,W/ft2,,REQ,REQ,,,, +BA,Sports Arena,General,0.78,W/ft2,,REQ,REQ,,,, +BA,Town Hall,General,0.92,W/ft2,,REQ,REQ,,,, +BA,Transportation,General,0.77,W/ft2,,REQ,REQ,,,, +BA,Warehouse,General,0.66,W/ft2,,REQ,REQ,,,, +BA,Workshop,General,1.2,W/ft2,,REQ,REQ,,,, +CS,Audience/seating Area permanent,For auditorium,0.79,W/ft2,6,REQ,REQ,,,, +CS,Office,Enclosed,1.1,W/ft2,8,REQ,REQ,,REQ,, +CS,Atrium,First 40 ft in height,0.03,W/ft,,REQ,REQ,,,, +CS,Dining Area,For Bar Lounge/Leisure Dining,1.31,W/ft2,4,REQ,REQ,,,, +CS,Laboratory,For Classrooms,1.28,W/ft2,6,REQ,REQ,,,, +CS,Lobby,For Elevator,0.64,W/ft2,6,REQ,REQ,,,, +CS,Dining Area,For Family Dining,0.89,W/ft2,4,REQ,REQ,,,, +CS,Laboratory,For Medical/Industrial/Research,1.81,W/ft2,6,REQ,REQ,,,, +CS,Lobby,For Motion Picture Theater,0.52,W/ft2,4,REQ,REQ,,,, +CS,Lobby,For Performing Arts Theater,2,W/ft2,6,REQ,REQ,,,, +CS,Audience/seating Area permanent,For Motion Picture Theater,1.14,W/ft2,4,REQ,REQ,,,, +CS,Classroom/Lecture/Training,General,1.24,W/ft2,4,REQ,REQ,,REQ,, +CS,Conference/Meeting/Multipurpose,General,1.23,W/ft2,6,REQ,REQ,,REQ,, +CS,Corridor/Transition,General,0.66,W/ft2,,REQ,REQ,,,,rcr_threshold: width<8 ft +CS,Dining Area,General,0.65,W/ft2,4,REQ,REQ,,,, +CS,Dressing/Fitting Room For Performing Arts Theater,General,0.4,W/ft2,6,REQ,REQ,,,, +CS,Electrical/Mechanical,General,0.95,W/ft2,6,REQ,REQ,,,, +CS,Food Preparation,General,0.99,W/ft2,6,REQ,REQ,,,, +CS,Lobby,General,0.9,W/ft2,4,REQ,REQ,,,, +CS,Locker Room,General,0.75,W/ft2,6,REQ,REQ,,REQ,, +CS,Lounge/Recreation,General,0.73,W/ft2,4,REQ,REQ,,REQ,, +CS,Restrooms,General,0.98,W/ft2,8,REQ,REQ,,REQ,, +CS,Sales Area,General,1.68,W/ft2,6,REQ,REQ,,,, +CS,Stairway,General,0.69,W/ft2,10,REQ,REQ,REQ,,, +CS,Storage,General,0.63,W/ft2,6,REQ,REQ,,REQ,, +CS,Workshop,General,1.59,W/ft2,6,REQ,REQ,,,, +CS,Atrium,Height above 40 ft,0.02,W/ft,,REQ,REQ,,,, +CS,Audience/seating Area permanent,For Performing Arts Theater,2.43,W/ft2,8,REQ,REQ,,,, +CS,Office,Open Plan,0.98,W/ft2,4,REQ,REQ,,,, +SS,Transportation,Air/Train/Bus Baggage Area,0.76,W/ft2,4,REQ,REQ,,,, +SS,Transportation,Airport Concourse,0.36,W/ft2,4,REQ,REQ,,,, +SS,Convention Center,Audience Seating,0.82,W/ft2,4,REQ,REQ,,,, +SS,Religious Buildings,Audience Seating,1.53,W/ft2,4,REQ,REQ,,,, +SS,Sports Arena,Audience Seating,0.43,W/ft2,4,REQ,REQ,,,, +SS,Transportation,Audience Seating,0.54,W/ft2,4,REQ,REQ,,,, +SS,Bank/Office,Banking Activity Area,1.38,W/ft2,6,REQ,REQ,,,, +SS,Library,Card File and Cataloging,0.72,W/ft2,4,REQ,REQ,,,, +SS,Courthouse/Police Station/Penitentiary,Confinement Cells,1.1,W/ft2,6,REQ,REQ,,,, +SS,Hospital,Corridor/Transition,0.89,W/ft2,,REQ,REQ,,,,rcr_threshold: width<8 ft +SS,Manufacturing,Corridor/Transition,0.41,W/ft2,,REQ,REQ,,,,rcr_threshold: width<8 ft +SS,Sports Arena,Court Sports Arena Class 1,3.01,W/ft2,4,REQ,REQ,,,, +SS,Sports Arena,Court Sports Arena Class 2,1.92,W/ft2,4,REQ,REQ,,,, +SS,Sports Arena,Court Sports Arena Class 3,1.2,W/ft2,4,REQ,REQ,,,, +SS,Sports Arena,Court Sports Arena Class 4,0.72,W/ft2,4,REQ,REQ,,,, +SS,Courthouse/Police Station/Penitentiary,Courtroom,1.72,W/ft2,6,REQ,REQ,,,, +SS,Manufacturing,Detailed Manufacturing,1.29,W/ft2,4,REQ,REQ,,,, +SS,Retail,Dressing/Fitting Room,0.87,W/ft2,8,REQ,REQ,,,, +SS,Hospital,Emergency,2.26,W/ft2,6,REQ,REQ,,,, +SS,Fire Stations,Engine Room,0.56,W/ft2,4,REQ,REQ,,,, +SS,Manufacturing,Equipment Room,0.95,W/ft2,6,REQ,REQ,,,, +SS,Hospital,Exam/Treatment,1.66,W/ft2,8,REQ,REQ,,,, +SS,Gymnasium/fitness Center,Exercise Area,0.72,W/ft2,4,REQ,REQ,,,, +SS,Convention Center,Exhibit Space,1.45,W/ft2,4,REQ,REQ,,,, +SS,Manufacturing,Extra High Bay (>50 ft Floor to Ceiling Height),1.05,W/ft2,4,REQ,REQ,,,, +SS,Religious Buildings,Fellowship Hall,0.64,W/ft2,4,REQ,REQ,,,, +SS,Warehouse,Fine Material Storage,0.95,W/ft2,6,REQ,REQ,,,, +SS,Parking Garage,Garage Area,0.19,W/ft2,4,REQ,REQ,,,, +SS,Post Office Sorting Area,General,0.94,W/ft2,4,REQ,REQ,,,, +SS,Museum,General Exhibition,1.05,W/ft2,6,REQ,REQ,,,, +SS,Gymnasium/fitness Center,Gymnasium Audience Seating,0.43,W/ft2,6,REQ,REQ,,,, +SS,Manufacturing,High Bay (25-50 ft Floor to Ceiling Height),1.23,W/ft2,4,REQ,REQ,,,, +SS,Hotel/Highway Lodging,Highway Lodging Dining,0.88,W/ft2,4,REQ,REQ,,,, +SS,Hotel/Highway Lodging,Highway Lodging Guest Rooms,0.75,W/ft2,6,REQ,REQ,,,, +SS,Hotel/Highway Lodging,Hotel Dining,0.82,W/ft2,4,REQ,REQ,,,, +SS,Hotel/Highway Lodging,Hotel Guest Rooms,1.11,W/ft2,6,REQ,REQ,,,, +SS,Hotel/Highway Lodging,Hotel Lobby,1.06,W/ft2,4,REQ,REQ,,,, +SS,Courthouse/Police Station/Penitentiary,Judges' Chambers,1.17,W/ft2,8,REQ,REQ,,,, +SS,Hospital,Laundry/Washing,0.6,W/ft2,4,REQ,REQ,,,, +SS,Dormitory,Living Quarters,0.38,W/ft2,8,REQ,REQ,,,, +SS,Hospital,Lounge/Recreation,1.07,W/ft2,6,REQ,REQ,,REQ,, +SS,Manufacturing,Low Bay (<25 ft Floor to Ceiling Height),1.19,W/ft2,4,REQ,REQ,,,, +SS,Retail,Mall Concourse,1.1,W/ft2,4,REQ,REQ,,,, +SS,Hospital,Medical Supply,1.27,W/ft2,6,REQ,REQ,,REQ,, +SS,Warehouse,Medium/Bulky Material Storage,0.58,W/ft2,4,REQ,REQ,,,, +SS,Hospital,Nursery,0.88,W/ft2,6,REQ,REQ,,,, +SS,Hospital,Nurses' Station,0.87,W/ft2,6,REQ,REQ,,,, +SS,Hospital,Operating Room,1.89,W/ft2,6,REQ,REQ,,,, +SS,Hospital,Patient Room,0.62,W/ft2,6,REQ,REQ,,,, +SS,Courthouse/Police Station/Penitentiary,Penitentiary Audience Seating,0.43,W/ft2,4,REQ,REQ,,,, +SS,Courthouse/Police Station/Penitentiary,Penitentiary Classroom,1.34,W/ft2,4,REQ,REQ,,REQ,, +SS,Courthouse/Police Station/Penitentiary,Penitentiary Dining,1.07,W/ft2,6,REQ,REQ,,,, +SS,Hospital,Pharmacy,1.14,W/ft2,6,REQ,REQ,,,, +SS,Hospital,Physical Therapy,0.91,W/ft2,6,REQ,REQ,,,, +SS,Gymnasium/fitness Center,Playing Area,1.2,W/ft2,4,REQ,REQ,,,, +SS,Hospital,Radiology/Imaging,1.32,W/ft2,6,REQ,REQ,,,, +SS,Library,Reading Area,0.93,W/ft2,4,REQ,REQ,,,, +SS,Hospital,Recovery,1.15,W/ft2,6,REQ,REQ,,,, +SS,Museum,Restoration,1.02,W/ft2,6,REQ,REQ,,,, +SS,Sports Arena,Ring Sports Area,2.68,W/ft2,4,REQ,REQ,,,, +SS,Retail,Sales Additional (Type 1),0.6,W/ft2,6,,REQ,,,, +SS,Retail,Sales Additional (Type 2),0.6,W/ft2,6,,REQ,,,, +SS,Retail,Sales Additional (Type 3),1.4,W/ft2,6,,REQ,,,, +SS,Retail,Sales Additional (Type 4),2.5,W/ft2,6,,REQ,,,, +SS,Retail,Sales Area,1.68,W/ft2,6,,REQ,,,, +SS,Automotive,Service/Repair,0.67,W/ft2,4,REQ,REQ,,,, +SS,Fire Stations,Sleeping Quarters,0.25,W/ft2,6,REQ,REQ,,,, +SS,Library,Stacks,1.71,W/ft2,4,REQ,REQ,,,, +SS,Transportation,Terminal Ticket Counter,1.08,W/ft2,4,REQ,REQ,,,, +SS,Religious Buildings,"Worship Pulpit, Choir",1.53,W/ft2,4,REQ,REQ,,,, +SS,None,None,0,W/ft2,,,,,,, diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2010.json b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2010.json new file mode 100644 index 0000000000..f3650018cd --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2010.json @@ -0,0 +1,1864 @@ +[ + { + "method": "BA", + "lighting_primary_space_type": "Automotive Facility", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.82, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Convention Center", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.08, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Courthouse", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.05, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Dining: Bar Lounge/Leisure", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.99, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Dining: Cafeteria/Fast Food", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Dining: Family", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.89, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Dormitory", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.61, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Exercise Center", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.88, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Fire Stations", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.71, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Gymnasium", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Health-care Clinic", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.87, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.21, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Hotel", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Library", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.18, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Manufacturing Facility", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.11, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Motel", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.88, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Motion Picture Theater", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.83, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Multifamily", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.6, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Museum", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.06, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Office", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Parking Garage", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.25, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Penitentiary", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.97, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Performing Arts Theater", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.39, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Police Station", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.96, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Post Office", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.87, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Religious Building", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.05, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.4, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "School/University", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.99, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Sports Arena", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.78, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Town Hall", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.92, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Transportation", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.77, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Warehouse", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.66, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Workshop", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience/seating Area permanent", + "lighting_secondary_space_type": "For auditorium", + "lighting_power_density": 0.79, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Office", + "lighting_secondary_space_type": "Enclosed", + "lighting_power_density": 1.1, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Atrium", + "lighting_secondary_space_type": "First 40 ft in height", + "lighting_power_density": 0.03, + "unit": "W/ft", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "For Bar Lounge/Leisure Dining", + "lighting_power_density": 1.31, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Laboratory", + "lighting_secondary_space_type": "For Classrooms", + "lighting_power_density": 1.28, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "For Elevator", + "lighting_power_density": 0.64, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "For Family Dining", + "lighting_power_density": 0.89, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Laboratory", + "lighting_secondary_space_type": "For Medical/Industrial/Research", + "lighting_power_density": 1.81, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "For Motion Picture Theater", + "lighting_power_density": 0.52, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "For Performing Arts Theater", + "lighting_power_density": 2, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience/seating Area permanent", + "lighting_secondary_space_type": "For Motion Picture Theater", + "lighting_power_density": 1.14, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Classroom/Lecture/Training", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.24, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Conference/Meeting/Multipurpose", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.23, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Corridor/Transition", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.66, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": "rcr_threshold: width<8 ft" + }, + { + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.65, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Dressing/Fitting Room For Performing Arts Theater", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.4, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Electrical/Mechanical", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.95, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Food Preparation", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.99, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Locker Room", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.75, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Lounge/Recreation", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.73, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Restrooms", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.98, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Sales Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.68, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Stairway", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.69, + "unit": "W/ft2", + "rcr_threshold": 10, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Storage", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.63, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Workshop", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.59, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Atrium", + "lighting_secondary_space_type": "Height above 40 ft", + "lighting_power_density": 0.02, + "unit": "W/ft", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience/seating Area permanent", + "lighting_secondary_space_type": "For Performing Arts Theater", + "lighting_power_density": 2.43, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Office", + "lighting_secondary_space_type": "Open Plan", + "lighting_power_density": 0.98, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Transportation", + "lighting_secondary_space_type": "Air/Train/Bus Baggage Area", + "lighting_power_density": 0.76, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Transportation", + "lighting_secondary_space_type": "Airport Concourse", + "lighting_power_density": 0.36, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Convention Center", + "lighting_secondary_space_type": "Audience Seating", + "lighting_power_density": 0.82, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Religious Buildings", + "lighting_secondary_space_type": "Audience Seating", + "lighting_power_density": 1.53, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Sports Arena", + "lighting_secondary_space_type": "Audience Seating", + "lighting_power_density": 0.43, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Transportation", + "lighting_secondary_space_type": "Audience Seating", + "lighting_power_density": 0.54, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Bank/Office", + "lighting_secondary_space_type": "Banking Activity Area", + "lighting_power_density": 1.38, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Library", + "lighting_secondary_space_type": "Card File and Cataloging", + "lighting_power_density": 0.72, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", + "lighting_secondary_space_type": "Confinement Cells", + "lighting_power_density": 1.1, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Corridor/Transition", + "lighting_power_density": 0.89, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": "rcr_threshold: width<8 ft" + }, + { + "method": "SS", + "lighting_primary_space_type": "Manufacturing", + "lighting_secondary_space_type": "Corridor/Transition", + "lighting_power_density": 0.41, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": "rcr_threshold: width<8 ft" + }, + { + "method": "SS", + "lighting_primary_space_type": "Sports Arena", + "lighting_secondary_space_type": "Court Sports Arena Class 1", + "lighting_power_density": 3.01, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Sports Arena", + "lighting_secondary_space_type": "Court Sports Arena Class 2", + "lighting_power_density": 1.92, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Sports Arena", + "lighting_secondary_space_type": "Court Sports Arena Class 3", + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Sports Arena", + "lighting_secondary_space_type": "Court Sports Arena Class 4", + "lighting_power_density": 0.72, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", + "lighting_secondary_space_type": "Courtroom", + "lighting_power_density": 1.72, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Manufacturing", + "lighting_secondary_space_type": "Detailed Manufacturing", + "lighting_power_density": 1.29, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Dressing/Fitting Room", + "lighting_power_density": 0.87, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Emergency", + "lighting_power_density": 2.26, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Fire Stations", + "lighting_secondary_space_type": "Engine Room", + "lighting_power_density": 0.56, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Manufacturing", + "lighting_secondary_space_type": "Equipment Room", + "lighting_power_density": 0.95, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Exam/Treatment", + "lighting_power_density": 1.66, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Gymnasium/fitness Center", + "lighting_secondary_space_type": "Exercise Area", + "lighting_power_density": 0.72, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Convention Center", + "lighting_secondary_space_type": "Exhibit Space", + "lighting_power_density": 1.45, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Manufacturing", + "lighting_secondary_space_type": "Extra High Bay (>50 ft Floor to Ceiling Height)", + "lighting_power_density": 1.05, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Religious Buildings", + "lighting_secondary_space_type": "Fellowship Hall", + "lighting_power_density": 0.64, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Warehouse", + "lighting_secondary_space_type": "Fine Material Storage", + "lighting_power_density": 0.95, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Parking Garage", + "lighting_secondary_space_type": "Garage Area", + "lighting_power_density": 0.19, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Post Office Sorting Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.94, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Museum", + "lighting_secondary_space_type": "General Exhibition", + "lighting_power_density": 1.05, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Gymnasium/fitness Center", + "lighting_secondary_space_type": "Gymnasium Audience Seating", + "lighting_power_density": 0.43, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Manufacturing", + "lighting_secondary_space_type": "High Bay (25-50 ft Floor to Ceiling Height)", + "lighting_power_density": 1.23, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hotel/Highway Lodging", + "lighting_secondary_space_type": "Highway Lodging Dining", + "lighting_power_density": 0.88, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hotel/Highway Lodging", + "lighting_secondary_space_type": "Highway Lodging Guest Rooms", + "lighting_power_density": 0.75, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hotel/Highway Lodging", + "lighting_secondary_space_type": "Hotel Dining", + "lighting_power_density": 0.82, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hotel/Highway Lodging", + "lighting_secondary_space_type": "Hotel Guest Rooms", + "lighting_power_density": 1.11, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hotel/Highway Lodging", + "lighting_secondary_space_type": "Hotel Lobby", + "lighting_power_density": 1.06, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", + "lighting_secondary_space_type": "Judges' Chambers", + "lighting_power_density": 1.17, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Laundry/Washing", + "lighting_power_density": 0.6, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Dormitory", + "lighting_secondary_space_type": "Living Quarters", + "lighting_power_density": 0.38, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Lounge/Recreation", + "lighting_power_density": 1.07, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Manufacturing", + "lighting_secondary_space_type": "Low Bay (<25 ft Floor to Ceiling Height)", + "lighting_power_density": 1.19, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Mall Concourse", + "lighting_power_density": 1.1, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Medical Supply", + "lighting_power_density": 1.27, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Warehouse", + "lighting_secondary_space_type": "Medium/Bulky Material Storage", + "lighting_power_density": 0.58, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Nursery", + "lighting_power_density": 0.88, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Nurses' Station", + "lighting_power_density": 0.87, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Operating Room", + "lighting_power_density": 1.89, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Patient Room", + "lighting_power_density": 0.62, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", + "lighting_secondary_space_type": "Penitentiary Audience Seating", + "lighting_power_density": 0.43, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", + "lighting_secondary_space_type": "Penitentiary Classroom", + "lighting_power_density": 1.34, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", + "lighting_secondary_space_type": "Penitentiary Dining", + "lighting_power_density": 1.07, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Pharmacy", + "lighting_power_density": 1.14, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Physical Therapy", + "lighting_power_density": 0.91, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Gymnasium/fitness Center", + "lighting_secondary_space_type": "Playing Area", + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Radiology/Imaging", + "lighting_power_density": 1.32, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Library", + "lighting_secondary_space_type": "Reading Area", + "lighting_power_density": 0.93, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Recovery", + "lighting_power_density": 1.15, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Museum", + "lighting_secondary_space_type": "Restoration", + "lighting_power_density": 1.02, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Sports Arena", + "lighting_secondary_space_type": "Ring Sports Area", + "lighting_power_density": 2.68, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (Type 1)", + "lighting_power_density": 0.6, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (Type 2)", + "lighting_power_density": 0.6, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (Type 3)", + "lighting_power_density": 1.4, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (Type 4)", + "lighting_power_density": 2.5, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Area", + "lighting_power_density": 1.68, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Automotive", + "lighting_secondary_space_type": "Service/Repair", + "lighting_power_density": 0.67, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Fire Stations", + "lighting_secondary_space_type": "Sleeping Quarters", + "lighting_power_density": 0.25, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Library", + "lighting_secondary_space_type": "Stacks", + "lighting_power_density": 1.71, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Transportation", + "lighting_secondary_space_type": "Terminal Ticket Counter", + "lighting_power_density": 1.08, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Religious Buildings", + "lighting_secondary_space_type": "Worship Pulpit, Choir", + "lighting_power_density": 1.53, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "None", + "lighting_secondary_space_type": "None", + "lighting_power_density": 0, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2013.csv b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2013.csv new file mode 100644 index 0000000000..f534ce6f32 --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2013.csv @@ -0,0 +1,144 @@ +method,lighting_primary_space_type,lighting_secondary_space_type,lighting_power_density,unit,rcr_threshold,automatic_daylight_responsive_controls_for_sidelighting,automatic_daylight_responsive_controls_for_toplighting,automatic_partial_off,automatic_full_off,scheduled_shutoff,annotation +BA,Automotive Facility,General,0.8,W/ft2,,,,,,, +BA,Convention Center,General,1.01,W/ft2,,,,,,, +BA,Courthouse,General,1.01,W/ft2,,,,,,, +BA,Dining: Bar Lounge/leisure,General,1.01,W/ft2,,,,,,, +BA,Dining: Cafeteria/fast Food,General,0.9,W/ft2,,,,,,, +BA,Dining: Family,General,0.95,W/ft2,,,,,,, +BA,Dormitory,General,0.57,W/ft2,,,,,,, +BA,Exercise Center,General,0.84,W/ft2,,,,,,, +BA,Fire Station,General,0.671,W/ft2,,,,,,, +BA,Gymnasium,General,0.94,W/ft2,,,,,,, +BA,Health-care Clinic,General,0.9,W/ft2,,,,,,, +BA,Hospital,General,1.05,W/ft2,,,,,,, +BA,Hotel/motel,General,0.87,W/ft2,,,,,,, +BA,Library,General,1.19,W/ft2,,,,,,, +BA,Manufacturing Facility,General,1.17,W/ft2,,,,,,, +BA,Motion Picture Theater,General,0.76,W/ft2,,,,,,, +BA,Multifamily,General,0.51,W/ft2,,,,,,, +BA,Museum,General,1.02,W/ft2,,,,,,, +BA,Office,General,0.82,W/ft2,,,,,,, +BA,Parking Garage,General,0.21,W/ft2,,,,,,, +BA,Penitentiary,General,0.81,W/ft2,,,,,,, +BA,Performing Arts Theater,General,1.39,W/ft2,,,,,,, +BA,Police Station,General,0.87,W/ft2,,,,,,, +BA,Post Office,General,0.87,W/ft2,,,,,,, +BA,Religious Building,General,1,W/ft2,,,,,,, +BA,Retail,General,1.26,W/ft2,,,,,,, +BA,School/University,General,0.87,W/ft2,,,,,,, +BA,Sports Arena,General,0.91,W/ft2,,,,,,, +BA,Town Hall,General,0.89,W/ft2,,,,,,, +BA,Transportation,General,0.7,W/ft2,,,,,,, +BA,Warehouse,General,0.66,W/ft2,,,,,,, +BA,Workshop,General,1.19,W/ft2,,,,,,, +CS,Atrium,<20 ft in height,0.03,W/ft,,REQ,REQ,,ADD2,ADD2,LP-Height +CS,Storage Room,<50 ft2,1.24,W/ft2,6,,,,ADD2,ADD2, +CS,Atrium,>40 ft in height,0.4,W/ft2,,REQ,REQ,,ADD2,ADD2,LP-Height; + 0.02W/ft +CS,Atrium,gt 20 ft and lt40 ft in height,0.03,W/ft,,REQ,REQ,,ADD2,ADD2,LP-Height +CS,Storage Room,gt 50 ft2 and lt 1000 ft2,0.63,W/ft2,6,REQ,REQ,,REQ,, +CS,Audience/seating Area,all other audience seating areas,0.43,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Classroom/Lecture Hall/Training Room,all other classrooms/lecture halls/training rooms,1.24,W/ft2,4,REQ,REQ,,REQ,, +CS,Corridor,all other corridors,0.66,W/ft2,,REQ,REQ,REQ,ADD2,ADD2,rcr_threshold: width<8 ft +CS,Dining Area,all other dining areas,0.65,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Laboratory,all other laboratories,1.81,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Lobby,all other lobbies,0.9,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, +CS,Lounge/Breakroom,all other lounges/breakrooms,0.73,W/ft2,4,REQ,REQ,,REQ,, +CS,Restroom,all other restrooms,0.98,W/ft2,8,REQ,REQ,,REQ,, +CS,Storage Room,all other storage rooms,0.63,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, +CS,Office,enclosed and >250 ft2,1.11,W/ft2,8,REQ,REQ,,ADD2,, +CS,Office,enclosed and lt 250 ft2,1.11,W/ft2,8,REQ,REQ,,REQ,, +CS,Lobby,for an elevator,0.64,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Audience/seating Area,in an auditorium,0.63,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Audience/seating Area,in a convention center,0.82,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,"Seating Area, General",General,0.54,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Audience/seating Area,in a gymnasium,0.65,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Audience/seating Area,in a motion picture theater,1.14,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Banking Activity Area,General,1.01,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Breakroom,General,0.73,W/ft2,4,REQ,REQ,,REQ,, +CS,Computer Room,General,1.71,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Conference/meeting/multipurpose Room,General,1.23,W/ft2,6,REQ,REQ,,REQ,, +CS,Confinement Cells,General,0.81,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Copy/Print Room,General,0.72,W/ft2,6,REQ,REQ,,REQ,, +CS,Courtroom,General,1.72,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Electrical/Mechanical Room,General,0.42,W/ft2,6,REQ,REQ,,,, +CS,Emergency Vehicle Garage,General,0.56,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Food Preparation Area,General,1.21,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Guest Room,General,0.91,W/ft2,6,,,,REQ,,See Section 9.4.1.3b +CS,Laundry/Washing Area,General,0.6,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,"Loading Dock, Interior",General,0.47,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Locker Room,General,0.75,W/ft2,6,REQ,REQ,,REQ,, +CS,"Parking Area, Interior",General,0.19,W/ft2,4,,,REQ,,,See Section 9.4.1.2 +CS,Pharmacy Area,General,1.68,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Sales Area,General,1.44,W/ft2,6,,REQ,,ADD2,ADD2, +CS,Audience/seating Area,in a penitentiary,0.28,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Stairway,General,0.69,W/ft2,10,REQ,REQ,REQ,ADD2,ADD2, +CS,Stairwell,General,0.69,W/ft2,10,REQ,REQ,REQ,ADD2,ADD2, +CS,Vehicular Maintenance Area,General,0.67,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Workshop,General,1.59,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Dining Area,in a facility for the visually impaired (and not used primarily by staff),2.65,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Corridor,in a facility for the visually impaired (and not used primarily by the staff),0.92,W/ft2,,REQ,REQ,REQ,ADD2,ADD2,rcr_threshold: width<8 ft +CS,Lobby,in a facility for the visually impaired (and not used primarily by the staff),1.8,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, +CS,Restroom,in a facility for the visually impaired (and not used primarily by the staff),1.21,W/ft2,8,REQ,REQ,,REQ,, +CS,Lounge/Breakroom,in a healthcare facility,0.92,W/ft2,6,REQ,REQ,,REQ,, +CS,Corridor,in a hospital,0.99,W/ft2,,REQ,REQ,ADD2,ADD2,ADD2,rcr_threshold: width<8 ft +CS,Lobby,in a hotel,1.06,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Corridor,in a manufacturing facility,0.41,W/ft2,,REQ,REQ,,ADD2,ADD2,rcr_threshold: width<8 ft +CS,Lobby,in a motion picture theater,0.59,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Audience/seating Area,in a performing arts theater,2.43,W/ft2,8,REQ,REQ,,ADD2,ADD2, +CS,Classroom/Lecture Hall/Training Room,in a penitentiary,1.34,W/ft2,4,REQ,REQ,,REQ,, +CS,Dining Area,in a penitentiary,0.96,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Lobby,in a performing arts theater,2,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, +CS,Dining Area,in bar/lounge or leisure dining,1.07,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Dining Area,in cafeteria or fast food dining,0.65,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Dining Area,in family dining,0.89,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Laboratory,in or as a classroom,1.43,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, +CS,Audience/seating Area,in a religious building,1.53,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Office,open plan,0.98,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Audience/seating Area,in a sports arena,0.43,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Religious Buildings,a worship/pulpit/choir area,1.53,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Transportation Facility,at a terminal ticket counter,0.8,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Sports Arena Playing Area,for a Class I facility,3.68,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Sports Arena Playing Area,for a Class II facility,2.4,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Sports Arena Playing Area,for a Class III facility,1.8,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Sports Arena Playing Area,for a Class IV facility,1.2,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Warehouse storage Area,"for medium to bulky, palletized items",0.58,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, +SS,Warehouse storage Area,"for smaller, hand-carried items",0.95,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, +SS,Automotive,General,0.67,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Convention Center Exhibit Space,General,1.45,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Dormitory Living Quarters,General,0.38,W/ft2,8,,,,,, +SS,Fire Station Sleeping Quarters,General,0.22,W/ft2,6,,,,,, +SS,Performing Arts Theater Dressing Room,General,0.61,W/ft2,6,REQ,REQ,,REQ,, +SS,Post Office Sorting Area,General,0.94,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, +SS,Transportation Facility,in a baggage/carousel area,0.53,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Facility For The Visually Impaired,in a chapel (used primarily by residents),2.21,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Manufacturing Facility,in a detailed manufacturing area,1.29,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Retail Facilities,in a dressing/fitting room,0.71,W/ft2,8,REQ,REQ,,REQ,, +SS,Religious Buildings,in a fellowship hall,0.64,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Museum,in a general exhibition area,1.05,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Manufacturing Facility,in a high bay area (25 50 ft floor-to-ceiling height),1.23,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Manufacturing Facility,in a low bay area (<25 ft floor-to-ceiling height),1.19,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Retail Facilities,in a mall concourse,1.1,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Healthcare Facility,in a medical supply room,0.74,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, +SS,Healthcare Facility,in a nurse s station,0.71,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Healthcare Facility,in a nursery,0.88,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Healthcare Facility,in a patient room,0.62,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Healthcare Facility,in a physical therapy room,0.91,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Gymnasium/fitness Center,in a playing area,1.2,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Library,in a reading area,1.06,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Healthcare Facility,in a recovery room,1.15,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Facility For The Visually Impaired,in a recreation room/common living room (and not used primarily by staff),2.41,W/ft2,6,,,,,, +SS,Facility For The Visually Impaired,in a recreation room/common living room (and not used primarily by staff),2.41,W/ft2,6,,,,,, +SS,Museum,in a restoration room,1.02,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Transportation Facility,in an airport concourse,0.36,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Manufacturing Facility,in an equipment room,0.74,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Healthcare Facility,in an exam/treatment room,1.66,W/ft2,8,REQ,REQ,,ADD2,ADD2, +SS,Gymnasium/fitness Center,in an exercise area,0.72,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Manufacturing Facility,in an extra high bay area (>50 ft floor-to-ceiling height),1.05,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Healthcare Facility,in an imaging room,1.51,W/ft2,6,,,,ADD2,ADD2, +SS,Healthcare Facility,in an operating room,2.48,W/ft2,6,,,,ADD2,ADD2, +SS,Library,in the stacks,1.71,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, +SS,Retail,Sales Additional (Type 1),0.6,W/ft2,4,REQ,REQ,,,, +SS,Retail,Sales Additional (Type 2),0.6,W/ft2,4,REQ,REQ,,,, +SS,Retail,Sales Additional (Type 3),1.4,W/ft2,4,REQ,REQ,,,, +SS,Retail,Sales Additional (Type 4),2.5,W/ft2,4,REQ,REQ,,,, +SS,None,None,0,W/ft2,,,,,,, diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2013.json b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2013.json new file mode 100644 index 0000000000..90fc41798d --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2013.json @@ -0,0 +1,2004 @@ +[ + { + "method": "BA", + "lighting_primary_space_type": "Automotive Facility", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.8, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Convention Center", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.01, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Courthouse", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.01, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Dining: Bar Lounge/leisure", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.01, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Dining: Cafeteria/fast Food", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Dining: Family", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.95, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Dormitory", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.57, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Exercise Center", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.84, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Fire Station", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.671, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Gymnasium", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.94, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Health-care Clinic", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.05, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Hotel/motel", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.87, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Library", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.19, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Manufacturing Facility", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.17, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Motion Picture Theater", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.76, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Multifamily", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.51, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Museum", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.02, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Office", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.82, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Parking Garage", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.21, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Penitentiary", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.81, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Performing Arts Theater", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.39, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Police Station", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.87, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Post Office", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.87, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Religious Building", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.26, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "School/University", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.87, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Sports Arena", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.91, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Town Hall", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.89, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Transportation", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.7, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Warehouse", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.66, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Workshop", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.19, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Atrium", + "lighting_secondary_space_type": "<20 ft in height", + "lighting_power_density": 0.03, + "unit": "W/ft", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": "LP-Height" + }, + { + "method": "CS", + "lighting_primary_space_type": "Storage Room", + "lighting_secondary_space_type": "<50 ft2", + "lighting_power_density": 1.24, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Atrium", + "lighting_secondary_space_type": ">40 ft in height", + "lighting_power_density": 0.4, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": "LP-Height; + 0.02W/ft" + }, + { + "method": "CS", + "lighting_primary_space_type": "Atrium", + "lighting_secondary_space_type": "gt 20 ft and lt40 ft in height", + "lighting_power_density": 0.03, + "unit": "W/ft", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": "LP-Height" + }, + { + "method": "CS", + "lighting_primary_space_type": "Storage Room", + "lighting_secondary_space_type": "gt 50 ft2 and lt 1000 ft2", + "lighting_power_density": 0.63, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "all other audience seating areas", + "lighting_power_density": 0.43, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Classroom/Lecture Hall/Training Room", + "lighting_secondary_space_type": "all other classrooms/lecture halls/training rooms", + "lighting_power_density": 1.24, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Corridor", + "lighting_secondary_space_type": "all other corridors", + "lighting_power_density": 0.66, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": "rcr_threshold: width<8 ft" + }, + { + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "all other dining areas", + "lighting_power_density": 0.65, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Laboratory", + "lighting_secondary_space_type": "all other laboratories", + "lighting_power_density": 1.81, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "all other lobbies", + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Lounge/Breakroom", + "lighting_secondary_space_type": "all other lounges/breakrooms", + "lighting_power_density": 0.73, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Restroom", + "lighting_secondary_space_type": "all other restrooms", + "lighting_power_density": 0.98, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Storage Room", + "lighting_secondary_space_type": "all other storage rooms", + "lighting_power_density": 0.63, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Office", + "lighting_secondary_space_type": "enclosed and >250 ft2", + "lighting_power_density": 1.11, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Office", + "lighting_secondary_space_type": "enclosed and lt 250 ft2", + "lighting_power_density": 1.11, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "for an elevator", + "lighting_power_density": 0.64, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "in an auditorium", + "lighting_power_density": 0.63, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "in a convention center", + "lighting_power_density": 0.82, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Seating Area, General", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.54, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "in a gymnasium", + "lighting_power_density": 0.65, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "in a motion picture theater", + "lighting_power_density": 1.14, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Banking Activity Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.01, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Breakroom", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.73, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Computer Room", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.71, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Conference/meeting/multipurpose Room", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.23, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Confinement Cells", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.81, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Copy/Print Room", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.72, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Courtroom", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.72, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Electrical/Mechanical Room", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.42, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Emergency Vehicle Garage", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.56, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Food Preparation Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.21, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Guest Room", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.91, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": "See Section 9.4.1.3b" + }, + { + "method": "CS", + "lighting_primary_space_type": "Laundry/Washing Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.6, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Loading Dock, Interior", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.47, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Locker Room", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.75, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Parking Area, Interior", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.19, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": "REQ", + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": "See Section 9.4.1.2" + }, + { + "method": "CS", + "lighting_primary_space_type": "Pharmacy Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.68, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Sales Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.44, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "in a penitentiary", + "lighting_power_density": 0.28, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Stairway", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.69, + "unit": "W/ft2", + "rcr_threshold": 10, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Stairwell", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.69, + "unit": "W/ft2", + "rcr_threshold": 10, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Vehicular Maintenance Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.67, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Workshop", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.59, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "in a facility for the visually impaired (and not used primarily by staff)", + "lighting_power_density": 2.65, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Corridor", + "lighting_secondary_space_type": "in a facility for the visually impaired (and not used primarily by the staff)", + "lighting_power_density": 0.92, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": "rcr_threshold: width<8 ft" + }, + { + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "in a facility for the visually impaired (and not used primarily by the staff)", + "lighting_power_density": 1.8, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Restroom", + "lighting_secondary_space_type": "in a facility for the visually impaired (and not used primarily by the staff)", + "lighting_power_density": 1.21, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Lounge/Breakroom", + "lighting_secondary_space_type": "in a healthcare facility", + "lighting_power_density": 0.92, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Corridor", + "lighting_secondary_space_type": "in a hospital", + "lighting_power_density": 0.99, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "ADD2", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": "rcr_threshold: width<8 ft" + }, + { + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "in a hotel", + "lighting_power_density": 1.06, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Corridor", + "lighting_secondary_space_type": "in a manufacturing facility", + "lighting_power_density": 0.41, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": "rcr_threshold: width<8 ft" + }, + { + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "in a motion picture theater", + "lighting_power_density": 0.59, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "in a performing arts theater", + "lighting_power_density": 2.43, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Classroom/Lecture Hall/Training Room", + "lighting_secondary_space_type": "in a penitentiary", + "lighting_power_density": 1.34, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "in a penitentiary", + "lighting_power_density": 0.96, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "in a performing arts theater", + "lighting_power_density": 2, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "in bar/lounge or leisure dining", + "lighting_power_density": 1.07, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "in cafeteria or fast food dining", + "lighting_power_density": 0.65, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "in family dining", + "lighting_power_density": 0.89, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Laboratory", + "lighting_secondary_space_type": "in or as a classroom", + "lighting_power_density": 1.43, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "in a religious building", + "lighting_power_density": 1.53, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Office", + "lighting_secondary_space_type": "open plan", + "lighting_power_density": 0.98, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "in a sports arena", + "lighting_power_density": 0.43, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Religious Buildings", + "lighting_secondary_space_type": "a worship/pulpit/choir area", + "lighting_power_density": 1.53, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Transportation Facility", + "lighting_secondary_space_type": "at a terminal ticket counter", + "lighting_power_density": 0.8, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Sports Arena Playing Area", + "lighting_secondary_space_type": "for a Class I facility", + "lighting_power_density": 3.68, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Sports Arena Playing Area", + "lighting_secondary_space_type": "for a Class II facility", + "lighting_power_density": 2.4, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Sports Arena Playing Area", + "lighting_secondary_space_type": "for a Class III facility", + "lighting_power_density": 1.8, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Sports Arena Playing Area", + "lighting_secondary_space_type": "for a Class IV facility", + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Warehouse storage Area", + "lighting_secondary_space_type": "for medium to bulky, palletized items", + "lighting_power_density": 0.58, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Warehouse storage Area", + "lighting_secondary_space_type": "for smaller, hand-carried items", + "lighting_power_density": 0.95, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Automotive", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.67, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Convention Center Exhibit Space", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.45, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Dormitory Living Quarters", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.38, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Fire Station Sleeping Quarters", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.22, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Performing Arts Theater Dressing Room", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.61, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Post Office Sorting Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.94, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Transportation Facility", + "lighting_secondary_space_type": "in a baggage/carousel area", + "lighting_power_density": 0.53, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Facility For The Visually Impaired", + "lighting_secondary_space_type": "in a chapel (used primarily by residents)", + "lighting_power_density": 2.21, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Manufacturing Facility", + "lighting_secondary_space_type": "in a detailed manufacturing area", + "lighting_power_density": 1.29, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Retail Facilities", + "lighting_secondary_space_type": "in a dressing/fitting room", + "lighting_power_density": 0.71, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Religious Buildings", + "lighting_secondary_space_type": "in a fellowship hall", + "lighting_power_density": 0.64, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Museum", + "lighting_secondary_space_type": "in a general exhibition area", + "lighting_power_density": 1.05, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Manufacturing Facility", + "lighting_secondary_space_type": "in a high bay area (25 50 ft floor-to-ceiling height)", + "lighting_power_density": 1.23, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Manufacturing Facility", + "lighting_secondary_space_type": "in a low bay area (<25 ft floor-to-ceiling height)", + "lighting_power_density": 1.19, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Retail Facilities", + "lighting_secondary_space_type": "in a mall concourse", + "lighting_power_density": 1.1, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "in a medical supply room", + "lighting_power_density": 0.74, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "in a nurse s station", + "lighting_power_density": 0.71, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "in a nursery", + "lighting_power_density": 0.88, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "in a patient room", + "lighting_power_density": 0.62, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "in a physical therapy room", + "lighting_power_density": 0.91, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Gymnasium/fitness Center", + "lighting_secondary_space_type": "in a playing area", + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Library", + "lighting_secondary_space_type": "in a reading area", + "lighting_power_density": 1.06, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "in a recovery room", + "lighting_power_density": 1.15, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Facility For The Visually Impaired", + "lighting_secondary_space_type": "in a recreation room/common living room (and not used primarily by staff)", + "lighting_power_density": 2.41, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Facility For The Visually Impaired", + "lighting_secondary_space_type": "in a recreation room/common living room (and not used primarily by staff)", + "lighting_power_density": 2.41, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Museum", + "lighting_secondary_space_type": "in a restoration room", + "lighting_power_density": 1.02, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Transportation Facility", + "lighting_secondary_space_type": "in an airport concourse", + "lighting_power_density": 0.36, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Manufacturing Facility", + "lighting_secondary_space_type": "in an equipment room", + "lighting_power_density": 0.74, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "in an exam/treatment room", + "lighting_power_density": 1.66, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Gymnasium/fitness Center", + "lighting_secondary_space_type": "in an exercise area", + "lighting_power_density": 0.72, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Manufacturing Facility", + "lighting_secondary_space_type": "in an extra high bay area (>50 ft floor-to-ceiling height)", + "lighting_power_density": 1.05, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "in an imaging room", + "lighting_power_density": 1.51, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "in an operating room", + "lighting_power_density": 2.48, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Library", + "lighting_secondary_space_type": "in the stacks", + "lighting_power_density": 1.71, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (Type 1)", + "lighting_power_density": 0.6, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (Type 2)", + "lighting_power_density": 0.6, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (Type 3)", + "lighting_power_density": 1.4, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (Type 4)", + "lighting_power_density": 2.5, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "None", + "lighting_secondary_space_type": "None", + "lighting_power_density": 0, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.csv b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.csv new file mode 100644 index 0000000000..931c281a64 --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.csv @@ -0,0 +1,143 @@ +method,lighting_primary_space_type,lighting_secondary_space_type,lighting_power_density,unit,rcr_threshold,automatic_daylight_responsive_controls_for_sidelighting,automatic_daylight_responsive_controls_for_toplighting,automatic_partial_off,automatic_full_off,scheduled_shutoff,annotation +BA,Automotive Facility,General,0.71,W/ft2,,,,,,, +BA,Convention Center,General,0.76,W/ft2,,,,,,, +BA,Courthouse,General,0.9,W/ft2,,,,,,, +BA,Dining: Bar Lounge/leisure,General,0.9,W/ft2,,,,,,, +BA,Dining: Cafeteria/Fast Food,General,0.79,W/ft2,,,,,,, +BA,Dining: Family,General,0.78,W/ft2,,,,,,, +BA,Dormitory,General,0.61,W/ft2,,,,,,, +BA,Exercise Center,General,0.65,W/ft2,,,,,,, +BA,Fire Station,General,0.53,W/ft2,,,,,,, +BA,Gymnasium,General,0.68,W/ft2,,,,,,, +BA,Health-care Clinic,General,0.82,W/ft2,,,,,,, +BA,Hospital,General,1.05,W/ft2,,,,,,, +BA,Hotel/motel,General,0.75,W/ft2,,,,,,, +BA,Library,General,0.78,W/ft2,,,,,,, +BA,Manufacturing Facility,General,0.9,W/ft2,,,,,,, +BA,Motion Picture Theater,General,0.83,W/ft2,,,,,,, +BA,Multifamily,General,0.68,W/ft2,,,,,,, +BA,Museum,General,1.06,W/ft2,,,,,,, +BA,Office,General,0.79,W/ft2,,,,,,, +BA,Parking Garage,General,0.15,W/ft2,,,,,,, +BA,Penitentiary,General,0.75,W/ft2,,,,,,, +BA,Performing Arts Theater,General,1.18,W/ft2,,,,,,, +BA,Police Station,General,0.8,W/ft2,,,,,,, +BA,Post Office,General,0.67,W/ft2,,,,,,, +BA,Religious Facility,General,0.94,W/ft2,,,,,,, +BA,Retail,General,1.06,W/ft2,,,,,,, +BA,School/University,General,0.81,W/ft2,,,,,,, +BA,Sports Arena,General,0.87,W/ft2,,,,,,, +BA,Town Hall,General,0.8,W/ft2,,,,,,, +BA,Transportation,General,0.61,W/ft2,,,,,,, +BA,Warehouse,General,0.48,W/ft2,,,,,,, +BA,Workshop,General,0.9,W/ft2,,,,,,, +CS,Atrium,<20 ft in height,0.03,W/ft,,REQ,REQ,,ADD2,ADD2, +CS,Storage Room,<50 Ft2,0.97,W/ft2,6,,,,ADD2,ADD2, +CS,Atrium,>40 ft in height,0.4,W/ft2,,REQ,REQ,,ADD2,ADD2, +CS,Atrium,gt 20 ft and lt 40 ft in height,0.03,W/ft,,REQ,REQ,,ADD2,ADD2, +CS,Storage Room,gt 50 Ft2 And lt 1000 Ft2,0.46,W/ft2,6,REQ,REQ,,REQ,, +CS,Audience Seating Area,All Other Audience Seating Areas,0.43,W/ft2,4,,REQ,REQ,,ADD2,ADD2 +CS,Classroom/lecture Hall/training Room,All Other Classrooms/lecture Halls/training Rooms,0.92,W/ft2,4,REQ,REQ,,REQ,, +CS,Corridor,All Other Corridors,0.66,W/ft2,,REQ,REQ,REQ,ADD2,ADD2,rcr_threshold: width<8 ft +CS,Dining Area,All Other Dining Areas,0.63,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Laboratory,All Other Laboratories,1.45,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Lobby,All Other Lobbies,1,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, +CS,Lounge/Breakroom,All Other Lounges/breakrooms,0.62,W/ft2,4,REQ,REQ,,REQ,, +CS,Restroom,All Other Restrooms,0.85,W/ft2,8,REQ,REQ,,REQ,, +CS,Storage Room,All Other Storage Rooms,0.46,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, +CS,Audience Seating Area,Auditorium,0.63,W/ft2,6,,REQ,REQ,,ADD2,ADD2 +CS,Dining Area,Bar/lounge Or Leisure Dining,0.93,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Dining Area,Cafeteria Or Fast Food Dining,0.63,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Lobby,Elevator,0.69,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Office,Enclosed And >250 Ft2,0.93,W/ft2,8,REQ,REQ,,ADD2,ADD2, +CS,Office,Enclosed And gt 250 Ft2,0.93,W/ft2,8,REQ,REQ,,REQ,, +CS,Dining Area,Facility For The Visually Impaired (and Not Used Primarily By Staff),2,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Corridor,Facility For The Visually Impaired (and Not Used Primarily By The Staff),0.92,W/ft2,,REQ,REQ,REQ,ADD2,ADD2, +CS,Lobby,Facility For The Visually Impaired (and Not Used Primarily By The Staff),2.03,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Restroom,Facility For The Visually Impaired (and Not Used Primarily By The Staff),0.96,W/ft2,8,REQ,REQ,,REQ,, +CS,Dining Area,Family Dining,0.71,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Audience Seating Area,Convention Center,0.82,W/ft2,4,,REQ,REQ,,ADD2,ADD2 +CS,"Seating Area, General",General,0.42,W/ft2,4,,REQ,REQ,,ADD2,ADD2 +CS,Audience Seating Area,Gymnasium,0.65,W/ft2,6,,REQ,REQ,,ADD2,ADD2 +CS,Audience Seating Area,Motion Picture Theater,1.14,W/ft2,4,,REQ,REQ,,ADD2,ADD2 +CS,Banking Activity Area,General,0.86,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Breakroom,General,0.62,W/ft2,4,REQ,REQ,REQ,,, +CS,Computer Room,General,1.33,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Conference/meeting/multipurpose Room,General,1.07,W/ft2,6,REQ,REQ,,REQ,, +CS,Confinement Cells,General,0.81,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Copy/Print Room,General,0.56,W/ft2,6,REQ,REQ,,REQ,, +CS,Courtroom,General,1.39,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Electrical/mechanical Room,General,0.43,W/ft2,6,REQ,REQ,,,, +CS,Emergency Vehicle Garage,General,0.41,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Food Preparation Area,General,1.06,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Guest Room,General,0.77,W/ft2,6,,,,,,See section 9.4.1.3(b) +CS,Laundry/washing Area,General,0.43,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,"Loading Dock, Interior",General,0.58,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Locker Room,General,0.48,W/ft2,6,REQ,REQ,,REQ,, +CS,"Parking Area, Interior",General,0.14,W/ft2,4,,,,,,See Section 9.4.1.2 +CS,Pharmacy Area,General,1.34,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Sales Area,General,1.22,W/ft2,3,,REQ,,ADD2,ADD2, +CS,Stairway,General,0.58,W/ft2,10,REQ,REQ,REQ,ADD2,ADD2, +CS,Stairwell,General,0.58,W/ft2,10,REQ,REQ,REQ,ADD2,ADD2, +CS,Vehicular Maintenance Area,General,0.56,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Workshop,General,1.14,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Audience Seating Area,Penitentiary,0.28,W/ft2,4,,REQ,REQ,,ADD2,ADD2 +CS,Lounge/Breakroom,Healthcare Facility,0.78,W/ft2,6,REQ,REQ,,REQ,, +CS,Corridor,Hospital,0.92,W/ft2,,REQ,REQ,ADD2,ADD2,ADD2, +CS,Lobby,Hotel,1.06,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Audience Seating Area,Performing Arts Theater,2.03,W/ft2,8,,REQ,REQ,,ADD2,ADD2 +CS,Laboratory,In Or As A Classroom,1.2,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, +CS,Corridor,Manufacturing Facility,0.29,W/ft2,,REQ,REQ,,ADD2,ADD2, +CS,Audience Seating Area,Religious Facility,1.53,W/ft2,4,,REQ,REQ,,ADD2,ADD2 +CS,Lobby,Motion Picture Theater,0.45,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Office,Open Plan,0.81,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Classroom/lecture Hall/training Room,Penitentiary,1.34,W/ft2,4,REQ,REQ,,REQ,, +CS,Dining Area,Penitentiary,0.96,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Lobby,Performing Arts Theater,1.7,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, +CS,Audience Seating Area,Sports Arena,0.43,W/ft2,4,,REQ,REQ,,ADD2,ADD2 +SS,Transportation Facility,Airport Concourse,0.31,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Transportation Facility,Baggage/carousel Area,0.46,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Facility For The Visually Impaired,Chapel (used Primarily By Residents),1.06,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Sports Arena—playing Area,Class I Facility,2.47,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Sports Arena—playing Area,Class II Facility,1.96,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Sports Arena—playing Area,Class Iii Facility,1.7,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Sports Arena—playing Area,Class Iv Facility,1.13,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Manufacturing Facility,Detailed Manufacturing Area,0.93,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Retail Facilities,Dressing/Fitting Room,0.5,W/ft2,8,,REQ,,REQ,, +SS,Manufacturing Facility,Equipment Room,0.65,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Healthcare Facility,Exam/treatment Room,1.68,W/ft2,8,REQ,REQ,,ADD2,ADD2, +SS,Gymnasium/fitness Center,Exercise Area,0.5,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Manufacturing Facility,Extra High Bay Area (>50 Ft Floor-to-ceiling Height),1.05,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Religious Facility,Fellowship Hall,0.55,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Automotive,General,0.56,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Convention Center—exhibit Space,General,0.88,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Dormitory—living Quarters,General,0.54,W/ft2,8,,,,,, +SS,Fire Station—sleeping Quarters,General,0.2,W/ft2,6,,,,,, +SS,Performing Arts Theater—dressing Room,General,0.36,W/ft2,6,REQ,REQ,,REQ,, +SS,Post Office—sorting Area,General,0.68,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, +SS,Museum,General Exhibition Area,1.05,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Manufacturing Facility,High Bay Area (25 To 50 Ft Floor-to-ceiling Height),0.75,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Healthcare Facility,Imaging Room,1.06,W/ft2,6,,,,ADD2,ADD2, +SS,Manufacturing Facility,Low Bay Area (<25 Ft Floor-to-ceiling Height),0.96,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Retail Facilities,Mall Concourse,0.9,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Healthcare Facility,Medical Supply Room,0.54,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, +SS,Warehouse—storage Area,"Medium To Bulky, Palletized Items",0.35,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, +SS,Healthcare Facility,Nurse’s Station,0.81,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Healthcare Facility,Nursery,1,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Healthcare Facility,Operating Room,2.17,W/ft2,6,,,,ADD2,ADD2, +SS,Healthcare Facility,Patient Room,0.62,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Healthcare Facility,Physical Therapy Room,0.84,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Gymnasium/fitness Center,Playing Area,0.82,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Library,Reading Area,0.82,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Healthcare Facility,Recovery Room,1.03,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Facility For The Visually Impaired,Recreation Room/common Living Room (and Not Used Primarily By Staff),1.8,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Museum,Restoration Room,0.85,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Retail,Sales Additional (type 1),0.45,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Retail,Sales Additional (type 2),0.45,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Retail,Sales Additional (type 3),1.05,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Retail,Sales Additional (type 4),1.88,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Warehouse—storage Area,"Smaller, Hand-carried Items",0.69,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, +SS,Library,Stacks,1.2,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, +SS,Transportation Facility,Terminal Ticket Counter,0.62,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Religious Facility,Worship/Pulpit/Choir Area,1.53,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,None,None,0,W/ft2,,,,,,, diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.json b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.json new file mode 100644 index 0000000000..dac50ddbe7 --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.json @@ -0,0 +1,1990 @@ +[ + { + "method": "BA", + "lighting_primary_space_type": "Automotive Facility", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.71, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Convention Center", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.76, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Courthouse", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Dining: Bar Lounge/leisure", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Dining: Cafeteria/Fast Food", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.79, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Dining: Family", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.78, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Dormitory", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.61, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Exercise Center", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.65, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Fire Station", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.53, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Gymnasium", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.68, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Health-care Clinic", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.82, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.05, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Hotel/motel", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.75, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Library", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.78, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Manufacturing Facility", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Motion Picture Theater", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.83, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Multifamily", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.68, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Museum", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.06, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Office", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.79, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Parking Garage", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.15, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Penitentiary", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.75, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Performing Arts Theater", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.18, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Police Station", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.8, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Post Office", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.67, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Religious Facility", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.94, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.06, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "School/University", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.81, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Sports Arena", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.87, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Town Hall", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.8, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Transportation", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.61, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Warehouse", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.48, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "BA", + "lighting_primary_space_type": "Workshop", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Atrium", + "lighting_secondary_space_type": "<20 ft in height", + "lighting_power_density": 0.03, + "unit": "W/ft", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Storage Room", + "lighting_secondary_space_type": "<50 Ft2", + "lighting_power_density": 0.97, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Atrium", + "lighting_secondary_space_type": ">40 ft in height", + "lighting_power_density": 0.4, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Atrium", + "lighting_secondary_space_type": "gt 20 ft and lt 40 ft in height", + "lighting_power_density": 0.03, + "unit": "W/ft", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Storage Room", + "lighting_secondary_space_type": "gt 50 Ft2 And lt 1000 Ft2", + "lighting_power_density": 0.46, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience Seating Area", + "lighting_secondary_space_type": "All Other Audience Seating Areas", + "lighting_power_density": 0.43, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": null, + "scheduled_shutoff": "ADD2", + "annotation": "ADD2" + }, + { + "method": "CS", + "lighting_primary_space_type": "Classroom/lecture Hall/training Room", + "lighting_secondary_space_type": "All Other Classrooms/lecture Halls/training Rooms", + "lighting_power_density": 0.92, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Corridor", + "lighting_secondary_space_type": "All Other Corridors", + "lighting_power_density": 0.66, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": "rcr_threshold: width<8 ft" + }, + { + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "All Other Dining Areas", + "lighting_power_density": 0.63, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Laboratory", + "lighting_secondary_space_type": "All Other Laboratories", + "lighting_power_density": 1.45, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "All Other Lobbies", + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Lounge/Breakroom", + "lighting_secondary_space_type": "All Other Lounges/breakrooms", + "lighting_power_density": 0.62, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Restroom", + "lighting_secondary_space_type": "All Other Restrooms", + "lighting_power_density": 0.85, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Storage Room", + "lighting_secondary_space_type": "All Other Storage Rooms", + "lighting_power_density": 0.46, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience Seating Area", + "lighting_secondary_space_type": "Auditorium", + "lighting_power_density": 0.63, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": null, + "scheduled_shutoff": "ADD2", + "annotation": "ADD2" + }, + { + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "Bar/lounge Or Leisure Dining", + "lighting_power_density": 0.93, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "Cafeteria Or Fast Food Dining", + "lighting_power_density": 0.63, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "Elevator", + "lighting_power_density": 0.69, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Office", + "lighting_secondary_space_type": "Enclosed And >250 Ft2", + "lighting_power_density": 0.93, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Office", + "lighting_secondary_space_type": "Enclosed And gt 250 Ft2", + "lighting_power_density": 0.93, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "Facility For The Visually Impaired (and Not Used Primarily By Staff)", + "lighting_power_density": 2, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Corridor", + "lighting_secondary_space_type": "Facility For The Visually Impaired (and Not Used Primarily By The Staff)", + "lighting_power_density": 0.92, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "Facility For The Visually Impaired (and Not Used Primarily By The Staff)", + "lighting_power_density": 2.03, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Restroom", + "lighting_secondary_space_type": "Facility For The Visually Impaired (and Not Used Primarily By The Staff)", + "lighting_power_density": 0.96, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "Family Dining", + "lighting_power_density": 0.71, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience Seating Area", + "lighting_secondary_space_type": "Convention Center", + "lighting_power_density": 0.82, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": null, + "scheduled_shutoff": "ADD2", + "annotation": "ADD2" + }, + { + "method": "CS", + "lighting_primary_space_type": "Seating Area, General", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.42, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": null, + "scheduled_shutoff": "ADD2", + "annotation": "ADD2" + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience Seating Area", + "lighting_secondary_space_type": "Gymnasium", + "lighting_power_density": 0.65, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": null, + "scheduled_shutoff": "ADD2", + "annotation": "ADD2" + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience Seating Area", + "lighting_secondary_space_type": "Motion Picture Theater", + "lighting_power_density": 1.14, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": null, + "scheduled_shutoff": "ADD2", + "annotation": "ADD2" + }, + { + "method": "CS", + "lighting_primary_space_type": "Banking Activity Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.86, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Breakroom", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.62, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Computer Room", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.33, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Conference/meeting/multipurpose Room", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.07, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Confinement Cells", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.81, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Copy/Print Room", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.56, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Courtroom", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.39, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Electrical/mechanical Room", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.43, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Emergency Vehicle Garage", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.41, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Food Preparation Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.06, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Guest Room", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.77, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": "See section 9.4.1.3(b)" + }, + { + "method": "CS", + "lighting_primary_space_type": "Laundry/washing Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.43, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Loading Dock, Interior", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.58, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Locker Room", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.48, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Parking Area, Interior", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.14, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": "See Section 9.4.1.2" + }, + { + "method": "CS", + "lighting_primary_space_type": "Pharmacy Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.34, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Sales Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.22, + "unit": "W/ft2", + "rcr_threshold": 3, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Stairway", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.58, + "unit": "W/ft2", + "rcr_threshold": 10, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Stairwell", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.58, + "unit": "W/ft2", + "rcr_threshold": 10, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Vehicular Maintenance Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.56, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Workshop", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.14, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience Seating Area", + "lighting_secondary_space_type": "Penitentiary", + "lighting_power_density": 0.28, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": null, + "scheduled_shutoff": "ADD2", + "annotation": "ADD2" + }, + { + "method": "CS", + "lighting_primary_space_type": "Lounge/Breakroom", + "lighting_secondary_space_type": "Healthcare Facility", + "lighting_power_density": 0.78, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Corridor", + "lighting_secondary_space_type": "Hospital", + "lighting_power_density": 0.92, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "ADD2", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "Hotel", + "lighting_power_density": 1.06, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience Seating Area", + "lighting_secondary_space_type": "Performing Arts Theater", + "lighting_power_density": 2.03, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": null, + "scheduled_shutoff": "ADD2", + "annotation": "ADD2" + }, + { + "method": "CS", + "lighting_primary_space_type": "Laboratory", + "lighting_secondary_space_type": "In Or As A Classroom", + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Corridor", + "lighting_secondary_space_type": "Manufacturing Facility", + "lighting_power_density": 0.29, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience Seating Area", + "lighting_secondary_space_type": "Religious Facility", + "lighting_power_density": 1.53, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": null, + "scheduled_shutoff": "ADD2", + "annotation": "ADD2" + }, + { + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "Motion Picture Theater", + "lighting_power_density": 0.45, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Office", + "lighting_secondary_space_type": "Open Plan", + "lighting_power_density": 0.81, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Classroom/lecture Hall/training Room", + "lighting_secondary_space_type": "Penitentiary", + "lighting_power_density": 1.34, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "Penitentiary", + "lighting_power_density": 0.96, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "Performing Arts Theater", + "lighting_power_density": 1.7, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Audience Seating Area", + "lighting_secondary_space_type": "Sports Arena", + "lighting_power_density": 0.43, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": null, + "scheduled_shutoff": "ADD2", + "annotation": "ADD2" + }, + { + "method": "SS", + "lighting_primary_space_type": "Transportation Facility", + "lighting_secondary_space_type": "Airport Concourse", + "lighting_power_density": 0.31, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Transportation Facility", + "lighting_secondary_space_type": "Baggage/carousel Area", + "lighting_power_density": 0.46, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Facility For The Visually Impaired", + "lighting_secondary_space_type": "Chapel (used Primarily By Residents)", + "lighting_power_density": 1.06, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Sports Arena\u00e2\u20ac\u201dplaying Area", + "lighting_secondary_space_type": "Class I Facility", + "lighting_power_density": 2.47, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Sports Arena\u00e2\u20ac\u201dplaying Area", + "lighting_secondary_space_type": "Class II Facility", + "lighting_power_density": 1.96, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Sports Arena\u00e2\u20ac\u201dplaying Area", + "lighting_secondary_space_type": "Class Iii Facility", + "lighting_power_density": 1.7, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Sports Arena\u00e2\u20ac\u201dplaying Area", + "lighting_secondary_space_type": "Class Iv Facility", + "lighting_power_density": 1.13, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Manufacturing Facility", + "lighting_secondary_space_type": "Detailed Manufacturing Area", + "lighting_power_density": 0.93, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Retail Facilities", + "lighting_secondary_space_type": "Dressing/Fitting Room", + "lighting_power_density": 0.5, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Manufacturing Facility", + "lighting_secondary_space_type": "Equipment Room", + "lighting_power_density": 0.65, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "Exam/treatment Room", + "lighting_power_density": 1.68, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Gymnasium/fitness Center", + "lighting_secondary_space_type": "Exercise Area", + "lighting_power_density": 0.5, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Manufacturing Facility", + "lighting_secondary_space_type": "Extra High Bay Area (>50 Ft Floor-to-ceiling Height)", + "lighting_power_density": 1.05, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Religious Facility", + "lighting_secondary_space_type": "Fellowship Hall", + "lighting_power_density": 0.55, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Automotive", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.56, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Convention Center\u00e2\u20ac\u201dexhibit Space", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.88, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Dormitory\u00e2\u20ac\u201dliving Quarters", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.54, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Fire Station\u00e2\u20ac\u201dsleeping Quarters", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.2, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Performing Arts Theater\u00e2\u20ac\u201ddressing Room", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.36, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Post Office\u00e2\u20ac\u201dsorting Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.68, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Museum", + "lighting_secondary_space_type": "General Exhibition Area", + "lighting_power_density": 1.05, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Manufacturing Facility", + "lighting_secondary_space_type": "High Bay Area (25 To 50 Ft Floor-to-ceiling Height)", + "lighting_power_density": 0.75, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "Imaging Room", + "lighting_power_density": 1.06, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Manufacturing Facility", + "lighting_secondary_space_type": "Low Bay Area (<25 Ft Floor-to-ceiling Height)", + "lighting_power_density": 0.96, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Retail Facilities", + "lighting_secondary_space_type": "Mall Concourse", + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "Medical Supply Room", + "lighting_power_density": 0.54, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Warehouse\u00e2\u20ac\u201dstorage Area", + "lighting_secondary_space_type": "Medium To Bulky, Palletized Items", + "lighting_power_density": 0.35, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "Nurse\u00e2\u20ac\u2122s Station", + "lighting_power_density": 0.81, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "Nursery", + "lighting_power_density": 1, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "Operating Room", + "lighting_power_density": 2.17, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "Patient Room", + "lighting_power_density": 0.62, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "Physical Therapy Room", + "lighting_power_density": 0.84, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Gymnasium/fitness Center", + "lighting_secondary_space_type": "Playing Area", + "lighting_power_density": 0.82, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Library", + "lighting_secondary_space_type": "Reading Area", + "lighting_power_density": 0.82, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "Recovery Room", + "lighting_power_density": 1.03, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Facility For The Visually Impaired", + "lighting_secondary_space_type": "Recreation Room/common Living Room (and Not Used Primarily By Staff)", + "lighting_power_density": 1.8, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Museum", + "lighting_secondary_space_type": "Restoration Room", + "lighting_power_density": 0.85, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (type 1)", + "lighting_power_density": 0.45, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (type 2)", + "lighting_power_density": 0.45, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (type 3)", + "lighting_power_density": 1.05, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (type 4)", + "lighting_power_density": 1.88, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Warehouse\u00e2\u20ac\u201dstorage Area", + "lighting_secondary_space_type": "Smaller, Hand-carried Items", + "lighting_power_density": 0.69, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Library", + "lighting_secondary_space_type": "Stacks", + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Transportation Facility", + "lighting_secondary_space_type": "Terminal Ticket Counter", + "lighting_power_density": 0.62, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Religious Facility", + "lighting_secondary_space_type": "Worship/Pulpit/Choir Area", + "lighting_power_density": 1.53, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "None", + "lighting_secondary_space_type": "None", + "lighting_power_density": 0, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2019.csv b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2019.csv index a2f8971a4a..951dc59e50 100644 --- a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2019.csv +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2019.csv @@ -1,139 +1,140 @@ -method,lighting_primary_space_type,lighting_per_area,lighting_secondary_space_type,lighting_per_area_unit,annotation -BA,Automotive facility,0.75,General,W/ft2, -BA,Convention center,0.64,General,W/ft2, -BA,Courthouse,0.79,General,W/ft2, -BA,Dining: Bar lounge/leisure,0.8,General,W/ft2, -BA,Dining: Cafeteria/fast food,0.76,General,W/ft2, -BA,Dining: Family,0.71,General,W/ft2, -BA,Dormitory,0.53,General,W/ft2, -BA,Exercise center,0.72,General,W/ft2, -BA,Fire station,0.56,General,W/ft2, -BA,Gymnasium,0.76,General,W/ft2, -BA,Health-care clinic,0.81,General,W/ft2, -BA,Hospital,0.96,General,W/ft2, -BA,Hotel/motel,0.56,General,W/ft2, -BA,Library,0.83,General,W/ft2, -BA,Manufacturing facility,0.82,General,W/ft2, -BA,Motion picture theater,0.44,General,W/ft2, -BA,Multifamily,0.45,General,W/ft2, -BA,Museum,0.55,General,W/ft2, -BA,Office,0.64,General,W/ft2, -BA,Parking garage,0.18,General,W/ft2, -BA,Penitentiary,0.69,General,W/ft2, -BA,Performing arts theater,0.84,General,W/ft2, -BA,Police station,0.66,General,W/ft2, -BA,Post office,0.65,General,W/ft2, -BA,Religious facility,0.67,General,W/ft2, -BA,Retail,0.84,General,W/ft2, -BA,School/university,0.72,General,W/ft2, -BA,Sports arena,0.76,General,W/ft2, -BA,Town hall,0.69,General,W/ft2, -BA,Transportation,0.5,General,W/ft2, -BA,Warehouse,0.45,General,W/ft2, -BA,Workshop,0.91,General,W/ft2, -CS,Atrium,0.39,< 20 ft in height,W/ft2, -CS,Atrium,0.48,>= 20 ft and <= 40 ft in height,W/ft2, -CS,Atrium,0.6,> 40 ft in height,W/ft2, -CS,Audience Seating Area,0.61,Auditorium,W/ft2, -CS,Audience Seating Area,0.23,Gymnasium,W/ft2, -CS,Audience Seating Area,0.27,Motion picture theater,W/ft2, -CS,Audience Seating Area,0.67,Penitentiary,W/ft2, -CS,Audience Seating Area,1.16,Performing arts theater,W/ft2, -CS,Audience Seating Area,0.72,Religious facility,W/ft2, -CS,Audience Seating Area,0.33,Sports arena,W/ft2, -CS,Audience Seating Area,0.23,All other audience seating areas,W/ft2, -CS,Banking Activity Area,0.61,General,W/ft2, -CS,Breakroom,0.59,General,W/ft2,(See Lounge/Breakroom) -CS,Classroom/Lecture Hall/Training Room,0.89,Penitentiary,W/ft2, -CS,Classroom/Lecture Hall/Training Room,0.71,All other classrooms/lecture halls/training rooms,W/ft2, -CS,Conference/Meeting/Multipurpose Room,0.97,General,W/ft2, -CS,Confinement Cells,0.7,General,W/ft2, -CS,Copy/Print Room,0.31,General,W/ft2, -CS,Corridor,0.71,Facility for the visually impaired (and not used primarily by the staff),W/ft2, -CS,Corridor,0.71,Hospital,W/ft2, -CS,Corridor,0.41,All other corridors,W/ft2, -CS,Courtroom,1.2,General,W/ft2, -CS,Computer Room,0.94,General,W/ft2, -CS,Dining Area,0.42,Penitentiary,W/ft2, -CS,Dining Area,1.27,Facility for the visually impaired (and not used primarily by staff),W/ft2, -CS,Dining Area,0.86,Bar/lounge or leisure dining,W/ft2, -CS,Dining Area,0.4,Cafeteria or fast food dining,W/ft2, -CS,Dining Area,0.6,Family dining,W/ft2, -CS,Dining Area,0.43,All other dining areas,W/ft2, -CS,Electrical/Mechanical Room,0.43,General,W/ft2, -CS,Emergency Vehicle Garage,0.52,General,W/ft2, -CS,Food Preparation Area,1.09,General,W/ft2, -CS,Guest Room,0.41,General,W/ft2, -CS,Laboratory,1.11,In or as a classroom,W/ft2, -CS,Laboratory,1.33,All other laboratories,W/ft2, -CS,Laundry/Washing Area,0.53,General,W/ft2, -CS,"Loading Dock, Interior",0.88,General,W/ft2, -CS,Lobby,1.69,Facility for the visually impaired (and not used primarily by the staff),W/ft2, -CS,Lobby,0.65,Elevator,W/ft2, -CS,Lobby,0.51,Hotel,W/ft2, -CS,Lobby,0.23,Motion picture theater,W/ft2, -CS,Lobby,1.25,Performing arts theater ,W/ft2, -CS,Lobby,0.84,All other lobbies,W/ft2, -CS,Locker Room,0.52,General,W/ft2, -CS,Lounge/Breakroom,0.42,Healthcare facility,W/ft2, -CS,Lounge/Breakroom,0.59,All other lounges/breakrooms,W/ft2, -CS,Office,0.74,Enclosed and <= 250 ft2,W/ft2, -CS,Office,0.66,Enclosed and > 250 ft2,W/ft2, -CS,Office,0.61,Open plan,W/ft2, -CS,"Parking Area, Interior",0.15,General,W/ft2, -CS,Pharmacy Area,1.66,General,W/ft2, -CS,Restroom,1.26,Facility for the visually impaired (and not used primarily by the staff),W/ft2, -CS,Restroom,0.63,All other restrooms,W/ft2, -CS,Sales Area,1.05,General,W/ft2, -CS,"Seating Area, General",0.23,General,W/ft2, -CS,Stairway,0.49,General,W/ft2,The space containing the stairway shall determine the LPD and control requirements for the stairway. -CS,Stairwell,0.49,General,W/ft2, -CS,Storage Room,0.51,< 50 ft2,W/ft2, -CS,Storage Room,0.38,>= 50 ft2,W/ft2, -CS,Vehicular Maintenance Area,0.6,General,W/ft2, -CS,Workshop,1.26,General,W/ft2, -SS,Facility for the Visually Impaired,0.7,Chapel (used primarily by residents),W/ft2, -SS,Facility for the Visually Impaired,1.77,Recreation room/common living room (and not used primarily by staff),W/ft2, -SS,Automotive,0.6,General,W/ft2,(See 'Vehicular Maintenance Area') -SS,Convention Center: Exhibit Space,0.61,General,W/ft2, -SS,Dormitory: Living Quarters,0.5,General,W/ft2, -SS,Fire Station: Sleeping Quarters,0.23,General,W/ft2, -SS,Gymnasium/Fitness Center,0.9,Exercise area,W/ft2, -SS,Gymnasium/Fitness Center,0.85,Playing area,W/ft2, -SS,Healthcare Facility,1.4,Exam/treatment room,W/ft2, -SS,Healthcare Facility,0.94,Imaging room,W/ft2, -SS,Healthcare Facility,0.62,Medical supply room,W/ft2, -SS,Healthcare Facility,0.92,Nursery,W/ft2, -SS,Healthcare Facility,1.17,Nurse's station,W/ft2, -SS,Healthcare Facility,2.26,Operating room,W/ft2, -SS,Healthcare Facility,0.68,Patient room,W/ft2, -SS,Healthcare Facility,0.91,Physical therapy room,W/ft2, -SS,Healthcare Facility,1.25,Recovery room,W/ft2, -SS,Library,0.96,Reading area,W/ft2, -SS,Library,1.18,Stacks,W/ft2, -SS,Manufacturing Facility,0.8,Detailed manufacturing area,W/ft2, -SS,Manufacturing Facility,0.76,Equipment room,W/ft2, -SS,Manufacturing Facility,1.42,Extra high bay area (> 50 ft floor-to-ceiling height),W/ft2, -SS,Manufacturing Facility,1.24,High bay area (25 to 50 ft floor-to-ceiling height),W/ft2, -SS,Manufacturing Facility,0.86,Low bay area (< 25 ft floor-to-ceiling height),W/ft2, -SS,Museum,0.31,General exhibition area,W/ft2, -SS,Museum,1.1,Restoration room,W/ft2, -SS,Performing Arts Theater: Dressing Room,0.41,General,W/ft2, -SS,Post Office: Sorting Area,0.76,General,W/ft2, -SS,Religious Facility,0.54,Fellowship hall,W/ft2, -SS,Religious Facility,0.85,Worship/pulpit/choir area,W/ft2, -SS,Retail Facilities,0.51,Dressing/fitting room,W/ft2, -SS,Retail Facilities,0.82,Mall concourse,W/ft2, -SS,Sports Arena: Playing Area,2.94,Class I facility,W/ft2, -SS,Sports Arena: Playing Area,2.01,Class II facility,W/ft2, -SS,Sports Arena: Playing Area,1.3,Class III facility,W/ft2, -SS,Sports Arena: Playing Area,0.86,Class IV facility,W/ft2, -SS,Transportation Facility,0.39,Baggage/carousel area,W/ft2, -SS,Transportation Facility,0.25,Airport concourse,W/ft2, -SS,Transportation Facility,0.51,Ticket counter,W/ft2, -SS,Warehouse: Storage Area,0.33,"Medium to bulky, palletized items",W/ft2, -SS,Warehouse: Storage Area,0.69,"Smaller, hand-carried items",W/ft2, -SS,Retail,0.45,Sales Additional (Retail Area 1),W/ft2, -SS,Retail,0.45,Sales Additional (Retail Area 2),W/ft2, -SS,Retail,1.05,Sales Additional (Retail Area 3),W/ft2, -SS,Retail,1.88,Sales Additional (Retail Area 4),W/ft2, +method,lighting_primary_space_type,lighting_secondary_space_type,lighting_power_density,unit,rcr_threshold,automatic_daylight_responsive_controls_for_sidelighting,automatic_daylight_responsive_controls_for_toplighting,automatic_partial_off,automatic_full_off,scheduled_shutoff,annotation +BA,Automotive facility,General,0.75,W/ft2,,,,,,, +BA,Convention center,General,0.64,W/ft2,,,,,,, +BA,Courthouse,General,0.79,W/ft2,,,,,,, +BA,Dining: Bar lounge/leisure,General,0.8,W/ft2,,,,,,, +BA,Dining: Cafeteria/fast food,General,0.76,W/ft2,,,,,,, +BA,Dining: Family,General,0.71,W/ft2,,,,,,, +BA,Dormitory,General,0.53,W/ft2,,,,,,, +BA,Exercise center,General,0.72,W/ft2,,,,,,, +BA,Fire station,General,0.56,W/ft2,,,,,,, +BA,Gymnasium,General,0.76,W/ft2,,,,,,, +BA,Health-care clinic,General,0.81,W/ft2,,,,,,, +BA,Hospital,General,0.96,W/ft2,,,,,,, +BA,Hotel/motel,General,0.56,W/ft2,,,,,,, +BA,Library,General,0.83,W/ft2,,,,,,, +BA,Manufacturing facility,General,0.82,W/ft2,,,,,,, +BA,Motion picture theater,General,0.44,W/ft2,,,,,,, +BA,Multifamily,General,0.45,W/ft2,,,,,,, +BA,Museum,General,0.55,W/ft2,,,,,,, +BA,Office,General,0.64,W/ft2,,,,,,, +BA,Parking garage,General,0.18,W/ft2,,,,,,, +BA,Penitentiary,General,0.69,W/ft2,,,,,,, +BA,Performing arts theater,General,0.84,W/ft2,,,,,,, +BA,Police station,General,0.66,W/ft2,,,,,,, +BA,Post office,General,0.65,W/ft2,,,,,,, +BA,Religious facility,General,0.67,W/ft2,,,,,,, +BA,Retail,General,0.84,W/ft2,,,,,,, +BA,School/university,General,0.72,W/ft2,,,,,,, +BA,Sports arena,General,0.76,W/ft2,,,,,,, +BA,Town hall,General,0.69,W/ft2,,,,,,, +BA,Transportation,General,0.5,W/ft2,,,,,,, +BA,Warehouse,General,0.45,W/ft2,,,,,,, +BA,Workshop,General,0.91,W/ft2,,,,,,, +CS,Atrium,< 20 ft in height,0.39,W/ft2,,REQ,REQ,,ADD2,ADD2, +CS,Atrium,>= 20 ft and <= 40 ft in height,0.48,W/ft2,,REQ,REQ,,ADD2,ADD2, +CS,Atrium,> 40 ft in height,0.6,W/ft2,11,REQ,REQ,,ADD2,ADD2, +CS,Audience Seating Area,Auditorium,0.61,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Audience Seating Area,Gymnasium,0.23,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Audience Seating Area,Motion picture theater,0.27,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Audience Seating Area,Penitentiary,0.67,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Audience Seating Area,Performing arts theater,1.16,W/ft2,8,REQ,REQ,,ADD2,ADD2, +CS,Audience Seating Area,Religious facility,0.72,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Audience Seating Area,Sports arena,0.33,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Audience Seating Area,All other audience seating areas,0.23,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Banking Activity Area,General,0.61,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Breakroom,General,0.59,W/ft2,4,REQ,REQ,,REQ,, +CS,Classroom/Lecture Hall/Training Room,Penitentiary,0.89,W/ft2,4,REQ,REQ,,REQ,, +CS,Classroom/Lecture Hall/Training Room,All other classrooms/lecture halls/training rooms,0.71,W/ft2,4,REQ,REQ,,REQ,, +CS,Conference/Meeting/Multipurpose Room,General,0.97,W/ft2,6,REQ,REQ,,REQ,, +CS,Confinement Cells,General,0.7,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Copy/Print Room,General,0.31,W/ft2,6,REQ,REQ,,REQ,, +CS,Corridor,Facility for the visually impaired (and not used primarily by the staff),0.71,W/ft2,,REQ,REQ,REQ,ADD2,ADD2,rcr_threshold: width<8 ft +CS,Corridor,Hospital,0.71,W/ft2,,REQ,REQ,ADD2,ADD2,ADD2,rcr_threshold: width<8 ft +CS,Corridor,All other corridors,0.41,W/ft2,,REQ,REQ,REQ,ADD2,ADD2,rcr_threshold: width<8 ft +CS,Courtroom,General,1.2,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Computer Room,General,0.94,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Dining Area,Penitentiary,0.42,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Dining Area,Facility for the visually impaired (and not used primarily by staff),1.27,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Dining Area,Bar/lounge or leisure dining,0.86,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Dining Area,Cafeteria or fast food dining,0.4,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Dining Area,Family dining,0.6,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Dining Area,All other dining areas,0.43,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Electrical/Mechanical Room,General,0.43,W/ft2,6,REQ,REQ,,,, +CS,Emergency Vehicle Garage,General,0.52,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Food Preparation Area,General,1.09,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Guest Room,General,0.41,W/ft2,6,,,,,,See section 9.4.1.3(b) +CS,Laboratory,In or as a classroom,1.11,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, +CS,Laboratory,All other laboratories,1.33,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Laundry/Washing Area,General,0.53,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,"Loading Dock, Interior",General,0.88,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Lobby,Facility for the visually impaired (and not used primarily by the staff),1.69,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, +CS,Lobby,Elevator,0.65,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Lobby,Hotel,0.51,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Lobby,Motion picture theater,0.23,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Lobby,Performing arts theater ,1.25,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, +CS,Lobby,All other lobbies,0.84,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, +CS,Locker Room,General,0.52,W/ft2,6,REQ,REQ,,REQ,, +CS,Lounge/Breakroom,Healthcare facility,0.42,W/ft2,6,REQ,REQ,,REQ,, +CS,Lounge/Breakroom,All other lounges/breakrooms,0.59,W/ft2,4,REQ,REQ,,REQ,, +CS,Office,Enclosed and <= 250 ft2,0.74,W/ft2,8,REQ,REQ,,REQ,, +CS,Office,Enclosed and > 250 ft2,0.66,W/ft2,8,REQ,REQ,,ADD2,ADD2, +CS,Office,Open plan,0.61,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,"Parking Area, Interior",General,0.15,W/ft2,4,,,,,,See Section 9.4.1.2 +CS,Pharmacy Area,General,1.66,W/ft2,6,REQ,REQ,,ADD2,ADD2, +CS,Restroom,Facility for the visually impaired (and not used primarily by the staff),1.26,W/ft2,8,REQ,REQ,,REQ,, +CS,Restroom,All other restrooms,0.63,W/ft2,8,REQ,REQ,,REQ,, +CS,Sales Area,General,1.05,W/ft2,6,,REQ,,ADD2,ADD2, +CS,"Seating Area, General",General,0.23,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Stairway,General,0.49,W/ft2,10,REQ,REQ,REQ,ADD2,ADD2, +CS,Stairwell,General,0.49,W/ft2,10,REQ,REQ,REQ,ADD2,ADD2, +CS,Storage Room,< 50 ft2,0.51,W/ft2,9,,,,ADD2,ADD2, +CS,Storage Room,>= 50 ft2,0.38,W/ft2,6,REQ,REQ,,REQ,, +CS,Vehicular Maintenance Area,General,0.6,W/ft2,4,REQ,REQ,,ADD2,ADD2, +CS,Workshop,General,1.26,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Facility for the Visually Impaired,Chapel (used primarily by residents),0.7,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Facility for the Visually Impaired,Recreation room/common living room (and not used primarily by staff),1.77,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Automotive,General,0.6,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Convention Center: Exhibit Space,General,0.61,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Dormitory: Living Quarters,General,0.5,W/ft2,8,,,,,, +SS,Fire Station: Sleeping Quarters,General,0.23,W/ft2,6,,,,,, +SS,Gymnasium/Fitness Center,Exercise area,0.9,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Gymnasium/Fitness Center,Playing area,0.85,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Healthcare Facility,Exam/treatment room,1.4,W/ft2,8,REQ,REQ,,ADD2,ADD2, +SS,Healthcare Facility,Imaging room,0.94,W/ft2,6,,,,ADD2,ADD2, +SS,Healthcare Facility,Medical supply room,0.62,W/ft2,6,REQ,REQ,,REQ,, +SS,Healthcare Facility,Nursery,0.92,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Healthcare Facility,Nurse's station,1.17,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Healthcare Facility,Operating room,2.26,W/ft2,6,,,,ADD2,ADD2, +SS,Healthcare Facility,Patient room,0.68,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Healthcare Facility,Physical therapy room,0.91,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Healthcare Facility,Recovery room,1.25,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Library,Reading area,0.96,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Library,Stacks,1.18,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, +SS,Manufacturing Facility,Detailed manufacturing area,0.8,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Manufacturing Facility,Equipment room,0.76,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Manufacturing Facility,Extra high bay area (> 50 ft floor-to-ceiling height),1.42,W/ft2,8,REQ,REQ,,ADD2,ADD2, +SS,Manufacturing Facility,High bay area (25 to 50 ft floor-to-ceiling height),1.24,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Manufacturing Facility,Low bay area (< 25 ft floor-to-ceiling height),0.86,W/ft2,3,REQ,REQ,,ADD2,ADD2, +SS,Museum,General exhibition area,0.31,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Museum,Restoration room,1.1,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Performing Arts Theater: Dressing Room,General,0.41,W/ft2,6,REQ,REQ,,REQ,, +SS,Post Office: Sorting Area,General,0.76,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, +SS,Religious Facility,Fellowship hall,0.54,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Religious Facility,Worship/pulpit/choir area,0.85,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Retail Facilities,Dressing/fitting room,0.51,W/ft2,8,,REQ,,REQ,, +SS,Retail Facilities,Mall concourse,0.82,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Sports Arena: Playing Area,Class I facility,2.94,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Sports Arena: Playing Area,Class II facility,2.01,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Sports Arena: Playing Area,Class III facility,1.3,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Sports Arena: Playing Area,Class IV facility,0.86,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Transportation Facility,Baggage/carousel area,0.39,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Transportation Facility,Airport concourse,0.25,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Transportation Facility,Ticket counter,0.51,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Warehouse: Storage Area,"Medium to bulky, palletized items",0.33,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, +SS,Warehouse: Storage Area,"Smaller, hand-carried items",0.69,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, +SS,Retail,Sales Additional (Retail Area 1),0.45,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Retail,Sales Additional (Retail Area 2),0.45,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Retail,Sales Additional (Retail Area 3),1.05,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Retail,Sales Additional (Retail Area 4),1.88,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,None,None,0,W/ft2,,,,,,, diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2019.json b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2019.json index 92cd21efe0..63f5789ebe 100644 --- a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2019.json +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2019.json @@ -2,1105 +2,1947 @@ { "method": "BA", "lighting_primary_space_type": "Automotive facility", - "lighting_per_area": 0.75, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.75, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Convention center", - "lighting_per_area": 0.64, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.64, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Courthouse", - "lighting_per_area": 0.79, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.79, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Dining: Bar lounge/leisure", - "lighting_per_area": 0.8, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.8, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Dining: Cafeteria/fast food", - "lighting_per_area": 0.76, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.76, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Dining: Family", - "lighting_per_area": 0.71, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.71, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Dormitory", - "lighting_per_area": 0.53, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.53, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Exercise center", - "lighting_per_area": 0.72, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.72, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Fire station", - "lighting_per_area": 0.56, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.56, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Gymnasium", - "lighting_per_area": 0.76, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.76, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Health-care clinic", - "lighting_per_area": 0.81, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.81, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Hospital", - "lighting_per_area": 0.96, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.96, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Hotel/motel", - "lighting_per_area": 0.56, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.56, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Library", - "lighting_per_area": 0.83, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.83, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Manufacturing facility", - "lighting_per_area": 0.82, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.82, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Motion picture theater", - "lighting_per_area": 0.44, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.44, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Multifamily", - "lighting_per_area": 0.45, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.45, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Museum", - "lighting_per_area": 0.55, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.55, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Office", - "lighting_per_area": 0.64, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.64, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Parking garage", - "lighting_per_area": 0.18, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.18, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Penitentiary", - "lighting_per_area": 0.69, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.69, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Performing arts theater", - "lighting_per_area": 0.84, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.84, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Police station", - "lighting_per_area": 0.66, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.66, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Post office", - "lighting_per_area": 0.65, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.65, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Religious facility", - "lighting_per_area": 0.67, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.67, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Retail", - "lighting_per_area": 0.84, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.84, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "School/university", - "lighting_per_area": 0.72, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.72, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Sports arena", - "lighting_per_area": 0.76, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.76, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Town hall", - "lighting_per_area": 0.69, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.69, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Transportation", - "lighting_per_area": 0.5, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.5, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Warehouse", - "lighting_per_area": 0.45, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.45, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "BA", "lighting_primary_space_type": "Workshop", - "lighting_per_area": 0.91, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.91, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Atrium", - "lighting_per_area": 0.39, "lighting_secondary_space_type": "< 20 ft in height", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.39, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Atrium", - "lighting_per_area": 0.48, "lighting_secondary_space_type": ">= 20 ft and <= 40 ft in height", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.48, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Atrium", - "lighting_per_area": 0.6, "lighting_secondary_space_type": "> 40 ft in height", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.6, + "unit": "W/ft2", + "rcr_threshold": 11, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Audience Seating Area", - "lighting_per_area": 0.61, "lighting_secondary_space_type": "Auditorium", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.61, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Audience Seating Area", - "lighting_per_area": 0.23, "lighting_secondary_space_type": "Gymnasium", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.23, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Audience Seating Area", - "lighting_per_area": 0.27, "lighting_secondary_space_type": "Motion picture theater", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.27, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Audience Seating Area", - "lighting_per_area": 0.67, "lighting_secondary_space_type": "Penitentiary", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.67, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Audience Seating Area", - "lighting_per_area": 1.16, "lighting_secondary_space_type": "Performing arts theater", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.16, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Audience Seating Area", - "lighting_per_area": 0.72, "lighting_secondary_space_type": "Religious facility", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.72, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Audience Seating Area", - "lighting_per_area": 0.33, "lighting_secondary_space_type": "Sports arena", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.33, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Audience Seating Area", - "lighting_per_area": 0.23, "lighting_secondary_space_type": "All other audience seating areas", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.23, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Banking Activity Area", - "lighting_per_area": 0.61, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.61, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Breakroom", - "lighting_per_area": 0.59, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "(See Lounge/Breakroom)" + "lighting_power_density": 0.59, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Classroom/Lecture Hall/Training Room", - "lighting_per_area": 0.89, "lighting_secondary_space_type": "Penitentiary", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.89, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Classroom/Lecture Hall/Training Room", - "lighting_per_area": 0.71, "lighting_secondary_space_type": "All other classrooms/lecture halls/training rooms", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.71, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Conference/Meeting/Multipurpose Room", - "lighting_per_area": 0.97, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.97, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Confinement Cells", - "lighting_per_area": 0.7, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.7, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Copy/Print Room", - "lighting_per_area": 0.31, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.31, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Corridor", - "lighting_per_area": 0.71, "lighting_secondary_space_type": "Facility for the visually impaired (and not used primarily by the staff)", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.71, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": "rcr_threshold: width<8 ft" }, { "method": "CS", "lighting_primary_space_type": "Corridor", - "lighting_per_area": 0.71, "lighting_secondary_space_type": "Hospital", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.71, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "ADD2", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": "rcr_threshold: width<8 ft" }, { "method": "CS", "lighting_primary_space_type": "Corridor", - "lighting_per_area": 0.41, "lighting_secondary_space_type": "All other corridors", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.41, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": "rcr_threshold: width<8 ft" }, { "method": "CS", "lighting_primary_space_type": "Courtroom", - "lighting_per_area": 1.2, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.2, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Computer Room", - "lighting_per_area": 0.94, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.94, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Dining Area", - "lighting_per_area": 0.42, "lighting_secondary_space_type": "Penitentiary", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.42, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Dining Area", - "lighting_per_area": 1.27, "lighting_secondary_space_type": "Facility for the visually impaired (and not used primarily by staff)", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.27, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Dining Area", - "lighting_per_area": 0.86, "lighting_secondary_space_type": "Bar/lounge or leisure dining", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.86, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Dining Area", - "lighting_per_area": 0.4, "lighting_secondary_space_type": "Cafeteria or fast food dining", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.4, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Dining Area", - "lighting_per_area": 0.6, "lighting_secondary_space_type": "Family dining", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.6, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Dining Area", - "lighting_per_area": 0.43, "lighting_secondary_space_type": "All other dining areas", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.43, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Electrical/Mechanical Room", - "lighting_per_area": 0.43, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.43, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Emergency Vehicle Garage", - "lighting_per_area": 0.52, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.52, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Food Preparation Area", - "lighting_per_area": 1.09, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.09, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Guest Room", - "lighting_per_area": 0.41, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.41, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": "See section 9.4.1.3(b)" }, { "method": "CS", "lighting_primary_space_type": "Laboratory", - "lighting_per_area": 1.11, "lighting_secondary_space_type": "In or as a classroom", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.11, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Laboratory", - "lighting_per_area": 1.33, "lighting_secondary_space_type": "All other laboratories", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.33, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Laundry/Washing Area", - "lighting_per_area": 0.53, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.53, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Loading Dock, Interior", - "lighting_per_area": 0.88, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.88, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Lobby", - "lighting_per_area": 1.69, "lighting_secondary_space_type": "Facility for the visually impaired (and not used primarily by the staff)", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.69, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Lobby", - "lighting_per_area": 0.65, "lighting_secondary_space_type": "Elevator", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.65, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Lobby", - "lighting_per_area": 0.51, "lighting_secondary_space_type": "Hotel", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.51, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Lobby", - "lighting_per_area": 0.23, "lighting_secondary_space_type": "Motion picture theater", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.23, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Lobby", - "lighting_per_area": 1.25, "lighting_secondary_space_type": "Performing arts theater ", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.25, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Lobby", - "lighting_per_area": 0.84, "lighting_secondary_space_type": "All other lobbies", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.84, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Locker Room", - "lighting_per_area": 0.52, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.52, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Lounge/Breakroom", - "lighting_per_area": 0.42, "lighting_secondary_space_type": "Healthcare facility", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.42, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Lounge/Breakroom", - "lighting_per_area": 0.59, "lighting_secondary_space_type": "All other lounges/breakrooms", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.59, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Office", - "lighting_per_area": 0.74, "lighting_secondary_space_type": "Enclosed and <= 250 ft2", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.74, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Office", - "lighting_per_area": 0.66, "lighting_secondary_space_type": "Enclosed and > 250 ft2", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.66, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Office", - "lighting_per_area": 0.61, "lighting_secondary_space_type": "Open plan", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.61, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Parking Area, Interior", - "lighting_per_area": 0.15, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.15, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": "See Section 9.4.1.2" }, { "method": "CS", "lighting_primary_space_type": "Pharmacy Area", - "lighting_per_area": 1.66, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.66, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Restroom", - "lighting_per_area": 1.26, "lighting_secondary_space_type": "Facility for the visually impaired (and not used primarily by the staff)", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.26, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Restroom", - "lighting_per_area": 0.63, "lighting_secondary_space_type": "All other restrooms", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.63, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Sales Area", - "lighting_per_area": 1.05, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.05, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Seating Area, General", - "lighting_per_area": 0.23, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.23, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Stairway", - "lighting_per_area": 0.49, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "The space containing the stairway shall determine the LPD and control requirements for the stairway." + "lighting_power_density": 0.49, + "unit": "W/ft2", + "rcr_threshold": 10, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Stairwell", - "lighting_per_area": 0.49, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.49, + "unit": "W/ft2", + "rcr_threshold": 10, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Storage Room", - "lighting_per_area": 0.51, "lighting_secondary_space_type": "< 50 ft2", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.51, + "unit": "W/ft2", + "rcr_threshold": 9, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Storage Room", - "lighting_per_area": 0.38, "lighting_secondary_space_type": ">= 50 ft2", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.38, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Vehicular Maintenance Area", - "lighting_per_area": 0.6, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.6, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Workshop", - "lighting_per_area": 1.26, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.26, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Facility for the Visually Impaired", - "lighting_per_area": 0.7, "lighting_secondary_space_type": "Chapel (used primarily by residents)", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.7, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Facility for the Visually Impaired", - "lighting_per_area": 1.77, "lighting_secondary_space_type": "Recreation room/common living room (and not used primarily by staff)", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.77, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Automotive", - "lighting_per_area": 0.6, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "(See 'Vehicular Maintenance Area')" + "lighting_power_density": 0.6, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Convention Center: Exhibit Space", - "lighting_per_area": 0.61, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.61, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Dormitory: Living Quarters", - "lighting_per_area": 0.5, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.5, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Fire Station: Sleeping Quarters", - "lighting_per_area": 0.23, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.23, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Gymnasium/Fitness Center", - "lighting_per_area": 0.9, "lighting_secondary_space_type": "Exercise area", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.9, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Gymnasium/Fitness Center", - "lighting_per_area": 0.85, "lighting_secondary_space_type": "Playing area", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.85, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Healthcare Facility", - "lighting_per_area": 1.4, "lighting_secondary_space_type": "Exam/treatment room", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.4, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Healthcare Facility", - "lighting_per_area": 0.94, "lighting_secondary_space_type": "Imaging room", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.94, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Healthcare Facility", - "lighting_per_area": 0.62, "lighting_secondary_space_type": "Medical supply room", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.62, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Healthcare Facility", - "lighting_per_area": 0.92, "lighting_secondary_space_type": "Nursery", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.92, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Healthcare Facility", - "lighting_per_area": 1.17, "lighting_secondary_space_type": "Nurse's station", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.17, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Healthcare Facility", - "lighting_per_area": 2.26, "lighting_secondary_space_type": "Operating room", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 2.26, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Healthcare Facility", - "lighting_per_area": 0.68, "lighting_secondary_space_type": "Patient room", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.68, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Healthcare Facility", - "lighting_per_area": 0.91, "lighting_secondary_space_type": "Physical therapy room", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.91, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Healthcare Facility", - "lighting_per_area": 1.25, "lighting_secondary_space_type": "Recovery room", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.25, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Library", - "lighting_per_area": 0.96, "lighting_secondary_space_type": "Reading area", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.96, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Library", - "lighting_per_area": 1.18, "lighting_secondary_space_type": "Stacks", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.18, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Manufacturing Facility", - "lighting_per_area": 0.8, "lighting_secondary_space_type": "Detailed manufacturing area", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.8, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Manufacturing Facility", - "lighting_per_area": 0.76, "lighting_secondary_space_type": "Equipment room", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.76, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Manufacturing Facility", - "lighting_per_area": 1.42, "lighting_secondary_space_type": "Extra high bay area (> 50 ft floor-to-ceiling height)", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.42, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Manufacturing Facility", - "lighting_per_area": 1.24, "lighting_secondary_space_type": "High bay area (25 to 50 ft floor-to-ceiling height)", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.24, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Manufacturing Facility", - "lighting_per_area": 0.86, "lighting_secondary_space_type": "Low bay area (< 25 ft floor-to-ceiling height)", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.86, + "unit": "W/ft2", + "rcr_threshold": 3, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Museum", - "lighting_per_area": 0.31, "lighting_secondary_space_type": "General exhibition area", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.31, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Museum", - "lighting_per_area": 1.1, "lighting_secondary_space_type": "Restoration room", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.1, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Performing Arts Theater: Dressing Room", - "lighting_per_area": 0.41, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.41, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Post Office: Sorting Area", - "lighting_per_area": 0.76, "lighting_secondary_space_type": "General", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.76, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Religious Facility", - "lighting_per_area": 0.54, "lighting_secondary_space_type": "Fellowship hall", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.54, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Religious Facility", - "lighting_per_area": 0.85, "lighting_secondary_space_type": "Worship/pulpit/choir area", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.85, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Retail Facilities", - "lighting_per_area": 0.51, "lighting_secondary_space_type": "Dressing/fitting room", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.51, + "unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Retail Facilities", - "lighting_per_area": 0.82, "lighting_secondary_space_type": "Mall concourse", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.82, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Sports Arena: Playing Area", - "lighting_per_area": 2.94, "lighting_secondary_space_type": "Class I facility", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 2.94, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Sports Arena: Playing Area", - "lighting_per_area": 2.01, "lighting_secondary_space_type": "Class II facility", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 2.01, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Sports Arena: Playing Area", - "lighting_per_area": 1.3, "lighting_secondary_space_type": "Class III facility", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.3, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Sports Arena: Playing Area", - "lighting_per_area": 0.86, "lighting_secondary_space_type": "Class IV facility", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.86, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Transportation Facility", - "lighting_per_area": 0.39, "lighting_secondary_space_type": "Baggage/carousel area", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.39, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Transportation Facility", - "lighting_per_area": 0.25, "lighting_secondary_space_type": "Airport concourse", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.25, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Transportation Facility", - "lighting_per_area": 0.51, "lighting_secondary_space_type": "Ticket counter", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.51, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Warehouse: Storage Area", - "lighting_per_area": 0.33, "lighting_secondary_space_type": "Medium to bulky, palletized items", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.33, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Warehouse: Storage Area", - "lighting_per_area": 0.69, "lighting_secondary_space_type": "Smaller, hand-carried items", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.69, + "unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Retail", - "lighting_per_area": 0.45, "lighting_secondary_space_type": "Sales Additional (Retail Area 1)", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.45, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Retail", - "lighting_per_area": 0.45, "lighting_secondary_space_type": "Sales Additional (Retail Area 2)", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 0.45, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Retail", - "lighting_per_area": 1.05, "lighting_secondary_space_type": "Sales Additional (Retail Area 3)", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.05, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Retail", - "lighting_per_area": 1.88, "lighting_secondary_space_type": "Sales Additional (Retail Area 4)", - "lighting_per_area_unit": "W/ft2", - "annotation": "" + "lighting_power_density": 1.88, + "unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "None", + "lighting_secondary_space_type": "None", + "lighting_power_density": 0, + "unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null } ] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_1999.csv b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_1999.csv new file mode 100644 index 0000000000..dc81d12379 --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_1999.csv @@ -0,0 +1,84 @@ +ventilation_primary_space_type,ventilation_secondary_space_type,ventilation_rate_occupant,ventilation_rate_occupant_unit,ventilation_rate_area,ventilation_rate_area_unit,occupancy_per_area,occupancy_per_area_unit,air_class,os,annotation +"Dry Cleaners, Laundries",Commercial laundry,25,cfm/person,0,cfm/ft2,10,ppl/1000 ft2,,, +"Dry Cleaners, Laundries",Commercial dry cleaner,30,cfm/person,0,cfm/ft2,30,ppl/1000 ft2,,, +"Dry Cleaners, Laundries","Storage, pick up",35,cfm/person,0,cfm/ft2,30,ppl/1000 ft2,,, +"Dry Cleaners, Laundries",Coin-operated laundries,15,cfm/person,0,cfm/ft2,20,ppl/1000 ft2,,, +"Dry Cleaners, Laundries",Coin-operated dry cleaner,15,cfm/person,0,cfm/ft2,20,ppl/1000 ft2,,, +Foor and Beverage Service,Dining rooms,20,cfm/person,0,cfm/ft2,70,ppl/1000 ft2,,, +Foor and Beverage Service,"Cafeteria, fast food",20,cfm/person,0,cfm/ft2,100,ppl/1000 ft2,,, +Foor and Beverage Service,"Bars, cocktails lounges",30,cfm/person,0,cfm/ft2,100,ppl/1000 ft2,,, +Foor and Beverage Service,Kitchen (cooking),15,cfm/person,0,cfm/ft2,20,ppl/1000 ft2,,, +"Garages, Repair, Service Stations",Enclosed parking garage,0,cfm/person,1.5,cfm/ft2,0,ppl/1000 ft2,,, +"Garages, Repair, Service Stations",Auto repair rooms,0,cfm/person,1.5,cfm/ft2,0,ppl/1000 ft2,,, +"Hotels, Motels, Resorts, Dormitories",Bedrooms,0,cfm/person,30,cfm/room,0,ppl/1000 ft2,,, +"Hotels, Motels, Resorts, Dormitories",Living rooms,0,cfm/person,30,cfm/room,0,ppl/1000 ft2,,, +"Hotels, Motels, Resorts, Dormitories",Baths,0,cfm/person,35,cfm/room,0,ppl/1000 ft2,,, +"Hotels, Motels, Resorts, Dormitories",Lobbies,15,cfm/person,0,cfm/ft2,30,ppl/1000 ft2,,, +"Hotels, Motels, Resorts, Dormitories",Conference rooms,20,cfm/person,0,cfm/ft2,50,ppl/1000 ft2,,, +"Hotels, Motels, Resorts, Dormitories",Assembly rooms,15,cfm/person,0,cfm/ft2,120,ppl/1000 ft2,,, +"Hotels, Motels, Resorts, Dormitories",Dormitory sleeping areas,15,cfm/person,0,cfm/ft2,20,ppl/1000 ft2,,, +"Hotels, Motels, Resorts, Dormitories",Gambling casinos,30,cfm/person,0,cfm/ft2,120,ppl/1000 ft2,,, +Offices,Office space,20,cfm/person,0,cfm/ft2,7,ppl/1000 ft2,,, +Offices,Reception areas,15,cfm/person,0,cfm/ft2,60,ppl/1000 ft2,,, +Offices,Telecommunitcation centers and data entry areas,20,cfm/person,0,cfm/ft2,60,ppl/1000 ft2,,, +Offices,Conference rooms,20,cfm/person,0,cfm/ft2,50,ppl/1000 ft2,,, +Public Spaces,Corridors and utilities,0,cfm/person,0.05,cfm/ft2,0,ppl/1000 ft2,,, +Public Spaces,"Public restrooms, cfm/wc or cfm/urinal",50,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,,, +Public Spaces,Locker and dressing rooms,0,cfm/person,0.5,cfm/ft2,0,ppl/1000 ft2,,, +Public Spaces,Smoking lounge,60,cfm/person,0,cfm/ft2,70,ppl/1000 ft2,,, +Public Spaces,Elevators,0,cfm/person,1,cfm/ft2,0,ppl/1000 ft2,,, +"Retail Stores, Sales Floors, and Show Room Floors",Basement and street,0,cfm/person,0.3,cfm/ft2,30,ppl/1000 ft2,,, +"Retail Stores, Sales Floors, and Show Room Floors",Upper floors,0,cfm/person,0.2,cfm/ft2,20,ppl/1000 ft2,,, +"Retail Stores, Sales Floors, and Show Room Floors",Storage rooms,0,cfm/person,0.15,cfm/ft2,15,ppl/1000 ft2,,, +"Retail Stores, Sales Floors, and Show Room Floors",Dressing rooms,0,cfm/person,0.2,cfm/ft2,0,ppl/1000 ft2,,, +"Retail Stores, Sales Floors, and Show Room Floors",Malls and arcades,0,cfm/person,0.2,cfm/ft2,20,ppl/1000 ft2,,, +"Retail Stores, Sales Floors, and Show Room Floors",Shipping and receiving,0,cfm/person,0.15,cfm/ft2,10,ppl/1000 ft2,,, +"Retail Stores, Sales Floors, and Show Room Floors",Warehouses,0,cfm/person,0.05,cfm/ft2,5,ppl/1000 ft2,,, +"Retail Stores, Sales Floors, and Show Room Floors",Smoking lounge,60,cfm/person,0,cfm/ft2,70,ppl/1000 ft2,,, +Specialty Shops,Barber,15,cfm/person,0,cfm/ft2,25,ppl/1000 ft2,,, +Specialty Shops,Beauty,25,cfm/person,0,cfm/ft2,25,ppl/1000 ft2,,, +Specialty Shops,Reducing salons,15,cfm/person,0,cfm/ft2,20,ppl/1000 ft2,,, +Specialty Shops,Florists,15,cfm/person,0,cfm/ft2,8,ppl/1000 ft2,,, +Specialty Shops,"Clothiers, furniture",0,cfm/person,0.3,cfm/ft2,0,ppl/1000 ft2,,, +Specialty Shops,"Hardwar, drugs, fabric",15,cfm/person,0,cfm/ft2,8,ppl/1000 ft2,,, +Specialty Shops,Supermarkets,15,cfm/person,0,cfm/ft2,8,ppl/1000 ft2,,, +Specialty Shops,Pet shops,0,cfm/person,1,cfm/ft2,0,ppl/1000 ft2,,, +Sports and Amusement,Spectator areas,15,cfm/person,0,cfm/ft2,150,ppl/1000 ft2,,, +Sports and Amusement,Game rooms,25,cfm/person,0,cfm/ft2,70,ppl/1000 ft2,,, +Sports and Amusement,Ice arenas (playing areas),0,cfm/person,0.5,cfm/ft2,0,ppl/1000 ft2,,, +Sports and Amusement,Swimming pools (pool and deck area),0,cfm/person,0.5,cfm/ft2,0,ppl/1000 ft2,,, +Sports and Amusement,Playing floors (gymnasium),20,cfm/person,0,cfm/ft2,30,ppl/1000 ft2,,, +Sports and Amusement,Ballrooms and discos,25,cfm/person,0,cfm/ft2,100,ppl/1000 ft2,,, +Sports and Amusement,Bowling alleys (seating areas),25,cfm/person,0,cfm/ft2,70,ppl/1000 ft2,,, +Theaters,Ticket booths,20,cfm/person,0,cfm/ft2,60,ppl/1000 ft2,,, +Theaters,Lobbies,20,cfm/person,0,cfm/ft2,15,ppl/1000 ft2,,, +Theaters,Auditorium,15,cfm/person,0,cfm/ft2,150,ppl/1000 ft2,,, +Theaters,"Stages, studios",15,cfm/person,0,cfm/ft2,70,ppl/1000 ft2,,, +Transportation,Waiting rooms,15,cfm/person,0,cfm/ft2,100,ppl/1000 ft2,,, +Transportation,Platforms,15,cfm/person,0,cfm/ft2,100,ppl/1000 ft2,,, +Transportation,Vehicles,15,cfm/person,0,cfm/ft2,150,ppl/1000 ft2,,, +Workrooms,Meat processing,10,cfm/person,0,cfm/ft2,10,ppl/1000 ft2,,, +Workrooms,Photo studios,15,cfm/person,0,cfm/ft2,10,ppl/1000 ft2,,, +Workrooms,Darkrooms,0,cfm/person,0.5,cfm/ft2,10,ppl/1000 ft2,,, +Workrooms,Pharmacy,15,cfm/person,0,cfm/ft2,20,ppl/1000 ft2,,, +Workrooms,Bank vaults,15,cfm/person,0,cfm/ft2,5,ppl/1000 ft2,,, +Workrooms,"Duplicating, printing",0,cfm/person,0.5,cfm/ft2,0,ppl/1000 ft2,,, +Education,Classroom,15,cfm/person,0,cfm/ft2,50,ppl/1000 ft2,,, +Education,Laboratories,20,cfm/person,0,cfm/ft2,30,ppl/1000 ft2,,, +Education,Training shop,20,cfm/person,0,cfm/ft2,30,ppl/1000 ft2,,, +Education,Music rooms,15,cfm/person,0,cfm/ft2,50,ppl/1000 ft2,,, +Education,Libraries,15,cfm/person,0,cfm/ft2,20,ppl/1000 ft2,,, +Education,Locker rooms,0,cfm/person,0.5,cfm/ft2,0,ppl/1000 ft2,,, +Education,Corridors,0,cfm/person,0.1,cfm/ft2,0,ppl/1000 ft2,,, +Education,Auditoriums,15,cfm/person,0,cfm/ft2,150,ppl/1000 ft2,,, +Education,Smoking lounge,60,cfm/person,0,cfm/ft2,710,ppl/1000 ft2,,, +"Hospitals, Nursing and Convalescent Homes",Patient rooms,25,cfm/person,0,cfm/ft2,10,ppl/1000 ft2,,, +"Hospitals, Nursing and Convalescent Homes",Medical procedure,15,cfm/person,0,cfm/ft2,20,ppl/1000 ft2,,, +"Hospitals, Nursing and Convalescent Homes",Operating rooms,30,cfm/person,0,cfm/ft2,20,ppl/1000 ft2,,, +"Hospitals, Nursing and Convalescent Homes",Recovery and ICU,15,cfm/person,0,cfm/ft2,20,ppl/1000 ft2,,, +"Hospitals, Nursing and Convalescent Homes",Autopsy rooms,0,cfm/person,0.5,cfm/ft2,0,ppl/1000 ft2,,, +"Hospitals, Nursing and Convalescent Homes",Physical therapy,15,cfm/person,0,cfm/ft2,20,ppl/1000 ft2,,, +Correctional Facilties,Cells,20,cfm/person,0,cfm/ft2,20,ppl/1000 ft2,,, +Correctional Facilties,Dining halls,15,cfm/person,0,cfm/ft2,100,ppl/1000 ft2,,, +Correctional Facilties,Guard stations,15,cfm/person,0,cfm/ft2,40,ppl/1000 ft2,,, +None,None,0,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,,, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_1999.json b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_1999.json new file mode 100644 index 0000000000..446dbc8eee --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_1999.json @@ -0,0 +1,1081 @@ +[ + { + "ventilation_primary_space_type": "Dry Cleaners, Laundries", + "ventilation_secondary_space_type": "Commercial laundry", + "ventilation_rate_occupant": 25, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Dry Cleaners, Laundries", + "ventilation_secondary_space_type": "Commercial dry cleaner", + "ventilation_rate_occupant": 30, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 30, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Dry Cleaners, Laundries", + "ventilation_secondary_space_type": "Storage, pick up", + "ventilation_rate_occupant": 35, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 30, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Dry Cleaners, Laundries", + "ventilation_secondary_space_type": "Coin-operated laundries", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Dry Cleaners, Laundries", + "ventilation_secondary_space_type": "Coin-operated dry cleaner", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Foor and Beverage Service", + "ventilation_secondary_space_type": "Dining rooms", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 70, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Foor and Beverage Service", + "ventilation_secondary_space_type": "Cafeteria, fast food", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Foor and Beverage Service", + "ventilation_secondary_space_type": "Bars, cocktails lounges", + "ventilation_rate_occupant": 30, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Foor and Beverage Service", + "ventilation_secondary_space_type": "Kitchen (cooking)", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Garages, Repair, Service Stations", + "ventilation_secondary_space_type": "Enclosed parking garage", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 1.5, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Garages, Repair, Service Stations", + "ventilation_secondary_space_type": "Auto repair rooms", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 1.5, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Bedrooms", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 30, + "ventilation_rate_area_unit": "cfm/room", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Living rooms", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 30, + "ventilation_rate_area_unit": "cfm/room", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Baths", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 35, + "ventilation_rate_area_unit": "cfm/room", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Lobbies", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 30, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Conference rooms", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 50, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Assembly rooms", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 120, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Dormitory sleeping areas", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Gambling casinos", + "ventilation_rate_occupant": 30, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 120, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Offices", + "ventilation_secondary_space_type": "Office space", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 7, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Offices", + "ventilation_secondary_space_type": "Reception areas", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 60, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Offices", + "ventilation_secondary_space_type": "Telecommunitcation centers and data entry areas", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 60, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Offices", + "ventilation_secondary_space_type": "Conference rooms", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 50, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Spaces", + "ventilation_secondary_space_type": "Corridors and utilities", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.05, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Spaces", + "ventilation_secondary_space_type": "Public restrooms, cfm/wc or cfm/urinal", + "ventilation_rate_occupant": 50, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Spaces", + "ventilation_secondary_space_type": "Locker and dressing rooms", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.5, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Spaces", + "ventilation_secondary_space_type": "Smoking lounge", + "ventilation_rate_occupant": 60, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 70, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Spaces", + "ventilation_secondary_space_type": "Elevators", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 1, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", + "ventilation_secondary_space_type": "Basement and street", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.3, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 30, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", + "ventilation_secondary_space_type": "Upper floors", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.2, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", + "ventilation_secondary_space_type": "Storage rooms", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.15, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 15, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", + "ventilation_secondary_space_type": "Dressing rooms", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.2, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", + "ventilation_secondary_space_type": "Malls and arcades", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.2, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", + "ventilation_secondary_space_type": "Shipping and receiving", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.15, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", + "ventilation_secondary_space_type": "Warehouses", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.05, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 5, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", + "ventilation_secondary_space_type": "Smoking lounge", + "ventilation_rate_occupant": 60, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 70, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Specialty Shops", + "ventilation_secondary_space_type": "Barber", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Specialty Shops", + "ventilation_secondary_space_type": "Beauty", + "ventilation_rate_occupant": 25, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Specialty Shops", + "ventilation_secondary_space_type": "Reducing salons", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Specialty Shops", + "ventilation_secondary_space_type": "Florists", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 8, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Specialty Shops", + "ventilation_secondary_space_type": "Clothiers, furniture", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.3, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Specialty Shops", + "ventilation_secondary_space_type": "Hardwar, drugs, fabric", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 8, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Specialty Shops", + "ventilation_secondary_space_type": "Supermarkets", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 8, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Specialty Shops", + "ventilation_secondary_space_type": "Pet shops", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 1, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Amusement", + "ventilation_secondary_space_type": "Spectator areas", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 150, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Amusement", + "ventilation_secondary_space_type": "Game rooms", + "ventilation_rate_occupant": 25, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 70, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Amusement", + "ventilation_secondary_space_type": "Ice arenas (playing areas)", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.5, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Amusement", + "ventilation_secondary_space_type": "Swimming pools (pool and deck area)", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.5, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Amusement", + "ventilation_secondary_space_type": "Playing floors (gymnasium)", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 30, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Amusement", + "ventilation_secondary_space_type": "Ballrooms and discos", + "ventilation_rate_occupant": 25, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Amusement", + "ventilation_secondary_space_type": "Bowling alleys (seating areas)", + "ventilation_rate_occupant": 25, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 70, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Theaters", + "ventilation_secondary_space_type": "Ticket booths", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 60, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Theaters", + "ventilation_secondary_space_type": "Lobbies", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 15, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Theaters", + "ventilation_secondary_space_type": "Auditorium", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 150, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Theaters", + "ventilation_secondary_space_type": "Stages, studios", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 70, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Transportation", + "ventilation_secondary_space_type": "Waiting rooms", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Transportation", + "ventilation_secondary_space_type": "Platforms", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Transportation", + "ventilation_secondary_space_type": "Vehicles", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 150, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Workrooms", + "ventilation_secondary_space_type": "Meat processing", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Workrooms", + "ventilation_secondary_space_type": "Photo studios", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Workrooms", + "ventilation_secondary_space_type": "Darkrooms", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.5, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Workrooms", + "ventilation_secondary_space_type": "Pharmacy", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Workrooms", + "ventilation_secondary_space_type": "Bank vaults", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 5, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Workrooms", + "ventilation_secondary_space_type": "Duplicating, printing", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.5, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Education", + "ventilation_secondary_space_type": "Classroom", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 50, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Education", + "ventilation_secondary_space_type": "Laboratories", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 30, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Education", + "ventilation_secondary_space_type": "Training shop", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 30, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Education", + "ventilation_secondary_space_type": "Music rooms", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 50, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Education", + "ventilation_secondary_space_type": "Libraries", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Education", + "ventilation_secondary_space_type": "Locker rooms", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.5, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Education", + "ventilation_secondary_space_type": "Corridors", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.1, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Education", + "ventilation_secondary_space_type": "Auditoriums", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 150, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Education", + "ventilation_secondary_space_type": "Smoking lounge", + "ventilation_rate_occupant": 60, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 710, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", + "ventilation_secondary_space_type": "Patient rooms", + "ventilation_rate_occupant": 25, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", + "ventilation_secondary_space_type": "Medical procedure", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", + "ventilation_secondary_space_type": "Operating rooms", + "ventilation_rate_occupant": 30, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", + "ventilation_secondary_space_type": "Recovery and ICU", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", + "ventilation_secondary_space_type": "Autopsy rooms", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.5, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", + "ventilation_secondary_space_type": "Physical therapy", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Correctional Facilties", + "ventilation_secondary_space_type": "Cells", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Correctional Facilties", + "ventilation_secondary_space_type": "Dining halls", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Correctional Facilties", + "ventilation_secondary_space_type": "Guard stations", + "ventilation_rate_occupant": 15, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "None", + "ventilation_secondary_space_type": "None", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2004.csv b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2004.csv index d2db97a84d..b79b879712 100644 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2004.csv +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2004.csv @@ -1,4 +1,4 @@ -ventilation_primary_space_type,ventilation_secondary_space_type,ventilation_per_person,ventilation_per_person_unit,ventilation_per_area,ventilation_per_area_unit,occupancy_per_area,occupancy_per_area_unit,air_class,os,annotation +ventilation_primary_space_type,ventilation_secondary_space_type,ventilation_rate_occupant,ventilation_rate_occupant_unit,ventilation_rate_area,ventilation_rate_area_unit,occupancy_per_area,occupancy_per_area_unit,air_class,os,annotation Correctional Facilities,Cell,5,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, Correctional Facilities,Day room,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, Correctional Facilities,Guard stations,5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,, @@ -62,3 +62,4 @@ Sports and Entertainment,Bowling alley (seating),10,cfm/person,0.12,cfm/ft2,40,p Sports and Entertainment,Gambling casinos,7.5,cfm/person,0.18,cfm/ft2,120,ppl/1000 ft2,1,, Sports and Entertainment,Game arcades,7.5,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, Sports and Entertainment,"Stages, studios",10,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, +None,None,0,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,,, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2004.json b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2004.json index 7801abf6d5..ae00016844 100644 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2004.json +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2004.json @@ -2,10 +2,10 @@ { "ventilation_primary_space_type": "Correctional Facilities", "ventilation_secondary_space_type": "Cell", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 25, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -15,10 +15,10 @@ { "ventilation_primary_space_type": "Correctional Facilities", "ventilation_secondary_space_type": "Day room", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 30, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -28,10 +28,10 @@ { "ventilation_primary_space_type": "Correctional Facilities", "ventilation_secondary_space_type": "Guard stations", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 15, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -41,10 +41,10 @@ { "ventilation_primary_space_type": "Correctional Facilities", "ventilation_secondary_space_type": "Booking/waiting", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 50, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -54,10 +54,10 @@ { "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Daycare (through age 4)", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 25, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -67,10 +67,10 @@ { "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Classrooms (ages 5-8)", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 25, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -80,10 +80,10 @@ { "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Classrooms (age 9 plus)", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 35, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -93,10 +93,10 @@ { "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Lecture classroom", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 65, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -106,10 +106,10 @@ { "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Lecture hall (fixed seats)", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 150, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -119,10 +119,10 @@ { "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Art classroom", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -132,10 +132,10 @@ { "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Science laboratories", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 25, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": null, @@ -145,10 +145,10 @@ { "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Wood/metal shop", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -158,10 +158,10 @@ { "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Computer lab", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 25, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -171,10 +171,10 @@ { "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Media center", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 25, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -184,10 +184,10 @@ { "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Music/theater/dance", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 35, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -197,10 +197,10 @@ { "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Multi-use assembly", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 100, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -210,10 +210,10 @@ { "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Restaurant dining rooms", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 70, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -223,10 +223,10 @@ { "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 100, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -236,10 +236,10 @@ { "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Bars, cocktail lounges", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 100, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -249,10 +249,10 @@ { "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Conference/meeting", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 50, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -262,10 +262,10 @@ { "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", - "ventilation_per_person": null, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": null, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": null, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -275,10 +275,10 @@ { "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", - "ventilation_per_person": null, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": null, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": null, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -288,10 +288,10 @@ { "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 10, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -301,10 +301,10 @@ { "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Barracks sleeping areas", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -314,10 +314,10 @@ { "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies/prefunction", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 30, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -327,10 +327,10 @@ { "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Multi-purpose assembly", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 120, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -340,10 +340,10 @@ { "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 5, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -353,10 +353,10 @@ { "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Reception areas", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -366,10 +366,10 @@ { "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Telephone/data entry", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 60, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -379,10 +379,10 @@ { "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Main entry lobbies", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 10, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -392,10 +392,10 @@ { "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Bank vaults/safe deposit", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 5, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -405,10 +405,10 @@ { "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Computer (not printing)", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 4, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -418,10 +418,10 @@ { "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Pharmacy (prep. area)", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 10, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -431,10 +431,10 @@ { "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Photo studios", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 10, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -444,10 +444,10 @@ { "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Shipping/receiving", - "ventilation_per_person": null, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": null, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": null, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -457,10 +457,10 @@ { "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Transportation waiting", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 100, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -470,10 +470,10 @@ { "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Warehouses", - "ventilation_per_person": null, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": null, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": null, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -483,10 +483,10 @@ { "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Auditorium seating area", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 150, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -496,10 +496,10 @@ { "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Places of religious workshop", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 120, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -509,10 +509,10 @@ { "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Courtrooms", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 70, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -522,10 +522,10 @@ { "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Legislative chambers", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 50, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -535,10 +535,10 @@ { "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Libraries", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 10, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -548,10 +548,10 @@ { "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Lobbies", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 150, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -561,10 +561,10 @@ { "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Museums (children's)", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 40, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -574,10 +574,10 @@ { "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Museums/galleries", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 40, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -587,10 +587,10 @@ { "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Sales (except as below)", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 15, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -600,10 +600,10 @@ { "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Mall common areas", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 40, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -613,10 +613,10 @@ { "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Barber shop", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 25, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -626,10 +626,10 @@ { "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Beauty and nail salons", - "ventilation_per_person": 20, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 25, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -639,10 +639,10 @@ { "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Pet shops (animal areas)", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 10, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -652,10 +652,10 @@ { "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Supermarket", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 8, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -665,10 +665,10 @@ { "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Coin-operated laundries", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -678,10 +678,10 @@ { "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Sports arena (play area)", - "ventilation_per_person": null, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.3, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": null, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.3, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": null, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -691,10 +691,10 @@ { "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Gym, stadium (play area)", - "ventilation_per_person": null, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.3, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": null, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.3, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 30, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -704,10 +704,10 @@ { "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Spectator areas", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 150, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -717,10 +717,10 @@ { "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Swimming (pool & deck)", - "ventilation_per_person": null, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.48, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": null, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.48, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": null, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -730,10 +730,10 @@ { "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Disco/dance floors", - "ventilation_per_person": 20, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 100, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -743,10 +743,10 @@ { "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Health club/aerobics room", - "ventilation_per_person": 20, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 40, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -756,10 +756,10 @@ { "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Health club/weight rooms", - "ventilation_per_person": 20, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 10, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -769,10 +769,10 @@ { "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Bowling alley (seating)", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 40, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -782,10 +782,10 @@ { "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Gambling casinos", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 120, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -795,10 +795,10 @@ { "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Game arcades", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -808,14 +808,27 @@ { "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Stages, studios", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 70, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, "os": null, "annotation": "" + }, + { + "ventilation_primary_space_type": "None", + "ventilation_secondary_space_type": "None", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" } ] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2007.csv b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2007.csv new file mode 100644 index 0000000000..117325f577 --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2007.csv @@ -0,0 +1,76 @@ +ventilation_primary_space_type,ventilation_secondary_space_type,ventilation_rate_occupant,ventilation_rate_occupant_unit,ventilation_rate_area,ventilation_rate_area_unit,occupancy_per_area,occupancy_per_area_unit,air_class,os,annotation +Correctional Facilities,Cell,5,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, +Correctional Facilities,Day room,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, +Correctional Facilities,Guard stations,5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,, +Correctional Facilities,Booking/waiting,7.5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,2,, +Educational Facilities,Daycare (through age 4),10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, +Educational Facilities,Daycare sickroom,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,3,, +Educational Facilities,Classrooms (ages 5-8),10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, +Educational Facilities,Classrooms (age 9 plus),10,cfm/person,0.12,cfm/ft2,35,ppl/1000 ft2,1,, +Educational Facilities,Lecture classroom,7.5,cfm/person,0.06,cfm/ft2,65,ppl/1000 ft2,1,, +Educational Facilities,Lecture hall (fixed seats),7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, +Educational Facilities,Art classroom,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, +Educational Facilities,Science laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, +Educational Facilities,University/college laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, +Educational Facilities,Wood/metal shop,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, +Educational Facilities,Computer lab,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, +Educational Facilities,Media center,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, +Educational Facilities,Music/theater/dance,10,cfm/person,0.06,cfm/ft2,35,ppl/1000 ft2,1,, +Educational Facilities,Multi-use assembly,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, +Food and Beverage Service,Restaurant dining rooms,7.5,cfm/person,0.18,cfm/ft2,70,ppl/1000 ft2,2,, +Food and Beverage Service,Cafeteria/fast food dining,7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, +Food and Beverage Service,"Bars, cocktail lounges",7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, +General,Break rooms,5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,1,, +General,Coffee stations,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, +General,Conference/meeting,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, +General,Corridors,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, +General,Storage rooms,0,cfm/person,0.12,cfm/ft2,0,ppl/1000 ft2,1,, +"Hotels, Motels, Resorts, Dormitories",Bedroom/living Room,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,, +"Hotels, Motels, Resorts, Dormitories",Barracks sleeping areas,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, +"Hotels, Motels, Resorts, Dormitories","Laundry rooms, central",5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,2,, +"Hotels, Motels, Resorts, Dormitories",Laundry rooms within dwelling units,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, +"Hotels, Motels, Resorts, Dormitories",Lobbies/prefunction,7.5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, +"Hotels, Motels, Resorts, Dormitories",Multipurpose assembly,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,, +Office Buildings,Office space,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1,, +Office Buildings,Reception areas,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, +Office Buildings,Telephone/data entry,5,cfm/person,0.06,cfm/ft2,60,ppl/1000 ft2,1,, +Office Buildings,Main entry lobbies,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,, +Miscellaneous Spaces,Bank vaults/safe deposit,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,2,, +Miscellaneous Spaces,Computer (not printing),5,cfm/person,0.06,cfm/ft2,4,ppl/1000 ft2,1,, +Miscellaneous Spaces,Electrical equipment rooms,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, +Miscellaneous Spaces,Elevator machine rooms,0,cfm/person,0.12,cfm/ft2,0,ppl/1000 ft2,1,, +Miscellaneous Spaces,Pharmacy (prep. area),5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, +Miscellaneous Spaces,Photo studios,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, +Miscellaneous Spaces,Shipping/receiving,0,cfm/person,0.12,cfm/ft2,0,ppl/1000 ft2,1,, +Miscellaneous Spaces,Telephone closets,0,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,1,, +Miscellaneous Spaces,Transportation waiting,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, +Miscellaneous Spaces,Warehouses,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,2,, +Public Assembly Spaces,Auditorium seating area,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, +Public Assembly Spaces,Places of religious workshop,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,, +Public Assembly Spaces,Courtrooms,5,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, +Public Assembly Spaces,Legislative chambers,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, +Public Assembly Spaces,Libraries,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, +Public Assembly Spaces,Lobbies,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, +Public Assembly Spaces,Museums (children�s),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, +Public Assembly Spaces,Museums/galleries,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, +Residential,Dwelling unit,5,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, +Residential,Common corridors,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, +Retail,Sales (except as below),7.5,cfm/person,0.12,cfm/ft2,15,ppl/1000 ft2,2,, +Retail,Mall common areas,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, +Retail,Barbershop,7.5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,2,, +Retail,Beauty and nail salons,20,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, +Retail,Pet shops (animal areas),7.5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, +Retail,Supermarket,7.5,cfm/person,0.06,cfm/ft2,8,ppl/1000 ft2,1,, +Retail,Coin-operated laundries,7.5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,2,, +Sports and Entertainment,Sports arena (play area),0,cfm/person,0.3,cfm/ft2,0,ppl/1000 ft2,1,, +Sports and Entertainment,"Gym, stadium (play area)",0,cfm/person,0.3,cfm/ft2,30,ppl/1000 ft2,2,, +Sports and Entertainment,Spectator areas,7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, +Sports and Entertainment,Swimming (pool & deck),0,cfm/person,0.48,cfm/ft2,0,ppl/1000 ft2,2,, +Sports and Entertainment,Disco/dance floors,20,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, +Sports and Entertainment,Health club/aerobics room,20,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,2,, +Sports and Entertainment,Health club/weight rooms,20,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,2,, +Sports and Entertainment,Bowling alley (seating),10,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, +Sports and Entertainment,Gambling casinos,7.5,cfm/person,0.18,cfm/ft2,120,ppl/1000 ft2,1,, +Sports and Entertainment,Game arcades,7.5,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, +Sports and Entertainment,"Stages, studios",10,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, +None,None,0,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,,, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2007.json b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2007.json new file mode 100644 index 0000000000..afea4430f2 --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2007.json @@ -0,0 +1,977 @@ +[ + { + "ventilation_primary_space_type": "Correctional Facilities", + "ventilation_secondary_space_type": "Cell", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Correctional Facilities", + "ventilation_secondary_space_type": "Day room", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 30, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Correctional Facilities", + "ventilation_secondary_space_type": "Guard stations", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 15, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Correctional Facilities", + "ventilation_secondary_space_type": "Booking/waiting", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 50, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Daycare (through age 4)", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Daycare sickroom", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 3, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Classrooms (ages 5-8)", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Classrooms (age 9 plus)", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 35, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Lecture classroom", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 65, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Lecture hall (fixed seats)", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 150, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Art classroom", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Science laboratories", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "University/college laboratories", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Wood/metal shop", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Computer lab", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Media center", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Music/theater/dance", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 35, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Multi-use assembly", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Food and Beverage Service", + "ventilation_secondary_space_type": "Restaurant dining rooms", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 70, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Food and Beverage Service", + "ventilation_secondary_space_type": "Cafeteria/fast food dining", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Food and Beverage Service", + "ventilation_secondary_space_type": "Bars, cocktail lounges", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "General", + "ventilation_secondary_space_type": "Break rooms", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "General", + "ventilation_secondary_space_type": "Coffee stations", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "General", + "ventilation_secondary_space_type": "Conference/meeting", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 50, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "General", + "ventilation_secondary_space_type": "Corridors", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "General", + "ventilation_secondary_space_type": "Storage rooms", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Bedroom/living Room", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Barracks sleeping areas", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Laundry rooms, central", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Laundry rooms within dwelling units", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Lobbies/prefunction", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 30, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Multipurpose assembly", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 120, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Office space", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 5, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Reception areas", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 30, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Telephone/data entry", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 60, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Main entry lobbies", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Bank vaults/safe deposit", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 5, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Computer (not printing)", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 4, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Electrical equipment rooms", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Elevator machine rooms", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Pharmacy (prep. area)", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Photo studios", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Shipping/receiving", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Telephone closets", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Transportation waiting", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Warehouses", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Auditorium seating area", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 150, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Places of religious workshop", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 120, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Courtrooms", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 70, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Legislative chambers", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 50, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Libraries", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Lobbies", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 150, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Museums (children\u00c3\u00af\u00c2\u00bf\u00c2\u00bds)", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Museums/galleries", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Residential", + "ventilation_secondary_space_type": "Dwelling unit", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Residential", + "ventilation_secondary_space_type": "Common corridors", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Sales (except as below)", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 15, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Mall common areas", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Barbershop", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Beauty and nail salons", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Pet shops (animal areas)", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Supermarket", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 8, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Coin-operated laundries", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Sports arena (play area)", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.3, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Gym, stadium (play area)", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.3, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 30, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Spectator areas", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 150, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Swimming (pool & deck)", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.48, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Disco/dance floors", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Health club/aerobics room", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Health club/weight rooms", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Bowling alley (seating)", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Gambling casinos", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 120, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Game arcades", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Stages, studios", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 70, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "None", + "ventilation_secondary_space_type": "None", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2010.csv b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2010.csv new file mode 100644 index 0000000000..c69650b920 --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2010.csv @@ -0,0 +1,80 @@ +ventilation_primary_space_type,ventilation_secondary_space_type,ventilation_rate_occupant,ventilation_rate_occupant_unit,ventilation_rate_area,ventilation_rate_area_unit,occupancy_per_area,occupancy_per_area_unit,air_class,os,annotation +Correctional Facilities,Cell,5,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, +Correctional Facilities,Dayroom,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, +Correctional Facilities,Guard stations,5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,, +Correctional Facilities,Booking/waiting,7.5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,2,, +Educational Facilities,Daycare (through age 4),10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, +Educational Facilities,Daycare sickroom,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,3,, +Educational Facilities,Classrooms (ages 5-8),10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, +Educational Facilities,Classrooms (age 9 plus),10,cfm/person,0.12,cfm/ft2,35,ppl/1000 ft2,1,, +Educational Facilities,Lecture classroom,7.5,cfm/person,0.06,cfm/ft2,65,ppl/1000 ft2,1,, +Educational Facilities,Lecture hall (fixed seats),7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, +Educational Facilities,Art classroom,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, +Educational Facilities,Science laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, +Educational Facilities,University/college laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, +Educational Facilities,Wood/metal shop,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, +Educational Facilities,Computer lab,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, +Educational Facilities,Media center,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, +Educational Facilities,Music/theater/dance,10,cfm/person,0.06,cfm/ft2,35,ppl/1000 ft2,1,, +Educational Facilities,Multi-use assembly,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, +Food and Beverage Service,Restaurant dining rooms,7.5,cfm/person,0.18,cfm/ft2,70,ppl/1000 ft2,2,, +Food and Beverage Service,Cafeteria/fast food dining,7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, +Food and Beverage Service,"Bars, cocktail lounges",7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, +Food and Beverage Service,Kitchen (cooking),7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2,, +General,Break rooms,5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,1,, +General,Coffee stations,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, +General,Conference/meeting,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, +General,Corridors,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, +General,Occupiable storage rooms for liquids or gels,5,cfm/person,0.12,cfm/ft2,2,ppl/1000 ft2,2,, +"Hotels, Motels, Resorts, Dormitories",Bedroom/living Room,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,, +"Hotels, Motels, Resorts, Dormitories",Barracks sleeping areas,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, +"Hotels, Motels, Resorts, Dormitories","Laundry rooms, central",5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,2,, +"Hotels, Motels, Resorts, Dormitories",Laundry rooms within dwelling units,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, +"Hotels, Motels, Resorts, Dormitories",Lobbies/prefunction,7.5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, +"Hotels, Motels, Resorts, Dormitories",Multipurpose assembly,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,, +Office Buildings,Breakrooms,5,cfm/person,0.12,cfm/ft2,50,ppl/1000 ft2,1,, +Office Buildings,Main entry lobbies,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,, +Office Buildings,Occupiable storage rooms for dry materials,5,cfm/person,0.06,cfm/ft2,2,ppl/1000 ft2,1,, +Office Buildings,Office space,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1,, +Office Buildings,Reception areas,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, +Office Buildings,Telephone/data entry,5,cfm/person,0.06,cfm/ft2,60,ppl/1000 ft2,1,, +Miscellaneous Spaces,Bank vaults/safe deposit,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,2,, +Miscellaneous Spaces,Banks or bank lobbies,7.5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,, +Miscellaneous Spaces,Computer (not printing),5,cfm/person,0.06,cfm/ft2,4,ppl/1000 ft2,1,, +Miscellaneous Spaces,General manufacturing (excludes heavy industrial and processes using chemicals),10,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,3,, +Miscellaneous Spaces,Pharmacy (prep. area),5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, +Miscellaneous Spaces,Photo studios,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, +Miscellaneous Spaces,Shipping/receiving,10,cfm/person,0.12,cfm/ft2,2,ppl/1000 ft2,2,, +Miscellaneous Spaces,"Sorting, packing, light assembly",7.5,cfm/person,0.12,cfm/ft2,7,ppl/1000 ft2,2,, +Miscellaneous Spaces,Telephone closets,0,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,1,, +Miscellaneous Spaces,Transportation waiting,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, +Miscellaneous Spaces,Warehouses,10,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,2,, +Public Assembly Spaces,Auditorium seating area,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, +Public Assembly Spaces,Places of religious workshop,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,, +Public Assembly Spaces,Courtrooms,5,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, +Public Assembly Spaces,Legislative chambers,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, +Public Assembly Spaces,Libraries,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, +Public Assembly Spaces,Lobbies,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, +Public Assembly Spaces,Museums (children�s),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, +Public Assembly Spaces,Museums/galleries,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, +Residential,Dwelling unit,5,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, +Residential,Common corridors,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, +Retail,Sales (except as below),7.5,cfm/person,0.12,cfm/ft2,15,ppl/1000 ft2,2,, +Retail,Mall common areas,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, +Retail,Barbershop,7.5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,2,, +Retail,Beauty and nail salons,20,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, +Retail,Pet shops (animal areas),7.5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, +Retail,Supermarket,7.5,cfm/person,0.06,cfm/ft2,8,ppl/1000 ft2,1,, +Retail,Coin-operated laundries,7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2,, +Sports and Entertainment,Sports arena (play area),0,cfm/person,0.3,cfm/ft2,0,ppl/1000 ft2,1,, +Sports and Entertainment,"Gym, stadium (play area)",0,cfm/person,0.3,cfm/ft2,30,ppl/1000 ft2,2,, +Sports and Entertainment,Spectator areas,7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, +Sports and Entertainment,Swimming (pool & deck),0,cfm/person,0.48,cfm/ft2,0,ppl/1000 ft2,2,, +Sports and Entertainment,Disco/dance floors,20,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,2,, +Sports and Entertainment,Health club/aerobics room,20,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,2,, +Sports and Entertainment,Health club/weight rooms,20,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,2,, +Sports and Entertainment,Bowling alley (seating),10,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, +Sports and Entertainment,Gambling casinos,7.5,cfm/person,0.18,cfm/ft2,120,ppl/1000 ft2,1,, +Sports and Entertainment,Game arcades,7.5,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, +Sports and Entertainment,"Stages, studios",10,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, +None,None,0,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,,, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2010.json b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2010.json new file mode 100644 index 0000000000..2ac91560fe --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2010.json @@ -0,0 +1,1029 @@ +[ + { + "ventilation_primary_space_type": "Correctional Facilities", + "ventilation_secondary_space_type": "Cell", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Correctional Facilities", + "ventilation_secondary_space_type": "Dayroom", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 30, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Correctional Facilities", + "ventilation_secondary_space_type": "Guard stations", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 15, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Correctional Facilities", + "ventilation_secondary_space_type": "Booking/waiting", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 50, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Daycare (through age 4)", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Daycare sickroom", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 3, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Classrooms (ages 5-8)", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Classrooms (age 9 plus)", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 35, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Lecture classroom", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 65, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Lecture hall (fixed seats)", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 150, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Art classroom", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Science laboratories", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "University/college laboratories", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Wood/metal shop", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Computer lab", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Media center", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Music/theater/dance", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 35, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Multi-use assembly", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Food and Beverage Service", + "ventilation_secondary_space_type": "Restaurant dining rooms", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 70, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Food and Beverage Service", + "ventilation_secondary_space_type": "Cafeteria/fast food dining", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Food and Beverage Service", + "ventilation_secondary_space_type": "Bars, cocktail lounges", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Food and Beverage Service", + "ventilation_secondary_space_type": "Kitchen (cooking)", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "General", + "ventilation_secondary_space_type": "Break rooms", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "General", + "ventilation_secondary_space_type": "Coffee stations", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "General", + "ventilation_secondary_space_type": "Conference/meeting", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 50, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "General", + "ventilation_secondary_space_type": "Corridors", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "General", + "ventilation_secondary_space_type": "Occupiable storage rooms for liquids or gels", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 2, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Bedroom/living Room", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Barracks sleeping areas", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Laundry rooms, central", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Laundry rooms within dwelling units", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Lobbies/prefunction", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 30, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Multipurpose assembly", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 120, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Breakrooms", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 50, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Main entry lobbies", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Occupiable storage rooms for dry materials", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 2, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Office space", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 5, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Reception areas", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 30, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Telephone/data entry", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 60, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Bank vaults/safe deposit", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 5, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Banks or bank lobbies", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 15, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Computer (not printing)", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 4, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "General manufacturing (excludes heavy industrial and processes using chemicals)", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 7, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 3, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Pharmacy (prep. area)", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Photo studios", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Shipping/receiving", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 2, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Sorting, packing, light assembly", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 7, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Telephone closets", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Transportation waiting", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Warehouses", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Auditorium seating area", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 150, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Places of religious workshop", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 120, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Courtrooms", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 70, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Legislative chambers", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 50, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Libraries", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Lobbies", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 150, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Museums (children\u00c3\u00af\u00c2\u00bf\u00c2\u00bds)", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Museums/galleries", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Residential", + "ventilation_secondary_space_type": "Dwelling unit", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Residential", + "ventilation_secondary_space_type": "Common corridors", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Sales (except as below)", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 15, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Mall common areas", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Barbershop", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Beauty and nail salons", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Pet shops (animal areas)", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Supermarket", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 8, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Coin-operated laundries", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Sports arena (play area)", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.3, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Gym, stadium (play area)", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.3, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 30, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Spectator areas", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 150, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Swimming (pool & deck)", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.48, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Disco/dance floors", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Health club/aerobics room", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Health club/weight rooms", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Bowling alley (seating)", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Gambling casinos", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 120, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Game arcades", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Stages, studios", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 70, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "None", + "ventilation_secondary_space_type": "None", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2013.csv b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2013.csv new file mode 100644 index 0000000000..712c97498b --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2013.csv @@ -0,0 +1,80 @@ +ventilation_primary_space_type,ventilation_secondary_space_type,ventilation_rate_occupant,ventilation_rate_occupant_unit,ventilation_rate_area,ventilation_rate_area_unit,occupancy_per_area,occupancy_per_area_unit,air_class,os,annotation +Correctional Facilities,Cell,5,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, +Correctional Facilities,Dayroom,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, +Correctional Facilities,Guard stations,5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,, +Correctional Facilities,Booking/waiting,7.5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,2,, +Educational Facilities,Daycare (through age 4),10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, +Educational Facilities,Daycare sickroom,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,3,, +Educational Facilities,Classrooms (ages 5-8),10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, +Educational Facilities,Classrooms (age 9 plus),10,cfm/person,0.12,cfm/ft2,35,ppl/1000 ft2,1,, +Educational Facilities,Lecture classroom,7.5,cfm/person,0.06,cfm/ft2,65,ppl/1000 ft2,1,, +Educational Facilities,Lecture hall (fixed seats),7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, +Educational Facilities,Art classroom,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, +Educational Facilities,Science laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, +Educational Facilities,University/college laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, +Educational Facilities,Wood/metal shop,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, +Educational Facilities,Computer lab,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, +Educational Facilities,Media center,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, +Educational Facilities,Music/theater/dance,10,cfm/person,0.06,cfm/ft2,35,ppl/1000 ft2,1,, +Educational Facilities,Multiuse assembly,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, +Food and Beverage Service,Restaurant dining rooms,7.5,cfm/person,0.18,cfm/ft2,70,ppl/1000 ft2,2,, +Food and Beverage Service,Cafeteria/fast-food dining,7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, +Food and Beverage Service,"Bars, cocktail lounges",7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, +Food and Beverage Service,Kitchen (cooking),7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2,, +General,Break rooms,5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,1,, +General,Coffee stations,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, +General,Conference/meeting,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, +General,Corridors,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, +General,Occupiable storage rooms for liquids or gels,5,cfm/person,0.12,cfm/ft2,2,ppl/1000 ft2,2,, +"Hotels, Motels, Resorts, Dormitories",Bedroom/living Room,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,, +"Hotels, Motels, Resorts, Dormitories",Barracks sleeping areas,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, +"Hotels, Motels, Resorts, Dormitories","Laundry rooms, central",5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,2,, +"Hotels, Motels, Resorts, Dormitories",Laundry rooms within dwelling units,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, +"Hotels, Motels, Resorts, Dormitories",Lobbies/prefunction,7.5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, +"Hotels, Motels, Resorts, Dormitories",Multipurpose assembly,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,, +Miscellaneous Spaces,Bank vaults/safe deposit,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,2,, +Miscellaneous Spaces,Banks or bank lobbies,7.5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,, +Miscellaneous Spaces,Computer (not printing),5,cfm/person,0.06,cfm/ft2,4,ppl/1000 ft2,1,, +Miscellaneous Spaces,Freezer and refrigerated spaces (<50�F),10,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,2,, +Miscellaneous Spaces,General manufacturing (excludes heavy industrial and processes using chemicals),10,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,3,, +Miscellaneous Spaces,Pharmacy (prep. area),5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, +Miscellaneous Spaces,Photo studios,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, +Miscellaneous Spaces,Shipping/receiving,10,cfm/person,0.12,cfm/ft2,2,ppl/1000 ft2,2,, +Miscellaneous Spaces,"Sorting, packing, light assembly",7.5,cfm/person,0.12,cfm/ft2,7,ppl/1000 ft2,2,, +Miscellaneous Spaces,Telephone closets,0,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,1,, +Miscellaneous Spaces,Transportation waiting,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, +Miscellaneous Spaces,Warehouses,10,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,2,, +Office Buildings,Breakrooms,5,cfm/person,0.12,cfm/ft2,50,ppl/1000 ft2,1,, +Office Buildings,Main entry lobbies,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,, +Office Buildings,Occupiable storage rooms for dry materials,5,cfm/person,0.06,cfm/ft2,2,ppl/1000 ft2,1,, +Office Buildings,Office space,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1,, +Office Buildings,Reception areas,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, +Office Buildings,Telephone/data entry,5,cfm/person,0.06,cfm/ft2,60,ppl/1000 ft2,1,, +Public Assembly Spaces,Auditorium seating area,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, +Public Assembly Spaces,Places of religious workshop,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,, +Public Assembly Spaces,Courtrooms,5,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, +Public Assembly Spaces,Legislative chambers,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, +Public Assembly Spaces,Libraries,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, +Public Assembly Spaces,Lobbies,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, +Public Assembly Spaces,Museums (children�s),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, +Public Assembly Spaces,Museums/galleries,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, +Residential,Dwelling unit,5,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, +Residential,Common corridors,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, +Retail,Sales (except as below),7.5,cfm/person,0.12,cfm/ft2,15,ppl/1000 ft2,2,, +Retail,Mall common areas,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, +Retail,Barbershop,7.5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,2,, +Retail,Beauty and nail salons,20,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, +Retail,Pet shops (animal areas),7.5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, +Retail,Supermarket,7.5,cfm/person,0.06,cfm/ft2,8,ppl/1000 ft2,1,, +Retail,Coin-operated laundries,7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2,, +Sports and Entertainment,"Gym, sports arena (play area)",20,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,2,, +Sports and Entertainment,Spectator areas,7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, +Sports and Entertainment,Swimming (pool & deck),0,cfm/person,0.48,cfm/ft2,0,ppl/1000 ft2,2,, +Sports and Entertainment,Disco/dance floors,20,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,2,, +Sports and Entertainment,Health club/aerobics room,20,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,2,, +Sports and Entertainment,Health club/weight rooms,20,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,2,, +Sports and Entertainment,Bowling alley (seating),10,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, +Sports and Entertainment,Gambling casinos,7.5,cfm/person,0.18,cfm/ft2,120,ppl/1000 ft2,1,, +Sports and Entertainment,Game arcades,7.5,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, +Sports and Entertainment,"Stages, studios",10,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, +None,None,0,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,,, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2013.json b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2013.json new file mode 100644 index 0000000000..fe529c3029 --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2013.json @@ -0,0 +1,1029 @@ +[ + { + "ventilation_primary_space_type": "Correctional Facilities", + "ventilation_secondary_space_type": "Cell", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Correctional Facilities", + "ventilation_secondary_space_type": "Dayroom", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 30, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Correctional Facilities", + "ventilation_secondary_space_type": "Guard stations", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 15, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Correctional Facilities", + "ventilation_secondary_space_type": "Booking/waiting", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 50, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Daycare (through age 4)", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Daycare sickroom", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 3, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Classrooms (ages 5-8)", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Classrooms (age 9 plus)", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 35, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Lecture classroom", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 65, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Lecture hall (fixed seats)", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 150, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Art classroom", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Science laboratories", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "University/college laboratories", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Wood/metal shop", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Computer lab", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Media center", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Music/theater/dance", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 35, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Multiuse assembly", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Food and Beverage Service", + "ventilation_secondary_space_type": "Restaurant dining rooms", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 70, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Food and Beverage Service", + "ventilation_secondary_space_type": "Cafeteria/fast-food dining", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Food and Beverage Service", + "ventilation_secondary_space_type": "Bars, cocktail lounges", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Food and Beverage Service", + "ventilation_secondary_space_type": "Kitchen (cooking)", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "General", + "ventilation_secondary_space_type": "Break rooms", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "General", + "ventilation_secondary_space_type": "Coffee stations", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "General", + "ventilation_secondary_space_type": "Conference/meeting", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 50, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "General", + "ventilation_secondary_space_type": "Corridors", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "General", + "ventilation_secondary_space_type": "Occupiable storage rooms for liquids or gels", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 2, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Bedroom/living Room", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Barracks sleeping areas", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Laundry rooms, central", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Laundry rooms within dwelling units", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Lobbies/prefunction", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 30, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Multipurpose assembly", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 120, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Bank vaults/safe deposit", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 5, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Banks or bank lobbies", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 15, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Computer (not printing)", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 4, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Freezer and refrigerated spaces (<50\u00c3\u00af\u00c2\u00bf\u00c2\u00bdF)", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "General manufacturing (excludes heavy industrial and processes using chemicals)", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 7, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 3, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Pharmacy (prep. area)", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Photo studios", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Shipping/receiving", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 2, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Sorting, packing, light assembly", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 7, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Telephone closets", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Transportation waiting", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Warehouses", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Breakrooms", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 50, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Main entry lobbies", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Occupiable storage rooms for dry materials", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 2, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Office space", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 5, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Reception areas", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 30, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Telephone/data entry", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 60, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Auditorium seating area", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 150, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Places of religious workshop", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 120, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Courtrooms", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 70, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Legislative chambers", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 50, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Libraries", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Lobbies", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 150, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Museums (children\u00c3\u00af\u00c2\u00bf\u00c2\u00bds)", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Museums/galleries", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Residential", + "ventilation_secondary_space_type": "Dwelling unit", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Residential", + "ventilation_secondary_space_type": "Common corridors", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Sales (except as below)", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 15, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Mall common areas", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Barbershop", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Beauty and nail salons", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Pet shops (animal areas)", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Supermarket", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 8, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Coin-operated laundries", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Gym, sports arena (play area)", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 7, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Spectator areas", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 150, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Swimming (pool & deck)", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.48, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Disco/dance floors", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Health club/aerobics room", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Health club/weight rooms", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Bowling alley (seating)", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Gambling casinos", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 120, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Game arcades", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Stages, studios", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 70, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "None", + "ventilation_secondary_space_type": "None", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2016.csv b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2016.csv new file mode 100644 index 0000000000..712c97498b --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2016.csv @@ -0,0 +1,80 @@ +ventilation_primary_space_type,ventilation_secondary_space_type,ventilation_rate_occupant,ventilation_rate_occupant_unit,ventilation_rate_area,ventilation_rate_area_unit,occupancy_per_area,occupancy_per_area_unit,air_class,os,annotation +Correctional Facilities,Cell,5,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, +Correctional Facilities,Dayroom,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, +Correctional Facilities,Guard stations,5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,, +Correctional Facilities,Booking/waiting,7.5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,2,, +Educational Facilities,Daycare (through age 4),10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, +Educational Facilities,Daycare sickroom,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,3,, +Educational Facilities,Classrooms (ages 5-8),10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, +Educational Facilities,Classrooms (age 9 plus),10,cfm/person,0.12,cfm/ft2,35,ppl/1000 ft2,1,, +Educational Facilities,Lecture classroom,7.5,cfm/person,0.06,cfm/ft2,65,ppl/1000 ft2,1,, +Educational Facilities,Lecture hall (fixed seats),7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, +Educational Facilities,Art classroom,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, +Educational Facilities,Science laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, +Educational Facilities,University/college laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, +Educational Facilities,Wood/metal shop,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, +Educational Facilities,Computer lab,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, +Educational Facilities,Media center,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, +Educational Facilities,Music/theater/dance,10,cfm/person,0.06,cfm/ft2,35,ppl/1000 ft2,1,, +Educational Facilities,Multiuse assembly,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, +Food and Beverage Service,Restaurant dining rooms,7.5,cfm/person,0.18,cfm/ft2,70,ppl/1000 ft2,2,, +Food and Beverage Service,Cafeteria/fast-food dining,7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, +Food and Beverage Service,"Bars, cocktail lounges",7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, +Food and Beverage Service,Kitchen (cooking),7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2,, +General,Break rooms,5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,1,, +General,Coffee stations,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, +General,Conference/meeting,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, +General,Corridors,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, +General,Occupiable storage rooms for liquids or gels,5,cfm/person,0.12,cfm/ft2,2,ppl/1000 ft2,2,, +"Hotels, Motels, Resorts, Dormitories",Bedroom/living Room,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,, +"Hotels, Motels, Resorts, Dormitories",Barracks sleeping areas,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, +"Hotels, Motels, Resorts, Dormitories","Laundry rooms, central",5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,2,, +"Hotels, Motels, Resorts, Dormitories",Laundry rooms within dwelling units,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, +"Hotels, Motels, Resorts, Dormitories",Lobbies/prefunction,7.5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, +"Hotels, Motels, Resorts, Dormitories",Multipurpose assembly,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,, +Miscellaneous Spaces,Bank vaults/safe deposit,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,2,, +Miscellaneous Spaces,Banks or bank lobbies,7.5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,, +Miscellaneous Spaces,Computer (not printing),5,cfm/person,0.06,cfm/ft2,4,ppl/1000 ft2,1,, +Miscellaneous Spaces,Freezer and refrigerated spaces (<50�F),10,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,2,, +Miscellaneous Spaces,General manufacturing (excludes heavy industrial and processes using chemicals),10,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,3,, +Miscellaneous Spaces,Pharmacy (prep. area),5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, +Miscellaneous Spaces,Photo studios,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, +Miscellaneous Spaces,Shipping/receiving,10,cfm/person,0.12,cfm/ft2,2,ppl/1000 ft2,2,, +Miscellaneous Spaces,"Sorting, packing, light assembly",7.5,cfm/person,0.12,cfm/ft2,7,ppl/1000 ft2,2,, +Miscellaneous Spaces,Telephone closets,0,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,1,, +Miscellaneous Spaces,Transportation waiting,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, +Miscellaneous Spaces,Warehouses,10,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,2,, +Office Buildings,Breakrooms,5,cfm/person,0.12,cfm/ft2,50,ppl/1000 ft2,1,, +Office Buildings,Main entry lobbies,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,, +Office Buildings,Occupiable storage rooms for dry materials,5,cfm/person,0.06,cfm/ft2,2,ppl/1000 ft2,1,, +Office Buildings,Office space,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1,, +Office Buildings,Reception areas,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, +Office Buildings,Telephone/data entry,5,cfm/person,0.06,cfm/ft2,60,ppl/1000 ft2,1,, +Public Assembly Spaces,Auditorium seating area,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, +Public Assembly Spaces,Places of religious workshop,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,, +Public Assembly Spaces,Courtrooms,5,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, +Public Assembly Spaces,Legislative chambers,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, +Public Assembly Spaces,Libraries,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, +Public Assembly Spaces,Lobbies,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, +Public Assembly Spaces,Museums (children�s),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, +Public Assembly Spaces,Museums/galleries,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, +Residential,Dwelling unit,5,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, +Residential,Common corridors,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, +Retail,Sales (except as below),7.5,cfm/person,0.12,cfm/ft2,15,ppl/1000 ft2,2,, +Retail,Mall common areas,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, +Retail,Barbershop,7.5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,2,, +Retail,Beauty and nail salons,20,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, +Retail,Pet shops (animal areas),7.5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, +Retail,Supermarket,7.5,cfm/person,0.06,cfm/ft2,8,ppl/1000 ft2,1,, +Retail,Coin-operated laundries,7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2,, +Sports and Entertainment,"Gym, sports arena (play area)",20,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,2,, +Sports and Entertainment,Spectator areas,7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, +Sports and Entertainment,Swimming (pool & deck),0,cfm/person,0.48,cfm/ft2,0,ppl/1000 ft2,2,, +Sports and Entertainment,Disco/dance floors,20,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,2,, +Sports and Entertainment,Health club/aerobics room,20,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,2,, +Sports and Entertainment,Health club/weight rooms,20,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,2,, +Sports and Entertainment,Bowling alley (seating),10,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, +Sports and Entertainment,Gambling casinos,7.5,cfm/person,0.18,cfm/ft2,120,ppl/1000 ft2,1,, +Sports and Entertainment,Game arcades,7.5,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, +Sports and Entertainment,"Stages, studios",10,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, +None,None,0,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,,, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2016.json b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2016.json new file mode 100644 index 0000000000..fe529c3029 --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2016.json @@ -0,0 +1,1029 @@ +[ + { + "ventilation_primary_space_type": "Correctional Facilities", + "ventilation_secondary_space_type": "Cell", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Correctional Facilities", + "ventilation_secondary_space_type": "Dayroom", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 30, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Correctional Facilities", + "ventilation_secondary_space_type": "Guard stations", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 15, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Correctional Facilities", + "ventilation_secondary_space_type": "Booking/waiting", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 50, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Daycare (through age 4)", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Daycare sickroom", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 3, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Classrooms (ages 5-8)", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Classrooms (age 9 plus)", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 35, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Lecture classroom", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 65, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Lecture hall (fixed seats)", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 150, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Art classroom", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Science laboratories", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "University/college laboratories", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Wood/metal shop", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Computer lab", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Media center", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Music/theater/dance", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 35, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Educational Facilities", + "ventilation_secondary_space_type": "Multiuse assembly", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Food and Beverage Service", + "ventilation_secondary_space_type": "Restaurant dining rooms", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 70, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Food and Beverage Service", + "ventilation_secondary_space_type": "Cafeteria/fast-food dining", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Food and Beverage Service", + "ventilation_secondary_space_type": "Bars, cocktail lounges", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Food and Beverage Service", + "ventilation_secondary_space_type": "Kitchen (cooking)", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "General", + "ventilation_secondary_space_type": "Break rooms", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "General", + "ventilation_secondary_space_type": "Coffee stations", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "General", + "ventilation_secondary_space_type": "Conference/meeting", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 50, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "General", + "ventilation_secondary_space_type": "Corridors", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "General", + "ventilation_secondary_space_type": "Occupiable storage rooms for liquids or gels", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 2, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Bedroom/living Room", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Barracks sleeping areas", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Laundry rooms, central", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Laundry rooms within dwelling units", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Lobbies/prefunction", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 30, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", + "ventilation_secondary_space_type": "Multipurpose assembly", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 120, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Bank vaults/safe deposit", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 5, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Banks or bank lobbies", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 15, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Computer (not printing)", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 4, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Freezer and refrigerated spaces (<50\u00c3\u00af\u00c2\u00bf\u00c2\u00bdF)", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "General manufacturing (excludes heavy industrial and processes using chemicals)", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 7, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 3, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Pharmacy (prep. area)", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Photo studios", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Shipping/receiving", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 2, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Sorting, packing, light assembly", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 7, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Telephone closets", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Transportation waiting", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Miscellaneous Spaces", + "ventilation_secondary_space_type": "Warehouses", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Breakrooms", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 50, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Main entry lobbies", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Occupiable storage rooms for dry materials", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 2, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Office space", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 5, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Reception areas", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 30, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Office Buildings", + "ventilation_secondary_space_type": "Telephone/data entry", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 60, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Auditorium seating area", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 150, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Places of religious workshop", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 120, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Courtrooms", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 70, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Legislative chambers", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 50, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Libraries", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Lobbies", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 150, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Museums (children\u00c3\u00af\u00c2\u00bf\u00c2\u00bds)", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Public Assembly Spaces", + "ventilation_secondary_space_type": "Museums/galleries", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Residential", + "ventilation_secondary_space_type": "Dwelling unit", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Residential", + "ventilation_secondary_space_type": "Common corridors", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Sales (except as below)", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 15, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Mall common areas", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Barbershop", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Beauty and nail salons", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 25, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Pet shops (animal areas)", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Supermarket", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 8, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Retail", + "ventilation_secondary_space_type": "Coin-operated laundries", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Gym, sports arena (play area)", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 7, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Spectator areas", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 150, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Swimming (pool & deck)", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.48, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Disco/dance floors", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 100, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Health club/aerobics room", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Health club/weight rooms", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 10, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 2, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Bowling alley (seating)", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 40, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Gambling casinos", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 120, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Game arcades", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 20, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "Sports and Entertainment", + "ventilation_secondary_space_type": "Stages, studios", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 70, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": 1, + "os": null, + "annotation": "" + }, + { + "ventilation_primary_space_type": "None", + "ventilation_secondary_space_type": "None", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.csv b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.csv index ba7be90ba7..cfa1e51ef3 100644 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.csv +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.csv @@ -1,4 +1,4 @@ -ventilation_primary_space_type,ventilation_secondary_space_type,ventilation_per_person,ventilation_per_person_unit,ventilation_per_area,ventilation_per_area_unit,occupancy_per_area,occupancy_per_area_unit,air_class,os,annotation +ventilation_primary_space_type,ventilation_secondary_space_type,ventilation_rate_occupant,ventilation_rate_occupant_unit,ventilation_rate_area,ventilation_rate_area_unit,occupancy_per_area,occupancy_per_area_unit,air_class,os,annotation Animal Facilities,Animal exam room (veterinary office),10,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2,, Animal Facilities,Animal imaging (MRI/CT/PET),10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, Animal Facilities,Animal operating rooms,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, @@ -36,7 +36,7 @@ Food and Beverage Service,Restaurant dining rooms,7.5,cfm/person,0.18,cfm/ft2,70 "Food and Beverage Service, General",Break rooms,5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,1,yes, "Food and Beverage Service, General",Coffee stations,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,yes, "Food and Beverage Service, General",Conference/meeting,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,yes, -"Food and Beverage Service, General",Corridors,,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,1,yes, +"Food and Beverage Service, General",Corridors,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,yes, "Food and Beverage Service, General",Occupiable storage rooms for liquids or gels,5,cfm/person,0.12,cfm/ft2,2,ppl/1000 ft2,2,, "Hotels, Motels, Resorts, Dormitories",Barracks sleeping areas,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,yes, "Hotels, Motels, Resorts, Dormitories",Bedroom/living room,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,yes, @@ -47,16 +47,16 @@ Food and Beverage Service,Restaurant dining rooms,7.5,cfm/person,0.18,cfm/ft2,70 Miscellaneous Spaces,Banks or bank lobbies,7.5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,yes, Miscellaneous Spaces,Bank vaults/safe deposit,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,2,yes, Miscellaneous Spaces,Computer (not printing),5,cfm/person,0.06,cfm/ft2,4,ppl/1000 ft2,1,yes, -Miscellaneous Spaces,Freezer and refrigerated spaces (<50�F [10�C]),10,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,2,, +Miscellaneous Spaces,Freezer and refrigerated spaces (<50�F [10�C]),10,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,2,, Miscellaneous Spaces,Manufacturing where hazardous materials are not used,10,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,2,, Miscellaneous Spaces,Manufacturing where hazardous materials are used (excludes heavy industrial and chemical processes),10,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,3,, Miscellaneous Spaces,Pharmacy (prep. area),5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, Miscellaneous Spaces,Photo studios,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, Miscellaneous Spaces,Shipping/receiving,10,cfm/person,0.12,cfm/ft2,2,ppl/1000 ft2,2,, Miscellaneous Spaces,"Sorting, packing, light assembly",7.5,cfm/person,0.12,cfm/ft2,7,ppl/1000 ft2,2,, -Miscellaneous Spaces,Telephone closets,,cfm/person,0,cfm/ft2,,ppl/1000 ft2,1,, +Miscellaneous Spaces,Telephone closets,0,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,1,, Miscellaneous Spaces,Transportation waiting,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,yes, -Miscellaneous Spaces,Warehouses,10,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,2,, +Miscellaneous Spaces,Warehouses,10,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,2,, Office Buildings,Breakrooms,5,cfm/person,0.12,cfm/ft2,50,ppl/1000 ft2,1,, Office Buildings,Main entry lobbies,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,yes, Office Buildings,Occupiable storage rooms for dry materials,5,cfm/person,0.06,cfm/ft2,2,ppl/1000 ft2,1,, @@ -70,7 +70,7 @@ Outpatient Health Care Facilities,General examination room,7.5,cfm/person,0.12,c Outpatient Health Care Facilities,Other dental treatment areas,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1,, Outpatient Health Care Facilities,Physical therapy exercise area,20,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,2,, Outpatient Health Care Facilities,Physical therapy individual room,10,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, -Outpatient Health Care Facilities,Physical therapeutic pool area,,cfm/person,0.48,cfm/ft2,,ppl/1000 ft2,2,, +Outpatient Health Care Facilities,Physical therapeutic pool area,0,cfm/person,0.48,cfm/ft2,0,ppl/1000 ft2,2,, Outpatient Health Care Facilities,Prosthetics and orthotics room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, Outpatient Health Care Facilities,Psychiatric consultation room,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, Outpatient Health Care Facilities,Psychiatric examination room,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, @@ -105,6 +105,7 @@ Sports and Entertainment,Health club/aerobics room,20,cfm/person,0.06,cfm/ft2,40 Sports and Entertainment,Health club/weight rooms,20,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,2,, Sports and Entertainment,Spectator areas,7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,yes, Sports and Entertainment,"Stages, studios",10,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,yes, -Sports and Entertainment,Swimming (pool and deck),,cfm/person,0.48,cfm/ft2,,ppl/1000 ft2,2,, -Transient Residential,Common corridors,,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,1,yes, -Transient Residential,Dwelling unit,5,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,1,yes, +Sports and Entertainment,Swimming (pool and deck),0,cfm/person,0.48,cfm/ft2,0,ppl/1000 ft2,2,, +Transient Residential,Common corridors,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,yes, +Transient Residential,Dwelling unit,5,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,yes, +None,None,0,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,,, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.json b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.json index 853a4b3469..aa61220a0a 100644 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.json +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.json @@ -2,10 +2,10 @@ { "ventilation_primary_space_type": "Animal Facilities", "ventilation_secondary_space_type": "Animal exam room (veterinary office)", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -15,10 +15,10 @@ { "ventilation_primary_space_type": "Animal Facilities", "ventilation_secondary_space_type": "Animal imaging (MRI/CT/PET)", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 3, @@ -28,10 +28,10 @@ { "ventilation_primary_space_type": "Animal Facilities", "ventilation_secondary_space_type": "Animal operating rooms", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 3, @@ -41,10 +41,10 @@ { "ventilation_primary_space_type": "Animal Facilities", "ventilation_secondary_space_type": "Animal postoperative recovery room", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 3, @@ -54,10 +54,10 @@ { "ventilation_primary_space_type": "Animal Facilities", "ventilation_secondary_space_type": "Animal preparation rooms", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 3, @@ -67,10 +67,10 @@ { "ventilation_primary_space_type": "Animal Facilities", "ventilation_secondary_space_type": "Animal procedure room", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 3, @@ -80,10 +80,10 @@ { "ventilation_primary_space_type": "Animal Facilities", "ventilation_secondary_space_type": "Animal surgery scrub", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 3, @@ -93,10 +93,10 @@ { "ventilation_primary_space_type": "Animal Facilities", "ventilation_secondary_space_type": "Large-animal holding room", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 3, @@ -106,10 +106,10 @@ { "ventilation_primary_space_type": "Animal Facilities", "ventilation_secondary_space_type": "Necropsy", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 3, @@ -119,10 +119,10 @@ { "ventilation_primary_space_type": "Animal Facilities", "ventilation_secondary_space_type": "Small-animal-cage room (static cages)", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 3, @@ -132,10 +132,10 @@ { "ventilation_primary_space_type": "Animal Facilities", "ventilation_secondary_space_type": "Small-animal-cage room (ventilated cages)", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 3, @@ -145,10 +145,10 @@ { "ventilation_primary_space_type": "Correctional Facilities", "ventilation_secondary_space_type": "Booking/waiting", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 50, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -158,10 +158,10 @@ { "ventilation_primary_space_type": "Correctional Facilities", "ventilation_secondary_space_type": "Cell", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 25, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -171,10 +171,10 @@ { "ventilation_primary_space_type": "Correctional Facilities", "ventilation_secondary_space_type": "Dayroom", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 30, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -184,10 +184,10 @@ { "ventilation_primary_space_type": "Correctional Facilities", "ventilation_secondary_space_type": "Guard stations", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 15, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -197,10 +197,10 @@ { "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Art classroom", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -210,10 +210,10 @@ { "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Classrooms (ages 5 to 8)", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 25, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -223,10 +223,10 @@ { "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Classrooms (age 9 plus)", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 35, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -236,10 +236,10 @@ { "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Computer lab", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 25, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -249,10 +249,10 @@ { "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Daycare sickroom", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 25, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 3, @@ -262,10 +262,10 @@ { "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Daycare (through age 4)", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 25, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -275,10 +275,10 @@ { "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Lecture classroom", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 65, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -288,10 +288,10 @@ { "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Lecture hall (fixed seats)", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 150, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -301,10 +301,10 @@ { "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Libraries (education)", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 10, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": null, @@ -314,10 +314,10 @@ { "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Media center", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 25, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -327,10 +327,10 @@ { "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Multiuse assembly", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 100, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -340,10 +340,10 @@ { "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Music/theater/dance", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 35, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -353,10 +353,10 @@ { "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Science laboratories", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 25, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -366,10 +366,10 @@ { "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "University/college laboratories", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 25, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -379,10 +379,10 @@ { "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Wood/metal shop", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -392,10 +392,10 @@ { "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Bars, cocktail lounges", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 100, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -405,10 +405,10 @@ { "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast-food dining", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 100, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -418,10 +418,10 @@ { "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Kitchen (cooking)", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -431,10 +431,10 @@ { "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Restaurant dining rooms", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 70, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -444,10 +444,10 @@ { "ventilation_primary_space_type": "Food and Beverage Service, General", "ventilation_secondary_space_type": "Break rooms", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 25, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -457,10 +457,10 @@ { "ventilation_primary_space_type": "Food and Beverage Service, General", "ventilation_secondary_space_type": "Coffee stations", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -470,10 +470,10 @@ { "ventilation_primary_space_type": "Food and Beverage Service, General", "ventilation_secondary_space_type": "Conference/meeting", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 50, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -483,11 +483,11 @@ { "ventilation_primary_space_type": "Food and Beverage Service, General", "ventilation_secondary_space_type": "Corridors", - "ventilation_per_person": null, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", - "occupancy_per_area": null, + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, "os": "yes", @@ -496,10 +496,10 @@ { "ventilation_primary_space_type": "Food and Beverage Service, General", "ventilation_secondary_space_type": "Occupiable storage rooms for liquids or gels", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 2, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -509,10 +509,10 @@ { "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Barracks sleeping areas", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -522,10 +522,10 @@ { "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living room", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 10, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -535,10 +535,10 @@ { "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Laundry rooms, central", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 10, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -548,10 +548,10 @@ { "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Laundry rooms within dwelling units", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 10, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -561,10 +561,10 @@ { "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies/prefunction", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 30, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -574,10 +574,10 @@ { "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Multipurpose assembly", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 120, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -587,10 +587,10 @@ { "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Banks or bank lobbies", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 15, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -600,10 +600,10 @@ { "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Bank vaults/safe deposit", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 5, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -613,10 +613,10 @@ { "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Computer (not printing)", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 4, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -625,11 +625,11 @@ }, { "ventilation_primary_space_type": "Miscellaneous Spaces", - "ventilation_secondary_space_type": "Freezer and refrigerated spaces (<50\u00ef\u00bf\u00bdF [10\u00ef\u00bf\u00bdC])", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_secondary_space_type": "Freezer and refrigerated spaces (<50\u00c3\u00af\u00c2\u00bf\u00c2\u00bdF [10\u00c3\u00af\u00c2\u00bf\u00c2\u00bdC])", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 0, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -639,10 +639,10 @@ { "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Manufacturing where hazardous materials are not used", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 7, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -652,10 +652,10 @@ { "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Manufacturing where hazardous materials are used (excludes heavy industrial and chemical processes)", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 7, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 3, @@ -665,10 +665,10 @@ { "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Pharmacy (prep. area)", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 10, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -678,10 +678,10 @@ { "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Photo studios", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 10, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -691,10 +691,10 @@ { "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Shipping/receiving", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 2, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -704,10 +704,10 @@ { "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Sorting, packing, light assembly", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 7, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -717,11 +717,11 @@ { "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Telephone closets", - "ventilation_per_person": null, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0, - "ventilation_per_area_unit": "cfm/ft2", - "occupancy_per_area": null, + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, "os": null, @@ -730,10 +730,10 @@ { "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Transportation waiting", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 100, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -743,11 +743,11 @@ { "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Warehouses", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", - "occupancy_per_area": null, + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, "os": null, @@ -756,10 +756,10 @@ { "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Breakrooms", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 50, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -769,10 +769,10 @@ { "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Main entry lobbies", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 10, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -782,10 +782,10 @@ { "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Occupiable storage rooms for dry materials", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 2, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -795,10 +795,10 @@ { "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 5, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -808,10 +808,10 @@ { "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Reception areas", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 30, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -821,10 +821,10 @@ { "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Telephone/data entry", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 60, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -834,10 +834,10 @@ { "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Birthing room", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 15, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -847,10 +847,10 @@ { "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Class 1 imaging rooms", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 5, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -860,10 +860,10 @@ { "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Dental operatory", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -873,10 +873,10 @@ { "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "General examination room", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -886,10 +886,10 @@ { "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Other dental treatment areas", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 5, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -899,10 +899,10 @@ { "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Physical therapy exercise area", - "ventilation_per_person": 20, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 7, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -912,10 +912,10 @@ { "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Physical therapy individual room", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -925,11 +925,11 @@ { "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Physical therapeutic pool area", - "ventilation_per_person": null, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.48, - "ventilation_per_area_unit": "cfm/ft2", - "occupancy_per_area": null, + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.48, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, "os": null, @@ -938,10 +938,10 @@ { "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Prosthetics and orthotics room", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -951,10 +951,10 @@ { "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Psychiatric consultation room", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -964,10 +964,10 @@ { "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Psychiatric examination room", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -977,10 +977,10 @@ { "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Psychiatric group room", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 50, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -990,10 +990,10 @@ { "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Psychiatric seclusion room", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 5, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -1003,10 +1003,10 @@ { "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Speech therapy room", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -1016,10 +1016,10 @@ { "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Urgent care examination room", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -1029,10 +1029,10 @@ { "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Urgent care observation room", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -1042,10 +1042,10 @@ { "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Urgent care treatment room", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -1055,10 +1055,10 @@ { "ventilation_primary_space_type": "Outpatient Health Care Facilities", "ventilation_secondary_space_type": "Urgent care triage room", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -1068,10 +1068,10 @@ { "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Auditorium seating area", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 150, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -1081,10 +1081,10 @@ { "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Courtrooms", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 70, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -1094,10 +1094,10 @@ { "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Legislative chambers", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 50, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -1107,10 +1107,10 @@ { "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Libraries (public assembly)", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 10, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -1120,10 +1120,10 @@ { "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Lobbies", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 150, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -1133,10 +1133,10 @@ { "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Museums (children's)", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 40, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -1146,10 +1146,10 @@ { "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Museums/galleries", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 40, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -1159,10 +1159,10 @@ { "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Places of religious worship", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 120, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -1172,10 +1172,10 @@ { "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Sales (except as below)", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 15, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -1185,10 +1185,10 @@ { "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Barbershop", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 25, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -1198,10 +1198,10 @@ { "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Beauty and nail salons", - "ventilation_per_person": 20, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 25, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -1211,10 +1211,10 @@ { "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Coin-operated laundries", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -1224,10 +1224,10 @@ { "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Mall common areas", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 40, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -1237,10 +1237,10 @@ { "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Pet shops (animal areas)", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 10, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -1250,10 +1250,10 @@ { "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Supermarket", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 8, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -1263,10 +1263,10 @@ { "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Bowling alley (seating)", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.12, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.12, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 40, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -1276,10 +1276,10 @@ { "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Disco/dance floors", - "ventilation_per_person": 20, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 100, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -1289,10 +1289,10 @@ { "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Gambling casinos", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 120, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -1302,10 +1302,10 @@ { "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Game arcades", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 20, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -1315,10 +1315,10 @@ { "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Gym, sports arena (play area)", - "ventilation_per_person": 20, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.18, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.18, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 7, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -1328,10 +1328,10 @@ { "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Health club/aerobics room", - "ventilation_per_person": 20, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 40, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -1341,10 +1341,10 @@ { "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Health club/weight rooms", - "ventilation_per_person": 20, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 20, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 10, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, @@ -1354,10 +1354,10 @@ { "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Spectator areas", - "ventilation_per_person": 7.5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 7.5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 150, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -1367,10 +1367,10 @@ { "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Stages, studios", - "ventilation_per_person": 10, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 10, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 70, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, @@ -1380,11 +1380,11 @@ { "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Swimming (pool and deck)", - "ventilation_per_person": null, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.48, - "ventilation_per_area_unit": "cfm/ft2", - "occupancy_per_area": null, + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.48, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 2, "os": null, @@ -1393,11 +1393,11 @@ { "ventilation_primary_space_type": "Transient Residential", "ventilation_secondary_space_type": "Common corridors", - "ventilation_per_person": null, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", - "occupancy_per_area": null, + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, "os": "yes", @@ -1406,14 +1406,27 @@ { "ventilation_primary_space_type": "Transient Residential", "ventilation_secondary_space_type": "Dwelling unit", - "ventilation_per_person": 5, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.06, - "ventilation_per_area_unit": "cfm/ft2", - "occupancy_per_area": null, + "ventilation_rate_occupant": 5, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.06, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 1, "os": "yes", "annotation": "" + }, + { + "ventilation_primary_space_type": "None", + "ventilation_secondary_space_type": "None", + "ventilation_rate_occupant": 0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0, + "ventilation_rate_area_unit": "cfm/ft2", + "occupancy_per_area": 0, + "occupancy_per_area_unit": "ppl/1000 ft2", + "air_class": null, + "os": null, + "annotation": "" } ] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.csv b/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.csv index 6cc1ce0e8f..dee70d0342 100644 --- a/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.csv +++ b/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.csv @@ -1,155 +1,54 @@ support_electric_equipment_space_type_name_tags -corridor - all other -dining - all other -electrical/mechanical -kitchen -laboratory -lobby - all other -locker room -lounge/breakroom - all other -office - enclosed <= 250 sf -office - enclosed > 250 sf -office - open -restroom - all other -stairwell -storage < 50 sf - all other -storage 50 to 1000 sf - all other -vehicular maintenance -atrium - first three floors -audience seating - convention center -classroom/lecture/training - all other -conference/meeting/multipurpose -exhibit - convention center -gymnasium exercise area -gymnasium playing area -laundry/washing -lobby - elevator -nurses station -post office - sorting area -"sports arena playing area, class IV" -audience seating - all other -confinement cells -judges chambers -library - stacks -storage - inactive -dining - bar/lounge/leisure -dining - cafeteria/fast food -dining - family -computer room -dormitory - living quarters -audience seating - exercise center -exam/treatment -library - reading -emergency vehicle garage -firestation - sleeping quarters -"parking area, interior" -audience seating - gymnasium -emergency room -patient room -corridor - hospital -fellowship hall - religious facility -lounge/breakroom - healthcare facility -operating room -physical therapy -storage < 50 sf - hospital -storage 50 to 1000 sf - hospital -guest room -lobby - hotel -library - cataloging -museum exhibit area -corridor - manufacturing facility -manufacturing equipment room -manufacturing low bay -performing arts dressing room -audience seating - auditorium -audience seating - motion picture theater -lobby - motion picture theater -Dwelling Unit -museum restoration -banking activity -warehouse - fine storage -classroom/lecture/training - penitentiary -dining - penitentiary -audience seating - performing arts theater -lobby - performing arts theater -audience seating - religious facility -worship/pulpit/choir area -classroom/lecture/training - preschool to 12th -"sports arena playing area, class II" -audience seating - sports arena -airport concourse -atrium < 20 ft height -atrium > 40 ft height -atrium >= 20 ft and <= 40 ft in height -baggage/carousel -"seating area, general" -transportation ticket counter -warehouse - bulk storage -workshop -gymnasium_playing_area -gymnasium_exercise_area -courtroom -confinement_cells -judges_chambers -emergency_vehicle_garage -firestation_sleeping_quarters -post_office_sorting_area -exhibit_convention_center -library_cataloging -library_stacks -library_reading -emergency_room -recovery -nurses_station -exam_treatment -pharmacy -patient_room -operating_room -nursery -medical_supply -physical_therapy -imaging -laundry_washing -automotive -manufacturing_low_bay -manufacturing_high_bay -detailed_manufacuring -manufacturing_equipment_room -manufacturing_control -manufacturing_extra_high_bay -guest_room -dormitory_living_quarters -museum_exhibit_area -museum_restoration -banking_activity -worship_pulpit_choir_area -fellowship_hall_religious_facility -sales -retail_mall_concourse -retail_dressing_room -sports_arena_ring_sports_area -sports_arena_court_sports_area -sports_arena_indoor_playing_field -sports_arena_playing_area_class_I -sports_arena_playing_area_class_II -sports_arena_playing_area_class_III -sports_arena_playing_area_class_IV -warehouse_fine_storage -warehouse_bulk_storage -parking_area_interior -airport_concourse -baggage_carousel -transportation_ticket_counter -sales_display_type_1 -sales_display_type_2 -sales_display_type_3 -sales_display_type_4 -breakroom -copy_print -computer_room -loading_dock -locker_room -seating_area_general -vehicular_maintenance -chapel_visually_impaired -recreation_common_living_visually_impaired +airport_concourse_electric_equipment +atrium_lt_20_ft_height_electric_equipment +attic_electric_equipment +audience_seating_all_other_electric_equipment +baggage_carousel_electric_equipment +banking_activity_electric_equipment +classroom_lecture_training_all_other_electric_equipment +computer_room_electric_equipment +conference_meeting_multipurpose_electric_equipment +confinement_cells_electric_equipment +corridor_all_other_electric_equipment +courtroom_electric_equipment +dining_all_other_electric_equipment +performing_arts_dressing_room_electric_equipment +electrical_mechanical_electric_equipment +emergency_room_electric_equipment +emergency_vehicle_garage_electric_equipment +exam_treatment_electric_equipment +gymnasium_exercise_area_electric_equipment +museum_exhibit_area_electric_equipment +guest_room_electric_equipment +parking_area_interior_electric_equipment +judges_chambers_electric_equipment +kitchen_electric_equipment +laboratory_electric_equipment +laundry_washing_electric_equipment +library_stacks_electric_equipment +dormitory_living_quarters_electric_equipment +lobby_all_other_electric_equipment +locker_room_electric_equipment +lounge_breakroom_all_other_electric_equipment +manufacturing_low_bay_electric_equipment +pharmacy_electric_equipment +patient_room_electric_equipment +nurses_station_electric_equipment +office_open_electric_equipment +office_enclosed_lte_250_sf_electric_equipment +operating_room_electric_equipment +physical_therapy_electric_equipment +gymnasium_playing_area_electric_equipment +plenum_electric_equipment +post_office_sorting_area_electric_equipment +restroom_all_other_electric_equipment +sales_electric_equipment +shaft_electric_equipment +firestation_sleeping_quarters_electric_equipment +sports_arena_playing_area_class_ii_electric_equipment +stairwell_electric_equipment +storage_50_to_1000_sf_all_other_electric_equipment +transportation_ticket_counter_electric_equipment +vehicular_maintenance_electric_equipment +workshop_electric_equipment +worship_pulpit_choir_area_electric_equipment diff --git a/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.json b/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.json index 19c940c013..065ee40161 100644 --- a/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.json +++ b/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.json @@ -1,464 +1,161 @@ [ { - "support_electric_equipment_space_type_name_tags": "corridor - all other" + "support_electric_equipment_space_type_name_tags": "airport_concourse_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "dining - all other" + "support_electric_equipment_space_type_name_tags": "atrium_lt_20_ft_height_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "electrical/mechanical" + "support_electric_equipment_space_type_name_tags": "attic_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "kitchen" + "support_electric_equipment_space_type_name_tags": "audience_seating_all_other_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "laboratory" + "support_electric_equipment_space_type_name_tags": "baggage_carousel_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "lobby - all other" + "support_electric_equipment_space_type_name_tags": "banking_activity_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "locker room" + "support_electric_equipment_space_type_name_tags": "classroom_lecture_training_all_other_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "lounge/breakroom - all other" + "support_electric_equipment_space_type_name_tags": "computer_room_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "office - enclosed <= 250 sf" + "support_electric_equipment_space_type_name_tags": "conference_meeting_multipurpose_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "office - enclosed > 250 sf" + "support_electric_equipment_space_type_name_tags": "confinement_cells_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "office - open" + "support_electric_equipment_space_type_name_tags": "corridor_all_other_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "restroom - all other" + "support_electric_equipment_space_type_name_tags": "courtroom_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "stairwell" + "support_electric_equipment_space_type_name_tags": "dining_all_other_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "storage < 50 sf - all other" + "support_electric_equipment_space_type_name_tags": "performing_arts_dressing_room_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "storage 50 to 1000 sf - all other" + "support_electric_equipment_space_type_name_tags": "electrical_mechanical_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "vehicular maintenance" + "support_electric_equipment_space_type_name_tags": "emergency_room_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "atrium - first three floors" + "support_electric_equipment_space_type_name_tags": "emergency_vehicle_garage_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "audience seating - convention center" + "support_electric_equipment_space_type_name_tags": "exam_treatment_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "classroom/lecture/training - all other" + "support_electric_equipment_space_type_name_tags": "gymnasium_exercise_area_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "conference/meeting/multipurpose" + "support_electric_equipment_space_type_name_tags": "museum_exhibit_area_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "exhibit - convention center" + "support_electric_equipment_space_type_name_tags": "guest_room_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "gymnasium exercise area" + "support_electric_equipment_space_type_name_tags": "parking_area_interior_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "gymnasium playing area" + "support_electric_equipment_space_type_name_tags": "judges_chambers_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "laundry/washing" + "support_electric_equipment_space_type_name_tags": "kitchen_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "lobby - elevator" + "support_electric_equipment_space_type_name_tags": "laboratory_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "nurses station" + "support_electric_equipment_space_type_name_tags": "laundry_washing_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "post office - sorting area" + "support_electric_equipment_space_type_name_tags": "library_stacks_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "sports arena playing area, class IV" + "support_electric_equipment_space_type_name_tags": "dormitory_living_quarters_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "audience seating - all other" + "support_electric_equipment_space_type_name_tags": "lobby_all_other_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "confinement cells" + "support_electric_equipment_space_type_name_tags": "locker_room_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "judges chambers" + "support_electric_equipment_space_type_name_tags": "lounge_breakroom_all_other_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "library - stacks" + "support_electric_equipment_space_type_name_tags": "manufacturing_low_bay_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "storage - inactive" + "support_electric_equipment_space_type_name_tags": "pharmacy_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "dining - bar/lounge/leisure" + "support_electric_equipment_space_type_name_tags": "patient_room_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "dining - cafeteria/fast food" + "support_electric_equipment_space_type_name_tags": "nurses_station_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "dining - family" + "support_electric_equipment_space_type_name_tags": "office_open_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "computer room" + "support_electric_equipment_space_type_name_tags": "office_enclosed_lte_250_sf_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "dormitory - living quarters" + "support_electric_equipment_space_type_name_tags": "operating_room_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "audience seating - exercise center" + "support_electric_equipment_space_type_name_tags": "physical_therapy_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "exam/treatment" + "support_electric_equipment_space_type_name_tags": "gymnasium_playing_area_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "library - reading" + "support_electric_equipment_space_type_name_tags": "plenum_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "emergency vehicle garage" + "support_electric_equipment_space_type_name_tags": "post_office_sorting_area_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "firestation - sleeping quarters" + "support_electric_equipment_space_type_name_tags": "restroom_all_other_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "parking area, interior" + "support_electric_equipment_space_type_name_tags": "sales_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "audience seating - gymnasium" + "support_electric_equipment_space_type_name_tags": "shaft_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "emergency room" + "support_electric_equipment_space_type_name_tags": "firestation_sleeping_quarters_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "patient room" + "support_electric_equipment_space_type_name_tags": "sports_arena_playing_area_class_ii_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "corridor - hospital" + "support_electric_equipment_space_type_name_tags": "stairwell_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "fellowship hall - religious facility" + "support_electric_equipment_space_type_name_tags": "storage_50_to_1000_sf_all_other_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "lounge/breakroom - healthcare facility" + "support_electric_equipment_space_type_name_tags": "transportation_ticket_counter_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "operating room" + "support_electric_equipment_space_type_name_tags": "vehicular_maintenance_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "physical therapy" + "support_electric_equipment_space_type_name_tags": "workshop_electric_equipment" }, { - "support_electric_equipment_space_type_name_tags": "storage < 50 sf - hospital" - }, - { - "support_electric_equipment_space_type_name_tags": "storage 50 to 1000 sf - hospital" - }, - { - "support_electric_equipment_space_type_name_tags": "guest room" - }, - { - "support_electric_equipment_space_type_name_tags": "lobby - hotel" - }, - { - "support_electric_equipment_space_type_name_tags": "library - cataloging" - }, - { - "support_electric_equipment_space_type_name_tags": "museum exhibit area" - }, - { - "support_electric_equipment_space_type_name_tags": "corridor - manufacturing facility" - }, - { - "support_electric_equipment_space_type_name_tags": "manufacturing equipment room" - }, - { - "support_electric_equipment_space_type_name_tags": "manufacturing low bay" - }, - { - "support_electric_equipment_space_type_name_tags": "performing arts dressing room" - }, - { - "support_electric_equipment_space_type_name_tags": "audience seating - auditorium" - }, - { - "support_electric_equipment_space_type_name_tags": "audience seating - motion picture theater" - }, - { - "support_electric_equipment_space_type_name_tags": "lobby - motion picture theater" - }, - { - "support_electric_equipment_space_type_name_tags": "Dwelling Unit" - }, - { - "support_electric_equipment_space_type_name_tags": "museum restoration" - }, - { - "support_electric_equipment_space_type_name_tags": "banking activity" - }, - { - "support_electric_equipment_space_type_name_tags": "warehouse - fine storage" - }, - { - "support_electric_equipment_space_type_name_tags": "classroom/lecture/training - penitentiary" - }, - { - "support_electric_equipment_space_type_name_tags": "dining - penitentiary" - }, - { - "support_electric_equipment_space_type_name_tags": "audience seating - performing arts theater" - }, - { - "support_electric_equipment_space_type_name_tags": "lobby - performing arts theater" - }, - { - "support_electric_equipment_space_type_name_tags": "audience seating - religious facility" - }, - { - "support_electric_equipment_space_type_name_tags": "worship/pulpit/choir area" - }, - { - "support_electric_equipment_space_type_name_tags": "classroom/lecture/training - preschool to 12th" - }, - { - "support_electric_equipment_space_type_name_tags": "sports arena playing area, class II" - }, - { - "support_electric_equipment_space_type_name_tags": "audience seating - sports arena" - }, - { - "support_electric_equipment_space_type_name_tags": "airport concourse" - }, - { - "support_electric_equipment_space_type_name_tags": "atrium < 20 ft height" - }, - { - "support_electric_equipment_space_type_name_tags": "atrium > 40 ft height" - }, - { - "support_electric_equipment_space_type_name_tags": "atrium >= 20 ft and <= 40 ft in height" - }, - { - "support_electric_equipment_space_type_name_tags": "baggage/carousel" - }, - { - "support_electric_equipment_space_type_name_tags": "seating area, general" - }, - { - "support_electric_equipment_space_type_name_tags": "transportation ticket counter" - }, - { - "support_electric_equipment_space_type_name_tags": "warehouse - bulk storage" - }, - { - "support_electric_equipment_space_type_name_tags": "workshop" - }, - { - "support_electric_equipment_space_type_name_tags": "gymnasium_playing_area" - }, - { - "support_electric_equipment_space_type_name_tags": "gymnasium_exercise_area" - }, - { - "support_electric_equipment_space_type_name_tags": "courtroom" - }, - { - "support_electric_equipment_space_type_name_tags": "confinement_cells" - }, - { - "support_electric_equipment_space_type_name_tags": "judges_chambers" - }, - { - "support_electric_equipment_space_type_name_tags": "emergency_vehicle_garage" - }, - { - "support_electric_equipment_space_type_name_tags": "firestation_sleeping_quarters" - }, - { - "support_electric_equipment_space_type_name_tags": "post_office_sorting_area" - }, - { - "support_electric_equipment_space_type_name_tags": "exhibit_convention_center" - }, - { - "support_electric_equipment_space_type_name_tags": "library_cataloging" - }, - { - "support_electric_equipment_space_type_name_tags": "library_stacks" - }, - { - "support_electric_equipment_space_type_name_tags": "library_reading" - }, - { - "support_electric_equipment_space_type_name_tags": "emergency_room" - }, - { - "support_electric_equipment_space_type_name_tags": "recovery" - }, - { - "support_electric_equipment_space_type_name_tags": "nurses_station" - }, - { - "support_electric_equipment_space_type_name_tags": "exam_treatment" - }, - { - "support_electric_equipment_space_type_name_tags": "pharmacy" - }, - { - "support_electric_equipment_space_type_name_tags": "patient_room" - }, - { - "support_electric_equipment_space_type_name_tags": "operating_room" - }, - { - "support_electric_equipment_space_type_name_tags": "nursery" - }, - { - "support_electric_equipment_space_type_name_tags": "medical_supply" - }, - { - "support_electric_equipment_space_type_name_tags": "physical_therapy" - }, - { - "support_electric_equipment_space_type_name_tags": "imaging" - }, - { - "support_electric_equipment_space_type_name_tags": "laundry_washing" - }, - { - "support_electric_equipment_space_type_name_tags": "automotive" - }, - { - "support_electric_equipment_space_type_name_tags": "manufacturing_low_bay" - }, - { - "support_electric_equipment_space_type_name_tags": "manufacturing_high_bay" - }, - { - "support_electric_equipment_space_type_name_tags": "detailed_manufacuring" - }, - { - "support_electric_equipment_space_type_name_tags": "manufacturing_equipment_room" - }, - { - "support_electric_equipment_space_type_name_tags": "manufacturing_control" - }, - { - "support_electric_equipment_space_type_name_tags": "manufacturing_extra_high_bay" - }, - { - "support_electric_equipment_space_type_name_tags": "guest_room" - }, - { - "support_electric_equipment_space_type_name_tags": "dormitory_living_quarters" - }, - { - "support_electric_equipment_space_type_name_tags": "museum_exhibit_area" - }, - { - "support_electric_equipment_space_type_name_tags": "museum_restoration" - }, - { - "support_electric_equipment_space_type_name_tags": "banking_activity" - }, - { - "support_electric_equipment_space_type_name_tags": "worship_pulpit_choir_area" - }, - { - "support_electric_equipment_space_type_name_tags": "fellowship_hall_religious_facility" - }, - { - "support_electric_equipment_space_type_name_tags": "sales" - }, - { - "support_electric_equipment_space_type_name_tags": "retail_mall_concourse" - }, - { - "support_electric_equipment_space_type_name_tags": "retail_dressing_room" - }, - { - "support_electric_equipment_space_type_name_tags": "sports_arena_ring_sports_area" - }, - { - "support_electric_equipment_space_type_name_tags": "sports_arena_court_sports_area" - }, - { - "support_electric_equipment_space_type_name_tags": "sports_arena_indoor_playing_field" - }, - { - "support_electric_equipment_space_type_name_tags": "sports_arena_playing_area_class_I" - }, - { - "support_electric_equipment_space_type_name_tags": "sports_arena_playing_area_class_II" - }, - { - "support_electric_equipment_space_type_name_tags": "sports_arena_playing_area_class_III" - }, - { - "support_electric_equipment_space_type_name_tags": "sports_arena_playing_area_class_IV" - }, - { - "support_electric_equipment_space_type_name_tags": "warehouse_fine_storage" - }, - { - "support_electric_equipment_space_type_name_tags": "warehouse_bulk_storage" - }, - { - "support_electric_equipment_space_type_name_tags": "parking_area_interior" - }, - { - "support_electric_equipment_space_type_name_tags": "airport_concourse" - }, - { - "support_electric_equipment_space_type_name_tags": "baggage_carousel" - }, - { - "support_electric_equipment_space_type_name_tags": "transportation_ticket_counter" - }, - { - "support_electric_equipment_space_type_name_tags": "sales_display_type_1" - }, - { - "support_electric_equipment_space_type_name_tags": "sales_display_type_2" - }, - { - "support_electric_equipment_space_type_name_tags": "sales_display_type_3" - }, - { - "support_electric_equipment_space_type_name_tags": "sales_display_type_4" - }, - { - "support_electric_equipment_space_type_name_tags": "breakroom" - }, - { - "support_electric_equipment_space_type_name_tags": "copy_print" - }, - { - "support_electric_equipment_space_type_name_tags": "computer_room" - }, - { - "support_electric_equipment_space_type_name_tags": "loading_dock" - }, - { - "support_electric_equipment_space_type_name_tags": "locker_room" - }, - { - "support_electric_equipment_space_type_name_tags": "seating_area_general" - }, - { - "support_electric_equipment_space_type_name_tags": "vehicular_maintenance" - }, - { - "support_electric_equipment_space_type_name_tags": "chapel_visually_impaired" - }, - { - "support_electric_equipment_space_type_name_tags": "recreation_common_living_visually_impaired" + "support_electric_equipment_space_type_name_tags": "worship_pulpit_choir_area_electric_equipment" } ] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/support_lighting_space_type_name_tags.csv b/data/openstudio_standards_data/database_files/support_lighting_space_type_name_tags.csv index aa285798d8..b7d064fb58 100644 --- a/data/openstudio_standards_data/database_files/support_lighting_space_type_name_tags.csv +++ b/data/openstudio_standards_data/database_files/support_lighting_space_type_name_tags.csv @@ -1,159 +1,119 @@ lighting_space_type_name -bam_automotive_facility -bam_convention_center -bam_courthouse -bam_dinin_bar_lounge_leisure -bam_dining_cafeteria_fast_food -bam_dining_family -bam_dormitory -bam_exercise_center -bam_fire_station -bam_gymnasium -bam_healthcare_clinic -bam_hospital -bam_hotel -bam_library -bam_manufacturing_facility -bam_motel -bam_motion_picture_theater -bam_multifamily -bam_museum -bam_office -bam_parking_garage -bam_penitentiary -bam_performing_arts_theater -bam_police_station -bam_post_office -bam_religious_facility -bam_retail -bam_school_university -bam_sports_arena -bam_town_hall -bam_transportation -bam_warehouse -bam_workshop -office_enclosed_small -office_enclosed_large -office_open -conference_meeting_multipurpose -classroom_lecture_training_general -classroom_lecture_training_penitentiary -lobby_general -lobby_hotel -lobby_performing_arts_theater -lobby_motion_picture_theater -lobby_visually_impaired -lobby_elevator -audience_seating_general -audience_seating_gymnasium -audience_seating_exercise_center -audience_seating_convention_center -audience_seating_penitentiary -audience_seating_religious_facility -audience_seating_sports_arena -audience_seating_performing_arts_theater -audience_seating_motion_picture_theater -audience_seating_transportation -audience_seating_auditorium -atrium_first_three_floor -atrium_each_additional_floor -atrium_low -atrium_medium -atrium_high -lounge_breakroom_general -lounge_breakroom_healthcare_facility -dining_general -dining_penitentiary -dining_hotel -dining_motel -dining_bar_lounge_leisure -dining_family -dining_cafeteria_fast_food -dining_visually_impaired -kitchen -laboratory_classroom -laboratory_all_other -restroom_visually_impaired -restroom_all_other -performing_arts_dressing_room -corridor_general -corridor_hospital -corridor_manufacturing_facility -corridor_visually_impaired -stairway -stairwell -storage_ all_other_small -storage_ all_other_large -storage_hospital_small -storage_hospital_large -storage_inactive -storage_inactive_museum -electrical_mechanical -workshop -gymnasium_playing_area -gymnasium_exercise_area -courtroom -confinement_cells -judges_chambers -emergency_vehicle_garage -firestation_sleeping_quarters -post_office_sorting_area -exhibit_convention_center -library_cataloging -library_stacks -library_reading -emergency_room -recovery -nurses_station -exam_treatment -pharmacy -patient_room -operating_room -nursery -medical_supply -physical_therapy -imaging -laundry_washing -automotive -manufacturing_low_bay -manufacturing_high_bay -detailed_manufacuring -manufacturing_equipment_room -manufacturing_control -manufacturing_extra_high_bay -guest_room -dormitory_living_quarters -museum_exhibit_area -museum_restoration -banking_activity -worship_pulpit_choir_area -fellowship_hall_religious_facility -sales -retail_mall_concourse -retail_dressing_room -sports_arena_ring_sports_area -sports_arena_court_sports_area -sports_arena_indoor_playing_field -sports_arena_playing_area_class_I -sports_arena_playing_area_class_II -sports_arena_playing_area_class_III -sports_arena_playing_area_class_IV -warehouse_fine_storage -warehouse_bulk_storage -parking_area_interior -airport_concourse -baggage_carousel -transportation_ticket_counter -sales_display_type_1 -sales_display_type_2 -sales_display_type_3 -sales_display_type_4 -breakroom -copy_print -computer_room -loading_dock -locker_room -seating_area_general -vehicular_maintenance -chapel_visually_impaired -recreation_common_living_visually_impaired +airport_concourse_lighting +atrium_lighting +none_lighting +audience_seating_lighting +baggage_carousel_lighting +banking_lighting +classroom_lecture_training_lighting +computer_room_lighting +conference_meeting_multipurpose_lighting +confinement_cells_lighting +copy_print_lighting +corridor_lighting +courtroom_lighting +datacenterhighite_lighting +datacenterlowite_lighting +dining_lighting +dressing_room_lighting +electrical_mechanical_lighting +emergency_room_lighting +emergency_vehicle_garage_lighting +exam_treatment_lighting +exercise_area_lighting +exhibit_lighting +guest_room_lighting +imaging_lighting +interior_parking_lighting +judges_chambers_lighting +food_preparation_lighting +laboratory_lighting +laundry_washing_lighting +library_lighting +living_quarters_lighting +loading_dock_lighting +lobby_lighting +locker_room_lighting +lounge_breakroom_lighting +manufacturing_lighting +medical_supply_lighting +multifamily_lighting +nursery_lighting +nurses_station_lighting +office_lighting +office_enclosed_lighting +operating_room_lighting +patient_room_lighting +pharmacy_lighting +physical_therapy_lighting +playing_area_lighting +post_office_lighting +recovery_lighting +recreation_common_living_lighting +restroom_lighting +retail_sales_lighting +sleeping_quarters_lighting +sports_arena_lighting +stairwell_lighting +storage_lighting +transportation_lighting +vehicular_maintenance_lighting +workshop_lighting +worship_lighting +ba_automotive_facility_lighting +ba_convention_center_lighting +ba_courthouse_lighting +ba_dining_bar_lounge_leisure_lighting +ba_dining_cafeteria_fast_food_lighting +ba_dining_family_lighting +ba_dormitory_lighting +ba_exercise_center_lighting +ba_fire_station_lighting +ba_gymnasium_lighting +ba_health-care_clinic_lighting +ba_hospital_lighting +ba_hotel_motel_lighting +ba_motion_picture_theater_lighting +ba_museum_lighting +ba_parking_garage_lighting +ba_penitentiary_lighting +ba_performing_arts_theater_lighting +ba_police_station_lighting +ba_school_university_lighting +ba_town_hall_lighting +ba_retail_lighting +ba_warehouse_lighting +audience_seating_area_for_gymnasium_lighting +audience_seating_area_for_motion_picture_theater_lighting +audience_seating_area_for_penitentiary_lighting +audience_seating_area_for_performing_arts_theater_lighting +audience_seating_area_for_religious_buildings_lighting +audience_seating_area_for_sports_arena_lighting +classroom_lecture_training_for_penitentiary_lighting +corridor_transition_for_hospital_lighting +dining_area_for_penitentiary_lighting +dining_bar_lounge_leisure_general_lighting +dining_cafeteria_fast_food_general_lighting +dining_area_for_family_dining_lighting +lobby_for_hotel_lighting +lobby_for_motion_picture_theater_lighting +lobby_for_performing_arts_theater_lighting +lounge_recreation_for_hospital_lighting +office-enclosed_general_lighting +office_open_plan_lighting +automotive_general_lighting +convention_center_exhibit_space_general_lighting +library_reading_area_lighting +library_stacks_lighting +manufacturing_facility_detailed_manufacturing_area_lighting +manufacturing_facility_equipment_room_lighting +manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting +manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting +museum_restoration_room_lighting +post_office_sorting_area_general_lighting +religious_buildings_fellowship_hall_lighting +religious_buildings_worship_pulpit_choir_lighting +retail_mall_concourse_lighting +transportation_facility_ticket_counter_lighting +warehouse_storage_area_medium_to_bulky_palletized_items_lighting +warehouse_storage_area_smaller_hand-carried_items_lighting diff --git a/data/openstudio_standards_data/database_files/support_lighting_space_type_name_tags.json b/data/openstudio_standards_data/database_files/support_lighting_space_type_name_tags.json index ec255589b7..78874e916f 100644 --- a/data/openstudio_standards_data/database_files/support_lighting_space_type_name_tags.json +++ b/data/openstudio_standards_data/database_files/support_lighting_space_type_name_tags.json @@ -1,476 +1,356 @@ [ { - "lighting_space_type_name": "bam_automotive_facility" + "lighting_space_type_name": "airport_concourse_lighting" }, { - "lighting_space_type_name": "bam_convention_center" + "lighting_space_type_name": "atrium_lighting" }, { - "lighting_space_type_name": "bam_courthouse" + "lighting_space_type_name": "none_lighting" }, { - "lighting_space_type_name": "bam_dinin_bar_lounge_leisure" + "lighting_space_type_name": "audience_seating_lighting" }, { - "lighting_space_type_name": "bam_dining_cafeteria_fast_food" + "lighting_space_type_name": "baggage_carousel_lighting" }, { - "lighting_space_type_name": "bam_dining_family" + "lighting_space_type_name": "banking_lighting" }, { - "lighting_space_type_name": "bam_dormitory" + "lighting_space_type_name": "classroom_lecture_training_lighting" }, { - "lighting_space_type_name": "bam_exercise_center" + "lighting_space_type_name": "computer_room_lighting" }, { - "lighting_space_type_name": "bam_fire_station" + "lighting_space_type_name": "conference_meeting_multipurpose_lighting" }, { - "lighting_space_type_name": "bam_gymnasium" + "lighting_space_type_name": "confinement_cells_lighting" }, { - "lighting_space_type_name": "bam_healthcare_clinic" + "lighting_space_type_name": "copy_print_lighting" }, { - "lighting_space_type_name": "bam_hospital" + "lighting_space_type_name": "corridor_lighting" }, { - "lighting_space_type_name": "bam_hotel" + "lighting_space_type_name": "courtroom_lighting" }, { - "lighting_space_type_name": "bam_library" + "lighting_space_type_name": "datacenterhighite_lighting" }, { - "lighting_space_type_name": "bam_manufacturing_facility" + "lighting_space_type_name": "datacenterlowite_lighting" }, { - "lighting_space_type_name": "bam_motel" + "lighting_space_type_name": "dining_lighting" }, { - "lighting_space_type_name": "bam_motion_picture_theater" + "lighting_space_type_name": "dressing_room_lighting" }, { - "lighting_space_type_name": "bam_multifamily" + "lighting_space_type_name": "electrical_mechanical_lighting" }, { - "lighting_space_type_name": "bam_museum" + "lighting_space_type_name": "emergency_room_lighting" }, { - "lighting_space_type_name": "bam_office" + "lighting_space_type_name": "emergency_vehicle_garage_lighting" }, { - "lighting_space_type_name": "bam_parking_garage" + "lighting_space_type_name": "exam_treatment_lighting" }, { - "lighting_space_type_name": "bam_penitentiary" + "lighting_space_type_name": "exercise_area_lighting" }, { - "lighting_space_type_name": "bam_performing_arts_theater" + "lighting_space_type_name": "exhibit_lighting" }, { - "lighting_space_type_name": "bam_police_station" + "lighting_space_type_name": "guest_room_lighting" }, { - "lighting_space_type_name": "bam_post_office" + "lighting_space_type_name": "imaging_lighting" }, { - "lighting_space_type_name": "bam_religious_facility" + "lighting_space_type_name": "interior_parking_lighting" }, { - "lighting_space_type_name": "bam_retail" + "lighting_space_type_name": "judges_chambers_lighting" }, { - "lighting_space_type_name": "bam_school_university" + "lighting_space_type_name": "food_preparation_lighting" }, { - "lighting_space_type_name": "bam_sports_arena" + "lighting_space_type_name": "laboratory_lighting" }, { - "lighting_space_type_name": "bam_town_hall" + "lighting_space_type_name": "laundry_washing_lighting" }, { - "lighting_space_type_name": "bam_transportation" + "lighting_space_type_name": "library_lighting" }, { - "lighting_space_type_name": "bam_warehouse" + "lighting_space_type_name": "living_quarters_lighting" }, { - "lighting_space_type_name": "bam_workshop" + "lighting_space_type_name": "loading_dock_lighting" }, { - "lighting_space_type_name": "office_enclosed_small" + "lighting_space_type_name": "lobby_lighting" }, { - "lighting_space_type_name": "office_enclosed_large" + "lighting_space_type_name": "locker_room_lighting" }, { - "lighting_space_type_name": "office_open" + "lighting_space_type_name": "lounge_breakroom_lighting" }, { - "lighting_space_type_name": "conference_meeting_multipurpose" + "lighting_space_type_name": "manufacturing_lighting" }, { - "lighting_space_type_name": "classroom_lecture_training_general" + "lighting_space_type_name": "medical_supply_lighting" }, { - "lighting_space_type_name": "classroom_lecture_training_penitentiary" + "lighting_space_type_name": "multifamily_lighting" }, { - "lighting_space_type_name": "lobby_general" + "lighting_space_type_name": "nursery_lighting" }, { - "lighting_space_type_name": "lobby_hotel" + "lighting_space_type_name": "nurses_station_lighting" }, { - "lighting_space_type_name": "lobby_performing_arts_theater" + "lighting_space_type_name": "office_lighting" }, { - "lighting_space_type_name": "lobby_motion_picture_theater" + "lighting_space_type_name": "office_enclosed_lighting" }, { - "lighting_space_type_name": "lobby_visually_impaired" + "lighting_space_type_name": "operating_room_lighting" }, { - "lighting_space_type_name": "lobby_elevator" + "lighting_space_type_name": "patient_room_lighting" }, { - "lighting_space_type_name": "audience_seating_general" + "lighting_space_type_name": "pharmacy_lighting" }, { - "lighting_space_type_name": "audience_seating_gymnasium" + "lighting_space_type_name": "physical_therapy_lighting" }, { - "lighting_space_type_name": "audience_seating_exercise_center" + "lighting_space_type_name": "playing_area_lighting" }, { - "lighting_space_type_name": "audience_seating_convention_center" + "lighting_space_type_name": "post_office_lighting" }, { - "lighting_space_type_name": "audience_seating_penitentiary" + "lighting_space_type_name": "recovery_lighting" }, { - "lighting_space_type_name": "audience_seating_religious_facility" + "lighting_space_type_name": "recreation_common_living_lighting" }, { - "lighting_space_type_name": "audience_seating_sports_arena" + "lighting_space_type_name": "restroom_lighting" }, { - "lighting_space_type_name": "audience_seating_performing_arts_theater" + "lighting_space_type_name": "retail_sales_lighting" }, { - "lighting_space_type_name": "audience_seating_motion_picture_theater" + "lighting_space_type_name": "sleeping_quarters_lighting" }, { - "lighting_space_type_name": "audience_seating_transportation" + "lighting_space_type_name": "sports_arena_lighting" }, { - "lighting_space_type_name": "audience_seating_auditorium" + "lighting_space_type_name": "stairwell_lighting" }, { - "lighting_space_type_name": "atrium_first_three_floor" + "lighting_space_type_name": "storage_lighting" }, { - "lighting_space_type_name": "atrium_each_additional_floor" + "lighting_space_type_name": "transportation_lighting" }, { - "lighting_space_type_name": "atrium_low" + "lighting_space_type_name": "vehicular_maintenance_lighting" }, { - "lighting_space_type_name": "atrium_medium" + "lighting_space_type_name": "workshop_lighting" }, { - "lighting_space_type_name": "atrium_high" + "lighting_space_type_name": "worship_lighting" }, { - "lighting_space_type_name": "lounge_breakroom_general" + "lighting_space_type_name": "ba_automotive_facility_lighting" }, { - "lighting_space_type_name": "lounge_breakroom_healthcare_facility" + "lighting_space_type_name": "ba_convention_center_lighting" }, { - "lighting_space_type_name": "dining_general" + "lighting_space_type_name": "ba_courthouse_lighting" }, { - "lighting_space_type_name": "dining_penitentiary" + "lighting_space_type_name": "ba_dining_bar_lounge_leisure_lighting" }, { - "lighting_space_type_name": "dining_hotel" + "lighting_space_type_name": "ba_dining_cafeteria_fast_food_lighting" }, { - "lighting_space_type_name": "dining_motel" + "lighting_space_type_name": "ba_dining_family_lighting" }, { - "lighting_space_type_name": "dining_bar_lounge_leisure" + "lighting_space_type_name": "ba_dormitory_lighting" }, { - "lighting_space_type_name": "dining_family" + "lighting_space_type_name": "ba_exercise_center_lighting" }, { - "lighting_space_type_name": "dining_cafeteria_fast_food" + "lighting_space_type_name": "ba_fire_station_lighting" }, { - "lighting_space_type_name": "dining_visually_impaired" + "lighting_space_type_name": "ba_gymnasium_lighting" }, { - "lighting_space_type_name": "kitchen" + "lighting_space_type_name": "ba_health-care_clinic_lighting" }, { - "lighting_space_type_name": "laboratory_classroom" + "lighting_space_type_name": "ba_hospital_lighting" }, { - "lighting_space_type_name": "laboratory_all_other" + "lighting_space_type_name": "ba_hotel_motel_lighting" }, { - "lighting_space_type_name": "restroom_visually_impaired" + "lighting_space_type_name": "ba_motion_picture_theater_lighting" }, { - "lighting_space_type_name": "restroom_all_other" + "lighting_space_type_name": "ba_museum_lighting" }, { - "lighting_space_type_name": "performing_arts_dressing_room" + "lighting_space_type_name": "ba_parking_garage_lighting" }, { - "lighting_space_type_name": "corridor_general" + "lighting_space_type_name": "ba_penitentiary_lighting" }, { - "lighting_space_type_name": "corridor_hospital" + "lighting_space_type_name": "ba_performing_arts_theater_lighting" }, { - "lighting_space_type_name": "corridor_manufacturing_facility" + "lighting_space_type_name": "ba_police_station_lighting" }, { - "lighting_space_type_name": "corridor_visually_impaired" + "lighting_space_type_name": "ba_school_university_lighting" }, { - "lighting_space_type_name": "stairway" + "lighting_space_type_name": "ba_town_hall_lighting" }, { - "lighting_space_type_name": "stairwell" + "lighting_space_type_name": "ba_retail_lighting" }, { - "lighting_space_type_name": "storage_ all_other_small" + "lighting_space_type_name": "ba_warehouse_lighting" }, { - "lighting_space_type_name": "storage_ all_other_large" + "lighting_space_type_name": "audience_seating_area_for_gymnasium_lighting" }, { - "lighting_space_type_name": "storage_hospital_small" + "lighting_space_type_name": "audience_seating_area_for_motion_picture_theater_lighting" }, { - "lighting_space_type_name": "storage_hospital_large" + "lighting_space_type_name": "audience_seating_area_for_penitentiary_lighting" }, { - "lighting_space_type_name": "storage_inactive" + "lighting_space_type_name": "audience_seating_area_for_performing_arts_theater_lighting" }, { - "lighting_space_type_name": "storage_inactive_museum" + "lighting_space_type_name": "audience_seating_area_for_religious_buildings_lighting" }, { - "lighting_space_type_name": "electrical_mechanical" + "lighting_space_type_name": "audience_seating_area_for_sports_arena_lighting" }, { - "lighting_space_type_name": "workshop" + "lighting_space_type_name": "classroom_lecture_training_for_penitentiary_lighting" }, { - "lighting_space_type_name": "gymnasium_playing_area" + "lighting_space_type_name": "corridor_transition_for_hospital_lighting" }, { - "lighting_space_type_name": "gymnasium_exercise_area" + "lighting_space_type_name": "dining_area_for_penitentiary_lighting" }, { - "lighting_space_type_name": "courtroom" + "lighting_space_type_name": "dining_bar_lounge_leisure_general_lighting" }, { - "lighting_space_type_name": "confinement_cells" + "lighting_space_type_name": "dining_cafeteria_fast_food_general_lighting" }, { - "lighting_space_type_name": "judges_chambers" + "lighting_space_type_name": "dining_area_for_family_dining_lighting" }, { - "lighting_space_type_name": "emergency_vehicle_garage" + "lighting_space_type_name": "lobby_for_hotel_lighting" }, { - "lighting_space_type_name": "firestation_sleeping_quarters" + "lighting_space_type_name": "lobby_for_motion_picture_theater_lighting" }, { - "lighting_space_type_name": "post_office_sorting_area" + "lighting_space_type_name": "lobby_for_performing_arts_theater_lighting" }, { - "lighting_space_type_name": "exhibit_convention_center" + "lighting_space_type_name": "lounge_recreation_for_hospital_lighting" }, { - "lighting_space_type_name": "library_cataloging" + "lighting_space_type_name": "office-enclosed_general_lighting" }, { - "lighting_space_type_name": "library_stacks" + "lighting_space_type_name": "office_open_plan_lighting" }, { - "lighting_space_type_name": "library_reading" + "lighting_space_type_name": "automotive_general_lighting" }, { - "lighting_space_type_name": "emergency_room" + "lighting_space_type_name": "convention_center_exhibit_space_general_lighting" }, { - "lighting_space_type_name": "recovery" + "lighting_space_type_name": "library_reading_area_lighting" }, { - "lighting_space_type_name": "nurses_station" + "lighting_space_type_name": "library_stacks_lighting" }, { - "lighting_space_type_name": "exam_treatment" + "lighting_space_type_name": "manufacturing_facility_detailed_manufacturing_area_lighting" }, { - "lighting_space_type_name": "pharmacy" + "lighting_space_type_name": "manufacturing_facility_equipment_room_lighting" }, { - "lighting_space_type_name": "patient_room" + "lighting_space_type_name": "manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting" }, { - "lighting_space_type_name": "operating_room" + "lighting_space_type_name": "manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting" }, { - "lighting_space_type_name": "nursery" + "lighting_space_type_name": "museum_restoration_room_lighting" }, { - "lighting_space_type_name": "medical_supply" + "lighting_space_type_name": "post_office_sorting_area_general_lighting" }, { - "lighting_space_type_name": "physical_therapy" + "lighting_space_type_name": "religious_buildings_fellowship_hall_lighting" }, { - "lighting_space_type_name": "imaging" + "lighting_space_type_name": "religious_buildings_worship_pulpit_choir_lighting" }, { - "lighting_space_type_name": "laundry_washing" + "lighting_space_type_name": "retail_mall_concourse_lighting" }, { - "lighting_space_type_name": "automotive" + "lighting_space_type_name": "transportation_facility_ticket_counter_lighting" }, { - "lighting_space_type_name": "manufacturing_low_bay" + "lighting_space_type_name": "warehouse_storage_area_medium_to_bulky_palletized_items_lighting" }, { - "lighting_space_type_name": "manufacturing_high_bay" - }, - { - "lighting_space_type_name": "detailed_manufacuring" - }, - { - "lighting_space_type_name": "manufacturing_equipment_room" - }, - { - "lighting_space_type_name": "manufacturing_control" - }, - { - "lighting_space_type_name": "manufacturing_extra_high_bay" - }, - { - "lighting_space_type_name": "guest_room" - }, - { - "lighting_space_type_name": "dormitory_living_quarters" - }, - { - "lighting_space_type_name": "museum_exhibit_area" - }, - { - "lighting_space_type_name": "museum_restoration" - }, - { - "lighting_space_type_name": "banking_activity" - }, - { - "lighting_space_type_name": "worship_pulpit_choir_area" - }, - { - "lighting_space_type_name": "fellowship_hall_religious_facility" - }, - { - "lighting_space_type_name": "sales" - }, - { - "lighting_space_type_name": "retail_mall_concourse" - }, - { - "lighting_space_type_name": "retail_dressing_room" - }, - { - "lighting_space_type_name": "sports_arena_ring_sports_area" - }, - { - "lighting_space_type_name": "sports_arena_court_sports_area" - }, - { - "lighting_space_type_name": "sports_arena_indoor_playing_field" - }, - { - "lighting_space_type_name": "sports_arena_playing_area_class_I" - }, - { - "lighting_space_type_name": "sports_arena_playing_area_class_II" - }, - { - "lighting_space_type_name": "sports_arena_playing_area_class_III" - }, - { - "lighting_space_type_name": "sports_arena_playing_area_class_IV" - }, - { - "lighting_space_type_name": "warehouse_fine_storage" - }, - { - "lighting_space_type_name": "warehouse_bulk_storage" - }, - { - "lighting_space_type_name": "parking_area_interior" - }, - { - "lighting_space_type_name": "airport_concourse" - }, - { - "lighting_space_type_name": "baggage_carousel" - }, - { - "lighting_space_type_name": "transportation_ticket_counter" - }, - { - "lighting_space_type_name": "sales_display_type_1" - }, - { - "lighting_space_type_name": "sales_display_type_2" - }, - { - "lighting_space_type_name": "sales_display_type_3" - }, - { - "lighting_space_type_name": "sales_display_type_4" - }, - { - "lighting_space_type_name": "breakroom" - }, - { - "lighting_space_type_name": "copy_print" - }, - { - "lighting_space_type_name": "computer_room" - }, - { - "lighting_space_type_name": "loading_dock" - }, - { - "lighting_space_type_name": "locker_room" - }, - { - "lighting_space_type_name": "seating_area_general" - }, - { - "lighting_space_type_name": "vehicular_maintenance" - }, - { - "lighting_space_type_name": "chapel_visually_impaired" - }, - { - "lighting_space_type_name": "recreation_common_living_visually_impaired" + "lighting_space_type_name": "warehouse_storage_area_smaller_hand-carried_items_lighting" } ] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/support_lighting_technologies.csv b/data/openstudio_standards_data/database_files/support_lighting_technologies.csv new file mode 100644 index 0000000000..00ce10f852 --- /dev/null +++ b/data/openstudio_standards_data/database_files/support_lighting_technologies.csv @@ -0,0 +1,2 @@ +lighting_technology_definition_name,lighting_fraction_to_return_air,lighting_fraction_radiant,lighting_fraction_visible,lighting_fraction_replaceable,lpd_fraction_linear_fluorescent,lpd_fraction_compact_fluorescent,lpd_fraction_high_bay,lpd_fraction_specialty_lighting,lpd_fraction_exit_lighting,compact_fluorescent_lighting_schedule,high_bay_lighting_schedule,specialty_lighting_schedule,exit_lighting_schedule +default,0,0.7,0.2,1,1,0,0,0,0,,,, diff --git a/data/openstudio_standards_data/database_files/support_lighting_technologies.json b/data/openstudio_standards_data/database_files/support_lighting_technologies.json new file mode 100644 index 0000000000..590a32d8b3 --- /dev/null +++ b/data/openstudio_standards_data/database_files/support_lighting_technologies.json @@ -0,0 +1,18 @@ +[ + { + "lighting_technology_definition_name": "default", + "lighting_fraction_to_return_air": 0, + "lighting_fraction_radiant": 0.7, + "lighting_fraction_visible": 0.2, + "lighting_fraction_replaceable": 1, + "lpd_fraction_linear_fluorescent": 1, + "lpd_fraction_compact_fluorescent": 0, + "lpd_fraction_high_bay": 0, + "lpd_fraction_specialty_lighting": 0, + "lpd_fraction_exit_lighting": 0, + "compact_fluorescent_lighting_schedule": null, + "high_bay_lighting_schedule": null, + "specialty_lighting_schedule": null, + "exit_lighting_schedule": null + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/support_schedules.csv b/data/openstudio_standards_data/database_files/support_schedules.csv new file mode 100644 index 0000000000..b5b7ac3689 --- /dev/null +++ b/data/openstudio_standards_data/database_files/support_schedules.csv @@ -0,0 +1,811 @@ +name,category,units,day_types,start_date,end_date,type,hr_1,hr_2,hr_3,hr_4,hr_5,hr_6,hr_7,hr_8,hr_9,hr_10,hr_11,hr_12,hr_13,hr_14,hr_15,hr_16,hr_17,hr_18,hr_19,hr_20,hr_21,hr_22,hr_23,hr_24,annotation +corridor_all_other,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.9,0.5,0,0,0, +corridor_all_other,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.9,0.51,0,0,0, +corridor_all_other,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.9,0.51,0,0,0, +corridor_all_other,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +corridor_all_other,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +corridor_all_other,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +corridor_all_other,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +corridor_all_other,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +corridor_all_other,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +dining_all_other,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0.25,0.9,0.9,0.75,0,0,0,0,0,0,0,0,0, +dining_all_other,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.25,0.25,0.25,0.9,0.9,0.5,0.25,0.25,0,0,0,0,0,0,0, +dining_all_other,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.25,0.25,0.25,0.9,0.9,0.5,0.25,0.25,0,0,0,0,0,0,0, +dining_all_other,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0,0,0, +dining_all_other,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, +dining_all_other,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, +dining_all_other,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.08,0.06,0.06,0.06,0.06,0.06,0.06, +dining_all_other,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.08,0.06,0.06,0.06,0.06,0.06,0.06, +dining_all_other,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.08,0.06,0.06,0.06,0.06,0.06,0.06, +electrical_mechanical,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0,0,0,0,0,0,0, +electrical_mechanical,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +electrical_mechanical,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +electrical_mechanical,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0,0,0,0,0,0,0, +electrical_mechanical,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +electrical_mechanical,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +electrical_mechanical,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.24,0.24,0.24,0.24,0.24,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25, +electrical_mechanical,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.24,0.24,0.24,0.24,0.24,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25, +electrical_mechanical,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.24,0.24,0.24,0.24,0.24,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25, +kitchen,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.5,0.25,0.25,0.9,0.9,0.75,0.25,0,0,0,0,0,0,0,0, +kitchen,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.25,0.25,0.25,0.9,0.75,0.5,0.25,0.25,0,0,0,0,0,0,0, +kitchen,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.25,0.25,0.25,0.9,0.75,0.5,0.25,0.25,0,0,0,0,0,0,0, +kitchen,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0,0, +kitchen,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, +kitchen,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, +kitchen,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.07,0.05,0.05,0.05,0.05,0.05,0.05, +kitchen,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.27,0.06,0.05,0.05,0.05,0.05,0.05, +kitchen,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.27,0.06,0.05,0.05,0.05,0.05,0.05, +laboratory,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +laboratory,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.05,0.125,0.375,0.45,0.45,0.25,0.25,0.45,0.45,0.25,0.25,0,0,0,0,0,0, +laboratory,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.05,0.125,0.625,0.9,0.9,0.75,0.75,0.9,0.825,0.25,0.25,0,0,0,0,0,0, +laboratory,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +laboratory,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0,0,0,0, +laboratory,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0,0,0,0,0,0, +laboratory,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, +laboratory,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.055,0.48,0.48,0.48,0.48,0.48,0.48,0.48,0.48,0.48,0.48,0.055,0.055,0.05,0.05,0.05,0.05, +laboratory,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.055,0.48,0.715,0.9,0.9,0.9,0.83,0.9,0.83,0.48,0.48,0.055,0.055,0.05,0.05,0.05,0.05, +lobby_all_other,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.25,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +lobby_all_other,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0,0,0,0,0,0, +lobby_all_other,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0,0,0,0,0,0, +lobby_all_other,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +lobby_all_other,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0,0,0,0,0,0, +lobby_all_other,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0,0,0,0,0,0, +lobby_all_other,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.53,0.9,0.9,0.05,0.05,0.05,0.05, +lobby_all_other,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.48,0.48,0.48,0.48,0.48,0.48,0.48,0.715,0.52,0.05,0.05,0.05,0.05,0.05,0.05, +lobby_all_other,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.48,0.48,0.48,0.48,0.48,0.48,0.48,0.715,0.52,0.05,0.05,0.05,0.05,0.05,0.05, +locker_room,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.5,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.75,0.25,0,0,0,0,0, +locker_room,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +locker_room,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +locker_room,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +locker_room,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +locker_room,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +locker_room,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +locker_room,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.06,0.05,0.05,0.05, +locker_room,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.06,0.05,0.05,0.05, +lounge_breakroom_all_other,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.25,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +lounge_breakroom_all_other,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, +lounge_breakroom_all_other,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, +lounge_breakroom_all_other,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +lounge_breakroom_all_other,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +lounge_breakroom_all_other,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +lounge_breakroom_all_other,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +lounge_breakroom_all_other,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.53,0.9,0.9,0.9,0.05,0.05,0.05, +lounge_breakroom_all_other,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.53,0.9,0.9,0.9,0.05,0.05,0.05, +office_enclosed_lte_250_sf,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.375,0.825,0.9,0.9,0.625,0.625,0.9,0.9,0.7,0.5,0,0,0,0,0,0, +office_enclosed_lte_250_sf,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +office_enclosed_lte_250_sf,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +office_enclosed_lte_250_sf,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +office_enclosed_lte_250_sf,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +office_enclosed_lte_250_sf,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +office_enclosed_lte_250_sf,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.7,0.05,0.05,0.05,0.05, +office_enclosed_lte_250_sf,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.4,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.4,0.15,0.05,0.05,0.05,0.05, +office_enclosed_lte_250_sf,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.4,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.4,0.15,0.05,0.05,0.05,0.05, +office_enclosed_gt_250_sf,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +office_enclosed_gt_250_sf,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +office_enclosed_gt_250_sf,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +office_enclosed_gt_250_sf,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +office_enclosed_gt_250_sf,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +office_enclosed_gt_250_sf,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +office_enclosed_gt_250_sf,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, +office_enclosed_gt_250_sf,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +office_enclosed_gt_250_sf,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +office_open,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.375,0.825,0.9,0.9,0.625,0.625,0.9,0.9,0.7,0.5,0,0,0,0,0,0, +office_open,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +office_open,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +office_open,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +office_open,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +office_open,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +office_open,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.825,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.825,0.7,0.05,0.05,0.05,0.05, +office_open,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +office_open,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +restroom_all_other,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.375,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.5,0.5,0,0,0, +restroom_all_other,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.375,0.5,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0.25,0,0,0, +restroom_all_other,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.375,0.5,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0.25,0,0,0, +restroom_all_other,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +restroom_all_other,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +restroom_all_other,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +restroom_all_other,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +restroom_all_other,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +restroom_all_other,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +stairwell,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.7,0.9,0.5,0,0,0, +stairwell,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.38,0,0,0, +stairwell,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.38,0,0,0, +stairwell,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +stairwell,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +stairwell,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +stairwell,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +stairwell,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +stairwell,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +storage_50_to_1000_sf_all_other,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.3,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +storage_50_to_1000_sf_all_other,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.1,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0,0,0,0,0,0, +storage_50_to_1000_sf_all_other,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.1,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0,0,0,0,0,0, +storage_50_to_1000_sf_all_other,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +storage_50_to_1000_sf_all_other,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +storage_50_to_1000_sf_all_other,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +storage_50_to_1000_sf_all_other,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +storage_50_to_1000_sf_all_other,Equipment,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +storage_50_to_1000_sf_all_other,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +storage_lt_50_sf_all_other,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.05,0.3,0.825,0.9,0.9,0.825,0.825,0.9,0.9,0.9,0.75,0.05,0.05,0,0,0,0, +storage_lt_50_sf_all_other,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.175,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0,0,0,0,0,0, +storage_lt_50_sf_all_other,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.175,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0,0,0,0,0,0, +storage_lt_50_sf_all_other,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0,0,0,0, +storage_lt_50_sf_all_other,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +storage_lt_50_sf_all_other,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +storage_lt_50_sf_all_other,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +storage_lt_50_sf_all_other,Equipment,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +storage_lt_50_sf_all_other,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +vehicular_maintenance,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.45,0.45,0.5,0.575,0.825,0.9,0.9,0.7,0.7,0.9,0.9,0.7,0.7,0.45,0.45,0.45,0,0,0, +vehicular_maintenance,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, +vehicular_maintenance,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, +vehicular_maintenance,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0.45,0,0,0, +vehicular_maintenance,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, +vehicular_maintenance,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, +vehicular_maintenance,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.045,0.045,0.045,0.045,0.045,0.47,0.47,0.47,0.47,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.47,0.47,0.47,0.47,0.045,0.045,0.045, +vehicular_maintenance,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.045,0.045,0.045,0.045,0.045,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.045,0.045,0.045, +vehicular_maintenance,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.045,0.045,0.045,0.045,0.045,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.045,0.045,0.045, +workshop,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +workshop,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, +workshop,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, +workshop,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +workshop,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +workshop,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +workshop,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.07,0.07,0.05,0.05,0.05,0.05, +workshop,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +workshop,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +atrium_first_three_floors,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0.25,0.25,0.25,0.25,0.25,0, +atrium_first_three_floors,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0.25,0.25,0.25,0.25,0.25,0, +atrium_first_three_floors,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0.25,0.25,0.25,0.25,0.25,0, +atrium_first_three_floors,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +atrium_first_three_floors,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +atrium_first_three_floors,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +atrium_first_three_floors,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +atrium_first_three_floors,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +atrium_first_three_floors,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_convention_center,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_convention_center,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_convention_center,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_convention_center,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_convention_center,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_convention_center,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_convention_center,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_convention_center,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_convention_center,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +classroom_lecture_training_all_other,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +classroom_lecture_training_all_other,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, +classroom_lecture_training_all_other,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, +classroom_lecture_training_all_other,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +classroom_lecture_training_all_other,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +classroom_lecture_training_all_other,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +classroom_lecture_training_all_other,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.07,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.05,0.05,0.05,0.05, +classroom_lecture_training_all_other,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, +classroom_lecture_training_all_other,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, +conference_meeting_multipurpose,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +conference_meeting_multipurpose,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, +conference_meeting_multipurpose,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, +conference_meeting_multipurpose,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +conference_meeting_multipurpose,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +conference_meeting_multipurpose,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +conference_meeting_multipurpose,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +conference_meeting_multipurpose,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, +conference_meeting_multipurpose,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.9,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, +exhibit_convention_center,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +exhibit_convention_center,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +exhibit_convention_center,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +exhibit_convention_center,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +exhibit_convention_center,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +exhibit_convention_center,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +exhibit_convention_center,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +exhibit_convention_center,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +exhibit_convention_center,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +gymnasium_exercise_area,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +gymnasium_exercise_area,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +gymnasium_exercise_area,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +gymnasium_exercise_area,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +gymnasium_exercise_area,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +gymnasium_exercise_area,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +gymnasium_exercise_area,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +gymnasium_exercise_area,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +gymnasium_exercise_area,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +gymnasium_playing_area,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0.25,0,0,0,0,0, +gymnasium_playing_area,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +gymnasium_playing_area,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +gymnasium_playing_area,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +gymnasium_playing_area,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +gymnasium_playing_area,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +gymnasium_playing_area,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.475,0.475,0.475,0.05,0.05,0.05, +gymnasium_playing_area,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.83,0.9,0.9,0.83,0.83,0.9,0.9,0.9,0.83,0.475,0.475,0.475,0.05,0.05,0.05, +gymnasium_playing_area,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.83,0.9,0.9,0.83,0.83,0.9,0.9,0.9,0.83,0.475,0.475,0.475,0.05,0.05,0.05, +laundry_washing,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0,0,0,0,0,0, +laundry_washing,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, +laundry_washing,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, +laundry_washing,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +laundry_washing,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, +laundry_washing,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, +laundry_washing,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.06,0.06,0.06,0.05,0.05,0.05,0.05, +laundry_washing,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.06,0.06,0.06,0.05,0.05,0.05,0.05, +laundry_washing,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.06,0.06,0.06,0.05,0.05,0.05,0.05, +lobby_elevator,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +lobby_elevator,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, +lobby_elevator,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, +lobby_elevator,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +lobby_elevator,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +lobby_elevator,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +lobby_elevator,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, +lobby_elevator,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +lobby_elevator,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +nurses_station,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +nurses_station,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +nurses_station,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +nurses_station,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +nurses_station,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +nurses_station,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +nurses_station,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, +nurses_station,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, +nurses_station,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, +post_office_sorting_area,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +post_office_sorting_area,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +post_office_sorting_area,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +post_office_sorting_area,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +post_office_sorting_area,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +post_office_sorting_area,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +post_office_sorting_area,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +post_office_sorting_area,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +post_office_sorting_area,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +sales,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +sales,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +sales,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +sales,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +sales,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +sales,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +sales,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +sales,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +sales,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +sports_arena_playing_area_class_iv,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +sports_arena_playing_area_class_iv,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +sports_arena_playing_area_class_iv,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +sports_arena_playing_area_class_iv,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +sports_arena_playing_area_class_iv,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +sports_arena_playing_area_class_iv,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +sports_arena_playing_area_class_iv,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +sports_arena_playing_area_class_iv,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +sports_arena_playing_area_class_iv,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +audience_seating_all_other,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.125,0.25,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.625,0.25,0,0,0,0,0, +audience_seating_all_other,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.625,0.9,0.9,0.825,0.75,0.9,0.825,0.45,0.375,0,0,0,0,0,0, +audience_seating_all_other,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.625,0.9,0.9,0.825,0.75,0.9,0.825,0.45,0.375,0,0,0,0,0,0, +audience_seating_all_other,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +audience_seating_all_other,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0,0,0,0,0,0, +audience_seating_all_other,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0,0,0,0,0,0, +audience_seating_all_other,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.475,0.05,0.05,0.05, +audience_seating_all_other,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.645,0.9,0.9,0.83,0.76,0.9,0.83,0.475,0.405,0.05,0.05,0.05,0.05,0.05,0.05, +audience_seating_all_other,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.83,0.9,0.9,0.83,0.83,0.9,0.9,0.9,0.405,0.05,0.05,0.05,0.05,0.05,0.05, +confinement_cells,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0.125,0.125,0.125,0.125,0.125,0.125,0.125,0.125,0.125,0,0,0,0,0.25,0.75, +confinement_cells,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, +confinement_cells,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, +confinement_cells,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0,0,0.9,0.45, +confinement_cells,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.45, +confinement_cells,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.45, +confinement_cells,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +confinement_cells,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +confinement_cells,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +courtroom,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +courtroom,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, +courtroom,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, +courtroom,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +courtroom,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +courtroom,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +courtroom,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.07,0.07,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.07,0.07,0.07,0.07,0.05,0.05,0.05, +courtroom,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.07,0.07,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.07,0.07,0.07,0.07,0.05,0.05,0.05, +courtroom,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.07,0.07,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.07,0.07,0.07,0.07,0.05,0.05,0.05, +judges_chambers,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +judges_chambers,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +judges_chambers,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +judges_chambers,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +judges_chambers,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +judges_chambers,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +judges_chambers,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +judges_chambers,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +judges_chambers,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +library_stacks,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +library_stacks,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0,0,0,0,0,0, +library_stacks,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0,0,0,0,0,0, +library_stacks,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +library_stacks,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.5,0.9,0.9,0.9,0.75,0.9,0.75,0,0,0,0,0,0,0,0, +library_stacks,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.5,0.9,0.9,0.9,0.75,0.9,0.75,0,0,0,0,0,0,0,0, +library_stacks,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +library_stacks,Equipment,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +library_stacks,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +storage_inactive,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.3,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.3,0,0,0,0,0,0, +storage_inactive,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0,0,0,0,0,0,0, +storage_inactive,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0,0,0,0,0,0,0, +storage_inactive,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +storage_inactive,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, +storage_inactive,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, +storage_inactive,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +storage_inactive,Equipment,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +storage_inactive,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +dining_bar_lounge_leisure,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, +dining_bar_lounge_leisure,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, +dining_bar_lounge_leisure,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, +dining_bar_lounge_leisure,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +dining_bar_lounge_leisure,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +dining_bar_lounge_leisure,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +dining_bar_lounge_leisure,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +dining_bar_lounge_leisure,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +dining_bar_lounge_leisure,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +dining_cafeteria_fast_food,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, +dining_cafeteria_fast_food,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, +dining_cafeteria_fast_food,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, +dining_cafeteria_fast_food,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +dining_cafeteria_fast_food,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +dining_cafeteria_fast_food,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +dining_cafeteria_fast_food,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +dining_cafeteria_fast_food,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +dining_cafeteria_fast_food,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +dining_family,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, +dining_family,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, +dining_family,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, +dining_family,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +dining_family,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +dining_family,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +dining_family,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +dining_family,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +dining_family,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +computer_room,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0.75,0.75,0.75,0.5,0.5,0, +computer_room,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0.75,0.75,0.75,0.5,0.5,0, +computer_room,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0.75,0.75,0.75,0.5,0.5,0, +computer_room,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +computer_room,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +computer_room,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +computer_room,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05, +computer_room,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05, +computer_room,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05, +dormitory_living_quarters,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75,0.9, +dormitory_living_quarters,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75,0.9, +dormitory_living_quarters,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75,0.9, +dormitory_living_quarters,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.5,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.25, +dormitory_living_quarters,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.5,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.25, +dormitory_living_quarters,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.5,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.25, +dormitory_living_quarters,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +dormitory_living_quarters,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +dormitory_living_quarters,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +audience_seating_exercise_center,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_exercise_center,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_exercise_center,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_exercise_center,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_exercise_center,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_exercise_center,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_exercise_center,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_exercise_center,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_exercise_center,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +exam_treatment,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +exam_treatment,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +exam_treatment,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +exam_treatment,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +exam_treatment,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +exam_treatment,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +exam_treatment,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, +exam_treatment,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +exam_treatment,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +library_reading,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, +library_reading,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0,0,0,0,0,0,0, +library_reading,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0,0,0,0,0,0,0, +library_reading,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +library_reading,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, +library_reading,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, +library_reading,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +library_reading,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +library_reading,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +emergency_vehicle_garage,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0,0,0,0,0,0,0, +emergency_vehicle_garage,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +emergency_vehicle_garage,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +emergency_vehicle_garage,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0,0,0,0,0,0,0, +emergency_vehicle_garage,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +emergency_vehicle_garage,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +emergency_vehicle_garage,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +emergency_vehicle_garage,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +emergency_vehicle_garage,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +firestation_sleeping_quarters,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, +firestation_sleeping_quarters,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, +firestation_sleeping_quarters,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, +firestation_sleeping_quarters,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0, +firestation_sleeping_quarters,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0, +firestation_sleeping_quarters,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0, +firestation_sleeping_quarters,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +firestation_sleeping_quarters,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +firestation_sleeping_quarters,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +parking_area_interior,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0.125,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.705,0.9,0.575,0.125,0,0,0, +parking_area_interior,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.58,0.46,0.58,0.75,0.75,0.705,0.46,0.46,0.5,0.25,0,0,0,0,0, +parking_area_interior,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.58,0.46,0.58,0.75,0.75,0.705,0.46,0.46,0.5,0.25,0,0,0,0,0, +parking_area_interior,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0,0,0, +parking_area_interior,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +parking_area_interior,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +parking_area_interior,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +parking_area_interior,Equipment,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +parking_area_interior,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +audience_seating_gymnasium,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_gymnasium,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_gymnasium,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_gymnasium,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_gymnasium,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_gymnasium,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_gymnasium,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_gymnasium,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_gymnasium,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +emergency_room,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.575,0.7,0.9,0.9,0.9,0.825,0.825,0.9,0.9,0.9,0.7,0.575,0.45,0.45,0,0,0, +emergency_room,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, +emergency_room,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, +emergency_room,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0,0,0, +emergency_room,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, +emergency_room,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, +emergency_room,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.475,0.475,0.475,0.05,0.05,0.05, +emergency_room,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.05,0.05,0.05, +emergency_room,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.05,0.05,0.05, +patient_room,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.575,0.7,0.9,0.9,0.9,0.825,0.825,0.9,0.9,0.9,0.7,0.575,0.45,0.45,0.45,0.45,0.45, +patient_room,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45, +patient_room,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45, +patient_room,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.15,0.8,0.9,0.9,0.9,0.9,0.9,0.9,0.8,0.6,0.6,0.8,0.9,0.45,0.45,0.45,0.35,0.15, +patient_room,Lighting,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.15,0.35,0.45,0.45,0.45,0.45,0.45,0.45,0.35,0.15,0.15,0.35,0.45,0.45,0.45,0.45,0.35,0.15, +patient_room,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.15,0.35,0.45,0.45,0.45,0.45,0.45,0.45,0.35,0.15,0.15,0.35,0.45,0.45,0.45,0.45,0.35,0.15, +patient_room,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.475,0.475,0.475,0.475,0.475,0.195, +patient_room,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.195, +patient_room,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.195, +pharmacy,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +pharmacy,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +pharmacy,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +pharmacy,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +pharmacy,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +pharmacy,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +pharmacy,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, +pharmacy,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +pharmacy,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +corridor_hospital,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +corridor_hospital,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +corridor_hospital,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +corridor_hospital,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +corridor_hospital,Lighting,,Sat,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +corridor_hospital,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +corridor_hospital,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +corridor_hospital,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +corridor_hospital,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +fellowship_hall_religious_facility,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +fellowship_hall_religious_facility,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, +fellowship_hall_religious_facility,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, +fellowship_hall_religious_facility,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +fellowship_hall_religious_facility,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, +fellowship_hall_religious_facility,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, +fellowship_hall_religious_facility,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +fellowship_hall_religious_facility,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.05,0.05,0.05, +fellowship_hall_religious_facility,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.05,0.05,0.05, +lounge_breakroom_healthcare_facility,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +lounge_breakroom_healthcare_facility,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +lounge_breakroom_healthcare_facility,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +lounge_breakroom_healthcare_facility,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +lounge_breakroom_healthcare_facility,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +lounge_breakroom_healthcare_facility,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +lounge_breakroom_healthcare_facility,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, +lounge_breakroom_healthcare_facility,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, +lounge_breakroom_healthcare_facility,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, +operating_room,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +operating_room,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +operating_room,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +operating_room,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.18,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.58,0.45,0.18, +operating_room,Lighting,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.18,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.58,0.45,0.18, +operating_room,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.18,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.58,0.45,0.18, +operating_room,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +operating_room,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +operating_room,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +physical_therapy,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +physical_therapy,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +physical_therapy,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +physical_therapy,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +physical_therapy,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +physical_therapy,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +physical_therapy,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, +physical_therapy,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, +physical_therapy,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, +storage_50_to_1000_sf_hospital,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, +storage_50_to_1000_sf_hospital,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, +storage_50_to_1000_sf_hospital,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, +storage_50_to_1000_sf_hospital,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, +storage_50_to_1000_sf_hospital,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, +storage_50_to_1000_sf_hospital,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, +storage_50_to_1000_sf_hospital,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +storage_50_to_1000_sf_hospital,Equipment,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +storage_50_to_1000_sf_hospital,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +storage_lt_50_sf_hospital,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, +storage_lt_50_sf_hospital,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, +storage_lt_50_sf_hospital,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, +storage_lt_50_sf_hospital,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, +storage_lt_50_sf_hospital,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, +storage_lt_50_sf_hospital,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, +storage_lt_50_sf_hospital,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +storage_lt_50_sf_hospital,Equipment,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +storage_lt_50_sf_hospital,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +guest_room,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75,0.9, +guest_room,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75,0.9, +guest_room,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75,0.9, +guest_room,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9, +guest_room,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9, +guest_room,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9, +guest_room,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +guest_room,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +guest_room,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +lobby_hotel,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.3, +lobby_hotel,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.3, +lobby_hotel,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.3, +lobby_hotel,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +lobby_hotel,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +lobby_hotel,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +lobby_hotel,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +lobby_hotel,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +lobby_hotel,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +library_cataloging,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +library_cataloging,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +library_cataloging,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +library_cataloging,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +library_cataloging,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +library_cataloging,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +library_cataloging,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +library_cataloging,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +library_cataloging,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +museum_exhibit_area,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.375,0.45,0.45,0.375,0.375,0.45,0.45,0.7,0.5,0.125,0,0,0,0,0, +museum_exhibit_area,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.375,0.45,0.45,0.375,0.375,0.45,0.45,0.7,0.5,0.125,0,0,0,0,0, +museum_exhibit_area,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.375,0.45,0.45,0.375,0.375,0.45,0.45,0.7,0.5,0.125,0,0,0,0,0, +museum_exhibit_area,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45, +museum_exhibit_area,Lighting,,Sat,1-Jan,31-Dec,Hourly,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45, +museum_exhibit_area,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45, +museum_exhibit_area,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.055,0.055,0.055,0.055,0.055,0.05, +museum_exhibit_area,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.055,0.055,0.055,0.055,0.055,0.05, +museum_exhibit_area,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.055,0.055,0.055,0.055,0.055,0.05, +corridor_manufacturing_facility,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +corridor_manufacturing_facility,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +corridor_manufacturing_facility,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +corridor_manufacturing_facility,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +corridor_manufacturing_facility,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +corridor_manufacturing_facility,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +corridor_manufacturing_facility,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.04,0.04,0.04,0.04,0.04,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.04,0.04,0.04, +corridor_manufacturing_facility,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.04,0.04,0.04,0.04,0.04,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.04,0.04,0.04, +corridor_manufacturing_facility,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.04,0.04,0.04,0.04,0.04,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.04,0.04,0.04, +manufacturing_equipment_room,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +manufacturing_equipment_room,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +manufacturing_equipment_room,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +manufacturing_equipment_room,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +manufacturing_equipment_room,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +manufacturing_equipment_room,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +manufacturing_equipment_room,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +manufacturing_equipment_room,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +manufacturing_equipment_room,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +manufacturing_low_bay,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +manufacturing_low_bay,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +manufacturing_low_bay,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +manufacturing_low_bay,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +manufacturing_low_bay,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +manufacturing_low_bay,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +manufacturing_low_bay,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +manufacturing_low_bay,Equipment,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +manufacturing_low_bay,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +performing_arts_dressing_room,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.825,0,0,0,0,0,0, +performing_arts_dressing_room,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0,0,0,0,0,0, +performing_arts_dressing_room,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0,0,0,0,0,0, +performing_arts_dressing_room,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +performing_arts_dressing_room,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0,0,0,0,0,0, +performing_arts_dressing_room,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0,0,0,0,0,0, +performing_arts_dressing_room,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.045,0.045,0.045,0.045,0.055,0.055,0.055,0.055,0.48,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.475,0.475,0.475,0.045,0.045,0.045, +performing_arts_dressing_room,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.045,0.045,0.045,0.045,0.055,0.055,0.055,0.055,0.48,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.48,0.055,0.055,0.055,0.045,0.045,0.045, +performing_arts_dressing_room,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.045,0.045,0.045,0.045,0.045,0.045,0.045,0.045,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.48,0.055,0.055,0.055,0.045,0.045,0.045, +audience_seating_auditorium,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_auditorium,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_auditorium,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_auditorium,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_auditorium,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_auditorium,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_auditorium,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_auditorium,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_auditorium,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_motion_picture_theater,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_motion_picture_theater,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_motion_picture_theater,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_motion_picture_theater,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_motion_picture_theater,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_motion_picture_theater,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_motion_picture_theater,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_motion_picture_theater,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_motion_picture_theater,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +lobby_motion_picture_theater,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +lobby_motion_picture_theater,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +lobby_motion_picture_theater,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +lobby_motion_picture_theater,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +lobby_motion_picture_theater,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +lobby_motion_picture_theater,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +lobby_motion_picture_theater,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +lobby_motion_picture_theater,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +lobby_motion_picture_theater,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +dwelling_unit,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, +dwelling_unit,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, +dwelling_unit,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, +dwelling_unit,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0,0,0,0,0,0,0,0,0,0.2,0.2,0.2,0.2,0, +dwelling_unit,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0,0,0,0,0,0,0,0,0,0.2,0.2,0.2,0.2,0, +dwelling_unit,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0,0,0,0,0,0,0,0,0,0.2,0.2,0.2,0.2,0, +dwelling_unit,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +dwelling_unit,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +dwelling_unit,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +museum_restoration,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +museum_restoration,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +museum_restoration,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +museum_restoration,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +museum_restoration,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +museum_restoration,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +museum_restoration,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +museum_restoration,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +museum_restoration,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +banking_activity,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +banking_activity,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +banking_activity,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +banking_activity,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +banking_activity,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +banking_activity,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +banking_activity,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, +banking_activity,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +banking_activity,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +warehouse_fine_storage,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.45,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.45,0,0,0,0,0,0, +warehouse_fine_storage,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.45,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.45,0,0,0,0,0,0, +warehouse_fine_storage,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.45,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.45,0,0,0,0,0,0, +warehouse_fine_storage,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.45,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.45,0,0,0,0,0,0, +warehouse_fine_storage,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.45,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.45,0,0,0,0,0,0, +warehouse_fine_storage,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.45,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.45,0,0,0,0,0,0, +warehouse_fine_storage,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +warehouse_fine_storage,Equipment,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +warehouse_fine_storage,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +classroom_lecture_training_penitentiary,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +classroom_lecture_training_penitentiary,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +classroom_lecture_training_penitentiary,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +classroom_lecture_training_penitentiary,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +classroom_lecture_training_penitentiary,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +classroom_lecture_training_penitentiary,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +classroom_lecture_training_penitentiary,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.04,0.04,0.04,0.04,0.04,0.04,0.04, +classroom_lecture_training_penitentiary,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04, +classroom_lecture_training_penitentiary,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04, +dining_penitentiary,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0.25,0.9,0.9,0.25,0,0.25,0.9,0.9,0.5,0,0,0.5,0.9,0.9,0.5,0,0,0, +dining_penitentiary,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0.25,0.9,0.9,0.25,0,0.25,0.9,0.9,0.5,0,0,0.5,0.9,0.9,0.5,0,0,0, +dining_penitentiary,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0.25,0.9,0.9,0.25,0,0.25,0.9,0.9,0.5,0,0,0.5,0.9,0.9,0.5,0,0,0, +dining_penitentiary,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0,0.9,0.9,0.9,0.9,0,0,0.9,0.9,0.9,0.9,0,0,0, +dining_penitentiary,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0,0.9,0.9,0.9,0.9,0,0,0.9,0.9,0.9,0.9,0,0,0, +dining_penitentiary,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0,0.9,0.9,0.9,0.9,0,0,0.9,0.9,0.9,0.9,0,0,0, +dining_penitentiary,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.9,0.9,0.3,0.07,0.3,0.9,0.9,0.54,0.07,0.07,0.54,0.9,0.9,0.54,0.07,0.07,0.07, +dining_penitentiary,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.9,0.9,0.3,0.07,0.3,0.9,0.9,0.54,0.07,0.07,0.54,0.9,0.9,0.54,0.07,0.07,0.07, +dining_penitentiary,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.9,0.9,0.3,0.07,0.3,0.9,0.9,0.54,0.07,0.07,0.54,0.9,0.9,0.54,0.07,0.07,0.07, +audience_seating_performing_arts_theater,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_performing_arts_theater,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_performing_arts_theater,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_performing_arts_theater,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_performing_arts_theater,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_performing_arts_theater,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_performing_arts_theater,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_performing_arts_theater,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_performing_arts_theater,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +lobby_performing_arts_theater,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +lobby_performing_arts_theater,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +lobby_performing_arts_theater,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +lobby_performing_arts_theater,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +lobby_performing_arts_theater,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +lobby_performing_arts_theater,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +lobby_performing_arts_theater,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +lobby_performing_arts_theater,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +lobby_performing_arts_theater,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +audience_seating_religious_facility,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +audience_seating_religious_facility,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +audience_seating_religious_facility,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +audience_seating_religious_facility,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +audience_seating_religious_facility,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +audience_seating_religious_facility,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +audience_seating_religious_facility,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +audience_seating_religious_facility,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +audience_seating_religious_facility,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +worship_pulpit_choir_area,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +worship_pulpit_choir_area,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +worship_pulpit_choir_area,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +worship_pulpit_choir_area,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +worship_pulpit_choir_area,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +worship_pulpit_choir_area,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +worship_pulpit_choir_area,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +worship_pulpit_choir_area,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +worship_pulpit_choir_area,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +classroom_lecture_training_preschool_to_12th,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +classroom_lecture_training_preschool_to_12th,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +classroom_lecture_training_preschool_to_12th,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +classroom_lecture_training_preschool_to_12th,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +classroom_lecture_training_preschool_to_12th,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +classroom_lecture_training_preschool_to_12th,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +classroom_lecture_training_preschool_to_12th,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +classroom_lecture_training_preschool_to_12th,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +classroom_lecture_training_preschool_to_12th,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +sports_arena_playing_area_class_ii,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.125,0.25,0.9,0.9,0.9,0.825,0.825,0.9,0.9,0.9,0.7,0.575,0.45,0.45,0,0,0, +sports_arena_playing_area_class_ii,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.825,0.9,0.9,0.825,0.825,0.9,0.9,0.9,0.825,0.45,0.45,0.45,0,0,0, +sports_arena_playing_area_class_ii,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.825,0.9,0.9,0.825,0.825,0.9,0.9,0.9,0.825,0.45,0.45,0.45,0,0,0, +sports_arena_playing_area_class_ii,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0,0,0, +sports_arena_playing_area_class_ii,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0.45,0,0,0, +sports_arena_playing_area_class_ii,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0.45,0,0,0, +sports_arena_playing_area_class_ii,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.475,0.05,0.05,0.05, +sports_arena_playing_area_class_ii,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.83,0.9,0.9,0.83,0.83,0.9,0.9,0.9,0.83,0.475,0.475,0.475,0.05,0.05,0.05, +sports_arena_playing_area_class_ii,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.83,0.9,0.9,0.83,0.83,0.9,0.9,0.9,0.83,0.475,0.475,0.475,0.05,0.05,0.05, +audience_seating_sports_arena,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_sports_arena,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_sports_arena,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_sports_arena,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_sports_arena,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_sports_arena,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_sports_arena,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_sports_arena,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_sports_arena,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +airport_concourse,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0.25,0.25,0.25,0.25,0.25, +airport_concourse,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0.25,0.25,0.25,0.25,0.25, +airport_concourse,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0.25,0.25,0.25,0.25,0.25, +airport_concourse,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +airport_concourse,Lighting,,Sat,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +airport_concourse,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +airport_concourse,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +airport_concourse,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +airport_concourse,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +atrium_lt_20_ft_height,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_lt_20_ft_height,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_lt_20_ft_height,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_lt_20_ft_height,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_lt_20_ft_height,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_lt_20_ft_height,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_lt_20_ft_height,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +atrium_lt_20_ft_height,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +atrium_lt_20_ft_height,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +atrium_gt_40_ft_height,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_gt_40_ft_height,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_gt_40_ft_height,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_gt_40_ft_height,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_gt_40_ft_height,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_gt_40_ft_height,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_gt_40_ft_height,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +atrium_gt_40_ft_height,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +atrium_gt_40_ft_height,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +atrium_gte_20_ft_and_lte_40_ft_in_height,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_gte_20_ft_and_lte_40_ft_in_height,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_gte_20_ft_and_lte_40_ft_in_height,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_gte_20_ft_and_lte_40_ft_in_height,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_gte_20_ft_and_lte_40_ft_in_height,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_gte_20_ft_and_lte_40_ft_in_height,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_gte_20_ft_and_lte_40_ft_in_height,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +atrium_gte_20_ft_and_lte_40_ft_in_height,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +atrium_gte_20_ft_and_lte_40_ft_in_height,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +baggage_carousel,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0.25,0.25,0.25,0.25,0.25, +baggage_carousel,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0.25,0.25,0.25,0.25,0.25, +baggage_carousel,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0.25,0.25,0.25,0.25,0.25, +baggage_carousel,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +baggage_carousel,Lighting,,Sat,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +baggage_carousel,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +baggage_carousel,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +baggage_carousel,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +baggage_carousel,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +seating_area_general,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25,0.25, +seating_area_general,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25,0.25, +seating_area_general,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25,0.25, +seating_area_general,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +seating_area_general,Lighting,,Sat,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +seating_area_general,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +seating_area_general,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +seating_area_general,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +seating_area_general,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +transportation_ticket_counter,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +transportation_ticket_counter,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +transportation_ticket_counter,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +transportation_ticket_counter,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +transportation_ticket_counter,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +transportation_ticket_counter,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +transportation_ticket_counter,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25,0.25,0.25, +transportation_ticket_counter,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25,0.25,0.25, +transportation_ticket_counter,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25,0.25,0.25, +warehouse_bulk_storage,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +warehouse_bulk_storage,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +warehouse_bulk_storage,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +warehouse_bulk_storage,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +warehouse_bulk_storage,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +warehouse_bulk_storage,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +warehouse_bulk_storage,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +warehouse_bulk_storage,Equipment,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +warehouse_bulk_storage,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, diff --git a/data/openstudio_standards_data/database_files/support_schedules.json b/data/openstudio_standards_data/database_files/support_schedules.json new file mode 100644 index 0000000000..6b4d769dea --- /dev/null +++ b/data/openstudio_standards_data/database_files/support_schedules.json @@ -0,0 +1,27542 @@ +[ + { + "name": "corridor_all_other", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.5, + "hr_20": 0.9, + "hr_21": 0.5, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "corridor_all_other", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.5, + "hr_20": 0.9, + "hr_21": 0.51, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "corridor_all_other", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.5, + "hr_20": 0.9, + "hr_21": 0.51, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "corridor_all_other", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "corridor_all_other", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "corridor_all_other", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "corridor_all_other", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "corridor_all_other", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "corridor_all_other", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "dining_all_other", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0.25, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.75, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_all_other", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.25, + "hr_11": 0.25, + "hr_12": 0.25, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.5, + "hr_16": 0.25, + "hr_17": 0.25, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_all_other", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.25, + "hr_11": 0.25, + "hr_12": 0.25, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.5, + "hr_16": 0.25, + "hr_17": 0.25, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_all_other", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_all_other", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_all_other", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_all_other", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.06, + "hr_2": 0.06, + "hr_3": 0.06, + "hr_4": 0.06, + "hr_5": 0.06, + "hr_6": 0.06, + "hr_7": 0.06, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.08, + "hr_19": 0.06, + "hr_20": 0.06, + "hr_21": 0.06, + "hr_22": 0.06, + "hr_23": 0.06, + "hr_24": 0.06, + "annotation": null + }, + { + "name": "dining_all_other", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.06, + "hr_2": 0.06, + "hr_3": 0.06, + "hr_4": 0.06, + "hr_5": 0.06, + "hr_6": 0.06, + "hr_7": 0.06, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.08, + "hr_19": 0.06, + "hr_20": 0.06, + "hr_21": 0.06, + "hr_22": 0.06, + "hr_23": 0.06, + "hr_24": 0.06, + "annotation": null + }, + { + "name": "dining_all_other", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.06, + "hr_2": 0.06, + "hr_3": 0.06, + "hr_4": 0.06, + "hr_5": 0.06, + "hr_6": 0.06, + "hr_7": 0.06, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.08, + "hr_19": 0.06, + "hr_20": 0.06, + "hr_21": 0.06, + "hr_22": 0.06, + "hr_23": 0.06, + "hr_24": 0.06, + "annotation": null + }, + { + "name": "electrical_mechanical", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.01, + "hr_11": 0.01, + "hr_12": 0.01, + "hr_13": 0.01, + "hr_14": 0.01, + "hr_15": 0.01, + "hr_16": 0.01, + "hr_17": 0.01, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "electrical_mechanical", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "electrical_mechanical", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "electrical_mechanical", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.01, + "hr_11": 0.01, + "hr_12": 0.01, + "hr_13": 0.01, + "hr_14": 0.01, + "hr_15": 0.01, + "hr_16": 0.01, + "hr_17": 0.01, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "electrical_mechanical", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "electrical_mechanical", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "electrical_mechanical", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.24, + "hr_2": 0.24, + "hr_3": 0.24, + "hr_4": 0.24, + "hr_5": 0.24, + "hr_6": 0.25, + "hr_7": 0.25, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.25, + "hr_23": 0.25, + "hr_24": 0.25, + "annotation": null + }, + { + "name": "electrical_mechanical", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.24, + "hr_2": 0.24, + "hr_3": 0.24, + "hr_4": 0.24, + "hr_5": 0.24, + "hr_6": 0.25, + "hr_7": 0.25, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.25, + "hr_23": 0.25, + "hr_24": 0.25, + "annotation": null + }, + { + "name": "electrical_mechanical", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.24, + "hr_2": 0.24, + "hr_3": 0.24, + "hr_4": 0.24, + "hr_5": 0.24, + "hr_6": 0.25, + "hr_7": 0.25, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.25, + "hr_23": 0.25, + "hr_24": 0.25, + "annotation": null + }, + { + "name": "kitchen", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.5, + "hr_11": 0.25, + "hr_12": 0.25, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.75, + "hr_16": 0.25, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "kitchen", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.25, + "hr_11": 0.25, + "hr_12": 0.25, + "hr_13": 0.9, + "hr_14": 0.75, + "hr_15": 0.5, + "hr_16": 0.25, + "hr_17": 0.25, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "kitchen", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.25, + "hr_11": 0.25, + "hr_12": 0.25, + "hr_13": 0.9, + "hr_14": 0.75, + "hr_15": 0.5, + "hr_16": 0.25, + "hr_17": 0.25, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "kitchen", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "kitchen", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "kitchen", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "kitchen", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.07, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "kitchen", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.27, + "hr_19": 0.06, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "kitchen", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.27, + "hr_19": 0.06, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "laboratory", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "laboratory", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.05, + "hr_9": 0.125, + "hr_10": 0.375, + "hr_11": 0.45, + "hr_12": 0.45, + "hr_13": 0.25, + "hr_14": 0.25, + "hr_15": 0.45, + "hr_16": 0.45, + "hr_17": 0.25, + "hr_18": 0.25, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "laboratory", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.05, + "hr_9": 0.125, + "hr_10": 0.625, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.825, + "hr_17": 0.25, + "hr_18": 0.25, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "laboratory", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "laboratory", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.45, + "hr_9": 0.45, + "hr_10": 0.45, + "hr_11": 0.45, + "hr_12": 0.45, + "hr_13": 0.45, + "hr_14": 0.45, + "hr_15": 0.45, + "hr_16": 0.45, + "hr_17": 0.45, + "hr_18": 0.45, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "laboratory", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.45, + "hr_9": 0.45, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.45, + "hr_18": 0.45, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "laboratory", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "laboratory", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.055, + "hr_9": 0.48, + "hr_10": 0.48, + "hr_11": 0.48, + "hr_12": 0.48, + "hr_13": 0.48, + "hr_14": 0.48, + "hr_15": 0.48, + "hr_16": 0.48, + "hr_17": 0.48, + "hr_18": 0.48, + "hr_19": 0.055, + "hr_20": 0.055, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "laboratory", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.055, + "hr_9": 0.48, + "hr_10": 0.715, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.83, + "hr_15": 0.9, + "hr_16": 0.83, + "hr_17": 0.48, + "hr_18": 0.48, + "hr_19": 0.055, + "hr_20": 0.055, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "lobby_all_other", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.25, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lobby_all_other", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lobby_all_other", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lobby_all_other", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lobby_all_other", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lobby_all_other", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lobby_all_other", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.53, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "lobby_all_other", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.48, + "hr_11": 0.48, + "hr_12": 0.48, + "hr_13": 0.48, + "hr_14": 0.48, + "hr_15": 0.48, + "hr_16": 0.48, + "hr_17": 0.715, + "hr_18": 0.52, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "lobby_all_other", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.48, + "hr_11": 0.48, + "hr_12": 0.48, + "hr_13": 0.48, + "hr_14": 0.48, + "hr_15": 0.48, + "hr_16": 0.48, + "hr_17": 0.715, + "hr_18": 0.52, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "locker_room", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0.25, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "locker_room", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "locker_room", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "locker_room", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "locker_room", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "locker_room", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "locker_room", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "locker_room", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.06, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.06, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "locker_room", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.06, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "lounge_breakroom_all_other", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.25, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lounge_breakroom_all_other", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lounge_breakroom_all_other", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lounge_breakroom_all_other", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lounge_breakroom_all_other", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lounge_breakroom_all_other", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lounge_breakroom_all_other", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "lounge_breakroom_all_other", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.53, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "lounge_breakroom_all_other", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.53, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "office_enclosed_lte_250_sf", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.1, + "hr_9": 0.375, + "hr_10": 0.825, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.625, + "hr_14": 0.625, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.7, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "office_enclosed_lte_250_sf", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.1, + "hr_9": 0.25, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.5, + "hr_14": 0.5, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "office_enclosed_lte_250_sf", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.1, + "hr_9": 0.25, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.5, + "hr_14": 0.5, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "office_enclosed_lte_250_sf", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "office_enclosed_lte_250_sf", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "office_enclosed_lte_250_sf", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "office_enclosed_lte_250_sf", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.7, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "office_enclosed_lte_250_sf", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.4, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.4, + "hr_20": 0.15, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "office_enclosed_lte_250_sf", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.4, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.4, + "hr_20": 0.15, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "office_enclosed_gt_250_sf", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "office_enclosed_gt_250_sf", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.1, + "hr_9": 0.25, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.5, + "hr_14": 0.5, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "office_enclosed_gt_250_sf", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.1, + "hr_9": 0.25, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.5, + "hr_14": 0.5, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "office_enclosed_gt_250_sf", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "office_enclosed_gt_250_sf", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "office_enclosed_gt_250_sf", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "office_enclosed_gt_250_sf", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "office_enclosed_gt_250_sf", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "office_enclosed_gt_250_sf", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "office_open", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.1, + "hr_9": 0.375, + "hr_10": 0.825, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.625, + "hr_14": 0.625, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.7, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "office_open", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.1, + "hr_9": 0.25, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.5, + "hr_14": 0.5, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "office_open", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.1, + "hr_9": 0.25, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.5, + "hr_14": 0.5, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "office_open", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "office_open", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "office_open", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "office_open", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.825, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.825, + "hr_20": 0.7, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "office_open", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "office_open", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "restroom_all_other", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.375, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.5, + "hr_20": 0.5, + "hr_21": 0.5, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "restroom_all_other", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.375, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.5, + "hr_20": 0.25, + "hr_21": 0.25, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "restroom_all_other", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.375, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.5, + "hr_20": 0.25, + "hr_21": 0.25, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "restroom_all_other", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "restroom_all_other", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "restroom_all_other", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "restroom_all_other", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "restroom_all_other", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "restroom_all_other", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "stairwell", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.7, + "hr_20": 0.9, + "hr_21": 0.5, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "stairwell", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.38, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "stairwell", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.38, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "stairwell", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "stairwell", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "stairwell", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "stairwell", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "stairwell", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "stairwell", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "storage_50_to_1000_sf_all_other", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.3, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_50_to_1000_sf_all_other", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.1, + "hr_10": 0.3, + "hr_11": 0.3, + "hr_12": 0.3, + "hr_13": 0.3, + "hr_14": 0.3, + "hr_15": 0.3, + "hr_16": 0.3, + "hr_17": 0.3, + "hr_18": 0.3, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_50_to_1000_sf_all_other", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.1, + "hr_10": 0.3, + "hr_11": 0.3, + "hr_12": 0.3, + "hr_13": 0.3, + "hr_14": 0.3, + "hr_15": 0.3, + "hr_16": 0.3, + "hr_17": 0.3, + "hr_18": 0.3, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_50_to_1000_sf_all_other", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_50_to_1000_sf_all_other", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_50_to_1000_sf_all_other", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_50_to_1000_sf_all_other", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_50_to_1000_sf_all_other", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_50_to_1000_sf_all_other", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_lt_50_sf_all_other", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.05, + "hr_9": 0.3, + "hr_10": 0.825, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.825, + "hr_14": 0.825, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_lt_50_sf_all_other", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.175, + "hr_10": 0.3, + "hr_11": 0.3, + "hr_12": 0.3, + "hr_13": 0.3, + "hr_14": 0.3, + "hr_15": 0.3, + "hr_16": 0.3, + "hr_17": 0.3, + "hr_18": 0.3, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_lt_50_sf_all_other", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.175, + "hr_10": 0.3, + "hr_11": 0.3, + "hr_12": 0.3, + "hr_13": 0.3, + "hr_14": 0.3, + "hr_15": 0.3, + "hr_16": 0.3, + "hr_17": 0.3, + "hr_18": 0.3, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_lt_50_sf_all_other", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.45, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.45, + "hr_20": 0.45, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_lt_50_sf_all_other", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_lt_50_sf_all_other", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_lt_50_sf_all_other", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_lt_50_sf_all_other", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_lt_50_sf_all_other", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "vehicular_maintenance", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0.45, + "hr_7": 0.45, + "hr_8": 0.5, + "hr_9": 0.575, + "hr_10": 0.825, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.7, + "hr_14": 0.7, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.7, + "hr_18": 0.7, + "hr_19": 0.45, + "hr_20": 0.45, + "hr_21": 0.45, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "vehicular_maintenance", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0.45, + "hr_7": 0.45, + "hr_8": 0.45, + "hr_9": 0.45, + "hr_10": 0.45, + "hr_11": 0.45, + "hr_12": 0.45, + "hr_13": 0.45, + "hr_14": 0.45, + "hr_15": 0.45, + "hr_16": 0.45, + "hr_17": 0.45, + "hr_18": 0.45, + "hr_19": 0.45, + "hr_20": 0.45, + "hr_21": 0.45, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "vehicular_maintenance", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0.45, + "hr_7": 0.45, + "hr_8": 0.45, + "hr_9": 0.45, + "hr_10": 0.45, + "hr_11": 0.45, + "hr_12": 0.45, + "hr_13": 0.45, + "hr_14": 0.45, + "hr_15": 0.45, + "hr_16": 0.45, + "hr_17": 0.45, + "hr_18": 0.45, + "hr_19": 0.45, + "hr_20": 0.45, + "hr_21": 0.45, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "vehicular_maintenance", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0.45, + "hr_7": 0.45, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.45, + "hr_20": 0.45, + "hr_21": 0.45, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "vehicular_maintenance", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0.45, + "hr_7": 0.45, + "hr_8": 0.45, + "hr_9": 0.45, + "hr_10": 0.45, + "hr_11": 0.45, + "hr_12": 0.45, + "hr_13": 0.45, + "hr_14": 0.45, + "hr_15": 0.45, + "hr_16": 0.45, + "hr_17": 0.45, + "hr_18": 0.45, + "hr_19": 0.45, + "hr_20": 0.45, + "hr_21": 0.45, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "vehicular_maintenance", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0.45, + "hr_7": 0.45, + "hr_8": 0.45, + "hr_9": 0.45, + "hr_10": 0.45, + "hr_11": 0.45, + "hr_12": 0.45, + "hr_13": 0.45, + "hr_14": 0.45, + "hr_15": 0.45, + "hr_16": 0.45, + "hr_17": 0.45, + "hr_18": 0.45, + "hr_19": 0.45, + "hr_20": 0.45, + "hr_21": 0.45, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "vehicular_maintenance", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.045, + "hr_2": 0.045, + "hr_3": 0.045, + "hr_4": 0.045, + "hr_5": 0.045, + "hr_6": 0.47, + "hr_7": 0.47, + "hr_8": 0.47, + "hr_9": 0.47, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.47, + "hr_19": 0.47, + "hr_20": 0.47, + "hr_21": 0.47, + "hr_22": 0.045, + "hr_23": 0.045, + "hr_24": 0.045, + "annotation": null + }, + { + "name": "vehicular_maintenance", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.045, + "hr_2": 0.045, + "hr_3": 0.045, + "hr_4": 0.045, + "hr_5": 0.045, + "hr_6": 0.47, + "hr_7": 0.47, + "hr_8": 0.47, + "hr_9": 0.47, + "hr_10": 0.47, + "hr_11": 0.47, + "hr_12": 0.47, + "hr_13": 0.47, + "hr_14": 0.47, + "hr_15": 0.47, + "hr_16": 0.47, + "hr_17": 0.47, + "hr_18": 0.47, + "hr_19": 0.47, + "hr_20": 0.47, + "hr_21": 0.47, + "hr_22": 0.045, + "hr_23": 0.045, + "hr_24": 0.045, + "annotation": null + }, + { + "name": "vehicular_maintenance", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.045, + "hr_2": 0.045, + "hr_3": 0.045, + "hr_4": 0.045, + "hr_5": 0.045, + "hr_6": 0.47, + "hr_7": 0.47, + "hr_8": 0.47, + "hr_9": 0.47, + "hr_10": 0.47, + "hr_11": 0.47, + "hr_12": 0.47, + "hr_13": 0.47, + "hr_14": 0.47, + "hr_15": 0.47, + "hr_16": 0.47, + "hr_17": 0.47, + "hr_18": 0.47, + "hr_19": 0.47, + "hr_20": 0.47, + "hr_21": 0.47, + "hr_22": 0.045, + "hr_23": 0.045, + "hr_24": 0.045, + "annotation": null + }, + { + "name": "workshop", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.1, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "workshop", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "workshop", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "workshop", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "workshop", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "workshop", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "workshop", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.07, + "hr_20": 0.07, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "workshop", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "workshop", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "atrium_first_three_floors", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0.25, + "hr_20": 0.25, + "hr_21": 0.25, + "hr_22": 0.25, + "hr_23": 0.25, + "hr_24": 0, + "annotation": null + }, + { + "name": "atrium_first_three_floors", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0.25, + "hr_20": 0.25, + "hr_21": 0.25, + "hr_22": 0.25, + "hr_23": 0.25, + "hr_24": 0, + "annotation": null + }, + { + "name": "atrium_first_three_floors", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0.25, + "hr_20": 0.25, + "hr_21": 0.25, + "hr_22": 0.25, + "hr_23": 0.25, + "hr_24": 0, + "annotation": null + }, + { + "name": "atrium_first_three_floors", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "atrium_first_three_floors", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "atrium_first_three_floors", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "atrium_first_three_floors", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.06, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "atrium_first_three_floors", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.06, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "atrium_first_three_floors", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.06, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "audience_seating_convention_center", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.67, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_convention_center", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.67, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_convention_center", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.67, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_convention_center", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_convention_center", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_convention_center", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_convention_center", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.06, + "hr_2": 0.06, + "hr_3": 0.06, + "hr_4": 0.06, + "hr_5": 0.06, + "hr_6": 0.06, + "hr_7": 0.06, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.06, + "hr_11": 0.06, + "hr_12": 0.06, + "hr_13": 0.06, + "hr_14": 0.06, + "hr_15": 0.06, + "hr_16": 0.06, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "audience_seating_convention_center", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.06, + "hr_2": 0.06, + "hr_3": 0.06, + "hr_4": 0.06, + "hr_5": 0.06, + "hr_6": 0.06, + "hr_7": 0.06, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.06, + "hr_11": 0.06, + "hr_12": 0.06, + "hr_13": 0.06, + "hr_14": 0.06, + "hr_15": 0.06, + "hr_16": 0.06, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "audience_seating_convention_center", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.06, + "hr_2": 0.06, + "hr_3": 0.06, + "hr_4": 0.06, + "hr_5": 0.06, + "hr_6": 0.06, + "hr_7": 0.06, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.06, + "hr_11": 0.06, + "hr_12": 0.06, + "hr_13": 0.06, + "hr_14": 0.06, + "hr_15": 0.06, + "hr_16": 0.06, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "classroom_lecture_training_all_other", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "classroom_lecture_training_all_other", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "classroom_lecture_training_all_other", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "classroom_lecture_training_all_other", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "classroom_lecture_training_all_other", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "classroom_lecture_training_all_other", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "classroom_lecture_training_all_other", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.07, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.25, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "classroom_lecture_training_all_other", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.76, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.76, + "hr_14": 0.76, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.76, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "classroom_lecture_training_all_other", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.76, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "conference_meeting_multipurpose", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.1, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "conference_meeting_multipurpose", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "conference_meeting_multipurpose", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "conference_meeting_multipurpose", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "conference_meeting_multipurpose", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "conference_meeting_multipurpose", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "conference_meeting_multipurpose", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "conference_meeting_multipurpose", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.76, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.76, + "hr_14": 0.76, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.76, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "conference_meeting_multipurpose", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.76, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.76, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.76, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "exhibit_convention_center", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "exhibit_convention_center", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "exhibit_convention_center", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "exhibit_convention_center", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "exhibit_convention_center", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "exhibit_convention_center", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "exhibit_convention_center", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "exhibit_convention_center", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "exhibit_convention_center", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "gymnasium_exercise_area", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "gymnasium_exercise_area", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "gymnasium_exercise_area", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "gymnasium_exercise_area", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "gymnasium_exercise_area", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "gymnasium_exercise_area", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "gymnasium_exercise_area", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "gymnasium_exercise_area", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "gymnasium_exercise_area", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "gymnasium_playing_area", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0.25, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "gymnasium_playing_area", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "gymnasium_playing_area", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "gymnasium_playing_area", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "gymnasium_playing_area", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "gymnasium_playing_area", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "gymnasium_playing_area", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.475, + "hr_20": 0.475, + "hr_21": 0.475, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "gymnasium_playing_area", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.83, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.83, + "hr_14": 0.83, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.83, + "hr_19": 0.475, + "hr_20": 0.475, + "hr_21": 0.475, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "gymnasium_playing_area", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.83, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.83, + "hr_14": 0.83, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.83, + "hr_19": 0.475, + "hr_20": 0.475, + "hr_21": 0.475, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "laundry_washing", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "laundry_washing", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "laundry_washing", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "laundry_washing", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "laundry_washing", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "laundry_washing", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "laundry_washing", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.06, + "hr_19": 0.06, + "hr_20": 0.06, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "laundry_washing", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.06, + "hr_19": 0.06, + "hr_20": 0.06, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "laundry_washing", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.06, + "hr_19": 0.06, + "hr_20": 0.06, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "lobby_elevator", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lobby_elevator", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lobby_elevator", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lobby_elevator", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lobby_elevator", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lobby_elevator", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lobby_elevator", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "lobby_elevator", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "lobby_elevator", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "nurses_station", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.1, + "hr_9": 0.25, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.5, + "hr_14": 0.5, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "nurses_station", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.1, + "hr_9": 0.25, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.5, + "hr_14": 0.5, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "nurses_station", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.1, + "hr_9": 0.25, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.5, + "hr_14": 0.5, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "nurses_station", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "nurses_station", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "nurses_station", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "nurses_station", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "nurses_station", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "nurses_station", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "post_office_sorting_area", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "post_office_sorting_area", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "post_office_sorting_area", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "post_office_sorting_area", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "post_office_sorting_area", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "post_office_sorting_area", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "post_office_sorting_area", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "post_office_sorting_area", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "post_office_sorting_area", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "sales", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.1, + "hr_9": 0.25, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "sales", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.1, + "hr_9": 0.25, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.5, + "hr_14": 0.5, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "sales", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.1, + "hr_9": 0.25, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.5, + "hr_14": 0.5, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "sales", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "sales", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "sales", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "sales", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "sales", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "sales", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "sports_arena_playing_area_class_iv", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "sports_arena_playing_area_class_iv", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "sports_arena_playing_area_class_iv", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "sports_arena_playing_area_class_iv", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "sports_arena_playing_area_class_iv", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "sports_arena_playing_area_class_iv", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "sports_arena_playing_area_class_iv", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "sports_arena_playing_area_class_iv", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "sports_arena_playing_area_class_iv", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "audience_seating_all_other", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.125, + "hr_9": 0.25, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.625, + "hr_19": 0.25, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_all_other", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.625, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.825, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.825, + "hr_17": 0.45, + "hr_18": 0.375, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_all_other", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.625, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.825, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.825, + "hr_17": 0.45, + "hr_18": 0.375, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_all_other", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.45, + "hr_9": 0.45, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_all_other", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.45, + "hr_18": 0.45, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_all_other", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.45, + "hr_18": 0.45, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_all_other", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.475, + "hr_9": 0.475, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.475, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "audience_seating_all_other", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.645, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.83, + "hr_14": 0.76, + "hr_15": 0.9, + "hr_16": 0.83, + "hr_17": 0.475, + "hr_18": 0.405, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "audience_seating_all_other", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.83, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.83, + "hr_14": 0.83, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.405, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "confinement_cells", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.5, + "hr_9": 0.25, + "hr_10": 0.125, + "hr_11": 0.125, + "hr_12": 0.125, + "hr_13": 0.125, + "hr_14": 0.125, + "hr_15": 0.125, + "hr_16": 0.125, + "hr_17": 0.125, + "hr_18": 0.125, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0.25, + "hr_24": 0.75, + "annotation": null + }, + { + "name": "confinement_cells", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.5, + "hr_9": 0.25, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0.25, + "hr_24": 0.75, + "annotation": null + }, + { + "name": "confinement_cells", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.5, + "hr_9": 0.25, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0.25, + "hr_24": 0.75, + "annotation": null + }, + { + "name": "confinement_cells", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.45, + "hr_11": 0.45, + "hr_12": 0.45, + "hr_13": 0.45, + "hr_14": 0.45, + "hr_15": 0.45, + "hr_16": 0.45, + "hr_17": 0.45, + "hr_18": 0.45, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0.9, + "hr_24": 0.45, + "annotation": null + }, + { + "name": "confinement_cells", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0.9, + "hr_24": 0.45, + "annotation": null + }, + { + "name": "confinement_cells", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0.9, + "hr_24": 0.45, + "annotation": null + }, + { + "name": "confinement_cells", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.07, + "hr_2": 0.07, + "hr_3": 0.07, + "hr_4": 0.07, + "hr_5": 0.07, + "hr_6": 0.07, + "hr_7": 0.07, + "hr_8": 0.53, + "hr_9": 0.9, + "hr_10": 0.53, + "hr_11": 0.07, + "hr_12": 0.07, + "hr_13": 0.07, + "hr_14": 0.07, + "hr_15": 0.07, + "hr_16": 0.07, + "hr_17": 0.07, + "hr_18": 0.3, + "hr_19": 0.53, + "hr_20": 0.77, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.77, + "hr_24": 0.3, + "annotation": null + }, + { + "name": "confinement_cells", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.07, + "hr_2": 0.07, + "hr_3": 0.07, + "hr_4": 0.07, + "hr_5": 0.07, + "hr_6": 0.07, + "hr_7": 0.07, + "hr_8": 0.53, + "hr_9": 0.9, + "hr_10": 0.53, + "hr_11": 0.07, + "hr_12": 0.07, + "hr_13": 0.07, + "hr_14": 0.07, + "hr_15": 0.07, + "hr_16": 0.07, + "hr_17": 0.07, + "hr_18": 0.3, + "hr_19": 0.53, + "hr_20": 0.77, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.77, + "hr_24": 0.3, + "annotation": null + }, + { + "name": "confinement_cells", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.07, + "hr_2": 0.07, + "hr_3": 0.07, + "hr_4": 0.07, + "hr_5": 0.07, + "hr_6": 0.07, + "hr_7": 0.07, + "hr_8": 0.53, + "hr_9": 0.9, + "hr_10": 0.53, + "hr_11": 0.07, + "hr_12": 0.07, + "hr_13": 0.07, + "hr_14": 0.07, + "hr_15": 0.07, + "hr_16": 0.07, + "hr_17": 0.07, + "hr_18": 0.3, + "hr_19": 0.53, + "hr_20": 0.77, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.77, + "hr_24": 0.3, + "annotation": null + }, + { + "name": "courtroom", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "courtroom", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "courtroom", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "courtroom", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "courtroom", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "courtroom", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "courtroom", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.07, + "hr_9": 0.07, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.07, + "hr_19": 0.07, + "hr_20": 0.07, + "hr_21": 0.07, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "courtroom", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.07, + "hr_9": 0.07, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.07, + "hr_19": 0.07, + "hr_20": 0.07, + "hr_21": 0.07, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "courtroom", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.07, + "hr_9": 0.07, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.07, + "hr_19": 0.07, + "hr_20": 0.07, + "hr_21": 0.07, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "judges_chambers", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.1, + "hr_9": 0.25, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.5, + "hr_14": 0.5, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "judges_chambers", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "judges_chambers", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "judges_chambers", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "judges_chambers", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "judges_chambers", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "judges_chambers", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "judges_chambers", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.05, + "hr_11": 0.05, + "hr_12": 0.05, + "hr_13": 0.05, + "hr_14": 0.05, + "hr_15": 0.05, + "hr_16": 0.05, + "hr_17": 0.05, + "hr_18": 0.05, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "judges_chambers", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.05, + "hr_11": 0.05, + "hr_12": 0.05, + "hr_13": 0.05, + "hr_14": 0.05, + "hr_15": 0.05, + "hr_16": 0.05, + "hr_17": 0.05, + "hr_18": 0.05, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "library_stacks", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "library_stacks", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.25, + "hr_11": 0.25, + "hr_12": 0.25, + "hr_13": 0.25, + "hr_14": 0.25, + "hr_15": 0.25, + "hr_16": 0.25, + "hr_17": 0.25, + "hr_18": 0.25, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "library_stacks", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.25, + "hr_11": 0.25, + "hr_12": 0.25, + "hr_13": 0.25, + "hr_14": 0.25, + "hr_15": 0.25, + "hr_16": 0.25, + "hr_17": 0.25, + "hr_18": 0.25, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "library_stacks", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "library_stacks", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.5, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.75, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "library_stacks", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.5, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.75, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "library_stacks", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "library_stacks", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "library_stacks", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_inactive", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.3, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.3, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_inactive", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.3, + "hr_11": 0.3, + "hr_12": 0.3, + "hr_13": 0.3, + "hr_14": 0.3, + "hr_15": 0.3, + "hr_16": 0.3, + "hr_17": 0.3, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_inactive", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.3, + "hr_11": 0.3, + "hr_12": 0.3, + "hr_13": 0.3, + "hr_14": 0.3, + "hr_15": 0.3, + "hr_16": 0.3, + "hr_17": 0.3, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_inactive", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_inactive", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_inactive", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_inactive", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_inactive", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_inactive", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_bar_lounge_leisure", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.25, + "hr_10": 0.5, + "hr_11": 0.5, + "hr_12": 0.5, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.5, + "hr_16": 0.25, + "hr_17": 0.25, + "hr_18": 0.25, + "hr_19": 0.5, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.5, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_bar_lounge_leisure", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.25, + "hr_10": 0.5, + "hr_11": 0.5, + "hr_12": 0.5, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.5, + "hr_16": 0.25, + "hr_17": 0.25, + "hr_18": 0.25, + "hr_19": 0.5, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.5, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_bar_lounge_leisure", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.25, + "hr_10": 0.5, + "hr_11": 0.5, + "hr_12": 0.5, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.5, + "hr_16": 0.25, + "hr_17": 0.25, + "hr_18": 0.25, + "hr_19": 0.5, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.5, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_bar_lounge_leisure", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_bar_lounge_leisure", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_bar_lounge_leisure", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_bar_lounge_leisure", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "dining_bar_lounge_leisure", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "dining_bar_lounge_leisure", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "dining_cafeteria_fast_food", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.25, + "hr_10": 0.5, + "hr_11": 0.5, + "hr_12": 0.5, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.5, + "hr_16": 0.25, + "hr_17": 0.25, + "hr_18": 0.25, + "hr_19": 0.5, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.5, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_cafeteria_fast_food", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.25, + "hr_10": 0.5, + "hr_11": 0.5, + "hr_12": 0.5, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.5, + "hr_16": 0.25, + "hr_17": 0.25, + "hr_18": 0.25, + "hr_19": 0.5, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.5, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_cafeteria_fast_food", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.25, + "hr_10": 0.5, + "hr_11": 0.5, + "hr_12": 0.5, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.5, + "hr_16": 0.25, + "hr_17": 0.25, + "hr_18": 0.25, + "hr_19": 0.5, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.5, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_cafeteria_fast_food", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_cafeteria_fast_food", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_cafeteria_fast_food", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_cafeteria_fast_food", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "dining_cafeteria_fast_food", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "dining_cafeteria_fast_food", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "dining_family", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.25, + "hr_10": 0.5, + "hr_11": 0.5, + "hr_12": 0.5, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.5, + "hr_16": 0.25, + "hr_17": 0.25, + "hr_18": 0.25, + "hr_19": 0.5, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.5, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_family", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.25, + "hr_10": 0.5, + "hr_11": 0.5, + "hr_12": 0.5, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.5, + "hr_16": 0.25, + "hr_17": 0.25, + "hr_18": 0.25, + "hr_19": 0.5, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.5, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_family", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.25, + "hr_10": 0.5, + "hr_11": 0.5, + "hr_12": 0.5, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.5, + "hr_16": 0.25, + "hr_17": 0.25, + "hr_18": 0.25, + "hr_19": 0.5, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.5, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_family", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_family", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_family", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_family", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "dining_family", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "dining_family", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "computer_room", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0.75, + "hr_20": 0.75, + "hr_21": 0.75, + "hr_22": 0.5, + "hr_23": 0.5, + "hr_24": 0, + "annotation": null + }, + { + "name": "computer_room", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0.75, + "hr_20": 0.75, + "hr_21": 0.75, + "hr_22": 0.5, + "hr_23": 0.5, + "hr_24": 0, + "annotation": null + }, + { + "name": "computer_room", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0.75, + "hr_20": 0.75, + "hr_21": 0.75, + "hr_22": 0.5, + "hr_23": 0.5, + "hr_24": 0, + "annotation": null + }, + { + "name": "computer_room", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "computer_room", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "computer_room", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "computer_room", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "computer_room", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "computer_room", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "dormitory_living_quarters", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.5, + "hr_9": 0.25, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0.25, + "hr_23": 0.75, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "dormitory_living_quarters", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.5, + "hr_9": 0.25, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0.25, + "hr_23": 0.75, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "dormitory_living_quarters", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.5, + "hr_9": 0.25, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0.25, + "hr_23": 0.75, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "dormitory_living_quarters", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.5, + "hr_9": 0.9, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.25, + "annotation": null + }, + { + "name": "dormitory_living_quarters", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.5, + "hr_9": 0.9, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.25, + "annotation": null + }, + { + "name": "dormitory_living_quarters", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.5, + "hr_9": 0.9, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.25, + "annotation": null + }, + { + "name": "dormitory_living_quarters", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.07, + "hr_2": 0.07, + "hr_3": 0.07, + "hr_4": 0.07, + "hr_5": 0.07, + "hr_6": 0.07, + "hr_7": 0.07, + "hr_8": 0.53, + "hr_9": 0.9, + "hr_10": 0.53, + "hr_11": 0.07, + "hr_12": 0.07, + "hr_13": 0.07, + "hr_14": 0.07, + "hr_15": 0.07, + "hr_16": 0.07, + "hr_17": 0.07, + "hr_18": 0.3, + "hr_19": 0.53, + "hr_20": 0.77, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.77, + "hr_24": 0.3, + "annotation": null + }, + { + "name": "dormitory_living_quarters", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.07, + "hr_2": 0.07, + "hr_3": 0.07, + "hr_4": 0.07, + "hr_5": 0.07, + "hr_6": 0.07, + "hr_7": 0.07, + "hr_8": 0.53, + "hr_9": 0.9, + "hr_10": 0.53, + "hr_11": 0.07, + "hr_12": 0.07, + "hr_13": 0.07, + "hr_14": 0.07, + "hr_15": 0.07, + "hr_16": 0.07, + "hr_17": 0.07, + "hr_18": 0.3, + "hr_19": 0.53, + "hr_20": 0.77, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.77, + "hr_24": 0.3, + "annotation": null + }, + { + "name": "dormitory_living_quarters", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.07, + "hr_2": 0.07, + "hr_3": 0.07, + "hr_4": 0.07, + "hr_5": 0.07, + "hr_6": 0.07, + "hr_7": 0.07, + "hr_8": 0.53, + "hr_9": 0.9, + "hr_10": 0.53, + "hr_11": 0.07, + "hr_12": 0.07, + "hr_13": 0.07, + "hr_14": 0.07, + "hr_15": 0.07, + "hr_16": 0.07, + "hr_17": 0.07, + "hr_18": 0.3, + "hr_19": 0.53, + "hr_20": 0.77, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.77, + "hr_24": 0.3, + "annotation": null + }, + { + "name": "audience_seating_exercise_center", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.67, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_exercise_center", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.67, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_exercise_center", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.67, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_exercise_center", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_exercise_center", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_exercise_center", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_exercise_center", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.06, + "hr_2": 0.06, + "hr_3": 0.06, + "hr_4": 0.06, + "hr_5": 0.06, + "hr_6": 0.06, + "hr_7": 0.06, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.06, + "hr_11": 0.06, + "hr_12": 0.06, + "hr_13": 0.06, + "hr_14": 0.06, + "hr_15": 0.06, + "hr_16": 0.06, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "audience_seating_exercise_center", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.06, + "hr_2": 0.06, + "hr_3": 0.06, + "hr_4": 0.06, + "hr_5": 0.06, + "hr_6": 0.06, + "hr_7": 0.06, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.06, + "hr_11": 0.06, + "hr_12": 0.06, + "hr_13": 0.06, + "hr_14": 0.06, + "hr_15": 0.06, + "hr_16": 0.06, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "audience_seating_exercise_center", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.06, + "hr_2": 0.06, + "hr_3": 0.06, + "hr_4": 0.06, + "hr_5": 0.06, + "hr_6": 0.06, + "hr_7": 0.06, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.06, + "hr_11": 0.06, + "hr_12": 0.06, + "hr_13": 0.06, + "hr_14": 0.06, + "hr_15": 0.06, + "hr_16": 0.06, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "exam_treatment", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "exam_treatment", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.1, + "hr_9": 0.25, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.5, + "hr_14": 0.5, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "exam_treatment", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.1, + "hr_9": 0.25, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.5, + "hr_14": 0.5, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "exam_treatment", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "exam_treatment", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "exam_treatment", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "exam_treatment", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "exam_treatment", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.05, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "exam_treatment", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.05, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "library_reading", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "library_reading", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "library_reading", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "library_reading", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "library_reading", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "library_reading", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "library_reading", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "library_reading", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.05, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "library_reading", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.05, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "emergency_vehicle_garage", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.01, + "hr_11": 0.01, + "hr_12": 0.01, + "hr_13": 0.01, + "hr_14": 0.01, + "hr_15": 0.01, + "hr_16": 0.01, + "hr_17": 0.01, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "emergency_vehicle_garage", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "emergency_vehicle_garage", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "emergency_vehicle_garage", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.01, + "hr_11": 0.01, + "hr_12": 0.01, + "hr_13": 0.01, + "hr_14": 0.01, + "hr_15": 0.01, + "hr_16": 0.01, + "hr_17": 0.01, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "emergency_vehicle_garage", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "emergency_vehicle_garage", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "emergency_vehicle_garage", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "emergency_vehicle_garage", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "emergency_vehicle_garage", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "firestation_sleeping_quarters", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.5, + "hr_9": 0.25, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0.25, + "hr_24": 0.75, + "annotation": null + }, + { + "name": "firestation_sleeping_quarters", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.5, + "hr_9": 0.25, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0.25, + "hr_24": 0.75, + "annotation": null + }, + { + "name": "firestation_sleeping_quarters", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.5, + "hr_9": 0.25, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0.25, + "hr_24": 0.75, + "annotation": null + }, + { + "name": "firestation_sleeping_quarters", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "firestation_sleeping_quarters", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "firestation_sleeping_quarters", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "firestation_sleeping_quarters", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.07, + "hr_2": 0.07, + "hr_3": 0.07, + "hr_4": 0.07, + "hr_5": 0.07, + "hr_6": 0.07, + "hr_7": 0.07, + "hr_8": 0.53, + "hr_9": 0.9, + "hr_10": 0.53, + "hr_11": 0.07, + "hr_12": 0.07, + "hr_13": 0.07, + "hr_14": 0.07, + "hr_15": 0.07, + "hr_16": 0.07, + "hr_17": 0.07, + "hr_18": 0.3, + "hr_19": 0.53, + "hr_20": 0.77, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.77, + "hr_24": 0.3, + "annotation": null + }, + { + "name": "firestation_sleeping_quarters", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.07, + "hr_2": 0.07, + "hr_3": 0.07, + "hr_4": 0.07, + "hr_5": 0.07, + "hr_6": 0.07, + "hr_7": 0.07, + "hr_8": 0.53, + "hr_9": 0.9, + "hr_10": 0.53, + "hr_11": 0.07, + "hr_12": 0.07, + "hr_13": 0.07, + "hr_14": 0.07, + "hr_15": 0.07, + "hr_16": 0.07, + "hr_17": 0.07, + "hr_18": 0.3, + "hr_19": 0.53, + "hr_20": 0.77, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.77, + "hr_24": 0.3, + "annotation": null + }, + { + "name": "firestation_sleeping_quarters", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.07, + "hr_2": 0.07, + "hr_3": 0.07, + "hr_4": 0.07, + "hr_5": 0.07, + "hr_6": 0.07, + "hr_7": 0.07, + "hr_8": 0.53, + "hr_9": 0.9, + "hr_10": 0.53, + "hr_11": 0.07, + "hr_12": 0.07, + "hr_13": 0.07, + "hr_14": 0.07, + "hr_15": 0.07, + "hr_16": 0.07, + "hr_17": 0.07, + "hr_18": 0.3, + "hr_19": 0.53, + "hr_20": 0.77, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.77, + "hr_24": 0.3, + "annotation": null + }, + { + "name": "parking_area_interior", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0.125, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.705, + "hr_19": 0.9, + "hr_20": 0.575, + "hr_21": 0.125, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "parking_area_interior", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.58, + "hr_11": 0.46, + "hr_12": 0.58, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.705, + "hr_16": 0.46, + "hr_17": 0.46, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "parking_area_interior", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.58, + "hr_11": 0.46, + "hr_12": 0.58, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.705, + "hr_16": 0.46, + "hr_17": 0.46, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "parking_area_interior", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0.45, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.45, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "parking_area_interior", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "parking_area_interior", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "parking_area_interior", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "parking_area_interior", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "parking_area_interior", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_gymnasium", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.67, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_gymnasium", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.67, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_gymnasium", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.67, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_gymnasium", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_gymnasium", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_gymnasium", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_gymnasium", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.06, + "hr_2": 0.06, + "hr_3": 0.06, + "hr_4": 0.06, + "hr_5": 0.06, + "hr_6": 0.06, + "hr_7": 0.06, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.06, + "hr_11": 0.06, + "hr_12": 0.06, + "hr_13": 0.06, + "hr_14": 0.06, + "hr_15": 0.06, + "hr_16": 0.06, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "audience_seating_gymnasium", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.06, + "hr_2": 0.06, + "hr_3": 0.06, + "hr_4": 0.06, + "hr_5": 0.06, + "hr_6": 0.06, + "hr_7": 0.06, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.06, + "hr_11": 0.06, + "hr_12": 0.06, + "hr_13": 0.06, + "hr_14": 0.06, + "hr_15": 0.06, + "hr_16": 0.06, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "audience_seating_gymnasium", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.06, + "hr_2": 0.06, + "hr_3": 0.06, + "hr_4": 0.06, + "hr_5": 0.06, + "hr_6": 0.06, + "hr_7": 0.06, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.06, + "hr_11": 0.06, + "hr_12": 0.06, + "hr_13": 0.06, + "hr_14": 0.06, + "hr_15": 0.06, + "hr_16": 0.06, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "emergency_room", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.575, + "hr_9": 0.7, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.825, + "hr_14": 0.825, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.7, + "hr_19": 0.575, + "hr_20": 0.45, + "hr_21": 0.45, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "emergency_room", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.45, + "hr_9": 0.45, + "hr_10": 0.45, + "hr_11": 0.45, + "hr_12": 0.45, + "hr_13": 0.45, + "hr_14": 0.45, + "hr_15": 0.45, + "hr_16": 0.45, + "hr_17": 0.45, + "hr_18": 0.45, + "hr_19": 0.45, + "hr_20": 0.45, + "hr_21": 0.45, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "emergency_room", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.45, + "hr_9": 0.45, + "hr_10": 0.45, + "hr_11": 0.45, + "hr_12": 0.45, + "hr_13": 0.45, + "hr_14": 0.45, + "hr_15": 0.45, + "hr_16": 0.45, + "hr_17": 0.45, + "hr_18": 0.45, + "hr_19": 0.45, + "hr_20": 0.45, + "hr_21": 0.45, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "emergency_room", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.45, + "hr_21": 0.45, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "emergency_room", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.45, + "hr_9": 0.45, + "hr_10": 0.45, + "hr_11": 0.45, + "hr_12": 0.45, + "hr_13": 0.45, + "hr_14": 0.45, + "hr_15": 0.45, + "hr_16": 0.45, + "hr_17": 0.45, + "hr_18": 0.45, + "hr_19": 0.45, + "hr_20": 0.45, + "hr_21": 0.45, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "emergency_room", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.45, + "hr_9": 0.45, + "hr_10": 0.45, + "hr_11": 0.45, + "hr_12": 0.45, + "hr_13": 0.45, + "hr_14": 0.45, + "hr_15": 0.45, + "hr_16": 0.45, + "hr_17": 0.45, + "hr_18": 0.45, + "hr_19": 0.45, + "hr_20": 0.45, + "hr_21": 0.45, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "emergency_room", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.475, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.475, + "hr_20": 0.475, + "hr_21": 0.475, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "emergency_room", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.475, + "hr_9": 0.475, + "hr_10": 0.475, + "hr_11": 0.475, + "hr_12": 0.475, + "hr_13": 0.475, + "hr_14": 0.475, + "hr_15": 0.475, + "hr_16": 0.475, + "hr_17": 0.475, + "hr_18": 0.475, + "hr_19": 0.475, + "hr_20": 0.475, + "hr_21": 0.475, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "emergency_room", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.475, + "hr_9": 0.475, + "hr_10": 0.475, + "hr_11": 0.475, + "hr_12": 0.475, + "hr_13": 0.475, + "hr_14": 0.475, + "hr_15": 0.475, + "hr_16": 0.475, + "hr_17": 0.475, + "hr_18": 0.475, + "hr_19": 0.475, + "hr_20": 0.475, + "hr_21": 0.475, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "patient_room", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.45, + "hr_2": 0.45, + "hr_3": 0.45, + "hr_4": 0.45, + "hr_5": 0.45, + "hr_6": 0.45, + "hr_7": 0.45, + "hr_8": 0.575, + "hr_9": 0.7, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.825, + "hr_14": 0.825, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.7, + "hr_19": 0.575, + "hr_20": 0.45, + "hr_21": 0.45, + "hr_22": 0.45, + "hr_23": 0.45, + "hr_24": 0.45, + "annotation": null + }, + { + "name": "patient_room", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.45, + "hr_2": 0.45, + "hr_3": 0.45, + "hr_4": 0.45, + "hr_5": 0.45, + "hr_6": 0.45, + "hr_7": 0.45, + "hr_8": 0.45, + "hr_9": 0.45, + "hr_10": 0.45, + "hr_11": 0.45, + "hr_12": 0.45, + "hr_13": 0.45, + "hr_14": 0.45, + "hr_15": 0.45, + "hr_16": 0.45, + "hr_17": 0.45, + "hr_18": 0.45, + "hr_19": 0.45, + "hr_20": 0.45, + "hr_21": 0.45, + "hr_22": 0.45, + "hr_23": 0.45, + "hr_24": 0.45, + "annotation": null + }, + { + "name": "patient_room", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.45, + "hr_2": 0.45, + "hr_3": 0.45, + "hr_4": 0.45, + "hr_5": 0.45, + "hr_6": 0.45, + "hr_7": 0.45, + "hr_8": 0.45, + "hr_9": 0.45, + "hr_10": 0.45, + "hr_11": 0.45, + "hr_12": 0.45, + "hr_13": 0.45, + "hr_14": 0.45, + "hr_15": 0.45, + "hr_16": 0.45, + "hr_17": 0.45, + "hr_18": 0.45, + "hr_19": 0.45, + "hr_20": 0.45, + "hr_21": 0.45, + "hr_22": 0.45, + "hr_23": 0.45, + "hr_24": 0.45, + "annotation": null + }, + { + "name": "patient_room", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.15, + "hr_8": 0.8, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.8, + "hr_16": 0.6, + "hr_17": 0.6, + "hr_18": 0.8, + "hr_19": 0.9, + "hr_20": 0.45, + "hr_21": 0.45, + "hr_22": 0.45, + "hr_23": 0.35, + "hr_24": 0.15, + "annotation": null + }, + { + "name": "patient_room", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.15, + "hr_8": 0.35, + "hr_9": 0.45, + "hr_10": 0.45, + "hr_11": 0.45, + "hr_12": 0.45, + "hr_13": 0.45, + "hr_14": 0.45, + "hr_15": 0.35, + "hr_16": 0.15, + "hr_17": 0.15, + "hr_18": 0.35, + "hr_19": 0.45, + "hr_20": 0.45, + "hr_21": 0.45, + "hr_22": 0.45, + "hr_23": 0.35, + "hr_24": 0.15, + "annotation": null + }, + { + "name": "patient_room", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.15, + "hr_8": 0.35, + "hr_9": 0.45, + "hr_10": 0.45, + "hr_11": 0.45, + "hr_12": 0.45, + "hr_13": 0.45, + "hr_14": 0.45, + "hr_15": 0.35, + "hr_16": 0.15, + "hr_17": 0.15, + "hr_18": 0.35, + "hr_19": 0.45, + "hr_20": 0.45, + "hr_21": 0.45, + "hr_22": 0.45, + "hr_23": 0.35, + "hr_24": 0.15, + "annotation": null + }, + { + "name": "patient_room", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.475, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.475, + "hr_20": 0.475, + "hr_21": 0.475, + "hr_22": 0.475, + "hr_23": 0.475, + "hr_24": 0.195, + "annotation": null + }, + { + "name": "patient_room", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.475, + "hr_9": 0.475, + "hr_10": 0.475, + "hr_11": 0.475, + "hr_12": 0.475, + "hr_13": 0.475, + "hr_14": 0.475, + "hr_15": 0.475, + "hr_16": 0.475, + "hr_17": 0.475, + "hr_18": 0.475, + "hr_19": 0.475, + "hr_20": 0.475, + "hr_21": 0.475, + "hr_22": 0.475, + "hr_23": 0.475, + "hr_24": 0.195, + "annotation": null + }, + { + "name": "patient_room", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.475, + "hr_9": 0.475, + "hr_10": 0.475, + "hr_11": 0.475, + "hr_12": 0.475, + "hr_13": 0.475, + "hr_14": 0.475, + "hr_15": 0.475, + "hr_16": 0.475, + "hr_17": 0.475, + "hr_18": 0.475, + "hr_19": 0.475, + "hr_20": 0.475, + "hr_21": 0.475, + "hr_22": 0.475, + "hr_23": 0.475, + "hr_24": 0.195, + "annotation": null + }, + { + "name": "pharmacy", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "pharmacy", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "pharmacy", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "pharmacy", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "pharmacy", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "pharmacy", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "pharmacy", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "pharmacy", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.05, + "hr_11": 0.05, + "hr_12": 0.05, + "hr_13": 0.05, + "hr_14": 0.05, + "hr_15": 0.05, + "hr_16": 0.05, + "hr_17": 0.05, + "hr_18": 0.05, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "pharmacy", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.05, + "hr_11": 0.05, + "hr_12": 0.05, + "hr_13": 0.05, + "hr_14": 0.05, + "hr_15": 0.05, + "hr_16": 0.05, + "hr_17": 0.05, + "hr_18": 0.05, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "corridor_hospital", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "corridor_hospital", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "corridor_hospital", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "corridor_hospital", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "corridor_hospital", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "corridor_hospital", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "corridor_hospital", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "corridor_hospital", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "corridor_hospital", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "fellowship_hall_religious_facility", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.45, + "hr_9": 0.45, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "fellowship_hall_religious_facility", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.45, + "hr_9": 0.45, + "hr_10": 0.45, + "hr_11": 0.45, + "hr_12": 0.45, + "hr_13": 0.45, + "hr_14": 0.45, + "hr_15": 0.45, + "hr_16": 0.45, + "hr_17": 0.45, + "hr_18": 0.45, + "hr_19": 0.45, + "hr_20": 0.45, + "hr_21": 0.45, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "fellowship_hall_religious_facility", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.45, + "hr_9": 0.45, + "hr_10": 0.45, + "hr_11": 0.45, + "hr_12": 0.45, + "hr_13": 0.45, + "hr_14": 0.45, + "hr_15": 0.45, + "hr_16": 0.45, + "hr_17": 0.45, + "hr_18": 0.45, + "hr_19": 0.45, + "hr_20": 0.45, + "hr_21": 0.45, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "fellowship_hall_religious_facility", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.45, + "hr_9": 0.45, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "fellowship_hall_religious_facility", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.45, + "hr_9": 0.45, + "hr_10": 0.45, + "hr_11": 0.45, + "hr_12": 0.45, + "hr_13": 0.45, + "hr_14": 0.45, + "hr_15": 0.45, + "hr_16": 0.45, + "hr_17": 0.45, + "hr_18": 0.45, + "hr_19": 0.45, + "hr_20": 0.45, + "hr_21": 0.45, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "fellowship_hall_religious_facility", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.45, + "hr_9": 0.45, + "hr_10": 0.45, + "hr_11": 0.45, + "hr_12": 0.45, + "hr_13": 0.45, + "hr_14": 0.45, + "hr_15": 0.45, + "hr_16": 0.45, + "hr_17": 0.45, + "hr_18": 0.45, + "hr_19": 0.45, + "hr_20": 0.45, + "hr_21": 0.45, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "fellowship_hall_religious_facility", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.475, + "hr_9": 0.475, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "fellowship_hall_religious_facility", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.475, + "hr_9": 0.475, + "hr_10": 0.475, + "hr_11": 0.475, + "hr_12": 0.475, + "hr_13": 0.475, + "hr_14": 0.475, + "hr_15": 0.475, + "hr_16": 0.475, + "hr_17": 0.475, + "hr_18": 0.475, + "hr_19": 0.475, + "hr_20": 0.475, + "hr_21": 0.475, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "fellowship_hall_religious_facility", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.475, + "hr_9": 0.475, + "hr_10": 0.475, + "hr_11": 0.475, + "hr_12": 0.475, + "hr_13": 0.475, + "hr_14": 0.475, + "hr_15": 0.475, + "hr_16": 0.475, + "hr_17": 0.475, + "hr_18": 0.475, + "hr_19": 0.475, + "hr_20": 0.475, + "hr_21": 0.475, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "lounge_breakroom_healthcare_facility", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lounge_breakroom_healthcare_facility", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lounge_breakroom_healthcare_facility", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lounge_breakroom_healthcare_facility", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lounge_breakroom_healthcare_facility", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lounge_breakroom_healthcare_facility", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lounge_breakroom_healthcare_facility", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.76, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.76, + "hr_14": 0.76, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.76, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "lounge_breakroom_healthcare_facility", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.76, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.76, + "hr_14": 0.76, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.76, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "lounge_breakroom_healthcare_facility", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.76, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.76, + "hr_14": 0.76, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.76, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "operating_room", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "operating_room", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "operating_room", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "operating_room", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.18, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.58, + "hr_23": 0.45, + "hr_24": 0.18, + "annotation": null + }, + { + "name": "operating_room", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.18, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.58, + "hr_23": 0.45, + "hr_24": 0.18, + "annotation": null + }, + { + "name": "operating_room", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.18, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.58, + "hr_23": 0.45, + "hr_24": 0.18, + "annotation": null + }, + { + "name": "operating_room", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "operating_room", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "operating_room", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "physical_therapy", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "physical_therapy", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "physical_therapy", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "physical_therapy", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "physical_therapy", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "physical_therapy", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "physical_therapy", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.76, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.76, + "hr_14": 0.76, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.76, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "physical_therapy", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.76, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.76, + "hr_14": 0.76, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.76, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "physical_therapy", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.76, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.76, + "hr_14": 0.76, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.76, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "storage_50_to_1000_sf_hospital", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_50_to_1000_sf_hospital", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_50_to_1000_sf_hospital", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_50_to_1000_sf_hospital", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_50_to_1000_sf_hospital", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_50_to_1000_sf_hospital", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_50_to_1000_sf_hospital", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_50_to_1000_sf_hospital", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_50_to_1000_sf_hospital", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_lt_50_sf_hospital", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_lt_50_sf_hospital", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_lt_50_sf_hospital", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_lt_50_sf_hospital", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_lt_50_sf_hospital", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_lt_50_sf_hospital", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_lt_50_sf_hospital", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_lt_50_sf_hospital", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "storage_lt_50_sf_hospital", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "guest_room", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.25, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0.25, + "hr_23": 0.75, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "guest_room", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.25, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0.25, + "hr_23": 0.75, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "guest_room", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.25, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0.25, + "hr_23": 0.75, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "guest_room", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "guest_room", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "guest_room", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "guest_room", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.07, + "hr_2": 0.07, + "hr_3": 0.07, + "hr_4": 0.07, + "hr_5": 0.07, + "hr_6": 0.07, + "hr_7": 0.07, + "hr_8": 0.53, + "hr_9": 0.9, + "hr_10": 0.53, + "hr_11": 0.07, + "hr_12": 0.07, + "hr_13": 0.07, + "hr_14": 0.07, + "hr_15": 0.07, + "hr_16": 0.07, + "hr_17": 0.07, + "hr_18": 0.3, + "hr_19": 0.53, + "hr_20": 0.77, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.77, + "hr_24": 0.3, + "annotation": null + }, + { + "name": "guest_room", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.07, + "hr_2": 0.07, + "hr_3": 0.07, + "hr_4": 0.07, + "hr_5": 0.07, + "hr_6": 0.07, + "hr_7": 0.07, + "hr_8": 0.53, + "hr_9": 0.9, + "hr_10": 0.53, + "hr_11": 0.07, + "hr_12": 0.07, + "hr_13": 0.07, + "hr_14": 0.07, + "hr_15": 0.07, + "hr_16": 0.07, + "hr_17": 0.07, + "hr_18": 0.3, + "hr_19": 0.53, + "hr_20": 0.77, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.77, + "hr_24": 0.3, + "annotation": null + }, + { + "name": "guest_room", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.07, + "hr_2": 0.07, + "hr_3": 0.07, + "hr_4": 0.07, + "hr_5": 0.07, + "hr_6": 0.07, + "hr_7": 0.07, + "hr_8": 0.53, + "hr_9": 0.9, + "hr_10": 0.53, + "hr_11": 0.07, + "hr_12": 0.07, + "hr_13": 0.07, + "hr_14": 0.07, + "hr_15": 0.07, + "hr_16": 0.07, + "hr_17": 0.07, + "hr_18": 0.3, + "hr_19": 0.53, + "hr_20": 0.77, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.77, + "hr_24": 0.3, + "annotation": null + }, + { + "name": "lobby_hotel", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.3, + "annotation": null + }, + { + "name": "lobby_hotel", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.3, + "annotation": null + }, + { + "name": "lobby_hotel", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.3, + "annotation": null + }, + { + "name": "lobby_hotel", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "lobby_hotel", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "lobby_hotel", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "lobby_hotel", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "lobby_hotel", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "lobby_hotel", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "library_cataloging", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "library_cataloging", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "library_cataloging", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "library_cataloging", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "library_cataloging", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "library_cataloging", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "library_cataloging", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "library_cataloging", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "library_cataloging", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "museum_exhibit_area", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.375, + "hr_11": 0.45, + "hr_12": 0.45, + "hr_13": 0.375, + "hr_14": 0.375, + "hr_15": 0.45, + "hr_16": 0.45, + "hr_17": 0.7, + "hr_18": 0.5, + "hr_19": 0.125, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "museum_exhibit_area", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.375, + "hr_11": 0.45, + "hr_12": 0.45, + "hr_13": 0.375, + "hr_14": 0.375, + "hr_15": 0.45, + "hr_16": 0.45, + "hr_17": 0.7, + "hr_18": 0.5, + "hr_19": 0.125, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "museum_exhibit_area", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.375, + "hr_11": 0.45, + "hr_12": 0.45, + "hr_13": 0.375, + "hr_14": 0.375, + "hr_15": 0.45, + "hr_16": 0.45, + "hr_17": 0.7, + "hr_18": 0.5, + "hr_19": 0.125, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "museum_exhibit_area", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.45, + "hr_2": 0.45, + "hr_3": 0.45, + "hr_4": 0.45, + "hr_5": 0.45, + "hr_6": 0.45, + "hr_7": 0.45, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.45, + "annotation": null + }, + { + "name": "museum_exhibit_area", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.45, + "hr_2": 0.45, + "hr_3": 0.45, + "hr_4": 0.45, + "hr_5": 0.45, + "hr_6": 0.45, + "hr_7": 0.45, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.45, + "annotation": null + }, + { + "name": "museum_exhibit_area", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.45, + "hr_2": 0.45, + "hr_3": 0.45, + "hr_4": 0.45, + "hr_5": 0.45, + "hr_6": 0.45, + "hr_7": 0.45, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.45, + "annotation": null + }, + { + "name": "museum_exhibit_area", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.055, + "hr_20": 0.055, + "hr_21": 0.055, + "hr_22": 0.055, + "hr_23": 0.055, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "museum_exhibit_area", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.055, + "hr_20": 0.055, + "hr_21": 0.055, + "hr_22": 0.055, + "hr_23": 0.055, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "museum_exhibit_area", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.055, + "hr_20": 0.055, + "hr_21": 0.055, + "hr_22": 0.055, + "hr_23": 0.055, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "corridor_manufacturing_facility", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "corridor_manufacturing_facility", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "corridor_manufacturing_facility", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "corridor_manufacturing_facility", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "corridor_manufacturing_facility", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "corridor_manufacturing_facility", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "corridor_manufacturing_facility", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.04, + "hr_2": 0.04, + "hr_3": 0.04, + "hr_4": 0.04, + "hr_5": 0.04, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.04, + "hr_23": 0.04, + "hr_24": 0.04, + "annotation": null + }, + { + "name": "corridor_manufacturing_facility", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.04, + "hr_2": 0.04, + "hr_3": 0.04, + "hr_4": 0.04, + "hr_5": 0.04, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.04, + "hr_23": 0.04, + "hr_24": 0.04, + "annotation": null + }, + { + "name": "corridor_manufacturing_facility", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.04, + "hr_2": 0.04, + "hr_3": 0.04, + "hr_4": 0.04, + "hr_5": 0.04, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.04, + "hr_23": 0.04, + "hr_24": 0.04, + "annotation": null + }, + { + "name": "manufacturing_equipment_room", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "manufacturing_equipment_room", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "manufacturing_equipment_room", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "manufacturing_equipment_room", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "manufacturing_equipment_room", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "manufacturing_equipment_room", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "manufacturing_equipment_room", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "manufacturing_equipment_room", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "manufacturing_equipment_room", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "manufacturing_low_bay", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "manufacturing_low_bay", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "manufacturing_low_bay", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "manufacturing_low_bay", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "manufacturing_low_bay", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "manufacturing_low_bay", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "manufacturing_low_bay", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "manufacturing_low_bay", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "manufacturing_low_bay", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "performing_arts_dressing_room", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.25, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.825, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "performing_arts_dressing_room", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.25, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.45, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "performing_arts_dressing_room", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.25, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.45, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "performing_arts_dressing_room", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.45, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "performing_arts_dressing_room", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.45, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.45, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "performing_arts_dressing_room", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.45, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.45, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "performing_arts_dressing_room", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.045, + "hr_2": 0.045, + "hr_3": 0.045, + "hr_4": 0.045, + "hr_5": 0.055, + "hr_6": 0.055, + "hr_7": 0.055, + "hr_8": 0.055, + "hr_9": 0.48, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.475, + "hr_20": 0.475, + "hr_21": 0.475, + "hr_22": 0.045, + "hr_23": 0.045, + "hr_24": 0.045, + "annotation": null + }, + { + "name": "performing_arts_dressing_room", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.045, + "hr_2": 0.045, + "hr_3": 0.045, + "hr_4": 0.045, + "hr_5": 0.055, + "hr_6": 0.055, + "hr_7": 0.055, + "hr_8": 0.055, + "hr_9": 0.48, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.48, + "hr_19": 0.055, + "hr_20": 0.055, + "hr_21": 0.055, + "hr_22": 0.045, + "hr_23": 0.045, + "hr_24": 0.045, + "annotation": null + }, + { + "name": "performing_arts_dressing_room", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.045, + "hr_2": 0.045, + "hr_3": 0.045, + "hr_4": 0.045, + "hr_5": 0.045, + "hr_6": 0.045, + "hr_7": 0.045, + "hr_8": 0.045, + "hr_9": 0.05, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.48, + "hr_19": 0.055, + "hr_20": 0.055, + "hr_21": 0.055, + "hr_22": 0.045, + "hr_23": 0.045, + "hr_24": 0.045, + "annotation": null + }, + { + "name": "audience_seating_auditorium", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.67, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_auditorium", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.67, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_auditorium", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.67, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_auditorium", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_auditorium", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_auditorium", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_auditorium", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.06, + "hr_2": 0.06, + "hr_3": 0.06, + "hr_4": 0.06, + "hr_5": 0.06, + "hr_6": 0.06, + "hr_7": 0.06, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.06, + "hr_11": 0.06, + "hr_12": 0.06, + "hr_13": 0.06, + "hr_14": 0.06, + "hr_15": 0.06, + "hr_16": 0.06, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "audience_seating_auditorium", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.06, + "hr_2": 0.06, + "hr_3": 0.06, + "hr_4": 0.06, + "hr_5": 0.06, + "hr_6": 0.06, + "hr_7": 0.06, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.06, + "hr_11": 0.06, + "hr_12": 0.06, + "hr_13": 0.06, + "hr_14": 0.06, + "hr_15": 0.06, + "hr_16": 0.06, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "audience_seating_auditorium", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.06, + "hr_2": 0.06, + "hr_3": 0.06, + "hr_4": 0.06, + "hr_5": 0.06, + "hr_6": 0.06, + "hr_7": 0.06, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.06, + "hr_11": 0.06, + "hr_12": 0.06, + "hr_13": 0.06, + "hr_14": 0.06, + "hr_15": 0.06, + "hr_16": 0.06, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "audience_seating_motion_picture_theater", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.67, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_motion_picture_theater", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.67, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_motion_picture_theater", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.67, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_motion_picture_theater", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_motion_picture_theater", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_motion_picture_theater", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_motion_picture_theater", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.06, + "hr_2": 0.06, + "hr_3": 0.06, + "hr_4": 0.06, + "hr_5": 0.06, + "hr_6": 0.06, + "hr_7": 0.06, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.06, + "hr_11": 0.06, + "hr_12": 0.06, + "hr_13": 0.06, + "hr_14": 0.06, + "hr_15": 0.06, + "hr_16": 0.06, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "audience_seating_motion_picture_theater", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.06, + "hr_2": 0.06, + "hr_3": 0.06, + "hr_4": 0.06, + "hr_5": 0.06, + "hr_6": 0.06, + "hr_7": 0.06, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.06, + "hr_11": 0.06, + "hr_12": 0.06, + "hr_13": 0.06, + "hr_14": 0.06, + "hr_15": 0.06, + "hr_16": 0.06, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "audience_seating_motion_picture_theater", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.06, + "hr_2": 0.06, + "hr_3": 0.06, + "hr_4": 0.06, + "hr_5": 0.06, + "hr_6": 0.06, + "hr_7": 0.06, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.06, + "hr_11": 0.06, + "hr_12": 0.06, + "hr_13": 0.06, + "hr_14": 0.06, + "hr_15": 0.06, + "hr_16": 0.06, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "lobby_motion_picture_theater", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lobby_motion_picture_theater", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lobby_motion_picture_theater", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lobby_motion_picture_theater", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lobby_motion_picture_theater", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lobby_motion_picture_theater", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lobby_motion_picture_theater", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "lobby_motion_picture_theater", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "lobby_motion_picture_theater", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "dwelling_unit", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.5, + "hr_9": 0.25, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0.25, + "hr_24": 0.75, + "annotation": null + }, + { + "name": "dwelling_unit", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.5, + "hr_9": 0.25, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0.25, + "hr_24": 0.75, + "annotation": null + }, + { + "name": "dwelling_unit", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.5, + "hr_9": 0.25, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0.25, + "hr_24": 0.75, + "annotation": null + }, + { + "name": "dwelling_unit", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0.2, + "hr_21": 0.2, + "hr_22": 0.2, + "hr_23": 0.2, + "hr_24": 0, + "annotation": null + }, + { + "name": "dwelling_unit", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0.2, + "hr_21": 0.2, + "hr_22": 0.2, + "hr_23": 0.2, + "hr_24": 0, + "annotation": null + }, + { + "name": "dwelling_unit", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0.2, + "hr_21": 0.2, + "hr_22": 0.2, + "hr_23": 0.2, + "hr_24": 0, + "annotation": null + }, + { + "name": "dwelling_unit", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.07, + "hr_2": 0.07, + "hr_3": 0.07, + "hr_4": 0.07, + "hr_5": 0.07, + "hr_6": 0.07, + "hr_7": 0.07, + "hr_8": 0.53, + "hr_9": 0.9, + "hr_10": 0.53, + "hr_11": 0.07, + "hr_12": 0.07, + "hr_13": 0.07, + "hr_14": 0.07, + "hr_15": 0.07, + "hr_16": 0.07, + "hr_17": 0.07, + "hr_18": 0.3, + "hr_19": 0.53, + "hr_20": 0.77, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.77, + "hr_24": 0.3, + "annotation": null + }, + { + "name": "dwelling_unit", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.07, + "hr_2": 0.07, + "hr_3": 0.07, + "hr_4": 0.07, + "hr_5": 0.07, + "hr_6": 0.07, + "hr_7": 0.07, + "hr_8": 0.53, + "hr_9": 0.9, + "hr_10": 0.53, + "hr_11": 0.07, + "hr_12": 0.07, + "hr_13": 0.07, + "hr_14": 0.07, + "hr_15": 0.07, + "hr_16": 0.07, + "hr_17": 0.07, + "hr_18": 0.3, + "hr_19": 0.53, + "hr_20": 0.77, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.77, + "hr_24": 0.3, + "annotation": null + }, + { + "name": "dwelling_unit", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.07, + "hr_2": 0.07, + "hr_3": 0.07, + "hr_4": 0.07, + "hr_5": 0.07, + "hr_6": 0.07, + "hr_7": 0.07, + "hr_8": 0.53, + "hr_9": 0.9, + "hr_10": 0.53, + "hr_11": 0.07, + "hr_12": 0.07, + "hr_13": 0.07, + "hr_14": 0.07, + "hr_15": 0.07, + "hr_16": 0.07, + "hr_17": 0.07, + "hr_18": 0.3, + "hr_19": 0.53, + "hr_20": 0.77, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.77, + "hr_24": 0.3, + "annotation": null + }, + { + "name": "museum_restoration", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "museum_restoration", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "museum_restoration", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "museum_restoration", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "museum_restoration", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "museum_restoration", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "museum_restoration", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "museum_restoration", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "museum_restoration", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "banking_activity", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "banking_activity", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "banking_activity", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "banking_activity", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "banking_activity", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "banking_activity", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "banking_activity", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "banking_activity", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.05, + "hr_11": 0.05, + "hr_12": 0.05, + "hr_13": 0.05, + "hr_14": 0.05, + "hr_15": 0.05, + "hr_16": 0.05, + "hr_17": 0.05, + "hr_18": 0.05, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "banking_activity", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.05, + "hr_11": 0.05, + "hr_12": 0.05, + "hr_13": 0.05, + "hr_14": 0.05, + "hr_15": 0.05, + "hr_16": 0.05, + "hr_17": 0.05, + "hr_18": 0.05, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "warehouse_fine_storage", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.45, + "hr_10": 0.455, + "hr_11": 0.455, + "hr_12": 0.455, + "hr_13": 0.455, + "hr_14": 0.455, + "hr_15": 0.455, + "hr_16": 0.455, + "hr_17": 0.455, + "hr_18": 0.45, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "warehouse_fine_storage", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.45, + "hr_10": 0.455, + "hr_11": 0.455, + "hr_12": 0.455, + "hr_13": 0.455, + "hr_14": 0.455, + "hr_15": 0.455, + "hr_16": 0.455, + "hr_17": 0.455, + "hr_18": 0.45, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "warehouse_fine_storage", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.45, + "hr_10": 0.455, + "hr_11": 0.455, + "hr_12": 0.455, + "hr_13": 0.455, + "hr_14": 0.455, + "hr_15": 0.455, + "hr_16": 0.455, + "hr_17": 0.455, + "hr_18": 0.45, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "warehouse_fine_storage", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.45, + "hr_10": 0.455, + "hr_11": 0.455, + "hr_12": 0.455, + "hr_13": 0.455, + "hr_14": 0.455, + "hr_15": 0.455, + "hr_16": 0.455, + "hr_17": 0.455, + "hr_18": 0.45, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "warehouse_fine_storage", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.45, + "hr_10": 0.455, + "hr_11": 0.455, + "hr_12": 0.455, + "hr_13": 0.455, + "hr_14": 0.455, + "hr_15": 0.455, + "hr_16": 0.455, + "hr_17": 0.455, + "hr_18": 0.45, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "warehouse_fine_storage", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.45, + "hr_10": 0.455, + "hr_11": 0.455, + "hr_12": 0.455, + "hr_13": 0.455, + "hr_14": 0.455, + "hr_15": 0.455, + "hr_16": 0.455, + "hr_17": 0.455, + "hr_18": 0.45, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "warehouse_fine_storage", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "warehouse_fine_storage", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "warehouse_fine_storage", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "classroom_lecture_training_penitentiary", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.1, + "hr_9": 0.25, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.5, + "hr_14": 0.5, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "classroom_lecture_training_penitentiary", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "classroom_lecture_training_penitentiary", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "classroom_lecture_training_penitentiary", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "classroom_lecture_training_penitentiary", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "classroom_lecture_training_penitentiary", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "classroom_lecture_training_penitentiary", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.04, + "hr_2": 0.04, + "hr_3": 0.04, + "hr_4": 0.04, + "hr_5": 0.04, + "hr_6": 0.04, + "hr_7": 0.04, + "hr_8": 0.04, + "hr_9": 0.04, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.04, + "hr_19": 0.04, + "hr_20": 0.04, + "hr_21": 0.04, + "hr_22": 0.04, + "hr_23": 0.04, + "hr_24": 0.04, + "annotation": null + }, + { + "name": "classroom_lecture_training_penitentiary", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.04, + "hr_2": 0.04, + "hr_3": 0.04, + "hr_4": 0.04, + "hr_5": 0.04, + "hr_6": 0.04, + "hr_7": 0.04, + "hr_8": 0.04, + "hr_9": 0.04, + "hr_10": 0.04, + "hr_11": 0.04, + "hr_12": 0.04, + "hr_13": 0.04, + "hr_14": 0.04, + "hr_15": 0.04, + "hr_16": 0.04, + "hr_17": 0.04, + "hr_18": 0.04, + "hr_19": 0.04, + "hr_20": 0.04, + "hr_21": 0.04, + "hr_22": 0.04, + "hr_23": 0.04, + "hr_24": 0.04, + "annotation": null + }, + { + "name": "classroom_lecture_training_penitentiary", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.04, + "hr_2": 0.04, + "hr_3": 0.04, + "hr_4": 0.04, + "hr_5": 0.04, + "hr_6": 0.04, + "hr_7": 0.04, + "hr_8": 0.04, + "hr_9": 0.04, + "hr_10": 0.04, + "hr_11": 0.04, + "hr_12": 0.04, + "hr_13": 0.04, + "hr_14": 0.04, + "hr_15": 0.04, + "hr_16": 0.04, + "hr_17": 0.04, + "hr_18": 0.04, + "hr_19": 0.04, + "hr_20": 0.04, + "hr_21": 0.04, + "hr_22": 0.04, + "hr_23": 0.04, + "hr_24": 0.04, + "annotation": null + }, + { + "name": "dining_penitentiary", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0.25, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.25, + "hr_11": 0, + "hr_12": 0.25, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.5, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0.5, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.5, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_penitentiary", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0.25, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.25, + "hr_11": 0, + "hr_12": 0.25, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.5, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0.5, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.5, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_penitentiary", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0.25, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.25, + "hr_11": 0, + "hr_12": 0.25, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.5, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0.5, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.5, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_penitentiary", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_penitentiary", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_penitentiary", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "dining_penitentiary", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.07, + "hr_2": 0.07, + "hr_3": 0.07, + "hr_4": 0.07, + "hr_5": 0.07, + "hr_6": 0.07, + "hr_7": 0.3, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.3, + "hr_11": 0.07, + "hr_12": 0.3, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.54, + "hr_16": 0.07, + "hr_17": 0.07, + "hr_18": 0.54, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.54, + "hr_22": 0.07, + "hr_23": 0.07, + "hr_24": 0.07, + "annotation": null + }, + { + "name": "dining_penitentiary", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.07, + "hr_2": 0.07, + "hr_3": 0.07, + "hr_4": 0.07, + "hr_5": 0.07, + "hr_6": 0.07, + "hr_7": 0.3, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.3, + "hr_11": 0.07, + "hr_12": 0.3, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.54, + "hr_16": 0.07, + "hr_17": 0.07, + "hr_18": 0.54, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.54, + "hr_22": 0.07, + "hr_23": 0.07, + "hr_24": 0.07, + "annotation": null + }, + { + "name": "dining_penitentiary", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.07, + "hr_2": 0.07, + "hr_3": 0.07, + "hr_4": 0.07, + "hr_5": 0.07, + "hr_6": 0.07, + "hr_7": 0.3, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.3, + "hr_11": 0.07, + "hr_12": 0.3, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.54, + "hr_16": 0.07, + "hr_17": 0.07, + "hr_18": 0.54, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.54, + "hr_22": 0.07, + "hr_23": 0.07, + "hr_24": 0.07, + "annotation": null + }, + { + "name": "audience_seating_performing_arts_theater", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.67, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_performing_arts_theater", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.67, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_performing_arts_theater", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.67, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_performing_arts_theater", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_performing_arts_theater", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_performing_arts_theater", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_performing_arts_theater", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.06, + "hr_2": 0.06, + "hr_3": 0.06, + "hr_4": 0.06, + "hr_5": 0.06, + "hr_6": 0.06, + "hr_7": 0.06, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.06, + "hr_11": 0.06, + "hr_12": 0.06, + "hr_13": 0.06, + "hr_14": 0.06, + "hr_15": 0.06, + "hr_16": 0.06, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "audience_seating_performing_arts_theater", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.06, + "hr_2": 0.06, + "hr_3": 0.06, + "hr_4": 0.06, + "hr_5": 0.06, + "hr_6": 0.06, + "hr_7": 0.06, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.06, + "hr_11": 0.06, + "hr_12": 0.06, + "hr_13": 0.06, + "hr_14": 0.06, + "hr_15": 0.06, + "hr_16": 0.06, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "audience_seating_performing_arts_theater", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.06, + "hr_2": 0.06, + "hr_3": 0.06, + "hr_4": 0.06, + "hr_5": 0.06, + "hr_6": 0.06, + "hr_7": 0.06, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.06, + "hr_11": 0.06, + "hr_12": 0.06, + "hr_13": 0.06, + "hr_14": 0.06, + "hr_15": 0.06, + "hr_16": 0.06, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "lobby_performing_arts_theater", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lobby_performing_arts_theater", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lobby_performing_arts_theater", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.75, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lobby_performing_arts_theater", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lobby_performing_arts_theater", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lobby_performing_arts_theater", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "lobby_performing_arts_theater", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "lobby_performing_arts_theater", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "lobby_performing_arts_theater", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "audience_seating_religious_facility", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_religious_facility", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_religious_facility", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_religious_facility", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_religious_facility", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_religious_facility", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_religious_facility", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "audience_seating_religious_facility", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.05, + "hr_11": 0.05, + "hr_12": 0.05, + "hr_13": 0.05, + "hr_14": 0.05, + "hr_15": 0.05, + "hr_16": 0.05, + "hr_17": 0.05, + "hr_18": 0.05, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "audience_seating_religious_facility", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.05, + "hr_11": 0.05, + "hr_12": 0.05, + "hr_13": 0.05, + "hr_14": 0.05, + "hr_15": 0.05, + "hr_16": 0.05, + "hr_17": 0.05, + "hr_18": 0.05, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "worship_pulpit_choir_area", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "worship_pulpit_choir_area", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "worship_pulpit_choir_area", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "worship_pulpit_choir_area", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "worship_pulpit_choir_area", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "worship_pulpit_choir_area", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "worship_pulpit_choir_area", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "worship_pulpit_choir_area", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.05, + "hr_11": 0.05, + "hr_12": 0.05, + "hr_13": 0.05, + "hr_14": 0.05, + "hr_15": 0.05, + "hr_16": 0.05, + "hr_17": 0.05, + "hr_18": 0.05, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "worship_pulpit_choir_area", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.05, + "hr_11": 0.05, + "hr_12": 0.05, + "hr_13": 0.05, + "hr_14": 0.05, + "hr_15": 0.05, + "hr_16": 0.05, + "hr_17": 0.05, + "hr_18": 0.05, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "classroom_lecture_training_preschool_to_12th", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.1, + "hr_9": 0.25, + "hr_10": 0.75, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.5, + "hr_14": 0.5, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "classroom_lecture_training_preschool_to_12th", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "classroom_lecture_training_preschool_to_12th", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "classroom_lecture_training_preschool_to_12th", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "classroom_lecture_training_preschool_to_12th", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "classroom_lecture_training_preschool_to_12th", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "classroom_lecture_training_preschool_to_12th", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "classroom_lecture_training_preschool_to_12th", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.05, + "hr_11": 0.05, + "hr_12": 0.05, + "hr_13": 0.05, + "hr_14": 0.05, + "hr_15": 0.05, + "hr_16": 0.05, + "hr_17": 0.05, + "hr_18": 0.05, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "classroom_lecture_training_preschool_to_12th", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.05, + "hr_11": 0.05, + "hr_12": 0.05, + "hr_13": 0.05, + "hr_14": 0.05, + "hr_15": 0.05, + "hr_16": 0.05, + "hr_17": 0.05, + "hr_18": 0.05, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "sports_arena_playing_area_class_ii", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.125, + "hr_9": 0.25, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.825, + "hr_14": 0.825, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.7, + "hr_19": 0.575, + "hr_20": 0.45, + "hr_21": 0.45, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "sports_arena_playing_area_class_ii", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.825, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.825, + "hr_14": 0.825, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.825, + "hr_19": 0.45, + "hr_20": 0.45, + "hr_21": 0.45, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "sports_arena_playing_area_class_ii", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.825, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.825, + "hr_14": 0.825, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.825, + "hr_19": 0.45, + "hr_20": 0.45, + "hr_21": 0.45, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "sports_arena_playing_area_class_ii", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.45, + "hr_9": 0.45, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.45, + "hr_21": 0.45, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "sports_arena_playing_area_class_ii", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.45, + "hr_20": 0.45, + "hr_21": 0.45, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "sports_arena_playing_area_class_ii", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.45, + "hr_20": 0.45, + "hr_21": 0.45, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "sports_arena_playing_area_class_ii", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.475, + "hr_9": 0.475, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.475, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "sports_arena_playing_area_class_ii", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.83, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.83, + "hr_14": 0.83, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.83, + "hr_19": 0.475, + "hr_20": 0.475, + "hr_21": 0.475, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "sports_arena_playing_area_class_ii", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.05, + "hr_10": 0.83, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.83, + "hr_14": 0.83, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.83, + "hr_19": 0.475, + "hr_20": 0.475, + "hr_21": 0.475, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "audience_seating_sports_arena", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.67, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_sports_arena", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.67, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_sports_arena", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.5, + "hr_18": 0.5, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.67, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_sports_arena", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_sports_arena", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_sports_arena", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0, + "annotation": null + }, + { + "name": "audience_seating_sports_arena", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.06, + "hr_2": 0.06, + "hr_3": 0.06, + "hr_4": 0.06, + "hr_5": 0.06, + "hr_6": 0.06, + "hr_7": 0.06, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.06, + "hr_11": 0.06, + "hr_12": 0.06, + "hr_13": 0.06, + "hr_14": 0.06, + "hr_15": 0.06, + "hr_16": 0.06, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "audience_seating_sports_arena", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.06, + "hr_2": 0.06, + "hr_3": 0.06, + "hr_4": 0.06, + "hr_5": 0.06, + "hr_6": 0.06, + "hr_7": 0.06, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.06, + "hr_11": 0.06, + "hr_12": 0.06, + "hr_13": 0.06, + "hr_14": 0.06, + "hr_15": 0.06, + "hr_16": 0.06, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "audience_seating_sports_arena", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.06, + "hr_2": 0.06, + "hr_3": 0.06, + "hr_4": 0.06, + "hr_5": 0.06, + "hr_6": 0.06, + "hr_7": 0.06, + "hr_8": 0.06, + "hr_9": 0.06, + "hr_10": 0.06, + "hr_11": 0.06, + "hr_12": 0.06, + "hr_13": 0.06, + "hr_14": 0.06, + "hr_15": 0.06, + "hr_16": 0.06, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.34, + "annotation": null + }, + { + "name": "airport_concourse", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.25, + "hr_2": 0.25, + "hr_3": 0.25, + "hr_4": 0.25, + "hr_5": 0.25, + "hr_6": 0.25, + "hr_7": 0.25, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0.25, + "hr_21": 0.25, + "hr_22": 0.25, + "hr_23": 0.25, + "hr_24": 0.25, + "annotation": null + }, + { + "name": "airport_concourse", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.25, + "hr_2": 0.25, + "hr_3": 0.25, + "hr_4": 0.25, + "hr_5": 0.25, + "hr_6": 0.25, + "hr_7": 0.25, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0.25, + "hr_21": 0.25, + "hr_22": 0.25, + "hr_23": 0.25, + "hr_24": 0.25, + "annotation": null + }, + { + "name": "airport_concourse", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.25, + "hr_2": 0.25, + "hr_3": 0.25, + "hr_4": 0.25, + "hr_5": 0.25, + "hr_6": 0.25, + "hr_7": 0.25, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0.25, + "hr_21": 0.25, + "hr_22": 0.25, + "hr_23": 0.25, + "hr_24": 0.25, + "annotation": null + }, + { + "name": "airport_concourse", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "airport_concourse", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "airport_concourse", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "airport_concourse", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "airport_concourse", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "airport_concourse", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "atrium_lt_20_ft_height", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "atrium_lt_20_ft_height", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "atrium_lt_20_ft_height", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "atrium_lt_20_ft_height", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "atrium_lt_20_ft_height", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "atrium_lt_20_ft_height", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "atrium_lt_20_ft_height", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "atrium_lt_20_ft_height", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "atrium_lt_20_ft_height", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "atrium_gt_40_ft_height", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "atrium_gt_40_ft_height", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "atrium_gt_40_ft_height", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "atrium_gt_40_ft_height", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "atrium_gt_40_ft_height", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "atrium_gt_40_ft_height", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "atrium_gt_40_ft_height", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "atrium_gt_40_ft_height", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "atrium_gt_40_ft_height", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "atrium_gte_20_ft_and_lte_40_ft_in_height", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "atrium_gte_20_ft_and_lte_40_ft_in_height", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "atrium_gte_20_ft_and_lte_40_ft_in_height", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "atrium_gte_20_ft_and_lte_40_ft_in_height", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "atrium_gte_20_ft_and_lte_40_ft_in_height", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "atrium_gte_20_ft_and_lte_40_ft_in_height", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "atrium_gte_20_ft_and_lte_40_ft_in_height", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "atrium_gte_20_ft_and_lte_40_ft_in_height", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "atrium_gte_20_ft_and_lte_40_ft_in_height", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.05, + "hr_2": 0.05, + "hr_3": 0.05, + "hr_4": 0.05, + "hr_5": 0.05, + "hr_6": 0.05, + "hr_7": 0.05, + "hr_8": 0.05, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.05, + "hr_20": 0.05, + "hr_21": 0.05, + "hr_22": 0.05, + "hr_23": 0.05, + "hr_24": 0.05, + "annotation": null + }, + { + "name": "baggage_carousel", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.25, + "hr_2": 0.25, + "hr_3": 0.25, + "hr_4": 0.25, + "hr_5": 0.25, + "hr_6": 0.25, + "hr_7": 0.25, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0.25, + "hr_21": 0.25, + "hr_22": 0.25, + "hr_23": 0.25, + "hr_24": 0.25, + "annotation": null + }, + { + "name": "baggage_carousel", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.25, + "hr_2": 0.25, + "hr_3": 0.25, + "hr_4": 0.25, + "hr_5": 0.25, + "hr_6": 0.25, + "hr_7": 0.25, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0.25, + "hr_21": 0.25, + "hr_22": 0.25, + "hr_23": 0.25, + "hr_24": 0.25, + "annotation": null + }, + { + "name": "baggage_carousel", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.25, + "hr_2": 0.25, + "hr_3": 0.25, + "hr_4": 0.25, + "hr_5": 0.25, + "hr_6": 0.25, + "hr_7": 0.25, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0.25, + "hr_21": 0.25, + "hr_22": 0.25, + "hr_23": 0.25, + "hr_24": 0.25, + "annotation": null + }, + { + "name": "baggage_carousel", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "baggage_carousel", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "baggage_carousel", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "baggage_carousel", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "baggage_carousel", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "baggage_carousel", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "seating_area_general", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.25, + "hr_2": 0.25, + "hr_3": 0.25, + "hr_4": 0.25, + "hr_5": 0.25, + "hr_6": 0.25, + "hr_7": 0.25, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.25, + "hr_22": 0.25, + "hr_23": 0.25, + "hr_24": 0.25, + "annotation": null + }, + { + "name": "seating_area_general", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.25, + "hr_2": 0.25, + "hr_3": 0.25, + "hr_4": 0.25, + "hr_5": 0.25, + "hr_6": 0.25, + "hr_7": 0.25, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.25, + "hr_22": 0.25, + "hr_23": 0.25, + "hr_24": 0.25, + "annotation": null + }, + { + "name": "seating_area_general", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.25, + "hr_2": 0.25, + "hr_3": 0.25, + "hr_4": 0.25, + "hr_5": 0.25, + "hr_6": 0.25, + "hr_7": 0.25, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.25, + "hr_22": 0.25, + "hr_23": 0.25, + "hr_24": 0.25, + "annotation": null + }, + { + "name": "seating_area_general", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "seating_area_general", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "seating_area_general", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "seating_area_general", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "seating_area_general", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "seating_area_general", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.9, + "hr_2": 0.9, + "hr_3": 0.9, + "hr_4": 0.9, + "hr_5": 0.9, + "hr_6": 0.9, + "hr_7": 0.9, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.9, + "hr_21": 0.9, + "hr_22": 0.9, + "hr_23": 0.9, + "hr_24": 0.9, + "annotation": null + }, + { + "name": "transportation_ticket_counter", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "transportation_ticket_counter", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "transportation_ticket_counter", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.25, + "hr_9": 0.5, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.75, + "hr_14": 0.75, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.5, + "hr_19": 0.25, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "transportation_ticket_counter", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "transportation_ticket_counter", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "transportation_ticket_counter", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "transportation_ticket_counter", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.25, + "hr_2": 0.25, + "hr_3": 0.25, + "hr_4": 0.25, + "hr_5": 0.25, + "hr_6": 0.25, + "hr_7": 0.25, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.25, + "hr_21": 0.25, + "hr_22": 0.25, + "hr_23": 0.25, + "hr_24": 0.25, + "annotation": null + }, + { + "name": "transportation_ticket_counter", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.25, + "hr_2": 0.25, + "hr_3": 0.25, + "hr_4": 0.25, + "hr_5": 0.25, + "hr_6": 0.25, + "hr_7": 0.25, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.25, + "hr_21": 0.25, + "hr_22": 0.25, + "hr_23": 0.25, + "hr_24": 0.25, + "annotation": null + }, + { + "name": "transportation_ticket_counter", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0.25, + "hr_2": 0.25, + "hr_3": 0.25, + "hr_4": 0.25, + "hr_5": 0.25, + "hr_6": 0.25, + "hr_7": 0.25, + "hr_8": 0.9, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0.9, + "hr_20": 0.25, + "hr_21": 0.25, + "hr_22": 0.25, + "hr_23": 0.25, + "hr_24": 0.25, + "annotation": null + }, + { + "name": "warehouse_bulk_storage", + "category": "Occupancy", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "warehouse_bulk_storage", + "category": "Occupancy", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "warehouse_bulk_storage", + "category": "Occupancy", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "warehouse_bulk_storage", + "category": "Lighting", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "warehouse_bulk_storage", + "category": "Lighting", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "warehouse_bulk_storage", + "category": "Lighting", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0.9, + "hr_10": 0.9, + "hr_11": 0.9, + "hr_12": 0.9, + "hr_13": 0.9, + "hr_14": 0.9, + "hr_15": 0.9, + "hr_16": 0.9, + "hr_17": 0.9, + "hr_18": 0.9, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "warehouse_bulk_storage", + "category": "Equipment", + "units": null, + "day_types": "Default|SmrDsn|Wkdy", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "warehouse_bulk_storage", + "category": "Equipment", + "units": null, + "day_types": "Sat", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + }, + { + "name": "warehouse_bulk_storage", + "category": "Equipment", + "units": null, + "day_types": "WntrDsn|Hol|Sun", + "start_date": "1-Jan", + "end_date": "31-Dec", + "type": "Hourly", + "hr_1": 0, + "hr_2": 0, + "hr_3": 0, + "hr_4": 0, + "hr_5": 0, + "hr_6": 0, + "hr_7": 0, + "hr_8": 0, + "hr_9": 0, + "hr_10": 0, + "hr_11": 0, + "hr_12": 0, + "hr_13": 0, + "hr_14": 0, + "hr_15": 0, + "hr_16": 0, + "hr_17": 0, + "hr_18": 0, + "hr_19": 0, + "hr_20": 0, + "hr_21": 0, + "hr_22": 0, + "hr_23": 0, + "hr_24": 0, + "annotation": null + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/support_ventilation_space_type_name_tags.csv b/data/openstudio_standards_data/database_files/support_ventilation_space_type_name_tags.csv index 071f84481d..f8145aba7f 100644 --- a/data/openstudio_standards_data/database_files/support_ventilation_space_type_name_tags.csv +++ b/data/openstudio_standards_data/database_files/support_ventilation_space_type_name_tags.csv @@ -1,111 +1,99 @@ ventilation_space_type_name -correctional_facilities_cell -correctional_facilities_dayroom -correctional_facilities_guard_stations -correctional_facilities_booking_waiting -educational_facilities_daycare -educational_facilities_classroom_young -educational_facilities_classroom_old -educational_facilities_lecture_classroom -educational_facilities_lecture_hall -educational_facilities_art_classroom -educational_facilities_science_laboratories -educational_facilities_wood_metal_shop -educational_facilities_computer_lab -educational_facilities_media_center -educational_facilities_music_theater_dance -educational_facilities_multiuse_assembly -educational_facilities_daycare_sickroom -educational_facilities_libraries -educational_facilities_university_college_laboratories -food_beverage_service_restaurant_dining_rooms -food_beverage_service_cafeteria_fast_food_dining -food_beverage_service_bars_cocktail_lounges -food_beverage_service_kitchen -general_conference_meeting -general_conference_corridors -general_conference_storage_rooms -general_break_rooms -general_coffee_stations -hotels_motels_resorts_dormitories_bedroom_living_room -hotels_motels_resorts_dormitories_barracks_sleeping_areas -hotels_motels_resorts_dormitories_lobbies_prefunction -hotels_motels_resorts_dormitories_multi_purpose_assembly -hotels_motels_resorts_dormitories_laundry_rooms -hotels_motels_resorts_dormitories_laundry_rooms_w_dwelling_units -office_buildings_office_space -office_buildings_reception_areas -office_buildings_telephone_data_entry -office_buildings_main_entry_lobbies -office_buildings_breakrooms -office_buildings_occupiable_storage_rooms -miscellaneous_spaces_bank_ vaults_safe_deposit -miscellaneous_spaces_computer -miscellaneous_spaces_pharmacy -miscellaneous_spaces_photo_studios -miscellaneous_spaces_shipping_receiving -miscellaneous_spaces_transportation_waiting -miscellaneous_spaces_warehouses -miscellaneous_spaces_banks_bank_lobbies -miscellaneous_spaces_freezer_refrigerated_spaces -miscellaneous_spaces_manufacturing_wo_hazardous_materials -miscellaneous_spaces_manufacturing_w_hazardous_materials -miscellaneous_spaces_sorting_packing_light_assembly -miscellaneous_spaces_telephone_closets -public_assembly_spaces_auditorium_seating_area -public_assembly_spaces_religious_workshop -public_assembly_spaces_courtrooms -public_assembly_spaces_legislative_chambers -public_assembly_spaces_libraries -public_assembly_spaces_lobbies -public_assembly_spaces_children_museums -public_assembly_spaces_museums_galleries -retail_sales -retail_mall_common_areas -retail_barbershop -retail_beauty_nail_salons -retail_pet_shops -retail_supermarket -retail_coin_operated_laundries -sports_entertainment_sports_arena -sports_entertainment_gym_stadium -sports_entertainment_spectator_areas -sports_entertainment_swimming -sports_entertainment_disco_dance_floors -sports_entertainment_health_club_aerobics_room -sports_entertainment_health_club_weight_rooms -sports_entertainment_bowling_alley -sports_entertainment_gambling_casinos -sports_entertainment_game_arcades -sports_entertainment_stages_studios -animal_facilities_animal_exam_room -animal_facilities_animal_imaging -animal_facilities_animal_operating_rooms -animal_facilities_animal_postoperative_recovery_room -animal_facilities_animal_preparation_rooms -animal_facilities_animal_procedure_room -animal_facilities_animal_surgery_scrub -animal_facilities_large_animal_holding_room -animal_facilities_necropsy -animal_facilities_small_animal_cage_room_static -animal_facilities_small_animal_cage_room_ventilated -outpatient_health_care_facilities_birthing_room -outpatient_health_care_facilities_class_1_imaging_rooms -outpatient_health_care_facilities_dental_operatory -outpatient_health_care_facilities_general_examination_room -outpatient_health_care_facilities_other_dental_treatment_areas -outpatient_health_care_facilities_physical_therapy_exercise_area -outpatient_health_care_facilities_physical_therapy_individual_room -outpatient_health_care_facilities_physical_therapeutic_pool_area -outpatient_health_care_facilities_prosthetics_orthotics_room -outpatient_health_care_facilities_psychiatric_consultation_room -outpatient_health_care_facilities_psychiatric_examination_room -outpatient_health_care_facilities_psychiatric_group_room -outpatient_health_care_facilities_psychiatric_seclusion_room -outpatient_health_care_facilities_speech_therapy_room -outpatient_health_care_facilities_urgent_care_examination_room -outpatient_health_care_facilities_urgent_care_observation_room -outpatient_health_care_facilities_urgent_care_treatment_room -outpatient_health_care_facilities_urgent_care_triage_room -transient_residential_common_corridors -transient_residential_dwelling_unit +airport_concourse_ventilation +atrium_ventilation +attic_ventilation +audience_seating_ventilation +baggage_carousel_ventilation +banking_ventilation +classroom_lecture_training_ventilation +computer_room_ventilation +conference_meeting_multipurpose_ventilation +confinement_cells_ventilation +copy_print_ventilation +corridor_ventilation +courtroom_ventilation +datacenterhighite_ventilation +datacenterlowite_ventilation +dining_ventilation +dressing_room_ventilation +electrical_mechanical_ventilation +emergency_room_ventilation +exam_treatment_ventilation +exercise_area_ventilation +exhibit_ventilation +guest_room_ventilation +imaging_ventilation +judges_chambers_ventilation +food_preparation_ventilation +laboratory_ventilation +laundry_washing_ventilation +library_ventilation +living_quarters_ventilation +loading_dock_ventilation +lobby_ventilation +locker_room_ventilation +lounge_breakroom_ventilation +manufacturing_ventilation +medical_supply_ventilation +multifamily_ventilation +nursery_ventilation +nurses_station_ventilation +office_ventilation +office_enclosed_ventilation +operating_room_ventilation +patient_room_ventilation +pharmacy_ventilation +physical_therapy_ventilation +playing_area_ventilation +plenum_ventilation +post_office_ventilation +recovery_ventilation +recreation_common_living_ventilation +retail_sales_ventilation +shaft_ventilation +sleeping_quarters_ventilation +sports_arena_ventilation +stairwell_ventilation +storage_ventilation +transportation_ventilation +workshop_ventilation +worship_ventilation +correctional_facilities_booking_waiting_ventilation +correctional_facilities_day_room_ventilation +correctional_facilities_guard_stations_ventilation +educational_facilities_art_classroom_ventilation +educational_facilities_classrooms_ages_5-8_ventilation +educational_facilities_daycare_through_age_4_ventilation +educational_facilities_lecture_classroom_ventilation +educational_facilities_lecture_hall_fixed_seats_ventilation +educational_facilities_media_center_ventilation +educational_facilities_multi-use_assembly_ventilation +educational_facilities_music_theater_dance_ventilation +educational_facilities_science_laboratories_ventilation +educational_facilities_wood_metal_shop_ventilation +food_and_beverage_service_bars_cocktail_lounges_ventilation +food_and_beverage_service_cafeteria_fast_food_dining_ventilation +hotels_motels_resorts_dormitories_lobbies_prefunction_ventilation +miscellaneous_spaces_bank_vaults_safe_deposit_ventilation +miscellaneous_spaces_computer_not_printing_ventilation +miscellaneous_spaces_photo_studios_ventilation +miscellaneous_spaces_warehouses_ventilation +public_assembly_spaces_lobbies_ventilation +public_assembly_spaces_museums_childrens_ventilation +retail_barber_shop_ventilation +retail_beauty_and_nail_salons_ventilation +retail_coin-operated_laundries_ventilation +retail_pet_shops_animal_areas_ventilation +retail_supermarket_ventilation +sports_and_entertainment_bowling_alley_seating_ventilation +sports_and_entertainment_disco_dance_floors_ventilation +sports_and_entertainment_gambling_casinos_ventilation +sports_and_entertainment_game_arcades_ventilation +sports_and_entertainment_health_club_weight_rooms_ventilation +sports_and_entertainment_spectator_areas_ventilation +sports_and_entertainment_stages_studios_ventilation +sports_and_entertainment_swimming_pool_deck_ventilation +emergency_vehicle_garage_ventilation +interior_parking_ventilation +restroom_ventilation +vehicular_maintenance_ventilation diff --git a/data/openstudio_standards_data/database_files/support_ventilation_space_type_name_tags.json b/data/openstudio_standards_data/database_files/support_ventilation_space_type_name_tags.json index 702476a7e5..a3c784fa07 100644 --- a/data/openstudio_standards_data/database_files/support_ventilation_space_type_name_tags.json +++ b/data/openstudio_standards_data/database_files/support_ventilation_space_type_name_tags.json @@ -1,332 +1,296 @@ [ { - "ventilation_space_type_name": "correctional_facilities_cell" + "ventilation_space_type_name": "airport_concourse_ventilation" }, { - "ventilation_space_type_name": "correctional_facilities_dayroom" + "ventilation_space_type_name": "atrium_ventilation" }, { - "ventilation_space_type_name": "correctional_facilities_guard_stations" + "ventilation_space_type_name": "attic_ventilation" }, { - "ventilation_space_type_name": "correctional_facilities_booking_waiting" + "ventilation_space_type_name": "audience_seating_ventilation" }, { - "ventilation_space_type_name": "educational_facilities_daycare" + "ventilation_space_type_name": "baggage_carousel_ventilation" }, { - "ventilation_space_type_name": "educational_facilities_classroom_young" + "ventilation_space_type_name": "banking_ventilation" }, { - "ventilation_space_type_name": "educational_facilities_classroom_old" + "ventilation_space_type_name": "classroom_lecture_training_ventilation" }, { - "ventilation_space_type_name": "educational_facilities_lecture_classroom" + "ventilation_space_type_name": "computer_room_ventilation" }, { - "ventilation_space_type_name": "educational_facilities_lecture_hall" + "ventilation_space_type_name": "conference_meeting_multipurpose_ventilation" }, { - "ventilation_space_type_name": "educational_facilities_art_classroom" + "ventilation_space_type_name": "confinement_cells_ventilation" }, { - "ventilation_space_type_name": "educational_facilities_science_laboratories" + "ventilation_space_type_name": "copy_print_ventilation" }, { - "ventilation_space_type_name": "educational_facilities_wood_metal_shop" + "ventilation_space_type_name": "corridor_ventilation" }, { - "ventilation_space_type_name": "educational_facilities_computer_lab" + "ventilation_space_type_name": "courtroom_ventilation" }, { - "ventilation_space_type_name": "educational_facilities_media_center" + "ventilation_space_type_name": "datacenterhighite_ventilation" }, { - "ventilation_space_type_name": "educational_facilities_music_theater_dance" + "ventilation_space_type_name": "datacenterlowite_ventilation" }, { - "ventilation_space_type_name": "educational_facilities_multiuse_assembly" + "ventilation_space_type_name": "dining_ventilation" }, { - "ventilation_space_type_name": "educational_facilities_daycare_sickroom" + "ventilation_space_type_name": "dressing_room_ventilation" }, { - "ventilation_space_type_name": "educational_facilities_libraries" + "ventilation_space_type_name": "electrical_mechanical_ventilation" }, { - "ventilation_space_type_name": "educational_facilities_university_college_laboratories" + "ventilation_space_type_name": "emergency_room_ventilation" }, { - "ventilation_space_type_name": "food_beverage_service_restaurant_dining_rooms" + "ventilation_space_type_name": "exam_treatment_ventilation" }, { - "ventilation_space_type_name": "food_beverage_service_cafeteria_fast_food_dining" + "ventilation_space_type_name": "exercise_area_ventilation" }, { - "ventilation_space_type_name": "food_beverage_service_bars_cocktail_lounges" + "ventilation_space_type_name": "exhibit_ventilation" }, { - "ventilation_space_type_name": "food_beverage_service_kitchen" + "ventilation_space_type_name": "guest_room_ventilation" }, { - "ventilation_space_type_name": "general_conference_meeting" + "ventilation_space_type_name": "imaging_ventilation" }, { - "ventilation_space_type_name": "general_conference_corridors" + "ventilation_space_type_name": "judges_chambers_ventilation" }, { - "ventilation_space_type_name": "general_conference_storage_rooms" + "ventilation_space_type_name": "food_preparation_ventilation" }, { - "ventilation_space_type_name": "general_break_rooms" + "ventilation_space_type_name": "laboratory_ventilation" }, { - "ventilation_space_type_name": "general_coffee_stations" + "ventilation_space_type_name": "laundry_washing_ventilation" }, { - "ventilation_space_type_name": "hotels_motels_resorts_dormitories_bedroom_living_room" + "ventilation_space_type_name": "library_ventilation" }, { - "ventilation_space_type_name": "hotels_motels_resorts_dormitories_barracks_sleeping_areas" + "ventilation_space_type_name": "living_quarters_ventilation" }, { - "ventilation_space_type_name": "hotels_motels_resorts_dormitories_lobbies_prefunction" + "ventilation_space_type_name": "loading_dock_ventilation" }, { - "ventilation_space_type_name": "hotels_motels_resorts_dormitories_multi_purpose_assembly" + "ventilation_space_type_name": "lobby_ventilation" }, { - "ventilation_space_type_name": "hotels_motels_resorts_dormitories_laundry_rooms" + "ventilation_space_type_name": "locker_room_ventilation" }, { - "ventilation_space_type_name": "hotels_motels_resorts_dormitories_laundry_rooms_w_dwelling_units" + "ventilation_space_type_name": "lounge_breakroom_ventilation" }, { - "ventilation_space_type_name": "office_buildings_office_space" + "ventilation_space_type_name": "manufacturing_ventilation" }, { - "ventilation_space_type_name": "office_buildings_reception_areas" + "ventilation_space_type_name": "medical_supply_ventilation" }, { - "ventilation_space_type_name": "office_buildings_telephone_data_entry" + "ventilation_space_type_name": "multifamily_ventilation" }, { - "ventilation_space_type_name": "office_buildings_main_entry_lobbies" + "ventilation_space_type_name": "nursery_ventilation" }, { - "ventilation_space_type_name": "office_buildings_breakrooms" + "ventilation_space_type_name": "nurses_station_ventilation" }, { - "ventilation_space_type_name": "office_buildings_occupiable_storage_rooms" + "ventilation_space_type_name": "office_ventilation" }, { - "ventilation_space_type_name": "miscellaneous_spaces_bank_ vaults_safe_deposit" + "ventilation_space_type_name": "office_enclosed_ventilation" }, { - "ventilation_space_type_name": "miscellaneous_spaces_computer" + "ventilation_space_type_name": "operating_room_ventilation" }, { - "ventilation_space_type_name": "miscellaneous_spaces_pharmacy" + "ventilation_space_type_name": "patient_room_ventilation" }, { - "ventilation_space_type_name": "miscellaneous_spaces_photo_studios" + "ventilation_space_type_name": "pharmacy_ventilation" }, { - "ventilation_space_type_name": "miscellaneous_spaces_shipping_receiving" + "ventilation_space_type_name": "physical_therapy_ventilation" }, { - "ventilation_space_type_name": "miscellaneous_spaces_transportation_waiting" + "ventilation_space_type_name": "playing_area_ventilation" }, { - "ventilation_space_type_name": "miscellaneous_spaces_warehouses" + "ventilation_space_type_name": "plenum_ventilation" }, { - "ventilation_space_type_name": "miscellaneous_spaces_banks_bank_lobbies" + "ventilation_space_type_name": "post_office_ventilation" }, { - "ventilation_space_type_name": "miscellaneous_spaces_freezer_refrigerated_spaces" + "ventilation_space_type_name": "recovery_ventilation" }, { - "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_wo_hazardous_materials" + "ventilation_space_type_name": "recreation_common_living_ventilation" }, { - "ventilation_space_type_name": "miscellaneous_spaces_manufacturing_w_hazardous_materials" + "ventilation_space_type_name": "retail_sales_ventilation" }, { - "ventilation_space_type_name": "miscellaneous_spaces_sorting_packing_light_assembly" + "ventilation_space_type_name": "shaft_ventilation" }, { - "ventilation_space_type_name": "miscellaneous_spaces_telephone_closets" + "ventilation_space_type_name": "sleeping_quarters_ventilation" }, { - "ventilation_space_type_name": "public_assembly_spaces_auditorium_seating_area" + "ventilation_space_type_name": "sports_arena_ventilation" }, { - "ventilation_space_type_name": "public_assembly_spaces_religious_workshop" + "ventilation_space_type_name": "stairwell_ventilation" }, { - "ventilation_space_type_name": "public_assembly_spaces_courtrooms" + "ventilation_space_type_name": "storage_ventilation" }, { - "ventilation_space_type_name": "public_assembly_spaces_legislative_chambers" + "ventilation_space_type_name": "transportation_ventilation" }, { - "ventilation_space_type_name": "public_assembly_spaces_libraries" + "ventilation_space_type_name": "workshop_ventilation" }, { - "ventilation_space_type_name": "public_assembly_spaces_lobbies" + "ventilation_space_type_name": "worship_ventilation" }, { - "ventilation_space_type_name": "public_assembly_spaces_children_museums" + "ventilation_space_type_name": "correctional_facilities_booking_waiting_ventilation" }, { - "ventilation_space_type_name": "public_assembly_spaces_museums_galleries" + "ventilation_space_type_name": "correctional_facilities_day_room_ventilation" }, { - "ventilation_space_type_name": "retail_sales" + "ventilation_space_type_name": "correctional_facilities_guard_stations_ventilation" }, { - "ventilation_space_type_name": "retail_mall_common_areas" + "ventilation_space_type_name": "educational_facilities_art_classroom_ventilation" }, { - "ventilation_space_type_name": "retail_barbershop" + "ventilation_space_type_name": "educational_facilities_classrooms_ages_5-8_ventilation" }, { - "ventilation_space_type_name": "retail_beauty_nail_salons" + "ventilation_space_type_name": "educational_facilities_daycare_through_age_4_ventilation" }, { - "ventilation_space_type_name": "retail_pet_shops" + "ventilation_space_type_name": "educational_facilities_lecture_classroom_ventilation" }, { - "ventilation_space_type_name": "retail_supermarket" + "ventilation_space_type_name": "educational_facilities_lecture_hall_fixed_seats_ventilation" }, { - "ventilation_space_type_name": "retail_coin_operated_laundries" + "ventilation_space_type_name": "educational_facilities_media_center_ventilation" }, { - "ventilation_space_type_name": "sports_entertainment_sports_arena" + "ventilation_space_type_name": "educational_facilities_multi-use_assembly_ventilation" }, { - "ventilation_space_type_name": "sports_entertainment_gym_stadium" + "ventilation_space_type_name": "educational_facilities_music_theater_dance_ventilation" }, { - "ventilation_space_type_name": "sports_entertainment_spectator_areas" + "ventilation_space_type_name": "educational_facilities_science_laboratories_ventilation" }, { - "ventilation_space_type_name": "sports_entertainment_swimming" + "ventilation_space_type_name": "educational_facilities_wood_metal_shop_ventilation" }, { - "ventilation_space_type_name": "sports_entertainment_disco_dance_floors" + "ventilation_space_type_name": "food_and_beverage_service_bars_cocktail_lounges_ventilation" }, { - "ventilation_space_type_name": "sports_entertainment_health_club_aerobics_room" + "ventilation_space_type_name": "food_and_beverage_service_cafeteria_fast_food_dining_ventilation" }, { - "ventilation_space_type_name": "sports_entertainment_health_club_weight_rooms" + "ventilation_space_type_name": "hotels_motels_resorts_dormitories_lobbies_prefunction_ventilation" }, { - "ventilation_space_type_name": "sports_entertainment_bowling_alley" + "ventilation_space_type_name": "miscellaneous_spaces_bank_vaults_safe_deposit_ventilation" }, { - "ventilation_space_type_name": "sports_entertainment_gambling_casinos" + "ventilation_space_type_name": "miscellaneous_spaces_computer_not_printing_ventilation" }, { - "ventilation_space_type_name": "sports_entertainment_game_arcades" + "ventilation_space_type_name": "miscellaneous_spaces_photo_studios_ventilation" }, { - "ventilation_space_type_name": "sports_entertainment_stages_studios" + "ventilation_space_type_name": "miscellaneous_spaces_warehouses_ventilation" }, { - "ventilation_space_type_name": "animal_facilities_animal_exam_room" + "ventilation_space_type_name": "public_assembly_spaces_lobbies_ventilation" }, { - "ventilation_space_type_name": "animal_facilities_animal_imaging" + "ventilation_space_type_name": "public_assembly_spaces_museums_childrens_ventilation" }, { - "ventilation_space_type_name": "animal_facilities_animal_operating_rooms" + "ventilation_space_type_name": "retail_barber_shop_ventilation" }, { - "ventilation_space_type_name": "animal_facilities_animal_postoperative_recovery_room" + "ventilation_space_type_name": "retail_beauty_and_nail_salons_ventilation" }, { - "ventilation_space_type_name": "animal_facilities_animal_preparation_rooms" + "ventilation_space_type_name": "retail_coin-operated_laundries_ventilation" }, { - "ventilation_space_type_name": "animal_facilities_animal_procedure_room" + "ventilation_space_type_name": "retail_pet_shops_animal_areas_ventilation" }, { - "ventilation_space_type_name": "animal_facilities_animal_surgery_scrub" + "ventilation_space_type_name": "retail_supermarket_ventilation" }, { - "ventilation_space_type_name": "animal_facilities_large_animal_holding_room" + "ventilation_space_type_name": "sports_and_entertainment_bowling_alley_seating_ventilation" }, { - "ventilation_space_type_name": "animal_facilities_necropsy" + "ventilation_space_type_name": "sports_and_entertainment_disco_dance_floors_ventilation" }, { - "ventilation_space_type_name": "animal_facilities_small_animal_cage_room_static" + "ventilation_space_type_name": "sports_and_entertainment_gambling_casinos_ventilation" }, { - "ventilation_space_type_name": "animal_facilities_small_animal_cage_room_ventilated" + "ventilation_space_type_name": "sports_and_entertainment_game_arcades_ventilation" }, { - "ventilation_space_type_name": "outpatient_health_care_facilities_birthing_room" + "ventilation_space_type_name": "sports_and_entertainment_health_club_weight_rooms_ventilation" }, { - "ventilation_space_type_name": "outpatient_health_care_facilities_class_1_imaging_rooms" + "ventilation_space_type_name": "sports_and_entertainment_spectator_areas_ventilation" }, { - "ventilation_space_type_name": "outpatient_health_care_facilities_dental_operatory" + "ventilation_space_type_name": "sports_and_entertainment_stages_studios_ventilation" }, { - "ventilation_space_type_name": "outpatient_health_care_facilities_general_examination_room" + "ventilation_space_type_name": "sports_and_entertainment_swimming_pool_deck_ventilation" }, { - "ventilation_space_type_name": "outpatient_health_care_facilities_other_dental_treatment_areas" + "ventilation_space_type_name": "emergency_vehicle_garage_ventilation" }, { - "ventilation_space_type_name": "outpatient_health_care_facilities_physical_therapy_exercise_area" + "ventilation_space_type_name": "interior_parking_ventilation" }, { - "ventilation_space_type_name": "outpatient_health_care_facilities_physical_therapy_individual_room" + "ventilation_space_type_name": "restroom_ventilation" }, { - "ventilation_space_type_name": "outpatient_health_care_facilities_physical_therapeutic_pool_area" - }, - { - "ventilation_space_type_name": "outpatient_health_care_facilities_prosthetics_orthotics_room" - }, - { - "ventilation_space_type_name": "outpatient_health_care_facilities_psychiatric_consultation_room" - }, - { - "ventilation_space_type_name": "outpatient_health_care_facilities_psychiatric_examination_room" - }, - { - "ventilation_space_type_name": "outpatient_health_care_facilities_psychiatric_group_room" - }, - { - "ventilation_space_type_name": "outpatient_health_care_facilities_psychiatric_seclusion_room" - }, - { - "ventilation_space_type_name": "outpatient_health_care_facilities_speech_therapy_room" - }, - { - "ventilation_space_type_name": "outpatient_health_care_facilities_urgent_care_examination_room" - }, - { - "ventilation_space_type_name": "outpatient_health_care_facilities_urgent_care_observation_room" - }, - { - "ventilation_space_type_name": "outpatient_health_care_facilities_urgent_care_treatment_room" - }, - { - "ventilation_space_type_name": "outpatient_health_care_facilities_urgent_care_triage_room" - }, - { - "ventilation_space_type_name": "transient_residential_common_corridors" - }, - { - "ventilation_space_type_name": "transient_residential_dwelling_unit" + "ventilation_space_type_name": "vehicular_maintenance_ventilation" } ] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_tables/__init__.py b/data/openstudio_standards_data/database_tables/__init__.py index 73251ab19f..598d9e27bc 100644 --- a/data/openstudio_standards_data/database_tables/__init__.py +++ b/data/openstudio_standards_data/database_tables/__init__.py @@ -21,16 +21,27 @@ "hvac_minimum_requirement_boilers_90_1", "hvac_minimum_requirement_furnaces_90_1", "level_3_lighting_90_1_2019", + "level_3_lighting_90_1_2016", + "level_3_lighting_90_1_2013", + "level_3_lighting_90_1_2010", + "level_3_lighting_90_1_2007", "level_3_lighting_90_1_2004", - "level_3_ventilation_62_1_2004", "level_3_ventilation_62_1_2019", + "level_3_ventilation_62_1_2016", + "level_3_ventilation_62_1_2013", + "level_3_ventilation_62_1_2010", + "level_3_ventilation_62_1_2007", + "level_3_ventilation_62_1_2004", + "level_3_ventilation_62_1_1999", "level_2_electric_equipment", + "support_lighting_technologies", "support_standard_templates", "support_lighting_space_type_name_tags", "support_ventilation_space_type_name_tags", "support_electric_equipment_space_type_name_tags", "support_materials", "support_performance_curves", + "support_schedules", "system_requirement_energy_recovery_90_1", "system_requirement_economizer_90_1", # tables with foreign keys diff --git a/data/openstudio_standards_data/database_tables/level_1_space_types.py b/data/openstudio_standards_data/database_tables/level_1_space_types.py index d0b42b6200..54d1e6b010 100644 --- a/data/openstudio_standards_data/database_tables/level_1_space_types.py +++ b/data/openstudio_standards_data/database_tables/level_1_space_types.py @@ -9,6 +9,8 @@ lighting_space_type_name: TEXT ventilation_space_type_name: TEXT electric_equipment_space_type_name: TEXT +natural_gas_equipment_space_type_name: TEXT +schedule_set_name: TEXT """ CREATE_LEVEL_1_SPACE_TYPES = f""" @@ -18,6 +20,8 @@ lighting_space_type_name TEXT, ventilation_space_type_name TEXT, electric_equipment_space_type_name TEXT, +natural_gas_equipment_space_type_name TEXT, +schedule_set_name TEXT, FOREIGN KEY(lighting_space_type_name) REFERENCES support_lighting_space_type_name_tags(lighting_space_type_name) FOREIGN KEY(ventilation_space_type_name) REFERENCES support_ventilation_space_type_name_tags(ventilation_space_type_name) FOREIGN KEY(electric_equipment_space_type_name) REFERENCES support_electric_equipment_space_type_name_tags(support_electric_equipment_space_type_name_tags) @@ -26,8 +30,15 @@ INSERT_LEVEL_1_SPACE_TYPES = f""" INSERT INTO %s - (space_type_name, lighting_space_type_name, ventilation_space_type_name, electric_equipment_space_type_name) - VALUES (?, ?, ?, ?); + ( + space_type_name, + lighting_space_type_name, + ventilation_space_type_name, + electric_equipment_space_type_name, + natural_gas_equipment_space_type_name, + schedule_set_name + ) + VALUES (?, ?, ?, ?, ?, ?); """ @@ -36,6 +47,8 @@ "lighting_space_type_name": "", "ventilation_space_type_name": "", "electric_equipment_space_type_name": "", + "natural_gas_equipment_space_type_name": "", + "schedule_set_name": "", } @@ -56,6 +69,12 @@ def get_record_info(self): """ return RECORD_HELP + def _get_weak_foreign_key_value(self, record): + associate_table = getattr_either("support_schedules", record) + key = "name" + value = getattr_either("schedule_set_name", record) + return associate_table, key, value + def _preprocess_record(self, record): """ @@ -69,4 +88,6 @@ def _preprocess_record(self, record): getattr_either("lighting_space_type_name", record), getattr_either("ventilation_space_type_name", record), getattr_either("electric_equipment_space_type_name", record), + getattr_either("natural_gas_equipment_space_type_name", record), + getattr_either("schedule_set_name", record), ) diff --git a/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py b/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py index 78fa14bc03..47c0e5bf6a 100644 --- a/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py +++ b/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py @@ -6,30 +6,43 @@ RECORD_HELP = """ Must provide a tuple that contains: lighting_space_type_name: TEXT (unique) -level_3_lighting_definition_table: TEXT -level_3_lighting_definition_id: id from level_3_lighting_definition index +level_3_lighting_code_definition_table: TEXT +level_3_lighting_code_definition_id: id from level_3_lighting_definition index +lighting_technology_name: TEXT +lighting_space_type_target_illuminance_setpoint: NUMERIC """ -CREATE_LIGHT_SUBSPACE_TABLE = """ +CREATE_LIGHT_SUBSPACE_TABLE = f""" CREATE TABLE IF NOT EXISTS %s (id INTEGER PRIMARY KEY, lighting_space_type_name TEXT NOT NULL, -level_3_lighting_definition_table TEXT NOT NULL, -level_3_lighting_definition_id INTEGER NOT NULL, +level_3_lighting_code_definition_table TEXT NOT NULL, +level_3_lighting_code_definition_id INTEGER NOT NULL, +lighting_technology_name TEXT, +lighting_space_type_target_illuminance_setpoint NUMERIC, FOREIGN KEY(lighting_space_type_name) REFERENCES support_lighting_space_type_name_tags(lighting_space_type_name) +FOREIGN KEY(lighting_technology_name) REFERENCES support_lighting_technologies(lighting_technology_definition_name) ); """ INSERT_LIGHT_SUBSPACE = f""" INSERT INTO %s - (lighting_space_type_name, level_3_lighting_definition_table, level_3_lighting_definition_id) - VALUES (?, ?, ?); + ( + lighting_space_type_name, + level_3_lighting_code_definition_table, + level_3_lighting_code_definition_id, + lighting_technology_name, + lighting_space_type_target_illuminance_setpoint + ) + VALUES (?, ?, ?, ?, ?); """ RECORD_TEMPLATE = { "lighting_space_type_name": "", - "level_3_lighting_definition_table": "", - "level_3_lighting_definition_id": "", + "level_3_lighting_code_definition_table": "", + "level_3_lighting_code_definition_id": "", + "lighting_technology_name": "", + "lighting_space_type_target_illuminance_setpoint": 0.0, } @@ -64,8 +77,10 @@ def _preprocess_record(self, record): """ record_list = ( getattr_either("lighting_space_type_name", record), - getattr_either("level_3_lighting_definition_table", record), - getattr_either("level_3_lighting_definition_id", record), + getattr_either("level_3_lighting_code_definition_table", record), + getattr_either("level_3_lighting_code_definition_id", record), + getattr_either("lighting_technology_name", record), + getattr_either("lighting_space_type_target_illuminance_setpoint", record), ) return record_list diff --git a/data/openstudio_standards_data/database_tables/level_2_natural_gas_equipment.py b/data/openstudio_standards_data/database_tables/level_2_natural_gas_equipment.py new file mode 100644 index 0000000000..6e6620568b --- /dev/null +++ b/data/openstudio_standards_data/database_tables/level_2_natural_gas_equipment.py @@ -0,0 +1,91 @@ +import sqlite3 + +from database_engine.database import DBOperation +from database_engine.database_util import is_float, getattr_either + +TABLE_NAME = "level_2_natural_gas_equipment" + + +RECORD_HELP = """ +Must provide a tuple that contains: +natural_gas_equipment_space_type_name: TEXT +natural_gas_equipment_minimum_epd: REAL +natural_gas_equipment_average_epd: REAL +natural_gas_equipment_median_epd: REAL +natural_gas_equipment_maximum_epd: REAL +natural_gas_equipment_epd_unit: TEXT +""" + +CREATE_NATURAL_GAS_EQUIPMENT_TABLE = """ +CREATE TABLE IF NOT EXISTS %s +(id INTEGER PRIMARY KEY, +natural_gas_equipment_space_type_name TEXT NOT NULL, +natural_gas_equipment_minimum_epd NUMERIC, +natural_gas_equipment_average_epd NUMERIC, +natural_gas_equipment_median_epd NUMERIC, +natural_gas_equipment_maximum_epd NUMERIC, +natural_gas_equipment_epd_unit TEXT); +""" + +INSERT_NATURAL_GAS_EQUIP_LOAD_RECORD = """ + INSERT INTO %s + (natural_gas_equipment_space_type_name, natural_gas_equipment_minimum_epd, natural_gas_equipment_average_epd, natural_gas_equipment_median_epd, natural_gas_equipment_maximum_epd, natural_gas_equipment_epd_unit) + VALUES (?, ?, ?, ? , ? ,?); +""" + +RECORD_TEMPLATE = { + "natural_gas_equipment_space_type_name": "", + "natural_gas_equipment_minimum_epd": "", + "natural_gas_equipment_average_epd": "", + "natural_gas_equipment_median_epd": "", + "natural_gas_equipment_maximum_epd": "", + "natural_gas_equipment_epd_unit": "Btu/hr.ft2", +} + + +class EquipLoadTable(DBOperation): + def __init__(self): + super(EquipLoadTable, self).__init__( + table_name=TABLE_NAME, + record_template=RECORD_TEMPLATE, + initial_data_directory=f"database_files/{TABLE_NAME}", + create_table_query=CREATE_NATURAL_GAS_EQUIPMENT_TABLE % TABLE_NAME, + insert_record_query=INSERT_NATURAL_GAS_EQUIP_LOAD_RECORD % TABLE_NAME, + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def validate_record_datatype(self, record): + float_expected = [ + "natural_gas_equipment_minimum_epd", + "natural_gas_equipment_average_epd", + "natural_gas_equipment_median_epd", + "natural_gas_equipment_maximum_epd", + ] + + for f in float_expected: + if record.get(f): + assert is_float( + record.get(f) + ), f"{f} requires to be numeric data type, instead got {record[f]}" + + def _preprocess_record(self, record): + """ + + :param record: dictionary + :return: + """ + record_tuple = ( + getattr_either("natural_gas_equipment_space_type_name", record), + getattr_either("natural_gas_equipment_minimum_epd", record), + getattr_either("natural_gas_equipment_average_epd", record), + getattr_either("natural_gas_equipment_median_epd", record), + getattr_either("natural_gas_equipment_maximum_epd", record), + getattr_either("natural_gas_equipment_epd_unit", record, ""), + ) + return record_tuple diff --git a/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2007.py b/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2007.py new file mode 100644 index 0000000000..5353cbb38f --- /dev/null +++ b/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2007.py @@ -0,0 +1,13 @@ +import sqlite3 + +from database_tables.level_3_lighting_90_1_definition import LightDef901 + +TABLE_NAME = "level_3_lighting_90_1_2007" + + +class LightDef9012007Table(LightDef901): + def __init__(self): + super(LightDef9012007Table, self).__init__( + table_name=TABLE_NAME, + initial_data_directory=f"database_files/{TABLE_NAME}", + ) diff --git a/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2010.py b/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2010.py new file mode 100644 index 0000000000..4f0ad3bde4 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2010.py @@ -0,0 +1,13 @@ +import sqlite3 + +from database_tables.level_3_lighting_90_1_definition import LightDef901 + +TABLE_NAME = "level_3_lighting_90_1_2010" + + +class LightDef9012010Table(LightDef901): + def __init__(self): + super(LightDef9012010Table, self).__init__( + table_name=TABLE_NAME, + initial_data_directory=f"database_files/{TABLE_NAME}", + ) diff --git a/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2013.py b/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2013.py new file mode 100644 index 0000000000..cbdb8f68c1 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2013.py @@ -0,0 +1,13 @@ +import sqlite3 + +from database_tables.level_3_lighting_90_1_definition import LightDef901 + +TABLE_NAME = "level_3_lighting_90_1_2013" + + +class LightDef9012013Table(LightDef901): + def __init__(self): + super(LightDef9012013Table, self).__init__( + table_name=TABLE_NAME, + initial_data_directory=f"database_files/{TABLE_NAME}", + ) diff --git a/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2016.py b/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2016.py new file mode 100644 index 0000000000..4b7c8cb435 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_2016.py @@ -0,0 +1,13 @@ +import sqlite3 + +from database_tables.level_3_lighting_90_1_definition import LightDef901 + +TABLE_NAME = "level_3_lighting_90_1_2016" + + +class LightDef9012016Table(LightDef901): + def __init__(self): + super(LightDef9012016Table, self).__init__( + table_name=TABLE_NAME, + initial_data_directory=f"database_files/{TABLE_NAME}", + ) diff --git a/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_definition.py b/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_definition.py index 7b7456c932..070b12f375 100644 --- a/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_definition.py +++ b/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_definition.py @@ -9,33 +9,64 @@ lighting_primary_space_type: TEXT lighting_secondary_space_type: TEXT lighting_per_area: REAL -lighting_per_area_unit: TEXT +unit: TEXT +rcr_threshold: NUMERIC +automatic_daylight_responsive_controls_for_sidelighting: TEXT +automatic_daylight_responsive_controls_for_toplighting: TEXT +automatic_partial_off: TEXT +automatic_full_off: TEXT +scheduled_shutoff: TEXT annotation: TEXT (optional) """ CREATE_LIGHT_DEF_90_1_TABLE = """ -CREATE TABLE IF NOT EXISTS %s -(id INTEGER PRIMARY KEY, -method TEXT DEFAULT 'BA' NOT NULL, -lighting_primary_space_type TEXT, -lighting_per_area NUMERIC NOT NULL, +CREATE TABLE IF NOT EXISTS %s +(id INTEGER PRIMARY KEY, +method TEXT DEFAULT 'BA' NOT NULL, +lighting_primary_space_type TEXT, lighting_secondary_space_type TEXT, -lighting_per_area_unit TEXT DEFAULT 'w/ft2' NOT NULL, +lighting_power_density NUMERIC NOT NULL, +unit TEXT DEFAULT 'w/ft2' NOT NULL, +rcr_threshold NUMERIC, +automatic_daylight_responsive_controls_for_sidelighting TEXT, +automatic_daylight_responsive_controls_for_toplighting TEXT, +automatic_partial_off TEXT, +automatic_full_off TEXT, +scheduled_shutoff TEXT, annotation TEXT); """ INSERT_A_LIGHT_RECORD = """ INSERT INTO %s - (method, lighting_primary_space_type, lighting_secondary_space_type, lighting_per_area, lighting_per_area_unit, annotation) - VALUES (?, ?, ?, ? , ? ,?); + ( + method, + lighting_primary_space_type, + lighting_secondary_space_type, + lighting_power_density, + unit, + rcr_threshold, + automatic_daylight_responsive_controls_for_sidelighting, + automatic_daylight_responsive_controls_for_toplighting, + automatic_partial_off, + automatic_full_off, + scheduled_shutoff, + annotation + ) + VALUES (?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?); """ RECORD_TEMPLATE = { "method": "", "lighting_primary_space_type": "", "lighting_secondary_space_type": "", - "lighting_per_area": 0.0, - "lighting_per_area_unit": "W/ft2", + "lighting_power_density": 0.0, + "unit": "W/ft2", + "rcr_threshold": 0.0, + "automatic_daylight_responsive_controls_for_sidelighting": "", + "automatic_daylight_responsive_controls_for_toplighting": "", + "automatic_partial_off": "", + "automatic_full_off": "", + "scheduled_shutoff": "", "annotation": "", } @@ -80,8 +111,18 @@ def _preprocess_record(self, record): getattr_either("method", record), getattr_either("lighting_primary_space_type", record), getattr_either("lighting_secondary_space_type", record), - getattr_either("lighting_per_area", record), - getattr_either("lighting_per_area_unit", record, "W/ft2"), - getattr_either("annotation", record, ""), + getattr_either("lighting_power_density", record), + getattr_either("unit", record, "W/ft2"), + getattr_either("rcr_threshold", record), + getattr_either( + "automatic_daylight_responsive_controls_for_sidelighting", record + ), + getattr_either( + "automatic_daylight_responsive_controls_for_toplighting", record + ), + getattr_either("automatic_partial_off", record), + getattr_either("automatic_full_off", record), + getattr_either("scheduled_shutoff", record), + getattr_either("annotation", record), ) return record_tuple diff --git a/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_1999.py b/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_1999.py new file mode 100644 index 0000000000..ece3ebce56 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_1999.py @@ -0,0 +1,13 @@ +import sqlite3 + +from database_tables.level_3_ventilation_62_1_definition import VentDef621 + +TABLE_NAME = "level_3_ventilation_62_1_1999" + + +class VentDef6211999Table(VentDef621): + def __init__(self): + super(VentDef6211999Table, self).__init__( + table_name=TABLE_NAME, + initial_data_directory=f"database_files/{TABLE_NAME}", + ) diff --git a/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2007.py b/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2007.py new file mode 100644 index 0000000000..f73317803d --- /dev/null +++ b/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2007.py @@ -0,0 +1,13 @@ +import sqlite3 + +from database_tables.level_3_ventilation_62_1_definition import VentDef621 + +TABLE_NAME = "level_3_ventilation_62_1_2007" + + +class VentDef6212007Table(VentDef621): + def __init__(self): + super(VentDef6212007Table, self).__init__( + table_name=TABLE_NAME, + initial_data_directory=f"database_files/{TABLE_NAME}", + ) diff --git a/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2010.py b/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2010.py new file mode 100644 index 0000000000..a48536d2e7 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2010.py @@ -0,0 +1,13 @@ +import sqlite3 + +from database_tables.level_3_ventilation_62_1_definition import VentDef621 + +TABLE_NAME = "level_3_ventilation_62_1_2010" + + +class VentDef6212010Table(VentDef621): + def __init__(self): + super(VentDef6212010Table, self).__init__( + table_name=TABLE_NAME, + initial_data_directory=f"database_files/{TABLE_NAME}", + ) diff --git a/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2013.py b/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2013.py new file mode 100644 index 0000000000..f2e6cfbce2 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2013.py @@ -0,0 +1,13 @@ +import sqlite3 + +from database_tables.level_3_ventilation_62_1_definition import VentDef621 + +TABLE_NAME = "level_3_ventilation_62_1_2013" + + +class VentDef6212013Table(VentDef621): + def __init__(self): + super(VentDef6212013Table, self).__init__( + table_name=TABLE_NAME, + initial_data_directory=f"database_files/{TABLE_NAME}", + ) diff --git a/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2016.py b/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2016.py new file mode 100644 index 0000000000..bf17fdaa2a --- /dev/null +++ b/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_2016.py @@ -0,0 +1,13 @@ +import sqlite3 + +from database_tables.level_3_ventilation_62_1_definition import VentDef621 + +TABLE_NAME = "level_3_ventilation_62_1_2016" + + +class VentDef6212016Table(VentDef621): + def __init__(self): + super(VentDef6212016Table, self).__init__( + table_name=TABLE_NAME, + initial_data_directory=f"database_files/{TABLE_NAME}", + ) diff --git a/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_definition.py b/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_definition.py index 27db291329..b530ec0c2d 100644 --- a/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_definition.py +++ b/data/openstudio_standards_data/database_tables/level_3_ventilation_62_1_definition.py @@ -7,10 +7,10 @@ Must provide a tuple that contains: ventilation_primary_space_type: TEXT ventilation_secondary_space_type: TEXT -ventilation_per_person: NUMERIC -ventilation_per_person_unit: TEXT -ventilation_per_area: NUMERIC -ventilation_per_area_unit: TEXT, +ventilation_rate_occupant: NUMERIC +ventilation_rate_occupant_unit: TEXT +ventilation_rate_area: NUMERIC +ventilation_rate_area_unit: TEXT, occupancy_per_area: NUMERIC, occupancy_per_area_unit: TEXT air_class: INTEGER @@ -23,10 +23,10 @@ (id INTEGER PRIMARY KEY, ventilation_primary_space_type TEXT NOT NULL, ventilation_secondary_space_type TEXT NOT NULL, -ventilation_per_person NUMERIC, -ventilation_per_person_unit TEXT DEFAULT 'cfm/person', -ventilation_per_area NUMERIC, -ventilation_per_area_unit TEXT DEFAULT 'cfm/ft2', +ventilation_rate_occupant NUMERIC, +ventilation_rate_occupant_unit TEXT DEFAULT 'cfm/person', +ventilation_rate_area NUMERIC, +ventilation_rate_area_unit TEXT DEFAULT 'cfm/ft2', occupancy_per_area NUMERIC, occupancy_per_area_unit TEXT DEFAULT 'ppl/1000 ft2', air_class INTEGER, @@ -35,19 +35,29 @@ """ INSERT_A_VENT_RECORD = """ - INSERT INTO %s (ventilation_primary_space_type, -ventilation_secondary_space_type, ventilation_per_person, ventilation_per_person_unit, -ventilation_per_area, ventilation_per_area_unit, occupancy_per_area, occupancy_per_area_unit, air_class, os, annotation) + INSERT INTO %s ( +ventilation_primary_space_type, +ventilation_secondary_space_type, +ventilation_rate_occupant, +ventilation_rate_occupant_unit, +ventilation_rate_area, +ventilation_rate_area_unit, +occupancy_per_area, +occupancy_per_area_unit, +air_class, +os, +annotation +) VALUES (?, ?, ?, ? ,? ,? , ?, ?, ?, ?, ?); """ RECORD_TEMPLATE = { "ventilation_primary_space_type": "", "ventilation_secondary_space_type": "", - "ventilation_per_person": 0.0, - "ventilation_per_person_unit": "cfm/person", - "ventilation_per_area": 0.0, - "ventilation_per_area_unit": "cfm/ft2", + "ventilation_rate_occupant": 0.0, + "ventilation_rate_occupant_unit": "cfm/person", + "ventilation_rate_area": 0.0, + "ventilation_rate_area_unit": "cfm/ft2", "occupancy_per_area": 0.0, "occupancy_per_area_unit": "ppl/1000 ft2", "air_class": 0, @@ -75,8 +85,8 @@ def get_record_info(self): def validate_record_datatype(self, record): float_expected = [ - "ventilation_per_person", - "ventilation_per_area", + "ventilation_rate_occupant", + "ventilation_rate_area", "occupancy_per_area", ] @@ -97,10 +107,10 @@ def _preprocess_record(self, record): return ( getattr_either("ventilation_primary_space_type", record), getattr_either("ventilation_secondary_space_type", record), - getattr_either("ventilation_per_person", record), - getattr_either("ventilation_per_person_unit", record, "cfm/person"), - getattr_either("ventilation_per_area", record), - getattr_either("ventilation_per_area_unit", record, "cfm/ft2"), + getattr_either("ventilation_rate_occupant", record), + getattr_either("ventilation_rate_occupant_unit", record, "cfm/person"), + getattr_either("ventilation_rate_area", record), + getattr_either("ventilation_rate_area_unit", record, "cfm/ft2"), getattr_either("occupancy_per_area", record), getattr_either("occupancy_per_area_unit", record, "ppl/1000 ft2"), getattr_either("air_class", record), diff --git a/data/openstudio_standards_data/database_tables/support_lighting_technologies.py b/data/openstudio_standards_data/database_tables/support_lighting_technologies.py new file mode 100644 index 0000000000..99b96ef18a --- /dev/null +++ b/data/openstudio_standards_data/database_tables/support_lighting_technologies.py @@ -0,0 +1,159 @@ +from database_engine.database import DBOperation +from database_engine.database_util import getattr_either, is_float + +TABLE_NAME = "support_lighting_technologies" + +RECORD_HELP = """ +Must provide a tuple that contains: +lighting_technology_definition_name: TEXT (unique) +lighting_fraction_to_return_air: NUMERIC +lighting_fraction_radiant: NUMERIC +lighting_fraction_visible: NUMERIC +lighting_fraction_replaceable: NUMERIC +lpd_fraction_linear_fluorescent: NUMERIC +lpd_fraction_compact_fluorescent: NUMERIC +lpd_fraction_high_bay: NUMERIC +lpd_fraction_specialty_lighting: NUMERIC +lpd_fraction_exit_lighting: NUMERIC +compact_fluorescent_lighting_schedule: TEXT +high_bay_lighting_schedule: TEXT +specialty_lighting_schedule: TEXT +exit_lighting_schedule: TEXT +""" + +LIGHT_TECHNOLOGIES_TABLE = f""" +CREATE TABLE IF NOT EXISTS %s +(lighting_technology_definition_name TEXT UNIQUE NOT NULL PRIMARY KEY, +lighting_fraction_to_return_air NUMERIC, +lighting_fraction_radiant NUMERIC, +lighting_fraction_visible NUMERIC, +lighting_fraction_replaceable NUMERIC, +lpd_fraction_linear_fluorescent NUMERIC, +lpd_fraction_compact_fluorescent NUMERIC, +lpd_fraction_high_bay NUMERIC, +lpd_fraction_specialty_lighting NUMERIC, +lpd_fraction_exit_lighting NUMERIC, +compact_fluorescent_lighting_schedule TEXT, +high_bay_lighting_schedule TEXT, +specialty_lighting_schedule TEXT, +exit_lighting_schedule TEXT +); +""" + +INSERT_LIGHT_TECHNOLOGY = f""" + INSERT INTO %s + ( +lighting_technology_definition_name, +lighting_fraction_to_return_air, +lighting_fraction_radiant, +lighting_fraction_visible, +lighting_fraction_replaceable, +lpd_fraction_linear_fluorescent, +lpd_fraction_compact_fluorescent, +lpd_fraction_high_bay, +lpd_fraction_specialty_lighting, +lpd_fraction_exit_lighting, +compact_fluorescent_lighting_schedule, +high_bay_lighting_schedule, +specialty_lighting_schedule, +exit_lighting_schedule + ) + VALUES (?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?); +""" + +RECORD_TEMPLATE = { + "lighting_technology_definition_name": "", + "lighting_fraction_to_return_air": 0.0, + "lighting_fraction_radiant": 0.0, + "lighting_fraction_visible": 0.0, + "lighting_fraction_replaceable": 0.0, + "lpd_fraction_linear_fluorescent": 0.0, + "lpd_fraction_compact_fluorescent": 0.0, + "lpd_fraction_high_bay": 0.0, + "lpd_fraction_specialty_lighting": 0.0, + "lpd_fraction_exit_lighting": 0.0, + "linear_fluorescent_lighting_schedule": "", + "compact_fluorescent_lighting_schedule": "", + "high_bay_lighting_schedule": "", + "specialty_lighting_schedule": "", + "exit_lighting_schedule": "", +} + + +class SupportLightTechnologiesTable(DBOperation): + def __init__(self): + super(SupportLightTechnologiesTable, self).__init__( + table_name=TABLE_NAME, + record_template=RECORD_TEMPLATE, + initial_data_directory=f"database_files/{TABLE_NAME}", + create_table_query=LIGHT_TECHNOLOGIES_TABLE % TABLE_NAME, + insert_record_query=INSERT_LIGHT_TECHNOLOGY % TABLE_NAME, + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def validate_record_datatype(self, record): + str_expected = [ + "lighting_technology_definition_name", + "compact_fluorescent_lighting_schedule", + "high_bay_lighting_schedule", + "specialty_lighting_schedule", + "specialty_lighting_schedule", + "exit_lighting_schedule", + ] + + for f in str_expected: + if record.get(f): + assert isinstance( + record[f], str + ), f"{f} requires to be a string, instead got {record[f]}" + + float_expected = [ + "lighting_fraction_to_return_air", + "lighting_fraction_radiant", + "lighting_fraction_visible", + "lighting_fraction_replaceable", + "lpd_fraction_linear_fluorescent", + "lpd_fraction_compact_fluorescent", + "lpd_fraction_high_bay", + "lpd_fraction_specialty_lighting", + "lpd_fraction_exit_lighting", + ] + + for f in float_expected: + if record.get(f): + assert is_float( + record.get(f) + ), f"{f} requires to be numeric data type, instead got {record[f]}" + + return True + + def _preprocess_record(self, record): + """ + + :param record: dict + :return: + """ + record_list = ( + getattr_either("lighting_technology_definition_name", record), + getattr_either("lighting_fraction_to_return_air", record), + getattr_either("lighting_fraction_radiant", record), + getattr_either("lighting_fraction_visible", record), + getattr_either("lighting_fraction_replaceable", record), + getattr_either("lpd_fraction_linear_fluorescent", record), + getattr_either("lpd_fraction_compact_fluorescent", record), + getattr_either("lpd_fraction_high_bay", record), + getattr_either("lpd_fraction_specialty_lighting", record), + getattr_either("lpd_fraction_exit_lighting", record), + getattr_either("compact_fluorescent_lighting_schedule", record), + getattr_either("high_bay_lighting_schedule", record), + getattr_either("specialty_lighting_schedule", record), + getattr_either("exit_lighting_schedule", record), + ) + + return record_list diff --git a/data/openstudio_standards_data/database_tables/support_schedules.py b/data/openstudio_standards_data/database_tables/support_schedules.py new file mode 100644 index 0000000000..a5083948f8 --- /dev/null +++ b/data/openstudio_standards_data/database_tables/support_schedules.py @@ -0,0 +1,261 @@ +from database_engine.database import DBOperation +from database_engine.database_util import getattr_either, is_float + +TABLE_NAME = "support_schedules" + +RECORD_HELP = """ +Must provide a dict that contains following key value pairs: +name: TEXT +category: TEXT +units: TEXT +day_types: TEXT +start_date: TEXT +end_date: TEXT +type: TEXT +hr_1: NUMERIC +hr_2: NUMERIC +hr_3: NUMERIC +hr_4: NUMERIC +hr_5: NUMERIC +hr_6: NUMERIC +hr_7: NUMERIC +hr_8: NUMERIC +hr_9: NUMERIC +hr_10: NUMERIC +hr_11: NUMERIC +hr_12: NUMERIC +hr_13: NUMERIC +hr_14: NUMERIC +hr_15: NUMERIC +hr_16: NUMERIC +hr_17: NUMERIC +hr_18: NUMERIC +hr_19: NUMERIC +hr_20: NUMERIC +hr_21: NUMERIC +hr_22: NUMERIC +hr_23: NUMERIC +hr_24: NUMERIC +annotation: TEXT +""" + +CREATE_SCHEDULES_TABLE = f""" +CREATE TABLE IF NOT EXISTS %s +(id INTEGER PRIMARY KEY, +name TEXT NOT NULL, +category TEXT NOT NULL, +units TEXT, +day_types TEXT NOT NULL, +start_date TEXT NOT NULL, +end_date TEXT NOT NULL, +type TEXT NOT NULL, +hr_1 NUMERIC NOT NULL, +hr_2 NUMERIC NOT NULL, +hr_3 NUMERIC NOT NULL, +hr_4 NUMERIC NOT NULL, +hr_5 NUMERIC NOT NULL, +hr_6 NUMERIC NOT NULL, +hr_7 NUMERIC NOT NULL, +hr_8 NUMERIC NOT NULL, +hr_9 NUMERIC NOT NULL, +hr_10 NUMERIC NOT NULL, +hr_11 NUMERIC NOT NULL, +hr_12 NUMERIC NOT NULL, +hr_13 NUMERIC NOT NULL, +hr_14 NUMERIC NOT NULL, +hr_15 NUMERIC NOT NULL, +hr_16 NUMERIC NOT NULL, +hr_17 NUMERIC NOT NULL, +hr_18 NUMERIC NOT NULL, +hr_19 NUMERIC NOT NULL, +hr_20 NUMERIC NOT NULL, +hr_21 NUMERIC NOT NULL, +hr_22 NUMERIC NOT NULL, +hr_23 NUMERIC NOT NULL, +hr_24 NUMERIC NOT NULL, +annotation TEXT +); +""" + +INSERT_SCHEDULE = f""" + INSERT INTO %s + (name, +category, +units, +day_types, +start_date, +end_date, +type, +hr_1, +hr_2, +hr_3, +hr_4, +hr_5, +hr_6, +hr_7, +hr_8, +hr_9, +hr_10, +hr_11, +hr_12, +hr_13, +hr_14, +hr_15, +hr_16, +hr_17, +hr_18, +hr_19, +hr_20, +hr_21, +hr_22, +hr_23, +hr_24, +annotation) + VALUES (?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?); +""" + + +RECORD_TEMPLATE = { + "name": "", + "category": "", + "units": "", + "day_types": "", + "start_date": "", + "end_date": "", + "type": "", + "hr_1": 0.0, + "hr_2": 0.0, + "hr_3": 0.0, + "hr_4": 0.0, + "hr_5": 0.0, + "hr_6": 0.0, + "hr_7": 0.0, + "hr_8": 0.0, + "hr_9": 0.0, + "hr_10": 0.0, + "hr_11": 0.0, + "hr_12": 0.0, + "hr_13": 0.0, + "hr_14": 0.0, + "hr_15": 0.0, + "hr_16": 0.0, + "hr_17": 0.0, + "hr_18": 0.0, + "hr_19": 0.0, + "hr_20": 0.0, + "hr_21": 0.0, + "hr_22": 0.0, + "hr_23": 0.0, + "hr_24": 0.0, +} + + +class SupportScheduleTable(DBOperation): + def __init__(self): + super(SupportScheduleTable, self).__init__( + table_name=TABLE_NAME, + record_template=RECORD_TEMPLATE, + initial_data_directory=f"database_files/{TABLE_NAME}", + create_table_query=CREATE_SCHEDULES_TABLE % TABLE_NAME, + insert_record_query=INSERT_SCHEDULE % TABLE_NAME, + ) + + def get_record_info(self): + """ + A function to return the record info of the table + :return: + """ + return RECORD_HELP + + def validate_record_datatype(self, record): + str_expected = [ + "name", + "category", + "units", + "day_types", + "start_date", + "end_date", + "type", + ] + + for f in str_expected: + if record.get(f): + assert isinstance( + record[f], str + ), f"{f} requires to be a string, instead got {record[f]}" + + float_expected = [ + "hr_1", + "hr_2", + "hr_3", + "hr_4", + "hr_5", + "hr_6", + "hr_7", + "hr_8", + "hr_9", + "hr_10", + "hr_11", + "hr_12", + "hr_13", + "hr_14", + "hr_15", + "hr_16", + "hr_17", + "hr_18", + "hr_19", + "hr_20", + "hr_21", + "hr_22", + "hr_23", + "hr_24", + ] + + for f in float_expected: + if record.get(f): + assert is_float( + record.get(f) + ), f"{f} requires to be numeric data type, instead got {record[f]}" + return True + + def _preprocess_record(self, record): + """ + + :param record: dict + :return: + """ + + return ( + getattr_either("name", record), + getattr_either("category", record), + getattr_either("units", record), + getattr_either("day_types", record), + getattr_either("start_date", record), + getattr_either("end_date", record), + getattr_either("type", record), + getattr_either("hr_1", record), + getattr_either("hr_2", record), + getattr_either("hr_3", record), + getattr_either("hr_4", record), + getattr_either("hr_5", record), + getattr_either("hr_6", record), + getattr_either("hr_7", record), + getattr_either("hr_8", record), + getattr_either("hr_9", record), + getattr_either("hr_10", record), + getattr_either("hr_11", record), + getattr_either("hr_12", record), + getattr_either("hr_13", record), + getattr_either("hr_14", record), + getattr_either("hr_15", record), + getattr_either("hr_16", record), + getattr_either("hr_17", record), + getattr_either("hr_18", record), + getattr_either("hr_19", record), + getattr_either("hr_20", record), + getattr_either("hr_21", record), + getattr_either("hr_22", record), + getattr_either("hr_23", record), + getattr_either("hr_24", record), + getattr_either("annotation", record), + ) diff --git a/data/openstudio_standards_data/query/fetch/space.py b/data/openstudio_standards_data/query/fetch/space.py index c88222468c..771bc58218 100644 --- a/data/openstudio_standards_data/query/fetch/space.py +++ b/data/openstudio_standards_data/query/fetch/space.py @@ -10,8 +10,8 @@ "space_type", "lighting_space_type_name", "ventilation_space_type_name", - "level_3_lighting_definition_table", - "level_3_lighting_definition_id", + "level_3_lighting_code_definition_table", + "level_3_lighting_code_definition_id", "level_3_ventilation_definition_table", "level_3_ventilation_definition_id", "electric_equipment_space_type_name", From f6924e7fc38e9b6f492416b42c695df3a246a159 Mon Sep 17 00:00:00 2001 From: Jeremy L <5149279+lymereJ@users.noreply.github.com> Date: Thu, 30 Mar 2023 15:00:10 -0700 Subject: [PATCH 17/45] Update export function for space type data. (#1482) --- .../create_openstudio_standards_json.py | 356 +- .../level_2_natural_gas_equipment.csv | 12 +- .../level_2_natural_gas_equipment.json | 50 + .../level_2_ventilation_space_types.csv | 32 +- .../level_2_ventilation_space_types.json | 32 +- .../level_3_lighting_90_1_2016.csv | 24 +- .../level_3_ventilation_62_1_2007.csv | 2 +- .../level_3_ventilation_62_1_2007.json | 2 +- .../level_3_ventilation_62_1_2010.csv | 2 +- .../level_3_ventilation_62_1_2010.json | 2 +- .../level_3_ventilation_62_1_2013.csv | 4 +- .../level_3_ventilation_62_1_2013.json | 4 +- .../level_3_ventilation_62_1_2016.csv | 4 +- .../level_3_ventilation_62_1_2016.json | 4 +- .../level_3_ventilation_62_1_2019.csv | 2 +- .../level_3_ventilation_62_1_2019.json | 2 +- .../database_files/support_schedules.csv | 1620 ++++----- .../database_files/support_schedules.json | 3240 ++++++++--------- .../database_tables/__init__.py | 1 + .../level_2_natural_gas_equipment.py | 1 + .../query/fetch/space.py | 26 +- 21 files changed, 2841 insertions(+), 2581 deletions(-) create mode 100644 data/openstudio_standards_data/database_files/level_2_natural_gas_equipment.json diff --git a/data/openstudio_standards_data/applications/create_openstudio_standards_json.py b/data/openstudio_standards_data/applications/create_openstudio_standards_json.py index 715df4b3c5..067d45f82a 100644 --- a/data/openstudio_standards_data/applications/create_openstudio_standards_json.py +++ b/data/openstudio_standards_data/applications/create_openstudio_standards_json.py @@ -10,91 +10,272 @@ fetch_table, fetch_records_from_table_by_key_values, ) -from query.fetch.template import fetch_templates -def create_openstudio_standards_space_data_json( - conn: sqlite3.Connection, json_data_dir: str +def create_openstudio_standards_space_data_json_ashrae_90_1( + conn: sqlite3.Connection, version_90_1: str ): + """Create and export space type related data for a specific version of ASHRAE 90.1 to be used by OpenStudio Standards + + :param conn (sqlite3.Connection): database connection + :param version_90_1 (str): code version of ASHRAE 90.1, e.g. "2004", "2007", etc. + """ + missing_data_lookup_hierarchy = [ + "1999", + "2004", + "2007", + "2010", + "2013", + "2016", + "2019", + ] + code = "ashrae_90_1" + template = f"90.1-{version_90_1}" + create_openstudio_standards_space_data_json( + conn, template, version_90_1, missing_data_lookup_hierarchy, code + ) + + +def is_record_present(records: list, field: str, value: str) -> bool | dict: + """Check if a record (field, value pair) is available among a set of records + + :param records (list): list of records + :param field (str): field to search + :param value (str): targeted value of the field + :return: false if record cannot be found otherwise record (dict) """ - Extract OpenSutdio Standards building data to a json file. - :param conn: database connection - :param json_data_dir: directory - :return: + for r in records: + if value in r[field]: + return r + return False + + +def find_closest_record( + records: list, field: str, value: str, missing_data_lookup_hierarchy: list +) -> dict: + """Find closest available record to a value from a data lookup hierarchy + + :param records (list): list of records + :param field (str): field to search + :param value (str): targeted value of the field + :param missing_data_lookup_hierarchy (list): list (ordered) of values to use to look up record if targeted value cannot be found + :return: record (dict) """ - space_data = [] + r = is_record_present(records, field, value) + if r is False: + for code in missing_data_lookup_hierarchy: + r_next = is_record_present(records, field, code) + if isinstance(r_next, dict): + return r_next + assert r + else: + return r - # Step 1, we need to get the template table and loop in the table - standard_templates = fetch_templates(conn) - # Step 2, get all building -> light and vent map table + +def create_openstudio_standards_space_data_json( + conn: sqlite3.Connection, + template: str, + code_version: str, + missing_data_lookup_hierarchy: list, + code: str, +): + """Extract code- and code version-specific OpenStudio Standards space type data from the database and export it to JSON files + :param conn (sqlite3.Connection): database connection + :param template (str): template corresponding to the code and code version, e.g. "90.1-2004", or "90.1-2007" + :param code_version (str): verion of the code, e.g. "2004", "2007", etc. + :param missing_data_lookup_hierarchy (list): list (ordered) of values to use to look up record if targeted value cannot be found + :param code (str): name of the building energy code, e.g. "ashrae_90_1" + """ space_map_table = fetch_space_data(conn) - # Step 3, create an empty data holder to serve a memoize storage for standard tables - standard_data_tables = dict() - - for template in standard_templates: - lighting_standard_table = template["lighting_standard_table"] - ventilation_standard_table = template["ventilation_standard_table"] - # filter out the matching lighting standard table and ventilation standard table - subset_space_map_table = filter( - lambda bldg: bldg["level_3_lighting_code_definition_table"] - == lighting_standard_table - and bldg["level_3_ventilation_definition_table"] - == ventilation_standard_table, - space_map_table, - ) - for space in subset_space_map_table: - # WX: I tried to avoid having queries inside the loop but this seems to be a decision to make either loop - # the queries or pre-query each standard version tables outside the loop but increase the maintenance effort - sp_data = dict() - sp_data["template"] = template["template"] - sp_data["lighting_standard"] = template["lighting_standard"] - sp_data["ventilation_standard"] = template["ventilation_standard"] - sp_data["space_type"] = space["space_type"] - - lpd_id = int(space["level_3_lighting_code_definition_id"]) - vent_id = int(space["level_3_ventilation_defintion_id"]) - if lighting_standard_table not in standard_data_tables.keys(): - light_table = fetch_table(conn, lighting_standard_table) - standard_data_tables[lighting_standard_table] = light_table - if ventilation_standard_table not in standard_data_tables.keys(): - vent_table = fetch_table(conn, ventilation_standard_table) - standard_data_tables[ventilation_standard_table] = vent_table - if space.get("electric_equipment_space_type_name"): - plug_load_record = fetch_records_from_table_by_key_values( - conn, - "equip_load", - { - "electric_equipment_space_type_name": space[ - "electric_equipment_space_type_name" + # Drop other code versions + space_map_table = [ + rec + for rec in space_map_table + if f"{code.replace('ashrae_', '')}_{code_version}" + in rec["LS.level_3_lighting_code_definition_table"] + ] + + space_types = {"space_types": []} + space_type_names = [] + for space_type_infos in space_map_table: + space_type_name = space_type_infos["space_type_name"] + if not space_type_name in space_type_names: + space_type_names.append(space_type_name) + lighting_space_type_name = space_type_infos["BS.lighting_space_type_name"] + space_type_data = {"template": template, "space_type": space_type_name} + + # Get lighting space type data + lighting_space_type_data = fetch_records_from_table_by_key_values( + conn, + "level_2_lighting_space_types", + {"lighting_space_type_name": lighting_space_type_name}, + ) + assert len(lighting_space_type_data) > 0 + r = find_closest_record( + lighting_space_type_data, + "level_3_lighting_code_definition_table", + code_version, + missing_data_lookup_hierarchy, + ) + + # Get illuminance SP + space_type_data["target_illuminance_setpoint"] = r[ + "lighting_space_type_target_illuminance_setpoint" + ] + + # Get LPD + lighting_records = fetch_records_from_table_by_key_values( + conn, + r["level_3_lighting_code_definition_table"], + {"id": r["level_3_lighting_code_definition_id"]}, + )[0] + + space_lpd = float(lighting_records["lighting_power_density"]) + space_lpd_unit = lighting_records["unit"] + if space_lpd_unit.lower() == "w/ft2": + space_type_data["lighting_per_area"] = space_lpd + space_type_data["lighting_per_height"] = 0.0 + elif space_lpd_unit.lower() == "w/ft": + space_type_data["lighting_per_area"] = 0.0 + space_type_data["lighting_per_height"] = space_lpd + space_type_data["lighting_per_person"] = 0.0 + space_type_data["rcr"] = lighting_records["rcr_threshold"] + + # Get space technology-based lighting information + lighting_tech_name = r["lighting_technology_name"] + lighting_tech_records = fetch_records_from_table_by_key_values( + conn, + "support_lighting_technologies", + {"lighting_technology_definition_name": lighting_tech_name}, + )[0] + lighting_tech_fields = [ + "lighting_fraction_to_return_air", + "lighting_fraction_radiant", + "lighting_fraction_visible", + "lighting_fraction_replaceable", + "lpd_fraction_linear_fluorescent", + "lpd_fraction_compact_fluorescent", + "lpd_fraction_high_bay", + "lpd_fraction_specialty_lighting", + "lpd_fraction_exit_lighting", + "compact_fluorescent_lighting_schedule", + "high_bay_lighting_schedule", + "specialty_lighting_schedule", + "exit_lighting_schedule", + ] + for f in lighting_tech_fields: + space_type_data[f] = lighting_tech_records[f] + + # Get equipment space type data + electric_equipment_space_type_name = space_type_infos[ + "ES.electric_equipment_space_type_name" + ] + electric_equipment_space_type_data = fetch_records_from_table_by_key_values( + conn, + "level_2_electric_equipment", + { + "electric_equipment_space_type_name": electric_equipment_space_type_name + }, + ) + if isinstance(electric_equipment_space_type_data, list): + if len(electric_equipment_space_type_data) > 0: + space_type_data["electric_equipment_per_area"] = float( + electric_equipment_space_type_data[0][ + "electric_equipment_average_epd" ] - }, - ) - if plug_load_record: - # Get the first record in the list. - plug_load_record = plug_load_record[0] + ) + else: + space_type_data["electric_equipment_per_area"] = 0.0 else: - plug_load_record = plug_load_record_template - light = next( - ltg - for ltg in standard_data_tables[lighting_standard_table] - if ltg["id"] == lpd_id + space_type_data["electric_equipment_per_area"] = 0.0 + + natural_gas_equipment_space_type_name = space_type_infos[ + "EGS.natural_gas_equipment_space_type_name" + ] + natural_gas_equipment_space_type_data = fetch_records_from_table_by_key_values( + conn, + "level_2_natural_gas_equipment", + { + "natural_gas_equipment_space_type_name": natural_gas_equipment_space_type_name + }, ) - vent = next( - vt - for vt in standard_data_tables[ventilation_standard_table] - if vt["id"] == vent_id + if isinstance(natural_gas_equipment_space_type_data, list): + if len(natural_gas_equipment_space_type_data) > 0: + space_type_data["natural_gas_equipment_per_area"] = float( + natural_gas_equipment_space_type_data[0][ + "natural_gas_equipment_average_epd" + ] + ) + else: + space_type_data["natural_gas_equipment_per_area"] = 0.0 + else: + space_type_data["natural_gas_equipment_per_area"] = 0.0 + + # Get ventilation and occupancy space type data + ventilation_space_type_name = space_type_infos[ + "BS.ventilation_space_type_name" + ] + ventilation_space_type_data = fetch_records_from_table_by_key_values( + conn, + "level_2_ventilation_space_types", + {"ventilation_space_type_name": ventilation_space_type_name}, ) - sp_data.update(light) - sp_data.update(vent) - sp_data.update(plug_load_record) - # delete ID parameter, the ID is database specific and does not need - # included in the json - sp_data.pop("id", None) - - space_data.append(sp_data) - - with open(json_data_dir, "w") as output_report: - output_report.write(json.dumps(space_data, indent=4)) + assert len(ventilation_space_type_data) > 0 + r = find_closest_record( + ventilation_space_type_data, + "level_3_ventilation_definition_table", + code_version, + missing_data_lookup_hierarchy, + ) + ventilation_records = fetch_records_from_table_by_key_values( + conn, + r["level_3_ventilation_definition_table"], + {"id": r["level_3_ventilation_definition_id"]}, + )[0] + vent_per_pers = ( + ventilation_records["ventilation_rate_occupant"] + if not ventilation_records["ventilation_rate_occupant"] is None + else 0.0 + ) + vent_per_area = ( + ventilation_records["ventilation_rate_area"] + if not ventilation_records["ventilation_rate_area"] is None + else 0.0 + ) + occ_per_area = ( + ventilation_records["occupancy_per_area"] + if not ventilation_records["occupancy_per_area"] is None + else 0.0 + ) + space_type_data["ventilation_per_person"] = vent_per_pers + # assume unit is cfm/pers; TODO: unit check + space_type_data["ventilation_per_area"] = vent_per_area + # assume unit is cfm/ft2; TODO: unit check + space_type_data["ventilation_air_changes"] = 0.0 + space_type_data[ + "occupancy_per_area" + ] = occ_per_area # assume unit is people / 1000 ft2; TODO: unit check + + # Schedules + schedule_set_name = space_type_infos["BS.schedule_set_name"] + space_type_data[ + "electric_equipment_schedule" + ] = f"{schedule_set_name}_equipment" + space_type_data["gas_equipment_schedule"] = f"{schedule_set_name}_equipment" + space_type_data["lighting_schedule"] = f"{schedule_set_name}_lighting" + space_type_data["occupancy_schedule"] = f"{schedule_set_name}_occupancy" + + space_types["space_types"].append(space_type_data) + + # Export retrieved data + if len(space_types) > 0: + with open( + f"../../lib/openstudio-standards/standards/{code}/{code}_{code_version}/data/{code}_{code_version}.space_types.json", + "w+", + ) as output_report: + output_report.write(json.dumps(space_types, indent=2)) + else: + logging.warning(f"No records were found") def create_openstudio_standards_data_json_ashrae_90_1( @@ -143,6 +324,7 @@ def create_openstudio_standards_data_json_ashrae_90_1( "materials": "support_materials", "constructions": "support_constructions", "curves": "support_performance_curves", + "space_type_schedules": "support_schedules", } # Generate and "export" the data to the correct location within the OpenStudio Standards repository @@ -158,8 +340,7 @@ def create_openstudio_standards_code_version_data_json( template: str, tables_to_export: dict, ) -> None: - """ - Extract code- and code version-specific OpenStudio Standards data from the database and export it to JSON files + """Extract code- and code version-specific OpenStudio Standards data from the database and export it to JSON files :param conn (sqlite3.Connection): database connection :param code (str): name of the building energy code, e.g. "ashrae_90_1" :param code_version (str): verion of the code, e.g. "2004", "2007", etc. @@ -251,7 +432,16 @@ def process_records(records: list) -> list: if key in list(record.keys()): del record[key] + # Concatenate schedule name a category + schedule_record = False + if all( + i in list(record.keys()) for i in ["name", "category", "day_types", "hr_1"] + ): + record["name"] = f"{record['name']}_{record['category'].lower()}" + schedule_record = True + materials = [] + hr_values = [] for key, value in record.items(): # Reformat date if "_date" in key: @@ -268,19 +458,31 @@ def process_records(records: list) -> list: if value == "FALSE": record[key] = False - # Identify of the data is part of an "enumeration" of material + # Identify of the data is part of an "enumeration" of material or schedules # e.g., is the key "material_1", or "material_2", etc. material_id = key.split("material_")[-1] + hour_id = key.split("hr_")[-1] try: material_id = int(material_id) except: pass + try: + hour_id = int(hour_id) + except: + pass if isinstance(material_id, int) and not value is None: materials.append(value) + if isinstance(hour_id, int) and not value is None: + hr_values.append(value) # Create a list of materials instead of having multiple material key/value pairs if len(materials) > 0: for i in range(1, 7): del record[f"material_{i}"] record["materials"] = materials + # Create a list of schedule values instead of having multiple hour key/value pairs + if len(hr_values) > 0: + for i in range(1, 25): + del record[f"hr_{i}"] + record["values"] = hr_values return records diff --git a/data/openstudio_standards_data/database_files/level_2_natural_gas_equipment.csv b/data/openstudio_standards_data/database_files/level_2_natural_gas_equipment.csv index b842378127..c77fc657c4 100644 --- a/data/openstudio_standards_data/database_files/level_2_natural_gas_equipment.csv +++ b/data/openstudio_standards_data/database_files/level_2_natural_gas_equipment.csv @@ -1,7 +1,7 @@ natural_gas_equipment_space_type_name,natural_gas_equipment_minimum_epd,natural_gas_equipment_average_epd,natural_gas_equipment_median_epd,natural_gas_equipment_maximum_epd,natural_gas_equipment_epd_unit -Kitchen,51.16,361.7807576,302.6,767,Btu/hr.ft2 -Laundry,42.6,138.4291667,129.9,170,Btu/hr.ft2 -OR,17.4,23.223,23.87,23.87,Btu/hr.ft2 -Deli,8.52,8.5225,8.52,8.53,Btu/hr.ft2 -Bakery,8.53,8.5375,8.54,8.54,Btu/hr.ft2 -Deli/Bakery,6.25,6.25,6.25,6.25,Btu/hr.ft2 +kitchen,51.16,361.7807576,302.6,767,Btu/hr.ft2 +laundry,42.6,138.4291667,129.9,170,Btu/hr.ft2 +or,17.4,23.223,23.87,23.87,Btu/hr.ft2 +deli,8.52,8.5225,8.52,8.53,Btu/hr.ft2 +bakery,8.53,8.5375,8.54,8.54,Btu/hr.ft2 +deli/bakery,6.25,6.25,6.25,6.25,Btu/hr.ft2 diff --git a/data/openstudio_standards_data/database_files/level_2_natural_gas_equipment.json b/data/openstudio_standards_data/database_files/level_2_natural_gas_equipment.json new file mode 100644 index 0000000000..70ad2e43eb --- /dev/null +++ b/data/openstudio_standards_data/database_files/level_2_natural_gas_equipment.json @@ -0,0 +1,50 @@ +[ + { + "natural_gas_equipment_space_type_name": "kitchen", + "natural_gas_equipment_minimum_epd": 51.16, + "natural_gas_equipment_average_epd": 361.7807576, + "natural_gas_equipment_median_epd": 302.6, + "natural_gas_equipment_maximum_epd": 767, + "natural_gas_equipment_epd_unit": "Btu/hr.ft2" + }, + { + "natural_gas_equipment_space_type_name": "laundry", + "natural_gas_equipment_minimum_epd": 42.6, + "natural_gas_equipment_average_epd": 138.4291667, + "natural_gas_equipment_median_epd": 129.9, + "natural_gas_equipment_maximum_epd": 170, + "natural_gas_equipment_epd_unit": "Btu/hr.ft2" + }, + { + "natural_gas_equipment_space_type_name": "or", + "natural_gas_equipment_minimum_epd": 17.4, + "natural_gas_equipment_average_epd": 23.223, + "natural_gas_equipment_median_epd": 23.87, + "natural_gas_equipment_maximum_epd": 23.87, + "natural_gas_equipment_epd_unit": "Btu/hr.ft2" + }, + { + "natural_gas_equipment_space_type_name": "Deli/Bakery", + "natural_gas_equipment_minimum_epd": 8.52, + "natural_gas_equipment_average_epd": 8.5225, + "natural_gas_equipment_median_epd": 8.52, + "natural_gas_equipment_maximum_epd": 8.53, + "natural_gas_equipment_epd_unit": "Btu/hr.ft2" + }, + { + "natural_gas_equipment_space_type_name": "bakery", + "natural_gas_equipment_minimum_epd": 8.53, + "natural_gas_equipment_average_epd": 8.5375, + "natural_gas_equipment_median_epd": 8.54, + "natural_gas_equipment_maximum_epd": 8.54, + "natural_gas_equipment_epd_unit": "Btu/hr.ft2" + }, + { + "natural_gas_equipment_space_type_name": "deli/bakery", + "natural_gas_equipment_minimum_epd": 6.25, + "natural_gas_equipment_average_epd": 6.25, + "natural_gas_equipment_median_epd": 6.25, + "natural_gas_equipment_maximum_epd": 6.25, + "natural_gas_equipment_epd_unit": "Btu/hr.ft2" + } +] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.csv b/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.csv index 2d6b7b80f1..cee4562fa1 100644 --- a/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.csv +++ b/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.csv @@ -508,19 +508,19 @@ sports_and_entertainment_health_club_weight_rooms_ventilation,level_3_ventilatio sports_and_entertainment_spectator_areas_ventilation,level_3_ventilation_62_1_2004,55 sports_and_entertainment_stages_studios_ventilation,level_3_ventilation_62_1_2004,63 sports_and_entertainment_swimming_pool_deck_ventilation,level_3_ventilation_62_1_2004,56 -emergency_room_ventilation,level_3_ventilation_62_1_1999,83 -emergency_vehicle_garage_ventilation,level_3_ventilation_62_1_1999,83 -exam_treatment_ventilation,level_3_ventilation_62_1_1999,83 -imaging_ventilation,level_3_ventilation_62_1_1999,83 -interior_parking_ventilation,level_3_ventilation_62_1_1999,83 -food_preparation_ventilation,level_3_ventilation_62_1_1999,83 -laundry_washing_ventilation,level_3_ventilation_62_1_1999,83 -locker_room_ventilation,level_3_ventilation_62_1_1999,83 -lounge_breakroom_ventilation,level_3_ventilation_62_1_1999,83 -nursery_ventilation,level_3_ventilation_62_1_1999,83 -operating_room_ventilation,level_3_ventilation_62_1_1999,83 -patient_room_ventilation,level_3_ventilation_62_1_1999,83 -physical_therapy_ventilation,level_3_ventilation_62_1_1999,83 -recovery_ventilation,level_3_ventilation_62_1_1999,83 -restroom_ventilation,level_3_ventilation_62_1_1999,83 -vehicular_maintenance_ventilation,level_3_ventilation_62_1_1999,83 +emergency_room_ventilation,level_3_ventilation_62_1_1999,75 +emergency_vehicle_garage_ventilation,level_3_ventilation_62_1_1999,58 +exam_treatment_ventilation,level_3_ventilation_62_1_1999,75 +imaging_ventilation,level_3_ventilation_62_1_1999,75 +interior_parking_ventilation,level_3_ventilation_62_1_1999,58 +food_preparation_ventilation,level_3_ventilation_62_1_1999,9 +laundry_washing_ventilation,level_3_ventilation_62_1_1999,4 +locker_room_ventilation,level_3_ventilation_62_1_1999,26 +lounge_breakroom_ventilation,level_3_ventilation_62_1_1999,26 +nursery_ventilation,level_3_ventilation_62_1_1999,77 +operating_room_ventilation,level_3_ventilation_62_1_1999,76 +patient_room_ventilation,level_3_ventilation_62_1_1999,77 +physical_therapy_ventilation,level_3_ventilation_62_1_1999,79 +recovery_ventilation,level_3_ventilation_62_1_1999,77 +restroom_ventilation,level_3_ventilation_62_1_1999,25 +vehicular_maintenance_ventilation,level_3_ventilation_62_1_1999,10 diff --git a/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.json b/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.json index fe249d1293..354c87b3de 100644 --- a/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.json +++ b/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.json @@ -2547,81 +2547,81 @@ { "ventilation_space_type_name": "emergency_room_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", - "level_3_ventilation_definition_id": 83 + "level_3_ventilation_definition_id": 75 }, { "ventilation_space_type_name": "emergency_vehicle_garage_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", - "level_3_ventilation_definition_id": 83 + "level_3_ventilation_definition_id": 58 }, { "ventilation_space_type_name": "exam_treatment_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", - "level_3_ventilation_definition_id": 83 + "level_3_ventilation_definition_id": 75 }, { "ventilation_space_type_name": "imaging_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", - "level_3_ventilation_definition_id": 83 + "level_3_ventilation_definition_id": 75 }, { "ventilation_space_type_name": "interior_parking_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", - "level_3_ventilation_definition_id": 83 + "level_3_ventilation_definition_id": 58 }, { "ventilation_space_type_name": "food_preparation_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", - "level_3_ventilation_definition_id": 83 + "level_3_ventilation_definition_id": 9 }, { "ventilation_space_type_name": "laundry_washing_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", - "level_3_ventilation_definition_id": 83 + "level_3_ventilation_definition_id": 4 }, { "ventilation_space_type_name": "locker_room_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", - "level_3_ventilation_definition_id": 83 + "level_3_ventilation_definition_id": 26 }, { "ventilation_space_type_name": "lounge_breakroom_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", - "level_3_ventilation_definition_id": 83 + "level_3_ventilation_definition_id": 26 }, { "ventilation_space_type_name": "nursery_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", - "level_3_ventilation_definition_id": 83 + "level_3_ventilation_definition_id": 77 }, { "ventilation_space_type_name": "operating_room_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", - "level_3_ventilation_definition_id": 83 + "level_3_ventilation_definition_id": 76 }, { "ventilation_space_type_name": "patient_room_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", - "level_3_ventilation_definition_id": 83 + "level_3_ventilation_definition_id": 77 }, { "ventilation_space_type_name": "physical_therapy_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", - "level_3_ventilation_definition_id": 83 + "level_3_ventilation_definition_id": 79 }, { "ventilation_space_type_name": "recovery_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", - "level_3_ventilation_definition_id": 83 + "level_3_ventilation_definition_id": 77 }, { "ventilation_space_type_name": "restroom_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", - "level_3_ventilation_definition_id": 83 + "level_3_ventilation_definition_id": 25 }, { "ventilation_space_type_name": "vehicular_maintenance_ventilation", "level_3_ventilation_definition_table": "level_3_ventilation_62_1_1999", - "level_3_ventilation_definition_id": 83 + "level_3_ventilation_definition_id": 10 } ] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.csv b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.csv index 931c281a64..7effe8de98 100644 --- a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.csv +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.csv @@ -98,10 +98,10 @@ CS,Audience Seating Area,Sports Arena,0.43,W/ft2,4,,REQ,REQ,,ADD2,ADD2 SS,Transportation Facility,Airport Concourse,0.31,W/ft2,4,REQ,REQ,,ADD2,ADD2, SS,Transportation Facility,Baggage/carousel Area,0.46,W/ft2,4,REQ,REQ,,ADD2,ADD2, SS,Facility For The Visually Impaired,Chapel (used Primarily By Residents),1.06,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Sports Arena—playing Area,Class I Facility,2.47,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Sports Arena—playing Area,Class II Facility,1.96,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Sports Arena—playing Area,Class Iii Facility,1.7,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Sports Arena—playing Area,Class Iv Facility,1.13,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Sports Arena—playing Area,Class I Facility,2.47,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Sports Arena—playing Area,Class II Facility,1.96,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Sports Arena—playing Area,Class Iii Facility,1.7,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Sports Arena—playing Area,Class Iv Facility,1.13,W/ft2,4,REQ,REQ,,ADD2,ADD2, SS,Manufacturing Facility,Detailed Manufacturing Area,0.93,W/ft2,4,REQ,REQ,,ADD2,ADD2, SS,Retail Facilities,Dressing/Fitting Room,0.5,W/ft2,8,,REQ,,REQ,, SS,Manufacturing Facility,Equipment Room,0.65,W/ft2,6,REQ,REQ,,ADD2,ADD2, @@ -110,19 +110,19 @@ SS,Gymnasium/fitness Center,Exercise Area,0.5,W/ft2,4,REQ,REQ,,ADD2,ADD2, SS,Manufacturing Facility,Extra High Bay Area (>50 Ft Floor-to-ceiling Height),1.05,W/ft2,4,REQ,REQ,,ADD2,ADD2, SS,Religious Facility,Fellowship Hall,0.55,W/ft2,4,REQ,REQ,,ADD2,ADD2, SS,Automotive,General,0.56,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Convention Center—exhibit Space,General,0.88,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Dormitory—living Quarters,General,0.54,W/ft2,8,,,,,, -SS,Fire Station—sleeping Quarters,General,0.2,W/ft2,6,,,,,, -SS,Performing Arts Theater—dressing Room,General,0.36,W/ft2,6,REQ,REQ,,REQ,, -SS,Post Office—sorting Area,General,0.68,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, +SS,Convention Center—exhibit Space,General,0.88,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Dormitory—living Quarters,General,0.54,W/ft2,8,,,,,, +SS,Fire Station—sleeping Quarters,General,0.2,W/ft2,6,,,,,, +SS,Performing Arts Theater—dressing Room,General,0.36,W/ft2,6,REQ,REQ,,REQ,, +SS,Post Office—sorting Area,General,0.68,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, SS,Museum,General Exhibition Area,1.05,W/ft2,6,REQ,REQ,,ADD2,ADD2, SS,Manufacturing Facility,High Bay Area (25 To 50 Ft Floor-to-ceiling Height),0.75,W/ft2,4,REQ,REQ,,ADD2,ADD2, SS,Healthcare Facility,Imaging Room,1.06,W/ft2,6,,,,ADD2,ADD2, SS,Manufacturing Facility,Low Bay Area (<25 Ft Floor-to-ceiling Height),0.96,W/ft2,4,REQ,REQ,,ADD2,ADD2, SS,Retail Facilities,Mall Concourse,0.9,W/ft2,4,REQ,REQ,,ADD2,ADD2, SS,Healthcare Facility,Medical Supply Room,0.54,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, -SS,Warehouse—storage Area,"Medium To Bulky, Palletized Items",0.35,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, -SS,Healthcare Facility,Nurse’s Station,0.81,W/ft2,6,REQ,REQ,,ADD2,ADD2, +SS,Warehouse—storage Area,"Medium To Bulky, Palletized Items",0.35,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, +SS,Healthcare Facility,Nurse’s Station,0.81,W/ft2,6,REQ,REQ,,ADD2,ADD2, SS,Healthcare Facility,Nursery,1,W/ft2,6,REQ,REQ,,ADD2,ADD2, SS,Healthcare Facility,Operating Room,2.17,W/ft2,6,,,,ADD2,ADD2, SS,Healthcare Facility,Patient Room,0.62,W/ft2,6,REQ,REQ,,ADD2,ADD2, @@ -136,7 +136,7 @@ SS,Retail,Sales Additional (type 1),0.45,W/ft2,4,REQ,REQ,,ADD2,ADD2, SS,Retail,Sales Additional (type 2),0.45,W/ft2,4,REQ,REQ,,ADD2,ADD2, SS,Retail,Sales Additional (type 3),1.05,W/ft2,4,REQ,REQ,,ADD2,ADD2, SS,Retail,Sales Additional (type 4),1.88,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Warehouse—storage Area,"Smaller, Hand-carried Items",0.69,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, +SS,Warehouse—storage Area,"Smaller, Hand-carried Items",0.69,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, SS,Library,Stacks,1.2,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, SS,Transportation Facility,Terminal Ticket Counter,0.62,W/ft2,4,REQ,REQ,,ADD2,ADD2, SS,Religious Facility,Worship/Pulpit/Choir Area,1.53,W/ft2,4,REQ,REQ,,ADD2,ADD2, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2007.csv b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2007.csv index 117325f577..193bd79b61 100644 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2007.csv +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2007.csv @@ -51,7 +51,7 @@ Public Assembly Spaces,Courtrooms,5,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, Public Assembly Spaces,Legislative chambers,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, Public Assembly Spaces,Libraries,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, Public Assembly Spaces,Lobbies,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -Public Assembly Spaces,Museums (children�s),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, +Public Assembly Spaces,Museums (children�s),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, Public Assembly Spaces,Museums/galleries,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, Residential,Dwelling unit,5,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, Residential,Common corridors,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2007.json b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2007.json index afea4430f2..bc9d2636f2 100644 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2007.json +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2007.json @@ -677,7 +677,7 @@ }, { "ventilation_primary_space_type": "Public Assembly Spaces", - "ventilation_secondary_space_type": "Museums (children\u00c3\u00af\u00c2\u00bf\u00c2\u00bds)", + "ventilation_secondary_space_type": "Museums (children\u00c3\u0192\u00c2\u00af\u00c3\u201a\u00c2\u00bf\u00c3\u201a\u00c2\u00bds)", "ventilation_rate_occupant": 7.5, "ventilation_rate_occupant_unit": "cfm/person", "ventilation_rate_area": 0.12, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2010.csv b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2010.csv index c69650b920..f6b734428e 100644 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2010.csv +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2010.csv @@ -55,7 +55,7 @@ Public Assembly Spaces,Courtrooms,5,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, Public Assembly Spaces,Legislative chambers,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, Public Assembly Spaces,Libraries,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, Public Assembly Spaces,Lobbies,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -Public Assembly Spaces,Museums (children�s),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, +Public Assembly Spaces,Museums (children�s),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, Public Assembly Spaces,Museums/galleries,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, Residential,Dwelling unit,5,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, Residential,Common corridors,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2010.json b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2010.json index 2ac91560fe..5a31889f1a 100644 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2010.json +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2010.json @@ -729,7 +729,7 @@ }, { "ventilation_primary_space_type": "Public Assembly Spaces", - "ventilation_secondary_space_type": "Museums (children\u00c3\u00af\u00c2\u00bf\u00c2\u00bds)", + "ventilation_secondary_space_type": "Museums (children\u00c3\u0192\u00c2\u00af\u00c3\u201a\u00c2\u00bf\u00c3\u201a\u00c2\u00bds)", "ventilation_rate_occupant": 7.5, "ventilation_rate_occupant_unit": "cfm/person", "ventilation_rate_area": 0.12, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2013.csv b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2013.csv index 712c97498b..120109d38e 100644 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2013.csv +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2013.csv @@ -35,7 +35,7 @@ General,Occupiable storage rooms for liquids or gels,5,cfm/person,0.12,cfm/ft2,2 Miscellaneous Spaces,Bank vaults/safe deposit,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,2,, Miscellaneous Spaces,Banks or bank lobbies,7.5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,, Miscellaneous Spaces,Computer (not printing),5,cfm/person,0.06,cfm/ft2,4,ppl/1000 ft2,1,, -Miscellaneous Spaces,Freezer and refrigerated spaces (<50�F),10,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,2,, +Miscellaneous Spaces,Freezer and refrigerated spaces (<50�F),10,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,2,, Miscellaneous Spaces,General manufacturing (excludes heavy industrial and processes using chemicals),10,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,3,, Miscellaneous Spaces,Pharmacy (prep. area),5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, Miscellaneous Spaces,Photo studios,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, @@ -56,7 +56,7 @@ Public Assembly Spaces,Courtrooms,5,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, Public Assembly Spaces,Legislative chambers,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, Public Assembly Spaces,Libraries,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, Public Assembly Spaces,Lobbies,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -Public Assembly Spaces,Museums (children�s),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, +Public Assembly Spaces,Museums (children�s),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, Public Assembly Spaces,Museums/galleries,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, Residential,Dwelling unit,5,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, Residential,Common corridors,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2013.json b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2013.json index fe529c3029..7b03e3f74c 100644 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2013.json +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2013.json @@ -469,7 +469,7 @@ }, { "ventilation_primary_space_type": "Miscellaneous Spaces", - "ventilation_secondary_space_type": "Freezer and refrigerated spaces (<50\u00c3\u00af\u00c2\u00bf\u00c2\u00bdF)", + "ventilation_secondary_space_type": "Freezer and refrigerated spaces (<50\u00c3\u0192\u00c2\u00af\u00c3\u201a\u00c2\u00bf\u00c3\u201a\u00c2\u00bdF)", "ventilation_rate_occupant": 10, "ventilation_rate_occupant_unit": "cfm/person", "ventilation_rate_area": 0, @@ -742,7 +742,7 @@ }, { "ventilation_primary_space_type": "Public Assembly Spaces", - "ventilation_secondary_space_type": "Museums (children\u00c3\u00af\u00c2\u00bf\u00c2\u00bds)", + "ventilation_secondary_space_type": "Museums (children\u00c3\u0192\u00c2\u00af\u00c3\u201a\u00c2\u00bf\u00c3\u201a\u00c2\u00bds)", "ventilation_rate_occupant": 7.5, "ventilation_rate_occupant_unit": "cfm/person", "ventilation_rate_area": 0.12, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2016.csv b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2016.csv index 712c97498b..120109d38e 100644 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2016.csv +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2016.csv @@ -35,7 +35,7 @@ General,Occupiable storage rooms for liquids or gels,5,cfm/person,0.12,cfm/ft2,2 Miscellaneous Spaces,Bank vaults/safe deposit,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,2,, Miscellaneous Spaces,Banks or bank lobbies,7.5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,, Miscellaneous Spaces,Computer (not printing),5,cfm/person,0.06,cfm/ft2,4,ppl/1000 ft2,1,, -Miscellaneous Spaces,Freezer and refrigerated spaces (<50�F),10,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,2,, +Miscellaneous Spaces,Freezer and refrigerated spaces (<50�F),10,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,2,, Miscellaneous Spaces,General manufacturing (excludes heavy industrial and processes using chemicals),10,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,3,, Miscellaneous Spaces,Pharmacy (prep. area),5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, Miscellaneous Spaces,Photo studios,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, @@ -56,7 +56,7 @@ Public Assembly Spaces,Courtrooms,5,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, Public Assembly Spaces,Legislative chambers,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, Public Assembly Spaces,Libraries,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, Public Assembly Spaces,Lobbies,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -Public Assembly Spaces,Museums (children�s),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, +Public Assembly Spaces,Museums (children�s),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, Public Assembly Spaces,Museums/galleries,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, Residential,Dwelling unit,5,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, Residential,Common corridors,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2016.json b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2016.json index fe529c3029..7b03e3f74c 100644 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2016.json +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2016.json @@ -469,7 +469,7 @@ }, { "ventilation_primary_space_type": "Miscellaneous Spaces", - "ventilation_secondary_space_type": "Freezer and refrigerated spaces (<50\u00c3\u00af\u00c2\u00bf\u00c2\u00bdF)", + "ventilation_secondary_space_type": "Freezer and refrigerated spaces (<50\u00c3\u0192\u00c2\u00af\u00c3\u201a\u00c2\u00bf\u00c3\u201a\u00c2\u00bdF)", "ventilation_rate_occupant": 10, "ventilation_rate_occupant_unit": "cfm/person", "ventilation_rate_area": 0, @@ -742,7 +742,7 @@ }, { "ventilation_primary_space_type": "Public Assembly Spaces", - "ventilation_secondary_space_type": "Museums (children\u00c3\u00af\u00c2\u00bf\u00c2\u00bds)", + "ventilation_secondary_space_type": "Museums (children\u00c3\u0192\u00c2\u00af\u00c3\u201a\u00c2\u00bf\u00c3\u201a\u00c2\u00bds)", "ventilation_rate_occupant": 7.5, "ventilation_rate_occupant_unit": "cfm/person", "ventilation_rate_area": 0.12, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.csv b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.csv index cfa1e51ef3..03bb813e26 100644 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.csv +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.csv @@ -47,7 +47,7 @@ Food and Beverage Service,Restaurant dining rooms,7.5,cfm/person,0.18,cfm/ft2,70 Miscellaneous Spaces,Banks or bank lobbies,7.5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,yes, Miscellaneous Spaces,Bank vaults/safe deposit,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,2,yes, Miscellaneous Spaces,Computer (not printing),5,cfm/person,0.06,cfm/ft2,4,ppl/1000 ft2,1,yes, -Miscellaneous Spaces,Freezer and refrigerated spaces (<50�F [10�C]),10,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,2,, +Miscellaneous Spaces,Freezer and refrigerated spaces (<50�F [10�C]),10,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,2,, Miscellaneous Spaces,Manufacturing where hazardous materials are not used,10,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,2,, Miscellaneous Spaces,Manufacturing where hazardous materials are used (excludes heavy industrial and chemical processes),10,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,3,, Miscellaneous Spaces,Pharmacy (prep. area),5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.json b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.json index aa61220a0a..be9c84554f 100644 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.json +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.json @@ -625,7 +625,7 @@ }, { "ventilation_primary_space_type": "Miscellaneous Spaces", - "ventilation_secondary_space_type": "Freezer and refrigerated spaces (<50\u00c3\u00af\u00c2\u00bf\u00c2\u00bdF [10\u00c3\u00af\u00c2\u00bf\u00c2\u00bdC])", + "ventilation_secondary_space_type": "Freezer and refrigerated spaces (<50\u00c3\u0192\u00c2\u00af\u00c3\u201a\u00c2\u00bf\u00c3\u201a\u00c2\u00bdF [10\u00c3\u0192\u00c2\u00af\u00c3\u201a\u00c2\u00bf\u00c3\u201a\u00c2\u00bdC])", "ventilation_rate_occupant": 10, "ventilation_rate_occupant_unit": "cfm/person", "ventilation_rate_area": 0, diff --git a/data/openstudio_standards_data/database_files/support_schedules.csv b/data/openstudio_standards_data/database_files/support_schedules.csv index b5b7ac3689..20ad38159e 100644 --- a/data/openstudio_standards_data/database_files/support_schedules.csv +++ b/data/openstudio_standards_data/database_files/support_schedules.csv @@ -1,811 +1,811 @@ name,category,units,day_types,start_date,end_date,type,hr_1,hr_2,hr_3,hr_4,hr_5,hr_6,hr_7,hr_8,hr_9,hr_10,hr_11,hr_12,hr_13,hr_14,hr_15,hr_16,hr_17,hr_18,hr_19,hr_20,hr_21,hr_22,hr_23,hr_24,annotation -corridor_all_other,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.9,0.5,0,0,0, -corridor_all_other,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.9,0.51,0,0,0, -corridor_all_other,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.9,0.51,0,0,0, -corridor_all_other,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -corridor_all_other,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -corridor_all_other,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -corridor_all_other,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -corridor_all_other,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -corridor_all_other,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -dining_all_other,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0.25,0.9,0.9,0.75,0,0,0,0,0,0,0,0,0, -dining_all_other,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.25,0.25,0.25,0.9,0.9,0.5,0.25,0.25,0,0,0,0,0,0,0, -dining_all_other,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.25,0.25,0.25,0.9,0.9,0.5,0.25,0.25,0,0,0,0,0,0,0, -dining_all_other,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0,0,0, -dining_all_other,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, -dining_all_other,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, -dining_all_other,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.08,0.06,0.06,0.06,0.06,0.06,0.06, -dining_all_other,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.08,0.06,0.06,0.06,0.06,0.06,0.06, -dining_all_other,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.08,0.06,0.06,0.06,0.06,0.06,0.06, -electrical_mechanical,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0,0,0,0,0,0,0, -electrical_mechanical,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -electrical_mechanical,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -electrical_mechanical,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0,0,0,0,0,0,0, -electrical_mechanical,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -electrical_mechanical,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -electrical_mechanical,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.24,0.24,0.24,0.24,0.24,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25, -electrical_mechanical,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.24,0.24,0.24,0.24,0.24,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25, -electrical_mechanical,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.24,0.24,0.24,0.24,0.24,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25, -kitchen,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.5,0.25,0.25,0.9,0.9,0.75,0.25,0,0,0,0,0,0,0,0, -kitchen,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.25,0.25,0.25,0.9,0.75,0.5,0.25,0.25,0,0,0,0,0,0,0, -kitchen,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.25,0.25,0.25,0.9,0.75,0.5,0.25,0.25,0,0,0,0,0,0,0, -kitchen,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0,0, -kitchen,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, -kitchen,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, -kitchen,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.07,0.05,0.05,0.05,0.05,0.05,0.05, -kitchen,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.27,0.06,0.05,0.05,0.05,0.05,0.05, -kitchen,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.27,0.06,0.05,0.05,0.05,0.05,0.05, -laboratory,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -laboratory,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.05,0.125,0.375,0.45,0.45,0.25,0.25,0.45,0.45,0.25,0.25,0,0,0,0,0,0, -laboratory,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.05,0.125,0.625,0.9,0.9,0.75,0.75,0.9,0.825,0.25,0.25,0,0,0,0,0,0, -laboratory,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -laboratory,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0,0,0,0, -laboratory,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0,0,0,0,0,0, -laboratory,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, -laboratory,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.055,0.48,0.48,0.48,0.48,0.48,0.48,0.48,0.48,0.48,0.48,0.055,0.055,0.05,0.05,0.05,0.05, -laboratory,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.055,0.48,0.715,0.9,0.9,0.9,0.83,0.9,0.83,0.48,0.48,0.055,0.055,0.05,0.05,0.05,0.05, -lobby_all_other,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.25,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -lobby_all_other,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0,0,0,0,0,0, -lobby_all_other,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0,0,0,0,0,0, -lobby_all_other,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -lobby_all_other,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0,0,0,0,0,0, -lobby_all_other,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0,0,0,0,0,0, -lobby_all_other,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.53,0.9,0.9,0.05,0.05,0.05,0.05, -lobby_all_other,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.48,0.48,0.48,0.48,0.48,0.48,0.48,0.715,0.52,0.05,0.05,0.05,0.05,0.05,0.05, -lobby_all_other,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.48,0.48,0.48,0.48,0.48,0.48,0.48,0.715,0.52,0.05,0.05,0.05,0.05,0.05,0.05, -locker_room,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.5,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.75,0.25,0,0,0,0,0, -locker_room,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -locker_room,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -locker_room,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -locker_room,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -locker_room,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -locker_room,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -locker_room,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.06,0.05,0.05,0.05, -locker_room,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.06,0.05,0.05,0.05, -lounge_breakroom_all_other,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.25,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -lounge_breakroom_all_other,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, -lounge_breakroom_all_other,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, -lounge_breakroom_all_other,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -lounge_breakroom_all_other,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -lounge_breakroom_all_other,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -lounge_breakroom_all_other,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -lounge_breakroom_all_other,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.53,0.9,0.9,0.9,0.05,0.05,0.05, -lounge_breakroom_all_other,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.53,0.9,0.9,0.9,0.05,0.05,0.05, -office_enclosed_lte_250_sf,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.375,0.825,0.9,0.9,0.625,0.625,0.9,0.9,0.7,0.5,0,0,0,0,0,0, -office_enclosed_lte_250_sf,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -office_enclosed_lte_250_sf,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -office_enclosed_lte_250_sf,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -office_enclosed_lte_250_sf,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -office_enclosed_lte_250_sf,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -office_enclosed_lte_250_sf,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.7,0.05,0.05,0.05,0.05, -office_enclosed_lte_250_sf,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.4,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.4,0.15,0.05,0.05,0.05,0.05, -office_enclosed_lte_250_sf,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.4,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.4,0.15,0.05,0.05,0.05,0.05, -office_enclosed_gt_250_sf,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -office_enclosed_gt_250_sf,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -office_enclosed_gt_250_sf,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -office_enclosed_gt_250_sf,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -office_enclosed_gt_250_sf,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -office_enclosed_gt_250_sf,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -office_enclosed_gt_250_sf,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, -office_enclosed_gt_250_sf,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -office_enclosed_gt_250_sf,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -office_open,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.375,0.825,0.9,0.9,0.625,0.625,0.9,0.9,0.7,0.5,0,0,0,0,0,0, -office_open,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -office_open,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -office_open,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -office_open,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -office_open,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -office_open,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.825,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.825,0.7,0.05,0.05,0.05,0.05, -office_open,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -office_open,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -restroom_all_other,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.375,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.5,0.5,0,0,0, -restroom_all_other,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.375,0.5,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0.25,0,0,0, -restroom_all_other,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.375,0.5,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0.25,0,0,0, -restroom_all_other,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -restroom_all_other,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -restroom_all_other,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -restroom_all_other,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -restroom_all_other,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -restroom_all_other,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -stairwell,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.7,0.9,0.5,0,0,0, -stairwell,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.38,0,0,0, -stairwell,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.38,0,0,0, -stairwell,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -stairwell,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -stairwell,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -stairwell,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -stairwell,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -stairwell,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -storage_50_to_1000_sf_all_other,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.3,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -storage_50_to_1000_sf_all_other,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.1,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0,0,0,0,0,0, -storage_50_to_1000_sf_all_other,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.1,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0,0,0,0,0,0, -storage_50_to_1000_sf_all_other,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -storage_50_to_1000_sf_all_other,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -storage_50_to_1000_sf_all_other,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -storage_50_to_1000_sf_all_other,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -storage_50_to_1000_sf_all_other,Equipment,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -storage_50_to_1000_sf_all_other,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -storage_lt_50_sf_all_other,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.05,0.3,0.825,0.9,0.9,0.825,0.825,0.9,0.9,0.9,0.75,0.05,0.05,0,0,0,0, -storage_lt_50_sf_all_other,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.175,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0,0,0,0,0,0, -storage_lt_50_sf_all_other,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.175,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0,0,0,0,0,0, -storage_lt_50_sf_all_other,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0,0,0,0, -storage_lt_50_sf_all_other,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -storage_lt_50_sf_all_other,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -storage_lt_50_sf_all_other,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -storage_lt_50_sf_all_other,Equipment,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -storage_lt_50_sf_all_other,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -vehicular_maintenance,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.45,0.45,0.5,0.575,0.825,0.9,0.9,0.7,0.7,0.9,0.9,0.7,0.7,0.45,0.45,0.45,0,0,0, -vehicular_maintenance,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, -vehicular_maintenance,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, -vehicular_maintenance,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0.45,0,0,0, -vehicular_maintenance,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, -vehicular_maintenance,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, -vehicular_maintenance,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.045,0.045,0.045,0.045,0.045,0.47,0.47,0.47,0.47,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.47,0.47,0.47,0.47,0.045,0.045,0.045, -vehicular_maintenance,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.045,0.045,0.045,0.045,0.045,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.045,0.045,0.045, -vehicular_maintenance,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.045,0.045,0.045,0.045,0.045,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.045,0.045,0.045, -workshop,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -workshop,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, -workshop,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, -workshop,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -workshop,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -workshop,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -workshop,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.07,0.07,0.05,0.05,0.05,0.05, -workshop,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -workshop,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -atrium_first_three_floors,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0.25,0.25,0.25,0.25,0.25,0, -atrium_first_three_floors,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0.25,0.25,0.25,0.25,0.25,0, -atrium_first_three_floors,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0.25,0.25,0.25,0.25,0.25,0, -atrium_first_three_floors,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -atrium_first_three_floors,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -atrium_first_three_floors,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -atrium_first_three_floors,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -atrium_first_three_floors,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -atrium_first_three_floors,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_convention_center,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_convention_center,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_convention_center,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_convention_center,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_convention_center,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_convention_center,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_convention_center,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_convention_center,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_convention_center,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -classroom_lecture_training_all_other,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -classroom_lecture_training_all_other,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, -classroom_lecture_training_all_other,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, -classroom_lecture_training_all_other,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -classroom_lecture_training_all_other,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -classroom_lecture_training_all_other,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -classroom_lecture_training_all_other,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.07,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.05,0.05,0.05,0.05, -classroom_lecture_training_all_other,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, -classroom_lecture_training_all_other,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, -conference_meeting_multipurpose,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -conference_meeting_multipurpose,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, -conference_meeting_multipurpose,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, -conference_meeting_multipurpose,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -conference_meeting_multipurpose,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -conference_meeting_multipurpose,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -conference_meeting_multipurpose,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -conference_meeting_multipurpose,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, -conference_meeting_multipurpose,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.9,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, -exhibit_convention_center,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -exhibit_convention_center,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -exhibit_convention_center,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -exhibit_convention_center,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -exhibit_convention_center,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -exhibit_convention_center,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -exhibit_convention_center,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -exhibit_convention_center,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -exhibit_convention_center,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -gymnasium_exercise_area,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -gymnasium_exercise_area,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -gymnasium_exercise_area,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -gymnasium_exercise_area,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -gymnasium_exercise_area,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -gymnasium_exercise_area,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -gymnasium_exercise_area,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -gymnasium_exercise_area,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -gymnasium_exercise_area,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -gymnasium_playing_area,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0.25,0,0,0,0,0, -gymnasium_playing_area,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -gymnasium_playing_area,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -gymnasium_playing_area,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -gymnasium_playing_area,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -gymnasium_playing_area,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -gymnasium_playing_area,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.475,0.475,0.475,0.05,0.05,0.05, -gymnasium_playing_area,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.83,0.9,0.9,0.83,0.83,0.9,0.9,0.9,0.83,0.475,0.475,0.475,0.05,0.05,0.05, -gymnasium_playing_area,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.83,0.9,0.9,0.83,0.83,0.9,0.9,0.9,0.83,0.475,0.475,0.475,0.05,0.05,0.05, -laundry_washing,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0,0,0,0,0,0, -laundry_washing,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, -laundry_washing,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, -laundry_washing,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -laundry_washing,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, -laundry_washing,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, -laundry_washing,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.06,0.06,0.06,0.05,0.05,0.05,0.05, -laundry_washing,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.06,0.06,0.06,0.05,0.05,0.05,0.05, -laundry_washing,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.06,0.06,0.06,0.05,0.05,0.05,0.05, -lobby_elevator,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -lobby_elevator,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, -lobby_elevator,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, -lobby_elevator,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -lobby_elevator,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -lobby_elevator,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -lobby_elevator,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, -lobby_elevator,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -lobby_elevator,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -nurses_station,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -nurses_station,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -nurses_station,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -nurses_station,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -nurses_station,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -nurses_station,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -nurses_station,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, -nurses_station,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, -nurses_station,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, -post_office_sorting_area,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -post_office_sorting_area,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -post_office_sorting_area,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -post_office_sorting_area,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -post_office_sorting_area,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -post_office_sorting_area,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -post_office_sorting_area,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -post_office_sorting_area,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -post_office_sorting_area,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -sales,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -sales,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -sales,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -sales,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -sales,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -sales,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -sales,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -sales,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -sales,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -sports_arena_playing_area_class_iv,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -sports_arena_playing_area_class_iv,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -sports_arena_playing_area_class_iv,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -sports_arena_playing_area_class_iv,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -sports_arena_playing_area_class_iv,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -sports_arena_playing_area_class_iv,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -sports_arena_playing_area_class_iv,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -sports_arena_playing_area_class_iv,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -sports_arena_playing_area_class_iv,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -audience_seating_all_other,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.125,0.25,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.625,0.25,0,0,0,0,0, -audience_seating_all_other,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.625,0.9,0.9,0.825,0.75,0.9,0.825,0.45,0.375,0,0,0,0,0,0, -audience_seating_all_other,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.625,0.9,0.9,0.825,0.75,0.9,0.825,0.45,0.375,0,0,0,0,0,0, -audience_seating_all_other,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -audience_seating_all_other,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0,0,0,0,0,0, -audience_seating_all_other,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0,0,0,0,0,0, -audience_seating_all_other,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.475,0.05,0.05,0.05, -audience_seating_all_other,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.645,0.9,0.9,0.83,0.76,0.9,0.83,0.475,0.405,0.05,0.05,0.05,0.05,0.05,0.05, -audience_seating_all_other,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.83,0.9,0.9,0.83,0.83,0.9,0.9,0.9,0.405,0.05,0.05,0.05,0.05,0.05,0.05, -confinement_cells,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0.125,0.125,0.125,0.125,0.125,0.125,0.125,0.125,0.125,0,0,0,0,0.25,0.75, -confinement_cells,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, -confinement_cells,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, -confinement_cells,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0,0,0.9,0.45, -confinement_cells,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.45, -confinement_cells,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.45, -confinement_cells,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -confinement_cells,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -confinement_cells,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -courtroom,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -courtroom,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, -courtroom,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, -courtroom,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -courtroom,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -courtroom,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -courtroom,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.07,0.07,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.07,0.07,0.07,0.07,0.05,0.05,0.05, -courtroom,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.07,0.07,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.07,0.07,0.07,0.07,0.05,0.05,0.05, -courtroom,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.07,0.07,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.07,0.07,0.07,0.07,0.05,0.05,0.05, -judges_chambers,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -judges_chambers,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -judges_chambers,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -judges_chambers,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -judges_chambers,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -judges_chambers,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -judges_chambers,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -judges_chambers,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -judges_chambers,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -library_stacks,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -library_stacks,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0,0,0,0,0,0, -library_stacks,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0,0,0,0,0,0, -library_stacks,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -library_stacks,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.5,0.9,0.9,0.9,0.75,0.9,0.75,0,0,0,0,0,0,0,0, -library_stacks,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.5,0.9,0.9,0.9,0.75,0.9,0.75,0,0,0,0,0,0,0,0, -library_stacks,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -library_stacks,Equipment,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -library_stacks,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -storage_inactive,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.3,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.3,0,0,0,0,0,0, -storage_inactive,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0,0,0,0,0,0,0, -storage_inactive,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0,0,0,0,0,0,0, -storage_inactive,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -storage_inactive,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, -storage_inactive,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, -storage_inactive,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -storage_inactive,Equipment,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -storage_inactive,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -dining_bar_lounge_leisure,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, -dining_bar_lounge_leisure,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, -dining_bar_lounge_leisure,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, -dining_bar_lounge_leisure,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -dining_bar_lounge_leisure,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -dining_bar_lounge_leisure,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -dining_bar_lounge_leisure,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -dining_bar_lounge_leisure,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -dining_bar_lounge_leisure,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -dining_cafeteria_fast_food,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, -dining_cafeteria_fast_food,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, -dining_cafeteria_fast_food,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, -dining_cafeteria_fast_food,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -dining_cafeteria_fast_food,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -dining_cafeteria_fast_food,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -dining_cafeteria_fast_food,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -dining_cafeteria_fast_food,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -dining_cafeteria_fast_food,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -dining_family,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, -dining_family,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, -dining_family,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, -dining_family,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -dining_family,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -dining_family,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -dining_family,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -dining_family,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -dining_family,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -computer_room,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0.75,0.75,0.75,0.5,0.5,0, -computer_room,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0.75,0.75,0.75,0.5,0.5,0, -computer_room,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0.75,0.75,0.75,0.5,0.5,0, -computer_room,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -computer_room,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -computer_room,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -computer_room,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05, -computer_room,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05, -computer_room,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05, -dormitory_living_quarters,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75,0.9, -dormitory_living_quarters,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75,0.9, -dormitory_living_quarters,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75,0.9, -dormitory_living_quarters,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.5,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.25, -dormitory_living_quarters,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.5,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.25, -dormitory_living_quarters,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.5,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.25, -dormitory_living_quarters,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -dormitory_living_quarters,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -dormitory_living_quarters,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -audience_seating_exercise_center,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_exercise_center,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_exercise_center,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_exercise_center,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_exercise_center,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_exercise_center,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_exercise_center,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_exercise_center,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_exercise_center,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -exam_treatment,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -exam_treatment,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -exam_treatment,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -exam_treatment,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -exam_treatment,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -exam_treatment,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -exam_treatment,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, -exam_treatment,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -exam_treatment,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -library_reading,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, -library_reading,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0,0,0,0,0,0,0, -library_reading,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0,0,0,0,0,0,0, -library_reading,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -library_reading,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, -library_reading,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, -library_reading,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -library_reading,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -library_reading,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -emergency_vehicle_garage,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0,0,0,0,0,0,0, -emergency_vehicle_garage,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -emergency_vehicle_garage,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -emergency_vehicle_garage,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0,0,0,0,0,0,0, -emergency_vehicle_garage,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -emergency_vehicle_garage,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -emergency_vehicle_garage,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -emergency_vehicle_garage,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -emergency_vehicle_garage,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -firestation_sleeping_quarters,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, -firestation_sleeping_quarters,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, -firestation_sleeping_quarters,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, -firestation_sleeping_quarters,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0, -firestation_sleeping_quarters,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0, -firestation_sleeping_quarters,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0, -firestation_sleeping_quarters,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -firestation_sleeping_quarters,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -firestation_sleeping_quarters,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -parking_area_interior,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0.125,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.705,0.9,0.575,0.125,0,0,0, -parking_area_interior,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.58,0.46,0.58,0.75,0.75,0.705,0.46,0.46,0.5,0.25,0,0,0,0,0, -parking_area_interior,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.58,0.46,0.58,0.75,0.75,0.705,0.46,0.46,0.5,0.25,0,0,0,0,0, -parking_area_interior,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0,0,0, -parking_area_interior,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -parking_area_interior,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -parking_area_interior,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -parking_area_interior,Equipment,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -parking_area_interior,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -audience_seating_gymnasium,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_gymnasium,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_gymnasium,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_gymnasium,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_gymnasium,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_gymnasium,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_gymnasium,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_gymnasium,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_gymnasium,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -emergency_room,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.575,0.7,0.9,0.9,0.9,0.825,0.825,0.9,0.9,0.9,0.7,0.575,0.45,0.45,0,0,0, -emergency_room,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, -emergency_room,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, -emergency_room,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0,0,0, -emergency_room,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, -emergency_room,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, -emergency_room,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.475,0.475,0.475,0.05,0.05,0.05, -emergency_room,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.05,0.05,0.05, -emergency_room,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.05,0.05,0.05, -patient_room,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.575,0.7,0.9,0.9,0.9,0.825,0.825,0.9,0.9,0.9,0.7,0.575,0.45,0.45,0.45,0.45,0.45, -patient_room,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45, -patient_room,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45, -patient_room,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.15,0.8,0.9,0.9,0.9,0.9,0.9,0.9,0.8,0.6,0.6,0.8,0.9,0.45,0.45,0.45,0.35,0.15, -patient_room,Lighting,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.15,0.35,0.45,0.45,0.45,0.45,0.45,0.45,0.35,0.15,0.15,0.35,0.45,0.45,0.45,0.45,0.35,0.15, -patient_room,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.15,0.35,0.45,0.45,0.45,0.45,0.45,0.45,0.35,0.15,0.15,0.35,0.45,0.45,0.45,0.45,0.35,0.15, -patient_room,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.475,0.475,0.475,0.475,0.475,0.195, -patient_room,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.195, -patient_room,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.195, -pharmacy,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -pharmacy,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -pharmacy,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -pharmacy,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -pharmacy,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -pharmacy,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -pharmacy,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, -pharmacy,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -pharmacy,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -corridor_hospital,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -corridor_hospital,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -corridor_hospital,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -corridor_hospital,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -corridor_hospital,Lighting,,Sat,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -corridor_hospital,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -corridor_hospital,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -corridor_hospital,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -corridor_hospital,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -fellowship_hall_religious_facility,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -fellowship_hall_religious_facility,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, -fellowship_hall_religious_facility,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, -fellowship_hall_religious_facility,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -fellowship_hall_religious_facility,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, -fellowship_hall_religious_facility,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, -fellowship_hall_religious_facility,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -fellowship_hall_religious_facility,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.05,0.05,0.05, -fellowship_hall_religious_facility,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.05,0.05,0.05, -lounge_breakroom_healthcare_facility,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -lounge_breakroom_healthcare_facility,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -lounge_breakroom_healthcare_facility,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -lounge_breakroom_healthcare_facility,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -lounge_breakroom_healthcare_facility,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -lounge_breakroom_healthcare_facility,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -lounge_breakroom_healthcare_facility,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, -lounge_breakroom_healthcare_facility,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, -lounge_breakroom_healthcare_facility,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, -operating_room,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -operating_room,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -operating_room,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -operating_room,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.18,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.58,0.45,0.18, -operating_room,Lighting,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.18,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.58,0.45,0.18, -operating_room,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.18,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.58,0.45,0.18, -operating_room,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -operating_room,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -operating_room,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -physical_therapy,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -physical_therapy,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -physical_therapy,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -physical_therapy,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -physical_therapy,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -physical_therapy,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -physical_therapy,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, -physical_therapy,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, -physical_therapy,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, -storage_50_to_1000_sf_hospital,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, -storage_50_to_1000_sf_hospital,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, -storage_50_to_1000_sf_hospital,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, -storage_50_to_1000_sf_hospital,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, -storage_50_to_1000_sf_hospital,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, -storage_50_to_1000_sf_hospital,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, -storage_50_to_1000_sf_hospital,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -storage_50_to_1000_sf_hospital,Equipment,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -storage_50_to_1000_sf_hospital,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -storage_lt_50_sf_hospital,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, -storage_lt_50_sf_hospital,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, -storage_lt_50_sf_hospital,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, -storage_lt_50_sf_hospital,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, -storage_lt_50_sf_hospital,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, -storage_lt_50_sf_hospital,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, -storage_lt_50_sf_hospital,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -storage_lt_50_sf_hospital,Equipment,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -storage_lt_50_sf_hospital,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -guest_room,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75,0.9, -guest_room,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75,0.9, -guest_room,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75,0.9, -guest_room,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9, -guest_room,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9, -guest_room,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9, -guest_room,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -guest_room,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -guest_room,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -lobby_hotel,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.3, -lobby_hotel,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.3, -lobby_hotel,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.3, -lobby_hotel,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -lobby_hotel,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -lobby_hotel,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -lobby_hotel,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -lobby_hotel,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -lobby_hotel,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -library_cataloging,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -library_cataloging,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -library_cataloging,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -library_cataloging,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -library_cataloging,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -library_cataloging,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -library_cataloging,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -library_cataloging,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -library_cataloging,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -museum_exhibit_area,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.375,0.45,0.45,0.375,0.375,0.45,0.45,0.7,0.5,0.125,0,0,0,0,0, -museum_exhibit_area,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.375,0.45,0.45,0.375,0.375,0.45,0.45,0.7,0.5,0.125,0,0,0,0,0, -museum_exhibit_area,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.375,0.45,0.45,0.375,0.375,0.45,0.45,0.7,0.5,0.125,0,0,0,0,0, -museum_exhibit_area,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45, -museum_exhibit_area,Lighting,,Sat,1-Jan,31-Dec,Hourly,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45, -museum_exhibit_area,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45, -museum_exhibit_area,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.055,0.055,0.055,0.055,0.055,0.05, -museum_exhibit_area,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.055,0.055,0.055,0.055,0.055,0.05, -museum_exhibit_area,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.055,0.055,0.055,0.055,0.055,0.05, -corridor_manufacturing_facility,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -corridor_manufacturing_facility,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -corridor_manufacturing_facility,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -corridor_manufacturing_facility,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -corridor_manufacturing_facility,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -corridor_manufacturing_facility,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -corridor_manufacturing_facility,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.04,0.04,0.04,0.04,0.04,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.04,0.04,0.04, -corridor_manufacturing_facility,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.04,0.04,0.04,0.04,0.04,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.04,0.04,0.04, -corridor_manufacturing_facility,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.04,0.04,0.04,0.04,0.04,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.04,0.04,0.04, -manufacturing_equipment_room,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -manufacturing_equipment_room,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -manufacturing_equipment_room,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -manufacturing_equipment_room,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -manufacturing_equipment_room,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -manufacturing_equipment_room,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -manufacturing_equipment_room,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -manufacturing_equipment_room,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -manufacturing_equipment_room,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -manufacturing_low_bay,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -manufacturing_low_bay,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -manufacturing_low_bay,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -manufacturing_low_bay,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -manufacturing_low_bay,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -manufacturing_low_bay,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -manufacturing_low_bay,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -manufacturing_low_bay,Equipment,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -manufacturing_low_bay,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -performing_arts_dressing_room,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.825,0,0,0,0,0,0, -performing_arts_dressing_room,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0,0,0,0,0,0, -performing_arts_dressing_room,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0,0,0,0,0,0, -performing_arts_dressing_room,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -performing_arts_dressing_room,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0,0,0,0,0,0, -performing_arts_dressing_room,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0,0,0,0,0,0, -performing_arts_dressing_room,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.045,0.045,0.045,0.045,0.055,0.055,0.055,0.055,0.48,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.475,0.475,0.475,0.045,0.045,0.045, -performing_arts_dressing_room,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.045,0.045,0.045,0.045,0.055,0.055,0.055,0.055,0.48,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.48,0.055,0.055,0.055,0.045,0.045,0.045, -performing_arts_dressing_room,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.045,0.045,0.045,0.045,0.045,0.045,0.045,0.045,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.48,0.055,0.055,0.055,0.045,0.045,0.045, -audience_seating_auditorium,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_auditorium,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_auditorium,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_auditorium,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_auditorium,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_auditorium,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_auditorium,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_auditorium,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_auditorium,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_motion_picture_theater,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_motion_picture_theater,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_motion_picture_theater,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_motion_picture_theater,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_motion_picture_theater,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_motion_picture_theater,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_motion_picture_theater,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_motion_picture_theater,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_motion_picture_theater,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -lobby_motion_picture_theater,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -lobby_motion_picture_theater,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -lobby_motion_picture_theater,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -lobby_motion_picture_theater,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -lobby_motion_picture_theater,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -lobby_motion_picture_theater,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -lobby_motion_picture_theater,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -lobby_motion_picture_theater,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -lobby_motion_picture_theater,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -dwelling_unit,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, -dwelling_unit,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, -dwelling_unit,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, -dwelling_unit,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0,0,0,0,0,0,0,0,0,0.2,0.2,0.2,0.2,0, -dwelling_unit,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0,0,0,0,0,0,0,0,0,0.2,0.2,0.2,0.2,0, -dwelling_unit,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0,0,0,0,0,0,0,0,0,0.2,0.2,0.2,0.2,0, -dwelling_unit,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -dwelling_unit,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -dwelling_unit,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -museum_restoration,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -museum_restoration,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -museum_restoration,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -museum_restoration,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -museum_restoration,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -museum_restoration,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -museum_restoration,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -museum_restoration,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -museum_restoration,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -banking_activity,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -banking_activity,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -banking_activity,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -banking_activity,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -banking_activity,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -banking_activity,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -banking_activity,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, -banking_activity,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -banking_activity,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -warehouse_fine_storage,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.45,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.45,0,0,0,0,0,0, -warehouse_fine_storage,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.45,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.45,0,0,0,0,0,0, -warehouse_fine_storage,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.45,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.45,0,0,0,0,0,0, -warehouse_fine_storage,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.45,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.45,0,0,0,0,0,0, -warehouse_fine_storage,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.45,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.45,0,0,0,0,0,0, -warehouse_fine_storage,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.45,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.45,0,0,0,0,0,0, -warehouse_fine_storage,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -warehouse_fine_storage,Equipment,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -warehouse_fine_storage,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -classroom_lecture_training_penitentiary,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -classroom_lecture_training_penitentiary,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -classroom_lecture_training_penitentiary,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -classroom_lecture_training_penitentiary,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -classroom_lecture_training_penitentiary,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -classroom_lecture_training_penitentiary,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -classroom_lecture_training_penitentiary,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.04,0.04,0.04,0.04,0.04,0.04,0.04, -classroom_lecture_training_penitentiary,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04, -classroom_lecture_training_penitentiary,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04, -dining_penitentiary,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0.25,0.9,0.9,0.25,0,0.25,0.9,0.9,0.5,0,0,0.5,0.9,0.9,0.5,0,0,0, -dining_penitentiary,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0.25,0.9,0.9,0.25,0,0.25,0.9,0.9,0.5,0,0,0.5,0.9,0.9,0.5,0,0,0, -dining_penitentiary,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0.25,0.9,0.9,0.25,0,0.25,0.9,0.9,0.5,0,0,0.5,0.9,0.9,0.5,0,0,0, -dining_penitentiary,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0,0.9,0.9,0.9,0.9,0,0,0.9,0.9,0.9,0.9,0,0,0, -dining_penitentiary,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0,0.9,0.9,0.9,0.9,0,0,0.9,0.9,0.9,0.9,0,0,0, -dining_penitentiary,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0,0.9,0.9,0.9,0.9,0,0,0.9,0.9,0.9,0.9,0,0,0, -dining_penitentiary,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.9,0.9,0.3,0.07,0.3,0.9,0.9,0.54,0.07,0.07,0.54,0.9,0.9,0.54,0.07,0.07,0.07, -dining_penitentiary,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.9,0.9,0.3,0.07,0.3,0.9,0.9,0.54,0.07,0.07,0.54,0.9,0.9,0.54,0.07,0.07,0.07, -dining_penitentiary,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.9,0.9,0.3,0.07,0.3,0.9,0.9,0.54,0.07,0.07,0.54,0.9,0.9,0.54,0.07,0.07,0.07, -audience_seating_performing_arts_theater,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_performing_arts_theater,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_performing_arts_theater,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_performing_arts_theater,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_performing_arts_theater,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_performing_arts_theater,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_performing_arts_theater,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_performing_arts_theater,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_performing_arts_theater,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -lobby_performing_arts_theater,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -lobby_performing_arts_theater,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -lobby_performing_arts_theater,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -lobby_performing_arts_theater,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -lobby_performing_arts_theater,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -lobby_performing_arts_theater,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -lobby_performing_arts_theater,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -lobby_performing_arts_theater,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -lobby_performing_arts_theater,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -audience_seating_religious_facility,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -audience_seating_religious_facility,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -audience_seating_religious_facility,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -audience_seating_religious_facility,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -audience_seating_religious_facility,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -audience_seating_religious_facility,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -audience_seating_religious_facility,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -audience_seating_religious_facility,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -audience_seating_religious_facility,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -worship_pulpit_choir_area,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -worship_pulpit_choir_area,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -worship_pulpit_choir_area,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -worship_pulpit_choir_area,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -worship_pulpit_choir_area,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -worship_pulpit_choir_area,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -worship_pulpit_choir_area,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -worship_pulpit_choir_area,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -worship_pulpit_choir_area,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -classroom_lecture_training_preschool_to_12th,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -classroom_lecture_training_preschool_to_12th,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -classroom_lecture_training_preschool_to_12th,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -classroom_lecture_training_preschool_to_12th,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -classroom_lecture_training_preschool_to_12th,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -classroom_lecture_training_preschool_to_12th,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -classroom_lecture_training_preschool_to_12th,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -classroom_lecture_training_preschool_to_12th,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -classroom_lecture_training_preschool_to_12th,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -sports_arena_playing_area_class_ii,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.125,0.25,0.9,0.9,0.9,0.825,0.825,0.9,0.9,0.9,0.7,0.575,0.45,0.45,0,0,0, -sports_arena_playing_area_class_ii,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.825,0.9,0.9,0.825,0.825,0.9,0.9,0.9,0.825,0.45,0.45,0.45,0,0,0, -sports_arena_playing_area_class_ii,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.825,0.9,0.9,0.825,0.825,0.9,0.9,0.9,0.825,0.45,0.45,0.45,0,0,0, -sports_arena_playing_area_class_ii,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0,0,0, -sports_arena_playing_area_class_ii,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0.45,0,0,0, -sports_arena_playing_area_class_ii,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0.45,0,0,0, -sports_arena_playing_area_class_ii,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.475,0.05,0.05,0.05, -sports_arena_playing_area_class_ii,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.83,0.9,0.9,0.83,0.83,0.9,0.9,0.9,0.83,0.475,0.475,0.475,0.05,0.05,0.05, -sports_arena_playing_area_class_ii,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.83,0.9,0.9,0.83,0.83,0.9,0.9,0.9,0.83,0.475,0.475,0.475,0.05,0.05,0.05, -audience_seating_sports_arena,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_sports_arena,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_sports_arena,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_sports_arena,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_sports_arena,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_sports_arena,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_sports_arena,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_sports_arena,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_sports_arena,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -airport_concourse,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0.25,0.25,0.25,0.25,0.25, -airport_concourse,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0.25,0.25,0.25,0.25,0.25, -airport_concourse,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0.25,0.25,0.25,0.25,0.25, -airport_concourse,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -airport_concourse,Lighting,,Sat,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -airport_concourse,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -airport_concourse,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -airport_concourse,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -airport_concourse,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -atrium_lt_20_ft_height,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_lt_20_ft_height,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_lt_20_ft_height,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_lt_20_ft_height,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_lt_20_ft_height,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_lt_20_ft_height,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_lt_20_ft_height,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -atrium_lt_20_ft_height,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -atrium_lt_20_ft_height,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -atrium_gt_40_ft_height,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_gt_40_ft_height,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_gt_40_ft_height,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_gt_40_ft_height,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_gt_40_ft_height,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_gt_40_ft_height,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_gt_40_ft_height,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -atrium_gt_40_ft_height,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -atrium_gt_40_ft_height,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -atrium_gte_20_ft_and_lte_40_ft_in_height,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_gte_20_ft_and_lte_40_ft_in_height,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_gte_20_ft_and_lte_40_ft_in_height,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_gte_20_ft_and_lte_40_ft_in_height,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_gte_20_ft_and_lte_40_ft_in_height,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_gte_20_ft_and_lte_40_ft_in_height,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_gte_20_ft_and_lte_40_ft_in_height,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -atrium_gte_20_ft_and_lte_40_ft_in_height,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -atrium_gte_20_ft_and_lte_40_ft_in_height,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -baggage_carousel,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0.25,0.25,0.25,0.25,0.25, -baggage_carousel,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0.25,0.25,0.25,0.25,0.25, -baggage_carousel,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0.25,0.25,0.25,0.25,0.25, -baggage_carousel,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -baggage_carousel,Lighting,,Sat,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -baggage_carousel,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -baggage_carousel,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -baggage_carousel,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -baggage_carousel,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -seating_area_general,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25,0.25, -seating_area_general,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25,0.25, -seating_area_general,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25,0.25, -seating_area_general,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -seating_area_general,Lighting,,Sat,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -seating_area_general,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -seating_area_general,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -seating_area_general,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -seating_area_general,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -transportation_ticket_counter,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -transportation_ticket_counter,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -transportation_ticket_counter,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -transportation_ticket_counter,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -transportation_ticket_counter,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -transportation_ticket_counter,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -transportation_ticket_counter,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25,0.25,0.25, -transportation_ticket_counter,Equipment,,Sat,1-Jan,31-Dec,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25,0.25,0.25, -transportation_ticket_counter,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25,0.25,0.25, -warehouse_bulk_storage,Occupancy,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -warehouse_bulk_storage,Occupancy,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -warehouse_bulk_storage,Occupancy,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -warehouse_bulk_storage,Lighting,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -warehouse_bulk_storage,Lighting,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -warehouse_bulk_storage,Lighting,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -warehouse_bulk_storage,Equipment,,Default|SmrDsn|Wkdy,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -warehouse_bulk_storage,Equipment,,Sat,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -warehouse_bulk_storage,Equipment,,WntrDsn|Hol|Sun,1-Jan,31-Dec,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +corridor_all_other,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.9,0.5,0,0,0, +corridor_all_other,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.9,0.51,0,0,0, +corridor_all_other,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.9,0.51,0,0,0, +corridor_all_other,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +corridor_all_other,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +corridor_all_other,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +corridor_all_other,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +corridor_all_other,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +corridor_all_other,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +dining_all_other,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0.25,0.9,0.9,0.75,0,0,0,0,0,0,0,0,0, +dining_all_other,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.25,0.25,0.25,0.9,0.9,0.5,0.25,0.25,0,0,0,0,0,0,0, +dining_all_other,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.25,0.25,0.25,0.9,0.9,0.5,0.25,0.25,0,0,0,0,0,0,0, +dining_all_other,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0,0,0, +dining_all_other,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, +dining_all_other,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, +dining_all_other,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.08,0.06,0.06,0.06,0.06,0.06,0.06, +dining_all_other,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.08,0.06,0.06,0.06,0.06,0.06,0.06, +dining_all_other,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.08,0.06,0.06,0.06,0.06,0.06,0.06, +electrical_mechanical,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0,0,0,0,0,0,0, +electrical_mechanical,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +electrical_mechanical,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +electrical_mechanical,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0,0,0,0,0,0,0, +electrical_mechanical,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +electrical_mechanical,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +electrical_mechanical,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.24,0.24,0.24,0.24,0.24,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25, +electrical_mechanical,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.24,0.24,0.24,0.24,0.24,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25, +electrical_mechanical,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.24,0.24,0.24,0.24,0.24,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25, +kitchen,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.5,0.25,0.25,0.9,0.9,0.75,0.25,0,0,0,0,0,0,0,0, +kitchen,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.25,0.25,0.25,0.9,0.75,0.5,0.25,0.25,0,0,0,0,0,0,0, +kitchen,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.25,0.25,0.25,0.9,0.75,0.5,0.25,0.25,0,0,0,0,0,0,0, +kitchen,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0,0, +kitchen,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, +kitchen,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, +kitchen,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.07,0.05,0.05,0.05,0.05,0.05,0.05, +kitchen,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.27,0.06,0.05,0.05,0.05,0.05,0.05, +kitchen,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.27,0.06,0.05,0.05,0.05,0.05,0.05, +laboratory,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +laboratory,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.05,0.125,0.375,0.45,0.45,0.25,0.25,0.45,0.45,0.25,0.25,0,0,0,0,0,0, +laboratory,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.05,0.125,0.625,0.9,0.9,0.75,0.75,0.9,0.825,0.25,0.25,0,0,0,0,0,0, +laboratory,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +laboratory,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0,0,0,0, +laboratory,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0,0,0,0,0,0, +laboratory,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, +laboratory,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.055,0.48,0.48,0.48,0.48,0.48,0.48,0.48,0.48,0.48,0.48,0.055,0.055,0.05,0.05,0.05,0.05, +laboratory,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.055,0.48,0.715,0.9,0.9,0.9,0.83,0.9,0.83,0.48,0.48,0.055,0.055,0.05,0.05,0.05,0.05, +lobby_all_other,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.25,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +lobby_all_other,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0,0,0,0,0,0, +lobby_all_other,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0,0,0,0,0,0, +lobby_all_other,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +lobby_all_other,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0,0,0,0,0,0, +lobby_all_other,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0,0,0,0,0,0, +lobby_all_other,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.53,0.9,0.9,0.05,0.05,0.05,0.05, +lobby_all_other,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.48,0.48,0.48,0.48,0.48,0.48,0.48,0.715,0.52,0.05,0.05,0.05,0.05,0.05,0.05, +lobby_all_other,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.48,0.48,0.48,0.48,0.48,0.48,0.48,0.715,0.52,0.05,0.05,0.05,0.05,0.05,0.05, +locker_room,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.5,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.75,0.25,0,0,0,0,0, +locker_room,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +locker_room,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +locker_room,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +locker_room,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +locker_room,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +locker_room,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +locker_room,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.06,0.05,0.05,0.05, +locker_room,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.06,0.05,0.05,0.05, +lounge_breakroom_all_other,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.25,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +lounge_breakroom_all_other,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, +lounge_breakroom_all_other,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, +lounge_breakroom_all_other,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +lounge_breakroom_all_other,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +lounge_breakroom_all_other,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +lounge_breakroom_all_other,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +lounge_breakroom_all_other,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.53,0.9,0.9,0.9,0.05,0.05,0.05, +lounge_breakroom_all_other,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.53,0.9,0.9,0.9,0.05,0.05,0.05, +office_enclosed_lte_250_sf,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.375,0.825,0.9,0.9,0.625,0.625,0.9,0.9,0.7,0.5,0,0,0,0,0,0, +office_enclosed_lte_250_sf,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +office_enclosed_lte_250_sf,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +office_enclosed_lte_250_sf,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +office_enclosed_lte_250_sf,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +office_enclosed_lte_250_sf,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +office_enclosed_lte_250_sf,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.7,0.05,0.05,0.05,0.05, +office_enclosed_lte_250_sf,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.4,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.4,0.15,0.05,0.05,0.05,0.05, +office_enclosed_lte_250_sf,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.4,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.4,0.15,0.05,0.05,0.05,0.05, +office_enclosed_gt_250_sf,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +office_enclosed_gt_250_sf,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +office_enclosed_gt_250_sf,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +office_enclosed_gt_250_sf,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +office_enclosed_gt_250_sf,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +office_enclosed_gt_250_sf,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +office_enclosed_gt_250_sf,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, +office_enclosed_gt_250_sf,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +office_enclosed_gt_250_sf,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +office_open,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.375,0.825,0.9,0.9,0.625,0.625,0.9,0.9,0.7,0.5,0,0,0,0,0,0, +office_open,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +office_open,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +office_open,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +office_open,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +office_open,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +office_open,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.825,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.825,0.7,0.05,0.05,0.05,0.05, +office_open,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +office_open,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +restroom_all_other,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.375,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.5,0.5,0,0,0, +restroom_all_other,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.375,0.5,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0.25,0,0,0, +restroom_all_other,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.375,0.5,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0.25,0,0,0, +restroom_all_other,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +restroom_all_other,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +restroom_all_other,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +restroom_all_other,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +restroom_all_other,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +restroom_all_other,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +stairwell,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.7,0.9,0.5,0,0,0, +stairwell,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.38,0,0,0, +stairwell,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.38,0,0,0, +stairwell,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +stairwell,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +stairwell,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +stairwell,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +stairwell,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +stairwell,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +storage_50_to_1000_sf_all_other,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.3,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +storage_50_to_1000_sf_all_other,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.1,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0,0,0,0,0,0, +storage_50_to_1000_sf_all_other,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.1,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0,0,0,0,0,0, +storage_50_to_1000_sf_all_other,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +storage_50_to_1000_sf_all_other,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +storage_50_to_1000_sf_all_other,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +storage_50_to_1000_sf_all_other,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +storage_50_to_1000_sf_all_other,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +storage_50_to_1000_sf_all_other,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +storage_lt_50_sf_all_other,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.05,0.3,0.825,0.9,0.9,0.825,0.825,0.9,0.9,0.9,0.75,0.05,0.05,0,0,0,0, +storage_lt_50_sf_all_other,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.175,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0,0,0,0,0,0, +storage_lt_50_sf_all_other,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.175,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0,0,0,0,0,0, +storage_lt_50_sf_all_other,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0,0,0,0, +storage_lt_50_sf_all_other,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +storage_lt_50_sf_all_other,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +storage_lt_50_sf_all_other,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +storage_lt_50_sf_all_other,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +storage_lt_50_sf_all_other,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +vehicular_maintenance,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.45,0.45,0.5,0.575,0.825,0.9,0.9,0.7,0.7,0.9,0.9,0.7,0.7,0.45,0.45,0.45,0,0,0, +vehicular_maintenance,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, +vehicular_maintenance,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, +vehicular_maintenance,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0.45,0,0,0, +vehicular_maintenance,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, +vehicular_maintenance,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, +vehicular_maintenance,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.045,0.045,0.045,0.045,0.045,0.47,0.47,0.47,0.47,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.47,0.47,0.47,0.47,0.045,0.045,0.045, +vehicular_maintenance,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.045,0.045,0.045,0.045,0.045,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.045,0.045,0.045, +vehicular_maintenance,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.045,0.045,0.045,0.045,0.045,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.045,0.045,0.045, +workshop,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +workshop,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, +workshop,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, +workshop,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +workshop,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +workshop,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +workshop,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.07,0.07,0.05,0.05,0.05,0.05, +workshop,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +workshop,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +atrium_first_three_floors,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0.25,0.25,0.25,0.25,0.25,0, +atrium_first_three_floors,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0.25,0.25,0.25,0.25,0.25,0, +atrium_first_three_floors,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0.25,0.25,0.25,0.25,0.25,0, +atrium_first_three_floors,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +atrium_first_three_floors,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +atrium_first_three_floors,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +atrium_first_three_floors,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +atrium_first_three_floors,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +atrium_first_three_floors,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_convention_center,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_convention_center,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_convention_center,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_convention_center,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_convention_center,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_convention_center,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_convention_center,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_convention_center,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_convention_center,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +classroom_lecture_training_all_other,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +classroom_lecture_training_all_other,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, +classroom_lecture_training_all_other,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, +classroom_lecture_training_all_other,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +classroom_lecture_training_all_other,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +classroom_lecture_training_all_other,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +classroom_lecture_training_all_other,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.07,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.05,0.05,0.05,0.05, +classroom_lecture_training_all_other,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, +classroom_lecture_training_all_other,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, +conference_meeting_multipurpose,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +conference_meeting_multipurpose,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, +conference_meeting_multipurpose,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, +conference_meeting_multipurpose,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +conference_meeting_multipurpose,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +conference_meeting_multipurpose,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +conference_meeting_multipurpose,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +conference_meeting_multipurpose,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, +conference_meeting_multipurpose,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.9,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, +exhibit_convention_center,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +exhibit_convention_center,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +exhibit_convention_center,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +exhibit_convention_center,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +exhibit_convention_center,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +exhibit_convention_center,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +exhibit_convention_center,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +exhibit_convention_center,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +exhibit_convention_center,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +gymnasium_exercise_area,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +gymnasium_exercise_area,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +gymnasium_exercise_area,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +gymnasium_exercise_area,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +gymnasium_exercise_area,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +gymnasium_exercise_area,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +gymnasium_exercise_area,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +gymnasium_exercise_area,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +gymnasium_exercise_area,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +gymnasium_playing_area,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0.25,0,0,0,0,0, +gymnasium_playing_area,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +gymnasium_playing_area,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +gymnasium_playing_area,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +gymnasium_playing_area,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +gymnasium_playing_area,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +gymnasium_playing_area,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.475,0.475,0.475,0.05,0.05,0.05, +gymnasium_playing_area,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.83,0.9,0.9,0.83,0.83,0.9,0.9,0.9,0.83,0.475,0.475,0.475,0.05,0.05,0.05, +gymnasium_playing_area,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.83,0.9,0.9,0.83,0.83,0.9,0.9,0.9,0.83,0.475,0.475,0.475,0.05,0.05,0.05, +laundry_washing,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0,0,0,0,0,0, +laundry_washing,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, +laundry_washing,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, +laundry_washing,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +laundry_washing,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, +laundry_washing,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, +laundry_washing,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.06,0.06,0.06,0.05,0.05,0.05,0.05, +laundry_washing,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.06,0.06,0.06,0.05,0.05,0.05,0.05, +laundry_washing,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.06,0.06,0.06,0.05,0.05,0.05,0.05, +lobby_elevator,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +lobby_elevator,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, +lobby_elevator,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, +lobby_elevator,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +lobby_elevator,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +lobby_elevator,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +lobby_elevator,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, +lobby_elevator,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +lobby_elevator,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +nurses_station,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +nurses_station,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +nurses_station,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +nurses_station,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +nurses_station,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +nurses_station,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +nurses_station,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, +nurses_station,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, +nurses_station,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, +post_office_sorting_area,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +post_office_sorting_area,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +post_office_sorting_area,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +post_office_sorting_area,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +post_office_sorting_area,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +post_office_sorting_area,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +post_office_sorting_area,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +post_office_sorting_area,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +post_office_sorting_area,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +sales,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +sales,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +sales,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +sales,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +sales,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +sales,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +sales,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +sales,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +sales,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +sports_arena_playing_area_class_iv,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +sports_arena_playing_area_class_iv,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +sports_arena_playing_area_class_iv,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +sports_arena_playing_area_class_iv,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +sports_arena_playing_area_class_iv,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +sports_arena_playing_area_class_iv,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +sports_arena_playing_area_class_iv,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +sports_arena_playing_area_class_iv,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +sports_arena_playing_area_class_iv,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +audience_seating_all_other,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.125,0.25,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.625,0.25,0,0,0,0,0, +audience_seating_all_other,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.625,0.9,0.9,0.825,0.75,0.9,0.825,0.45,0.375,0,0,0,0,0,0, +audience_seating_all_other,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.625,0.9,0.9,0.825,0.75,0.9,0.825,0.45,0.375,0,0,0,0,0,0, +audience_seating_all_other,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +audience_seating_all_other,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0,0,0,0,0,0, +audience_seating_all_other,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0,0,0,0,0,0, +audience_seating_all_other,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.475,0.05,0.05,0.05, +audience_seating_all_other,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.645,0.9,0.9,0.83,0.76,0.9,0.83,0.475,0.405,0.05,0.05,0.05,0.05,0.05,0.05, +audience_seating_all_other,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.83,0.9,0.9,0.83,0.83,0.9,0.9,0.9,0.405,0.05,0.05,0.05,0.05,0.05,0.05, +confinement_cells,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0.125,0.125,0.125,0.125,0.125,0.125,0.125,0.125,0.125,0,0,0,0,0.25,0.75, +confinement_cells,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, +confinement_cells,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, +confinement_cells,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0,0,0.9,0.45, +confinement_cells,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.45, +confinement_cells,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.45, +confinement_cells,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +confinement_cells,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +confinement_cells,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +courtroom,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +courtroom,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, +courtroom,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, +courtroom,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +courtroom,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +courtroom,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +courtroom,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.07,0.07,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.07,0.07,0.07,0.07,0.05,0.05,0.05, +courtroom,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.07,0.07,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.07,0.07,0.07,0.07,0.05,0.05,0.05, +courtroom,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.07,0.07,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.07,0.07,0.07,0.07,0.05,0.05,0.05, +judges_chambers,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +judges_chambers,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +judges_chambers,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +judges_chambers,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +judges_chambers,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +judges_chambers,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +judges_chambers,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +judges_chambers,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +judges_chambers,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +library_stacks,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +library_stacks,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0,0,0,0,0,0, +library_stacks,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0,0,0,0,0,0, +library_stacks,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +library_stacks,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.5,0.9,0.9,0.9,0.75,0.9,0.75,0,0,0,0,0,0,0,0, +library_stacks,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.5,0.9,0.9,0.9,0.75,0.9,0.75,0,0,0,0,0,0,0,0, +library_stacks,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +library_stacks,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +library_stacks,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +storage_inactive,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.3,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.3,0,0,0,0,0,0, +storage_inactive,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0,0,0,0,0,0,0, +storage_inactive,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0,0,0,0,0,0,0, +storage_inactive,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +storage_inactive,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, +storage_inactive,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, +storage_inactive,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +storage_inactive,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +storage_inactive,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +dining_bar_lounge_leisure,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, +dining_bar_lounge_leisure,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, +dining_bar_lounge_leisure,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, +dining_bar_lounge_leisure,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +dining_bar_lounge_leisure,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +dining_bar_lounge_leisure,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +dining_bar_lounge_leisure,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +dining_bar_lounge_leisure,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +dining_bar_lounge_leisure,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +dining_cafeteria_fast_food,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, +dining_cafeteria_fast_food,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, +dining_cafeteria_fast_food,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, +dining_cafeteria_fast_food,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +dining_cafeteria_fast_food,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +dining_cafeteria_fast_food,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +dining_cafeteria_fast_food,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +dining_cafeteria_fast_food,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +dining_cafeteria_fast_food,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +dining_family,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, +dining_family,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, +dining_family,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, +dining_family,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +dining_family,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +dining_family,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +dining_family,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +dining_family,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +dining_family,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +computer_room,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0.75,0.75,0.75,0.5,0.5,0, +computer_room,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0.75,0.75,0.75,0.5,0.5,0, +computer_room,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0.75,0.75,0.75,0.5,0.5,0, +computer_room,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +computer_room,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +computer_room,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +computer_room,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05, +computer_room,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05, +computer_room,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05, +dormitory_living_quarters,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75,0.9, +dormitory_living_quarters,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75,0.9, +dormitory_living_quarters,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75,0.9, +dormitory_living_quarters,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.5,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.25, +dormitory_living_quarters,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.5,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.25, +dormitory_living_quarters,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.5,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.25, +dormitory_living_quarters,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +dormitory_living_quarters,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +dormitory_living_quarters,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +audience_seating_exercise_center,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_exercise_center,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_exercise_center,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_exercise_center,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_exercise_center,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_exercise_center,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_exercise_center,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_exercise_center,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_exercise_center,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +exam_treatment,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +exam_treatment,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +exam_treatment,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +exam_treatment,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +exam_treatment,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +exam_treatment,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +exam_treatment,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, +exam_treatment,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +exam_treatment,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +library_reading,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, +library_reading,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0,0,0,0,0,0,0, +library_reading,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0,0,0,0,0,0,0, +library_reading,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +library_reading,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, +library_reading,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, +library_reading,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +library_reading,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +library_reading,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +emergency_vehicle_garage,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0,0,0,0,0,0,0, +emergency_vehicle_garage,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +emergency_vehicle_garage,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +emergency_vehicle_garage,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0,0,0,0,0,0,0, +emergency_vehicle_garage,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +emergency_vehicle_garage,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +emergency_vehicle_garage,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +emergency_vehicle_garage,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +emergency_vehicle_garage,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +firestation_sleeping_quarters,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, +firestation_sleeping_quarters,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, +firestation_sleeping_quarters,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, +firestation_sleeping_quarters,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0, +firestation_sleeping_quarters,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0, +firestation_sleeping_quarters,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0, +firestation_sleeping_quarters,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +firestation_sleeping_quarters,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +firestation_sleeping_quarters,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +parking_area_interior,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0.125,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.705,0.9,0.575,0.125,0,0,0, +parking_area_interior,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.58,0.46,0.58,0.75,0.75,0.705,0.46,0.46,0.5,0.25,0,0,0,0,0, +parking_area_interior,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.58,0.46,0.58,0.75,0.75,0.705,0.46,0.46,0.5,0.25,0,0,0,0,0, +parking_area_interior,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0,0,0, +parking_area_interior,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +parking_area_interior,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +parking_area_interior,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +parking_area_interior,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +parking_area_interior,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +audience_seating_gymnasium,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_gymnasium,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_gymnasium,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_gymnasium,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_gymnasium,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_gymnasium,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_gymnasium,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_gymnasium,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_gymnasium,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +emergency_room,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.575,0.7,0.9,0.9,0.9,0.825,0.825,0.9,0.9,0.9,0.7,0.575,0.45,0.45,0,0,0, +emergency_room,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, +emergency_room,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, +emergency_room,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0,0,0, +emergency_room,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, +emergency_room,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, +emergency_room,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.475,0.475,0.475,0.05,0.05,0.05, +emergency_room,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.05,0.05,0.05, +emergency_room,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.05,0.05,0.05, +patient_room,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.575,0.7,0.9,0.9,0.9,0.825,0.825,0.9,0.9,0.9,0.7,0.575,0.45,0.45,0.45,0.45,0.45, +patient_room,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45, +patient_room,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45, +patient_room,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.15,0.8,0.9,0.9,0.9,0.9,0.9,0.9,0.8,0.6,0.6,0.8,0.9,0.45,0.45,0.45,0.35,0.15, +patient_room,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.15,0.35,0.45,0.45,0.45,0.45,0.45,0.45,0.35,0.15,0.15,0.35,0.45,0.45,0.45,0.45,0.35,0.15, +patient_room,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.15,0.35,0.45,0.45,0.45,0.45,0.45,0.45,0.35,0.15,0.15,0.35,0.45,0.45,0.45,0.45,0.35,0.15, +patient_room,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.475,0.475,0.475,0.475,0.475,0.195, +patient_room,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.195, +patient_room,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.195, +pharmacy,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +pharmacy,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +pharmacy,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +pharmacy,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +pharmacy,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +pharmacy,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +pharmacy,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, +pharmacy,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +pharmacy,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +corridor_hospital,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +corridor_hospital,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +corridor_hospital,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +corridor_hospital,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +corridor_hospital,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +corridor_hospital,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +corridor_hospital,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +corridor_hospital,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +corridor_hospital,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +fellowship_hall_religious_facility,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +fellowship_hall_religious_facility,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, +fellowship_hall_religious_facility,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, +fellowship_hall_religious_facility,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +fellowship_hall_religious_facility,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, +fellowship_hall_religious_facility,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, +fellowship_hall_religious_facility,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +fellowship_hall_religious_facility,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.05,0.05,0.05, +fellowship_hall_religious_facility,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.05,0.05,0.05, +lounge_breakroom_healthcare_facility,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +lounge_breakroom_healthcare_facility,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +lounge_breakroom_healthcare_facility,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +lounge_breakroom_healthcare_facility,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +lounge_breakroom_healthcare_facility,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +lounge_breakroom_healthcare_facility,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +lounge_breakroom_healthcare_facility,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, +lounge_breakroom_healthcare_facility,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, +lounge_breakroom_healthcare_facility,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, +operating_room,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +operating_room,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +operating_room,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +operating_room,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.18,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.58,0.45,0.18, +operating_room,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.18,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.58,0.45,0.18, +operating_room,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.18,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.58,0.45,0.18, +operating_room,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +operating_room,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +operating_room,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +physical_therapy,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +physical_therapy,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +physical_therapy,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +physical_therapy,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +physical_therapy,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +physical_therapy,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +physical_therapy,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, +physical_therapy,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, +physical_therapy,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, +storage_50_to_1000_sf_hospital,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, +storage_50_to_1000_sf_hospital,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, +storage_50_to_1000_sf_hospital,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, +storage_50_to_1000_sf_hospital,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, +storage_50_to_1000_sf_hospital,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, +storage_50_to_1000_sf_hospital,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, +storage_50_to_1000_sf_hospital,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +storage_50_to_1000_sf_hospital,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +storage_50_to_1000_sf_hospital,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +storage_lt_50_sf_hospital,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, +storage_lt_50_sf_hospital,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, +storage_lt_50_sf_hospital,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, +storage_lt_50_sf_hospital,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, +storage_lt_50_sf_hospital,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, +storage_lt_50_sf_hospital,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, +storage_lt_50_sf_hospital,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +storage_lt_50_sf_hospital,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +storage_lt_50_sf_hospital,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +guest_room,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75,0.9, +guest_room,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75,0.9, +guest_room,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75,0.9, +guest_room,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9, +guest_room,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9, +guest_room,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9, +guest_room,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +guest_room,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +guest_room,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +lobby_hotel,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.3, +lobby_hotel,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.3, +lobby_hotel,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.3, +lobby_hotel,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +lobby_hotel,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +lobby_hotel,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +lobby_hotel,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +lobby_hotel,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +lobby_hotel,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +library_cataloging,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +library_cataloging,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +library_cataloging,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +library_cataloging,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +library_cataloging,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +library_cataloging,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +library_cataloging,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +library_cataloging,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +library_cataloging,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +museum_exhibit_area,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.375,0.45,0.45,0.375,0.375,0.45,0.45,0.7,0.5,0.125,0,0,0,0,0, +museum_exhibit_area,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.375,0.45,0.45,0.375,0.375,0.45,0.45,0.7,0.5,0.125,0,0,0,0,0, +museum_exhibit_area,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.375,0.45,0.45,0.375,0.375,0.45,0.45,0.7,0.5,0.125,0,0,0,0,0, +museum_exhibit_area,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45, +museum_exhibit_area,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45, +museum_exhibit_area,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45, +museum_exhibit_area,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.055,0.055,0.055,0.055,0.055,0.05, +museum_exhibit_area,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.055,0.055,0.055,0.055,0.055,0.05, +museum_exhibit_area,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.055,0.055,0.055,0.055,0.055,0.05, +corridor_manufacturing_facility,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +corridor_manufacturing_facility,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +corridor_manufacturing_facility,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +corridor_manufacturing_facility,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +corridor_manufacturing_facility,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +corridor_manufacturing_facility,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +corridor_manufacturing_facility,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.04,0.04,0.04,0.04,0.04,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.04,0.04,0.04, +corridor_manufacturing_facility,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.04,0.04,0.04,0.04,0.04,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.04,0.04,0.04, +corridor_manufacturing_facility,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.04,0.04,0.04,0.04,0.04,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.04,0.04,0.04, +manufacturing_equipment_room,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +manufacturing_equipment_room,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +manufacturing_equipment_room,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +manufacturing_equipment_room,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +manufacturing_equipment_room,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +manufacturing_equipment_room,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +manufacturing_equipment_room,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +manufacturing_equipment_room,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +manufacturing_equipment_room,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +manufacturing_low_bay,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +manufacturing_low_bay,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +manufacturing_low_bay,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +manufacturing_low_bay,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +manufacturing_low_bay,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +manufacturing_low_bay,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +manufacturing_low_bay,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +manufacturing_low_bay,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +manufacturing_low_bay,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +performing_arts_dressing_room,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.825,0,0,0,0,0,0, +performing_arts_dressing_room,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0,0,0,0,0,0, +performing_arts_dressing_room,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0,0,0,0,0,0, +performing_arts_dressing_room,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +performing_arts_dressing_room,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0,0,0,0,0,0, +performing_arts_dressing_room,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0,0,0,0,0,0, +performing_arts_dressing_room,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.045,0.045,0.045,0.045,0.055,0.055,0.055,0.055,0.48,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.475,0.475,0.475,0.045,0.045,0.045, +performing_arts_dressing_room,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.045,0.045,0.045,0.045,0.055,0.055,0.055,0.055,0.48,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.48,0.055,0.055,0.055,0.045,0.045,0.045, +performing_arts_dressing_room,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.045,0.045,0.045,0.045,0.045,0.045,0.045,0.045,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.48,0.055,0.055,0.055,0.045,0.045,0.045, +audience_seating_auditorium,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_auditorium,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_auditorium,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_auditorium,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_auditorium,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_auditorium,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_auditorium,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_auditorium,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_auditorium,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_motion_picture_theater,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_motion_picture_theater,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_motion_picture_theater,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_motion_picture_theater,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_motion_picture_theater,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_motion_picture_theater,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_motion_picture_theater,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_motion_picture_theater,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_motion_picture_theater,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +lobby_motion_picture_theater,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +lobby_motion_picture_theater,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +lobby_motion_picture_theater,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +lobby_motion_picture_theater,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +lobby_motion_picture_theater,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +lobby_motion_picture_theater,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +lobby_motion_picture_theater,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +lobby_motion_picture_theater,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +lobby_motion_picture_theater,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +dwelling_unit,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, +dwelling_unit,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, +dwelling_unit,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, +dwelling_unit,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0,0,0,0,0,0,0,0,0,0.2,0.2,0.2,0.2,0, +dwelling_unit,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0,0,0,0,0,0,0,0,0,0.2,0.2,0.2,0.2,0, +dwelling_unit,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0,0,0,0,0,0,0,0,0,0.2,0.2,0.2,0.2,0, +dwelling_unit,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +dwelling_unit,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +dwelling_unit,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, +museum_restoration,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +museum_restoration,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +museum_restoration,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +museum_restoration,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +museum_restoration,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +museum_restoration,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +museum_restoration,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +museum_restoration,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +museum_restoration,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +banking_activity,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +banking_activity,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +banking_activity,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +banking_activity,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +banking_activity,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +banking_activity,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +banking_activity,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, +banking_activity,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +banking_activity,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +warehouse_fine_storage,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.45,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.45,0,0,0,0,0,0, +warehouse_fine_storage,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.45,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.45,0,0,0,0,0,0, +warehouse_fine_storage,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.45,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.45,0,0,0,0,0,0, +warehouse_fine_storage,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.45,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.45,0,0,0,0,0,0, +warehouse_fine_storage,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.45,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.45,0,0,0,0,0,0, +warehouse_fine_storage,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.45,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.45,0,0,0,0,0,0, +warehouse_fine_storage,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +warehouse_fine_storage,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +warehouse_fine_storage,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +classroom_lecture_training_penitentiary,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +classroom_lecture_training_penitentiary,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +classroom_lecture_training_penitentiary,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +classroom_lecture_training_penitentiary,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +classroom_lecture_training_penitentiary,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +classroom_lecture_training_penitentiary,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +classroom_lecture_training_penitentiary,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.04,0.04,0.04,0.04,0.04,0.04,0.04, +classroom_lecture_training_penitentiary,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04, +classroom_lecture_training_penitentiary,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04, +dining_penitentiary,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0.25,0.9,0.9,0.25,0,0.25,0.9,0.9,0.5,0,0,0.5,0.9,0.9,0.5,0,0,0, +dining_penitentiary,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0.25,0.9,0.9,0.25,0,0.25,0.9,0.9,0.5,0,0,0.5,0.9,0.9,0.5,0,0,0, +dining_penitentiary,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0.25,0.9,0.9,0.25,0,0.25,0.9,0.9,0.5,0,0,0.5,0.9,0.9,0.5,0,0,0, +dining_penitentiary,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0,0.9,0.9,0.9,0.9,0,0,0.9,0.9,0.9,0.9,0,0,0, +dining_penitentiary,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0,0.9,0.9,0.9,0.9,0,0,0.9,0.9,0.9,0.9,0,0,0, +dining_penitentiary,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0,0.9,0.9,0.9,0.9,0,0,0.9,0.9,0.9,0.9,0,0,0, +dining_penitentiary,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.9,0.9,0.3,0.07,0.3,0.9,0.9,0.54,0.07,0.07,0.54,0.9,0.9,0.54,0.07,0.07,0.07, +dining_penitentiary,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.9,0.9,0.3,0.07,0.3,0.9,0.9,0.54,0.07,0.07,0.54,0.9,0.9,0.54,0.07,0.07,0.07, +dining_penitentiary,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.9,0.9,0.3,0.07,0.3,0.9,0.9,0.54,0.07,0.07,0.54,0.9,0.9,0.54,0.07,0.07,0.07, +audience_seating_performing_arts_theater,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_performing_arts_theater,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_performing_arts_theater,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_performing_arts_theater,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_performing_arts_theater,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_performing_arts_theater,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_performing_arts_theater,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_performing_arts_theater,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_performing_arts_theater,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +lobby_performing_arts_theater,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +lobby_performing_arts_theater,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +lobby_performing_arts_theater,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, +lobby_performing_arts_theater,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +lobby_performing_arts_theater,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +lobby_performing_arts_theater,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +lobby_performing_arts_theater,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +lobby_performing_arts_theater,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +lobby_performing_arts_theater,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +audience_seating_religious_facility,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +audience_seating_religious_facility,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +audience_seating_religious_facility,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +audience_seating_religious_facility,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +audience_seating_religious_facility,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +audience_seating_religious_facility,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +audience_seating_religious_facility,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +audience_seating_religious_facility,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +audience_seating_religious_facility,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +worship_pulpit_choir_area,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +worship_pulpit_choir_area,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +worship_pulpit_choir_area,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +worship_pulpit_choir_area,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, +worship_pulpit_choir_area,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +worship_pulpit_choir_area,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +worship_pulpit_choir_area,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +worship_pulpit_choir_area,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +worship_pulpit_choir_area,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +classroom_lecture_training_preschool_to_12th,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, +classroom_lecture_training_preschool_to_12th,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +classroom_lecture_training_preschool_to_12th,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +classroom_lecture_training_preschool_to_12th,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +classroom_lecture_training_preschool_to_12th,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +classroom_lecture_training_preschool_to_12th,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +classroom_lecture_training_preschool_to_12th,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, +classroom_lecture_training_preschool_to_12th,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +classroom_lecture_training_preschool_to_12th,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, +sports_arena_playing_area_class_ii,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.125,0.25,0.9,0.9,0.9,0.825,0.825,0.9,0.9,0.9,0.7,0.575,0.45,0.45,0,0,0, +sports_arena_playing_area_class_ii,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.825,0.9,0.9,0.825,0.825,0.9,0.9,0.9,0.825,0.45,0.45,0.45,0,0,0, +sports_arena_playing_area_class_ii,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.825,0.9,0.9,0.825,0.825,0.9,0.9,0.9,0.825,0.45,0.45,0.45,0,0,0, +sports_arena_playing_area_class_ii,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0,0,0, +sports_arena_playing_area_class_ii,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0.45,0,0,0, +sports_arena_playing_area_class_ii,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0.45,0,0,0, +sports_arena_playing_area_class_ii,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.475,0.05,0.05,0.05, +sports_arena_playing_area_class_ii,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.83,0.9,0.9,0.83,0.83,0.9,0.9,0.9,0.83,0.475,0.475,0.475,0.05,0.05,0.05, +sports_arena_playing_area_class_ii,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.83,0.9,0.9,0.83,0.83,0.9,0.9,0.9,0.83,0.475,0.475,0.475,0.05,0.05,0.05, +audience_seating_sports_arena,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_sports_arena,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_sports_arena,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, +audience_seating_sports_arena,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_sports_arena,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_sports_arena,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, +audience_seating_sports_arena,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_sports_arena,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +audience_seating_sports_arena,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, +airport_concourse,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0.25,0.25,0.25,0.25,0.25, +airport_concourse,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0.25,0.25,0.25,0.25,0.25, +airport_concourse,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0.25,0.25,0.25,0.25,0.25, +airport_concourse,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +airport_concourse,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +airport_concourse,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +airport_concourse,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +airport_concourse,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +airport_concourse,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +atrium_lt_20_ft_height,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_lt_20_ft_height,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_lt_20_ft_height,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_lt_20_ft_height,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_lt_20_ft_height,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_lt_20_ft_height,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_lt_20_ft_height,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +atrium_lt_20_ft_height,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +atrium_lt_20_ft_height,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +atrium_gt_40_ft_height,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_gt_40_ft_height,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_gt_40_ft_height,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_gt_40_ft_height,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_gt_40_ft_height,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_gt_40_ft_height,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_gt_40_ft_height,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +atrium_gt_40_ft_height,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +atrium_gt_40_ft_height,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +atrium_gte_20_ft_and_lte_40_ft_in_height,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_gte_20_ft_and_lte_40_ft_in_height,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_gte_20_ft_and_lte_40_ft_in_height,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_gte_20_ft_and_lte_40_ft_in_height,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_gte_20_ft_and_lte_40_ft_in_height,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_gte_20_ft_and_lte_40_ft_in_height,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +atrium_gte_20_ft_and_lte_40_ft_in_height,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +atrium_gte_20_ft_and_lte_40_ft_in_height,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +atrium_gte_20_ft_and_lte_40_ft_in_height,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, +baggage_carousel,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0.25,0.25,0.25,0.25,0.25, +baggage_carousel,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0.25,0.25,0.25,0.25,0.25, +baggage_carousel,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0.25,0.25,0.25,0.25,0.25, +baggage_carousel,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +baggage_carousel,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +baggage_carousel,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +baggage_carousel,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +baggage_carousel,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +baggage_carousel,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +seating_area_general,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25,0.25, +seating_area_general,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25,0.25, +seating_area_general,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25,0.25, +seating_area_general,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +seating_area_general,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +seating_area_general,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +seating_area_general,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +seating_area_general,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +seating_area_general,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, +transportation_ticket_counter,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +transportation_ticket_counter,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +transportation_ticket_counter,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, +transportation_ticket_counter,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +transportation_ticket_counter,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +transportation_ticket_counter,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, +transportation_ticket_counter,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25,0.25,0.25, +transportation_ticket_counter,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25,0.25,0.25, +transportation_ticket_counter,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25,0.25,0.25, +warehouse_bulk_storage,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +warehouse_bulk_storage,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +warehouse_bulk_storage,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +warehouse_bulk_storage,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +warehouse_bulk_storage,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +warehouse_bulk_storage,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, +warehouse_bulk_storage,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +warehouse_bulk_storage,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, +warehouse_bulk_storage,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, diff --git a/data/openstudio_standards_data/database_files/support_schedules.json b/data/openstudio_standards_data/database_files/support_schedules.json index 6b4d769dea..381e5007d8 100644 --- a/data/openstudio_standards_data/database_files/support_schedules.json +++ b/data/openstudio_standards_data/database_files/support_schedules.json @@ -4,8 +4,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -38,8 +38,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -72,8 +72,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -106,8 +106,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -140,8 +140,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -174,8 +174,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -208,8 +208,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -242,8 +242,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -276,8 +276,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -310,8 +310,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -344,8 +344,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -378,8 +378,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -412,8 +412,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -446,8 +446,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -480,8 +480,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -514,8 +514,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.06, "hr_2": 0.06, @@ -548,8 +548,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.06, "hr_2": 0.06, @@ -582,8 +582,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.06, "hr_2": 0.06, @@ -616,8 +616,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -650,8 +650,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -684,8 +684,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -718,8 +718,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -752,8 +752,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -786,8 +786,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -820,8 +820,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.24, "hr_2": 0.24, @@ -854,8 +854,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.24, "hr_2": 0.24, @@ -888,8 +888,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.24, "hr_2": 0.24, @@ -922,8 +922,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -956,8 +956,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -990,8 +990,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -1024,8 +1024,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -1058,8 +1058,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -1092,8 +1092,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -1126,8 +1126,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -1160,8 +1160,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -1194,8 +1194,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -1228,8 +1228,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -1262,8 +1262,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -1296,8 +1296,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -1330,8 +1330,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -1364,8 +1364,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -1398,8 +1398,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -1432,8 +1432,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -1466,8 +1466,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -1500,8 +1500,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -1534,8 +1534,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -1568,8 +1568,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -1602,8 +1602,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -1636,8 +1636,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -1670,8 +1670,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -1704,8 +1704,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -1738,8 +1738,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -1772,8 +1772,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -1806,8 +1806,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -1840,8 +1840,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -1874,8 +1874,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -1908,8 +1908,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -1942,8 +1942,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -1976,8 +1976,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -2010,8 +2010,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -2044,8 +2044,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -2078,8 +2078,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -2112,8 +2112,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -2146,8 +2146,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -2180,8 +2180,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -2214,8 +2214,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -2248,8 +2248,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -2282,8 +2282,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -2316,8 +2316,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -2350,8 +2350,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -2384,8 +2384,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -2418,8 +2418,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -2452,8 +2452,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -2486,8 +2486,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -2520,8 +2520,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -2554,8 +2554,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -2588,8 +2588,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -2622,8 +2622,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -2656,8 +2656,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -2690,8 +2690,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -2724,8 +2724,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -2758,8 +2758,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -2792,8 +2792,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -2826,8 +2826,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -2860,8 +2860,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -2894,8 +2894,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -2928,8 +2928,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -2962,8 +2962,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -2996,8 +2996,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -3030,8 +3030,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -3064,8 +3064,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -3098,8 +3098,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -3132,8 +3132,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -3166,8 +3166,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -3200,8 +3200,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -3234,8 +3234,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -3268,8 +3268,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -3302,8 +3302,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -3336,8 +3336,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -3370,8 +3370,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -3404,8 +3404,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -3438,8 +3438,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -3472,8 +3472,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -3506,8 +3506,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -3540,8 +3540,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -3574,8 +3574,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -3608,8 +3608,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -3642,8 +3642,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -3676,8 +3676,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -3710,8 +3710,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -3744,8 +3744,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -3778,8 +3778,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -3812,8 +3812,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -3846,8 +3846,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -3880,8 +3880,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -3914,8 +3914,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -3948,8 +3948,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -3982,8 +3982,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -4016,8 +4016,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -4050,8 +4050,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -4084,8 +4084,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -4118,8 +4118,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -4152,8 +4152,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -4186,8 +4186,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -4220,8 +4220,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -4254,8 +4254,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -4288,8 +4288,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -4322,8 +4322,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -4356,8 +4356,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -4390,8 +4390,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -4424,8 +4424,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -4458,8 +4458,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -4492,8 +4492,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -4526,8 +4526,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -4560,8 +4560,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -4594,8 +4594,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -4628,8 +4628,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -4662,8 +4662,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -4696,8 +4696,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -4730,8 +4730,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -4764,8 +4764,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -4798,8 +4798,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.045, "hr_2": 0.045, @@ -4832,8 +4832,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.045, "hr_2": 0.045, @@ -4866,8 +4866,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.045, "hr_2": 0.045, @@ -4900,8 +4900,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -4934,8 +4934,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -4968,8 +4968,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -5002,8 +5002,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -5036,8 +5036,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -5070,8 +5070,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -5104,8 +5104,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -5138,8 +5138,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -5172,8 +5172,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -5206,8 +5206,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -5240,8 +5240,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -5274,8 +5274,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -5308,8 +5308,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -5342,8 +5342,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -5376,8 +5376,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -5410,8 +5410,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -5444,8 +5444,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -5478,8 +5478,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -5512,8 +5512,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -5546,8 +5546,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -5580,8 +5580,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -5614,8 +5614,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -5648,8 +5648,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -5682,8 +5682,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -5716,8 +5716,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.06, "hr_2": 0.06, @@ -5750,8 +5750,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.06, "hr_2": 0.06, @@ -5784,8 +5784,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.06, "hr_2": 0.06, @@ -5818,8 +5818,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -5852,8 +5852,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -5886,8 +5886,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -5920,8 +5920,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -5954,8 +5954,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -5988,8 +5988,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -6022,8 +6022,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -6056,8 +6056,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -6090,8 +6090,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -6124,8 +6124,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -6158,8 +6158,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -6192,8 +6192,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -6226,8 +6226,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -6260,8 +6260,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -6294,8 +6294,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -6328,8 +6328,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -6362,8 +6362,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -6396,8 +6396,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -6430,8 +6430,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -6464,8 +6464,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -6498,8 +6498,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -6532,8 +6532,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -6566,8 +6566,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -6600,8 +6600,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -6634,8 +6634,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -6668,8 +6668,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -6702,8 +6702,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -6736,8 +6736,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -6770,8 +6770,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -6804,8 +6804,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -6838,8 +6838,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -6872,8 +6872,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -6906,8 +6906,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -6940,8 +6940,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -6974,8 +6974,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -7008,8 +7008,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -7042,8 +7042,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -7076,8 +7076,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -7110,8 +7110,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -7144,8 +7144,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -7178,8 +7178,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -7212,8 +7212,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -7246,8 +7246,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -7280,8 +7280,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -7314,8 +7314,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -7348,8 +7348,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -7382,8 +7382,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -7416,8 +7416,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -7450,8 +7450,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -7484,8 +7484,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -7518,8 +7518,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -7552,8 +7552,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -7586,8 +7586,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -7620,8 +7620,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -7654,8 +7654,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -7688,8 +7688,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -7722,8 +7722,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -7756,8 +7756,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -7790,8 +7790,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -7824,8 +7824,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -7858,8 +7858,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -7892,8 +7892,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -7926,8 +7926,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -7960,8 +7960,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -7994,8 +7994,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -8028,8 +8028,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -8062,8 +8062,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -8096,8 +8096,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -8130,8 +8130,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -8164,8 +8164,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -8198,8 +8198,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -8232,8 +8232,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -8266,8 +8266,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -8300,8 +8300,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -8334,8 +8334,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -8368,8 +8368,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -8402,8 +8402,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -8436,8 +8436,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -8470,8 +8470,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -8504,8 +8504,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -8538,8 +8538,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -8572,8 +8572,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -8606,8 +8606,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -8640,8 +8640,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -8674,8 +8674,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -8708,8 +8708,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -8742,8 +8742,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -8776,8 +8776,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -8810,8 +8810,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -8844,8 +8844,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -8878,8 +8878,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -8912,8 +8912,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -8946,8 +8946,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -8980,8 +8980,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -9014,8 +9014,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -9048,8 +9048,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -9082,8 +9082,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -9116,8 +9116,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -9150,8 +9150,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -9184,8 +9184,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -9218,8 +9218,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -9252,8 +9252,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -9286,8 +9286,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -9320,8 +9320,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -9354,8 +9354,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -9388,8 +9388,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -9422,8 +9422,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -9456,8 +9456,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -9490,8 +9490,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -9524,8 +9524,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -9558,8 +9558,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -9592,8 +9592,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -9626,8 +9626,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -9660,8 +9660,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -9694,8 +9694,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.07, "hr_2": 0.07, @@ -9728,8 +9728,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.07, "hr_2": 0.07, @@ -9762,8 +9762,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.07, "hr_2": 0.07, @@ -9796,8 +9796,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -9830,8 +9830,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -9864,8 +9864,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -9898,8 +9898,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -9932,8 +9932,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -9966,8 +9966,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -10000,8 +10000,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -10034,8 +10034,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -10068,8 +10068,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -10102,8 +10102,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -10136,8 +10136,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -10170,8 +10170,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -10204,8 +10204,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -10238,8 +10238,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -10272,8 +10272,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -10306,8 +10306,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -10340,8 +10340,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -10374,8 +10374,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -10408,8 +10408,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -10442,8 +10442,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -10476,8 +10476,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -10510,8 +10510,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -10544,8 +10544,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -10578,8 +10578,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -10612,8 +10612,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -10646,8 +10646,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -10680,8 +10680,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -10714,8 +10714,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -10748,8 +10748,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -10782,8 +10782,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -10816,8 +10816,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -10850,8 +10850,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -10884,8 +10884,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -10918,8 +10918,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -10952,8 +10952,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -10986,8 +10986,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -11020,8 +11020,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -11054,8 +11054,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -11088,8 +11088,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -11122,8 +11122,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -11156,8 +11156,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -11190,8 +11190,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -11224,8 +11224,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -11258,8 +11258,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -11292,8 +11292,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -11326,8 +11326,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -11360,8 +11360,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -11394,8 +11394,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -11428,8 +11428,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -11462,8 +11462,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -11496,8 +11496,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -11530,8 +11530,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -11564,8 +11564,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -11598,8 +11598,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -11632,8 +11632,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -11666,8 +11666,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -11700,8 +11700,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -11734,8 +11734,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -11768,8 +11768,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -11802,8 +11802,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -11836,8 +11836,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -11870,8 +11870,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -11904,8 +11904,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -11938,8 +11938,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -11972,8 +11972,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -12006,8 +12006,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -12040,8 +12040,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -12074,8 +12074,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -12108,8 +12108,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -12142,8 +12142,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -12176,8 +12176,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -12210,8 +12210,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -12244,8 +12244,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -12278,8 +12278,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -12312,8 +12312,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -12346,8 +12346,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -12380,8 +12380,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -12414,8 +12414,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -12448,8 +12448,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.07, "hr_2": 0.07, @@ -12482,8 +12482,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.07, "hr_2": 0.07, @@ -12516,8 +12516,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.07, "hr_2": 0.07, @@ -12550,8 +12550,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -12584,8 +12584,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -12618,8 +12618,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -12652,8 +12652,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -12686,8 +12686,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -12720,8 +12720,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -12754,8 +12754,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.06, "hr_2": 0.06, @@ -12788,8 +12788,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.06, "hr_2": 0.06, @@ -12822,8 +12822,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.06, "hr_2": 0.06, @@ -12856,8 +12856,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -12890,8 +12890,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -12924,8 +12924,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -12958,8 +12958,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -12992,8 +12992,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -13026,8 +13026,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -13060,8 +13060,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -13094,8 +13094,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -13128,8 +13128,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -13162,8 +13162,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -13196,8 +13196,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -13230,8 +13230,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -13264,8 +13264,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -13298,8 +13298,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -13332,8 +13332,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -13366,8 +13366,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -13400,8 +13400,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -13434,8 +13434,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -13468,8 +13468,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -13502,8 +13502,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -13536,8 +13536,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -13570,8 +13570,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -13604,8 +13604,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -13638,8 +13638,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -13672,8 +13672,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -13706,8 +13706,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -13740,8 +13740,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -13774,8 +13774,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -13808,8 +13808,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -13842,8 +13842,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -13876,8 +13876,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -13910,8 +13910,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -13944,8 +13944,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -13978,8 +13978,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.07, "hr_2": 0.07, @@ -14012,8 +14012,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.07, "hr_2": 0.07, @@ -14046,8 +14046,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.07, "hr_2": 0.07, @@ -14080,8 +14080,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -14114,8 +14114,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -14148,8 +14148,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -14182,8 +14182,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -14216,8 +14216,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -14250,8 +14250,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -14284,8 +14284,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -14318,8 +14318,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -14352,8 +14352,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -14386,8 +14386,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -14420,8 +14420,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -14454,8 +14454,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -14488,8 +14488,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -14522,8 +14522,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -14556,8 +14556,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -14590,8 +14590,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.06, "hr_2": 0.06, @@ -14624,8 +14624,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.06, "hr_2": 0.06, @@ -14658,8 +14658,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.06, "hr_2": 0.06, @@ -14692,8 +14692,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -14726,8 +14726,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -14760,8 +14760,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -14794,8 +14794,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -14828,8 +14828,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -14862,8 +14862,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -14896,8 +14896,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -14930,8 +14930,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -14964,8 +14964,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -14998,8 +14998,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.45, "hr_2": 0.45, @@ -15032,8 +15032,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.45, "hr_2": 0.45, @@ -15066,8 +15066,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.45, "hr_2": 0.45, @@ -15100,8 +15100,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -15134,8 +15134,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -15168,8 +15168,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -15202,8 +15202,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -15236,8 +15236,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -15270,8 +15270,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -15304,8 +15304,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -15338,8 +15338,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -15372,8 +15372,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -15406,8 +15406,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -15440,8 +15440,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -15474,8 +15474,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -15508,8 +15508,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -15542,8 +15542,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -15576,8 +15576,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -15610,8 +15610,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -15644,8 +15644,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -15678,8 +15678,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -15712,8 +15712,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -15746,8 +15746,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -15780,8 +15780,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -15814,8 +15814,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -15848,8 +15848,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -15882,8 +15882,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -15916,8 +15916,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -15950,8 +15950,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -15984,8 +15984,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -16018,8 +16018,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -16052,8 +16052,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -16086,8 +16086,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -16120,8 +16120,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -16154,8 +16154,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -16188,8 +16188,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -16222,8 +16222,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -16256,8 +16256,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -16290,8 +16290,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -16324,8 +16324,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -16358,8 +16358,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -16392,8 +16392,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -16426,8 +16426,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -16460,8 +16460,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -16494,8 +16494,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -16528,8 +16528,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -16562,8 +16562,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -16596,8 +16596,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -16630,8 +16630,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -16664,8 +16664,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -16698,8 +16698,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -16732,8 +16732,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -16766,8 +16766,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -16800,8 +16800,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -16834,8 +16834,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -16868,8 +16868,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -16902,8 +16902,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -16936,8 +16936,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -16970,8 +16970,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -17004,8 +17004,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -17038,8 +17038,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -17072,8 +17072,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -17106,8 +17106,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -17140,8 +17140,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -17174,8 +17174,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -17208,8 +17208,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -17242,8 +17242,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -17276,8 +17276,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -17310,8 +17310,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -17344,8 +17344,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -17378,8 +17378,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -17412,8 +17412,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -17446,8 +17446,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -17480,8 +17480,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -17514,8 +17514,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -17548,8 +17548,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -17582,8 +17582,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -17616,8 +17616,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -17650,8 +17650,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -17684,8 +17684,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -17718,8 +17718,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -17752,8 +17752,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -17786,8 +17786,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -17820,8 +17820,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -17854,8 +17854,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -17888,8 +17888,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -17922,8 +17922,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -17956,8 +17956,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.07, "hr_2": 0.07, @@ -17990,8 +17990,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.07, "hr_2": 0.07, @@ -18024,8 +18024,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.07, "hr_2": 0.07, @@ -18058,8 +18058,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -18092,8 +18092,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -18126,8 +18126,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -18160,8 +18160,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -18194,8 +18194,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -18228,8 +18228,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -18262,8 +18262,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -18296,8 +18296,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -18330,8 +18330,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -18364,8 +18364,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -18398,8 +18398,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -18432,8 +18432,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -18466,8 +18466,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -18500,8 +18500,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -18534,8 +18534,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -18568,8 +18568,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -18602,8 +18602,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -18636,8 +18636,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -18670,8 +18670,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -18704,8 +18704,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -18738,8 +18738,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -18772,8 +18772,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.45, "hr_2": 0.45, @@ -18806,8 +18806,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.45, "hr_2": 0.45, @@ -18840,8 +18840,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.45, "hr_2": 0.45, @@ -18874,8 +18874,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -18908,8 +18908,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -18942,8 +18942,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -18976,8 +18976,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -19010,8 +19010,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -19044,8 +19044,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -19078,8 +19078,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -19112,8 +19112,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -19146,8 +19146,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -19180,8 +19180,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.04, "hr_2": 0.04, @@ -19214,8 +19214,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.04, "hr_2": 0.04, @@ -19248,8 +19248,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.04, "hr_2": 0.04, @@ -19282,8 +19282,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -19316,8 +19316,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -19350,8 +19350,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -19384,8 +19384,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -19418,8 +19418,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -19452,8 +19452,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -19486,8 +19486,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -19520,8 +19520,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -19554,8 +19554,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -19588,8 +19588,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -19622,8 +19622,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -19656,8 +19656,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -19690,8 +19690,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -19724,8 +19724,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -19758,8 +19758,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -19792,8 +19792,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -19826,8 +19826,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -19860,8 +19860,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -19894,8 +19894,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -19928,8 +19928,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -19962,8 +19962,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -19996,8 +19996,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -20030,8 +20030,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -20064,8 +20064,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -20098,8 +20098,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.045, "hr_2": 0.045, @@ -20132,8 +20132,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.045, "hr_2": 0.045, @@ -20166,8 +20166,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.045, "hr_2": 0.045, @@ -20200,8 +20200,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -20234,8 +20234,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -20268,8 +20268,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -20302,8 +20302,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -20336,8 +20336,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -20370,8 +20370,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -20404,8 +20404,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.06, "hr_2": 0.06, @@ -20438,8 +20438,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.06, "hr_2": 0.06, @@ -20472,8 +20472,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.06, "hr_2": 0.06, @@ -20506,8 +20506,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -20540,8 +20540,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -20574,8 +20574,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -20608,8 +20608,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -20642,8 +20642,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -20676,8 +20676,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -20710,8 +20710,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.06, "hr_2": 0.06, @@ -20744,8 +20744,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.06, "hr_2": 0.06, @@ -20778,8 +20778,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.06, "hr_2": 0.06, @@ -20812,8 +20812,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -20846,8 +20846,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -20880,8 +20880,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -20914,8 +20914,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -20948,8 +20948,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -20982,8 +20982,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -21016,8 +21016,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -21050,8 +21050,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -21084,8 +21084,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -21118,8 +21118,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -21152,8 +21152,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -21186,8 +21186,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -21220,8 +21220,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -21254,8 +21254,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -21288,8 +21288,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -21322,8 +21322,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.07, "hr_2": 0.07, @@ -21356,8 +21356,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.07, "hr_2": 0.07, @@ -21390,8 +21390,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.07, "hr_2": 0.07, @@ -21424,8 +21424,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -21458,8 +21458,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -21492,8 +21492,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -21526,8 +21526,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -21560,8 +21560,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -21594,8 +21594,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -21628,8 +21628,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -21662,8 +21662,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -21696,8 +21696,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -21730,8 +21730,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -21764,8 +21764,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -21798,8 +21798,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -21832,8 +21832,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -21866,8 +21866,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -21900,8 +21900,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -21934,8 +21934,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -21968,8 +21968,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -22002,8 +22002,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -22036,8 +22036,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -22070,8 +22070,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -22104,8 +22104,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -22138,8 +22138,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -22172,8 +22172,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -22206,8 +22206,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -22240,8 +22240,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -22274,8 +22274,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -22308,8 +22308,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -22342,8 +22342,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -22376,8 +22376,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -22410,8 +22410,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -22444,8 +22444,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -22478,8 +22478,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -22512,8 +22512,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -22546,8 +22546,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.04, "hr_2": 0.04, @@ -22580,8 +22580,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.04, "hr_2": 0.04, @@ -22614,8 +22614,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.04, "hr_2": 0.04, @@ -22648,8 +22648,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -22682,8 +22682,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -22716,8 +22716,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -22750,8 +22750,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -22784,8 +22784,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -22818,8 +22818,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -22852,8 +22852,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.07, "hr_2": 0.07, @@ -22886,8 +22886,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.07, "hr_2": 0.07, @@ -22920,8 +22920,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.07, "hr_2": 0.07, @@ -22954,8 +22954,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -22988,8 +22988,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -23022,8 +23022,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -23056,8 +23056,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -23090,8 +23090,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -23124,8 +23124,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -23158,8 +23158,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.06, "hr_2": 0.06, @@ -23192,8 +23192,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.06, "hr_2": 0.06, @@ -23226,8 +23226,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.06, "hr_2": 0.06, @@ -23260,8 +23260,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -23294,8 +23294,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -23328,8 +23328,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -23362,8 +23362,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -23396,8 +23396,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -23430,8 +23430,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -23464,8 +23464,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -23498,8 +23498,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -23532,8 +23532,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -23566,8 +23566,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -23600,8 +23600,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -23634,8 +23634,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -23668,8 +23668,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -23702,8 +23702,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -23736,8 +23736,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -23770,8 +23770,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -23804,8 +23804,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -23838,8 +23838,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -23872,8 +23872,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -23906,8 +23906,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -23940,8 +23940,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -23974,8 +23974,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -24008,8 +24008,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -24042,8 +24042,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -24076,8 +24076,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -24110,8 +24110,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -24144,8 +24144,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -24178,8 +24178,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -24212,8 +24212,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -24246,8 +24246,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -24280,8 +24280,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -24314,8 +24314,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -24348,8 +24348,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -24382,8 +24382,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -24416,8 +24416,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -24450,8 +24450,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -24484,8 +24484,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -24518,8 +24518,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -24552,8 +24552,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -24586,8 +24586,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -24620,8 +24620,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -24654,8 +24654,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -24688,8 +24688,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -24722,8 +24722,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -24756,8 +24756,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -24790,8 +24790,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -24824,8 +24824,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -24858,8 +24858,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -24892,8 +24892,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -24926,8 +24926,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -24960,8 +24960,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -24994,8 +24994,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.06, "hr_2": 0.06, @@ -25028,8 +25028,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.06, "hr_2": 0.06, @@ -25062,8 +25062,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.06, "hr_2": 0.06, @@ -25096,8 +25096,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.25, "hr_2": 0.25, @@ -25130,8 +25130,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.25, "hr_2": 0.25, @@ -25164,8 +25164,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.25, "hr_2": 0.25, @@ -25198,8 +25198,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -25232,8 +25232,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -25266,8 +25266,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -25300,8 +25300,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -25334,8 +25334,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -25368,8 +25368,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -25402,8 +25402,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -25436,8 +25436,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -25470,8 +25470,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -25504,8 +25504,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -25538,8 +25538,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -25572,8 +25572,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -25606,8 +25606,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -25640,8 +25640,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -25674,8 +25674,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -25708,8 +25708,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -25742,8 +25742,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -25776,8 +25776,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -25810,8 +25810,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -25844,8 +25844,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -25878,8 +25878,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -25912,8 +25912,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -25946,8 +25946,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -25980,8 +25980,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -26014,8 +26014,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -26048,8 +26048,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -26082,8 +26082,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -26116,8 +26116,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -26150,8 +26150,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -26184,8 +26184,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -26218,8 +26218,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -26252,8 +26252,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -26286,8 +26286,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.05, "hr_2": 0.05, @@ -26320,8 +26320,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.25, "hr_2": 0.25, @@ -26354,8 +26354,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.25, "hr_2": 0.25, @@ -26388,8 +26388,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.25, "hr_2": 0.25, @@ -26422,8 +26422,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -26456,8 +26456,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -26490,8 +26490,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -26524,8 +26524,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -26558,8 +26558,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -26592,8 +26592,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -26626,8 +26626,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.25, "hr_2": 0.25, @@ -26660,8 +26660,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.25, "hr_2": 0.25, @@ -26694,8 +26694,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.25, "hr_2": 0.25, @@ -26728,8 +26728,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -26762,8 +26762,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -26796,8 +26796,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -26830,8 +26830,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -26864,8 +26864,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -26898,8 +26898,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.9, "hr_2": 0.9, @@ -26932,8 +26932,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -26966,8 +26966,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -27000,8 +27000,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -27034,8 +27034,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -27068,8 +27068,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -27102,8 +27102,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -27136,8 +27136,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.25, "hr_2": 0.25, @@ -27170,8 +27170,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.25, "hr_2": 0.25, @@ -27204,8 +27204,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0.25, "hr_2": 0.25, @@ -27238,8 +27238,8 @@ "category": "Occupancy", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -27272,8 +27272,8 @@ "category": "Occupancy", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -27306,8 +27306,8 @@ "category": "Occupancy", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -27340,8 +27340,8 @@ "category": "Lighting", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -27374,8 +27374,8 @@ "category": "Lighting", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -27408,8 +27408,8 @@ "category": "Lighting", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -27442,8 +27442,8 @@ "category": "Equipment", "units": null, "day_types": "Default|SmrDsn|Wkdy", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -27476,8 +27476,8 @@ "category": "Equipment", "units": null, "day_types": "Sat", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, @@ -27510,8 +27510,8 @@ "category": "Equipment", "units": null, "day_types": "WntrDsn|Hol|Sun", - "start_date": "1-Jan", - "end_date": "31-Dec", + "start_date": "1/1/2023", + "end_date": "12/31/2023", "type": "Hourly", "hr_1": 0, "hr_2": 0, diff --git a/data/openstudio_standards_data/database_tables/__init__.py b/data/openstudio_standards_data/database_tables/__init__.py index 598d9e27bc..7fc4530a41 100644 --- a/data/openstudio_standards_data/database_tables/__init__.py +++ b/data/openstudio_standards_data/database_tables/__init__.py @@ -34,6 +34,7 @@ "level_3_ventilation_62_1_2004", "level_3_ventilation_62_1_1999", "level_2_electric_equipment", + "level_2_natural_gas_equipment", "support_lighting_technologies", "support_standard_templates", "support_lighting_space_type_name_tags", diff --git a/data/openstudio_standards_data/database_tables/level_2_natural_gas_equipment.py b/data/openstudio_standards_data/database_tables/level_2_natural_gas_equipment.py index 6e6620568b..65beef817d 100644 --- a/data/openstudio_standards_data/database_tables/level_2_natural_gas_equipment.py +++ b/data/openstudio_standards_data/database_tables/level_2_natural_gas_equipment.py @@ -73,6 +73,7 @@ def validate_record_datatype(self, record): assert is_float( record.get(f) ), f"{f} requires to be numeric data type, instead got {record[f]}" + return True def _preprocess_record(self, record): """ diff --git a/data/openstudio_standards_data/query/fetch/space.py b/data/openstudio_standards_data/query/fetch/space.py index 771bc58218..6e912661b3 100644 --- a/data/openstudio_standards_data/query/fetch/space.py +++ b/data/openstudio_standards_data/query/fetch/space.py @@ -7,24 +7,30 @@ from query.util import _convert_list_tuple_to_list_dict SPACE_DATA_HEADER = [ - "space_type", - "lighting_space_type_name", - "ventilation_space_type_name", - "level_3_lighting_code_definition_table", - "level_3_lighting_code_definition_id", - "level_3_ventilation_definition_table", - "level_3_ventilation_definition_id", - "electric_equipment_space_type_name", + "space_type_name", + "BS.lighting_space_type_name", + "BS.ventilation_space_type_name", + "LS.level_3_lighting_code_definition_table", + "LS.level_3_lighting_code_definition_id", + "VS.level_3_ventilation_definition_table", + "VS.level_3_ventilation_definition_id", + "ES.electric_equipment_space_type_name", + "EGS.natural_gas_equipment_space_type_name", + "BS.schedule_set_name", ] SPACE_JOIN_QUERY = f""" SELECT {','.join(SPACE_DATA_HEADER)} FROM level_1_space_types as BS - LEFT JOIN light_subspaces as LS + LEFT JOIN level_2_lighting_space_types as LS ON BS.lighting_space_type_name = LS.lighting_space_type_name - LEFT JOIN vent_subspaces as VS + LEFT JOIN level_2_ventilation_space_types as VS ON BS.ventilation_space_type_name = VS.ventilation_space_type_name + LEFT JOIN level_2_electric_equipment as ES + ON BS.electric_equipment_space_type_name = ES.electric_equipment_space_type_name + LEFT JOIN level_2_natural_gas_equipment as EGS + ON BS.natural_gas_equipment_space_type_name = EGS.natural_gas_equipment_space_type_name """ From 535456f81229087436bbdc06c987b03a155d11c5 Mon Sep 17 00:00:00 2001 From: Jeremy L <5149279+lymereJ@users.noreply.github.com> Date: Thu, 30 Mar 2023 21:41:40 -0700 Subject: [PATCH 18/45] Data refactoring miscellaneous clean up (#1483) * Misc cleanup * Black formatting * Update JSON files. * Level 1 space type cleanup, add datacenter equipment assumptions. * Add missing tag. * Add missing tag. --- .../create_openstudio_standards_json.py | 23 + .../database_files/level_1_space_types.csv | 126 +- .../database_files/level_1_space_types.json | 223 +- .../level_2_electric_equipment.csv | 190 +- .../level_2_electric_equipment.json | 487 +++- .../level_2_lighting_space_types.csv | 1418 +++++------ .../level_2_lighting_space_types.json | 2124 +++++++++++------ .../level_2_natural_gas_equipment.csv | 14 +- .../level_2_natural_gas_equipment.json | 32 +- .../level_3_lighting_90_1_2016.csv | 22 +- .../level_3_lighting_90_1_2016.json | 24 +- .../level_3_ventilation_62_1_2007.csv | 2 +- .../level_3_ventilation_62_1_2007.json | 2 +- .../level_3_ventilation_62_1_2010.csv | 2 +- .../level_3_ventilation_62_1_2010.json | 2 +- .../level_3_ventilation_62_1_2013.csv | 4 +- .../level_3_ventilation_62_1_2013.json | 4 +- .../level_3_ventilation_62_1_2016.csv | 4 +- .../level_3_ventilation_62_1_2016.json | 4 +- .../level_3_ventilation_62_1_2019.csv | 2 +- .../level_3_ventilation_62_1_2019.json | 2 +- ...lectric_equipment_space_type_name_tags.csv | 2 + ...ectric_equipment_space_type_name_tags.json | 6 + .../database_tables/level_1_space_types.py | 9 +- .../level_2_electric_equipment.py | 54 +- .../level_2_lighting_space_types.py | 8 +- .../level_2_natural_gas_equipment.py | 40 +- .../standards/Standards.SpaceType.rb | 3 + test/doe_prototype/test_medium_office.rb | 4 +- 29 files changed, 3002 insertions(+), 1835 deletions(-) diff --git a/data/openstudio_standards_data/applications/create_openstudio_standards_json.py b/data/openstudio_standards_data/applications/create_openstudio_standards_json.py index 067d45f82a..429e403e7b 100644 --- a/data/openstudio_standards_data/applications/create_openstudio_standards_json.py +++ b/data/openstudio_standards_data/applications/create_openstudio_standards_json.py @@ -177,6 +177,11 @@ def create_openstudio_standards_space_data_json( "electric_equipment_space_type_name": electric_equipment_space_type_name }, ) + equipment_tech_fields = [ + "electric_equipment_fraction_latent", + "electric_equipment_fraction_radiant", + "electric_equipment_fraction_lost", + ] if isinstance(electric_equipment_space_type_data, list): if len(electric_equipment_space_type_data) > 0: space_type_data["electric_equipment_per_area"] = float( @@ -184,10 +189,17 @@ def create_openstudio_standards_space_data_json( "electric_equipment_average_epd" ] ) + for f in equipment_tech_fields: + space_type_data[f] = electric_equipment_space_type_data[0][f] else: space_type_data["electric_equipment_per_area"] = 0.0 + for f in equipment_tech_fields: + space_type_data[f] = 0.0 else: space_type_data["electric_equipment_per_area"] = 0.0 + space_type_data["electric_equipment_per_area"] = 0.0 + for f in equipment_tech_fields: + space_type_data[f] = 0.0 natural_gas_equipment_space_type_name = space_type_infos[ "EGS.natural_gas_equipment_space_type_name" @@ -199,6 +211,11 @@ def create_openstudio_standards_space_data_json( "natural_gas_equipment_space_type_name": natural_gas_equipment_space_type_name }, ) + equipment_tech_fields = [ + "natural_gas_equipment_fraction_latent", + "natural_gas_equipment_fraction_radiant", + "natural_gas_equipment_fraction_lost", + ] if isinstance(natural_gas_equipment_space_type_data, list): if len(natural_gas_equipment_space_type_data) > 0: space_type_data["natural_gas_equipment_per_area"] = float( @@ -206,10 +223,16 @@ def create_openstudio_standards_space_data_json( "natural_gas_equipment_average_epd" ] ) + for f in equipment_tech_fields: + space_type_data[f] = natural_gas_equipment_space_type_data[0][f] else: space_type_data["natural_gas_equipment_per_area"] = 0.0 + for f in equipment_tech_fields: + space_type_data[f] = 0.0 else: space_type_data["natural_gas_equipment_per_area"] = 0.0 + for f in equipment_tech_fields: + space_type_data[f] = 0.0 # Get ventilation and occupancy space type data ventilation_space_type_name = space_type_infos[ diff --git a/data/openstudio_standards_data/database_files/level_1_space_types.csv b/data/openstudio_standards_data/database_files/level_1_space_types.csv index e87d8506c9..6a3389fe68 100644 --- a/data/openstudio_standards_data/database_files/level_1_space_types.csv +++ b/data/openstudio_standards_data/database_files/level_1_space_types.csv @@ -1,64 +1,62 @@ -space_type_name,lighting_space_type_name,ventilation_space_type_name,electric_equipment_space_type_name,natural_gas_equipment_space_type_name,schedule_set_name -airport concourse,airport_concourse_lighting,airport_concourse_ventilation,airport_concourse_electric_equipment,,airport_concourse -atrium,atrium_lighting,atrium_ventilation,atrium_lt_20_ft_height_electric_equipment,,atrium_lt_20_ft_height -attic,none_lighting,attic_ventilation,attic_electric_equipment,,attic -audience seating,audience_seating_lighting,audience_seating_ventilation,audience_seating_all_other_electric_equipment,,audience_seating_all_other -baggage/carousel,baggage_carousel_lighting,baggage_carousel_ventilation,baggage_carousel_electric_equipment,,baggage_carousel -banking,banking_lighting,banking_ventilation,banking_activity_electric_equipment,,banking_activity -classroom/lecture/training,classroom_lecture_training_lighting,classroom_lecture_training_ventilation,classroom_lecture_training_all_other_electric_equipment,,classroom_lecture_training_all_other -computer room,computer_room_lighting,computer_room_ventilation,computer_room_electric_equipment,,computer_room -conference/meeting/multipurpose,conference_meeting_multipurpose_lighting,conference_meeting_multipurpose_ventilation,conference_meeting_multipurpose_electric_equipment,,conference_meeting_multipurpose -confinement cells,confinement_cells_lighting,confinement_cells_ventilation,confinement_cells_electric_equipment,,confinement_cells -copy/print,copy_print_lighting,copy_print_ventilation,,, -corridor,corridor_lighting,corridor_ventilation,corridor_all_other_electric_equipment,,corridor_all_other -courtroom,courtroom_lighting,courtroom_ventilation,courtroom_electric_equipment,,courtroom -datacenterHighITE,datacenterhighite_lighting,datacenterhighite_ventilation,,, -datacenterLowITE,datacenterlowite_lighting,datacenterlowite_ventilation,,, -dining,dining_lighting,dining_ventilation,dining_all_other_electric_equipment,,dining_all_other -dressing room,dressing_room_lighting,dressing_room_ventilation,performing_arts_dressing_room_electric_equipment,,performing_arts_dressing_room -electrical/mechanical,electrical_mechanical_lighting,electrical_mechanical_ventilation,electrical_mechanical_electric_equipment,,electrical_mechanical -emergency room,emergency_room_lighting,emergency_room_ventilation,emergency_room_electric_equipment,,emergency_room -emergency vehicle garage,emergency_vehicle_garage_lighting,emergency_vehicle_garage_ventilation,emergency_vehicle_garage_electric_equipment,,emergency_vehicle_garage -exam/treatment,exam_treatment_lighting,exam_treatment_ventilation,exam_treatment_electric_equipment,,exam_treatment -exercise area,exercise_area_lighting,exercise_area_ventilation,gymnasium_exercise_area_electric_equipment,,gymnasium_exercise_area -exhibit,exhibit_lighting,exhibit_ventilation,museum_exhibit_area_electric_equipment,,museum_exhibit_area -guest room,guest_room_lighting,guest_room_ventilation,guest_room_electric_equipment,,guest_room -imaging,imaging_lighting,imaging_ventilation,,, -interior parking,interior_parking_lighting,interior_parking_ventilation,parking_area_interior_electric_equipment,,parking_area_interior -judges chambers,judges_chambers_lighting,judges_chambers_ventilation,judges_chambers_electric_equipment,,judges_chambers -food preparation,food_preparation_lighting,food_preparation_ventilation,kitchen_electric_equipment,kitchen,kitchen -laboratory,laboratory_lighting,laboratory_ventilation,laboratory_electric_equipment,,laboratory -laundry/washing,laundry_washing_lighting,laundry_washing_ventilation,laundry_washing_electric_equipment,laundry,laundry_washing -library,library_lighting,library_ventilation,library_stacks_electric_equipment,,library_stacks -living quarters,living_quarters_lighting,living_quarters_ventilation,dormitory_living_quarters_electric_equipment,,dormitory_living_quarters -loading dock,loading_dock_lighting,loading_dock_ventilation,,, -lobby,lobby_lighting,lobby_ventilation,lobby_all_other_electric_equipment,,lobby_all_other -locker room,locker_room_lighting,locker_room_ventilation,locker_room_electric_equipment,,locker_room -lounge/breakroom,lounge_breakroom_lighting,lounge_breakroom_ventilation,lounge_breakroom_all_other_electric_equipment,,lounge_breakroom_all_other -manufacturing,manufacturing_lighting,manufacturing_ventilation,manufacturing_low_bay_electric_equipment,,manufacturing_low_bay -medical supply,medical_supply_lighting,medical_supply_ventilation,pharmacy_electric_equipment,,pharmacy -multifamily,multifamily_lighting,multifamily_ventilation,,, -nursery,nursery_lighting,nursery_ventilation,patient_room_electric_equipment,,patient_room -nurses station,nurses_station_lighting,nurses_station_ventilation,nurses_station_electric_equipment,,nurses_station -office,office_lighting,office_ventilation,office_open_electric_equipment,,office_open -"office, enclosed",office_enclosed_lighting,office_enclosed_ventilation,office_enclosed_lte_250_sf_electric_equipment,,office_enclosed_lte_250_sf -operating room,operating_room_lighting,operating_room_ventilation,operating_room_electric_equipment,,operating_room -patient room,patient_room_lighting,patient_room_ventilation,patient_room_electric_equipment,,patient_room -pharmacy,pharmacy_lighting,pharmacy_ventilation,pharmacy_electric_equipment,,pharmacy -physical therapy,physical_therapy_lighting,physical_therapy_ventilation,physical_therapy_electric_equipment,,physical_therapy -playing area,playing_area_lighting,playing_area_ventilation,gymnasium_playing_area_electric_equipment,,gymnasium_playing_area -plenum,none_lighting,plenum_ventilation,plenum_electric_equipment,,plenum -post office,post_office_lighting,post_office_ventilation,post_office_sorting_area_electric_equipment,,post_office_sorting_area -recovery,recovery_lighting,recovery_ventilation,patient_room_electric_equipment,,patient_room -recreation/common living,recreation_common_living_lighting,recreation_common_living_ventilation,lounge_breakroom_all_other_electric_equipment,,lounge_breakroom_all_other -restroom,restroom_lighting,restroom_ventilation,restroom_all_other_electric_equipment,,restroom_all_other -retail,retail_sales_lighting,retail_sales_ventilation,sales_electric_equipment,,sales -shaft,none_lighting,shaft_ventilation,shaft_electric_equipment,,shaft -sleeping quarters,sleeping_quarters_lighting,sleeping_quarters_ventilation,firestation_sleeping_quarters_electric_equipment,,firestation_sleeping_quarters -sports arena,sports_arena_lighting,sports_arena_ventilation,sports_arena_playing_area_class_ii_electric_equipment,,sports_arena_playing_area_class_ii -stairwell,stairwell_lighting,stairwell_ventilation,stairwell_electric_equipment,,stairwell -storage,storage_lighting,storage_ventilation,storage_50_to_1000_sf_all_other_electric_equipment,,storage_50_to_1000_sf_all_other -transportation,transportation_lighting,transportation_ventilation,transportation_ticket_counter_electric_equipment,,transportation_ticket_counter -vehicular maintenance,vehicular_maintenance_lighting,vehicular_maintenance_ventilation,vehicular_maintenance_electric_equipment,,vehicular_maintenance -workshop,workshop_lighting,workshop_ventilation,workshop_electric_equipment,,workshop -worship,worship_lighting,worship_ventilation,worship_pulpit_choir_area_electric_equipment,,worship_pulpit_choir_area +space_type_name,lighting_space_type_name,ventilation_space_type_name,electric_equipment_space_type_name,natural_gas_equipment_space_type_name,schedule_set_name,annotation +atrium,atrium_lighting,atrium_ventilation,atrium_lt_20_ft_height_electric_equipment,,atrium_lt_20_ft_height, +attic,none_lighting,attic_ventilation,attic_electric_equipment,,attic, +audience seating,audience_seating_lighting,audience_seating_ventilation,audience_seating_all_other_electric_equipment,,audience_seating_all_other, +banking,banking_lighting,banking_ventilation,banking_activity_electric_equipment,,banking_activity, +"classroom, lecture, training",classroom_lecture_training_lighting,classroom_lecture_training_ventilation,classroom_lecture_training_all_other_electric_equipment,,classroom_lecture_training_all_other, +computer room,computer_room_lighting,computer_room_ventilation,computer_room_electric_equipment,,computer_room, +"conference, meeting, multipurpose",conference_meeting_multipurpose_lighting,conference_meeting_multipurpose_ventilation,conference_meeting_multipurpose_electric_equipment,,conference_meeting_multipurpose, +confinement cells,confinement_cells_lighting,confinement_cells_ventilation,confinement_cells_electric_equipment,,confinement_cells, +"copy, print",copy_print_lighting,copy_print_ventilation,,,, +corridor,corridor_lighting,corridor_ventilation,corridor_all_other_electric_equipment,,corridor_all_other, +courtroom,courtroom_lighting,courtroom_ventilation,courtroom_electric_equipment,,courtroom, +"datacenter, high ite",datacenterhighite_lighting,datacenterhighite_ventilation,datacenter_high_ite_equipment,,, +"datacenter, low ite",datacenterlowite_lighting,datacenterlowite_ventilation,datacenter_low_ite_equipment,,, +dining,dining_lighting,dining_ventilation,dining_all_other_electric_equipment,,dining_all_other, +dressing room,dressing_room_lighting,dressing_room_ventilation,performing_arts_dressing_room_electric_equipment,,performing_arts_dressing_room, +"electrical, mechanical",electrical_mechanical_lighting,electrical_mechanical_ventilation,electrical_mechanical_electric_equipment,,electrical_mechanical, +emergency room,emergency_room_lighting,emergency_room_ventilation,emergency_room_electric_equipment,,emergency_room, +emergency vehicle garage,emergency_vehicle_garage_lighting,emergency_vehicle_garage_ventilation,emergency_vehicle_garage_electric_equipment,,emergency_vehicle_garage, +"exam, treatment",exam_treatment_lighting,exam_treatment_ventilation,exam_treatment_electric_equipment,,exam_treatment, +exercise area,exercise_area_lighting,exercise_area_ventilation,gymnasium_exercise_area_electric_equipment,,gymnasium_exercise_area, +exhibit,exhibit_lighting,exhibit_ventilation,museum_exhibit_area_electric_equipment,,museum_exhibit_area, +guest room,guest_room_lighting,guest_room_ventilation,guest_room_electric_equipment,,guest_room, +imaging,imaging_lighting,imaging_ventilation,,,, +interior parking,interior_parking_lighting,interior_parking_ventilation,parking_area_interior_electric_equipment,,parking_area_interior, +judges chambers,judges_chambers_lighting,judges_chambers_ventilation,judges_chambers_electric_equipment,,judges_chambers, +food preparation,food_preparation_lighting,food_preparation_ventilation,kitchen_electric_equipment,kitchen,kitchen, +laboratory,laboratory_lighting,laboratory_ventilation,laboratory_electric_equipment,,laboratory, +"laundry, washing",laundry_washing_lighting,laundry_washing_ventilation,laundry_washing_electric_equipment,laundry,laundry_washing, +library,library_lighting,library_ventilation,library_stacks_electric_equipment,,library_stacks, +living quarters,living_quarters_lighting,living_quarters_ventilation,dormitory_living_quarters_electric_equipment,,dormitory_living_quarters,living quarters such as in a fire station +loading dock,loading_dock_lighting,loading_dock_ventilation,,,, +lobby,lobby_lighting,lobby_ventilation,lobby_all_other_electric_equipment,,lobby_all_other, +locker room,locker_room_lighting,locker_room_ventilation,locker_room_electric_equipment,,locker_room, +"lounge, breakroom",lounge_breakroom_lighting,lounge_breakroom_ventilation,lounge_breakroom_all_other_electric_equipment,,lounge_breakroom_all_other, +manufacturing,manufacturing_lighting,manufacturing_ventilation,manufacturing_low_bay_electric_equipment,,manufacturing_low_bay, +medical supply,medical_supply_lighting,medical_supply_ventilation,pharmacy_electric_equipment,,pharmacy, +multifamily,multifamily_lighting,multifamily_ventilation,,,,"common areas in a multifamily building, NOT dwelling units" +nursery,nursery_lighting,nursery_ventilation,patient_room_electric_equipment,,patient_room, +nurses station,nurses_station_lighting,nurses_station_ventilation,nurses_station_electric_equipment,,nurses_station, +office,office_lighting,office_ventilation,office_open_electric_equipment,,office_open, +"office, enclosed",office_enclosed_lighting,office_enclosed_ventilation,office_enclosed_lte_250_sf_electric_equipment,,office_enclosed_lte_250_sf, +operating room,operating_room_lighting,operating_room_ventilation,operating_room_electric_equipment,,operating_room, +patient room,patient_room_lighting,patient_room_ventilation,patient_room_electric_equipment,,patient_room, +pharmacy,pharmacy_lighting,pharmacy_ventilation,pharmacy_electric_equipment,,pharmacy, +physical therapy,physical_therapy_lighting,physical_therapy_ventilation,physical_therapy_electric_equipment,,physical_therapy, +playing area,playing_area_lighting,playing_area_ventilation,gymnasium_playing_area_electric_equipment,,gymnasium_playing_area, +plenum,none_lighting,plenum_ventilation,plenum_electric_equipment,,plenum, +post office,post_office_lighting,post_office_ventilation,post_office_sorting_area_electric_equipment,,post_office_sorting_area, +recovery,recovery_lighting,recovery_ventilation,patient_room_electric_equipment,,patient_room, +"recreation, common living",recreation_common_living_lighting,recreation_common_living_ventilation,lounge_breakroom_all_other_electric_equipment,,lounge_breakroom_all_other, +restroom,restroom_lighting,restroom_ventilation,restroom_all_other_electric_equipment,,restroom_all_other, +retail,retail_sales_lighting,retail_sales_ventilation,sales_electric_equipment,,sales, +shaft,none_lighting,shaft_ventilation,shaft_electric_equipment,,shaft, +sleeping quarters,sleeping_quarters_lighting,sleeping_quarters_ventilation,firestation_sleeping_quarters_electric_equipment,,firestation_sleeping_quarters,sleeping quarters such as in a dormitory +sports arena,sports_arena_lighting,sports_arena_ventilation,sports_arena_playing_area_class_ii_electric_equipment,,sports_arena_playing_area_class_ii, +stairwell,stairwell_lighting,stairwell_ventilation,stairwell_electric_equipment,,stairwell, +storage,storage_lighting,storage_ventilation,storage_50_to_1000_sf_all_other_electric_equipment,,storage_50_to_1000_sf_all_other, +transportation,transportation_lighting,transportation_ventilation,transportation_ticket_counter_electric_equipment,,transportation_ticket_counter, +vehicular maintenance,vehicular_maintenance_lighting,vehicular_maintenance_ventilation,vehicular_maintenance_electric_equipment,,vehicular_maintenance, +workshop,workshop_lighting,workshop_ventilation,workshop_electric_equipment,,workshop, +worship,worship_lighting,worship_ventilation,worship_pulpit_choir_area_electric_equipment,,worship_pulpit_choir_area, diff --git a/data/openstudio_standards_data/database_files/level_1_space_types.json b/data/openstudio_standards_data/database_files/level_1_space_types.json index 570d8c86ca..83606a7e31 100644 --- a/data/openstudio_standards_data/database_files/level_1_space_types.json +++ b/data/openstudio_standards_data/database_files/level_1_space_types.json @@ -1,19 +1,12 @@ [ - { - "space_type_name": "airport concourse", - "lighting_space_type_name": "airport_concourse_lighting", - "ventilation_space_type_name": "airport_concourse_ventilation", - "electric_equipment_space_type_name": "airport_concourse_electric_equipment", - "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "airport_concourse" - }, { "space_type_name": "atrium", "lighting_space_type_name": "atrium_lighting", "ventilation_space_type_name": "atrium_ventilation", "electric_equipment_space_type_name": "atrium_lt_20_ft_height_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "atrium_lt_20_ft_height" + "schedule_set_name": "atrium_lt_20_ft_height", + "annotation": null }, { "space_type_name": "attic", @@ -21,7 +14,8 @@ "ventilation_space_type_name": "attic_ventilation", "electric_equipment_space_type_name": "attic_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "attic" + "schedule_set_name": "attic", + "annotation": null }, { "space_type_name": "audience seating", @@ -29,15 +23,8 @@ "ventilation_space_type_name": "audience_seating_ventilation", "electric_equipment_space_type_name": "audience_seating_all_other_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "audience_seating_all_other" - }, - { - "space_type_name": "baggage/carousel", - "lighting_space_type_name": "baggage_carousel_lighting", - "ventilation_space_type_name": "baggage_carousel_ventilation", - "electric_equipment_space_type_name": "baggage_carousel_electric_equipment", - "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "baggage_carousel" + "schedule_set_name": "audience_seating_all_other", + "annotation": null }, { "space_type_name": "banking", @@ -45,15 +32,17 @@ "ventilation_space_type_name": "banking_ventilation", "electric_equipment_space_type_name": "banking_activity_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "banking_activity" + "schedule_set_name": "banking_activity", + "annotation": null }, { - "space_type_name": "classroom/lecture/training", + "space_type_name": "classroom, lecture, training", "lighting_space_type_name": "classroom_lecture_training_lighting", "ventilation_space_type_name": "classroom_lecture_training_ventilation", "electric_equipment_space_type_name": "classroom_lecture_training_all_other_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "classroom_lecture_training_all_other" + "schedule_set_name": "classroom_lecture_training_all_other", + "annotation": null }, { "space_type_name": "computer room", @@ -61,15 +50,17 @@ "ventilation_space_type_name": "computer_room_ventilation", "electric_equipment_space_type_name": "computer_room_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "computer_room" + "schedule_set_name": "computer_room", + "annotation": null }, { - "space_type_name": "conference/meeting/multipurpose", + "space_type_name": "conference, meeting, multipurpose", "lighting_space_type_name": "conference_meeting_multipurpose_lighting", "ventilation_space_type_name": "conference_meeting_multipurpose_ventilation", "electric_equipment_space_type_name": "conference_meeting_multipurpose_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "conference_meeting_multipurpose" + "schedule_set_name": "conference_meeting_multipurpose", + "annotation": null }, { "space_type_name": "confinement cells", @@ -77,15 +68,17 @@ "ventilation_space_type_name": "confinement_cells_ventilation", "electric_equipment_space_type_name": "confinement_cells_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "confinement_cells" + "schedule_set_name": "confinement_cells", + "annotation": null }, { - "space_type_name": "copy/print", + "space_type_name": "copy, print", "lighting_space_type_name": "copy_print_lighting", "ventilation_space_type_name": "copy_print_ventilation", "electric_equipment_space_type_name": null, "natural_gas_equipment_space_type_name": null, - "schedule_set_name": null + "schedule_set_name": null, + "annotation": null }, { "space_type_name": "corridor", @@ -93,7 +86,8 @@ "ventilation_space_type_name": "corridor_ventilation", "electric_equipment_space_type_name": "corridor_all_other_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "corridor_all_other" + "schedule_set_name": "corridor_all_other", + "annotation": null }, { "space_type_name": "courtroom", @@ -101,23 +95,26 @@ "ventilation_space_type_name": "courtroom_ventilation", "electric_equipment_space_type_name": "courtroom_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "courtroom" + "schedule_set_name": "courtroom", + "annotation": null }, { - "space_type_name": "datacenterHighITE", + "space_type_name": "datacenter, high ite", "lighting_space_type_name": "datacenterhighite_lighting", "ventilation_space_type_name": "datacenterhighite_ventilation", - "electric_equipment_space_type_name": null, + "electric_equipment_space_type_name": "datacenter_high_ite_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": null + "schedule_set_name": null, + "annotation": null }, { - "space_type_name": "datacenterLowITE", + "space_type_name": "datacenter, low ite", "lighting_space_type_name": "datacenterlowite_lighting", "ventilation_space_type_name": "datacenterlowite_ventilation", - "electric_equipment_space_type_name": null, + "electric_equipment_space_type_name": "datacenter_low_ite_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": null + "schedule_set_name": null, + "annotation": null }, { "space_type_name": "dining", @@ -125,7 +122,8 @@ "ventilation_space_type_name": "dining_ventilation", "electric_equipment_space_type_name": "dining_all_other_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "dining_all_other" + "schedule_set_name": "dining_all_other", + "annotation": null }, { "space_type_name": "dressing room", @@ -133,15 +131,17 @@ "ventilation_space_type_name": "dressing_room_ventilation", "electric_equipment_space_type_name": "performing_arts_dressing_room_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "performing_arts_dressing_room" + "schedule_set_name": "performing_arts_dressing_room", + "annotation": null }, { - "space_type_name": "electrical/mechanical", + "space_type_name": "electrical, mechanical", "lighting_space_type_name": "electrical_mechanical_lighting", "ventilation_space_type_name": "electrical_mechanical_ventilation", "electric_equipment_space_type_name": "electrical_mechanical_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "electrical_mechanical" + "schedule_set_name": "electrical_mechanical", + "annotation": null }, { "space_type_name": "emergency room", @@ -149,7 +149,8 @@ "ventilation_space_type_name": "emergency_room_ventilation", "electric_equipment_space_type_name": "emergency_room_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "emergency_room" + "schedule_set_name": "emergency_room", + "annotation": null }, { "space_type_name": "emergency vehicle garage", @@ -157,15 +158,17 @@ "ventilation_space_type_name": "emergency_vehicle_garage_ventilation", "electric_equipment_space_type_name": "emergency_vehicle_garage_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "emergency_vehicle_garage" + "schedule_set_name": "emergency_vehicle_garage", + "annotation": null }, { - "space_type_name": "exam/treatment", + "space_type_name": "exam, treatment", "lighting_space_type_name": "exam_treatment_lighting", "ventilation_space_type_name": "exam_treatment_ventilation", "electric_equipment_space_type_name": "exam_treatment_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "exam_treatment" + "schedule_set_name": "exam_treatment", + "annotation": null }, { "space_type_name": "exercise area", @@ -173,7 +176,8 @@ "ventilation_space_type_name": "exercise_area_ventilation", "electric_equipment_space_type_name": "gymnasium_exercise_area_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "gymnasium_exercise_area" + "schedule_set_name": "gymnasium_exercise_area", + "annotation": null }, { "space_type_name": "exhibit", @@ -181,7 +185,8 @@ "ventilation_space_type_name": "exhibit_ventilation", "electric_equipment_space_type_name": "museum_exhibit_area_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "museum_exhibit_area" + "schedule_set_name": "museum_exhibit_area", + "annotation": null }, { "space_type_name": "guest room", @@ -189,7 +194,8 @@ "ventilation_space_type_name": "guest_room_ventilation", "electric_equipment_space_type_name": "guest_room_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "guest_room" + "schedule_set_name": "guest_room", + "annotation": null }, { "space_type_name": "imaging", @@ -197,7 +203,8 @@ "ventilation_space_type_name": "imaging_ventilation", "electric_equipment_space_type_name": null, "natural_gas_equipment_space_type_name": null, - "schedule_set_name": null + "schedule_set_name": null, + "annotation": null }, { "space_type_name": "interior parking", @@ -205,7 +212,8 @@ "ventilation_space_type_name": "interior_parking_ventilation", "electric_equipment_space_type_name": "parking_area_interior_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "parking_area_interior" + "schedule_set_name": "parking_area_interior", + "annotation": null }, { "space_type_name": "judges chambers", @@ -213,7 +221,8 @@ "ventilation_space_type_name": "judges_chambers_ventilation", "electric_equipment_space_type_name": "judges_chambers_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "judges_chambers" + "schedule_set_name": "judges_chambers", + "annotation": null }, { "space_type_name": "food preparation", @@ -221,7 +230,8 @@ "ventilation_space_type_name": "food_preparation_ventilation", "electric_equipment_space_type_name": "kitchen_electric_equipment", "natural_gas_equipment_space_type_name": "kitchen", - "schedule_set_name": "kitchen" + "schedule_set_name": "kitchen", + "annotation": null }, { "space_type_name": "laboratory", @@ -229,15 +239,17 @@ "ventilation_space_type_name": "laboratory_ventilation", "electric_equipment_space_type_name": "laboratory_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "laboratory" + "schedule_set_name": "laboratory", + "annotation": null }, { - "space_type_name": "laundry/washing", + "space_type_name": "laundry, washing", "lighting_space_type_name": "laundry_washing_lighting", "ventilation_space_type_name": "laundry_washing_ventilation", "electric_equipment_space_type_name": "laundry_washing_electric_equipment", "natural_gas_equipment_space_type_name": "laundry", - "schedule_set_name": "laundry_washing" + "schedule_set_name": "laundry_washing", + "annotation": null }, { "space_type_name": "library", @@ -245,7 +257,8 @@ "ventilation_space_type_name": "library_ventilation", "electric_equipment_space_type_name": "library_stacks_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "library_stacks" + "schedule_set_name": "library_stacks", + "annotation": null }, { "space_type_name": "living quarters", @@ -253,7 +266,8 @@ "ventilation_space_type_name": "living_quarters_ventilation", "electric_equipment_space_type_name": "dormitory_living_quarters_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "dormitory_living_quarters" + "schedule_set_name": "dormitory_living_quarters", + "annotation": "living quarters such as in a fire station" }, { "space_type_name": "loading dock", @@ -261,7 +275,8 @@ "ventilation_space_type_name": "loading_dock_ventilation", "electric_equipment_space_type_name": null, "natural_gas_equipment_space_type_name": null, - "schedule_set_name": null + "schedule_set_name": null, + "annotation": null }, { "space_type_name": "lobby", @@ -269,7 +284,8 @@ "ventilation_space_type_name": "lobby_ventilation", "electric_equipment_space_type_name": "lobby_all_other_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "lobby_all_other" + "schedule_set_name": "lobby_all_other", + "annotation": null }, { "space_type_name": "locker room", @@ -277,15 +293,17 @@ "ventilation_space_type_name": "locker_room_ventilation", "electric_equipment_space_type_name": "locker_room_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "locker_room" + "schedule_set_name": "locker_room", + "annotation": null }, { - "space_type_name": "lounge/breakroom", + "space_type_name": "lounge, breakroom", "lighting_space_type_name": "lounge_breakroom_lighting", "ventilation_space_type_name": "lounge_breakroom_ventilation", "electric_equipment_space_type_name": "lounge_breakroom_all_other_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "lounge_breakroom_all_other" + "schedule_set_name": "lounge_breakroom_all_other", + "annotation": null }, { "space_type_name": "manufacturing", @@ -293,7 +311,8 @@ "ventilation_space_type_name": "manufacturing_ventilation", "electric_equipment_space_type_name": "manufacturing_low_bay_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "manufacturing_low_bay" + "schedule_set_name": "manufacturing_low_bay", + "annotation": null }, { "space_type_name": "medical supply", @@ -301,7 +320,8 @@ "ventilation_space_type_name": "medical_supply_ventilation", "electric_equipment_space_type_name": "pharmacy_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "pharmacy" + "schedule_set_name": "pharmacy", + "annotation": null }, { "space_type_name": "multifamily", @@ -309,7 +329,8 @@ "ventilation_space_type_name": "multifamily_ventilation", "electric_equipment_space_type_name": null, "natural_gas_equipment_space_type_name": null, - "schedule_set_name": null + "schedule_set_name": null, + "annotation": "common areas in a multifamily building, NOT dwelling units" }, { "space_type_name": "nursery", @@ -317,7 +338,8 @@ "ventilation_space_type_name": "nursery_ventilation", "electric_equipment_space_type_name": "patient_room_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "patient_room" + "schedule_set_name": "patient_room", + "annotation": null }, { "space_type_name": "nurses station", @@ -325,7 +347,8 @@ "ventilation_space_type_name": "nurses_station_ventilation", "electric_equipment_space_type_name": "nurses_station_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "nurses_station" + "schedule_set_name": "nurses_station", + "annotation": null }, { "space_type_name": "office", @@ -333,7 +356,8 @@ "ventilation_space_type_name": "office_ventilation", "electric_equipment_space_type_name": "office_open_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "office_open" + "schedule_set_name": "office_open", + "annotation": null }, { "space_type_name": "office, enclosed", @@ -341,7 +365,8 @@ "ventilation_space_type_name": "office_enclosed_ventilation", "electric_equipment_space_type_name": "office_enclosed_lte_250_sf_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "office_enclosed_lte_250_sf" + "schedule_set_name": "office_enclosed_lte_250_sf", + "annotation": null }, { "space_type_name": "operating room", @@ -349,7 +374,8 @@ "ventilation_space_type_name": "operating_room_ventilation", "electric_equipment_space_type_name": "operating_room_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "operating_room" + "schedule_set_name": "operating_room", + "annotation": null }, { "space_type_name": "patient room", @@ -357,7 +383,8 @@ "ventilation_space_type_name": "patient_room_ventilation", "electric_equipment_space_type_name": "patient_room_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "patient_room" + "schedule_set_name": "patient_room", + "annotation": null }, { "space_type_name": "pharmacy", @@ -365,7 +392,8 @@ "ventilation_space_type_name": "pharmacy_ventilation", "electric_equipment_space_type_name": "pharmacy_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "pharmacy" + "schedule_set_name": "pharmacy", + "annotation": null }, { "space_type_name": "physical therapy", @@ -373,7 +401,8 @@ "ventilation_space_type_name": "physical_therapy_ventilation", "electric_equipment_space_type_name": "physical_therapy_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "physical_therapy" + "schedule_set_name": "physical_therapy", + "annotation": null }, { "space_type_name": "playing area", @@ -381,7 +410,8 @@ "ventilation_space_type_name": "playing_area_ventilation", "electric_equipment_space_type_name": "gymnasium_playing_area_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "gymnasium_playing_area" + "schedule_set_name": "gymnasium_playing_area", + "annotation": null }, { "space_type_name": "plenum", @@ -389,7 +419,8 @@ "ventilation_space_type_name": "plenum_ventilation", "electric_equipment_space_type_name": "plenum_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "plenum" + "schedule_set_name": "plenum", + "annotation": null }, { "space_type_name": "post office", @@ -397,7 +428,8 @@ "ventilation_space_type_name": "post_office_ventilation", "electric_equipment_space_type_name": "post_office_sorting_area_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "post_office_sorting_area" + "schedule_set_name": "post_office_sorting_area", + "annotation": null }, { "space_type_name": "recovery", @@ -405,15 +437,17 @@ "ventilation_space_type_name": "recovery_ventilation", "electric_equipment_space_type_name": "patient_room_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "patient_room" + "schedule_set_name": "patient_room", + "annotation": null }, { - "space_type_name": "recreation/common living", + "space_type_name": "recreation, common living", "lighting_space_type_name": "recreation_common_living_lighting", "ventilation_space_type_name": "recreation_common_living_ventilation", "electric_equipment_space_type_name": "lounge_breakroom_all_other_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "lounge_breakroom_all_other" + "schedule_set_name": "lounge_breakroom_all_other", + "annotation": null }, { "space_type_name": "restroom", @@ -421,7 +455,8 @@ "ventilation_space_type_name": "restroom_ventilation", "electric_equipment_space_type_name": "restroom_all_other_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "restroom_all_other" + "schedule_set_name": "restroom_all_other", + "annotation": null }, { "space_type_name": "retail", @@ -429,7 +464,8 @@ "ventilation_space_type_name": "retail_sales_ventilation", "electric_equipment_space_type_name": "sales_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "sales" + "schedule_set_name": "sales", + "annotation": null }, { "space_type_name": "shaft", @@ -437,7 +473,8 @@ "ventilation_space_type_name": "shaft_ventilation", "electric_equipment_space_type_name": "shaft_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "shaft" + "schedule_set_name": "shaft", + "annotation": null }, { "space_type_name": "sleeping quarters", @@ -445,7 +482,8 @@ "ventilation_space_type_name": "sleeping_quarters_ventilation", "electric_equipment_space_type_name": "firestation_sleeping_quarters_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "firestation_sleeping_quarters" + "schedule_set_name": "firestation_sleeping_quarters", + "annotation": "sleeping quarters such as in a dormitory" }, { "space_type_name": "sports arena", @@ -453,7 +491,8 @@ "ventilation_space_type_name": "sports_arena_ventilation", "electric_equipment_space_type_name": "sports_arena_playing_area_class_ii_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "sports_arena_playing_area_class_ii" + "schedule_set_name": "sports_arena_playing_area_class_ii", + "annotation": null }, { "space_type_name": "stairwell", @@ -461,7 +500,8 @@ "ventilation_space_type_name": "stairwell_ventilation", "electric_equipment_space_type_name": "stairwell_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "stairwell" + "schedule_set_name": "stairwell", + "annotation": null }, { "space_type_name": "storage", @@ -469,7 +509,8 @@ "ventilation_space_type_name": "storage_ventilation", "electric_equipment_space_type_name": "storage_50_to_1000_sf_all_other_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "storage_50_to_1000_sf_all_other" + "schedule_set_name": "storage_50_to_1000_sf_all_other", + "annotation": null }, { "space_type_name": "transportation", @@ -477,7 +518,8 @@ "ventilation_space_type_name": "transportation_ventilation", "electric_equipment_space_type_name": "transportation_ticket_counter_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "transportation_ticket_counter" + "schedule_set_name": "transportation_ticket_counter", + "annotation": null }, { "space_type_name": "vehicular maintenance", @@ -485,7 +527,8 @@ "ventilation_space_type_name": "vehicular_maintenance_ventilation", "electric_equipment_space_type_name": "vehicular_maintenance_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "vehicular_maintenance" + "schedule_set_name": "vehicular_maintenance", + "annotation": null }, { "space_type_name": "workshop", @@ -493,7 +536,8 @@ "ventilation_space_type_name": "workshop_ventilation", "electric_equipment_space_type_name": "workshop_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "workshop" + "schedule_set_name": "workshop", + "annotation": null }, { "space_type_name": "worship", @@ -501,6 +545,7 @@ "ventilation_space_type_name": "worship_ventilation", "electric_equipment_space_type_name": "worship_pulpit_choir_area_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": "worship_pulpit_choir_area" + "schedule_set_name": "worship_pulpit_choir_area", + "annotation": null } ] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/level_2_electric_equipment.csv b/data/openstudio_standards_data/database_files/level_2_electric_equipment.csv index cf99d4dcea..5d396f28d3 100644 --- a/data/openstudio_standards_data/database_files/level_2_electric_equipment.csv +++ b/data/openstudio_standards_data/database_files/level_2_electric_equipment.csv @@ -1,94 +1,96 @@ -electric_equipment_space_type_name,electric_equipment_minimum_epd,electric_equipment_average_epd,electric_equipment_median_epd,electric_equipment_maximum_epd,electric_equipment_epd_unit -corridor_all_other_electric_equipment,0,0.28,0.24,0.82,W/ft2 -dining_all_other_electric_equipment,0.32,0.55,0.55,0.82,W/ft2 -electrical_mechanical_electric_equipment,0,0,0,0,W/ft2 -kitchen_electric_equipment,0.3,0.76,0.71,2.52,W/ft2 -laboratory_electric_equipment,0.49,0.78,0.7,2.02,W/ft2 -lobby_all_other_electric_equipment,0.16,0.41,0.35,0.83,W/ft2 -locker_room_electric_equipment,0,0.38,0.44,0.97,W/ft2 -lounge_breakroom_all_other_electric_equipment,0,0.49,0.52,0.88,W/ft2 -office_enclosed_lte_250_sf_electric_equipment,0.51,0.68,0.68,0.89,W/ft2 -office_enclosed_gt_250_sf_electric_equipment,0.65,0.7,0.69,0.82,W/ft2 -office_open_electric_equipment,0.53,0.66,0.67,0.81,W/ft2 -restroom_all_other_electric_equipment,0,0,0,0,W/ft2 -stairwell_electric_equipment,0,0.25,0.25,0.53,W/ft2 -storage_lt_50_sf_all_other_electric_equipment,0,0,0,0,W/ft2 -storage_50_to_1000_sf_all_other_electric_equipment,0,0,0,0,W/ft2 -vehicular_maintenance_electric_equipment,0.65,0.69,0.69,0.73,W/ft2 -workshop_electric_equipment,0,0.54,0.57,0.74,W/ft2 -atrium_first_three_floors_electric_equipment,0,0.52,0.54,0.75,W/ft2 -audience_seating_convention_center_electric_equipment,0.63,0.63,0.63,0.63,W/ft2 -classroom_lecture_training_all_other_electric_equipment,0.5,0.63,0.62,0.8,W/ft2 -conference_meeting_multipurpose_electric_equipment,0.42,0.62,0.62,0.97,W/ft2 -exhibit_convention_center_electric_equipment,0.84,0.84,0.84,0.84,W/ft2 -gymnasium_exercise_area_electric_equipment,0.27,0.48,0.49,0.68,W/ft2 -gymnasium_playing_area_electric_equipment,0,0.51,0.51,1.06,W/ft2 -laundry_washing_electric_equipment,0,0.39,0.39,0.59,W/ft2 -lobby_elevator_electric_equipment,0.32,0.32,0.32,0.32,W/ft2 -nurses_station_electric_equipment,0,0.52,0.57,0.85,W/ft2 -post_office_sorting_area_electric_equipment,0,0.23,0.24,0.39,W/ft2 -sales_electric_equipment,0.41,0.67,0.67,0.92,W/ft2 -sports_arena_playing_area_class_iv_electric_equipment,0.32,0.5,0.64,0.69,W/ft2 -audience_seating_all_other_electric_equipment,0.31,0.49,0.46,0.75,W/ft2 -confinement_cells_electric_equipment,0.22,0.26,0.26,0.32,W/ft2 -courtroom_electric_equipment,0.25,0.4,0.4,0.56,W/ft2 -judges_chambers_electric_equipment,0.5,0.59,0.59,0.68,W/ft2 -library_stacks_electric_equipment,0,0.2,0.2,0.33,W/ft2 -storage_inactive_electric_equipment,0,0,0,0,W/ft2 -dining_bar_lounge_leisure_electric_equipment,0.5,0.5,0.5,0.5,W/ft2 -dining_cafeteria_fast_food_electric_equipment,0.6,0.6,0.6,0.6,W/ft2 -dining_family_electric_equipment,0.78,0.78,0.78,0.78,W/ft2 -computer_room_electric_equipment,0.69,0.7,0.69,0.73,W/ft2 -dormitory_living_quarters_electric_equipment,0.23,0.44,0.42,0.62,W/ft2 -audience_seating_exercise_center_electric_equipment,0.6,0.6,0.6,0.6,W/ft2 -exam_treatment_electric_equipment,0.51,0.56,0.53,0.66,W/ft2 -library_reading_electric_equipment,0.32,0.49,0.46,0.71,W/ft2 -emergency_vehicle_garage_electric_equipment,0.39,0.39,0.39,0.39,W/ft2 -firestation_sleeping_quarters_electric_equipment,0.37,0.37,0.37,0.37,W/ft2 -parking_area_interior_electric_equipment,0.11,0.27,0.3,0.32,W/ft2 -audience_seating_gymnasium_electric_equipment,0.64,0.64,0.64,0.64,W/ft2 -emergency_room_electric_equipment,0.61,0.62,0.62,0.62,W/ft2 -patient_room_electric_equipment,0.71,0.72,0.72,0.73,W/ft2 -pharmacy_electric_equipment,0.47,0.64,0.72,0.74,W/ft2 -corridor_hospital_electric_equipment,0.3,0.3,0.3,0.3,W/ft2 -fellowship_hall_religious_facility_electric_equipment,0.36,0.39,0.39,0.41,W/ft2 -lounge_breakroom_healthcare_facility_electric_equipment,0.75,0.75,0.75,0.75,W/ft2 -operating_room_electric_equipment,0.77,0.77,0.77,0.77,W/ft2 -physical_therapy_electric_equipment,0.73,0.73,0.73,0.73,W/ft2 -storage_lt_50_sf_hospital_electric_equipment,0,0,0,0,W/ft2 -storage_50_to_1000_sf_hospital_electric_equipment,0,0,0,0,W/ft2 -guest_room_electric_equipment,0.47,0.53,0.53,0.58,W/ft2 -lobby_hotel_electric_equipment,0.5,0.5,0.5,0.5,W/ft2 -library_cataloging_electric_equipment,0.21,0.21,0.21,0.21,W/ft2 -museum_exhibit_area_electric_equipment,0.32,0.46,0.43,0.68,W/ft2 -corridor_manufacturing_facility_electric_equipment,0.38,0.38,0.38,0.38,W/ft2 -manufacturing_equipment_room_electric_equipment,0,0,0,0,W/ft2 -manufacturing_low_bay_electric_equipment,0.67,0.67,0.67,0.67,W/ft2 -performing_arts_dressing_room_electric_equipment,0.29,0.41,0.43,0.5,W/ft2 -audience_seating_auditorium_electric_equipment,0.26,0.29,0.29,0.32,W/ft2 -audience_seating_motion_picture_theater_electric_equipment,0.28,0.28,0.28,0.28,W/ft2 -lobby_motion_picture_theater_electric_equipment,0.33,0.33,0.33,0.33,W/ft2 -dwelling_unit_electric_equipment,0.25,0.25,0.25,0.25,W/ft2 -museum_restoration_electric_equipment,0.21,0.21,0.21,0.21,W/ft2 -banking_activity_electric_equipment,0.54,0.55,0.55,0.56,W/ft2 -warehouse_fine_storage_electric_equipment,0,0.06,0.06,0.12,W/ft2 -classroom_lecture_training_penitentiary_electric_equipment,0.41,0.41,0.41,0.41,W/ft2 -dining_penitentiary_electric_equipment,0.35,0.35,0.35,0.35,W/ft2 -audience_seating_performing_arts_theater_electric_equipment,0.27,0.27,0.27,0.27,W/ft2 -lobby_performing_arts_theater_electric_equipment,0.33,0.33,0.33,0.33,W/ft2 -audience_seating_religious_facility_electric_equipment,0.41,0.41,0.41,0.41,W/ft2 -worship_pulpit_choir_area_electric_equipment,0.42,0.42,0.42,0.42,W/ft2 -classroom_lecture_training_preschool_to_12th_electric_equipment,0.67,0.67,0.67,0.67,W/ft2 -sports_arena_playing_area_class_ii_electric_equipment,0.32,0.48,0.48,0.64,W/ft2 -audience_seating_sports_arena_electric_equipment,0.38,0.38,0.38,0.38,W/ft2 -airport_concourse_electric_equipment,0.52,0.52,0.52,0.52,W/ft2 -atrium_lt_20_ft_height_electric_equipment,0.53,0.53,0.53,0.53,W/ft2 -atrium_gt_40_ft_height_electric_equipment,0.53,0.53,0.53,0.53,W/ft2 -atrium_gte_20_ft_and_lte_40_ft_in_height_electric_equipment,0.53,0.53,0.53,0.53,W/ft2 -baggage_carousel_electric_equipment,0.55,0.55,0.55,0.55,W/ft2 -seating_area_general_electric_equipment,0.25,0.25,0.25,0.25,W/ft2 -transportation_ticket_counter_electric_equipment,0.74,0.74,0.74,0.74,W/ft2 -warehouse_bulk_storage_electric_equipment,0.11,0.11,0.11,0.11,W/ft2 -attic_electric_equipment,0,0,0,0,W/ft2 -plenum_electric_equipment,0,0,0,0,W/ft2 -shaft_electric_equipment,0,0,0,0,W/ft2 +electric_equipment_space_type_name,electric_equipment_minimum_epd,electric_equipment_average_epd,electric_equipment_median_epd,electric_equipment_maximum_epd,electric_equipment_epd_unit,electric_equipment_fraction_latent,electric_equipment_fraction_radiant,electric_equipment_fraction_lost +corridor_all_other_electric_equipment,0,0.28,0.24,0.82,W/ft2,0,0,0 +dining_all_other_electric_equipment,0.32,0.55,0.55,0.82,W/ft2,0,0,0 +electrical_mechanical_electric_equipment,0,0,0,0,W/ft2,0,0,0 +kitchen_electric_equipment,0.3,0.76,0.71,2.52,W/ft2,0.25,0.5,0.1 +laboratory_electric_equipment,0.49,0.78,0.7,2.02,W/ft2,0,0,0 +lobby_all_other_electric_equipment,0.16,0.41,0.35,0.83,W/ft2,0,0,0 +locker_room_electric_equipment,0,0.38,0.44,0.97,W/ft2,0,0,0 +lounge_breakroom_all_other_electric_equipment,0,0.49,0.52,0.88,W/ft2,0,0,0 +office_enclosed_lte_250_sf_electric_equipment,0.51,0.68,0.68,0.89,W/ft2,0,0,0 +office_enclosed_gt_250_sf_electric_equipment,0.65,0.7,0.69,0.82,W/ft2,0,0,0 +office_open_electric_equipment,0.53,0.66,0.67,0.81,W/ft2,0,0,0 +restroom_all_other_electric_equipment,0,0,0,0,W/ft2,0,0,0 +stairwell_electric_equipment,0,0.25,0.25,0.53,W/ft2,0,0,0 +storage_lt_50_sf_all_other_electric_equipment,0,0,0,0,W/ft2,0,0,0 +storage_50_to_1000_sf_all_other_electric_equipment,0,0,0,0,W/ft2,0,0,0 +vehicular_maintenance_electric_equipment,0.65,0.69,0.69,0.73,W/ft2,0,0,0 +workshop_electric_equipment,0,0.54,0.57,0.74,W/ft2,0,0,0 +atrium_first_three_floors_electric_equipment,0,0.52,0.54,0.75,W/ft2,0,0,0 +audience_seating_convention_center_electric_equipment,0.63,0.63,0.63,0.63,W/ft2,0,0,0 +classroom_lecture_training_all_other_electric_equipment,0.5,0.63,0.62,0.8,W/ft2,0,0,0 +conference_meeting_multipurpose_electric_equipment,0.42,0.62,0.62,0.97,W/ft2,0,0,0 +exhibit_convention_center_electric_equipment,0.84,0.84,0.84,0.84,W/ft2,0,0,0 +gymnasium_exercise_area_electric_equipment,0.27,0.48,0.49,0.68,W/ft2,0,0,0 +gymnasium_playing_area_electric_equipment,0,0.51,0.51,1.06,W/ft2,0,0,0 +laundry_washing_electric_equipment,0,0.39,0.39,0.59,W/ft2,0,0,0 +lobby_elevator_electric_equipment,0.32,0.32,0.32,0.32,W/ft2,0,0,0 +nurses_station_electric_equipment,0,0.52,0.57,0.85,W/ft2,0,0,0 +post_office_sorting_area_electric_equipment,0,0.23,0.24,0.39,W/ft2,0,0,0 +sales_electric_equipment,0.41,0.67,0.67,0.92,W/ft2,0,0,0 +sports_arena_playing_area_class_iv_electric_equipment,0.32,0.5,0.64,0.69,W/ft2,0,0,0 +audience_seating_all_other_electric_equipment,0.31,0.49,0.46,0.75,W/ft2,0,0,0 +confinement_cells_electric_equipment,0.22,0.26,0.26,0.32,W/ft2,0,0,0 +courtroom_electric_equipment,0.25,0.4,0.4,0.56,W/ft2,0,0,0 +judges_chambers_electric_equipment,0.5,0.59,0.59,0.68,W/ft2,0,0,0 +library_stacks_electric_equipment,0,0.2,0.2,0.33,W/ft2,0,0,0 +storage_inactive_electric_equipment,0,0,0,0,W/ft2,0,0,0 +dining_bar_lounge_leisure_electric_equipment,0.5,0.5,0.5,0.5,W/ft2,0.2,0.3,0 +dining_cafeteria_fast_food_electric_equipment,0.6,0.6,0.6,0.6,W/ft2,0.2,0.3,0 +dining_family_electric_equipment,0.78,0.78,0.78,0.78,W/ft2,0.2,0.3,0 +computer_room_electric_equipment,0.69,0.7,0.69,0.73,W/ft2,0,0,0 +dormitory_living_quarters_electric_equipment,0.23,0.44,0.42,0.62,W/ft2,0,0,0 +audience_seating_exercise_center_electric_equipment,0.6,0.6,0.6,0.6,W/ft2,0,0,0 +exam_treatment_electric_equipment,0.51,0.56,0.53,0.66,W/ft2,0,0,0 +library_reading_electric_equipment,0.32,0.49,0.46,0.71,W/ft2,0,0,0 +emergency_vehicle_garage_electric_equipment,0.39,0.39,0.39,0.39,W/ft2,0,0,0 +firestation_sleeping_quarters_electric_equipment,0.37,0.37,0.37,0.37,W/ft2,0,0,0 +parking_area_interior_electric_equipment,0.11,0.27,0.3,0.32,W/ft2,0,0,0 +audience_seating_gymnasium_electric_equipment,0.64,0.64,0.64,0.64,W/ft2,0,0,0 +emergency_room_electric_equipment,0.61,0.62,0.62,0.62,W/ft2,0,0,0 +patient_room_electric_equipment,0.71,0.72,0.72,0.73,W/ft2,0,0,0 +pharmacy_electric_equipment,0.47,0.64,0.72,0.74,W/ft2,0,0,0 +corridor_hospital_electric_equipment,0.3,0.3,0.3,0.3,W/ft2,0,0,0 +fellowship_hall_religious_facility_electric_equipment,0.36,0.39,0.39,0.41,W/ft2,0,0,0 +lounge_breakroom_healthcare_facility_electric_equipment,0.75,0.75,0.75,0.75,W/ft2,0,0,0 +operating_room_electric_equipment,0.77,0.77,0.77,0.77,W/ft2,0,0,0 +physical_therapy_electric_equipment,0.73,0.73,0.73,0.73,W/ft2,0,0,0 +storage_lt_50_sf_hospital_electric_equipment,0,0,0,0,W/ft2,0,0,0 +storage_50_to_1000_sf_hospital_electric_equipment,0,0,0,0,W/ft2,0,0,0 +guest_room_electric_equipment,0.47,0.53,0.53,0.58,W/ft2,0,0,0 +lobby_hotel_electric_equipment,0.5,0.5,0.5,0.5,W/ft2,0,0,0 +library_cataloging_electric_equipment,0.21,0.21,0.21,0.21,W/ft2,0,0,0 +museum_exhibit_area_electric_equipment,0.32,0.46,0.43,0.68,W/ft2,0,0,0 +corridor_manufacturing_facility_electric_equipment,0.38,0.38,0.38,0.38,W/ft2,0,0,0 +manufacturing_equipment_room_electric_equipment,0,0,0,0,W/ft2,0,0,0 +manufacturing_low_bay_electric_equipment,0.67,0.67,0.67,0.67,W/ft2,0,0,0 +performing_arts_dressing_room_electric_equipment,0.29,0.41,0.43,0.5,W/ft2,0,0,0 +audience_seating_auditorium_electric_equipment,0.26,0.29,0.29,0.32,W/ft2,0,0,0 +audience_seating_motion_picture_theater_electric_equipment,0.28,0.28,0.28,0.28,W/ft2,0,0,0 +lobby_motion_picture_theater_electric_equipment,0.33,0.33,0.33,0.33,W/ft2,0,0,0 +dwelling_unit_electric_equipment,0.25,0.25,0.25,0.25,W/ft2,0,0,0 +museum_restoration_electric_equipment,0.21,0.21,0.21,0.21,W/ft2,0,0,0 +banking_activity_electric_equipment,0.54,0.55,0.55,0.56,W/ft2,0,0,0 +warehouse_fine_storage_electric_equipment,0,0.06,0.06,0.12,W/ft2,0,0,0 +classroom_lecture_training_penitentiary_electric_equipment,0.41,0.41,0.41,0.41,W/ft2,0,0,0 +dining_penitentiary_electric_equipment,0.35,0.35,0.35,0.35,W/ft2,0.2,0.3,0 +audience_seating_performing_arts_theater_electric_equipment,0.27,0.27,0.27,0.27,W/ft2,0,0,0 +lobby_performing_arts_theater_electric_equipment,0.33,0.33,0.33,0.33,W/ft2,0,0,0 +audience_seating_religious_facility_electric_equipment,0.41,0.41,0.41,0.41,W/ft2,0,0,0 +worship_pulpit_choir_area_electric_equipment,0.42,0.42,0.42,0.42,W/ft2,0,0,0 +classroom_lecture_training_preschool_to_12th_electric_equipment,0.67,0.67,0.67,0.67,W/ft2,0,0,0 +sports_arena_playing_area_class_ii_electric_equipment,0.32,0.48,0.48,0.64,W/ft2,0,0,0 +audience_seating_sports_arena_electric_equipment,0.38,0.38,0.38,0.38,W/ft2,0,0,0 +airport_concourse_electric_equipment,0.52,0.52,0.52,0.52,W/ft2,0,0,0 +atrium_lt_20_ft_height_electric_equipment,0.53,0.53,0.53,0.53,W/ft2,0,0,0 +atrium_gt_40_ft_height_electric_equipment,0.53,0.53,0.53,0.53,W/ft2,0,0,0 +atrium_gte_20_ft_and_lte_40_ft_in_height_electric_equipment,0.53,0.53,0.53,0.53,W/ft2,0,0,0 +baggage_carousel_electric_equipment,0.55,0.55,0.55,0.55,W/ft2,0,0,0 +seating_area_general_electric_equipment,0.25,0.25,0.25,0.25,W/ft2,0,0,0 +transportation_ticket_counter_electric_equipment,0.74,0.74,0.74,0.74,W/ft2,0,0,0 +warehouse_bulk_storage_electric_equipment,0.11,0.11,0.11,0.11,W/ft2,0,0,0 +attic_electric_equipment,0,0,0,0,W/ft2,0,0,0 +plenum_electric_equipment,0,0,0,0,W/ft2,0,0,0 +shaft_electric_equipment,0,0,0,0,W/ft2,0,0,0 +datacenter_high_ite_equipment,100,300,300,500,W/ft2,0,0.1,0 +datacenter_low_ite_equipment,40,70,70,100,W/ft2,0,0.1,0 diff --git a/data/openstudio_standards_data/database_files/level_2_electric_equipment.json b/data/openstudio_standards_data/database_files/level_2_electric_equipment.json index 04fff2fb37..252e65fb48 100644 --- a/data/openstudio_standards_data/database_files/level_2_electric_equipment.json +++ b/data/openstudio_standards_data/database_files/level_2_electric_equipment.json @@ -5,7 +5,10 @@ "electric_equipment_average_epd": 0.28, "electric_equipment_median_epd": 0.24, "electric_equipment_maximum_epd": 0.82, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "dining_all_other_electric_equipment", @@ -13,7 +16,10 @@ "electric_equipment_average_epd": 0.55, "electric_equipment_median_epd": 0.55, "electric_equipment_maximum_epd": 0.82, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "electrical_mechanical_electric_equipment", @@ -21,7 +27,10 @@ "electric_equipment_average_epd": 0, "electric_equipment_median_epd": 0, "electric_equipment_maximum_epd": 0, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "kitchen_electric_equipment", @@ -29,7 +38,10 @@ "electric_equipment_average_epd": 0.76, "electric_equipment_median_epd": 0.71, "electric_equipment_maximum_epd": 2.52, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0.25, + "electric_equipment_fraction_radiant": 0.5, + "electric_equipment_fraction_lost": 0.1 }, { "electric_equipment_space_type_name": "laboratory_electric_equipment", @@ -37,7 +49,10 @@ "electric_equipment_average_epd": 0.78, "electric_equipment_median_epd": 0.7, "electric_equipment_maximum_epd": 2.02, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "lobby_all_other_electric_equipment", @@ -45,7 +60,10 @@ "electric_equipment_average_epd": 0.41, "electric_equipment_median_epd": 0.35, "electric_equipment_maximum_epd": 0.83, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "locker_room_electric_equipment", @@ -53,7 +71,10 @@ "electric_equipment_average_epd": 0.38, "electric_equipment_median_epd": 0.44, "electric_equipment_maximum_epd": 0.97, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "lounge_breakroom_all_other_electric_equipment", @@ -61,7 +82,10 @@ "electric_equipment_average_epd": 0.49, "electric_equipment_median_epd": 0.52, "electric_equipment_maximum_epd": 0.88, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "office_enclosed_lte_250_sf_electric_equipment", @@ -69,7 +93,10 @@ "electric_equipment_average_epd": 0.68, "electric_equipment_median_epd": 0.68, "electric_equipment_maximum_epd": 0.89, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "office_enclosed_gt_250_sf_electric_equipment", @@ -77,7 +104,10 @@ "electric_equipment_average_epd": 0.7, "electric_equipment_median_epd": 0.69, "electric_equipment_maximum_epd": 0.82, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "office_open_electric_equipment", @@ -85,7 +115,10 @@ "electric_equipment_average_epd": 0.66, "electric_equipment_median_epd": 0.67, "electric_equipment_maximum_epd": 0.81, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "restroom_all_other_electric_equipment", @@ -93,7 +126,10 @@ "electric_equipment_average_epd": 0, "electric_equipment_median_epd": 0, "electric_equipment_maximum_epd": 0, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "stairwell_electric_equipment", @@ -101,7 +137,10 @@ "electric_equipment_average_epd": 0.25, "electric_equipment_median_epd": 0.25, "electric_equipment_maximum_epd": 0.53, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "storage_lt_50_sf_all_other_electric_equipment", @@ -109,7 +148,10 @@ "electric_equipment_average_epd": 0, "electric_equipment_median_epd": 0, "electric_equipment_maximum_epd": 0, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "storage_50_to_1000_sf_all_other_electric_equipment", @@ -117,7 +159,10 @@ "electric_equipment_average_epd": 0, "electric_equipment_median_epd": 0, "electric_equipment_maximum_epd": 0, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "vehicular_maintenance_electric_equipment", @@ -125,7 +170,10 @@ "electric_equipment_average_epd": 0.69, "electric_equipment_median_epd": 0.69, "electric_equipment_maximum_epd": 0.73, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "workshop_electric_equipment", @@ -133,7 +181,10 @@ "electric_equipment_average_epd": 0.54, "electric_equipment_median_epd": 0.57, "electric_equipment_maximum_epd": 0.74, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "atrium_first_three_floors_electric_equipment", @@ -141,7 +192,10 @@ "electric_equipment_average_epd": 0.52, "electric_equipment_median_epd": 0.54, "electric_equipment_maximum_epd": 0.75, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "audience_seating_convention_center_electric_equipment", @@ -149,7 +203,10 @@ "electric_equipment_average_epd": 0.63, "electric_equipment_median_epd": 0.63, "electric_equipment_maximum_epd": 0.63, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "classroom_lecture_training_all_other_electric_equipment", @@ -157,7 +214,10 @@ "electric_equipment_average_epd": 0.63, "electric_equipment_median_epd": 0.62, "electric_equipment_maximum_epd": 0.8, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "conference_meeting_multipurpose_electric_equipment", @@ -165,7 +225,10 @@ "electric_equipment_average_epd": 0.62, "electric_equipment_median_epd": 0.62, "electric_equipment_maximum_epd": 0.97, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "exhibit_convention_center_electric_equipment", @@ -173,7 +236,10 @@ "electric_equipment_average_epd": 0.84, "electric_equipment_median_epd": 0.84, "electric_equipment_maximum_epd": 0.84, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "gymnasium_exercise_area_electric_equipment", @@ -181,7 +247,10 @@ "electric_equipment_average_epd": 0.48, "electric_equipment_median_epd": 0.49, "electric_equipment_maximum_epd": 0.68, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "gymnasium_playing_area_electric_equipment", @@ -189,7 +258,10 @@ "electric_equipment_average_epd": 0.51, "electric_equipment_median_epd": 0.51, "electric_equipment_maximum_epd": 1.06, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "laundry_washing_electric_equipment", @@ -197,7 +269,10 @@ "electric_equipment_average_epd": 0.39, "electric_equipment_median_epd": 0.39, "electric_equipment_maximum_epd": 0.59, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "lobby_elevator_electric_equipment", @@ -205,7 +280,10 @@ "electric_equipment_average_epd": 0.32, "electric_equipment_median_epd": 0.32, "electric_equipment_maximum_epd": 0.32, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "nurses_station_electric_equipment", @@ -213,7 +291,10 @@ "electric_equipment_average_epd": 0.52, "electric_equipment_median_epd": 0.57, "electric_equipment_maximum_epd": 0.85, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "post_office_sorting_area_electric_equipment", @@ -221,7 +302,10 @@ "electric_equipment_average_epd": 0.23, "electric_equipment_median_epd": 0.24, "electric_equipment_maximum_epd": 0.39, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "sales_electric_equipment", @@ -229,7 +313,10 @@ "electric_equipment_average_epd": 0.67, "electric_equipment_median_epd": 0.67, "electric_equipment_maximum_epd": 0.92, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "sports_arena_playing_area_class_iv_electric_equipment", @@ -237,7 +324,10 @@ "electric_equipment_average_epd": 0.5, "electric_equipment_median_epd": 0.64, "electric_equipment_maximum_epd": 0.69, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "audience_seating_all_other_electric_equipment", @@ -245,7 +335,10 @@ "electric_equipment_average_epd": 0.49, "electric_equipment_median_epd": 0.46, "electric_equipment_maximum_epd": 0.75, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "confinement_cells_electric_equipment", @@ -253,7 +346,10 @@ "electric_equipment_average_epd": 0.26, "electric_equipment_median_epd": 0.26, "electric_equipment_maximum_epd": 0.32, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "courtroom_electric_equipment", @@ -261,7 +357,10 @@ "electric_equipment_average_epd": 0.4, "electric_equipment_median_epd": 0.4, "electric_equipment_maximum_epd": 0.56, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "judges_chambers_electric_equipment", @@ -269,7 +368,10 @@ "electric_equipment_average_epd": 0.59, "electric_equipment_median_epd": 0.59, "electric_equipment_maximum_epd": 0.68, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "library_stacks_electric_equipment", @@ -277,7 +379,10 @@ "electric_equipment_average_epd": 0.2, "electric_equipment_median_epd": 0.2, "electric_equipment_maximum_epd": 0.33, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "storage_inactive_electric_equipment", @@ -285,7 +390,10 @@ "electric_equipment_average_epd": 0, "electric_equipment_median_epd": 0, "electric_equipment_maximum_epd": 0, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "dining_bar_lounge_leisure_electric_equipment", @@ -293,7 +401,10 @@ "electric_equipment_average_epd": 0.5, "electric_equipment_median_epd": 0.5, "electric_equipment_maximum_epd": 0.5, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0.2, + "electric_equipment_fraction_radiant": 0.3, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "dining_cafeteria_fast_food_electric_equipment", @@ -301,7 +412,10 @@ "electric_equipment_average_epd": 0.6, "electric_equipment_median_epd": 0.6, "electric_equipment_maximum_epd": 0.6, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0.2, + "electric_equipment_fraction_radiant": 0.3, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "dining_family_electric_equipment", @@ -309,7 +423,10 @@ "electric_equipment_average_epd": 0.78, "electric_equipment_median_epd": 0.78, "electric_equipment_maximum_epd": 0.78, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0.2, + "electric_equipment_fraction_radiant": 0.3, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "computer_room_electric_equipment", @@ -317,7 +434,10 @@ "electric_equipment_average_epd": 0.7, "electric_equipment_median_epd": 0.69, "electric_equipment_maximum_epd": 0.73, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "dormitory_living_quarters_electric_equipment", @@ -325,7 +445,10 @@ "electric_equipment_average_epd": 0.44, "electric_equipment_median_epd": 0.42, "electric_equipment_maximum_epd": 0.62, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "audience_seating_exercise_center_electric_equipment", @@ -333,7 +456,10 @@ "electric_equipment_average_epd": 0.6, "electric_equipment_median_epd": 0.6, "electric_equipment_maximum_epd": 0.6, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "exam_treatment_electric_equipment", @@ -341,7 +467,10 @@ "electric_equipment_average_epd": 0.56, "electric_equipment_median_epd": 0.53, "electric_equipment_maximum_epd": 0.66, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "library_reading_electric_equipment", @@ -349,7 +478,10 @@ "electric_equipment_average_epd": 0.49, "electric_equipment_median_epd": 0.46, "electric_equipment_maximum_epd": 0.71, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "emergency_vehicle_garage_electric_equipment", @@ -357,7 +489,10 @@ "electric_equipment_average_epd": 0.39, "electric_equipment_median_epd": 0.39, "electric_equipment_maximum_epd": 0.39, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "firestation_sleeping_quarters_electric_equipment", @@ -365,7 +500,10 @@ "electric_equipment_average_epd": 0.37, "electric_equipment_median_epd": 0.37, "electric_equipment_maximum_epd": 0.37, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "parking_area_interior_electric_equipment", @@ -373,7 +511,10 @@ "electric_equipment_average_epd": 0.27, "electric_equipment_median_epd": 0.3, "electric_equipment_maximum_epd": 0.32, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "audience_seating_gymnasium_electric_equipment", @@ -381,7 +522,10 @@ "electric_equipment_average_epd": 0.64, "electric_equipment_median_epd": 0.64, "electric_equipment_maximum_epd": 0.64, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "emergency_room_electric_equipment", @@ -389,7 +533,10 @@ "electric_equipment_average_epd": 0.62, "electric_equipment_median_epd": 0.62, "electric_equipment_maximum_epd": 0.62, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "patient_room_electric_equipment", @@ -397,7 +544,10 @@ "electric_equipment_average_epd": 0.72, "electric_equipment_median_epd": 0.72, "electric_equipment_maximum_epd": 0.73, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "pharmacy_electric_equipment", @@ -405,7 +555,10 @@ "electric_equipment_average_epd": 0.64, "electric_equipment_median_epd": 0.72, "electric_equipment_maximum_epd": 0.74, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "corridor_hospital_electric_equipment", @@ -413,7 +566,10 @@ "electric_equipment_average_epd": 0.3, "electric_equipment_median_epd": 0.3, "electric_equipment_maximum_epd": 0.3, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "fellowship_hall_religious_facility_electric_equipment", @@ -421,7 +577,10 @@ "electric_equipment_average_epd": 0.39, "electric_equipment_median_epd": 0.39, "electric_equipment_maximum_epd": 0.41, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "lounge_breakroom_healthcare_facility_electric_equipment", @@ -429,7 +588,10 @@ "electric_equipment_average_epd": 0.75, "electric_equipment_median_epd": 0.75, "electric_equipment_maximum_epd": 0.75, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "operating_room_electric_equipment", @@ -437,7 +599,10 @@ "electric_equipment_average_epd": 0.77, "electric_equipment_median_epd": 0.77, "electric_equipment_maximum_epd": 0.77, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "physical_therapy_electric_equipment", @@ -445,7 +610,10 @@ "electric_equipment_average_epd": 0.73, "electric_equipment_median_epd": 0.73, "electric_equipment_maximum_epd": 0.73, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "storage_lt_50_sf_hospital_electric_equipment", @@ -453,7 +621,10 @@ "electric_equipment_average_epd": 0, "electric_equipment_median_epd": 0, "electric_equipment_maximum_epd": 0, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "storage_50_to_1000_sf_hospital_electric_equipment", @@ -461,7 +632,10 @@ "electric_equipment_average_epd": 0, "electric_equipment_median_epd": 0, "electric_equipment_maximum_epd": 0, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "guest_room_electric_equipment", @@ -469,7 +643,10 @@ "electric_equipment_average_epd": 0.53, "electric_equipment_median_epd": 0.53, "electric_equipment_maximum_epd": 0.58, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "lobby_hotel_electric_equipment", @@ -477,7 +654,10 @@ "electric_equipment_average_epd": 0.5, "electric_equipment_median_epd": 0.5, "electric_equipment_maximum_epd": 0.5, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "library_cataloging_electric_equipment", @@ -485,7 +665,10 @@ "electric_equipment_average_epd": 0.21, "electric_equipment_median_epd": 0.21, "electric_equipment_maximum_epd": 0.21, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "museum_exhibit_area_electric_equipment", @@ -493,7 +676,10 @@ "electric_equipment_average_epd": 0.46, "electric_equipment_median_epd": 0.43, "electric_equipment_maximum_epd": 0.68, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "corridor_manufacturing_facility_electric_equipment", @@ -501,7 +687,10 @@ "electric_equipment_average_epd": 0.38, "electric_equipment_median_epd": 0.38, "electric_equipment_maximum_epd": 0.38, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "manufacturing_equipment_room_electric_equipment", @@ -509,7 +698,10 @@ "electric_equipment_average_epd": 0, "electric_equipment_median_epd": 0, "electric_equipment_maximum_epd": 0, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "manufacturing_low_bay_electric_equipment", @@ -517,7 +709,10 @@ "electric_equipment_average_epd": 0.67, "electric_equipment_median_epd": 0.67, "electric_equipment_maximum_epd": 0.67, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "performing_arts_dressing_room_electric_equipment", @@ -525,7 +720,10 @@ "electric_equipment_average_epd": 0.41, "electric_equipment_median_epd": 0.43, "electric_equipment_maximum_epd": 0.5, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "audience_seating_auditorium_electric_equipment", @@ -533,7 +731,10 @@ "electric_equipment_average_epd": 0.29, "electric_equipment_median_epd": 0.29, "electric_equipment_maximum_epd": 0.32, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "audience_seating_motion_picture_theater_electric_equipment", @@ -541,7 +742,10 @@ "electric_equipment_average_epd": 0.28, "electric_equipment_median_epd": 0.28, "electric_equipment_maximum_epd": 0.28, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "lobby_motion_picture_theater_electric_equipment", @@ -549,7 +753,10 @@ "electric_equipment_average_epd": 0.33, "electric_equipment_median_epd": 0.33, "electric_equipment_maximum_epd": 0.33, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "dwelling_unit_electric_equipment", @@ -557,7 +764,10 @@ "electric_equipment_average_epd": 0.25, "electric_equipment_median_epd": 0.25, "electric_equipment_maximum_epd": 0.25, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "museum_restoration_electric_equipment", @@ -565,7 +775,10 @@ "electric_equipment_average_epd": 0.21, "electric_equipment_median_epd": 0.21, "electric_equipment_maximum_epd": 0.21, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "banking_activity_electric_equipment", @@ -573,7 +786,10 @@ "electric_equipment_average_epd": 0.55, "electric_equipment_median_epd": 0.55, "electric_equipment_maximum_epd": 0.56, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "warehouse_fine_storage_electric_equipment", @@ -581,7 +797,10 @@ "electric_equipment_average_epd": 0.06, "electric_equipment_median_epd": 0.06, "electric_equipment_maximum_epd": 0.12, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "classroom_lecture_training_penitentiary_electric_equipment", @@ -589,7 +808,10 @@ "electric_equipment_average_epd": 0.41, "electric_equipment_median_epd": 0.41, "electric_equipment_maximum_epd": 0.41, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "dining_penitentiary_electric_equipment", @@ -597,7 +819,10 @@ "electric_equipment_average_epd": 0.35, "electric_equipment_median_epd": 0.35, "electric_equipment_maximum_epd": 0.35, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0.2, + "electric_equipment_fraction_radiant": 0.3, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "audience_seating_performing_arts_theater_electric_equipment", @@ -605,7 +830,10 @@ "electric_equipment_average_epd": 0.27, "electric_equipment_median_epd": 0.27, "electric_equipment_maximum_epd": 0.27, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "lobby_performing_arts_theater_electric_equipment", @@ -613,7 +841,10 @@ "electric_equipment_average_epd": 0.33, "electric_equipment_median_epd": 0.33, "electric_equipment_maximum_epd": 0.33, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "audience_seating_religious_facility_electric_equipment", @@ -621,7 +852,10 @@ "electric_equipment_average_epd": 0.41, "electric_equipment_median_epd": 0.41, "electric_equipment_maximum_epd": 0.41, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "worship_pulpit_choir_area_electric_equipment", @@ -629,7 +863,10 @@ "electric_equipment_average_epd": 0.42, "electric_equipment_median_epd": 0.42, "electric_equipment_maximum_epd": 0.42, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "classroom_lecture_training_preschool_to_12th_electric_equipment", @@ -637,7 +874,10 @@ "electric_equipment_average_epd": 0.67, "electric_equipment_median_epd": 0.67, "electric_equipment_maximum_epd": 0.67, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "sports_arena_playing_area_class_ii_electric_equipment", @@ -645,7 +885,10 @@ "electric_equipment_average_epd": 0.48, "electric_equipment_median_epd": 0.48, "electric_equipment_maximum_epd": 0.64, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "audience_seating_sports_arena_electric_equipment", @@ -653,7 +896,10 @@ "electric_equipment_average_epd": 0.38, "electric_equipment_median_epd": 0.38, "electric_equipment_maximum_epd": 0.38, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "airport_concourse_electric_equipment", @@ -661,7 +907,10 @@ "electric_equipment_average_epd": 0.52, "electric_equipment_median_epd": 0.52, "electric_equipment_maximum_epd": 0.52, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "atrium_lt_20_ft_height_electric_equipment", @@ -669,7 +918,10 @@ "electric_equipment_average_epd": 0.53, "electric_equipment_median_epd": 0.53, "electric_equipment_maximum_epd": 0.53, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "atrium_gt_40_ft_height_electric_equipment", @@ -677,7 +929,10 @@ "electric_equipment_average_epd": 0.53, "electric_equipment_median_epd": 0.53, "electric_equipment_maximum_epd": 0.53, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "atrium_gte_20_ft_and_lte_40_ft_in_height_electric_equipment", @@ -685,7 +940,10 @@ "electric_equipment_average_epd": 0.53, "electric_equipment_median_epd": 0.53, "electric_equipment_maximum_epd": 0.53, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "baggage_carousel_electric_equipment", @@ -693,7 +951,10 @@ "electric_equipment_average_epd": 0.55, "electric_equipment_median_epd": 0.55, "electric_equipment_maximum_epd": 0.55, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "seating_area_general_electric_equipment", @@ -701,7 +962,10 @@ "electric_equipment_average_epd": 0.25, "electric_equipment_median_epd": 0.25, "electric_equipment_maximum_epd": 0.25, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "transportation_ticket_counter_electric_equipment", @@ -709,7 +973,10 @@ "electric_equipment_average_epd": 0.74, "electric_equipment_median_epd": 0.74, "electric_equipment_maximum_epd": 0.74, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "warehouse_bulk_storage_electric_equipment", @@ -717,7 +984,10 @@ "electric_equipment_average_epd": 0.11, "electric_equipment_median_epd": 0.11, "electric_equipment_maximum_epd": 0.11, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "attic_electric_equipment", @@ -725,7 +995,10 @@ "electric_equipment_average_epd": 0, "electric_equipment_median_epd": 0, "electric_equipment_maximum_epd": 0, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "plenum_electric_equipment", @@ -733,7 +1006,10 @@ "electric_equipment_average_epd": 0, "electric_equipment_median_epd": 0, "electric_equipment_maximum_epd": 0, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 }, { "electric_equipment_space_type_name": "shaft_electric_equipment", @@ -741,6 +1017,31 @@ "electric_equipment_average_epd": 0, "electric_equipment_median_epd": 0, "electric_equipment_maximum_epd": 0, - "electric_equipment_epd_unit": "W/ft2" + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 + }, + { + "electric_equipment_space_type_name": "datacenter_high_ite_equipment", + "electric_equipment_minimum_epd": 100, + "electric_equipment_average_epd": 300, + "electric_equipment_median_epd": 300, + "electric_equipment_maximum_epd": 500, + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0.1, + "electric_equipment_fraction_lost": 0 + }, + { + "electric_equipment_space_type_name": "datacenter_low_ite_equipment", + "electric_equipment_minimum_epd": 40, + "electric_equipment_average_epd": 70, + "electric_equipment_median_epd": 70, + "electric_equipment_maximum_epd": 100, + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0.1, + "electric_equipment_fraction_lost": 0 } ] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/level_2_lighting_space_types.csv b/data/openstudio_standards_data/database_files/level_2_lighting_space_types.csv index 11fac599dc..242fc785be 100644 --- a/data/openstudio_standards_data/database_files/level_2_lighting_space_types.csv +++ b/data/openstudio_standards_data/database_files/level_2_lighting_space_types.csv @@ -1,709 +1,709 @@ -lighting_space_type_name,level_3_lighting_code_definition_table,level_3_lighting_code_definition_id,lighting_technology_name,lighting_space_type_target_illuminance_setpoint -airport_concourse_lighting,level_3_lighting_90_1_2004,122,default,118 -atrium_lighting,level_3_lighting_90_1_2004,36,default,178 -none_lighting,level_3_lighting_90_1_2004,126,default,0 -audience_seating_lighting,level_3_lighting_90_1_2004,46,default,118 -baggage_carousel_lighting,level_3_lighting_90_1_2004,121,default,237 -banking_lighting,level_3_lighting_90_1_2004,77,default,355 -classroom_lecture_training_lighting,level_3_lighting_90_1_2004,48,default,471 -computer_room_lighting,level_3_lighting_90_1_2004,48,default,710 -conference_meeting_multipurpose_lighting,level_3_lighting_90_1_2004,49,default,355 -confinement_cells_lighting,level_3_lighting_90_1_2004,79,default,296 -copy_print_lighting,level_3_lighting_90_1_2004,49,default,178 -corridor_lighting,level_3_lighting_90_1_2004,52,default,178 -courtroom_lighting,level_3_lighting_90_1_2004,80,default,474 -datacenterhighite_lighting,level_3_lighting_90_1_2004,60,default,118 -datacenterlowite_lighting,level_3_lighting_90_1_2004,60,default,118 -dining_lighting,level_3_lighting_90_1_2004,58,default,308 -dressing_room_lighting,level_3_lighting_90_1_2004,59,default,237 -electrical_mechanical_lighting,level_3_lighting_90_1_2004,60,default,118 -emergency_room_lighting,level_3_lighting_90_1_2004,87,default,888 -emergency_vehicle_garage_lighting,level_3_lighting_90_1_2004,83,default,355 -exam_treatment_lighting,level_3_lighting_90_1_2004,88,default,592 -exercise_area_lighting,level_3_lighting_90_1_2004,85,default,474 -exhibit_lighting,level_3_lighting_90_1_2004,108,default,431 -guest_room_lighting,level_3_lighting_90_1_2004,99,default,178 -imaging_lighting,level_3_lighting_90_1_2004,97,default,355 -interior_parking_lighting,level_3_lighting_90_1_2004,110,default,54 -judges_chambers_lighting,level_3_lighting_90_1_2004,81,default,355 -food_preparation_lighting,level_3_lighting_90_1_2004,61,default,538 -laboratory_lighting,level_3_lighting_90_1_2004,64,default,592 -laundry_washing_lighting,level_3_lighting_90_1_2004,89,default,355 -library_lighting,level_3_lighting_90_1_2004,13,default,118 -living_quarters_lighting,level_3_lighting_90_1_2004,82,default,178 -loading_dock_lighting,level_3_lighting_90_1_2004,30,default,355 -lobby_lighting,level_3_lighting_90_1_2004,68,default,296 -locker_room_lighting,level_3_lighting_90_1_2004,59,default,237 -lounge_breakroom_lighting,level_3_lighting_90_1_2004,70,default,178 -manufacturing_lighting,level_3_lighting_90_1_2004,14,default,592 -medical_supply_lighting,level_3_lighting_90_1_2004,90,default,355 -multifamily_lighting,level_3_lighting_90_1_2004,17,default,178 -nursery_lighting,level_3_lighting_90_1_2004,92,default,355 -nurses_station_lighting,level_3_lighting_90_1_2004,91,default,355 -office_lighting,level_3_lighting_90_1_2004,19,default,414 -office_enclosed_lighting,level_3_lighting_90_1_2004,71,default,355 -operating_room_lighting,level_3_lighting_90_1_2004,93,default,1184 -patient_room_lighting,level_3_lighting_90_1_2004,94,default,355 -pharmacy_lighting,level_3_lighting_90_1_2004,95,default,888 -physical_therapy_lighting,level_3_lighting_90_1_2004,96,default,474 -playing_area_lighting,level_3_lighting_90_1_2004,86,default,592 -post_office_lighting,level_3_lighting_90_1_2004,24,default,237 -recovery_lighting,level_3_lighting_90_1_2004,98,default,592 -recreation_common_living_lighting,level_3_lighting_90_1_2004,70,default,323 -restroom_lighting,level_3_lighting_90_1_2004,73,default,178 -retail_sales_lighting,level_3_lighting_90_1_2004,117,default,474 -sleeping_quarters_lighting,level_3_lighting_90_1_2004,84,default,59 -sports_arena_lighting,level_3_lighting_90_1_2004,28,default,1184 -stairwell_lighting,level_3_lighting_90_1_2004,74,default,118 -storage_lighting,level_3_lighting_90_1_2004,34,default,118 -transportation_lighting,level_3_lighting_90_1_2004,30,default,237 -vehicular_maintenance_lighting,level_3_lighting_90_1_2004,76,default,355 -workshop_lighting,level_3_lighting_90_1_2004,32,default,592 -worship_lighting,level_3_lighting_90_1_2004,25,default,355 -ba_automotive_facility_lighting,level_3_lighting_90_1_2004,1,default,355 -ba_convention_center_lighting,level_3_lighting_90_1_2004,2,default,118 -ba_courthouse_lighting,level_3_lighting_90_1_2004,3,default,474 -ba_dining_bar_lounge_leisure_lighting,level_3_lighting_90_1_2004,4,default,118 -ba_dining_cafeteria_fast_food_lighting,level_3_lighting_90_1_2004,5,default,237 -ba_dining_family_lighting,level_3_lighting_90_1_2004,6,default,237 -ba_dormitory_lighting,level_3_lighting_90_1_2004,7,default,178 -ba_exercise_center_lighting,level_3_lighting_90_1_2004,8,default,237 -ba_fire_station_lighting,level_3_lighting_90_1_2004,23,default,118 -ba_gymnasium_lighting,level_3_lighting_90_1_2004,9,default,237 -ba_health-care_clinic_lighting,level_3_lighting_90_1_2004,10,default,592 -ba_hospital_lighting,level_3_lighting_90_1_2004,11,default,592 -ba_hotel_motel_lighting,level_3_lighting_90_1_2004,12,default,178 -ba_motion_picture_theater_lighting,level_3_lighting_90_1_2004,16,default,118 -ba_museum_lighting,level_3_lighting_90_1_2004,18,default,118 -ba_parking_garage_lighting,level_3_lighting_90_1_2004,20,default,54 -ba_penitentiary_lighting,level_3_lighting_90_1_2004,21,default,296 -ba_performing_arts_theater_lighting,level_3_lighting_90_1_2004,22,default,426 -ba_police_station_lighting,level_3_lighting_90_1_2004,23,default,118 -ba_school_university_lighting,level_3_lighting_90_1_2004,27,default,471 -ba_town_hall_lighting,level_3_lighting_90_1_2004,29,default,355 -ba_retail_lighting,level_3_lighting_90_1_2004,26,default,474 -ba_warehouse_lighting,level_3_lighting_90_1_2004,31,default,118 -audience_seating_area_for_gymnasium_lighting,level_3_lighting_90_1_2004,39,default,118 -audience_seating_area_for_motion_picture_theater_lighting,level_3_lighting_90_1_2004,40,default,118 -audience_seating_area_for_penitentiary_lighting,level_3_lighting_90_1_2004,41,default,355 -audience_seating_area_for_performing_arts_theater_lighting,level_3_lighting_90_1_2004,42,default,426 -audience_seating_area_for_religious_buildings_lighting,level_3_lighting_90_1_2004,43,default,118 -audience_seating_area_for_sports_arena_lighting,level_3_lighting_90_1_2004,44,default,118 -classroom_lecture_training_for_penitentiary_lighting,level_3_lighting_90_1_2004,47,default,471 -corridor_transition_for_hospital_lighting,level_3_lighting_90_1_2004,50,default,355 -dining_area_for_penitentiary_lighting,level_3_lighting_90_1_2004,57,default,178 -dining_bar_lounge_leisure_general_lighting,level_3_lighting_90_1_2004,4,default,118 -dining_cafeteria_fast_food_general_lighting,level_3_lighting_90_1_2004,5,default,237 -dining_area_for_family_dining_lighting,level_3_lighting_90_1_2004,54,default,237 -lobby_for_hotel_lighting,level_3_lighting_90_1_2004,65,default,178 -lobby_for_motion_picture_theater_lighting,level_3_lighting_90_1_2004,66,default,118 -lobby_for_performing_arts_theater_lighting,level_3_lighting_90_1_2004,67,default,296 -lounge_recreation_for_hospital_lighting,level_3_lighting_90_1_2004,69,default,296 -office-enclosed_general_lighting,level_3_lighting_90_1_2004,71,default,355 -office_open_plan_lighting,level_3_lighting_90_1_2004,72,default,414 -automotive_general_lighting,level_3_lighting_90_1_2004,76,default,355 -convention_center_exhibit_space_general_lighting,level_3_lighting_90_1_2004,78,default,431 -library_reading_area_lighting,level_3_lighting_90_1_2004,101,default,592 -library_stacks_lighting,level_3_lighting_90_1_2004,102,default,355 -manufacturing_facility_detailed_manufacturing_area_lighting,level_3_lighting_90_1_2004,104,default,592 -manufacturing_facility_equipment_room_lighting,level_3_lighting_90_1_2004,105,default,237 -manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting,level_3_lighting_90_1_2004,106,default,592 -manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting,level_3_lighting_90_1_2004,107,default,592 -museum_restoration_room_lighting,level_3_lighting_90_1_2004,109,default,592 -post_office_sorting_area_general_lighting,level_3_lighting_90_1_2004,111,default,474 -religious_buildings_fellowship_hall_lighting,level_3_lighting_90_1_2004,112,default,355 -religious_buildings_worship_pulpit_choir_lighting,level_3_lighting_90_1_2004,113,default,355 -retail_mall_concourse_lighting,level_3_lighting_90_1_2004,114,default,403 -transportation_facility_ticket_counter_lighting,level_3_lighting_90_1_2004,123,default,296 -warehouse_storage_area_medium_to_bulky_palletized_items_lighting,level_3_lighting_90_1_2004,125,default,355 -warehouse_storage_area_smaller_hand-carried_items_lighting,level_3_lighting_90_1_2004,124,default,237 -airport_concourse_lighting,level_3_lighting_90_1_2007,125,default,118 -atrium_lighting,level_3_lighting_90_1_2007,36,default,178 -none_lighting,level_3_lighting_90_1_2007,129,default,0 -audience_seating_lighting,level_3_lighting_90_1_2007,46,default,118 -baggage_carousel_lighting,level_3_lighting_90_1_2007,124,default,237 -banking_lighting,level_3_lighting_90_1_2007,78,default,355 -classroom_lecture_training_lighting,level_3_lighting_90_1_2007,48,default,471 -computer_room_lighting,level_3_lighting_90_1_2007,48,default,710 -conference_meeting_multipurpose_lighting,level_3_lighting_90_1_2007,49,default,355 -confinement_cells_lighting,level_3_lighting_90_1_2007,80,default,296 -copy_print_lighting,level_3_lighting_90_1_2007,49,default,178 -corridor_lighting,level_3_lighting_90_1_2007,52,default,178 -courtroom_lighting,level_3_lighting_90_1_2007,81,default,474 -datacenterhighite_lighting,level_3_lighting_90_1_2007,60,default,118 -datacenterlowite_lighting,level_3_lighting_90_1_2007,60,default,118 -dining_lighting,level_3_lighting_90_1_2007,58,default,308 -dressing_room_lighting,level_3_lighting_90_1_2007,59,default,237 -electrical_mechanical_lighting,level_3_lighting_90_1_2007,60,default,118 -emergency_room_lighting,level_3_lighting_90_1_2007,88,default,888 -emergency_vehicle_garage_lighting,level_3_lighting_90_1_2007,84,default,355 -exam_treatment_lighting,level_3_lighting_90_1_2007,89,default,592 -exercise_area_lighting,level_3_lighting_90_1_2007,86,default,474 -exhibit_lighting,level_3_lighting_90_1_2007,109,default,431 -guest_room_lighting,level_3_lighting_90_1_2007,100,default,178 -imaging_lighting,level_3_lighting_90_1_2007,98,default,355 -interior_parking_lighting,level_3_lighting_90_1_2007,111,default,54 -judges_chambers_lighting,level_3_lighting_90_1_2007,82,default,355 -food_preparation_lighting,level_3_lighting_90_1_2007,61,default,538 -laboratory_lighting,level_3_lighting_90_1_2007,64,default,592 -laundry_washing_lighting,level_3_lighting_90_1_2007,90,default,355 -library_lighting,level_3_lighting_90_1_2007,13,default,118 -living_quarters_lighting,level_3_lighting_90_1_2007,83,default,178 -loading_dock_lighting,level_3_lighting_90_1_2007,30,default,355 -lobby_lighting,level_3_lighting_90_1_2007,68,default,296 -locker_room_lighting,level_3_lighting_90_1_2007,59,default,237 -lounge_breakroom_lighting,level_3_lighting_90_1_2007,70,default,178 -manufacturing_lighting,level_3_lighting_90_1_2007,14,default,592 -medical_supply_lighting,level_3_lighting_90_1_2007,91,default,355 -multifamily_lighting,level_3_lighting_90_1_2007,17,default,178 -nursery_lighting,level_3_lighting_90_1_2007,93,default,355 -nurses_station_lighting,level_3_lighting_90_1_2007,92,default,355 -office_lighting,level_3_lighting_90_1_2007,19,default,414 -office_enclosed_lighting,level_3_lighting_90_1_2007,71,default,355 -operating_room_lighting,level_3_lighting_90_1_2007,94,default,1184 -patient_room_lighting,level_3_lighting_90_1_2007,95,default,355 -pharmacy_lighting,level_3_lighting_90_1_2007,96,default,888 -physical_therapy_lighting,level_3_lighting_90_1_2007,97,default,474 -playing_area_lighting,level_3_lighting_90_1_2007,87,default,592 -post_office_lighting,level_3_lighting_90_1_2007,24,default,237 -recovery_lighting,level_3_lighting_90_1_2007,99,default,592 -recreation_common_living_lighting,level_3_lighting_90_1_2007,70,default,323 -restroom_lighting,level_3_lighting_90_1_2007,73,default,178 -retail_sales_lighting,level_3_lighting_90_1_2007,120,default,474 -sleeping_quarters_lighting,level_3_lighting_90_1_2007,85,default,59 -sports_arena_lighting,level_3_lighting_90_1_2007,28,default,1184 -stairwell_lighting,level_3_lighting_90_1_2007,75,default,118 -storage_lighting,level_3_lighting_90_1_2007,34,default,118 -transportation_lighting,level_3_lighting_90_1_2007,30,default,237 -vehicular_maintenance_lighting,level_3_lighting_90_1_2007,77,default,355 -workshop_lighting,level_3_lighting_90_1_2007,32,default,592 -worship_lighting,level_3_lighting_90_1_2007,25,default,355 -ba_automotive_facility_lighting,level_3_lighting_90_1_2007,1,default,355 -ba_convention_center_lighting,level_3_lighting_90_1_2007,2,default,118 -ba_courthouse_lighting,level_3_lighting_90_1_2007,3,default,474 -ba_dining_bar_lounge_leisure_lighting,level_3_lighting_90_1_2007,4,default,118 -ba_dining_cafeteria_fast_food_lighting,level_3_lighting_90_1_2007,5,default,237 -ba_dining_family_lighting,level_3_lighting_90_1_2007,6,default,237 -ba_dormitory_lighting,level_3_lighting_90_1_2007,7,default,178 -ba_exercise_center_lighting,level_3_lighting_90_1_2007,8,default,237 -ba_fire_station_lighting,level_3_lighting_90_1_2007,23,default,118 -ba_gymnasium_lighting,level_3_lighting_90_1_2007,9,default,237 -ba_health-care_clinic_lighting,level_3_lighting_90_1_2007,10,default,592 -ba_hospital_lighting,level_3_lighting_90_1_2007,11,default,592 -ba_hotel_motel_lighting,level_3_lighting_90_1_2007,12,default,178 -ba_motion_picture_theater_lighting,level_3_lighting_90_1_2007,16,default,118 -ba_museum_lighting,level_3_lighting_90_1_2007,18,default,118 -ba_parking_garage_lighting,level_3_lighting_90_1_2007,20,default,54 -ba_penitentiary_lighting,level_3_lighting_90_1_2007,21,default,296 -ba_performing_arts_theater_lighting,level_3_lighting_90_1_2007,22,default,426 -ba_police_station_lighting,level_3_lighting_90_1_2007,23,default,118 -ba_school_university_lighting,level_3_lighting_90_1_2007,27,default,471 -ba_town_hall_lighting,level_3_lighting_90_1_2007,29,default,355 -ba_retail_lighting,level_3_lighting_90_1_2007,26,default,474 -ba_warehouse_lighting,level_3_lighting_90_1_2007,31,default,118 -audience_seating_area_for_gymnasium_lighting,level_3_lighting_90_1_2007,39,default,118 -audience_seating_area_for_motion_picture_theater_lighting,level_3_lighting_90_1_2007,40,default,118 -audience_seating_area_for_penitentiary_lighting,level_3_lighting_90_1_2007,41,default,355 -audience_seating_area_for_performing_arts_theater_lighting,level_3_lighting_90_1_2007,42,default,426 -audience_seating_area_for_religious_buildings_lighting,level_3_lighting_90_1_2007,43,default,118 -audience_seating_area_for_sports_arena_lighting,level_3_lighting_90_1_2007,44,default,118 -classroom_lecture_training_for_penitentiary_lighting,level_3_lighting_90_1_2007,47,default,471 -corridor_transition_for_hospital_lighting,level_3_lighting_90_1_2007,50,default,355 -dining_area_for_penitentiary_lighting,level_3_lighting_90_1_2007,57,default,178 -dining_bar_lounge_leisure_general_lighting,level_3_lighting_90_1_2007,4,default,118 -dining_cafeteria_fast_food_general_lighting,level_3_lighting_90_1_2007,5,default,237 -dining_area_for_family_dining_lighting,level_3_lighting_90_1_2007,54,default,237 -lobby_for_hotel_lighting,level_3_lighting_90_1_2007,65,default,178 -lobby_for_motion_picture_theater_lighting,level_3_lighting_90_1_2007,66,default,118 -lobby_for_performing_arts_theater_lighting,level_3_lighting_90_1_2007,67,default,296 -lounge_recreation_for_hospital_lighting,level_3_lighting_90_1_2007,69,default,296 -office-enclosed_general_lighting,level_3_lighting_90_1_2007,71,default,355 -office_open_plan_lighting,level_3_lighting_90_1_2007,72,default,414 -automotive_general_lighting,level_3_lighting_90_1_2007,77,default,355 -convention_center_exhibit_space_general_lighting,level_3_lighting_90_1_2007,79,default,431 -library_reading_area_lighting,level_3_lighting_90_1_2007,102,default,592 -library_stacks_lighting,level_3_lighting_90_1_2007,103,default,355 -manufacturing_facility_detailed_manufacturing_area_lighting,level_3_lighting_90_1_2007,105,default,592 -manufacturing_facility_equipment_room_lighting,level_3_lighting_90_1_2007,106,default,237 -manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting,level_3_lighting_90_1_2007,107,default,592 -manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting,level_3_lighting_90_1_2007,108,default,592 -museum_restoration_room_lighting,level_3_lighting_90_1_2007,110,default,592 -post_office_sorting_area_general_lighting,level_3_lighting_90_1_2007,112,default,474 -religious_buildings_fellowship_hall_lighting,level_3_lighting_90_1_2007,113,default,355 -religious_buildings_worship_pulpit_choir_lighting,level_3_lighting_90_1_2007,114,default,355 -retail_mall_concourse_lighting,level_3_lighting_90_1_2007,115,default,403 -transportation_facility_ticket_counter_lighting,level_3_lighting_90_1_2007,126,default,296 -warehouse_storage_area_medium_to_bulky_palletized_items_lighting,level_3_lighting_90_1_2007,128,default,355 -warehouse_storage_area_smaller_hand-carried_items_lighting,level_3_lighting_90_1_2007,127,default,237 -airport_concourse_lighting,level_3_lighting_90_1_2010,128,default,118 -atrium_lighting,level_3_lighting_90_1_2010,34,default,178 -none_lighting,level_3_lighting_90_1_2010,133,default,0 -audience_seating_lighting,level_3_lighting_90_1_2010,36,default,118 -baggage_carousel_lighting,level_3_lighting_90_1_2010,127,default,237 -banking_lighting,level_3_lighting_90_1_2010,64,default,355 -classroom_lecture_training_lighting,level_3_lighting_90_1_2010,39,default,471 -computer_room_lighting,level_3_lighting_90_1_2010,39,default,710 -conference_meeting_multipurpose_lighting,level_3_lighting_90_1_2010,40,default,355 -confinement_cells_lighting,level_3_lighting_90_1_2010,67,default,296 -copy_print_lighting,level_3_lighting_90_1_2010,40,default,178 -corridor_lighting,level_3_lighting_90_1_2010,41,default,178 -courtroom_lighting,level_3_lighting_90_1_2010,68,default,474 -datacenterhighite_lighting,level_3_lighting_90_1_2010,46,default,118 -datacenterlowite_lighting,level_3_lighting_90_1_2010,46,default,118 -dining_lighting,level_3_lighting_90_1_2010,44,default,308 -dressing_room_lighting,level_3_lighting_90_1_2010,113,default,237 -electrical_mechanical_lighting,level_3_lighting_90_1_2010,46,default,118 -emergency_room_lighting,level_3_lighting_90_1_2010,80,default,888 -emergency_vehicle_garage_lighting,level_3_lighting_90_1_2010,74,default,355 -exam_treatment_lighting,level_3_lighting_90_1_2010,81,default,592 -exercise_area_lighting,level_3_lighting_90_1_2010,76,default,474 -exhibit_lighting,level_3_lighting_90_1_2010,107,default,431 -guest_room_lighting,level_3_lighting_90_1_2010,96,default,178 -imaging_lighting,level_3_lighting_90_1_2010,91,default,355 -interior_parking_lighting,level_3_lighting_90_1_2010,109,default,54 -judges_chambers_lighting,level_3_lighting_90_1_2010,69,default,355 -food_preparation_lighting,level_3_lighting_90_1_2010,47,default,538 -laboratory_lighting,level_3_lighting_90_1_2010,49,default,592 -laundry_washing_lighting,level_3_lighting_90_1_2010,82,default,355 -library_lighting,level_3_lighting_90_1_2010,14,default,118 -living_quarters_lighting,level_3_lighting_90_1_2010,73,default,178 -loading_dock_lighting,level_3_lighting_90_1_2010,31,default,355 -lobby_lighting,level_3_lighting_90_1_2010,53,default,296 -locker_room_lighting,level_3_lighting_90_1_2010,54,default,237 -lounge_breakroom_lighting,level_3_lighting_90_1_2010,55,default,178 -manufacturing_lighting,level_3_lighting_90_1_2010,15,default,592 -medical_supply_lighting,level_3_lighting_90_1_2010,84,default,355 -multifamily_lighting,level_3_lighting_90_1_2010,18,default,178 -nursery_lighting,level_3_lighting_90_1_2010,85,default,355 -nurses_station_lighting,level_3_lighting_90_1_2010,86,default,355 -office_lighting,level_3_lighting_90_1_2010,20,default,414 -office_enclosed_lighting,level_3_lighting_90_1_2010,56,default,355 -operating_room_lighting,level_3_lighting_90_1_2010,87,default,1184 -patient_room_lighting,level_3_lighting_90_1_2010,88,default,355 -pharmacy_lighting,level_3_lighting_90_1_2010,89,default,888 -physical_therapy_lighting,level_3_lighting_90_1_2010,90,default,474 -playing_area_lighting,level_3_lighting_90_1_2010,78,default,592 -post_office_lighting,level_3_lighting_90_1_2010,25,default,237 -recovery_lighting,level_3_lighting_90_1_2010,92,default,592 -recreation_common_living_lighting,level_3_lighting_90_1_2010,55,default,323 -restroom_lighting,level_3_lighting_90_1_2010,58,default,178 -retail_sales_lighting,level_3_lighting_90_1_2010,119,default,474 -sleeping_quarters_lighting,level_3_lighting_90_1_2010,75,default,59 -sports_arena_lighting,level_3_lighting_90_1_2010,29,default,1184 -stairwell_lighting,level_3_lighting_90_1_2010,60,default,118 -storage_lighting,level_3_lighting_90_1_2010,61,default,118 -transportation_lighting,level_3_lighting_90_1_2010,31,default,237 -vehicular_maintenance_lighting,level_3_lighting_90_1_2010,63,default,355 -workshop_lighting,level_3_lighting_90_1_2010,33,default,592 -worship_lighting,level_3_lighting_90_1_2010,26,default,355 -ba_automotive_facility_lighting,level_3_lighting_90_1_2010,1,default,355 -ba_convention_center_lighting,level_3_lighting_90_1_2010,2,default,118 -ba_courthouse_lighting,level_3_lighting_90_1_2010,3,default,474 -ba_dining_bar_lounge_leisure_lighting,level_3_lighting_90_1_2010,4,default,118 -ba_dining_cafeteria_fast_food_lighting,level_3_lighting_90_1_2010,5,default,237 -ba_dining_family_lighting,level_3_lighting_90_1_2010,6,default,237 -ba_dormitory_lighting,level_3_lighting_90_1_2010,7,default,178 -ba_exercise_center_lighting,level_3_lighting_90_1_2010,8,default,237 -ba_fire_station_lighting,level_3_lighting_90_1_2010,9,default,118 -ba_gymnasium_lighting,level_3_lighting_90_1_2010,10,default,237 -ba_health-care_clinic_lighting,level_3_lighting_90_1_2010,11,default,592 -ba_hospital_lighting,level_3_lighting_90_1_2010,12,default,592 -ba_hotel_motel_lighting,level_3_lighting_90_1_2010,13,default,178 -ba_motion_picture_theater_lighting,level_3_lighting_90_1_2010,17,default,118 -ba_museum_lighting,level_3_lighting_90_1_2010,19,default,118 -ba_parking_garage_lighting,level_3_lighting_90_1_2010,21,default,54 -ba_penitentiary_lighting,level_3_lighting_90_1_2010,22,default,296 -ba_performing_arts_theater_lighting,level_3_lighting_90_1_2010,23,default,426 -ba_police_station_lighting,level_3_lighting_90_1_2010,24,default,118 -ba_school_university_lighting,level_3_lighting_90_1_2010,28,default,471 -ba_town_hall_lighting,level_3_lighting_90_1_2010,30,default,355 -ba_retail_lighting,level_3_lighting_90_1_2010,27,default,474 -ba_warehouse_lighting,level_3_lighting_90_1_2010,32,default,118 -audience_seating_area_for_gymnasium_lighting,level_3_lighting_90_1_2010,77,default,118 -audience_seating_area_for_motion_picture_theater_lighting,level_3_lighting_90_1_2010,37,default,118 -audience_seating_area_for_penitentiary_lighting,level_3_lighting_90_1_2010,70,default,355 -audience_seating_area_for_performing_arts_theater_lighting,level_3_lighting_90_1_2010,38,default,426 -audience_seating_area_for_religious_buildings_lighting,level_3_lighting_90_1_2010,110,default,118 -audience_seating_area_for_sports_arena_lighting,level_3_lighting_90_1_2010,120,default,118 -classroom_lecture_training_for_penitentiary_lighting,level_3_lighting_90_1_2010,71,default,471 -corridor_transition_for_hospital_lighting,level_3_lighting_90_1_2010,79,default,355 -dining_area_for_penitentiary_lighting,level_3_lighting_90_1_2010,72,default,178 -dining_bar_lounge_leisure_general_lighting,level_3_lighting_90_1_2010,4,default,118 -dining_cafeteria_fast_food_general_lighting,level_3_lighting_90_1_2010,5,default,237 -dining_area_for_family_dining_lighting,level_3_lighting_90_1_2010,43,default,237 -lobby_for_hotel_lighting,level_3_lighting_90_1_2010,97,default,178 -lobby_for_motion_picture_theater_lighting,level_3_lighting_90_1_2010,51,default,118 -lobby_for_performing_arts_theater_lighting,level_3_lighting_90_1_2010,52,default,296 -lounge_recreation_for_hospital_lighting,level_3_lighting_90_1_2010,83,default,296 -office-enclosed_general_lighting,level_3_lighting_90_1_2010,56,default,355 -office_open_plan_lighting,level_3_lighting_90_1_2010,57,default,414 -automotive_general_lighting,level_3_lighting_90_1_2010,63,default,355 -convention_center_exhibit_space_general_lighting,level_3_lighting_90_1_2010,66,default,431 -library_reading_area_lighting,level_3_lighting_90_1_2010,99,default,592 -library_stacks_lighting,level_3_lighting_90_1_2010,100,default,355 -manufacturing_facility_detailed_manufacturing_area_lighting,level_3_lighting_90_1_2010,102,default,592 -manufacturing_facility_equipment_room_lighting,level_3_lighting_90_1_2010,103,default,237 -manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting,level_3_lighting_90_1_2010,105,default,592 -manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting,level_3_lighting_90_1_2010,106,default,592 -museum_restoration_room_lighting,level_3_lighting_90_1_2010,108,default,592 -post_office_sorting_area_general_lighting,level_3_lighting_90_1_2010,126,default,474 -religious_buildings_fellowship_hall_lighting,level_3_lighting_90_1_2010,111,default,355 -religious_buildings_worship_pulpit_choir_lighting,level_3_lighting_90_1_2010,112,default,355 -retail_mall_concourse_lighting,level_3_lighting_90_1_2010,114,default,403 -transportation_facility_ticket_counter_lighting,level_3_lighting_90_1_2010,130,default,296 -warehouse_storage_area_medium_to_bulky_palletized_items_lighting,level_3_lighting_90_1_2010,132,default,355 -warehouse_storage_area_smaller_hand-carried_items_lighting,level_3_lighting_90_1_2010,131,default,237 -airport_concourse_lighting,level_3_lighting_90_1_2013,140,default,118 -atrium_lighting,level_3_lighting_90_1_2013,33,default,178 -none_lighting,level_3_lighting_90_1_2013,143,default,0 -audience_seating_lighting,level_3_lighting_90_1_2013,36,default,118 -baggage_carousel_lighting,level_3_lighting_90_1_2013,139,default,237 -banking_lighting,level_3_lighting_90_1_2013,45,default,355 -classroom_lecture_training_lighting,level_3_lighting_90_1_2013,47,default,471 -computer_room_lighting,level_3_lighting_90_1_2013,49,default,710 -conference_meeting_multipurpose_lighting,level_3_lighting_90_1_2013,50,default,355 -confinement_cells_lighting,level_3_lighting_90_1_2013,51,default,296 -copy_print_lighting,level_3_lighting_90_1_2013,52,default,178 -corridor_lighting,level_3_lighting_90_1_2013,53,default,178 -courtroom_lighting,level_3_lighting_90_1_2013,57,default,474 -datacenterhighite_lighting,level_3_lighting_90_1_2013,64,default,118 -datacenterlowite_lighting,level_3_lighting_90_1_2013,64,default,118 -dining_lighting,level_3_lighting_90_1_2013,58,default,308 -dressing_room_lighting,level_3_lighting_90_1_2013,128,default,237 -electrical_mechanical_lighting,level_3_lighting_90_1_2013,64,default,118 -emergency_room_lighting,level_3_lighting_90_1_2013,112,default,888 -emergency_vehicle_garage_lighting,level_3_lighting_90_1_2013,65,default,355 -exam_treatment_lighting,level_3_lighting_90_1_2013,112,default,592 -exercise_area_lighting,level_3_lighting_90_1_2013,105,default,474 -exhibit_lighting,level_3_lighting_90_1_2013,122,default,431 -guest_room_lighting,level_3_lighting_90_1_2013,67,default,178 -imaging_lighting,level_3_lighting_90_1_2013,113,default,355 -interior_parking_lighting,level_3_lighting_90_1_2013,84,default,54 -judges_chambers_lighting,level_3_lighting_90_1_2013,57,default,355 -food_preparation_lighting,level_3_lighting_90_1_2013,66,default,538 -laboratory_lighting,level_3_lighting_90_1_2013,68,default,592 -laundry_washing_lighting,level_3_lighting_90_1_2013,70,default,355 -library_lighting,level_3_lighting_90_1_2013,14,default,118 -living_quarters_lighting,level_3_lighting_90_1_2013,99,default,178 -loading_dock_lighting,level_3_lighting_90_1_2013,71,default,355 -lobby_lighting,level_3_lighting_90_1_2013,72,default,296 -locker_room_lighting,level_3_lighting_90_1_2013,78,default,237 -lounge_breakroom_lighting,level_3_lighting_90_1_2013,46,default,178 -manufacturing_lighting,level_3_lighting_90_1_2013,15,default,592 -medical_supply_lighting,level_3_lighting_90_1_2013,106,default,355 -multifamily_lighting,level_3_lighting_90_1_2013,17,default,178 -nursery_lighting,level_3_lighting_90_1_2013,108,default,355 -nurses_station_lighting,level_3_lighting_90_1_2013,107,default,355 -office_lighting,level_3_lighting_90_1_2013,19,default,414 -office_enclosed_lighting,level_3_lighting_90_1_2013,81,default,355 -operating_room_lighting,level_3_lighting_90_1_2013,114,default,1184 -patient_room_lighting,level_3_lighting_90_1_2013,109,default,355 -pharmacy_lighting,level_3_lighting_90_1_2013,106,default,888 -physical_therapy_lighting,level_3_lighting_90_1_2013,110,default,474 -playing_area_lighting,level_3_lighting_90_1_2013,104,default,592 -post_office_lighting,level_3_lighting_90_1_2013,24,default,237 -recovery_lighting,level_3_lighting_90_1_2013,111,default,592 -recreation_common_living_lighting,level_3_lighting_90_1_2013,79,default,323 -restroom_lighting,level_3_lighting_90_1_2013,86,default,178 -retail_sales_lighting,level_3_lighting_90_1_2013,88,default,474 -sleeping_quarters_lighting,level_3_lighting_90_1_2013,103,default,59 -sports_arena_lighting,level_3_lighting_90_1_2013,28,default,1184 -stairwell_lighting,level_3_lighting_90_1_2013,91,default,118 -storage_lighting,level_3_lighting_90_1_2013,94,default,118 -transportation_lighting,level_3_lighting_90_1_2013,30,default,237 -vehicular_maintenance_lighting,level_3_lighting_90_1_2013,95,default,355 -workshop_lighting,level_3_lighting_90_1_2013,32,default,592 -worship_lighting,level_3_lighting_90_1_2013,25,default,355 -ba_automotive_facility_lighting,level_3_lighting_90_1_2013,1,default,355 -ba_convention_center_lighting,level_3_lighting_90_1_2013,2,default,118 -ba_courthouse_lighting,level_3_lighting_90_1_2013,3,default,474 -ba_dining_bar_lounge_leisure_lighting,level_3_lighting_90_1_2013,4,default,118 -ba_dining_cafeteria_fast_food_lighting,level_3_lighting_90_1_2013,5,default,237 -ba_dining_family_lighting,level_3_lighting_90_1_2013,6,default,237 -ba_dormitory_lighting,level_3_lighting_90_1_2013,7,default,178 -ba_exercise_center_lighting,level_3_lighting_90_1_2013,8,default,237 -ba_fire_station_lighting,level_3_lighting_90_1_2013,9,default,118 -ba_gymnasium_lighting,level_3_lighting_90_1_2013,10,default,237 -ba_health-care_clinic_lighting,level_3_lighting_90_1_2013,11,default,592 -ba_hospital_lighting,level_3_lighting_90_1_2013,12,default,592 -ba_hotel_motel_lighting,level_3_lighting_90_1_2013,13,default,178 -ba_motion_picture_theater_lighting,level_3_lighting_90_1_2013,16,default,118 -ba_museum_lighting,level_3_lighting_90_1_2013,18,default,118 -ba_parking_garage_lighting,level_3_lighting_90_1_2013,20,default,54 -ba_penitentiary_lighting,level_3_lighting_90_1_2013,21,default,296 -ba_performing_arts_theater_lighting,level_3_lighting_90_1_2013,22,default,426 -ba_police_station_lighting,level_3_lighting_90_1_2013,23,default,118 -ba_school_university_lighting,level_3_lighting_90_1_2013,27,default,471 -ba_town_hall_lighting,level_3_lighting_90_1_2013,29,default,355 -ba_retail_lighting,level_3_lighting_90_1_2013,26,default,474 -ba_warehouse_lighting,level_3_lighting_90_1_2013,31,default,118 -audience_seating_area_for_gymnasium_lighting,level_3_lighting_90_1_2013,38,default,118 -audience_seating_area_for_motion_picture_theater_lighting,level_3_lighting_90_1_2013,39,default,118 -audience_seating_area_for_penitentiary_lighting,level_3_lighting_90_1_2013,40,default,355 -audience_seating_area_for_performing_arts_theater_lighting,level_3_lighting_90_1_2013,41,default,426 -audience_seating_area_for_religious_buildings_lighting,level_3_lighting_90_1_2013,42,default,118 -audience_seating_area_for_sports_arena_lighting,level_3_lighting_90_1_2013,43,default,118 -classroom_lecture_training_for_penitentiary_lighting,level_3_lighting_90_1_2013,48,default,471 -corridor_transition_for_hospital_lighting,level_3_lighting_90_1_2013,55,default,355 -dining_area_for_penitentiary_lighting,level_3_lighting_90_1_2013,60,default,178 -dining_bar_lounge_leisure_general_lighting,level_3_lighting_90_1_2013,4,default,118 -dining_cafeteria_fast_food_general_lighting,level_3_lighting_90_1_2013,5,default,237 -dining_area_for_family_dining_lighting,level_3_lighting_90_1_2013,63,default,237 -lobby_for_hotel_lighting,level_3_lighting_90_1_2013,75,default,178 -lobby_for_motion_picture_theater_lighting,level_3_lighting_90_1_2013,76,default,118 -lobby_for_performing_arts_theater_lighting,level_3_lighting_90_1_2013,77,default,296 -lounge_recreation_for_hospital_lighting,level_3_lighting_90_1_2013,80,default,296 -office-enclosed_general_lighting,level_3_lighting_90_1_2013,81,default,355 -office_open_plan_lighting,level_3_lighting_90_1_2013,83,default,414 -automotive_general_lighting,level_3_lighting_90_1_2013,97,default,355 -convention_center_exhibit_space_general_lighting,level_3_lighting_90_1_2013,98,default,431 -library_reading_area_lighting,level_3_lighting_90_1_2013,115,default,592 -library_stacks_lighting,level_3_lighting_90_1_2013,116,default,355 -manufacturing_facility_detailed_manufacturing_area_lighting,level_3_lighting_90_1_2013,117,default,592 -manufacturing_facility_equipment_room_lighting,level_3_lighting_90_1_2013,120,default,237 -manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting,level_3_lighting_90_1_2013,118,default,592 -manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting,level_3_lighting_90_1_2013,119,default,592 -museum_restoration_room_lighting,level_3_lighting_90_1_2013,123,default,592 -post_office_sorting_area_general_lighting,level_3_lighting_90_1_2013,125,default,474 -religious_buildings_fellowship_hall_lighting,level_3_lighting_90_1_2013,127,default,355 -religious_buildings_worship_pulpit_choir_lighting,level_3_lighting_90_1_2013,126,default,355 -retail_mall_concourse_lighting,level_3_lighting_90_1_2013,129,default,403 -transportation_facility_ticket_counter_lighting,level_3_lighting_90_1_2013,138,default,296 -warehouse_storage_area_medium_to_bulky_palletized_items_lighting,level_3_lighting_90_1_2013,141,default,355 -warehouse_storage_area_smaller_hand-carried_items_lighting,level_3_lighting_90_1_2013,142,default,237 -airport_concourse_lighting,level_3_lighting_90_1_2016,137,default,118 -atrium_lighting,level_3_lighting_90_1_2016,33,default,178 -none_lighting,level_3_lighting_90_1_2016,142,default,0 -audience_seating_lighting,level_3_lighting_90_1_2016,36,default,118 -baggage_carousel_lighting,level_3_lighting_90_1_2016,138,default,237 -banking_lighting,level_3_lighting_90_1_2016,45,default,355 -classroom_lecture_training_lighting,level_3_lighting_90_1_2016,47,default,471 -computer_room_lighting,level_3_lighting_90_1_2016,49,default,710 -conference_meeting_multipurpose_lighting,level_3_lighting_90_1_2016,50,default,355 -confinement_cells_lighting,level_3_lighting_90_1_2016,51,default,296 -copy_print_lighting,level_3_lighting_90_1_2016,52,default,178 -corridor_lighting,level_3_lighting_90_1_2016,53,default,178 -courtroom_lighting,level_3_lighting_90_1_2016,57,default,474 -datacenterhighite_lighting,level_3_lighting_90_1_2016,64,default,118 -datacenterlowite_lighting,level_3_lighting_90_1_2016,64,default,118 -dining_lighting,level_3_lighting_90_1_2016,58,default,308 -dressing_room_lighting,level_3_lighting_90_1_2016,127,default,237 -electrical_mechanical_lighting,level_3_lighting_90_1_2016,64,default,118 -emergency_room_lighting,level_3_lighting_90_1_2016,105,default,888 -emergency_vehicle_garage_lighting,level_3_lighting_90_1_2016,65,default,355 -exam_treatment_lighting,level_3_lighting_90_1_2016,105,default,592 -exercise_area_lighting,level_3_lighting_90_1_2016,103,default,474 -exhibit_lighting,level_3_lighting_90_1_2016,121,default,431 -guest_room_lighting,level_3_lighting_90_1_2016,67,default,178 -imaging_lighting,level_3_lighting_90_1_2016,106,default,355 -interior_parking_lighting,level_3_lighting_90_1_2016,84,default,54 -judges_chambers_lighting,level_3_lighting_90_1_2016,57,default,355 -food_preparation_lighting,level_3_lighting_90_1_2016,66,default,538 -laboratory_lighting,level_3_lighting_90_1_2016,68,default,592 -laundry_washing_lighting,level_3_lighting_90_1_2016,70,default,355 -library_lighting,level_3_lighting_90_1_2016,14,default,118 -living_quarters_lighting,level_3_lighting_90_1_2016,99,default,178 -loading_dock_lighting,level_3_lighting_90_1_2016,71,default,355 -lobby_lighting,level_3_lighting_90_1_2016,72,default,296 -locker_room_lighting,level_3_lighting_90_1_2016,78,default,237 -lounge_breakroom_lighting,level_3_lighting_90_1_2016,46,default,178 -manufacturing_lighting,level_3_lighting_90_1_2016,15,default,592 -medical_supply_lighting,level_3_lighting_90_1_2016,107,default,355 -multifamily_lighting,level_3_lighting_90_1_2016,17,default,178 -nursery_lighting,level_3_lighting_90_1_2016,109,default,355 -nurses_station_lighting,level_3_lighting_90_1_2016,108,default,355 -office_lighting,level_3_lighting_90_1_2016,19,default,414 -office_enclosed_lighting,level_3_lighting_90_1_2016,81,default,355 -operating_room_lighting,level_3_lighting_90_1_2016,110,default,1184 -patient_room_lighting,level_3_lighting_90_1_2016,111,default,355 -pharmacy_lighting,level_3_lighting_90_1_2016,107,default,888 -physical_therapy_lighting,level_3_lighting_90_1_2016,112,default,474 -playing_area_lighting,level_3_lighting_90_1_2016,104,default,592 -post_office_lighting,level_3_lighting_90_1_2016,24,default,237 -recovery_lighting,level_3_lighting_90_1_2016,113,default,592 -recreation_common_living_lighting,level_3_lighting_90_1_2016,79,default,323 -restroom_lighting,level_3_lighting_90_1_2016,86,default,178 -retail_sales_lighting,level_3_lighting_90_1_2016,88,default,474 -sleeping_quarters_lighting,level_3_lighting_90_1_2016,102,default,59 -sports_arena_lighting,level_3_lighting_90_1_2016,28,default,1184 -stairwell_lighting,level_3_lighting_90_1_2016,91,default,118 -storage_lighting,level_3_lighting_90_1_2016,94,default,118 -transportation_lighting,level_3_lighting_90_1_2016,30,default,237 -vehicular_maintenance_lighting,level_3_lighting_90_1_2016,95,default,355 -workshop_lighting,level_3_lighting_90_1_2016,32,default,592 -worship_lighting,level_3_lighting_90_1_2016,25,default,355 -ba_automotive_facility_lighting,level_3_lighting_90_1_2016,1,default,355 -ba_convention_center_lighting,level_3_lighting_90_1_2016,2,default,118 -ba_courthouse_lighting,level_3_lighting_90_1_2016,3,default,474 -ba_dining_bar_lounge_leisure_lighting,level_3_lighting_90_1_2016,4,default,118 -ba_dining_cafeteria_fast_food_lighting,level_3_lighting_90_1_2016,5,default,237 -ba_dining_family_lighting,level_3_lighting_90_1_2016,6,default,237 -ba_dormitory_lighting,level_3_lighting_90_1_2016,7,default,178 -ba_exercise_center_lighting,level_3_lighting_90_1_2016,8,default,237 -ba_fire_station_lighting,level_3_lighting_90_1_2016,9,default,118 -ba_gymnasium_lighting,level_3_lighting_90_1_2016,10,default,237 -ba_health-care_clinic_lighting,level_3_lighting_90_1_2016,11,default,592 -ba_hospital_lighting,level_3_lighting_90_1_2016,12,default,592 -ba_hotel_motel_lighting,level_3_lighting_90_1_2016,13,default,178 -ba_motion_picture_theater_lighting,level_3_lighting_90_1_2016,16,default,118 -ba_museum_lighting,level_3_lighting_90_1_2016,18,default,118 -ba_parking_garage_lighting,level_3_lighting_90_1_2016,20,default,54 -ba_penitentiary_lighting,level_3_lighting_90_1_2016,21,default,296 -ba_performing_arts_theater_lighting,level_3_lighting_90_1_2016,22,default,426 -ba_police_station_lighting,level_3_lighting_90_1_2016,23,default,118 -ba_school_university_lighting,level_3_lighting_90_1_2016,27,default,471 -ba_town_hall_lighting,level_3_lighting_90_1_2016,29,default,355 -ba_retail_lighting,level_3_lighting_90_1_2016,26,default,474 -ba_warehouse_lighting,level_3_lighting_90_1_2016,31,default,118 -audience_seating_area_for_gymnasium_lighting,level_3_lighting_90_1_2016,39,default,118 -audience_seating_area_for_motion_picture_theater_lighting,level_3_lighting_90_1_2016,40,default,118 -audience_seating_area_for_penitentiary_lighting,level_3_lighting_90_1_2016,41,default,355 -audience_seating_area_for_performing_arts_theater_lighting,level_3_lighting_90_1_2016,42,default,426 -audience_seating_area_for_religious_buildings_lighting,level_3_lighting_90_1_2016,43,default,118 -audience_seating_area_for_sports_arena_lighting,level_3_lighting_90_1_2016,44,default,118 -classroom_lecture_training_for_penitentiary_lighting,level_3_lighting_90_1_2016,48,default,471 -corridor_transition_for_hospital_lighting,level_3_lighting_90_1_2016,55,default,355 -dining_area_for_penitentiary_lighting,level_3_lighting_90_1_2016,61,default,178 -dining_bar_lounge_leisure_general_lighting,level_3_lighting_90_1_2016,4,default,118 -dining_cafeteria_fast_food_general_lighting,level_3_lighting_90_1_2016,5,default,237 -dining_area_for_family_dining_lighting,level_3_lighting_90_1_2016,62,default,237 -lobby_for_hotel_lighting,level_3_lighting_90_1_2016,75,default,178 -lobby_for_motion_picture_theater_lighting,level_3_lighting_90_1_2016,76,default,118 -lobby_for_performing_arts_theater_lighting,level_3_lighting_90_1_2016,77,default,296 -lounge_recreation_for_hospital_lighting,level_3_lighting_90_1_2016,80,default,296 -office-enclosed_general_lighting,level_3_lighting_90_1_2016,81,default,355 -office_open_plan_lighting,level_3_lighting_90_1_2016,83,default,414 -automotive_general_lighting,level_3_lighting_90_1_2016,97,default,355 -convention_center_exhibit_space_general_lighting,level_3_lighting_90_1_2016,98,default,431 -library_reading_area_lighting,level_3_lighting_90_1_2016,114,default,592 -library_stacks_lighting,level_3_lighting_90_1_2016,115,default,355 -manufacturing_facility_detailed_manufacturing_area_lighting,level_3_lighting_90_1_2016,116,default,592 -manufacturing_facility_equipment_room_lighting,level_3_lighting_90_1_2016,117,default,237 -manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting,level_3_lighting_90_1_2016,119,default,592 -manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting,level_3_lighting_90_1_2016,120,default,592 -museum_restoration_room_lighting,level_3_lighting_90_1_2016,122,default,592 -post_office_sorting_area_general_lighting,level_3_lighting_90_1_2016,124,default,474 -religious_buildings_fellowship_hall_lighting,level_3_lighting_90_1_2016,125,default,355 -religious_buildings_worship_pulpit_choir_lighting,level_3_lighting_90_1_2016,126,default,355 -retail_mall_concourse_lighting,level_3_lighting_90_1_2016,128,default,403 -transportation_facility_ticket_counter_lighting,level_3_lighting_90_1_2016,139,default,296 -warehouse_storage_area_medium_to_bulky_palletized_items_lighting,level_3_lighting_90_1_2016,140,default,355 -warehouse_storage_area_smaller_hand-carried_items_lighting,level_3_lighting_90_1_2016,141,default,237 -airport_concourse_lighting,level_3_lighting_90_1_2019,134,default,118 -atrium_lighting,level_3_lighting_90_1_2019,33,default,178 -none_lighting,level_3_lighting_90_1_2019,139,default,0 -audience_seating_lighting,level_3_lighting_90_1_2019,36,default,118 -baggage_carousel_lighting,level_3_lighting_90_1_2019,135,default,237 -banking_lighting,level_3_lighting_90_1_2019,44,default,355 -classroom_lecture_training_lighting,level_3_lighting_90_1_2019,46,default,471 -computer_room_lighting,level_3_lighting_90_1_2019,48,default,710 -conference_meeting_multipurpose_lighting,level_3_lighting_90_1_2019,49,default,355 -confinement_cells_lighting,level_3_lighting_90_1_2019,50,default,296 -copy_print_lighting,level_3_lighting_90_1_2019,51,default,178 -corridor_lighting,level_3_lighting_90_1_2019,52,default,178 -courtroom_lighting,level_3_lighting_90_1_2019,55,default,474 -datacenterhighite_lighting,level_3_lighting_90_1_2019,62,default,118 -datacenterlowite_lighting,level_3_lighting_90_1_2019,62,default,118 -dining_lighting,level_3_lighting_90_1_2019,56,default,308 -dressing_room_lighting,level_3_lighting_90_1_2019,124,default,237 -electrical_mechanical_lighting,level_3_lighting_90_1_2019,62,default,118 -emergency_room_lighting,level_3_lighting_90_1_2019,102,default,888 -emergency_vehicle_garage_lighting,level_3_lighting_90_1_2019,63,default,355 -exam_treatment_lighting,level_3_lighting_90_1_2019,102,default,592 -exercise_area_lighting,level_3_lighting_90_1_2019,100,default,474 -exhibit_lighting,level_3_lighting_90_1_2019,118,default,431 -guest_room_lighting,level_3_lighting_90_1_2019,65,default,178 -imaging_lighting,level_3_lighting_90_1_2019,103,default,355 -interior_parking_lighting,level_3_lighting_90_1_2019,82,default,54 -judges_chambers_lighting,level_3_lighting_90_1_2019,55,default,355 -food_preparation_lighting,level_3_lighting_90_1_2019,64,default,538 -laboratory_lighting,level_3_lighting_90_1_2019,66,default,592 -laundry_washing_lighting,level_3_lighting_90_1_2019,68,default,355 -library_lighting,level_3_lighting_90_1_2019,14,default,118 -living_quarters_lighting,level_3_lighting_90_1_2019,96,default,178 -loading_dock_lighting,level_3_lighting_90_1_2019,69,default,355 -lobby_lighting,level_3_lighting_90_1_2019,70,default,296 -locker_room_lighting,level_3_lighting_90_1_2019,76,default,237 -lounge_breakroom_lighting,level_3_lighting_90_1_2019,45,default,178 -manufacturing_lighting,level_3_lighting_90_1_2019,15,default,592 -medical_supply_lighting,level_3_lighting_90_1_2019,104,default,355 -multifamily_lighting,level_3_lighting_90_1_2019,17,default,178 -nursery_lighting,level_3_lighting_90_1_2019,105,default,355 -nurses_station_lighting,level_3_lighting_90_1_2019,106,default,355 -office_lighting,level_3_lighting_90_1_2019,19,default,414 -office_enclosed_lighting,level_3_lighting_90_1_2019,79,default,355 -operating_room_lighting,level_3_lighting_90_1_2019,107,default,1184 -patient_room_lighting,level_3_lighting_90_1_2019,108,default,355 -pharmacy_lighting,level_3_lighting_90_1_2019,104,default,888 -physical_therapy_lighting,level_3_lighting_90_1_2019,109,default,474 -playing_area_lighting,level_3_lighting_90_1_2019,101,default,592 -post_office_lighting,level_3_lighting_90_1_2019,24,default,237 -recovery_lighting,level_3_lighting_90_1_2019,110,default,592 -recreation_common_living_lighting,level_3_lighting_90_1_2019,77,default,323 -restroom_lighting,level_3_lighting_90_1_2019,84,default,178 -retail_sales_lighting,level_3_lighting_90_1_2019,86,default,474 -sleeping_quarters_lighting,level_3_lighting_90_1_2019,99,default,59 -sports_arena_lighting,level_3_lighting_90_1_2019,28,default,1184 -stairwell_lighting,level_3_lighting_90_1_2019,89,default,118 -storage_lighting,level_3_lighting_90_1_2019,91,default,118 -transportation_lighting,level_3_lighting_90_1_2019,30,default,237 -vehicular_maintenance_lighting,level_3_lighting_90_1_2019,92,default,355 -workshop_lighting,level_3_lighting_90_1_2019,32,default,592 -worship_lighting,level_3_lighting_90_1_2019,25,default,355 -ba_automotive_facility_lighting,level_3_lighting_90_1_2019,1,default,355 -ba_convention_center_lighting,level_3_lighting_90_1_2019,2,default,118 -ba_courthouse_lighting,level_3_lighting_90_1_2019,3,default,474 -ba_dining_bar_lounge_leisure_lighting,level_3_lighting_90_1_2019,4,default,118 -ba_dining_cafeteria_fast_food_lighting,level_3_lighting_90_1_2019,5,default,237 -ba_dining_family_lighting,level_3_lighting_90_1_2019,6,default,237 -ba_dormitory_lighting,level_3_lighting_90_1_2019,7,default,178 -ba_exercise_center_lighting,level_3_lighting_90_1_2019,8,default,237 -ba_fire_station_lighting,level_3_lighting_90_1_2019,9,default,118 -ba_gymnasium_lighting,level_3_lighting_90_1_2019,10,default,237 -ba_health-care_clinic_lighting,level_3_lighting_90_1_2019,11,default,592 -ba_hospital_lighting,level_3_lighting_90_1_2019,12,default,592 -ba_hotel_motel_lighting,level_3_lighting_90_1_2019,13,default,178 -ba_motion_picture_theater_lighting,level_3_lighting_90_1_2019,16,default,118 -ba_museum_lighting,level_3_lighting_90_1_2019,18,default,118 -ba_parking_garage_lighting,level_3_lighting_90_1_2019,20,default,54 -ba_penitentiary_lighting,level_3_lighting_90_1_2019,21,default,296 -ba_performing_arts_theater_lighting,level_3_lighting_90_1_2019,22,default,426 -ba_police_station_lighting,level_3_lighting_90_1_2019,23,default,118 -ba_school_university_lighting,level_3_lighting_90_1_2019,27,default,471 -ba_town_hall_lighting,level_3_lighting_90_1_2019,29,default,355 -ba_retail_lighting,level_3_lighting_90_1_2019,26,default,474 -ba_warehouse_lighting,level_3_lighting_90_1_2019,31,default,118 -audience_seating_area_for_gymnasium_lighting,level_3_lighting_90_1_2019,38,default,118 -audience_seating_area_for_motion_picture_theater_lighting,level_3_lighting_90_1_2019,39,default,118 -audience_seating_area_for_penitentiary_lighting,level_3_lighting_90_1_2019,40,default,355 -audience_seating_area_for_performing_arts_theater_lighting,level_3_lighting_90_1_2019,41,default,426 -audience_seating_area_for_religious_buildings_lighting,level_3_lighting_90_1_2019,42,default,118 -audience_seating_area_for_sports_arena_lighting,level_3_lighting_90_1_2019,43,default,118 -classroom_lecture_training_for_penitentiary_lighting,level_3_lighting_90_1_2019,47,default,471 -corridor_transition_for_hospital_lighting,level_3_lighting_90_1_2019,54,default,355 -dining_area_for_penitentiary_lighting,level_3_lighting_90_1_2019,61,default,178 -dining_bar_lounge_leisure_general_lighting,level_3_lighting_90_1_2019,57,default,118 -dining_cafeteria_fast_food_general_lighting,level_3_lighting_90_1_2019,58,default,237 -dining_area_for_family_dining_lighting,level_3_lighting_90_1_2019,60,default,237 -lobby_for_hotel_lighting,level_3_lighting_90_1_2019,73,default,178 -lobby_for_motion_picture_theater_lighting,level_3_lighting_90_1_2019,74,default,118 -lobby_for_performing_arts_theater_lighting,level_3_lighting_90_1_2019,75,default,296 -lounge_recreation_for_hospital_lighting,level_3_lighting_90_1_2019,78,default,296 -office-enclosed_general_lighting,level_3_lighting_90_1_2019,80,default,355 -office_open_plan_lighting,level_3_lighting_90_1_2019,81,default,414 -automotive_general_lighting,level_3_lighting_90_1_2019,94,default,355 -convention_center_exhibit_space_general_lighting,level_3_lighting_90_1_2019,95,default,431 -library_reading_area_lighting,level_3_lighting_90_1_2019,111,default,592 -library_stacks_lighting,level_3_lighting_90_1_2019,112,default,355 -manufacturing_facility_detailed_manufacturing_area_lighting,level_3_lighting_90_1_2019,113,default,592 -manufacturing_facility_equipment_room_lighting,level_3_lighting_90_1_2019,114,default,237 -manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting,level_3_lighting_90_1_2019,116,default,592 -manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting,level_3_lighting_90_1_2019,117,default,592 -museum_restoration_room_lighting,level_3_lighting_90_1_2019,119,default,592 -post_office_sorting_area_general_lighting,level_3_lighting_90_1_2019,121,default,474 -religious_buildings_fellowship_hall_lighting,level_3_lighting_90_1_2019,122,default,355 -religious_buildings_worship_pulpit_choir_lighting,level_3_lighting_90_1_2019,123,default,355 -retail_mall_concourse_lighting,level_3_lighting_90_1_2019,125,default,403 -transportation_facility_ticket_counter_lighting,level_3_lighting_90_1_2019,136,default,296 -warehouse_storage_area_medium_to_bulky_palletized_items_lighting,level_3_lighting_90_1_2019,137,default,355 -warehouse_storage_area_smaller_hand-carried_items_lighting,level_3_lighting_90_1_2019,138,default,237 +lighting_space_type_name,level_3_lighting_code_definition_table,level_3_lighting_code_definition_id,lighting_technology_name,lighting_space_type_target_illuminance_setpoint,annotation +airport_concourse_lighting,level_3_lighting_90_1_2004,122,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +atrium_lighting,level_3_lighting_90_1_2004,36,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +none_lighting,level_3_lighting_90_1_2004,126,default,0,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_lighting,level_3_lighting_90_1_2004,46,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +baggage_carousel_lighting,level_3_lighting_90_1_2004,121,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +banking_lighting,level_3_lighting_90_1_2004,77,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +classroom_lecture_training_lighting,level_3_lighting_90_1_2004,48,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +computer_room_lighting,level_3_lighting_90_1_2004,48,default,710,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +conference_meeting_multipurpose_lighting,level_3_lighting_90_1_2004,49,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +confinement_cells_lighting,level_3_lighting_90_1_2004,79,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +copy_print_lighting,level_3_lighting_90_1_2004,49,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +corridor_lighting,level_3_lighting_90_1_2004,52,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +courtroom_lighting,level_3_lighting_90_1_2004,80,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +datacenterhighite_lighting,level_3_lighting_90_1_2004,60,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +datacenterlowite_lighting,level_3_lighting_90_1_2004,60,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_lighting,level_3_lighting_90_1_2004,58,default,308,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dressing_room_lighting,level_3_lighting_90_1_2004,59,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +electrical_mechanical_lighting,level_3_lighting_90_1_2004,60,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +emergency_room_lighting,level_3_lighting_90_1_2004,87,default,888,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +emergency_vehicle_garage_lighting,level_3_lighting_90_1_2004,83,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +exam_treatment_lighting,level_3_lighting_90_1_2004,88,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +exercise_area_lighting,level_3_lighting_90_1_2004,85,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +exhibit_lighting,level_3_lighting_90_1_2004,108,default,431,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +guest_room_lighting,level_3_lighting_90_1_2004,99,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +imaging_lighting,level_3_lighting_90_1_2004,97,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +interior_parking_lighting,level_3_lighting_90_1_2004,110,default,54,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +judges_chambers_lighting,level_3_lighting_90_1_2004,81,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +food_preparation_lighting,level_3_lighting_90_1_2004,61,default,538,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +laboratory_lighting,level_3_lighting_90_1_2004,64,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +laundry_washing_lighting,level_3_lighting_90_1_2004,89,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +library_lighting,level_3_lighting_90_1_2004,13,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +living_quarters_lighting,level_3_lighting_90_1_2004,82,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +loading_dock_lighting,level_3_lighting_90_1_2004,30,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lobby_lighting,level_3_lighting_90_1_2004,68,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +locker_room_lighting,level_3_lighting_90_1_2004,59,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lounge_breakroom_lighting,level_3_lighting_90_1_2004,70,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_lighting,level_3_lighting_90_1_2004,14,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +medical_supply_lighting,level_3_lighting_90_1_2004,90,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +multifamily_lighting,level_3_lighting_90_1_2004,17,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +nursery_lighting,level_3_lighting_90_1_2004,92,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +nurses_station_lighting,level_3_lighting_90_1_2004,91,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +office_lighting,level_3_lighting_90_1_2004,19,default,414,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +office_enclosed_lighting,level_3_lighting_90_1_2004,71,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +operating_room_lighting,level_3_lighting_90_1_2004,93,default,1184,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +patient_room_lighting,level_3_lighting_90_1_2004,94,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +pharmacy_lighting,level_3_lighting_90_1_2004,95,default,888,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +physical_therapy_lighting,level_3_lighting_90_1_2004,96,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +playing_area_lighting,level_3_lighting_90_1_2004,86,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +post_office_lighting,level_3_lighting_90_1_2004,24,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +recovery_lighting,level_3_lighting_90_1_2004,98,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +recreation_common_living_lighting,level_3_lighting_90_1_2004,70,default,323,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +restroom_lighting,level_3_lighting_90_1_2004,73,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +retail_sales_lighting,level_3_lighting_90_1_2004,117,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +sleeping_quarters_lighting,level_3_lighting_90_1_2004,84,default,59,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +sports_arena_lighting,level_3_lighting_90_1_2004,28,default,1184,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +stairwell_lighting,level_3_lighting_90_1_2004,74,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +storage_lighting,level_3_lighting_90_1_2004,34,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +transportation_lighting,level_3_lighting_90_1_2004,30,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +vehicular_maintenance_lighting,level_3_lighting_90_1_2004,76,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +workshop_lighting,level_3_lighting_90_1_2004,32,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +worship_lighting,level_3_lighting_90_1_2004,25,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_automotive_facility_lighting,level_3_lighting_90_1_2004,1,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_convention_center_lighting,level_3_lighting_90_1_2004,2,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_courthouse_lighting,level_3_lighting_90_1_2004,3,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_dining_bar_lounge_leisure_lighting,level_3_lighting_90_1_2004,4,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_dining_cafeteria_fast_food_lighting,level_3_lighting_90_1_2004,5,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_dining_family_lighting,level_3_lighting_90_1_2004,6,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_dormitory_lighting,level_3_lighting_90_1_2004,7,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_exercise_center_lighting,level_3_lighting_90_1_2004,8,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_fire_station_lighting,level_3_lighting_90_1_2004,23,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_gymnasium_lighting,level_3_lighting_90_1_2004,9,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_health-care_clinic_lighting,level_3_lighting_90_1_2004,10,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_hospital_lighting,level_3_lighting_90_1_2004,11,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_hotel_motel_lighting,level_3_lighting_90_1_2004,12,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_motion_picture_theater_lighting,level_3_lighting_90_1_2004,16,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_museum_lighting,level_3_lighting_90_1_2004,18,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_parking_garage_lighting,level_3_lighting_90_1_2004,20,default,54,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_penitentiary_lighting,level_3_lighting_90_1_2004,21,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_performing_arts_theater_lighting,level_3_lighting_90_1_2004,22,default,426,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_police_station_lighting,level_3_lighting_90_1_2004,23,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_school_university_lighting,level_3_lighting_90_1_2004,27,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_town_hall_lighting,level_3_lighting_90_1_2004,29,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_retail_lighting,level_3_lighting_90_1_2004,26,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_warehouse_lighting,level_3_lighting_90_1_2004,31,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_gymnasium_lighting,level_3_lighting_90_1_2004,39,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_motion_picture_theater_lighting,level_3_lighting_90_1_2004,40,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_penitentiary_lighting,level_3_lighting_90_1_2004,41,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_performing_arts_theater_lighting,level_3_lighting_90_1_2004,42,default,426,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_religious_buildings_lighting,level_3_lighting_90_1_2004,43,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_sports_arena_lighting,level_3_lighting_90_1_2004,44,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +classroom_lecture_training_for_penitentiary_lighting,level_3_lighting_90_1_2004,47,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +corridor_transition_for_hospital_lighting,level_3_lighting_90_1_2004,50,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_area_for_penitentiary_lighting,level_3_lighting_90_1_2004,57,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_bar_lounge_leisure_general_lighting,level_3_lighting_90_1_2004,4,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_cafeteria_fast_food_general_lighting,level_3_lighting_90_1_2004,5,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_area_for_family_dining_lighting,level_3_lighting_90_1_2004,54,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lobby_for_hotel_lighting,level_3_lighting_90_1_2004,65,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lobby_for_motion_picture_theater_lighting,level_3_lighting_90_1_2004,66,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lobby_for_performing_arts_theater_lighting,level_3_lighting_90_1_2004,67,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lounge_recreation_for_hospital_lighting,level_3_lighting_90_1_2004,69,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +office-enclosed_general_lighting,level_3_lighting_90_1_2004,71,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +office_open_plan_lighting,level_3_lighting_90_1_2004,72,default,414,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +automotive_general_lighting,level_3_lighting_90_1_2004,76,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +convention_center_exhibit_space_general_lighting,level_3_lighting_90_1_2004,78,default,431,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +library_reading_area_lighting,level_3_lighting_90_1_2004,101,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +library_stacks_lighting,level_3_lighting_90_1_2004,102,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_facility_detailed_manufacturing_area_lighting,level_3_lighting_90_1_2004,104,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_facility_equipment_room_lighting,level_3_lighting_90_1_2004,105,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting,level_3_lighting_90_1_2004,106,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting,level_3_lighting_90_1_2004,107,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +museum_restoration_room_lighting,level_3_lighting_90_1_2004,109,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +post_office_sorting_area_general_lighting,level_3_lighting_90_1_2004,111,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +religious_buildings_fellowship_hall_lighting,level_3_lighting_90_1_2004,112,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +religious_buildings_worship_pulpit_choir_lighting,level_3_lighting_90_1_2004,113,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +retail_mall_concourse_lighting,level_3_lighting_90_1_2004,114,default,403,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +transportation_facility_ticket_counter_lighting,level_3_lighting_90_1_2004,123,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +warehouse_storage_area_medium_to_bulky_palletized_items_lighting,level_3_lighting_90_1_2004,125,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +warehouse_storage_area_smaller_hand-carried_items_lighting,level_3_lighting_90_1_2004,124,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +airport_concourse_lighting,level_3_lighting_90_1_2007,125,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +atrium_lighting,level_3_lighting_90_1_2007,36,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +none_lighting,level_3_lighting_90_1_2007,129,default,0,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_lighting,level_3_lighting_90_1_2007,46,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +baggage_carousel_lighting,level_3_lighting_90_1_2007,124,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +banking_lighting,level_3_lighting_90_1_2007,78,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +classroom_lecture_training_lighting,level_3_lighting_90_1_2007,48,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +computer_room_lighting,level_3_lighting_90_1_2007,48,default,710,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +conference_meeting_multipurpose_lighting,level_3_lighting_90_1_2007,49,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +confinement_cells_lighting,level_3_lighting_90_1_2007,80,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +copy_print_lighting,level_3_lighting_90_1_2007,49,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +corridor_lighting,level_3_lighting_90_1_2007,52,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +courtroom_lighting,level_3_lighting_90_1_2007,81,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +datacenterhighite_lighting,level_3_lighting_90_1_2007,60,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +datacenterlowite_lighting,level_3_lighting_90_1_2007,60,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_lighting,level_3_lighting_90_1_2007,58,default,308,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dressing_room_lighting,level_3_lighting_90_1_2007,59,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +electrical_mechanical_lighting,level_3_lighting_90_1_2007,60,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +emergency_room_lighting,level_3_lighting_90_1_2007,88,default,888,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +emergency_vehicle_garage_lighting,level_3_lighting_90_1_2007,84,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +exam_treatment_lighting,level_3_lighting_90_1_2007,89,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +exercise_area_lighting,level_3_lighting_90_1_2007,86,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +exhibit_lighting,level_3_lighting_90_1_2007,109,default,431,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +guest_room_lighting,level_3_lighting_90_1_2007,100,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +imaging_lighting,level_3_lighting_90_1_2007,98,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +interior_parking_lighting,level_3_lighting_90_1_2007,111,default,54,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +judges_chambers_lighting,level_3_lighting_90_1_2007,82,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +food_preparation_lighting,level_3_lighting_90_1_2007,61,default,538,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +laboratory_lighting,level_3_lighting_90_1_2007,64,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +laundry_washing_lighting,level_3_lighting_90_1_2007,90,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +library_lighting,level_3_lighting_90_1_2007,13,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +living_quarters_lighting,level_3_lighting_90_1_2007,83,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +loading_dock_lighting,level_3_lighting_90_1_2007,30,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lobby_lighting,level_3_lighting_90_1_2007,68,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +locker_room_lighting,level_3_lighting_90_1_2007,59,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lounge_breakroom_lighting,level_3_lighting_90_1_2007,70,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_lighting,level_3_lighting_90_1_2007,14,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +medical_supply_lighting,level_3_lighting_90_1_2007,91,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +multifamily_lighting,level_3_lighting_90_1_2007,17,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +nursery_lighting,level_3_lighting_90_1_2007,93,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +nurses_station_lighting,level_3_lighting_90_1_2007,92,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +office_lighting,level_3_lighting_90_1_2007,19,default,414,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +office_enclosed_lighting,level_3_lighting_90_1_2007,71,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +operating_room_lighting,level_3_lighting_90_1_2007,94,default,1184,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +patient_room_lighting,level_3_lighting_90_1_2007,95,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +pharmacy_lighting,level_3_lighting_90_1_2007,96,default,888,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +physical_therapy_lighting,level_3_lighting_90_1_2007,97,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +playing_area_lighting,level_3_lighting_90_1_2007,87,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +post_office_lighting,level_3_lighting_90_1_2007,24,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +recovery_lighting,level_3_lighting_90_1_2007,99,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +recreation_common_living_lighting,level_3_lighting_90_1_2007,70,default,323,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +restroom_lighting,level_3_lighting_90_1_2007,73,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +retail_sales_lighting,level_3_lighting_90_1_2007,120,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +sleeping_quarters_lighting,level_3_lighting_90_1_2007,85,default,59,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +sports_arena_lighting,level_3_lighting_90_1_2007,28,default,1184,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +stairwell_lighting,level_3_lighting_90_1_2007,75,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +storage_lighting,level_3_lighting_90_1_2007,34,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +transportation_lighting,level_3_lighting_90_1_2007,30,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +vehicular_maintenance_lighting,level_3_lighting_90_1_2007,77,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +workshop_lighting,level_3_lighting_90_1_2007,32,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +worship_lighting,level_3_lighting_90_1_2007,25,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_automotive_facility_lighting,level_3_lighting_90_1_2007,1,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_convention_center_lighting,level_3_lighting_90_1_2007,2,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_courthouse_lighting,level_3_lighting_90_1_2007,3,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_dining_bar_lounge_leisure_lighting,level_3_lighting_90_1_2007,4,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_dining_cafeteria_fast_food_lighting,level_3_lighting_90_1_2007,5,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_dining_family_lighting,level_3_lighting_90_1_2007,6,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_dormitory_lighting,level_3_lighting_90_1_2007,7,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_exercise_center_lighting,level_3_lighting_90_1_2007,8,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_fire_station_lighting,level_3_lighting_90_1_2007,23,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_gymnasium_lighting,level_3_lighting_90_1_2007,9,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_health-care_clinic_lighting,level_3_lighting_90_1_2007,10,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_hospital_lighting,level_3_lighting_90_1_2007,11,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_hotel_motel_lighting,level_3_lighting_90_1_2007,12,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_motion_picture_theater_lighting,level_3_lighting_90_1_2007,16,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_museum_lighting,level_3_lighting_90_1_2007,18,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_parking_garage_lighting,level_3_lighting_90_1_2007,20,default,54,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_penitentiary_lighting,level_3_lighting_90_1_2007,21,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_performing_arts_theater_lighting,level_3_lighting_90_1_2007,22,default,426,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_police_station_lighting,level_3_lighting_90_1_2007,23,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_school_university_lighting,level_3_lighting_90_1_2007,27,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_town_hall_lighting,level_3_lighting_90_1_2007,29,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_retail_lighting,level_3_lighting_90_1_2007,26,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_warehouse_lighting,level_3_lighting_90_1_2007,31,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_gymnasium_lighting,level_3_lighting_90_1_2007,39,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_motion_picture_theater_lighting,level_3_lighting_90_1_2007,40,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_penitentiary_lighting,level_3_lighting_90_1_2007,41,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_performing_arts_theater_lighting,level_3_lighting_90_1_2007,42,default,426,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_religious_buildings_lighting,level_3_lighting_90_1_2007,43,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_sports_arena_lighting,level_3_lighting_90_1_2007,44,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +classroom_lecture_training_for_penitentiary_lighting,level_3_lighting_90_1_2007,47,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +corridor_transition_for_hospital_lighting,level_3_lighting_90_1_2007,50,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_area_for_penitentiary_lighting,level_3_lighting_90_1_2007,57,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_bar_lounge_leisure_general_lighting,level_3_lighting_90_1_2007,4,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_cafeteria_fast_food_general_lighting,level_3_lighting_90_1_2007,5,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_area_for_family_dining_lighting,level_3_lighting_90_1_2007,54,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lobby_for_hotel_lighting,level_3_lighting_90_1_2007,65,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lobby_for_motion_picture_theater_lighting,level_3_lighting_90_1_2007,66,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lobby_for_performing_arts_theater_lighting,level_3_lighting_90_1_2007,67,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lounge_recreation_for_hospital_lighting,level_3_lighting_90_1_2007,69,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +office-enclosed_general_lighting,level_3_lighting_90_1_2007,71,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +office_open_plan_lighting,level_3_lighting_90_1_2007,72,default,414,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +automotive_general_lighting,level_3_lighting_90_1_2007,77,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +convention_center_exhibit_space_general_lighting,level_3_lighting_90_1_2007,79,default,431,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +library_reading_area_lighting,level_3_lighting_90_1_2007,102,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +library_stacks_lighting,level_3_lighting_90_1_2007,103,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_facility_detailed_manufacturing_area_lighting,level_3_lighting_90_1_2007,105,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_facility_equipment_room_lighting,level_3_lighting_90_1_2007,106,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting,level_3_lighting_90_1_2007,107,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting,level_3_lighting_90_1_2007,108,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +museum_restoration_room_lighting,level_3_lighting_90_1_2007,110,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +post_office_sorting_area_general_lighting,level_3_lighting_90_1_2007,112,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +religious_buildings_fellowship_hall_lighting,level_3_lighting_90_1_2007,113,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +religious_buildings_worship_pulpit_choir_lighting,level_3_lighting_90_1_2007,114,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +retail_mall_concourse_lighting,level_3_lighting_90_1_2007,115,default,403,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +transportation_facility_ticket_counter_lighting,level_3_lighting_90_1_2007,126,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +warehouse_storage_area_medium_to_bulky_palletized_items_lighting,level_3_lighting_90_1_2007,128,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +warehouse_storage_area_smaller_hand-carried_items_lighting,level_3_lighting_90_1_2007,127,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +airport_concourse_lighting,level_3_lighting_90_1_2010,128,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +atrium_lighting,level_3_lighting_90_1_2010,34,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +none_lighting,level_3_lighting_90_1_2010,133,default,0,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_lighting,level_3_lighting_90_1_2010,36,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +baggage_carousel_lighting,level_3_lighting_90_1_2010,127,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +banking_lighting,level_3_lighting_90_1_2010,64,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +classroom_lecture_training_lighting,level_3_lighting_90_1_2010,39,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +computer_room_lighting,level_3_lighting_90_1_2010,39,default,710,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +conference_meeting_multipurpose_lighting,level_3_lighting_90_1_2010,40,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +confinement_cells_lighting,level_3_lighting_90_1_2010,67,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +copy_print_lighting,level_3_lighting_90_1_2010,40,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +corridor_lighting,level_3_lighting_90_1_2010,41,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +courtroom_lighting,level_3_lighting_90_1_2010,68,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +datacenterhighite_lighting,level_3_lighting_90_1_2010,46,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +datacenterlowite_lighting,level_3_lighting_90_1_2010,46,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_lighting,level_3_lighting_90_1_2010,44,default,308,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dressing_room_lighting,level_3_lighting_90_1_2010,113,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +electrical_mechanical_lighting,level_3_lighting_90_1_2010,46,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +emergency_room_lighting,level_3_lighting_90_1_2010,80,default,888,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +emergency_vehicle_garage_lighting,level_3_lighting_90_1_2010,74,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +exam_treatment_lighting,level_3_lighting_90_1_2010,81,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +exercise_area_lighting,level_3_lighting_90_1_2010,76,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +exhibit_lighting,level_3_lighting_90_1_2010,107,default,431,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +guest_room_lighting,level_3_lighting_90_1_2010,96,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +imaging_lighting,level_3_lighting_90_1_2010,91,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +interior_parking_lighting,level_3_lighting_90_1_2010,109,default,54,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +judges_chambers_lighting,level_3_lighting_90_1_2010,69,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +food_preparation_lighting,level_3_lighting_90_1_2010,47,default,538,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +laboratory_lighting,level_3_lighting_90_1_2010,49,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +laundry_washing_lighting,level_3_lighting_90_1_2010,82,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +library_lighting,level_3_lighting_90_1_2010,14,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +living_quarters_lighting,level_3_lighting_90_1_2010,73,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +loading_dock_lighting,level_3_lighting_90_1_2010,31,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lobby_lighting,level_3_lighting_90_1_2010,53,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +locker_room_lighting,level_3_lighting_90_1_2010,54,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lounge_breakroom_lighting,level_3_lighting_90_1_2010,55,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_lighting,level_3_lighting_90_1_2010,15,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +medical_supply_lighting,level_3_lighting_90_1_2010,84,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +multifamily_lighting,level_3_lighting_90_1_2010,18,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +nursery_lighting,level_3_lighting_90_1_2010,85,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +nurses_station_lighting,level_3_lighting_90_1_2010,86,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +office_lighting,level_3_lighting_90_1_2010,20,default,414,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +office_enclosed_lighting,level_3_lighting_90_1_2010,56,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +operating_room_lighting,level_3_lighting_90_1_2010,87,default,1184,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +patient_room_lighting,level_3_lighting_90_1_2010,88,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +pharmacy_lighting,level_3_lighting_90_1_2010,89,default,888,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +physical_therapy_lighting,level_3_lighting_90_1_2010,90,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +playing_area_lighting,level_3_lighting_90_1_2010,78,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +post_office_lighting,level_3_lighting_90_1_2010,25,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +recovery_lighting,level_3_lighting_90_1_2010,92,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +recreation_common_living_lighting,level_3_lighting_90_1_2010,55,default,323,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +restroom_lighting,level_3_lighting_90_1_2010,58,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +retail_sales_lighting,level_3_lighting_90_1_2010,119,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +sleeping_quarters_lighting,level_3_lighting_90_1_2010,75,default,59,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +sports_arena_lighting,level_3_lighting_90_1_2010,29,default,1184,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +stairwell_lighting,level_3_lighting_90_1_2010,60,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +storage_lighting,level_3_lighting_90_1_2010,61,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +transportation_lighting,level_3_lighting_90_1_2010,31,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +vehicular_maintenance_lighting,level_3_lighting_90_1_2010,63,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +workshop_lighting,level_3_lighting_90_1_2010,33,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +worship_lighting,level_3_lighting_90_1_2010,26,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_automotive_facility_lighting,level_3_lighting_90_1_2010,1,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_convention_center_lighting,level_3_lighting_90_1_2010,2,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_courthouse_lighting,level_3_lighting_90_1_2010,3,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_dining_bar_lounge_leisure_lighting,level_3_lighting_90_1_2010,4,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_dining_cafeteria_fast_food_lighting,level_3_lighting_90_1_2010,5,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_dining_family_lighting,level_3_lighting_90_1_2010,6,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_dormitory_lighting,level_3_lighting_90_1_2010,7,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_exercise_center_lighting,level_3_lighting_90_1_2010,8,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_fire_station_lighting,level_3_lighting_90_1_2010,9,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_gymnasium_lighting,level_3_lighting_90_1_2010,10,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_health-care_clinic_lighting,level_3_lighting_90_1_2010,11,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_hospital_lighting,level_3_lighting_90_1_2010,12,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_hotel_motel_lighting,level_3_lighting_90_1_2010,13,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_motion_picture_theater_lighting,level_3_lighting_90_1_2010,17,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_museum_lighting,level_3_lighting_90_1_2010,19,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_parking_garage_lighting,level_3_lighting_90_1_2010,21,default,54,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_penitentiary_lighting,level_3_lighting_90_1_2010,22,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_performing_arts_theater_lighting,level_3_lighting_90_1_2010,23,default,426,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_police_station_lighting,level_3_lighting_90_1_2010,24,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_school_university_lighting,level_3_lighting_90_1_2010,28,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_town_hall_lighting,level_3_lighting_90_1_2010,30,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_retail_lighting,level_3_lighting_90_1_2010,27,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_warehouse_lighting,level_3_lighting_90_1_2010,32,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_gymnasium_lighting,level_3_lighting_90_1_2010,77,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_motion_picture_theater_lighting,level_3_lighting_90_1_2010,37,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_penitentiary_lighting,level_3_lighting_90_1_2010,70,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_performing_arts_theater_lighting,level_3_lighting_90_1_2010,38,default,426,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_religious_buildings_lighting,level_3_lighting_90_1_2010,110,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_sports_arena_lighting,level_3_lighting_90_1_2010,120,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +classroom_lecture_training_for_penitentiary_lighting,level_3_lighting_90_1_2010,71,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +corridor_transition_for_hospital_lighting,level_3_lighting_90_1_2010,79,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_area_for_penitentiary_lighting,level_3_lighting_90_1_2010,72,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_bar_lounge_leisure_general_lighting,level_3_lighting_90_1_2010,4,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_cafeteria_fast_food_general_lighting,level_3_lighting_90_1_2010,5,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_area_for_family_dining_lighting,level_3_lighting_90_1_2010,43,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lobby_for_hotel_lighting,level_3_lighting_90_1_2010,97,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lobby_for_motion_picture_theater_lighting,level_3_lighting_90_1_2010,51,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lobby_for_performing_arts_theater_lighting,level_3_lighting_90_1_2010,52,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lounge_recreation_for_hospital_lighting,level_3_lighting_90_1_2010,83,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +office-enclosed_general_lighting,level_3_lighting_90_1_2010,56,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +office_open_plan_lighting,level_3_lighting_90_1_2010,57,default,414,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +automotive_general_lighting,level_3_lighting_90_1_2010,63,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +convention_center_exhibit_space_general_lighting,level_3_lighting_90_1_2010,66,default,431,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +library_reading_area_lighting,level_3_lighting_90_1_2010,99,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +library_stacks_lighting,level_3_lighting_90_1_2010,100,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_facility_detailed_manufacturing_area_lighting,level_3_lighting_90_1_2010,102,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_facility_equipment_room_lighting,level_3_lighting_90_1_2010,103,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting,level_3_lighting_90_1_2010,105,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting,level_3_lighting_90_1_2010,106,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +museum_restoration_room_lighting,level_3_lighting_90_1_2010,108,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +post_office_sorting_area_general_lighting,level_3_lighting_90_1_2010,126,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +religious_buildings_fellowship_hall_lighting,level_3_lighting_90_1_2010,111,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +religious_buildings_worship_pulpit_choir_lighting,level_3_lighting_90_1_2010,112,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +retail_mall_concourse_lighting,level_3_lighting_90_1_2010,114,default,403,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +transportation_facility_ticket_counter_lighting,level_3_lighting_90_1_2010,130,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +warehouse_storage_area_medium_to_bulky_palletized_items_lighting,level_3_lighting_90_1_2010,132,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +warehouse_storage_area_smaller_hand-carried_items_lighting,level_3_lighting_90_1_2010,131,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +airport_concourse_lighting,level_3_lighting_90_1_2013,140,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +atrium_lighting,level_3_lighting_90_1_2013,33,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +none_lighting,level_3_lighting_90_1_2013,143,default,0,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_lighting,level_3_lighting_90_1_2013,36,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +baggage_carousel_lighting,level_3_lighting_90_1_2013,139,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +banking_lighting,level_3_lighting_90_1_2013,45,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +classroom_lecture_training_lighting,level_3_lighting_90_1_2013,47,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +computer_room_lighting,level_3_lighting_90_1_2013,49,default,710,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +conference_meeting_multipurpose_lighting,level_3_lighting_90_1_2013,50,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +confinement_cells_lighting,level_3_lighting_90_1_2013,51,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +copy_print_lighting,level_3_lighting_90_1_2013,52,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +corridor_lighting,level_3_lighting_90_1_2013,53,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +courtroom_lighting,level_3_lighting_90_1_2013,57,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +datacenterhighite_lighting,level_3_lighting_90_1_2013,64,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +datacenterlowite_lighting,level_3_lighting_90_1_2013,64,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_lighting,level_3_lighting_90_1_2013,58,default,308,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dressing_room_lighting,level_3_lighting_90_1_2013,128,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +electrical_mechanical_lighting,level_3_lighting_90_1_2013,64,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +emergency_room_lighting,level_3_lighting_90_1_2013,112,default,888,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +emergency_vehicle_garage_lighting,level_3_lighting_90_1_2013,65,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +exam_treatment_lighting,level_3_lighting_90_1_2013,112,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +exercise_area_lighting,level_3_lighting_90_1_2013,105,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +exhibit_lighting,level_3_lighting_90_1_2013,122,default,431,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +guest_room_lighting,level_3_lighting_90_1_2013,67,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +imaging_lighting,level_3_lighting_90_1_2013,113,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +interior_parking_lighting,level_3_lighting_90_1_2013,84,default,54,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +judges_chambers_lighting,level_3_lighting_90_1_2013,57,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +food_preparation_lighting,level_3_lighting_90_1_2013,66,default,538,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +laboratory_lighting,level_3_lighting_90_1_2013,68,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +laundry_washing_lighting,level_3_lighting_90_1_2013,70,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +library_lighting,level_3_lighting_90_1_2013,14,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +living_quarters_lighting,level_3_lighting_90_1_2013,99,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +loading_dock_lighting,level_3_lighting_90_1_2013,71,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lobby_lighting,level_3_lighting_90_1_2013,72,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +locker_room_lighting,level_3_lighting_90_1_2013,78,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lounge_breakroom_lighting,level_3_lighting_90_1_2013,46,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_lighting,level_3_lighting_90_1_2013,15,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +medical_supply_lighting,level_3_lighting_90_1_2013,106,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +multifamily_lighting,level_3_lighting_90_1_2013,17,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +nursery_lighting,level_3_lighting_90_1_2013,108,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +nurses_station_lighting,level_3_lighting_90_1_2013,107,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +office_lighting,level_3_lighting_90_1_2013,19,default,414,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +office_enclosed_lighting,level_3_lighting_90_1_2013,81,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +operating_room_lighting,level_3_lighting_90_1_2013,114,default,1184,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +patient_room_lighting,level_3_lighting_90_1_2013,109,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +pharmacy_lighting,level_3_lighting_90_1_2013,106,default,888,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +physical_therapy_lighting,level_3_lighting_90_1_2013,110,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +playing_area_lighting,level_3_lighting_90_1_2013,104,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +post_office_lighting,level_3_lighting_90_1_2013,24,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +recovery_lighting,level_3_lighting_90_1_2013,111,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +recreation_common_living_lighting,level_3_lighting_90_1_2013,79,default,323,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +restroom_lighting,level_3_lighting_90_1_2013,86,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +retail_sales_lighting,level_3_lighting_90_1_2013,88,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +sleeping_quarters_lighting,level_3_lighting_90_1_2013,103,default,59,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +sports_arena_lighting,level_3_lighting_90_1_2013,28,default,1184,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +stairwell_lighting,level_3_lighting_90_1_2013,91,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +storage_lighting,level_3_lighting_90_1_2013,94,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +transportation_lighting,level_3_lighting_90_1_2013,30,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +vehicular_maintenance_lighting,level_3_lighting_90_1_2013,95,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +workshop_lighting,level_3_lighting_90_1_2013,32,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +worship_lighting,level_3_lighting_90_1_2013,25,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_automotive_facility_lighting,level_3_lighting_90_1_2013,1,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_convention_center_lighting,level_3_lighting_90_1_2013,2,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_courthouse_lighting,level_3_lighting_90_1_2013,3,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_dining_bar_lounge_leisure_lighting,level_3_lighting_90_1_2013,4,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_dining_cafeteria_fast_food_lighting,level_3_lighting_90_1_2013,5,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_dining_family_lighting,level_3_lighting_90_1_2013,6,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_dormitory_lighting,level_3_lighting_90_1_2013,7,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_exercise_center_lighting,level_3_lighting_90_1_2013,8,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_fire_station_lighting,level_3_lighting_90_1_2013,9,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_gymnasium_lighting,level_3_lighting_90_1_2013,10,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_health-care_clinic_lighting,level_3_lighting_90_1_2013,11,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_hospital_lighting,level_3_lighting_90_1_2013,12,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_hotel_motel_lighting,level_3_lighting_90_1_2013,13,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_motion_picture_theater_lighting,level_3_lighting_90_1_2013,16,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_museum_lighting,level_3_lighting_90_1_2013,18,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_parking_garage_lighting,level_3_lighting_90_1_2013,20,default,54,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_penitentiary_lighting,level_3_lighting_90_1_2013,21,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_performing_arts_theater_lighting,level_3_lighting_90_1_2013,22,default,426,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_police_station_lighting,level_3_lighting_90_1_2013,23,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_school_university_lighting,level_3_lighting_90_1_2013,27,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_town_hall_lighting,level_3_lighting_90_1_2013,29,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_retail_lighting,level_3_lighting_90_1_2013,26,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_warehouse_lighting,level_3_lighting_90_1_2013,31,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_gymnasium_lighting,level_3_lighting_90_1_2013,38,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_motion_picture_theater_lighting,level_3_lighting_90_1_2013,39,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_penitentiary_lighting,level_3_lighting_90_1_2013,40,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_performing_arts_theater_lighting,level_3_lighting_90_1_2013,41,default,426,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_religious_buildings_lighting,level_3_lighting_90_1_2013,42,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_sports_arena_lighting,level_3_lighting_90_1_2013,43,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +classroom_lecture_training_for_penitentiary_lighting,level_3_lighting_90_1_2013,48,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +corridor_transition_for_hospital_lighting,level_3_lighting_90_1_2013,55,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_area_for_penitentiary_lighting,level_3_lighting_90_1_2013,60,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_bar_lounge_leisure_general_lighting,level_3_lighting_90_1_2013,4,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_cafeteria_fast_food_general_lighting,level_3_lighting_90_1_2013,5,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_area_for_family_dining_lighting,level_3_lighting_90_1_2013,63,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lobby_for_hotel_lighting,level_3_lighting_90_1_2013,75,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lobby_for_motion_picture_theater_lighting,level_3_lighting_90_1_2013,76,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lobby_for_performing_arts_theater_lighting,level_3_lighting_90_1_2013,77,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lounge_recreation_for_hospital_lighting,level_3_lighting_90_1_2013,80,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +office-enclosed_general_lighting,level_3_lighting_90_1_2013,81,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +office_open_plan_lighting,level_3_lighting_90_1_2013,83,default,414,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +automotive_general_lighting,level_3_lighting_90_1_2013,97,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +convention_center_exhibit_space_general_lighting,level_3_lighting_90_1_2013,98,default,431,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +library_reading_area_lighting,level_3_lighting_90_1_2013,115,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +library_stacks_lighting,level_3_lighting_90_1_2013,116,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_facility_detailed_manufacturing_area_lighting,level_3_lighting_90_1_2013,117,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_facility_equipment_room_lighting,level_3_lighting_90_1_2013,120,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting,level_3_lighting_90_1_2013,118,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting,level_3_lighting_90_1_2013,119,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +museum_restoration_room_lighting,level_3_lighting_90_1_2013,123,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +post_office_sorting_area_general_lighting,level_3_lighting_90_1_2013,125,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +religious_buildings_fellowship_hall_lighting,level_3_lighting_90_1_2013,127,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +religious_buildings_worship_pulpit_choir_lighting,level_3_lighting_90_1_2013,126,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +retail_mall_concourse_lighting,level_3_lighting_90_1_2013,129,default,403,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +transportation_facility_ticket_counter_lighting,level_3_lighting_90_1_2013,138,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +warehouse_storage_area_medium_to_bulky_palletized_items_lighting,level_3_lighting_90_1_2013,141,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +warehouse_storage_area_smaller_hand-carried_items_lighting,level_3_lighting_90_1_2013,142,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +airport_concourse_lighting,level_3_lighting_90_1_2016,137,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +atrium_lighting,level_3_lighting_90_1_2016,33,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +none_lighting,level_3_lighting_90_1_2016,142,default,0,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_lighting,level_3_lighting_90_1_2016,36,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +baggage_carousel_lighting,level_3_lighting_90_1_2016,138,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +banking_lighting,level_3_lighting_90_1_2016,45,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +classroom_lecture_training_lighting,level_3_lighting_90_1_2016,47,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +computer_room_lighting,level_3_lighting_90_1_2016,49,default,710,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +conference_meeting_multipurpose_lighting,level_3_lighting_90_1_2016,50,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +confinement_cells_lighting,level_3_lighting_90_1_2016,51,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +copy_print_lighting,level_3_lighting_90_1_2016,52,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +corridor_lighting,level_3_lighting_90_1_2016,53,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +courtroom_lighting,level_3_lighting_90_1_2016,57,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +datacenterhighite_lighting,level_3_lighting_90_1_2016,64,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +datacenterlowite_lighting,level_3_lighting_90_1_2016,64,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_lighting,level_3_lighting_90_1_2016,58,default,308,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dressing_room_lighting,level_3_lighting_90_1_2016,127,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +electrical_mechanical_lighting,level_3_lighting_90_1_2016,64,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +emergency_room_lighting,level_3_lighting_90_1_2016,105,default,888,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +emergency_vehicle_garage_lighting,level_3_lighting_90_1_2016,65,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +exam_treatment_lighting,level_3_lighting_90_1_2016,105,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +exercise_area_lighting,level_3_lighting_90_1_2016,103,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +exhibit_lighting,level_3_lighting_90_1_2016,121,default,431,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +guest_room_lighting,level_3_lighting_90_1_2016,67,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +imaging_lighting,level_3_lighting_90_1_2016,106,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +interior_parking_lighting,level_3_lighting_90_1_2016,84,default,54,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +judges_chambers_lighting,level_3_lighting_90_1_2016,57,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +food_preparation_lighting,level_3_lighting_90_1_2016,66,default,538,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +laboratory_lighting,level_3_lighting_90_1_2016,68,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +laundry_washing_lighting,level_3_lighting_90_1_2016,70,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +library_lighting,level_3_lighting_90_1_2016,14,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +living_quarters_lighting,level_3_lighting_90_1_2016,99,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +loading_dock_lighting,level_3_lighting_90_1_2016,71,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lobby_lighting,level_3_lighting_90_1_2016,72,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +locker_room_lighting,level_3_lighting_90_1_2016,78,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lounge_breakroom_lighting,level_3_lighting_90_1_2016,46,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_lighting,level_3_lighting_90_1_2016,15,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +medical_supply_lighting,level_3_lighting_90_1_2016,107,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +multifamily_lighting,level_3_lighting_90_1_2016,17,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +nursery_lighting,level_3_lighting_90_1_2016,109,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +nurses_station_lighting,level_3_lighting_90_1_2016,108,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +office_lighting,level_3_lighting_90_1_2016,19,default,414,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +office_enclosed_lighting,level_3_lighting_90_1_2016,81,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +operating_room_lighting,level_3_lighting_90_1_2016,110,default,1184,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +patient_room_lighting,level_3_lighting_90_1_2016,111,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +pharmacy_lighting,level_3_lighting_90_1_2016,107,default,888,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +physical_therapy_lighting,level_3_lighting_90_1_2016,112,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +playing_area_lighting,level_3_lighting_90_1_2016,104,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +post_office_lighting,level_3_lighting_90_1_2016,24,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +recovery_lighting,level_3_lighting_90_1_2016,113,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +recreation_common_living_lighting,level_3_lighting_90_1_2016,79,default,323,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +restroom_lighting,level_3_lighting_90_1_2016,86,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +retail_sales_lighting,level_3_lighting_90_1_2016,88,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +sleeping_quarters_lighting,level_3_lighting_90_1_2016,102,default,59,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +sports_arena_lighting,level_3_lighting_90_1_2016,28,default,1184,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +stairwell_lighting,level_3_lighting_90_1_2016,91,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +storage_lighting,level_3_lighting_90_1_2016,94,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +transportation_lighting,level_3_lighting_90_1_2016,30,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +vehicular_maintenance_lighting,level_3_lighting_90_1_2016,95,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +workshop_lighting,level_3_lighting_90_1_2016,32,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +worship_lighting,level_3_lighting_90_1_2016,25,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_automotive_facility_lighting,level_3_lighting_90_1_2016,1,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_convention_center_lighting,level_3_lighting_90_1_2016,2,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_courthouse_lighting,level_3_lighting_90_1_2016,3,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_dining_bar_lounge_leisure_lighting,level_3_lighting_90_1_2016,4,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_dining_cafeteria_fast_food_lighting,level_3_lighting_90_1_2016,5,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_dining_family_lighting,level_3_lighting_90_1_2016,6,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_dormitory_lighting,level_3_lighting_90_1_2016,7,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_exercise_center_lighting,level_3_lighting_90_1_2016,8,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_fire_station_lighting,level_3_lighting_90_1_2016,9,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_gymnasium_lighting,level_3_lighting_90_1_2016,10,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_health-care_clinic_lighting,level_3_lighting_90_1_2016,11,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_hospital_lighting,level_3_lighting_90_1_2016,12,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_hotel_motel_lighting,level_3_lighting_90_1_2016,13,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_motion_picture_theater_lighting,level_3_lighting_90_1_2016,16,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_museum_lighting,level_3_lighting_90_1_2016,18,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_parking_garage_lighting,level_3_lighting_90_1_2016,20,default,54,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_penitentiary_lighting,level_3_lighting_90_1_2016,21,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_performing_arts_theater_lighting,level_3_lighting_90_1_2016,22,default,426,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_police_station_lighting,level_3_lighting_90_1_2016,23,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_school_university_lighting,level_3_lighting_90_1_2016,27,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_town_hall_lighting,level_3_lighting_90_1_2016,29,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_retail_lighting,level_3_lighting_90_1_2016,26,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_warehouse_lighting,level_3_lighting_90_1_2016,31,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_gymnasium_lighting,level_3_lighting_90_1_2016,39,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_motion_picture_theater_lighting,level_3_lighting_90_1_2016,40,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_penitentiary_lighting,level_3_lighting_90_1_2016,41,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_performing_arts_theater_lighting,level_3_lighting_90_1_2016,42,default,426,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_religious_buildings_lighting,level_3_lighting_90_1_2016,43,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_sports_arena_lighting,level_3_lighting_90_1_2016,44,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +classroom_lecture_training_for_penitentiary_lighting,level_3_lighting_90_1_2016,48,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +corridor_transition_for_hospital_lighting,level_3_lighting_90_1_2016,55,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_area_for_penitentiary_lighting,level_3_lighting_90_1_2016,61,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_bar_lounge_leisure_general_lighting,level_3_lighting_90_1_2016,4,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_cafeteria_fast_food_general_lighting,level_3_lighting_90_1_2016,5,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_area_for_family_dining_lighting,level_3_lighting_90_1_2016,62,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lobby_for_hotel_lighting,level_3_lighting_90_1_2016,75,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lobby_for_motion_picture_theater_lighting,level_3_lighting_90_1_2016,76,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lobby_for_performing_arts_theater_lighting,level_3_lighting_90_1_2016,77,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lounge_recreation_for_hospital_lighting,level_3_lighting_90_1_2016,80,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +office-enclosed_general_lighting,level_3_lighting_90_1_2016,81,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +office_open_plan_lighting,level_3_lighting_90_1_2016,83,default,414,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +automotive_general_lighting,level_3_lighting_90_1_2016,97,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +convention_center_exhibit_space_general_lighting,level_3_lighting_90_1_2016,98,default,431,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +library_reading_area_lighting,level_3_lighting_90_1_2016,114,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +library_stacks_lighting,level_3_lighting_90_1_2016,115,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_facility_detailed_manufacturing_area_lighting,level_3_lighting_90_1_2016,116,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_facility_equipment_room_lighting,level_3_lighting_90_1_2016,117,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting,level_3_lighting_90_1_2016,119,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting,level_3_lighting_90_1_2016,120,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +museum_restoration_room_lighting,level_3_lighting_90_1_2016,122,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +post_office_sorting_area_general_lighting,level_3_lighting_90_1_2016,124,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +religious_buildings_fellowship_hall_lighting,level_3_lighting_90_1_2016,125,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +religious_buildings_worship_pulpit_choir_lighting,level_3_lighting_90_1_2016,126,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +retail_mall_concourse_lighting,level_3_lighting_90_1_2016,128,default,403,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +transportation_facility_ticket_counter_lighting,level_3_lighting_90_1_2016,139,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +warehouse_storage_area_medium_to_bulky_palletized_items_lighting,level_3_lighting_90_1_2016,140,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +warehouse_storage_area_smaller_hand-carried_items_lighting,level_3_lighting_90_1_2016,141,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +airport_concourse_lighting,level_3_lighting_90_1_2019,134,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +atrium_lighting,level_3_lighting_90_1_2019,33,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +none_lighting,level_3_lighting_90_1_2019,139,default,0,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_lighting,level_3_lighting_90_1_2019,36,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +baggage_carousel_lighting,level_3_lighting_90_1_2019,135,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +banking_lighting,level_3_lighting_90_1_2019,44,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +classroom_lecture_training_lighting,level_3_lighting_90_1_2019,46,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +computer_room_lighting,level_3_lighting_90_1_2019,48,default,710,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +conference_meeting_multipurpose_lighting,level_3_lighting_90_1_2019,49,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +confinement_cells_lighting,level_3_lighting_90_1_2019,50,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +copy_print_lighting,level_3_lighting_90_1_2019,51,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +corridor_lighting,level_3_lighting_90_1_2019,52,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +courtroom_lighting,level_3_lighting_90_1_2019,55,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +datacenterhighite_lighting,level_3_lighting_90_1_2019,62,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +datacenterlowite_lighting,level_3_lighting_90_1_2019,62,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_lighting,level_3_lighting_90_1_2019,56,default,308,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dressing_room_lighting,level_3_lighting_90_1_2019,124,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +electrical_mechanical_lighting,level_3_lighting_90_1_2019,62,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +emergency_room_lighting,level_3_lighting_90_1_2019,102,default,888,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +emergency_vehicle_garage_lighting,level_3_lighting_90_1_2019,63,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +exam_treatment_lighting,level_3_lighting_90_1_2019,102,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +exercise_area_lighting,level_3_lighting_90_1_2019,100,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +exhibit_lighting,level_3_lighting_90_1_2019,118,default,431,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +guest_room_lighting,level_3_lighting_90_1_2019,65,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +imaging_lighting,level_3_lighting_90_1_2019,103,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +interior_parking_lighting,level_3_lighting_90_1_2019,82,default,54,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +judges_chambers_lighting,level_3_lighting_90_1_2019,55,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +food_preparation_lighting,level_3_lighting_90_1_2019,64,default,538,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +laboratory_lighting,level_3_lighting_90_1_2019,66,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +laundry_washing_lighting,level_3_lighting_90_1_2019,68,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +library_lighting,level_3_lighting_90_1_2019,14,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +living_quarters_lighting,level_3_lighting_90_1_2019,96,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +loading_dock_lighting,level_3_lighting_90_1_2019,69,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lobby_lighting,level_3_lighting_90_1_2019,70,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +locker_room_lighting,level_3_lighting_90_1_2019,76,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lounge_breakroom_lighting,level_3_lighting_90_1_2019,45,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_lighting,level_3_lighting_90_1_2019,15,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +medical_supply_lighting,level_3_lighting_90_1_2019,104,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +multifamily_lighting,level_3_lighting_90_1_2019,17,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +nursery_lighting,level_3_lighting_90_1_2019,105,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +nurses_station_lighting,level_3_lighting_90_1_2019,106,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +office_lighting,level_3_lighting_90_1_2019,19,default,414,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +office_enclosed_lighting,level_3_lighting_90_1_2019,79,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +operating_room_lighting,level_3_lighting_90_1_2019,107,default,1184,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +patient_room_lighting,level_3_lighting_90_1_2019,108,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +pharmacy_lighting,level_3_lighting_90_1_2019,104,default,888,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +physical_therapy_lighting,level_3_lighting_90_1_2019,109,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +playing_area_lighting,level_3_lighting_90_1_2019,101,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +post_office_lighting,level_3_lighting_90_1_2019,24,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +recovery_lighting,level_3_lighting_90_1_2019,110,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +recreation_common_living_lighting,level_3_lighting_90_1_2019,77,default,323,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +restroom_lighting,level_3_lighting_90_1_2019,84,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +retail_sales_lighting,level_3_lighting_90_1_2019,86,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +sleeping_quarters_lighting,level_3_lighting_90_1_2019,99,default,59,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +sports_arena_lighting,level_3_lighting_90_1_2019,28,default,1184,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +stairwell_lighting,level_3_lighting_90_1_2019,89,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +storage_lighting,level_3_lighting_90_1_2019,91,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +transportation_lighting,level_3_lighting_90_1_2019,30,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +vehicular_maintenance_lighting,level_3_lighting_90_1_2019,92,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +workshop_lighting,level_3_lighting_90_1_2019,32,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +worship_lighting,level_3_lighting_90_1_2019,25,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_automotive_facility_lighting,level_3_lighting_90_1_2019,1,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_convention_center_lighting,level_3_lighting_90_1_2019,2,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_courthouse_lighting,level_3_lighting_90_1_2019,3,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_dining_bar_lounge_leisure_lighting,level_3_lighting_90_1_2019,4,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_dining_cafeteria_fast_food_lighting,level_3_lighting_90_1_2019,5,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_dining_family_lighting,level_3_lighting_90_1_2019,6,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_dormitory_lighting,level_3_lighting_90_1_2019,7,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_exercise_center_lighting,level_3_lighting_90_1_2019,8,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_fire_station_lighting,level_3_lighting_90_1_2019,9,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_gymnasium_lighting,level_3_lighting_90_1_2019,10,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_health-care_clinic_lighting,level_3_lighting_90_1_2019,11,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_hospital_lighting,level_3_lighting_90_1_2019,12,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_hotel_motel_lighting,level_3_lighting_90_1_2019,13,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_motion_picture_theater_lighting,level_3_lighting_90_1_2019,16,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_museum_lighting,level_3_lighting_90_1_2019,18,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_parking_garage_lighting,level_3_lighting_90_1_2019,20,default,54,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_penitentiary_lighting,level_3_lighting_90_1_2019,21,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_performing_arts_theater_lighting,level_3_lighting_90_1_2019,22,default,426,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_police_station_lighting,level_3_lighting_90_1_2019,23,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_school_university_lighting,level_3_lighting_90_1_2019,27,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_town_hall_lighting,level_3_lighting_90_1_2019,29,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_retail_lighting,level_3_lighting_90_1_2019,26,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +ba_warehouse_lighting,level_3_lighting_90_1_2019,31,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_gymnasium_lighting,level_3_lighting_90_1_2019,38,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_motion_picture_theater_lighting,level_3_lighting_90_1_2019,39,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_penitentiary_lighting,level_3_lighting_90_1_2019,40,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_performing_arts_theater_lighting,level_3_lighting_90_1_2019,41,default,426,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_religious_buildings_lighting,level_3_lighting_90_1_2019,42,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +audience_seating_area_for_sports_arena_lighting,level_3_lighting_90_1_2019,43,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +classroom_lecture_training_for_penitentiary_lighting,level_3_lighting_90_1_2019,47,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +corridor_transition_for_hospital_lighting,level_3_lighting_90_1_2019,54,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_area_for_penitentiary_lighting,level_3_lighting_90_1_2019,61,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_bar_lounge_leisure_general_lighting,level_3_lighting_90_1_2019,57,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_cafeteria_fast_food_general_lighting,level_3_lighting_90_1_2019,58,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +dining_area_for_family_dining_lighting,level_3_lighting_90_1_2019,60,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lobby_for_hotel_lighting,level_3_lighting_90_1_2019,73,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lobby_for_motion_picture_theater_lighting,level_3_lighting_90_1_2019,74,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lobby_for_performing_arts_theater_lighting,level_3_lighting_90_1_2019,75,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +lounge_recreation_for_hospital_lighting,level_3_lighting_90_1_2019,78,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +office-enclosed_general_lighting,level_3_lighting_90_1_2019,80,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +office_open_plan_lighting,level_3_lighting_90_1_2019,81,default,414,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +automotive_general_lighting,level_3_lighting_90_1_2019,94,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +convention_center_exhibit_space_general_lighting,level_3_lighting_90_1_2019,95,default,431,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +library_reading_area_lighting,level_3_lighting_90_1_2019,111,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +library_stacks_lighting,level_3_lighting_90_1_2019,112,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_facility_detailed_manufacturing_area_lighting,level_3_lighting_90_1_2019,113,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_facility_equipment_room_lighting,level_3_lighting_90_1_2019,114,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting,level_3_lighting_90_1_2019,116,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting,level_3_lighting_90_1_2019,117,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +museum_restoration_room_lighting,level_3_lighting_90_1_2019,119,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +post_office_sorting_area_general_lighting,level_3_lighting_90_1_2019,121,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +religious_buildings_fellowship_hall_lighting,level_3_lighting_90_1_2019,122,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +religious_buildings_worship_pulpit_choir_lighting,level_3_lighting_90_1_2019,123,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +retail_mall_concourse_lighting,level_3_lighting_90_1_2019,125,default,403,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +transportation_facility_ticket_counter_lighting,level_3_lighting_90_1_2019,136,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +warehouse_storage_area_medium_to_bulky_palletized_items_lighting,level_3_lighting_90_1_2019,137,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" +warehouse_storage_area_smaller_hand-carried_items_lighting,level_3_lighting_90_1_2019,138,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" diff --git a/data/openstudio_standards_data/database_files/level_2_lighting_space_types.json b/data/openstudio_standards_data/database_files/level_2_lighting_space_types.json index ca2e6533ee..8364cbe8a9 100644 --- a/data/openstudio_standards_data/database_files/level_2_lighting_space_types.json +++ b/data/openstudio_standards_data/database_files/level_2_lighting_space_types.json @@ -4,4955 +4,5663 @@ "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 122, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "atrium_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 36, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "none_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 126, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 0 + "lighting_space_type_target_illuminance_setpoint": 0, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 46, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "baggage_carousel_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 121, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "banking_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 77, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "classroom_lecture_training_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 48, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 471 + "lighting_space_type_target_illuminance_setpoint": 471, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "computer_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 48, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 710 + "lighting_space_type_target_illuminance_setpoint": 710, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "conference_meeting_multipurpose_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 49, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "confinement_cells_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 79, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "copy_print_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 49, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "corridor_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 52, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "courtroom_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 80, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "datacenterhighite_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 60, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "datacenterlowite_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 60, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 58, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 308 + "lighting_space_type_target_illuminance_setpoint": 308, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dressing_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 59, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "electrical_mechanical_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 60, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "emergency_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 87, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 888 + "lighting_space_type_target_illuminance_setpoint": 888, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "emergency_vehicle_garage_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 83, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "exam_treatment_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 88, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "exercise_area_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 85, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "exhibit_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 108, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 431 + "lighting_space_type_target_illuminance_setpoint": 431, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "guest_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 99, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "imaging_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 97, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "interior_parking_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 110, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 54 + "lighting_space_type_target_illuminance_setpoint": 54, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "judges_chambers_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 81, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "food_preparation_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 61, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 538 + "lighting_space_type_target_illuminance_setpoint": 538, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "laboratory_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 64, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "laundry_washing_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 89, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "library_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 13, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "living_quarters_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 82, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "loading_dock_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 30, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lobby_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 68, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "locker_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 59, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lounge_breakroom_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 70, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 14, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "medical_supply_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 90, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "multifamily_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 17, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "nursery_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 92, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "nurses_station_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 91, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "office_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 19, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 414 + "lighting_space_type_target_illuminance_setpoint": 414, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "office_enclosed_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 71, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "operating_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 93, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 1184 + "lighting_space_type_target_illuminance_setpoint": 1184, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "patient_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 94, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "pharmacy_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 95, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 888 + "lighting_space_type_target_illuminance_setpoint": 888, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "physical_therapy_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 96, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "playing_area_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 86, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "post_office_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 24, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "recovery_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 98, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "recreation_common_living_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 70, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 323 + "lighting_space_type_target_illuminance_setpoint": 323, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "restroom_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 73, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "retail_sales_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 117, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "sleeping_quarters_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 84, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 59 + "lighting_space_type_target_illuminance_setpoint": 59, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "sports_arena_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 28, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 1184 + "lighting_space_type_target_illuminance_setpoint": 1184, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "stairwell_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 74, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "storage_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 34, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "transportation_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 30, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "vehicular_maintenance_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 76, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "workshop_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 32, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "worship_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 25, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_automotive_facility_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 1, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_convention_center_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 2, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_courthouse_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 3, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_dining_bar_lounge_leisure_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 4, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_dining_cafeteria_fast_food_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 5, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_dining_family_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 6, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_dormitory_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 7, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_exercise_center_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 8, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_fire_station_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 23, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_gymnasium_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 9, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_health-care_clinic_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 10, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_hospital_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 11, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_hotel_motel_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 12, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_motion_picture_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 16, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_museum_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 18, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_parking_garage_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 20, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 54 + "lighting_space_type_target_illuminance_setpoint": 54, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_penitentiary_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 21, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_performing_arts_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 22, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 426 + "lighting_space_type_target_illuminance_setpoint": 426, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_police_station_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 23, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_school_university_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 27, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 471 + "lighting_space_type_target_illuminance_setpoint": 471, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_town_hall_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 29, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_retail_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 26, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_warehouse_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 31, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_gymnasium_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 39, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_motion_picture_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 40, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_penitentiary_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 41, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_performing_arts_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 42, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 426 + "lighting_space_type_target_illuminance_setpoint": 426, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_religious_buildings_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 43, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_sports_arena_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 44, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "classroom_lecture_training_for_penitentiary_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 47, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 471 + "lighting_space_type_target_illuminance_setpoint": 471, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "corridor_transition_for_hospital_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 50, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_area_for_penitentiary_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 57, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_bar_lounge_leisure_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 4, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_cafeteria_fast_food_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 5, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_area_for_family_dining_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 54, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lobby_for_hotel_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 65, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lobby_for_motion_picture_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 66, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lobby_for_performing_arts_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 67, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lounge_recreation_for_hospital_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 69, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "office-enclosed_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 71, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "office_open_plan_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 72, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 414 + "lighting_space_type_target_illuminance_setpoint": 414, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "automotive_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 76, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "convention_center_exhibit_space_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 78, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 431 + "lighting_space_type_target_illuminance_setpoint": 431, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "library_reading_area_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 101, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "library_stacks_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 102, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_facility_detailed_manufacturing_area_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 104, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_facility_equipment_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 105, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 106, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 107, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "museum_restoration_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 109, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "post_office_sorting_area_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 111, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "religious_buildings_fellowship_hall_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 112, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "religious_buildings_worship_pulpit_choir_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 113, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "retail_mall_concourse_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 114, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 403 + "lighting_space_type_target_illuminance_setpoint": 403, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "transportation_facility_ticket_counter_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 123, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "warehouse_storage_area_medium_to_bulky_palletized_items_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 125, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "warehouse_storage_area_smaller_hand-carried_items_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2004", "level_3_lighting_code_definition_id": 124, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "airport_concourse_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 125, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "atrium_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 36, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "none_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 129, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 0 + "lighting_space_type_target_illuminance_setpoint": 0, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 46, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "baggage_carousel_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 124, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "banking_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 78, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "classroom_lecture_training_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 48, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 471 + "lighting_space_type_target_illuminance_setpoint": 471, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "computer_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 48, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 710 + "lighting_space_type_target_illuminance_setpoint": 710, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "conference_meeting_multipurpose_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 49, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "confinement_cells_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 80, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "copy_print_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 49, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "corridor_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 52, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "courtroom_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 81, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "datacenterhighite_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 60, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "datacenterlowite_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 60, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 58, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 308 + "lighting_space_type_target_illuminance_setpoint": 308, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dressing_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 59, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "electrical_mechanical_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 60, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "emergency_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 88, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 888 + "lighting_space_type_target_illuminance_setpoint": 888, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "emergency_vehicle_garage_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 84, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "exam_treatment_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 89, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "exercise_area_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 86, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "exhibit_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 109, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 431 + "lighting_space_type_target_illuminance_setpoint": 431, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "guest_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 100, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "imaging_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 98, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "interior_parking_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 111, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 54 + "lighting_space_type_target_illuminance_setpoint": 54, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "judges_chambers_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 82, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "food_preparation_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 61, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 538 + "lighting_space_type_target_illuminance_setpoint": 538, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "laboratory_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 64, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "laundry_washing_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 90, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "library_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 13, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "living_quarters_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 83, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "loading_dock_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 30, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lobby_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 68, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "locker_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 59, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lounge_breakroom_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 70, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 14, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "medical_supply_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 91, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "multifamily_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 17, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "nursery_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 93, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "nurses_station_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 92, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "office_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 19, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 414 + "lighting_space_type_target_illuminance_setpoint": 414, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "office_enclosed_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 71, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "operating_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 94, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 1184 + "lighting_space_type_target_illuminance_setpoint": 1184, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "patient_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 95, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "pharmacy_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 96, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 888 + "lighting_space_type_target_illuminance_setpoint": 888, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "physical_therapy_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 97, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "playing_area_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 87, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "post_office_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 24, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "recovery_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 99, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "recreation_common_living_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 70, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 323 + "lighting_space_type_target_illuminance_setpoint": 323, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "restroom_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 73, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "retail_sales_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 120, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "sleeping_quarters_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 85, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 59 + "lighting_space_type_target_illuminance_setpoint": 59, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "sports_arena_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 28, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 1184 + "lighting_space_type_target_illuminance_setpoint": 1184, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "stairwell_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 75, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "storage_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 34, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "transportation_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 30, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "vehicular_maintenance_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 77, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "workshop_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 32, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "worship_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 25, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_automotive_facility_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 1, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_convention_center_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 2, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_courthouse_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 3, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_dining_bar_lounge_leisure_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 4, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_dining_cafeteria_fast_food_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 5, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_dining_family_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 6, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_dormitory_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 7, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_exercise_center_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 8, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_fire_station_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 23, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_gymnasium_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 9, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_health-care_clinic_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 10, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_hospital_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 11, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_hotel_motel_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 12, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_motion_picture_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 16, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_museum_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 18, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_parking_garage_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 20, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 54 + "lighting_space_type_target_illuminance_setpoint": 54, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_penitentiary_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 21, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_performing_arts_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 22, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 426 + "lighting_space_type_target_illuminance_setpoint": 426, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_police_station_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 23, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_school_university_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 27, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 471 + "lighting_space_type_target_illuminance_setpoint": 471, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_town_hall_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 29, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_retail_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 26, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_warehouse_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 31, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_gymnasium_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 39, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_motion_picture_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 40, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_penitentiary_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 41, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_performing_arts_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 42, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 426 + "lighting_space_type_target_illuminance_setpoint": 426, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_religious_buildings_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 43, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_sports_arena_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 44, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "classroom_lecture_training_for_penitentiary_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 47, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 471 + "lighting_space_type_target_illuminance_setpoint": 471, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "corridor_transition_for_hospital_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 50, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_area_for_penitentiary_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 57, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_bar_lounge_leisure_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 4, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_cafeteria_fast_food_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 5, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_area_for_family_dining_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 54, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lobby_for_hotel_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 65, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lobby_for_motion_picture_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 66, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lobby_for_performing_arts_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 67, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lounge_recreation_for_hospital_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 69, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "office-enclosed_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 71, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "office_open_plan_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 72, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 414 + "lighting_space_type_target_illuminance_setpoint": 414, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "automotive_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 77, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "convention_center_exhibit_space_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 79, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 431 + "lighting_space_type_target_illuminance_setpoint": 431, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "library_reading_area_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 102, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "library_stacks_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 103, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_facility_detailed_manufacturing_area_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 105, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_facility_equipment_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 106, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 107, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 108, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "museum_restoration_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 110, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "post_office_sorting_area_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 112, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "religious_buildings_fellowship_hall_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 113, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "religious_buildings_worship_pulpit_choir_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 114, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "retail_mall_concourse_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 115, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 403 + "lighting_space_type_target_illuminance_setpoint": 403, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "transportation_facility_ticket_counter_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 126, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "warehouse_storage_area_medium_to_bulky_palletized_items_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 128, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "warehouse_storage_area_smaller_hand-carried_items_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2007", "level_3_lighting_code_definition_id": 127, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "airport_concourse_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 128, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "atrium_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 34, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "none_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 133, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 0 + "lighting_space_type_target_illuminance_setpoint": 0, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 36, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "baggage_carousel_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 127, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "banking_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 64, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "classroom_lecture_training_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 39, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 471 + "lighting_space_type_target_illuminance_setpoint": 471, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "computer_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 39, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 710 + "lighting_space_type_target_illuminance_setpoint": 710, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "conference_meeting_multipurpose_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 40, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "confinement_cells_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 67, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "copy_print_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 40, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "corridor_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 41, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "courtroom_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 68, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "datacenterhighite_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 46, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "datacenterlowite_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 46, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 44, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 308 + "lighting_space_type_target_illuminance_setpoint": 308, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dressing_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 113, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "electrical_mechanical_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 46, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "emergency_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 80, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 888 + "lighting_space_type_target_illuminance_setpoint": 888, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "emergency_vehicle_garage_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 74, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "exam_treatment_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 81, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "exercise_area_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 76, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "exhibit_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 107, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 431 + "lighting_space_type_target_illuminance_setpoint": 431, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "guest_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 96, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "imaging_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 91, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "interior_parking_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 109, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 54 + "lighting_space_type_target_illuminance_setpoint": 54, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "judges_chambers_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 69, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "food_preparation_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 47, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 538 + "lighting_space_type_target_illuminance_setpoint": 538, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "laboratory_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 49, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "laundry_washing_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 82, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "library_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 14, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "living_quarters_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 73, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "loading_dock_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 31, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lobby_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 53, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "locker_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 54, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lounge_breakroom_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 55, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 15, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "medical_supply_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 84, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "multifamily_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 18, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "nursery_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 85, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "nurses_station_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 86, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "office_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 20, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 414 + "lighting_space_type_target_illuminance_setpoint": 414, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "office_enclosed_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 56, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "operating_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 87, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 1184 + "lighting_space_type_target_illuminance_setpoint": 1184, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "patient_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 88, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "pharmacy_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 89, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 888 + "lighting_space_type_target_illuminance_setpoint": 888, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "physical_therapy_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 90, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "playing_area_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 78, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "post_office_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 25, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "recovery_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 92, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "recreation_common_living_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 55, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 323 + "lighting_space_type_target_illuminance_setpoint": 323, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "restroom_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 58, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "retail_sales_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 119, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "sleeping_quarters_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 75, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 59 + "lighting_space_type_target_illuminance_setpoint": 59, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "sports_arena_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 29, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 1184 + "lighting_space_type_target_illuminance_setpoint": 1184, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "stairwell_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 60, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "storage_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 61, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "transportation_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 31, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "vehicular_maintenance_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 63, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "workshop_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 33, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "worship_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 26, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_automotive_facility_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 1, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_convention_center_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 2, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_courthouse_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 3, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_dining_bar_lounge_leisure_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 4, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_dining_cafeteria_fast_food_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 5, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_dining_family_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 6, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_dormitory_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 7, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_exercise_center_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 8, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_fire_station_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 9, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_gymnasium_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 10, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_health-care_clinic_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 11, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_hospital_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 12, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_hotel_motel_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 13, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_motion_picture_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 17, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_museum_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 19, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_parking_garage_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 21, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 54 + "lighting_space_type_target_illuminance_setpoint": 54, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_penitentiary_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 22, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_performing_arts_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 23, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 426 + "lighting_space_type_target_illuminance_setpoint": 426, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_police_station_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 24, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_school_university_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 28, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 471 + "lighting_space_type_target_illuminance_setpoint": 471, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_town_hall_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 30, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_retail_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 27, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_warehouse_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 32, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_gymnasium_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 77, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_motion_picture_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 37, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_penitentiary_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 70, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_performing_arts_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 38, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 426 + "lighting_space_type_target_illuminance_setpoint": 426, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_religious_buildings_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 110, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_sports_arena_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 120, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "classroom_lecture_training_for_penitentiary_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 71, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 471 + "lighting_space_type_target_illuminance_setpoint": 471, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "corridor_transition_for_hospital_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 79, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_area_for_penitentiary_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 72, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_bar_lounge_leisure_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 4, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_cafeteria_fast_food_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 5, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_area_for_family_dining_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 43, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lobby_for_hotel_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 97, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lobby_for_motion_picture_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 51, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lobby_for_performing_arts_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 52, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lounge_recreation_for_hospital_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 83, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "office-enclosed_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 56, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "office_open_plan_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 57, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 414 + "lighting_space_type_target_illuminance_setpoint": 414, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "automotive_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 63, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "convention_center_exhibit_space_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 66, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 431 + "lighting_space_type_target_illuminance_setpoint": 431, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "library_reading_area_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 99, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "library_stacks_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 100, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_facility_detailed_manufacturing_area_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 102, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_facility_equipment_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 103, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 105, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 106, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "museum_restoration_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 108, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "post_office_sorting_area_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 126, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "religious_buildings_fellowship_hall_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 111, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "religious_buildings_worship_pulpit_choir_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 112, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "retail_mall_concourse_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 114, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 403 + "lighting_space_type_target_illuminance_setpoint": 403, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "transportation_facility_ticket_counter_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 130, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "warehouse_storage_area_medium_to_bulky_palletized_items_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 132, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "warehouse_storage_area_smaller_hand-carried_items_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2010", "level_3_lighting_code_definition_id": 131, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "airport_concourse_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 140, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "atrium_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 33, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "none_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 143, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 0 + "lighting_space_type_target_illuminance_setpoint": 0, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 36, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "baggage_carousel_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 139, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "banking_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 45, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "classroom_lecture_training_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 47, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 471 + "lighting_space_type_target_illuminance_setpoint": 471, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "computer_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 49, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 710 + "lighting_space_type_target_illuminance_setpoint": 710, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "conference_meeting_multipurpose_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 50, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "confinement_cells_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 51, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "copy_print_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 52, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "corridor_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 53, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "courtroom_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 57, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "datacenterhighite_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 64, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "datacenterlowite_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 64, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 58, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 308 + "lighting_space_type_target_illuminance_setpoint": 308, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dressing_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 128, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "electrical_mechanical_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 64, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "emergency_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 112, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 888 + "lighting_space_type_target_illuminance_setpoint": 888, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "emergency_vehicle_garage_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 65, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "exam_treatment_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 112, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "exercise_area_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 105, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "exhibit_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 122, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 431 + "lighting_space_type_target_illuminance_setpoint": 431, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "guest_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 67, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "imaging_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 113, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "interior_parking_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 84, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 54 + "lighting_space_type_target_illuminance_setpoint": 54, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "judges_chambers_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 57, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "food_preparation_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 66, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 538 + "lighting_space_type_target_illuminance_setpoint": 538, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "laboratory_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 68, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "laundry_washing_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 70, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "library_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 14, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "living_quarters_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 99, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "loading_dock_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 71, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lobby_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 72, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "locker_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 78, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lounge_breakroom_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 46, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 15, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "medical_supply_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 106, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "multifamily_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 17, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "nursery_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 108, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "nurses_station_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 107, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "office_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 19, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 414 + "lighting_space_type_target_illuminance_setpoint": 414, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "office_enclosed_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 81, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "operating_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 114, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 1184 + "lighting_space_type_target_illuminance_setpoint": 1184, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "patient_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 109, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "pharmacy_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 106, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 888 + "lighting_space_type_target_illuminance_setpoint": 888, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "physical_therapy_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 110, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "playing_area_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 104, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "post_office_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 24, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "recovery_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 111, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "recreation_common_living_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 79, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 323 + "lighting_space_type_target_illuminance_setpoint": 323, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "restroom_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 86, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "retail_sales_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 88, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "sleeping_quarters_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 103, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 59 + "lighting_space_type_target_illuminance_setpoint": 59, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "sports_arena_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 28, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 1184 + "lighting_space_type_target_illuminance_setpoint": 1184, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "stairwell_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 91, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "storage_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 94, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "transportation_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 30, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "vehicular_maintenance_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 95, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "workshop_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 32, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "worship_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 25, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_automotive_facility_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 1, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_convention_center_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 2, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_courthouse_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 3, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_dining_bar_lounge_leisure_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 4, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_dining_cafeteria_fast_food_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 5, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_dining_family_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 6, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_dormitory_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 7, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_exercise_center_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 8, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_fire_station_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 9, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_gymnasium_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 10, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_health-care_clinic_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 11, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_hospital_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 12, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_hotel_motel_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 13, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_motion_picture_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 16, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_museum_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 18, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_parking_garage_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 20, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 54 + "lighting_space_type_target_illuminance_setpoint": 54, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_penitentiary_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 21, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_performing_arts_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 22, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 426 + "lighting_space_type_target_illuminance_setpoint": 426, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_police_station_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 23, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_school_university_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 27, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 471 + "lighting_space_type_target_illuminance_setpoint": 471, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_town_hall_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 29, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_retail_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 26, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_warehouse_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 31, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_gymnasium_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 38, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_motion_picture_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 39, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_penitentiary_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 40, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_performing_arts_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 41, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 426 + "lighting_space_type_target_illuminance_setpoint": 426, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_religious_buildings_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 42, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_sports_arena_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 43, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "classroom_lecture_training_for_penitentiary_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 48, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 471 + "lighting_space_type_target_illuminance_setpoint": 471, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "corridor_transition_for_hospital_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 55, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_area_for_penitentiary_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 60, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_bar_lounge_leisure_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 4, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_cafeteria_fast_food_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 5, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_area_for_family_dining_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 63, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lobby_for_hotel_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 75, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lobby_for_motion_picture_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 76, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lobby_for_performing_arts_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 77, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lounge_recreation_for_hospital_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 80, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "office-enclosed_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 81, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "office_open_plan_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 83, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 414 + "lighting_space_type_target_illuminance_setpoint": 414, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "automotive_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 97, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "convention_center_exhibit_space_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 98, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 431 + "lighting_space_type_target_illuminance_setpoint": 431, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "library_reading_area_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 115, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "library_stacks_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 116, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_facility_detailed_manufacturing_area_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 117, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_facility_equipment_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 120, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 118, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 119, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "museum_restoration_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 123, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "post_office_sorting_area_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 125, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "religious_buildings_fellowship_hall_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 127, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "religious_buildings_worship_pulpit_choir_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 126, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "retail_mall_concourse_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 129, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 403 + "lighting_space_type_target_illuminance_setpoint": 403, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "transportation_facility_ticket_counter_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 138, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "warehouse_storage_area_medium_to_bulky_palletized_items_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 141, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "warehouse_storage_area_smaller_hand-carried_items_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2013", "level_3_lighting_code_definition_id": 142, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "airport_concourse_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 137, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "atrium_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 33, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "none_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 142, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 0 + "lighting_space_type_target_illuminance_setpoint": 0, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 36, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "baggage_carousel_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 138, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "banking_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 45, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "classroom_lecture_training_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 47, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 471 + "lighting_space_type_target_illuminance_setpoint": 471, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "computer_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 49, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 710 + "lighting_space_type_target_illuminance_setpoint": 710, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "conference_meeting_multipurpose_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 50, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "confinement_cells_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 51, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "copy_print_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 52, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "corridor_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 53, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "courtroom_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 57, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "datacenterhighite_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 64, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "datacenterlowite_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 64, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 58, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 308 + "lighting_space_type_target_illuminance_setpoint": 308, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dressing_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 127, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "electrical_mechanical_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 64, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "emergency_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 105, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 888 + "lighting_space_type_target_illuminance_setpoint": 888, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "emergency_vehicle_garage_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 65, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "exam_treatment_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 105, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "exercise_area_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 103, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "exhibit_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 121, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 431 + "lighting_space_type_target_illuminance_setpoint": 431, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "guest_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 67, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "imaging_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 106, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "interior_parking_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 84, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 54 + "lighting_space_type_target_illuminance_setpoint": 54, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "judges_chambers_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 57, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "food_preparation_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 66, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 538 + "lighting_space_type_target_illuminance_setpoint": 538, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "laboratory_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 68, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "laundry_washing_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 70, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "library_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 14, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "living_quarters_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 99, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "loading_dock_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 71, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lobby_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 72, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "locker_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 78, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lounge_breakroom_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 46, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 15, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "medical_supply_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 107, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "multifamily_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 17, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "nursery_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 109, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "nurses_station_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 108, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "office_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 19, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 414 + "lighting_space_type_target_illuminance_setpoint": 414, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "office_enclosed_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 81, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "operating_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 110, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 1184 + "lighting_space_type_target_illuminance_setpoint": 1184, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "patient_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 111, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "pharmacy_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 107, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 888 + "lighting_space_type_target_illuminance_setpoint": 888, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "physical_therapy_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 112, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "playing_area_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 104, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "post_office_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 24, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "recovery_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 113, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "recreation_common_living_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 79, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 323 + "lighting_space_type_target_illuminance_setpoint": 323, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "restroom_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 86, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "retail_sales_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 88, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "sleeping_quarters_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 102, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 59 + "lighting_space_type_target_illuminance_setpoint": 59, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "sports_arena_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 28, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 1184 + "lighting_space_type_target_illuminance_setpoint": 1184, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "stairwell_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 91, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "storage_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 94, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "transportation_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 30, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "vehicular_maintenance_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 95, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "workshop_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 32, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "worship_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 25, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_automotive_facility_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 1, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_convention_center_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 2, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_courthouse_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 3, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_dining_bar_lounge_leisure_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 4, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_dining_cafeteria_fast_food_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 5, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_dining_family_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 6, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_dormitory_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 7, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_exercise_center_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 8, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_fire_station_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 9, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_gymnasium_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 10, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_health-care_clinic_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 11, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_hospital_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 12, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_hotel_motel_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 13, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_motion_picture_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 16, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_museum_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 18, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_parking_garage_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 20, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 54 + "lighting_space_type_target_illuminance_setpoint": 54, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_penitentiary_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 21, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_performing_arts_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 22, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 426 + "lighting_space_type_target_illuminance_setpoint": 426, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_police_station_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 23, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_school_university_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 27, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 471 + "lighting_space_type_target_illuminance_setpoint": 471, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_town_hall_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 29, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_retail_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 26, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_warehouse_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 31, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_gymnasium_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 39, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_motion_picture_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 40, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_penitentiary_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 41, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_performing_arts_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 42, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 426 + "lighting_space_type_target_illuminance_setpoint": 426, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_religious_buildings_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 43, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_sports_arena_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 44, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "classroom_lecture_training_for_penitentiary_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 48, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 471 + "lighting_space_type_target_illuminance_setpoint": 471, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "corridor_transition_for_hospital_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 55, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_area_for_penitentiary_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 61, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_bar_lounge_leisure_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 4, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_cafeteria_fast_food_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 5, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_area_for_family_dining_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 62, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lobby_for_hotel_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 75, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lobby_for_motion_picture_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 76, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lobby_for_performing_arts_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 77, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lounge_recreation_for_hospital_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 80, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "office-enclosed_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 81, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "office_open_plan_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 83, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 414 + "lighting_space_type_target_illuminance_setpoint": 414, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "automotive_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 97, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "convention_center_exhibit_space_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 98, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 431 + "lighting_space_type_target_illuminance_setpoint": 431, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "library_reading_area_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 114, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "library_stacks_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 115, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_facility_detailed_manufacturing_area_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 116, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_facility_equipment_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 117, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 119, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 120, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "museum_restoration_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 122, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "post_office_sorting_area_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 124, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "religious_buildings_fellowship_hall_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 125, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "religious_buildings_worship_pulpit_choir_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 126, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "retail_mall_concourse_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 128, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 403 + "lighting_space_type_target_illuminance_setpoint": 403, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "transportation_facility_ticket_counter_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 139, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "warehouse_storage_area_medium_to_bulky_palletized_items_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 140, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "warehouse_storage_area_smaller_hand-carried_items_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2016", "level_3_lighting_code_definition_id": 141, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "airport_concourse_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 134, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "atrium_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 33, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "none_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 139, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 0 + "lighting_space_type_target_illuminance_setpoint": 0, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 36, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "baggage_carousel_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 135, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "banking_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 44, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "classroom_lecture_training_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 46, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 471 + "lighting_space_type_target_illuminance_setpoint": 471, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "computer_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 48, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 710 + "lighting_space_type_target_illuminance_setpoint": 710, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "conference_meeting_multipurpose_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 49, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "confinement_cells_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 50, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "copy_print_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 51, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "corridor_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 52, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "courtroom_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 55, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "datacenterhighite_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 62, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "datacenterlowite_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 62, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 56, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 308 + "lighting_space_type_target_illuminance_setpoint": 308, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dressing_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 124, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "electrical_mechanical_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 62, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "emergency_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 102, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 888 + "lighting_space_type_target_illuminance_setpoint": 888, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "emergency_vehicle_garage_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 63, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "exam_treatment_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 102, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "exercise_area_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 100, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "exhibit_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 118, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 431 + "lighting_space_type_target_illuminance_setpoint": 431, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "guest_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 65, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "imaging_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 103, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "interior_parking_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 82, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 54 + "lighting_space_type_target_illuminance_setpoint": 54, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "judges_chambers_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 55, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "food_preparation_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 64, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 538 + "lighting_space_type_target_illuminance_setpoint": 538, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "laboratory_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 66, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "laundry_washing_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 68, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "library_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 14, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "living_quarters_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 96, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "loading_dock_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 69, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lobby_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 70, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "locker_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 76, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lounge_breakroom_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 45, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 15, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "medical_supply_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 104, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "multifamily_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 17, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "nursery_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 105, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "nurses_station_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 106, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "office_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 19, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 414 + "lighting_space_type_target_illuminance_setpoint": 414, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "office_enclosed_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 79, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "operating_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 107, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 1184 + "lighting_space_type_target_illuminance_setpoint": 1184, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "patient_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 108, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "pharmacy_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 104, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 888 + "lighting_space_type_target_illuminance_setpoint": 888, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "physical_therapy_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 109, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "playing_area_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 101, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "post_office_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 24, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "recovery_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 110, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "recreation_common_living_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 77, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 323 + "lighting_space_type_target_illuminance_setpoint": 323, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "restroom_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 84, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "retail_sales_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 86, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "sleeping_quarters_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 99, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 59 + "lighting_space_type_target_illuminance_setpoint": 59, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "sports_arena_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 28, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 1184 + "lighting_space_type_target_illuminance_setpoint": 1184, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "stairwell_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 89, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "storage_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 91, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "transportation_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 30, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "vehicular_maintenance_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 92, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "workshop_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 32, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "worship_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 25, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_automotive_facility_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 1, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_convention_center_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 2, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_courthouse_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 3, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_dining_bar_lounge_leisure_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 4, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_dining_cafeteria_fast_food_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 5, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_dining_family_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 6, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_dormitory_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 7, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_exercise_center_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 8, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_fire_station_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 9, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_gymnasium_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 10, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_health-care_clinic_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 11, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_hospital_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 12, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_hotel_motel_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 13, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_motion_picture_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 16, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_museum_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 18, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_parking_garage_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 20, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 54 + "lighting_space_type_target_illuminance_setpoint": 54, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_penitentiary_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 21, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_performing_arts_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 22, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 426 + "lighting_space_type_target_illuminance_setpoint": 426, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_police_station_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 23, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_school_university_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 27, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 471 + "lighting_space_type_target_illuminance_setpoint": 471, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_town_hall_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 29, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_retail_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 26, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "ba_warehouse_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 31, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_gymnasium_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 38, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_motion_picture_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 39, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_penitentiary_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 40, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_performing_arts_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 41, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 426 + "lighting_space_type_target_illuminance_setpoint": 426, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_religious_buildings_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 42, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "audience_seating_area_for_sports_arena_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 43, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "classroom_lecture_training_for_penitentiary_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 47, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 471 + "lighting_space_type_target_illuminance_setpoint": 471, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "corridor_transition_for_hospital_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 54, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_area_for_penitentiary_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 61, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_bar_lounge_leisure_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 57, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_cafeteria_fast_food_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 58, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "dining_area_for_family_dining_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 60, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lobby_for_hotel_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 73, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 178 + "lighting_space_type_target_illuminance_setpoint": 178, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lobby_for_motion_picture_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 74, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 118 + "lighting_space_type_target_illuminance_setpoint": 118, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lobby_for_performing_arts_theater_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 75, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "lounge_recreation_for_hospital_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 78, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "office-enclosed_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 80, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "office_open_plan_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 81, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 414 + "lighting_space_type_target_illuminance_setpoint": 414, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "automotive_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 94, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "convention_center_exhibit_space_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 95, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 431 + "lighting_space_type_target_illuminance_setpoint": 431, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "library_reading_area_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 111, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "library_stacks_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 112, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_facility_detailed_manufacturing_area_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 113, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_facility_equipment_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 114, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 116, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 117, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "museum_restoration_room_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 119, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 592 + "lighting_space_type_target_illuminance_setpoint": 592, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "post_office_sorting_area_general_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 121, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 474 + "lighting_space_type_target_illuminance_setpoint": 474, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "religious_buildings_fellowship_hall_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 122, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "religious_buildings_worship_pulpit_choir_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 123, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "retail_mall_concourse_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 125, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 403 + "lighting_space_type_target_illuminance_setpoint": 403, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "transportation_facility_ticket_counter_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 136, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 296 + "lighting_space_type_target_illuminance_setpoint": 296, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "warehouse_storage_area_medium_to_bulky_palletized_items_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 137, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 355 + "lighting_space_type_target_illuminance_setpoint": 355, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { "lighting_space_type_name": "warehouse_storage_area_smaller_hand-carried_items_lighting", "level_3_lighting_code_definition_table": "level_3_lighting_90_1_2019", "level_3_lighting_code_definition_id": 138, "lighting_technology_name": "default", - "lighting_space_type_target_illuminance_setpoint": 237 + "lighting_space_type_target_illuminance_setpoint": 237, + "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" } ] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/level_2_natural_gas_equipment.csv b/data/openstudio_standards_data/database_files/level_2_natural_gas_equipment.csv index c77fc657c4..ef5887559a 100644 --- a/data/openstudio_standards_data/database_files/level_2_natural_gas_equipment.csv +++ b/data/openstudio_standards_data/database_files/level_2_natural_gas_equipment.csv @@ -1,7 +1,7 @@ -natural_gas_equipment_space_type_name,natural_gas_equipment_minimum_epd,natural_gas_equipment_average_epd,natural_gas_equipment_median_epd,natural_gas_equipment_maximum_epd,natural_gas_equipment_epd_unit -kitchen,51.16,361.7807576,302.6,767,Btu/hr.ft2 -laundry,42.6,138.4291667,129.9,170,Btu/hr.ft2 -or,17.4,23.223,23.87,23.87,Btu/hr.ft2 -deli,8.52,8.5225,8.52,8.53,Btu/hr.ft2 -bakery,8.53,8.5375,8.54,8.54,Btu/hr.ft2 -deli/bakery,6.25,6.25,6.25,6.25,Btu/hr.ft2 +natural_gas_equipment_space_type_name,natural_gas_equipment_minimum_epd,natural_gas_equipment_average_epd,natural_gas_equipment_median_epd,natural_gas_equipment_maximum_epd,natural_gas_equipment_epd_unit,natural_gas_equipment_fraction_latent,natural_gas_equipment_fraction_radiant,natural_gas_equipment_fraction_lost +kitchen,51.16,361.7807576,302.6,767,Btu/hr.ft2,0.1,0.2,0.7 +laundry,42.6,138.4291667,129.9,170,Btu/hr.ft2,0,0.5,0 +or,17.4,23.223,23.87,23.87,Btu/hr.ft2,0,0,0.5 +deli,8.52,8.5225,8.52,8.53,Btu/hr.ft2,0.1,0.2,0.7 +bakery,8.53,8.5375,8.54,8.54,Btu/hr.ft2,0.1,0.2,0.7 +deli/bakery,6.25,6.25,6.25,6.25,Btu/hr.ft2,0.1,0.2,0.7 diff --git a/data/openstudio_standards_data/database_files/level_2_natural_gas_equipment.json b/data/openstudio_standards_data/database_files/level_2_natural_gas_equipment.json index 70ad2e43eb..aef2798e52 100644 --- a/data/openstudio_standards_data/database_files/level_2_natural_gas_equipment.json +++ b/data/openstudio_standards_data/database_files/level_2_natural_gas_equipment.json @@ -5,7 +5,10 @@ "natural_gas_equipment_average_epd": 361.7807576, "natural_gas_equipment_median_epd": 302.6, "natural_gas_equipment_maximum_epd": 767, - "natural_gas_equipment_epd_unit": "Btu/hr.ft2" + "natural_gas_equipment_epd_unit": "Btu/hr.ft2", + "natural_gas_equipment_fraction_latent": 0.1, + "natural_gas_equipment_fraction_radiant": 0.2, + "natural_gas_equipment_fraction_lost": 0.7 }, { "natural_gas_equipment_space_type_name": "laundry", @@ -13,7 +16,10 @@ "natural_gas_equipment_average_epd": 138.4291667, "natural_gas_equipment_median_epd": 129.9, "natural_gas_equipment_maximum_epd": 170, - "natural_gas_equipment_epd_unit": "Btu/hr.ft2" + "natural_gas_equipment_epd_unit": "Btu/hr.ft2", + "natural_gas_equipment_fraction_latent": 0, + "natural_gas_equipment_fraction_radiant": 0.5, + "natural_gas_equipment_fraction_lost": 0 }, { "natural_gas_equipment_space_type_name": "or", @@ -21,15 +27,21 @@ "natural_gas_equipment_average_epd": 23.223, "natural_gas_equipment_median_epd": 23.87, "natural_gas_equipment_maximum_epd": 23.87, - "natural_gas_equipment_epd_unit": "Btu/hr.ft2" + "natural_gas_equipment_epd_unit": "Btu/hr.ft2", + "natural_gas_equipment_fraction_latent": 0, + "natural_gas_equipment_fraction_radiant": 0, + "natural_gas_equipment_fraction_lost": 0.5 }, { - "natural_gas_equipment_space_type_name": "Deli/Bakery", + "natural_gas_equipment_space_type_name": "deli", "natural_gas_equipment_minimum_epd": 8.52, "natural_gas_equipment_average_epd": 8.5225, "natural_gas_equipment_median_epd": 8.52, "natural_gas_equipment_maximum_epd": 8.53, - "natural_gas_equipment_epd_unit": "Btu/hr.ft2" + "natural_gas_equipment_epd_unit": "Btu/hr.ft2", + "natural_gas_equipment_fraction_latent": 0.1, + "natural_gas_equipment_fraction_radiant": 0.2, + "natural_gas_equipment_fraction_lost": 0.7 }, { "natural_gas_equipment_space_type_name": "bakery", @@ -37,7 +49,10 @@ "natural_gas_equipment_average_epd": 8.5375, "natural_gas_equipment_median_epd": 8.54, "natural_gas_equipment_maximum_epd": 8.54, - "natural_gas_equipment_epd_unit": "Btu/hr.ft2" + "natural_gas_equipment_epd_unit": "Btu/hr.ft2", + "natural_gas_equipment_fraction_latent": 0.1, + "natural_gas_equipment_fraction_radiant": 0.2, + "natural_gas_equipment_fraction_lost": 0.7 }, { "natural_gas_equipment_space_type_name": "deli/bakery", @@ -45,6 +60,9 @@ "natural_gas_equipment_average_epd": 6.25, "natural_gas_equipment_median_epd": 6.25, "natural_gas_equipment_maximum_epd": 6.25, - "natural_gas_equipment_epd_unit": "Btu/hr.ft2" + "natural_gas_equipment_epd_unit": "Btu/hr.ft2", + "natural_gas_equipment_fraction_latent": 0.1, + "natural_gas_equipment_fraction_radiant": 0.2, + "natural_gas_equipment_fraction_lost": 0.7 } ] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.csv b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.csv index 7effe8de98..3fda2e7735 100644 --- a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.csv +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.csv @@ -98,10 +98,10 @@ CS,Audience Seating Area,Sports Arena,0.43,W/ft2,4,,REQ,REQ,,ADD2,ADD2 SS,Transportation Facility,Airport Concourse,0.31,W/ft2,4,REQ,REQ,,ADD2,ADD2, SS,Transportation Facility,Baggage/carousel Area,0.46,W/ft2,4,REQ,REQ,,ADD2,ADD2, SS,Facility For The Visually Impaired,Chapel (used Primarily By Residents),1.06,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Sports Arena—playing Area,Class I Facility,2.47,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Sports Arena—playing Area,Class II Facility,1.96,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Sports Arena—playing Area,Class Iii Facility,1.7,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Sports Arena—playing Area,Class Iv Facility,1.13,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Sports Arena-playing Area,Class I Facility,2.47,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Sports Arena-playing Area,Class II Facility,1.96,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Sports Arena-playing Area,Class Iii Facility,1.7,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Sports Arena-playing Area,Class Iv Facility,1.13,W/ft2,4,REQ,REQ,,ADD2,ADD2, SS,Manufacturing Facility,Detailed Manufacturing Area,0.93,W/ft2,4,REQ,REQ,,ADD2,ADD2, SS,Retail Facilities,Dressing/Fitting Room,0.5,W/ft2,8,,REQ,,REQ,, SS,Manufacturing Facility,Equipment Room,0.65,W/ft2,6,REQ,REQ,,ADD2,ADD2, @@ -110,18 +110,18 @@ SS,Gymnasium/fitness Center,Exercise Area,0.5,W/ft2,4,REQ,REQ,,ADD2,ADD2, SS,Manufacturing Facility,Extra High Bay Area (>50 Ft Floor-to-ceiling Height),1.05,W/ft2,4,REQ,REQ,,ADD2,ADD2, SS,Religious Facility,Fellowship Hall,0.55,W/ft2,4,REQ,REQ,,ADD2,ADD2, SS,Automotive,General,0.56,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Convention Center—exhibit Space,General,0.88,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Dormitory—living Quarters,General,0.54,W/ft2,8,,,,,, -SS,Fire Station—sleeping Quarters,General,0.2,W/ft2,6,,,,,, -SS,Performing Arts Theater—dressing Room,General,0.36,W/ft2,6,REQ,REQ,,REQ,, -SS,Post Office—sorting Area,General,0.68,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, +SS,Convention Center-exhibit Space,General,0.88,W/ft2,4,REQ,REQ,,ADD2,ADD2, +SS,Dormitory-living Quarters,General,0.54,W/ft2,8,,,,,, +SS,Fire Station-sleeping Quarters,General,0.2,W/ft2,6,,,,,, +SS,Performing Arts Theater-dressing Room,General,0.36,W/ft2,6,REQ,REQ,,REQ,, +SS,Post Office-sorting Area,General,0.68,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, SS,Museum,General Exhibition Area,1.05,W/ft2,6,REQ,REQ,,ADD2,ADD2, SS,Manufacturing Facility,High Bay Area (25 To 50 Ft Floor-to-ceiling Height),0.75,W/ft2,4,REQ,REQ,,ADD2,ADD2, SS,Healthcare Facility,Imaging Room,1.06,W/ft2,6,,,,ADD2,ADD2, SS,Manufacturing Facility,Low Bay Area (<25 Ft Floor-to-ceiling Height),0.96,W/ft2,4,REQ,REQ,,ADD2,ADD2, SS,Retail Facilities,Mall Concourse,0.9,W/ft2,4,REQ,REQ,,ADD2,ADD2, SS,Healthcare Facility,Medical Supply Room,0.54,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, -SS,Warehouse—storage Area,"Medium To Bulky, Palletized Items",0.35,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, +SS,Warehouse-storage Area,"Medium To Bulky, Palletized Items",0.35,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, SS,Healthcare Facility,Nurse’s Station,0.81,W/ft2,6,REQ,REQ,,ADD2,ADD2, SS,Healthcare Facility,Nursery,1,W/ft2,6,REQ,REQ,,ADD2,ADD2, SS,Healthcare Facility,Operating Room,2.17,W/ft2,6,,,,ADD2,ADD2, @@ -136,7 +136,7 @@ SS,Retail,Sales Additional (type 1),0.45,W/ft2,4,REQ,REQ,,ADD2,ADD2, SS,Retail,Sales Additional (type 2),0.45,W/ft2,4,REQ,REQ,,ADD2,ADD2, SS,Retail,Sales Additional (type 3),1.05,W/ft2,4,REQ,REQ,,ADD2,ADD2, SS,Retail,Sales Additional (type 4),1.88,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Warehouse—storage Area,"Smaller, Hand-carried Items",0.69,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, +SS,Warehouse-storage Area,"Smaller, Hand-carried Items",0.69,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, SS,Library,Stacks,1.2,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, SS,Transportation Facility,Terminal Ticket Counter,0.62,W/ft2,4,REQ,REQ,,ADD2,ADD2, SS,Religious Facility,Worship/Pulpit/Choir Area,1.53,W/ft2,4,REQ,REQ,,ADD2,ADD2, diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.json b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.json index dac50ddbe7..ae014f65c9 100644 --- a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.json +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.json @@ -1387,7 +1387,7 @@ }, { "method": "SS", - "lighting_primary_space_type": "Sports Arena\u00e2\u20ac\u201dplaying Area", + "lighting_primary_space_type": "Sports Arena-playing Area", "lighting_secondary_space_type": "Class I Facility", "lighting_power_density": 2.47, "unit": "W/ft2", @@ -1401,7 +1401,7 @@ }, { "method": "SS", - "lighting_primary_space_type": "Sports Arena\u00e2\u20ac\u201dplaying Area", + "lighting_primary_space_type": "Sports Arena-playing Area", "lighting_secondary_space_type": "Class II Facility", "lighting_power_density": 1.96, "unit": "W/ft2", @@ -1415,7 +1415,7 @@ }, { "method": "SS", - "lighting_primary_space_type": "Sports Arena\u00e2\u20ac\u201dplaying Area", + "lighting_primary_space_type": "Sports Arena-playing Area", "lighting_secondary_space_type": "Class Iii Facility", "lighting_power_density": 1.7, "unit": "W/ft2", @@ -1429,7 +1429,7 @@ }, { "method": "SS", - "lighting_primary_space_type": "Sports Arena\u00e2\u20ac\u201dplaying Area", + "lighting_primary_space_type": "Sports Arena-playing Area", "lighting_secondary_space_type": "Class Iv Facility", "lighting_power_density": 1.13, "unit": "W/ft2", @@ -1555,7 +1555,7 @@ }, { "method": "SS", - "lighting_primary_space_type": "Convention Center\u00e2\u20ac\u201dexhibit Space", + "lighting_primary_space_type": "Convention Center-exhibit Space", "lighting_secondary_space_type": "General", "lighting_power_density": 0.88, "unit": "W/ft2", @@ -1569,7 +1569,7 @@ }, { "method": "SS", - "lighting_primary_space_type": "Dormitory\u00e2\u20ac\u201dliving Quarters", + "lighting_primary_space_type": "Dormitory-living Quarters", "lighting_secondary_space_type": "General", "lighting_power_density": 0.54, "unit": "W/ft2", @@ -1583,7 +1583,7 @@ }, { "method": "SS", - "lighting_primary_space_type": "Fire Station\u00e2\u20ac\u201dsleeping Quarters", + "lighting_primary_space_type": "Fire Station-sleeping Quarters", "lighting_secondary_space_type": "General", "lighting_power_density": 0.2, "unit": "W/ft2", @@ -1597,7 +1597,7 @@ }, { "method": "SS", - "lighting_primary_space_type": "Performing Arts Theater\u00e2\u20ac\u201ddressing Room", + "lighting_primary_space_type": "Performing Arts Theater-dressing Room", "lighting_secondary_space_type": "General", "lighting_power_density": 0.36, "unit": "W/ft2", @@ -1611,7 +1611,7 @@ }, { "method": "SS", - "lighting_primary_space_type": "Post Office\u00e2\u20ac\u201dsorting Area", + "lighting_primary_space_type": "Post Office-sorting Area", "lighting_secondary_space_type": "General", "lighting_power_density": 0.68, "unit": "W/ft2", @@ -1709,7 +1709,7 @@ }, { "method": "SS", - "lighting_primary_space_type": "Warehouse\u00e2\u20ac\u201dstorage Area", + "lighting_primary_space_type": "Warehouse-storage Area", "lighting_secondary_space_type": "Medium To Bulky, Palletized Items", "lighting_power_density": 0.35, "unit": "W/ft2", @@ -1724,7 +1724,7 @@ { "method": "SS", "lighting_primary_space_type": "Healthcare Facility", - "lighting_secondary_space_type": "Nurse\u00e2\u20ac\u2122s Station", + "lighting_secondary_space_type": "Nurse\u00c3\u00a2\u00e2\u201a\u00ac\u00e2\u201e\u00a2s Station", "lighting_power_density": 0.81, "unit": "W/ft2", "rcr_threshold": 6, @@ -1919,7 +1919,7 @@ }, { "method": "SS", - "lighting_primary_space_type": "Warehouse\u00e2\u20ac\u201dstorage Area", + "lighting_primary_space_type": "Warehouse-storage Area", "lighting_secondary_space_type": "Smaller, Hand-carried Items", "lighting_power_density": 0.69, "unit": "W/ft2", diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2007.csv b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2007.csv index 193bd79b61..82e93a4e95 100644 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2007.csv +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2007.csv @@ -51,7 +51,7 @@ Public Assembly Spaces,Courtrooms,5,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, Public Assembly Spaces,Legislative chambers,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, Public Assembly Spaces,Libraries,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, Public Assembly Spaces,Lobbies,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -Public Assembly Spaces,Museums (children�s),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, +Public Assembly Spaces,Museums (children's),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, Public Assembly Spaces,Museums/galleries,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, Residential,Dwelling unit,5,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, Residential,Common corridors,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2007.json b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2007.json index bc9d2636f2..f1a30c0de0 100644 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2007.json +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2007.json @@ -677,7 +677,7 @@ }, { "ventilation_primary_space_type": "Public Assembly Spaces", - "ventilation_secondary_space_type": "Museums (children\u00c3\u0192\u00c2\u00af\u00c3\u201a\u00c2\u00bf\u00c3\u201a\u00c2\u00bds)", + "ventilation_secondary_space_type": "Museums (children's)", "ventilation_rate_occupant": 7.5, "ventilation_rate_occupant_unit": "cfm/person", "ventilation_rate_area": 0.12, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2010.csv b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2010.csv index f6b734428e..1bf2cf36cc 100644 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2010.csv +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2010.csv @@ -55,7 +55,7 @@ Public Assembly Spaces,Courtrooms,5,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, Public Assembly Spaces,Legislative chambers,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, Public Assembly Spaces,Libraries,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, Public Assembly Spaces,Lobbies,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -Public Assembly Spaces,Museums (children�s),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, +Public Assembly Spaces,Museums (children's),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, Public Assembly Spaces,Museums/galleries,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, Residential,Dwelling unit,5,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, Residential,Common corridors,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2010.json b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2010.json index 5a31889f1a..c751206e0a 100644 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2010.json +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2010.json @@ -729,7 +729,7 @@ }, { "ventilation_primary_space_type": "Public Assembly Spaces", - "ventilation_secondary_space_type": "Museums (children\u00c3\u0192\u00c2\u00af\u00c3\u201a\u00c2\u00bf\u00c3\u201a\u00c2\u00bds)", + "ventilation_secondary_space_type": "Museums (children's)", "ventilation_rate_occupant": 7.5, "ventilation_rate_occupant_unit": "cfm/person", "ventilation_rate_area": 0.12, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2013.csv b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2013.csv index 120109d38e..2db1b9a31f 100644 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2013.csv +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2013.csv @@ -35,7 +35,7 @@ General,Occupiable storage rooms for liquids or gels,5,cfm/person,0.12,cfm/ft2,2 Miscellaneous Spaces,Bank vaults/safe deposit,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,2,, Miscellaneous Spaces,Banks or bank lobbies,7.5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,, Miscellaneous Spaces,Computer (not printing),5,cfm/person,0.06,cfm/ft2,4,ppl/1000 ft2,1,, -Miscellaneous Spaces,Freezer and refrigerated spaces (<50�F),10,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,2,, +Miscellaneous Spaces,Freezer and refrigerated spaces (<50degF),10,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,2,, Miscellaneous Spaces,General manufacturing (excludes heavy industrial and processes using chemicals),10,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,3,, Miscellaneous Spaces,Pharmacy (prep. area),5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, Miscellaneous Spaces,Photo studios,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, @@ -56,7 +56,7 @@ Public Assembly Spaces,Courtrooms,5,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, Public Assembly Spaces,Legislative chambers,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, Public Assembly Spaces,Libraries,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, Public Assembly Spaces,Lobbies,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -Public Assembly Spaces,Museums (children�s),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, +Public Assembly Spaces,Museums (children's),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, Public Assembly Spaces,Museums/galleries,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, Residential,Dwelling unit,5,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, Residential,Common corridors,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2013.json b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2013.json index 7b03e3f74c..06037eae2f 100644 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2013.json +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2013.json @@ -469,7 +469,7 @@ }, { "ventilation_primary_space_type": "Miscellaneous Spaces", - "ventilation_secondary_space_type": "Freezer and refrigerated spaces (<50\u00c3\u0192\u00c2\u00af\u00c3\u201a\u00c2\u00bf\u00c3\u201a\u00c2\u00bdF)", + "ventilation_secondary_space_type": "Freezer and refrigerated spaces (<50degF)", "ventilation_rate_occupant": 10, "ventilation_rate_occupant_unit": "cfm/person", "ventilation_rate_area": 0, @@ -742,7 +742,7 @@ }, { "ventilation_primary_space_type": "Public Assembly Spaces", - "ventilation_secondary_space_type": "Museums (children\u00c3\u0192\u00c2\u00af\u00c3\u201a\u00c2\u00bf\u00c3\u201a\u00c2\u00bds)", + "ventilation_secondary_space_type": "Museums (children's)", "ventilation_rate_occupant": 7.5, "ventilation_rate_occupant_unit": "cfm/person", "ventilation_rate_area": 0.12, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2016.csv b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2016.csv index 120109d38e..2db1b9a31f 100644 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2016.csv +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2016.csv @@ -35,7 +35,7 @@ General,Occupiable storage rooms for liquids or gels,5,cfm/person,0.12,cfm/ft2,2 Miscellaneous Spaces,Bank vaults/safe deposit,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,2,, Miscellaneous Spaces,Banks or bank lobbies,7.5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,, Miscellaneous Spaces,Computer (not printing),5,cfm/person,0.06,cfm/ft2,4,ppl/1000 ft2,1,, -Miscellaneous Spaces,Freezer and refrigerated spaces (<50�F),10,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,2,, +Miscellaneous Spaces,Freezer and refrigerated spaces (<50degF),10,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,2,, Miscellaneous Spaces,General manufacturing (excludes heavy industrial and processes using chemicals),10,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,3,, Miscellaneous Spaces,Pharmacy (prep. area),5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, Miscellaneous Spaces,Photo studios,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, @@ -56,7 +56,7 @@ Public Assembly Spaces,Courtrooms,5,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, Public Assembly Spaces,Legislative chambers,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, Public Assembly Spaces,Libraries,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, Public Assembly Spaces,Lobbies,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -Public Assembly Spaces,Museums (children�s),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, +Public Assembly Spaces,Museums (children's),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, Public Assembly Spaces,Museums/galleries,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, Residential,Dwelling unit,5,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, Residential,Common corridors,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2016.json b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2016.json index 7b03e3f74c..06037eae2f 100644 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2016.json +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2016.json @@ -469,7 +469,7 @@ }, { "ventilation_primary_space_type": "Miscellaneous Spaces", - "ventilation_secondary_space_type": "Freezer and refrigerated spaces (<50\u00c3\u0192\u00c2\u00af\u00c3\u201a\u00c2\u00bf\u00c3\u201a\u00c2\u00bdF)", + "ventilation_secondary_space_type": "Freezer and refrigerated spaces (<50degF)", "ventilation_rate_occupant": 10, "ventilation_rate_occupant_unit": "cfm/person", "ventilation_rate_area": 0, @@ -742,7 +742,7 @@ }, { "ventilation_primary_space_type": "Public Assembly Spaces", - "ventilation_secondary_space_type": "Museums (children\u00c3\u0192\u00c2\u00af\u00c3\u201a\u00c2\u00bf\u00c3\u201a\u00c2\u00bds)", + "ventilation_secondary_space_type": "Museums (children's)", "ventilation_rate_occupant": 7.5, "ventilation_rate_occupant_unit": "cfm/person", "ventilation_rate_area": 0.12, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.csv b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.csv index 03bb813e26..acfc66fb48 100644 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.csv +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.csv @@ -47,7 +47,7 @@ Food and Beverage Service,Restaurant dining rooms,7.5,cfm/person,0.18,cfm/ft2,70 Miscellaneous Spaces,Banks or bank lobbies,7.5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,yes, Miscellaneous Spaces,Bank vaults/safe deposit,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,2,yes, Miscellaneous Spaces,Computer (not printing),5,cfm/person,0.06,cfm/ft2,4,ppl/1000 ft2,1,yes, -Miscellaneous Spaces,Freezer and refrigerated spaces (<50�F [10�C]),10,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,2,, +Miscellaneous Spaces,Freezer and refrigerated spaces (<50degF [10degC]),10,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,2,, Miscellaneous Spaces,Manufacturing where hazardous materials are not used,10,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,2,, Miscellaneous Spaces,Manufacturing where hazardous materials are used (excludes heavy industrial and chemical processes),10,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,3,, Miscellaneous Spaces,Pharmacy (prep. area),5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.json b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.json index be9c84554f..d147be33e1 100644 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.json +++ b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.json @@ -625,7 +625,7 @@ }, { "ventilation_primary_space_type": "Miscellaneous Spaces", - "ventilation_secondary_space_type": "Freezer and refrigerated spaces (<50\u00c3\u0192\u00c2\u00af\u00c3\u201a\u00c2\u00bf\u00c3\u201a\u00c2\u00bdF [10\u00c3\u0192\u00c2\u00af\u00c3\u201a\u00c2\u00bf\u00c3\u201a\u00c2\u00bdC])", + "ventilation_secondary_space_type": "Freezer and refrigerated spaces (<50degF [10degC])", "ventilation_rate_occupant": 10, "ventilation_rate_occupant_unit": "cfm/person", "ventilation_rate_area": 0, diff --git a/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.csv b/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.csv index dee70d0342..425e588ac8 100644 --- a/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.csv +++ b/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.csv @@ -52,3 +52,5 @@ transportation_ticket_counter_electric_equipment vehicular_maintenance_electric_equipment workshop_electric_equipment worship_pulpit_choir_area_electric_equipment +datacenter_high_ite_equipment +datacenter_low_ite_equipment diff --git a/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.json b/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.json index 065ee40161..019799b353 100644 --- a/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.json +++ b/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.json @@ -157,5 +157,11 @@ }, { "support_electric_equipment_space_type_name_tags": "worship_pulpit_choir_area_electric_equipment" + }, + { + "support_electric_equipment_space_type_name_tags": "datacenter_high_ite_equipment" + }, + { + "support_electric_equipment_space_type_name_tags": "datacenter_low_ite_equipment" } ] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_tables/level_1_space_types.py b/data/openstudio_standards_data/database_tables/level_1_space_types.py index 54d1e6b010..60a8036df5 100644 --- a/data/openstudio_standards_data/database_tables/level_1_space_types.py +++ b/data/openstudio_standards_data/database_tables/level_1_space_types.py @@ -11,6 +11,7 @@ electric_equipment_space_type_name: TEXT natural_gas_equipment_space_type_name: TEXT schedule_set_name: TEXT +annotation: TEXT """ CREATE_LEVEL_1_SPACE_TYPES = f""" @@ -22,6 +23,7 @@ electric_equipment_space_type_name TEXT, natural_gas_equipment_space_type_name TEXT, schedule_set_name TEXT, +annotation TEXT, FOREIGN KEY(lighting_space_type_name) REFERENCES support_lighting_space_type_name_tags(lighting_space_type_name) FOREIGN KEY(ventilation_space_type_name) REFERENCES support_ventilation_space_type_name_tags(ventilation_space_type_name) FOREIGN KEY(electric_equipment_space_type_name) REFERENCES support_electric_equipment_space_type_name_tags(support_electric_equipment_space_type_name_tags) @@ -36,9 +38,10 @@ ventilation_space_type_name, electric_equipment_space_type_name, natural_gas_equipment_space_type_name, - schedule_set_name + schedule_set_name, + annotation ) - VALUES (?, ?, ?, ?, ?, ?); + VALUES (?, ?, ?, ?, ?, ?, ?); """ @@ -49,6 +52,7 @@ "electric_equipment_space_type_name": "", "natural_gas_equipment_space_type_name": "", "schedule_set_name": "", + "annotation": "", } @@ -90,4 +94,5 @@ def _preprocess_record(self, record): getattr_either("electric_equipment_space_type_name", record), getattr_either("natural_gas_equipment_space_type_name", record), getattr_either("schedule_set_name", record), + getattr_either("annotation", record), ) diff --git a/data/openstudio_standards_data/database_tables/level_2_electric_equipment.py b/data/openstudio_standards_data/database_tables/level_2_electric_equipment.py index f578448149..e62381be06 100644 --- a/data/openstudio_standards_data/database_tables/level_2_electric_equipment.py +++ b/data/openstudio_standards_data/database_tables/level_2_electric_equipment.py @@ -9,28 +9,45 @@ RECORD_HELP = """ Must provide a tuple that contains: electric_equipment_space_type_name: TEXT -electric_equipment_minimum_epd: REAL -electric_equipment_average_epd: REAL -electric_equipment_median_epd: REAL -electric_equipment_maximum_epd: REAL +electric_equipment_minimum_epd: NUMERIC +electric_equipment_average_epd: NUMERIC +electric_equipment_median_epd: NUMERIC +electric_equipment_maximum_epd: NUMERIC electric_equipment_epd_unit: TEXT +electric_equipment_fraction_latent: NUMERIC +electric_equipment_fraction_radiant: NUMERIC +electric_equipment_fraction_lost: NUMERIC """ CREATE_LEVEL_2_ELECTRIC_EQUIPMENT = """ -CREATE TABLE IF NOT EXISTS %s -(id INTEGER PRIMARY KEY, -electric_equipment_space_type_name TEXT NOT NULL, -electric_equipment_minimum_epd NUMERIC, -electric_equipment_average_epd NUMERIC, -electric_equipment_median_epd NUMERIC, -electric_equipment_maximum_epd NUMERIC, -electric_equipment_epd_unit TEXT); +CREATE TABLE IF NOT EXISTS %s +(id INTEGER PRIMARY KEY, +electric_equipment_space_type_name TEXT NOT NULL, +electric_equipment_minimum_epd NUMERIC, +electric_equipment_average_epd NUMERIC, +electric_equipment_median_epd NUMERIC, +electric_equipment_maximum_epd NUMERIC, +electric_equipment_epd_unit TEXT, +electric_equipment_fraction_latent NUMERIC, +electric_equipment_fraction_radiant NUMERIC, +electric_equipment_fraction_lost NUMERIC +); """ INSERT_EQUIP_LOAD_RECORD = """ INSERT INTO %s - (electric_equipment_space_type_name, electric_equipment_minimum_epd, electric_equipment_average_epd, electric_equipment_median_epd, electric_equipment_maximum_epd, electric_equipment_epd_unit) - VALUES (?, ?, ?, ? , ? ,?); + ( + electric_equipment_space_type_name, + electric_equipment_minimum_epd, + electric_equipment_average_epd, + electric_equipment_median_epd, + electric_equipment_maximum_epd, + electric_equipment_epd_unit, + electric_equipment_fraction_latent, + electric_equipment_fraction_radiant, + electric_equipment_fraction_lost + ) + VALUES (?, ?, ?, ?, ?, ?, ?, ?, ?); """ RECORD_TEMPLATE = { @@ -40,6 +57,9 @@ "electric_equipment_median_epd": "", "electric_equipment_maximum_epd": "", "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0.0, + "electric_equipment_fraction_radiant": 0.0, + "electric_equipment_fraction_lost": 0.0, } @@ -66,6 +86,9 @@ def validate_record_datatype(self, record): "electric_equipment_average_epd", "electric_equipment_median_epd", "electric_equipment_maximum_epd", + "electric_equipment_fraction_latent", + "electric_equipment_fraction_radiant", + "electric_equipment_fraction_lost", ] for f in float_expected: @@ -88,5 +111,8 @@ def _preprocess_record(self, record): getattr_either("electric_equipment_median_epd", record), getattr_either("electric_equipment_maximum_epd", record), getattr_either("electric_equipment_epd_unit", record, ""), + getattr_either("electric_equipment_fraction_latent", record), + getattr_either("electric_equipment_fraction_radiant", record), + getattr_either("electric_equipment_fraction_lost", record), ) return record_tuple diff --git a/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py b/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py index 47c0e5bf6a..457b922cb4 100644 --- a/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py +++ b/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py @@ -20,6 +20,7 @@ level_3_lighting_code_definition_id INTEGER NOT NULL, lighting_technology_name TEXT, lighting_space_type_target_illuminance_setpoint NUMERIC, +annotation TEXT, FOREIGN KEY(lighting_space_type_name) REFERENCES support_lighting_space_type_name_tags(lighting_space_type_name) FOREIGN KEY(lighting_technology_name) REFERENCES support_lighting_technologies(lighting_technology_definition_name) ); @@ -32,9 +33,10 @@ level_3_lighting_code_definition_table, level_3_lighting_code_definition_id, lighting_technology_name, - lighting_space_type_target_illuminance_setpoint + lighting_space_type_target_illuminance_setpoint, + annotation ) - VALUES (?, ?, ?, ?, ?); + VALUES (?, ?, ?, ?, ?, ?); """ RECORD_TEMPLATE = { @@ -43,6 +45,7 @@ "level_3_lighting_code_definition_id": "", "lighting_technology_name": "", "lighting_space_type_target_illuminance_setpoint": 0.0, + "annotation": "", } @@ -81,6 +84,7 @@ def _preprocess_record(self, record): getattr_either("level_3_lighting_code_definition_id", record), getattr_either("lighting_technology_name", record), getattr_either("lighting_space_type_target_illuminance_setpoint", record), + getattr_either("annotation", record), ) return record_list diff --git a/data/openstudio_standards_data/database_tables/level_2_natural_gas_equipment.py b/data/openstudio_standards_data/database_tables/level_2_natural_gas_equipment.py index 65beef817d..276bbaf069 100644 --- a/data/openstudio_standards_data/database_tables/level_2_natural_gas_equipment.py +++ b/data/openstudio_standards_data/database_tables/level_2_natural_gas_equipment.py @@ -9,11 +9,14 @@ RECORD_HELP = """ Must provide a tuple that contains: natural_gas_equipment_space_type_name: TEXT -natural_gas_equipment_minimum_epd: REAL -natural_gas_equipment_average_epd: REAL -natural_gas_equipment_median_epd: REAL -natural_gas_equipment_maximum_epd: REAL +natural_gas_equipment_minimum_epd: NUMERIC +natural_gas_equipment_average_epd: NUMERIC +natural_gas_equipment_median_epd: NUMERIC +natural_gas_equipment_maximum_epd: NUMERIC natural_gas_equipment_epd_unit: TEXT +natural_gas_equipment_fraction_latent: NUMERIC +natural_gas_equipment_fraction_radiant: NUMERIC +natural_gas_equipment_fraction_lost: NUMERIC """ CREATE_NATURAL_GAS_EQUIPMENT_TABLE = """ @@ -24,13 +27,27 @@ natural_gas_equipment_average_epd NUMERIC, natural_gas_equipment_median_epd NUMERIC, natural_gas_equipment_maximum_epd NUMERIC, -natural_gas_equipment_epd_unit TEXT); +natural_gas_equipment_epd_unit TEXT, +natural_gas_equipment_fraction_latent NUMERIC, +natural_gas_equipment_fraction_radiant NUMERIC, +natural_gas_equipment_fraction_lost NUMERIC +); """ INSERT_NATURAL_GAS_EQUIP_LOAD_RECORD = """ INSERT INTO %s - (natural_gas_equipment_space_type_name, natural_gas_equipment_minimum_epd, natural_gas_equipment_average_epd, natural_gas_equipment_median_epd, natural_gas_equipment_maximum_epd, natural_gas_equipment_epd_unit) - VALUES (?, ?, ?, ? , ? ,?); + ( + natural_gas_equipment_space_type_name, + natural_gas_equipment_minimum_epd, + natural_gas_equipment_average_epd, + natural_gas_equipment_median_epd, + natural_gas_equipment_maximum_epd, + natural_gas_equipment_epd_unit, + natural_gas_equipment_fraction_latent, + natural_gas_equipment_fraction_radiant, + natural_gas_equipment_fraction_lost + ) + VALUES (?, ?, ?, ?, ? , ?, ?, ?, ?); """ RECORD_TEMPLATE = { @@ -40,6 +57,9 @@ "natural_gas_equipment_median_epd": "", "natural_gas_equipment_maximum_epd": "", "natural_gas_equipment_epd_unit": "Btu/hr.ft2", + "natural_gas_equipment_fraction_latent": 0.0, + "natural_gas_equipment_fraction_radiant": 0.0, + "natural_gas_equipment_fraction_lost": 0.0, } @@ -66,6 +86,9 @@ def validate_record_datatype(self, record): "natural_gas_equipment_average_epd", "natural_gas_equipment_median_epd", "natural_gas_equipment_maximum_epd", + "natural_gas_equipment_fraction_latent", + "natural_gas_equipment_fraction_radiant", + "natural_gas_equipment_fraction_lost", ] for f in float_expected: @@ -88,5 +111,8 @@ def _preprocess_record(self, record): getattr_either("natural_gas_equipment_median_epd", record), getattr_either("natural_gas_equipment_maximum_epd", record), getattr_either("natural_gas_equipment_epd_unit", record, ""), + getattr_either("natural_gas_equipment_fraction_latent", record), + getattr_either("natural_gas_equipment_fraction_radiant", record), + getattr_either("natural_gas_equipment_fraction_lost", record), ) return record_tuple diff --git a/lib/openstudio-standards/standards/Standards.SpaceType.rb b/lib/openstudio-standards/standards/Standards.SpaceType.rb index b00e2f9fd6..21abca0f5d 100644 --- a/lib/openstudio-standards/standards/Standards.SpaceType.rb +++ b/lib/openstudio-standards/standards/Standards.SpaceType.rb @@ -6,6 +6,9 @@ class Standard # @param space_type [OpenStudio::Model::SpaceType] space type object # @return [hash] hash of internal loads for different load types def space_type_get_standards_data(space_type) + standards_building_type = if space_type.standardsBuildingType.is_initialized + space_type.standardsBuildingType.get + end standards_space_type = if space_type.standardsSpaceType.is_initialized space_type.standardsSpaceType.get end diff --git a/test/doe_prototype/test_medium_office.rb b/test/doe_prototype/test_medium_office.rb index 808b81e81b..dc0958a11e 100644 --- a/test/doe_prototype/test_medium_office.rb +++ b/test/doe_prototype/test_medium_office.rb @@ -3,8 +3,8 @@ class TestMediumOffice < CreateDOEPrototypeBuildingTest building_types = ['MediumOffice'] - templates = ['90.1-2004'] - climate_zones = ['ASHRAE 169-2013-4A'] + templates = ['DOE Ref Pre-1980','DOE Ref 1980-2004','90.1-2007','90.1-2013','90.1-2016','90.1-2019'] + climate_zones = ['ASHRAE 169-2013-2A','ASHRAE 169-2013-3B','ASHRAE 169-2013-5A','ASHRAE 169-2013-8A'] epw_files = ['USA_FL_Miami.Intl.AP.722020_TMY3.epw'] # not used for ASHRAE/DOE archetypes, but required for call create_models = true run_models = false From ddbcb38cd71f19f5e690806cab70d289340f9a54 Mon Sep 17 00:00:00 2001 From: Jeremy L <5149279+lymereJ@users.noreply.github.com> Date: Fri, 31 Mar 2023 13:24:57 -0700 Subject: [PATCH 19/45] Update documentation (#1484) * First pass at updating docs. * Update docs. * Update docs. * Update docs. * Update docs. * Update docs. * Update docs. --- ....yml => openstudio_standards_database.yml} | 0 data/openstudio_standards_data/README.md | 112 +++++++++++++++--- .../database_structure.png | Bin 0 -> 66178 bytes .../plug_loads_methodology.png | Bin 0 -> 64689 bytes 4 files changed, 96 insertions(+), 16 deletions(-) rename .github/workflows/{osstd-database.yml => openstudio_standards_database.yml} (100%) create mode 100644 data/openstudio_standards_data/database_structure.png create mode 100644 data/openstudio_standards_data/plug_loads_methodology.png diff --git a/.github/workflows/osstd-database.yml b/.github/workflows/openstudio_standards_database.yml similarity index 100% rename from .github/workflows/osstd-database.yml rename to .github/workflows/openstudio_standards_database.yml diff --git a/data/openstudio_standards_data/README.md b/data/openstudio_standards_data/README.md index 16df5c004c..f6df2631b5 100644 --- a/data/openstudio_standards_data/README.md +++ b/data/openstudio_standards_data/README.md @@ -1,29 +1,109 @@ -# OpenStudio Standards Data -This folder contains code that manages the data needed by OpenStudio Standards to operate +# OpenStudio-Standards Data +This folder contains the code that manages the data needed by OpenStudio-Standards to operate. The data is managed through an SQLite database. The database is not hosted on the repository but can be easily and quickly created with a few lines of code (see [Quick Start Guide](#quick-start-guide)). The database is managed by code located in the `./database_engine` and `./database_tables` folders. Data used to populate the database tables is located in `./database_files`. Pre-constructed queries and code for other types of applications for the database is located in `./query` and in `./applications`. Some tests to ensure, among others, that the database can be successfully created are located in `./test`. +## Motivation +Using a relational database makes the data management process seamless as the database maintains relationships among the different data tables and performs automatic data validation. Data fed to the database is currently stored in JSON files. This enables version control of the content of the database. As the format of these JSON files is currently different than the one needed by OpenStudio-Standards, functions have been built to automate the export of the data to the required format (see [Quick Start Guide](#quick-start-guide)). ## Prerequisites -Python 3.10 (3.9 could work but not tested) +Below are listed the prerequisites to any of the database related code. +- Python 3.10 +## Database Structure and Covered Data +### Structure +The figure below shows an overview of the structure of the database and of the data management approach. +![Overview of the Database Structure](database_structure.png "Database Structure") +### Covered Data +As shown in the figure above, the database contains two types of data: space type data and non-space type related data. The space type related data is made of three distinct but interconnected levels. -## Quick Start Guide -Clone this repo -To create the full database in your local repo: +- The first level, level 1, corresponds to a single data table that contains a list of space type names supported by OpenStudio-Standards and a mapping to different sub-space type names (such as lighting, ventilation, and equipment, etc.) that can be used to determine general modeling assumption for a space type for a specific building energy code version. +- The second level, level 2, is a collection of data tables that contains lists of sub-space type names and references to different code requirement values. +- The third and final level, level 3, is a collection of data tables that contains raw information from building energy codes, such as lighting power allowances and required ventilation rates. +The list of space type provided in the level 1 table is a concise yet exhaustive list of space type that can be used to model most commercial building spaces. Assumptions for these space types are contained in the level 2 and level 3 tables, however these tables contain additional information about more specific space type requirements (or less specific, e.g., through the building area method lighting power allowances). + +This approach lends itself to customization, for example, the mapping of a particular space type name to sub-space type can be overwritten by changing the reference to the sub-space types (level 2) in the level 1 table. Another possible use of the database is to only access the level 3 data tables to get a direct access to the raw code information in a tabulated format which, again, contains more data than what is used to derive the modeling assumptions for the space types listed in the level 1 table. + +The non-space type related data, contains all other data needed by OpenStudio-Standards, this includes constructions/materials tables, performance curves tables, minimum code required HVAC efficiency, system requirements, etc. + +## Space Type Data +### Space Type Names +The space type names list has been created using engineering judgment and the space type name list from the ASHRAE Standard 90.1 lighting building area and space-by-space tables. Space type names were either concatenated or simplified to be self-descriptive. +### Lighting +Lighting assumptions for each space type comes from actual building energy code requirements. As the space type names referenced in each version of ASHRAE Standard 90.1 changes from one version to another, a mapping effort was conducted to reconcile the requirements for each space type for all versions of the code. +### People density and Ventilation +The people density and ventilation data originate from values specified in ASHRAE Standard 62.1. Similarly to the lighting data, a mapping effort was conducted to reconcile the requirements for each space type for all versions of the code. While OpenStudio-Standards currently offers data for the 2004 version of 90.1 up to the 2019 version of 90.1, ventilation/people density values for some space type could not be found for all versions of 62.1. In this instance, if available, older values were used, all the way to 62.1-1999 when needed. +### Equipment +The equipment assumptions are based on a plug-load values derived from a project led at the Pacific Northwest National Laboratory (PNNL) named *Development of Building-Space-Specific Loads for Performance Rating Methods*. Plug-load for each space type were determined using a bottom-up approach, see the figure below. Minimum, maximum, average, and median equipment power density values are provided (average values are currently used when exporting the data to the JSON files used by OpenStudio-Standards). +![Equipment Power Density Determination Using Plug-Load Data](plug_loads_methodology.png "Equipment Power Density Determination Using Plug-Load Data") +### Schedules +The schedules used in the database were determined based on the PNNL led *Development of Building-Space-Specific Loads for Performance Rating Methods* project. The schedules were derived from the [SBEM-NCN database](https://www.ncm-pcdb.org.uk/sap/page.jsp?id=7), modifications were applied to make them perceived as more realistic such as reducing the occupancy fraction during the day (as space is very rarely fully occupied), or leave a very small fraction of the lights on at night. +## Quick Start Guide +### Create the Database ```python import sqlite3 -from applications.database_maintenance import create_openstudio_standards_database_from_csv +from applications.database_maintenance import create_openstudio_standards_database_from_json conn = sqlite3.connect('openstudio_standards.db') -create_openstudio_standards_database(conn) +create_openstudio_standards_database_from_json(conn) conn.close() - ``` -This code will generate an `openstudio_standards_database.sql` in the same file directory. +This code will generate an `openstudio_standards_database.sql` file in the same file directory. The database can be opened using a software such as [DB Browser for SQLite](https://sqlitebrowser.org/). +### Export the Database Data +```python +from applications.database_maintenance import export_openstudio_standards_database_to_json +conn = sqlite3.connect('openstudio_standards.db') +export_openstudio_standards_database_to_json(conn, save_dir='./database_files/') +``` +Assuming that `openstudio_standards.db` is a valid SQLite database name, the code above will export the content of the database tables to JSON files located in `./database_files/`. Because data tables are typically easier to read, parse, and modify in a spreadsheet format, the data tables can also be exported to CSV files. The code block below shows an example of how one can do so. +```python +from applications.database_maintenance import export_openstudio_standards_database_to_csv +conn = sqlite3.connect('openstudio_standards.db') +export_openstudio_standards_database_to_csv(conn, save_dir='./database_files/') +``` +### Modifying the Database +The database data can be updated by modifying the JSON files directly, or the exported CSV files and then be regenerated using the following code block. +```python +import sqlite3 +from applications.database_maintenance import create_openstudio_standards_database_from_csv -## How to contribute -1. Create a new branch -2. Write code -3. Run `pipenv run black .` -> format your code -4. Run `pipenv run pytest` -> make sure all unit test is passed (NOTE: you must run pytest under data-refactor folder) +conn = sqlite3.connect('openstudio_standards.db') +create_openstudio_standards_database_from_csv(conn) +conn.close() +``` +New tables can be added to the database, but they have to first be defined programmatically first. A new file should be created in `./database_tables`. Each file defines the "schema" of a table and how it relates to other tables. The content of the new file can be adapted from an existing file. A JSON or CSV file containing the initial data to populate the database should be added to `./database_files` and added to the `__init__.py` file located in `./database_tables`. -Push your changes. +### Logging +Logs can be generated when running some of the previously mentioned code by using the following lines first. +```python +import logging +logging.getLogger().setLevel(logging.INFO) +``` +### Generate OpenStudio-Standards Data +The following code block can be used to generate the non-space type related data needed by Openstudio-Standards to operate for several versions of ASHRAE Standard 90.1. The function will export the JSON files in the right directory. +```python +import sqlite3 +conn = sqlite3.connect('openstudio_standards.db') +from applications.create_openstudio_standards_json import create_openstudio_standards_data_json_ashrae_90_1 +for t in ["2004", "2007", "2010", "2013", "2016", "2019"]: + create_openstudio_standards_data_json_ashrae_90_1(conn=conn, version_90_1=t) +conn.close() +``` +The following code block can be used to generate the space type related data needed by Openstudio-Standards to operate for several versions of ASHRAE Standard 90.1. The function will export the JSON files in the right directory. +```python +import sqlite3 +conn = sqlite3.connect('openstudio_standards.db') +from applications.create_openstudio_standards_json import create_openstudio_standards_space_data_json_ashrae_90_1 +for t in ["2004", "2007", "2010", "2013", "2016", "2019"]: + create_openstudio_standards_space_data_json_ashrae_90_1(conn=conn, version_90_1=t) +conn.close() +``` +## Future Enhancements +- Add input validation to the functions used to generate/export the database and the OpenStudio-Standards data +- Add a command line interface to perform the generation/export/modification +- Add data for additional code versions +- Support queries to the database to avoid having to store two sets of JSON data files when running OpenStudio-Standards +- Move database to a different repository; Updates to the OpenStudio-Standards data would be made through automated PRs every time updates would be made to the data repository +## Contribute +### Code Formatting +Consistent code formatting is enforced by using the [Black Python code formatter](https://github.com/psf/black). Tests are run to make sure that any changes to the code is consistent with Black's formatting standards. Before creating a pull request and after installing Black, run `black -l 88 ./` to format all Python files within this directory. +### Tests +A small set of tests have been implemented, mostly to make sure that further edits to the data or database structure is valid, and that JSON and CSV files generated from the database include the same content. Tests are run using a GitHub action, see the workflow YAML file in `../../.github/workflow/openstudio_standards_database.yml`. diff --git a/data/openstudio_standards_data/database_structure.png b/data/openstudio_standards_data/database_structure.png new file mode 100644 index 0000000000000000000000000000000000000000..57260ffca3b0386bd74eacbf68a926781115e2f2 GIT binary patch literal 66178 zcmdSB2UJse*EbqM=UlIS2sQNU3^L7J!_ z5JD&k5J(hIlopT@AcTkrfg}VWB!Pq^_r&r(^E}_Y@148Wckj1u)^Z7loOAYn|9AQA z-`?lkwmWStFS|t+1Omw)Klb|>5J(0C0$5gZozW=z@`TzWvfB!;;)uYi;(brq} zO9e~1p{ND|T|BTBvqE}wrS#~H_gh<}dvjy$*P}b)q+bDne*Jp%(YpT~C$>ciXK-?I zpwC+Wx>Nq6_&%hdH?MMjGCOEeB}R z*TBiCWOgHMB(h2P93~c$4Qg$5X`j0A9>na!^PX6B^YBBw);PQYWJ0`@=t_m=a?(tg zS&$*Hyb;z{_WMG%uJZ)!a5QpUK0-u2xU<1={T?L0f6Yi6O!JXjMn#P*mw=e5f!339 z`F6B9_{XuLs$dEfD{$iwH!mcud2#Q%dcMT1PzJqHkIzRp^0M%gJP~~M0a!dBVmH$e z`RGNGt25>@)I3~9_9+apq|Be24Pcm*8%o$|F(NLRo?411iNHqtF_(x!MnV}sd{gME zUg<(N9RoWc@Z6y#1!Kwe*WqTbK%lhd@^l9fC`9QgLBJ?wGblW6qirCqjxsaEPom%@ zHzR`BjX(!l1z8RkZ8)sgr3T5CE$A?999Ti3!4xa zHKBkEmbA*@9cf|RqPbM$=UOiYU;!61bl<^*bLC5N+~+vcftVMR&M>$I`+ZSv_!^(}bs=c# z2gBKUzXl?QdT@Cz743tB&r za075omBE@1vY?Bn?UO{Tkk(3}JT-M%d=d&1j)SQjBJy>oY4l)DwSR#jHle9IZIgHN zIcj^$`UbD^-huOBaPNUapU_yz7eL{QbE;L)O%3`ndtu1&dxQ!7^*p&M5^@1A2P3>B zpF&fO8b7x81*l`liI)MV>5k&*oy{|f;Vj1sIbRtVQd~nnN%G5^15L&{EV}EEG0RD?;KbQgJD~Wh%Z_Xu{|N#) z11JZ5J7EiE95JC2Q>jUD*)ekT9k!G{VlbW0unAkrP4MGss1cv&eKZj2`xS4d6^Hmn$-$eLH6f7HHzY5hN^4NWJ$`@4|>$P{aNB;;4e> zjB9Le2+Z`Qo_+)8b>YymY>=LKVg>*Ggj{p>C8lXmsc@+=)u*v_O?~{WoQqH=gME*If*Uu9j$AIEehdy!2a$Sfz5p0&&_Y`|g z1T8Fh~El9KM@qpICr~+&K3(_ z+{5R-$L8Q-o%Ct1cc$dowfe(+igsTBW6>p5yt82+uJ4Iz{=H;8V*G+BFY zgUr({qvl%Az^6(^5VUP@FHb-B_2-@&OQ|%5ac37p_UI1@yJRKg4J-Tzs?!vRkg=JdqTO41^Jb#cv7wThK&dcdXtu`JO)wPd#HZm5%zw zveNy+@n~4X5S(jW#XKBPpnH-OwKbbpldjN}VZ&C-H2oaTGRcZ3l=Q|nUS|5YJM|ET z5DBE|M^mW^h_oD(b}_vuBZw8FF)Hbd=jL4RdcjIQf+m&{-KY&>%#!=08N}fj;A~)(q~2}UbTk$+A_7? zGSzG{MIHV@19>g*@JwOKc;!izgh@O53Ncft*~KV?j~omt6NW0W%a0w|Iv31lEq{{k)zY$G8IW22cm4DVUh^JcG0+nwh}R7Ja=dYe2rwvzhH10*W`|xWxxVvv-!+YEQvpP{%2;< zb#{$we z3VY;6uBsB2gn74K3>O)EZp~M8Ws)0n7>HQjCNP{aP0;IWV7+jw5-vY6F*8A@41vX8 zu402q9%M8IwKgsG?}0UZH0Qs&xjACtebESJ2!0l_5Ir?_GcIw&5IF)>x|4E$zz1#V zZqnmdIxZR)eU^Xwv z^_ZHL!Huru&7RDr7%^%6XEEN%NuTtb7_IMmIjx47r(SOcLB8)y6bwA4NhbafD>%fR zsBQQRPmP3SDw)8E;?A5mp7f}9^fTX7N>L8Oh#`cm7nFxS^CSzW7w}7+3$Debv3!7 zthI^}d$z)tZ*OB)(RD{G5g%y=^_lKj_{6?is%(r%0H0i=R+-xYK%w|De&x!GGDRhE zlkmwQAF2(JdI(Bv8zQqhn!GzR4M*N%=y?&yC#ck1$DXtu$VhJgkQe8~fShY@Xh#B- zJY9TMQwNMFm^_bTmk4*0!{Z-1hvpmxE2r3h4=v?_D}ZM3@XN zGiILUR~Ag29ZL-bikqnhCoSwGWc*G%rlxEPR%a&2kspFpNqE{j6MCY?Fuucj$cWFk zmIB}iILcJ;`Q*^`JrO}{$*)Q}MGD644gv4m=v_?kxQ!Ks!+Z+=71)$~bxBsqO3!u^^qhk6EeBWlv+$nX|(W;t8@TqL_p6?`2>jLGnp;FNnQqj1s%^oJ21EOTvuvlz(F( zy&Xv32$?#D6)FbeI{9!msBL8^>Z}$o9k&1`9z;hP$z7~z;8`-O>_#<{5qcpoAO2hM zwGRhe9GG9GF^mOFl}f_N!`vnt_RFF}tafmf-7w9z|D;xBLfYYg{-$8f=p5zKev~Ng zxuC_z*5LM(BKai`;dYm!l-|KXNhr^vkr@2iGK7nrDJ4{)=b%sO>}Wx5*h4Wkp|PT{ zU%vucy`xDexzR%rW(LHDJK~ZUQGh~Sr$RusUN+W0geHC;2Oq;EtQl(HFKyJ#l6@v& zm&$=JR(GV9)1IK32O@;^sG&?hCnIqcO|#4F)zq&I{O%BEg&Cw7-#p^YFp6C;qd>|; zRe85#HQ2lu+-0z=zgiw7$Zx>!HRDgd)*n((5*v=H{=PGna5~$+6#i$3HeiBddel+7ZikDhvd@#Ep%2oMmg%a&ul37%c}o@MC2?&KpuK z#WuEqMbPqnM| zGhO)+TgIImn?(5z6Of{ycf7gRRFXI3K@9>$A`s-Q;(7e@=~y!e-~DRMzm;OrQF$3f1D8bmoo@H>s8h9zBk9bOxB zY@;-`ly3249w<>z7ks(c&OB+RbRY;B>B#dq1-o3J;G-}*Jgzy6ZFZ}FfmE;1Ll5S< zP0chXAfSAKc#f(oT6(cJcC^MP2&)S}{x)Su0q#PZAjbN#Y41}yMcyzgNmGsFew?$0 zexBJT1`NNx%QPz;UPYQ2tfAzD^f$qtDo2;DxiJ&LPFyQRO4o`Y58KH3C(AC4D4=Cs2vKaK=Vw%rF^!p_VF%5;%OMxhOFDm=9NLY!C38a8Oz^tC&WyJ_F(hZL>+Bm^6OBt)7c z(*hP zuAC792056j78tWjE{hw#Meyqe(RnA>NC9yxIGPo#vPTc%Q?RDG$;<6r*xb3EO;^M? zC!{!0trE1{)2c}#oU>$pNQ8*mAHG%UH9W>tE97q9Cg2~AA7mWLzt*goLmk~{o!4Oz zVABhm=X#t%PB@AXoL5cp7v2y+mfUwjMRTCSK4K<`{t<@$q!Jh2CJsREMjJw}eLl`_ z)K-n&Ryu+c`Koy8jubW+xlHejpO$iwW~ z*Kb?{L0$-?77jON%C{B>Usf}{c1!6=)wWhmWD}|ZBgsYw z#eAF_TADOFGHtnz#eT+p z6sa~E_Kc2^>wts!3jdh&fxT(zb!mTCtAK=i=AvbN6BfB`mhTy&=68fwL$Zkg4EBeA;2oqLc5i-}G&mQmA592oLq^t-~a)-#Oo=4a8es>T7@4)#5PiZeE@% zw;eJB&z|vnm$0$NXb{^$EFb(3G3(9utq(f4PuRp-mL2DU@v`*(gB02eg37Ebzz(Z1(=lX=iZc55+vB_WXNTr} z+(chk^Q~2R1~xRc=k63nqs=XGq8$4C-|v_AS=(?{x@N{N%NsY7R!J{*Dj! zD^_ql>K(XTO|C?4z_Yu=H)7c6mL+7*z?!wfeH%Z7%8(`3&5?GH;;A@|uYBJPCqPY2 zF$z7lRK1thGbkc+_6ln5Uca0(r#K|l;u!SE`TR181y>SMQ_&IFJbTk50!9XVYM*i_ zE?Yt&j)wJNmxZs8E`{&_<9c?UTJj0Z5sizEPfjZ_UOW`L39PW~sGA+r? zA!RI)!2$0F3ccF~4yI~Y%6#$>U-B@@LK=m5srU;i4dN7tGvp5Aw!Rcfnd0qIH+qsp zHOtRga)$oS@a%UfKx7(mtE;zvcRCk*b%JIvRL`1rFt&d6}&wlXzaq(2oI+I5IRUv(k=Kb4rtasj6nD$R z2-t?vm`5zcmGG>D!wb#U>Dgpx232)8U`CA|!c(-tA;I8 zv!VUrN)P>rl4+LM*x4C-wcQ_oHg##9Pd>Ivs`Pfbr`GZquAUvXEPCz3pD~WKLkEd> z+a_~Ty;oq(SR*wB$W#8JbRx^jA!N$3De*GYe`sE^*eD;^KA(>Z#_q8A-hC<@5IS6g!kq$q%*LIz?-qM?ty8Rh35=iM&!Ih-c zDzx$bO^%OHVQ>p(wp-BRvJbLizZ&900vKaAl4pIhac1057aqx*YZB$%u?Q9t3M=_x z!(GV$IzmB z^cqDn6yyb;+5w13TceFb(efGxh8^|gexS;yLQ#I=E4WGS-iBRQa|FSh=gBH&9aG6W z7tk;Pv-S^vQOpC0*2ija5GiA`0~mvRUFm(^VWeWa9Euwc7M#SHU7VJ))qnQBFi}Vh zzV)@^aO6}JUwN!CQBUrs&nz+*!E@%5=sG{;*IR#x9I7X`{ow{Dci%4z>?h&4_n?rn zSb6Ysjc);Qn!D|Go^t)7FNGrg?6%p-=0Z=!8s-7nYpMjio-b*3F~+ zh@J=|@5c8&nf<{#>suQpGc?$uQPn-`_rQ#hg|0+zVoW#>p|2KwDIAX#mGJXIgo3N# zBh6mrLUy4oBwe&(n}5hRzwdn$Jfi3d-m#F$ScBD^!W$tb8xmz>PWwHk7@GDN63rH; z&MDPv>UN-osB4?wLFbFa;Q#O1+?w@QZA@{nb#hK+mbM6TmRr5XW!Ld{;%s%vtQ!4Q|ZU1hD+@DrgMo|=-THBf< z9$!OEB#Mr}YD;K`X0oB9pV>pT6bNr|Bb%?+u#Z;idJY=@*@aYch%(}XsL*1*_h-Ii z=nEH`mRwXe`KcL)3+8`sTup0?tpaF0O{1|?*>viC!9w#g_0;&RZB?>$LD_{$OZPRKc9zn2|0|3UGPA48|X-f^t zx+W3%$szj(5?8{LtIdk1JWCXe1rE$?L@(6+kvL!`lW6h*ryEbEOZ+`d4IpSatZv87 zJWRzsg(r1AGl!pD>zy=X4ORNM^@1;!Dt>LcCLQOiFe(Zqt04V+Yzh5~;jp5Zn zgqrU)q1P|&pkSLEM20B#z3PSl?RA(;QRGPj^qq{eNANK;1kNYCQFwWlwjL5~#EgBG zVqvB6s8Y~rRuooBo|961Jh!km2F{U7$+PJtT!9@5GFXp|xZn?w4LJ|y_Bm)&YxY}1 zYu5Kq1O2e~(WQPG4m(ACgM-FLU3mB74h|t#x~9#Z-Ivp8B6QikjvP&Al!(mIG`!@= z1%jjj6xou0uRgQGJua>a{d(D~D?MHS$a75PNenRXv&6s6z-c6pkzv7J>bldNjwOEN(0|xy;OeIlQ@i<6E1vOYb6ZwYHtQ zMZcI85$j>sdIwk*lD6eYpP)KbSoCgTKCd6F)A#-kp`*|jjx+lb$;-+GB!hmk zuSvC@sjlK)5xcZBylV~3<6DDQ@c~;$X)gn69)>PdJZBluAda5ni+$_aC;P@7Z$2{? z?Rru(wsU!6!Knb1aK9p|A7jlo5WLKNBTH0P^jnmZp^eRZB%$UoHFqb;AthA<++~(= z81$LI4|ym0Pc=vp$bo;40eTK{gmlvxFQN%)HoYNP)_mtEX0N`?Y(1^YtGNCW^Jm5- ze#nl}W>z%UdW8mfCKIdLwKMvO28j$Kt%P;@QM#}7RRl!tZ&`5=4a?@XXd{J8ALr;lj%(z>+X^EO9EVdJ_ z6Fy(I9Bj1rYZo|yqS+?SLJ{>TYmAiLs=2C+96Y}keL=s$9Vtv-Gjf>hpWV0%D8ABN zz`lLGA34yynynpeWZhAH*UWfh=BfnvvF0%A@zg zJDbLFK-#d#Qb`yTxbdS@Y8hf5L}S$(#(sZr%Vh5X4)c*48b+*SR)smi{WY2ypMz+5 zhN&p8Km@wW607wF{dxogt}ff_9}x*j_RYpCm>rb3luRXSDmO8c!9AzGwOfzISJLWP zEkXA*&-FcUMk)`yIghkKu^}10qz#3+A{5p~5AY`j{T)CX$kNuPD5SVH3!) zq*NkH&p4s-om72#WL#9;xCgp3bpw%+nZjvQcGZz#Sl%B@0LfY!gb!;FDY>GU9I=&+ zSLaLjEp(f97q{j8@Abt`2wNw7A_7AIHY`kXeRL$crmI0w=tCTZ5?Qu|AV!mRj$-xt8$f~VHpUmV}1 zTn5hWjuMb{W!`Qfc(o7A1UARHR?dISKn3<%QcmxZ&BM(MKE7A;0x7H{?qkyG^~;jp zN`^5Z5e6`9M@F4@nXg*3JLI|YMJB9dufBo6O|rfSnHRl)X{B~iW2hMcCY8o7FEO*+ zQU_`RTAPP9`O2cI<_0g5pCf0_beHXK)f}zanH|Kjtm2T$Ehhk~4v(s8hcx)%fWAx+ z4?j7ClN{mc!G^*8=HS6+~Z<<#C?u(B1PBaTn%J$+y+K>C(LifYrn zOzu33$y4w#Gm^N7Iduw`VZS}Tw{bLEq0>^@?pVlllBtn>$Ok{VhUc+DOd@965tGXB zr3AvJ&p-peGPzLqPnE^1%NUwOEEDk=;Prv_%;ka#iMI-XY|$&1N*@N2cz9aCq@5REgXi-3@JL$FK)PETy-Mkgjcv8UU)vfBHVaFcOjmzEeC+ypVn2D4nez2(g%B{i9f|zquHKFBg-?gX1T0TIG z(B4%*sdvOy<%r}8J9%e~3pgOavHn^yHC%5IN zT;F;f6GKvy7p;jS*RC8O2fCqKrFL0cdP7Kx@uI1yqiX0&+8%*h?}B=kIsfGr1!0|6 zYo+A30pwODG_!x{WOLwkFvTBmRK@Oi)T!NmPrO&ZtSo=T1$;sTux|NveRIboIi;`8 zS`q!WWLf2)`VL+ z&;OyRq5tpal>YsWkM723nofz)M2S}XpP{e6k9-~Z3DEYw&9??0?oc}QectP<{vLQ} z@#rK%ouSOJHCo}2uftT|My#YmRL|}z;x&OYfsf(}K1k9w}d$_@q{C$=S1bY8#%h9&A z7^ai}m42iHY}>qV4RWR3GU?}t4why1Nh|>CZGO4jZ>`s5(S(%Tlnco#vhz&u)vK=} zpK1S>Xduwl0!4}iRCarfMN*E`C%=CBnk-nUu`|(p76)y&>-a+^q9$F@AbZ|^nkezibdpiplO-Ub@qU(Y==)(i!Qw@Oy2i)a|v zXxt3~wMZxTn*VZ#&?W(wS*7SI1G;e>P|S_7?{~SjQz2hDMZ;t=Ll4Ft<(5Zuu1RNH z!(V#;3+`%v32Vtbu#xM43!OfLi=6wkG;zMVVZh|z!QSkHdEEK)n+?#uxesj34!aUF zY~qPvkGWKz$M93~z$Rb(ARV|e0<0rR(F8v7ewDAO3|iJn^y<)F*{7UcchB$3#@&Tg zi~CC*`5DId!D$S>$MRA#!$2OYgBaG@L*34T~;h2uH`ISn#j5X<`{4Wool9v)3iFX9%E&W<-SW9 z@*Ach{2yE}1lVY)6l-VGN}w^bOU{(vS^^c=pI7K-flsCUvbZM+JCOjNE}To$`8i!4 z2{$0pr_A{@pP<~$J3EirpbXqV! z3EmEj0*MKJuye~{ceg~RRDxw=0^H;AW>EDm?UF*GUg535=E?K#DM3iuGWoz>+2rP} zu3??oWIfpu%d0zi(Njh4U}&U5b8HW$n$8s@w14hb0Hv+|PYKQ{POZVoij_Rq%L@EQ z?W2QA6VW=Vs~ZY$5ifTy%j$AR@&(QnFY`Q#%a5EVP1oKc$sb@KltlZFq$-;-!@l6q zUcTsb@F_K<&?@v)HA%Kgr07JX?C&wK5Z9mAN6!=v-_bajzV9J9cG%H|pPJ0;gz2t( zK66+@fe5*J7%6-kdKE@HgT)d|7o$TXy-5#l>u&hl&&h^X4ztxmMrt-+&(R&aNN$MVxn0fWOgwR>0qHzT8mp%bQ96! z3iAF-Xy?ad4N#i2B>L-SIM~1Qd0n6!Pw`N2jwyesg_S4UE4{rVe{%ncSEdYv6Qq@T z)VDjtduZN6)Ls^27bG;lAxi{Q5+ju=4Ru z!)u7{h}5MtqR2x@aFr^%AmUQK-j|~A=XriwlQ;J_N28gbs^Xp4NgVxL^@Y*sH$gCQ zeX}R$VH6w$;!1(+p<5Bhl(oWzK$Yx!i1~Br)3k10>y?dh2nSb~b zHAUGS4_8#@%ETdFO|3~lq&c-H9I5ethcsJfo4hUy z>9p%A$#2)aN5BH*ytuveM2g3&y4JIc|b>YBtR2djD_nk`rUW5 z@P-~uiZL9fwVofycgKI43#a)iv~M9sj!Dn&wj&KS$ZCk(-@H}W+We*ZUH+1el8&s6 zNOWg&WCm3M8F|;d+4J+}zVShtxB_H~Mi{GDk%aB*A4A<^+P91dzRIk) zX#afIK24SK$<6x2_?BU8Krc9B+q$uS?I8tn&0R)$a7}Sn)aseUfx;Q5i=}_6t`;)a z#-N1g+b7=5UI}0h=o58$v6~hci;L*?Y8MBrA?;od?3dw65q;nslCWJg2lt@Vd~p zpbQ+lUfacSQ_6`=X)4Ol-*8t7%Sd^SD|{Z;3(cqYdGjqP@~f`q#S``zUyk+<<66>8 z#gz{For~sZ3vYw2sQF|oCuXTuTR40B45;S47XjLjyBG!q7SvF<(5^X}Q^VO2o* z2VMD3!`F{*l07ThdiKp9Z=YU!0GF)|&_LJ~b9e7OH%qR_ME~)2pB*n#XAe-m+rKLd z5SYJYeA3e^!T)gY) zxakpda1ot3*(1K{ENnhnJFD`$E2s>+VIasZrbkd+)_)Ru-qyxZq_0y}gnj9~jGZRe zBhf)+5JN%3X?!e@Vyyx`p`vFoS)+auXbEhZ{7T{`E)d z?d23(f!+zV^*!R!0kLJDgfxonMz)tcyP=4OOEdKM;eNNX5s^hVoN{i*iX$eAZ_&^wdYuT-Zz5P>=id4l2CNGcaslg zV5|2)@3~upkA4Gu1o%kHgCpcVjZt9eqoTVn`eNb=Y)_?Fu(t)fZ&)GgXH4R@mbbtC z0CqkX2skw82&G?RbRvE*&caJBy}7{rZv24CE{aztdS>w^tKy3@hZ#joBA(vul1h96 zC1T*`H!CS6QVwQKCN72hm)%;PdFk6|hN2IBAf2w=>Wyt4s1qoJki;3Ach~0+Oblowc0GTDt%He$UJ5%i4bE@SF z1C~-zU19_7U|y?5kcIy#*>7kZ1Ul*v5$ULO!Y^y(Ib~>vL%#8@mi4Ou?Qk;{n(3zF zw+4rc8a_I51_??t5xK!JZ(*<=Q%_R-IqOoNo_Vop@6m65{Z+_K&eSn##XiRsCEx+Z zT>etC=35UVKawBZWATX((A;M{arB2)m)US)p!D6ck3`(tDakM5TU&WrXs07?3&vAX z**?Q-F_gq_Pa}Xp+e%Fuw0pM=DU@?8ykVObCuLp@zj$GDphZ`0dAM?qOHeM*@5OMP zjm%h&e%1;n)|2AOzi}rZ&{vJMB@C)ObD45gTDa+)<9GeUSC*lU%{|%ipK4e7(l#|ztRa>J+M5ckFhfjTH5!jrrTkA zcv3)W0P!xbKVuG=*{}p3<3yKv0*!f2YGO(}_?e%(1hd#)tUG4Fiu}dX>&!PZ27&ff z8aJ89MWGg(=;!vT^PJOInGF>+yING@>!WppM3 zDEgO5QOzek?J6ZR61-q1F<1Gs8b}6+j01qvNjc>X2 z9j|>mDjWadkCmV!)Y{cwgWX1*uN8|O)GW1VoRHHhkOft1khea&^TUO1tRCk?8h@`- zd`-&Df8=D~*79%ZbD=W>`zrs?Ylg>{pJ=0jL5r5knW6@T&Qj6?>{lR-ybLmrO*P< z-Ilwg@vqeD4qJ%CWftcd<{me1;UrTo`}mCo3~JOR_W&N%?wd0p1mHtK`6Mpj4v@dF zcfqohXb!{Ub;Jhf1qCvS-m=m^k1@Ssru!F5hO^%!xweY=!tc^pQhY1ODl?kB_l26 zK9Lm1vnMHYJ9w-3JHA81zvw&wF#hz0efTcFv_JYiZk9H=Kn$X^P@=RlMwhsW<*w>TThl-AY5)HwM%bPmA2EB{tSSBGZw$xhPW&kM30< z8wVv%SNlh9^h3M!f;;7+18U{t8{-nFY35_s?UU3`gU{*7VG`w6{8{8H6xUa~5goBk zPHrveS);M&vx;Bq9YC(`i?N!v)|4USX?<1#aA7ugCZqu?tZy@hD%^tHP+78(}ADitpfU2FFuUirUinl_cq5QRCcnoo`n55_VU1K z`noMC-kh$Tm0bAzLLT=8sIatDM2_dI+kLe+N+kxCV#e{r5+uCo_UN-W=BlSnnZE*; zRP^*x2Uc<7b(no*!1q9BnPgL&Aj`Na2^%xDyfYk{`({+t!oTIi3r<-wAiH_ey=&bL z-Ip%JrG10{J1$ttgw;sugLAd40*pzXvp_f8^Ga{jfK>wm@Y}aWzS_PA{wwTlEHC(@ zei-RyL`r*VkmG~l1A}dte-}r8^M8fapUHOSZZkyPCqBpQv%9JWg%(NooB)x+HlSg~ zYcc!R56foV^;7(goNxIR=a=(fs$B=472D9AS#YhEqk937>XXQN8n*^FtqG8^d3$K> z_hPN-&^bFtAzF^U`Apvn&R!lt(Q{h{Ad*`PGZTo6cL7cB_*YIC+p?$l-xRtQv*9El zlI|z&Nr1L{Ywl|P;F`Qe$=B4J9W1Zh*Dq!^MI|WJOq(V*>fIVldJc%BIwyEO{>)oV zC~F5WIR8v^1z!UT|9_?va5umR|1)Jn^M}@Adj8oi9swBc!uS8kJZ@YDh_@e#D7vP_ z1K6pgGkv>i%&3cWh;6~c-QP^b9&il6R`R^)7Z5>!T`t^DuOpq^<^5fytFnNnEr0A) z-rM*=r4x6a>&)}+SsZ^}Z9a;y-?dv=eF2Om0p z*Zqplqe=JvYg4^E4?5`m$F6SL_`@3irJ$1IiGx8z5jKX?i5p=CE#Kzk@3=MiKN#D; zcI@hiq7WI&ljTo2}t8yY|_ApJfB*!6$9Qex9FqBKl? zbz|vuQgg!N@JzAwh=`&YLg8tK3Bm9I4aB?*e*u#@GM5PpLB@(YKQMp4@IS8n-`p%~ z;n83*&}jId1o?mFIsmIZo{!4^XQuf7t4MWwv!^R{*TZvicdp(2XM#UJDf7nY=syUs z-oI#t?_C%6hm$9+)8Nyl=YLhAiYHXuCl^THW?RQq(728h1)_m@It}(6SYWuSTLjUB z4v-Jdnc{(*s5vToygl&Ur?gcui*%JkG4bMek5+;I{$Hy6S7Pe%7AGW%1EUgJ9sCYU9v}b(N`6mT%oV8j4Q*?8E;`H~otS8xbX7+nyZ`-^r?Z+n?D&flNwYX=DOay zSt9kC4q}2sMl53|dm)(}YB-8%o-tcI6}0=J05BTNNwqMe4Hm4)=}%Dx$6PJ^)rPI< zmp1-@yFXU)13MmyBP7k$yJG9kc3n6q$#PyoipQ*noXBKqWk2NlV%_L3N21qaTopZC zyDz`VBksD@F84@hs`8ih&?8Ckr_zd{J~CJS%#Ic;r%&&4_hEl}Hiq*?&tvMsp_ags zAC<)S_`3ExWX=!0;?F#Z;N=Uu9TCP7W9Oy8D~7eorQmn$p_?y?pIjaMdEXTbt~W!` zwIJgTW^2dFsiz;EnG2Sc4Hc(TMX&BE3V)a4)zCRpwM$M(0rXplEpm5fM)t_&9!kwA zilW!&6pEJ&0+UeOyHywV{HT?_hvIENAohn!Z~g{;b151Bz${{7*{^UODQUK1!;rzH zcyFpZ|8tcdZ*p}O5Jg^Vg>U*jJGdT!tLWI(U1?Xk>&g0}jh=bM0H)29+RT)?y_)V* zdQ-^B<>@H;%N$C$u5x_u*upgnf4TnlT-^6+?_WFo1CVDCP%$a>voK7TsB?E_CsA|H ztoZYGc1QATINv|(T2P}XJSZ@~ZY@Sl-BY{cOtG?T^JO{A-T3x_82#AML0*8F1#4qJ zP}6*P!|_iu*9wnBEG}0Zo;B@0>_cbgbAB^z1$xM+6qRDb^FJ!J?@8t-ec*{+pw{UQ zWerN6naq~Z>WIRQ2@dcE3du5En<@=q*%A9stsPEO#E${Ipxz!814=Xt6W{aJg7wrQ z$*t_i@`3U6+Klf4lB&!@%awA} z!V#0)mi0q*g&|EDy|V|}q7DF$BZie!oBww!y)=VdaK>Hdu3|%Awb5dy(!EQ4wj+l# zsZ7mb_%p+u-H2O*^6N2&s0z)idm2M$1 zyYBzNAcT~)1K{~V$%Q6C8hzI8bGjoef^Qnx zol`f@_V-mZ3ID5iU3F}QZUx$k0O7E&%x#Yyo{`eb21o!ZZ&ho|*&@p@r#fEutF(LH zxf-E5Fm96qup$5qEqpYI?XmTE2D@=U%A(*`zg%urK)qv&`tXZ9u5e`Bwy`_AG#hw- zOaKm;N2aDC1UH0>m1=^N^tR)9_yZ;mjQjG^ITI<_(Wfi2>kRZfvzA<@Yo(?3gZDTL z3?l(gV0qrA8d&e|3@FTVTUGY0HgsIRUL~AY2n<7-2%X!?tr1IlVAzBiH^}d+DG!V^ z_Cl85on`lvN2heCx;Ke0=wXs$UZPf6zO0U|t1y8Aj6fAIcs(1d=jd*hqG~> zzymu<@oh1L;2I%26*pU^Xl-A>>9XYX6i zUKI-#VD1}EvapBmTnSVYHSuHf*A2_oPtM?SVm^NfVFP`z&gg)=aPbU#8w@`x>TlJ} zCB9HjhsKbW*ifW@x^OnHt|=#$5yswF#m{1JQ8$*$P9m7PwUY#YBZc@b0L|H|+@N6* zdHAJV>QL~G(jZC(HHRL(j4kf<3GcPQAf-8Jie|7C2Sfp^l7Z3iEh`CK7^%9 zjPZ>Mu}k%Pe{-C@de0lBS7sXencq0PvKV+E9N;J3`DI#Zx!xJeiYF)hcW$WHuv+RC zH|7^6ZWEDn=lLyXTdBD~Zkcqmt&K70taTlj2{RlaG`sNtbNIt=06*(KpIw&7e@S0% zgU>WjMhtZudZiJf49DZ6YyU6yzC0ev_I-P*M~W`+ihaOxbJEOhpjlUw*JIkH%OZO*_s402J0RyJ?Xuamxd zUgR=kr92n&NFs`(;iy!?|)?5pAWLXF3|r1bU13o zs@pYKm!-9Eo_~8FHi>Dt6LgV!64k@H$J*1q^qO7QLAwB4J0QfTIrWX8`jb-vFcN@Rw?Kd|8xIl0R7eJ@DFt@HCU;-E+k4!? zl8cJA9z_xB{cP7Fl{l|Orhx!G5jLsW$LCpQ3G0)WCH5bg+8 z#fu@Rw~pPP#R0YQ+n)#Z-?QjuEoQQC=2sohtLlxC490PpmkXXd0brF}5+yk@qux7C zRRo@a&;p?|93%x)j2c3vA07HHFmzhLA~|1Nu#gNBWW?I zDt>lcdZS!W_LKa+O7D+Wm1v`n@N(rylvgwrynoi=X*1!dgBM@+4}}%DPX*)VpFei# ze2|}|LQIXg)^s!j+V$p3)XDy(1SHupe&wP8Q1{zo1eDTqG4}X&h1z{}E^#HK$mQrW zv<>+*NGl4dG5*&V{Stgk-Qszi9&V7{jFV^S-6ihHuMJjP9xB6#OYi;)v{HgLGDgkf zlmb=sdKJXQbC*Yw18=8Aq3z3DygkWDgDakM&(~IDXnWW|tnUguXO^9cRhT*v19%^z ztDY%+VI7DSYs$^GWRj67#VxSTu58+SzjG;apH}N_jI#SAdHBIZSi`Z9*eDCr(2j(g z^UOn)GAo zBojPP#|}{og$v}9x!CT|zRA!oOWfpK34ic#TwGI3oF>tDXVZ~%D_v;CXjyiqb)z~o z-f%c^G$E0K8TcBnCzk~i^AbmtOgpL2{C}ozWqx74WY|s!~pzr47HxR zc%o@M-w=(lZLPp?V;-tZD4q-sYAG>^DzDEbUeh7(T1c=nwZWBrjg?QBzD*3QvFf(k zD{1S9cfXLw51lVC*7#2cb!Q+>!y;Uj_hlck;#CRjnaE1Zer;~%LG+!B6#boOFf%Sg zX;mT2Pol+Dk=gxzXlQu}U8g8!!afbu$mDV99BmhakTaKGt7_I#fQggVobgE z)hZqiYgB<_vzGzo;&B?NMK0tk`NmpDzD6adEY?){If`K>R5sGVpTpvM&xq#jw2xO| zSnIaRQR29Smfk%L)Ur7B`t1kRmn!cb&0tStN`IYQYU-R)im@R(WlVB9+Q-)hTvuYO z&@h!;Up~dA6)et-m@N?mj@h)yYgFfQXk)rdaaV-7)J)S}v}fq9uBe>trG|^(F{_wb z{<_4Q-rN#;Hg7hn)nbq-SM4cAL|Fc0gYA17jorNMB1&V6R2@OgI~lf>cMUzWO^{9_ zy2(%SrRR!uWlcgN>HdLTJ*r5pElv7?=c+=r=g@wN`!g38Bc^Y`EObj$X1?3}(14*C6x`C>ahjIsfjd8d^rWU z+Pd%Me_B9I1~kX4(GG+-`>a17)L^C(>!QRMAijSOWAw_PIAnIXHOB`kQ$93f47n84 zjuO6_gB)zIs!I!~dE3X5u6=7I?>>y^D{msS3p-{2>aDuG#@y`iGiG=u{5>D63gH6mPyep??Z zaP913$rIh3m6=;U73U&N~|OZG$@F4ZLS@M0KL^=Sy=Nz6(XXfT;3C zgqiiZDCHkfq#wVWD+d_0c!BD*%CN`M!t?%yzDh6_Fh*k0jTlG_#Mdh}ReFZvj?|^c zqlw2dqS_7d3{B-H`%j9_7loj*MwSjx<1J{Y{+tzm3lp`;&*;XMoA-GsKHPz>)3G}y zeBoNO%9dvWmIarnu@-TnN$8_rmmE4<`D-w)b+gU+Z$T`EwfJupC}7OQBufl;{+TaP z#XlD;tUA8A*tx%&8sNpGuiXS_21AdjMr$ za2~gv^qCzXNcMG}a%T~Y=&+zY08sj$e+|x_nc(wFyZK*M=QqeEz!H8eb^7>X;wHsT z0ZqrZr0JKw_fOvA6sS%9|9||E7V!Vd@=zKJZ#$cBsilfqHp^Y$QGV?0|77&Z(x0TL z3=CS%`Wphn|FK2=kf+jW?*Hi}en=mG*R}%w%CO+}(v1SUmILxsQOPIRZ?e|kw1URR zqPZ=z%t{p)!%4^JtkuR3oquwbxbzyfS-!6S@SXli&*{%AqzHiAT*>*j!{Y8{z0T)) zkHzd)+^oyjJrKxyV?G7=0g2JSEMa@N;`0!Rs9GO=j-SKaF5B;tsrdI}>qX9Qj$S&i ze3ceLIW2Spo7h-hs=B9kQQQD%sD8uZFvJeAdV!Ln^R~gt66yIlJIXTYa6NB?HLAHw z9$>Zo>ea@QmwsMLYU+1p@4vrF7Z@4l8Q4@^VbAy?%+Hqb35?s_!3R1O=?v8hL6BJ^ z9`;=QFQ3S58LW~wlMLtPn@=;if_QgB_c))H6yS!>qw+-F{!(1gv_kirEP-t6w`+~q zh2}U-F3pB<%Q^6uN9B_`I<$Aj%VWG_vK&MBJ{3_&GNzl*z1w3tIm8uh)z#{9ddkQS^)fgpUS^ra{ql+b2`Q{yPJy1}x!G>3vk5Dla|0V*EiI zqt`iyy}qDxqL@|I6_<2O$ldLGY5Sj6AGB8_ZZ(Se?BAzk*fwB%H!n_#;r)cCm_>>y z==!AHjM;?p*5e--4E3|*F4JvobsN`^l6FFsXtKGhZPx22HUGXdLP5AQdOvSwk%l0~ zv{?928-t*G(Z3z#?-1YmF;c-Ag;4&=GM$R^Ugcmobniw_7RF}cZ&pQs&Hjen@|!>o zq+nI6Rq{^buq{bbNqv)zU5Eaw-v^AVb&cO|ZTd$baNXgUs)dBJ@3u^i{B58AHwm6A z5Zi4?1Apfze#G?Fog!f8H4JA&i#%dK{{z499I8q+1d99g`uwoJO}X%$Ox1+^j)7bRtvCDnqy$yk z*!%LG#T?8 zJoVl(UE$P6av$(nZRf-RI%4cR`XDJa!>qJO-dcv?ugd+;fk1Y{4?w^kzWg}Ob2{Ob z31HH_JVK@5KYfnF-c%ib2gaqNhp9-CUTqyC+Dfm7{r*eyjdMUv&8YbJAnDF)oh0Ml zrMNekvmrfHeHLW@GU++1SGEd(jR@EMEhRKVpnO059+lY!hPV)OfAc3Pnr_Esg2O!! z?^)6-hcgzNmY~I8?zpVuJ!RkHUqkwG@j-`nhDqpwkxi|XrAo>kn3SFX<09%6ds59h ze!oQ@nASJa8TErge4vM`_#KTx_>`Qt5JtL*Qg9nYH6q-rA}^ee*YFXNFXufT0jyojCvzE5A3p!1&|h8vy8}x^Ed^b5@9|lZ zTZw)nCDyMmNFy|MqAN$EZC=|^S^+nPS_*I10V(gq!gj9fJ;?hM1bfq=y zF)QA#C~iS*#eO3mZA$@tlTF$nRgVW@r69FJpij46rpxvmKfxFqR$bNja;f6;EfYca z7NxG$#r~U}%K<@9^W;s01!e4!mj$tA{gLqqq|=G!O*_%_Vhp!9{%}AZAIfc*qHo!w z)jA;U8o_7j5PeSgIksZV#S_LD1@@mZ=Rc)eK~dOr``koubFbZOha6(Y7NNDreuY1dX zE<||dW|LLRbH@-l24A473b*M`WGJJ zqV$5zzxHfj_IXq?b>`XjO)CHI|Jt|*yPvLVIng#gu*zVzZ1Kd38Z4U&kbJj4`wi4D8y9!V>dCFM=AZ0UuHra49!AlXw^i6-$+_UacXZ1UM@UgBRq6+>6SnHW^Dq=qS>%kzOamg8@# z_vbeGS;UuX?ZjGHWFs^kp_mJW0$>7PAD2^;T{It8Tsu$SIQxSeT9bc&IuGZN=qXaA36x*P7gu?Fm+gcnN@`a;@jja+ zJeC+b5&R_I-e+p~r23ZJa;28*EqT+6IHj)~j45Ge^iXHw1>SYd>$=}_bcOw#6GdlC zI_Ny(|LEfq%Oy&#cq=aj>5!8}{0-*!e8xVx)Pf{FVnT#XS{YfML@4{7FClSSm%Sgwk1Qr#9`GX+DI5&=D_{g#4df0Vil$a zW3EBIR<~GwzIUZ;+7oJkW`#E`)u`1}uzZruS~FU)){k=Gbw9Z&b)p44UQ@Q8YA!#a z^Z}l$f>|8qi_b#?E0q}kru@x?;S9tj>KHZ+qWZw1hXq#n%)}R1XY67Otz04*kqTJh zE5nymG35p;)`z--=JgWfz$pTZ{eL}08>)b_N>vz=p0Eff#4Zds1ui=HjnCMWPKi8X zpo4TBn1V_U?x9Kt{>4Ql9|4{C7!RetP*V?+*D~bkxO-mVp^&zQUTpM5ODfaXIdLDFfla@NKd_!D+VIy#=|dyD7?R{j5@ zk9%oce&XFeebh&2&`o5ila1O0`!RtI}vE`m|YH#6#*gFN2+dtCN%%ulCDSYj7A4mK{*W- znzZOGw@}aI7RZui`Pv@PF|_xQ1B{0Cj0l*c%&}t+ncnT@gvp0-Nlkh=EzJ&=+G^>u z2RZQZOjc4;MCaK4qsWXULT7+yVB^)8lMp-QmgiiniD)y!j|~?^!nkwZ}Dk@AM!wIo-73n^x2T@HawUlFW~Ob z!RO}Th*S_;m^e8EhW#p;GxK{M5`%yXCc=f%iOXC;m49=|oo{h{IlS`OsGJNGo7NS) zk}c_=HxPKYF_M9FYFvVDKZk56G4eklpf@jZG_9;rMnd zU$R^zB8JuLBru28r>u&c)m0k*FgF~gy-q>OF?&{78~?en$X(gWa@)O@rJb+93|ma1 zbnzr1zT&c&l5f#DAksy<7#)fX{Af^NaXwV_Dq|9Aaf=r>aKMv3x;?wrKMmw$|2)8} z80ERxmFwtopO2H{OR|Ir8!(=O)n=Q0^NCJ6o`-$D=81VPOUR6b?)Y+F>#0lIKk0ge zP|R1CGP`dE?3v;LlNe3|nwy6jHBe_!vo(n_pE=dDgb zQWZwZU!Mh`Z(GyLprc{f1;7g8SJ3A+!wYC8ds4P-7p&4!t9Jmsfq#196@-|+&f6D> zr{Iws2Ka%K^pPch2X^v={wX!C;c0=}_Ne7CMm418qz@P~j?CkDF_#)9?yk%3TyJ4cH?8SFsEXkzatPIp}(Qa?2$ zHs~o9(5U|TrH^_rfx8*f>2)I!q*{Zg4N=Mw)hyY?doCmvW#(~!=7z3|DZ5#Wz1i9w z6`+D(CH{5`{B<#=avwOuAEKn;YT>LlQ3Lci)15-PrnE&;g#Cw?xL<@|Ob#Yx9*Z`Y z-w$g31NHnB6%N32o7#&3la*;82uSY`bmy@&8~ClSZ^Uq%aVUJCYqz&2WaRLy@ht?M z@JlfSAf(17{fB+2?!g4@JmL1fvG?VTHa2+OXwYeBUQ5%z{<>Ip5fE>Iyx=8n3e1NB zQ5M@LiZ=*>UV9+HqX)OZ1RZ)~)!JH`I=yW?^N)uqncrT+;cqYvi8jXR*|TT8k8X5i zna4{c$8!U2_xgu@e{{)$BEzBAN0}}apjf@S1y$K?9E|pGR5*e@fAaU|?NJ>E)Rknx zA=wDlV!shL{Cl0lDU$BRf82S5^V%2q_qAt1Y4{GVlLkx)Q+Q8t!ebQ4b*WB(0x1@I z_h%a692^k2lflLcS&x2t?L_6UXkG^dRnp4rV4YXw5UXWmB&#CRku30;9H+AY2lhZn zk0dA}x-2h~Ij+`l^PC>I>Hy`r_A1N*BXGsz(9_dy>-*JKO$J52`~Hp7;7-><0J^mu zmIdd*z(b4?)+ey>umpaDI$b{Is8V2Ok$sEwAybB2i4x4#jdP&o*5@mF*&xN?z3tsB z^Oa^?99G7cU-|faG8_#tE*HCxQ4k)Ne+;x!6OW|9q=(Ddz{9efu*PX(_6EOGr%|MGng3+D-8JRDaYGRBSA zL&fSNj?BBKt^Bm-MU%=L02av?l7et5e~@4ZsD#|s3E^{6OUO$aCf%CH@+wx%V-Yn% zSpZwN)P_@C+Ap7S)|A}tu>9y|0g3|?&>n?sYeP0_gv!jhzUgDl6uPQ=ozrt;g#bJF+5Xg&;|nn`Z55Om=_ z&FhQo1SI$Dq`+BK8}TS8Ygb@_h4WSA@%EcOg^K4wV!0R`Ow5edXJOF|KLUR7bwXUCgqFb!ji}` z$Nl2bHiYcY#^u9-ILmhhkEL}aLCr|f*WlZ#zM_!M-kvYE>1<6^=86DW%?~%R2LgG8 zif|||`>b2(BWxEZ6NoG7Z)r+GPj_vGBgN}$_w->3RX*U_(w-RSvOzQ70qy7X+h}p* z=jBN!bUCZI^O;wt#No!4P`vR9encbjA5LJm?}1BzoW4#`UHfdXFnY|lUuhQb>Bwcb zU~&^{l$!HB=H7Fb3tWfIWy&YBKcD`MuNW(t7rU%v-&s9=elNjg`h%G9Q`C`M!j7i& z*`FL_;o9l6Y9@5u6OXdt+Y7@}ihUIFL#g^&-<9dm-ssO^p5cI1ydT*EIHD@!?mHon zPX-J5=I?Tx&aAr;&#oloU2Hqs?aQ2I@GZ3?H1BqJQu(j{MjiTxp!*@fM35@;QG1kl z-6M~tH>cvlwd@YSdA#6Fx;|le2gTpX5Jh;!|9R{&N?P%~l<(X>zC;KrBv*Tn_Rep| zG!kAJfjNcp7pN;fFH>=KBTT+xw;^wFH}pHJkEO+aE$WH~;Os*-{_Y8u*ZsMww&S_` zmejp>t(3{4a0(I53nZ)Hu?;OCiT!)WPd@XfzXxmOendzvEo|LqCwWg8I@>W#9f2{R z-5$P*Z@o%oPHs58FRN@oRKA|O{BqFQGbs!?v{P!Q0OBL5x#3e@*-Fa~mR&_T4D{>2 z^+l;5P*`d!e&F=(d{yDdbn_@mnwOgnpraY6g?ON3@}Q3UICkt3ki{>4S{<3EowP3eNR}u~AJhPYjmtg3`R%^OC15PQkZm*=izYm>X9?~-|MY>IO z(wX>xNLH#z5!!2+E@?s0pB=j>GX)r+UN>J*(}x{svHevV`1k99K*W?xqKixotOmu; z6Oj8z&9IlP?A}2I@W+b4eak49PT|iafAg5by9ziKuOYejurQ$2Fq0+HxAi$M1aEnh zl)5-ObSakjM3d^`etG%gd9e>vv;T@z&NB9pVa%0n+hHMhkycm{c=Xv=cqtk2UDPpgjC4dCFP3NZzvHoK^?9C*s}GhJB^j8x`nbo);U(r|fwp7{W2 zUJ>vy58K_Ca-<7{3-hmFr&9So5q<2S!d3H?R=g%vQa;U&&{7mT-Kdb%Q@MU=Ax~mg z87CiOJ(`s~lWgXqDBxL(@*R0lJmKNh6YeqYLgmXBj}(!6PDJ$)8jI!%X!05Xb9Xg4 zWkGkKoaO+i^2A0M*9UR*p^3cY^0NaV1-9ANdYV=<^1N~>6#f&F?a^%10tQ{g*9GA& zvhN!XtoKI-obNqaz4ba?tG7h%`Ht;g!(KyOLn(o*iju113_$AOzTru0H^QX8zay!t zWBNeRyDxPDN5H&B8rbBMWv46*p05*vayj7+WGn%t6aQPsy8falqR8AnG zv&0i6xmx!5^vj5Q;XpN)31&0!AGNj5-BCM$wMZ z*!{|dk_^whk-byz_K8*T=Nr0$@5xAh12vR!J}#gI#)ASFnxP2HNP&X>7Z_rfk|cuF zC%G!oQrEoHg+iotdfDxzgF@8F19A-xI^5Huk1%na2_?-Qk67Vz$9JLWQ7=DGuSz6( z8L_P=ceE|l6SfCL5*^sX%v9=(t0O9y6#6$6j&#!jom6~P#@G}9+{G4=wtb$ z2UI#5vF?*p1~(!#I$PujI5|8^lr|0Zvxn);3^t_q$%glz-VPdQ+d$G_%8a(Mz_C@a zQdgk)60A5$w8}uZ`%i{kH#W?TiG;frn4uZQjbcg>038>l9aXZ<=|U!&2Ab02eYp2! zHido-tdWDg@53nf)b95rrUwWXvp2x=ri@Pg>~;9|eEX3xMt<3$Jiq=VzzL2yLaDd< z!P#B=B>TZ{JW=ZM>0-c&{+2z1P##Q65nV5_Wu#%PYd}eqS7UIj1Wr#hN+J>8n zqFjPYp$O@8!Nz*>W`gx}2>DBhxXtl#(iF?sZsK-jKs28KA5wd3upQeo>91X^IMp|m zNohCm=)FYf!8Vmc>mIKTE1Qo3<%O?I-xEtN)$!5L?`c4bAkAHvwm)$gi+0n@oq0`q z9SIwx#~Fa+>-5v`yKP!UV5nSdVV1uq0c1l72b+q$AN+0L$WfONj^5pz;#l=N*hGZlk1u8iI=smT7rzT!(48buM zwO!9sbC*+w`J>TkQs>%mpJ0Q*SohW>R(Lt#@PnGJb3jW%-KZYdug|!0&Dwds445|- zeWYYHnT}F>!behwwdS`!A6O`pG9_q1hYcsk zEHLxhfzrH3oTv4`_&Tj_tZbiNQ|VW#rzckjdK9ir#Y@Ke!cZ&kKXO@H>92hbb(;i= zw4MR&vS#=mZpqD}`UkfF&q`hPt4Rth@wsCzOYTil&|fOoLIU602am_w=*gi*IkyzznevGkH}<*E1Vtu@s%Q zpA4jRylhv=Tjqu35dfiW0GX4l>eC+R58v{i#mM_Mb8&ot+IU!2AM5K8sT(GJzT`P; z+Mt@yd{B(*!0=hAJV-V9Q($7)6zpsiFbIv;((pQaZjOraN$zBn4B(O|UI*IUaD?~A zCVp3e4`0d#DQzaH?Fr@ohkqhh+Em6+Xv+2)&d|jlf zV;08Cwr?QylR-34ErMftzV1nnW;aWg8CBT&n3xq_yGCK*dgDuZhnjri=0%mh<6?N9 zmQaB!YK@Di5d036ZoIx>W-4q)4!{jA2GS~ORIrqw!R&1qtVyQ z15(gAdLUVT%+1~nW>cW|eZO1LR%;I@OVWLYS0|4}HI;7{T_eV4xelAXk*q`9 zVgGgje?IcWf31<;NdHoGUACIV8Q%|K{cmPAbgH1hnq*^O=?UTZO+^BW$idOy91p^ z8l5~XKkbq;U&ZZfwG#t*dykeolY+~lkuyVR$?OHZI5|O?XW*I z_19k=2sXHS;x3Y_ugoXjYbBKndDE>G?p!({r?gT?ZqXKSp{DMA=!++SL$#?n2hF*Q z`L?$|f7q931v?+KVk4Ec-B5DS~qCES^iqJYP`9>%97L0=Mvr{4p9f+1j@pNcNa2 z{v0rnAWi-huMC1SldH<6*8th{M&cxznaT)iOlVFr2XKGx=ia^A>PV{X;Ifz#@(>uy5r7&HaPKCAyok66{M!Ra~g;d*hZ{Gsq&rG<8?yH*Wbl zY{HgWxSJ@y)jIODjq3`qQJsSUoug;as0&*K-Q}T6<6*|x-b+$)#aZ#b;NqpIOgAba zYdFi)VyTWL>w{lkR-6Z1uB|%1z|qaa`S=6UXP=>^C@%+8&CPP(_Y(@!dE^Oy`W{jN zqG{_wQ@nRB*_p1i@e=ij_IUWN@OlhW$UVfG7`EDN5BF@kD^RL#WQ?H>WB0@}+M|>@ zKC)!%F$=lf)-MN#YPZed{ezf2KqFd@cUD~Z&_CRbD96W;x|AkX@ZjdIqAtpCr0Gdt zn3$;Vd>qks7(Td4w#{@o9FL3z!)TQ2klteZl?i|M6)|SMk>YJsOCV-V_B^Ef48|1= zgHY-r_x$4+9%EgaEJc0~0(DUMWFld*sp1Bc$BnTC=j#GX%Ot0d$v$6JS4s~v(|rLm zRNiq+S|#^kRSi0>o0aOQxn4KnM*DYkE}5;WU4a+NR9(b}cqvYf85ZH(Pgsd^y@ z3%MlFRx)~Fp@5n4`qWe8VrF$($g>QYN+8S+tMdn>AOSv0At*WgZpyb<7ln z&L9Oo4vttUGlWAbX;nH+LqWr`M}Wz_XTR#O&yHPB+mY{Z&sAV*t>CVSN6Av!E0nOT zqQh|tlk@c_9}con$4nGt;0aEJ-oeE{G~7dn&G6_e{VH$FGDRI5vtDCfzLl(abFjx) zc$FeH={DTdm`jb4(%yqz5|dzjNRi?sK0ds``|IeyWP@^PJO02OQ5q~kWv3ol&zCu{ zZSUAEQ=+@<{LF+yV9Np(Z92Ot$-(a^P+)8D& zq1~O)Y(OjRsGi4qw z`{+8U5d9?H6EGF5Grl1h^H-@?nRS5>wRK&vy%8#}!z8rTtVe9Fk?#(aiU^;#z(m9b zSqs)jfD1k#zkL}y_ABX{n5~HWT7sCs&JgN_AHV&7BRg`^b+sLtq!M}cs`qArW%~C2 z3~fWaXFnb;-n<&ai8>@UKfWQ?n>^pkEcnud(aeY~9+qG?F=i}b>z2yHdX=Qk!Xy$A18zw9N0 z#rz1BPlZsY0yThXy#vi9Wp6duMKDA#b36L#inodCFu zUe-%j9GETD^>ge=S$dt`k)aqJ*txuIi^aSPt-k_k zhJFwJ^E<^~JW1@usSD1dt!lbK>t;Ag&l6kRJ7|D1X^*kG3qWfgL-^e{5--t(q;BC^ zOuE9d6%s%HwFBep6oD9Ku62TVV>OPA}wgxxUCc!_9H>D5X?($&FLX9NZj{Sfcyui4zE`R zqys0T{3oVaewP);w24j(m#A1X$xAGKArB^Xo*1m+^`Xy7Kw&vJ)J|FzsD`o9O=rC8Pn~cRm@-~E3wP&J#xPow;ZP^xxWxiB3ItsmFP*Vu!u)UIoq*; z``|2C2q*hzc0-x{CmtXUI+NXR>(`tOr9lh8U0oM({GJ}nf@tl>#z#vJ4414_@UGNS z|Cbl|z-W(%rppHR((zY;tFSz0;|g>-St?+?%d);k_m$^@xAvDv!--r7?beFrz2II} z1U}CUZ_}Kk#5-FR#5)s4`r0w|@SAZC=ryOsNK*C%f?`4ELXAOXfj(cwYbIL5X3Gn& z@9}e-&FIc}E~`mtI0tL6;LT_IQ!n)AXc>rKXtb6YS-YeJZ8@$z8gZ_k4x(^6?* zvG$I_J&<}4=X6TrZX9g#Q?QX5pa-S zy99-%CR!74AYv0B}WQT$pwME{(hq+121dT$xe>shm#2CMy+=p7AwwZShs$n(4)5qIMijY zlw%g|)Rws%#8vxye&p?!2u6j6>;a^3n{s|nQf|K< zdk0xxKq71SHfGA=6v_>5=j8SYvl7>nWG6oL^!qoadSnL`b5{dAi8~$~A2o_&@$U`~ z=#BL~BQ!;fn_8evuV@7F{Q9e^3^`dRAWO=!N8C-P(8Y!+I#33K;q!w;|*FeTs zV_K8b0Fvn6c#~5J>8c$E{4q`nN;&b7rQJa`r1qohH%Hz}6R5SpY}a+ZQC|J5Fs{ZND?Q-Z-Mc8;bs{ zF}zL?h-H7Yi85XCdQ9$IQ^(Puy&KW%!2$H(KmPuG1906g+aRor*tXH;X3nA`cq*jG zAUK}~T=a{_n!!VL6|x=Fcb|9RHGK^VZSB^h(t zx8Z<&rNo=jgSb7=_vp9Zwh7&Ul4se`(T3{Jk!^}*78tXrw*T-}tyk2H7wKA)rOBX( zwm#JUyTiE&=K@=EUEBitY#)RNc&>bQ@;db4+A|_ z$9COA-*UxhX0Xh{`@ThxeP=qsl$xs+?mfP@Lp=TCkNy-yQ7;8CbcOf==PB4|9Je6m ziSp9dhhCA?>)s%D=3HPffHL4=F@Cy~%y_%)r3T5*izUR|0y;Ykx~O^DcUMWc6%vb- z`g%5$gPLl+TCf8%fVV)-uz;-r#rb;>L6KM4uF8i|>pf~m7j9v ztKZAY@&VsGAy!6q=dbe{k23epm8XLxU@rm&4$rgGPhr%|HeD+SClX~;#Azv(ov$M! z&SO&L*F(FLY$REVyN#$(?(od2CgKekrP!#vmg!Mi*MlUWO5ZG}GV}PU5mUhp0LS5) zdkvJ^Ng#u%^TEndEOcu#`#Ly+aG-7JO-_tQW_ZgmWFja&JA*m*TARyeMZ|#nS@UYX z=kh~3+-ZWM%@>dq*JEX%<&k0mNXU>Es2ylFF|?~hmBFcW)^>0oz-wei;#+-{v?Q?$ zOd^juZu;mrL~_iToJx1Q1}Jx|V*9YJ4Oy%vM28cw)*F>}J`D~QSw7c1@r}ZS0=Ff% zJny-v0;@p*Hbl*n0*b+mKUsHdkCUN#Ieta-`^(tqI-4wM2I?WBMVn zIXH4}J}ce`!W&d?`7U*3dC6-`*oSrIp@)ft$>u;~2wDxD}2%AZbBP!FO98J}_Sf z=HYRF4rQ`RkTw**MGD@t8zu(yu>&fHvW9bV#n(m(S*c_YbItP z&~v7Fjfo^MXB0H6zeIQ4<_T4m_oN}pDsT{I9KhJygbL}Hjmqs_Na>U*3)u0(5Rwok zL4A%cK#{br{v^i4jql@$Wqx%z7CZ}}cWcA>fyLKEC@(fUy$sq4rGFe*=VMVDZS zCq<&;3MSIN`$N3SdX&;21FovH;%VyP2W9Q)s@{dnAY2F8us^lpa$vK?8ARpf6m}8@ zGwfKn8yRNTRY3!C*mCn!cnLHe2|kJw;{>_8-863sf1 zrTCMNcF`hQdy^WNyU9Sas3S~X2@gyLWVrzCa05>T01pVX5!YLjbcleeHP4@b%0S_C zjxKN0;H4d;kvQ)7;9UUnKrh6y7C)`FFlZ^P2P1!D4t@LjN`RmDc} z_+#lTu%BUYXJ?~M%DrZX7g*J-v)8)Xv@Cu24*(Vv)v>%hznRfrQ&@p04#8q{@1XX> z?+SHUJ;Een%~agkzzU9k>?-pvR-DLd?Jfq_e~Pc(Sb?&SNe z2JBaSM-*dvKvz+2s7_!f`mox�m#SK6(x&STkmSj{Ww)hw}=sgN1DZD(psZzS(o3 z7S0^t64#I=&ye3NG_b0t@`walXb0Sj@S*fi2Ai4gpCsT(ypFDzVO?D^>7N^X(&DpR5WXm+F@BoG+E22<8R|{S4ZFBQLT}e$S+k0^xB!jE9njgcp2rc8UZ#+-Hd^Yk;XmoX^UzhyS_xm^0_zWkWFER zpHZw0s?Hp4V?6Fs8N;&i%9xy>1n#zCk7oCLew4G0W{ykDa;n)d&-Thi(nqn?WfU>m zhZ9ZW;A26+-9DtZzHs>zq2AKGPeBRUIFy@M6P-C+lK}3ydCcUhc_PWDlrq>R*CrG; zh9IAC!m~OEU|P>ipAfG*0G3H zzO9?|a4R1Rwz3dms9m{pStX%^E6CB);&r*H^5?m*q~XBF3{wbxe3HP8=tPpq3>HCZ zX*z(pY$o@@jj4-;QJ>i1jBjMTl;5k86&4z22vJ~GbP}~b8m1dDn(cYGMea00)_E@n zqBX+yR!M%D%WC$>O5L%P##Q&UJhpPa5l?*5xo6l+r**K7=0w59skO5zPWiQ|fA>Y8 zVV!#AXe6L@s=TgN*C1XfLJ8L!ke|8(7seOW6F(GqS)HBT1jo@EwXE_K>ijNo(wg#F zeAhXO^od<9E7_7$jEwXMEQ=r!sR5tn$uuOj%c)^dDhpq&BhuSN>bL7V;|(c!!?LFM zyy4Ie*yxc1#0=PMq4|-njd;0 zzuW5=L*LaoT)a8g^mIdg9AnrTR)d@#S86<(%s*V(kNJi_Q_CdK*<5D75C=q1>m_*f zi%Co(KN;9<+nHFJ-MafKTzhK0kk}7R2j}mF?Uv+nm~!{LSJ1MnwgWL>p%v3pV%C+o zgy@{^#Z}zwiHv&VESVcA7g-)Dn66zY^@MTP7!y=DKs?R-87b6yr+Q6}cwmMBmsl6Z zjG&_%TPJ$+WVJo7b;SEZH-Wt8&}8xCGmqUb4zcj0ZU7F{Gp8LdSu}5ByB3enXc1YRu~-y!lp=&{blW`rB2?IehaCWMl72kZDS^=#Sx;z$_FV6w!>? znG<7WLXF25)Jz*;M=o$hIpp`!UwKY16q{(MFFaR*n;-A7UC3L7rU|6k^Qpfd+UYOv zm1$S(qqA3%z+z>&@X1ppeJ@4=?Kzhlg2=Tq-%gj@<=z6e)7H4^1@gRE4~5yoLS*@+ zf6Hp8!ll`qdx;9c>_^j4BRIRgVo%~n7Mio&Sg!HPdFy1&SrD)@x;1L~Ug=r2FR)fP zh4({y3t~syns3gRL^wQC{&L~`I^;&pHN2L`6Ze(%<6Jq`8g#h=T*ie;Jx5@$_qNX2 zp3XM&)!bz>xETBk#_M`CHYpX*avjlVkZMhYfc_5*5gK_vy;jtsf0ogm!7P%r(CtiCw|Cu|F;utlbx>QpXET_MD9f zyKxXYC7?%9vh!|br`hh^2`{~K;s|E+1Z@9QmeD*mQ^nb@y0`H5yoN$8Z&>N|$DKB< z--A2wuh!AxAL6QUHQWt(_|TMCyIZ^4tuGFwv02twFNBI(D?*pvUDl;fQ&~vov{`-^ zt;|V09)u`x+@E^NfNZ-kw|wH-6-laTCL}H!*+@IF;1icS=eM`RYumi{T@zDx6Hd#W zF;}J=>p#LfeCufmq|nBewskc93c2^up7U@u zM=~}oQGTbF)s8+_b?0kEw+P`H?^h31gRSxJt=Fe7-PwuUj>sMTIqo9l=Fw$yyGPF@ zptwoBhEJjQq;?*via5XUqR3ERgzd5jF87Y1h2@7yD1A>>mv?4)iNK#vm|DFnF@&u0 zdT;c6>)2lYsH5bkTy4RjV^)MFUiV5nygETDEgmMIe;AGRXkHCJPvFxpNJMnav^o53 z`+UG+dp=W)lCZF(iLWmCi2s;uMx!P1K3;2f(f5KVzOqb`78&?h$+FiRLJ-b()SdUt zYYdd17(0M)cJX{~OK9>s)*9H+5pP%_|5fgDDVUIPd_70e+bJaR;B?VNdoduNxh8*v zmYuA4eQ{?UdM776MU9^Wm`-7>qbALiTRkL2fSAtWLQx0bR@3nxnySQL|1XDy1e zU%avFQLm{SS?rqacSx|h+GMXduP~NeZu;1Tg6WZl7*Z(8+XvenjACD(Q*5!~yXoso z@%}`35dCeD@;xs&dcFK$ zOZ6K0?%|^qI`Uax`Ly@CU&z02?mY2wA~|$W{3SojOhN2|$u1;cz7yT*GW2qJxmmj@ z(FA&Fe4zx%l%5MbEN(fh_QlQHCbY(o;{JJuwjox0Z%NpyWxAzvL{Z2Hy7%pEWN+^) z?|F?Bw?IdqwZs?YNu4oPy}UPCXL^C)Y#*pp`{{8a+aL1qSPpin0rOA~MZ6BFaBMf6 zuxq2%13BzwgLKUdrLMk;;@xwV@(t-^19+6r7@A}wkx1^yW@h**10&U?`y=E_=;eU{ z?AbnIlKf<$AlYjq(d`~`C;9HHu_p!Q3e2kl^fK{1QSjKX$<~SExEzy6K0~|!>Y&WH zQA!+x8D-g_Z(=dxJfU4K-`h7n-wDQxnY5^B>(aY*GXFUr3zV5jk>9^7NVkVlH0lBV z5TI3CZBg28Ihfb+UG%Vm!C9&wD7)TuFCu+xH)cyZJoLwvfgdg{Jv$0}D|tEE##wST zu(tR3Ty>&n{{7N>Bgxv%r{zq!_&L0YdF7CUvO7TJiw?J`gJt*kSt&+ zp1o}$kaiZ0+VzqZPU0VoJOFehxziF-&D-u=r*Tp}PK{$z8U!)IA25uCfV)k}KhJd& zI=@zA?W>!YZ7i6#`o)GAG#8~oCcJ#oV)fE`Wtjac!4pbFi6H7!F9ZO7k&6$!Kjnl^ zmc_nYt2-fdupM)h$|nV}qP$)}1CX0FLYS`X`TlwHth}V}ZVWsiRpHjx#~D5}tmvK0 z>u!Tu9j}W|p&3y?Z_ouG;tQ&@kW63Y6Apww+ot#+kg9h8`d$8Vy8P7z8s>AS%2gIx zC3o%o@@!2aFa<@x8G{IcYrYTOqwoOX)b?IQFcQPxL9|-^L2M8v0H?79Q!!2@$&qI@ z!B}hK5Yr*XQOFB%Ag=s#-T|l>xHpelO2t-9P<@Wtfsvrp@-tt8NtXH(0NDmClwY5p zW&+wNa)11h^b#eA(S3^YUg@S&%)xAjj8HGB`sL9fDy7!4E8E7f^Q?H`s*bWfSGS$= z0JmBGi8en7W*xlsqK81PyTH`Nmye$F8((%iRMnw#fFYYi&o*(hH%fUcqzm*Se|-bX ziy<)WPNbVi73K(_(20qV+MI%s}C<`3_R?s~q;_BnOfoB*SP$beBtzdrebpI_C( zCkWT|O?|~`Db?%?0WctyF$HM`H7xhpaV)s9_sI0d**+q|Go~UBX6=6ztWx@`!jX?F zyh-aR6Qn^sB>b;mcb;d@J1NAA|5e?a$3wZkf8g5pB#IJ3k*r1brL2|gvSiChQkLv7 zhU$c|L?u~gq=anKSVqRyGEAk6Ok>7gmY4-G_GSF;8P(~W^ZEYq`|tPj>eV@!XP)Q2 zulw4s_jNs>W$nJnJuS66lt%EjS8(kW;s4T@+Ily`rSr{guP~gcVP@xtgWyfqPlEHm z83bl^PU1zmM&f>J;6M1}syYbM+a#22*zST~Wl0I&J{6quf-gXhfbzy&K%@O)oC@$d zNP{70XT0@?0rPQF@LVI-f7Q+5z10bv^49X{O`vO6={3j}Z3@jdS)vl-x> z#-oWs8to2iucZF(MS%Kq$?M$P97fgB-R|uzonr^s>LzHg9=)IAbFUCgo*&*waSg?5 z^nT;yK`c)~IgS!rvi~G6TXlNxl-RQ$$w3rZlfGm6ihpPV?>zY%m(KO8a&D&Q z1=JS)p-$Ps4d9)>7T3L*jf@i}@VlNIT;~7&em(~{-2>B@*DX7WZMDfQ-Q@sE%WvaH zD3dXJ&sl-?Q2_5z*YTY*ND3>?ImKtV_%^9vQ&se#EyK3Ee3*k^@_4@Mxr&5(ueR@> z#|y1KBES8Fldv6`|8U3#b_f3`ozs-1P*@6Zl3>*{&lNIP_P?q~*bSk_3wihcFcx0^ zs*XDHk&Qh7Z{}fM?ONX(pDrIdpDBK8txs1c)SycndI@F7)j#=q~yh1iy7E7!)?4 z=YMe(LJr;-y!vuwPK~q8V+}x38HNJj1$Zm@oQKA3L@=-f^ntH zptY;30CR&@UpNey5DWy+1I_&(qPl*p(%^!dGEFYwm66N}+9d61{V!|Fo+r zk2MEA{(GaKGMiFr1veqIe*r+!3lGfjP3t&Y`hdKIWD5=8L8ocDqhTtIxy-@e$ zt%CiU3Z(SbCnSv;kZ@wX;Bq`n0P1F=HurW8DC_sSRu3S?;$F$Yd%IrP*>;{K0-41W zDHpHEdKy-Z2zuf*7hCob%z16fmWK&3Z9B|kPPu&y6)wK!Qk zQOXQ+iQzN6<{Z_7sSR_b#|w~(I)#TnGb56`y;Zh<+yl^wl@V3Qj;$5{*#SFv9|09g zwq5B#Nqaw&1=CW_AaaDq${TL1TfF5?JU1v6~BrI8nFBt!ij`> z0LHEjc+9|prt0jzyzW&N+hBlV9@pd7bDGFipo0B|Q!`nBf#p`+8?Q=V(8_u;^?$Kc zA>X9b$FVZ@#Xtb{hC!-PQ1au(Rs*od&$?b)qjYo3kMM1cI$n31%H%*)&Qk%9eoB}8 z#)M6J{#DX5LHqIM@-=~HIWqa{OKrDrQ_BG+?gRQ@O_AH?kY^=WQe zz&8GI<4p`3C<%TlKClrADm5H` zf(p7IeJr82X+1+Lx?Jqnkg+eh*$xaN(42GF+q-JIzO+wg3j$xG6G#>N)7G`14^eQ}<@xug727Io9t87)B zR+3|QV|>lMpNlx1;PYka_WM@zt?Km)9UD1dy5xM|V4NAi=L=t6afw{f+xl!`!`t6{ zbaFk`g1Jq?NDEC8ui0^mgH;QL@j;55o-Mf-gx)$B)dspQf9Y7RgKOEKp0Zz}5}eGz zN0N=T(4bD*X&X22j(6>o_g5N*{&)aexCTAv?pU?-v_rp~<1C7pvtnbOR>C~=40zwW zObi!g<=HM6=XAwZW^ib0CI~{j!UOC?B8~RIvxpv*+%qlt8 z2>MyPz3%m}uSRU#Kmi@8_2-zNV6x`(rHa1EKlZ?Z0;TVc@~5TrC~?-~`Pp0(T;Fm| z{G-Hr{p8OP%^b&s&8{~$uObJ}f&<)t^wc-UWDX=V|IBcF=U2czP6B8usJ648F^Kf47r$gQB_dj=FCKlcE%qVL&G4jPM?A7J!0zQDwEf&0{d zw+u|Bf)<<4>Nax3=!`9AFi*h9l0}-<`<1H)|Fa7=u#{@ak*YyU4$QYlQ$1t~V8%fr z_x~V~`nEFq(i^M==af}a*Mf;20Bp5y)KTm|w_ha^F9%rub?RA?6pb^mL0cnL>C0)- z|9Q$Lt^gMvMc>@2v*&iSJA2fd+E)iq zX|%-0@2b)GgI~aD9yHl+b14h?G`Wq>~-;NDH;wg2_cJFSAy^g%pdcFIABbIvuV*rA#qMNQdfbHTyj{W;eV5e~XdV@eS9)5UV3N zggCO%lY7vNjlr6D%kTp*2@|8yDDPX(Q(lnK?fKLUvo+N^zP%Vj`)rbZqn)q6bOwHo zSaOG6_078YipJY3^-sX78R_J=dGn2HJr><`?Usg?mu0%6y$tO0V3W1 zi>tiM!x=rZZHjkAZZ3TDP|dcs&%V=qA&tJNFyfV9Tc9`L3iA5A<~M)Ql~8XT%@#~j z#4E3F0jHZ6USmn0b@pPCjz;vn9ewybUTFNf7Hfj2zBEla9_kvhFLYF8I|=}>+1Lx< zHe0?Cv{iar@z*NC60Yl2Ip45^KOr7Naor`gH+P|N?U&l?R&S^VxALM;1EuoC*LXg8 ztSPg5B^XUH$npCen2nsR;@L{ywKXZ~VMpm_?DBx?qJXe*m#JzGe|w{F48Hk_Q*;O`%(6>t6;$*$TO>`EDrG>6b1BU7s~WPX(ka*bun4K9AAz#lPvx2hi!rURS*T z7wm}N=Y@*W+F-?koo|o4iWr8<2a2c$5Vw$7XHpv$Y3n-p^Oc_!w4m9YB7h3(zulF{ zFj!OM^OC;WE|A@qTq(27B>v5XZ7OeDs|&ywQ|~a+bozC*lrquamsu`g4opeCO{7#O z8T{MA$>g*4S%LP{=kZ{8^&(_Vm<0&PZ9Yf-2p@gmBZqR|8D%%$*bD~Fgq%3H{zK#*7NH0pB=8P+L#@Esvz5zV0|*3OsBjt*`^u) zX3!iwjz-Fm?NCzpA3Nzg@cs##%ga^Jz{kF+NR* zId#K1bDyon;-_uwf*QaJgNFg5lWDU@DOJ}Cw#I2yPkaM!p4hwL!BGQIl*r@GitElB zo+^XaH_Ikp$QJqX{gWi7S0SODwRgi8312mb>^K4qgk8$nE|SZoo-Fi>psPYn->r`A zg%r)vzxe$ambT*mG=O@WnBBK?N>zS4cYex=;^hT)*-~@W>-cF^y`*8UpWeO==K9U# zoipVi*~7ua?g>5fhB?>#2|a7+(APyGcg|X*X^t%%Dy~{7z?uvt45P2B z%0#r%iR#Pqafwkn*;*dV3!gPHI!%dxC8oGk)tXnIb9%G9jV|>~Gqmeyk=Nq+ky<|j zv(5;NU1#$e*HQL_$%U;MCZ}dV{kWqCO{Mle1XDN+`Ooh_-}20`SvjwHouJ5<8kFJnnQaouh`-GZD$< z4+m!E6k~(hmg|S1^}|<-ccMR0O!w8h)m5-$LZ@1)w2ZN4`*Je}2|CDYrnu+`>_qGH zYa0i4iE7mMNruo@2#@Xcy_!zrF2B=f_{@FU#5IC=sef9%OHJ2DILnx7DSig4c{(9f zp1bTF49UzIKGz<H}r$yDufv4A)_PdWdw@tI*!h@Q^S8mNrx11+8x0|^ZH z_V``sed0WsqP*yuZz>{Ok3%evI8S*E-!ozu$j$PIJW-_|V;aYPggy#+FjjRMXF4lI z(9f2H;MFIx+76$A;D#(GxhrKF_x(UeQYVixyEjq9A?4@Z?frdMQ6QRi53={vjdZk# zHbk!P4%G{0x!yBLl|PfZJAJsb<5|V1yIAo2fy)MritJ-zAMisq9~6XMV;`b;XU~ui zBpn-%aek8)OSv<555KM|E8S5VDlDe#b_k+)Ni0}J-;3+9?c~Xtk!Si3G*9E<0vgvG zc!G!vCKH+nQti1`lP>2FT;g!LkMykK%8PfCYI$TC9|GZc5_u>u)91pK2G?SJuLl}q zq1VS+4?+|TS1G9n)I``}?h5x>Cw*M^lI8wm{l$ZrG$FKdiS37hA5T(uZ=u$EKh<2P zDeH0wg0II<=8a_GX^zDr%}nn1>-UO7k~L}rO4V;%3RyU>$dh?&H+tW3o*F?hWv*7~ zqBx3Zi&$d$eJhHIcLtB4 z>$LC_;)xQv;f4HepHLG9#o39mi55%w5(|(;{GMXqMnR`q6{3}uO~8gn?rXM|E~tOx zxx_Sg2*LO-nB$iG1*zLd?J!Zw;0U=b#|iLZOXR!|K^AlWHtd2gsSk`?5mOH8 zUneZCj@zW&&Vyc)76Xi6tD@8s!|TqK7~|+WOAiiE7dohxVnZDr@u#~SJwW9>|BI}P zVOA6(yRt5Oc&D2vgm_4I=9WXtmuN2@!JDCQ_Rf-@_$6RlYeho2d^&@%jMH1Iqzdy3 z>Jp~X=n0hh$w?Wy`;cpRI(NmLV?1cjfQiYcq`NVu=RF86>2jf2@Exx-0ejp;#@c1P z@yxp06TBs9b2ATOc#p_Ofv&p>JrzBCK5mFW1a)pPB6qmF1ukTH-DPIo5o7x1ffptE zUYBFJc<_cx=?O!2U{^CnY#Qaj>!gr*X<6A@4os*!jfo{u&^}qGoJvL3C~sg0cpp1_g z3lN(k^7p;eZ7knu2QRb@(!GIfE%NIu;iHeup*{cp`jTDjJ=j2w73qDC5x98_+@w@) z^ZusRCXSG-KKg^(VKD<44JhkF;QQcR==VW;*0}BgdYH2~>3f?P$Is~|W8Ds~1t%f& z8sY$_4C;GDpTmtsv%R_(YsHkCuc+H#WG}`4j}J6#09{_HUvEx-Us)Doij$E1t)aMX z?%9R5Zz^^hN`wk`$6XPHB=i1O2wbnW!YMLtNVlOME!DKI_j{F_IIX#eM?eQ+T*HD_J* z{y|5sk#|SMf>nR3)|LM}@;q)Q(2^&8*>v*R!}B9r(5IlZW(?cu_w7v-^}^dAdP!Bg zb`?PNL|~gLGurz)I?_u&BmA>J4Daeg`6GBGP0#rl6Qp5I!@xdd6qi3AulakgAK*e_ z5WIZ{3^1XC!TN+xTM4j*V1ANx*gH(T@4F~myjF0%fcG>rWq`?o9=&;{6(oguf>7$zv{_NHc&Jk0QY!>Nt!R_>O zh?wysE}%{Md7wyDp*DBd&RoS0^cmlFdd1FF{v56`1sUjslnt_Gt)r;=}&r|`g zA`?!bZtsC-RUgl2QWkrVrx-&#GS1(o%={eqJb~iurNKf9mmlz6)RAs^M0o1Cd?UfG z>P%;9_`}5%q!Dp62vUc^n^-r~K5msr65 z2>jXgNfcHG(>Bi-%cgE4Gz`~lf9yn5PvA!1tsf^m9$QBaV{ZC{GdHeWQ9|%gyA_9&AQ(9MC{kVwhuh z*1%FWF@mDcV4AT>DVr&NhQYWbxme1e%>)t|LkNH9VTdoYQ(1=f9&|7y&Ox0Xn&hZ9 z4)EQfw>!DxGsJEw-?j95I_A$8s&tnp5~VRvRa+u!UDacgu?OAUmDz4~zg~7qdDND8jknV$ z9v?T_s4aW6ZfuD4#k<^Fr2To3+H;_?6b?g(9!|?|xR|?v`pHX7d5RY)-P!GbdH0^0 zgAiX-p1IJ<_1)qu;pTpfon$+#&C0iH78o&iA**w`NC@b3l zOQ8QQp2g)6unSRZz8?k_OfE46PRZQaAr`FjFh`wb@l?(lZ@=ibC1d#xO&RPq32wiU zYPrvq{^n{NrM%tvzN(Kgt=+hpraP@Uq2d|WMpYYH z+1lb!zqk;#5XDaecJ67j+u?q&mMouC) zNUXMvoO49rZhZo>;kZ+ouvl=N_fC@c!W2>tQeIG+=<@3f7N)kzf8ha6he%?|W^uI0 z#4t8N4U%-ix{6AKV&R{jVAUf4n_QHJFNLV7JK|fEdg!Y$y|haL3;xBpbPA6(c~4oD7GxVKegfHYZ*{G&Y~tVu3A^ae zRicpcyFj`>=L6rtYdtv#NAiYKLc#02gieLo6eKoR{?P9w?kiheFy*WiWaW!*9eRN_ z)S!~!oIq|^u7B?*_46K8ZioBn>SFKB#W3b|`~LYgoq?)8C8xDLP`XREj+&f-7v?^o z(!z~m+%tup!X1c+%Kfl7if+(sZNB0qC!q%59=%A>_gVn)W+srrrzrec{qFP83=<=- z9BkkJaS;Jr#88!n?g73${|?f`w-ntVof~Ez?|#uRmNEq%tIYQCvXfHaIG%H2T;t?2 z9*2Tn(?8cMrVKj-DgVSK%q&~&x#i27q{`&W0xAv+Xdy)Dv^k(BZ*tT{6RmfjIA7Hkbw8=+}xW7>RdO7TWui5Pg{wyw;LWVb+WV93{ znlG!HG#+33Jx{XkaEaCk0uwjL!LZWxpmTSwy#zVz~c zKjvu?{%qGilFl3>$$DkpUZgOBet1?s&~Um;gz+wT@;76g9PgQE;+EG$LKo5R2Wg9u z-mcDSVsboE7eg;ij9(H)n8FF8W9d%leXoMa5rLWquE?x)-N-fzAMe3~{W)^&TR zR|b%tDd(Qt_X-P2`d+|=Y*9~20m{UF=XjRGk-UFjm~n)JSaVIlDN#~uXu{137kzd2 zTIL!i#TV!7QGh(G8?4z50-~GCAegz?%R4?&G#*CVCW+4jet1@>Sa51i*dt2P4F*V1 z{C$lykKn~fOPtR((lP9IQaP@^F{1KUFcfB1`xFH(o+m{C(bn5c@`kKH`jQa!N=}pd zKb`)Q@=aKW~Yf30Dvr`TNRX*0J~cN1Kwzmqc2nMbzx8E1@WO(fRuM&HsN zffo3bm+)xlSD3ywz)7U`5_h=0b0cz=fXz7aT1HIyg_IspLKrnj%v+6Ni9Si5Ovf-Y zl?2fw6J9oD=~thuFNafJNE)c4eL}nT7j}6;aXTlp;>Qsya;N|1tX8PR0-H2YF~jeF zg)#5Y=E5>{gEG+vq$gmo@A2BlmgCUOKX@vAgb2vQ03Ds1Nld|J^yFknc>TitOf$3k zzOR3aQ?KIZd~hlhMGRcl8r5Vc7VLQTkZ$k+evWhKUi?26fH?*+x?X={{&S}}JA~4m z-kKl4T$^}nPUhPh=W@^MKm${M(>2=z~Fxuki3ae zA9W@N+prK^Tx=|i);r+l$Jo;Gzb+*P;r15Bcoy?$1g?1$r0*$LB=avLEHFPW{{n(!ZT@vtw z53L;4m3Pdy^=?qiezet{M4ePoNId1mX|VP)`V4#{S{Sc6@aIW%4eCp+4M=d`t_HzJ z;92s|AKZ7Z2~6JL z{;dT^>P$=@W{3sHRm{J<{_V|FJHD|DP8q^Z+={Kvg9|k?7fBnwg(I-b#a2El4K6** zI159Xd6jdgjWC+Y4NtJhcg**-hy-DM*QJJ3))8@KkZXu|GBniw*5+&E-8zGeqP~H;2yVHEKU(cFrMkx(RvX_C2%J)I;f*E}~oM!1Tyf)1&N@ zt9l=6so!yYCw>r>m5`^9Wz742iRF14VRmp}#vh6{t(P(QhFNU%E|hAKbG~Uasy`x zPMPj+sJr3a-(ZU&93Q7LTS(DIzb6F+e4MInHg~9s$jDbV=re)i3B$dfiCN=TTR%Rt zYsYA2YoxkrHpu37c`TQ{NGScD3v6sF6r92*K`T1MC)_Ed&p&fwHrzk+iO+M#`VsvK z&zhj*&hrKg|CJBZ#4xlbxuSL)*yJmS9IT1(3;b@0js_s}@rI0DD?<3l@`=79UG9K> zqJ|8E?;$}J>Ss7kX(W>DiD0%+#x$8rmfiWIA@}@iJhihiB9Y(q8Ka8DD+_Bb<|?aM z9Q`XGIc=&5r;xqWZgNmB!!b|s&AazRJdH%y3Vhu4Q9^u5}jC*@%80xw6O z(b4bm3V4oz3wxC#nl($9?dU-X+P-%J-7OlcC)8GEot9F=8p_t^(^J@G7jjZ z#N^F;Co37r45yu$*UV@)OX|6VTs}(n>~fZBCp2vG)XDrlC|Z(?bU^r2B9^`HDQ`@rBg#M_FDJS{WGjm9O-4OjtMXz}*<)a%gMuHqc zVaBg8#UdgU!kcUJ^Q$kYO+G#V@eyby_BB^SBA}&N+uFS~a&Kgro<1E=hYjLSpCuVk z9mBE$p%)r_KDJf3m;_83+`eASk8+pt*0{SA+M>uUKbw<4q0*-)@eJmZ)u`g+xVQfk zYn2Xp$w!`+0^-?AdG7Pe#Pu33@;(H~s-axPSTGuSzAyQuS&#hoGZ~M`J-+P$UJo$# zrtr*&eQ;Fs5Eb1YI!t>sjewgRfAo`!XCVE<@OxV9rOT_^8b8f)NMW`f`eZ-AGGSuP zdmnudL)U)6AS_vPK_A$0HOh(@tV@hIQKy_UigEO+@~*4so7c{R`6SP%jfu34bI*^j zoxk?L$Bd4$T#W%a>J)PO!p7cR%@DCP!=6DE6F%m9&kHJKr7bPvyiXnTHUDx$#sZ$@d+Yf#crA|-TCPAr#Z4&9{NdP8|I20+L5>Ri@?w!1e zqE1zNHV^4qK-Z3`Ntl4d2<`j(9BPpCr!dAnVI3`-`EFV+S#31H3AYn1Gjkr-s}0oH z_M111Kr*JwsK6Ns1g;50J}b|8$d%5GH$G=al!kp+S-LWvDZgwzI%>FrpIz?$9Mwk@ zPcVF#b$CNt;9A3dS2H1Aac_8ZnlENZue*MsN=`zhv0oho@zs6abUgN021uI7T-(}e zf^vB7EeQB`YCopV)P2M!jzSH3zv5W=OPz9DIqqchI$_`@UoV!CjF1p|IrMSRgYRwm zN06W(z#o+3)TI&)Z^({YRmtFBmUG@)b8`}&vr|@>a1HRZNzA=&zaocHCqveDvI3=%<^oid0pu0L&y7vj3jjk{W8AM zY<&zo5}o(b)k!#NXkHY@;$AlRWb@0bSmX>dMabY-ppO z-}u9>oi8nb%9_7s6Cp%niHi1Ag=bZuOq%J=T~k`I7WFh;$S!xhClxWa=9t zpc3Q}$fGYeJ~yue_7;$WVYcKLPgY=EQhgL^X6A?S(XTkiQ<3n<{mWf}{r8nivVEUE z#J4K71wW`Tt=4>B^?C1Yx^U5`wh0}dX4Dli)D>sJ9~a=ak{4v<)ne3T-#?FOgTrJ$ zEo{17A;bfPf~2wnmy^lEi+g#XAkz5uZXHJ9eeD71MSc$mo}ecRRmFyzCB5v}YvKB6 zHJlx(lapL%HN-jZ$O+Q`s_iYhZ2tsPF~WJFLv_1TeSSQJ@iP%H<($e3yCM!Dm=*L! zfUw6|@gi_)XgEU4+zTTejYU*5I}xxHbf+y@4CEh4ku)K7$mOUBlvez5*W4 zkM2PI`RqJjo<$1PI9avURQJS-v*4CnI+j%kQ1z+vf4HrrRJhQ6)h7nH$D7|R9=2YW zDF#6q=`+sPio6i^9;dd3tj5b6ul&4-*bGQTN{~<9-Nh#^#?+hyZ}nEcJymQD14Skx zbX{>YyiRyRQ9B|LPq@C2Pt_8Neq1zQ3({U;zP!B8Ko;4W>=e>-V&F~GHlhP+51B`X z4E#=q{Hn3oMZC8P@Jj>VSGKt+_n58(?L&*3>t~&wz_MM#lYOxida`b?D8$F@oc-6MQ2Axs4hJ5)d7+4WMhl4&qF}b(~d$?JzP@t3N}WIMO;Q}PcXH6xAluC zQj?azqVj$%s)zTPYB_d$Ymk_#3M>Qa^a8mDP0xKHzz=<}VXBvU#`r%NC=o zAW7?Wdb@PW?NFO_Ce-mdH`}=B$gVf)t67he<0a51d~2XKI8%>nMwfhcqt)Ai`#V}i zg)jH$_~Qq?Xlbv8KVuJ|cfQ(%BgnMNuMJ*WcSZjowrZ?ew%F?Dk@R9E&q`^Noyh7^ z>w*w3Ba4%DXN%zoAG0JuQLTD8qf$pB#+Xei8J8FvZq*twjgHB?wq`05UZBd>q0(>aYov>f=}NCtj?HK8fos zzJY=htl`|ST#bL6dS=EEgM*1jvJ8dGhhr)3H=W&aKI**TNJX4|cD+8s@!XGr49W{n zzegV0Y_9#@=pmh;wto6`Enpp^-%CLrd8TkcJc?0Dz$M~K7tP`m13h75|KOuh>U7lFOmjz3$)uEA}cmx=nvw?OdoP}e^+I!HzubqgVP%rct6hiraV zdk*J=HM`)f9n45ptf&!(ycGuif~pOcUv%-6tj8V3jZ_jyy8NqkcE< z$AJ$)Zn>|7#FN_Q)#u?spoaOb>U{K6h31YmH4dBz*FM_qnFz@IRj}a`G{(F%@o=%# zzhdl)0={R&i;J<8pTuFoPxAF8&GA0=<;3dId&eCc!a%-*lDx^w^+Bkb&BEapT%uxG zl-JKII0=QHw3;G-vY~{iMrq29R(_60&oMziH?%+l^(aJZa!U7X>t&hhgQe!tu=I217Xb2Pl?S%t8=I4CRD{*fBf4Ri zuy@>_%?7>|n4~Cy#OX*~kl8~y$CnCQnt}#!vAo1eWn-N1#$P)-F2i%b9~#WA`t5%7 zC(k*|>PzVctselh=7X?(grkFu7hyqhJ{z96eoSVC`&;8yEC>>AFCI=rdgHlp!l$5pL5JF3{0S9gz#wskSR)`7VyI@uc2}pst~tAb|ro$34yRU7~Tq z3)MfvYM^brL3ZKsfm9*;JMg;YM|UYqcAhMX6rwX4MQT|3+$Ay4#~Qp(ee@XQn;w0$ z+gJLlS~8iFBqLErc)RNl1*jwq8D}ug`6THi2WE%ozC+0AStc&Ac&eCP9~A3=BYsS? z#5Tk;83Q}h7I0d;FZEDlR$kD{_A;JD4`e{dbT2oeNPB9cp-`Lk>MhAbXN5$|k&mpy zPQB~1v1N^YrinDnmsD46fq~TWcKnAIpuDa^E2t z(P8LMhcDm+EV3+^P`2dXDDHe>Ch4@+W z!-nrtJnJ;oW9(E6E&22H)amL7A+7QH!M1?2RVo_-F7y80<1pK?6kX(~wTJCmRZ&5| zTpl1=&!r&w0*;3LbLvU;R0d5TR8@|=Ehs5P%-;!@cwaZT$G)4%F!oYO`sThF)#U?U zOl^J%^v=(Pn(}1!Lj@xz_5V%1hcSKrxvdUy3Rx&yWKY&Z`W-$z5q?qVX#!;;sM;4@ zt8~qUhIA3GO!gOA162k}VDP8Rj_v_mwXZ{WhPUKTCh>S;24V$v2G_TW?XCikMLJXK zJLVs$!W6L?ez}OcPOT8M`a~+X&G^FCb)?Kh*psj!hZgIq29_S_TaC84*2++%h1PiE zco8yUWbFL{$lDG8k0NAh?(Nf^WR*OBBaI;HoC^qVeB;!zOa) zxwc#U;qif|&#t^dkj$2v1PfgjdaA4&rf-LwZ&-YwgJR8{kSt7Xn14#5_eQt`&DQ8x z2*JiBi>i8{k<+ET+3DN4^clyh+1i`&e7VKDOPk={rA<5pJ2+oUKs#0~)n>F-n0kS- z>;Wp8J|k_&+Na{(SsxRW?L?GxTK17(=d#Eo{VkX6r!pv9jzF`f!YO_>GnCN~pG<9> zhAvInSj5>mqBZOS65q=g)%*(47l{n=pHMZiP}laV8;kJlyA1QqsE?6KRMGMg37oD; z=ad6%c@L)XTWXDcSOLVxa?{fA1V<~} zPAUeYSlCq`L&Z>9o3$amyMIpLHpX7*P{>t{wXA?C5BhI&$hu*UX73lUwCJgE`07y3530OlKjDnkx{R z>tpz|h?9YRnl_T|N+$PT`t-akk=iY-@E+P zRt(DuS}Y#_rr9@8u`*weXUXkG4?C%lN#mfP1@fS)k)z-YZeQg*R~q^A0Jklu-6>{7 za&?V&2j7PyAifDNT}ovk!>_AlwNc^_JhQN?uUiv!Ds0R<2jh*PknIUIQkM9c{uzn# znFcxYeDbpcOnt_Z>N}&ZYsB25K2T2t)u5lH7*GwlwG8k;K1#Q)f+G%H>$Cg*@i&)? zT{d=L;0QdJK3D^aP6Vd$DV26_-XsyVN8F4f7-*uJ)rb*3_wus1)`!u)g1;{kZYPjg>cvp#Y5CLDv-?x09 zwgJVuI1QBt`lGw6&q|BV-Dkf%DLZRTxG|Plm@k5@S)h6}pci8MZs<+B5yD{8UtFNx z({CFlGm6+XI8axL*gY<=y*AY<|s|+2PBH5b~Qu@Q9O1IsG6^X%@OZeNusAVs6fO_f`mmhofp9Et7zsGj)%?~UkvHzTm54?-cKSSM(4Kcop+{jUh<0fa z58;2Tku^W#mUNywg6cngOOe0OwqaVns4sLP+e~aaa;ZAiNz1geX?E$IH!1Q)ld+_S z#Y#g=uk|u*yrBd;Z`SLu{JAL6HiQxWl4EUr!^s`Al1RTuj_+lr$jW8)YQ1IBCnhQVHMD2SCh4yK`s&y_XeH32UppWFPuU z#we~d=$K-Ud{i@^rMOStkxWBG#U~}&THj(KUxZ%wqp@rwlEjc35T4ngu%N|bK%sQE z2SOQo)g=PdO2o5Ks9p5Lp~z9lU|)k{wds*rmHI>&A|x{4A2jfRQKcgl)r!>RCMNo_ zSK4VY$oWE!3EclBXaE|?n4x(#u&}hR->PgIR^p&V8cE2~Ue+x$+kEZ$DB5dz=Tg>~ z2+I%aeo+XV-+8vluo2RLd15csQ>~|^ zR~Ac1$&r}(kF*tkq7zAedCZ~EVZ1iPzkSN6McW!SUlgg)v%7T*91O7-Wa>=6XbITCHh_|lD_5d(aoVD>z%sBa(~=dOdCU#hZ^4<$aQ5p?_` zCS4O&rb>Lxs<@^A;=TBSe$ia0KRXI}FnaI1x)U39@YBXSyGSg^jQ5jSn6R$8S=$C! z7n-KC5-H!Xpk)FmGd1)6MB&Ph6ns%g_MF#rlzb#C%Add4Vy=SP3)% zq4lr$9hN?#*kH6W;Xs;5(y|k(r>`SfMUGb5HpF;#|6rmDKtUf`s3NqeAG9)Df4q)g z;S!Kqxvsrs#PH401wVaWf_|hx|6c+wD~UFmjBU;sQ^8QcR0?nH6`UrHmg+vd`TyPbqO z=C21`o{c9~-tq=M27QL+#_er@I~#EL&+kUeQL@XhqI_!0kj@@#q3zkls zJ=hev?29U7jhx39DQ5ep@45)wY%fcF1{;IFKzfnZb^IrCg`J7Z3|NUmtvZT#3E|Tu zvQ`uKQa>X3I&4PK1zEb~x-5?%C6^6vy#Vs$noh?L{KErfg~4W+E+u1>`RmgUU0|O` zWc8*UIxBIs9|(~G)+9^bguMO=AY|3Cxh3W9`zFAT|P-<8mwzx*z>QxPX$p%Uw46 zpLwbMBU8iHg($GXqRKyy7;cPohK&qFo^ay5=qIM!ngVy22#{nQSR3FFUHmsYg^DbG z;g=L?v2z|+Sd5rVq(!pcLyHDHqUUd&J_#_eCsX^+F;vB&n?<|+c&IV&GbXpzaVOp6 zhLt9jBB;(nH7zux*4N+j-c)DfjY&d%aaeDBpKT9x;Z30TO%m8c>9c!6sRGn;C6&KK zf5jx=HUcX%ukO=4vKPO?zP zlC{D-mVQmtd`{!SL`#^;zD2e zQ}yZCm_l;xC@@C#qjnrKKFVC0Seb~XB{@&Orp<*or$(kJ_HH}(su1iyTmPLlrxB## z%ctS(ZdW*9l8Zm;mq-oicSdVijC0cr{`#7*PE_2-`0Dg z`b!hN*Ux3TJ}E0Z>-BOzYm z+~-<4BU-lgIV}(Rj#;m;Je(Z`qnQ&(K_~t=E zWQU8jeAwvw_d}Xu>J7{5vXSe5gdpb5O=FAY*hhv0-7+H!};dJm{h1g1jU&prbkP zjFhBBpH4n4>|u+qEFM@VEwa?+Vm2GBwO-;PN#E;n65BF{b1dU}0WlCvJl-XOoFhjv z@6zJ=QP$b@KT>EP^Xu(^xadwN4sctCG%WIx5Rt)oVV|#=SvSm<&6>6R(7rJ@O7gAy z>O}JGn?Z8qZFl3!*A$Tg=Q%`BA|w39?mQQ^%Sdh*sHaih6HH4#Ek851E%aSxR^=zX z3|-6n;wsPtww#Q^Dj0iYm|`99dKKsj3h ze>t^1n*9v{QTDHD0KTd4FQZ^UXBa!6O}GalQ1kO3(R1_Oj&%or{pQC@5ZQ+EJZ=D< z`Ar`7bAx%)R&MOn-^^oC|fxFYuw=bZAX2EiHj}uaQci%hO~tUxZm0>zHYl>M^IVk|`}IqiR-3RqutG zTEc3#&hO)*7~qhS07+Q%xk7~Jg?gv~ zUi2{NZ367SN*Qw#kf7J?;sC3Vr*Y1axSj3?eJ<$uBn^Q`wZdnqVRfl24fgQkeQfKF3kYa)z@ zA;R1SXJyAz-(27NE=OuFx$!G|iMg_3F_SZS({3HLIjYX(;XRX;CK-=Xlg{&_2k7A< z1LNMPx1e>3-9&WLVmHTdtSQ~|SvEqrDZ3gJ#EyS|bYG>!cHC!whslup6&dk8)^D z7eU}AzA>HMjv-vOxEoE^_0%8WOSHNuTa~Fx2MMI4R?zF==|BxVkzOe>G-^W6U%uLD z`d~&fQmgISK9rwa-S_!|ZIeNq9C$HG)Zw2@Xg>Z+E9@*vylH|~i+!B2=?h2_plYrF zvJR!GK&tKnsKou;;e7=0iV_$80%Jd@6C6MR{fBf8D1i(MD7^@{9~{qE?FafLzmGeB zoVe_`PLHFwZ#EIT{av&|7Gk7nLT?d76UpvgcfCIeqBC^^GciYmJ}mn>M7Cc`b1ui+ zZ$M65z?Iow*7Cu^(#al9f06?vR!0HGw+LXmokG{2^HaX<@q7%!cc~f72grO9u&)Lr zidOPewR~}jUo%lED9jOrPxIR_fcKE`i4USx^dOxHOK6)tXuVqHc}xxH4gOPIrHukt zy`X-4II&c7ZQi>J8;9*|Hum#5xecCDi6U!$X@a@gKhO<~=&PvHe3-xdUZlpS?%t!} z#odrPfBRCYv-zVb1Zew$cha7!s;I%qN(W^~Dgl5=<}-rM{FCSk*^*k*m`eRud~Qq& zejQ>MPp){{cRKlusD|Ozw-X-14$PNA;y&>f(Sv;6Zi5!8jh*3xUA~sRl6U!{jDzS+ zM+PG0w5kl+*{x)OeM;X$g_QsEh*GhO4~)F*9{%%KE&@agyD9qj#z#R754Df$%io=M z3TJ^?JqcQf*)4v@-#?S!;#zz8jQ%NWcDrA~1MpYt-BNL7M$E4}155N6^zi*}AWhyxn1Gi?7S6SzG) z-YRV8{Mo1ogfWw)tO$4t^gMEL)v>)!@Y4#))$ITNzxjpL`RSE)M;lG~#{77l*xx;4 MV5(oLd-3-F1KQxB6aWAK literal 0 HcmV?d00001 diff --git a/data/openstudio_standards_data/plug_loads_methodology.png b/data/openstudio_standards_data/plug_loads_methodology.png new file mode 100644 index 0000000000000000000000000000000000000000..75a05aae52c94a6fcbc47b44102108784ae1c75d GIT binary patch literal 64689 zcmX_`WmH>j8>MlIyIYY0#a&8qcXxMpC%8*-EAH-IT#FTVcXtgQChvT+<_F2iTAV=6 zd7gV;d+$UkDM+Fq5+XuCK%huViK#$9Kz#=vpMQY@KT;|rZiAm7T~#DSAZn+GPr)x> zEQRHTAs`y!k=~7A!LJdVq_kZjAW#SY`+*#BEH{IIc$bhC6ISywxcGqgGF|o9j%qa< zOADcjXgK6nFcq}?H*L!M5BTirvwyonI(gq@$1BzG1= z^|deCb&A*0#UGyNCu}f|7DJqq<&UrCh_ zhJYWAZ`uvOqWyF}C|$yk&Repz`bK@TJ_Q|}fkwNr7`q2%>VKwY9h_Mx;D+Fs=j0< znA;s}JICE!Tvt<2u{o7R&hT1&uP`RfyDoX>CfK5uJt^OD+Hg}P2qV_`&pU@96?terzfk5Jtt-R zefs|DN4LF#-8vFfzKs9g&fA+no`aXSy}7yBs;El1`f+sh%S}^zyY&|Qamj9bQBvz* z;>%!I%V4`Yks(5^A>Uaxi}AGb;WdAzJnJK0dm;Zb)c` z-1sx012nkoS6o}Hd~X>WEbZ;>9UQKpa3))$CK6S}Fd3Pc>zp=MS8)b5H}yTYU)`baIBq$;{RuXjJ-p&fL`V&Sz8< z6x`nKm+9;4A3bM8i6bH-D<~-N!#ilt?(HSj845W#^ziy4ENlzT%+1-vb%hHcU#xCy z$jHn00^JKiJ}z#Su$w2 z{P&NZm^ep5LIQjdG1jhki)ii$Cz%X;;x5(f?Sc0EjODYy-lK*@1G*V1TNeLaEW*c+QJKRBe zW$nvrmTh;p-$mtOOG`Ju^^*~XlE%uHQEe6-u{wL5t_W3C)%#UTLoUviNZK z@^f-1>Fk*#qBh=!nMqwwmHD~9`S_0$7uAd98M;T? zHsawCl2=;*bPR%=bHa|AB(iJ*0H|JnKYyv`Pt zVPGf|bKkM>W`9kS#x_P>H3f76y;r)TBmP{>}koh)aTYdpSsp+V^&-_#n?0c)0M;j6Nl&DCmE80UD(F zz4P^CGHYAV_u1@V#bSWQ;I|<<|H^u@$9G+mDDs->Of$?`>DOs4^x3#Lg;br``agfL zRl!3h2L(EcM8w%;&N%U9;FPhxtfl4Sp1CJFCg#{HJ~sB$?R9KyY@_R)?Blt~v8Q{A z;E3n&;OGZ$yO;M1J`v$}6@7go5|XU!q_cxP8Hg69%3z)bQiClfrrJDz;5QGNx0Qs-1CO36XF zV@HQd#^;HT43ER(xCe$^?d@Hi9aYS#%?$y8aWd*hCnuPMgrsD7zjJe?QM7Px5u`61 zH8?2PD!W8PbDX0?8`)6QzkMrH5sdxuqaFLZ?8-G3Rx$?0Y(~baKo6*1N1v3a%*n}# ziJrbp`GJyieU%pm1_rX*4&y7qd9HfBr&IK=Xk*3ma}-10+eth_e|-%D>W){LSC;y+ z>gv6w>E5YnW;0ck2echU21Z79alzNy<9sPmQ>;hRU>+Xcw-@+5GgX+0$kgCZ@ zSooZp1}qG0Q}FYK8k>Ls1}Vnj&JH#ysW?7@Oem+kl+=*i)WkU4R)Ue^W{+!KYik^` zlB+C|B$_!*;d4uQYej{%Q`jr(POhM*l$^|8R0>XdJ{pb0zAe#iHq+to@RpWGo-hg; zZb7ym!&CiH2xUfc)xkw0t-Lj4(^6zeKn@Nr&_NS3CT4O(M1-<-IT{o(G4;!sOVO{rzLH-uhIONL{(qM zvd4++&jf~|WXP>_Ubm?9Pq&i=v0 z>txHdSqm>8`~AbIYbzEU>uf6!xcxC!cEUZdaCCMhT(O6VBO4zrQB_=G2@@9D-r*hD zy}Z1RM}l>Hd3k(#sH(3@pITWZ`dQyFcAu=+`vnp4J1yUNZwr)YKfFA`8nh&4jiVS~eBH-=P^YD;xVzKjyY)|Fj;K2W7k$aZ4 zL417AcG>Wm8(sA$56_SWgaS{j$nWIz^qged3d*EpmEQNe_4i+*UfX>9eXWug_1 z-?Da-Cg$Hwv7wz^pN86t!&6cguCE1V&d)mvZ3I$cl)?H4UY~dcwjRBurk7oj^cLY{9|BGRDB|9~BXSW<$aI?QknZG8>Bl zA<)>_8o}s!R#D)%@A&Abi76vP`>2CK>ViLHHc~l8Rb5HRs=e+VI#}T20V!>GYwNT> zgeF^sD@sLsAhXoc%)-oKK5w-ASR71X_$lw|f)d^Bymo+0 zpk?zlS&B5()7GBk>dPOSX3mE`FcYkwA@-U;ZB5Inf~Oy~etJX_dxSvSL4*%2;ixe} zAsuTu=ic1-2{R)?E&lSIPgTr(pmp#fCN9dDOhpVMZ*;-??U~=}AtfYG9(Y=2sKQQC zn(TSCp_;Dl<@3_`aYEA>S790uYe+AZ`&i;= z;OOaK?S~yk&FJ-7EkybJ6>?95lJPYjX9EKR znuYVwgr!DbZf3D8 zHZTD~BVgT#Mnth}X=}qH2VC7x_u5$7n|qfN@Q2kJzr4M^ZT|LWHoP;M&3{yqfC6aY z|H9^gmEeqhzKKdv$QCWse@lPIyiVvljk4zH=0}e+n;wg(AfNO zyEm*G4if59Vz6UA+L3<9;bH2l4>Wtc>&q&hp{J*36RX2k$KWmH;^6#Sf5=Eh#i@aT zf3{+CfQia@h-AFxa-JTeAVXVg>%tPb6l|YN!gerW;3Enlctb7-fK3ZG zhcmiHXs?;}j8~+Mp4#y{2{#$5+7s}|ObVG1Wz*dNG(@Br76e-x8|6mgb};*EOiFPH~r-vG3-N-f4nA08junp}SyYB{-hK(ef$ zgY$#z;l4g2*^7P!J9cBVwQL&<4RuXZN_=DqkG>{L;8~-K#`*d=Hyj+?27gy~SJzlm zN5|35&aW_vdU$>uBBF?rz`v6U;+x3GsEyElaL5E~MmwV`A*wB{tz3M3k}*bTSv#N* zNhrWgkG|gK*t9f+o~p`R{Q!#xVOA#3Tp%rC*uupH@vro$DF+D@m`3FV8&39L!Em$s zdK&~g@9$8S2p9c-j-+<#Rc}xpjE&F;$?2#yLRl%DU|1JNhDS1L_x3QCFudT5)G8a< z+`aX4JbX=pKY%;CSZ-wEH)uQxcbKBjjVq!nZU8`Cm-^-9dB8QuR3Vesfx^>Mv6Ysw z(dqfy?rvfh5z*9CZ9Y*2v1T<&jm7|}4!802!s9u21BLWop2G(d;U*%UUB(*w6F!^4 z`EQ(z{PUBWNU?#qUl38h*UhA)rZyc~SX$fy-ru3Eus1`O#ZibGzzpi*Q7n-0W$+6g z9Xq|GSidz~tVd*Y^xu4ASBhdH+L+l{We5a%Ge^&KlwZnWKXl;$q(8Z~vn#4ZX@HL? zM(rW|mzRz%afb3>II?p8!AvH2`_<3H7wRt#E@?ljnY+>w0~nQ_a`>KPWq8#OGso%V zqDM!qHVCPcDYP=c#)KIfLb9b*;~(kQUsLVw$F(J$lvuUU_dhu}%;LyM3Mg2L{(k7z zM=Y%lGf<3ZVC3a9FqPuqBEf&TARtZ4g)$Nj{&q(qSbsd0YzYz;-peHdTu2JOAe-wd zX+0b+Z$mL&j73L}@9yp{Ew!F=JM7aWFmfpbeIGO_2%Aw$RA%K6EAqM|?v5yRRWqm+ zzKoPmX3$d0{(kqx-a{Jfh(iiT@?G6r;PjnDcxkF}36IwviLyIxZ=-^Pp*R5M>L|a- zFfn`n{DBBBlBu6$HFDfA8l#+aC&8itf+@Ps97B0SLM_~D?weGB6cnHu$X)vl1&me* z3^Y9P@$UOaH8hI3At*elTIdW!9sA%@P?2I1a8&K>8U0lxC67-|R$6Si`T70SO3uor zFY;Db73CC6u!0ap2M5(6NBDoTnRKXoHPtIcnZCWGZx0O(BU}VkR@y4FipzYP*}o#GvHV<4r^6BxC71UNZk&Gole z`mX!+jM#X~wIC|2PmelycA=rS4LV63Afyl_dz?XF5 z+RMwFV-M7oA9iZ9>p7bw3fZT)+IA``bfUvuMr&1-l^7-h$A^ajp8L4#AwDbk#6LRv zH4ge@{L#`TyCcL)N5nZ>+^OSx$&!gx!<(Wiaca64{TNnM9a&r+l=OCl#nh0KRh9Df zbPYY7+>S0h-90Uh*EicW)%BA#l}?VyLTisVoYN>Nix$q<(o(h8`28`A-0UuH=Pi5u zAt!iCe*5CGG7FN?09@~3zZ7t+g!cCvKY!E8mIEz3a8!MMJUvMbn00x4;4UFMaI9)c z#+D*3hF+bWpPTB>>LjuZ?E_CR6ft!pEM7kfK56J~3%`)h2Ha0fp?-%rL zcsa(;j!IvzCBPQq0UGD}v3i2TCL%*iocq@-MoRV)CF)b-9f zbI&cQVyLPQe`@SsulpNQPv*}Md;7~R0soK?QK^~ha_9$65{R3z*@Xo&%WEOw>Vm*P zAua-36rNC*-JcPm;dtp%7JtfZY;Ch9M+ygT|Mv0zE{u%|!OkThK#GqYEGiLpg4!yOs;0gOPTKM} zAo0T~uhy+ve%#GRgoc`hH+3}zi<|lcdIx?Vimp#aMN?dPTmq}b^wt&W@c4Y0#|8aS zO|jZvIW}GljKt?eV%ZJ8pQcF{#Mw7=K(H6&=y(exdAymO2eXJCzpK8acH-tWR9$1z+t4JKMDy1fI8u#b zhiRx9N<%~kx3>JNzshrSaVF=XOemWymd6HLK_;{0;D}|7S_YWA<3x5n?T|~b=Eiz; zMxo@Z;R<>?cwTQoBU4f%8cSNzL@Z2gMXByw?#CpHMGOuWX;G@Iul<063Yitt&C0Tp z0QSz(Zf5YpgSX0HhpU#BaPpo{c3N6{4^wxthMLv{9P~wcT3Ul3Pcg9sHl7YFquWPk z7A@0+HrX~r+OS@F1y{~ipohiZqC!)p#REkJ>6qA9Jjd!Um37=}>rMSD5u|of9@tfZ zP{j%im_RnZ3<0C4#@Gg`q@*P0NLK7}d3}vI5h2y@*ik{k{S!^)SVa+W$~8?$?i~$P z4HF4Xj>^4?xhoCsrY6|gVscu@Cb!K9$*7xdsACRK`b`~nuLh*I;-tT#6SujB@5sPAVAq_k2 z-Zix|HsPIvT#}rZ;ZC%Wh~i!5)d>9mJ)~t|b7R4<5>uJ%{ED&vCNcEIIiHN*=LbK( zES&df@F<#c8nm=OE3X}$a=hGVVuCQWD}TgXW^Hx#pAK)Mhe#DYdH#Z#7@ULX<5<-= z$$xgeTEa1t-;a;!qJ`A%=Wv=CMi-ldXYP>^g(f!ICBx$!lR*){gQNjkDeU~ z<98HaUFF>p0NvkTKenZjLG3E?{onovu=`s9XuJ#XJg>36##5Ju5eYI5zvdOwBD5g?KJe3%5E(1*;_^~n zUOvXN$KH*!(KtSKE2x$lxI@s~+6sJl=sAmf?eFg&7=VfxAP&GP7_qRh*y4#b1Lu;h zzDf@b^OC>#8S0apY^^IENM~V_yp}zTce@3OUQcJtO{TZT=Vr&>uO^0Uz2D6Ot5Odh zcb9KY?b0}V>Ffv+iqZz=cjx6Q%~AF{o00*tu7H@P&Up=KTyFykUw&O2-pMqAKjXZL z@CJj-cf>V}SB?%^dxJPbq&Wtk&!_ibrRwxMuFc9io|(Bh?QG1_)%6EKIwPK@cUcxR zG_dl)M^si4y1r8p{6g6i9~v&DR%E`G{pgG;`PE!#m?FM&e7uAJt5fMG@9{So0e!>vD@9zT(3(e01-|HWC zc1`CMBU>dTN9v=(_{8~RVr1vp+3%)xv|+#CaPaZboPFM$?gIhfCV?YW9ZV!*YFb`m zN=~ETIIOJ9(!ue%xYQg5HmshjPtMFtPDf`LIHh3Wfok#Z{unh(eEcKCFQoru|F|wv z(aFup*~#hb;%qpf-Q(jZKH$#V$%z(eb#?Xd?Cf@@pHh-0ec0l38K1GH2AsJI_ZM7U z8Ia~~8Sg4HynsN$R$8Hl%*2AI9cCB27q**L^M>9__RU1C5r8(hAKW@E;G`ROi3G*n z!2DwOLQ+CJgnti@MM+ar6I@{|*~rU-Rc+suj|N;0l^z|{Ov+2r9OoOI+G_3ZCxfvl zo>UOvaIIziTB2j+WhP;P+X9ZQpI_mTQPARl#clm@*L`=F0w;L$mL7_E0#CQMW#qRF z*+kse3yape>uVp-!4{U5K~+gfb7hK`*P8*@==eXms6T+Tl!Ljl9T=|G=m0 zat+O87H$>Q`CG4CffijoEf~|lk`*3tU*CbUJio+rO$ZG?;A;9F(cKj(7|?QI8XH}% z1iiW%8`m~Af^`{tWP_j|UhoWUIn;G(u7Ek6d(eZfu5;@Fr-3(P=*U@ZUP-|P?{9~QiysF&0QK)ZMt?#hJ#Jwy%fI8>{;O9+b;8?0|J!81< z4dp|&wSSea0NqLJ|CO>|mGi?{)UoVj>0!Bm)L&YE_(=Vx>NDx!8G>LN%N}0Y(7`q= zpjVVzTc=}F3mCka9^<-5?74gc=L^ouNG8vFSGc8?2L8g?BF@Ke08~_kWK~roMYEKL zhQe!yEs4*Bh&^I-qtmhEmJc{gVkPD2i(JJA+`vJ@#JyJ#N~i%o!VJ7 z|Hs9)J>4cRuD#^BzQt}pd|JAulgq99!>doIygXx`9|%V)EFzSg-R3m~b|}g8qHphw zo{YdRVI|~t%RmR6XeSFB6Z`yHHzScM12}^F;jgG_Xztv^rkS4Qz%T*D4(uR;EXb@* zDJ>*661DBna{|OGk_HY%Aqp;;P}3<=~JQd4*&eq)VJ{s@rVzN$1u zOUccBSzKO@o$Gaxn)Vx{q%hsXhKNsYs;bJ0(5M1e@&TX?e;b?e)xW7?*x3FE=pvx7 zFmbz8aB^`xO%jMp1+EsrnL5^r>;BRuIO*+k{RC0UnVnL)a9>kVeVd$`;`e>v7<|AZ zUtHugB1)AU8QOhfV3bDxZKxE<&cVtWMA6}Wj{4=lFyUkPQuaglAf_<>EtkmuS6}Xk zVs4D$5E$wMKrfn5EL#8SdOCm=2dfVlHI3IdwUqHIGBaN->*14#4+@LjD0>! z?Cea>I(7ZqUK(&kM@u{8?`>iE`EYs<){}QSE=W}78`rm~?!^7x0ec%83$mSq=m5*t z(UXuNQfza54;>w^8zb}YeOQO*oO(rs<#ajR8X>GF+o1711$Sd(UpZ|XsF}F}y7F=@bSuw7*jVi~#)c?rruOYHn*H@;einUJpPii}(}9DF@bx^$h3q?B^K7$QaczgW zlN1v>JwNx9-@dD=P7$zYJUr5tf-z|vw8H7`e_R_KrFRw-gt1;=Uo?B`Zq(UA5E=O{&@_e|lc)S~)>!lF-x5+L5`)Y>mzM7H6J%ZJ`>QW?Eo*j)W3-01JBPx8ymzusFA^J(z3Fi zZf2A^V$93rCAQzJ5>od^*{RFq;t zLB@;z4;$s9;nx?1MNLdN|M7WD;X?~^hXRVyx0d zl0=|1bRUyOuujqmarH7Xy5=_%FbGQj{Y&7i>&rz)YkLXL9PGjUS<_r^lwaGlEtO?iAj*rv`k^9Ky=TiRgyG&GFDL?Xb zIYr_PvW?RS&5Pjjc(Z_R~L#J^*w^y>;F?jrb^yG!V9U`LfJsiB4+jiaRejecAe%gJge zxuEM$_;h$RffQa`3*qC#S=!dK zaGjk;ViEC+seA(7NhDa1R;eY_Zs|C?n97ViVqtvxf+QEKCoD6@@)DRQTKSPOXlT;N zz`Pj^w@RecC}-%@%Fz74uyDd`@={oMCU!bxd<7IVYx+q=1Qd%7IfbMHC9Crd|tm1H;T8`Y3=-lT%d$8sU~+$f4VN`w+Qe}h=7Juf@KEgIjjV*WYN5cddbz$8c z)z@XvueokMppRnPuW@z@#-bxYa@_elVoB4QG;bCTHn;0taf=km7 zG`{5m$~3i7u`&rV*|fJitSMy>V^USD_25FP9gufz&zorj?VnBR;o)BJkCX$D_D!Cp zgyh5JMkYip6y%s=VtC0B$fZ?20n?iS{ahCfv#|5@4VD4zmrkReZS&snS1zlkZmX9* z{Tj;B6z~j5p-OZL`SaP$^M}6KW|ag24k9M)`Pc%9$@NCO@g+)WvOx-#(MVC){^V_= zlz#?|13JtcX>HmDm8U#14^`3_Y+6s6yldr*n?kFszaCLED#?XuyRe0P``40jr_{@9 zlp$H4GOsu7eCBKkLk8@;p0-lRzDC0VFeNx^fVttB=^kZ~S-pq$p+#d;sRc3Kvg}{v z6N|oK)Vf*fCCT$Z{c+j&|Nj`4JfQMDMH1ZiJ>y;Gj|ARpy!ehQlErsZs3mDZDyHWW z%0;p*2S4A%ddX*)B+Z9RNlubE*$Ez@&@twXuozP!U{?@WfjLh(SFk)2KHrvA1+*3Y zxJ$#$kf`Za=+=o|d`q@QrSt5Fde<00L@?FK{!-a@WBx#zb;hU3D*6+)21`$mJ1ZL} zK)vb_RT~>uKX=X<}8?E2?HvE2%~wVMyH^E#ocr6e`y2!q#i#s(^tTJHC2Qt`|S* zs+W~LuNU>*hl8)Rt-~w|?Y~RWIb&Nd>8x}Ule8uSkOZwh{@U)$eL=#seD8UD$kSK+ zMs{jR>JoS-6v&xuJkktfgmzg_@%rJLDcw?CUl1U|*P5$0Z7i5lRpN)aZvB849>bKKN^8wcqw}#tUbXyJ`ExC^)Tz4QU zrxxv3TfQ2!Hk;2uodFuDRyxp&1duFICdcNsW;L8&@Z^}E3}QX^>HjUGy9UWO-3VKL zJ`_WH^$)VF!%w1_Mn3!=KJ-@Qhjd^#4j@?^Alg9W9e|i;5zyflP-^GMV$->MKDc?< zz585~xxGT9u#)#3-piw7v&{zdVKG*BDUW-hn0^^+ZjTM>-EIJ2uGb$A4(HY=oEmyl z34Ep(8`f8lo)%5PY+dH;H{I)+qLG-^->KKD=RQsSZ=(SEaz9=E@Ip;ocmS@zS8)_n z)cHZ)=@-OD0(?Vy%>kC}Oe&mzd^9v~8uX$Z8g4FqJTXr8uI1IhG`EiXe;C=Lk4elL zZe=lTI`nj}?@Oy^g$0;bfoSIB+n=KNkF8=T%4D?>59`&1LKzP=?7sV|lgfg48sKyI z^bIQ}tG7}8D*iz7T)jfMgKl6u--3M%RHJ?4{Du;?3awsZ>VCLR-Q~M}H6~t+=9M+z zf`QS3+}p}U1Y9`@KIPwVeY=LQ($~fLw4;2}SvsrgvO}>m1q%yjy^|wU;k&ZLe*%($tkx&+u>QSW&aJIpidK zVeqBCSUqK9;l*0)NMPQcju&CbH@a@ zw=Lu0Syll*({_rNJso+RRUe-`bjU8JH7-#@ujRjUbAI{;P&l>;x>X&0t`SYIGQ9pf z*A8%U{OP)WgVk030XygrfS$ok|M>{}^Ntq@NEHwa-&*oUcCL+!B@#&C0zX8A?y?Yy zsJr;-U-kOQvCM$;&JW&9cCv3->nPg}*zew_u+hV|x-GqsE(!KkN88E5E^juV!8B0Y z@_Yd4uhqGabot3%mSqN>mt^_H?Nu(28UJy-!@SkW6RAwhRL+B zV{*aQ`Rzqm7?ER}IZR30f5namW~KRwoeQv5)5C?t>d_*}xsjF-Y}Rv0DF_WYXHaeq zveLP9+Qzh_P(h)=aLpbaL^e&T^OT~;gq3CIoC|0&${Jb826=f1gkYeOJENnG8x+1R zEzC~UsF|5MKIAqI){Rg!F5UWq1vTa4QcQ~S z#FZ+nRjCAHX9r#uaK|ohhaoNC*~|2s2@f!nN)#60ulu>q7rR|(=}FkLq6TV_e-vC{ z_@qg)seR?{+%#A}k$15G_2;~jT?2jW(>^*<)Lwe`5A)T*cUH!Sfc)dQ6+DSgHF>NB zoAjTuI=cm^R9b_`EaT&0|@Fpn zePy++M!mnwCxUfW{>8*3^!o1Mt`XfY`DR`M!4>arDZ^3bN@yhAQh6ZQkhM&GLe7{D^1EOPUQtcV)yhhZ?kC0DIX^xlCcD_y z`t8TD5w{FQ-7XMdkei0Sf32TJ*te)4{$K7M=+XpI9IQhhk$M?{nCf zcCN%;y>RIYY1}i5f|d>~>=oR2R#bCy(JzmoflAOt=PGy>Vp5+X%_~}++nYRECD9L$ zYgXJBZk(l(;eS^7Ew@nLbZ(A)b8-qlx`W#GivMT@7UHjGCsB=$mC65< z4zpeon^&?w53v^(c*1q}iG9;fjq`G5)b8GNw|xbSxRA%SOL;%@7;NLyzls3ZuFJQ1 zyahke+_hGILW_eBsiYDt_AL{xfv^zze|P{`FQreTju)}VSE%1naeqPlK7c(7fQMPj zTduWyhY|ow$CO~obAPnhbGt=x@gGPLL zZN)e3Q@#RdjCIb>Wsur#>Fc#Dv+W7!TxWx(^HLEQzCYjIABj4T=RL4b z7XHvcI}fS0e-Pm-5ZhnKm~V>c*h>TiO=apJ9dF+0*pqCVRL}0&oCj`hY?|ibs$^6L zLrx9Ctrdolpxjh^k99>><9xbkm2gLB$Crt&S@_vfW_J%ExV+TD-x*4oSg8^`ZX5av z274^jUAh`r&T;aZz&X=@f`<)IDL&?y(=R&GE#Il>`0UjtD%FArAr|_5dk@A72e1w3 z9{qY%8C5?)@%RV9m6SJ2kLw;y%F#Efxapptq3p4L_vpZ(tmwfT_R`Vb`tuwlbF6Sa z-+gP>MX-@S*wO=LA~bZa?KOw)UcstF17gF|G-48Vpl{>+B_v^x0nvD`PyJG7?@E2* z8$I|h9?#B_=Qo0N%%fw23-NOx{H{)^Jyds-6uzok4#OR+fOVE1dk*pNxl10C0V{bE z+YBG;@G-GMvpz@6*FdjpxAxj^IsTMazri{dG+P-H+wzf#NgP~q)Ny#!0VS?x?lb2U zn@L+yDtP)mXGR@dSmoP~G#~OX&8^$!NbE`^G;eA2t~&IXh8q|-EUA>a;nmKs=xf06 zOcGXwSE{doP{OniM*gjyaqKWX*hH6|(U%01(D*#2`IdU3oUlU^R49jtJ|xUy7=1yu z0T(bnu(k4vbRT96ZfNgDZu8-ERh4EI*eTxx7x!>>nKdk^FkmOZc(kPR_$>XATEfvh zS7;7Afu5(>@@T3YANrp~5jUCEnWF(vO2ZQs0S2AlipI*VfBDr5`)GgNf08zIhmJ1h z{uQ8*gf;pa!k444KCHN`T7nnD-3UquB{PajxjbHG59q}%fnM#U5{Df&`zRcO@-JuE zKQ0+B`5AyeZB+HTU0c?p^VyR!9n24AkJQikP15O2g|Zxnw##A1)Aj#=gGhSiv|e}m zBlU4Zko==x`0YNYlt?!-0Bi^U8Kph|N=vVcJt@Q{EAk>W--@3K*!{O#cU9+QaRr-% zSC=HSz6H2~*OS9(fG7X`6Klt0Wk3^m@d}yj_T0zQWAkE&*%0 zQxqUA{%3u&FV)UU5d$aQLrj<|iOfiuT=^8`LSbJ|l(SY;--B>!CbUN+Jv|OF?XwJ? zdq7REBgb6({qkjU1$y4nhp8LO*vFo*R6qRdw+#QjP~T;aAOEhpx5$&Df1jCQBEx2Y zUDhwPE^gr@aF~-y#!bb~ofMOI;0pe-$ko)@#>4FHxzpcpe$8YiLcnk%uq@?2%+h}K zSy-Syd?G7Z~yxCfiW^g#NA@0k*;0I?T`Wd^vIJD9avi(8bpz zY9H%^Io@McqwisDXZPCmBNJ(hm}!O7*;vLHskJmkB2Xdy-o0S+-3d++CS7>Ph+Bo^ zU6aI7?iT4X-x1>W9qI%fk_nOw$B+N!UOsZ_+f1BYr0{~+e7*r6g7{x!4o#`*(|Y-r z9h*WLqVTclA_E>>z&~ zTXGp|d1aJE|9J*d!9wkKNMG-_!3%8WR&B6<9_A;f8VQtQ<=+ty-QG+f7wgx!@1h~uQ4c_Ei(DltkKQt7taV?EIxZhFn0luD_d>+ zMLV_^Uxi#Mw@RlSBly{LWvW#aX~vS86$977Z0&8G#F|H|11oreeT zXyroEBU>5@`@PRxq-ioOv<~O-VEgAo?Li)M>`ZXdC3l|l3$DmNyV5?3h|~1cqk7(( zLQLLXVgbfBlca;6M|O`yIn);f7aZSj_tkiN)%)le3hR=z#ubknzU2MpZm(9y$S{A2 z5&D>wdg86O^t5F^9lqwmGtby(rUWN9@*PgSG^PP6KFB>4uPu)khO6N1(5)SN3dsLI zOuc1P9BUV?OMn1DgNNYm5+rB?!QI^n?(QDk-QC^YgS)%CyEPKz*8a}8XB-CqySr*t zy-VhNmXDXuuXgp9M{touv(txF{q_`4t+S7Pgx+WVDZ*VFoB|)6Nk#j-Uu;?)IQK36 zb67aT>GrV^s-4@bjeX=J9ACO{3 zQOP;(_`d4BP+~=XtmCA)aF?5BO|-T zsg`*Ot;XoGNLLI}SCi6RUq{)-lv7!^8?j_>T&Td(@SKhfT~ z^+Eb}KD8hQ2*@C!CPi+lFQt>OkVGyT_y+1%ls*LGw;U|m-BwP#4s<$44S=m_GxE{_fNF%89H@~DmpBT?jyHkVD$7Kj)kZq8hJCnHStCG-Y zc|Bkt87CmZ$zo}aV#!qm#!ANR59h>-)eV2%$URQpQ=NKP~HN3SOpq2?rW;HfHY!O*eP`jh{~b zEeig?9q`e1_nk58&bmREr8IH;Z~__ySI+HL7$1=nb-F+x0h03N`B%wN60NCcQlJar z*gR)PdZp^DaTQ1Q_Bs~?Dt^YVDgFU+E>tNEM_ON9WtNnk9lL6cL?Qq;SvH(j@mR30 zo=Sgg&2`NvxX?Tp=wHm}4ROAAo0xdCll(QSBg-dQ-uVCTZSFFZ$$PH|n9*kcbtW={ zkD}9$;){&b6+4N?;6kO+bB@L=| zH`PJb-;;ITx=mSZIjpgES{add@bhYO#yK>bz92U|*RSNE^>S;^(i#>ePgmS&UZ-w4 zc+h&EOw;vMhh`;DJ!h?f!Op4KeKL|(k`hmP{*!bd@&BUr-uxUVjBEHgwNdCqW>u5v z8J$i|Y`2hb%ToEHy>ULil&mLA7RZE1Hm5Y|67Gb_Ng&W;SjIjFPSez9I66mt7_MCd z;ib#U{w8?PFAHYjT`}*n($W59(nsL+ds)V%FRW=k1+B5Z-aw`%$KkhZu>QY!glX*I z;v4>sU@LMS1cZl9nm0?am&FH-bnm5m^wgd23u2YuLx&C2`~NVac|h=#KbD!fEZtk# z-2CJ$)g0nu!#p15AwmT-#8BCU9`jw`wTqXLx(u#?u`RXQ|3VLVYhD`m=wI-y(Y-ZF zF9_S7Yz;QoV2x_Mbayd4D6~G=Nc!yNyiNUYVxaY60juoeQ_MKs(e`ID0+e34nx8w_ zrg!woe=|ex*U?`BN0;Qb8ZKJlS5yeJg!}>qX??OdKK+-^C}`?pzU9*eaaoDpMFxvc z3O5E1G{i>XRf5V)+SRCGDdYTsllLajyRZ!N1~k?Rb67^PaH=9g`lD4%r|qL*MW?hL zvVLD)U+yE<6k;|31?X zv>KIu+3mA-7&H%3k4@sxs{CEx*vLbl%Rq_LN@cI(O?j?vQO0?0wJ7>8(y<{8oo@KQ zR6r*b1nYq-`p+SFEk1Zn5xZypF0D)_+dZ{|&90@{zJbN1WKG+^Oc0Qqq_y@t9XDPfg-anNT!(9N$| z(IP-fqR=M@43U)-k~4w&aISzd?}oj26X*GLi;e2eLCdOy z2k-K9DvHH8Lyq|mAnCQVvRYU$bK>#>l!%g&l3ty;c>*lFy!tY{Txl5@zk?=XqcZ^6 zFnut^@xpR_y@K|uMd<0_ukG8N_e`kuz|L}#rSj5C98|n^ia5#;@%$q#9n4){KiG!IUag+LlYP$vURFU z^M|?fKMiN@)5cg{#kaS-7AaM%{|tIITdfE{ufjK`zCK++okT%1O%nkj5di@KH$5G| zcK{}HIKTw)@DMa7p*6j^xw*W&e0W&I=^clRg7WVlETYIBu2tY%LwkF^O7g<|A^_=0 z5w;(swMNewoC#0~;e zYJ34^U^P#sZFV;L%fLG(V2kBcO77&1=a}!kK4WOhkmsq6^G5?Gbp`d025Rc@Z`jKP zaB-WCr%dPIpV1hFtj2>^S6AWi(4CmzoF6?<%Jw|R%tiF!w+{rR@@Mue>lf$KxyKVb z=8eJrULuC3UfzcRRV1{`6|Ca5YYSg@cT|$&56vGd3OU#px7epAFiWl-YpN$?kifRE z-U&B9%=C#rSu-?pmJa@@06L_b@LxQ9V+M*=P5EqcO6b^#iK!qShlfUfuv6qUk}>x8 zbuyEd(y{T*4waM8=azC5bFr)pt&FI}gu)C73hWKRzCr8jkN)S?taok3 zZ}qyii3<^RGwW}bZ(F>l{^L6TuTvXo80Oyy z6zFN@!keCV(ncf3GvJ9#T&_2B|0j=sPVkcbA$(d%Sh(>f?oZM}&6)Am$6zi8%{KT_ z&9+nv4-0jHFRo7?i1S|{fV0*BVf)_Dl)1UNFb1@_sVNZ?px-JM1GM)P9bH{JgkP0( za*26ZdCebFT2nU_xaKFyo=l$khLGW7u2 zdS&DIeW7~=SE251jyk@DUw^qy@}8CJe{J6{GiF2^Yd$6qj+fI81KJmxkN!KtkLNr} zT}tn}>_=O>Hr!T;b$TxvX)2;@%a;0I)T2kB@yulMWR zpWH}aAkfjb<8g6+l$P^XQU=2ez`it=!{7cUrJW^f=j|OrAjjPSv>jV<)ghyyp&Z{$ zksMu=3#qiS`6yA?wyS;hiLj6kX!F`f$(eFKd}H47MN3ZPP+S;cVW&ypsmiGG=!1u% zCF3#mP@*uLb{BKH1UuIOW#4Bo9ovHNv%B;O+nJSnoNYSALs~}4aOunF`zV_0q8t(! zA`jpEj=n42({IY7U`YPq83%{roEVYps9!|Mhzy~dl9vjC|8qCcNKN4{l0iKV-kMXD zk5C-eqc&1LO8qYijM`w+pU;avy5G-2b>D~jtKa8T%E39sBON{k-f1@XR{F3F<`%s? zSTbb;<*yy0g)~0*PbbsUU-j{lGc)mdVE6?J6~Ynu1Dm5imQ(Jf2db(r8}1_t4~*;q za8)dhtf{$q7*z?=j~^>@Yp`VFdKY_7pHMh#!WDjEXWcG~O{rEyAU7QWxwCR|=Y*nZZOu+gw}A zPD#*GEk@rsK08A}ipFru2_GWpfn`)IqF}AVdQW)v(x2K9@;}JHi(>x^jSMHn%ETgy z9%+ASbbVG!`PQ?<@Nw)z-PE1xd?cElDKZbOO0Cy6%4OPIT*^+_#mT6wM08wPW76DS zTT4YbK4!2e_j!MNG^g>bZjSXtJm_^CIQ3prfN`aPK9)I#5|vEIK)}^f!gjdn9Uw0T zO<(b22-Ng!EwujR{+yj(%T&w^63;}7_7Oyy7{z-fz#~0zNW~9|2#JX+Sf=(OkKC=> z9~6nLRMh4$sfhYtul`t?+3b)-OqfpHt&<>;m*bFCx!n^d~zy@ zN85|bl;(+!X$(-NcaI3a5)csci3nc>iwc1sQ9`J?VykU(Y*ot2%zeqP`O6nR!v-H7 z9$;c8e?2}wCu5_h&u=M6P^tn)O>(+Dlji3$gMGj1>!ZT>%L~OeH#Qa*6f7>`8era_ zqoYGaYiO%zl+BvbfOxzHhbV=V0io}}Kw%X@)^;Qn!o~S{9K8%G3e|4Bk;#!pn<64H zJ^kDk9}_+4*xXogTboD+Awc~D5Hql9VV2ktAa2r!%CwBM-u=@*1*^ULMYk1+o2&UJ zhxwsFmA~F&5;OvsP2NvaT$b(`Q_jB*anR&WypLN4~Y?oh;r$HT)E& zzzw`S46CD{@%(I0AkEf^aXQ(5_1WWi$6i)i)97+BCQ6=A`sYN0^8F&_*A2Y+My364 z5_6R43lU>w+n;aMYedalNH4%wd8E^JbzL=vU*cCC&9hB#X=(G2kI$C{8_%pBA_G?z zQmIXyeLq#_G4Zwm#|1r)8tQiWn6$2SDU`r(D9_v7yhGfw;4AaPq6gS?*=%Vp{ zs4&62EfDTMb0)6#<{d#w*0h#QV4OPFxdn`Y1lr!>+8OOE8c8Q89DPqLbKY#0R50JO zV@=`?$3s(G2bhygBPewF&p~B>@tC!KeQdz(?wnO>UwFPv_c+gP94sr7i)IUdb4aX( zon6A!+5p|q3t@bNLy7KR`#KYcrYzu@*OH$Yo0^)<_%?_vOh|y5n2=Fd*OnF&W5`M@ zVJ}hEL$y&?URD*QOvMqM)I4x)lb829D7essY5IO#N=gdv8VXK$sDF3P(a9+=P;^_s z$;m}jcnFZp0`w>m5n<9FKUsIX)bhe}%F0fIQL=?ZhGK^3m}dYf^4s|M_@a`^zyKvv z(wkQ)U57ZW%Y$wK}#ETpNW8 z#3g^VwZ50c&F@Sn)6in`5Cs=e-zHDkwRpk4)ue-Q{kD8QE=S6PYzqyb-(q3cC=YhJ zmsK;=iWs?FZlS1#DHcn3I%$s%#LND8OT{eoWy-1ar@otDZ77=Bj%d+u9$L&Xh2Vn^xql@t##LAy5GQXNo^7z?Gc~@30txIMKadtULIT_>3qSbu&7QQYLDG-JcVy(myTLPNK=2tc+8rxxc}E?o$ilAM| z^G72zFUqwqD`&8a$wgs&Ng9Pm3Jxhn$DNgSIh~d;D;^dwi-e4*1!(H_RNc*K?DxKy z^uypv%o?w;72?z?yy4W2Z7jHosbspb=mK}O2&pVWO4!uUm(qU#f$a3?Fa;I6ZdzSg zGp0f+QY7v>CWrnXo$_7m0qj4ZYiE}|cLU|t?tIJh4tlWK4;lq6dR%h4{ll7*bV&QM zamu@t@bpXR)B_WJJH|5(x<-qI#kLclwZXGdBmO!|mqOt+WtIC=!f7og@NkFOjYRV? zxb}6xwjyrRj}gX0Ppj|X1zx)3-}}vbYuz%Gp3>61vGE~XbI@_`E(tsr7gy8sGG~Y) znW@uk^eI<++wNX`QZl&@>hQ1Dy}IpVA;9{P9}yAJ*6QY~mLq9zZ*Eo!Xo)3=B6E1~ zV(CV7@bK|ztEcBr?mvC{CDiWjE+8$JoRy`nqf=W~x4W|=tmkDwN=FBn0iqaM+uHm= zPoO$d;R(Qw0>Ddi^g4U^3H$2_f5F23JHbh%3OGDWI@-=cw5gzEIheHp1NrmjxHzL>hVDE zW_(;f{#NhjQ~yJb-CPN?P-FqS_!H+CXn`JcMTY^InAbWK^?gmyJ%h8n4!C`RpmhAf zx2&S1f||uR9{CB2+M!!My~$qIo7w9#^?e=#^>R!5d&gL8aqeDp^ZK~-{Px|Wl0&8X zYYw7L64waO?Z;zB(afA>YH&?Rm@i%ui`q?joQ`6D+<|3V{>~&q4?z>wTp^MZp_LWJ zgO>U^&Nn>Z{imbJa<+SUX)X83MK%Ojk=s%o>X5L|$$ z5P+uHp%)es*(0v3tW;Jq1x!_l4=}wXAFHeG3JPT;yuTFH6Jui5rm@83yD^ILX<3yX@RrDRSWAHo8l$@HWwGa&cBe)}>pF>&VT-s+uSTU%MF z9gqtoelcGv%mFEcxvr;kwud)b-|H^>Hb`@Che_J5?1o?5HL+UP?<+T3m!cLTt8IZmx$B#r7n6OONMw8%|$d zG(RK;!=@))S)Qnjj1Fofv{e-HzO#2qB27$9l`5G}3kdN!_fC|Rl{I-PBDcAo|C*`- zFZ>~S0(ls~Xxn|~VyCBo3tTH2NoCszQ4Dw@3;5@>v`-j?E8lWTH!!0``;A3OSF2d+ zbJZ;xsoao;k$HBLsfAc_`Zv^_E5EyjMO_o6LfK{sMn+$*JN!fr*?rh}6?cn%%`uyy zD_D=gh#VQGU$gGrVADEO-&9L#8zmD<#ChrFq~al%A!s)o02rLC+=H->&`;o6-R;yy zr|A|CO>;#fTPLIbW_mHDe^^T9918_lNR3*i7z&=gJ zjgJh6xOjFJh$l!O>gOdXs71^l$a7o#iRsm@o5)_^i4gFdvo0+!CnRNYGINQ1yZY6F z->XfUPW4YDPE?dXCS)|=$PRhxs*j99)H_tG2q-5dlQ#8n*(^~`T!PL9XlHgSn=bT0 z0r1le!CQ5ash!~v5Z_s_^8N3>ue@~qCjVKx4AGPWMn1Ic&|f{ z16P*=Jf3tU=2Pvvb;o?JuA`~Gsg|0S-E?!`JHC55`+D2Ezn<{lwXo1U!%e4*cysB= z>fB74i9?ib!8QU4Q3nTF;Jkf#T6&-E?-$aKt;?w?DUtgUkW-|op(!aLkvJNsCJb3B z7BLtEK%>VaEPX!y?(Cp%UCCi37Zs)Q6~)A+W}3ObAW0~j(u7M&D8|nL=I}8ZR)FaW z7+F_VS^-YPUle!U;w1~#L~(KI%1W!bxmn2(fQ1ae2zq*Q!C;wz0UF~Rf&9==Mc+T? zA1U92B_+d6;jFlS{@h%bl3mjvHz$oaA|ow~WI*sRWRrk+pvi+Ym~Is_#E5mO$`~T) z&KPP#<6K}q;dv#f9V&}Yg8G59BRp$#Eewn`c51o{Ie!!kIZh${yNg)%$I4RANK7r! zE4Q>UlwXvfs#iu=DJ_1ESecwq@?KdMME{MURT;++#`x8vsUSKK*GZmt&TG~m2Z$V? zuK++mwS+NDNQjBWb!~_uz&7UQ1h|AKUyyWlw}6^7EG(>t5jYY*M?AVge+<}*S8>e?_9 z3kx?dZ*5c4hxU&*Y4+LTeyjA%tU0i!!)+e-qPx10#vXSy(as~ zNsaKs^61gWQMIr~BLdzOyy}S=6if1&*wg-lT@!oP^e%e1SaP4P6;ovM@|Id4(VS7brpAO+_nN;p*ueMqkjNMM_6U%S37v>R{*+fzR(*rB$(1g3`B?Yu%S} zx;6p!G`aUkOLP0$%*x3bc8$TR8BwH6@z5t4x`eFb`T0cvl?4T1c7oHWL60VFq`X=i zP70Sz!NpZoEcyb$;NQqB zM|f)s3*7JDA>)OD4i66jv*~u&*}@LsJ6&IYZB;+%3|;y?<+-#;Rn)c(gPx6?k*TYQ z75a7bQ~5Q{bD>csr2Tw9Da;p-BJM94G1;NAD&)eIWYzj(8P$yB3c?5WYBGuHGG3g7 z6HQl)>Dh*9C!Wi5`pZ{l*3!r}^dp!H8J|6-qw6K>N8^60y2!#(9vy*^{fLQ?=%v4m zh$l8K@Qt*@?NVSF!RJH=kaGD#}Vd9}@E2iCPZD%F!=ufLGUp&nC zjq|yX0;{kqlt)2X@=&SDe@`&6ku6`*fTVa_h!Mr3BtxBh*>20|3xJ zfxKt!lFu;iP@(*S%4--1qDlN7DFs2lwLYt%sEGZQ>g@zCE9Sm7)z2?wxg}}wCs$-}H?b(Bwma4=d1!8rjDku(pxRicwHUD;9&``->Z6tfyz|H1Qe$6HUgz zkj1Z}B2y}XbX}3s)gh;*l#r5AS6?5#r=UXN_MDmNE7!l?asPdDGYgtbdV=2il3;-i zn1(WLLO~m>u5yQk+j)+AqcB9(=Jq&GNf!a5%bv-@na$On)AOFwhyi8e@)EiocP?>b z&S=lX1C>IVqgq3C>%>T3x>|TOBUfV1bq(%iH6C(4gzPGCy2t!ac$T;95pbL~8hFDF_#iwm)8$(~QE11h2NOrLStt-&mmw#?~cYArYhpA^v zYp0Xz?*s_>RcR^dBF^o~_U@&GO3^Ztoa9Tkrk{2fgg6y8tka|Cx9h|EB~3a@Gi$wky%da0El66rGnz1pd0k$1$+Gxdj#`w794c6_` zlaQm7mW~dwE7Q-PQPFX_aw+M_vI-LB?zUpC1_mrxT)qV=$(Wd!P-Ho9DZ%Yfzuny3 zDJlN*Du?w!Q*pJoKm{xG|MA7~wZcxG=nsg^;PAB}VeVFbcPVIXeGUx`Rn6TCeB5tb zuJ87)`RP*g)50!sg@#75B}*nweUenys8zXi&W%nzNz;gwNU{P_1t-eQ32eI-08+VS zxj7j8xPuh5i3SZnx~Fl?l4yqMtgmoz zgZl@E_+0Nfnrm`ugucuoMj-EI?qgz_o0ny1Y3Vjx>%@d)0oxt=Mt!(dovnf`Y@6Tf|J8^d2p z^GPg?TO(5oK*gO>EiA$%Bro|q_s_0Au5aRd<9>J40x)})7rH?U zPViVC0S7Jn(PbwrI7-H)t9uA>&(*7Cx$phNYB8`CKdDG%yMVf(Qi}nSMHVpm1kL|5=!g-v~fE+1h^f z%@u%$Z&f;4_w@PL-rpy?L|Cy^56G{tsey2mzuVu(h?J3%3XANltK(wkqR=VNXE?=h z`RrGil+^SG@}OJ^+&Z#6T_Q)uOycl*D_*`37!;`at{^)7_bw_q=B>d zrT>uZ^g9RF<0YTa4p(a%jbyk7jK^3x8^;e;ze(~we^J>C?T!51-+8;g?IO?=6|(@! z^u6OCIoT5obb_)umClxFMOnGs-SzCe%1#(&x#Sxp)F+g63PQe*>tU+t$+4y8+Qw87 zhugclySsG|NRegsYQ0mGgM$unz4y)icD%}^gpY`WgNdv_P5EVfv#Y*(P2xcp5MVYa z=T|z|I!A?tJ2*W;444ICRn~QK>%xI8o!Bf{l~rNdt2ACoix)u6(INafxAu_=>c5`_ zClQE!nb_zzHa0ZhOQ>8&0>*0K=l!~N2aM)6_(np>qWPoVyk-l1Gj!qAq?n48W&Zej z%GenhDQjiy2Dq7*X%#Z~TyNWXwBLsyWMD-q2zeI^(sb34U>CqO#wvQZJSeo$opWlW zbFQXH=>eH&X@gd{PLlA^wOhc zqW2y-xHy3*=W)M9EG84ly+(keqf^P7zL9weg1wfpzq{)p@J#N=^HfEVrTM|iw(fIH z#X^ZY1ULRI6|b_Qa!?a(8OoK%{gqW$T?m~NJzpW;&JKB!p&>CP1Me$_mQG=h$#O$mr-e=vbL4xOiyFdYeu%EFw>g0h>qU^y1N%8+*NJ*<#_8z1 zfSnck^Cz3Ck}0qrV{mYAl$OTa;tZJA0E=H}X=qecR7cbm6_=KlidB;Rs5k=Mo}W1s z=B2ELo!q^E0w9ZU1^|R)%IGR9qvPXCW-6f20WH(^iVm$@rVk&K3!sXyB|$(4?-!M^ z!;xmE9BW0(%+{Sgd$=za$Uiyx;RAhK=ypZxlO_56QQU9NOZ4r zR(W?bKUXG~1EOH#QY7)8|G)|Rhs(NTEhPoRB|ya0;q8jELB+4MDRFUh?uq<`S` zihL5?COMCnz;>T(-oEIY>suJJQ(UBNSbAPJFrL1o$(aMJD2ffCEFmE_yGsY*&g1qd zguweRzl1_1Ax8|k02A=j3QI=K@5Zq4Rd-P4Blr&Z2Ot#8EScIHhpJd4d3lh31RG%9 zF1TH8sw#L;dXrBdsg%htvvk4=`lqk20~dtHiWp;bqd_aq%~0>%KBNz;HibI>Y($|h zMA6@d{uLkD)(F1PM7uV&Y3t%2)*Al1YFU~cAD40qgb`Ehrvx_V5YL>QfjT|me8rEw zz5w78i0fTmy+xOMo`XHOvaj^ zW@%$X5C$0F`h560b~CWzB~$&NF07In+O&0YurX!zsk{)hb38TnlTTD1AAU7f- z$1p6MioC~zB%ojqDG!heSTZ4}7=I{;sR>a?7iVUfU0`Kjr*~{9=}#~mjqa!8sXn{z zstNv8DT7i5?{Lea=#*HN+A|rp`==u!;e1}Gip1aO9pOk7m;i^M_n_$x#caJ|x5`$V zfS#Lv5EqQ>^3~)1ep}LXf|!z#ohxCk{GsWtC6W4L(UB&QI6u3UoXXjqt}*W8;y>YJr{06tz$=m-uCeDx<9EfsiOiOr)V& z-3O(Zl(cOxJucHlc#c~6P4hb&+d>;)+xpSWW0SfA2|P!NScjNEQ;Fv7Uv|O9zYb#F z7EWNP&G}&ebkGx#LBo`}!-jFO9Wdf$p>C+8Qp89e2?8bc?VI6wspU~RU?_+a& z=-bNtvK9+kQkac+t*2*&d`$A4^&4Dl%zhh{`LxuV<#g&hSQm6JFmcZZ+S+xXjOexB z=sB4iI2(Fn^rwAp=FbdRE{R*GqtQ)0w_%^Jl0o{zHRqoRWhEjJTfbq7mNn(!%D7Bw zTd0+)nwBkXvk=IM*ioIIE3AvTeHNco!ola9m8yI4m{Mcn=5Als>`+&1VVvXAl5bE@ zk4|uLdTL`u|KQ!VsnEQ!U^~54cGH-CnT+^Dl8Y4lw*`(iot8Ge{Q7o~xumA0DWFX# zn4yxf+PX5%&vID!CnQPeI8YfNScDhkoyEoo`BJDfsT`^3P-(?(%?Biq(Xc9a0lNoA z#l&iwgkY+a#6U{Di3RJukP`G(bnzyBhf=)#voC0+OwXYbg3EDSvS;^r#1E2QEJh+S zcC9Rb3b7a`uKbQv3#>zsbrsOB%WFh=eyXKrrk$UpoSvkeo)NHF5%hRXOmO}u5>vSZ zH=R4-Jji>;4|R7X{1++E8e|j{dzk<*AK35W=qM(up7MR0l8Q>m=tY_q*jfcp$%_^w zy5I;Rdh~>5JpMg}EnOrGkOS)&{>^gxK_q=Q9T^_3s!a5T6wcJhtn$&b9k|zp;dFBY zmZa&$NmL>uB=ahg%=PyE7Wj>pHNCz4b-1`PKFr10+0E^FINBMY=drNVySsasNb{}8 z(}dsM7EI*=Ts`Q|!D)3JaSUi4WIje-6qKOWx`u1uh}q47D`8=qjzuF>jY$k*nO7o`;~CoSuk6M^OP0C$EZjLULvjEBkDuztKV=`yDV-;OXcr92uU@iF>VB zzfTBS4ZA1|&F?hoAQX1&zZLr6^t-cqdRV^u&Rig5-7tUg*gT=K&sH#`&Iy`csXZzl z^Ec>oRZP478YE>>;i>S@m_>aJhr|hBzcMob0#JxH^H_lz`XBNN-eLnLV*hH+6?H( zbas#ji}0ZDrW_p}9_^=nPzvXUP(sBhlD_RshkryWB_|dd86qPhFD@+P!j^DSP$X&p zQuXqBTU+H8vSKU@AIdTmMm*#hRSL5n-@P|1B2y_(OqWDo4O2j2U&0W!46c>YErsM6 z^jJ%1O)dP)DPB7Rn&7%79iA%gQpk)?b98LL#3z7nOV~GIUsOq;zUvkI@dX z;MS#+RWF#SEzRXaXp@6%0?BxKjraZaO>YYD1n68^k7h(58_=^%&nfsc)Td-&RL_<4 zYpG+l+VT>DYd$}O>f-_;=AEjxug%{64Z4-b20d9TK zUGlChJ*;US`Fh5;YWyzADhaS_rQ+k`f#&@aYrxTA0X8hKQ^psE)!RwgNmKJ5z)c$+ zm2i@-EUK$3FW3C`2O21Vfx@)tFezzK<#sz0P#HjA_N%HcNiqIuK0QNfZ|7DjXDFXO zImN~*xPq#*v7BFA+|ibv8c$L+wbc!f?b|hHRhE{XJvv!jT>3=Qx%t<8Hz_jx9bfsY zRjiN+KnpW7aQ= zF6&(fzohk^-}Ccj8+$o<8<*7<;o+^O;Ok`LS}mF2pc+z4;%^OXy0wVAT}(8Xr|&zVY&@6ElnLY^^7z= zZU2xiC0C7J<-<99;#hT=xay?arGPJLLBe{@ULJeE=EtEKG#T9n>Zk?=d;C{{Bz>_04Kx87R#6@KHOZ5_?8l0U z@o4aFbpqyr8LdQKuYhA>S(dSvxqw!pL~4ANLQEosL3A0DiCsl?T|<#xf? zgsSkWoyV@HEtnONaI=-x6+pO{6f_%E6qD2cur{*aKEB=Dt>1Pqko8jN*VnE8u~=Ps z-oKSMe6Mhxs-2dtmO}82@cTDHR&9DHX3|=z#)#40WSvSiER8~q(a+sF3_i|1`!WOr_ZLG>!VZU`tJFFp_;sm~zOr9Y_tf?k6t`AOtQJ#%xL z^?R`NFThi8?=w_+m^K&?;}?|7F%g60QAMH61pX^}#-a#?FU*O9GxDW{JI>Gw3$7>e z$D)$uI3h{|dxZ=VLj-si+HxXV2Fcm^+gVQ1gDbA+vP5YmacYEX56xhZhbqeT^6@0Foe;2Y3k-t*VKuNPnzE{ z=2=zO`gUeSbM3v^hs6H0zC4#g(4I%XFbGqn`TEvQ-ihHM*Fx`)|AM@SX`&sR+f`p{ zQqb*Cqq(MIllW3wQ`NW3N#kWc+|fn>9NngnnZ;vuSBV?H}zfI1S_va zyydt}-5fOPzM}nIu}=;Yhe4ZZTiD>ghjue-(kJY)vmrl^CRZ++j~oo5i8=G=e-v=? z{pYCxdi%K}u}!%Qf+l;IM=z5w2C5EM$NWojC=%=cS#h@OJt}ORPX@Mr3Yzp}ZCqF- zF0ojJtmQZ^y&e3|(wF=PWHUgub@5!=8hcsUI`dc*qI>PppOwv!jqc&>Jo=i+>L-(4 zZR?&hHb`Kgswn7Euh&Z%*Cs1enKHikEGy2CzJ&s2LMf&^f_&Dlp?rLf^c=c6U<}Tp z_|FRWaspfyPUxboY>kmESl~iE0LmZr?b{kIifKF_9POXr`JZQH5seFxjmk(`XEDQH z6_)a+G}F8qL$3;6H=(P&yZy=2gF&pQb%v zFFQ!`vV+ept;sf@HV%7Lx&BYgbpkdEmkL$sY(Xs5)XF@-&!$xKH7#C>@GdzouL6#c za%2WuIO;C_SxIf*jabMYFA*|HpEFuHvtY90z@_5AQi)tQn%wxOaBTN+bjDGNu45kt zN9NAw^cT9@bV<9!@G(yfR}%Mz=BDmWa1&rw=qi$p*3RU%%ijuPK=G(K@C$otFm$o0 zhK(j{2bh%uL*Kd6?=M8+THK%iC7H2FdsPMqdw=2NBBz9y7oV7*t5RZnY!-(TQgBg} zvGbM@=S8a{wmdf@CQ20OY-0cVl`V!0GAWaj5J&^2Wqnr|sitZFG7`}VRaWZBskm)s zPDO&&aL*2QHqQ{M*ZBVDPWpbX4q8p)Rl{4={f4&mHUK#2n-Eh{e1|ClqoM58Xgu&Z zh!grq^hPPj6rMPuO~*Vz>K9*fGqz}mf}`(-pQUkNP}s4MlPHm~U;u!h4X8OMsq@e@f!}dr{#!n`HDuT}L-F^R1l=th?`p>Cmg~)pUg)GR=$}VB z!XD-O+dHdv(-sts>HWgw<>i1fP2OK|0e1;wd6~rA!G$?NWlf#jYMF5<@sWv=X;sXU z#8u;wjS+fk2;)(w!~x~gr-p)r4n)tQxYN4XG<#o~dL~K+a$;F+=q75m!jot9u=)Pk zQ|7#tf#-nw@Vf@9hbv^hhQyIvIKa7$OJlB`sE zk(nu&N5W5i1<^fy9J0Lcsw~|~LjL0iDLE(i1|u2O50(Y)X})}-HOgVa=uZO^m|xuw zx4))md`(VMGpoooE1&G3*QEi&nHH3br5<<-+Q4?3lDlrLJ)-+RzhfY) z6?sng4cB{^ColP(#iLA6K)w9G*5*XhC1Yf&s_L}pACT#68Vvn%{-XKpU0oJ8SJ9zy zz@X6YJ#LSd;{5`?#%5S~{$w~|)~{&s7}+sdcv!fYr6J;D6J&^V!jywMJfAe4SbJho zIoPfGGF|yx5%p_h0}lpP7u{5uRG)z(Aa1%Vy_js0x11@a~&4_@SRyE`!5oVl$cUPfkk`8*LkUCq$s3bk&f)YOzp z0eRwr*?DG0254QPe2io_51m=zc0pJVaZ*}IfNoi^bbGiaAtRz_bFpPUAZNH{_~~0= zQA1lUa>%I4VIj7mzZF9kLBqoOmhnPr^TDI-ROHO(pg>k|6Vuo2rq(O%f1YVpz&-*5 zN&r7nb7b&0OC(d*R8H8-Njm>08CNem)igU5#1=Ub-M5II#G5aOU)iUJBjAw{Q7Ww# zcfJ7n_Z@;~=+95VFb4_yP)e=>;^8`3!xUe0%5NWam>L?qCad-gT!{}5F&075{2DmV&c>m>^HU8Q4F zWv+m>N@)k`WHkZ;M!fAO)V92aVwFYWrtF@^8eOM{_F4gHX<2TP(ygMbb~pirY+zNG z1n`c9`$b(Bo1JEsC!j0*E+IG(xZc`kdG2>Y8BZE?cZpJ>^FQ!lU_5~6T)soqLy6$D zVSRIkeOR4ed)a+BuA;E?A(QTm6EgftqgJ4CNLlO}Ac&D$I*Hvqit#D-{*oYi`_UJ~ z1clmH8>fr$|9tl$KM)~xH{p4!Wz&DuiVR-3^A$ptE*jetprdQzBlTNx+bjAWWDtE% zKjVk&)n5BPA53lJ9V^u2d_q$z#)T}VA6}l(6L&yHttaoV)veADC$!B$^S#dU@^iM7 zyZo~xOZM-XPnlnA+(llvVA`E7V8j{9(A?;5C8Z{Q(?sPTib$h57$fA;{W#*Apo|wv zmI*jOOyZ30vzINf35~iRr(69G1|~uX4L*;Wzlsv`%S0`0)s7dE>D2P>UM7uJf=?lv zjoBL0+hPIJRnSdV(?tN|@QIEnQDI-pxxM_Na?TM9reckngrkJ%agq~5Bxc2FEpQ95 zI7wbnxsmZx;53PN)vu(EF#0pR?9>#^tZelRwlUqo;R#`AgjTp=P;9G`Oe+14a3?RBs~1aFPgjeWF$t!@N{zmg)bMaJaIzba@Fua< zpb7@YVDmH!Vf68Icbb6*$C4||PA)z+9wuu*ZuGz19f97X%l?yq20oI#6!_d52oYQ* zO+okGz92L^o7356&$PvOMuov_<}|J|?ZN;;d0;Scb~CEfejio}yV)5f4*imnd7zb3htP)Advchtu? zF9N`DHJ^nA;1tCpSJ)ojVXyKAQ?KwZ9#|Wo?lz`Q4vWN>CZ2XyQ7e_+u{|IeIyLb= zOgd`SA>jF6s7nH-rG=IJh0XkvBEVii$Sli7U?qi550>}@ymr4;J6HLKMN>KGC^}g@C?}VZfHSP44$u^dE9&PmTgO03>iWMXW1XxQx3 zOpAs-SI-PoBRD`mUc=wo-dVw9IytG->-B99ZP%~re0?2Q^WBSPQd^2>c4-akAkEtBJJZTZ7` zyjw7@R8s&bGJYGAG!yZ$u(SUpCMck$QW+$tP+C~{8W|q_2uz~nu#^{7xZ7H=%9Yd7 z%6e*ZQ3wH&zp8F?wGY3oT8b_|KX8}5je7p?)dP-nS}8*REq{v0u*iv#Da}z$+H`l7z^*mfG*HYT=h+iq;zNn;xg+t^NHv`J$&wi^C!zt8hq>wVWdf88~+=FXja z_C06seLh$bpEkJO?>7Mqe(I0}`{Dw0sQ#02Zu+0A8oDLEl2X^l#=(!VUi`U{l9iXI zt&*&*lbn^hF0k|^C7-BN=Z( z$&Kq#UZy7a;cB^)l5XKpLycSmzA$BS*z6Fd4um!=noDptm z=x^{Ux#STbOO?6G9A146M7a?0xFtC1e{y(?|LIdp1LjX7-e6zuIKH@F0ivmo{r}A% zsX%%DPcN^|;VXjqYb=LIduwNFV>j>TvwZ*f?%tlJrVd*pL(ElRg}f94YKlRRiItYl z4(=9K`@PkOj`D8@5gC%4?f<}w1OmAP`u|QEk@DY3sUPAM5Hc#cn%h|5VPge0EB@~v$X?;#5=d-!@T;=u?8&K|6LOB4NkrV?j_43hwfd2tyPmVy9*+sqfaMnJIS9TlR{4g z2)f3e9sVVEl>Y_`;!h&N^a6-ocaF>v7j-E@}V-)&9B&*K<&Y<{ToH0az3@a%wBZ3fC+~Fzy6QRue_ub>DI8Xv;+91JD5gEi}P%hF& z>GR>gy0U2Vi8Lg#zzRK?3U~a!8wF%rUs>PKnqa@_|Eg1-QEITCw?C;>cVnkV=3)gm ztlfF@`&Yoo>Q>kMc7w^)%~CIJsBv7NvMOV}iW|}U7a4>9MMhxN%3_H!o2jy8z-Rgu z^EzlhHFpjV$4EpkxXp230Wo8gU9~;wL~xV`blY5b*cQV<)U%f*EB~8(0}l@oxSNyX+~-139mKH4Gro_Aam~8tL%2iq89T;KW{q^7qj+neM9v3gxJ0D z)%#*6K2#jB#m6Zl%aXSzIe=yZw=eF0!}MdgU}$LQE$l692ol1;crsI#oH17CT8JyZ zTkpCyr!n=1rDX6DCiszMHWP!7rZ|hGJ2E?wEJlak01G{qMT*5lNxBDU#!448qr1ku z60ui?pKqCkzID=*ajWt&ie`J@|NJdtg12p8NdEW7fi}p>5z+r%%y5B3%aoLMxMu|l z!N;|v>1@|2DM5fiYip}V$V!VHFw09}TAj_mPR&bP&2OeAG@v!K5#a@$+pG+9KAl`$y{f8mtf;@iqMW=hnZ6kd4Lqy= z>wH+7#^!xJ;aZ;jt9)C#&)!#aMu6Cht-t(GBUP`n-_%_YA$j1ed2+vc7xY);*(en8HgwWKvSJaMu zmL1QVgT$8u*Lsb;dmTJg2KxJuso-xrs9*5lnK+|^yQ!?07W9kko`u@?Yny} ziO4U9=x#D7Kin8%NOj3!C3JfAQp+VK9ZMEXYfq1>NJ}cIGQriKFH%;_G{tbd^3_ikAbsahTSeaKg_QT&d;sSHzqV-Bu$xn27|bpQxY63Ce@fbAbuuzawtnt$#Ayz;HRd=T6o$U48u@)6+@u0O=wTn-Coxfd78$>aw44h51B4GCTdl*ie^ij0GT5 zY1aw$cXxJHsAT|D=vyL(GrT}f$Anv0~Q z<((_KDm@#WkE^Y%y*&d!q=TzYL#h2S36Oy#kpVr30wd?>_*i&2IKT|I;yo-3a(^^3 z^6bpu2TM{)OHrc?;5fK9wzRm2iHl2uhBw&Dg%`hzY7dxp4`))#5-SDt%xmmc)imqr zYIFy5x1&K*P?Si}?8L`29uDMrrbkJGWR>xxd_u)ATIMSF9ig;+$2g%_ex5j z9yIy@S&4M@MRu)B?Wt>dithpbVrtgbU-+C#0INkB8Xoy?Pv0dX0Dm&k+}u5BX+ZD- zFggO9(PUGGDDJj-wgR;cfW3Xelk@YQfIm+5xqsKVNsaY;3QJ+s``({(;F-#%(eUw0RfYjbU9l5@1?=nb z6d!#mFQ@YIY8VuwGF4V4IgFYr!OF|ZLK>Z#nKtYSTpU^yAY-EwB1;ik6X1n~jtJFH zhxomRbq#oQ!N*L9h}CL4cZoB&V7&P8$7ovb~RiO(c&z zMb;t_TpXR&U&0E>NmH^U{x*eo&&qNqUE|~F>A${CB45IBLA=RHgZW1JF?nLABD0bd z_^Rveoi2h>G_tmaswlTIhWnXF4)c&b*%pz_N~EW_*wq+AMiZRa>k?$rDWP8^>E)HQ zLUZ@Mx#k&w%Y`5SjDNrZ4p4TWm?8(Yx%Xd_JIKC+4}^%4mGC<5vh(wIDk#sAn(`gd zRGaV-WYFS|OGSwfk@qK^<#j_YnvubBg#ca$#V@cgQ$acs5+*8*wB+i(QWafMU%L7A z>Srcakt=m2{v7^UHSy4NP~wKHz;LTBvxRL&V4Ma#MhElr4Jj97@$oJ9CXiExRmH|J z)YlQX0Z+Xo5@E|gi9i@Uj88aNg!G+IneM$StemEkff~it7Pk9xF5jZ0r4BTd%Ka00 zHwJSDU=(F!FjmCrb7K+cWX5c;1OxAmbS*U#XlX68vMgFA3eZ5NDx3qYE>pU2N}b2+ zOfg8Iv{lQ;B%naRV2in?1V#h-?aSl-^C%2W)bf7g_#*9i8O~^xE+a?+j6=`vXr(rD zX7AHyncrX(YWuBjzq7z$l!AN424ie-W$$9AN_e9gs0k^iW@d^TWhSQ5Ch>8JIKBx9 zu-}+v$#DPV$wIc3!A#54NksT$hA%Z%l}AhS$~)7f$#CL#eo6N1 z#y{B}4MVM}P%&lI)!Ez0DpP98EXE`x!br?YD1U_M>GdpZoNVu}ZcN_*HV0tHE^C<+ z7B&RP2(7P!3PCLZndTtg(aE7?24Ir1rm@ig&U1F3vukt5HvCW{y86joZwiImr2Af; zo{<62&~U}o&BF*3q{GEVkcO5~$fT02>{wz226y-pBxVTc;$kyFaXK8|R>UM3Fx^a} z@dUuax%Plh@A)J(CNAig^E=nd55nD3Ru3n<_Xk)&mexytONWOlN9*$_p^E*8A!gOc61Pw-A(lal(bpj8h{Q1!wbr2>_jdDBc# z^Doc*U4=s?x^Le={4pr~>*Cotn2GSvl&z58prN4DZzm_|-;j_{tQg6Y6wavp{G=H% zR*50hEj8t>#l!}g@@ej%u`@HPkdPB*&xlxS&{CPm$@%%H6!$~2>|hA62;E#<#163O z;z)#j5(~-fX*071oE#m~!sTJHcH*0DR}G&C3BwO8W%1{kL8ge+OLqQ@kw53>0rNK! zBFwSh8(oiJZAnfl8B*#op60VH39C&oVSk0lBs_{?2&w$X?%Geu-_I~s%%Z1;e)26Q#wvg#6y2b36K)JSF&|=&phph&I6tP3{P>; zZfBdKpdhPj`giY_nK|q{nj@$~M$4n}{h}pD`W`VN>Dkqm#NthzaBg12VTyViD))3# z>kN3q(qcW^4mL}{hCqqP=aCC>D}^A_ate&0+I!l&V_xF@+FV`^qtKxBc@8OIj2`)J zF75f*bB`+cFCH_n$}1|!S%H9rs9=>(#_9Ni*mrL62P~zHqvOkNt+TlJ&;*j+949w4 z1AFlh*giOI1`Kw#$UMU(5b zgLFJ8uC`YMc}jq88RI}Y=8KS!P|R%@&Z35fP=HgC8zl!t&-+GwMA}N4u?`jvaYtL5 zzJb9cN`<@$t3XCGULP0NXL17lgqB#tFflJzS6mpB+u#5MM$_nkx9M-g!<3#nfG4e8 zTWJd-5UtyH%_0szV`Jrtx5yMg0)AtMhd76SjyYb`H1P)k9(?*zNyNeU9s7QKyaLkm zjob7eV}E2Tlfs1yz*`uAm>mhl^Rn{N@FWqTcDl7@f$Et0!OnwgPL9tHQ~*x=R7Otp z(BF-OwW;D2Bwl|2qwW%HicW}8v3OilYkvvymJpxHZEz0mCr-W`ofcpNGcbUtn!>56 ztE<3b3JiJ_dMB60tt~HVOg=FGj?c0NiKzFWg-_%;v^|GbfX{_UChp?tIRa%W&zdG? zBfHY#pc;?&6GTS`t&wbvVYY4KpPtAU=n>urO>fQuN$-H#FEY;dpsH_!*{D*_Z2eRh z+NjEC8)!-<$o{<96Q!iYoQ3XTq%%$UwZGrQ^+#`z$<;-Vv;(RN+Bd2TRDdc6faVwV zGhtY=nG|)W5^GLA4bo@id>g$Rh}NIqXJrTCsAqom3qd>+q zIZc?WJruVUcefj`?fE8Es{(Q4iUr4tbWL*%)D71%&c;B zbk!$No<%^92DWEOWn~)}s!~2+e(vZC@kHlO{w(uWh!^7(xrU#x+3)QYLTWwUixO{Yx)u|y`tgHJ9{Qniq);dz zkz2Gd2PsGvyh#yX(lI~tFfT8!pE%q`M4lGfFRTCXPzyqcdJiQ(A;*etnlBMvKFwV+ zI4p|ln|Y`D{K7)4lc7*=1KgF0FxvQCiAr)X?B-_g;F^eKdzYUc-^)sU+vWNXnJ=CY zd6}6;HENfaBt@j5q2j95QBklffUE&}l^Ch?D6tZ5wysbs-US^!q;w7)P**W~Loybx z2fe1vvO%oqVVTaFDE@dhY~XRJ*%0i$DDsRf|nk*M&xc{za2DO^smihwEc{6Sx^eC}`L7z;+j}c|w%sikg=ft4wsTI|ktzRmEjV z7VkF5!y#|+(W^4her0n5=p!_uD7cB@qQwgsfpar;&~il;-)9CUbOpJ? zJ`oViUoItaqmi1*ns9?TbRe`wK%~Hi77lb{f2rc9G+xwP?}aQRB+MTct^N8H##Thg zpD121R@nauuRl6EJ_hKF#l~8}fEoHr+$A;sm69H7G{a})2=#xPwulyCDU7VmscKpo5|okyM$vX6^Z|F!-DtVufAWyo04WOhheIalAP z+l~ro)FJlwSK!R&tsC4S>gVZZepUx$9+HP}VEuTP2QPgd)=?tl>1~qUunUu;^Iz6y zn!agvYWJH#!N9=Ve{qEMC}swAcdtH^9&8rejVr0^j{F?k24vY5)qcBB_x&kf8JdUo zYplQ6^rLn9C3bM|35fxVYBNj>U71QlUq@pqyAqCA!9yW$e06DkaMLU-wn~AG?OI96 zX=di@E|X@faOL>)hJb*y+A|s?><}3IAm^A%BP@I=1KSC(j+|SZ`MmB|_Y<#P?ojT* zqoYAR%;}4u?DbT4;0KHWX3d{i%M(VW+^I2(mzv$n0Deox@3k@QbycWt4@PMQgt<5Jfus?{ot=+j`{f}_!wDog7maB zuiKybMvL|+?2eabMfu=N?(3}~wkShif&RyP*w|Trz2fortD!MvR+aI_-rj*%NEqUR z%|QY{&aL!(E^ES9u734y1qxbG(c(`D9v`q~#8400 z5W7Tfne*E^dVt4zmU?h(PZ&jSLpW&0$!6#64U`yZK&W8_!;3 zLKnEJHi`Mk0Fykc`rXuQ_B5t+uwtN+j!x5@v7a#aH~+@NPi~{){CvpRArsEcu8-*3 zmY$Xb4%e3%!-R_F@^90Ni>DVGFNCb&Pf2Imd5c|-#EsajpH)2xgD(n*`!6TdyKpeO zoABP>4|A;;b6NA}j8RF1=8x~f#KpaB&)~5zox;;va{GzXdASs3r@q!V_;~vQ9I9gF z^37Zs{!V7%yEGyaEW*R%<1pyyRjFx!;l2mu61lgFp<|x;F)%a+^ihj}8kXqsQkcHB zs;JiK!syr6EwH>PE@E|`2&r{y_OT=sfU5Pc4UFV$6V!be1___7pgd0!>`0WKe^vuf zPnBp^LmdQ6pIV@S<`Tq$3q2seHeyKhz>`_sPbMRHSzLJLhRQ6O;YQT67h54nK4F)E1d@4qABG!S{OlxOxws#Ojh49cAhu1}0!pJ;AGDr!O`(}d? z)nstSJEQdiyIL5N=+idVm;G9z@&LnBr_1k=WYP|95c>6EH2-S>raA6#yPNy%v7?*Y zCn87`zM;TCaMI-Qev|7dmB;XGe`n*qt7yy_{Kn~CNwVE!Q_Adeh-HI~>I9HEPBz>S zJ`GYD^lh|aoO03wz?N63{-OJvn81tJEc7C#Mb#R3{;YVH9$iss9s39L>>Jh< z)z(jZ#`K+Ehqte>pAKNWT5wmr{%Gj^b{9j&-rm{S)#V2SCjpYwvqBfJt-vUW>Sep} z0sjXUDz%tez~;&Ujx{#JkbS?MHUSF9lXs=!GeTUdHCy#g&YvDbpD zN0qpa3t7)>uhoERR>97|RBzwA)6d%t4bZDVTB5eifK8g$#>;ui&#GBLCiI7uKDNaf zSp^{EiL{_d|HlhRL3$;g_fwuN1M3M1t>W&&fdC{VZ9Y?vu z@P|yePlQ+Mh-DvhZy~{?n-B@XTKkb#GE|3Ei<65>ynAc#Mn!mZd}p4_npmdABVc7N z&!u=$)tav2MZ;z#HC639*B~HhK(Yk}MomZet+N8>987_jNDehzuqVK!gfDH0rA|z~ zgr*AYua{u5Qss~ojsV7Bpabv4#O8aTk5746DMKJxjy8H>Yv=dKfP_^BCoy(~csUeG zD=a^y6^V9Ho#%4;+qI!31sXPZKEE@K#O#(@*!*9|rw6!O(Eqf)V&GY^byruLX8{F` zgl88w*DwDz8N7PVVudlv_Z-+l| zPEky9Z?o(4JkqKVkX+nv#cH2np`QQ31k?7uhfERQDp>F9|3%9mK$lgX#gHE&gIxpu zn(CL8m^z9>#C)u5vKiKbgQM%W0EWQ|m>*PN?k*+%W@^m`3F;@NkiT*`Q3zQ0xfAnA zQ=y7=fUU1!@$ZGp0=SHrkYg%bV~XK&mfcxeoYsFxH>ik-Q-~d#Z=1SYWB4dFpsvPA z6Zqqz<5LTj=d!zBAx39*tt<~>Qx@7PjX7yECTew;N@!KcfxcEwKPyZ88HNV%^o zL`ATdMpgZIJq>1g@!4*Pl8Qd01@cw0VP=NiKaRz+N!`$JD3y9@;a&LL&<(xCm!Kw( zK}0HnzHouQHhXH)H(R8!>eaRlIJA#K_d+=RM$F8c-I$4Aj(D$n^Ey-#FfXO{H@7-i z0&m`zUli){tLSn99@qLHg=ilA5$xk^W-UwYo3q#_Wo3#0Gvx$2Dy zZ4{Yl8Ru>8kB=W(T3&({%EU(caFV7$wf6RVX=$5e%dn!60_^O*m&_dq*z`i^U4C6$ z-@ZXdj2Lc!HnVFHu#Mq}bNw``REotSVp*d7o}ZuXPs@_(UN_o%dpEa)+uN@M|7Zgr zB48)Q1E0gdM&;xX?=c(!S>R##@Yrg#DDV-zhTyREVL?K|G$3#W6e*WpCfq!2)YLR> zZEcT_k4Xnf&}Zj8LR~Mpf5V2vuVHrP=Tn|sMvjl^#@5yZFw@lSPYV<+nVFfZ{yyIe zO#wQuaxcL2%+=F;^OdC;pEhX-JwDt=M9K!yn6uMBK}Tr(2m*xP z2w2`JiQ5fyEyw_Dg61;U#7*JZwYo+6Xr4(-;(U0x_j|0jjSZzB`EL_eDXEdC?z`EE z=^rx_z+&(Jd?yLCO?qahnQT5c?VzWK4w%wa+cx6nX=oT=5a2p2ng6)O91c#5jpAX=!Ck%=itUvt>@TzKCb5B8A{wzXofVINGDK4CBd_qUx%f;B_ zWDS7LIm!9`@!ar{^09y0+1|cn!@gLmM51lL_;$}O2(^lZgVX2Zo}GDdg$ie2XxP)) ztE8x?tRPo02(*7yuDVc1|0f)zN3Hh?LI+DKX9Hqm<%`i$3o2)gMCcbhlgUhBy|(Jv zvYB>UGV~nlZX$Rp7bW@D)wPVWO=L@;?B;Dg@3LSh&CUQS+W;0|8{(q z`=xUI^yILf<}~Ylv)?ftS?k5e&hGkLT53*|Z#d8PJFTmaQt?}P3{frTr=A-*eJiV< zpbIh{IR%BzOyMpcH#ZCdK>x(Xt&3(n^XI{sFh!~Pq-UX18^MLGqhrv`on$H(7sZfe zo4`R&T5VEN6501Dh2z{0u!|<0vP&sc)THq6aNi&q)&GfgY9WG04NdK+C~06ruRGvn zZDb_(`}c?J?A4CHf4?-m4j*EwL}>jUQ14`_NJ?N~xb+7x2)|cUeK$+j-D|7skr5tT zhJOD14)odQ=H`y71nA`$dK;l0!y_fTQ;buI3DVlFO-$ybe-B&kw{4X*Xo>g%{Ahr0 zty1*kV70Tft&N3@?D%}G%|*E}4?E_6Z_qe!gIe0!q?uDQoeB#I=olCPyay2pNncM7 zSy%{xl$2CloP6KM4vCp?YDvk$cJkH5SK{VE>)8MY+Xo(J$_p~^-Cv^>70$hHWHda^ zQ|C&})C9YVtm;7@CK6>Nv2mL~9vhop;7OX7sH1}&AjRCg z#*v=1JOr|G-<_WRht*1>nH}$6x}^RWPa}O$g$aKBC%^S_Hqfz&%sI0sn1*X-qoSf# z`8wD>z0*y!l_X}QLL5Y6U1bQhpF5`&9&a&j^uzi^JP=a{#c zP4^uxH`kb!nGW08oP~)ADC*--Z|mynG&Hp0W?68szYN;|f;9#K0g%Y4yREI?zi&9o zfrR_OmJNSw#ZAq!u;T6h`bkNx{=akE>;wp6GicQvmD*iQwAdPwxyZlvo|vAVe#EM+ z;8r+v%U=Dz!T0BTdR@Oo*QuwQG%rXh`u>%fdB)qfO~3cQ$NFjVs%jm;QLq?kyzqYi z-ZuO$Q{etT@%wp4wL|*9Q&fS`KmN}XHWoPv`WM{AyG_^7uCr@x&dN$kz?=!_7(6^a zdU<*A2?3hcsSmav1YWP@TR#|V|G3Zo6&?b%Emv1phXVGnRYcE1g6N!klwJx*dIbTp zD-jXN$Go&XE-o%mf7GGKe*<1^ZDWLV{uDt%2EiS1${7?0P3dX}=Z@DQ<#9aD?Xm34 ze}4H53JMAWm5-jTE_&hDqU$iA#BSh6%HrR=PoZ<#1o)7=-ums;%OxM}txQ4P9uZOQZu=kDz(+S)$MtMZ(4 za<#D%w~m{z{$5z%Fw_M!=rt~m&pGfECk0q?3398yw^G{20`eaNtku1}?|nz>#S@Vg z)E1|FAO8KHXQr86M?j6h-~vt3_enw)mWELpYS)9YF&bb8beE-9825zW6Mn&;VZayDDIw)I{obDCHqoL*)>6|s`x@s~ zSFk-dm~LCE#;CUTXj8+uQB!<1X*B8aI`kyu5g% z4&zvC>CVR_n@|75@$te!b8`d(j$aa8Inl%Z^Q30@t?t*eR*#p3o14MG!S(g^lSza= zoG4XoVZ6=jW)1 zz*>AX?Aq}4>u-l+&cRM#MSz8g0NfzdqND~XO2(l0XdmzIrDFcurX)DJ>g-ZRfXQ&Wtc z9!#H7a?2Ng$j?$`O?CY^zR$1Q%x5*R%)?j0rA|uORF|x{*Vh|_DzPxTjn3WEl+qkmLZR(@RnNE?({#?B6|X(w!9!Ht|qTB^b;I@~jr?_mEB z{bf#GU)oyBQ%OzD4FF5@xtRh*n)c2ifEQ}S$(;tK0YQF#DO^+26e=o9iD^yEw5er2X-0x7J^^3hS1jX^LL z{YYl!@g$I&j;H|hauzg~y1JtdF1LZUwy}oB;QBdAWvk-+ysJkmPT%ZG6)PvF0!1>p zDAjvOSLLsrDG3RnP5+8e?i%wWV;aiUahj>V4yDDVqj?<0rlq9B4#3*PL;cCh&6O6| z)eu!xwYAZqWVV$tN*NuMS~++)%!KiKd6p!CR;rA{zRP=kAn>8gxDI|^@xJV_*DXz% zSIxs6`wJ}@>5Z96=_7{UyWg;tFMCEGwW<$N?A?gmDXZb8|qiQiW9fJ%<%ZdNWCF^&H>vJQdmOsVsw#mGvpm z-Tm}wKb&v!oZrdMD6gy!n&?pM1!V)hP~DWQu6 z;Z{0K$p9&@+$Jq)dvlAp)th0U=;I?P7t2INrKq8P%`#T%hRXeTn)YYw;|jHwYjw?Q z9r7A+X956n@;Y7~-8~`>^6iQM;N)oEPG4Ua@pkMiYC!2WS!<~q$if?S_K>6uzgo)VO8Eqb_p%h=B@%7=CLCP5XliOt&F*2~it6i!W?AMyLLohX?**DD4>$MN z$ove_aOvXM^wgB5rmX&&YG~;lA{-8n3)nmQAT2XQF9kq;dFi^trmf6b)5XE& zAemv_lbe@+YQ^|DQC+~Jz>i>8te#C7dSkBRufjN$w6`Pe9C93wi-Y5>&*-MZhaG#=mDFrU%yi6-@jh1IaeWfmMulS>oSVH z0IH$1nHXh&4Pm0XxRy(Y5y_v)8Px&=k=8oKRLTfI23$@~Nmti!M3r4Pm6aMBv((T~ zKQ4BDXSy1dhxN3l=NBy=W=Lcq=<)dCBs(W3kz*LZ@V9z-2nJo-c`PZ49iHOq7^=%B z7tf#2&{T4B^CVP+M@C9XAfNJZaTQ+)zrB`y{~BWaxsw+Qpx&h;IRi~>X$3Et7@L^; z5vXnR(cnNUi_R=8ISiuu(@T=6X(lwD92M@;`Qdm%U?Vb%YcQv|`L=!7hO>p-g5$aZ zO3U5XikqH(6hNCHi%sqR=x+C>3MkIw4Ovrf)K7BHR6Yh-kOCLtazw*ARo9a%V7Zy1)p(RCR|r zm@#BzMe@E(J$X5)k16;}yab$xNJ&733g{ld!bY*;iAf$I#K)D585tQB7b~9yM<$E|_vacDD_@ z+Rib6$Q6(#S9kOGaA?vom0qBBJ%u+?P*fZfcSUjmccCQC1m7n7OEYM<&IT^|s7NW7h!RD;=)`#dMvwy5<9nb?s7PjuZ;Sbtd~8jBjWL95Gd@XQ z=V};7;m@DKLZqbbFX#x7y}W%{ncbS^-ShE()Cxqr-Dl@_&}+lwN3y9af1B+gVPQ-H zl`e-H#A|Xg91H_JVsh8hU+D6(GVUcFF{K@J)p5cc+@x=$@Oc{xlX7_jP#_hc0ijqj zr8z}3LO@KU*sE^X9^#Jj)Tyj(cUSjUO4Qo4f0HLqUbg$;FR=&u0(R~b9_`e<#H->;z%>zvy2 zVv36Ao2S3R1$Hk&WrzU8H=N?|+h*jblpd)I+pu~jSY^p_>~w0#2m$7IFHd;5Xqs>) z6GgmFZqcznlULP4M@+G9u+>^aFjCE9{BfZVyuhYt@kI* zIXG7xl*08)(BD(w*uAy->gw1j8B5B)B@CyN%0ltP115$sNJ)9v?zwrP`}9R3BWYDn zU-ncxto_Z%0oxl!JTA@9=cx8E5Ly^$h%WJ)UVyW)FbX1wfC!&rk6KBa5Sejz+$H9W z7!rpKr6A55-#0prXSe8jPdto5QL#Q9PR?p-XD5Z1 zT?t4;7=K!{>b?T&L_A~(kf$0!fa)TGf93l9{K?}|Jv^vEy*rxv^8C^S3%8O(ejxG$ z(G4~g@@t6e*D{Yvl+yJ`2_i3i5KW@%+tZisZhr%RpqJH)gd17MN}tM2za89Y4O3{W zLfcNm!GUNzq}*Oywr|lMbqrUcXP~2?&^!nNPy>|w=_XfjB-(h`OdE5!RNT3DK5mHv zmmBUsCZ?^)3Hx1k(C78?iEZUI?gSp!ql4zbU0>3Vp6<@Dlxvnp=$J4qogJJ~y2Y?d zptARVVbNn0A(ohs2e?kU^~dcdz-&*0hJSc}9ULqHwiN}nU1V0)Um+lpV&(_PTf!p7Frb7cH*baLX#Wopz=c6K%}5QGOUkB|JFa8T;sbEj{QvZP8tyEFj$4?u59 zK)}xg%QYzV4lzK)i4q41iDQ236P)W4d_OEyP^e#-ehSCJx+=F7NJvO@h9<{SSD=fE z3zE^xN3whZ)wh>xF4Bn8#Ey8c^^*piguWbtwUKXVk+(YA$u&}b zt*=)XbBQGbz{cjtD!9}&P!f8Mg#7g7in3Y?(Y%RumKvLoJlwPqGss>dnOASJUb8wA>jJ zbeSsTU8E26gT_O;O+7s`xpE4!Ei1A>rVhTHf4&QBo_xGCd`S1lOPeIVhWnLJ&*YB` zmhurQjgry>MiNqzV-~!Iytpy9W}FJ9wm#V_9TgQb`Y7g3JmCY$!_}b+&Fq4EM_IY$ zluILj=#{~Nvhn(cm~hY?`%C74%N$b8ZleJFgRAGxj%sXk3OH0$B;6&fk%0kgBU0tv zQ7Ct@LZ=IVxnEWt^sb~9u+rhkV-Ta+jTL@U#AzlEg%wMlSM^d+8Gm}Blna%^L_?DS zdaAA69p7wOKk4#HShQKAA@qmZP{7_ns}?`FBuSMDuY56LrAwx5f%$6IQ^Z+85vi?V z0F=p$4Q@iKVAYV#l58?`M!h$fsJ1q@2Mj?^Vdnkpnn0B!?&>Oq-iDo#x!ub*>RQ@b zhkhfGjn3r?bHc;MC;2KdL!%e$3lA}_#lzEPtF`ZMfnCQH0`aTFJY7TUmyA?v)4+*% zi9%mZMdUD6fVl}!$VK4tRCctl zOVA1)mYSBTPvFJh77V23&I**nZ9I9>pL<}1@>9_WyH3sSZuv6`3PkdU>4`E^@E9FX zJTz^h!CKJ=z;;tdbMqC~1YPyh!5YEwYS)lxo3{?^KplH`+-=+q&|1#vsjCy@X%O-C zG6^7(3pN}b8{2_*unKU@A4fDF9rW`prv!T(W0NHqd+N%|6WrzP&SKg~(N>X>TLMt5 zh7%weJUl!Z*^~?8#qo>He;y>18U|`Pg~t8yE{Yf(7_{8e83=II%Y;+GV-l`j;Wt4>#jGf6c zlovWR$F zj+vU72>TEePL4>D*L~XG=lsBC#>>kiTqBzK{@{hW=8|vgDezfMt$eLR<;$HQ3s=Hb z-ms*SGV1u(BEn-W3pMuGVQ;w~^d_!teuKY+quqWpGSl%1fJ!UiUhz?P;5un_+-P8e^sJP60vY9=;-N-y8us;CF;e4P$xcY zrlQ)22&yVhAG~@d7I_8nL)a8FHWP#0X#k(K*!}8nZKY+W*ZGPti>;f39N8+sPMFPz zFYj}Gh^*_~NfBlNVpQ;TP8b*O{wih#QyPbbIY(!k(0*ATY)L*>Y&_fH?;des_2&?; z5sogocuv7XXZ>3Jnrd5qpLi;F4ljsI$<<=mYZotymRuHH8#RzT?s$!{5M_PQ&g zQ6v;N_rk^titQNh@hbp!Q;4{c|`8YdF*#ZlPjb2{}1wYGMp>asxr4mTXGLd`)5F*3m;$S9SIN zLTi_q{SME&EPv|X-{^wV%wQoDKyXAW3KB6%LS39JLbf=D3~Gk7J1;l)##n*B`*!Xz4J3mkX@5!>l_07gkd0|uzuc%2EgT%;v&M5r z2kUwq5tc1@$umm;5j2Brx(7%d3m8gB_brHUe#PU6-E00s1n~?6aSxFXPGgtcLd&c0euFBoc_L6ymlu50s8OX$*F%s2IMd&zJ7iz zB9H}JmzTBQzw15G42VLzzE1+B`GHBbl8=ADYa<^38YlSivN2o?0z*)LY-EHuPJtdC8^_0bfbiF9JTTJtaCIdi!P?lE3C8vmY$!b! zQG0O;etw3kBktRb(K7HUWnOi=hTR1_C4zzxa(!;E@H4Bw@r!0+tNy%_fFw|AipDFF zudozAIUt&GefFmtz2^QNJ2eFzZDTjCs_G2Hk1p60U&!=VfmTqG=%K2j4CaZMj32bW z?S%fP_cb-$^$ledsOIbpneXmUQo8u~`vYc76{d{f@AtT(e(L*&mIoH%9~Wf#my51Y z<#inQ@ZD#WEs>|T{{E7-f9K~;!G_y)#$KGb9|4f;;-XMSkB^RGqT)WZMB+r+A*OEU z9i-zG`uuWc3|x$JzWDRU6^J5cW)gl_%3I*2&gmN((x830SMPe`J5!25dM?sbIX<~N z`K<+zOjb_L_3I@LE-=kyZv9=)@PW;|co-OXU7ySjB8*Q=oSK+iH&@=nCc`{)wxHl9 z5@^SUf@Hx?mi3b3Y_6>x=I(6o>TER?018KEnGBm&c3xhW*PEgpg}@-({psncnz&z= zQV_v^O#>G0aU8LAl+GM3J?sP!P}>Baz(*PiGf8G)^X%^D+GjmtHlo%^+KfRLj^4c^ z9sQ8jKYxqjhS|xLJ3P$LD?G41Dz{Y}+J5$Hv!k_G+(Kg4I@~jJb57B^P+Kc4+??|K zJ9!AHtaGa7#-`tHW=i~B{B_I^bXRmUN*BYF`|K;65#vyqc3^wJc$i6U#27!?J8!Tr zZ+y^CB%sHyPpiZv5;^c-&acM}f5tzK{^*v8IW!xy<{yeHX`;tioW+2dae8{riC^?# z2Zwk~Vgrr7G-ZrR5-9C2N{pYgb_XsFf!0S|5yaG}%r;-2-S~qRe)F7OUG0x<7at(j z%$rJK;3C11du)!%O{-L1UMuC-MHH9Nnz~QAy(jEiU%S20^*UTmF#d41YA_2MFXO~Z z-)E|t-wFO{Kf44n_wG1Z@+_;WYdxfxt|UmH6Lu_hDv zzGAb;U!sPCJ`9u;s$5oHHa7Bq89pf-oPtkdHLAc3^7I6sws@)d=vBH6T@vz%@O z7Z)$Dh(5K$rYz-#5Fgv7_0OZ-9dquLEWu;REm&CTl9K(96jR5#djXMzU&rb-e8t5} zA1-*y@d}7`7#Ud1Ce_tBz_{X0MJX2-7fXeBmRHW4{L#zCy|$iXv6Ux(GFQsBD?fBq zR7}kI(UH_C5E3if%hzUS(=&{RA!#N?3nLfzw2DTQL=Gpe_Jn6R1h=(8`Gj&Q%&&2% zFX>-)-Aa%;{TXU!(lD@#`WNb>aKQCVPgBEu7lk)Fmx7Lm=Y{MZ1r3#QX^EdYc9y_lwG#=fD%Em{{qqQ1ZF!cc8(Z6kdGK?>k`&B|I#5K^s9+(4Vm7+aH%Df(3@ zeQnKe4}*+M8z5LMt&m?S-ccVx4f$`(8gZ-up`DeKg&K{OUbz+YJY32JV&c!{#)K-r z`8NG7hKC2zOE8DUI0z_}YFW>4@`8hD^irvdxV3IRNJF(0Y}JwnK9vBvMVE$w9|xDt z;v1cacqXDpJX4{BdyHj_5mIc-EP-qUm!N)jrgc??(-sO(tpefFuK#b@!QI`|7WhuU zQoL^RZT@?NM?83-05jCzFR#Cd24K5s?=Y^RZa+TvQF%}~G22j-0=ePgYRDKoWBGXb z7$1k&RN>%?mERSaH?r#R8gX*76qf!>$h7nF;-}#z(ZuOQz_=ueM+|rk4s(0p^s87( zL9Xvrj}auzUH4K#J7T7jQO%-iiA(`EZ;6hlCmA?B4UNAq=%Sz9J@RsLBEqF(s`{az zB&Z6xVdgI*y91p~)vxXrc*xk91S6ubn2}IX1NTn?*#w!{Y6h5lyNI(5t}P8e;`E`u z2KO32h8V=Gz1)zJ)EyAOODpa0EfVq$_2;41iW9N{(MxxV2BAs8PI z|G2TdMQbD=s<(Ce%NKvZ5RibtI0o{5J-ModAZ0J67i6(QX63@*j*s)yGZ<*DYwSSj zrC?qolu>DLak<)ytHk7_xy1R1utZ7-Y~+=JCJ<;U^2+9TIQ3KmsHvKB@c-a(zi3Yx zcZ89F@H%3E=Y8=7-tWbQZ6AV^_3fZTg8qX8I(yl~zAwlWdrn>d5Qm!U+XRJ#uAc{) z6$mtd-Zej{4RgvMSvnS8ac4*!X!tlp{?^N#yl^|-SQAJg|IS}pcF5gBVJ);~C^>p` zaPSjeY~!G!qa!4e*uQcPnx|1dG3)O^TX`qh+2N1j_-sbvg$CIM<5A&s@8~##NI~>l zH@0MOe|mb@(EFd&0IcG+Uo@6AM%V4+>=r%3_sR~9(ZXN!k`jG@%2gx26cCTh$BH|Dj%xlRn8m1ZvS)vVQKV|cugeM) zOY-&Wdp{|uMoEdu&i!q?;gBtpl(wkIF5~*$M>pO+VM?BRN}Is<$*W_)-RHkddz}?RnG8foz@e`T5zl zJA@2B@4+v$ekv+LznI3R=t%yr6v=ew2g^4ZsPXY6O3EtRy${D5>e`b3Zf;^9lC7rvqOzt$t9@(XnRDP3eq6DX3qx#zzfhZEH*U7YPMrP*1bIu_G)kY#O8K z12NcfQe69>r90qSluAfg4Ps5@%=Gl=A5*fE%@7jQMY(yI^c(1hP?3_jeu^J38FcmZV5zssv&aYu-8_8Y zZua*TanRVG$CVftp!dYgiah^&AK&E>PYU;%4YEsFykJ;A4}7fkb8`!Q>ofe^rdxQ| z(}Uq+4v%rXn~S&zRA!W`JpY1N1qCdu)G+mLy-DzlkEvyB*T@egae+A=9$gvt1#>W4 zqni86tpc2InPNM6O6d2uw|_L zadSj|3eIr)$B2FJ8Pf}9MS8qo8>J#u%> zc>1|UWr?6wXmRitW}NvmN+@G&7SydoK!j2Za9k*k^7qg(%0pvOM`F+cIvVdSFE#bO z5a%e%K(1=N@F#fdS%r?h(^GpjH3mj%)RdEHy54_aED2?1Wzmv7E7M%cf_pj6GbOk@ z*Ykqt_70swJ1l~ljtwy}YQPg?ug|m+3b(jw%KjKTHI<+9kJw1D-aJh_P=!rH!e=+k z@`xKCe%_#`6@E;>#P8&q&)YECD-|jhNAuElS~t+w4=$0LAFv4!|Mr2r{byJ8%n{5z z#x4+@V~xi~nZOoIVnV_enKVTzc4|wvuQ$3k&2OqhpcsVz0pfaUO8dY1U+zybPVC)z!#)%-_tOWp=i<-^kIh zQa4=C;dUm3lSp{2IrY*i`9zFjI+KXGDIOwB2do=+UfHqcj(4X0qVg#zpJ!(|eXQ2y z&A{^p;XtZU)}6b2cN7fW0zn#EQ^K}n+AEFq!y*Ll{A z7rmi3sa|er?9-wYN0j$TMa~eH*?=zhVy)IT<4|G{qRO&|PN&8DHIip+h;j06bjs_9 znNhy&-K)nr?Hv)ciazA$2wTg8y6iS3*&ZLry9YT@@g;)!ir59U4 zf2$feGB-C5n;K=>BH5Qk$fJx;i06=C^h`;mkHA!M_GyOJ)&9&Q1jem@k!-t;XCt*_ z=WTTD?wSuMV#$p0BX_bUTpD|W(`n5OKZ!~bF7ckSePM_wQv~|t{5;_4bnrB%G5-y~ zFE=Gcx2VpmWUvoRV8gm_VEIqK!9$~j*@;t)7Pv2Y?r23v>=YBX03Bz2$BO{1M)p#tb1q5 zH8DKe(Gs0^oDBruYHCEsgR>|(Twz_^cOahaf3I84!or3}Yi!)G+R@w>;(OODH1A1X z!ndy6-ZthN7YtJ#CD6L@19$9&c+K7k4e!DUDhY!(`tOwTZ}d2`Y#ZGb72pPeCoDzu zUzeWjkagICoIpD7hc&3Pq-J9?7kLruF!P-TP)^n>yk}vwhTR{cQNAT|AJ@kCOmUC# z6x9*gR8*=<jH#wmIOEtjy2PuB{yagkVWc5*z}IyirjMZFEQ2iS<*HQ&;nQ ztT?mvw-^^g32Eg#w3-n~4u)!N@krRxW=n4x7PDJdz6Q;UV8)ts+;9Axeyc1Cdmfz(!3~^tn{9a|=Ra8{OvIwFC14<;^&5Z%~{ZmIwI=DDEKrkwb zRQsJ;HZ{W7*&4YQ(L;W1dA@hvIOSdrv7WRTm#CU#l!}q0tNB%%Le0GH2_DYx1)7`a z*jrWIrS3z8xy!ow`9;?oSSSFipS*p6FFwYzgl{HSIO)ZBikJczlsJR}`xXS&gGZUf z74z2el_djx>6Xp9DKPgY#w^0ejJB73L+IIe0WtF2h(oD_salwY@xzMaf2M83w|xbC zyruV%^L0R2qFj)NkRTk!14tJ8*LjOD(k%$hzBx$xA4!(c!)1zEl>&(IV1IF0e3DNr z+R6h~glv!9? z#ush&xaHQ?zCNmFw(tkf)MY5i;BNExGmNTx@M^5$P`H3(*qLhpJF;os0}Mh=|8<#?zd}vSXPk)+Q$=@Mi>fB!XZ_ zNSquTmPu8FbqJNqVdj!6d~56LWeAeL9&>&jM``>QLm^Z{(@0sO)|g0)8kP|gjN2d8dpD93pq9h z05mLdvo|oq>?;{QiH)5~qnyA;DSyR`$n~A(Bqhya;TUy1t#AF~cZ@SyPqv!!A5~up z^SfRHSi;po$LZq}Y@yB)<_v^9O1GoEeZj05o?K;l3yj1L!6Hy_XpK#AU0sXs(aca~ z_E=u`u)A#R?YokV`{?pRdCMb^z!7hXGfL_j^i)U1zB!rTPVwrP(QBgT@9D_~t434F z$krXC6=!d-roPu#Sh%xodYs1vL75Wd_&3yZ12 z%}@2kK{)Az=l++c9DvkObb$`VgX{R4xJ74bMzp`FgX6U<$cTtIJMB3CsU=b@Z`YuPo&m}X{x#BzpITw#)#L5j7vzS2Suw7jQlAaWRkf@#u2u6n zQp|$>FeLAx)BKRl>^{lq?YoH=?-xzOmr1C1tgNYQJCkH86T}xMQw9W41qL~385t*c zF68+a{l>@Vp&9J$ft)GmA8Fs6tTsQ`(N@89^U?STo8oo9BEByy5_MVFg!CTm_B}Bg z3`BdyJAY&fK2FJbe1u;iC8RMB@BJ2o{|{j+Z)>ae!z0_f*AEyCc1?B3$uk3Gg<+79 z;nItX3V|LscaZ0ZC@5C}np>LF(@O)|HZ~q9-?mJSKU+x4pexS$Se??81LE zuG)AkQ1$6!uxDU6t zx7XJiM z_}1m#{pIqKol{|MdBNYqBQMjMl=S7$nE62>i0$a?#BFRf`^N*t7P>*!N58Lc`DT88 zR2(BQRykQ&i`KX3Z+=VmDyM(W1>S>G_|(B+_ILdo3=vVbro)AU%-x}ynp#?l?Tux~ zG9T+0?h9hOsRB7h%pI$9TH2&YGuJ#LAi)YWb`EYhd;Jbb*WerVd05Nwe)k z{LFmgsHR=)nX-$(ht|S+h3GMcH(Krn>_Xu&LMTF~ zw>!@}rUWWHVQL@#Zcn{1ecaqw6Tx92`)j(V5=x$E+v!>A%}+WjTcWuy);kn_fEsb- zTwkBJ<}^nPBZ%H!K-w_K)HVL*+;i{j?94z?xGGFWLc+^-vCc|S%|ig3nX^_7R)+`Y z{*#B>DU{oGHOhN9TH3#}#_^`2;}Xl%VrcZT_>4|6zkD%Qs`aYTv9t5lm6|_4Z&$`p zBc4jeAGRlpkx0V`Cftc9H)Lcgs21$}w(F?l)KfV)R2zIB<4fEG;ihHF83c4L5Vkh3 z@zs;mRz8z-fFx(px?0#mcb)<rSI2Ysqd)TsDk`!A88CR4KvZyeSgEN5 zgp`q)KkDjQJ34-^ajMnVjNSsV<;Up8qQ*ugKPhiFyNZ^U0ZT>C*7`Cl%YC{{@k#X* z<{t;(OM$F!}E@ds{#a-iW+Wq{A+rZ z3|3ciRdjrOWXv@iT7I;)e*Fc47PE7t&!g-NY1y_D!^1SbV`FS;B!oFk%DJUD8~l8jbXRxey|du@EPZ~a}QJ{ssmYO*rEQ&muq z;q0?Y_64t@PS->B7huBrr-z5jA3~UVj=6bwffX-WQ!G4v@#oj}Pqf=d$wfBlUG+aA zOeqLcwD#n;LARidoH zVq%sLWVAwpp_0gqiXA8Tv$C;aT0%g)i-;U6dsnTw`*;Xx4_UJVh{gOXhC=6CvOYk_9(Q*bfTNO)Yz^#=$a+ zi@Xo;Fv-x{>rhZ3SA7qgZEX=3-EUtNodZFp3LIcoh5B_`9ewsUtbl^J_cf z?$XkB18B5J6zs8sPd8JlTOc2)6A(-VuTZP&!cnMV;9Hg-NCCgF@EH>`tG~Z!qbr~# z5{m@MVOGN29Gf(`a9cScQT5A-kMF3y zniLnO9M4b>mzL7_FN$X)rRDCXh`hl?L*pm+O48Z0_S{ip9JI6!UsjXIgHSUwzeYq@ z66_li+Hc%t(Nk%Z+E^FgL2P8~L_W*PT(Ollv(p6bUM5hSeV{G-`g+uA$`}p&h33;N zRzX;KJhKGW=L!ox(n|b#Dz7u>5|~zAo>50J$gSH(~m1QJ2j zD=Y8qZ9GKZOzMckA)u0P_sF{s4)%*&*^D1|>t_~z{ld#dbCG8ygGw4`>O^g7_`^V7 zOom4mJ~h~%0)KQD0r<_dv__Cw?P{(`yk%ulFwkRMzxdRsnkU4@%J{wd`yD#MA=l6U61p3XP)PTc)zvamQrqoc^+T2m=Z1FNDt`PZGN0BSv75txs{Q$M zad{mZ11IDpazwWtl%M^|&Ct1oJdci(v6Az5J|e&%vQ|`#WLJClz{bmKR1r&!WJ;PZ za!<*+&E!+;(%4qslGe&@-0KGw7j|rbRV4?ETMrYSqExhkv?qY~r0OwaH#NnSl%yV> zu>T3V+zM-J%S%gt-G2!T2%rql4AhE4^I&6Syt%r{&Cbrae?cZA{fzx)N_P+@wL-%i zA0KE;C3V}0s-Wff>4D~4JUCC}=JD##`0X&Tn>0YQ`WDWQqV?LVs5@}00iP`z zX0SB<^|jaRh9M~S-uqb5F_^lCe1&CZ^6tT zuAIEwT3ES1yC`&Jnk#3R+}zyaxQAAUFx|zZg|!v!e5YUoSuKG95ecnVL11HL<<|T0 zM^Qs;l%hA=nNTlh$3lU8PZf! zT_vx=%MBGsZ%m`EVy*jdHFK5eYj`#IJZeFRvN39Xd%E8SDhYo72APSMz9CP0dnFvR zlBF_NU-)GO74eN-wECgnu{uInsVU#^NaS>N)0Qx>)k0QRHkM}wiIQp=XzU}QN;-{V z6kQC6v$JtnSy&J!)gW@Qy%911a0x|}66k`9?BgE9V}UR;@yEx{NKj3nE-D;E(jG4nJgASEsfmej?Oy)*D*E2Mf`XLt)_YMeuC26hnt~NHf z8nR!3Qo#^8NE^KkL2sl(Uot=Ys(Q^@7nBB-OJg6BZd)?<{3`y)f&jAyV^fItrQ+(GP?NB!R9I987j6 z19c=c>gVSt!AqwbFFyOx(FjrZH=me_ zCryD0j94+FF4CKnsmISoD^mP}y*<#fF!*6jN)a9&K1nb)=B!!10pSZj#Uuh6l7V5G z5}9z#j~`cL5ivFB`2)h`Y^J+>o3CQCwYyD2wR||9L9u$qo4^qnq<^VLf{imZc23YE zC>8R6&>~BI;$kXIOFNpk4AVgX(fa^M8OdW8$YCNcZ!5{NuGm7k^+JMJIQ0zlt` zGt8bwVQqWa1?9a7T-p}Vk$N@ly5p>MNy~V)Z?SO0#ox#D`*DvQ(o4J1zt#_ovz*7@ z8b7H1l#=y-c>#fgu&+~j|9WWo4N)$@z5SPlBlHeVRKoU`ii(rb(Lck(M@zc>V;KRu zj4HvqzP{qK$gUJUQaA&{^Yh2MVXBaFFis2ei&ZQ&oDVjStJ7?%3Q1DN z*cduGTfbdBcwz6(Tbtzzc|(3xPi>{4FPlyKQ0C+th>zGS3<7gIIOlbAitlql2A)G4 z3%1V)FGD6qajfg#_F>XA0-TJcOvqT9FM6UNIIm>PLpsb&S>%Z&Zl38j&lOeVv8kY< z&_qGka<6N)5?-&cJCecLE}6c8uAzj_(-Qw6V%B&%{95Yt+K##er*EpjmB||fm->;j ztu2#G(fw;z%Yd*v*1c}kch&qZ6C)Owr`?-b)l;nag}p<36Gje>HsIJ98)HsqWM_a0 zoG52!c6Efx0KwhJHEhBv@6PT-A{ts+UxmPb@qX%Tk;q|s$HxhmQP!@N#`!|@0TTI$ zA_JEGVk@)LIS8xKnp^IllJ5~tWDIYkFgbF8MF93Q7PVDp0Utru{^S@N27U_s(7+KQ zt0{|xoR{oGM8q#<#%^Qn7Wf|($&whA=vN=K7aX0OD8(*bPP71VKYu8Eguzni)fsv8 z=bSPN`zjgYRDx3lE2t?+Gq&&X5tjRlA+ZSifUnte-;UXiXRk2mDgeeAQ*{@wF!%mk zXT-9g>VD?JdWaE>MeR+BWl;*Qo|1ENl43ip) zd6wQMpCIm&?uXmo;FzmB+S_F-Vn6EX4Q>IHdO}1LuaX<-Zl0dn#eQKwj%sN9*R1z zB0c*XB*s-*R;1Cd=C!~YfL-~=_6!stfW4|J*v2* zTlL~%C}-7D#U0`{%i#KYH>p-y4#e|s$ZLeB^*?_ec&Iu*#^sbI)r*Y}(w3lT*em{k zFowI|q8emmfsNnZA^bIS#Ssum67r15u~P*VDltPv3CRsvR+$88ZDWIqh#2}yuDi61 z*3v)Uw>q_w5vj=S-MO!$Bbv>?=J$LOv4MJw`<6%oKWFDmcQs7dXN3SI+d}6=#Pilv zXMpl&EPyk3!S+tsGu&Dv;O~YoU#~C&yB<_49kyiWjE75x{Dy|Us+~)O7hI^4buc2Q zzxN0)9v=RtVaMZ^FkegLb5U0pChuL^>t6%c7*y@BYAPyo-S;1?+!U`b!lh|(o?v03 zCnm+MtnkxLCxoL|Wr}cVhl4FSs5qsKyTzJ)4OvEGiZkq%Fu63aL}p2$FyT}md$%bY zsJ~E(u`n@hyP6?~`~JD8XLV1+GpuHrzu3JnE`LC}gx}zK;7?E2K^U4Qwl{yf6Irol z&q~$QaQSXQ;3etDR|;-s10B&Qg^YTlyoD%%E(9oMky}x8(=x5nuddezkJbQe=h_Z4)YTQy&I2!q`svVK{-7w zjTq%1I+{^NLtA^o4?Qsf)TbRm1v0hm0_0=eY?U*b*4@y6yc`*}6IGJDTL6B;=e8wb z!mD3lX=&V?Tqwkc2y@e*>IAx?p{X-BH&@njq{iKW*T7v6ddQU?E2*lbAq?Ft7{`PD zrawa+i?k@bb!xKsaB4H)o_ZO#+o+=zIJ@3}=|@s@G!u7g=p7z&VNhMv@i7!%mbEgS zZ;vS@UdjxJJ9!E6^EZCT4)S2QRz0*oR8mSR>1uAOdxu0=bPPIy zD^pGhK#s4j`dOh(CJVq1hY)?_<8;BZJ=%a@qo$e@V6DsFFD6VO)M904_nv~ixb8b* z9SVBa>G zFFwAVjG);X30b_v!BE`XOnztQbV0FBNI)W$Vv4Dbl6XadDxl7s#v)89-`aWVx-TVd zXS3+&nS`Q_Z9su1{t?_A5rYO6V?jh17t2G+Bv>f$<<8rxjQ)e>74B|>3%d2i>A=3D! zjV^EP=-`y8a1-Q0g`?)!nx1B_#y%8beQQO5XD5e;aO>N33;K+COdMC5hC_Uw-2vZ+ z@fijWKjVmdAsuaSCjt%*?uePiuubQ{z0Eqcb?c&BPs^}!;n%_5L95|%3zk6^^a0Q$ zQXQLz1_?QHtCw25%9FEDs5zOk#xO%v@ac_eG=g@K5m0PxzBsBvKHYgA%eqgg=755Z ze@}1}RL`*~e)f)zSoTzf<4X9kwC4sYs;a3`NnAUldi?u~g<_750rKB(>G-O1VEdY5 zTy^2=DT6-w>-Da6KrzIqT$L3{NSe<9)D*Nd_?^$$w35v(k_dDK#T*i@ulu7=Q}@&E zhtoA|u@^o>4VR->l`iKXX!gmtLX!anNJ@67cx4uhXJN5?=pf$iKI9YVrGh9^PLC4= zrolg&Dl3uMp>G&y)pIFnaaK8bdA-QS#>U%O$94|NSUQsCT&@&%mhzYFHhmh;*f##3-nE|Tbg*CT!$C|0$INJELnAB`nZ_L$3+?JFt!kBixK7tQ49ssO1k z(@`2WVE8x@^>tZqPm)Be5k?hTw?Lp!yeFpLV<(t7J~B*3X?XS5{T-^5tWAN#j^aF4 z9$kltAPwJ+M1*V?ZIoe`(A@U0*hPAJ#*Atk_C;Kpj#jvwOCFBiEZd*^y<=o8El0`0 z-*LdM4gvjZ#{IJ=ws$n253C&HB@Z-o=zkRVbhP_N670Q{?+Eeq(c8LdU^K~O=|TLW z6b1pVM9B8d#MLz=X!4&w*KF*@hDbHlJQn&CBG!L!RMN_-th~ug-$KVw(SA%c6On6m zX>EroU}b3ur;dPPtyEbF+3p*unJ!T!*vBPhXH%Dje1?fnHbI2y`P)Zb2nsY@y!-p9 zi{T1aR-2o-<{Cg{+XMd7r_r5{R&db{{em&h5JNC|)I~*w34Fx_9*!!PtVypM(+A7` zUoDFY8`W68fm-@nPcrC{__#QVlBx;MPKrlByuwIS{$Xr`?kMl@7vtH_bp4P6O{Zw* zMR+h)qfjtCI}0~RM&kGINzXd-s{$JxNq*Ela?lzMG~sRf*`Gg5Uy%Yf|DhY=P~-!X zNI)llcYz(=*iGo^BmsI%--@~{p@0dd%cA+Y%ZKN?4UrSyfB<0BADm6{PU?!4BB>nq zk)vp8Z&3UM6WbS68(NJk{4ES6Ma0TNczJDw4w?>JuV*PR)#23~tX8@7(uwmHphoe0h1_o@WQ8e}`_djkXazZ7iv?kC zB3rRia;a~-7xJfo0FS?`&kvR`J^~{rC$K9xf zy2=K}M#s`)5e|i&H!tyt0*9ho84k z?V?xz_)RLWW0I%hXQVB*2k^r`Zf?o>-^EYrLz@4@xa@E7ys7#4IXO( z$$E1f|C6n*YD9lzHMDt2=FB@ts+$|VG{Cx0F Date: Fri, 31 Mar 2023 20:13:54 -0700 Subject: [PATCH 20/45] Misc changes to schedule assignement and loads. --- .../database_files/level_1_space_types.csv | 12 +++---- .../database_files/level_1_space_types.json | 30 ++++++++--------- .../level_2_electric_equipment.csv | 3 ++ .../level_2_electric_equipment.json | 33 +++++++++++++++++++ 4 files changed, 57 insertions(+), 21 deletions(-) diff --git a/data/openstudio_standards_data/database_files/level_1_space_types.csv b/data/openstudio_standards_data/database_files/level_1_space_types.csv index 6a3389fe68..8c243413b2 100644 --- a/data/openstudio_standards_data/database_files/level_1_space_types.csv +++ b/data/openstudio_standards_data/database_files/level_1_space_types.csv @@ -7,11 +7,11 @@ banking,banking_lighting,banking_ventilation,banking_activity_electric_equipment computer room,computer_room_lighting,computer_room_ventilation,computer_room_electric_equipment,,computer_room, "conference, meeting, multipurpose",conference_meeting_multipurpose_lighting,conference_meeting_multipurpose_ventilation,conference_meeting_multipurpose_electric_equipment,,conference_meeting_multipurpose, confinement cells,confinement_cells_lighting,confinement_cells_ventilation,confinement_cells_electric_equipment,,confinement_cells, -"copy, print",copy_print_lighting,copy_print_ventilation,,,, +"copy, print",copy_print_lighting,copy_print_ventilation,office_enclosed_lte_250_sf_electric_equipment,,office_enclosed_lte_250_sf,to be revised corridor,corridor_lighting,corridor_ventilation,corridor_all_other_electric_equipment,,corridor_all_other, courtroom,courtroom_lighting,courtroom_ventilation,courtroom_electric_equipment,,courtroom, -"datacenter, high ite",datacenterhighite_lighting,datacenterhighite_ventilation,datacenter_high_ite_equipment,,, -"datacenter, low ite",datacenterlowite_lighting,datacenterlowite_ventilation,datacenter_low_ite_equipment,,, +"datacenter, high ite",datacenterhighite_lighting,datacenterhighite_ventilation,datacenter_high_ite_equipment,,computer_room,to be revised +"datacenter, low ite",datacenterlowite_lighting,datacenterlowite_ventilation,datacenter_low_ite_equipment,,computer_room,to be revised dining,dining_lighting,dining_ventilation,dining_all_other_electric_equipment,,dining_all_other, dressing room,dressing_room_lighting,dressing_room_ventilation,performing_arts_dressing_room_electric_equipment,,performing_arts_dressing_room, "electrical, mechanical",electrical_mechanical_lighting,electrical_mechanical_ventilation,electrical_mechanical_electric_equipment,,electrical_mechanical, @@ -21,7 +21,7 @@ emergency vehicle garage,emergency_vehicle_garage_lighting,emergency_vehicle_gar exercise area,exercise_area_lighting,exercise_area_ventilation,gymnasium_exercise_area_electric_equipment,,gymnasium_exercise_area, exhibit,exhibit_lighting,exhibit_ventilation,museum_exhibit_area_electric_equipment,,museum_exhibit_area, guest room,guest_room_lighting,guest_room_ventilation,guest_room_electric_equipment,,guest_room, -imaging,imaging_lighting,imaging_ventilation,,,, +imaging,imaging_lighting,imaging_ventilation,imaging_room_equipment,,exam_treatment, interior parking,interior_parking_lighting,interior_parking_ventilation,parking_area_interior_electric_equipment,,parking_area_interior, judges chambers,judges_chambers_lighting,judges_chambers_ventilation,judges_chambers_electric_equipment,,judges_chambers, food preparation,food_preparation_lighting,food_preparation_ventilation,kitchen_electric_equipment,kitchen,kitchen, @@ -29,13 +29,13 @@ laboratory,laboratory_lighting,laboratory_ventilation,laboratory_electric_equipm "laundry, washing",laundry_washing_lighting,laundry_washing_ventilation,laundry_washing_electric_equipment,laundry,laundry_washing, library,library_lighting,library_ventilation,library_stacks_electric_equipment,,library_stacks, living quarters,living_quarters_lighting,living_quarters_ventilation,dormitory_living_quarters_electric_equipment,,dormitory_living_quarters,living quarters such as in a fire station -loading dock,loading_dock_lighting,loading_dock_ventilation,,,, +loading dock,loading_dock_lighting,loading_dock_ventilation,loading_dock_equipment,,workshop,to be revised lobby,lobby_lighting,lobby_ventilation,lobby_all_other_electric_equipment,,lobby_all_other, locker room,locker_room_lighting,locker_room_ventilation,locker_room_electric_equipment,,locker_room, "lounge, breakroom",lounge_breakroom_lighting,lounge_breakroom_ventilation,lounge_breakroom_all_other_electric_equipment,,lounge_breakroom_all_other, manufacturing,manufacturing_lighting,manufacturing_ventilation,manufacturing_low_bay_electric_equipment,,manufacturing_low_bay, medical supply,medical_supply_lighting,medical_supply_ventilation,pharmacy_electric_equipment,,pharmacy, -multifamily,multifamily_lighting,multifamily_ventilation,,,,"common areas in a multifamily building, NOT dwelling units" +multifamily,multifamily_lighting,multifamily_ventilation,multifamily_equipment,,lounge_breakroom_all_other,"common areas in a multifamily building, NOT dwelling units; schedule to be revised" nursery,nursery_lighting,nursery_ventilation,patient_room_electric_equipment,,patient_room, nurses station,nurses_station_lighting,nurses_station_ventilation,nurses_station_electric_equipment,,nurses_station, office,office_lighting,office_ventilation,office_open_electric_equipment,,office_open, diff --git a/data/openstudio_standards_data/database_files/level_1_space_types.json b/data/openstudio_standards_data/database_files/level_1_space_types.json index 83606a7e31..8abeab1094 100644 --- a/data/openstudio_standards_data/database_files/level_1_space_types.json +++ b/data/openstudio_standards_data/database_files/level_1_space_types.json @@ -75,10 +75,10 @@ "space_type_name": "copy, print", "lighting_space_type_name": "copy_print_lighting", "ventilation_space_type_name": "copy_print_ventilation", - "electric_equipment_space_type_name": null, + "electric_equipment_space_type_name": "office_enclosed_lte_250_sf_electric_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": null, - "annotation": null + "schedule_set_name": "office_enclosed_lte_250_sf", + "annotation": "to be revised" }, { "space_type_name": "corridor", @@ -104,8 +104,8 @@ "ventilation_space_type_name": "datacenterhighite_ventilation", "electric_equipment_space_type_name": "datacenter_high_ite_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": null, - "annotation": null + "schedule_set_name": "computer_room", + "annotation": "to be revised" }, { "space_type_name": "datacenter, low ite", @@ -113,8 +113,8 @@ "ventilation_space_type_name": "datacenterlowite_ventilation", "electric_equipment_space_type_name": "datacenter_low_ite_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": null, - "annotation": null + "schedule_set_name": "computer_room", + "annotation": "to be revised" }, { "space_type_name": "dining", @@ -201,9 +201,9 @@ "space_type_name": "imaging", "lighting_space_type_name": "imaging_lighting", "ventilation_space_type_name": "imaging_ventilation", - "electric_equipment_space_type_name": null, + "electric_equipment_space_type_name": "imaging_room_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": null, + "schedule_set_name": "exam_treatment", "annotation": null }, { @@ -273,10 +273,10 @@ "space_type_name": "loading dock", "lighting_space_type_name": "loading_dock_lighting", "ventilation_space_type_name": "loading_dock_ventilation", - "electric_equipment_space_type_name": null, + "electric_equipment_space_type_name": "loading_dock_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": null, - "annotation": null + "schedule_set_name": "workshop", + "annotation": "to be revised" }, { "space_type_name": "lobby", @@ -327,10 +327,10 @@ "space_type_name": "multifamily", "lighting_space_type_name": "multifamily_lighting", "ventilation_space_type_name": "multifamily_ventilation", - "electric_equipment_space_type_name": null, + "electric_equipment_space_type_name": "multifamily_equipment", "natural_gas_equipment_space_type_name": null, - "schedule_set_name": null, - "annotation": "common areas in a multifamily building, NOT dwelling units" + "schedule_set_name": "lounge_breakroom_all_other", + "annotation": "common areas in a multifamily building, NOT dwelling units; schedule to be revised" }, { "space_type_name": "nursery", diff --git a/data/openstudio_standards_data/database_files/level_2_electric_equipment.csv b/data/openstudio_standards_data/database_files/level_2_electric_equipment.csv index 5d396f28d3..258b1fca37 100644 --- a/data/openstudio_standards_data/database_files/level_2_electric_equipment.csv +++ b/data/openstudio_standards_data/database_files/level_2_electric_equipment.csv @@ -94,3 +94,6 @@ plenum_electric_equipment,0,0,0,0,W/ft2,0,0,0 shaft_electric_equipment,0,0,0,0,W/ft2,0,0,0 datacenter_high_ite_equipment,100,300,300,500,W/ft2,0,0.1,0 datacenter_low_ite_equipment,40,70,70,100,W/ft2,0,0.1,0 +multifamily_equipment,0.15,0.15,0.15,0.15,W/ft2,0,0,0 +imaging_room_equipment,0.46,0.46,0.46,0.46,W/ft2,0,0,0 +loading_dock_equipment,0.48,0.48,0.48,0.48,W/ft2,0,0,0 diff --git a/data/openstudio_standards_data/database_files/level_2_electric_equipment.json b/data/openstudio_standards_data/database_files/level_2_electric_equipment.json index 252e65fb48..32096f9140 100644 --- a/data/openstudio_standards_data/database_files/level_2_electric_equipment.json +++ b/data/openstudio_standards_data/database_files/level_2_electric_equipment.json @@ -1043,5 +1043,38 @@ "electric_equipment_fraction_latent": 0, "electric_equipment_fraction_radiant": 0.1, "electric_equipment_fraction_lost": 0 + }, + { + "electric_equipment_space_type_name": "multifamily_equipment", + "electric_equipment_minimum_epd": 0.15, + "electric_equipment_average_epd": 0.15, + "electric_equipment_median_epd": 0.15, + "electric_equipment_maximum_epd": 0.15, + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 + }, + { + "electric_equipment_space_type_name": "imaging_room_equipment", + "electric_equipment_minimum_epd": 0.46, + "electric_equipment_average_epd": 0.46, + "electric_equipment_median_epd": 0.46, + "electric_equipment_maximum_epd": 0.46, + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 + }, + { + "electric_equipment_space_type_name": "loading_dock_equipment", + "electric_equipment_minimum_epd": 0.48, + "electric_equipment_average_epd": 0.48, + "electric_equipment_median_epd": 0.48, + "electric_equipment_maximum_epd": 0.48, + "electric_equipment_epd_unit": "W/ft2", + "electric_equipment_fraction_latent": 0, + "electric_equipment_fraction_radiant": 0, + "electric_equipment_fraction_lost": 0 } ] \ No newline at end of file From 34194bb647cdb0cf22da0bd096271495fc68bb53 Mon Sep 17 00:00:00 2001 From: "Lerond, Jeremy" Date: Fri, 31 Mar 2023 20:45:30 -0700 Subject: [PATCH 21/45] Missing names. --- .../support_electric_equipment_space_type_name_tags.csv | 3 +++ 1 file changed, 3 insertions(+) diff --git a/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.csv b/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.csv index 425e588ac8..7922e7d82b 100644 --- a/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.csv +++ b/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.csv @@ -54,3 +54,6 @@ workshop_electric_equipment worship_pulpit_choir_area_electric_equipment datacenter_high_ite_equipment datacenter_low_ite_equipment +multifamily_equipment +imaging_room_equipment +loading_dock_equipment From 60f5db512ccda2a4b6b58b088da142f00855a400 Mon Sep 17 00:00:00 2001 From: "Lerond, Jeremy" Date: Fri, 31 Mar 2023 20:52:33 -0700 Subject: [PATCH 22/45] Missing names. --- .../support_electric_equipment_space_type_name_tags.json | 9 +++++++++ 1 file changed, 9 insertions(+) diff --git a/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.json b/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.json index 019799b353..8d1e987b7a 100644 --- a/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.json +++ b/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.json @@ -163,5 +163,14 @@ }, { "support_electric_equipment_space_type_name_tags": "datacenter_low_ite_equipment" + }, + { + "support_electric_equipment_space_type_name_tags": "multifamily_equipment" + }, + { + "support_electric_equipment_space_type_name_tags": "imaging_room_equipment" + }, + { + "support_electric_equipment_space_type_name_tags": "loading_dock_equipment" } ] \ No newline at end of file From 4cdb7743f2d3e9fe2ee507e55750b07e77435e39 Mon Sep 17 00:00:00 2001 From: "Lerond, Jeremy" Date: Fri, 31 Mar 2023 21:04:25 -0700 Subject: [PATCH 23/45] Remove CSV files. --- .../database_files/envelope_requirement.csv | 4534 ----------------- .../hvac_minimum_requirement_boilers_90_1.csv | 22 - ...hvac_minimum_requirement_chillers_90_1.csv | 163 - ...hvac_minimum_requirement_furnaces_90_1.csv | 13 - ...mum_requirement_heat_pump_cooling_90_1.csv | 165 - ...mum_requirement_heat_pump_heating_90_1.csv | 51 - ...inimum_requirement_heat_rejection_90_1.csv | 31 - .../hvac_minimum_requirement_motors_90_1.csv | 148 - ...uirement_unitary_air_conditioners_90_1.csv | 196 - ...minimum_requirement_water_heaters_90_1.csv | 25 - ...t_water_source_heat_pumps_cooling_90_1.csv | 19 - ...t_water_source_heat_pumps_heating_90_1.csv | 7 - .../database_files/level_1_space_types.csv | 62 - .../level_2_electric_equipment.csv | 99 - .../level_2_lighting_space_types.csv | 709 --- .../level_2_natural_gas_equipment.csv | 7 - .../level_2_ventilation_space_types.csv | 526 -- .../level_3_lighting_90_1_2004.csv | 127 - .../level_3_lighting_90_1_2007.csv | 130 - .../level_3_lighting_90_1_2010.csv | 134 - .../level_3_lighting_90_1_2013.csv | 144 - .../level_3_lighting_90_1_2016.csv | 143 - .../level_3_lighting_90_1_2019.csv | 140 - .../level_3_ventilation_62_1_1999.csv | 84 - .../level_3_ventilation_62_1_2004.csv | 65 - .../level_3_ventilation_62_1_2007.csv | 76 - .../level_3_ventilation_62_1_2010.csv | 80 - .../level_3_ventilation_62_1_2013.csv | 80 - .../level_3_ventilation_62_1_2016.csv | 80 - .../level_3_ventilation_62_1_2019.csv | 111 - .../database_files/support_constructions.csv | 492 -- ...lectric_equipment_space_type_name_tags.csv | 59 - .../support_lighting_space_type_name_tags.csv | 119 - .../support_lighting_technologies.csv | 2 - .../database_files/support_materials.csv | 1390 ----- .../support_performance_curves.csv | 734 --- .../database_files/support_schedules.csv | 811 --- .../support_standard_templates.csv | 3 - ...pport_ventilation_space_type_name_tags.csv | 99 - .../system_requirement_economizer_90_1.csv | 497 -- ...ystem_requirement_energy_recovery_90_1.csv | 409 -- 41 files changed, 12786 deletions(-) delete mode 100644 data/openstudio_standards_data/database_files/envelope_requirement.csv delete mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_boilers_90_1.csv delete mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_chillers_90_1.csv delete mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_furnaces_90_1.csv delete mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_pump_cooling_90_1.csv delete mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_pump_heating_90_1.csv delete mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_rejection_90_1.csv delete mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_motors_90_1.csv delete mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_unitary_air_conditioners_90_1.csv delete mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_heaters_90_1.csv delete mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1.csv delete mode 100644 data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_source_heat_pumps_heating_90_1.csv delete mode 100644 data/openstudio_standards_data/database_files/level_1_space_types.csv delete mode 100644 data/openstudio_standards_data/database_files/level_2_electric_equipment.csv delete mode 100644 data/openstudio_standards_data/database_files/level_2_lighting_space_types.csv delete mode 100644 data/openstudio_standards_data/database_files/level_2_natural_gas_equipment.csv delete mode 100644 data/openstudio_standards_data/database_files/level_2_ventilation_space_types.csv delete mode 100644 data/openstudio_standards_data/database_files/level_3_lighting_90_1_2004.csv delete mode 100644 data/openstudio_standards_data/database_files/level_3_lighting_90_1_2007.csv delete mode 100644 data/openstudio_standards_data/database_files/level_3_lighting_90_1_2010.csv delete mode 100644 data/openstudio_standards_data/database_files/level_3_lighting_90_1_2013.csv delete mode 100644 data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.csv delete mode 100644 data/openstudio_standards_data/database_files/level_3_lighting_90_1_2019.csv delete mode 100644 data/openstudio_standards_data/database_files/level_3_ventilation_62_1_1999.csv delete mode 100644 data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2004.csv delete mode 100644 data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2007.csv delete mode 100644 data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2010.csv delete mode 100644 data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2013.csv delete mode 100644 data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2016.csv delete mode 100644 data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.csv delete mode 100644 data/openstudio_standards_data/database_files/support_constructions.csv delete mode 100644 data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.csv delete mode 100644 data/openstudio_standards_data/database_files/support_lighting_space_type_name_tags.csv delete mode 100644 data/openstudio_standards_data/database_files/support_lighting_technologies.csv delete mode 100644 data/openstudio_standards_data/database_files/support_materials.csv delete mode 100644 data/openstudio_standards_data/database_files/support_performance_curves.csv delete mode 100644 data/openstudio_standards_data/database_files/support_schedules.csv delete mode 100644 data/openstudio_standards_data/database_files/support_standard_templates.csv delete mode 100644 data/openstudio_standards_data/database_files/support_ventilation_space_type_name_tags.csv delete mode 100644 data/openstudio_standards_data/database_files/system_requirement_economizer_90_1.csv delete mode 100644 data/openstudio_standards_data/database_files/system_requirement_energy_recovery_90_1.csv diff --git a/data/openstudio_standards_data/database_files/envelope_requirement.csv b/data/openstudio_standards_data/database_files/envelope_requirement.csv deleted file mode 100644 index 02c51b2614..0000000000 --- a/data/openstudio_standards_data/database_files/envelope_requirement.csv +++ /dev/null @@ -1,4534 +0,0 @@ -template,climate_zone_set,intended_surface_type,standards_construction_type,building_category,construction,orientation,minimum_percent_of_surface,maximum_percent_of_surface,assembly_maximum_u_value,u_value_includes_interior_film_coefficient,u_value_includes_exterior_film_coefficient,assembly_maximum_f_factor,assembly_maximum_c_factor,assembly_maximum_solar_heat_gain_coefficient,assembly_minimum_vt_shgc,annotation -90.1-2004,ClimateZone 1,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 1,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,1.282,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.614,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,1.28,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2004,ClimateZone 1,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,1.18,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 2,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.167,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2004,ClimateZone 2,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.184,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.17 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.17,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 2,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 2,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 2,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 2,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 2,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 2,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 2,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 2,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 2,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 2,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 2,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 2,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.34 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 2,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 2,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 2,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 2,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 3A,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 3B,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 3C,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 3,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2004,ClimateZone 3A,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2004,ClimateZone 3B,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2004,ClimateZone 3C,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2004,ClimateZone 3,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2004,ClimateZone 3A,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2004,ClimateZone 3B,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2004,ClimateZone 3C,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2004,ClimateZone 3,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 3A,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 3B,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 3C,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 3A,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.184,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 3A,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 3A,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 3A,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 3A,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 3A,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 3A,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 3A,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 3A,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 3A,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.39 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.36 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.34 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.34,, -90.1-2004,ClimateZone 3A,Skylight,Plastic with Curb,Nonresidential,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.27,, -90.1-2004,ClimateZone 3A,Skylight,Plastic with Curb,Residential,U 1.30 SHGC 0.27 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.27,, -90.1-2004,ClimateZone 3A,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.39 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3A,Skylight,Without Curb,Residential,U 0.69 SHGC 0.36 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 3A,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3B,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.184,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.19 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 3B,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 3B,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 3B,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 3B,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 3B,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 3B,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 3B,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 3B,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 3B,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.39 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3B,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.36 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,Skylight,Plastic with Curb,Nonresidential,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3B,Skylight,Plastic with Curb,Residential,U 1.30 SHGC 0.27 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 3B,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3B,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.39 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,Skylight,Without Curb,Residential,U 0.69 SHGC 0.36 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3B,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.65,, -90.1-2004,ClimateZone 3C,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.184,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.61,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.61,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.61,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Residential,U 0.72 SHGC 0.25 Simple Glazing Window,,40.001,100,0.72,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.72 SHGC 0.25 Simple Glazing Window,,40.001,100,0.72,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Residential,U 0.72 SHGC 0.25 Simple Glazing Window,,40.001,100,0.72,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.61,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.61 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.61,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.39 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.34 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.34,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Residential,U 0.72 SHGC 0.25 Simple Glazing Window,,40.001,100,0.72,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 3C,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 3C,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 3C,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 3C,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 3C,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 3C,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 3C,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 3C,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 3C,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.61 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.27,, -90.1-2004,ClimateZone 3C,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.39 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.27,, -90.1-2004,ClimateZone 3C,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.39 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.65 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.65 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 3C,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 3C,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.61 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 3C,Skylight,Without Curb,Residential,U 1.36 SHGC 0.39 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 3C,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 4,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2004,ClimateZone 4,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.134,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.25 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 4,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.95,,,, -90.1-2004,ClimateZone 4,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 4,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.84,,,, -90.1-2004,ClimateZone 4,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 4,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 4,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 4,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 4,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 4,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 4,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 4,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.36 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 4,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 4,Skylight,Plastic with Curb,Nonresidential,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,Skylight,Plastic with Curb,Residential,U 1.30 SHGC 0.62 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 4,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.65,, -90.1-2004,ClimateZone 4,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.27,, -90.1-2004,ClimateZone 4,Skylight,Without Curb,Residential,U 0.58 SHGC 0.36 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,0.27,, -90.1-2004,ClimateZone 4,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 5,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2004,ClimateZone 5,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 5,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.84,,,, -90.1-2004,ClimateZone 5,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 5,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.84,,,, -90.1-2004,ClimateZone 5,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 5,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 5,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 5,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 5,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 5,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 5,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.36 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 5,Skylight,Plastic with Curb,Nonresidential,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 5,Skylight,Plastic with Curb,Residential,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 5,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.61,, -90.1-2004,ClimateZone 5,Skylight,Without Curb,Residential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 5,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 6,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.0066,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 6,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2004,ClimateZone 6,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.39 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.26 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.26,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 6,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.84,,,, -90.1-2004,ClimateZone 6,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 6,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.78,,,, -90.1-2004,ClimateZone 6,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 6,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 6,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 6,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 6,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2004,ClimateZone 6,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 6,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.45 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.65 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.65,, -90.1-2004,ClimateZone 6,Skylight,Plastic with Curb,Nonresidential,U 0.87 SHGC 0.71 Simple Glazing Skylight,,0,2,0.87,TRUE,TRUE,,,0.65,, -90.1-2004,ClimateZone 6,Skylight,Plastic with Curb,Residential,U 0.74 SHGC 0.65 Simple Glazing Skylight,,0,2,0.74,TRUE,TRUE,,,0.34,, -90.1-2004,ClimateZone 6,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 6,Skylight,Without Curb,Residential,U 0.58 SHGC 0.61 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,0.61,, -90.1-2004,ClimateZone 6,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.39,, -90.1-2004,ClimateZone 7,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 7,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2004,ClimateZone 7,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,1,10,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,10.001,20,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,20.001,30,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.57 SHGC 0.49 Simple Glazing Window,,30.001,40,0.57,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.36 Simple Glazing Window,,40.001,100,0.46,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 7,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.84,,,, -90.1-2004,ClimateZone 7,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, -90.1-2004,ClimateZone 7,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.78,,,, -90.1-2004,ClimateZone 7,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 7,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 7,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 7,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2004,ClimateZone 7,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2004,ClimateZone 7,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 7,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.68 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 7,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.64 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,Skylight,Plastic with Curb,Nonresidential,U 0.87 SHGC 0.77 Simple Glazing Skylight,,0,2,0.87,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 7,Skylight,Plastic with Curb,Residential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 7,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 7,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.68 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,Skylight,Without Curb,Residential,U 0.69 SHGC 0.64 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 7,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.65,, -90.1-2004,ClimateZone 8,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 8,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.072,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2004,ClimateZone 8,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.055,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,1,10,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,10.001,20,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,20.001,30,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.46 SHGC 0.45 Simple Glazing Window,,30.001,40,0.46,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,40.001,100,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, -90.1-2004,ClimateZone 8,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.78,,,, -90.1-2004,ClimateZone 8,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2004,ClimateZone 8,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.78,,,, -90.1-2004,ClimateZone 8,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 8,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.95,,,, -90.1-2004,ClimateZone 8,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 8,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2004,ClimateZone 8,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2004,ClimateZone 8,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 8,Skylight,Glass with Curb,Nonresidential,U 0.98 SHGC 0.62 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.62,, -90.1-2004,ClimateZone 8,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.27 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.27,, -90.1-2004,ClimateZone 8,Skylight,Glass with Curb,Semiheated,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,Skylight,Plastic with Curb,Nonresidential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,Skylight,Plastic with Curb,Residential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,0.49,, -90.1-2004,ClimateZone 8,Skylight,Plastic with Curb,Semiheated,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 8,Skylight,Without Curb,Nonresidential,U 0.58 SHGC 0.19 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 8,Skylight,Without Curb,Residential,U 0.58 SHGC 0.45 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 8,Skylight,Without Curb,Semiheated,U 0.81 SHGC 0.65 Simple Glazing Skylight,,0,2,0.81,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 1,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 1,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 1,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 1,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 1,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 1,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 1,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 1,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 1,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 1,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.36 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 1,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 1,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.16 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.16,, -90.1-2004,ClimateZone 1,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.34 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 1,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.34,, -90.1-2004,ClimateZone 1,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.27,, -90.1-2004,ClimateZone 1,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.27,, -90.1-2004,ClimateZone 1,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 1,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.065,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.063,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.65,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,1.28,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2007,ClimateZone 1,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 2,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.167,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2007,ClimateZone 2,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.184,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2007,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.7 SHGC 0.25 Simple Glazing Window,,,,0.7,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.7 SHGC 0.25 Simple Glazing Window,,,,0.7,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 2,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2007,ClimateZone 2,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 2,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2007,ClimateZone 2,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 2,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2007,ClimateZone 2,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 2,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 2,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 2,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 2,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.49,, -90.1-2007,ClimateZone 2,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.49 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.49,, -90.1-2007,ClimateZone 2,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.39,, -90.1-2007,ClimateZone 2,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 2,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.49,, -90.1-2007,ClimateZone 2,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.46,, -90.1-2007,ClimateZone 2,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.36,, -90.1-2007,ClimateZone 3,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 3,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2007,ClimateZone 3,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.184,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2007,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 3,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 3,ExteriorWindow,Metal framing (all other),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.9 SHGC 0.25 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 3,GlassDoor,Metal framing (entrance door),Residential,U 0.9 SHGC 0.25 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 3,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 3,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2007,ClimateZone 3,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 3,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.09,,,, -90.1-2007,ClimateZone 3,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 3,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2007,ClimateZone 3,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 3,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 3,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 3,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 3,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.39 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.36 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.71 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.71,, -90.1-2007,ClimateZone 3,Skylight,Plastic with Curb,Nonresidential,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.65,, -90.1-2007,ClimateZone 3,Skylight,Plastic with Curb,Residential,U 1.30 SHGC 0.27 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.55,, -90.1-2007,ClimateZone 3,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.39 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 3,Skylight,Without Curb,Residential,U 0.69 SHGC 0.36 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.49,, -90.1-2007,ClimateZone 3,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.49,, -90.1-2007,ClimateZone 4,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 4,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2007,ClimateZone 4,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.134,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2007,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.4 SHGC 0.4 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.4 SHGC 0.4 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.85 SHGC 0.4 Simple Glazing Window,,,,0.85,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.85 SHGC 0.4 Simple Glazing Window,,,,0.85,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 4,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2007,ClimateZone 4,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, -90.1-2007,ClimateZone 4,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2007,ClimateZone 4,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 4,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2007,ClimateZone 4,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 4,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 4,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2007,ClimateZone 4,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 4,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.39,, -90.1-2007,ClimateZone 4,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.36 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,Skylight,Plastic with Curb,Nonresidential,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.68,, -90.1-2007,ClimateZone 4,Skylight,Plastic with Curb,Residential,U 1.30 SHGC 0.62 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.64,, -90.1-2007,ClimateZone 4,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.64,, -90.1-2007,ClimateZone 4,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,Skylight,Without Curb,Residential,U 0.58 SHGC 0.36 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 4,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.77,, -90.1-2007,ClimateZone 5,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 5,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.119,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2007,ClimateZone 5,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2007,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 5,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2007,ClimateZone 5,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, -90.1-2007,ClimateZone 5,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2007,ClimateZone 5,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 5,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2007,ClimateZone 5,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 5,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2007,ClimateZone 5,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2007,ClimateZone 5,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 5,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.77,, -90.1-2007,ClimateZone 5,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.77,, -90.1-2007,ClimateZone 5,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,Skylight,Plastic with Curb,Nonresidential,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,Skylight,Plastic with Curb,Residential,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,0.68,, -90.1-2007,ClimateZone 5,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.64,, -90.1-2007,ClimateZone 5,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.64,, -90.1-2007,ClimateZone 5,Skylight,Without Curb,Residential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 5,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 6,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2007,ClimateZone 6,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2007,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.6 SHGC 0.45 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, -90.1-2007,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 0.9 SHGC 0.45 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, -90.1-2007,ClimateZone 6,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2007,ClimateZone 6,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2007,ClimateZone 6,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2007,ClimateZone 6,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 6,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2007,ClimateZone 6,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 6,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2007,ClimateZone 6,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2007,ClimateZone 6,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 6,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.45 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,Skylight,Plastic with Curb,Nonresidential,U 0.87 SHGC 0.71 Simple Glazing Skylight,,0,2,0.87,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,Skylight,Plastic with Curb,Residential,U 0.74 SHGC 0.65 Simple Glazing Skylight,,0,2,0.74,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,Skylight,Without Curb,Residential,U 0.58 SHGC 0.45 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 6,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 7,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2007,ClimateZone 7,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.042,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2007,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.45,, -90.1-2007,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,, -90.1-2007,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.45,, -90.1-2007,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.6 SHGC 0.45 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.45,, -90.1-2007,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 0.9 SHGC 0.45 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2007,ClimateZone 7,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.843,,,, -90.1-2007,ClimateZone 7,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2007,ClimateZone 7,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2007,ClimateZone 7,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 7,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2007,ClimateZone 7,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 7,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2007,ClimateZone 7,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, -90.1-2007,ClimateZone 7,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 7,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.68 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.64 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,Skylight,Plastic with Curb,Nonresidential,U 0.87 SHGC 0.77 Simple Glazing Skylight,,0,2,0.87,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,Skylight,Plastic with Curb,Residential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 7,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.68 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.36,, -90.1-2007,ClimateZone 7,Skylight,Without Curb,Residential,U 0.69 SHGC 0.64 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.19,, -90.1-2007,ClimateZone 7,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.16,, -90.1-2007,ClimateZone 8,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 8,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.072,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2007,ClimateZone 8,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.036,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.052,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.036,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2007,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.45,, -90.1-2007,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,, -90.1-2007,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.45,, -90.1-2007,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.6 SHGC 0.45 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.45,, -90.1-2007,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 0.9 SHGC 0.45 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2007,ClimateZone 8,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2007,ClimateZone 8,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.51,,,, -90.1-2007,ClimateZone 8,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2007,ClimateZone 8,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 8,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2007,ClimateZone 8,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 8,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2007,ClimateZone 8,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.075,,, -90.1-2007,ClimateZone 8,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 8,Skylight,Glass with Curb,Nonresidential,U 0.98 SHGC 0.45 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.45 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,Skylight,Glass with Curb,Semiheated,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.34,, -90.1-2007,ClimateZone 8,Skylight,Plastic with Curb,Nonresidential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,0.27,, -90.1-2007,ClimateZone 8,Skylight,Plastic with Curb,Residential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,0.27,, -90.1-2007,ClimateZone 8,Skylight,Plastic with Curb,Semiheated,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,Skylight,Without Curb,Nonresidential,U 0.58 SHGC 0.45 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 8,Skylight,Without Curb,Residential,U 0.58 SHGC 0.36 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,0.36,, -90.1-2007,ClimateZone 8,Skylight,Without Curb,Semiheated,U 0.81 SHGC 0.65 Simple Glazing Skylight,,0,2,0.81,TRUE,TRUE,,,0.19,, -90.1-2007,ClimateZone 1,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,1.18,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2007,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 1,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2007,ClimateZone 1,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 1,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2007,ClimateZone 1,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 1,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2007,ClimateZone 1,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 1,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 1,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 1,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 1,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.49 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.49,, -90.1-2007,ClimateZone 1,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.49,, -90.1-2007,ClimateZone 1,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.39 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.39,, -90.1-2007,ClimateZone 1,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.34 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 1,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.77,, -90.1-2007,ClimateZone 1,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.77,, -90.1-2007,ClimateZone 1,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.62,, -90.1-2007,ClimateZone 1,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 1,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.065,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.063,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.065,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.167,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2010,ClimateZone 1,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.093,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 2,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2010,ClimateZone 2,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.093,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.093,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2010,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.7 SHGC 0.25 Simple Glazing Window,,,,0.7,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.7 SHGC 0.25 Simple Glazing Window,,,,0.7,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 0.75 SHGC 0.25 Simple Glazing Window,,,,0.75,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 2,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2010,ClimateZone 2,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2010,ClimateZone 2,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2010,ClimateZone 2,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 2,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 2,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 2,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 2,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 2,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 2,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 2,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.27 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.27,, -90.1-2010,ClimateZone 2,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.27,, -90.1-2010,ClimateZone 2,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.36,, -90.1-2010,ClimateZone 2,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, -90.1-2010,ClimateZone 2,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.19,, -90.1-2010,ClimateZone 2,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 2,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 3,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2010,ClimateZone 3,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2010,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 3,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 3,ExteriorWindow,Metal framing (all other),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.9 SHGC 0.25 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 3,GlassDoor,Metal framing (entrance door),Residential,U 0.9 SHGC 0.25 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 3,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,GroundContactFloor,Unheated,Nonresidential,Smallhotel 2010 Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 3,GroundContactFloor,Heated,Nonresidential,Smallhotel 2010 Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2010,ClimateZone 3,GroundContactFloor,Unheated,Residential,Smallhotel 2010 Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 3,GroundContactFloor,Heated,Residential,Smallhotel 2010 Slab Floor,,,,,TRUE,TRUE,0.09,,,, -90.1-2010,ClimateZone 3,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 3,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2010,ClimateZone 3,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 3,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 3,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 3,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 3,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.39 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.39,, -90.1-2010,ClimateZone 3,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.36 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.36,, -90.1-2010,ClimateZone 3,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.19,, -90.1-2010,ClimateZone 3,Skylight,Plastic with Curb,Nonresidential,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,Skylight,Plastic with Curb,Residential,U 1.30 SHGC 0.27 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 3,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.65,, -90.1-2010,ClimateZone 3,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.39 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.27,, -90.1-2010,ClimateZone 3,Skylight,Without Curb,Residential,U 0.69 SHGC 0.36 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.27,, -90.1-2010,ClimateZone 3,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 4,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.097,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2010,ClimateZone 4,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2010,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.4 SHGC 0.4 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.4 SHGC 0.4 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.85 SHGC 0.4 Simple Glazing Window,,,,0.85,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.85 SHGC 0.4 Simple Glazing Window,,,,0.85,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 4,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2010,ClimateZone 4,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, -90.1-2010,ClimateZone 4,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2010,ClimateZone 4,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 4,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2010,ClimateZone 4,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 4,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 4,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2010,ClimateZone 4,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 4,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.36 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.39,, -90.1-2010,ClimateZone 4,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.36 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.36,, -90.1-2010,ClimateZone 4,Skylight,Plastic with Curb,Nonresidential,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.19,, -90.1-2010,ClimateZone 4,Skylight,Plastic with Curb,Residential,U 1.30 SHGC 0.62 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 4,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.49,, -90.1-2010,ClimateZone 4,Skylight,Without Curb,Residential,U 0.58 SHGC 0.36 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,0.36,, -90.1-2010,ClimateZone 4,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.19,, -90.1-2010,ClimateZone 5,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 5,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.055,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.119,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.083,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2010,ClimateZone 5,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.069,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.069,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2010,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 5,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2010,ClimateZone 5,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, -90.1-2010,ClimateZone 5,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2010,ClimateZone 5,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 5,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2010,ClimateZone 5,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 5,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2010,ClimateZone 5,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2010,ClimateZone 5,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 5,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.45 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.65 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.65,, -90.1-2010,ClimateZone 5,Skylight,Plastic with Curb,Nonresidential,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,0.62,, -90.1-2010,ClimateZone 5,Skylight,Plastic with Curb,Residential,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,0.27,, -90.1-2010,ClimateZone 5,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 5,Skylight,Without Curb,Residential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.49,, -90.1-2010,ClimateZone 5,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.36,, -90.1-2010,ClimateZone 6,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 6,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.072,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2010,ClimateZone 6,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.069,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.069,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2010,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.45 SHGC 0.4 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.55 SHGC 0.4 Simple Glazing Window,,,,0.55,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.6 SHGC 0.45 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.4 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.4,, -90.1-2010,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 0.9 SHGC 0.45 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, -90.1-2010,ClimateZone 6,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2010,ClimateZone 6,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2010,ClimateZone 6,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2010,ClimateZone 6,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 6,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2010,ClimateZone 6,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 6,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2010,ClimateZone 6,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2010,ClimateZone 6,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 6,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.49 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.19,, -90.1-2010,ClimateZone 6,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.45 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,Skylight,Plastic with Curb,Nonresidential,U 0.87 SHGC 0.71 Simple Glazing Skylight,,0,2,0.87,TRUE,TRUE,,,0.49,, -90.1-2010,ClimateZone 6,Skylight,Plastic with Curb,Residential,U 0.74 SHGC 0.65 Simple Glazing Skylight,,0,2,0.74,TRUE,TRUE,,,0.49,, -90.1-2010,ClimateZone 6,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.39,, -90.1-2010,ClimateZone 6,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.49 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,Skylight,Without Curb,Residential,U 0.58 SHGC 0.45 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 6,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.77,, -90.1-2010,ClimateZone 7,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 7,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.049,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.072,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2010,ClimateZone 7,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.042,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2010,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.45,, -90.1-2010,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,, -90.1-2010,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.45,, -90.1-2010,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.6 SHGC 0.45 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.45,, -90.1-2010,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 0.9 SHGC 0.45 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2010,ClimateZone 7,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.843,,,, -90.1-2010,ClimateZone 7,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2010,ClimateZone 7,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2010,ClimateZone 7,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 7,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2010,ClimateZone 7,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 7,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2010,ClimateZone 7,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, -90.1-2010,ClimateZone 7,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 7,Skylight,Glass with Curb,Nonresidential,U 1.17 SHGC 0.68 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.77,, -90.1-2010,ClimateZone 7,Skylight,Glass with Curb,Residential,U 1.17 SHGC 0.64 Simple Glazing Skylight,,0,2,1.17,TRUE,TRUE,,,0.62,, -90.1-2010,ClimateZone 7,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,Skylight,Plastic with Curb,Nonresidential,U 0.87 SHGC 0.77 Simple Glazing Skylight,,0,2,0.87,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,Skylight,Plastic with Curb,Residential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,0.49,, -90.1-2010,ClimateZone 7,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.49,, -90.1-2010,ClimateZone 7,Skylight,Without Curb,Nonresidential,U 0.69 SHGC 0.68 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,0.39,, -90.1-2010,ClimateZone 7,Skylight,Without Curb,Residential,U 0.69 SHGC 0.64 Simple Glazing Skylight,,0,2,0.69,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 7,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 8,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.035,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.035,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2010,ClimateZone 8,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.036,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.052,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.057,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.036,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2010,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.45,, -90.1-2010,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,, -90.1-2010,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.45,, -90.1-2010,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.45 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.6 SHGC 0.45 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,0.45,, -90.1-2010,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.8 SHGC 0.45 Simple Glazing Window,,,,0.8,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 0.9 SHGC 0.45 Simple Glazing Window,,,,0.9,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2010,ClimateZone 8,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2010,ClimateZone 8,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.51,,,, -90.1-2010,ClimateZone 8,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2010,ClimateZone 8,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 8,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2010,ClimateZone 8,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 8,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2010,ClimateZone 8,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.075,,, -90.1-2010,ClimateZone 8,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 8,Skylight,Glass with Curb,Nonresidential,U 0.98 SHGC 0.49 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.49,, -90.1-2010,ClimateZone 8,Skylight,Glass with Curb,Residential,U 0.98 SHGC 0.46 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.46,, -90.1-2010,ClimateZone 8,Skylight,Glass with Curb,Semiheated,U 1.30 SHGC 0.65 Simple Glazing Skylight,,0,2,1.3,TRUE,TRUE,,,0.36,, -90.1-2010,ClimateZone 8,Skylight,Plastic with Curb,Nonresidential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,Skylight,Plastic with Curb,Residential,U 0.61 SHGC 0.77 Simple Glazing Skylight,,0,2,0.61,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 8,Skylight,Plastic with Curb,Semiheated,U 1.10 SHGC 0.77 Simple Glazing Skylight,,0,2,1.1,TRUE,TRUE,,,0.71,, -90.1-2010,ClimateZone 8,Skylight,Without Curb,Nonresidential,U 0.58 SHGC 0.65 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,0.65,, -90.1-2010,ClimateZone 8,Skylight,Without Curb,Residential,U 0.58 SHGC 0.55 Simple Glazing Skylight,,0,2,0.58,TRUE,TRUE,,,0.55,, -90.1-2010,ClimateZone 8,Skylight,Without Curb,Semiheated,U 0.81 SHGC 0.65 Simple Glazing Skylight,,0,2,0.81,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.093,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2010,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 1,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 1,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2010,ClimateZone 1,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 1,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2010,ClimateZone 1,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 1,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2010,ClimateZone 1,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 1,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 1,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 1,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 1,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.19,, -90.1-2010,ClimateZone 1,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.34 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.36,, -90.1-2010,ClimateZone 1,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, -90.1-2010,ClimateZone 1,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, -90.1-2010,ClimateZone 1,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 1,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.39,, -90.1-2013,ClimateZone 1,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 1,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.1156,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2013,ClimateZone 1,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 2,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.096,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2013,ClimateZone 2,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2013,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.4 SHGC 0.25 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.83 SHGC 0.25 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 0.4 SHGC 0.25 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 0.77 SHGC 0.25 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.93 SHGC 0.45 Simple Glazing Window,,,,0.93,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 0.83 SHGC 0.45 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 2,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2013,ClimateZone 2,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 2,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2013,ClimateZone 2,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 2,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2013,ClimateZone 2,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 2,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2013,ClimateZone 2,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2013,ClimateZone 2,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2013,ClimateZone 2,Skylight,Glass with Curb,Nonresidential,U 0.65 SHGC 0.45 Simple Glazing Skylight,,0,2,0.65,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,Skylight,Glass with Curb,Residential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,0,2,0.65,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,Skylight,Glass with Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,0.77,, -90.1-2013,ClimateZone 2,Skylight,Plastic with Curb,Nonresidential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,0,2,0.65,TRUE,TRUE,,,0.77,, -90.1-2013,ClimateZone 2,Skylight,Plastic with Curb,Residential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,0,2,0.65,TRUE,TRUE,,,0.77,, -90.1-2013,ClimateZone 2,Skylight,Plastic with Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,Skylight,Without Curb,Nonresidential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,0,2,0.65,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 2,Skylight,Without Curb,Residential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,0,2,0.65,TRUE,TRUE,,,0.68,, -90.1-2013,ClimateZone 2,Skylight,Without Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,0.64,, -90.1-2013,ClimateZone 3,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 3,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.119,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.096,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2013,ClimateZone 3,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.077,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.072,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2013,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.25 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 3,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.25 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.25 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 3,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.25 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.87 SHGC 0.45 Simple Glazing Window,,,,0.87,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 3,GlassDoor,Metal framing (entrance door),Residential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 3,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 3,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2013,ClimateZone 3,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, -90.1-2013,ClimateZone 3,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2013,ClimateZone 3,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 3,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2013,ClimateZone 3,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 3,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2013,ClimateZone 3,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2013,ClimateZone 3,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2013,ClimateZone 3,Skylight,Glass with Curb,Nonresidential,U 0.55 SHGC 0.64 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,0.64,, -90.1-2013,ClimateZone 3,Skylight,Glass with Curb,Residential,U 0.55 SHGC 0.45 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,Skylight,Glass with Curb,Semiheated,U 1.70 SHGC 0.36 Simple Glazing Skylight,,0,2,1.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,Skylight,Plastic with Curb,Nonresidential,U 0.55 SHGC 0.45 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,Skylight,Plastic with Curb,Residential,U 0.55 SHGC 0.45 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,Skylight,Plastic with Curb,Semiheated,U 1.70 SHGC 0.36 Simple Glazing Skylight,,0,2,1.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,Skylight,Without Curb,Nonresidential,U 0.55 SHGC 0.45 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,Skylight,Without Curb,Residential,U 0.55 SHGC 0.45 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 3,Skylight,Without Curb,Semiheated,U 1.70 SHGC 0.36 Simple Glazing Skylight,,0,2,1.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 4,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.082,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2013,ClimateZone 4,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.06,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2013,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.42 SHGC 0.4 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.35 SHGC 0.4 Simple Glazing Window,,,,0.35,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.42 SHGC 0.4 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.4 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.51 SHGC 0.45 Simple Glazing Window,,,,0.51,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.73 SHGC 0.45 Simple Glazing Window,,,,0.73,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.4 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 0.81 SHGC 0.45 Simple Glazing Window,,,,0.81,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2013,ClimateZone 4,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.843,,,, -90.1-2013,ClimateZone 4,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2013,ClimateZone 4,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2013,ClimateZone 4,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 4,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2013,ClimateZone 4,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 4,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2013,ClimateZone 4,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, -90.1-2013,ClimateZone 4,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2013,ClimateZone 4,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,Skylight,Glass with Curb,Semiheated,U 1.15 SHGC 0.77 Simple Glazing Skylight,,0,2,1.15,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,Skylight,Plastic with Curb,Semiheated,U 1.15 SHGC 0.77 Simple Glazing Skylight,,0,2,1.15,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,Skylight,Without Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 4,Skylight,Without Curb,Semiheated,U 1.15 SHGC 0.77 Simple Glazing Skylight,,0,2,1.15,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 5,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.082,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2013,ClimateZone 5,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.055,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.055,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2013,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.32 SHGC 0.4 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.42 SHGC 0.4 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.32 SHGC 0.4 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.42 SHGC 0.4 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.4 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.62 SHGC 0.45 Simple Glazing Window,,,,0.62,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.4 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 0.7 SHGC 0.45 Simple Glazing Window,,,,0.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2013,ClimateZone 5,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2013,ClimateZone 5,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.51,,,, -90.1-2013,ClimateZone 5,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2013,ClimateZone 5,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 5,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2013,ClimateZone 5,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 5,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2013,ClimateZone 5,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, -90.1-2013,ClimateZone 5,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2013,ClimateZone 5,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.36 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.36,, -90.1-2013,ClimateZone 5,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.19 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.19,, -90.1-2013,ClimateZone 5,Skylight,Glass with Curb,Semiheated,U 0.98 SHGC 0.45 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.34 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.34,, -90.1-2013,ClimateZone 5,Skylight,Plastic with Curb,Semiheated,U 0.98 SHGC 0.27 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.27,, -90.1-2013,ClimateZone 5,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,Skylight,Without Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 5,Skylight,Without Curb,Semiheated,U 0.98 SHGC 0.36 Simple Glazing Skylight,,0,2,0.98,TRUE,TRUE,,,0.36,, -90.1-2013,ClimateZone 6,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 6,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.031,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.06,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2013,ClimateZone 6,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2013,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.32 SHGC 0.4 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.42 SHGC 0.4 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.4 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.32 SHGC 0.4 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.42 SHGC 0.4 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.4 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.51 SHGC 0.45 Simple Glazing Window,,,,0.51,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2013,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 0.59 SHGC 0.45 Simple Glazing Window,,,,0.59,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.51,,,, -90.1-2013,ClimateZone 6,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2013,ClimateZone 6,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.434,,,, -90.1-2013,ClimateZone 6,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.671,,,, -90.1-2013,ClimateZone 6,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 6,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2013,ClimateZone 6,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 6,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, -90.1-2013,ClimateZone 6,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2013,ClimateZone 6,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2013,ClimateZone 6,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.19 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.19,, -90.1-2013,ClimateZone 6,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,Skylight,Glass with Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.36 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.36,, -90.1-2013,ClimateZone 6,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.19 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.19,, -90.1-2013,ClimateZone 6,Skylight,Plastic with Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,0.19,, -90.1-2013,ClimateZone 6,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,Skylight,Without Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 6,Skylight,Without Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,0.39,, -90.1-2013,ClimateZone 7,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.042,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.042,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.27,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 7,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.039,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2013,ClimateZone 7,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.044,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.044,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.042,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.072,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2013,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.51,,,, -90.1-2013,ClimateZone 7,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.671,,,, -90.1-2013,ClimateZone 7,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.434,,,, -90.1-2013,ClimateZone 7,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.671,,,, -90.1-2013,ClimateZone 7,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 7,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2013,ClimateZone 7,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 7,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2013,ClimateZone 7,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2013,ClimateZone 7,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2013,ClimateZone 7,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.27 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.27,, -90.1-2013,ClimateZone 7,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.27 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.27,, -90.1-2013,ClimateZone 7,Skylight,Glass with Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.36 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.36,, -90.1-2013,ClimateZone 7,Skylight,Plastic with Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,0.19,, -90.1-2013,ClimateZone 7,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.19 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.19,, -90.1-2013,ClimateZone 7,Skylight,Without Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 7,Skylight,Without Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 8,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.026,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.026,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.039,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2013,ClimateZone 8,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.048,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.039,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.032,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.048,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.039,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.032,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.06,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2013,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, -90.1-2013,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.434,,,, -90.1-2013,ClimateZone 8,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.671,,,, -90.1-2013,ClimateZone 8,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.424,,,, -90.1-2013,ClimateZone 8,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.373,,,, -90.1-2013,ClimateZone 8,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, -90.1-2013,ClimateZone 8,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2013,ClimateZone 8,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 8,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2013,ClimateZone 8,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2013,ClimateZone 8,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2013,ClimateZone 8,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.39 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.39,, -90.1-2013,ClimateZone 8,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.36 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.36,, -90.1-2013,ClimateZone 8,Skylight,Glass with Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.65 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,0.65,, -90.1-2013,ClimateZone 8,Skylight,Plastic with Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,0.27,, -90.1-2013,ClimateZone 8,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,Skylight,Without Curb,Residential,U 0.5 SHGC 0.45 Simple Glazing Skylight,,0,2,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 8,Skylight,Without Curb,Semiheated,U 0.85 SHGC 0.65 Simple Glazing Skylight,,0,2,0.85,TRUE,TRUE,,,0.39,, -90.1-2013,ClimateZone 1,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,1151,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2013,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.93 SHGC 0.25 Simple Glazing Window,,,,0.93,TRUE,TRUE,,,0.25,, -90.1-2013,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2013,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,, -90.1-2013,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2013,ClimateZone 1,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 1,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2013,ClimateZone 1,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 1,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2013,ClimateZone 1,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 1,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2013,ClimateZone 1,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 1,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2013,ClimateZone 1,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2013,ClimateZone 1,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2013,ClimateZone 1,Skylight,Glass with Curb,Nonresidential,U 0.75 SHGC 0.45 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,Skylight,Glass with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.49,, -90.1-2013,ClimateZone 1,Skylight,Glass with Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,0.49,, -90.1-2013,ClimateZone 1,Skylight,Plastic with Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.39,, -90.1-2013,ClimateZone 1,Skylight,Plastic with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,Skylight,Plastic with Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 1,Skylight,Without Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.68,, -90.1-2013,ClimateZone 1,Skylight,Without Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.64,, -90.1-2013,ClimateZone 1,Skylight,Without Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,0.64,, -90.1-2016,ClimateZone 1,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 1,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 1,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 1,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 1,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 1,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.1156,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2016,ClimateZone 1,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 2,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 2,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 2,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 2,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 2,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.096,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2016,ClimateZone 2,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2016,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.37 SHGC 0.25 Simple Glazing Window,,,,0.37,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.54 SHGC 0.25 Simple Glazing Window,,,,0.54,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.83 SHGC 0.25 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 0.37 SHGC 0.25 Simple Glazing Window,,,,0.37,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.54 SHGC 0.25 Simple Glazing Window,,,,0.54,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 0.77 SHGC 0.25 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.93 SHGC 0.45 Simple Glazing Window,,,,0.93,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 0.83 SHGC 0.45 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 2,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 2,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2016,ClimateZone 2,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 2,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2016,ClimateZone 2,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 2,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2016,ClimateZone 2,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 2,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2016,ClimateZone 2,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2016,ClimateZone 2,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2016,ClimateZone 2,Skylight,Glass with Curb,Nonresidential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 2,Skylight,Glass with Curb,Residential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 2,Skylight,Glass with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, -90.1-2016,ClimateZone 2,Skylight,Plastic with Curb,Nonresidential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 2,Skylight,Plastic with Curb,Residential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 2,Skylight,Plastic with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, -90.1-2016,ClimateZone 2,Skylight,Without Curb,Nonresidential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 2,Skylight,Without Curb,Residential,U 0.65 SHGC 0.35 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 2,Skylight,Without Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, -90.1-2016,ClimateZone 3,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 3,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 3,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 3,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 3,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 3,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 3,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 3,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.119,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.096,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2016,ClimateZone 3,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.077,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.072,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2016,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.33 SHGC 0.25 Simple Glazing Window,,,,0.33,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 3,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.25 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Residential,U 0.33 SHGC 0.25 Simple Glazing Window,,,,0.33,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 3,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.25 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.87 SHGC 0.45 Simple Glazing Window,,,,0.87,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 3,GlassDoor,Metal framing (entrance door),Residential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 3,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 3,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2016,ClimateZone 3,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, -90.1-2016,ClimateZone 3,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2016,ClimateZone 3,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 3,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2016,ClimateZone 3,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 3,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2016,ClimateZone 3,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2016,ClimateZone 3,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2016,ClimateZone 3,Skylight,Glass with Curb,Nonresidential,U 0.55 SHGC 0.35 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 3,Skylight,Glass with Curb,Residential,U 0.55 SHGC 0.35 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 3,Skylight,Glass with Curb,Semiheated,U 1.7 SHGC 0.55 Simple Glazing Skylight,,,,1.7,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,Skylight,Plastic with Curb,Nonresidential,U 0.55 SHGC 0.35 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 3,Skylight,Plastic with Curb,Residential,U 0.55 SHGC 0.35 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 3,Skylight,Plastic with Curb,Semiheated,U 1.7 SHGC 0.55 Simple Glazing Skylight,,,,1.7,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 3,Skylight,Without Curb,Nonresidential,U 0.55 SHGC 0.35 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 3,Skylight,Without Curb,Residential,U 0.55 SHGC 0.35 Simple Glazing Skylight,,0,2,0.55,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 3,Skylight,Without Curb,Semiheated,U 1.7 SHGC 0.55 Simple Glazing Skylight,,,,1.7,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 4,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 4,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 4,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 4,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 4,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 4,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 4,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.082,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2016,ClimateZone 4,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.06,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2016,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.31 SHGC 0.36 Simple Glazing Window,,,,0.31,TRUE,TRUE,,,0.36,1.1, -90.1-2016,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.38 SHGC 0.36 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.36,1.1, -90.1-2016,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.31 SHGC 0.36 Simple Glazing Window,,,,0.31,TRUE,TRUE,,,0.36,1.1, -90.1-2016,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.38 SHGC 0.36 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.36,1.1, -90.1-2016,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.36 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.36,1.1, -90.1-2016,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.51 SHGC 0.45 Simple Glazing Window,,,,0.51,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.73 SHGC 0.45 Simple Glazing Window,,,,0.73,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.68 SHGC 0.36 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.36,1.1, -90.1-2016,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2016,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2016,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 0.81 SHGC 0.45 Simple Glazing Window,,,,0.81,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2016,ClimateZone 4,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.843,,,, -90.1-2016,ClimateZone 4,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2016,ClimateZone 4,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2016,ClimateZone 4,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 4,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2016,ClimateZone 4,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 4,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2016,ClimateZone 4,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, -90.1-2016,ClimateZone 4,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2016,ClimateZone 4,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 4,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 4,Skylight,Glass with Curb,Semiheated,U 1.15 SHGC 0.55 Simple Glazing Skylight,,,,1.15,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 4,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 4,Skylight,Plastic with Curb,Semiheated,U 1.15 SHGC 0.55 Simple Glazing Skylight,,,,1.15,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 4,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 4,Skylight,Without Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 4,Skylight,Without Curb,Semiheated,U 1.15 SHGC 0.55 Simple Glazing Skylight,,,,1.15,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 5,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 5,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 5,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 5,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 5,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 5,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 5,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.082,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2016,ClimateZone 5,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.055,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.055,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2016,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.31 SHGC 0.38 Simple Glazing Window,,,,0.31,TRUE,TRUE,,,0.38,1.1, -90.1-2016,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.38 SHGC 0.38 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.38,1.1, -90.1-2016,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.31 SHGC 0.38 Simple Glazing Window,,,,0.31,TRUE,TRUE,,,0.38,1.1, -90.1-2016,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.38 SHGC 0.38 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,0.38,1.1, -90.1-2016,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.38 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.38,1.1, -90.1-2016,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.62 SHGC 0.45 Simple Glazing Window,,,,0.62,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.68 SHGC 0.38 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.38,1.1, -90.1-2016,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2016,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2016,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 0.7 SHGC 0.45 Simple Glazing Window,,,,0.7,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2016,ClimateZone 5,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2016,ClimateZone 5,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.51,,,, -90.1-2016,ClimateZone 5,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2016,ClimateZone 5,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 5,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2016,ClimateZone 5,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 5,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2016,ClimateZone 5,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, -90.1-2016,ClimateZone 5,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2016,ClimateZone 5,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 5,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 5,Skylight,Glass with Curb,Semiheated,U 0.98 SHGC 0.55 Simple Glazing Skylight,,,,0.98,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 5,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 5,Skylight,Plastic with Curb,Semiheated,U 0.98 SHGC 0.55 Simple Glazing Skylight,,,,0.98,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 5,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 5,Skylight,Without Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 5,Skylight,Without Curb,Semiheated,U 0.98 SHGC 0.55 Simple Glazing Skylight,,,,0.98,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 6,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 6,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 6,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 6,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 6,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 6,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 6,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.031,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.06,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2016,ClimateZone 6,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2016,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.3 SHGC 0.4 Simple Glazing Window,,,,0.3,TRUE,TRUE,,,0.4,1.1, -90.1-2016,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.36 SHGC 0.4 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.4,1.1, -90.1-2016,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.68 SHGC 0.4 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.4,1.1, -90.1-2016,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.3 SHGC 0.4 Simple Glazing Window,,,,0.3,TRUE,TRUE,,,0.4,1.1, -90.1-2016,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.36 SHGC 0.4 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.4,1.1, -90.1-2016,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.4 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.4,1.1, -90.1-2016,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.45 SHGC 0.45 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.51 SHGC 0.45 Simple Glazing Window,,,,0.51,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2016,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2016,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 0.59 SHGC 0.45 Simple Glazing Window,,,,0.59,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.51,,,, -90.1-2016,ClimateZone 6,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2016,ClimateZone 6,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.434,,,, -90.1-2016,ClimateZone 6,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.671,,,, -90.1-2016,ClimateZone 6,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 6,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2016,ClimateZone 6,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 6,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, -90.1-2016,ClimateZone 6,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2016,ClimateZone 6,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2016,ClimateZone 6,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 6,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 6,Skylight,Glass with Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 6,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 6,Skylight,Plastic with Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 6,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 6,Skylight,Without Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2016,ClimateZone 6,Skylight,Without Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 7,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 7,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 7,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 7,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 7,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 7,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.042,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.042,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.27,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 7,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.039,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2016,ClimateZone 7,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.044,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.044,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.042,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.072,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2016,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.28 SHGC 0.45 Simple Glazing Window,,,,0.28,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.33 SHGC 0.45 Simple Glazing Window,,,,0.33,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.28 SHGC 0.45 Simple Glazing Window,,,,0.28,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.33 SHGC 0.45 Simple Glazing Window,,,,0.33,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.51,,,, -90.1-2016,ClimateZone 7,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.671,,,, -90.1-2016,ClimateZone 7,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.434,,,, -90.1-2016,ClimateZone 7,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.671,,,, -90.1-2016,ClimateZone 7,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 7,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2016,ClimateZone 7,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 7,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2016,ClimateZone 7,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2016,ClimateZone 7,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2016,ClimateZone 7,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.55 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.55 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,Skylight,Glass with Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.55 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.55 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,Skylight,Plastic with Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.55 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,Skylight,Without Curb,Residential,U 0.5 SHGC 0.55 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 7,Skylight,Without Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 8,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 8,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 8,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 8,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 8,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 8,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 8,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.026,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.026,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.039,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2016,ClimateZone 8,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.048,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.039,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.048,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.039,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.06,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2016,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.25 SHGC 0.45 Simple Glazing Window,,,,0.25,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.29 SHGC 0.45 Simple Glazing Window,,,,0.29,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.25 SHGC 0.45 Simple Glazing Window,,,,0.25,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.29 SHGC 0.45 Simple Glazing Window,,,,0.29,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.32 SHGC 0.45 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.38 SHGC 0.45 Simple Glazing Window,,,,0.38,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, -90.1-2016,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.434,,,, -90.1-2016,ClimateZone 8,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.671,,,, -90.1-2016,ClimateZone 8,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.424,,,, -90.1-2016,ClimateZone 8,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.373,,,, -90.1-2016,ClimateZone 8,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, -90.1-2016,ClimateZone 8,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2016,ClimateZone 8,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 8,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2016,ClimateZone 8,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2016,ClimateZone 8,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2016,ClimateZone 8,Skylight,Glass with Curb,Nonresidential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,Skylight,Glass with Curb,Residential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,Skylight,Glass with Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,Skylight,Plastic with Curb,Nonresidential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,Skylight,Plastic with Curb,Residential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,Skylight,Plastic with Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,Skylight,Without Curb,Nonresidential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,Skylight,Without Curb,Residential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 8,Skylight,Without Curb,Semiheated,U 0.85 SHGC 0.55 Simple Glazing Skylight,,,,0.85,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,1151,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2016,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.93 SHGC 0.45 Simple Glazing Window,,,,0.93,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.1 SHGC 0.45 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2016,ClimateZone 1,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 1,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2016,ClimateZone 1,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 1,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2016,ClimateZone 1,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 1,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2016,ClimateZone 1,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 1,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2016,ClimateZone 1,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2016,ClimateZone 1,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2016,ClimateZone 1,Skylight,Glass with Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 1,Skylight,Glass with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 1,Skylight,Glass with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, -90.1-2016,ClimateZone 1,Skylight,Plastic with Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 1,Skylight,Plastic with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 1,Skylight,Plastic with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, -90.1-2016,ClimateZone 1,Skylight,Without Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 1,Skylight,Without Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 1,Skylight,Without Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, -90.1-2019,ClimateZone 1,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 1,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 1,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 1,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 1,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 1,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.1156,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2019,ClimateZone 1,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 2,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 2,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 2,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 2,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.069,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.066,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 2,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.173,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.096,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2019,ClimateZone 2,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2019,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1,Fixed -90.1-2019,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1,Fixed -90.1-2019,ClimateZone 2,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.77 SHGC 0.23 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.23,1.1,Entrance door -90.1-2019,ClimateZone 2,ExteriorWindow,Fixed,Nonresidential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1, -90.1-2019,ClimateZone 2,ExteriorWindow,Operable,Nonresidential,U 0.6 SHGC 0.23 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.23,1.1, -90.1-2019,ClimateZone 2,ExteriorWindow,Entrance door,Nonresidential,U 0.77 SHGC 0.23 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.23,1.1, -90.1-2019,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Residential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1,Fixed -90.1-2019,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1,Fixed -90.1-2019,ClimateZone 2,ExteriorWindow,Metal framing (all other),Residential,U 0.77 SHGC 0.23 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.23,1.1,Entrance door -90.1-2019,ClimateZone 2,ExteriorWindow,Fixed,Residential,U 0.45 SHGC 0.25 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.25,1.1, -90.1-2019,ClimateZone 2,ExteriorWindow,Operable,Residential,U 0.6 SHGC 0.23 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.23,1.1, -90.1-2019,ClimateZone 2,ExteriorWindow,Entrance door,Residential,U 0.77 SHGC 0.23 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,0.23,1.1, -90.1-2019,ClimateZone 2,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 2,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 2,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,,Entrance door -90.1-2019,ClimateZone 2,ExteriorWindow,Fixed,Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorWindow,Operable,Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,ExteriorWindow,Entrance door,Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2019,ClimateZone 2,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2019,ClimateZone 2,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 2,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 2,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2019,ClimateZone 2,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 2,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2019,ClimateZone 2,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 2,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2019,ClimateZone 2,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 2,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2019,ClimateZone 2,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2019,ClimateZone 2,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2019,ClimateZone 2,Skylight,Glass with Curb,Nonresidential,U 0.65 SHGC 0.3 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 2,Skylight,Glass with Curb,Residential,U 0.65 SHGC 0.3 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 2,Skylight,Glass with Curb,Semiheated,U 0.9 SHGC 0.55 Simple Glazing Skylight,,,,0.9,TRUE,TRUE,,,0.55,, -90.1-2019,ClimateZone 2,Skylight,Plastic with Curb,Nonresidential,U 0.65 SHGC 0.3 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 2,Skylight,Plastic with Curb,Residential,U 0.65 SHGC 0.3 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 2,Skylight,Plastic with Curb,Semiheated,U 0.9 SHGC 0.55 Simple Glazing Skylight,,,,0.9,TRUE,TRUE,,,0.55,, -90.1-2019,ClimateZone 2,Skylight,Without Curb,Nonresidential,U 0.65 SHGC 0.3 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 2,Skylight,Without Curb,Residential,U 0.65 SHGC 0.3 Simple Glazing Skylight,,,,0.65,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 2,Skylight,Without Curb,Semiheated,U 0.9 SHGC 0.55 Simple Glazing Skylight,,,,0.9,TRUE,TRUE,,,0.55,, -90.1-2019,ClimateZone 3,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 3,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 3,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 3,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 3,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 3,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 3,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.137,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 3,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.041,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.119,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.096,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.053,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2019,ClimateZone 3,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.077,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.072,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2019,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.42 SHGC 0.25 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.25,1.1,Fixed -90.1-2019,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.42 SHGC 0.25 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.25,1.1,Fixed -90.1-2019,ClimateZone 3,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.68 SHGC 0.23 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.23,1.1,Entrance door -90.1-2019,ClimateZone 3,ExteriorWindow,Fixed,Nonresidential,U 0.42 SHGC 0.25 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.25,1.1, -90.1-2019,ClimateZone 3,ExteriorWindow,Operable,Nonresidential,U 0.54 SHGC 0.23 Simple Glazing Window,,,,0.54,TRUE,TRUE,,,0.23,1.1, -90.1-2019,ClimateZone 3,ExteriorWindow,Entrance door,Nonresidential,U 0.68 SHGC 0.23 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.23,1.1, -90.1-2019,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Residential,U 0.42 SHGC 0.25 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.25,1.1,Fixed -90.1-2019,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.42 SHGC 0.25 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.25,1.1,Fixed -90.1-2019,ClimateZone 3,ExteriorWindow,Metal framing (all other),Residential,U 0.68 SHGC 0.23 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.23,1.1,Entrance door -90.1-2019,ClimateZone 3,ExteriorWindow,Fixed,Residential,U 0.42 SHGC 0.25 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.25,1.1, -90.1-2019,ClimateZone 3,ExteriorWindow,Operable,Residential,U 0.54 SHGC 0.23 Simple Glazing Window,,,,0.54,TRUE,TRUE,,,0.23,1.1, -90.1-2019,ClimateZone 3,ExteriorWindow,Entrance door,Residential,U 0.68 SHGC 0.23 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,0.23,1.1, -90.1-2019,ClimateZone 3,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 3,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 3,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,,Entrance door -90.1-2019,ClimateZone 3,ExteriorWindow,Fixed,Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorWindow,Operable,Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,ExteriorWindow,Entrance door,Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,1.1, -90.1-2019,ClimateZone 3,GlassDoor,Metal framing (entrance door),Residential,U 0.6 SHGC 0.25 Simple Glazing Window,,,,0.6,TRUE,TRUE,,,0.25,1.1, -90.1-2019,ClimateZone 3,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 3,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2019,ClimateZone 3,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, -90.1-2019,ClimateZone 3,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2019,ClimateZone 3,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 3,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2019,ClimateZone 3,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 3,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2019,ClimateZone 3,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2019,ClimateZone 3,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2019,ClimateZone 3,Skylight,Glass with Curb,Nonresidential,U 0.55 SHGC 0.3 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 3,Skylight,Glass with Curb,Residential,U 0.55 SHGC 0.3 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 3,Skylight,Glass with Curb,Semiheated,U 0.9 SHGC 0.55 Simple Glazing Skylight,,,,0.9,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,Skylight,Plastic with Curb,Nonresidential,U 0.55 SHGC 0.3 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 3,Skylight,Plastic with Curb,Residential,U 0.55 SHGC 0.3 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 3,Skylight,Plastic with Curb,Semiheated,U 0.9 SHGC 0.55 Simple Glazing Skylight,,,,0.9,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 3,Skylight,Without Curb,Nonresidential,U 0.55 SHGC 0.3 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 3,Skylight,Without Curb,Residential,U 0.55 SHGC 0.3 Simple Glazing Skylight,,,,0.55,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 3,Skylight,Without Curb,Semiheated,U 0.9 SHGC 0.55 Simple Glazing Skylight,,,,0.9,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 4,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 4,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 4,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 4,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 4,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 4,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 4,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.093,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.082,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2019,ClimateZone 4,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.06,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.162,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2019,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1,Fixed -90.1-2019,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1,Fixed -90.1-2019,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Residential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1,Fixed -90.1-2019,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1,Fixed -90.1-2019,ClimateZone 4,ExteriorWindow,Metal framing (all other),Residential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1,Entrance door -90.1-2019,ClimateZone 4,ExteriorWindow,Fixed,Residential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1, -90.1-2019,ClimateZone 4,ExteriorWindow,Operable,Residential,U 0.45 SHGC 0.33 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.33,1.1, -90.1-2019,ClimateZone 4,ExteriorWindow,Entrance door,Residential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1, -90.1-2019,ClimateZone 4,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 4,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 4,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,,Entrance door -90.1-2019,ClimateZone 4,ExteriorWindow,Fixed,Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWindow,Operable,Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWindow,Entrance door,Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1,Entrance door -90.1-2019,ClimateZone 4,ExteriorWindow,Fixed,Nonresidential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1, -90.1-2019,ClimateZone 4,ExteriorWindow,Operable,Nonresidential,U 0.45 SHGC 0.33 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.33,1.1, -90.1-2019,ClimateZone 4,ExteriorWindow,Entrance door,Nonresidential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1, -90.1-2019,ClimateZone 4,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2019,ClimateZone 4,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2019,ClimateZone 4,GlassDoor,Metal framing (entrance door),Semiheated,U 0.81 SHGC 0.45 Simple Glazing Window,,,,0.81,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2019,ClimateZone 4,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.843,,,, -90.1-2019,ClimateZone 4,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2019,ClimateZone 4,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2019,ClimateZone 4,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 4,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2019,ClimateZone 4,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 4,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2019,ClimateZone 4,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, -90.1-2019,ClimateZone 4,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2019,ClimateZone 4,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 4,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 4,Skylight,Glass with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 4,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 4,Skylight,Plastic with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 4,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 4,Skylight,Without Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 4,Skylight,Without Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 5,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 5,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 5,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 5,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 5,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 5,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.057,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.107,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 5,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.082,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2019,ClimateZone 5,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.09,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.055,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.055,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2019,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.36 SHGC 0.38 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.38,1.1,Fixed -90.1-2019,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.36 SHGC 0.38 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.38,1.1,Fixed -90.1-2019,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Residential,U 0.36 SHGC 0.38 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.38,1.1,Fixed -90.1-2019,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.36 SHGC 0.38 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.38,1.1,Fixed -90.1-2019,ClimateZone 5,ExteriorWindow,Metal framing (all other),Residential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1,Entrance door -90.1-2019,ClimateZone 5,ExteriorWindow,Fixed,Residential,U 0.36 SHGC 0.38 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.38,1.1, -90.1-2019,ClimateZone 5,ExteriorWindow,Operable,Residential,U 0.45 SHGC 0.33 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.33,1.1, -90.1-2019,ClimateZone 5,ExteriorWindow,Entrance door,Residential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1, -90.1-2019,ClimateZone 5,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 5,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 5,ExteriorWindow,Metal framing (all other),Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,,Entrance door -90.1-2019,ClimateZone 5,ExteriorWindow,Fixed,Semiheated,U 0.5 SHGC 0.45 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWindow,Operable,Semiheated,U 0.65 SHGC 0.45 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWindow,Entrance door,Semiheated,U 0.77 SHGC 0.45 Simple Glazing Window,,,,0.77,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1,Entrance door -90.1-2019,ClimateZone 5,ExteriorWindow,Fixed,Nonresidential,U 0.36 SHGC 0.38 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.38,1.1, -90.1-2019,ClimateZone 5,ExteriorWindow,Operable,Nonresidential,U 0.45 SHGC 0.33 Simple Glazing Window,,,,0.45,TRUE,TRUE,,,0.33,1.1, -90.1-2019,ClimateZone 5,ExteriorWindow,Entrance door,Nonresidential,U 0.63 SHGC 0.33 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.33,1.1, -90.1-2019,ClimateZone 5,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2019,ClimateZone 5,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2019,ClimateZone 5,GlassDoor,Metal framing (entrance door),Semiheated,U 0.7 SHGC 0.45 Simple Glazing Window,,,,0.7,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.52,,,, -90.1-2019,ClimateZone 5,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2019,ClimateZone 5,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.51,,,, -90.1-2019,ClimateZone 5,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2019,ClimateZone 5,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 5,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.9,,,, -90.1-2019,ClimateZone 5,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 5,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2019,ClimateZone 5,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, -90.1-2019,ClimateZone 5,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2019,ClimateZone 5,Skylight,Glass with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 5,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 5,Skylight,Glass with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,Skylight,Plastic with Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 5,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 5,Skylight,Plastic with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 5,Skylight,Without Curb,Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 5,Skylight,Without Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 5,Skylight,Without Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 6,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 6,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 6,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 6,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 6,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.36,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 6,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.087,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 6,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.031,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.021,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.06,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2019,ClimateZone 6,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.08,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.05,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.084,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2019,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.34 SHGC 0.38 Simple Glazing Window,,,,0.34,TRUE,TRUE,,,0.38,1.1,Fixed -90.1-2019,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.34 SHGC 0.38 Simple Glazing Window,,,,0.34,TRUE,TRUE,,,0.38,1.1,Fixed -90.1-2019,ClimateZone 6,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.63 SHGC 0.34 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.34,1.1,Entrance door -90.1-2019,ClimateZone 6,ExteriorWindow,Fixed,Nonresidential,U 0.34 SHGC 0.38 Simple Glazing Window,,,,0.34,TRUE,TRUE,,,0.38,1.1, -90.1-2019,ClimateZone 6,ExteriorWindow,Operable,Nonresidential,U 0.42 SHGC 0.34 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.34,1.1, -90.1-2019,ClimateZone 6,ExteriorWindow,Entrance door,Nonresidential,U 0.63 SHGC 0.34 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.34,1.1, -90.1-2019,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Residential,U 0.34 SHGC 0.38 Simple Glazing Window,,,,0.34,TRUE,TRUE,,,0.38,1.1,Fixed -90.1-2019,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.34 SHGC 0.38 Simple Glazing Window,,,,0.34,TRUE,TRUE,,,0.38,1.1,Fixed -90.1-2019,ClimateZone 6,ExteriorWindow,Metal framing (all other),Residential,U 0.63 SHGC 0.34 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.34,1.1,Entrance door -90.1-2019,ClimateZone 6,ExteriorWindow,Fixed,Residential,U 0.34 SHGC 0.38 Simple Glazing Window,,,,0.34,TRUE,TRUE,,,0.38,1.1, -90.1-2019,ClimateZone 6,ExteriorWindow,Operable,Residential,U 0.42 SHGC 0.34 Simple Glazing Window,,,,0.42,TRUE,TRUE,,,0.34,1.1, -90.1-2019,ClimateZone 6,ExteriorWindow,Entrance door,Residential,U 0.63 SHGC 0.34 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.34,1.1, -90.1-2019,ClimateZone 6,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.39 SHGC 0.45 Simple Glazing Window,,,,0.39,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 6,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.39 SHGC 0.45 Simple Glazing Window,,,,0.39,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 6,ExteriorWindow,Metal framing (all other),Semiheated,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,,,Entrance door -90.1-2019,ClimateZone 6,ExteriorWindow,Fixed,Semiheated,U 0.39 SHGC 0.45 Simple Glazing Window,,,,0.39,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorWindow,Operable,Semiheated,U 0.48 SHGC 0.45 Simple Glazing Window,,,,0.48,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,ExteriorWindow,Entrance door,Semiheated,U 0.68 SHGC 0.45 Simple Glazing Window,,,,0.68,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2019,ClimateZone 6,GlassDoor,Metal framing (entrance door),Residential,U 0.5 SHGC 0.4 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.4,1.1, -90.1-2019,ClimateZone 6,GlassDoor,Metal framing (entrance door),Semiheated,U 0.59 SHGC 0.45 Simple Glazing Window,,,,0.59,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.51,,,, -90.1-2019,ClimateZone 6,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.688,,,, -90.1-2019,ClimateZone 6,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.434,,,, -90.1-2019,ClimateZone 6,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.671,,,, -90.1-2019,ClimateZone 6,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 6,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2019,ClimateZone 6,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 6,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.092,,, -90.1-2019,ClimateZone 6,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2019,ClimateZone 6,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2019,ClimateZone 6,Skylight,Glass with Curb,Nonresidential,U 0.47 SHGC 0.4 Simple Glazing Skylight,,,,0.47,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 6,Skylight,Glass with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 6,Skylight,Glass with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,Skylight,Plastic with Curb,Nonresidential,U 0.47 SHGC 0.4 Simple Glazing Skylight,,,,0.47,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 6,Skylight,Plastic with Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 6,Skylight,Plastic with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 6,Skylight,Without Curb,Nonresidential,U 0.47 SHGC 0.4 Simple Glazing Skylight,,,,0.47,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 6,Skylight,Without Curb,Residential,U 0.5 SHGC 0.4 Simple Glazing Skylight,,,,0.5,TRUE,TRUE,,,0.4,, -90.1-2019,ClimateZone 6,Skylight,Without Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 7,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 7,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 7,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 7,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 7,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 7,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.042,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.042,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.27,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.074,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 7,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.029,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.039,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2019,ClimateZone 7,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.044,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.049,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.071,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.044,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.042,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.123,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.072,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2019,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.29 SHGC 0.4 Simple Glazing Window,,,,0.29,TRUE,TRUE,,,0.4,1.1,Fixed -90.1-2019,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.29 SHGC 0.4 Simple Glazing Window,,,,0.29,TRUE,TRUE,,,0.4,1.1,Fixed -90.1-2019,ClimateZone 7,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1,Entrance door -90.1-2019,ClimateZone 7,ExteriorWindow,Fixed,Nonresidential,U 0.29 SHGC 0.4 Simple Glazing Window,,,,0.29,TRUE,TRUE,,,0.4,1.1, -90.1-2019,ClimateZone 7,ExteriorWindow,Operable,Nonresidential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1, -90.1-2019,ClimateZone 7,ExteriorWindow,Entrance door,Nonresidential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1, -90.1-2019,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Residential,U 0.29 SHGC 0.4 Simple Glazing Window,,,,0.29,TRUE,TRUE,,,0.4,1.1,Fixed -90.1-2019,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.29 SHGC 0.4 Simple Glazing Window,,,,0.29,TRUE,TRUE,,,0.4,1.1,Fixed -90.1-2019,ClimateZone 7,ExteriorWindow,Metal framing (all other),Residential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1,Entrance door -90.1-2019,ClimateZone 7,ExteriorWindow,Fixed,Residential,U 0.26 SHGC 0.4 Simple Glazing Window,,,,0.26,TRUE,TRUE,,,0.4,1.1, -90.1-2019,ClimateZone 7,ExteriorWindow,Operable,Residential,U 0.36 SHGC 0.36 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,0.36,1.1, -90.1-2019,ClimateZone 7,ExteriorWindow,Entrance door,Residential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1, -90.1-2019,ClimateZone 7,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.36 SHGC 0.45 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 7,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.36 SHGC 0.45 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 7,ExteriorWindow,Metal framing (all other),Semiheated,U 0.63 SHGC 0.45 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,,,Entrance door -90.1-2019,ClimateZone 7,ExteriorWindow,Fixed,Semiheated,U 0.36 SHGC 0.45 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorWindow,Operable,Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,ExteriorWindow,Entrance door,Semiheated,U 0.63 SHGC 0.45 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, -90.1-2019,ClimateZone 7,GlassDoor,Metal framing (entrance door),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, -90.1-2019,ClimateZone 7,GlassDoor,Metal framing (entrance door),Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.51,,,, -90.1-2019,ClimateZone 7,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.671,,,, -90.1-2019,ClimateZone 7,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.434,,,, -90.1-2019,ClimateZone 7,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.671,,,, -90.1-2019,ClimateZone 7,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 7,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2019,ClimateZone 7,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 7,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2019,ClimateZone 7,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2019,ClimateZone 7,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2019,ClimateZone 7,Skylight,Glass with Curb,Nonresidential,U 0.44 SHGC 0.55 Simple Glazing Skylight,,,,0.44,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,Skylight,Glass with Curb,Residential,U 0.44 SHGC 0.55 Simple Glazing Skylight,,,,0.44,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,Skylight,Glass with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,Skylight,Plastic with Curb,Nonresidential,U 0.44 SHGC 0.55 Simple Glazing Skylight,,,,0.44,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,Skylight,Plastic with Curb,Residential,U 0.44 SHGC 0.55 Simple Glazing Skylight,,,,0.44,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,Skylight,Plastic with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,Skylight,Without Curb,Nonresidential,U 0.44 SHGC 0.55 Simple Glazing Skylight,,,,0.44,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,Skylight,Without Curb,Residential,U 0.44 SHGC 0.55 Simple Glazing Skylight,,,,0.44,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 7,Skylight,Without Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 8,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 8,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 8,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 8,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 8,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 8,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.038,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.064,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.052,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 8,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.026,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.028,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.026,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.017,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.039,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.037,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2019,ClimateZone 8,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.048,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.039,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.048,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.039,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.037,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.104,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.06,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.064,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.051,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2019,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.26 SHGC 0.4 Simple Glazing Window,,,,0.26,TRUE,TRUE,,,0.4,1.1,Fixed -90.1-2019,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.26 SHGC 0.4 Simple Glazing Window,,,,0.26,TRUE,TRUE,,,0.4,1.1,Fixed -90.1-2019,ClimateZone 8,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1,Entrance door -90.1-2019,ClimateZone 8,ExteriorWindow,Fixed,Nonresidential,U 0.26 SHGC 0.4 Simple Glazing Window,,,,0.26,TRUE,TRUE,,,0.4,1.1, -90.1-2019,ClimateZone 8,ExteriorWindow,Operable,Nonresidential,U 0.32 SHGC 0.36 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.36,1.1, -90.1-2019,ClimateZone 8,ExteriorWindow,Entrance door,Nonresidential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1, -90.1-2019,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Residential,U 0.26 SHGC 0.4 Simple Glazing Window,,,,0.26,TRUE,TRUE,,,0.4,1.1,Fixed -90.1-2019,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.26 SHGC 0.4 Simple Glazing Window,,,,0.26,TRUE,TRUE,,,0.4,1.1,Fixed -90.1-2019,ClimateZone 8,ExteriorWindow,Metal framing (all other),Residential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1,Entrance door -90.1-2019,ClimateZone 8,ExteriorWindow,Fixed,Residential,U 0.26 SHGC 0.4 Simple Glazing Window,,,,0.26,TRUE,TRUE,,,0.4,1.1, -90.1-2019,ClimateZone 8,ExteriorWindow,Operable,Residential,U 0.32 SHGC 0.36 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.36,1.1, -90.1-2019,ClimateZone 8,ExteriorWindow,Entrance door,Residential,U 0.63 SHGC 0.36 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,0.36,1.1, -90.1-2019,ClimateZone 8,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.36 SHGC 0.45 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 8,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.36 SHGC 0.45 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 8,ExteriorWindow,Metal framing (all other),Semiheated,U 0.63 SHGC 0.45 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,,,Entrance door -90.1-2019,ClimateZone 8,ExteriorWindow,Fixed,Semiheated,U 0.36 SHGC 0.45 Simple Glazing Window,,,,0.36,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorWindow,Operable,Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,ExteriorWindow,Metal framing (entrance door),Semiheated,U 0.63 SHGC 0.45 Simple Glazing Window,,,,0.63,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, -90.1-2019,ClimateZone 8,GlassDoor,Metal framing (entrance door),Residential,U 0.4 SHGC 0.45 Simple Glazing Window,,,,0.4,TRUE,TRUE,,,0.45,1.1, -90.1-2019,ClimateZone 8,GlassDoor,Metal framing (entrance door),Semiheated,U 0.44 SHGC 0.45 Simple Glazing Window,,,,0.44,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.434,,,, -90.1-2019,ClimateZone 8,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.671,,,, -90.1-2019,ClimateZone 8,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.424,,,, -90.1-2019,ClimateZone 8,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.373,,,, -90.1-2019,ClimateZone 8,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.54,,,, -90.1-2019,ClimateZone 8,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.86,,,, -90.1-2019,ClimateZone 8,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 8,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2019,ClimateZone 8,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.063,,, -90.1-2019,ClimateZone 8,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,0.119,,, -90.1-2019,ClimateZone 8,Skylight,Glass with Curb,Nonresidential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,Skylight,Glass with Curb,Residential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,Skylight,Glass with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,Skylight,Plastic with Curb,Nonresidential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,Skylight,Plastic with Curb,Residential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,Skylight,Plastic with Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,Skylight,Without Curb,Nonresidential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,Skylight,Without Curb,Residential,U 0.41 SHGC 0.55 Simple Glazing Skylight,,,,0.41,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 8,Skylight,Without Curb,Semiheated,U 0.75 SHGC 0.55 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,1151,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2019,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.5 SHGC 0.23 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.23,1.1,Fixed -90.1-2019,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.5 SHGC 0.23 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.23,1.1,Fixed -90.1-2019,ClimateZone 1,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.83 SHGC 0.21 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.21,1.1,Entrance door -90.1-2019,ClimateZone 1,ExteriorWindow,Fixed,Nonresidential,U 0.5 SHGC 0.23 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.23,1.1, -90.1-2019,ClimateZone 1,ExteriorWindow,Operable,Nonresidential,U 0.62 SHGC 0.21 Simple Glazing Window,,,,0.62,TRUE,TRUE,,,0.21,1.1, -90.1-2019,ClimateZone 1,ExteriorWindow,Entrance door,Nonresidential,U 0.83 SHGC 0.21 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.21,1.1, -90.1-2019,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Residential,U 0.5 SHGC 0.23 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.23,1.1,Fixed -90.1-2019,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.5 SHGC 0.23 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.23,1.1,Fixed -90.1-2019,ClimateZone 1,ExteriorWindow,Metal framing (all other),Residential,U 0.83 SHGC 0.21 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.21,1.1,Entrance door -90.1-2019,ClimateZone 1,ExteriorWindow,Fixed,Residential,U 0.5 SHGC 0.23 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.23,1.1, -90.1-2019,ClimateZone 1,ExteriorWindow,Operable,Residential,U 0.62 SHGC 0.21 Simple Glazing Window,,,,0.62,TRUE,TRUE,,,0.21,1.1, -90.1-2019,ClimateZone 1,ExteriorWindow,Entrance door,Residential,U 0.83 SHGC 0.21 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.21,1.1, -90.1-2019,ClimateZone 1,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 1,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 1,ExteriorWindow,Metal framing (all other),Semiheated,U 1.1 SHGC 0.45 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,,,Entrance door -90.1-2019,ClimateZone 1,ExteriorWindow,Fixed,Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorWindow,Operable,Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,ExteriorWindow,Entrance door,Semiheated,U 1.1 SHGC 0.45 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 1,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2019,ClimateZone 1,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2019,ClimateZone 1,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2019,ClimateZone 1,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 1,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2019,ClimateZone 1,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 1,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2019,ClimateZone 1,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 1,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2019,ClimateZone 1,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 1,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2019,ClimateZone 1,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2019,ClimateZone 1,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2019,ClimateZone 1,Skylight,Glass with Curb,Nonresidential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 1,Skylight,Glass with Curb,Residential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 1,Skylight,Glass with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, -90.1-2019,ClimateZone 1,Skylight,Plastic with Curb,Nonresidential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 1,Skylight,Plastic with Curb,Residential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 1,Skylight,Plastic with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, -90.1-2019,ClimateZone 1,Skylight,Without Curb,Nonresidential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 1,Skylight,Without Curb,Residential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 1,Skylight,Without Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, -90.1-2016,ClimateZone 0,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 0,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 0,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 0,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2016,ClimateZone 0,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 0,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.032,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.115,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2016,ClimateZone 0,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2016,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.32 SHGC 0.22 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.22,1.1, -90.1-2016,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1, -90.1-2016,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.83 SHGC 0.22 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.22,1.1, -90.1-2016,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 0.32 SHGC 0.22 Simple Glazing Window,,,,0.32,TRUE,TRUE,,,0.22,1.1, -90.1-2016,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1, -90.1-2016,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 0.83 SHGC 0.22 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.22,1.1, -90.1-2016,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.93 SHGC 0.45 Simple Glazing Window,,,,0.93,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.1 SHGC 0.45 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,,, -90.1-2016,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2016,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2016,ClimateZone 0,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 0,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2016,ClimateZone 0,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 0,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2016,ClimateZone 0,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2016,ClimateZone 0,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2016,ClimateZone 0,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2016,ClimateZone 0,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2016,ClimateZone 0,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2016,ClimateZone 0,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2016,ClimateZone 0,Skylight,Glass with Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 0,Skylight,Glass with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 0,Skylight,Glass with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, -90.1-2016,ClimateZone 0,Skylight,Plastic with Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 0,Skylight,Plastic with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 0,Skylight,Plastic with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, -90.1-2016,ClimateZone 0,Skylight,Without Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 0,Skylight,Without Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,0.75,TRUE,TRUE,,,0.35,, -90.1-2016,ClimateZone 0,Skylight,Without Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,0.55,, -90.1-2019,ClimateZone 0,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 0,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 0,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.37,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 0,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.31,TRUE,TRUE,,,,,Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table -90.1-2019,ClimateZone 0,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 0,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.032,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.115,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2019,ClimateZone 0,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2019,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1,Fixed -90.1-2019,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1,Fixed -90.1-2019,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 0.83 SHGC 0.2 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.2,1.1,Entrance door -90.1-2019,ClimateZone 0,ExteriorWindow,Fixed,Nonresidential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1, -90.1-2019,ClimateZone 0,ExteriorWindow,Operable,Nonresidential,U 0.62 SHGC 0.2 Simple Glazing Window,,,,0.62,TRUE,TRUE,,,0.2,1.1, -90.1-2019,ClimateZone 0,ExteriorWindow,Entrance door,Nonresidential,U 0.83 SHGC 0.2 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.2,1.1, -90.1-2019,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1,Fixed -90.1-2019,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1,Fixed -90.1-2019,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 0.83 SHGC 0.2 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.2,1.1,Entrance door -90.1-2019,ClimateZone 0,ExteriorWindow,Fixed,Residential,U 0.5 SHGC 0.22 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.22,1.1, -90.1-2019,ClimateZone 0,ExteriorWindow,Operable,Residential,U 0.62 SHGC 0.2 Simple Glazing Window,,,,0.62,TRUE,TRUE,,,0.2,1.1, -90.1-2019,ClimateZone 0,ExteriorWindow,Entrance door,Residential,U 0.83 SHGC 0.2 Simple Glazing Window,,,,0.83,TRUE,TRUE,,,0.2,1.1, -90.1-2019,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,,Fixed -90.1-2019,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.1 SHGC 0.45 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,,,Entrance door -90.1-2019,ClimateZone 0,ExteriorWindow,Fixed,Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorWindow,Operable,Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,ExteriorWindow,Entrance door,Semiheated,U 1.1 SHGC 0.45 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2019,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2019,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2019,ClimateZone 0,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 0,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2019,ClimateZone 0,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 0,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2019,ClimateZone 0,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2019,ClimateZone 0,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2019,ClimateZone 0,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2019,ClimateZone 0,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2019,ClimateZone 0,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2019,ClimateZone 0,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2019,ClimateZone 0,Skylight,Glass with Curb,Nonresidential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 0,Skylight,Glass with Curb,Residential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 0,Skylight,Glass with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,Skylight,Plastic with Curb,Nonresidential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 0,Skylight,Plastic with Curb,Residential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 0,Skylight,Plastic with Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,,, -90.1-2019,ClimateZone 0,Skylight,Without Curb,Nonresidential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 0,Skylight,Without Curb,Residential,U 0.7 SHGC 0.3 Simple Glazing Skylight,,,,0.7,TRUE,TRUE,,,0.3,, -90.1-2019,ClimateZone 0,Skylight,Without Curb,Semiheated,U 1.8 SHGC 0.55 Simple Glazing Skylight,,,,1.8,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 0,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorRoof,IEAD,Residential,Typical IEAD Roof,,,,0.063,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,1.282,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.614,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof,,,,0.065,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,1.28,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2004,ClimateZone 0,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,1.18,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.25 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,0.25,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 1.22 SHGC 0.19 Simple Glazing Window,,40.001,100,1.22,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,1,10,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,10.001,20,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,20.001,30,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.22 SHGC 0.45 Simple Glazing Window,,30.001,40,1.22,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 0.98 SHGC 0.45 Simple Glazing Window,,40.001,100,0.98,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 0,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 0,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 0,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 0,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2004,ClimateZone 0,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2004,ClimateZone 0,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2004,ClimateZone 0,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 0,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 0,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2004,ClimateZone 0,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.36 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.36,, -90.1-2004,ClimateZone 0,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.19,, -90.1-2004,ClimateZone 0,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.16 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.16,, -90.1-2004,ClimateZone 0,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.34 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2004,ClimateZone 0,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.34,, -90.1-2004,ClimateZone 0,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.27,, -90.1-2004,ClimateZone 0,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.27,, -90.1-2004,ClimateZone 0,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 0,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.065,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.063,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.65,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,1.28,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2007,ClimateZone 0,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,1.18,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2007,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2007,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.45 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 0,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2007,ClimateZone 0,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 0,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2007,ClimateZone 0,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2007,ClimateZone 0,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2007,ClimateZone 0,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2007,ClimateZone 0,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 0,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 0,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2007,ClimateZone 0,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.49 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.49,, -90.1-2007,ClimateZone 0,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.49,, -90.1-2007,ClimateZone 0,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.39 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.39,, -90.1-2007,ClimateZone 0,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.34 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,,, -90.1-2007,ClimateZone 0,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.77,, -90.1-2007,ClimateZone 0,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.77,, -90.1-2007,ClimateZone 0,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.62,, -90.1-2007,ClimateZone 0,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorDoor,Swinging,Semiheated,Typical Uninsulated Swinging Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.033,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 0,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.065,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.063,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.034,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.065,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.167,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2010,ClimateZone 0,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.093,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.093,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.113,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2010,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2010,ClimateZone 0,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 0,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2010,ClimateZone 0,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 0,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2010,ClimateZone 0,GroundContactFloor,Unheated,Semiheated,ext-slab,,,,,TRUE,TRUE,0.73,,,, -90.1-2010,ClimateZone 0,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2010,ClimateZone 0,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2010,ClimateZone 0,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 0,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 0,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2010,ClimateZone 0,Skylight,Glass with Curb,Nonresidential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,0.19,, -90.1-2010,ClimateZone 0,Skylight,Glass with Curb,Residential,U 1.98 SHGC 0.19 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,Skylight,Glass with Curb,Semiheated,U 1.98 SHGC 0.45 Simple Glazing Skylight,,0,2,1.98,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,Skylight,Plastic with Curb,Nonresidential,U 1.90 SHGC 0.34 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.36,, -90.1-2010,ClimateZone 0,Skylight,Plastic with Curb,Residential,U 1.90 SHGC 0.27 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, -90.1-2010,ClimateZone 0,Skylight,Plastic with Curb,Semiheated,U 1.90 SHGC 0.39 Simple Glazing Skylight,,0,2,1.9,TRUE,TRUE,,,0.19,, -90.1-2010,ClimateZone 0,Skylight,Without Curb,Nonresidential,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,Skylight,Without Curb,Residential,U 1.36 SHGC 0.19 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,,, -90.1-2010,ClimateZone 0,Skylight,Without Curb,Semiheated,U 1.36 SHGC 0.36 Simple Glazing Skylight,,0,2,1.36,TRUE,TRUE,,,0.39,, -90.1-2013,ClimateZone 0,ExteriorDoor,Swinging,Nonresidential,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorDoor,NonSwinging,Nonresidential,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorDoor,Swinging,Residential,Typical Insulated Metal Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorDoor,NonSwinging,Residential,Typical Overhead Door,,,,0.5,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorDoor,Swinging,Semiheated,Typical Insulated Metal Door,,,,0.7,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorDoor,NonSwinging,Semiheated,Typical Overhead Door,,,,1.45,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorFloor,Mass,Nonresidential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorFloor,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorFloor,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorFloor,Mass,Residential,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorFloor,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorFloor,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorFloor,Mass,Semiheated,Typical Insulated Exterior Mass Floor,,,,0.322,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorFloor,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Floor,,,,0.35,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorFloor,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Floor,,,,0.282,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorFloor,Mass,Adiabatic,Adiabatic ExteriorFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 0,ExteriorRoof,IEAD,Nonresidential,Typical IEAD Roof - Highly Reflective,,,,0.048,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorRoof,Metal Building,Nonresidential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorRoof,Attic and Other,Nonresidential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorRoof,IEAD,Residential,Typical IEAD Roof - Highly Reflective,,,,0.039,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorRoof,Metal Building,Residential,Typical Insulated Metal Building Roof - Highly Reflective,,,,0.041,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorRoof,Attic and Other,Residential,Typical Wood Joist Attic Floor,,,,0.027,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorRoof,IEAD,Semiheated,Typical IEAD Roof,,,,0.218,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorRoof,Metal Building,Semiheated,Typical Insulated Metal Building Roof,,,,0.1156,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorRoof,Attic and Other,Semiheated,Typical Wood Joist Attic Floor,,,,0.081,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorRoof,Attic and Other,Adiabatic,Adiabatic Roof,,,0,,,,,,,, -90.1-2013,ClimateZone 0,ExteriorWall,Mass,Nonresidential,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorWall,Metal Building,Nonresidential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorWall,SteelFramed,Nonresidential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorWall,WoodFramed,Nonresidential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorWall,Mass,Residential,Typical Insulated Exterior Mass Wall,,,,0.151,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorWall,Metal Building,Residential,Typical Insulated Metal Building Wall,,,,0.094,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorWall,SteelFramed,Residential,Typical Insulated Steel Framed Exterior Wall,,,,0.124,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorWall,WoodFramed,Residential,Typical Insulated Wood Framed Exterior Wall,,,,0.089,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorWall,Mass,Semiheated,Typical Insulated Exterior Mass Wall,,,,0.58,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorWall,Metal Building,Semiheated,Typical Insulated Metal Building Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorWall,SteelFramed,Semiheated,Typical Insulated Steel Framed Exterior Wall,,,,0.352,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorWall,WoodFramed,Semiheated,Typical Insulated Wood Framed Exterior Wall,,,,0.292,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,ExteriorWall,Mass,Adiabatic,Adiabatic Wall,,,0,,,,,,,, -90.1-2013,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Nonresidential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Nonresidential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 0,ExteriorWindow,Metal framing (all other),Nonresidential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Residential,U 0.5 SHGC 0.25 Simple Glazing Window,,,,0.5,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Residential,U 0.57 SHGC 0.25 Simple Glazing Window,,,,0.57,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 0,ExteriorWindow,Metal framing (all other),Residential,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 0,ExteriorWindow,Nonmetal framing (all),Semiheated,U 0.93 SHGC 0.25 Simple Glazing Window,,,,0.93,TRUE,TRUE,,,0.25,, -90.1-2013,ClimateZone 0,ExteriorWindow,Metal framing (curtainwall/storefront),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2013,ClimateZone 0,ExteriorWindow,Metal framing (all other),Semiheated,U 1.1 SHGC 0.25 Simple Glazing Window,,,,1.1,TRUE,TRUE,,,0.25,, -90.1-2013,ClimateZone 0,GlassDoor,Metal framing (entrance door),Nonresidential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 0,GlassDoor,Metal framing (entrance door),Residential,U 0.65 SHGC 0.25 Simple Glazing Window,,,,0.65,TRUE,TRUE,,,0.25,1.1, -90.1-2013,ClimateZone 0,GlassDoor,Metal framing (entrance door),Semiheated,U 1.2 SHGC 0.25 Simple Glazing Window,,,,1.2,TRUE,TRUE,,,0.25,, -90.1-2013,ClimateZone 0,GroundContactFloor,Unheated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 0,GroundContactFloor,Heated,Nonresidential,Typical Insulated Carpeted 8in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2013,ClimateZone 0,GroundContactFloor,Unheated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 0,GroundContactFloor,Heated,Residential,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2013,ClimateZone 0,GroundContactFloor,Unheated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,0.73,,,, -90.1-2013,ClimateZone 0,GroundContactFloor,Heated,Semiheated,Typical Insulated Carpeted 6in Slab Floor,,,,,TRUE,TRUE,1.02,,,, -90.1-2013,ClimateZone 0,GroundContactFloor,Unheated,Adiabatic,Adiabatic GroundContactFloor,,,0,,,,,,,, -90.1-2013,ClimateZone 0,GroundContactWall,Mass,Nonresidential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2013,ClimateZone 0,GroundContactWall,Mass,Residential,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2013,ClimateZone 0,GroundContactWall,Mass,Semiheated,Typical Insulated Basement Mass Wall,,,,,TRUE,TRUE,,1.14,,, -90.1-2013,ClimateZone 0,Skylight,Glass with Curb,Nonresidential,U 0.75 SHGC 0.45 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,Skylight,Glass with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.49,, -90.1-2013,ClimateZone 0,Skylight,Glass with Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,0.49,, -90.1-2013,ClimateZone 0,Skylight,Plastic with Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.39,, -90.1-2013,ClimateZone 0,Skylight,Plastic with Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,Skylight,Plastic with Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,,, -90.1-2013,ClimateZone 0,Skylight,Without Curb,Nonresidential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.68,, -90.1-2013,ClimateZone 0,Skylight,Without Curb,Residential,U 0.75 SHGC 0.35 Simple Glazing Skylight,,0,2,0.75,TRUE,TRUE,,,0.64,, -90.1-2013,ClimateZone 0,Skylight,Without Curb,Semiheated,U 1.80 SHGC 0.36 Simple Glazing Skylight,,0,2,1.8,TRUE,TRUE,,,0.64,, diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_boilers_90_1.csv b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_boilers_90_1.csv deleted file mode 100644 index 608e4841f6..0000000000 --- a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_boilers_90_1.csv +++ /dev/null @@ -1,22 +0,0 @@ -template,fluid_type,fuel_type,condensing,condensing_control,minimum_capacity,maximum_capacity,start_date,end_date,minimum_annual_fuel_utilization_efficiency,minimum_thermal_efficiency,minimum_combustion_efficiency,efffplr,annotation -90.1-2004,Hot Water,Gas,,,0,299999,9/9/1919,9/9/2999,0.8,,,Boiler with No Minimum Turndown,From 90.1-2004 -90.1-2004,Hot Water,Gas,,,300000,249999999,9/9/1919,9/9/2999,,0.75,,Boiler with No Minimum Turndown,From 90.1-2004 -90.1-2004,Hot Water,Gas,,,250000000,9999999999,9/9/1919,9/9/2999,,,0.8,Boiler with No Minimum Turndown,From 90.1-2004 -90.1-2007,Hot Water,Gas,,,0,299999,9/9/1919,9/9/2999,0.8,,,Boiler with No Minimum Turndown,From 90.1-2007 -90.1-2007,Hot Water,Gas,,,300000,249999999,9/9/1919,9/9/2999,,0.8,,Boiler with No Minimum Turndown,From 90.1-2007 -90.1-2007,Hot Water,Gas,,,250000000,9999999999,9/9/1919,9/9/2999,,,0.82,Boiler with No Minimum Turndown,From 90.1-2007 -90.1-2010,Hot Water,Gas,,,0,299999,9/9/1919,9/9/2999,0.8,,,Boiler with No Minimum Turndown,From 90.1-2010 -90.1-2010,Hot Water,Gas,,,300000,249999999,9/9/1919,9/9/2999,,0.8,,Boiler with No Minimum Turndown,From 90.1-2010 -90.1-2010,Hot Water,Gas,,,250000000,9999999999,9/9/1919,9/9/2999,,,0.82,Boiler with No Minimum Turndown,From 90.1-2010 -90.1-2013,Hot Water,Gas,,,0,299999,9/9/1919,9/9/2999,0.82,,,Boiler with No Minimum Turndown,From 90.1-2013 -90.1-2013,Hot Water,Gas,,,300000,999999,9/9/1919,9/9/2999,,0.8,,Boiler with No Minimum Turndown,From 90.1-2013 -90.1-2013,Hot Water,Gas,,,1000000,249999999,9/9/1919,9/9/2999,,0.8,,Boiler with Minimum Turndown,From 90.1-2013 -90.1-2013,Hot Water,Gas,,,250000000,9999999999,9/9/1919,9/9/2999,,,0.82,Boiler with Minimum Turndown,From 90.1-2013 -90.1-2016,Hot Water,Gas,,,0,299999,9/9/1919,9/9/2999,0.82,,,Boiler with No Minimum Turndown,From 90.1-2016 -90.1-2016,Hot Water,Gas,,,300000,999999,9/9/1919,9/9/2999,,0.8,,Boiler with No Minimum Turndown,From 90.1-2016 -90.1-2016,Hot Water,Gas,,,1000000,249999999,9/9/1919,9/9/2999,,0.8,,Boiler with Minimum Turndown,From 90.1-2016 -90.1-2016,Hot Water,Gas,,,250000000,9999999999,9/9/1919,9/9/2999,,,0.82,Boiler with Minimum Turndown,From 90.1-2016 -90.1-2019,Hot Water,Gas,,,0,299999,9/9/1919,9/9/2999,0.84,,,Boiler with No Minimum Turndown,From 90.1-2019 -90.1-2019,Hot Water,Gas,,,300000,999999,9/9/1919,9/9/2999,,0.8,,Boiler with No Minimum Turndown,From 90.1-2019 -90.1-2019,Hot Water,Gas,,,1000000,249999999,9/9/1919,9/9/2999,,0.8,,Boiler with Minimum Turndown,From 90.1-2019 -90.1-2019,Hot Water,Gas,,,250000000,9999999999,9/9/1919,9/9/2999,,,0.82,Boiler with Minimum Turndown,From 90.1-2019 diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_chillers_90_1.csv b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_chillers_90_1.csv deleted file mode 100644 index c904371f30..0000000000 --- a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_chillers_90_1.csv +++ /dev/null @@ -1,163 +0,0 @@ -template,cooling_type,condenser_type,compressor_type,absorption_type,variable_speed_drive,minimum_capacity,maximum_capacity,start_date,end_date,minimum_full_load_efficiency,minimum_integrated_part_load_value,capft,eirft,eirfplr,annotation -90.1-2004,AirCooled,WithCondenser,,,,0,9999,9/9/1919,9/9/2999,1.256,1.153,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR, -90.1-2004,AirCooled,WithoutCondenser,,,,0,9999,9/9/1919,9/9/2999,1.135,1.019,ChlrAirRecipQRatio_fTchwsToadbSI,ChlrAirRecipEIRRatio_fTchwsToadbSI,ChlrAirRecipEIRRatio_fQRatio, -90.1-2004,AirCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.862,,,,, -90.1-2007,AirCooled,WithCondenser,,,,0,9999,9/9/1919,9/9/2999,1.29,1.164,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Form 90.1-2007 Table 6.8.1A -90.1-2010,AirCooled,WithCondenser,,,,0,149.99,9/9/1919,9/9/2999,1.255,0.941,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR, -90.1-2010,AirCooled,WithCondenser,,,,150,9999,9/9/1919,9/9/2999,1.255,0.941,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR, -90.1-2010,AirCooled,WithoutCondenser,,,,0,9999,9/9/1919,9/9/2999,1.255,0.941,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR, -90.1-2010,AirCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.862,,,,, -90.1-2013,AirCooled,WithCondenser,,,,0,149.99,9/9/1919,12/31/2014,1.25,0.96,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies -90.1-2013,AirCooled,WithCondenser,,,,150,9999,9/9/1919,12/31/2014,1.25,0.94,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies -90.1-2013,AirCooled,WithoutCondenser,,,,0,149.99,9/9/1919,12/31/2014,1.25,0.96,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,AirCooled,WithoutCondenser,,,,150,9999,9/9/1919,12/31/2014,1.25,0.94,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,AirCooled,,,Single Effect,,0,9999,9/9/1919,12/31/2014,5.862,,,,,Path A Efficiencies -90.1-2013,AirCooled,WithCondenser,,,,0,149.99,1/1/2015,12/31/2014,1.188,0.876,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies -90.1-2013,AirCooled,WithCondenser,,,,150,9999,1/1/2015,9/9/2999,1.188,0.857,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies -90.1-2013,AirCooled,WithoutCondenser,,,,0,149.99,1/1/2015,9/9/2999,1.188,0.876,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,AirCooled,WithoutCondenser,,,,150,9999,1/1/2015,9/9/2999,1.188,0.857,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,AirCooled,,,Single Effect,,0,9999,1/1/2015,9/9/2999,5.862,,,,,Path A Efficiencies -90.1-2004,WaterCooled,,Reciprocating,,,0,149.99,9/9/1919,9/9/2999,0.837,0.696,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, -90.1-2004,WaterCooled,,Reciprocating,,,150,9999,9/9/1919,9/9/2999,0.837,0.696,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, -90.1-2004,WaterCooled,,Rotary Screw,,,0,149.99,9/9/1919,9/9/2999,0.79,0.676,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, -90.1-2004,WaterCooled,,Rotary Screw,,,150,299.99,9/9/1919,9/9/2999,0.718,0.628,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, -90.1-2004,WaterCooled,,Rotary Screw,,,300,9999,9/9/1919,9/9/2999,0.639,0.572,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, -90.1-2004,WaterCooled,,Scroll,,,0,149.99,9/9/1919,9/9/2999,0.79,0.676,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, -90.1-2004,WaterCooled,,Scroll,,,150,299.99,9/9/1919,9/9/2999,0.718,0.628,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, -90.1-2004,WaterCooled,,Scroll,,,300,9999,9/9/1919,9/9/2999,0.639,0.572,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio, -90.1-2004,WaterCooled,,Centrifugal,,,150,299.99,9/9/1919,9/9/2999,0.634,0.596,WaterCooled_Centrifugal_Chiller_LT150_2004_CAPFT,WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio, -90.1-2004,WaterCooled,,Centrifugal,,,0,149.99,9/9/1919,9/9/2999,0.703,0.67,WaterCooled_Centrifugal_Chiller_LT150_2004_CAPFT,WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio, -90.1-2004,WaterCooled,,Centrifugal,,,300,9999,9/9/1919,9/9/2999,0.577,0.55,WaterCooled_Centrifugal_Chiller_GT150_2004_CAPFT,WaterCooled_Centrifugal_Chiller_GT150_2004_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio, -90.1-2004,WaterCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.024,,,,, -90.1-2007,WaterCooled,,Reciprocating,,,0,74.99,9/9/1919,9/9/2999,0.78,0.63,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Reciprocating,,,75,149.99,9/9/1919,9/9/2999,0.775,0.615,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Reciprocating,,,150,299.99,9/9/1919,9/9/2999,0.68,0.58,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Reciprocating,,,300,9999,9/9/1919,9/9/2999,0.62,0.54,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Scroll,,,0,74.99,9/9/1919,9/9/2999,0.78,0.63,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Scroll,,,75,149.99,9/9/1919,9/9/2999,0.775,0.615,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Scroll,,,150,299.99,9/9/1919,9/9/2999,0.68,0.58,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Scroll,,,300,9999,9/9/1919,9/9/2999,0.62,0.54,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Rotary Screw,,,0,74.99,9/9/1919,9/9/2999,0.78,0.63,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Rotary Screw,,,75,149.99,9/9/1919,9/9/2999,0.775,0.615,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Rotary Screw,,,150,299.99,9/9/1919,9/9/2999,0.68,0.58,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Rotary Screw,,,300,9999,9/9/1919,9/9/2999,0.62,0.54,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Centrifugal,,,0,149.99,9/9/1919,9/9/2999,0.634,0.596,WaterCooled_Centrifugal_Chiller_LT150_2004_CAPFT,WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Centrifugal,,,150,299.99,9/9/1919,9/9/2999,0.634,0.596,WaterCooled_Centrifugal_Chiller_LT150_2004_CAPFT,WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Centrifugal,,,300,599.99,9/9/1919,9/9/2999,0.576,0.549,WaterCooled_Centrifugal_Chiller_GT150_2004_CAPFT,WaterCooled_Centrifugal_Chiller_GT150_2004_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2007,WaterCooled,,Centrifugal,,,600,9999,9/9/1919,9/9/2999,0.57,0.539,WaterCooled_Centrifugal_Chiller_GT150_2004_CAPFT,WaterCooled_Centrifugal_Chiller_GT150_2004_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Reciprocating,,,0,74.99,9/9/1919,9/9/2999,0.78,0.63,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Reciprocating,,,75,149.99,9/9/1919,9/9/2999,0.775,0.615,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Reciprocating,,,150,299.99,9/9/1919,9/9/2999,0.68,0.58,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Reciprocating,,,300,9999,9/9/1919,9/9/2999,0.62,0.54,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Scroll,,,0,74.99,9/9/1919,9/9/2999,0.78,0.63,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Scroll,,,75,149.99,9/9/1919,9/9/2999,0.775,0.615,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Scroll,,,150,299.99,9/9/1919,9/9/2999,0.68,0.58,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Scroll,,,300,9999,9/9/1919,9/9/2999,0.62,0.54,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Rotary Screw,,,0,74.99,9/9/1919,9/9/2999,0.78,0.63,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Rotary Screw,,,75,149.99,9/9/1919,9/9/2999,0.775,0.615,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Rotary Screw,,,150,299.99,9/9/1919,9/9/2999,0.68,0.58,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Rotary Screw,,,300,9999,9/9/1919,9/9/2999,0.62,0.54,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Centrifugal,,,0,149.99,9/9/1919,9/9/2999,0.634,0.596,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Centrifugal,,,150,299.99,9/9/1919,9/9/2999,0.634,0.596,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Centrifugal,,,300,599.99,9/9/1919,9/9/2999,0.576,0.549,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,Centrifugal,,,600,9999,9/9/1919,9/9/2999,0.57,0.539,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Minimum Efficiencies -90.1-2010,WaterCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.024,,,,, -90.1-2013,WaterCooled,,Reciprocating,,,0,74.99,9/9/1919,12/31/2014,0.78,0.63,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Reciprocating,,,75,149.99,9/9/1919,12/31/2014,0.775,0.615,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Reciprocating,,,150,299.99,9/9/1919,12/31/2014,0.68,0.58,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Reciprocating,,,300,599.99,9/9/1919,12/31/2014,0.62,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Reciprocating,,,600,9999,9/9/1919,12/31/2014,0.62,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Scroll,,,0,74.99,9/9/1919,12/31/2014,0.78,0.63,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Scroll,,,75,149.99,9/9/1919,12/31/2014,0.775,0.615,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Scroll,,,150,299.99,9/9/1919,12/31/2014,0.68,0.58,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Scroll,,,300,599.99,9/9/1919,12/31/2014,0.62,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Scroll,,,600,9999,9/9/1919,12/31/2014,0.62,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Rotary Screw,,,0,74.99,9/9/1919,12/31/2014,0.78,0.63,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Rotary Screw,,,75,149.99,9/9/1919,12/31/2014,0.775,0.615,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Rotary Screw,,,150,299.99,9/9/1919,12/31/2014,0.68,0.58,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Rotary Screw,,,300,599.99,9/9/1919,12/31/2014,0.62,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Rotary Screw,,,600,9999,9/9/1919,12/31/2014,0.62,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Centrifugal,,,0,149.99,9/9/1919,12/31/2014,0.634,0.596,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Centrifugal,,,150,399.99,9/9/1919,12/31/2014,0.634,0.596,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Centrifugal,,,400,599.99,9/9/1919,12/31/2014,0.576,0.549,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Centrifugal,,,600,9999,9/9/1919,12/31/2014,0.57,0.539,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Add but unsure what to put for Minimum full load efficiency and min IPLV -90.1-2013,WaterCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.024,,,,,Path A Efficiencies -90.1-2013,WaterCooled,,Reciprocating,,,0,74.99,1/1/2015,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Reciprocating,,,75,149.99,1/1/2015,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Reciprocating,,,150,299.99,1/1/2015,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Reciprocating,,,300,599.99,1/1/2015,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Reciprocating,,,600,9999,1/1/2015,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Scroll,,,0,74.99,1/1/2015,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Scroll,,,75,149.99,1/1/2015,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Scroll,,,150,299.99,1/1/2015,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Scroll,,,300,599.99,1/1/2015,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Scroll,,,600,9999,1/1/2015,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Rotary Screw,,,0,74.99,1/1/2015,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Rotary Screw,,,75,149.99,1/1/2015,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Rotary Screw,,,150,299.99,1/1/2015,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Rotary Screw,,,300,599.99,1/1/2015,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Rotary Screw,,,600,9999,1/1/2015,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Centrifugal,,,0,149.99,1/1/2015,9/9/2999,0.61,0.55,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Centrifugal,,,150,399.99,1/1/2015,9/9/2999,0.56,0.52,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Centrifugal,,,400,599.99,1/1/2015,9/9/2999,0.56,0.5,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2013,WaterCooled,,Centrifugal,,,600,9999,1/1/2015,9/9/2999,0.56,0.5,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Add but unsure what to put for Minimum full load efficiency and min IPLV -90.1-2004,,,,Double Effect Indirect Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.35,,,, -90.1-2004,,,,Double Effect Direct Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.517,,,, -90.1-2010,,,,Double Effect Indirect Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.35,,,, -90.1-2010,,,,Double Effect Direct Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.517,,,, -90.1-2013,,,,Double Effect Indirect Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.35,,,,Path A Efficiencies -90.1-2013,,,,Double Effect Direct Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.517,,,,Path A Efficiencies -90.1-2016,AirCooled,WithCondenser,,,,0,149.99,9/9/1919,9/9/2999,1.188,0.876,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies -90.1-2016,AirCooled,WithCondenser,,,,150,9999,9/9/1919,9/9/2999,1.188,0.857,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies -90.1-2016,AirCooled,WithoutCondenser,,,,0,149.99,9/9/1919,9/9/2999,1.188,0.876,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,AirCooled,WithoutCondenser,,,,150,9999,9/9/1919,9/9/2999,1.188,0.857,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,AirCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.862,,,,,Path A Efficiencies -90.1-2016,WaterCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.024,,,,,Path A Efficiencies -90.1-2016,WaterCooled,,Reciprocating,,,0,74.99,9/9/1919,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Reciprocating,,,75,149.99,9/9/1919,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Reciprocating,,,150,299.99,9/9/1919,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Reciprocating,,,300,599.99,9/9/1919,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Reciprocating,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Scroll,,,0,74.99,9/9/1919,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Scroll,,,75,149.99,9/9/1919,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Scroll,,,150,299.99,9/9/1919,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Scroll,,,300,599.99,9/9/1919,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Scroll,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Rotary Screw,,,0,74.99,9/9/1919,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Rotary Screw,,,75,149.99,9/9/1919,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Rotary Screw,,,150,299.99,9/9/1919,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Rotary Screw,,,300,599.99,9/9/1919,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Rotary Screw,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Centrifugal,,,0,149.99,9/9/1919,9/9/2999,0.61,0.55,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Centrifugal,,,150,399.99,9/9/1919,9/9/2999,0.56,0.52,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Centrifugal,,,400,599.99,9/9/1919,9/9/2999,0.56,0.5,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,WaterCooled,,Centrifugal,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2016,,,,Double Effect Indirect Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.35,,,,Path A Efficiencies -90.1-2016,,,,Double Effect Direct Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.517,,,,Path A Efficiencies -90.1-2019,AirCooled,WithCondenser,,,,0,149.99,9/9/1919,9/9/2999,1.188,0.876,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies -90.1-2019,AirCooled,WithCondenser,,,,150,9999,9/9/1919,9/9/2999,1.188,0.857,AirCooled_Chiller_2010_PathA_CAPFT,AirCooled_Chiller_2010_PathA_EIRFT,AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Path A Efficiencies -90.1-2019,AirCooled,WithoutCondenser,,,,0,149.99,9/9/1919,9/9/2999,1.188,0.876,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,AirCooled,WithoutCondenser,,,,150,9999,9/9/1919,9/9/2999,1.188,0.857,ChlrAirScrollQRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fTchwsToadbSI,ChlrAirScrollEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,AirCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.862,,,,,Path A Efficiencies -90.1-2019,WaterCooled,,,Single Effect,,0,9999,9/9/1919,9/9/2999,5.024,,,,,Path A Efficiencies -90.1-2019,WaterCooled,,Reciprocating,,,0,74.99,9/9/1919,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Reciprocating,,,75,149.99,9/9/1919,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Reciprocating,,,150,299.99,9/9/1919,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Reciprocating,,,300,599.99,9/9/1919,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Reciprocating,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Scroll,,,0,74.99,9/9/1919,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Scroll,,,75,149.99,9/9/1919,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Scroll,,,150,299.99,9/9/1919,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Scroll,,,300,599.99,9/9/1919,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Scroll,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Rotary Screw,,,0,74.99,9/9/1919,9/9/2999,0.75,0.6,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Rotary Screw,,,75,149.99,9/9/1919,9/9/2999,0.72,0.56,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Rotary Screw,,,150,299.99,9/9/1919,9/9/2999,0.66,0.54,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Rotary Screw,,,300,599.99,9/9/1919,9/9/2999,0.61,0.52,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Rotary Screw,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Centrifugal,,,0,149.99,9/9/1919,9/9/2999,0.61,0.55,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Centrifugal,,,150,399.99,9/9/1919,9/9/2999,0.56,0.52,WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Centrifugal,,,400,599.99,9/9/1919,9/9/2999,0.56,0.5,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,WaterCooled,,Centrifugal,,,600,9999,9/9/1919,9/9/2999,0.56,0.5,WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,ChlrWtrCentPathAAllEIRRatio_fQRatio,Path A Efficiencies -90.1-2019,,,,Double Effect Indirect Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.35,,,,Path A Efficiencies -90.1-2019,,,,Double Effect Direct Fired,,0,9999,9/9/1919,9/9/2999,3.517,3.517,,,,Path A Efficiencies diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_furnaces_90_1.csv b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_furnaces_90_1.csv deleted file mode 100644 index 7bbcdb7238..0000000000 --- a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_furnaces_90_1.csv +++ /dev/null @@ -1,13 +0,0 @@ -template,minimum_capacity,maximum_capacity,start_date,end_date,minimum_annual_fuel_utilization_efficiency,minimum_thermal_efficiency,minimum_combustion_efficiency,annotation -90.1-2004,0,224999,9/9/1919,9/9/2999,0.78,0.8,,Table 6.8.1E page 49 -90.1-2004,225000,249999999,9/9/1919,9/9/2999,,,0.8,Table 6.8.1E page 49 -90.1-2007,0,224999,9/9/1919,9/9/2999,0.78,0.8,,Table 6.8.1E page 49 -90.1-2007,225000,249999999,9/9/1919,9/9/2999,,,0.8,Table 6.8.1E page 49 -90.1-2010,0,224999,9/9/1919,9/9/2999,0.78,0.8,,Table 6.8.1E page 62 -90.1-2010,225000,249999999,9/9/1919,9/9/2999,,0.8,,Table 6.8.1E page 62 -90.1-2013,0,224999,9/9/1919,9/9/2999,0.78,0.8,,Table 6.8.1E page 72 -90.1-2013,225000,249999999,9/9/1919,9/9/2999,,0.8,,Table 6.8.1E page 72 -90.1-2016,0,224999,9/9/1919,9/9/2999,0.78,0.8,,Table 6.8.1E page 116 -90.1-2016,225000,249999999,9/9/1919,9/9/2999,,0.8,,Table 6.8.1E page 116 -90.1-2019,0,224999,9/9/1919,9/9/2999,,0.81,,Table 6.8.1-6 for > 225 ktbu/hr; Table F-4 for < 225 ktbu/hr -90.1-2019,225000,249999999,9/9/1919,9/9/2999,,0.8,,Table 6.8.1-6 for > 225 ktbu/hr; Table F-4 for < 225 ktbu/hr diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_pump_cooling_90_1.csv b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_pump_cooling_90_1.csv deleted file mode 100644 index 3ea90977be..0000000000 --- a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_pump_cooling_90_1.csv +++ /dev/null @@ -1,165 +0,0 @@ -template,cooling_type,heating_type,subcategory,minimum_capacity,maximum_capacity,start_date,end_date,minimum_seasonal_efficiency,minimum_full_load_efficiency,minimum_iplv,minimum_integrated_energy_efficiency_ratio,pthp_eer_coefficient_1,pthp_eer_coefficient_2,cool_cap_ft,cool_cap_fflow,cool_eir_ft,cool_eir_fflow,cool_plf_fplr,annotation -90.1-2004,AirCooled,Electric Resistance or None,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,12.3,0.213,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1D -90.1-2004,AirCooled,All Other,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,12.3,0.213,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1D -90.1-2007,AirCooled,Electric Resistance or None,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,12.3,0.213,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2007 Table 6.8.1D -90.1-2007,AirCooled,All Other,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,12.3,0.213,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2007 Table 6.8.1D -90.1-2010,AirCooled,Electric Resistance or None,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,12.3,0.213,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1D Before 10/8/2012 -90.1-2010,AirCooled,All Other,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,12.3,0.213,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1D Before 10/8/2012 -90.1-2013,AirCooled,Electric Resistance or None,PTHP,0,9999999,9/9/1919,12/31/2015,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2013 Table 6.8.1-4 -90.1-2013,AirCooled,All Other,PTHP,0,9999999,9/9/1919,12/31/2015,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2013 Table 6.8.1-4 -90.1-2013,AirCooled,Electric Resistance or None,PTHP,0,9999999,1/1/2016,9/9/2999,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2013 Table 6.8.1-4 -90.1-2013,AirCooled,All Other,PTHP,0,9999999,1/1/2016,9/9/2999,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2013 Table 6.8.1-4 -90.1-2004,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,9.7,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2004,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,9.7,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2004,ThroughWall,Electric Resistance or None,Single Package,0,29999,9/9/1919,9/9/2999,9.7,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2004,ThroughWall,All Other,Single Package,0,29999,9/9/1919,9/9/2999,9.7,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2004,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B -90.1-2004,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,9.9,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B -90.1-2004,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,9.3,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B -90.1-2004,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,9.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B -90.1-2004,AirCooled,Electric Resistance or None,Single Package,240000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B -90.1-2004,AirCooled,All Other,Single Package,240000,9999999,9/9/1919,9/9/2999,,8.8,9,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B -90.1-2007,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" -90.1-2007,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" -90.1-2007,ThroughWall,Electric Resistance or None,Single Package,0,29999,9/9/1919,9/9/2999,10.6,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" -90.1-2007,ThroughWall,All Other,Single Package,0,29999,9/9/1919,9/9/2999,10.6,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" -90.1-2007,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" -90.1-2007,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,9.9,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" -90.1-2007,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,9.3,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" -90.1-2007,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,9.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" -90.1-2007,AirCooled,Electric Resistance or None,Single Package,240000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" -90.1-2007,AirCooled,All Other,Single Package,240000,9999999,9/9/1919,9/9/2999,,8.8,9,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" -90.1-2010,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,ThroughWall,Electric Resistance or None,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,ThroughWall,All Other,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,11,,11.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,10.8,,11,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,10.6,,10.7,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,10.4,,10.5,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,Electric Resistance or None,Single Package,240000,9999999,9/9/1919,9/9/2999,,9.5,,9.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,All Other,Single Package,240000,9999999,9/9/1919,9/9/2999,,9.3,,9.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2013,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,12/31/2014,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 -90.1-2013,AirCooled,All Other,Single Package,0,64999,9/9/1919,12/31/2014,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 -90.1-2013,AirCooled,Electric Resistance or None,Single Package,0,64999,1/1/2015,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 -90.1-2013,AirCooled,All Other,Single Package,0,64999,1/1/2015,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 -90.1-2013,ThroughWall,Electric Resistance or None,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 -90.1-2013,ThroughWall,All Other,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 -90.1-2013,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,12/31/2015,,11,,11.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,Electric Resistance or None,Single Package,65000,134999,1/1/2016,9/9/2999,,11,,12.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,All Other,Single Package,65000,134999,9/9/1919,12/31/2015,,10.8,,11,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,All Other,Single Package,65000,134999,1/1/2016,9/9/2999,,10.8,,12,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,12/31/2015,,10.6,,10.7,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,Electric Resistance or None,Single Package,135000,239999,1/1/2016,9/9/2999,,10.6,,11.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,All Other,Single Package,135000,239999,9/9/1919,12/31/2015,,10.4,,10.5,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,All Other,Single Package,135000,239999,1/1/2016,9/9/2999,,10.4,,11.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,Electric Resistance or None,Single Package,240000,9999999,9/9/1919,12/31/2015,,9.5,,9.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,Electric Resistance or None,Single Package,240000,9999999,1/1/2016,9/9/2999,,9.5,,10.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,All Other,Single Package,240000,9999999,9/9/1919,12/31/2015,,9.3,,9.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,All Other,Single Package,240000,9999999,1/1/2016,9/9/2999,,9.3,,0.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2004,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,10,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2004,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,10,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2004,ThroughWall,Electric Resistance or None,Split System,0,29999,9/9/1919,9/9/2999,10,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2004,ThroughWall,All Other,Split System,0,29999,9/9/1919,9/9/2999,10,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2004,SmallDuctHighVelocity,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,10,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B -90.1-2004,SmallDuctHighVelocity,All Other,Split System,0,64999,9/9/1919,9/9/2999,10,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B -90.1-2004,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B -90.1-2004,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,9.9,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B -90.1-2004,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,9.3,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B -90.1-2004,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,9.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B -90.1-2004,AirCooled,Electric Resistance or None,Split System,240000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B -90.1-2004,AirCooled,All Other,Split System,240000,9999999,9/9/1919,9/9/2999,,8.8,9,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2004 Table 6.8.1B -90.1-2007,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" -90.1-2007,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" -90.1-2007,ThroughWall,Electric Resistance or None,Split System,0,29999,9/9/1919,9/9/2999,10.9,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" -90.1-2007,ThroughWall,All Other,Split System,0,29999,9/9/1919,9/9/2999,10.9,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" -90.1-2007,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" -90.1-2007,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,9.9,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" -90.1-2007,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,9.3,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" -90.1-2007,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,9.1,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" -90.1-2007,AirCooled,Electric Resistance or None,Split System,240000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" -90.1-2007,AirCooled,All Other,Split System,240000,9999999,9/9/1919,9/9/2999,,8.8,9,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" -90.1-2010,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,ThroughWall,Electric Resistance or None,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,ThroughWall,All Other,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,11,,11.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,10.8,,11,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,10.6,,10.7,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,10.4,,10.5,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,Electric Resistance or None,Split System,240000,9999999,9/9/1919,9/9/2999,,9.5,,9.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,All Other,Split System,240000,9999999,9/9/1919,9/9/2999,,9.3,,9.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2013,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,12/31/2014,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 -90.1-2013,AirCooled,All Other,Split System,0,64999,9/9/1919,12/31/2014,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 -90.1-2013,AirCooled,Electric Resistance or None,Split System,0,64999,1/1/2015,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 -90.1-2013,AirCooled,All Other,Split System,0,64999,1/1/2015,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2015 -90.1-2013,ThroughWall,Electric Resistance or None,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 -90.1-2013,ThroughWall,All Other,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 -90.1-2013,SmallDuctHighVelocity,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,11,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,SmallDuctHighVelocity,All Other,Split System,0,64999,9/9/1919,9/9/2999,11,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,12/31/2015,,11,,11.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,Electric Resistance or None,Split System,65000,134999,1/1/2016,9/9/2999,,11,,12.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,All Other,Split System,65000,134999,9/9/1919,12/31/2015,,10.8,,11,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,All Other,Split System,65000,134999,1/1/2016,9/9/2999,,10.8,,12,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,12/31/2015,,10.6,,10.7,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,Electric Resistance or None,Split System,135000,239999,1/1/2016,9/9/2999,,10.6,,11.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,All Other,Split System,135000,239999,9/9/1919,12/31/2015,,10.4,,10.5,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,All Other,Split System,135000,239999,1/1/2016,9/9/2999,,10.4,,11.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,Electric Resistance or None,Split System,240000,9999999,9/9/1919,12/31/2015,,9.5,,9.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,Electric Resistance or None,Split System,240000,9999999,1/1/2016,9/9/2999,,9.5,,10.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,All Other,Split System,240000,9999999,9/9/1919,12/31/2015,,9.3,,9.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2013,AirCooled,All Other,Split System,240000,9999999,1/1/2016,9/9/2999,,9.3,,0.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR,From 90.1-2010 Table 6.8.1-2 Before 1/1/2016 -90.1-2016,AirCooled,Electric Resistance or None,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,All Other,PTHP,0,9999999,9/9/1919,9/9/2999,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,ThroughWall,Electric Resistance or None,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,ThroughWall,All Other,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,11,,12.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,10.8,,12,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,10.6,,11.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,10.4,,11.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,Electric Resistance or None,Single Package,240000,9999999,9/9/1919,9/9/2999,,9.5,,10.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,All Other,Single Package,240000,9999999,9/9/1919,9/9/2999,,9.3,,0.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,ThroughWall,Electric Resistance or None,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,ThroughWall,All Other,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,SmallDuctHighVelocity,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,11,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,SmallDuctHighVelocity,All Other,Split System,0,64999,9/9/1919,9/9/2999,11,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,11,,12.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,10.8,,12,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,10.6,,11.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,10.4,,11.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,Electric Resistance or None,Split System,240000,9999999,9/9/1919,9/9/2999,,9.5,,10.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,All Other,Split System,240000,9999999,9/9/1919,9/9/2999,,9.3,,0.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,PTHP,0,6999,9/9/1919,9/9/2999,,11.9,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,PTHP,0,6999,9/9/1919,9/9/2999,,11.9,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,PTHP,7000,14999,1/1/2016,9/9/2999,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,PTHP,7000,14999,1/1/2016,9/9/2999,,,,,14,0.3,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,PTHP,15000,9999999,9/9/1919,9/9/2999,,9.5,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,PTHP,15000,9999999,9/9/1919,9/9/2999,,9.5,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,12/31/2014,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,Single Package,0,64999,9/9/1919,12/31/2014,13,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,ThroughWall,Electric Resistance or None,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,ThroughWall,All Other,Single Package,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,11,,12.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,10.8,,12,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,10.6,,11.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,10.4,,11.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,Single Package,240000,9999999,9/9/1919,9/9/2999,,9.5,,10.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,Single Package,240000,9999999,9/9/1919,9/9/2999,,9.3,,0.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,14,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,ThroughWall,Electric Resistance or None,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,ThroughWall,All Other,Split System,0,29999,9/9/1919,9/9/2999,12,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,SmallDuctHighVelocity,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,11,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,SmallDuctHighVelocity,All Other,Split System,0,64999,9/9/1919,9/9/2999,11,,,,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,11,,12.2,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,10.8,,12,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,10.6,,11.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,10.4,,11.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,Split System,240000,9999999,9/9/1919,9/9/2999,,9.5,,10.6,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,Split System,240000,9999999,9/9/1919,9/9/2999,,9.3,,0.4,,,HPACCoolCapFT,HPACCoolCapFFF,HPACCOOLEIRFT,HPACCOOLEIRFFF,HPACCOOLPLFFPLR, diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_pump_heating_90_1.csv b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_pump_heating_90_1.csv deleted file mode 100644 index b5fe02a2c7..0000000000 --- a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_pump_heating_90_1.csv +++ /dev/null @@ -1,51 +0,0 @@ -template,cooling_type,subcategory,minimum_capacity,maximum_capacity,start_date,end_date,minimum_heating_seasonal_performance_factor,minimum_coefficient_of_performance_heating,minimum_energy_efficiency_ratio,pthp_cop_coefficient_1,pthp_cop_coefficient_2,heat_cap_ft,heat_cap_fflow,heat_eir_ft,heat_eir_fflow,heat_plf_fplr,annotation -90.1-2004,AirCooled,PTHP,0,9999999,9/9/1919,9/9/2999,,,,3.2,0.026,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2004 Table 6.8.1D -90.1-2007,AirCooled,PTHP,0,9999999,9/9/1919,9/9/2999,,,,3.2,0.026,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2007 Table 6.8.1D -90.1-2010,AirCooled,PTHP,0,9999999,9/9/1919,9/9/2999,,,,3.2,0.026,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2010 Table 6.8.1D before 10/08/2012 -90.1-2013,AirCooled,PTHP,0,9999999,9/9/1919,9/9/2999,,,,3.7,0.052,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2013 Table 6.8.1-4 -90.1-2004,AirCooled,Single Package,0,64999,9/9/1919,9/9/2999,6.6,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2004,ThroughWall,Single Package,0,29999,9/9/1919,9/9/2999,6.6,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2004,AirCooled,Single Package,65000,134999,9/9/1919,9/9/2999,,3.2,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2004,AirCooled,Single Package,135000,9999999,9/9/1919,9/9/2999,,3.1,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2007,AirCooled,Single Package,0,64999,9/9/1919,9/9/2999,7.7,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" -90.1-2007,ThroughWall,Single Package,0,29999,9/9/1919,9/9/2999,7,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" -90.1-2007,AirCooled,Single Package,65000,134999,9/9/1919,9/9/2999,,3.2,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" -90.1-2007,AirCooled,Single Package,135000,9999999,9/9/1919,9/9/2999,,3.1,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2007 Table 6.8.1B, Before 1/1/2010" -90.1-2010,AirCooled,Single Package,0,64999,9/9/1919,9/9/2999,7.7,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,ThroughWall,Single Package,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,Single Package,65000,134999,9/9/1919,9/9/2999,,3.3,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,AirCooled,Single Package,135000,9999999,9/9/1919,9/9/2999,,3.2,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2013,AirCooled,Single Package,0,64999,9/9/1919,12/31/2014,7.7,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2013 Table 6.8.1-2, Before 1/1/2015" -90.1-2013,AirCooled,Single Package,0,64999,1/1/2015,9/9/2999,8,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2013 Table 6.8.1-2, Before 1/1/2015" -90.1-2013,ThroughWall,Single Package,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2013 Table 6.8.1-3 -90.1-2013,AirCooled,Single Package,65000,134999,9/9/1919,9/9/2999,,3.3,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR,From 90.1-2013 Table 6.8.1-5 -90.1-2013,AirCooled,Single Package,135000,9999999,9/9/1919,9/9/2999,,3.2,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR,From 90.1-2013 Table 6.8.1-6 -90.1-2004,AirCooled,Split System,0,64999,9/9/1919,9/9/2999,6.8,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2004,ThroughWall,Split System,0,29999,9/9/1919,9/9/2999,6.8,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2004,SmallDuctHighVelocity,Split System,0,64999,9/9/1919,9/9/2999,6.8,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2004 Table 6.8.1B, Before 1/23/2006" -90.1-2007,AirCooled,Split System,0,64999,9/9/1919,9/9/2999,7.7,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" -90.1-2007,ThroughWall,Split System,0,29999,9/9/1919,9/9/2999,7.1,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,"From 90.1-2007 Table 6.8.1B, As of 1/23/2006" -90.1-2010,AirCooled,Split System,0,64999,9/9/1919,9/9/2999,7.7,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2010,ThroughWall,Split System,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2010 Table 6.8.1B -90.1-2013,AirCooled,Split System,0,64999,9/9/1919,12/31/2014,7.7,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2013 Table 6.8.1-2, Before 1/1/2015" -90.1-2013,AirCooled,Split System,0,64999,1/1/2015,9/9/2999,8.2,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR,"From 90.1-2013 Table 6.8.1-2, Before 1/1/2015" -90.1-2013,ThroughWall,Split System,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2013 Table 6.8.1-2 -90.1-2013,SmallDuctHighVelocity,Split System,0,64999,9/9/1919,9/9/2999,6.8,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR,From 90.1-2013 Table 6.8.1-4 -90.1-2016,AirCooled,PTHP,0,9999999,9/9/1919,9/9/2999,,,,3.7,0.052,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, -90.1-2016,AirCooled,Single Package,0,64999,9/9/1919,9/9/2999,8,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,ThroughWall,Single Package,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, -90.1-2016,AirCooled,Single Package,65000,134999,9/9/1919,9/9/2999,,3.3,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,Single Package,135000,9999999,9/9/1919,9/9/2999,,3.2,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,Split System,0,64999,9/9/1919,9/9/2999,8.2,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, -90.1-2016,ThroughWall,Split System,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, -90.1-2016,SmallDuctHighVelocity,Split System,0,64999,9/9/1919,9/9/2999,6.8,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, -90.1-2019,AirCooled,PTHP,0,6999,9/9/1919,9/9/2999,,3.3,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, -90.1-2019,AirCooled,PTHP,6999,14999,9/9/1919,9/9/2999,,,,3.7,0.052,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, -90.1-2019,AirCooled,PTHP,14999,9999999,9/9/1919,9/9/2999,,2.9,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, -90.1-2019,AirCooled,Single Package,0,64999,9/9/1919,9/9/2999,8,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,ThroughWall,Single Package,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, -90.1-2019,AirCooled,Single Package,65000,134999,9/9/1919,9/9/2999,,3.3,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Single Package,135000,9999999,9/9/1919,9/9/2999,,3.2,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Split System,0,64999,9/9/1919,9/9/2999,8.2,,,,,HPACHeatCapFT,HPACHeatCapFFF,HPACHeatEIRFT,HPACHeatEIRFFF,HPACCOOLPLFFPLR, -90.1-2019,ThroughWall,Split System,0,29999,9/9/1919,9/9/2999,7.4,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, -90.1-2019,SmallDuctHighVelocity,Split System,0,64999,9/9/1919,9/9/2999,6.8,,,,,DXHEAT-NECB2011-REF-CAPFT,DXHEAT-NECB2011-REF-CAPFFLOW,DXHEAT-NECB2011-REF-EIRFT,DXHEAT-NECB2011-REF-EIRFFLOW,DXHEAT-NECB2011-REF-PLFFPLR, diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_rejection_90_1.csv b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_rejection_90_1.csv deleted file mode 100644 index 886007d819..0000000000 --- a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_heat_rejection_90_1.csv +++ /dev/null @@ -1,31 +0,0 @@ -template,equipment_type,fan_type,start_date,end_date,minimum_performance_gpm_per_hp,annotation -90.1-2004,Open Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2004 Table 6.8.1G -90.1-2004,Open Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,38.2,From 90.1-2004 Table 6.8.1G -90.1-2004,Closed Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2004 Table 6.8.1G -90.1-2004,Closed Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,38.2,From 90.1-2004 Table 6.8.1G -90.1-2004,Dry Cooler,Propeller or Axial,9/9/1919,9/9/2999,4,Not required by code. Value provided by 90.1 Mechanical Subcommittee -90.1-2007,Open Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2007 Table 6.8.1G -90.1-2007,Open Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,38.2,From 90.1-2007 Table 6.8.1G -90.1-2007,Closed Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2007 Table 6.8.1G -90.1-2007,Closed Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,38.2,From 90.1-2007 Table 6.8.1G -90.1-2007,Dry Cooler,Propeller or Axial,9/9/1919,9/9/2999,4,Not required by code. Value provided by 90.1 Mechanical Subcommittee -90.1-2010,Open Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2010 Table 6.8.1 G -90.1-2010,Open Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,38.2,From 90.1-2010 Table 6.8.1 G -90.1-2010,Closed Cooling Tower,Centrifugal,9/9/1919,9/9/2999,7,From 90.1-2010 Table 6.8.1 G -90.1-2010,Closed Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,14,From 90.1-2010 Table 6.8.1 G -90.1-2010,Dry Cooler,Propeller or Axial,9/9/1919,9/9/2999,4,Not required by code. Value provided by 90.1 Mechanical Subcommittee -90.1-2013,Open Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2013 Table 6.8.1-7 -90.1-2013,Open Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,40.2,From 90.1-2013 Table 6.8.1-7 -90.1-2013,Closed Cooling Tower,Centrifugal,9/9/1919,9/9/2999,7,From 90.1-2013 Table 6.8.1-7 -90.1-2013,Closed Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,14,From 90.1-2013 Table 6.8.1-7 -90.1-2013,Dry Cooler,Propeller or Axial,9/9/1919,9/9/2999,4,NOTE: Not required by code. Value provided by 90.1 Mechanical Subcommittee -90.1-2016,Open Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2016 Table 6.8.1-7 -90.1-2016,Open Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,40.2,From 90.1-2016 Table 6.8.1-7 -90.1-2016,Closed Cooling Tower,Centrifugal,9/9/1919,9/9/2999,7,From 90.1-2016 Table 6.8.1-7 -90.1-2016,Closed Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,16.1,From 90.1-2016 Table 6.8.1-7 -90.1-2016,Dry Cooler,Propeller or Axial,9/9/1919,9/9/2999,4,NOTE Not required by code. Value provided by 90.1 Mechanical Subcommittee -90.1-2019,Open Cooling Tower,Centrifugal,9/9/1919,9/9/2999,20,From 90.1-2019 Table 6.8.1-7 -90.1-2019,Open Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,40.2,From 90.1-2019 Table 6.8.1-7 -90.1-2019,Closed Cooling Tower,Centrifugal,9/9/1919,9/9/2999,7,From 90.1-2019 Table 6.8.1-7 -90.1-2019,Closed Cooling Tower,Propeller or Axial,9/9/1919,9/9/2999,16.1,From 90.1-2019 Table 6.8.1-7 -90.1-2019,Dry Cooler,Propeller or Axial,9/9/1919,9/9/2999,4.5,From 90.1-2019 Table 6.8.1.7. Juan Gonzalez Added 01/11/2021 to account for fluid coolers in data center water loop heat pump condenser loops diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_motors_90_1.csv b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_motors_90_1.csv deleted file mode 100644 index 986abcdab9..0000000000 --- a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_motors_90_1.csv +++ /dev/null @@ -1,148 +0,0 @@ -template,number_of_poles,type,synchronous_speed,minimum_capacity,maximum_capacity,nominal_full_load_efficiency,annotation -90.1-2004,4,Enclosed,1800,0,0.999,0.29,"Motors below 1 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" -90.1-2004,4,Enclosed,1800,1,1.499,0.825,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,1.5,1.999,0.84,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,2,2.999,0.84,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,3,4.999,0.875,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,5,7.499,0.875,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,7.5,9.999,0.895,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,10,14.999,0.895,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,15,19.999,0.91,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,20,24.999,0.91,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,25,29.999,0.924,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,30,39.999,0.924,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,40,49.999,0.93,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,50,59.999,0.93,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,60,74.999,0.936,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,75,99.999,0.941,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,100,124.999,0.945,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,125,149.999,0.945,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,150,199.999,0.95,From 90.1-2004 Table 10.8 -90.1-2004,4,Enclosed,1800,200,9999,0.95,From 90.1-2004 Table 10.8 -90.1-2007,4,Enclosed,1800,0,0.999,0.29,"Motors below 1 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" -90.1-2007,4,Enclosed,1800,1,1.499,0.825,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,1.5,1.999,0.84,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,2,2.999,0.84,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,3,4.999,0.875,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,5,7.499,0.875,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,7.5,9.999,0.895,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,10,14.999,0.895,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,15,19.999,0.91,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,20,24.999,0.91,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,25,29.999,0.924,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,30,39.999,0.924,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,40,49.999,0.93,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,50,59.999,0.93,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,60,74.999,0.936,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,75,99.999,0.941,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,100,124.999,0.945,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,125,149.999,0.945,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,150,199.999,0.95,From 90.1-2007 Table 10.8 -90.1-2007,4,Enclosed,1800,200,9999,0.95,From 90.1-2007 Table 10.8 -90.1-2010,4,Enclosed,1800,0,0.999,0.29,"Motors below 1 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" -90.1-2010,4,Enclosed,1800,1,1.499,0.855,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,1.5,1.999,0.865,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,2,2.999,0.865,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,3,4.999,0.895,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,5,7.499,0.895,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,7.5,9.999,0.917,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,10,14.999,0.917,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,15,19.999,0.924,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,20,24.9999,0.93,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,25,29.999,0.936,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,30,39.999,0.936,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,40,49.999,0.941,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,50,59.999,0.945,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,60,74.999,0.95,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,75,99.999,0.954,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,100,124.999,0.954,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,125,149.999,0.954,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,150,199.999,0.958,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,200,249.999,0.962,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,250,299.999,0.962,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,300,349.999,0.962,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,350,399.999,0.962,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,400,449.999,0.962,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,450,499.999,0.962,From 90.1-2010 Table 10.8B -90.1-2010,4,Enclosed,1800,500,9999,0.962,From 90.1-2010 Table 10.8B -90.1-2013,4,Enclosed,1800,0,0.08333,0.29,"Motors below 1/12 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" -90.1-2013,4,Enclosed,1800,0.08334,0.999,0.7,"Motors between 1/12 and 1 HP must be EC, with minimum efficiency of 70% per PNNL" -90.1-2013,4,Enclosed,1800,1,1.499,0.855, -90.1-2013,4,Enclosed,1800,1.5,1.999,0.865, -90.1-2013,4,Enclosed,1800,2,2.999,0.865, -90.1-2013,4,Enclosed,1800,3,4.999,0.895, -90.1-2013,4,Enclosed,1800,5,7.499,0.895, -90.1-2013,4,Enclosed,1800,7.5,9.999,0.917, -90.1-2013,4,Enclosed,1800,10,14.999,0.917, -90.1-2013,4,Enclosed,1800,15,19.999,0.924, -90.1-2013,4,Enclosed,1800,20,24.999,0.93, -90.1-2013,4,Enclosed,1800,25,29.999,0.936, -90.1-2013,4,Enclosed,1800,30,39.999,0.936, -90.1-2013,4,Enclosed,1800,40,49.999,0.941, -90.1-2013,4,Enclosed,1800,50,59.999,0.945, -90.1-2013,4,Enclosed,1800,60,74.999,0.95, -90.1-2013,4,Enclosed,1800,75,99.999,0.954, -90.1-2013,4,Enclosed,1800,100,124.999,0.954, -90.1-2013,4,Enclosed,1800,125,149.999,0.954, -90.1-2013,4,Enclosed,1800,150,199.999,0.958, -90.1-2013,4,Enclosed,1800,200,249.999,0.962, -90.1-2013,4,Enclosed,1800,250,299.999,0.95, -90.1-2013,4,Enclosed,1800,300,349.999,0.954, -90.1-2013,4,Enclosed,1800,350,399.999,0.954, -90.1-2013,4,Enclosed,1800,400,449.999,0.954, -90.1-2013,4,Enclosed,1800,450,499.999,0.954, -90.1-2013,4,Enclosed,1800,500,9999,0.954, -90.1-2016,4,Enclosed,1800,0,0.08333,0.29,"Motors below 1/12 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" -90.1-2016,4,Enclosed,1800,0.08334,0.999,0.7,"Motors between 1/12 and 1 HP must be EC, with minimum efficiency of 70% per PNNL" -90.1-2016,4,Enclosed,1800,1,1.499,0.855, -90.1-2016,4,Enclosed,1800,1.5,1.999,0.865, -90.1-2016,4,Enclosed,1800,2,2.999,0.865, -90.1-2016,4,Enclosed,1800,3,4.999,0.895, -90.1-2016,4,Enclosed,1800,5,7.499,0.895, -90.1-2016,4,Enclosed,1800,7.5,9.999,0.917, -90.1-2016,4,Enclosed,1800,10,14.999,0.917, -90.1-2016,4,Enclosed,1800,15,19.999,0.924, -90.1-2016,4,Enclosed,1800,20,24.999,0.93, -90.1-2016,4,Enclosed,1800,25,29.999,0.936, -90.1-2016,4,Enclosed,1800,30,39.999,0.936, -90.1-2016,4,Enclosed,1800,40,49.999,0.941, -90.1-2016,4,Enclosed,1800,50,59.999,0.945, -90.1-2016,4,Enclosed,1800,60,74.999,0.95, -90.1-2016,4,Enclosed,1800,75,99.999,0.954, -90.1-2016,4,Enclosed,1800,100,124.999,0.954, -90.1-2016,4,Enclosed,1800,125,149.999,0.954, -90.1-2016,4,Enclosed,1800,150,199.999,0.958, -90.1-2016,4,Enclosed,1800,200,249.999,0.962, -90.1-2016,4,Enclosed,1800,250,299.999,0.962, -90.1-2016,4,Enclosed,1800,300,349.999,0.962, -90.1-2016,4,Enclosed,1800,350,399.999,0.962, -90.1-2016,4,Enclosed,1800,400,449.999,0.962, -90.1-2016,4,Enclosed,1800,450,499.999,0.962, -90.1-2016,4,Enclosed,1800,500,9999,0.962, -90.1-2019,4,Enclosed,1800,0,0.08333,0.29,"Motors below 1/12 HP assumed to be PSC, with average typical efficiency of 29% per PNNL" -90.1-2019,4,Enclosed,1800,0.08334,0.999,0.7,"Motors between 1/12 and 1 HP must be EC, with minimum efficiency of 70% per PNNL" -90.1-2019,4,Enclosed,1800,1,1.499,0.855, -90.1-2019,4,Enclosed,1800,1.5,1.999,0.865, -90.1-2019,4,Enclosed,1800,2,2.999,0.865, -90.1-2019,4,Enclosed,1800,3,4.999,0.895, -90.1-2019,4,Enclosed,1800,5,7.499,0.895, -90.1-2019,4,Enclosed,1800,7.5,9.999,0.917, -90.1-2019,4,Enclosed,1800,10,14.999,0.917, -90.1-2019,4,Enclosed,1800,15,19.999,0.924, -90.1-2019,4,Enclosed,1800,20,24.999,0.93, -90.1-2019,4,Enclosed,1800,25,29.999,0.936, -90.1-2019,4,Enclosed,1800,30,39.999,0.936, -90.1-2019,4,Enclosed,1800,40,49.999,0.941, -90.1-2019,4,Enclosed,1800,50,59.999,0.945, -90.1-2019,4,Enclosed,1800,60,74.999,0.95, -90.1-2019,4,Enclosed,1800,75,99.999,0.954, -90.1-2019,4,Enclosed,1800,100,124.999,0.954, -90.1-2019,4,Enclosed,1800,125,149.999,0.954, -90.1-2019,4,Enclosed,1800,150,199.999,0.958, -90.1-2019,4,Enclosed,1800,200,249.999,0.962, -90.1-2019,4,Enclosed,1800,250,299.999,0.962, -90.1-2019,4,Enclosed,1800,300,349.999,0.962, -90.1-2019,4,Enclosed,1800,350,399.999,0.962, -90.1-2019,4,Enclosed,1800,400,449.999,0.962, -90.1-2019,4,Enclosed,1800,450,499.999,0.962, -90.1-2019,4,Enclosed,1800,500,9999,0.962, diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_unitary_air_conditioners_90_1.csv b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_unitary_air_conditioners_90_1.csv deleted file mode 100644 index 51d10b80ba..0000000000 --- a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_unitary_air_conditioners_90_1.csv +++ /dev/null @@ -1,196 +0,0 @@ -template,cooling_type,heating_type,subcategory,minimum_capacity,maximum_capacity,start_date,end_date,minimum_seasonal_efficiency,minimum_energy_efficiency_ratio,minimum_integrated_part_load_value,minimum_integrated_energy_efficiency_ratio,ptac_eer_coefficient_1,ptac_eer_coefficient_2,minimum_scop,cool_cap_ft,cool_cap_fflow,cool_eir_ft,cool_eir_fflow,cool_plf_fplr,annotation -90.1-2004,AirCooled,All Other,PTAC,0,9999999,9/9/1919,9/9/2999,,,,,12.5,0.213,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2004,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,9.7,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,9.5,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,All Other,Single Package,240000,759999,9/9/1919,9/9/2999,,9.3,9.5,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,All Other,Single Package,760000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,10,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,9.5,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,All Other,Split System,240000,759999,9/9/1919,9/9/2999,,9.3,9.5,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,All Other,Split System,760000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,Electric Resistance or None,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.2,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2004 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" -90.1-2004,AirCooled,Electric Resistance or None,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.1,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2004 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" -90.1-2004,AirCooled,Electric Resistance or None,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,1.9,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2004 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" -90.1-2004,AirCooled,Electric Resistance or None,PTAC,0,9999999,9/9/1919,9/9/2999,,,,,12.5,0.213,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2004,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,9.7,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,10.3,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,9.7,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,Electric Resistance or None,Single Package,240000,759999,9/9/1919,9/9/2999,,9.5,9.7,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,Electric Resistance or None,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.2,9.4,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,10,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,10.3,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,9.7,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,Electric Resistance or None,Split System,240000,759999,9/9/1919,9/9/2999,,9.5,9.7,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,AirCooled,Electric Resistance or None,Split System,760000,9999999,9/9/1919,9/9/2999,,9.2,9.4,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2004,WaterCooled,All Other,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.6,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2004 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" -90.1-2004,WaterCooled,All Other,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.5,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2004 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" -90.1-2004,WaterCooled,All Other,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,2.4,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2004 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" -90.1-2007,AirCooled,All Other,PTAC,0,9999999,9/9/1919,9/9/2999,,,,,12.5,0.213,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2007,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,9.5,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,All Other,Single Package,240000,759999,9/9/1919,9/9/2999,,9.3,9.5,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,All Other,Single Package,760000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,10.1,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,9.5,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,All Other,Split System,240000,759999,9/9/1919,9/9/2999,,9.3,9.5,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,All Other,Split System,760000,9999999,9/9/1919,9/9/2999,,9,9.2,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,Electric Resistance or None,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.2,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2007 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" -90.1-2007,AirCooled,Electric Resistance or None,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.1,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2007 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" -90.1-2007,AirCooled,Electric Resistance or None,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,1.9,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2007 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units" -90.1-2007,AirCooled,Electric Resistance or None,PTAC,0,9999999,9/9/1919,9/9/2999,,,,,12.5,0.213,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2007,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,10.3,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,9.7,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,Electric Resistance or None,Single Package,240000,759999,9/9/1919,9/9/2999,,9.5,9.7,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,Electric Resistance or None,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.2,9.4,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,10.3,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,9.7,,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,Electric Resistance or None,Split System,240000,759999,9/9/1919,9/9/2999,,9.5,9.7,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,AirCooled,Electric Resistance or None,Split System,760000,9999999,9/9/1919,9/9/2999,,9.2,9.4,,,,,CoilClgDXQRatio_fTwbToadbSI,CoilClgDXSnglQRatio_fCFMRatio,CoilClgDXEIRRatio_fTwbToadbSI,CoilClgDXSnglEIRRatio_fCFMRatio,CoilClgDXEIRRatio_fQFrac, -90.1-2007,WaterCooled,All Other,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.6,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2007 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" -90.1-2007,WaterCooled,All Other,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.5,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2007 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" -90.1-2007,WaterCooled,All Other,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,2.4,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,"2007 not specified, follow ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units" -90.1-2010,AirCooled,All Other,PTAC,0,9999999,9/9/1919,9/9/2999,,,,,13.8,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2010,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2010,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,11,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2010,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,10.8,,,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, -90.1-2010,AirCooled,All Other,Single Package,240000,759999,9/9/1919,9/9/2999,,9.8,,9.7,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, -90.1-2010,AirCooled,All Other,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.5,,9.2,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, -90.1-2010,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2010,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,11,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2010,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,10.8,,,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, -90.1-2010,AirCooled,All Other,Split System,240000,759999,9/9/1919,9/9/2999,,9.8,,9.7,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, -90.1-2010,AirCooled,All Other,Split System,760000,9999999,9/9/1919,9/9/2999,,9.5,,9.2,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, -90.1-2010,AirCooled,Electric Resistance or None,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.2,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for downflow units -90.1-2010,AirCooled,Electric Resistance or None,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.1,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for downflow units -90.1-2010,AirCooled,Electric Resistance or None,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,1.9,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for downflow units -90.1-2010,AirCooled,Electric Resistance or None,PTAC,0,9999999,9/9/1919,9/9/2999,,,,,13.8,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2010,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2010,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,11.2,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2010,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,11,,,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, -90.1-2010,AirCooled,Electric Resistance or None,Single Package,240000,759999,9/9/1919,9/9/2999,,10,,9.7,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, -90.1-2010,AirCooled,Electric Resistance or None,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.7,,9.4,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, -90.1-2010,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2010,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,11.2,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2010,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,11,,,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, -90.1-2010,AirCooled,Electric Resistance or None,Split System,240000,759999,9/9/1919,9/9/2999,,10,,9.7,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, -90.1-2010,AirCooled,Electric Resistance or None,Split System,760000,9999999,9/9/1919,9/9/2999,,9.7,,9.4,,,,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,AHU-1_CoolCStandard10Ton_CapFF,PSZ-AC_CoolCStandard10Ton_EIRFT,CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR, -90.1-2010,WaterCooled,All Other,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.6,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units -90.1-2010,WaterCooled,All Other,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.5,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units -90.1-2010,WaterCooled,All Other,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,2.4,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2010 Table 6.8.1K. capacity here is sensible only. SCOP for water cooled downflow units -90.1-2013,AirCooled,All Other,PTAC,0,9999999,9/9/1919,12/31/2014,,,,,13.8,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2013,AirCooled,All Other,PTAC,0,9999999,1/1/2015,9/9/2999,,,,,14,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2013,AirCooled,All Other,Single Package,0,64999,9/9/1919,12/31/2014,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Single Package,0,64999,1/1/2015,9/9/2999,14,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Single Package,65000,134999,9/9/1919,12/31/2015,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Single Package,135000,239999,9/9/1919,12/31/2015,,10.8,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Single Package,240000,759999,9/9/1919,12/31/2015,,9.8,,9.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Single Package,760000,9999999,9/9/1919,12/31/2015,,9.5,,9.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Single Package,65000,134999,1/1/2016,9/9/2999,,11,,12.7,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Single Package,135000,239999,1/1/2016,9/9/2999,,10.8,,12.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Single Package,240000,759999,1/1/2016,9/9/2999,,9.8,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Single Package,760000,9999999,1/1/2016,9/9/2999,,9.5,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Split System,65000,134999,9/9/1919,12/31/2015,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Split System,135000,239999,9/9/1919,12/31/2015,,10.8,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Split System,240000,759999,9/9/1919,12/31/2015,,9.8,,9.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Split System,760000,9999999,9/9/1919,12/31/2015,,9.5,,9.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Split System,65000,134999,1/1/2016,9/9/2999,,11,,12.7,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Split System,135000,239999,1/1/2016,9/9/2999,,10.8,,12.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Split System,240000,759999,1/1/2016,9/9/2999,,9.8,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,All Other,Split System,760000,9999999,1/1/2016,9/9/2999,,9.5,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.2,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units -90.1-2013,AirCooled,Electric Resistance or None,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.1,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units -90.1-2013,AirCooled,Electric Resistance or None,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,1.9,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units -90.1-2013,AirCooled,Electric Resistance or None,PTAC,0,9999999,9/9/1919,12/31/2014,,,,,13.8,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2013,AirCooled,Electric Resistance or None,PTAC,0,9999999,1/1/2015,9/9/2999,,,,,14,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2013,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,12/31/2014,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Single Package,0,64999,1/1/2015,9/9/2999,14,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,12/31/2015,,11.2,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,12/31/2015,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Single Package,240000,759999,9/9/1919,12/31/2015,,10,,10.1,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Single Package,760000,9999999,9/9/1919,12/31/2015,,9.7,,9.8,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Single Package,65000,134999,1/1/2016,9/9/2999,,11.2,,12.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Single Package,135000,239999,1/1/2016,9/9/2999,,11,,12.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Single Package,240000,759999,1/1/2016,9/9/2999,,10,,11.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Single Package,760000,9999999,1/1/2016,9/9/2999,,9.7,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,12/31/2015,,11.2,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,12/31/2015,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Split System,240000,759999,9/9/1919,12/31/2015,,10,,10.1,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Split System,760000,9999999,9/9/1919,12/31/2015,,9.7,,9.8,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Split System,65000,134999,1/1/2016,9/9/2999,,11.2,,12.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Split System,135000,239999,1/1/2016,9/9/2999,,11,,12.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Split System,240000,759999,1/1/2016,9/9/2999,,10,,11.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,AirCooled,Electric Resistance or None,Split System,760000,9999999,1/1/2016,9/9/2999,,9.7,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2013,WaterCooled,All Other,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.6,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units -90.1-2013,WaterCooled,All Other,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.5,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units -90.1-2013,WaterCooled,All Other,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,2.4,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units -90.1-2016,AirCooled,All Other,PTAC,0,9999999,9/9/1919,12/31/2014,,,,,13.8,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,All Other,PTAC,0,9999999,1/1/2015,9/9/2999,,,,,14,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,14,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,10.8,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,All Other,Single Package,240000,759999,9/9/1919,9/9/2999,,9.8,,9.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,All Other,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.5,,9.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,10.8,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,All Other,Split System,240000,759999,9/9/1919,9/9/2999,,9.8,,9.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,All Other,Split System,760000,9999999,9/9/1919,9/9/2999,,9.5,,9.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,Electric Resistance or None,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.3,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units -90.1-2016,AirCooled,Electric Resistance or None,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.2,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units -90.1-2016,AirCooled,Electric Resistance or None,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,2,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units -90.1-2016,AirCooled,Electric Resistance or None,PTAC,0,9999999,9/9/1919,12/31/2014,,,,,13.8,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,Electric Resistance or None,PTAC,0,9999999,1/1/2015,9/9/2999,,,,,14,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2016,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,12/31/2014,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,Electric Resistance or None,Single Package,0,64999,1/1/2015,9/9/2999,14,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,11.2,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,Electric Resistance or None,Single Package,240000,759999,9/9/1919,9/9/2999,,10,,10.1,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,Electric Resistance or None,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.7,,9.8,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,11.2,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,11,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,Electric Resistance or None,Split System,240000,759999,9/9/1919,9/9/2999,,10,,10.1,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,AirCooled,Electric Resistance or None,Split System,760000,9999999,9/9/1919,9/9/2999,,9.7,,9.8,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2016,WaterCooled,All Other,CRAC,0,64999,9/9/1919,9/9/2999,,,,,,,2.5,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units -90.1-2016,WaterCooled,All Other,CRAC,65000,239999,9/9/1919,9/9/2999,,,,,,,2.4,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units -90.1-2016,WaterCooled,All Other,CRAC,240000,9999999,9/9/1919,9/9/2999,,,,,,,2.25,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2016 Table 6.8.1-11. capacity here is sensible only. SCOP for water cooled downflow units -90.1-2019,AirCooled,All Other,PTAC,0,6999,9/9/1919,9/9/2999,,11.9,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,PTAC,6999,14999,9/9/1919,9/9/2999,,,,,14,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,PTAC,14999,9999999,9/9/1919,9/9/2999,,9.5,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,All Other,Single Package,0,64999,9/9/1919,9/9/2999,14,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,All Other,Single Package,65000,134999,9/9/1919,9/9/2999,,11,,12.7,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,All Other,Single Package,135000,239999,9/9/1919,9/9/2999,,10.8,,12.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,All Other,Single Package,240000,759999,9/9/1919,9/9/2999,,9.8,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,All Other,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.5,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,All Other,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,All Other,Split System,65000,134999,9/9/1919,9/9/2999,,11,,12.7,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,All Other,Split System,135000,239999,9/9/1919,9/9/2999,,10.8,,12.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,All Other,Split System,240000,759999,9/9/1919,9/9/2999,,9.8,,11.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,All Other,Split System,760000,9999999,9/9/1919,9/9/2999,,9.5,,11,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,Electric Resistance or None,CRAC,0,79999,9/9/1919,9/9/2999,,,,,,,2.7,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for downflow units -90.1-2019,AirCooled,Electric Resistance or None,CRAC,80000,294999,9/9/1919,9/9/2999,,,,,,,2.58,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for downflow units -90.1-2019,AirCooled,Electric Resistance or None,CRAC,295000,9999999,9/9/1919,9/9/2999,,,,,,,2.36,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for downflow units -90.1-2019,AirCooled,Electric Resistance or None,PTAC,0,6999,9/9/1919,9/9/2999,,11.9,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,PTAC,6999,14999,9/9/1919,9/9/2999,,,,,14,0.3,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,PTAC,14999,9999999,9/9/1919,9/9/2999,,9.5,,,,,,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR, -90.1-2019,AirCooled,Electric Resistance or None,Single Package,0,64999,9/9/1919,9/9/2999,14,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,Electric Resistance or None,Single Package,65000,134999,9/9/1919,9/9/2999,,11.2,,12.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,Electric Resistance or None,Single Package,135000,239999,9/9/1919,9/9/2999,,11,,12.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,Electric Resistance or None,Single Package,240000,759999,9/9/1919,9/9/2999,,10,,11.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,Electric Resistance or None,Single Package,760000,9999999,9/9/1919,9/9/2999,,9.7,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,Electric Resistance or None,Split System,0,64999,9/9/1919,9/9/2999,13,,,,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,Electric Resistance or None,Split System,65000,134999,9/9/1919,9/9/2999,,11.2,,12.9,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,Electric Resistance or None,Split System,135000,239999,9/9/1919,9/9/2999,,11,,12.4,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,Electric Resistance or None,Split System,240000,759999,9/9/1919,9/9/2999,,10,,11.6,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,AirCooled,Electric Resistance or None,Split System,760000,9999999,9/9/1919,9/9/2999,,9.7,,11.2,,,,PSZ-AC_Unitary_PackagecoolCapFT,PSZ-AC_Unitary_PackagecoolFFF,PSZ-AC DX Unitary Package EIRFT,PSZ-AC_Unitary_PackagecoolEIRFFF,PSZ-AC_Unitary_PackagecoolPLR, -90.1-2019,WaterCooled,All Other,CRAC,0,79999,9/9/1919,9/9/2999,,,,,,,2.82,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for water cooled downflow units -90.1-2019,WaterCooled,All Other,CRAC,80000,294999,9/9/1919,9/9/2999,,,,,,,2.73,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for water cooled downflow units -90.1-2019,WaterCooled,All Other,CRAC,295000,9999999,9/9/1919,9/9/2999,,,,,,,2.67,PSZ-Fine Storage DX Coil Cap-FT,DX Coil Cap-FF,PSZ-AC DX Coil EIR-FT,Split DX Coil EIR-FF,HPACCOOLPLFFPLR,ASHRAE 90.1-2019 Table 6.8.1-10. capacity here is sensible only. SCOP for water cooled downflow units diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_heaters_90_1.csv b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_heaters_90_1.csv deleted file mode 100644 index 67ef79f434..0000000000 --- a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_heaters_90_1.csv +++ /dev/null @@ -1,25 +0,0 @@ -template,fuel_type,minimum_capacity,maximum_capacity,start_date,end_date,energy_factor_base,energy_factor_volume_derate,standby_loss_base,standby_loss_capacity_allowance,standby_loss_volume_allowance,hourly_loss_base,hourly_loss_volume_allowance,thermal_efficiency,annotation -90.1-2004,Electricity,0,40945.99,9/9/1919,9/9/2999,0.93,0.00132,,,,,,,From 90.1-2004 Table 7.8 -90.1-2004,Electricity,40946,99999999,9/9/1919,9/9/2999,,,20,,35,,,,From 90.1-2004 Table 7.8 -90.1-2004,NaturalGas,0,74999.99,9/9/1919,9/9/2999,0.62,0.0019,,,,,,,From 90.1-2004 Table 7.8 -90.1-2004,NaturalGas,75000,99999999,9/9/1919,9/9/2999,,,,800,110,,,0.8,From 90.1-2004 Table 7.8 -90.1-2007,Electricity,0,40945.99,9/9/1919,9/9/2999,0.93,0.00132,,,,,,,From 90.1-2007 Table 7.8 -90.1-2007,Electricity,40946,99999999,9/9/1919,9/9/2999,,,20,,35,,,,From 90.1-2007 Table 7.8 -90.1-2007,NaturalGas,0,74999.99,9/9/1919,9/9/2999,0.62,0.0019,,,,,,,From 90.1-2007 Table 7.8 -90.1-2007,NaturalGas,75000,99999999,9/9/1919,9/9/2999,,,,800,110,,,0.8,From 90.1-2007 Table 7.8 -90.1-2010,Electricity,0,40945.99,9/9/1919,9/9/2999,0.97,0.00132,,,,,,,From 90.1-2010 Table 7.8 -90.1-2010,Electricity,40946,99999999,9/9/1919,9/9/2999,,,20,,35,,,,From 90.1-2010 Table 7.8 -90.1-2010,NaturalGas,0,74999.99,9/9/1919,9/9/2999,0.67,0.0019,,,,,,,From 90.1-2010 Table 7.8 -90.1-2010,NaturalGas,75000,99999999,9/9/1919,9/9/2999,,,,800,110,,,0.8,From 90.1-2010 Table 7.8 -90.1-2013,Electricity,0,40945.99,9/9/1919,9/9/2999,0.97,0.00132,,,,,,,From 90.1-2013 Table 7.8 -90.1-2013,Electricity,40946,99999999,9/9/1919,9/9/2999,,,,,,0.3,27,,From 90.1-2013 Table 7.8 -90.1-2013,NaturalGas,0,74999.99,9/9/1919,9/9/2999,0.67,0.0019,,,,,,,From 90.1-2013 Table 7.8 -90.1-2013,NaturalGas,75000,99999999,9/9/1919,9/9/2999,,,,800,110,,,0.8,From 90.1-2013 Table 7.8 -90.1-2016,Electricity,0,40945.99,9/9/1919,9/9/2999,0.96,0.0003,,,,,,,"From 90.1-2016 Table F-2, Rated Storage Volume <= 55 gal" -90.1-2016,Electricity,40946,99999999,9/9/1919,9/9/2999,,,,,,0.3,27,, -90.1-2016,NaturalGas,0,74999.99,9/9/1919,9/9/2999,0.675,0.0015,,,,,,,"From 90.1-2016 Table F-2, Rated Storage Volume <= 55 gal" -90.1-2016,NaturalGas,75000,99999999,9/9/1919,9/9/2999,,,,800,110,,,0.8, -90.1-2019,Electricity,0,40945.99,9/9/1919,9/9/2999,0.96,0.0003,,,,,,,Same as 90.1-2016 as placeholder; 90.1-2019 Table F-2 uses UEF -90.1-2019,Electricity,40946,99999999,9/9/1919,9/9/2999,,,,,,0.3,27,, -90.1-2019,NaturalGas,0,74999.99,9/9/1919,9/9/2999,0.675,0.0015,,,,,,,Same as 90.1-2016 as placeholder; 90.1-2019 Table F-2 uses UEF -90.1-2019,NaturalGas,75000,99999999,9/9/1919,9/9/2999,,,,800,110,,,0.8, diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1.csv b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1.csv deleted file mode 100644 index 3ef18bfab7..0000000000 --- a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1.csv +++ /dev/null @@ -1,19 +0,0 @@ -template,minimum_capacity,maximum_capacity,start_date,end_date,minimum_full_load_efficiency,annotation -90.1-2004,0,16999,9/9/1919,9/9/2999,11.2,From 90.1-2004 Table 6.8.1B -90.1-2004,17000,64999,9/9/1919,9/9/2999,12,From 90.1-2004 Table 6.8.1B -90.1-2004,65000,134999,9/9/1919,9/9/2999,12,From 90.1-2004 Table 6.8.1B -90.1-2007,0,16999,9/9/1919,9/9/2999,11.2,From 90.1-2007 Table 6.8.1B -90.1-2007,17000,64999,9/9/1919,9/9/2999,12,From 90.1-2007 Table 6.8.1B -90.1-2007,65000,134999,9/9/1919,9/9/2999,12,From 90.1-2007 Table 6.8.1B -90.1-2010,0,16999,9/9/1919,9/9/2999,11.2,From 90.1-2010 Table 6.8.1B -90.1-2010,17000,64999,9/9/1919,9/9/2999,12,From 90.1-2010 Table 6.8.1B -90.1-2010,65000,134999,9/9/1919,9/9/2999,12,From 90.1-2010 Table 6.8.1B -90.1-2013,0,16999,9/9/1919,9/9/2999,12.2,From 90.1-2013 Table 6.8.1-2 -90.1-2013,17000,64999,9/9/1919,9/9/2999,13,From 90.1-2013 Table 6.8.1-2 -90.1-2013,65000,134999,9/9/1919,9/9/2999,13,From 90.1-2013 Table 6.8.1-2 -90.1-2016,0,16999,9/9/1919,9/9/2999,12.2, -90.1-2016,17000,64999,9/9/1919,9/9/2999,13, -90.1-2016,65000,134999,9/9/1919,9/9/2999,13, -90.1-2019,0,16999,9/9/1919,9/9/2999,12.2, -90.1-2019,17000,64999,9/9/1919,9/9/2999,13, -90.1-2019,65000,134999,9/9/1919,9/9/2999,13, diff --git a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_source_heat_pumps_heating_90_1.csv b/data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_source_heat_pumps_heating_90_1.csv deleted file mode 100644 index 2359b75f6d..0000000000 --- a/data/openstudio_standards_data/database_files/hvac_minimum_requirement_water_source_heat_pumps_heating_90_1.csv +++ /dev/null @@ -1,7 +0,0 @@ -template,minimum_capacity,maximum_capacity,start_date,end_date,minimum_coefficient_of_performance,annotation -90.1-2004,0,9999999,9/9/1919,9/9/2999,4.2,From 90.1-2004 Table 6.8.1B -90.1-2007,0,9999999,9/9/1919,9/9/2999,4.2,From 90.1-2007 Table 6.8.1B -90.1-2010,0,9999999,9/9/1919,9/9/2999,4.2,From 90.1-2010 Table 6.8.1B -90.1-2013,0,9999999,9/9/1919,9/9/2999,4.3,From 90.1-2013 Table 6.8.1-2 -90.1-2016,0,9999999,9/9/1919,9/9/2999,4.3,From 90.1-2016 Table 6.8.1-2 -90.1-2019,0,9999999,9/9/1919,9/9/2999,4.3,From 90.1-2016 Table 6.8.1-15 diff --git a/data/openstudio_standards_data/database_files/level_1_space_types.csv b/data/openstudio_standards_data/database_files/level_1_space_types.csv deleted file mode 100644 index 8c243413b2..0000000000 --- a/data/openstudio_standards_data/database_files/level_1_space_types.csv +++ /dev/null @@ -1,62 +0,0 @@ -space_type_name,lighting_space_type_name,ventilation_space_type_name,electric_equipment_space_type_name,natural_gas_equipment_space_type_name,schedule_set_name,annotation -atrium,atrium_lighting,atrium_ventilation,atrium_lt_20_ft_height_electric_equipment,,atrium_lt_20_ft_height, -attic,none_lighting,attic_ventilation,attic_electric_equipment,,attic, -audience seating,audience_seating_lighting,audience_seating_ventilation,audience_seating_all_other_electric_equipment,,audience_seating_all_other, -banking,banking_lighting,banking_ventilation,banking_activity_electric_equipment,,banking_activity, -"classroom, lecture, training",classroom_lecture_training_lighting,classroom_lecture_training_ventilation,classroom_lecture_training_all_other_electric_equipment,,classroom_lecture_training_all_other, -computer room,computer_room_lighting,computer_room_ventilation,computer_room_electric_equipment,,computer_room, -"conference, meeting, multipurpose",conference_meeting_multipurpose_lighting,conference_meeting_multipurpose_ventilation,conference_meeting_multipurpose_electric_equipment,,conference_meeting_multipurpose, -confinement cells,confinement_cells_lighting,confinement_cells_ventilation,confinement_cells_electric_equipment,,confinement_cells, -"copy, print",copy_print_lighting,copy_print_ventilation,office_enclosed_lte_250_sf_electric_equipment,,office_enclosed_lte_250_sf,to be revised -corridor,corridor_lighting,corridor_ventilation,corridor_all_other_electric_equipment,,corridor_all_other, -courtroom,courtroom_lighting,courtroom_ventilation,courtroom_electric_equipment,,courtroom, -"datacenter, high ite",datacenterhighite_lighting,datacenterhighite_ventilation,datacenter_high_ite_equipment,,computer_room,to be revised -"datacenter, low ite",datacenterlowite_lighting,datacenterlowite_ventilation,datacenter_low_ite_equipment,,computer_room,to be revised -dining,dining_lighting,dining_ventilation,dining_all_other_electric_equipment,,dining_all_other, -dressing room,dressing_room_lighting,dressing_room_ventilation,performing_arts_dressing_room_electric_equipment,,performing_arts_dressing_room, -"electrical, mechanical",electrical_mechanical_lighting,electrical_mechanical_ventilation,electrical_mechanical_electric_equipment,,electrical_mechanical, -emergency room,emergency_room_lighting,emergency_room_ventilation,emergency_room_electric_equipment,,emergency_room, -emergency vehicle garage,emergency_vehicle_garage_lighting,emergency_vehicle_garage_ventilation,emergency_vehicle_garage_electric_equipment,,emergency_vehicle_garage, -"exam, treatment",exam_treatment_lighting,exam_treatment_ventilation,exam_treatment_electric_equipment,,exam_treatment, -exercise area,exercise_area_lighting,exercise_area_ventilation,gymnasium_exercise_area_electric_equipment,,gymnasium_exercise_area, -exhibit,exhibit_lighting,exhibit_ventilation,museum_exhibit_area_electric_equipment,,museum_exhibit_area, -guest room,guest_room_lighting,guest_room_ventilation,guest_room_electric_equipment,,guest_room, -imaging,imaging_lighting,imaging_ventilation,imaging_room_equipment,,exam_treatment, -interior parking,interior_parking_lighting,interior_parking_ventilation,parking_area_interior_electric_equipment,,parking_area_interior, -judges chambers,judges_chambers_lighting,judges_chambers_ventilation,judges_chambers_electric_equipment,,judges_chambers, -food preparation,food_preparation_lighting,food_preparation_ventilation,kitchen_electric_equipment,kitchen,kitchen, -laboratory,laboratory_lighting,laboratory_ventilation,laboratory_electric_equipment,,laboratory, -"laundry, washing",laundry_washing_lighting,laundry_washing_ventilation,laundry_washing_electric_equipment,laundry,laundry_washing, -library,library_lighting,library_ventilation,library_stacks_electric_equipment,,library_stacks, -living quarters,living_quarters_lighting,living_quarters_ventilation,dormitory_living_quarters_electric_equipment,,dormitory_living_quarters,living quarters such as in a fire station -loading dock,loading_dock_lighting,loading_dock_ventilation,loading_dock_equipment,,workshop,to be revised -lobby,lobby_lighting,lobby_ventilation,lobby_all_other_electric_equipment,,lobby_all_other, -locker room,locker_room_lighting,locker_room_ventilation,locker_room_electric_equipment,,locker_room, -"lounge, breakroom",lounge_breakroom_lighting,lounge_breakroom_ventilation,lounge_breakroom_all_other_electric_equipment,,lounge_breakroom_all_other, -manufacturing,manufacturing_lighting,manufacturing_ventilation,manufacturing_low_bay_electric_equipment,,manufacturing_low_bay, -medical supply,medical_supply_lighting,medical_supply_ventilation,pharmacy_electric_equipment,,pharmacy, -multifamily,multifamily_lighting,multifamily_ventilation,multifamily_equipment,,lounge_breakroom_all_other,"common areas in a multifamily building, NOT dwelling units; schedule to be revised" -nursery,nursery_lighting,nursery_ventilation,patient_room_electric_equipment,,patient_room, -nurses station,nurses_station_lighting,nurses_station_ventilation,nurses_station_electric_equipment,,nurses_station, -office,office_lighting,office_ventilation,office_open_electric_equipment,,office_open, -"office, enclosed",office_enclosed_lighting,office_enclosed_ventilation,office_enclosed_lte_250_sf_electric_equipment,,office_enclosed_lte_250_sf, -operating room,operating_room_lighting,operating_room_ventilation,operating_room_electric_equipment,,operating_room, -patient room,patient_room_lighting,patient_room_ventilation,patient_room_electric_equipment,,patient_room, -pharmacy,pharmacy_lighting,pharmacy_ventilation,pharmacy_electric_equipment,,pharmacy, -physical therapy,physical_therapy_lighting,physical_therapy_ventilation,physical_therapy_electric_equipment,,physical_therapy, -playing area,playing_area_lighting,playing_area_ventilation,gymnasium_playing_area_electric_equipment,,gymnasium_playing_area, -plenum,none_lighting,plenum_ventilation,plenum_electric_equipment,,plenum, -post office,post_office_lighting,post_office_ventilation,post_office_sorting_area_electric_equipment,,post_office_sorting_area, -recovery,recovery_lighting,recovery_ventilation,patient_room_electric_equipment,,patient_room, -"recreation, common living",recreation_common_living_lighting,recreation_common_living_ventilation,lounge_breakroom_all_other_electric_equipment,,lounge_breakroom_all_other, -restroom,restroom_lighting,restroom_ventilation,restroom_all_other_electric_equipment,,restroom_all_other, -retail,retail_sales_lighting,retail_sales_ventilation,sales_electric_equipment,,sales, -shaft,none_lighting,shaft_ventilation,shaft_electric_equipment,,shaft, -sleeping quarters,sleeping_quarters_lighting,sleeping_quarters_ventilation,firestation_sleeping_quarters_electric_equipment,,firestation_sleeping_quarters,sleeping quarters such as in a dormitory -sports arena,sports_arena_lighting,sports_arena_ventilation,sports_arena_playing_area_class_ii_electric_equipment,,sports_arena_playing_area_class_ii, -stairwell,stairwell_lighting,stairwell_ventilation,stairwell_electric_equipment,,stairwell, -storage,storage_lighting,storage_ventilation,storage_50_to_1000_sf_all_other_electric_equipment,,storage_50_to_1000_sf_all_other, -transportation,transportation_lighting,transportation_ventilation,transportation_ticket_counter_electric_equipment,,transportation_ticket_counter, -vehicular maintenance,vehicular_maintenance_lighting,vehicular_maintenance_ventilation,vehicular_maintenance_electric_equipment,,vehicular_maintenance, -workshop,workshop_lighting,workshop_ventilation,workshop_electric_equipment,,workshop, -worship,worship_lighting,worship_ventilation,worship_pulpit_choir_area_electric_equipment,,worship_pulpit_choir_area, diff --git a/data/openstudio_standards_data/database_files/level_2_electric_equipment.csv b/data/openstudio_standards_data/database_files/level_2_electric_equipment.csv deleted file mode 100644 index 258b1fca37..0000000000 --- a/data/openstudio_standards_data/database_files/level_2_electric_equipment.csv +++ /dev/null @@ -1,99 +0,0 @@ -electric_equipment_space_type_name,electric_equipment_minimum_epd,electric_equipment_average_epd,electric_equipment_median_epd,electric_equipment_maximum_epd,electric_equipment_epd_unit,electric_equipment_fraction_latent,electric_equipment_fraction_radiant,electric_equipment_fraction_lost -corridor_all_other_electric_equipment,0,0.28,0.24,0.82,W/ft2,0,0,0 -dining_all_other_electric_equipment,0.32,0.55,0.55,0.82,W/ft2,0,0,0 -electrical_mechanical_electric_equipment,0,0,0,0,W/ft2,0,0,0 -kitchen_electric_equipment,0.3,0.76,0.71,2.52,W/ft2,0.25,0.5,0.1 -laboratory_electric_equipment,0.49,0.78,0.7,2.02,W/ft2,0,0,0 -lobby_all_other_electric_equipment,0.16,0.41,0.35,0.83,W/ft2,0,0,0 -locker_room_electric_equipment,0,0.38,0.44,0.97,W/ft2,0,0,0 -lounge_breakroom_all_other_electric_equipment,0,0.49,0.52,0.88,W/ft2,0,0,0 -office_enclosed_lte_250_sf_electric_equipment,0.51,0.68,0.68,0.89,W/ft2,0,0,0 -office_enclosed_gt_250_sf_electric_equipment,0.65,0.7,0.69,0.82,W/ft2,0,0,0 -office_open_electric_equipment,0.53,0.66,0.67,0.81,W/ft2,0,0,0 -restroom_all_other_electric_equipment,0,0,0,0,W/ft2,0,0,0 -stairwell_electric_equipment,0,0.25,0.25,0.53,W/ft2,0,0,0 -storage_lt_50_sf_all_other_electric_equipment,0,0,0,0,W/ft2,0,0,0 -storage_50_to_1000_sf_all_other_electric_equipment,0,0,0,0,W/ft2,0,0,0 -vehicular_maintenance_electric_equipment,0.65,0.69,0.69,0.73,W/ft2,0,0,0 -workshop_electric_equipment,0,0.54,0.57,0.74,W/ft2,0,0,0 -atrium_first_three_floors_electric_equipment,0,0.52,0.54,0.75,W/ft2,0,0,0 -audience_seating_convention_center_electric_equipment,0.63,0.63,0.63,0.63,W/ft2,0,0,0 -classroom_lecture_training_all_other_electric_equipment,0.5,0.63,0.62,0.8,W/ft2,0,0,0 -conference_meeting_multipurpose_electric_equipment,0.42,0.62,0.62,0.97,W/ft2,0,0,0 -exhibit_convention_center_electric_equipment,0.84,0.84,0.84,0.84,W/ft2,0,0,0 -gymnasium_exercise_area_electric_equipment,0.27,0.48,0.49,0.68,W/ft2,0,0,0 -gymnasium_playing_area_electric_equipment,0,0.51,0.51,1.06,W/ft2,0,0,0 -laundry_washing_electric_equipment,0,0.39,0.39,0.59,W/ft2,0,0,0 -lobby_elevator_electric_equipment,0.32,0.32,0.32,0.32,W/ft2,0,0,0 -nurses_station_electric_equipment,0,0.52,0.57,0.85,W/ft2,0,0,0 -post_office_sorting_area_electric_equipment,0,0.23,0.24,0.39,W/ft2,0,0,0 -sales_electric_equipment,0.41,0.67,0.67,0.92,W/ft2,0,0,0 -sports_arena_playing_area_class_iv_electric_equipment,0.32,0.5,0.64,0.69,W/ft2,0,0,0 -audience_seating_all_other_electric_equipment,0.31,0.49,0.46,0.75,W/ft2,0,0,0 -confinement_cells_electric_equipment,0.22,0.26,0.26,0.32,W/ft2,0,0,0 -courtroom_electric_equipment,0.25,0.4,0.4,0.56,W/ft2,0,0,0 -judges_chambers_electric_equipment,0.5,0.59,0.59,0.68,W/ft2,0,0,0 -library_stacks_electric_equipment,0,0.2,0.2,0.33,W/ft2,0,0,0 -storage_inactive_electric_equipment,0,0,0,0,W/ft2,0,0,0 -dining_bar_lounge_leisure_electric_equipment,0.5,0.5,0.5,0.5,W/ft2,0.2,0.3,0 -dining_cafeteria_fast_food_electric_equipment,0.6,0.6,0.6,0.6,W/ft2,0.2,0.3,0 -dining_family_electric_equipment,0.78,0.78,0.78,0.78,W/ft2,0.2,0.3,0 -computer_room_electric_equipment,0.69,0.7,0.69,0.73,W/ft2,0,0,0 -dormitory_living_quarters_electric_equipment,0.23,0.44,0.42,0.62,W/ft2,0,0,0 -audience_seating_exercise_center_electric_equipment,0.6,0.6,0.6,0.6,W/ft2,0,0,0 -exam_treatment_electric_equipment,0.51,0.56,0.53,0.66,W/ft2,0,0,0 -library_reading_electric_equipment,0.32,0.49,0.46,0.71,W/ft2,0,0,0 -emergency_vehicle_garage_electric_equipment,0.39,0.39,0.39,0.39,W/ft2,0,0,0 -firestation_sleeping_quarters_electric_equipment,0.37,0.37,0.37,0.37,W/ft2,0,0,0 -parking_area_interior_electric_equipment,0.11,0.27,0.3,0.32,W/ft2,0,0,0 -audience_seating_gymnasium_electric_equipment,0.64,0.64,0.64,0.64,W/ft2,0,0,0 -emergency_room_electric_equipment,0.61,0.62,0.62,0.62,W/ft2,0,0,0 -patient_room_electric_equipment,0.71,0.72,0.72,0.73,W/ft2,0,0,0 -pharmacy_electric_equipment,0.47,0.64,0.72,0.74,W/ft2,0,0,0 -corridor_hospital_electric_equipment,0.3,0.3,0.3,0.3,W/ft2,0,0,0 -fellowship_hall_religious_facility_electric_equipment,0.36,0.39,0.39,0.41,W/ft2,0,0,0 -lounge_breakroom_healthcare_facility_electric_equipment,0.75,0.75,0.75,0.75,W/ft2,0,0,0 -operating_room_electric_equipment,0.77,0.77,0.77,0.77,W/ft2,0,0,0 -physical_therapy_electric_equipment,0.73,0.73,0.73,0.73,W/ft2,0,0,0 -storage_lt_50_sf_hospital_electric_equipment,0,0,0,0,W/ft2,0,0,0 -storage_50_to_1000_sf_hospital_electric_equipment,0,0,0,0,W/ft2,0,0,0 -guest_room_electric_equipment,0.47,0.53,0.53,0.58,W/ft2,0,0,0 -lobby_hotel_electric_equipment,0.5,0.5,0.5,0.5,W/ft2,0,0,0 -library_cataloging_electric_equipment,0.21,0.21,0.21,0.21,W/ft2,0,0,0 -museum_exhibit_area_electric_equipment,0.32,0.46,0.43,0.68,W/ft2,0,0,0 -corridor_manufacturing_facility_electric_equipment,0.38,0.38,0.38,0.38,W/ft2,0,0,0 -manufacturing_equipment_room_electric_equipment,0,0,0,0,W/ft2,0,0,0 -manufacturing_low_bay_electric_equipment,0.67,0.67,0.67,0.67,W/ft2,0,0,0 -performing_arts_dressing_room_electric_equipment,0.29,0.41,0.43,0.5,W/ft2,0,0,0 -audience_seating_auditorium_electric_equipment,0.26,0.29,0.29,0.32,W/ft2,0,0,0 -audience_seating_motion_picture_theater_electric_equipment,0.28,0.28,0.28,0.28,W/ft2,0,0,0 -lobby_motion_picture_theater_electric_equipment,0.33,0.33,0.33,0.33,W/ft2,0,0,0 -dwelling_unit_electric_equipment,0.25,0.25,0.25,0.25,W/ft2,0,0,0 -museum_restoration_electric_equipment,0.21,0.21,0.21,0.21,W/ft2,0,0,0 -banking_activity_electric_equipment,0.54,0.55,0.55,0.56,W/ft2,0,0,0 -warehouse_fine_storage_electric_equipment,0,0.06,0.06,0.12,W/ft2,0,0,0 -classroom_lecture_training_penitentiary_electric_equipment,0.41,0.41,0.41,0.41,W/ft2,0,0,0 -dining_penitentiary_electric_equipment,0.35,0.35,0.35,0.35,W/ft2,0.2,0.3,0 -audience_seating_performing_arts_theater_electric_equipment,0.27,0.27,0.27,0.27,W/ft2,0,0,0 -lobby_performing_arts_theater_electric_equipment,0.33,0.33,0.33,0.33,W/ft2,0,0,0 -audience_seating_religious_facility_electric_equipment,0.41,0.41,0.41,0.41,W/ft2,0,0,0 -worship_pulpit_choir_area_electric_equipment,0.42,0.42,0.42,0.42,W/ft2,0,0,0 -classroom_lecture_training_preschool_to_12th_electric_equipment,0.67,0.67,0.67,0.67,W/ft2,0,0,0 -sports_arena_playing_area_class_ii_electric_equipment,0.32,0.48,0.48,0.64,W/ft2,0,0,0 -audience_seating_sports_arena_electric_equipment,0.38,0.38,0.38,0.38,W/ft2,0,0,0 -airport_concourse_electric_equipment,0.52,0.52,0.52,0.52,W/ft2,0,0,0 -atrium_lt_20_ft_height_electric_equipment,0.53,0.53,0.53,0.53,W/ft2,0,0,0 -atrium_gt_40_ft_height_electric_equipment,0.53,0.53,0.53,0.53,W/ft2,0,0,0 -atrium_gte_20_ft_and_lte_40_ft_in_height_electric_equipment,0.53,0.53,0.53,0.53,W/ft2,0,0,0 -baggage_carousel_electric_equipment,0.55,0.55,0.55,0.55,W/ft2,0,0,0 -seating_area_general_electric_equipment,0.25,0.25,0.25,0.25,W/ft2,0,0,0 -transportation_ticket_counter_electric_equipment,0.74,0.74,0.74,0.74,W/ft2,0,0,0 -warehouse_bulk_storage_electric_equipment,0.11,0.11,0.11,0.11,W/ft2,0,0,0 -attic_electric_equipment,0,0,0,0,W/ft2,0,0,0 -plenum_electric_equipment,0,0,0,0,W/ft2,0,0,0 -shaft_electric_equipment,0,0,0,0,W/ft2,0,0,0 -datacenter_high_ite_equipment,100,300,300,500,W/ft2,0,0.1,0 -datacenter_low_ite_equipment,40,70,70,100,W/ft2,0,0.1,0 -multifamily_equipment,0.15,0.15,0.15,0.15,W/ft2,0,0,0 -imaging_room_equipment,0.46,0.46,0.46,0.46,W/ft2,0,0,0 -loading_dock_equipment,0.48,0.48,0.48,0.48,W/ft2,0,0,0 diff --git a/data/openstudio_standards_data/database_files/level_2_lighting_space_types.csv b/data/openstudio_standards_data/database_files/level_2_lighting_space_types.csv deleted file mode 100644 index 242fc785be..0000000000 --- a/data/openstudio_standards_data/database_files/level_2_lighting_space_types.csv +++ /dev/null @@ -1,709 +0,0 @@ -lighting_space_type_name,level_3_lighting_code_definition_table,level_3_lighting_code_definition_id,lighting_technology_name,lighting_space_type_target_illuminance_setpoint,annotation -airport_concourse_lighting,level_3_lighting_90_1_2004,122,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -atrium_lighting,level_3_lighting_90_1_2004,36,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -none_lighting,level_3_lighting_90_1_2004,126,default,0,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_lighting,level_3_lighting_90_1_2004,46,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -baggage_carousel_lighting,level_3_lighting_90_1_2004,121,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -banking_lighting,level_3_lighting_90_1_2004,77,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -classroom_lecture_training_lighting,level_3_lighting_90_1_2004,48,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -computer_room_lighting,level_3_lighting_90_1_2004,48,default,710,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -conference_meeting_multipurpose_lighting,level_3_lighting_90_1_2004,49,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -confinement_cells_lighting,level_3_lighting_90_1_2004,79,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -copy_print_lighting,level_3_lighting_90_1_2004,49,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -corridor_lighting,level_3_lighting_90_1_2004,52,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -courtroom_lighting,level_3_lighting_90_1_2004,80,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -datacenterhighite_lighting,level_3_lighting_90_1_2004,60,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -datacenterlowite_lighting,level_3_lighting_90_1_2004,60,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_lighting,level_3_lighting_90_1_2004,58,default,308,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dressing_room_lighting,level_3_lighting_90_1_2004,59,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -electrical_mechanical_lighting,level_3_lighting_90_1_2004,60,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -emergency_room_lighting,level_3_lighting_90_1_2004,87,default,888,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -emergency_vehicle_garage_lighting,level_3_lighting_90_1_2004,83,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -exam_treatment_lighting,level_3_lighting_90_1_2004,88,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -exercise_area_lighting,level_3_lighting_90_1_2004,85,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -exhibit_lighting,level_3_lighting_90_1_2004,108,default,431,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -guest_room_lighting,level_3_lighting_90_1_2004,99,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -imaging_lighting,level_3_lighting_90_1_2004,97,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -interior_parking_lighting,level_3_lighting_90_1_2004,110,default,54,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -judges_chambers_lighting,level_3_lighting_90_1_2004,81,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -food_preparation_lighting,level_3_lighting_90_1_2004,61,default,538,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -laboratory_lighting,level_3_lighting_90_1_2004,64,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -laundry_washing_lighting,level_3_lighting_90_1_2004,89,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -library_lighting,level_3_lighting_90_1_2004,13,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -living_quarters_lighting,level_3_lighting_90_1_2004,82,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -loading_dock_lighting,level_3_lighting_90_1_2004,30,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lobby_lighting,level_3_lighting_90_1_2004,68,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -locker_room_lighting,level_3_lighting_90_1_2004,59,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lounge_breakroom_lighting,level_3_lighting_90_1_2004,70,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_lighting,level_3_lighting_90_1_2004,14,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -medical_supply_lighting,level_3_lighting_90_1_2004,90,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -multifamily_lighting,level_3_lighting_90_1_2004,17,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -nursery_lighting,level_3_lighting_90_1_2004,92,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -nurses_station_lighting,level_3_lighting_90_1_2004,91,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -office_lighting,level_3_lighting_90_1_2004,19,default,414,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -office_enclosed_lighting,level_3_lighting_90_1_2004,71,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -operating_room_lighting,level_3_lighting_90_1_2004,93,default,1184,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -patient_room_lighting,level_3_lighting_90_1_2004,94,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -pharmacy_lighting,level_3_lighting_90_1_2004,95,default,888,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -physical_therapy_lighting,level_3_lighting_90_1_2004,96,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -playing_area_lighting,level_3_lighting_90_1_2004,86,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -post_office_lighting,level_3_lighting_90_1_2004,24,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -recovery_lighting,level_3_lighting_90_1_2004,98,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -recreation_common_living_lighting,level_3_lighting_90_1_2004,70,default,323,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -restroom_lighting,level_3_lighting_90_1_2004,73,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -retail_sales_lighting,level_3_lighting_90_1_2004,117,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -sleeping_quarters_lighting,level_3_lighting_90_1_2004,84,default,59,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -sports_arena_lighting,level_3_lighting_90_1_2004,28,default,1184,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -stairwell_lighting,level_3_lighting_90_1_2004,74,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -storage_lighting,level_3_lighting_90_1_2004,34,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -transportation_lighting,level_3_lighting_90_1_2004,30,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -vehicular_maintenance_lighting,level_3_lighting_90_1_2004,76,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -workshop_lighting,level_3_lighting_90_1_2004,32,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -worship_lighting,level_3_lighting_90_1_2004,25,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_automotive_facility_lighting,level_3_lighting_90_1_2004,1,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_convention_center_lighting,level_3_lighting_90_1_2004,2,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_courthouse_lighting,level_3_lighting_90_1_2004,3,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_dining_bar_lounge_leisure_lighting,level_3_lighting_90_1_2004,4,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_dining_cafeteria_fast_food_lighting,level_3_lighting_90_1_2004,5,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_dining_family_lighting,level_3_lighting_90_1_2004,6,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_dormitory_lighting,level_3_lighting_90_1_2004,7,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_exercise_center_lighting,level_3_lighting_90_1_2004,8,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_fire_station_lighting,level_3_lighting_90_1_2004,23,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_gymnasium_lighting,level_3_lighting_90_1_2004,9,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_health-care_clinic_lighting,level_3_lighting_90_1_2004,10,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_hospital_lighting,level_3_lighting_90_1_2004,11,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_hotel_motel_lighting,level_3_lighting_90_1_2004,12,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_motion_picture_theater_lighting,level_3_lighting_90_1_2004,16,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_museum_lighting,level_3_lighting_90_1_2004,18,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_parking_garage_lighting,level_3_lighting_90_1_2004,20,default,54,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_penitentiary_lighting,level_3_lighting_90_1_2004,21,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_performing_arts_theater_lighting,level_3_lighting_90_1_2004,22,default,426,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_police_station_lighting,level_3_lighting_90_1_2004,23,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_school_university_lighting,level_3_lighting_90_1_2004,27,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_town_hall_lighting,level_3_lighting_90_1_2004,29,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_retail_lighting,level_3_lighting_90_1_2004,26,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_warehouse_lighting,level_3_lighting_90_1_2004,31,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_gymnasium_lighting,level_3_lighting_90_1_2004,39,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_motion_picture_theater_lighting,level_3_lighting_90_1_2004,40,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_penitentiary_lighting,level_3_lighting_90_1_2004,41,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_performing_arts_theater_lighting,level_3_lighting_90_1_2004,42,default,426,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_religious_buildings_lighting,level_3_lighting_90_1_2004,43,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_sports_arena_lighting,level_3_lighting_90_1_2004,44,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -classroom_lecture_training_for_penitentiary_lighting,level_3_lighting_90_1_2004,47,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -corridor_transition_for_hospital_lighting,level_3_lighting_90_1_2004,50,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_area_for_penitentiary_lighting,level_3_lighting_90_1_2004,57,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_bar_lounge_leisure_general_lighting,level_3_lighting_90_1_2004,4,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_cafeteria_fast_food_general_lighting,level_3_lighting_90_1_2004,5,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_area_for_family_dining_lighting,level_3_lighting_90_1_2004,54,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lobby_for_hotel_lighting,level_3_lighting_90_1_2004,65,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lobby_for_motion_picture_theater_lighting,level_3_lighting_90_1_2004,66,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lobby_for_performing_arts_theater_lighting,level_3_lighting_90_1_2004,67,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lounge_recreation_for_hospital_lighting,level_3_lighting_90_1_2004,69,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -office-enclosed_general_lighting,level_3_lighting_90_1_2004,71,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -office_open_plan_lighting,level_3_lighting_90_1_2004,72,default,414,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -automotive_general_lighting,level_3_lighting_90_1_2004,76,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -convention_center_exhibit_space_general_lighting,level_3_lighting_90_1_2004,78,default,431,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -library_reading_area_lighting,level_3_lighting_90_1_2004,101,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -library_stacks_lighting,level_3_lighting_90_1_2004,102,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_facility_detailed_manufacturing_area_lighting,level_3_lighting_90_1_2004,104,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_facility_equipment_room_lighting,level_3_lighting_90_1_2004,105,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting,level_3_lighting_90_1_2004,106,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting,level_3_lighting_90_1_2004,107,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -museum_restoration_room_lighting,level_3_lighting_90_1_2004,109,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -post_office_sorting_area_general_lighting,level_3_lighting_90_1_2004,111,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -religious_buildings_fellowship_hall_lighting,level_3_lighting_90_1_2004,112,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -religious_buildings_worship_pulpit_choir_lighting,level_3_lighting_90_1_2004,113,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -retail_mall_concourse_lighting,level_3_lighting_90_1_2004,114,default,403,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -transportation_facility_ticket_counter_lighting,level_3_lighting_90_1_2004,123,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -warehouse_storage_area_medium_to_bulky_palletized_items_lighting,level_3_lighting_90_1_2004,125,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -warehouse_storage_area_smaller_hand-carried_items_lighting,level_3_lighting_90_1_2004,124,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -airport_concourse_lighting,level_3_lighting_90_1_2007,125,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -atrium_lighting,level_3_lighting_90_1_2007,36,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -none_lighting,level_3_lighting_90_1_2007,129,default,0,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_lighting,level_3_lighting_90_1_2007,46,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -baggage_carousel_lighting,level_3_lighting_90_1_2007,124,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -banking_lighting,level_3_lighting_90_1_2007,78,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -classroom_lecture_training_lighting,level_3_lighting_90_1_2007,48,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -computer_room_lighting,level_3_lighting_90_1_2007,48,default,710,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -conference_meeting_multipurpose_lighting,level_3_lighting_90_1_2007,49,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -confinement_cells_lighting,level_3_lighting_90_1_2007,80,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -copy_print_lighting,level_3_lighting_90_1_2007,49,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -corridor_lighting,level_3_lighting_90_1_2007,52,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -courtroom_lighting,level_3_lighting_90_1_2007,81,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -datacenterhighite_lighting,level_3_lighting_90_1_2007,60,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -datacenterlowite_lighting,level_3_lighting_90_1_2007,60,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_lighting,level_3_lighting_90_1_2007,58,default,308,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dressing_room_lighting,level_3_lighting_90_1_2007,59,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -electrical_mechanical_lighting,level_3_lighting_90_1_2007,60,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -emergency_room_lighting,level_3_lighting_90_1_2007,88,default,888,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -emergency_vehicle_garage_lighting,level_3_lighting_90_1_2007,84,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -exam_treatment_lighting,level_3_lighting_90_1_2007,89,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -exercise_area_lighting,level_3_lighting_90_1_2007,86,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -exhibit_lighting,level_3_lighting_90_1_2007,109,default,431,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -guest_room_lighting,level_3_lighting_90_1_2007,100,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -imaging_lighting,level_3_lighting_90_1_2007,98,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -interior_parking_lighting,level_3_lighting_90_1_2007,111,default,54,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -judges_chambers_lighting,level_3_lighting_90_1_2007,82,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -food_preparation_lighting,level_3_lighting_90_1_2007,61,default,538,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -laboratory_lighting,level_3_lighting_90_1_2007,64,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -laundry_washing_lighting,level_3_lighting_90_1_2007,90,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -library_lighting,level_3_lighting_90_1_2007,13,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -living_quarters_lighting,level_3_lighting_90_1_2007,83,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -loading_dock_lighting,level_3_lighting_90_1_2007,30,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lobby_lighting,level_3_lighting_90_1_2007,68,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -locker_room_lighting,level_3_lighting_90_1_2007,59,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lounge_breakroom_lighting,level_3_lighting_90_1_2007,70,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_lighting,level_3_lighting_90_1_2007,14,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -medical_supply_lighting,level_3_lighting_90_1_2007,91,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -multifamily_lighting,level_3_lighting_90_1_2007,17,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -nursery_lighting,level_3_lighting_90_1_2007,93,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -nurses_station_lighting,level_3_lighting_90_1_2007,92,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -office_lighting,level_3_lighting_90_1_2007,19,default,414,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -office_enclosed_lighting,level_3_lighting_90_1_2007,71,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -operating_room_lighting,level_3_lighting_90_1_2007,94,default,1184,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -patient_room_lighting,level_3_lighting_90_1_2007,95,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -pharmacy_lighting,level_3_lighting_90_1_2007,96,default,888,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -physical_therapy_lighting,level_3_lighting_90_1_2007,97,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -playing_area_lighting,level_3_lighting_90_1_2007,87,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -post_office_lighting,level_3_lighting_90_1_2007,24,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -recovery_lighting,level_3_lighting_90_1_2007,99,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -recreation_common_living_lighting,level_3_lighting_90_1_2007,70,default,323,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -restroom_lighting,level_3_lighting_90_1_2007,73,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -retail_sales_lighting,level_3_lighting_90_1_2007,120,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -sleeping_quarters_lighting,level_3_lighting_90_1_2007,85,default,59,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -sports_arena_lighting,level_3_lighting_90_1_2007,28,default,1184,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -stairwell_lighting,level_3_lighting_90_1_2007,75,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -storage_lighting,level_3_lighting_90_1_2007,34,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -transportation_lighting,level_3_lighting_90_1_2007,30,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -vehicular_maintenance_lighting,level_3_lighting_90_1_2007,77,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -workshop_lighting,level_3_lighting_90_1_2007,32,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -worship_lighting,level_3_lighting_90_1_2007,25,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_automotive_facility_lighting,level_3_lighting_90_1_2007,1,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_convention_center_lighting,level_3_lighting_90_1_2007,2,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_courthouse_lighting,level_3_lighting_90_1_2007,3,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_dining_bar_lounge_leisure_lighting,level_3_lighting_90_1_2007,4,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_dining_cafeteria_fast_food_lighting,level_3_lighting_90_1_2007,5,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_dining_family_lighting,level_3_lighting_90_1_2007,6,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_dormitory_lighting,level_3_lighting_90_1_2007,7,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_exercise_center_lighting,level_3_lighting_90_1_2007,8,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_fire_station_lighting,level_3_lighting_90_1_2007,23,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_gymnasium_lighting,level_3_lighting_90_1_2007,9,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_health-care_clinic_lighting,level_3_lighting_90_1_2007,10,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_hospital_lighting,level_3_lighting_90_1_2007,11,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_hotel_motel_lighting,level_3_lighting_90_1_2007,12,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_motion_picture_theater_lighting,level_3_lighting_90_1_2007,16,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_museum_lighting,level_3_lighting_90_1_2007,18,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_parking_garage_lighting,level_3_lighting_90_1_2007,20,default,54,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_penitentiary_lighting,level_3_lighting_90_1_2007,21,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_performing_arts_theater_lighting,level_3_lighting_90_1_2007,22,default,426,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_police_station_lighting,level_3_lighting_90_1_2007,23,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_school_university_lighting,level_3_lighting_90_1_2007,27,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_town_hall_lighting,level_3_lighting_90_1_2007,29,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_retail_lighting,level_3_lighting_90_1_2007,26,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_warehouse_lighting,level_3_lighting_90_1_2007,31,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_gymnasium_lighting,level_3_lighting_90_1_2007,39,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_motion_picture_theater_lighting,level_3_lighting_90_1_2007,40,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_penitentiary_lighting,level_3_lighting_90_1_2007,41,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_performing_arts_theater_lighting,level_3_lighting_90_1_2007,42,default,426,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_religious_buildings_lighting,level_3_lighting_90_1_2007,43,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_sports_arena_lighting,level_3_lighting_90_1_2007,44,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -classroom_lecture_training_for_penitentiary_lighting,level_3_lighting_90_1_2007,47,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -corridor_transition_for_hospital_lighting,level_3_lighting_90_1_2007,50,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_area_for_penitentiary_lighting,level_3_lighting_90_1_2007,57,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_bar_lounge_leisure_general_lighting,level_3_lighting_90_1_2007,4,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_cafeteria_fast_food_general_lighting,level_3_lighting_90_1_2007,5,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_area_for_family_dining_lighting,level_3_lighting_90_1_2007,54,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lobby_for_hotel_lighting,level_3_lighting_90_1_2007,65,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lobby_for_motion_picture_theater_lighting,level_3_lighting_90_1_2007,66,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lobby_for_performing_arts_theater_lighting,level_3_lighting_90_1_2007,67,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lounge_recreation_for_hospital_lighting,level_3_lighting_90_1_2007,69,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -office-enclosed_general_lighting,level_3_lighting_90_1_2007,71,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -office_open_plan_lighting,level_3_lighting_90_1_2007,72,default,414,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -automotive_general_lighting,level_3_lighting_90_1_2007,77,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -convention_center_exhibit_space_general_lighting,level_3_lighting_90_1_2007,79,default,431,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -library_reading_area_lighting,level_3_lighting_90_1_2007,102,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -library_stacks_lighting,level_3_lighting_90_1_2007,103,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_facility_detailed_manufacturing_area_lighting,level_3_lighting_90_1_2007,105,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_facility_equipment_room_lighting,level_3_lighting_90_1_2007,106,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting,level_3_lighting_90_1_2007,107,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting,level_3_lighting_90_1_2007,108,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -museum_restoration_room_lighting,level_3_lighting_90_1_2007,110,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -post_office_sorting_area_general_lighting,level_3_lighting_90_1_2007,112,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -religious_buildings_fellowship_hall_lighting,level_3_lighting_90_1_2007,113,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -religious_buildings_worship_pulpit_choir_lighting,level_3_lighting_90_1_2007,114,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -retail_mall_concourse_lighting,level_3_lighting_90_1_2007,115,default,403,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -transportation_facility_ticket_counter_lighting,level_3_lighting_90_1_2007,126,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -warehouse_storage_area_medium_to_bulky_palletized_items_lighting,level_3_lighting_90_1_2007,128,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -warehouse_storage_area_smaller_hand-carried_items_lighting,level_3_lighting_90_1_2007,127,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -airport_concourse_lighting,level_3_lighting_90_1_2010,128,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -atrium_lighting,level_3_lighting_90_1_2010,34,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -none_lighting,level_3_lighting_90_1_2010,133,default,0,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_lighting,level_3_lighting_90_1_2010,36,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -baggage_carousel_lighting,level_3_lighting_90_1_2010,127,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -banking_lighting,level_3_lighting_90_1_2010,64,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -classroom_lecture_training_lighting,level_3_lighting_90_1_2010,39,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -computer_room_lighting,level_3_lighting_90_1_2010,39,default,710,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -conference_meeting_multipurpose_lighting,level_3_lighting_90_1_2010,40,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -confinement_cells_lighting,level_3_lighting_90_1_2010,67,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -copy_print_lighting,level_3_lighting_90_1_2010,40,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -corridor_lighting,level_3_lighting_90_1_2010,41,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -courtroom_lighting,level_3_lighting_90_1_2010,68,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -datacenterhighite_lighting,level_3_lighting_90_1_2010,46,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -datacenterlowite_lighting,level_3_lighting_90_1_2010,46,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_lighting,level_3_lighting_90_1_2010,44,default,308,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dressing_room_lighting,level_3_lighting_90_1_2010,113,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -electrical_mechanical_lighting,level_3_lighting_90_1_2010,46,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -emergency_room_lighting,level_3_lighting_90_1_2010,80,default,888,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -emergency_vehicle_garage_lighting,level_3_lighting_90_1_2010,74,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -exam_treatment_lighting,level_3_lighting_90_1_2010,81,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -exercise_area_lighting,level_3_lighting_90_1_2010,76,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -exhibit_lighting,level_3_lighting_90_1_2010,107,default,431,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -guest_room_lighting,level_3_lighting_90_1_2010,96,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -imaging_lighting,level_3_lighting_90_1_2010,91,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -interior_parking_lighting,level_3_lighting_90_1_2010,109,default,54,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -judges_chambers_lighting,level_3_lighting_90_1_2010,69,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -food_preparation_lighting,level_3_lighting_90_1_2010,47,default,538,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -laboratory_lighting,level_3_lighting_90_1_2010,49,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -laundry_washing_lighting,level_3_lighting_90_1_2010,82,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -library_lighting,level_3_lighting_90_1_2010,14,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -living_quarters_lighting,level_3_lighting_90_1_2010,73,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -loading_dock_lighting,level_3_lighting_90_1_2010,31,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lobby_lighting,level_3_lighting_90_1_2010,53,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -locker_room_lighting,level_3_lighting_90_1_2010,54,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lounge_breakroom_lighting,level_3_lighting_90_1_2010,55,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_lighting,level_3_lighting_90_1_2010,15,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -medical_supply_lighting,level_3_lighting_90_1_2010,84,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -multifamily_lighting,level_3_lighting_90_1_2010,18,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -nursery_lighting,level_3_lighting_90_1_2010,85,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -nurses_station_lighting,level_3_lighting_90_1_2010,86,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -office_lighting,level_3_lighting_90_1_2010,20,default,414,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -office_enclosed_lighting,level_3_lighting_90_1_2010,56,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -operating_room_lighting,level_3_lighting_90_1_2010,87,default,1184,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -patient_room_lighting,level_3_lighting_90_1_2010,88,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -pharmacy_lighting,level_3_lighting_90_1_2010,89,default,888,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -physical_therapy_lighting,level_3_lighting_90_1_2010,90,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -playing_area_lighting,level_3_lighting_90_1_2010,78,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -post_office_lighting,level_3_lighting_90_1_2010,25,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -recovery_lighting,level_3_lighting_90_1_2010,92,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -recreation_common_living_lighting,level_3_lighting_90_1_2010,55,default,323,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -restroom_lighting,level_3_lighting_90_1_2010,58,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -retail_sales_lighting,level_3_lighting_90_1_2010,119,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -sleeping_quarters_lighting,level_3_lighting_90_1_2010,75,default,59,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -sports_arena_lighting,level_3_lighting_90_1_2010,29,default,1184,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -stairwell_lighting,level_3_lighting_90_1_2010,60,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -storage_lighting,level_3_lighting_90_1_2010,61,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -transportation_lighting,level_3_lighting_90_1_2010,31,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -vehicular_maintenance_lighting,level_3_lighting_90_1_2010,63,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -workshop_lighting,level_3_lighting_90_1_2010,33,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -worship_lighting,level_3_lighting_90_1_2010,26,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_automotive_facility_lighting,level_3_lighting_90_1_2010,1,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_convention_center_lighting,level_3_lighting_90_1_2010,2,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_courthouse_lighting,level_3_lighting_90_1_2010,3,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_dining_bar_lounge_leisure_lighting,level_3_lighting_90_1_2010,4,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_dining_cafeteria_fast_food_lighting,level_3_lighting_90_1_2010,5,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_dining_family_lighting,level_3_lighting_90_1_2010,6,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_dormitory_lighting,level_3_lighting_90_1_2010,7,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_exercise_center_lighting,level_3_lighting_90_1_2010,8,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_fire_station_lighting,level_3_lighting_90_1_2010,9,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_gymnasium_lighting,level_3_lighting_90_1_2010,10,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_health-care_clinic_lighting,level_3_lighting_90_1_2010,11,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_hospital_lighting,level_3_lighting_90_1_2010,12,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_hotel_motel_lighting,level_3_lighting_90_1_2010,13,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_motion_picture_theater_lighting,level_3_lighting_90_1_2010,17,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_museum_lighting,level_3_lighting_90_1_2010,19,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_parking_garage_lighting,level_3_lighting_90_1_2010,21,default,54,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_penitentiary_lighting,level_3_lighting_90_1_2010,22,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_performing_arts_theater_lighting,level_3_lighting_90_1_2010,23,default,426,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_police_station_lighting,level_3_lighting_90_1_2010,24,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_school_university_lighting,level_3_lighting_90_1_2010,28,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_town_hall_lighting,level_3_lighting_90_1_2010,30,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_retail_lighting,level_3_lighting_90_1_2010,27,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_warehouse_lighting,level_3_lighting_90_1_2010,32,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_gymnasium_lighting,level_3_lighting_90_1_2010,77,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_motion_picture_theater_lighting,level_3_lighting_90_1_2010,37,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_penitentiary_lighting,level_3_lighting_90_1_2010,70,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_performing_arts_theater_lighting,level_3_lighting_90_1_2010,38,default,426,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_religious_buildings_lighting,level_3_lighting_90_1_2010,110,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_sports_arena_lighting,level_3_lighting_90_1_2010,120,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -classroom_lecture_training_for_penitentiary_lighting,level_3_lighting_90_1_2010,71,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -corridor_transition_for_hospital_lighting,level_3_lighting_90_1_2010,79,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_area_for_penitentiary_lighting,level_3_lighting_90_1_2010,72,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_bar_lounge_leisure_general_lighting,level_3_lighting_90_1_2010,4,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_cafeteria_fast_food_general_lighting,level_3_lighting_90_1_2010,5,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_area_for_family_dining_lighting,level_3_lighting_90_1_2010,43,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lobby_for_hotel_lighting,level_3_lighting_90_1_2010,97,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lobby_for_motion_picture_theater_lighting,level_3_lighting_90_1_2010,51,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lobby_for_performing_arts_theater_lighting,level_3_lighting_90_1_2010,52,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lounge_recreation_for_hospital_lighting,level_3_lighting_90_1_2010,83,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -office-enclosed_general_lighting,level_3_lighting_90_1_2010,56,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -office_open_plan_lighting,level_3_lighting_90_1_2010,57,default,414,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -automotive_general_lighting,level_3_lighting_90_1_2010,63,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -convention_center_exhibit_space_general_lighting,level_3_lighting_90_1_2010,66,default,431,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -library_reading_area_lighting,level_3_lighting_90_1_2010,99,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -library_stacks_lighting,level_3_lighting_90_1_2010,100,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_facility_detailed_manufacturing_area_lighting,level_3_lighting_90_1_2010,102,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_facility_equipment_room_lighting,level_3_lighting_90_1_2010,103,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting,level_3_lighting_90_1_2010,105,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting,level_3_lighting_90_1_2010,106,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -museum_restoration_room_lighting,level_3_lighting_90_1_2010,108,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -post_office_sorting_area_general_lighting,level_3_lighting_90_1_2010,126,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -religious_buildings_fellowship_hall_lighting,level_3_lighting_90_1_2010,111,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -religious_buildings_worship_pulpit_choir_lighting,level_3_lighting_90_1_2010,112,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -retail_mall_concourse_lighting,level_3_lighting_90_1_2010,114,default,403,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -transportation_facility_ticket_counter_lighting,level_3_lighting_90_1_2010,130,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -warehouse_storage_area_medium_to_bulky_palletized_items_lighting,level_3_lighting_90_1_2010,132,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -warehouse_storage_area_smaller_hand-carried_items_lighting,level_3_lighting_90_1_2010,131,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -airport_concourse_lighting,level_3_lighting_90_1_2013,140,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -atrium_lighting,level_3_lighting_90_1_2013,33,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -none_lighting,level_3_lighting_90_1_2013,143,default,0,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_lighting,level_3_lighting_90_1_2013,36,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -baggage_carousel_lighting,level_3_lighting_90_1_2013,139,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -banking_lighting,level_3_lighting_90_1_2013,45,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -classroom_lecture_training_lighting,level_3_lighting_90_1_2013,47,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -computer_room_lighting,level_3_lighting_90_1_2013,49,default,710,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -conference_meeting_multipurpose_lighting,level_3_lighting_90_1_2013,50,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -confinement_cells_lighting,level_3_lighting_90_1_2013,51,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -copy_print_lighting,level_3_lighting_90_1_2013,52,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -corridor_lighting,level_3_lighting_90_1_2013,53,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -courtroom_lighting,level_3_lighting_90_1_2013,57,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -datacenterhighite_lighting,level_3_lighting_90_1_2013,64,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -datacenterlowite_lighting,level_3_lighting_90_1_2013,64,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_lighting,level_3_lighting_90_1_2013,58,default,308,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dressing_room_lighting,level_3_lighting_90_1_2013,128,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -electrical_mechanical_lighting,level_3_lighting_90_1_2013,64,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -emergency_room_lighting,level_3_lighting_90_1_2013,112,default,888,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -emergency_vehicle_garage_lighting,level_3_lighting_90_1_2013,65,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -exam_treatment_lighting,level_3_lighting_90_1_2013,112,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -exercise_area_lighting,level_3_lighting_90_1_2013,105,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -exhibit_lighting,level_3_lighting_90_1_2013,122,default,431,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -guest_room_lighting,level_3_lighting_90_1_2013,67,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -imaging_lighting,level_3_lighting_90_1_2013,113,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -interior_parking_lighting,level_3_lighting_90_1_2013,84,default,54,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -judges_chambers_lighting,level_3_lighting_90_1_2013,57,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -food_preparation_lighting,level_3_lighting_90_1_2013,66,default,538,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -laboratory_lighting,level_3_lighting_90_1_2013,68,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -laundry_washing_lighting,level_3_lighting_90_1_2013,70,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -library_lighting,level_3_lighting_90_1_2013,14,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -living_quarters_lighting,level_3_lighting_90_1_2013,99,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -loading_dock_lighting,level_3_lighting_90_1_2013,71,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lobby_lighting,level_3_lighting_90_1_2013,72,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -locker_room_lighting,level_3_lighting_90_1_2013,78,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lounge_breakroom_lighting,level_3_lighting_90_1_2013,46,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_lighting,level_3_lighting_90_1_2013,15,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -medical_supply_lighting,level_3_lighting_90_1_2013,106,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -multifamily_lighting,level_3_lighting_90_1_2013,17,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -nursery_lighting,level_3_lighting_90_1_2013,108,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -nurses_station_lighting,level_3_lighting_90_1_2013,107,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -office_lighting,level_3_lighting_90_1_2013,19,default,414,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -office_enclosed_lighting,level_3_lighting_90_1_2013,81,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -operating_room_lighting,level_3_lighting_90_1_2013,114,default,1184,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -patient_room_lighting,level_3_lighting_90_1_2013,109,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -pharmacy_lighting,level_3_lighting_90_1_2013,106,default,888,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -physical_therapy_lighting,level_3_lighting_90_1_2013,110,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -playing_area_lighting,level_3_lighting_90_1_2013,104,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -post_office_lighting,level_3_lighting_90_1_2013,24,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -recovery_lighting,level_3_lighting_90_1_2013,111,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -recreation_common_living_lighting,level_3_lighting_90_1_2013,79,default,323,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -restroom_lighting,level_3_lighting_90_1_2013,86,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -retail_sales_lighting,level_3_lighting_90_1_2013,88,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -sleeping_quarters_lighting,level_3_lighting_90_1_2013,103,default,59,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -sports_arena_lighting,level_3_lighting_90_1_2013,28,default,1184,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -stairwell_lighting,level_3_lighting_90_1_2013,91,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -storage_lighting,level_3_lighting_90_1_2013,94,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -transportation_lighting,level_3_lighting_90_1_2013,30,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -vehicular_maintenance_lighting,level_3_lighting_90_1_2013,95,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -workshop_lighting,level_3_lighting_90_1_2013,32,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -worship_lighting,level_3_lighting_90_1_2013,25,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_automotive_facility_lighting,level_3_lighting_90_1_2013,1,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_convention_center_lighting,level_3_lighting_90_1_2013,2,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_courthouse_lighting,level_3_lighting_90_1_2013,3,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_dining_bar_lounge_leisure_lighting,level_3_lighting_90_1_2013,4,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_dining_cafeteria_fast_food_lighting,level_3_lighting_90_1_2013,5,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_dining_family_lighting,level_3_lighting_90_1_2013,6,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_dormitory_lighting,level_3_lighting_90_1_2013,7,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_exercise_center_lighting,level_3_lighting_90_1_2013,8,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_fire_station_lighting,level_3_lighting_90_1_2013,9,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_gymnasium_lighting,level_3_lighting_90_1_2013,10,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_health-care_clinic_lighting,level_3_lighting_90_1_2013,11,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_hospital_lighting,level_3_lighting_90_1_2013,12,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_hotel_motel_lighting,level_3_lighting_90_1_2013,13,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_motion_picture_theater_lighting,level_3_lighting_90_1_2013,16,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_museum_lighting,level_3_lighting_90_1_2013,18,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_parking_garage_lighting,level_3_lighting_90_1_2013,20,default,54,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_penitentiary_lighting,level_3_lighting_90_1_2013,21,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_performing_arts_theater_lighting,level_3_lighting_90_1_2013,22,default,426,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_police_station_lighting,level_3_lighting_90_1_2013,23,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_school_university_lighting,level_3_lighting_90_1_2013,27,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_town_hall_lighting,level_3_lighting_90_1_2013,29,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_retail_lighting,level_3_lighting_90_1_2013,26,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_warehouse_lighting,level_3_lighting_90_1_2013,31,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_gymnasium_lighting,level_3_lighting_90_1_2013,38,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_motion_picture_theater_lighting,level_3_lighting_90_1_2013,39,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_penitentiary_lighting,level_3_lighting_90_1_2013,40,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_performing_arts_theater_lighting,level_3_lighting_90_1_2013,41,default,426,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_religious_buildings_lighting,level_3_lighting_90_1_2013,42,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_sports_arena_lighting,level_3_lighting_90_1_2013,43,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -classroom_lecture_training_for_penitentiary_lighting,level_3_lighting_90_1_2013,48,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -corridor_transition_for_hospital_lighting,level_3_lighting_90_1_2013,55,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_area_for_penitentiary_lighting,level_3_lighting_90_1_2013,60,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_bar_lounge_leisure_general_lighting,level_3_lighting_90_1_2013,4,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_cafeteria_fast_food_general_lighting,level_3_lighting_90_1_2013,5,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_area_for_family_dining_lighting,level_3_lighting_90_1_2013,63,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lobby_for_hotel_lighting,level_3_lighting_90_1_2013,75,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lobby_for_motion_picture_theater_lighting,level_3_lighting_90_1_2013,76,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lobby_for_performing_arts_theater_lighting,level_3_lighting_90_1_2013,77,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lounge_recreation_for_hospital_lighting,level_3_lighting_90_1_2013,80,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -office-enclosed_general_lighting,level_3_lighting_90_1_2013,81,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -office_open_plan_lighting,level_3_lighting_90_1_2013,83,default,414,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -automotive_general_lighting,level_3_lighting_90_1_2013,97,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -convention_center_exhibit_space_general_lighting,level_3_lighting_90_1_2013,98,default,431,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -library_reading_area_lighting,level_3_lighting_90_1_2013,115,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -library_stacks_lighting,level_3_lighting_90_1_2013,116,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_facility_detailed_manufacturing_area_lighting,level_3_lighting_90_1_2013,117,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_facility_equipment_room_lighting,level_3_lighting_90_1_2013,120,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting,level_3_lighting_90_1_2013,118,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting,level_3_lighting_90_1_2013,119,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -museum_restoration_room_lighting,level_3_lighting_90_1_2013,123,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -post_office_sorting_area_general_lighting,level_3_lighting_90_1_2013,125,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -religious_buildings_fellowship_hall_lighting,level_3_lighting_90_1_2013,127,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -religious_buildings_worship_pulpit_choir_lighting,level_3_lighting_90_1_2013,126,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -retail_mall_concourse_lighting,level_3_lighting_90_1_2013,129,default,403,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -transportation_facility_ticket_counter_lighting,level_3_lighting_90_1_2013,138,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -warehouse_storage_area_medium_to_bulky_palletized_items_lighting,level_3_lighting_90_1_2013,141,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -warehouse_storage_area_smaller_hand-carried_items_lighting,level_3_lighting_90_1_2013,142,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -airport_concourse_lighting,level_3_lighting_90_1_2016,137,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -atrium_lighting,level_3_lighting_90_1_2016,33,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -none_lighting,level_3_lighting_90_1_2016,142,default,0,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_lighting,level_3_lighting_90_1_2016,36,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -baggage_carousel_lighting,level_3_lighting_90_1_2016,138,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -banking_lighting,level_3_lighting_90_1_2016,45,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -classroom_lecture_training_lighting,level_3_lighting_90_1_2016,47,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -computer_room_lighting,level_3_lighting_90_1_2016,49,default,710,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -conference_meeting_multipurpose_lighting,level_3_lighting_90_1_2016,50,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -confinement_cells_lighting,level_3_lighting_90_1_2016,51,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -copy_print_lighting,level_3_lighting_90_1_2016,52,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -corridor_lighting,level_3_lighting_90_1_2016,53,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -courtroom_lighting,level_3_lighting_90_1_2016,57,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -datacenterhighite_lighting,level_3_lighting_90_1_2016,64,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -datacenterlowite_lighting,level_3_lighting_90_1_2016,64,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_lighting,level_3_lighting_90_1_2016,58,default,308,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dressing_room_lighting,level_3_lighting_90_1_2016,127,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -electrical_mechanical_lighting,level_3_lighting_90_1_2016,64,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -emergency_room_lighting,level_3_lighting_90_1_2016,105,default,888,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -emergency_vehicle_garage_lighting,level_3_lighting_90_1_2016,65,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -exam_treatment_lighting,level_3_lighting_90_1_2016,105,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -exercise_area_lighting,level_3_lighting_90_1_2016,103,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -exhibit_lighting,level_3_lighting_90_1_2016,121,default,431,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -guest_room_lighting,level_3_lighting_90_1_2016,67,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -imaging_lighting,level_3_lighting_90_1_2016,106,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -interior_parking_lighting,level_3_lighting_90_1_2016,84,default,54,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -judges_chambers_lighting,level_3_lighting_90_1_2016,57,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -food_preparation_lighting,level_3_lighting_90_1_2016,66,default,538,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -laboratory_lighting,level_3_lighting_90_1_2016,68,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -laundry_washing_lighting,level_3_lighting_90_1_2016,70,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -library_lighting,level_3_lighting_90_1_2016,14,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -living_quarters_lighting,level_3_lighting_90_1_2016,99,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -loading_dock_lighting,level_3_lighting_90_1_2016,71,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lobby_lighting,level_3_lighting_90_1_2016,72,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -locker_room_lighting,level_3_lighting_90_1_2016,78,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lounge_breakroom_lighting,level_3_lighting_90_1_2016,46,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_lighting,level_3_lighting_90_1_2016,15,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -medical_supply_lighting,level_3_lighting_90_1_2016,107,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -multifamily_lighting,level_3_lighting_90_1_2016,17,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -nursery_lighting,level_3_lighting_90_1_2016,109,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -nurses_station_lighting,level_3_lighting_90_1_2016,108,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -office_lighting,level_3_lighting_90_1_2016,19,default,414,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -office_enclosed_lighting,level_3_lighting_90_1_2016,81,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -operating_room_lighting,level_3_lighting_90_1_2016,110,default,1184,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -patient_room_lighting,level_3_lighting_90_1_2016,111,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -pharmacy_lighting,level_3_lighting_90_1_2016,107,default,888,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -physical_therapy_lighting,level_3_lighting_90_1_2016,112,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -playing_area_lighting,level_3_lighting_90_1_2016,104,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -post_office_lighting,level_3_lighting_90_1_2016,24,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -recovery_lighting,level_3_lighting_90_1_2016,113,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -recreation_common_living_lighting,level_3_lighting_90_1_2016,79,default,323,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -restroom_lighting,level_3_lighting_90_1_2016,86,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -retail_sales_lighting,level_3_lighting_90_1_2016,88,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -sleeping_quarters_lighting,level_3_lighting_90_1_2016,102,default,59,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -sports_arena_lighting,level_3_lighting_90_1_2016,28,default,1184,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -stairwell_lighting,level_3_lighting_90_1_2016,91,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -storage_lighting,level_3_lighting_90_1_2016,94,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -transportation_lighting,level_3_lighting_90_1_2016,30,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -vehicular_maintenance_lighting,level_3_lighting_90_1_2016,95,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -workshop_lighting,level_3_lighting_90_1_2016,32,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -worship_lighting,level_3_lighting_90_1_2016,25,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_automotive_facility_lighting,level_3_lighting_90_1_2016,1,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_convention_center_lighting,level_3_lighting_90_1_2016,2,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_courthouse_lighting,level_3_lighting_90_1_2016,3,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_dining_bar_lounge_leisure_lighting,level_3_lighting_90_1_2016,4,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_dining_cafeteria_fast_food_lighting,level_3_lighting_90_1_2016,5,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_dining_family_lighting,level_3_lighting_90_1_2016,6,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_dormitory_lighting,level_3_lighting_90_1_2016,7,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_exercise_center_lighting,level_3_lighting_90_1_2016,8,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_fire_station_lighting,level_3_lighting_90_1_2016,9,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_gymnasium_lighting,level_3_lighting_90_1_2016,10,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_health-care_clinic_lighting,level_3_lighting_90_1_2016,11,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_hospital_lighting,level_3_lighting_90_1_2016,12,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_hotel_motel_lighting,level_3_lighting_90_1_2016,13,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_motion_picture_theater_lighting,level_3_lighting_90_1_2016,16,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_museum_lighting,level_3_lighting_90_1_2016,18,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_parking_garage_lighting,level_3_lighting_90_1_2016,20,default,54,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_penitentiary_lighting,level_3_lighting_90_1_2016,21,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_performing_arts_theater_lighting,level_3_lighting_90_1_2016,22,default,426,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_police_station_lighting,level_3_lighting_90_1_2016,23,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_school_university_lighting,level_3_lighting_90_1_2016,27,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_town_hall_lighting,level_3_lighting_90_1_2016,29,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_retail_lighting,level_3_lighting_90_1_2016,26,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_warehouse_lighting,level_3_lighting_90_1_2016,31,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_gymnasium_lighting,level_3_lighting_90_1_2016,39,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_motion_picture_theater_lighting,level_3_lighting_90_1_2016,40,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_penitentiary_lighting,level_3_lighting_90_1_2016,41,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_performing_arts_theater_lighting,level_3_lighting_90_1_2016,42,default,426,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_religious_buildings_lighting,level_3_lighting_90_1_2016,43,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_sports_arena_lighting,level_3_lighting_90_1_2016,44,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -classroom_lecture_training_for_penitentiary_lighting,level_3_lighting_90_1_2016,48,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -corridor_transition_for_hospital_lighting,level_3_lighting_90_1_2016,55,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_area_for_penitentiary_lighting,level_3_lighting_90_1_2016,61,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_bar_lounge_leisure_general_lighting,level_3_lighting_90_1_2016,4,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_cafeteria_fast_food_general_lighting,level_3_lighting_90_1_2016,5,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_area_for_family_dining_lighting,level_3_lighting_90_1_2016,62,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lobby_for_hotel_lighting,level_3_lighting_90_1_2016,75,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lobby_for_motion_picture_theater_lighting,level_3_lighting_90_1_2016,76,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lobby_for_performing_arts_theater_lighting,level_3_lighting_90_1_2016,77,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lounge_recreation_for_hospital_lighting,level_3_lighting_90_1_2016,80,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -office-enclosed_general_lighting,level_3_lighting_90_1_2016,81,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -office_open_plan_lighting,level_3_lighting_90_1_2016,83,default,414,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -automotive_general_lighting,level_3_lighting_90_1_2016,97,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -convention_center_exhibit_space_general_lighting,level_3_lighting_90_1_2016,98,default,431,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -library_reading_area_lighting,level_3_lighting_90_1_2016,114,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -library_stacks_lighting,level_3_lighting_90_1_2016,115,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_facility_detailed_manufacturing_area_lighting,level_3_lighting_90_1_2016,116,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_facility_equipment_room_lighting,level_3_lighting_90_1_2016,117,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting,level_3_lighting_90_1_2016,119,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting,level_3_lighting_90_1_2016,120,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -museum_restoration_room_lighting,level_3_lighting_90_1_2016,122,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -post_office_sorting_area_general_lighting,level_3_lighting_90_1_2016,124,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -religious_buildings_fellowship_hall_lighting,level_3_lighting_90_1_2016,125,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -religious_buildings_worship_pulpit_choir_lighting,level_3_lighting_90_1_2016,126,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -retail_mall_concourse_lighting,level_3_lighting_90_1_2016,128,default,403,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -transportation_facility_ticket_counter_lighting,level_3_lighting_90_1_2016,139,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -warehouse_storage_area_medium_to_bulky_palletized_items_lighting,level_3_lighting_90_1_2016,140,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -warehouse_storage_area_smaller_hand-carried_items_lighting,level_3_lighting_90_1_2016,141,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -airport_concourse_lighting,level_3_lighting_90_1_2019,134,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -atrium_lighting,level_3_lighting_90_1_2019,33,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -none_lighting,level_3_lighting_90_1_2019,139,default,0,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_lighting,level_3_lighting_90_1_2019,36,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -baggage_carousel_lighting,level_3_lighting_90_1_2019,135,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -banking_lighting,level_3_lighting_90_1_2019,44,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -classroom_lecture_training_lighting,level_3_lighting_90_1_2019,46,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -computer_room_lighting,level_3_lighting_90_1_2019,48,default,710,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -conference_meeting_multipurpose_lighting,level_3_lighting_90_1_2019,49,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -confinement_cells_lighting,level_3_lighting_90_1_2019,50,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -copy_print_lighting,level_3_lighting_90_1_2019,51,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -corridor_lighting,level_3_lighting_90_1_2019,52,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -courtroom_lighting,level_3_lighting_90_1_2019,55,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -datacenterhighite_lighting,level_3_lighting_90_1_2019,62,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -datacenterlowite_lighting,level_3_lighting_90_1_2019,62,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_lighting,level_3_lighting_90_1_2019,56,default,308,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dressing_room_lighting,level_3_lighting_90_1_2019,124,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -electrical_mechanical_lighting,level_3_lighting_90_1_2019,62,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -emergency_room_lighting,level_3_lighting_90_1_2019,102,default,888,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -emergency_vehicle_garage_lighting,level_3_lighting_90_1_2019,63,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -exam_treatment_lighting,level_3_lighting_90_1_2019,102,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -exercise_area_lighting,level_3_lighting_90_1_2019,100,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -exhibit_lighting,level_3_lighting_90_1_2019,118,default,431,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -guest_room_lighting,level_3_lighting_90_1_2019,65,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -imaging_lighting,level_3_lighting_90_1_2019,103,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -interior_parking_lighting,level_3_lighting_90_1_2019,82,default,54,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -judges_chambers_lighting,level_3_lighting_90_1_2019,55,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -food_preparation_lighting,level_3_lighting_90_1_2019,64,default,538,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -laboratory_lighting,level_3_lighting_90_1_2019,66,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -laundry_washing_lighting,level_3_lighting_90_1_2019,68,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -library_lighting,level_3_lighting_90_1_2019,14,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -living_quarters_lighting,level_3_lighting_90_1_2019,96,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -loading_dock_lighting,level_3_lighting_90_1_2019,69,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lobby_lighting,level_3_lighting_90_1_2019,70,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -locker_room_lighting,level_3_lighting_90_1_2019,76,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lounge_breakroom_lighting,level_3_lighting_90_1_2019,45,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_lighting,level_3_lighting_90_1_2019,15,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -medical_supply_lighting,level_3_lighting_90_1_2019,104,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -multifamily_lighting,level_3_lighting_90_1_2019,17,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -nursery_lighting,level_3_lighting_90_1_2019,105,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -nurses_station_lighting,level_3_lighting_90_1_2019,106,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -office_lighting,level_3_lighting_90_1_2019,19,default,414,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -office_enclosed_lighting,level_3_lighting_90_1_2019,79,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -operating_room_lighting,level_3_lighting_90_1_2019,107,default,1184,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -patient_room_lighting,level_3_lighting_90_1_2019,108,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -pharmacy_lighting,level_3_lighting_90_1_2019,104,default,888,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -physical_therapy_lighting,level_3_lighting_90_1_2019,109,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -playing_area_lighting,level_3_lighting_90_1_2019,101,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -post_office_lighting,level_3_lighting_90_1_2019,24,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -recovery_lighting,level_3_lighting_90_1_2019,110,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -recreation_common_living_lighting,level_3_lighting_90_1_2019,77,default,323,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -restroom_lighting,level_3_lighting_90_1_2019,84,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -retail_sales_lighting,level_3_lighting_90_1_2019,86,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -sleeping_quarters_lighting,level_3_lighting_90_1_2019,99,default,59,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -sports_arena_lighting,level_3_lighting_90_1_2019,28,default,1184,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -stairwell_lighting,level_3_lighting_90_1_2019,89,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -storage_lighting,level_3_lighting_90_1_2019,91,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -transportation_lighting,level_3_lighting_90_1_2019,30,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -vehicular_maintenance_lighting,level_3_lighting_90_1_2019,92,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -workshop_lighting,level_3_lighting_90_1_2019,32,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -worship_lighting,level_3_lighting_90_1_2019,25,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_automotive_facility_lighting,level_3_lighting_90_1_2019,1,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_convention_center_lighting,level_3_lighting_90_1_2019,2,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_courthouse_lighting,level_3_lighting_90_1_2019,3,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_dining_bar_lounge_leisure_lighting,level_3_lighting_90_1_2019,4,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_dining_cafeteria_fast_food_lighting,level_3_lighting_90_1_2019,5,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_dining_family_lighting,level_3_lighting_90_1_2019,6,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_dormitory_lighting,level_3_lighting_90_1_2019,7,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_exercise_center_lighting,level_3_lighting_90_1_2019,8,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_fire_station_lighting,level_3_lighting_90_1_2019,9,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_gymnasium_lighting,level_3_lighting_90_1_2019,10,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_health-care_clinic_lighting,level_3_lighting_90_1_2019,11,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_hospital_lighting,level_3_lighting_90_1_2019,12,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_hotel_motel_lighting,level_3_lighting_90_1_2019,13,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_motion_picture_theater_lighting,level_3_lighting_90_1_2019,16,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_museum_lighting,level_3_lighting_90_1_2019,18,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_parking_garage_lighting,level_3_lighting_90_1_2019,20,default,54,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_penitentiary_lighting,level_3_lighting_90_1_2019,21,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_performing_arts_theater_lighting,level_3_lighting_90_1_2019,22,default,426,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_police_station_lighting,level_3_lighting_90_1_2019,23,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_school_university_lighting,level_3_lighting_90_1_2019,27,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_town_hall_lighting,level_3_lighting_90_1_2019,29,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_retail_lighting,level_3_lighting_90_1_2019,26,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -ba_warehouse_lighting,level_3_lighting_90_1_2019,31,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_gymnasium_lighting,level_3_lighting_90_1_2019,38,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_motion_picture_theater_lighting,level_3_lighting_90_1_2019,39,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_penitentiary_lighting,level_3_lighting_90_1_2019,40,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_performing_arts_theater_lighting,level_3_lighting_90_1_2019,41,default,426,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_religious_buildings_lighting,level_3_lighting_90_1_2019,42,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -audience_seating_area_for_sports_arena_lighting,level_3_lighting_90_1_2019,43,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -classroom_lecture_training_for_penitentiary_lighting,level_3_lighting_90_1_2019,47,default,471,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -corridor_transition_for_hospital_lighting,level_3_lighting_90_1_2019,54,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_area_for_penitentiary_lighting,level_3_lighting_90_1_2019,61,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_bar_lounge_leisure_general_lighting,level_3_lighting_90_1_2019,57,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_cafeteria_fast_food_general_lighting,level_3_lighting_90_1_2019,58,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -dining_area_for_family_dining_lighting,level_3_lighting_90_1_2019,60,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lobby_for_hotel_lighting,level_3_lighting_90_1_2019,73,default,178,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lobby_for_motion_picture_theater_lighting,level_3_lighting_90_1_2019,74,default,118,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lobby_for_performing_arts_theater_lighting,level_3_lighting_90_1_2019,75,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -lounge_recreation_for_hospital_lighting,level_3_lighting_90_1_2019,78,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -office-enclosed_general_lighting,level_3_lighting_90_1_2019,80,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -office_open_plan_lighting,level_3_lighting_90_1_2019,81,default,414,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -automotive_general_lighting,level_3_lighting_90_1_2019,94,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -convention_center_exhibit_space_general_lighting,level_3_lighting_90_1_2019,95,default,431,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -library_reading_area_lighting,level_3_lighting_90_1_2019,111,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -library_stacks_lighting,level_3_lighting_90_1_2019,112,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_facility_detailed_manufacturing_area_lighting,level_3_lighting_90_1_2019,113,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_facility_equipment_room_lighting,level_3_lighting_90_1_2019,114,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting,level_3_lighting_90_1_2019,116,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting,level_3_lighting_90_1_2019,117,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -museum_restoration_room_lighting,level_3_lighting_90_1_2019,119,default,592,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -post_office_sorting_area_general_lighting,level_3_lighting_90_1_2019,121,default,474,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -religious_buildings_fellowship_hall_lighting,level_3_lighting_90_1_2019,122,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -religious_buildings_worship_pulpit_choir_lighting,level_3_lighting_90_1_2019,123,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -retail_mall_concourse_lighting,level_3_lighting_90_1_2019,125,default,403,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -transportation_facility_ticket_counter_lighting,level_3_lighting_90_1_2019,136,default,296,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -warehouse_storage_area_medium_to_bulky_palletized_items_lighting,level_3_lighting_90_1_2019,137,default,355,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" -warehouse_storage_area_smaller_hand-carried_items_lighting,level_3_lighting_90_1_2019,138,default,237,"illuminance setpoint values have been determined based on ""2019"" on total horizontal illuminance values provided by IES" diff --git a/data/openstudio_standards_data/database_files/level_2_natural_gas_equipment.csv b/data/openstudio_standards_data/database_files/level_2_natural_gas_equipment.csv deleted file mode 100644 index ef5887559a..0000000000 --- a/data/openstudio_standards_data/database_files/level_2_natural_gas_equipment.csv +++ /dev/null @@ -1,7 +0,0 @@ -natural_gas_equipment_space_type_name,natural_gas_equipment_minimum_epd,natural_gas_equipment_average_epd,natural_gas_equipment_median_epd,natural_gas_equipment_maximum_epd,natural_gas_equipment_epd_unit,natural_gas_equipment_fraction_latent,natural_gas_equipment_fraction_radiant,natural_gas_equipment_fraction_lost -kitchen,51.16,361.7807576,302.6,767,Btu/hr.ft2,0.1,0.2,0.7 -laundry,42.6,138.4291667,129.9,170,Btu/hr.ft2,0,0.5,0 -or,17.4,23.223,23.87,23.87,Btu/hr.ft2,0,0,0.5 -deli,8.52,8.5225,8.52,8.53,Btu/hr.ft2,0.1,0.2,0.7 -bakery,8.53,8.5375,8.54,8.54,Btu/hr.ft2,0.1,0.2,0.7 -deli/bakery,6.25,6.25,6.25,6.25,Btu/hr.ft2,0.1,0.2,0.7 diff --git a/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.csv b/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.csv deleted file mode 100644 index cee4562fa1..0000000000 --- a/data/openstudio_standards_data/database_files/level_2_ventilation_space_types.csv +++ /dev/null @@ -1,526 +0,0 @@ -ventilation_space_type_name,level_3_ventilation_definition_table,level_3_ventilation_definition_id -airport_concourse_ventilation,level_3_ventilation_62_1_2019,63 -atrium_ventilation,level_3_ventilation_62_1_2019,60 -attic_ventilation,level_3_ventilation_62_1_2019,110 -audience_seating_ventilation,level_3_ventilation_62_1_2019,83 -baggage_carousel_ventilation,level_3_ventilation_62_1_2019,63 -banking_ventilation,level_3_ventilation_62_1_2019,46 -classroom_lecture_training_ventilation,level_3_ventilation_62_1_2019,18 -computer_room_ventilation,level_3_ventilation_62_1_2019,19 -conference_meeting_multipurpose_ventilation,level_3_ventilation_62_1_2019,37 -confinement_cells_ventilation,level_3_ventilation_62_1_2019,13 -copy_print_ventilation,level_3_ventilation_62_1_2019,64 -corridor_ventilation,level_3_ventilation_62_1_2019,38 -courtroom_ventilation,level_3_ventilation_62_1_2019,84 -datacenterhighite_ventilation,level_3_ventilation_62_1_2019,110 -datacenterlowite_ventilation,level_3_ventilation_62_1_2019,110 -dining_ventilation,level_3_ventilation_62_1_2019,34 -dressing_room_ventilation,level_3_ventilation_62_1_2019,95 -electrical_mechanical_ventilation,level_3_ventilation_62_1_2019,110 -emergency_room_ventilation,level_3_ventilation_62_1_2019,79 -exam_treatment_ventilation,level_3_ventilation_62_1_2019,68 -exercise_area_ventilation,level_3_ventilation_62_1_2019,103 -exhibit_ventilation,level_3_ventilation_62_1_2019,89 -guest_room_ventilation,level_3_ventilation_62_1_2019,41 -imaging_ventilation,level_3_ventilation_62_1_2019,66 -judges_chambers_ventilation,level_3_ventilation_62_1_2019,85 -food_preparation_ventilation,level_3_ventilation_62_1_2019,33 -laboratory_ventilation,level_3_ventilation_62_1_2019,28 -laundry_washing_ventilation,level_3_ventilation_62_1_2019,42 -library_ventilation,level_3_ventilation_62_1_2019,86 -living_quarters_ventilation,level_3_ventilation_62_1_2019,40 -loading_dock_ventilation,level_3_ventilation_62_1_2019,54 -lobby_ventilation,level_3_ventilation_62_1_2019,60 -locker_room_ventilation,level_3_ventilation_62_1_2019,35 -lounge_breakroom_ventilation,level_3_ventilation_62_1_2019,35 -manufacturing_ventilation,level_3_ventilation_62_1_2019,50 -medical_supply_ventilation,level_3_ventilation_62_1_2019,52 -multifamily_ventilation,level_3_ventilation_62_1_2019,41 -nursery_ventilation,level_3_ventilation_62_1_2019,65 -nurses_station_ventilation,level_3_ventilation_62_1_2019,63 -office_ventilation,level_3_ventilation_62_1_2019,62 -office_enclosed_ventilation,level_3_ventilation_62_1_2019,62 -operating_room_ventilation,level_3_ventilation_62_1_2019,81 -patient_room_ventilation,level_3_ventilation_62_1_2019,80 -pharmacy_ventilation,level_3_ventilation_62_1_2019,52 -physical_therapy_ventilation,level_3_ventilation_62_1_2019,70 -playing_area_ventilation,level_3_ventilation_62_1_2019,102 -plenum_ventilation,level_3_ventilation_62_1_2019,110 -post_office_ventilation,level_3_ventilation_62_1_2019,54 -recovery_ventilation,level_3_ventilation_62_1_2019,80 -recreation_common_living_ventilation,level_3_ventilation_62_1_2019,45 -retail_sales_ventilation,level_3_ventilation_62_1_2019,91 -shaft_ventilation,level_3_ventilation_62_1_2019,110 -sleeping_quarters_ventilation,level_3_ventilation_62_1_2019,40 -sports_arena_ventilation,level_3_ventilation_62_1_2019,102 -stairwell_ventilation,level_3_ventilation_62_1_2019,110 -storage_ventilation,level_3_ventilation_62_1_2019,61 -transportation_ventilation,level_3_ventilation_62_1_2019,57 -workshop_ventilation,level_3_ventilation_62_1_2019,50 -worship_ventilation,level_3_ventilation_62_1_2019,90 -correctional_facilities_booking_waiting_ventilation,level_3_ventilation_62_1_2019,12 -correctional_facilities_day_room_ventilation,level_3_ventilation_62_1_2019,14 -correctional_facilities_guard_stations_ventilation,level_3_ventilation_62_1_2019,15 -educational_facilities_art_classroom_ventilation,level_3_ventilation_62_1_2019,16 -educational_facilities_classrooms_ages_5-8_ventilation,level_3_ventilation_62_1_2019,17 -educational_facilities_daycare_through_age_4_ventilation,level_3_ventilation_62_1_2019,21 -educational_facilities_lecture_classroom_ventilation,level_3_ventilation_62_1_2019,22 -educational_facilities_lecture_hall_fixed_seats_ventilation,level_3_ventilation_62_1_2019,23 -educational_facilities_media_center_ventilation,level_3_ventilation_62_1_2019,25 -educational_facilities_multi-use_assembly_ventilation,level_3_ventilation_62_1_2019,26 -educational_facilities_music_theater_dance_ventilation,level_3_ventilation_62_1_2019,27 -educational_facilities_science_laboratories_ventilation,level_3_ventilation_62_1_2019,29 -educational_facilities_wood_metal_shop_ventilation,level_3_ventilation_62_1_2019,30 -food_and_beverage_service_bars_cocktail_lounges_ventilation,level_3_ventilation_62_1_2019,31 -food_and_beverage_service_cafeteria_fast_food_dining_ventilation,level_3_ventilation_62_1_2019,32 -hotels_motels_resorts_dormitories_lobbies_prefunction_ventilation,level_3_ventilation_62_1_2019,44 -miscellaneous_spaces_bank_vaults_safe_deposit_ventilation,level_3_ventilation_62_1_2019,47 -miscellaneous_spaces_computer_not_printing_ventilation,level_3_ventilation_62_1_2019,48 -miscellaneous_spaces_photo_studios_ventilation,level_3_ventilation_62_1_2019,53 -miscellaneous_spaces_warehouses_ventilation,level_3_ventilation_62_1_2019,58 -public_assembly_spaces_lobbies_ventilation,level_3_ventilation_62_1_2019,87 -public_assembly_spaces_museums_childrens_ventilation,level_3_ventilation_62_1_2019,88 -retail_barber_shop_ventilation,level_3_ventilation_62_1_2019,92 -retail_beauty_and_nail_salons_ventilation,level_3_ventilation_62_1_2019,93 -retail_coin-operated_laundries_ventilation,level_3_ventilation_62_1_2019,94 -retail_pet_shops_animal_areas_ventilation,level_3_ventilation_62_1_2019,96 -retail_supermarket_ventilation,level_3_ventilation_62_1_2019,97 -sports_and_entertainment_bowling_alley_seating_ventilation,level_3_ventilation_62_1_2019,98 -sports_and_entertainment_disco_dance_floors_ventilation,level_3_ventilation_62_1_2019,99 -sports_and_entertainment_gambling_casinos_ventilation,level_3_ventilation_62_1_2019,100 -sports_and_entertainment_game_arcades_ventilation,level_3_ventilation_62_1_2019,101 -sports_and_entertainment_health_club_weight_rooms_ventilation,level_3_ventilation_62_1_2019,104 -sports_and_entertainment_spectator_areas_ventilation,level_3_ventilation_62_1_2019,105 -sports_and_entertainment_stages_studios_ventilation,level_3_ventilation_62_1_2019,106 -sports_and_entertainment_swimming_pool_deck_ventilation,level_3_ventilation_62_1_2019,107 -airport_concourse_ventilation,level_3_ventilation_62_1_2016,50 -atrium_ventilation,level_3_ventilation_62_1_2016,47 -attic_ventilation,level_3_ventilation_62_1_2016,79 -audience_seating_ventilation,level_3_ventilation_62_1_2016,52 -baggage_carousel_ventilation,level_3_ventilation_62_1_2016,50 -banking_ventilation,level_3_ventilation_62_1_2016,35 -classroom_lecture_training_ventilation,level_3_ventilation_62_1_2016,8 -computer_room_ventilation,level_3_ventilation_62_1_2016,15 -conference_meeting_multipurpose_ventilation,level_3_ventilation_62_1_2016,25 -confinement_cells_ventilation,level_3_ventilation_62_1_2016,1 -copy_print_ventilation,level_3_ventilation_62_1_2016,51 -corridor_ventilation,level_3_ventilation_62_1_2016,26 -courtroom_ventilation,level_3_ventilation_62_1_2016,54 -datacenterhighite_ventilation,level_3_ventilation_62_1_2016,79 -datacenterlowite_ventilation,level_3_ventilation_62_1_2016,79 -dining_ventilation,level_3_ventilation_62_1_2016,19 -dressing_room_ventilation,level_3_ventilation_62_1_2016,63 -electrical_mechanical_ventilation,level_3_ventilation_62_1_2016,79 -exercise_area_ventilation,level_3_ventilation_62_1_2016,73 -exhibit_ventilation,level_3_ventilation_62_1_2016,59 -guest_room_ventilation,level_3_ventilation_62_1_2016,28 -judges_chambers_ventilation,level_3_ventilation_62_1_2016,55 -food_preparation_ventilation,level_3_ventilation_62_1_2016,22 -laboratory_ventilation,level_3_ventilation_62_1_2016,12 -laundry_washing_ventilation,level_3_ventilation_62_1_2016,30 -library_ventilation,level_3_ventilation_62_1_2016,56 -living_quarters_ventilation,level_3_ventilation_62_1_2016,29 -loading_dock_ventilation,level_3_ventilation_62_1_2016,41 -lobby_ventilation,level_3_ventilation_62_1_2016,47 -locker_room_ventilation,level_3_ventilation_62_1_2016,23 -lounge_breakroom_ventilation,level_3_ventilation_62_1_2016,23 -medical_supply_ventilation,level_3_ventilation_62_1_2016,39 -multifamily_ventilation,level_3_ventilation_62_1_2016,28 -nurses_station_ventilation,level_3_ventilation_62_1_2016,50 -office_ventilation,level_3_ventilation_62_1_2016,49 -office_enclosed_ventilation,level_3_ventilation_62_1_2016,49 -pharmacy_ventilation,level_3_ventilation_62_1_2016,39 -playing_area_ventilation,level_3_ventilation_62_1_2016,69 -plenum_ventilation,level_3_ventilation_62_1_2016,79 -post_office_ventilation,level_3_ventilation_62_1_2016,41 -recreation_common_living_ventilation,level_3_ventilation_62_1_2016,33 -retail_sales_ventilation,level_3_ventilation_62_1_2016,62 -shaft_ventilation,level_3_ventilation_62_1_2016,79 -sleeping_quarters_ventilation,level_3_ventilation_62_1_2016,29 -sports_arena_ventilation,level_3_ventilation_62_1_2016,69 -stairwell_ventilation,level_3_ventilation_62_1_2016,79 -storage_ventilation,level_3_ventilation_62_1_2016,48 -transportation_ventilation,level_3_ventilation_62_1_2016,44 -worship_ventilation,level_3_ventilation_62_1_2016,53 -correctional_facilities_booking_waiting_ventilation,level_3_ventilation_62_1_2016,4 -correctional_facilities_day_room_ventilation,level_3_ventilation_62_1_2016,2 -correctional_facilities_guard_stations_ventilation,level_3_ventilation_62_1_2016,3 -educational_facilities_art_classroom_ventilation,level_3_ventilation_62_1_2016,11 -educational_facilities_classrooms_ages_5-8_ventilation,level_3_ventilation_62_1_2016,7 -educational_facilities_daycare_through_age_4_ventilation,level_3_ventilation_62_1_2016,5 -educational_facilities_lecture_classroom_ventilation,level_3_ventilation_62_1_2016,9 -educational_facilities_lecture_hall_fixed_seats_ventilation,level_3_ventilation_62_1_2016,10 -educational_facilities_media_center_ventilation,level_3_ventilation_62_1_2016,16 -educational_facilities_multi-use_assembly_ventilation,level_3_ventilation_62_1_2016,18 -educational_facilities_music_theater_dance_ventilation,level_3_ventilation_62_1_2016,17 -educational_facilities_science_laboratories_ventilation,level_3_ventilation_62_1_2016,13 -educational_facilities_wood_metal_shop_ventilation,level_3_ventilation_62_1_2016,14 -food_and_beverage_service_bars_cocktail_lounges_ventilation,level_3_ventilation_62_1_2016,21 -food_and_beverage_service_cafeteria_fast_food_dining_ventilation,level_3_ventilation_62_1_2016,20 -hotels_motels_resorts_dormitories_lobbies_prefunction_ventilation,level_3_ventilation_62_1_2016,32 -miscellaneous_spaces_bank_vaults_safe_deposit_ventilation,level_3_ventilation_62_1_2016,34 -miscellaneous_spaces_computer_not_printing_ventilation,level_3_ventilation_62_1_2016,36 -miscellaneous_spaces_photo_studios_ventilation,level_3_ventilation_62_1_2016,40 -miscellaneous_spaces_warehouses_ventilation,level_3_ventilation_62_1_2016,45 -public_assembly_spaces_lobbies_ventilation,level_3_ventilation_62_1_2016,57 -public_assembly_spaces_museums_childrens_ventilation,level_3_ventilation_62_1_2016,58 -retail_barber_shop_ventilation,level_3_ventilation_62_1_2016,64 -retail_beauty_and_nail_salons_ventilation,level_3_ventilation_62_1_2016,65 -retail_coin-operated_laundries_ventilation,level_3_ventilation_62_1_2016,68 -retail_pet_shops_animal_areas_ventilation,level_3_ventilation_62_1_2016,66 -retail_supermarket_ventilation,level_3_ventilation_62_1_2016,67 -sports_and_entertainment_bowling_alley_seating_ventilation,level_3_ventilation_62_1_2016,75 -sports_and_entertainment_disco_dance_floors_ventilation,level_3_ventilation_62_1_2016,72 -sports_and_entertainment_gambling_casinos_ventilation,level_3_ventilation_62_1_2016,76 -sports_and_entertainment_game_arcades_ventilation,level_3_ventilation_62_1_2016,77 -sports_and_entertainment_health_club_weight_rooms_ventilation,level_3_ventilation_62_1_2016,74 -sports_and_entertainment_spectator_areas_ventilation,level_3_ventilation_62_1_2016,70 -sports_and_entertainment_stages_studios_ventilation,level_3_ventilation_62_1_2016,78 -sports_and_entertainment_swimming_pool_deck_ventilation,level_3_ventilation_62_1_2016,71 -airport_concourse_ventilation,level_3_ventilation_62_1_2013,50 -atrium_ventilation,level_3_ventilation_62_1_2013,47 -attic_ventilation,level_3_ventilation_62_1_2013,79 -audience_seating_ventilation,level_3_ventilation_62_1_2013,52 -baggage_carousel_ventilation,level_3_ventilation_62_1_2013,50 -banking_ventilation,level_3_ventilation_62_1_2013,35 -classroom_lecture_training_ventilation,level_3_ventilation_62_1_2013,8 -computer_room_ventilation,level_3_ventilation_62_1_2013,15 -conference_meeting_multipurpose_ventilation,level_3_ventilation_62_1_2013,25 -confinement_cells_ventilation,level_3_ventilation_62_1_2013,1 -copy_print_ventilation,level_3_ventilation_62_1_2013,51 -corridor_ventilation,level_3_ventilation_62_1_2013,26 -courtroom_ventilation,level_3_ventilation_62_1_2013,54 -datacenterhighite_ventilation,level_3_ventilation_62_1_2013,79 -datacenterlowite_ventilation,level_3_ventilation_62_1_2013,79 -dining_ventilation,level_3_ventilation_62_1_2013,19 -dressing_room_ventilation,level_3_ventilation_62_1_2013,63 -electrical_mechanical_ventilation,level_3_ventilation_62_1_2013,79 -exercise_area_ventilation,level_3_ventilation_62_1_2013,73 -exhibit_ventilation,level_3_ventilation_62_1_2013,59 -guest_room_ventilation,level_3_ventilation_62_1_2013,28 -judges_chambers_ventilation,level_3_ventilation_62_1_2013,55 -food_preparation_ventilation,level_3_ventilation_62_1_2013,22 -laboratory_ventilation,level_3_ventilation_62_1_2013,12 -laundry_washing_ventilation,level_3_ventilation_62_1_2013,30 -library_ventilation,level_3_ventilation_62_1_2013,56 -living_quarters_ventilation,level_3_ventilation_62_1_2013,29 -loading_dock_ventilation,level_3_ventilation_62_1_2013,41 -lobby_ventilation,level_3_ventilation_62_1_2013,47 -locker_room_ventilation,level_3_ventilation_62_1_2013,23 -lounge_breakroom_ventilation,level_3_ventilation_62_1_2013,23 -medical_supply_ventilation,level_3_ventilation_62_1_2013,39 -multifamily_ventilation,level_3_ventilation_62_1_2013,28 -nurses_station_ventilation,level_3_ventilation_62_1_2013,50 -office_ventilation,level_3_ventilation_62_1_2013,49 -office_enclosed_ventilation,level_3_ventilation_62_1_2013,49 -pharmacy_ventilation,level_3_ventilation_62_1_2013,39 -playing_area_ventilation,level_3_ventilation_62_1_2013,69 -plenum_ventilation,level_3_ventilation_62_1_2013,79 -post_office_ventilation,level_3_ventilation_62_1_2013,41 -recreation_common_living_ventilation,level_3_ventilation_62_1_2013,33 -retail_sales_ventilation,level_3_ventilation_62_1_2013,62 -shaft_ventilation,level_3_ventilation_62_1_2013,79 -sleeping_quarters_ventilation,level_3_ventilation_62_1_2013,29 -sports_arena_ventilation,level_3_ventilation_62_1_2013,69 -stairwell_ventilation,level_3_ventilation_62_1_2013,79 -storage_ventilation,level_3_ventilation_62_1_2013,48 -transportation_ventilation,level_3_ventilation_62_1_2013,44 -worship_ventilation,level_3_ventilation_62_1_2013,53 -correctional_facilities_booking_waiting_ventilation,level_3_ventilation_62_1_2013,4 -correctional_facilities_day_room_ventilation,level_3_ventilation_62_1_2013,2 -correctional_facilities_guard_stations_ventilation,level_3_ventilation_62_1_2013,3 -educational_facilities_art_classroom_ventilation,level_3_ventilation_62_1_2013,11 -educational_facilities_classrooms_ages_5-8_ventilation,level_3_ventilation_62_1_2013,7 -educational_facilities_daycare_through_age_4_ventilation,level_3_ventilation_62_1_2013,5 -educational_facilities_lecture_classroom_ventilation,level_3_ventilation_62_1_2013,9 -educational_facilities_lecture_hall_fixed_seats_ventilation,level_3_ventilation_62_1_2013,10 -educational_facilities_media_center_ventilation,level_3_ventilation_62_1_2013,16 -educational_facilities_multi-use_assembly_ventilation,level_3_ventilation_62_1_2013,18 -educational_facilities_music_theater_dance_ventilation,level_3_ventilation_62_1_2013,17 -educational_facilities_science_laboratories_ventilation,level_3_ventilation_62_1_2013,12 -educational_facilities_wood_metal_shop_ventilation,level_3_ventilation_62_1_2013,14 -food_and_beverage_service_bars_cocktail_lounges_ventilation,level_3_ventilation_62_1_2013,21 -food_and_beverage_service_cafeteria_fast_food_dining_ventilation,level_3_ventilation_62_1_2013,20 -hotels_motels_resorts_dormitories_lobbies_prefunction_ventilation,level_3_ventilation_62_1_2013,32 -miscellaneous_spaces_bank_vaults_safe_deposit_ventilation,level_3_ventilation_62_1_2013,34 -miscellaneous_spaces_computer_not_printing_ventilation,level_3_ventilation_62_1_2013,36 -miscellaneous_spaces_photo_studios_ventilation,level_3_ventilation_62_1_2013,40 -miscellaneous_spaces_warehouses_ventilation,level_3_ventilation_62_1_2013,45 -public_assembly_spaces_lobbies_ventilation,level_3_ventilation_62_1_2013,57 -public_assembly_spaces_museums_childrens_ventilation,level_3_ventilation_62_1_2013,58 -retail_barber_shop_ventilation,level_3_ventilation_62_1_2013,64 -retail_beauty_and_nail_salons_ventilation,level_3_ventilation_62_1_2013,65 -retail_coin-operated_laundries_ventilation,level_3_ventilation_62_1_2013,68 -retail_pet_shops_animal_areas_ventilation,level_3_ventilation_62_1_2013,66 -retail_supermarket_ventilation,level_3_ventilation_62_1_2013,67 -sports_and_entertainment_bowling_alley_seating_ventilation,level_3_ventilation_62_1_2013,75 -sports_and_entertainment_disco_dance_floors_ventilation,level_3_ventilation_62_1_2013,72 -sports_and_entertainment_gambling_casinos_ventilation,level_3_ventilation_62_1_2013,76 -sports_and_entertainment_game_arcades_ventilation,level_3_ventilation_62_1_2013,77 -sports_and_entertainment_health_club_weight_rooms_ventilation,level_3_ventilation_62_1_2013,74 -sports_and_entertainment_spectator_areas_ventilation,level_3_ventilation_62_1_2013,70 -sports_and_entertainment_stages_studios_ventilation,level_3_ventilation_62_1_2013,78 -sports_and_entertainment_swimming_pool_deck_ventilation,level_3_ventilation_62_1_2013,71 -airport_concourse_ventilation,level_3_ventilation_62_1_2010,38 -atrium_ventilation,level_3_ventilation_62_1_2010,35 -attic_ventilation,level_3_ventilation_62_1_2010,79 -audience_seating_ventilation,level_3_ventilation_62_1_2010,51 -baggage_carousel_ventilation,level_3_ventilation_62_1_2010,38 -banking_ventilation,level_3_ventilation_62_1_2010,41 -classroom_lecture_training_ventilation,level_3_ventilation_62_1_2010,8 -computer_room_ventilation,level_3_ventilation_62_1_2010,15 -conference_meeting_multipurpose_ventilation,level_3_ventilation_62_1_2010,25 -confinement_cells_ventilation,level_3_ventilation_62_1_2010,1 -copy_print_ventilation,level_3_ventilation_62_1_2010,39 -corridor_ventilation,level_3_ventilation_62_1_2010,26 -courtroom_ventilation,level_3_ventilation_62_1_2010,53 -datacenterhighite_ventilation,level_3_ventilation_62_1_2010,79 -datacenterlowite_ventilation,level_3_ventilation_62_1_2010,79 -dining_ventilation,level_3_ventilation_62_1_2010,19 -dressing_room_ventilation,level_3_ventilation_62_1_2010,62 -electrical_mechanical_ventilation,level_3_ventilation_62_1_2010,79 -exercise_area_ventilation,level_3_ventilation_62_1_2010,73 -exhibit_ventilation,level_3_ventilation_62_1_2010,58 -guest_room_ventilation,level_3_ventilation_62_1_2010,28 -judges_chambers_ventilation,level_3_ventilation_62_1_2010,54 -food_preparation_ventilation,level_3_ventilation_62_1_2010,22 -laboratory_ventilation,level_3_ventilation_62_1_2010,12 -laundry_washing_ventilation,level_3_ventilation_62_1_2010,30 -library_ventilation,level_3_ventilation_62_1_2010,55 -living_quarters_ventilation,level_3_ventilation_62_1_2010,29 -loading_dock_ventilation,level_3_ventilation_62_1_2010,46 -lobby_ventilation,level_3_ventilation_62_1_2010,35 -locker_room_ventilation,level_3_ventilation_62_1_2010,23 -lounge_breakroom_ventilation,level_3_ventilation_62_1_2010,23 -medical_supply_ventilation,level_3_ventilation_62_1_2010,44 -multifamily_ventilation,level_3_ventilation_62_1_2010,28 -nurses_station_ventilation,level_3_ventilation_62_1_2010,38 -office_ventilation,level_3_ventilation_62_1_2010,37 -office_enclosed_ventilation,level_3_ventilation_62_1_2010,37 -pharmacy_ventilation,level_3_ventilation_62_1_2010,44 -playing_area_ventilation,level_3_ventilation_62_1_2010,69 -plenum_ventilation,level_3_ventilation_62_1_2010,79 -post_office_ventilation,level_3_ventilation_62_1_2010,46 -recreation_common_living_ventilation,level_3_ventilation_62_1_2010,33 -retail_sales_ventilation,level_3_ventilation_62_1_2010,61 -shaft_ventilation,level_3_ventilation_62_1_2010,79 -sleeping_quarters_ventilation,level_3_ventilation_62_1_2010,29 -sports_arena_ventilation,level_3_ventilation_62_1_2010,68 -stairwell_ventilation,level_3_ventilation_62_1_2010,79 -storage_ventilation,level_3_ventilation_62_1_2010,36 -transportation_ventilation,level_3_ventilation_62_1_2010,49 -worship_ventilation,level_3_ventilation_62_1_2010,52 -correctional_facilities_booking_waiting_ventilation,level_3_ventilation_62_1_2010,4 -correctional_facilities_day_room_ventilation,level_3_ventilation_62_1_2010,2 -correctional_facilities_guard_stations_ventilation,level_3_ventilation_62_1_2010,3 -educational_facilities_art_classroom_ventilation,level_3_ventilation_62_1_2010,11 -educational_facilities_classrooms_ages_5-8_ventilation,level_3_ventilation_62_1_2010,7 -educational_facilities_daycare_through_age_4_ventilation,level_3_ventilation_62_1_2010,5 -educational_facilities_lecture_classroom_ventilation,level_3_ventilation_62_1_2010,9 -educational_facilities_lecture_hall_fixed_seats_ventilation,level_3_ventilation_62_1_2010,10 -educational_facilities_media_center_ventilation,level_3_ventilation_62_1_2010,16 -educational_facilities_multi-use_assembly_ventilation,level_3_ventilation_62_1_2010,18 -educational_facilities_music_theater_dance_ventilation,level_3_ventilation_62_1_2010,17 -educational_facilities_science_laboratories_ventilation,level_3_ventilation_62_1_2010,12 -educational_facilities_wood_metal_shop_ventilation,level_3_ventilation_62_1_2010,14 -food_and_beverage_service_bars_cocktail_lounges_ventilation,level_3_ventilation_62_1_2010,21 -food_and_beverage_service_cafeteria_fast_food_dining_ventilation,level_3_ventilation_62_1_2010,20 -hotels_motels_resorts_dormitories_lobbies_prefunction_ventilation,level_3_ventilation_62_1_2010,32 -miscellaneous_spaces_bank_vaults_safe_deposit_ventilation,level_3_ventilation_62_1_2010,40 -miscellaneous_spaces_computer_not_printing_ventilation,level_3_ventilation_62_1_2010,42 -miscellaneous_spaces_photo_studios_ventilation,level_3_ventilation_62_1_2010,45 -miscellaneous_spaces_warehouses_ventilation,level_3_ventilation_62_1_2010,50 -public_assembly_spaces_lobbies_ventilation,level_3_ventilation_62_1_2010,56 -public_assembly_spaces_museums_childrens_ventilation,level_3_ventilation_62_1_2010,57 -retail_barber_shop_ventilation,level_3_ventilation_62_1_2010,63 -retail_beauty_and_nail_salons_ventilation,level_3_ventilation_62_1_2010,64 -retail_coin-operated_laundries_ventilation,level_3_ventilation_62_1_2010,67 -retail_pet_shops_animal_areas_ventilation,level_3_ventilation_62_1_2010,65 -retail_supermarket_ventilation,level_3_ventilation_62_1_2010,66 -sports_and_entertainment_bowling_alley_seating_ventilation,level_3_ventilation_62_1_2010,75 -sports_and_entertainment_disco_dance_floors_ventilation,level_3_ventilation_62_1_2010,72 -sports_and_entertainment_gambling_casinos_ventilation,level_3_ventilation_62_1_2010,76 -sports_and_entertainment_game_arcades_ventilation,level_3_ventilation_62_1_2010,77 -sports_and_entertainment_health_club_weight_rooms_ventilation,level_3_ventilation_62_1_2010,74 -sports_and_entertainment_spectator_areas_ventilation,level_3_ventilation_62_1_2010,70 -sports_and_entertainment_stages_studios_ventilation,level_3_ventilation_62_1_2010,78 -sports_and_entertainment_swimming_pool_deck_ventilation,level_3_ventilation_62_1_2010,71 -airport_concourse_ventilation,level_3_ventilation_62_1_2007,34 -atrium_ventilation,level_3_ventilation_62_1_2007,36 -attic_ventilation,level_3_ventilation_62_1_2007,75 -audience_seating_ventilation,level_3_ventilation_62_1_2007,47 -baggage_carousel_ventilation,level_3_ventilation_62_1_2007,34 -banking_ventilation,level_3_ventilation_62_1_2007,34 -classroom_lecture_training_ventilation,level_3_ventilation_62_1_2007,8 -computer_room_ventilation,level_3_ventilation_62_1_2007,15 -conference_meeting_multipurpose_ventilation,level_3_ventilation_62_1_2007,24 -confinement_cells_ventilation,level_3_ventilation_62_1_2007,1 -copy_print_ventilation,level_3_ventilation_62_1_2007,35 -corridor_ventilation,level_3_ventilation_62_1_2007,25 -courtroom_ventilation,level_3_ventilation_62_1_2007,49 -datacenterhighite_ventilation,level_3_ventilation_62_1_2007,75 -datacenterlowite_ventilation,level_3_ventilation_62_1_2007,75 -dining_ventilation,level_3_ventilation_62_1_2007,19 -dressing_room_ventilation,level_3_ventilation_62_1_2007,58 -electrical_mechanical_ventilation,level_3_ventilation_62_1_2007,75 -exercise_area_ventilation,level_3_ventilation_62_1_2007,69 -exhibit_ventilation,level_3_ventilation_62_1_2007,54 -guest_room_ventilation,level_3_ventilation_62_1_2007,27 -judges_chambers_ventilation,level_3_ventilation_62_1_2007,50 -laboratory_ventilation,level_3_ventilation_62_1_2007,12 -laundry_washing_ventilation,level_3_ventilation_62_1_2007,29 -library_ventilation,level_3_ventilation_62_1_2007,51 -living_quarters_ventilation,level_3_ventilation_62_1_2007,28 -loading_dock_ventilation,level_3_ventilation_62_1_2007,43 -lobby_ventilation,level_3_ventilation_62_1_2007,36 -locker_room_ventilation,level_3_ventilation_62_1_2007,22 -lounge_breakroom_ventilation,level_3_ventilation_62_1_2007,22 -medical_supply_ventilation,level_3_ventilation_62_1_2007,41 -multifamily_ventilation,level_3_ventilation_62_1_2007,27 -nurses_station_ventilation,level_3_ventilation_62_1_2007,34 -office_ventilation,level_3_ventilation_62_1_2007,33 -office_enclosed_ventilation,level_3_ventilation_62_1_2007,33 -pharmacy_ventilation,level_3_ventilation_62_1_2007,41 -playing_area_ventilation,level_3_ventilation_62_1_2007,65 -plenum_ventilation,level_3_ventilation_62_1_2007,75 -post_office_ventilation,level_3_ventilation_62_1_2007,43 -recreation_common_living_ventilation,level_3_ventilation_62_1_2007,32 -retail_sales_ventilation,level_3_ventilation_62_1_2007,57 -shaft_ventilation,level_3_ventilation_62_1_2007,75 -sleeping_quarters_ventilation,level_3_ventilation_62_1_2007,28 -sports_arena_ventilation,level_3_ventilation_62_1_2007,64 -stairwell_ventilation,level_3_ventilation_62_1_2007,75 -storage_ventilation,level_3_ventilation_62_1_2007,26 -transportation_ventilation,level_3_ventilation_62_1_2007,45 -worship_ventilation,level_3_ventilation_62_1_2007,48 -correctional_facilities_booking_waiting_ventilation,level_3_ventilation_62_1_2007,4 -correctional_facilities_day_room_ventilation,level_3_ventilation_62_1_2007,2 -correctional_facilities_guard_stations_ventilation,level_3_ventilation_62_1_2007,3 -educational_facilities_art_classroom_ventilation,level_3_ventilation_62_1_2007,11 -educational_facilities_classrooms_ages_5-8_ventilation,level_3_ventilation_62_1_2007,7 -educational_facilities_daycare_through_age_4_ventilation,level_3_ventilation_62_1_2007,5 -educational_facilities_lecture_classroom_ventilation,level_3_ventilation_62_1_2007,9 -educational_facilities_lecture_hall_fixed_seats_ventilation,level_3_ventilation_62_1_2007,10 -educational_facilities_media_center_ventilation,level_3_ventilation_62_1_2007,16 -educational_facilities_multi-use_assembly_ventilation,level_3_ventilation_62_1_2007,18 -educational_facilities_music_theater_dance_ventilation,level_3_ventilation_62_1_2007,17 -educational_facilities_science_laboratories_ventilation,level_3_ventilation_62_1_2007,12 -educational_facilities_wood_metal_shop_ventilation,level_3_ventilation_62_1_2007,14 -food_and_beverage_service_bars_cocktail_lounges_ventilation,level_3_ventilation_62_1_2007,21 -food_and_beverage_service_cafeteria_fast_food_dining_ventilation,level_3_ventilation_62_1_2007,20 -hotels_motels_resorts_dormitories_lobbies_prefunction_ventilation,level_3_ventilation_62_1_2007,31 -miscellaneous_spaces_bank_vaults_safe_deposit_ventilation,level_3_ventilation_62_1_2007,37 -miscellaneous_spaces_computer_not_printing_ventilation,level_3_ventilation_62_1_2007,38 -miscellaneous_spaces_photo_studios_ventilation,level_3_ventilation_62_1_2007,42 -miscellaneous_spaces_warehouses_ventilation,level_3_ventilation_62_1_2007,46 -public_assembly_spaces_lobbies_ventilation,level_3_ventilation_62_1_2007,52 -public_assembly_spaces_museums_childrens_ventilation,level_3_ventilation_62_1_2007,53 -retail_barber_shop_ventilation,level_3_ventilation_62_1_2007,59 -retail_beauty_and_nail_salons_ventilation,level_3_ventilation_62_1_2007,60 -retail_coin-operated_laundries_ventilation,level_3_ventilation_62_1_2007,63 -retail_pet_shops_animal_areas_ventilation,level_3_ventilation_62_1_2007,61 -retail_supermarket_ventilation,level_3_ventilation_62_1_2007,62 -sports_and_entertainment_bowling_alley_seating_ventilation,level_3_ventilation_62_1_2007,71 -sports_and_entertainment_disco_dance_floors_ventilation,level_3_ventilation_62_1_2007,68 -sports_and_entertainment_gambling_casinos_ventilation,level_3_ventilation_62_1_2007,72 -sports_and_entertainment_game_arcades_ventilation,level_3_ventilation_62_1_2007,73 -sports_and_entertainment_health_club_weight_rooms_ventilation,level_3_ventilation_62_1_2007,70 -sports_and_entertainment_spectator_areas_ventilation,level_3_ventilation_62_1_2007,66 -sports_and_entertainment_stages_studios_ventilation,level_3_ventilation_62_1_2007,74 -sports_and_entertainment_swimming_pool_deck_ventilation,level_3_ventilation_62_1_2007,67 -airport_concourse_ventilation,level_3_ventilation_62_1_2004,28 -atrium_ventilation,level_3_ventilation_62_1_2004,30 -attic_ventilation,level_3_ventilation_62_1_2004,64 -audience_seating_ventilation,level_3_ventilation_62_1_2004,38 -baggage_carousel_ventilation,level_3_ventilation_62_1_2004,28 -banking_ventilation,level_3_ventilation_62_1_2004,28 -classroom_lecture_training_ventilation,level_3_ventilation_62_1_2004,7 -computer_room_ventilation,level_3_ventilation_62_1_2004,13 -conference_meeting_multipurpose_ventilation,level_3_ventilation_62_1_2004,20 -confinement_cells_ventilation,level_3_ventilation_62_1_2004,1 -copy_print_ventilation,level_3_ventilation_62_1_2004,29 -corridor_ventilation,level_3_ventilation_62_1_2004,21 -courtroom_ventilation,level_3_ventilation_62_1_2004,40 -datacenterhighite_ventilation,level_3_ventilation_62_1_2004,64 -datacenterlowite_ventilation,level_3_ventilation_62_1_2004,64 -dining_ventilation,level_3_ventilation_62_1_2004,17 -dressing_room_ventilation,level_3_ventilation_62_1_2004,47 -electrical_mechanical_ventilation,level_3_ventilation_62_1_2004,64 -exercise_area_ventilation,level_3_ventilation_62_1_2004,58 -exhibit_ventilation,level_3_ventilation_62_1_2004,45 -guest_room_ventilation,level_3_ventilation_62_1_2004,23 -judges_chambers_ventilation,level_3_ventilation_62_1_2004,41 -laboratory_ventilation,level_3_ventilation_62_1_2004,11 -library_ventilation,level_3_ventilation_62_1_2004,42 -living_quarters_ventilation,level_3_ventilation_62_1_2004,24 -loading_dock_ventilation,level_3_ventilation_62_1_2004,35 -lobby_ventilation,level_3_ventilation_62_1_2004,30 -medical_supply_ventilation,level_3_ventilation_62_1_2004,33 -multifamily_ventilation,level_3_ventilation_62_1_2004,23 -nurses_station_ventilation,level_3_ventilation_62_1_2004,28 -office_ventilation,level_3_ventilation_62_1_2004,27 -office_enclosed_ventilation,level_3_ventilation_62_1_2004,27 -pharmacy_ventilation,level_3_ventilation_62_1_2004,33 -playing_area_ventilation,level_3_ventilation_62_1_2004,53 -plenum_ventilation,level_3_ventilation_62_1_2004,64 -post_office_ventilation,level_3_ventilation_62_1_2004,35 -recreation_common_living_ventilation,level_3_ventilation_62_1_2004,26 -retail_sales_ventilation,level_3_ventilation_62_1_2004,46 -shaft_ventilation,level_3_ventilation_62_1_2004,64 -sleeping_quarters_ventilation,level_3_ventilation_62_1_2004,24 -sports_arena_ventilation,level_3_ventilation_62_1_2004,53 -stairwell_ventilation,level_3_ventilation_62_1_2004,64 -storage_ventilation,level_3_ventilation_62_1_2004,22 -transportation_ventilation,level_3_ventilation_62_1_2004,36 -worship_ventilation,level_3_ventilation_62_1_2004,39 -correctional_facilities_booking_waiting_ventilation,level_3_ventilation_62_1_2004,4 -correctional_facilities_day_room_ventilation,level_3_ventilation_62_1_2004,2 -correctional_facilities_guard_stations_ventilation,level_3_ventilation_62_1_2004,3 -educational_facilities_art_classroom_ventilation,level_3_ventilation_62_1_2004,10 -educational_facilities_classrooms_ages_5-8_ventilation,level_3_ventilation_62_1_2004,6 -educational_facilities_daycare_through_age_4_ventilation,level_3_ventilation_62_1_2004,5 -educational_facilities_lecture_classroom_ventilation,level_3_ventilation_62_1_2004,8 -educational_facilities_lecture_hall_fixed_seats_ventilation,level_3_ventilation_62_1_2004,9 -educational_facilities_media_center_ventilation,level_3_ventilation_62_1_2004,14 -educational_facilities_multi-use_assembly_ventilation,level_3_ventilation_62_1_2004,16 -educational_facilities_music_theater_dance_ventilation,level_3_ventilation_62_1_2004,15 -educational_facilities_science_laboratories_ventilation,level_3_ventilation_62_1_2004,11 -educational_facilities_wood_metal_shop_ventilation,level_3_ventilation_62_1_2004,12 -food_and_beverage_service_bars_cocktail_lounges_ventilation,level_3_ventilation_62_1_2004,19 -food_and_beverage_service_cafeteria_fast_food_dining_ventilation,level_3_ventilation_62_1_2004,18 -hotels_motels_resorts_dormitories_lobbies_prefunction_ventilation,level_3_ventilation_62_1_2004,25 -miscellaneous_spaces_bank_vaults_safe_deposit_ventilation,level_3_ventilation_62_1_2004,31 -miscellaneous_spaces_computer_not_printing_ventilation,level_3_ventilation_62_1_2004,32 -miscellaneous_spaces_photo_studios_ventilation,level_3_ventilation_62_1_2004,34 -miscellaneous_spaces_warehouses_ventilation,level_3_ventilation_62_1_2004,37 -public_assembly_spaces_lobbies_ventilation,level_3_ventilation_62_1_2004,43 -public_assembly_spaces_museums_childrens_ventilation,level_3_ventilation_62_1_2004,44 -retail_barber_shop_ventilation,level_3_ventilation_62_1_2004,48 -retail_beauty_and_nail_salons_ventilation,level_3_ventilation_62_1_2004,49 -retail_coin-operated_laundries_ventilation,level_3_ventilation_62_1_2004,52 -retail_pet_shops_animal_areas_ventilation,level_3_ventilation_62_1_2004,50 -retail_supermarket_ventilation,level_3_ventilation_62_1_2004,51 -sports_and_entertainment_bowling_alley_seating_ventilation,level_3_ventilation_62_1_2004,60 -sports_and_entertainment_disco_dance_floors_ventilation,level_3_ventilation_62_1_2004,57 -sports_and_entertainment_gambling_casinos_ventilation,level_3_ventilation_62_1_2004,61 -sports_and_entertainment_game_arcades_ventilation,level_3_ventilation_62_1_2004,62 -sports_and_entertainment_health_club_weight_rooms_ventilation,level_3_ventilation_62_1_2004,59 -sports_and_entertainment_spectator_areas_ventilation,level_3_ventilation_62_1_2004,55 -sports_and_entertainment_stages_studios_ventilation,level_3_ventilation_62_1_2004,63 -sports_and_entertainment_swimming_pool_deck_ventilation,level_3_ventilation_62_1_2004,56 -emergency_room_ventilation,level_3_ventilation_62_1_1999,75 -emergency_vehicle_garage_ventilation,level_3_ventilation_62_1_1999,58 -exam_treatment_ventilation,level_3_ventilation_62_1_1999,75 -imaging_ventilation,level_3_ventilation_62_1_1999,75 -interior_parking_ventilation,level_3_ventilation_62_1_1999,58 -food_preparation_ventilation,level_3_ventilation_62_1_1999,9 -laundry_washing_ventilation,level_3_ventilation_62_1_1999,4 -locker_room_ventilation,level_3_ventilation_62_1_1999,26 -lounge_breakroom_ventilation,level_3_ventilation_62_1_1999,26 -nursery_ventilation,level_3_ventilation_62_1_1999,77 -operating_room_ventilation,level_3_ventilation_62_1_1999,76 -patient_room_ventilation,level_3_ventilation_62_1_1999,77 -physical_therapy_ventilation,level_3_ventilation_62_1_1999,79 -recovery_ventilation,level_3_ventilation_62_1_1999,77 -restroom_ventilation,level_3_ventilation_62_1_1999,25 -vehicular_maintenance_ventilation,level_3_ventilation_62_1_1999,10 diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2004.csv b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2004.csv deleted file mode 100644 index 4e770b2f3a..0000000000 --- a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2004.csv +++ /dev/null @@ -1,127 +0,0 @@ -method,lighting_primary_space_type,lighting_secondary_space_type,lighting_power_density,unit,rcr_threshold,automatic_daylight_responsive_controls_for_sidelighting,automatic_daylight_responsive_controls_for_toplighting,automatic_partial_off,automatic_full_off,scheduled_shutoff,annotation -BA,Automotive Facility,General,0.9,W/ft2,,,,,,, -BA,Convention Center,General,1.2,W/ft2,,,,,,, -BA,Court House,General,1.2,W/ft2,,,,,,, -BA,Dining: Bar Lounge/Leisure,General,1.3,W/ft2,,,,,,, -BA,Dining: Cafeteria/Fast Food,General,1.4,W/ft2,,,,,,, -BA,Dining: Family,General,1.6,W/ft2,,,,,,, -BA,Dormitory,General,1,W/ft2,,,,,,, -BA,Exercise Center,General,1,W/ft2,,,,,,, -BA,Gymnasium,General,1.1,W/ft2,,,,,,, -BA,Health Care-Clinic,General,1,W/ft2,,,,,,, -BA,Hospital,General,1.2,W/ft2,,,,,,, -BA,Hotel,General,1,W/ft2,,,,,,, -BA,Library,General,1.3,W/ft2,,,,,,, -BA,Manufacturing Facility,General,1.3,W/ft2,,,,,,, -BA,Motel,General,1,W/ft2,,,,,,, -BA,Motion Picture Theater,General,1.2,W/ft2,,,,,,, -BA,Multi-Family,General,0.7,W/ft2,,,,,,, -BA,Museum,General,1.1,W/ft2,,,,,,, -BA,Office,General,1,W/ft2,,,,,,, -BA,Parking Garage,General,0.3,W/ft2,,,,,,, -BA,Penitentiary,General,1,W/ft2,,,,,,, -BA,Performing Arts Theater,General,1.6,W/ft2,,,,,,, -BA,Police/Fire Station,General,1,W/ft2,,,,,,, -BA,Post Office,General,1.1,W/ft2,,,,,,, -BA,Religious Building,General,1.3,W/ft2,,,,,,, -BA,Retail,General,1.5,W/ft2,,,,,,, -BA,School/University,General,1.2,W/ft2,,,,,,, -BA,Sports Arena,General,1.1,W/ft2,,,,,,, -BA,Town Hall,General,1.1,W/ft2,,,,,,, -BA,Transportation,General,1,W/ft2,,,,,,, -BA,Warehouse,General,0.8,W/ft2,,,,,,, -BA,Workshop,General,1.4,W/ft2,,,,,,, -CS,Office-Enclosed,General,1.1,W/ft2,,,,,,, -CS,Office-Open Plan,General,1.1,W/ft2,,,,,,, -CS,Conference/Meeting/Multipurpose,General,1.3,W/ft2,,,,,REQ,, -CS,Classroom/Lecture/Training,General,1.4,W/ft2,,,,,REQ,, -CS,Classroom/Lecture/Training,For Penitentiary,1.3,W/ft2,,,,,REQ,, -CS,Lobby,General,1.3,W/ft2,,,,,,, -CS,Lobby,For Hotel,1.1,W/ft2,,,,,,, -CS,Lobby,For Performing Arts Theater,3.3,W/ft2,,,,,,, -CS,Lobby,For Motion Picture Theater,1.1,W/ft2,,,,,,, -CS,Audience/Seating Area,General,0.9,W/ft2,,,,,,, -CS,Audience/Seating Area,For Gymnasium,0.4,W/ft2,,,,,,, -CS,Audience/Seating Area,For Exercise Center,0.3,W/ft2,,,,,,, -CS,Audience/Seating Area,For Convention Center,0.7,W/ft2,,,,,,, -CS,Audience/Seating Area,For Penitentiary,0.7,W/ft2,,,,,,, -CS,Audience/Seating Area,For Religious Buildings,1.7,W/ft2,,,,,,, -CS,Audience/Seating Area,For Sports Arena,0.4,W/ft2,,,,,,, -CS,Audience/Seating Area,For Performing Arts Theater,2.6,W/ft2,,,,,,, -CS,Audience/Seating Area,For Motion Picture Theater,1.2,W/ft2,,,,,,, -CS,Audience/Seating Area,For Transportation,0.5,W/ft2,,,,,,, -CS,Atrium: First Three Floors,General,0.6,W/ft2,,,,,,, -CS,Atrium: Each Additional Floor,General,0.2,W/ft2,,,,,,, -CS,Lounge/Recreation,General,1.2,W/ft2,,,,,REQ,, -CS,Lounge/Recreation,For Hospital,0.8,W/ft2,,,,,REQ,, -CS,Dining Area,General,0.9,W/ft2,,,,,,, -CS,Dining Area,For Penitentiary,1.3,W/ft2,,,,,,, -CS,Dining Area,For Hotel,1.3,W/ft2,,,,,,, -CS,Dining Area,For Motel,1.2,W/ft2,,,,,,, -CS,Dining Area,For Bar Lounge/Leisure Dining,1.4,W/ft2,,,,,,, -CS,Dining Area,For Family Dining,2.1,W/ft2,,,,,,, -CS,Food Preparation,General,1.2,W/ft2,,,,,,, -CS,Laboratory,General,1.4,W/ft2,,,,,,, -CS,Restrooms,General,0.9,W/ft2,,,,,,, -CS,Dressing/Locker/Fitting Room,General,0.6,W/ft2,,,,,,, -CS,Corridor/Transition,General,0.5,W/ft2,,,,,,, -CS,Corridor/Transition,For Hospital,1,W/ft2,,,,,,, -CS,Corridor/Transition,For Manufacturing Facility,0.5,W/ft2,,,,,,, -CS,Stairs: Active,General,0.6,W/ft2,,,,,,, -CS,Active Storage,General,0.8,W/ft2,,,,,,, -CS,Active Storage,For Hospital,0.9,W/ft2,,,,,,, -CS,Inactive Storage,General,0.3,W/ft2,,,,,,, -CS,Inactive Storage,For Museum,0.8,W/ft2,,,,,,, -CS,Electrical/Mechanical,General,1.5,W/ft2,,,,,,, -CS,Workshop,General,1.9,W/ft2,,,,,,, -SS,Gymnasium/Exercise Center,Playing Area,1.4,W/ft2,,,,,,, -SS,Gymnasium/Exercise Center,Exercise Area,0.9,W/ft2,,,,,,, -SS,Courthouse/Police Station/Penitentiary,Courtroom,1.9,W/ft2,,,,,,, -SS,Courthouse/Police Station/Penitentiary,Confinement Cells,0.9,W/ft2,,,,,,, -SS,Courthouse/Police Station/Penitentiary,Judges Chambers,1.3,W/ft2,,,,,,, -SS,Fire Stations,Fire Station Engine Room,0.8,W/ft2,,,,,,, -SS,Fire Stations,Sleeping Quarters,0.3,W/ft2,,,,,,, -SS,Post Office: Sorting Area,General,1.2,W/ft2,,,,,,, -SS,Convention Center: Exhibit Space,General,1.3,W/ft2,,,,,,, -SS,Library,Card File and Cataloging,1.1,W/ft2,,,,,,, -SS,Library,Stacks,1.7,W/ft2,,,,,,, -SS,Library,Reading Area,1.2,W/ft2,,,,,,, -SS,Hospital,Emergency,2.7,W/ft2,,,,,,, -SS,Hospital,Recovery,0.8,W/ft2,,,,,,, -SS,Hospital,Nurse Station,1,W/ft2,,,,,,, -SS,Hospital,Exam/Treatment,1.5,W/ft2,,,,,,, -SS,Hospital,Pharmacy,1.2,W/ft2,,,,,,, -SS,Hospital,Patient Room,0.7,W/ft2,,,,,,, -SS,Hospital,Operating Room,2.2,W/ft2,,,,,,, -SS,Hospital,Nursery,0.6,W/ft2,,,,,,, -SS,Hospital,Medical Supply,1.4,W/ft2,,,,,,, -SS,Hospital,Physical Therapy,0.9,W/ft2,,,,,,, -SS,Hospital,Radiology,0.4,W/ft2,,,,,,, -SS,Hospital,Laundry: Washing,0.6,W/ft2,,,,,,, -SS,Automotive: Service/Repair,General,0.7,W/ft2,,,,,,, -SS,Manufacturing,Low Bay (<25 ft Floor to Ceiling Height),1.2,W/ft2,,,,,,, -SS,Manufacturing,High Bay (>25 ft Floor to Ceiling Height),1.7,W/ft2,,,,,,, -SS,Manufacturing,Detailed Manufacturing,2.1,W/ft2,,,,,,, -SS,Manufacturing,Equipment Room,1.2,W/ft2,,,,,,, -SS,Manufacturing,Control Room,0.5,W/ft2,,,,,,, -SS,Hotel/Motel Guest Rooms,General,1.1,W/ft2,,,,,,, -SS,Dormitory: Living Quarters,General,1.1,W/ft2,,,,,,, -SS,Museum,General Exhibition,1,W/ft2,,,,,,, -SS,Museum,Restoration,1.7,W/ft2,,,,,,, -SS,Bank/Office Banking Activity Area,General,1.5,W/ft2,,,,,,, -SS,Religious Buildings,"Worship Pulpit, Choir",2.4,W/ft2,,,,,,, -SS,Religious Buildings,Fellowship Hall,0.9,W/ft2,,,,,,, -SS,Retail,Sales Area,1.7,W/ft2,,,,,,, -SS,Retail,Mall Concourse,1.7,W/ft2,,,,,,, -SS,Sports Arena,Ring Sports Area,2.7,W/ft2,,,,,,, -SS,Sports Arena,Court Sports Area,2.3,W/ft2,,,,,,, -SS,Sports Arena,Indoor Playing Field Area,1.4,W/ft2,,,,,,, -SS,Warehouse,Fine Material Storage,1.4,W/ft2,,,,,,, -SS,Warehouse,Medium/Bulky Material Storage,0.9,W/ft2,,,,,,, -SS,Parking Garage: Garage Area,General,0.2,W/ft2,,,,,,, -SS,Transportation,Airport: Concourse,0.6,W/ft2,,,,,,, -SS,Transportation,Air/Train/Bus: Baggage Area,1,W/ft2,,,,,,, -SS,Transportation,Terminal: Ticket Counter,1.5,W/ft2,,,,,,, -SS,Retail,Sales Additional (Specific Display),1.6,W/ft2,,,,,,, -SS,Retail,Sales Additional (Valuable Merchandise),3.9,W/ft2,,,,,,, -SS,None,None,0,W/ft2,,,,,,, diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2007.csv b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2007.csv deleted file mode 100644 index 7f0f555710..0000000000 --- a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2007.csv +++ /dev/null @@ -1,130 +0,0 @@ -method,lighting_primary_space_type,lighting_secondary_space_type,lighting_power_density,unit,rcr_threshold,automatic_daylight_responsive_controls_for_sidelighting,automatic_daylight_responsive_controls_for_toplighting,automatic_partial_off,automatic_full_off,scheduled_shutoff,annotation -BA,Automotive Facility,General,0.9,W/ft2,,,,,,, -BA,Convention Center,General,1.2,W/ft2,,,,,,, -BA,Courthouse,General,1.2,W/ft2,,,,,,, -BA,Dining: Bar Lounge/leisure,General,1.3,W/ft2,,,,,,, -BA,Dining: Cafeteria/fast Food,General,1.4,W/ft2,,,,,,, -BA,Dining: Family,General,1.6,W/ft2,,,,,,, -BA,Dormitory,General,1,W/ft2,,,,,,, -BA,Exercise Center,General,1,W/ft2,,,,,,, -BA,Gymnasium,General,1.1,W/ft2,,,,,,, -BA,Health-care Clinic,General,1,W/ft2,,,,,,, -BA,Hospital,General,1.2,W/ft2,,,,,,, -BA,Hotel,General,1,W/ft2,,,,,,, -BA,Library,General,1.3,W/ft2,,,,,,, -BA,Manufacturing Facility,General,1.3,W/ft2,,,,,,, -BA,Motel,General,1,W/ft2,,,,,,, -BA,Motion Picture Theater,General,1.2,W/ft2,,,,,,, -BA,Multifamily,General,0.7,W/ft2,,,,,,, -BA,Museum,General,1.1,W/ft2,,,,,,, -BA,Office,General,1,W/ft2,,,,,,, -BA,Parking Garage,General,0.3,W/ft2,,,,,,, -BA,Penitentiary,General,1,W/ft2,,,,,,, -BA,Performing Arts Theater,General,1.6,W/ft2,,,,,,, -BA,Police/fire Station,General,1,W/ft2,,,,,,, -BA,Post Office,General,1.1,W/ft2,,,,,,, -BA,Religious Building,General,1.3,W/ft2,,,,,,, -BA,Retail,General,1.5,W/ft2,,,,,,, -BA,School/University,General,1.2,W/ft2,,,,,,, -BA,Sports Arena,General,1.1,W/ft2,,,,,,, -BA,Town Hall,General,1.1,W/ft2,,,,,,, -BA,Transportation,General,1,W/ft2,,,,,,, -BA,Warehouse,General,0.8,W/ft2,,,,,,, -BA,Workshop,General,1.4,W/ft2,,,,,,, -CS,Dining Area,For Bar Lounge/Leisure Dining,1.4,W/ft2,,,,,,, -CS,Audience/seating Area,For Convention Center,0.7,W/ft2,,,,,,, -CS,Dining Area,For Family Dining,2.1,W/ft2,,,,,,, -CS,Audience/seating Area,For Exercise Center,0.3,W/ft2,,,,,,, -CS,Active Storage,For Hospital,0.9,W/ft2,,,,,,, -CS,Corridor/transition,For Hospital,1,W/ft2,,,,,,, -CS,Lounge/Recreation,For Hospital,0.8,W/ft2,,,,,REQ,, -CS,Dining Area,For Hotel,1.3,W/ft2,,,,,,, -CS,Lobby,For Hotel,1.1,W/ft2,,,,,,, -CS,Corridor/transition,For Manufacturing Facility,0.5,W/ft2,,,,,,, -CS,Dining Area,For Motel,1.2,W/ft2,,,,,,, -CS,Audience/seating Area,General,0.9,W/ft2,,,,,,, -CS,Lobby,For Motion Picture Theater,1.1,W/ft2,,,,,,, -CS,Inactive Storage,For Museum,0.8,W/ft2,,,,,,, -CS,Classroom/Lecture/Training,For Penitentiary,1.3,W/ft2,,,,,REQ,, -CS,Dining Area,For Penitentiary,1.3,W/ft2,,,,,,, -CS,Audience/seating Area,For Gymnasium,0.4,W/ft2,,,,,,, -CS,Lobby,For Performing Arts Theater,3.3,W/ft2,,,,,,, -CS,Audience/seating Area,For Motion Picture Theater,1.2,W/ft2,,,,,,, -CS,Active Storage,General,0.8,W/ft2,,,,,,, -CS,Atrium each Additional Floor,General,0.2,W/ft2,,,,,,, -CS,Atrium first Three Floors,General,0.6,W/ft2,,,,,,, -CS,Classroom/Lecture/Training,General,1.4,W/ft2,,,,,REQ,, -CS,Conference/Meeting/Multipurpose,General,1.3,W/ft2,,,,,REQ,, -CS,Corridor/transition,General,0.5,W/ft2,,,,,,, -CS,Dining Area,General,0.9,W/ft2,,,,,,, -CS,Dressing/Locker/Fitting Room,General,0.6,W/ft2,,,,,,, -CS,Electrical/Mechanical,General,1.5,W/ft2,,,,,,, -CS,Food Preparation,General,1.2,W/ft2,,,,,,, -CS,Inactive Storage,General,0.3,W/ft2,,,,,,, -CS,Laboratory,General,1.4,W/ft2,,,,,,, -CS,Lobby,General,1.3,W/ft2,,,,,,, -CS,Lounge/Recreation,General,1.2,W/ft2,,,,,REQ,, -CS,Office-Enclosed,General,1.1,W/ft2,,,,,,, -CS,Office-Open Plan,General,1.1,W/ft2,,,,,,, -CS,Restrooms,General,0.9,W/ft2,,,,,,, -CS,Sales Area,General,1.7,W/ft2,,,,,,, -CS,Audience/seating Area,For Penitentiary,0.7,W/ft2,,,,,,, -CS,Stairs active,General,0.6,W/ft2,,,,,,, -CS,Workshop,General,1.9,W/ft2,,,,,,, -CS,Audience/seating Area,For Performing Arts Theater,2.6,W/ft2,,,,,,, -CS,Audience/seating Area,For Religious Buildings,1.7,W/ft2,,,,,,, -CS,Audience/seating Area,For Sports Arena,0.4,W/ft2,,,,,,, -CS,Audience/seating Area,For Transportation,0.5,W/ft2,,,,,,, -SS,Transportation,Air/Train/Bus Baggage Area,1,W/ft2,,,,,,, -SS,Transportation,Airport Concourse,0.6,W/ft2,,,,,,, -SS,Library,Card File and Cataloging,1.1,W/ft2,,,,,,, -SS,Courthouse/Police Station/Penitentiary,Confinement Cells,0.9,W/ft2,,,,,,, -SS,Manufacturing,Control Room,0.5,W/ft2,,,,,,, -SS,Sports Arena,Court Sports Area,2.3,W/ft2,,,,,,, -SS,Courthouse/Police Station/Penitentiary,Courtroom,1.9,W/ft2,,,,,,, -SS,Manufacturing,Detailed Manufacturing,2.1,W/ft2,,,,,,, -SS,Hospital,Emergency,2.7,W/ft2,,,,,,, -SS,Fire Stations,Engine Room,0.8,W/ft2,,,,,,, -SS,Manufacturing,Equipment Room,1.2,W/ft2,,,,,,, -SS,Hospital,Exam/Treatment,1.5,W/ft2,,,,,,, -SS,Gymnasium/exercise Center,Exercise Area,0.9,W/ft2,,,,,,, -SS,Religious Buildings,Fellowship Hall,0.9,W/ft2,,,,,,, -SS,Warehouse,Fine Material Storage,1.4,W/ft2,,,,,,, -SS,Automotive service/repair,General,0.7,W/ft2,,,,,,, -SS,Bank/Office Banking Activity Area,General,1.5,W/ft2,,,,,,, -SS,Convention Center exhibit Space,General,1.3,W/ft2,,,,,,, -SS,Dormitory living Quarters,General,1.1,W/ft2,,,,,,, -SS,Hotel/motel Guest Rooms,General,1.1,W/ft2,,,,,,, -SS,Parking Garage garage Area,General,0.2,W/ft2,,,,,,, -SS,Post Office sorting Area,General,1.2,W/ft2,,,,,,, -SS,Museum,General Exhibition,1,W/ft2,,,,,,, -SS,Manufacturing,High Bay (>25 ft Floor to Ceiling Height),1.7,W/ft2,,,,,,, -SS,Sports Arena,Indoor Playing Field Area,1.4,W/ft2,,,,,,, -SS,Courthouse/Police Station/Penitentiary,Judges Chambers,1.3,W/ft2,,,,,,, -SS,Hospital,Laundry Washing,0.6,W/ft2,,,,,,, -SS,Manufacturing,Low Bay (<25 ft Floor to Ceiling Height),1.2,W/ft2,,,,,,, -SS,Retail,Mall Concourse,1.7,W/ft2,,,,,,, -SS,Hospital,Medical Supply,1.4,W/ft2,,,,,,, -SS,Warehouse,Medium/Bulky Material Storage,0.9,W/ft2,,,,,,, -SS,Hospital,Nurse Station,1,W/ft2,,,,,,, -SS,Hospital,Nursery,0.6,W/ft2,,,,,,, -SS,Hospital,Operating Room,2.2,W/ft2,,,,,,, -SS,Hospital,Patient Room,0.7,W/ft2,,,,,,, -SS,Hospital,Pharmacy,1.2,W/ft2,,,,,,, -SS,Hospital,Physical Therapy,0.9,W/ft2,,,,,,, -SS,Gymnasium/exercise Center,Playing Area,1.4,W/ft2,,,,,,, -SS,Hospital,Radiology,0.4,W/ft2,,,,,,, -SS,Library,Reading Area,1.2,W/ft2,,,,,,, -SS,Hospital,Recovery,0.8,W/ft2,,,,,,, -SS,Museum,Restoration,1.7,W/ft2,,,,,,, -SS,Sports Arena,Ring Sports Area,2.7,W/ft2,,,,,,, -SS,Retail,Sales Additional (Type 1),1,W/ft2,,,,,,, -SS,Retail,Sales Additional (Type 2),1.7,W/ft2,,,,,,, -SS,Retail,Sales Additional (Type 3),2.6,W/ft2,,,,,,, -SS,Retail,Sales Additional (Type 4),4.2,W/ft2,,,,,,, -SS,Retail,Sales Area,1.7,W/ft2,,,,,,, -SS,Fire Stations,Sleeping Quarters,0.3,W/ft2,,,,,,, -SS,Library,Stacks,1.7,W/ft2,,,,,,, -SS,Transportation,Terminal Ticket Counter,1.5,W/ft2,,,,,,, -SS,Religious Buildings,"Worship Pulpit, Choir",2.4,W/ft2,,,,,,, -SS,None,None,0,W/ft2,,,,,,, diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2010.csv b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2010.csv deleted file mode 100644 index 025d0ceab6..0000000000 --- a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2010.csv +++ /dev/null @@ -1,134 +0,0 @@ -method,lighting_primary_space_type,lighting_secondary_space_type,lighting_power_density,unit,rcr_threshold,automatic_daylight_responsive_controls_for_sidelighting,automatic_daylight_responsive_controls_for_toplighting,automatic_partial_off,automatic_full_off,scheduled_shutoff,annotation -BA,Automotive Facility,General,0.82,W/ft2,,REQ,REQ,,,, -BA,Convention Center,General,1.08,W/ft2,,REQ,REQ,,,, -BA,Courthouse,General,1.05,W/ft2,,REQ,REQ,,,, -BA,Dining: Bar Lounge/Leisure,General,0.99,W/ft2,,REQ,REQ,,,, -BA,Dining: Cafeteria/Fast Food,General,0.9,W/ft2,,REQ,REQ,,,, -BA,Dining: Family,General,0.89,W/ft2,,REQ,REQ,,,, -BA,Dormitory,General,0.61,W/ft2,,REQ,REQ,,,, -BA,Exercise Center,General,0.88,W/ft2,,REQ,REQ,,,, -BA,Fire Stations,General,0.71,W/ft2,,REQ,REQ,,,, -BA,Gymnasium,General,1,W/ft2,,REQ,REQ,,,, -BA,Health-care Clinic,General,0.87,W/ft2,,REQ,REQ,,,, -BA,Hospital,General,1.21,W/ft2,,REQ,REQ,,REQ,, -BA,Hotel,General,1,W/ft2,,REQ,REQ,,,, -BA,Library,General,1.18,W/ft2,,REQ,REQ,,,, -BA,Manufacturing Facility,General,1.11,W/ft2,,REQ,REQ,,,, -BA,Motel,General,0.88,W/ft2,,REQ,REQ,,,, -BA,Motion Picture Theater,General,0.83,W/ft2,,REQ,REQ,,,, -BA,Multifamily,General,0.6,W/ft2,,REQ,REQ,,,, -BA,Museum,General,1.06,W/ft2,,REQ,REQ,,,, -BA,Office,General,0.9,W/ft2,,REQ,REQ,,,, -BA,Parking Garage,General,0.25,W/ft2,,REQ,REQ,,,, -BA,Penitentiary,General,0.97,W/ft2,,REQ,REQ,,,, -BA,Performing Arts Theater,General,1.39,W/ft2,,REQ,REQ,,,, -BA,Police Station,General,0.96,W/ft2,,REQ,REQ,,,, -BA,Post Office,General,0.87,W/ft2,,REQ,REQ,,,, -BA,Religious Building,General,1.05,W/ft2,,REQ,REQ,,,, -BA,Retail,General,1.4,W/ft2,,REQ,REQ,,,, -BA,School/University,General,0.99,W/ft2,,REQ,REQ,,,, -BA,Sports Arena,General,0.78,W/ft2,,REQ,REQ,,,, -BA,Town Hall,General,0.92,W/ft2,,REQ,REQ,,,, -BA,Transportation,General,0.77,W/ft2,,REQ,REQ,,,, -BA,Warehouse,General,0.66,W/ft2,,REQ,REQ,,,, -BA,Workshop,General,1.2,W/ft2,,REQ,REQ,,,, -CS,Audience/seating Area permanent,For auditorium,0.79,W/ft2,6,REQ,REQ,,,, -CS,Office,Enclosed,1.1,W/ft2,8,REQ,REQ,,REQ,, -CS,Atrium,First 40 ft in height,0.03,W/ft,,REQ,REQ,,,, -CS,Dining Area,For Bar Lounge/Leisure Dining,1.31,W/ft2,4,REQ,REQ,,,, -CS,Laboratory,For Classrooms,1.28,W/ft2,6,REQ,REQ,,,, -CS,Lobby,For Elevator,0.64,W/ft2,6,REQ,REQ,,,, -CS,Dining Area,For Family Dining,0.89,W/ft2,4,REQ,REQ,,,, -CS,Laboratory,For Medical/Industrial/Research,1.81,W/ft2,6,REQ,REQ,,,, -CS,Lobby,For Motion Picture Theater,0.52,W/ft2,4,REQ,REQ,,,, -CS,Lobby,For Performing Arts Theater,2,W/ft2,6,REQ,REQ,,,, -CS,Audience/seating Area permanent,For Motion Picture Theater,1.14,W/ft2,4,REQ,REQ,,,, -CS,Classroom/Lecture/Training,General,1.24,W/ft2,4,REQ,REQ,,REQ,, -CS,Conference/Meeting/Multipurpose,General,1.23,W/ft2,6,REQ,REQ,,REQ,, -CS,Corridor/Transition,General,0.66,W/ft2,,REQ,REQ,,,,rcr_threshold: width<8 ft -CS,Dining Area,General,0.65,W/ft2,4,REQ,REQ,,,, -CS,Dressing/Fitting Room For Performing Arts Theater,General,0.4,W/ft2,6,REQ,REQ,,,, -CS,Electrical/Mechanical,General,0.95,W/ft2,6,REQ,REQ,,,, -CS,Food Preparation,General,0.99,W/ft2,6,REQ,REQ,,,, -CS,Lobby,General,0.9,W/ft2,4,REQ,REQ,,,, -CS,Locker Room,General,0.75,W/ft2,6,REQ,REQ,,REQ,, -CS,Lounge/Recreation,General,0.73,W/ft2,4,REQ,REQ,,REQ,, -CS,Restrooms,General,0.98,W/ft2,8,REQ,REQ,,REQ,, -CS,Sales Area,General,1.68,W/ft2,6,REQ,REQ,,,, -CS,Stairway,General,0.69,W/ft2,10,REQ,REQ,REQ,,, -CS,Storage,General,0.63,W/ft2,6,REQ,REQ,,REQ,, -CS,Workshop,General,1.59,W/ft2,6,REQ,REQ,,,, -CS,Atrium,Height above 40 ft,0.02,W/ft,,REQ,REQ,,,, -CS,Audience/seating Area permanent,For Performing Arts Theater,2.43,W/ft2,8,REQ,REQ,,,, -CS,Office,Open Plan,0.98,W/ft2,4,REQ,REQ,,,, -SS,Transportation,Air/Train/Bus Baggage Area,0.76,W/ft2,4,REQ,REQ,,,, -SS,Transportation,Airport Concourse,0.36,W/ft2,4,REQ,REQ,,,, -SS,Convention Center,Audience Seating,0.82,W/ft2,4,REQ,REQ,,,, -SS,Religious Buildings,Audience Seating,1.53,W/ft2,4,REQ,REQ,,,, -SS,Sports Arena,Audience Seating,0.43,W/ft2,4,REQ,REQ,,,, -SS,Transportation,Audience Seating,0.54,W/ft2,4,REQ,REQ,,,, -SS,Bank/Office,Banking Activity Area,1.38,W/ft2,6,REQ,REQ,,,, -SS,Library,Card File and Cataloging,0.72,W/ft2,4,REQ,REQ,,,, -SS,Courthouse/Police Station/Penitentiary,Confinement Cells,1.1,W/ft2,6,REQ,REQ,,,, -SS,Hospital,Corridor/Transition,0.89,W/ft2,,REQ,REQ,,,,rcr_threshold: width<8 ft -SS,Manufacturing,Corridor/Transition,0.41,W/ft2,,REQ,REQ,,,,rcr_threshold: width<8 ft -SS,Sports Arena,Court Sports Arena Class 1,3.01,W/ft2,4,REQ,REQ,,,, -SS,Sports Arena,Court Sports Arena Class 2,1.92,W/ft2,4,REQ,REQ,,,, -SS,Sports Arena,Court Sports Arena Class 3,1.2,W/ft2,4,REQ,REQ,,,, -SS,Sports Arena,Court Sports Arena Class 4,0.72,W/ft2,4,REQ,REQ,,,, -SS,Courthouse/Police Station/Penitentiary,Courtroom,1.72,W/ft2,6,REQ,REQ,,,, -SS,Manufacturing,Detailed Manufacturing,1.29,W/ft2,4,REQ,REQ,,,, -SS,Retail,Dressing/Fitting Room,0.87,W/ft2,8,REQ,REQ,,,, -SS,Hospital,Emergency,2.26,W/ft2,6,REQ,REQ,,,, -SS,Fire Stations,Engine Room,0.56,W/ft2,4,REQ,REQ,,,, -SS,Manufacturing,Equipment Room,0.95,W/ft2,6,REQ,REQ,,,, -SS,Hospital,Exam/Treatment,1.66,W/ft2,8,REQ,REQ,,,, -SS,Gymnasium/fitness Center,Exercise Area,0.72,W/ft2,4,REQ,REQ,,,, -SS,Convention Center,Exhibit Space,1.45,W/ft2,4,REQ,REQ,,,, -SS,Manufacturing,Extra High Bay (>50 ft Floor to Ceiling Height),1.05,W/ft2,4,REQ,REQ,,,, -SS,Religious Buildings,Fellowship Hall,0.64,W/ft2,4,REQ,REQ,,,, -SS,Warehouse,Fine Material Storage,0.95,W/ft2,6,REQ,REQ,,,, -SS,Parking Garage,Garage Area,0.19,W/ft2,4,REQ,REQ,,,, -SS,Post Office Sorting Area,General,0.94,W/ft2,4,REQ,REQ,,,, -SS,Museum,General Exhibition,1.05,W/ft2,6,REQ,REQ,,,, -SS,Gymnasium/fitness Center,Gymnasium Audience Seating,0.43,W/ft2,6,REQ,REQ,,,, -SS,Manufacturing,High Bay (25-50 ft Floor to Ceiling Height),1.23,W/ft2,4,REQ,REQ,,,, -SS,Hotel/Highway Lodging,Highway Lodging Dining,0.88,W/ft2,4,REQ,REQ,,,, -SS,Hotel/Highway Lodging,Highway Lodging Guest Rooms,0.75,W/ft2,6,REQ,REQ,,,, -SS,Hotel/Highway Lodging,Hotel Dining,0.82,W/ft2,4,REQ,REQ,,,, -SS,Hotel/Highway Lodging,Hotel Guest Rooms,1.11,W/ft2,6,REQ,REQ,,,, -SS,Hotel/Highway Lodging,Hotel Lobby,1.06,W/ft2,4,REQ,REQ,,,, -SS,Courthouse/Police Station/Penitentiary,Judges' Chambers,1.17,W/ft2,8,REQ,REQ,,,, -SS,Hospital,Laundry/Washing,0.6,W/ft2,4,REQ,REQ,,,, -SS,Dormitory,Living Quarters,0.38,W/ft2,8,REQ,REQ,,,, -SS,Hospital,Lounge/Recreation,1.07,W/ft2,6,REQ,REQ,,REQ,, -SS,Manufacturing,Low Bay (<25 ft Floor to Ceiling Height),1.19,W/ft2,4,REQ,REQ,,,, -SS,Retail,Mall Concourse,1.1,W/ft2,4,REQ,REQ,,,, -SS,Hospital,Medical Supply,1.27,W/ft2,6,REQ,REQ,,REQ,, -SS,Warehouse,Medium/Bulky Material Storage,0.58,W/ft2,4,REQ,REQ,,,, -SS,Hospital,Nursery,0.88,W/ft2,6,REQ,REQ,,,, -SS,Hospital,Nurses' Station,0.87,W/ft2,6,REQ,REQ,,,, -SS,Hospital,Operating Room,1.89,W/ft2,6,REQ,REQ,,,, -SS,Hospital,Patient Room,0.62,W/ft2,6,REQ,REQ,,,, -SS,Courthouse/Police Station/Penitentiary,Penitentiary Audience Seating,0.43,W/ft2,4,REQ,REQ,,,, -SS,Courthouse/Police Station/Penitentiary,Penitentiary Classroom,1.34,W/ft2,4,REQ,REQ,,REQ,, -SS,Courthouse/Police Station/Penitentiary,Penitentiary Dining,1.07,W/ft2,6,REQ,REQ,,,, -SS,Hospital,Pharmacy,1.14,W/ft2,6,REQ,REQ,,,, -SS,Hospital,Physical Therapy,0.91,W/ft2,6,REQ,REQ,,,, -SS,Gymnasium/fitness Center,Playing Area,1.2,W/ft2,4,REQ,REQ,,,, -SS,Hospital,Radiology/Imaging,1.32,W/ft2,6,REQ,REQ,,,, -SS,Library,Reading Area,0.93,W/ft2,4,REQ,REQ,,,, -SS,Hospital,Recovery,1.15,W/ft2,6,REQ,REQ,,,, -SS,Museum,Restoration,1.02,W/ft2,6,REQ,REQ,,,, -SS,Sports Arena,Ring Sports Area,2.68,W/ft2,4,REQ,REQ,,,, -SS,Retail,Sales Additional (Type 1),0.6,W/ft2,6,,REQ,,,, -SS,Retail,Sales Additional (Type 2),0.6,W/ft2,6,,REQ,,,, -SS,Retail,Sales Additional (Type 3),1.4,W/ft2,6,,REQ,,,, -SS,Retail,Sales Additional (Type 4),2.5,W/ft2,6,,REQ,,,, -SS,Retail,Sales Area,1.68,W/ft2,6,,REQ,,,, -SS,Automotive,Service/Repair,0.67,W/ft2,4,REQ,REQ,,,, -SS,Fire Stations,Sleeping Quarters,0.25,W/ft2,6,REQ,REQ,,,, -SS,Library,Stacks,1.71,W/ft2,4,REQ,REQ,,,, -SS,Transportation,Terminal Ticket Counter,1.08,W/ft2,4,REQ,REQ,,,, -SS,Religious Buildings,"Worship Pulpit, Choir",1.53,W/ft2,4,REQ,REQ,,,, -SS,None,None,0,W/ft2,,,,,,, diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2013.csv b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2013.csv deleted file mode 100644 index f534ce6f32..0000000000 --- a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2013.csv +++ /dev/null @@ -1,144 +0,0 @@ -method,lighting_primary_space_type,lighting_secondary_space_type,lighting_power_density,unit,rcr_threshold,automatic_daylight_responsive_controls_for_sidelighting,automatic_daylight_responsive_controls_for_toplighting,automatic_partial_off,automatic_full_off,scheduled_shutoff,annotation -BA,Automotive Facility,General,0.8,W/ft2,,,,,,, -BA,Convention Center,General,1.01,W/ft2,,,,,,, -BA,Courthouse,General,1.01,W/ft2,,,,,,, -BA,Dining: Bar Lounge/leisure,General,1.01,W/ft2,,,,,,, -BA,Dining: Cafeteria/fast Food,General,0.9,W/ft2,,,,,,, -BA,Dining: Family,General,0.95,W/ft2,,,,,,, -BA,Dormitory,General,0.57,W/ft2,,,,,,, -BA,Exercise Center,General,0.84,W/ft2,,,,,,, -BA,Fire Station,General,0.671,W/ft2,,,,,,, -BA,Gymnasium,General,0.94,W/ft2,,,,,,, -BA,Health-care Clinic,General,0.9,W/ft2,,,,,,, -BA,Hospital,General,1.05,W/ft2,,,,,,, -BA,Hotel/motel,General,0.87,W/ft2,,,,,,, -BA,Library,General,1.19,W/ft2,,,,,,, -BA,Manufacturing Facility,General,1.17,W/ft2,,,,,,, -BA,Motion Picture Theater,General,0.76,W/ft2,,,,,,, -BA,Multifamily,General,0.51,W/ft2,,,,,,, -BA,Museum,General,1.02,W/ft2,,,,,,, -BA,Office,General,0.82,W/ft2,,,,,,, -BA,Parking Garage,General,0.21,W/ft2,,,,,,, -BA,Penitentiary,General,0.81,W/ft2,,,,,,, -BA,Performing Arts Theater,General,1.39,W/ft2,,,,,,, -BA,Police Station,General,0.87,W/ft2,,,,,,, -BA,Post Office,General,0.87,W/ft2,,,,,,, -BA,Religious Building,General,1,W/ft2,,,,,,, -BA,Retail,General,1.26,W/ft2,,,,,,, -BA,School/University,General,0.87,W/ft2,,,,,,, -BA,Sports Arena,General,0.91,W/ft2,,,,,,, -BA,Town Hall,General,0.89,W/ft2,,,,,,, -BA,Transportation,General,0.7,W/ft2,,,,,,, -BA,Warehouse,General,0.66,W/ft2,,,,,,, -BA,Workshop,General,1.19,W/ft2,,,,,,, -CS,Atrium,<20 ft in height,0.03,W/ft,,REQ,REQ,,ADD2,ADD2,LP-Height -CS,Storage Room,<50 ft2,1.24,W/ft2,6,,,,ADD2,ADD2, -CS,Atrium,>40 ft in height,0.4,W/ft2,,REQ,REQ,,ADD2,ADD2,LP-Height; + 0.02W/ft -CS,Atrium,gt 20 ft and lt40 ft in height,0.03,W/ft,,REQ,REQ,,ADD2,ADD2,LP-Height -CS,Storage Room,gt 50 ft2 and lt 1000 ft2,0.63,W/ft2,6,REQ,REQ,,REQ,, -CS,Audience/seating Area,all other audience seating areas,0.43,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Classroom/Lecture Hall/Training Room,all other classrooms/lecture halls/training rooms,1.24,W/ft2,4,REQ,REQ,,REQ,, -CS,Corridor,all other corridors,0.66,W/ft2,,REQ,REQ,REQ,ADD2,ADD2,rcr_threshold: width<8 ft -CS,Dining Area,all other dining areas,0.65,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Laboratory,all other laboratories,1.81,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Lobby,all other lobbies,0.9,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, -CS,Lounge/Breakroom,all other lounges/breakrooms,0.73,W/ft2,4,REQ,REQ,,REQ,, -CS,Restroom,all other restrooms,0.98,W/ft2,8,REQ,REQ,,REQ,, -CS,Storage Room,all other storage rooms,0.63,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, -CS,Office,enclosed and >250 ft2,1.11,W/ft2,8,REQ,REQ,,ADD2,, -CS,Office,enclosed and lt 250 ft2,1.11,W/ft2,8,REQ,REQ,,REQ,, -CS,Lobby,for an elevator,0.64,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Audience/seating Area,in an auditorium,0.63,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Audience/seating Area,in a convention center,0.82,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,"Seating Area, General",General,0.54,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Audience/seating Area,in a gymnasium,0.65,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Audience/seating Area,in a motion picture theater,1.14,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Banking Activity Area,General,1.01,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Breakroom,General,0.73,W/ft2,4,REQ,REQ,,REQ,, -CS,Computer Room,General,1.71,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Conference/meeting/multipurpose Room,General,1.23,W/ft2,6,REQ,REQ,,REQ,, -CS,Confinement Cells,General,0.81,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Copy/Print Room,General,0.72,W/ft2,6,REQ,REQ,,REQ,, -CS,Courtroom,General,1.72,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Electrical/Mechanical Room,General,0.42,W/ft2,6,REQ,REQ,,,, -CS,Emergency Vehicle Garage,General,0.56,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Food Preparation Area,General,1.21,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Guest Room,General,0.91,W/ft2,6,,,,REQ,,See Section 9.4.1.3b -CS,Laundry/Washing Area,General,0.6,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,"Loading Dock, Interior",General,0.47,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Locker Room,General,0.75,W/ft2,6,REQ,REQ,,REQ,, -CS,"Parking Area, Interior",General,0.19,W/ft2,4,,,REQ,,,See Section 9.4.1.2 -CS,Pharmacy Area,General,1.68,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Sales Area,General,1.44,W/ft2,6,,REQ,,ADD2,ADD2, -CS,Audience/seating Area,in a penitentiary,0.28,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Stairway,General,0.69,W/ft2,10,REQ,REQ,REQ,ADD2,ADD2, -CS,Stairwell,General,0.69,W/ft2,10,REQ,REQ,REQ,ADD2,ADD2, -CS,Vehicular Maintenance Area,General,0.67,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Workshop,General,1.59,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Dining Area,in a facility for the visually impaired (and not used primarily by staff),2.65,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Corridor,in a facility for the visually impaired (and not used primarily by the staff),0.92,W/ft2,,REQ,REQ,REQ,ADD2,ADD2,rcr_threshold: width<8 ft -CS,Lobby,in a facility for the visually impaired (and not used primarily by the staff),1.8,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, -CS,Restroom,in a facility for the visually impaired (and not used primarily by the staff),1.21,W/ft2,8,REQ,REQ,,REQ,, -CS,Lounge/Breakroom,in a healthcare facility,0.92,W/ft2,6,REQ,REQ,,REQ,, -CS,Corridor,in a hospital,0.99,W/ft2,,REQ,REQ,ADD2,ADD2,ADD2,rcr_threshold: width<8 ft -CS,Lobby,in a hotel,1.06,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Corridor,in a manufacturing facility,0.41,W/ft2,,REQ,REQ,,ADD2,ADD2,rcr_threshold: width<8 ft -CS,Lobby,in a motion picture theater,0.59,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Audience/seating Area,in a performing arts theater,2.43,W/ft2,8,REQ,REQ,,ADD2,ADD2, -CS,Classroom/Lecture Hall/Training Room,in a penitentiary,1.34,W/ft2,4,REQ,REQ,,REQ,, -CS,Dining Area,in a penitentiary,0.96,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Lobby,in a performing arts theater,2,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, -CS,Dining Area,in bar/lounge or leisure dining,1.07,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Dining Area,in cafeteria or fast food dining,0.65,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Dining Area,in family dining,0.89,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Laboratory,in or as a classroom,1.43,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, -CS,Audience/seating Area,in a religious building,1.53,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Office,open plan,0.98,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Audience/seating Area,in a sports arena,0.43,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Religious Buildings,a worship/pulpit/choir area,1.53,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Transportation Facility,at a terminal ticket counter,0.8,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Sports Arena Playing Area,for a Class I facility,3.68,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Sports Arena Playing Area,for a Class II facility,2.4,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Sports Arena Playing Area,for a Class III facility,1.8,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Sports Arena Playing Area,for a Class IV facility,1.2,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Warehouse storage Area,"for medium to bulky, palletized items",0.58,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, -SS,Warehouse storage Area,"for smaller, hand-carried items",0.95,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, -SS,Automotive,General,0.67,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Convention Center Exhibit Space,General,1.45,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Dormitory Living Quarters,General,0.38,W/ft2,8,,,,,, -SS,Fire Station Sleeping Quarters,General,0.22,W/ft2,6,,,,,, -SS,Performing Arts Theater Dressing Room,General,0.61,W/ft2,6,REQ,REQ,,REQ,, -SS,Post Office Sorting Area,General,0.94,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, -SS,Transportation Facility,in a baggage/carousel area,0.53,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Facility For The Visually Impaired,in a chapel (used primarily by residents),2.21,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Manufacturing Facility,in a detailed manufacturing area,1.29,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Retail Facilities,in a dressing/fitting room,0.71,W/ft2,8,REQ,REQ,,REQ,, -SS,Religious Buildings,in a fellowship hall,0.64,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Museum,in a general exhibition area,1.05,W/ft2,6,REQ,REQ,,ADD2,ADD2, -SS,Manufacturing Facility,in a high bay area (25 50 ft floor-to-ceiling height),1.23,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Manufacturing Facility,in a low bay area (<25 ft floor-to-ceiling height),1.19,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Retail Facilities,in a mall concourse,1.1,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Healthcare Facility,in a medical supply room,0.74,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, -SS,Healthcare Facility,in a nurse s station,0.71,W/ft2,6,REQ,REQ,,ADD2,ADD2, -SS,Healthcare Facility,in a nursery,0.88,W/ft2,6,REQ,REQ,,ADD2,ADD2, -SS,Healthcare Facility,in a patient room,0.62,W/ft2,6,REQ,REQ,,ADD2,ADD2, -SS,Healthcare Facility,in a physical therapy room,0.91,W/ft2,6,REQ,REQ,,ADD2,ADD2, -SS,Gymnasium/fitness Center,in a playing area,1.2,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Library,in a reading area,1.06,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Healthcare Facility,in a recovery room,1.15,W/ft2,6,REQ,REQ,,ADD2,ADD2, -SS,Facility For The Visually Impaired,in a recreation room/common living room (and not used primarily by staff),2.41,W/ft2,6,,,,,, -SS,Facility For The Visually Impaired,in a recreation room/common living room (and not used primarily by staff),2.41,W/ft2,6,,,,,, -SS,Museum,in a restoration room,1.02,W/ft2,6,REQ,REQ,,ADD2,ADD2, -SS,Transportation Facility,in an airport concourse,0.36,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Manufacturing Facility,in an equipment room,0.74,W/ft2,6,REQ,REQ,,ADD2,ADD2, -SS,Healthcare Facility,in an exam/treatment room,1.66,W/ft2,8,REQ,REQ,,ADD2,ADD2, -SS,Gymnasium/fitness Center,in an exercise area,0.72,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Manufacturing Facility,in an extra high bay area (>50 ft floor-to-ceiling height),1.05,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Healthcare Facility,in an imaging room,1.51,W/ft2,6,,,,ADD2,ADD2, -SS,Healthcare Facility,in an operating room,2.48,W/ft2,6,,,,ADD2,ADD2, -SS,Library,in the stacks,1.71,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, -SS,Retail,Sales Additional (Type 1),0.6,W/ft2,4,REQ,REQ,,,, -SS,Retail,Sales Additional (Type 2),0.6,W/ft2,4,REQ,REQ,,,, -SS,Retail,Sales Additional (Type 3),1.4,W/ft2,4,REQ,REQ,,,, -SS,Retail,Sales Additional (Type 4),2.5,W/ft2,4,REQ,REQ,,,, -SS,None,None,0,W/ft2,,,,,,, diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.csv b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.csv deleted file mode 100644 index 3fda2e7735..0000000000 --- a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.csv +++ /dev/null @@ -1,143 +0,0 @@ -method,lighting_primary_space_type,lighting_secondary_space_type,lighting_power_density,unit,rcr_threshold,automatic_daylight_responsive_controls_for_sidelighting,automatic_daylight_responsive_controls_for_toplighting,automatic_partial_off,automatic_full_off,scheduled_shutoff,annotation -BA,Automotive Facility,General,0.71,W/ft2,,,,,,, -BA,Convention Center,General,0.76,W/ft2,,,,,,, -BA,Courthouse,General,0.9,W/ft2,,,,,,, -BA,Dining: Bar Lounge/leisure,General,0.9,W/ft2,,,,,,, -BA,Dining: Cafeteria/Fast Food,General,0.79,W/ft2,,,,,,, -BA,Dining: Family,General,0.78,W/ft2,,,,,,, -BA,Dormitory,General,0.61,W/ft2,,,,,,, -BA,Exercise Center,General,0.65,W/ft2,,,,,,, -BA,Fire Station,General,0.53,W/ft2,,,,,,, -BA,Gymnasium,General,0.68,W/ft2,,,,,,, -BA,Health-care Clinic,General,0.82,W/ft2,,,,,,, -BA,Hospital,General,1.05,W/ft2,,,,,,, -BA,Hotel/motel,General,0.75,W/ft2,,,,,,, -BA,Library,General,0.78,W/ft2,,,,,,, -BA,Manufacturing Facility,General,0.9,W/ft2,,,,,,, -BA,Motion Picture Theater,General,0.83,W/ft2,,,,,,, -BA,Multifamily,General,0.68,W/ft2,,,,,,, -BA,Museum,General,1.06,W/ft2,,,,,,, -BA,Office,General,0.79,W/ft2,,,,,,, -BA,Parking Garage,General,0.15,W/ft2,,,,,,, -BA,Penitentiary,General,0.75,W/ft2,,,,,,, -BA,Performing Arts Theater,General,1.18,W/ft2,,,,,,, -BA,Police Station,General,0.8,W/ft2,,,,,,, -BA,Post Office,General,0.67,W/ft2,,,,,,, -BA,Religious Facility,General,0.94,W/ft2,,,,,,, -BA,Retail,General,1.06,W/ft2,,,,,,, -BA,School/University,General,0.81,W/ft2,,,,,,, -BA,Sports Arena,General,0.87,W/ft2,,,,,,, -BA,Town Hall,General,0.8,W/ft2,,,,,,, -BA,Transportation,General,0.61,W/ft2,,,,,,, -BA,Warehouse,General,0.48,W/ft2,,,,,,, -BA,Workshop,General,0.9,W/ft2,,,,,,, -CS,Atrium,<20 ft in height,0.03,W/ft,,REQ,REQ,,ADD2,ADD2, -CS,Storage Room,<50 Ft2,0.97,W/ft2,6,,,,ADD2,ADD2, -CS,Atrium,>40 ft in height,0.4,W/ft2,,REQ,REQ,,ADD2,ADD2, -CS,Atrium,gt 20 ft and lt 40 ft in height,0.03,W/ft,,REQ,REQ,,ADD2,ADD2, -CS,Storage Room,gt 50 Ft2 And lt 1000 Ft2,0.46,W/ft2,6,REQ,REQ,,REQ,, -CS,Audience Seating Area,All Other Audience Seating Areas,0.43,W/ft2,4,,REQ,REQ,,ADD2,ADD2 -CS,Classroom/lecture Hall/training Room,All Other Classrooms/lecture Halls/training Rooms,0.92,W/ft2,4,REQ,REQ,,REQ,, -CS,Corridor,All Other Corridors,0.66,W/ft2,,REQ,REQ,REQ,ADD2,ADD2,rcr_threshold: width<8 ft -CS,Dining Area,All Other Dining Areas,0.63,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Laboratory,All Other Laboratories,1.45,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Lobby,All Other Lobbies,1,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, -CS,Lounge/Breakroom,All Other Lounges/breakrooms,0.62,W/ft2,4,REQ,REQ,,REQ,, -CS,Restroom,All Other Restrooms,0.85,W/ft2,8,REQ,REQ,,REQ,, -CS,Storage Room,All Other Storage Rooms,0.46,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, -CS,Audience Seating Area,Auditorium,0.63,W/ft2,6,,REQ,REQ,,ADD2,ADD2 -CS,Dining Area,Bar/lounge Or Leisure Dining,0.93,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Dining Area,Cafeteria Or Fast Food Dining,0.63,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Lobby,Elevator,0.69,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Office,Enclosed And >250 Ft2,0.93,W/ft2,8,REQ,REQ,,ADD2,ADD2, -CS,Office,Enclosed And gt 250 Ft2,0.93,W/ft2,8,REQ,REQ,,REQ,, -CS,Dining Area,Facility For The Visually Impaired (and Not Used Primarily By Staff),2,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Corridor,Facility For The Visually Impaired (and Not Used Primarily By The Staff),0.92,W/ft2,,REQ,REQ,REQ,ADD2,ADD2, -CS,Lobby,Facility For The Visually Impaired (and Not Used Primarily By The Staff),2.03,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Restroom,Facility For The Visually Impaired (and Not Used Primarily By The Staff),0.96,W/ft2,8,REQ,REQ,,REQ,, -CS,Dining Area,Family Dining,0.71,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Audience Seating Area,Convention Center,0.82,W/ft2,4,,REQ,REQ,,ADD2,ADD2 -CS,"Seating Area, General",General,0.42,W/ft2,4,,REQ,REQ,,ADD2,ADD2 -CS,Audience Seating Area,Gymnasium,0.65,W/ft2,6,,REQ,REQ,,ADD2,ADD2 -CS,Audience Seating Area,Motion Picture Theater,1.14,W/ft2,4,,REQ,REQ,,ADD2,ADD2 -CS,Banking Activity Area,General,0.86,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Breakroom,General,0.62,W/ft2,4,REQ,REQ,REQ,,, -CS,Computer Room,General,1.33,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Conference/meeting/multipurpose Room,General,1.07,W/ft2,6,REQ,REQ,,REQ,, -CS,Confinement Cells,General,0.81,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Copy/Print Room,General,0.56,W/ft2,6,REQ,REQ,,REQ,, -CS,Courtroom,General,1.39,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Electrical/mechanical Room,General,0.43,W/ft2,6,REQ,REQ,,,, -CS,Emergency Vehicle Garage,General,0.41,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Food Preparation Area,General,1.06,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Guest Room,General,0.77,W/ft2,6,,,,,,See section 9.4.1.3(b) -CS,Laundry/washing Area,General,0.43,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,"Loading Dock, Interior",General,0.58,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Locker Room,General,0.48,W/ft2,6,REQ,REQ,,REQ,, -CS,"Parking Area, Interior",General,0.14,W/ft2,4,,,,,,See Section 9.4.1.2 -CS,Pharmacy Area,General,1.34,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Sales Area,General,1.22,W/ft2,3,,REQ,,ADD2,ADD2, -CS,Stairway,General,0.58,W/ft2,10,REQ,REQ,REQ,ADD2,ADD2, -CS,Stairwell,General,0.58,W/ft2,10,REQ,REQ,REQ,ADD2,ADD2, -CS,Vehicular Maintenance Area,General,0.56,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Workshop,General,1.14,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Audience Seating Area,Penitentiary,0.28,W/ft2,4,,REQ,REQ,,ADD2,ADD2 -CS,Lounge/Breakroom,Healthcare Facility,0.78,W/ft2,6,REQ,REQ,,REQ,, -CS,Corridor,Hospital,0.92,W/ft2,,REQ,REQ,ADD2,ADD2,ADD2, -CS,Lobby,Hotel,1.06,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Audience Seating Area,Performing Arts Theater,2.03,W/ft2,8,,REQ,REQ,,ADD2,ADD2 -CS,Laboratory,In Or As A Classroom,1.2,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, -CS,Corridor,Manufacturing Facility,0.29,W/ft2,,REQ,REQ,,ADD2,ADD2, -CS,Audience Seating Area,Religious Facility,1.53,W/ft2,4,,REQ,REQ,,ADD2,ADD2 -CS,Lobby,Motion Picture Theater,0.45,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Office,Open Plan,0.81,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Classroom/lecture Hall/training Room,Penitentiary,1.34,W/ft2,4,REQ,REQ,,REQ,, -CS,Dining Area,Penitentiary,0.96,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Lobby,Performing Arts Theater,1.7,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, -CS,Audience Seating Area,Sports Arena,0.43,W/ft2,4,,REQ,REQ,,ADD2,ADD2 -SS,Transportation Facility,Airport Concourse,0.31,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Transportation Facility,Baggage/carousel Area,0.46,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Facility For The Visually Impaired,Chapel (used Primarily By Residents),1.06,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Sports Arena-playing Area,Class I Facility,2.47,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Sports Arena-playing Area,Class II Facility,1.96,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Sports Arena-playing Area,Class Iii Facility,1.7,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Sports Arena-playing Area,Class Iv Facility,1.13,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Manufacturing Facility,Detailed Manufacturing Area,0.93,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Retail Facilities,Dressing/Fitting Room,0.5,W/ft2,8,,REQ,,REQ,, -SS,Manufacturing Facility,Equipment Room,0.65,W/ft2,6,REQ,REQ,,ADD2,ADD2, -SS,Healthcare Facility,Exam/treatment Room,1.68,W/ft2,8,REQ,REQ,,ADD2,ADD2, -SS,Gymnasium/fitness Center,Exercise Area,0.5,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Manufacturing Facility,Extra High Bay Area (>50 Ft Floor-to-ceiling Height),1.05,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Religious Facility,Fellowship Hall,0.55,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Automotive,General,0.56,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Convention Center-exhibit Space,General,0.88,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Dormitory-living Quarters,General,0.54,W/ft2,8,,,,,, -SS,Fire Station-sleeping Quarters,General,0.2,W/ft2,6,,,,,, -SS,Performing Arts Theater-dressing Room,General,0.36,W/ft2,6,REQ,REQ,,REQ,, -SS,Post Office-sorting Area,General,0.68,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, -SS,Museum,General Exhibition Area,1.05,W/ft2,6,REQ,REQ,,ADD2,ADD2, -SS,Manufacturing Facility,High Bay Area (25 To 50 Ft Floor-to-ceiling Height),0.75,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Healthcare Facility,Imaging Room,1.06,W/ft2,6,,,,ADD2,ADD2, -SS,Manufacturing Facility,Low Bay Area (<25 Ft Floor-to-ceiling Height),0.96,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Retail Facilities,Mall Concourse,0.9,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Healthcare Facility,Medical Supply Room,0.54,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, -SS,Warehouse-storage Area,"Medium To Bulky, Palletized Items",0.35,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, -SS,Healthcare Facility,Nurse’s Station,0.81,W/ft2,6,REQ,REQ,,ADD2,ADD2, -SS,Healthcare Facility,Nursery,1,W/ft2,6,REQ,REQ,,ADD2,ADD2, -SS,Healthcare Facility,Operating Room,2.17,W/ft2,6,,,,ADD2,ADD2, -SS,Healthcare Facility,Patient Room,0.62,W/ft2,6,REQ,REQ,,ADD2,ADD2, -SS,Healthcare Facility,Physical Therapy Room,0.84,W/ft2,6,REQ,REQ,,ADD2,ADD2, -SS,Gymnasium/fitness Center,Playing Area,0.82,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Library,Reading Area,0.82,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Healthcare Facility,Recovery Room,1.03,W/ft2,6,REQ,REQ,,ADD2,ADD2, -SS,Facility For The Visually Impaired,Recreation Room/common Living Room (and Not Used Primarily By Staff),1.8,W/ft2,6,REQ,REQ,,ADD2,ADD2, -SS,Museum,Restoration Room,0.85,W/ft2,6,REQ,REQ,,ADD2,ADD2, -SS,Retail,Sales Additional (type 1),0.45,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Retail,Sales Additional (type 2),0.45,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Retail,Sales Additional (type 3),1.05,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Retail,Sales Additional (type 4),1.88,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Warehouse-storage Area,"Smaller, Hand-carried Items",0.69,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, -SS,Library,Stacks,1.2,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, -SS,Transportation Facility,Terminal Ticket Counter,0.62,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Religious Facility,Worship/Pulpit/Choir Area,1.53,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,None,None,0,W/ft2,,,,,,, diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2019.csv b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2019.csv deleted file mode 100644 index 951dc59e50..0000000000 --- a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2019.csv +++ /dev/null @@ -1,140 +0,0 @@ -method,lighting_primary_space_type,lighting_secondary_space_type,lighting_power_density,unit,rcr_threshold,automatic_daylight_responsive_controls_for_sidelighting,automatic_daylight_responsive_controls_for_toplighting,automatic_partial_off,automatic_full_off,scheduled_shutoff,annotation -BA,Automotive facility,General,0.75,W/ft2,,,,,,, -BA,Convention center,General,0.64,W/ft2,,,,,,, -BA,Courthouse,General,0.79,W/ft2,,,,,,, -BA,Dining: Bar lounge/leisure,General,0.8,W/ft2,,,,,,, -BA,Dining: Cafeteria/fast food,General,0.76,W/ft2,,,,,,, -BA,Dining: Family,General,0.71,W/ft2,,,,,,, -BA,Dormitory,General,0.53,W/ft2,,,,,,, -BA,Exercise center,General,0.72,W/ft2,,,,,,, -BA,Fire station,General,0.56,W/ft2,,,,,,, -BA,Gymnasium,General,0.76,W/ft2,,,,,,, -BA,Health-care clinic,General,0.81,W/ft2,,,,,,, -BA,Hospital,General,0.96,W/ft2,,,,,,, -BA,Hotel/motel,General,0.56,W/ft2,,,,,,, -BA,Library,General,0.83,W/ft2,,,,,,, -BA,Manufacturing facility,General,0.82,W/ft2,,,,,,, -BA,Motion picture theater,General,0.44,W/ft2,,,,,,, -BA,Multifamily,General,0.45,W/ft2,,,,,,, -BA,Museum,General,0.55,W/ft2,,,,,,, -BA,Office,General,0.64,W/ft2,,,,,,, -BA,Parking garage,General,0.18,W/ft2,,,,,,, -BA,Penitentiary,General,0.69,W/ft2,,,,,,, -BA,Performing arts theater,General,0.84,W/ft2,,,,,,, -BA,Police station,General,0.66,W/ft2,,,,,,, -BA,Post office,General,0.65,W/ft2,,,,,,, -BA,Religious facility,General,0.67,W/ft2,,,,,,, -BA,Retail,General,0.84,W/ft2,,,,,,, -BA,School/university,General,0.72,W/ft2,,,,,,, -BA,Sports arena,General,0.76,W/ft2,,,,,,, -BA,Town hall,General,0.69,W/ft2,,,,,,, -BA,Transportation,General,0.5,W/ft2,,,,,,, -BA,Warehouse,General,0.45,W/ft2,,,,,,, -BA,Workshop,General,0.91,W/ft2,,,,,,, -CS,Atrium,< 20 ft in height,0.39,W/ft2,,REQ,REQ,,ADD2,ADD2, -CS,Atrium,>= 20 ft and <= 40 ft in height,0.48,W/ft2,,REQ,REQ,,ADD2,ADD2, -CS,Atrium,> 40 ft in height,0.6,W/ft2,11,REQ,REQ,,ADD2,ADD2, -CS,Audience Seating Area,Auditorium,0.61,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Audience Seating Area,Gymnasium,0.23,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Audience Seating Area,Motion picture theater,0.27,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Audience Seating Area,Penitentiary,0.67,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Audience Seating Area,Performing arts theater,1.16,W/ft2,8,REQ,REQ,,ADD2,ADD2, -CS,Audience Seating Area,Religious facility,0.72,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Audience Seating Area,Sports arena,0.33,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Audience Seating Area,All other audience seating areas,0.23,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Banking Activity Area,General,0.61,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Breakroom,General,0.59,W/ft2,4,REQ,REQ,,REQ,, -CS,Classroom/Lecture Hall/Training Room,Penitentiary,0.89,W/ft2,4,REQ,REQ,,REQ,, -CS,Classroom/Lecture Hall/Training Room,All other classrooms/lecture halls/training rooms,0.71,W/ft2,4,REQ,REQ,,REQ,, -CS,Conference/Meeting/Multipurpose Room,General,0.97,W/ft2,6,REQ,REQ,,REQ,, -CS,Confinement Cells,General,0.7,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Copy/Print Room,General,0.31,W/ft2,6,REQ,REQ,,REQ,, -CS,Corridor,Facility for the visually impaired (and not used primarily by the staff),0.71,W/ft2,,REQ,REQ,REQ,ADD2,ADD2,rcr_threshold: width<8 ft -CS,Corridor,Hospital,0.71,W/ft2,,REQ,REQ,ADD2,ADD2,ADD2,rcr_threshold: width<8 ft -CS,Corridor,All other corridors,0.41,W/ft2,,REQ,REQ,REQ,ADD2,ADD2,rcr_threshold: width<8 ft -CS,Courtroom,General,1.2,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Computer Room,General,0.94,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Dining Area,Penitentiary,0.42,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Dining Area,Facility for the visually impaired (and not used primarily by staff),1.27,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Dining Area,Bar/lounge or leisure dining,0.86,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Dining Area,Cafeteria or fast food dining,0.4,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Dining Area,Family dining,0.6,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Dining Area,All other dining areas,0.43,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Electrical/Mechanical Room,General,0.43,W/ft2,6,REQ,REQ,,,, -CS,Emergency Vehicle Garage,General,0.52,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Food Preparation Area,General,1.09,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Guest Room,General,0.41,W/ft2,6,,,,,,See section 9.4.1.3(b) -CS,Laboratory,In or as a classroom,1.11,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, -CS,Laboratory,All other laboratories,1.33,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Laundry/Washing Area,General,0.53,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,"Loading Dock, Interior",General,0.88,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Lobby,Facility for the visually impaired (and not used primarily by the staff),1.69,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, -CS,Lobby,Elevator,0.65,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Lobby,Hotel,0.51,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Lobby,Motion picture theater,0.23,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Lobby,Performing arts theater ,1.25,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, -CS,Lobby,All other lobbies,0.84,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, -CS,Locker Room,General,0.52,W/ft2,6,REQ,REQ,,REQ,, -CS,Lounge/Breakroom,Healthcare facility,0.42,W/ft2,6,REQ,REQ,,REQ,, -CS,Lounge/Breakroom,All other lounges/breakrooms,0.59,W/ft2,4,REQ,REQ,,REQ,, -CS,Office,Enclosed and <= 250 ft2,0.74,W/ft2,8,REQ,REQ,,REQ,, -CS,Office,Enclosed and > 250 ft2,0.66,W/ft2,8,REQ,REQ,,ADD2,ADD2, -CS,Office,Open plan,0.61,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,"Parking Area, Interior",General,0.15,W/ft2,4,,,,,,See Section 9.4.1.2 -CS,Pharmacy Area,General,1.66,W/ft2,6,REQ,REQ,,ADD2,ADD2, -CS,Restroom,Facility for the visually impaired (and not used primarily by the staff),1.26,W/ft2,8,REQ,REQ,,REQ,, -CS,Restroom,All other restrooms,0.63,W/ft2,8,REQ,REQ,,REQ,, -CS,Sales Area,General,1.05,W/ft2,6,,REQ,,ADD2,ADD2, -CS,"Seating Area, General",General,0.23,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Stairway,General,0.49,W/ft2,10,REQ,REQ,REQ,ADD2,ADD2, -CS,Stairwell,General,0.49,W/ft2,10,REQ,REQ,REQ,ADD2,ADD2, -CS,Storage Room,< 50 ft2,0.51,W/ft2,9,,,,ADD2,ADD2, -CS,Storage Room,>= 50 ft2,0.38,W/ft2,6,REQ,REQ,,REQ,, -CS,Vehicular Maintenance Area,General,0.6,W/ft2,4,REQ,REQ,,ADD2,ADD2, -CS,Workshop,General,1.26,W/ft2,6,REQ,REQ,,ADD2,ADD2, -SS,Facility for the Visually Impaired,Chapel (used primarily by residents),0.7,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Facility for the Visually Impaired,Recreation room/common living room (and not used primarily by staff),1.77,W/ft2,6,REQ,REQ,,ADD2,ADD2, -SS,Automotive,General,0.6,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Convention Center: Exhibit Space,General,0.61,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Dormitory: Living Quarters,General,0.5,W/ft2,8,,,,,, -SS,Fire Station: Sleeping Quarters,General,0.23,W/ft2,6,,,,,, -SS,Gymnasium/Fitness Center,Exercise area,0.9,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Gymnasium/Fitness Center,Playing area,0.85,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Healthcare Facility,Exam/treatment room,1.4,W/ft2,8,REQ,REQ,,ADD2,ADD2, -SS,Healthcare Facility,Imaging room,0.94,W/ft2,6,,,,ADD2,ADD2, -SS,Healthcare Facility,Medical supply room,0.62,W/ft2,6,REQ,REQ,,REQ,, -SS,Healthcare Facility,Nursery,0.92,W/ft2,6,REQ,REQ,,ADD2,ADD2, -SS,Healthcare Facility,Nurse's station,1.17,W/ft2,6,REQ,REQ,,ADD2,ADD2, -SS,Healthcare Facility,Operating room,2.26,W/ft2,6,,,,ADD2,ADD2, -SS,Healthcare Facility,Patient room,0.68,W/ft2,6,REQ,REQ,,ADD2,ADD2, -SS,Healthcare Facility,Physical therapy room,0.91,W/ft2,6,REQ,REQ,,ADD2,ADD2, -SS,Healthcare Facility,Recovery room,1.25,W/ft2,6,REQ,REQ,,ADD2,ADD2, -SS,Library,Reading area,0.96,W/ft2,6,REQ,REQ,,ADD2,ADD2, -SS,Library,Stacks,1.18,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, -SS,Manufacturing Facility,Detailed manufacturing area,0.8,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Manufacturing Facility,Equipment room,0.76,W/ft2,6,REQ,REQ,,ADD2,ADD2, -SS,Manufacturing Facility,Extra high bay area (> 50 ft floor-to-ceiling height),1.42,W/ft2,8,REQ,REQ,,ADD2,ADD2, -SS,Manufacturing Facility,High bay area (25 to 50 ft floor-to-ceiling height),1.24,W/ft2,6,REQ,REQ,,ADD2,ADD2, -SS,Manufacturing Facility,Low bay area (< 25 ft floor-to-ceiling height),0.86,W/ft2,3,REQ,REQ,,ADD2,ADD2, -SS,Museum,General exhibition area,0.31,W/ft2,6,REQ,REQ,,ADD2,ADD2, -SS,Museum,Restoration room,1.1,W/ft2,6,REQ,REQ,,ADD2,ADD2, -SS,Performing Arts Theater: Dressing Room,General,0.41,W/ft2,6,REQ,REQ,,REQ,, -SS,Post Office: Sorting Area,General,0.76,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, -SS,Religious Facility,Fellowship hall,0.54,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Religious Facility,Worship/pulpit/choir area,0.85,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Retail Facilities,Dressing/fitting room,0.51,W/ft2,8,,REQ,,REQ,, -SS,Retail Facilities,Mall concourse,0.82,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Sports Arena: Playing Area,Class I facility,2.94,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Sports Arena: Playing Area,Class II facility,2.01,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Sports Arena: Playing Area,Class III facility,1.3,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Sports Arena: Playing Area,Class IV facility,0.86,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Transportation Facility,Baggage/carousel area,0.39,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Transportation Facility,Airport concourse,0.25,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Transportation Facility,Ticket counter,0.51,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Warehouse: Storage Area,"Medium to bulky, palletized items",0.33,W/ft2,4,REQ,REQ,REQ,ADD2,ADD2, -SS,Warehouse: Storage Area,"Smaller, hand-carried items",0.69,W/ft2,6,REQ,REQ,REQ,ADD2,ADD2, -SS,Retail,Sales Additional (Retail Area 1),0.45,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Retail,Sales Additional (Retail Area 2),0.45,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Retail,Sales Additional (Retail Area 3),1.05,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,Retail,Sales Additional (Retail Area 4),1.88,W/ft2,4,REQ,REQ,,ADD2,ADD2, -SS,None,None,0,W/ft2,,,,,,, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_1999.csv b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_1999.csv deleted file mode 100644 index dc81d12379..0000000000 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_1999.csv +++ /dev/null @@ -1,84 +0,0 @@ -ventilation_primary_space_type,ventilation_secondary_space_type,ventilation_rate_occupant,ventilation_rate_occupant_unit,ventilation_rate_area,ventilation_rate_area_unit,occupancy_per_area,occupancy_per_area_unit,air_class,os,annotation -"Dry Cleaners, Laundries",Commercial laundry,25,cfm/person,0,cfm/ft2,10,ppl/1000 ft2,,, -"Dry Cleaners, Laundries",Commercial dry cleaner,30,cfm/person,0,cfm/ft2,30,ppl/1000 ft2,,, -"Dry Cleaners, Laundries","Storage, pick up",35,cfm/person,0,cfm/ft2,30,ppl/1000 ft2,,, -"Dry Cleaners, Laundries",Coin-operated laundries,15,cfm/person,0,cfm/ft2,20,ppl/1000 ft2,,, -"Dry Cleaners, Laundries",Coin-operated dry cleaner,15,cfm/person,0,cfm/ft2,20,ppl/1000 ft2,,, -Foor and Beverage Service,Dining rooms,20,cfm/person,0,cfm/ft2,70,ppl/1000 ft2,,, -Foor and Beverage Service,"Cafeteria, fast food",20,cfm/person,0,cfm/ft2,100,ppl/1000 ft2,,, -Foor and Beverage Service,"Bars, cocktails lounges",30,cfm/person,0,cfm/ft2,100,ppl/1000 ft2,,, -Foor and Beverage Service,Kitchen (cooking),15,cfm/person,0,cfm/ft2,20,ppl/1000 ft2,,, -"Garages, Repair, Service Stations",Enclosed parking garage,0,cfm/person,1.5,cfm/ft2,0,ppl/1000 ft2,,, -"Garages, Repair, Service Stations",Auto repair rooms,0,cfm/person,1.5,cfm/ft2,0,ppl/1000 ft2,,, -"Hotels, Motels, Resorts, Dormitories",Bedrooms,0,cfm/person,30,cfm/room,0,ppl/1000 ft2,,, -"Hotels, Motels, Resorts, Dormitories",Living rooms,0,cfm/person,30,cfm/room,0,ppl/1000 ft2,,, -"Hotels, Motels, Resorts, Dormitories",Baths,0,cfm/person,35,cfm/room,0,ppl/1000 ft2,,, -"Hotels, Motels, Resorts, Dormitories",Lobbies,15,cfm/person,0,cfm/ft2,30,ppl/1000 ft2,,, -"Hotels, Motels, Resorts, Dormitories",Conference rooms,20,cfm/person,0,cfm/ft2,50,ppl/1000 ft2,,, -"Hotels, Motels, Resorts, Dormitories",Assembly rooms,15,cfm/person,0,cfm/ft2,120,ppl/1000 ft2,,, -"Hotels, Motels, Resorts, Dormitories",Dormitory sleeping areas,15,cfm/person,0,cfm/ft2,20,ppl/1000 ft2,,, -"Hotels, Motels, Resorts, Dormitories",Gambling casinos,30,cfm/person,0,cfm/ft2,120,ppl/1000 ft2,,, -Offices,Office space,20,cfm/person,0,cfm/ft2,7,ppl/1000 ft2,,, -Offices,Reception areas,15,cfm/person,0,cfm/ft2,60,ppl/1000 ft2,,, -Offices,Telecommunitcation centers and data entry areas,20,cfm/person,0,cfm/ft2,60,ppl/1000 ft2,,, -Offices,Conference rooms,20,cfm/person,0,cfm/ft2,50,ppl/1000 ft2,,, -Public Spaces,Corridors and utilities,0,cfm/person,0.05,cfm/ft2,0,ppl/1000 ft2,,, -Public Spaces,"Public restrooms, cfm/wc or cfm/urinal",50,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,,, -Public Spaces,Locker and dressing rooms,0,cfm/person,0.5,cfm/ft2,0,ppl/1000 ft2,,, -Public Spaces,Smoking lounge,60,cfm/person,0,cfm/ft2,70,ppl/1000 ft2,,, -Public Spaces,Elevators,0,cfm/person,1,cfm/ft2,0,ppl/1000 ft2,,, -"Retail Stores, Sales Floors, and Show Room Floors",Basement and street,0,cfm/person,0.3,cfm/ft2,30,ppl/1000 ft2,,, -"Retail Stores, Sales Floors, and Show Room Floors",Upper floors,0,cfm/person,0.2,cfm/ft2,20,ppl/1000 ft2,,, -"Retail Stores, Sales Floors, and Show Room Floors",Storage rooms,0,cfm/person,0.15,cfm/ft2,15,ppl/1000 ft2,,, -"Retail Stores, Sales Floors, and Show Room Floors",Dressing rooms,0,cfm/person,0.2,cfm/ft2,0,ppl/1000 ft2,,, -"Retail Stores, Sales Floors, and Show Room Floors",Malls and arcades,0,cfm/person,0.2,cfm/ft2,20,ppl/1000 ft2,,, -"Retail Stores, Sales Floors, and Show Room Floors",Shipping and receiving,0,cfm/person,0.15,cfm/ft2,10,ppl/1000 ft2,,, -"Retail Stores, Sales Floors, and Show Room Floors",Warehouses,0,cfm/person,0.05,cfm/ft2,5,ppl/1000 ft2,,, -"Retail Stores, Sales Floors, and Show Room Floors",Smoking lounge,60,cfm/person,0,cfm/ft2,70,ppl/1000 ft2,,, -Specialty Shops,Barber,15,cfm/person,0,cfm/ft2,25,ppl/1000 ft2,,, -Specialty Shops,Beauty,25,cfm/person,0,cfm/ft2,25,ppl/1000 ft2,,, -Specialty Shops,Reducing salons,15,cfm/person,0,cfm/ft2,20,ppl/1000 ft2,,, -Specialty Shops,Florists,15,cfm/person,0,cfm/ft2,8,ppl/1000 ft2,,, -Specialty Shops,"Clothiers, furniture",0,cfm/person,0.3,cfm/ft2,0,ppl/1000 ft2,,, -Specialty Shops,"Hardwar, drugs, fabric",15,cfm/person,0,cfm/ft2,8,ppl/1000 ft2,,, -Specialty Shops,Supermarkets,15,cfm/person,0,cfm/ft2,8,ppl/1000 ft2,,, -Specialty Shops,Pet shops,0,cfm/person,1,cfm/ft2,0,ppl/1000 ft2,,, -Sports and Amusement,Spectator areas,15,cfm/person,0,cfm/ft2,150,ppl/1000 ft2,,, -Sports and Amusement,Game rooms,25,cfm/person,0,cfm/ft2,70,ppl/1000 ft2,,, -Sports and Amusement,Ice arenas (playing areas),0,cfm/person,0.5,cfm/ft2,0,ppl/1000 ft2,,, -Sports and Amusement,Swimming pools (pool and deck area),0,cfm/person,0.5,cfm/ft2,0,ppl/1000 ft2,,, -Sports and Amusement,Playing floors (gymnasium),20,cfm/person,0,cfm/ft2,30,ppl/1000 ft2,,, -Sports and Amusement,Ballrooms and discos,25,cfm/person,0,cfm/ft2,100,ppl/1000 ft2,,, -Sports and Amusement,Bowling alleys (seating areas),25,cfm/person,0,cfm/ft2,70,ppl/1000 ft2,,, -Theaters,Ticket booths,20,cfm/person,0,cfm/ft2,60,ppl/1000 ft2,,, -Theaters,Lobbies,20,cfm/person,0,cfm/ft2,15,ppl/1000 ft2,,, -Theaters,Auditorium,15,cfm/person,0,cfm/ft2,150,ppl/1000 ft2,,, -Theaters,"Stages, studios",15,cfm/person,0,cfm/ft2,70,ppl/1000 ft2,,, -Transportation,Waiting rooms,15,cfm/person,0,cfm/ft2,100,ppl/1000 ft2,,, -Transportation,Platforms,15,cfm/person,0,cfm/ft2,100,ppl/1000 ft2,,, -Transportation,Vehicles,15,cfm/person,0,cfm/ft2,150,ppl/1000 ft2,,, -Workrooms,Meat processing,10,cfm/person,0,cfm/ft2,10,ppl/1000 ft2,,, -Workrooms,Photo studios,15,cfm/person,0,cfm/ft2,10,ppl/1000 ft2,,, -Workrooms,Darkrooms,0,cfm/person,0.5,cfm/ft2,10,ppl/1000 ft2,,, -Workrooms,Pharmacy,15,cfm/person,0,cfm/ft2,20,ppl/1000 ft2,,, -Workrooms,Bank vaults,15,cfm/person,0,cfm/ft2,5,ppl/1000 ft2,,, -Workrooms,"Duplicating, printing",0,cfm/person,0.5,cfm/ft2,0,ppl/1000 ft2,,, -Education,Classroom,15,cfm/person,0,cfm/ft2,50,ppl/1000 ft2,,, -Education,Laboratories,20,cfm/person,0,cfm/ft2,30,ppl/1000 ft2,,, -Education,Training shop,20,cfm/person,0,cfm/ft2,30,ppl/1000 ft2,,, -Education,Music rooms,15,cfm/person,0,cfm/ft2,50,ppl/1000 ft2,,, -Education,Libraries,15,cfm/person,0,cfm/ft2,20,ppl/1000 ft2,,, -Education,Locker rooms,0,cfm/person,0.5,cfm/ft2,0,ppl/1000 ft2,,, -Education,Corridors,0,cfm/person,0.1,cfm/ft2,0,ppl/1000 ft2,,, -Education,Auditoriums,15,cfm/person,0,cfm/ft2,150,ppl/1000 ft2,,, -Education,Smoking lounge,60,cfm/person,0,cfm/ft2,710,ppl/1000 ft2,,, -"Hospitals, Nursing and Convalescent Homes",Patient rooms,25,cfm/person,0,cfm/ft2,10,ppl/1000 ft2,,, -"Hospitals, Nursing and Convalescent Homes",Medical procedure,15,cfm/person,0,cfm/ft2,20,ppl/1000 ft2,,, -"Hospitals, Nursing and Convalescent Homes",Operating rooms,30,cfm/person,0,cfm/ft2,20,ppl/1000 ft2,,, -"Hospitals, Nursing and Convalescent Homes",Recovery and ICU,15,cfm/person,0,cfm/ft2,20,ppl/1000 ft2,,, -"Hospitals, Nursing and Convalescent Homes",Autopsy rooms,0,cfm/person,0.5,cfm/ft2,0,ppl/1000 ft2,,, -"Hospitals, Nursing and Convalescent Homes",Physical therapy,15,cfm/person,0,cfm/ft2,20,ppl/1000 ft2,,, -Correctional Facilties,Cells,20,cfm/person,0,cfm/ft2,20,ppl/1000 ft2,,, -Correctional Facilties,Dining halls,15,cfm/person,0,cfm/ft2,100,ppl/1000 ft2,,, -Correctional Facilties,Guard stations,15,cfm/person,0,cfm/ft2,40,ppl/1000 ft2,,, -None,None,0,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,,, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2004.csv b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2004.csv deleted file mode 100644 index b79b879712..0000000000 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2004.csv +++ /dev/null @@ -1,65 +0,0 @@ -ventilation_primary_space_type,ventilation_secondary_space_type,ventilation_rate_occupant,ventilation_rate_occupant_unit,ventilation_rate_area,ventilation_rate_area_unit,occupancy_per_area,occupancy_per_area_unit,air_class,os,annotation -Correctional Facilities,Cell,5,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, -Correctional Facilities,Day room,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, -Correctional Facilities,Guard stations,5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,, -Correctional Facilities,Booking/waiting,7.5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,2,, -Educational Facilities,Daycare (through age 4),10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, -Educational Facilities,Classrooms (ages 5-8),10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, -Educational Facilities,Classrooms (age 9 plus),10,cfm/person,0.12,cfm/ft2,35,ppl/1000 ft2,1,, -Educational Facilities,Lecture classroom,7.5,cfm/person,0.06,cfm/ft2,65,ppl/1000 ft2,1,, -Educational Facilities,Lecture hall (fixed seats),7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -Educational Facilities,Art classroom,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, -Educational Facilities,Science laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,,, -Educational Facilities,Wood/metal shop,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, -Educational Facilities,Computer lab,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, -Educational Facilities,Media center,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, -Educational Facilities,Music/theater/dance,10,cfm/person,0.06,cfm/ft2,35,ppl/1000 ft2,1,, -Educational Facilities,Multi-use assembly,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, -Food and Beverage Service,Restaurant dining rooms,7.5,cfm/person,0.18,cfm/ft2,70,ppl/1000 ft2,2,, -Food and Beverage Service,Cafeteria/fast food dining,7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, -Food and Beverage Service,"Bars, cocktail lounges",7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, -General,Conference/meeting,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, -General,Corridors,,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,1,, -General,Storage rooms,,cfm/person,0.12,cfm/ft2,,ppl/1000 ft2,1,, -"Hotels, Motels, Resorts, Dormitories",Bedroom/living Room,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,, -"Hotels, Motels, Resorts, Dormitories",Barracks sleeping areas,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, -"Hotels, Motels, Resorts, Dormitories",Lobbies/prefunction,7.5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, -"Hotels, Motels, Resorts, Dormitories",Multi-purpose assembly,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,, -Office Buildings,Office space,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1,, -Office Buildings,Reception areas,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, -Office Buildings,Telephone/data entry,5,cfm/person,0.06,cfm/ft2,60,ppl/1000 ft2,1,, -Office Buildings,Main entry lobbies,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,, -Miscellaneous Spaces,Bank vaults/safe deposit,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,2,, -Miscellaneous Spaces,Computer (not printing),5,cfm/person,0.06,cfm/ft2,4,ppl/1000 ft2,1,, -Miscellaneous Spaces,Pharmacy (prep. area),5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, -Miscellaneous Spaces,Photo studios,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, -Miscellaneous Spaces,Shipping/receiving,,cfm/person,0.12,cfm/ft2,,ppl/1000 ft2,1,, -Miscellaneous Spaces,Transportation waiting,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, -Miscellaneous Spaces,Warehouses,,cfm/person,0.06,cfm/ft2,,ppl/1000 ft2,2,, -Public Assembly Spaces,Auditorium seating area,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -Public Assembly Spaces,Places of religious workshop,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,, -Public Assembly Spaces,Courtrooms,5,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, -Public Assembly Spaces,Legislative chambers,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, -Public Assembly Spaces,Libraries,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, -Public Assembly Spaces,Lobbies,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -Public Assembly Spaces,Museums (children's),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, -Public Assembly Spaces,Museums/galleries,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, -Retail,Sales (except as below),7.5,cfm/person,0.12,cfm/ft2,15,ppl/1000 ft2,2,, -Retail,Mall common areas,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, -Retail,Barber shop,7.5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,2,, -Retail,Beauty and nail salons,20,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, -Retail,Pet shops (animal areas),7.5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, -Retail,Supermarket,7.5,cfm/person,0.06,cfm/ft2,8,ppl/1000 ft2,1,, -Retail,Coin-operated laundries,7.5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,2,, -Sports and Entertainment,Sports arena (play area),,cfm/person,0.3,cfm/ft2,,ppl/1000 ft2,1,, -Sports and Entertainment,"Gym, stadium (play area)",,cfm/person,0.3,cfm/ft2,30,ppl/1000 ft2,2,, -Sports and Entertainment,Spectator areas,7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -Sports and Entertainment,Swimming (pool & deck),,cfm/person,0.48,cfm/ft2,,ppl/1000 ft2,2,, -Sports and Entertainment,Disco/dance floors,20,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, -Sports and Entertainment,Health club/aerobics room,20,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,2,, -Sports and Entertainment,Health club/weight rooms,20,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,2,, -Sports and Entertainment,Bowling alley (seating),10,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, -Sports and Entertainment,Gambling casinos,7.5,cfm/person,0.18,cfm/ft2,120,ppl/1000 ft2,1,, -Sports and Entertainment,Game arcades,7.5,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, -Sports and Entertainment,"Stages, studios",10,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, -None,None,0,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,,, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2007.csv b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2007.csv deleted file mode 100644 index 82e93a4e95..0000000000 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2007.csv +++ /dev/null @@ -1,76 +0,0 @@ -ventilation_primary_space_type,ventilation_secondary_space_type,ventilation_rate_occupant,ventilation_rate_occupant_unit,ventilation_rate_area,ventilation_rate_area_unit,occupancy_per_area,occupancy_per_area_unit,air_class,os,annotation -Correctional Facilities,Cell,5,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, -Correctional Facilities,Day room,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, -Correctional Facilities,Guard stations,5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,, -Correctional Facilities,Booking/waiting,7.5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,2,, -Educational Facilities,Daycare (through age 4),10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, -Educational Facilities,Daycare sickroom,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,3,, -Educational Facilities,Classrooms (ages 5-8),10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, -Educational Facilities,Classrooms (age 9 plus),10,cfm/person,0.12,cfm/ft2,35,ppl/1000 ft2,1,, -Educational Facilities,Lecture classroom,7.5,cfm/person,0.06,cfm/ft2,65,ppl/1000 ft2,1,, -Educational Facilities,Lecture hall (fixed seats),7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -Educational Facilities,Art classroom,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, -Educational Facilities,Science laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, -Educational Facilities,University/college laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, -Educational Facilities,Wood/metal shop,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, -Educational Facilities,Computer lab,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, -Educational Facilities,Media center,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, -Educational Facilities,Music/theater/dance,10,cfm/person,0.06,cfm/ft2,35,ppl/1000 ft2,1,, -Educational Facilities,Multi-use assembly,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, -Food and Beverage Service,Restaurant dining rooms,7.5,cfm/person,0.18,cfm/ft2,70,ppl/1000 ft2,2,, -Food and Beverage Service,Cafeteria/fast food dining,7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, -Food and Beverage Service,"Bars, cocktail lounges",7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, -General,Break rooms,5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,1,, -General,Coffee stations,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, -General,Conference/meeting,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, -General,Corridors,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, -General,Storage rooms,0,cfm/person,0.12,cfm/ft2,0,ppl/1000 ft2,1,, -"Hotels, Motels, Resorts, Dormitories",Bedroom/living Room,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,, -"Hotels, Motels, Resorts, Dormitories",Barracks sleeping areas,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, -"Hotels, Motels, Resorts, Dormitories","Laundry rooms, central",5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,2,, -"Hotels, Motels, Resorts, Dormitories",Laundry rooms within dwelling units,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, -"Hotels, Motels, Resorts, Dormitories",Lobbies/prefunction,7.5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, -"Hotels, Motels, Resorts, Dormitories",Multipurpose assembly,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,, -Office Buildings,Office space,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1,, -Office Buildings,Reception areas,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, -Office Buildings,Telephone/data entry,5,cfm/person,0.06,cfm/ft2,60,ppl/1000 ft2,1,, -Office Buildings,Main entry lobbies,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,, -Miscellaneous Spaces,Bank vaults/safe deposit,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,2,, -Miscellaneous Spaces,Computer (not printing),5,cfm/person,0.06,cfm/ft2,4,ppl/1000 ft2,1,, -Miscellaneous Spaces,Electrical equipment rooms,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, -Miscellaneous Spaces,Elevator machine rooms,0,cfm/person,0.12,cfm/ft2,0,ppl/1000 ft2,1,, -Miscellaneous Spaces,Pharmacy (prep. area),5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, -Miscellaneous Spaces,Photo studios,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, -Miscellaneous Spaces,Shipping/receiving,0,cfm/person,0.12,cfm/ft2,0,ppl/1000 ft2,1,, -Miscellaneous Spaces,Telephone closets,0,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,1,, -Miscellaneous Spaces,Transportation waiting,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, -Miscellaneous Spaces,Warehouses,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,2,, -Public Assembly Spaces,Auditorium seating area,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -Public Assembly Spaces,Places of religious workshop,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,, -Public Assembly Spaces,Courtrooms,5,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, -Public Assembly Spaces,Legislative chambers,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, -Public Assembly Spaces,Libraries,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, -Public Assembly Spaces,Lobbies,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -Public Assembly Spaces,Museums (children's),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, -Public Assembly Spaces,Museums/galleries,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, -Residential,Dwelling unit,5,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, -Residential,Common corridors,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, -Retail,Sales (except as below),7.5,cfm/person,0.12,cfm/ft2,15,ppl/1000 ft2,2,, -Retail,Mall common areas,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, -Retail,Barbershop,7.5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,2,, -Retail,Beauty and nail salons,20,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, -Retail,Pet shops (animal areas),7.5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, -Retail,Supermarket,7.5,cfm/person,0.06,cfm/ft2,8,ppl/1000 ft2,1,, -Retail,Coin-operated laundries,7.5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,2,, -Sports and Entertainment,Sports arena (play area),0,cfm/person,0.3,cfm/ft2,0,ppl/1000 ft2,1,, -Sports and Entertainment,"Gym, stadium (play area)",0,cfm/person,0.3,cfm/ft2,30,ppl/1000 ft2,2,, -Sports and Entertainment,Spectator areas,7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -Sports and Entertainment,Swimming (pool & deck),0,cfm/person,0.48,cfm/ft2,0,ppl/1000 ft2,2,, -Sports and Entertainment,Disco/dance floors,20,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, -Sports and Entertainment,Health club/aerobics room,20,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,2,, -Sports and Entertainment,Health club/weight rooms,20,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,2,, -Sports and Entertainment,Bowling alley (seating),10,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, -Sports and Entertainment,Gambling casinos,7.5,cfm/person,0.18,cfm/ft2,120,ppl/1000 ft2,1,, -Sports and Entertainment,Game arcades,7.5,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, -Sports and Entertainment,"Stages, studios",10,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, -None,None,0,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,,, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2010.csv b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2010.csv deleted file mode 100644 index 1bf2cf36cc..0000000000 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2010.csv +++ /dev/null @@ -1,80 +0,0 @@ -ventilation_primary_space_type,ventilation_secondary_space_type,ventilation_rate_occupant,ventilation_rate_occupant_unit,ventilation_rate_area,ventilation_rate_area_unit,occupancy_per_area,occupancy_per_area_unit,air_class,os,annotation -Correctional Facilities,Cell,5,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, -Correctional Facilities,Dayroom,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, -Correctional Facilities,Guard stations,5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,, -Correctional Facilities,Booking/waiting,7.5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,2,, -Educational Facilities,Daycare (through age 4),10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, -Educational Facilities,Daycare sickroom,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,3,, -Educational Facilities,Classrooms (ages 5-8),10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, -Educational Facilities,Classrooms (age 9 plus),10,cfm/person,0.12,cfm/ft2,35,ppl/1000 ft2,1,, -Educational Facilities,Lecture classroom,7.5,cfm/person,0.06,cfm/ft2,65,ppl/1000 ft2,1,, -Educational Facilities,Lecture hall (fixed seats),7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -Educational Facilities,Art classroom,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, -Educational Facilities,Science laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, -Educational Facilities,University/college laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, -Educational Facilities,Wood/metal shop,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, -Educational Facilities,Computer lab,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, -Educational Facilities,Media center,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, -Educational Facilities,Music/theater/dance,10,cfm/person,0.06,cfm/ft2,35,ppl/1000 ft2,1,, -Educational Facilities,Multi-use assembly,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, -Food and Beverage Service,Restaurant dining rooms,7.5,cfm/person,0.18,cfm/ft2,70,ppl/1000 ft2,2,, -Food and Beverage Service,Cafeteria/fast food dining,7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, -Food and Beverage Service,"Bars, cocktail lounges",7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, -Food and Beverage Service,Kitchen (cooking),7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2,, -General,Break rooms,5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,1,, -General,Coffee stations,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, -General,Conference/meeting,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, -General,Corridors,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, -General,Occupiable storage rooms for liquids or gels,5,cfm/person,0.12,cfm/ft2,2,ppl/1000 ft2,2,, -"Hotels, Motels, Resorts, Dormitories",Bedroom/living Room,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,, -"Hotels, Motels, Resorts, Dormitories",Barracks sleeping areas,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, -"Hotels, Motels, Resorts, Dormitories","Laundry rooms, central",5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,2,, -"Hotels, Motels, Resorts, Dormitories",Laundry rooms within dwelling units,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, -"Hotels, Motels, Resorts, Dormitories",Lobbies/prefunction,7.5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, -"Hotels, Motels, Resorts, Dormitories",Multipurpose assembly,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,, -Office Buildings,Breakrooms,5,cfm/person,0.12,cfm/ft2,50,ppl/1000 ft2,1,, -Office Buildings,Main entry lobbies,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,, -Office Buildings,Occupiable storage rooms for dry materials,5,cfm/person,0.06,cfm/ft2,2,ppl/1000 ft2,1,, -Office Buildings,Office space,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1,, -Office Buildings,Reception areas,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, -Office Buildings,Telephone/data entry,5,cfm/person,0.06,cfm/ft2,60,ppl/1000 ft2,1,, -Miscellaneous Spaces,Bank vaults/safe deposit,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,2,, -Miscellaneous Spaces,Banks or bank lobbies,7.5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,, -Miscellaneous Spaces,Computer (not printing),5,cfm/person,0.06,cfm/ft2,4,ppl/1000 ft2,1,, -Miscellaneous Spaces,General manufacturing (excludes heavy industrial and processes using chemicals),10,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,3,, -Miscellaneous Spaces,Pharmacy (prep. area),5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, -Miscellaneous Spaces,Photo studios,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, -Miscellaneous Spaces,Shipping/receiving,10,cfm/person,0.12,cfm/ft2,2,ppl/1000 ft2,2,, -Miscellaneous Spaces,"Sorting, packing, light assembly",7.5,cfm/person,0.12,cfm/ft2,7,ppl/1000 ft2,2,, -Miscellaneous Spaces,Telephone closets,0,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,1,, -Miscellaneous Spaces,Transportation waiting,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, -Miscellaneous Spaces,Warehouses,10,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,2,, -Public Assembly Spaces,Auditorium seating area,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -Public Assembly Spaces,Places of religious workshop,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,, -Public Assembly Spaces,Courtrooms,5,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, -Public Assembly Spaces,Legislative chambers,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, -Public Assembly Spaces,Libraries,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, -Public Assembly Spaces,Lobbies,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -Public Assembly Spaces,Museums (children's),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, -Public Assembly Spaces,Museums/galleries,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, -Residential,Dwelling unit,5,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, -Residential,Common corridors,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, -Retail,Sales (except as below),7.5,cfm/person,0.12,cfm/ft2,15,ppl/1000 ft2,2,, -Retail,Mall common areas,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, -Retail,Barbershop,7.5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,2,, -Retail,Beauty and nail salons,20,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, -Retail,Pet shops (animal areas),7.5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, -Retail,Supermarket,7.5,cfm/person,0.06,cfm/ft2,8,ppl/1000 ft2,1,, -Retail,Coin-operated laundries,7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2,, -Sports and Entertainment,Sports arena (play area),0,cfm/person,0.3,cfm/ft2,0,ppl/1000 ft2,1,, -Sports and Entertainment,"Gym, stadium (play area)",0,cfm/person,0.3,cfm/ft2,30,ppl/1000 ft2,2,, -Sports and Entertainment,Spectator areas,7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -Sports and Entertainment,Swimming (pool & deck),0,cfm/person,0.48,cfm/ft2,0,ppl/1000 ft2,2,, -Sports and Entertainment,Disco/dance floors,20,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,2,, -Sports and Entertainment,Health club/aerobics room,20,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,2,, -Sports and Entertainment,Health club/weight rooms,20,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,2,, -Sports and Entertainment,Bowling alley (seating),10,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, -Sports and Entertainment,Gambling casinos,7.5,cfm/person,0.18,cfm/ft2,120,ppl/1000 ft2,1,, -Sports and Entertainment,Game arcades,7.5,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, -Sports and Entertainment,"Stages, studios",10,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, -None,None,0,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,,, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2013.csv b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2013.csv deleted file mode 100644 index 2db1b9a31f..0000000000 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2013.csv +++ /dev/null @@ -1,80 +0,0 @@ -ventilation_primary_space_type,ventilation_secondary_space_type,ventilation_rate_occupant,ventilation_rate_occupant_unit,ventilation_rate_area,ventilation_rate_area_unit,occupancy_per_area,occupancy_per_area_unit,air_class,os,annotation -Correctional Facilities,Cell,5,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, -Correctional Facilities,Dayroom,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, -Correctional Facilities,Guard stations,5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,, -Correctional Facilities,Booking/waiting,7.5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,2,, -Educational Facilities,Daycare (through age 4),10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, -Educational Facilities,Daycare sickroom,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,3,, -Educational Facilities,Classrooms (ages 5-8),10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, -Educational Facilities,Classrooms (age 9 plus),10,cfm/person,0.12,cfm/ft2,35,ppl/1000 ft2,1,, -Educational Facilities,Lecture classroom,7.5,cfm/person,0.06,cfm/ft2,65,ppl/1000 ft2,1,, -Educational Facilities,Lecture hall (fixed seats),7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -Educational Facilities,Art classroom,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, -Educational Facilities,Science laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, -Educational Facilities,University/college laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, -Educational Facilities,Wood/metal shop,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, -Educational Facilities,Computer lab,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, -Educational Facilities,Media center,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, -Educational Facilities,Music/theater/dance,10,cfm/person,0.06,cfm/ft2,35,ppl/1000 ft2,1,, -Educational Facilities,Multiuse assembly,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, -Food and Beverage Service,Restaurant dining rooms,7.5,cfm/person,0.18,cfm/ft2,70,ppl/1000 ft2,2,, -Food and Beverage Service,Cafeteria/fast-food dining,7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, -Food and Beverage Service,"Bars, cocktail lounges",7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, -Food and Beverage Service,Kitchen (cooking),7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2,, -General,Break rooms,5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,1,, -General,Coffee stations,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, -General,Conference/meeting,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, -General,Corridors,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, -General,Occupiable storage rooms for liquids or gels,5,cfm/person,0.12,cfm/ft2,2,ppl/1000 ft2,2,, -"Hotels, Motels, Resorts, Dormitories",Bedroom/living Room,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,, -"Hotels, Motels, Resorts, Dormitories",Barracks sleeping areas,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, -"Hotels, Motels, Resorts, Dormitories","Laundry rooms, central",5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,2,, -"Hotels, Motels, Resorts, Dormitories",Laundry rooms within dwelling units,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, -"Hotels, Motels, Resorts, Dormitories",Lobbies/prefunction,7.5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, -"Hotels, Motels, Resorts, Dormitories",Multipurpose assembly,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,, -Miscellaneous Spaces,Bank vaults/safe deposit,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,2,, -Miscellaneous Spaces,Banks or bank lobbies,7.5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,, -Miscellaneous Spaces,Computer (not printing),5,cfm/person,0.06,cfm/ft2,4,ppl/1000 ft2,1,, -Miscellaneous Spaces,Freezer and refrigerated spaces (<50degF),10,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,2,, -Miscellaneous Spaces,General manufacturing (excludes heavy industrial and processes using chemicals),10,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,3,, -Miscellaneous Spaces,Pharmacy (prep. area),5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, -Miscellaneous Spaces,Photo studios,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, -Miscellaneous Spaces,Shipping/receiving,10,cfm/person,0.12,cfm/ft2,2,ppl/1000 ft2,2,, -Miscellaneous Spaces,"Sorting, packing, light assembly",7.5,cfm/person,0.12,cfm/ft2,7,ppl/1000 ft2,2,, -Miscellaneous Spaces,Telephone closets,0,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,1,, -Miscellaneous Spaces,Transportation waiting,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, -Miscellaneous Spaces,Warehouses,10,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,2,, -Office Buildings,Breakrooms,5,cfm/person,0.12,cfm/ft2,50,ppl/1000 ft2,1,, -Office Buildings,Main entry lobbies,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,, -Office Buildings,Occupiable storage rooms for dry materials,5,cfm/person,0.06,cfm/ft2,2,ppl/1000 ft2,1,, -Office Buildings,Office space,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1,, -Office Buildings,Reception areas,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, -Office Buildings,Telephone/data entry,5,cfm/person,0.06,cfm/ft2,60,ppl/1000 ft2,1,, -Public Assembly Spaces,Auditorium seating area,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -Public Assembly Spaces,Places of religious workshop,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,, -Public Assembly Spaces,Courtrooms,5,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, -Public Assembly Spaces,Legislative chambers,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, -Public Assembly Spaces,Libraries,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, -Public Assembly Spaces,Lobbies,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -Public Assembly Spaces,Museums (children's),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, -Public Assembly Spaces,Museums/galleries,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, -Residential,Dwelling unit,5,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, -Residential,Common corridors,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, -Retail,Sales (except as below),7.5,cfm/person,0.12,cfm/ft2,15,ppl/1000 ft2,2,, -Retail,Mall common areas,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, -Retail,Barbershop,7.5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,2,, -Retail,Beauty and nail salons,20,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, -Retail,Pet shops (animal areas),7.5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, -Retail,Supermarket,7.5,cfm/person,0.06,cfm/ft2,8,ppl/1000 ft2,1,, -Retail,Coin-operated laundries,7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2,, -Sports and Entertainment,"Gym, sports arena (play area)",20,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,2,, -Sports and Entertainment,Spectator areas,7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -Sports and Entertainment,Swimming (pool & deck),0,cfm/person,0.48,cfm/ft2,0,ppl/1000 ft2,2,, -Sports and Entertainment,Disco/dance floors,20,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,2,, -Sports and Entertainment,Health club/aerobics room,20,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,2,, -Sports and Entertainment,Health club/weight rooms,20,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,2,, -Sports and Entertainment,Bowling alley (seating),10,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, -Sports and Entertainment,Gambling casinos,7.5,cfm/person,0.18,cfm/ft2,120,ppl/1000 ft2,1,, -Sports and Entertainment,Game arcades,7.5,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, -Sports and Entertainment,"Stages, studios",10,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, -None,None,0,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,,, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2016.csv b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2016.csv deleted file mode 100644 index 2db1b9a31f..0000000000 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2016.csv +++ /dev/null @@ -1,80 +0,0 @@ -ventilation_primary_space_type,ventilation_secondary_space_type,ventilation_rate_occupant,ventilation_rate_occupant_unit,ventilation_rate_area,ventilation_rate_area_unit,occupancy_per_area,occupancy_per_area_unit,air_class,os,annotation -Correctional Facilities,Cell,5,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, -Correctional Facilities,Dayroom,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, -Correctional Facilities,Guard stations,5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,, -Correctional Facilities,Booking/waiting,7.5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,2,, -Educational Facilities,Daycare (through age 4),10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, -Educational Facilities,Daycare sickroom,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,3,, -Educational Facilities,Classrooms (ages 5-8),10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, -Educational Facilities,Classrooms (age 9 plus),10,cfm/person,0.12,cfm/ft2,35,ppl/1000 ft2,1,, -Educational Facilities,Lecture classroom,7.5,cfm/person,0.06,cfm/ft2,65,ppl/1000 ft2,1,, -Educational Facilities,Lecture hall (fixed seats),7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -Educational Facilities,Art classroom,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, -Educational Facilities,Science laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, -Educational Facilities,University/college laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, -Educational Facilities,Wood/metal shop,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, -Educational Facilities,Computer lab,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, -Educational Facilities,Media center,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, -Educational Facilities,Music/theater/dance,10,cfm/person,0.06,cfm/ft2,35,ppl/1000 ft2,1,, -Educational Facilities,Multiuse assembly,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, -Food and Beverage Service,Restaurant dining rooms,7.5,cfm/person,0.18,cfm/ft2,70,ppl/1000 ft2,2,, -Food and Beverage Service,Cafeteria/fast-food dining,7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, -Food and Beverage Service,"Bars, cocktail lounges",7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, -Food and Beverage Service,Kitchen (cooking),7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2,, -General,Break rooms,5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,1,, -General,Coffee stations,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, -General,Conference/meeting,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, -General,Corridors,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, -General,Occupiable storage rooms for liquids or gels,5,cfm/person,0.12,cfm/ft2,2,ppl/1000 ft2,2,, -"Hotels, Motels, Resorts, Dormitories",Bedroom/living Room,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,, -"Hotels, Motels, Resorts, Dormitories",Barracks sleeping areas,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, -"Hotels, Motels, Resorts, Dormitories","Laundry rooms, central",5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,2,, -"Hotels, Motels, Resorts, Dormitories",Laundry rooms within dwelling units,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, -"Hotels, Motels, Resorts, Dormitories",Lobbies/prefunction,7.5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, -"Hotels, Motels, Resorts, Dormitories",Multipurpose assembly,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,, -Miscellaneous Spaces,Bank vaults/safe deposit,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,2,, -Miscellaneous Spaces,Banks or bank lobbies,7.5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,, -Miscellaneous Spaces,Computer (not printing),5,cfm/person,0.06,cfm/ft2,4,ppl/1000 ft2,1,, -Miscellaneous Spaces,Freezer and refrigerated spaces (<50degF),10,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,2,, -Miscellaneous Spaces,General manufacturing (excludes heavy industrial and processes using chemicals),10,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,3,, -Miscellaneous Spaces,Pharmacy (prep. area),5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, -Miscellaneous Spaces,Photo studios,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, -Miscellaneous Spaces,Shipping/receiving,10,cfm/person,0.12,cfm/ft2,2,ppl/1000 ft2,2,, -Miscellaneous Spaces,"Sorting, packing, light assembly",7.5,cfm/person,0.12,cfm/ft2,7,ppl/1000 ft2,2,, -Miscellaneous Spaces,Telephone closets,0,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,1,, -Miscellaneous Spaces,Transportation waiting,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,, -Miscellaneous Spaces,Warehouses,10,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,2,, -Office Buildings,Breakrooms,5,cfm/person,0.12,cfm/ft2,50,ppl/1000 ft2,1,, -Office Buildings,Main entry lobbies,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,, -Office Buildings,Occupiable storage rooms for dry materials,5,cfm/person,0.06,cfm/ft2,2,ppl/1000 ft2,1,, -Office Buildings,Office space,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1,, -Office Buildings,Reception areas,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, -Office Buildings,Telephone/data entry,5,cfm/person,0.06,cfm/ft2,60,ppl/1000 ft2,1,, -Public Assembly Spaces,Auditorium seating area,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -Public Assembly Spaces,Places of religious workshop,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,, -Public Assembly Spaces,Courtrooms,5,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, -Public Assembly Spaces,Legislative chambers,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, -Public Assembly Spaces,Libraries,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, -Public Assembly Spaces,Lobbies,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -Public Assembly Spaces,Museums (children's),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, -Public Assembly Spaces,Museums/galleries,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, -Residential,Dwelling unit,5,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, -Residential,Common corridors,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,, -Retail,Sales (except as below),7.5,cfm/person,0.12,cfm/ft2,15,ppl/1000 ft2,2,, -Retail,Mall common areas,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,, -Retail,Barbershop,7.5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,2,, -Retail,Beauty and nail salons,20,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, -Retail,Pet shops (animal areas),7.5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, -Retail,Supermarket,7.5,cfm/person,0.06,cfm/ft2,8,ppl/1000 ft2,1,, -Retail,Coin-operated laundries,7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2,, -Sports and Entertainment,"Gym, sports arena (play area)",20,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,2,, -Sports and Entertainment,Spectator areas,7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,, -Sports and Entertainment,Swimming (pool & deck),0,cfm/person,0.48,cfm/ft2,0,ppl/1000 ft2,2,, -Sports and Entertainment,Disco/dance floors,20,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,2,, -Sports and Entertainment,Health club/aerobics room,20,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,2,, -Sports and Entertainment,Health club/weight rooms,20,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,2,, -Sports and Entertainment,Bowling alley (seating),10,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, -Sports and Entertainment,Gambling casinos,7.5,cfm/person,0.18,cfm/ft2,120,ppl/1000 ft2,1,, -Sports and Entertainment,Game arcades,7.5,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, -Sports and Entertainment,"Stages, studios",10,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,, -None,None,0,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,,, diff --git a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.csv b/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.csv deleted file mode 100644 index acfc66fb48..0000000000 --- a/data/openstudio_standards_data/database_files/level_3_ventilation_62_1_2019.csv +++ /dev/null @@ -1,111 +0,0 @@ -ventilation_primary_space_type,ventilation_secondary_space_type,ventilation_rate_occupant,ventilation_rate_occupant_unit,ventilation_rate_area,ventilation_rate_area_unit,occupancy_per_area,occupancy_per_area_unit,air_class,os,annotation -Animal Facilities,Animal exam room (veterinary office),10,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2,, -Animal Facilities,Animal imaging (MRI/CT/PET),10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, -Animal Facilities,Animal operating rooms,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, -Animal Facilities,Animal postoperative recovery room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, -Animal Facilities,Animal preparation rooms,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, -Animal Facilities,Animal procedure room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, -Animal Facilities,Animal surgery scrub,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, -Animal Facilities,Large-animal holding room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, -Animal Facilities,Necropsy,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, -Animal Facilities,Small-animal-cage room (static cages),10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, -Animal Facilities,Small-animal-cage room (ventilated cages),10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,3,, -Correctional Facilities,Booking/waiting,7.5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,2,, -Correctional Facilities,Cell,5,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, -Correctional Facilities,Dayroom,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,, -Correctional Facilities,Guard stations,5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,, -Educational Facilities,Art classroom,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, -Educational Facilities,Classrooms (ages 5 to 8),10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, -Educational Facilities,Classrooms (age 9 plus),10,cfm/person,0.12,cfm/ft2,35,ppl/1000 ft2,1,, -Educational Facilities,Computer lab,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, -Educational Facilities,Daycare sickroom,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,3,, -Educational Facilities,Daycare (through age 4),10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, -Educational Facilities,Lecture classroom,7.5,cfm/person,0.06,cfm/ft2,65,ppl/1000 ft2,1,yes, -Educational Facilities,Lecture hall (fixed seats),7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,yes, -Educational Facilities,Libraries (education),5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,,, -Educational Facilities,Media center,10,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,1,, -Educational Facilities,Multiuse assembly,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,yes, -Educational Facilities,Music/theater/dance,10,cfm/person,0.06,cfm/ft2,35,ppl/1000 ft2,1,yes, -Educational Facilities,Science laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, -Educational Facilities,University/college laboratories,10,cfm/person,0.18,cfm/ft2,25,ppl/1000 ft2,2,, -Educational Facilities,Wood/metal shop,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,2,, -Food and Beverage Service,"Bars, cocktail lounges",7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, -Food and Beverage Service,Cafeteria/fast-food dining,7.5,cfm/person,0.18,cfm/ft2,100,ppl/1000 ft2,2,, -Food and Beverage Service,Kitchen (cooking),7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2,, -Food and Beverage Service,Restaurant dining rooms,7.5,cfm/person,0.18,cfm/ft2,70,ppl/1000 ft2,2,, -"Food and Beverage Service, General",Break rooms,5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,1,yes, -"Food and Beverage Service, General",Coffee stations,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,yes, -"Food and Beverage Service, General",Conference/meeting,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,yes, -"Food and Beverage Service, General",Corridors,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,yes, -"Food and Beverage Service, General",Occupiable storage rooms for liquids or gels,5,cfm/person,0.12,cfm/ft2,2,ppl/1000 ft2,2,, -"Hotels, Motels, Resorts, Dormitories",Barracks sleeping areas,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,yes, -"Hotels, Motels, Resorts, Dormitories",Bedroom/living room,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,yes, -"Hotels, Motels, Resorts, Dormitories","Laundry rooms, central",5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,2,, -"Hotels, Motels, Resorts, Dormitories",Laundry rooms within dwelling units,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, -"Hotels, Motels, Resorts, Dormitories",Lobbies/prefunction,7.5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,yes, -"Hotels, Motels, Resorts, Dormitories",Multipurpose assembly,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,yes, -Miscellaneous Spaces,Banks or bank lobbies,7.5,cfm/person,0.06,cfm/ft2,15,ppl/1000 ft2,1,yes, -Miscellaneous Spaces,Bank vaults/safe deposit,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,2,yes, -Miscellaneous Spaces,Computer (not printing),5,cfm/person,0.06,cfm/ft2,4,ppl/1000 ft2,1,yes, -Miscellaneous Spaces,Freezer and refrigerated spaces (<50degF [10degC]),10,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,2,, -Miscellaneous Spaces,Manufacturing where hazardous materials are not used,10,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,2,, -Miscellaneous Spaces,Manufacturing where hazardous materials are used (excludes heavy industrial and chemical processes),10,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,3,, -Miscellaneous Spaces,Pharmacy (prep. area),5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, -Miscellaneous Spaces,Photo studios,5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, -Miscellaneous Spaces,Shipping/receiving,10,cfm/person,0.12,cfm/ft2,2,ppl/1000 ft2,2,, -Miscellaneous Spaces,"Sorting, packing, light assembly",7.5,cfm/person,0.12,cfm/ft2,7,ppl/1000 ft2,2,, -Miscellaneous Spaces,Telephone closets,0,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,1,, -Miscellaneous Spaces,Transportation waiting,7.5,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,1,yes, -Miscellaneous Spaces,Warehouses,10,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,2,, -Office Buildings,Breakrooms,5,cfm/person,0.12,cfm/ft2,50,ppl/1000 ft2,1,, -Office Buildings,Main entry lobbies,5,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,1,yes, -Office Buildings,Occupiable storage rooms for dry materials,5,cfm/person,0.06,cfm/ft2,2,ppl/1000 ft2,1,, -Office Buildings,Office space,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1,yes, -Office Buildings,Reception areas,5,cfm/person,0.06,cfm/ft2,30,ppl/1000 ft2,1,yes, -Office Buildings,Telephone/data entry,5,cfm/person,0.06,cfm/ft2,60,ppl/1000 ft2,1,yes, -Outpatient Health Care Facilities,Birthing room,10,cfm/person,0.18,cfm/ft2,15,ppl/1000 ft2,2,, -Outpatient Health Care Facilities,Class 1 imaging rooms,5,cfm/person,0.12,cfm/ft2,5,ppl/1000 ft2,1,, -Outpatient Health Care Facilities,Dental operatory,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, -Outpatient Health Care Facilities,General examination room,7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,1,, -Outpatient Health Care Facilities,Other dental treatment areas,5,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1,, -Outpatient Health Care Facilities,Physical therapy exercise area,20,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,2,, -Outpatient Health Care Facilities,Physical therapy individual room,10,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, -Outpatient Health Care Facilities,Physical therapeutic pool area,0,cfm/person,0.48,cfm/ft2,0,ppl/1000 ft2,2,, -Outpatient Health Care Facilities,Prosthetics and orthotics room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, -Outpatient Health Care Facilities,Psychiatric consultation room,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, -Outpatient Health Care Facilities,Psychiatric examination room,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, -Outpatient Health Care Facilities,Psychiatric group room,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,, -Outpatient Health Care Facilities,Psychiatric seclusion room,10,cfm/person,0.06,cfm/ft2,5,ppl/1000 ft2,1,, -Outpatient Health Care Facilities,Speech therapy room,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, -Outpatient Health Care Facilities,Urgent care examination room,7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,1,, -Outpatient Health Care Facilities,Urgent care observation room,5,cfm/person,0.06,cfm/ft2,20,ppl/1000 ft2,1,, -Outpatient Health Care Facilities,Urgent care treatment room,7.5,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, -Outpatient Health Care Facilities,Urgent care triage room,10,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, -Public Assembly Spaces,Auditorium seating area,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,yes, -Public Assembly Spaces,Courtrooms,5,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,yes, -Public Assembly Spaces,Legislative chambers,5,cfm/person,0.06,cfm/ft2,50,ppl/1000 ft2,1,yes, -Public Assembly Spaces,Libraries (public assembly),5,cfm/person,0.12,cfm/ft2,10,ppl/1000 ft2,1,, -Public Assembly Spaces,Lobbies,5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,yes, -Public Assembly Spaces,Museums (children's),7.5,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, -Public Assembly Spaces,Museums/galleries,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,yes, -Public Assembly Spaces,Places of religious worship,5,cfm/person,0.06,cfm/ft2,120,ppl/1000 ft2,1,yes, -Retail,Sales (except as below),7.5,cfm/person,0.12,cfm/ft2,15,ppl/1000 ft2,2,, -Retail,Barbershop,7.5,cfm/person,0.06,cfm/ft2,25,ppl/1000 ft2,2,yes, -Retail,Beauty and nail salons,20,cfm/person,0.12,cfm/ft2,25,ppl/1000 ft2,2,, -Retail,Coin-operated laundries,7.5,cfm/person,0.12,cfm/ft2,20,ppl/1000 ft2,2,, -Retail,Mall common areas,7.5,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,1,yes, -Retail,Pet shops (animal areas),7.5,cfm/person,0.18,cfm/ft2,10,ppl/1000 ft2,2,, -Retail,Supermarket,7.5,cfm/person,0.06,cfm/ft2,8,ppl/1000 ft2,1,yes, -Sports and Entertainment,Bowling alley (seating),10,cfm/person,0.12,cfm/ft2,40,ppl/1000 ft2,1,, -Sports and Entertainment,Disco/dance floors,20,cfm/person,0.06,cfm/ft2,100,ppl/1000 ft2,2,yes, -Sports and Entertainment,Gambling casinos,7.5,cfm/person,0.18,cfm/ft2,120,ppl/1000 ft2,1,, -Sports and Entertainment,Game arcades,7.5,cfm/person,0.18,cfm/ft2,20,ppl/1000 ft2,1,, -Sports and Entertainment,"Gym, sports arena (play area)",20,cfm/person,0.18,cfm/ft2,7,ppl/1000 ft2,2,, -Sports and Entertainment,Health club/aerobics room,20,cfm/person,0.06,cfm/ft2,40,ppl/1000 ft2,2,, -Sports and Entertainment,Health club/weight rooms,20,cfm/person,0.06,cfm/ft2,10,ppl/1000 ft2,2,, -Sports and Entertainment,Spectator areas,7.5,cfm/person,0.06,cfm/ft2,150,ppl/1000 ft2,1,yes, -Sports and Entertainment,"Stages, studios",10,cfm/person,0.06,cfm/ft2,70,ppl/1000 ft2,1,yes, -Sports and Entertainment,Swimming (pool and deck),0,cfm/person,0.48,cfm/ft2,0,ppl/1000 ft2,2,, -Transient Residential,Common corridors,0,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,yes, -Transient Residential,Dwelling unit,5,cfm/person,0.06,cfm/ft2,0,ppl/1000 ft2,1,yes, -None,None,0,cfm/person,0,cfm/ft2,0,ppl/1000 ft2,,, diff --git a/data/openstudio_standards_data/database_files/support_constructions.csv b/data/openstudio_standards_data/database_files/support_constructions.csv deleted file mode 100644 index add7bb239f..0000000000 --- a/data/openstudio_standards_data/database_files/support_constructions.csv +++ /dev/null @@ -1,492 +0,0 @@ -name,intended_surface_type,standards_construction_type,insulation_layer,skylight_framing,material_1,material_2,material_3,material_4,material_5,material_6 -Typical Attic Floor,AtticFloor,WoodFramed,Typical Insulation,,1/2IN Gypsum,Typical Insulation,1/2IN Gypsum,,, -Typical Wood Joist Attic Floor,AtticFloor,WoodFramed,Typical Insulation,,5/8 in. Gypsum Board,Typical Insulation,,,, -Typical Wood Joist Attic Floor Ceiling,AtticFloor,WoodFramed,,,Typical Insulation,5/8 in. Gypsum Board,,,, -Typical Uninsulated Metal Roof Attic Roof,AtticRoof,WoodFramed,,,Roof Membrane,Metal Decking,,,, -Typical Uninsulated Wood Joist Attic Roof,AtticRoof,WoodFramed,,,Asphalt Shingles,5/8 in. Plywood,,,, -Typical Attic Soffit,AtticWall,,,,5/8 in. Plywood,,,,, -Typical Insulated Metal Door,ExteriorDoor,,Typical Insulation,,F08 Metal surface,Typical Insulation,,,, -Typical Overhead Door,ExteriorDoor,RollUp,Typical Insulation,,Typical Insulation,,,,, -Typical Uninsulated Swinging Door,ExteriorDoor,Swinging,Typical Insulation,,Typical Insulation,,,,, -Adiabatic ExteriorFloor,ExteriorFloor,Mass,,,Adiabatic Material,,,,, -Typical Carpeted 4in Slab Floor,ExteriorFloor,,,,MAT-CC05 4 HW CONCRETE,Typical Carpet Pad,,,, -Typical Insulated Carpeted 4in Slab Floor,ExteriorFloor,,Typical Insulation,,Typical Insulation,MAT-CC05 4 HW CONCRETE,Typical Carpet Pad,,, -Typical Insulated Exterior Mass Floor,ExteriorFloor,Mass,Typical Insulation,,Typical Insulation,4 in. Normalweight Concrete Floor,Typical Carpet Pad,,, -Typical Insulated Exterior Mass Floor Ceiling,ExteriorFloor,Mass,Typical Insulation,,Typical Carpet Pad,4 in. Normalweight Concrete Floor,Typical Insulation,,, -Typical Insulated Steel Framed Exterior Floor,ExteriorFloor,SteelFramed,Typical Insulation,,25mm Stucco,5/8 in. Gypsum Board,Typical Insulation,5/8 in. Gypsum Board,Typical Carpet Pad, -Typical Insulated Wood Framed Exterior Floor,ExteriorFloor,WoodFramed,Typical Insulation,,25mm Stucco,5/8 in. Gypsum Board,Typical Insulation,5/8 in. Gypsum Board,Typical Carpet Pad, -Typical Uncarpeted 4in Slab Floor,ExteriorFloor,,,,MAT-CC05 4 HW CONCRETE,,,,, -Adiabatic Roof,ExteriorRoof,Attic and Other,,,Adiabatic Material,,,,, -Metal roofR_R30,ExteriorRoof,,Typical Insulation,,Metal Standing Seam - 1/16 in. CBES,R_R30,,,, -Metal roofR_R38,ExteriorRoof,,Typical Insulation,,Metal Standing Seam - 1/16 in. CBES,R_R38,,,, -Metal roofR_T24_2013_24.86,ExteriorRoof,,Typical Insulation,,Metal Standing Seam - 1/16 in. CBES,R_T24_2013_24.86,,,, -Metal roofR1_R14.20,ExteriorRoof,,Typical Insulation,,Metal Standing Seam - 1/16 in. CBES,R1_R14.20,,,, -Metal roofR2_R12.90,ExteriorRoof,,Typical Insulation,,Metal Standing Seam - 1/16 in. CBES,R2_R12.90,,,, -Metal roofR3_R17.74,ExteriorRoof,,Typical Insulation,,Metal Standing Seam - 1/16 in. CBES,R3_R17.74,,,, -Metal roofR4_R20.28,ExteriorRoof,,Typical Insulation,,Metal Standing Seam - 1/16 in. CBES,R4_R20.28,,,, -Typical Built Up Roof,ExteriorRoof,IEAD,Typical Insulation,,Built-up Roofing,Typical Insulation,Metal Surface,,, -Typical Built Up Roof - Highly Reflective,ExteriorRoof,IEAD,Typical Insulation,,Built-up Roofing - Highly Reflective,Typical Insulation,Metal Surface,,, -Typical IEAD Roof,ExteriorRoof,IEAD,Typical Insulation,,Roof Membrane,Typical Insulation,Metal Roof Surface,,, -Typical IEAD Roof - Highly Reflective,ExteriorRoof,IEAD,Typical Insulation,,Roof Membrane - Highly Reflective,Typical Insulation,Metal Roof Surface,,, -Typical Insulated Metal Building Roof,ExteriorRoof,Metal Building,Typical Insulation,,Metal Roof Surface,Typical Insulation,,,, -Typical Insulated Metal Building Roof - Highly Reflective,ExteriorRoof,Metal Building,Typical Insulation,,Metal Roof Surface - Highly Reflective,Typical Insulation,,,, -Typical Uninsulated Metal Building Roof,ExteriorRoof,Metal Building,,,Metal Roofing,,,,, -Typical Uninsulated Metal Building Roof - Highly Reflective,ExteriorRoof,Metal Building,,,Metal Roofing - Highly Reflective,,,,, -Adiabatic Wall,ExteriorWall,Mass,,,Adiabatic Material,,,,, -Metal framed wallsW_m1_R15,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W_m1_R15,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, -Metal framed wallsW_m2_R19,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W_m2_R19,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, -Metal framed wallsW_m3_R21,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W_m3_R21,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, -Metal framed wallsW_T24_2013_R13.99,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W_T24_2013_R13.99,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, -Metal framed wallsW1_R8.60,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W1_R8.60,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, -Metal framed wallsW2_R11.13,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W2_R11.13,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, -Metal framed wallsW3_R11.36,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W3_R11.36,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, -Metal framed wallsW4_R12.62,ExteriorWall,,Typical Insulation,,Stucco - 7/8 in. CBES,W4_R12.62,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 1/2 in. CBES,, -Typical Insulated Exterior Mass Wall,ExteriorWall,Mass,Typical Insulation,,1IN Stucco,8IN CONCRETE HW RefBldg,Typical Insulation,1/2IN Gypsum,, -Typical Insulated Metal Building Wall,ExteriorWall,Metal Building,Typical Insulation,,Metal Siding,Typical Insulation,1/2IN Gypsum,,, -Typical Insulated Steel Framed Exterior Wall,ExteriorWall,SteelFramed,Typical Insulation,,25mm Stucco,5/8 in. Gypsum Board,Typical Insulation,5/8 in. Gypsum Board,, -Typical Insulated Wood Framed Exterior Wall,ExteriorWall,WoodFramed,Typical Insulation,,25mm Stucco,5/8 in. Gypsum Board,Typical Insulation,5/8 in. Gypsum Board,, -Typical Uninsulated Exterior Mass Wall,ExteriorWall,Mass,,,1IN Stucco,8IN CONCRETE HW RefBldg,1/2IN Gypsum,,, -Typical Uninsulated Metal Building Wall,ExteriorWall,Metal Building,,,Metal Siding,1/2IN Gypsum,,,, -Typical Uninsulated Steel Framed Exterior Wall,ExteriorWall,SteelFramed,,,Wood Siding,1/2IN Gypsum,,,, -WoodWallU110,ExteriorWall,,,,Plywood - 5/8 in.,Compliance Insulation R6.46,Air - Metal Wall Framing - 16 or 24 in. OC,Gypsum Board - 3/8 in.,, -ASHRAE 189.1-2009 ExtWindow ClimateZone 1,ExteriorWindow,,,,Theoretical Glass [167],,,,, -ASHRAE 189.1-2009 ExtWindow ClimateZone 2,ExteriorWindow,,,,Theoretical Glass [197],,,,, -ASHRAE 189.1-2009 ExtWindow ClimateZone 3,ExteriorWindow,,,,Theoretical Glass [202],,,,, -ASHRAE 189.1-2009 ExtWindow ClimateZone 4-5,ExteriorWindow,,,,Theoretical Glass [207],,,,, -ASHRAE 189.1-2009 ExtWindow ClimateZone 6,ExteriorWindow,,,,Theoretical Glass [216],,,,, -ASHRAE 189.1-2009 ExtWindow ClimateZone 7-8,ExteriorWindow,,,,Theoretical Glass [221],,,,, -ASHRAE 189.1-2009 ExtWindow ClimateZone alt-res 4-5,ExteriorWindow,,,,Theoretical Glass [216],,,,, -U 0.11 SHGC 0.34 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.11 SHGC 0.34 Simple Glazing,,,,, -U 0.11 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.11 SHGC 0.38 Simple Glazing,,,,, -U 0.12 SHGC 0.34 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.12 SHGC 0.34 Simple Glazing,,,,, -U 0.12 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.12 SHGC 0.38 Simple Glazing,,,,, -U 0.13 SHGC 0.32 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.13 SHGC 0.32 Simple Glazing,,,,, -U 0.13 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.13 SHGC 0.38 Simple Glazing,,,,, -U 0.14 SHGC 0.31 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.14 SHGC 0.31 Simple Glazing,,,,, -U 0.14 SHGC 0.34 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.14 SHGC 0.34 Simple Glazing,,,,, -U 0.14 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.14 SHGC 0.36 Simple Glazing,,,,, -U 0.14 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.14 SHGC 0.38 Simple Glazing,,,,, -U 0.15 SHGC 0.31 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.15 SHGC 0.31 Simple Glazing,,,,, -U 0.15 SHGC 0.34 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.15 SHGC 0.34 Simple Glazing,,,,, -U 0.17 SHGC 0.31 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.17 SHGC 0.31 Simple Glazing,,,,, -U 0.17 SHGC 0.32 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.17 SHGC 0.32 Simple Glazing,,,,, -U 0.17 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.17 SHGC 0.36 Simple Glazing,,,,, -U 0.18 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.18 SHGC 0.22 Simple Glazing,,,,, -U 0.18 SHGC 0.24 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.18 SHGC 0.24 Simple Glazing,,,,, -U 0.19 SHGC 0.20 Trp LoE Film (55) Bronze 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,BRONZE 6MM,AIR 13MM,COATED POLY-55,AIR 13MM,CLEAR 3MM, -U 0.20 SHGC 0.19 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.20 SHGC 0.19 Simple Glazing,,,,, -U 0.20 SHGC 0.20 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.20 SHGC 0.20 Simple Glazing,,,,, -U 0.20 SHGC 0.21 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.20 SHGC 0.21 Simple Glazing,,,,, -U 0.20 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.20 SHGC 0.22 Simple Glazing,,,,, -U 0.23 SHGC 0.31 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.23 SHGC 0.31 Simple Glazing,,,,, -U 0.23 SHGC 0.34 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.23 SHGC 0.34 Simple Glazing,,,,, -U 0.24 SHGC 0.11 Dbl LoE Elec Abs Colored 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,ECABS-2 COLORED 6MM,ARGON 13MM,LoE SPEC SEL CLEAR 6MM Rev,,, -U 0.24 SHGC 0.16 Dbl Elec Abs Colored 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,ECABS-2 COLORED 6MM,ARGON 13MM,CLEAR 6MM,,, -U 0.24 SHGC 0.23 Dbl LoE Spec Sel Tint 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,LoE SPEC SEL TINT 6MM,ARGON 13MM,CLEAR 6MM,,, -U 0.25 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.25 SHGC 0.22 Simple Glazing,,,,, -U 0.25 SHGC 0.24 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.25 SHGC 0.24 Simple Glazing,,,,, -U 0.25 SHGC 0.40 Dbl LoE (e2-.1) Tint 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,LoE TINT 6MM,ARGON 13MM,CLEAR 6MM,,, -U 0.26 SHGC 0.40 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.26 SHGC 0.40 Simple Glazing,,,,, -U 0.29 SHGC 0.11 Dbl LoE Elec Ref Colored 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,ECREF-2 COLORED 6MM,AIR 13MM,LoE SPEC SEL CLEAR 6MM Rev,,, -U 0.29 SHGC 0.17 Dbl Elec Abs Colored 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,ECABS-2 COLORED 6MM,AIR 13MM,CLEAR 6MM,,, -U 0.29 SHGC 0.22 Trp LoE Film (55) Bronze 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,BRONZE 6MM,AIR 6MM,COATED POLY-55,AIR 6MM,CLEAR 3MM, -U 0.29 SHGC 0.40 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.29 SHGC 0.40 Simple Glazing,,,,, -U 0.30 SHGC 0.40 Dbl LoE (e2-.1) Tint 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,LoE TINT 6MM,AIR 13MM,CLEAR 6MM,,, -U 0.32 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.32 SHGC 0.36 Simple Glazing,,,,, -U 0.33 SHGC 0.11 Dbl LoE Elec Ref Colored 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,ECREF-2 COLORED 6MM,AIR 13MM,LoE SPEC SEL CLEAR 6MM Rev,,, -U 0.33 SHGC 0.40 Dbl LoE (e2-.1) Tint 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,LoE TINT 6MM,AIR 13MM,CLEAR 6MM,,, -U 0.33 SHGC 0.45 Trp LoE Film (77) Clr 3mm/6mm Air,ExteriorWindow,Metal framing (all other),,,CLEAR 3MM,AIR 6MM,COATED POLY-77,AIR 6MM,CLEAR 3MM, -U 0.34 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.34 SHGC 0.38 Simple Glazing,,,,, -U 0.34 SHGC 0.40 Dbl LoE (e2-.1) Tint 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,LoE TINT 6MM,AIR 13MM,CLEAR 6MM,,, -U 0.34 SHGC 0.45 Dbl LoE (e2-.2) Clr 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,PYR B CLEAR 6MM,AIR 13MM,CLEAR 6MM,,, -U 0.35 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.35 SHGC 0.22 Simple Glazing,,,,, -U 0.35 SHGC 0.24 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.35 SHGC 0.24 Simple Glazing,,,,, -U 0.35 SHGC 0.26 Dbl Ref-C-M Clr 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,REF C CLEAR MID 6MM,ARGON 13MM,CLEAR 6MM,,, -U 0.35 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,LoE TINT 6MM,AIR 13MM,CLEAR 6MM,,, -U 0.36 SHGC 0.35 Dbl LoE Spec Sel Tint 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,LoE SPEC SEL TINT 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.36 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.36 SHGC 0.36 Simple Glazing,,,,, -U 0.36 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.36 SHGC 0.38 Simple Glazing,,,,, -U 0.38 SHGC 0.26 Dbl Ref B-H Tint 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,REF B TINT HI 6MM,ARGON 13MM,CLEAR 6MM,,, -U 0.38 SHGC 0.30 Dbl Ref-B-H Clr 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,ARGON 13MM,CLEAR 6MM,,, -U 0.39 SHGC 0.32,ExteriorWindow,Metal framing (all other),,,Theoretical Glass 347,,,,, -U 0.39 SHGC 0.38,ExteriorWindow,Metal framing (all other),,,Theoretical Glass 297,,,,, -U 0.40 SHGC 0.43 Dbl LoE Spec Sel Clr 3mm/6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,LoE SPEC SEL CLEAR 3MM,AIR 6MM,CLEAR 6MM,,, -U 0.40 SHGC 0.45,ExteriorWindow,Metal framing (all other),,,ECABS-2 BLEACHED 6MM,AIR 6MM,LoE SPEC SEL CLEAR 6MM Rev,,, -U 0.42 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.42 SHGC 0.25 Simple Glazing,,,,, -U 0.42 SHGC 0.34 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.42 SHGC 0.34 Simple Glazing,,,,, -U 0.42 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,LoE TINT 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.42 SHGC 0.40 Dbl LoE (e2-.1) Tint 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,LoE TINT 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.42 SHGC 0.45 Dbl Ref-D Clr 6mm/13mm Arg,ExteriorWindow,Metal framing (all other),,,REF D CLEAR 6MM,ARGON 13MM,CLEAR 6MM,,, -U 0.43 SHGC 0.26 Dbl Ref-B-H Clr 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,AIR 13MM,CLEAR 6MM,,, -U 0.43 SHGC 0.29 Dbl LoE Spec Sel Tint 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,LoE SPEC SEL TINT 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.44 SHGC 0.20 Dbl Ref-B-H Tint 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,REF B TINT HI 6MM,AIR 13MM,CLEAR 6MM,,, -U 0.44 SHGC 0.26 Dbl Ref-B-H Clr 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,AIR 13MM,CLEAR 6MM,,, -U 0.45 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.45 SHGC 0.25 Simple Glazing,,,,, -U 0.45 SHGC 0.31 Dbl Ref-B-H Clr 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,AIR 13MM,CLEAR 6MM,,, -U 0.45 SHGC 0.33 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.45 SHGC 0.33 Simple Glazing,,,,, -U 0.46 SHGC 0.45 Dbl Grey 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,GREY 6MM,AIR 13MM,CLEAR 6MM,,, -U 0.47 SHGC 0.33 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.47 SHGC 0.33 Simple Glazing,,,,, -U 0.48 SHGC 0.19 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.48 SHGC 0.19 Simple Glazing,,,,, -U 0.48 SHGC 0.21 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.48 SHGC 0.21 Simple Glazing,,,,, -U 0.48 SHGC 0.20 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.48 SHGC 0.20 Simple Glazing,,,,, -U 0.48 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.48 SHGC 0.22 Simple Glazing,,,,, -U 0.48 SHGC 0.40 Dbl Ref-D Clr 6mm/13mm,ExteriorWindow,Metal framing (all other),,,REF D CLEAR 6MM,AIR 13MM,CLEAR 6MM,,, -U 0.50 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.50 SHGC 0.22 Simple Glazing,,,,, -U 0.50 SHGC 0.23 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.50 SHGC 0.23 Simple Glazing,,,,, -U 0.52 SHGC 0.22 Dbl Ref-B-L Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF B CLEAR LO 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.52 SHGC 0.39 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.52 SHGC 0.39 Simple Glazing,,,,, -U 0.52 SHGC 0.40 Dbl Ref-D Clr 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,REF D CLEAR 6MM,AIR 13MM,CLEAR 6MM,,, -U 0.52 SHGC 0.49 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.52 SHGC 0.49 Simple Glazing,,,,, -U 0.52 SHGC 0.615 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.52 SHGC 0.615 Simple Glazing,,,,, -U 0.54 SHGC 0.13 Dbl Ref-A-L Clr 6mm/13mm Air,ExteriorWindow,Metal framing (all other),,,REF A CLEAR LO 6MM,AIR 13MM,CLEAR 6MM,,, -U 0.54 SHGC 0.18 Dbl Ref-A-M Tint 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF A TINT MID 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.54 SHGC 0.23 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.54 SHGC 0.23 Simple Glazing,,,,, -U 0.54 SHGC 0.27 Dbl Ref-C-H Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF C CLEAR HI 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.55 SHGC 0.25,ExteriorWindow,Metal framing (all other),,,Glass_2175_LayerAvg,Gap_1_W_0_0032,Glass_2022F_LayerAvg,,, -U 0.55 SHGC 0.31 Dbl Ref-D Tint 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF D TINT 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.56 SHGC 0.35 Dbl Ref-D Tint 6mm/6mm,ExteriorWindow,Metal framing (all other),,,REF D TINT 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.56 SHGC 0.76 Dbl Clr 3mm/6mm Air,ExteriorWindow,Metal framing (all other),,,CLEAR 3MM,AIR 6MM,CLEAR 3MM,,, -U 0.57 SHGC 0.25 Dbl Ref-C-H Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF C CLEAR HI 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF D CLEAR 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,BLUE 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.59 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.59 SHGC 0.36 Simple Glazing,,,,, -U 0.59 SHGC 0.39 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.59 SHGC 0.39 Simple Glazing,,,,, -U 0.60 SHGC 0.23 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.60 SHGC 0.23 Simple Glazing,,,,, -U 0.62 SHGC 0.20 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.62 SHGC 0.20 Simple Glazing,,,,, -U 0.62 SHGC 0.21 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.62 SHGC 0.21 Simple Glazing,,,,, -U 0.62 SHGC 0.25 Dbl Ref-C-H Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF C CLEAR HI 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.62 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF D CLEAR 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.62 SHGC 0.41 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.62 SHGC 0.41 Simple Glazing,,,,, -U 0.62 SHGC 0.49 Dbl Blue 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,BLUE 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.65 SHGC 0.25 Dbl Ref-C-H Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF C CLEAR HI 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.67 SHGC 0.77 Sgl LoE (e2-.2) Clr 3mm,ExteriorWindow,Metal framing (all other),,,PYR B CLEAR 3MM,,,,, -U 0.71 SHGC 0.25 Dbl Ref-C-H Clr 6mm/6mm Air,ExteriorWindow,Metal framing (all other),,,REF C CLEAR HI 6MM,AIR 6MM,CLEAR 6MM,,, -U 0.72 SHGC 0.25 Sgl Ref-B-M Tint 6mm,ExteriorWindow,Metal framing (all other),,,REF B TINT MID 6MM,,,,, -U 0.72 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.72 SHGC 0.25 Simple Glazing,,,,, -U 0.72 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.72 SHGC 0.36 Simple Glazing,,,,, -U 0.72 SHGC 0.39 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 0.72 SHGC 0.39 Simple Glazing,,,,, -U 0.75 SHGC 0.72 Sgl LoE (e2-.2) Clr 6mm,ExteriorWindow,Metal framing (all other),,,PYR B CLEAR 6MM,,,,, -U 0.88 SHGC 0.16 Sgl Ref-A-L Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF A CLEAR LO 6MM,,,,, -U 0.88 SHGC 0.27 Sgl Elec Ref Colored 6mm,ExteriorWindow,Metal framing (all other),,,ECREF-1 COLORED 6MM,,,,, -U 0.98 SHGC 0.45 Sgl Ref-B-H Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,,,,, -U 0.98 SHGC 0.68 Sgl Ref-B-H Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,,,,, -U 1.17 SHGC 0.39 Sgl Ref-B-H Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,,,,, -U 1.17 SHGC 0.49 Sgl Ref-D Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF D CLEAR 6MM,,,,, -U 1.17 SHGC 0.68 Sgl Green 3mm,ExteriorWindow,Metal framing (all other),,,GREEN 3MM,,,,, -U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm,ExteriorWindow,Metal framing (all other),,,ECREF-1 COLORED 6MM,,,,, -U 1.22 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 1.22 SHGC 0.25 Simple Glazing,,,,, -U 1.22 SHGC 0.34 Sgl Ref-C-H Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF C CLEAR HI 6MM,,,,, -U 1.22 SHGC 0.39 Sgl Ref-B-H Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,,,,, -U 1.22 SHGC 0.54 Simple Glazing Window,ExteriorWindow,Metal framing (all other),,,U 1.22 SHGC 0.54 Simple Glazing,,,,, -U 1.22 SHGC 0.61 Sgl Green 6mm,ExteriorWindow,Metal framing (all other),,,GREEN 6MM,,,,, -U 1.98 SHGC 0.36 Sgl Ref-B-H Clr 6mm,ExteriorWindow,Metal framing (all other),,,REF B CLEAR HI 6MM,,,,, -U 1.98 SHGC 0.61 Sgl Green 6mm,ExteriorWindow,Metal framing (all other),,,GREEN 6MM,,,,, -U0.47_SHGC_0.49_SimpleGlazing_Window_05,ExteriorWindow,,,,U0.47_SHGC_0.49_SimpleGlazing_Window_05,,,,, -U0.47_SHGC0.46_SimpleGlazing_Window_07,ExteriorWindow,,,,U0.47_SHGC0.46_SimpleGlazing_Window_07,,,,, -U0.47_SHGC0.47_SimpleGlazing_Window_06,ExteriorWindow,,,,U0.47_SHGC0.47_SimpleGlazing_Window_06,,,,, -U0.47_SHGC0.47_SimpleGlazing_Window_11,ExteriorWindow,,,,U0.47_SHGC0.47_SimpleGlazing_Window_11,,,,, -U0.47_SHGC0.5_SimpleGlazing_Window_03,ExteriorWindow,,,,U0.47_SHGC0.5_SimpleGlazing_Window_03,,,,, -U0.77_SHGC_0.77_SimpleGlazing_Window_02,ExteriorWindow,,,,U0.77_SHGC_0.77_SimpleGlazing_Window_02,,,,, -U0.77_SHGC0.5_SimpleGlazing_Window_09,ExteriorWindow,,,,U0.77_SHGC0.5_SimpleGlazing_Window_09,,,,, -U0.77_SHGC0.61_SimpleGlazing_Window_08,ExteriorWindow,,,,U0.77_SHGC0.61_SimpleGlazing_Window_08,,,,, -U0.77_SHGC0.62_SimpleGlazing_Window_04,ExteriorWindow,,,,U0.77_SHGC0.62_SimpleGlazing_Window_04,,,,, -U1.23_SHGC0.5_SimpleGlazing_Window_12,ExteriorWindow,,,,U1.23_SHGC0.5_SimpleGlazing_Window_12,,,,, -U1.23_SHGC0.82_SimpleGlazing_Window_01,ExteriorWindow,,,,U1.23_SHGC0.82_SimpleGlazing_Window_01,,,,, -U1.23_SHGC0.82_SimpleGlazing_Window_10,ExteriorWindow,,,,U1.23_SHGC0.82_SimpleGlazing_Window_10,,,,, -Adiabatic GroundContactFloor,GroundContactFloor,Mass,,,Adiabatic Material,,,,, -ext-slab,GroundContactFloor,Mass,,,6 in. Normalweight Concrete Floor,,,,, -ext-slab-mass,GroundContactFloor,Mass,CP02 CARPET PAD,,HW CONCRETE,CP02 CARPET PAD,,,, -ext-slab-metal-building,GroundContactFloor,Metal Building,,,HW CONCRETE 8 in,,,,, -ext-slab-steel-frame,GroundContactFloor,SteelFramed,CP02 CARPET PAD,,HW CONCRETE 8 in,CP02 CARPET PAD,,,, -Ground FloorGround_Floor_R11_T2013,GroundContactFloor,,,,Ground_Floor_R11_T2013,Plywood - 5/8 in. CBES,Carpet - 3/4 in. CBES,,, -Ground FloorGround_Floor_R17_T2013,GroundContactFloor,,,,Ground_Floor_R17_T2013,Plywood - 5/8 in. CBES,Carpet - 3/4 in. CBES,,, -Ground FloorGround_Floor_R22_T2013,GroundContactFloor,,,,Ground_Floor_R22_T2013,Plywood - 5/8 in. CBES,Carpet - 3/4 in. CBES,,, -Smallhotel 2010 Slab Floor,GroundContactFloor,Mass,Typical Insulation,,8 in. Normalweight Concrete Floor,CP02 CARPET PAD,,,, -Typical Carpeted 6in Slab Floor,GroundContactFloor,Mass,,,6 in. Normalweight Concrete Floor,Typical Carpet Pad,,,, -Typical Carpeted 8in Slab Floor,GroundContactFloor,Mass,,,8 in. Normalweight Concrete Floor,Typical Carpet Pad,,,, -Typical Insulated 6in Slab Floor,GroundContactFloor,Mass,Typical Insulation,,Typical Insulation,6 in. Normalweight Concrete Floor,,,, -Typical Insulated 8in Slab Floor,GroundContactFloor,Mass,Typical Insulation,,Typical Insulation,8 in. Normalweight Concrete Floor,,,, -Typical Insulated Carpeted 6in Slab Floor,GroundContactFloor,Mass,Typical Insulation,,Typical Insulation,6 in. Normalweight Concrete Floor,Typical Carpet Pad,,, -Typical Insulated Carpeted 8in Slab Floor,GroundContactFloor,Mass,Typical Insulation,,Typical Insulation,8 in. Normalweight Concrete Floor,Typical Carpet Pad,,, -Typical Uncarpeted 6in Slab Floor,GroundContactFloor,Mass,,,6 in. Normalweight Concrete Floor,,,,, -Typical Uninsulated 6in Slab Floor,GroundContactFloor,Mass,,,6 in. Normalweight Concrete Floor,,,,, -Typical Uninsulated 8in Slab Floor,GroundContactFloor,Mass,,,8 in. Normalweight Concrete Floor,,,,, -Typical Uninsulated Carpeted 8in Slab Floor,GroundContactFloor,Mass,,,8 in. Concrete Block Basement Wall,Typical Carpet Pad,,,, -Typical Unisulated Carpeted 6in Slab Floor,GroundContactFloor,Mass,,,6 in. Normalweight Concrete Floor,Typical Carpet Pad,,,, -Typical Insulated Basement Mass Wall,GroundContactWall,Mass,Typical Insulation,,Typical Insulation,8 in. Concrete Block Basement Wall,,,, -Typical Uninsulated Basement Mass Wall,GroundContactWall,Mass,,,8 in. Concrete Block Basement Wall,,,,, -ceiling_Metal roof,InteriorCeiling,,,,Metal Standing Seam - 1/16 in.,ceiling_2_Insulation,,,, -int_slab_ceiling_smallhotel,InteriorCeiling,,,,CP02 CARPET PAD,4 in. Normalweight Concrete Floor,,,, -LargeHotel Interior Ceiling,InteriorCeiling,,,,CP02 CARPET PAD,100mm Normalweight concrete floor,Nonres_Floor_Insulation,G01 13mm gypsum board,, -NACM_Drop Ceiling,InteriorCeiling,,,,Acoustic Ceiling,,,,, -Plenum Acoustical Tile,InteriorCeiling,,,,Acoustic Tile - 1/2 in.,,,,, -Typical Interior Ceiling,InteriorCeiling,,,,CP02 CARPET PAD,100mm Normalweight concrete floor,,,, -Typical Interior Door,InteriorDoor,,,,G05 25mm wood,,,,, -int_slab_floor_smallhotel,InteriorFloor,,,,4 in. Normalweight Concrete Floor,CP02 CARPET PAD,,,, -LargeHotel Interior Floor,InteriorFloor,,,,G01 13mm gypsum board,Nonres_Floor_Insulation,100mm Normalweight concrete floor,CP02 CARPET PAD,, -NACM_Interior Floor,InteriorFloor,,,,NACM_Carpet 3/4in,,,,, -Typical Interior Floor,InteriorFloor,,,,100mm Normalweight concrete floor,CP02 CARPET PAD,,,, -Typical Interior Slab Floor,InteriorFloor,Mass,,,4 in. Normalweight Concrete Floor,Typical Carpet Pad,,,, -Typical Interior Partition,InteriorPartition,,,,G05 25mm wood,,,,, -Uninsulated Steel Stud Wall,InteriorPartition,SteelFramed,,,Metal Framed Wall - 24inOC - 2x4 - R0 ins.,,,,, -int_wall_smallhotel,InteriorWall,,,,1/2 in. Gypsum Board,1/2 in. Gypsum Board,,,, -LargeHotel Interior Wall,InteriorWall,,,,G01 13mm gypsum board,G01 13mm gypsum board,,,, -NACM_Interior Wall,InteriorWall,,,,NACM_Gypsum Board 5/8in,NACM_Gypsum Board 5/8in,,,, -Typical Insulated Interior Wall,InteriorWall,WoodFramed,Typical Insulation,,25mm Stucco,5/8 in. Gypsum Board,Typical Insulation,Steel Frame/Cavity,5/8 in. Gypsum Board, -Typical Interior Wall,InteriorWall,,,,G01 13mm gypsum board,G01 13mm gypsum board,,,, -Typical Uninsulated Interior Wall,InteriorWall,WoodFramed,,,1/2 in. Gypsum Board,1/2 in. Gypsum Board,,,, -Typical Interior Window,InteriorWindow,,,,CLEAR 3MM,,,,, -U 0.58 SHGC 0.19 Simple Glazing Skylight,Skylight,Glass with Curb,,,U 0.58 SHGC 0.19 Simple Glazing,,,,, -U 0.58 SHGC 0.36 Simple Glazing Skylight,Skylight,Glass with Curb,,,U 0.58 SHGC 0.36 Simple Glazing,,,,, -U 1.98 SHGC 0.61 Simple Glazing Skylight,Skylight,Glass with Curb,,,U 1.98 SHGC 0.61 Simple Glazing,,,,, -Window_U_0.50_SHGC_0.40_Skylight_Frame_Width_0.000_in,Skylight,,,Skylight_Frame_Width_0.000_in,Glass_2052_LayerAvg,Gap_1_W_0_0038,Glass_2027F_LayerAvg,,, -Window_U_0.50_SHGC_0.40_Skylight_Frame_Width_0.334_in,Skylight,,,Skylight_Frame_Width_0.334_in,Glass_2052_LayerAvg,Gap_1_W_0_0038,Glass_2027F_LayerAvg,,, -Window_U_0.50_SHGC_0.40_Skylight_Frame_Width_0.430_in,Skylight,,,Skylight_Frame_Width_0.430_in,Glass_2052_LayerAvg,Gap_1_W_0_0038,Glass_2027F_LayerAvg,,, -Window_U_0.55_SHGC_0.35_Skylight_Frame_Width_0.709_in,Skylight,,,Skylight_Frame_Width_0.709_in,Glass_2052_LayerAvg,Gap_1_W_0_0038,Glass_2027F_LayerAvg,,, -Window_U_0.65_SHGC_0.35_Skylight_Frame_Width_2.339_in,Skylight,,,Skylight_Frame_Width_2.339_in,Glass_2052_LayerAvg,Gap_1_W_0_0024,Glass_2027F_LayerAvg,,, -Window_U_0.75_SHGC_0.35_Skylight_Frame_Width_2.339_in,Skylight,,,Skylight_Frame_Width_2.339_in,Glass_2052_LayerAvg,Gap_1_W_0_0018,Glass_2027F_LayerAvg,,, -U 0.60 SHGC 0.25 Dbl 2.5mm air,,,,,Glass_2175_LayerAvg,Gap_1_W_0_0025,Glass_2022F_LayerAvg,,, -U 0.61 SHGC 0.77 Simple Glazing Skylight,,,,,U 0.61 SHGC 0.77 Simple Glazing,,,,, -U 0.65 SHGC 0.35 Simple Glazing Skylight,,,,,U 0.65 SHGC 0.35 Simple Glazing,,,,, -U 0.69 SHGC 0.19 Simple Glazing Skylight,,,,,U 0.69 SHGC 0.19 Simple Glazing,,,,, -U 0.69 SHGC 0.36 Simple Glazing Skylight,,,,,U 0.69 SHGC 0.36 Simple Glazing,,,,, -U 0.69 SHGC 0.39 Simple Glazing Skylight,,,,,U 0.69 SHGC 0.39 Simple Glazing,,,,, -U 0.69 SHGC 0.49 Simple Glazing Skylight,,,,,U 0.69 SHGC 0.49 Simple Glazing,,,,, -U 0.69 SHGC 0.64 Simple Glazing Skylight,,,,,U 0.69 SHGC 0.64 Simple Glazing,,,,, -U 0.69 SHGC 0.68 Simple Glazing Skylight,,,,,U 0.69 SHGC 0.68 Simple Glazing,,,,, -U 0.74 SHGC 0.55 Simple Glazing Skylight,,,,,U 0.74 SHGC 0.55 Simple Glazing,,,,, -U 0.74 SHGC 0.65 Simple Glazing Skylight,,,,,U 0.74 SHGC 0.65 Simple Glazing,,,,, -U 0.75 SHGC 0.35 Simple Glazing Skylight,,,,,U 0.75 SHGC 0.35 Simple Glazing,,,,, -U 0.81 SHGC 0.65 Simple Glazing Skylight,,,,,U 0.81 SHGC 0.65 Simple Glazing,,,,, -U 0.85 SHGC 0.65 Simple Glazing Skylight,,,,,U 0.85 SHGC 0.65 Simple Glazing,,,,, -U 0.87 SHGC 0.58 Simple Glazing Skylight,,,,,U 0.87 SHGC 0.58 Simple Glazing,,,,, -U 0.87 SHGC 0.71 Simple Glazing Skylight,,,,,U 0.87 SHGC 0.71 Simple Glazing,,,,, -U 0.87 SHGC 0.77 Simple Glazing Skylight,,,,,U 0.87 SHGC 0.77 Simple Glazing,,,,, -U 0.98 SHGC 0.19 Simple Glazing Skylight,,,,,U 0.98 SHGC 0.19 Simple Glazing,,,,, -U 0.98 SHGC 0.36 Simple Glazing Skylight,,,,,U 0.98 SHGC 0.36 Simple Glazing,,,,, -U 1.10 SHGC 0.62 Simple Glazing Skylight,,,,,U 1.10 SHGC 0.62 Simple Glazing,,,,, -U 1.10 SHGC 0.77 Simple Glazing Skylight,,,,,U 1.10 SHGC 0.77 Simple Glazing,,,,, -U 1.15 SHGC 0.77 Simple Glazing Skylight,,,,,U 1.15 SHGC 0.77 Simple Glazing,,,,, -U 1.17 SHGC 0.19 Simple Glazing Skylight,,,,,U 1.17 SHGC 0.19 Simple Glazing,,,,, -U 1.17 SHGC 0.36 Simple Glazing Skylight,,,,,U 1.17 SHGC 0.36 Simple Glazing,,,,, -U 1.17 SHGC 0.39 Simple Glazing Skylight,,,,,U 1.17 SHGC 0.39 Simple Glazing,,,,, -U 1.17 SHGC 0.49 Simple Glazing Skylight,,,,,U 1.17 SHGC 0.49 Simple Glazing,,,,, -U 1.17 SHGC 0.64 Simple Glazing Skylight,,,,,U 1.17 SHGC 0.64 Simple Glazing,,,,, -U 1.17 SHGC 0.68 Simple Glazing Skylight,,,,,U 1.17 SHGC 0.68 Simple Glazing,,,,, -U 1.30 SHGC 0.27 Simple Glazing Skylight,,,,,U 1.30 SHGC 0.27 Simple Glazing,,,,, -U 1.30 SHGC 0.34 Simple Glazing Skylight,,,,,U 1.30 SHGC 0.34 Simple Glazing,,,,, -U 1.30 SHGC 0.62 Simple Glazing Skylight,,,,,U 1.30 SHGC 0.62 Simple Glazing,,,,, -U 1.30 SHGC 0.65 Simple Glazing Skylight,,,,,U 1.30 SHGC 0.65 Simple Glazing,,,,, -U 1.36 SHGC 0.19 Simple Glazing Skylight,,,,,U 1.36 SHGC 0.19 Simple Glazing,,,,, -U 1.36 SHGC 0.36 Simple Glazing Skylight,,,,,U 1.36 SHGC 0.36 Simple Glazing,,,,, -U 1.36 SHGC 0.39 Simple Glazing Skylight,,,,,U 1.36 SHGC 0.39 Simple Glazing,,,,, -U 1.36 SHGC 0.61 Simple Glazing Skylight,,,,,U 1.36 SHGC 0.61 Simple Glazing,,,,, -U 1.70 SHGC 0.36 Simple Glazing Skylight,,,,,U 1.70 SHGC 0.36 Simple Glazing,,,,, -U 1.80 SHGC 0.36 Simple Glazing Skylight,,,,,U 1.80 SHGC 0.36 Simple Glazing,,,,, -U 1.90 SHGC 0.27 Simple Glazing Skylight,,,,,U 1.90 SHGC 0.27 Simple Glazing,,,,, -U 1.90 SHGC 0.34 Simple Glazing Skylight,,,,,U 1.90 SHGC 0.34 Simple Glazing,,,,, -U 1.90 SHGC 0.39 Simple Glazing Skylight,,,,,U 1.90 SHGC 0.39 Simple Glazing,,,,, -U 1.90 SHGC 0.65 Simple Glazing Skylight,,,,,U 1.90 SHGC 0.65 Simple Glazing,,,,, -U 1.98 SHGC 0.16 Simple Glazing Skylight,,,,,U 1.98 SHGC 0.16 Simple Glazing,,,,, -U 1.98 SHGC 0.19 Simple Glazing Skylight,,,,,U 1.98 SHGC 0.19 Simple Glazing,,,,, -U 1.98 SHGC 0.36 Simple Glazing Skylight,,,,,U 1.98 SHGC 0.36 Simple Glazing,,,,, -U 1.98 SHGC 0.39 Simple Glazing Skylight,,,,,U 1.98 SHGC 0.39 Simple Glazing,,,,, -U 0.49 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.49 SHGC 0.22 Simple Glazing,,,,, -U 0.57 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.57 SHGC 0.25 Simple Glazing,,,,, -U 0.53 SHGC 0.25 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.53 SHGC 0.25 Simple Glazing,,,,, -U 0.48 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.48 SHGC 0.25 Simple Glazing,,,,, -U 0.38 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.38 SHGC 0.36 Simple Glazing,,,,, -U 0.38 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.38 SHGC 0.38 Simple Glazing,,,,, -U 0.36 SHGC 0.4 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.36 SHGC 0.4 Simple Glazing,,,,, -U 0.33 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.33 SHGC 0.45 Simple Glazing,,,,, -U 0.29 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.29 SHGC 0.45 Simple Glazing,,,,, -U 0.5 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.5 SHGC 0.22 Simple Glazing,,,,, -U 0.54 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.54 SHGC 0.25 Simple Glazing,,,,, -U 0.49 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.49 SHGC 0.25 Simple Glazing,,,,, -U 0.45 SHGC 0.25 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.45 SHGC 0.25 Simple Glazing,,,,, -U 1.19 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 1.19 SHGC 0.45 Simple Glazing,,,,, -U 0.73 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.73 SHGC 0.45 Simple Glazing,,,,, -U 0.62 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.62 SHGC 0.45 Simple Glazing,,,,, -U 0.51 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.51 SHGC 0.45 Simple Glazing,,,,, -U 0.38 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.38 SHGC 0.45 Simple Glazing,,,,, -U 0.53 SHGC 0.22 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.53 SHGC 0.22 Simple Glazing,,,,, -U 0.53 SHGC 0.23 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.53 SHGC 0.23 Simple Glazing,,,,, -U 0.38 SHGC 0.35 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.38 SHGC 0.35 Simple Glazing,,,,, -U 0.38 SHGC 0.37 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.38 SHGC 0.37 Simple Glazing,,,,, -U 0.36 SHGC 0.37 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.36 SHGC 0.37 Simple Glazing,,,,, -U 0.31 SHGC 0.39 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.31 SHGC 0.39 Simple Glazing,,,,, -U 0.28 SHGC 0.39 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.28 SHGC 0.39 Simple Glazing,,,,, -U 0.51 SHGC 0.22 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.51 SHGC 0.22 Simple Glazing,,,,, -U 0.51 SHGC 0.23 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.51 SHGC 0.23 Simple Glazing,,,,, -U 0.46 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.46 SHGC 0.25 Simple Glazing,,,,, -U 0.43 SHGC 0.25 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.43 SHGC 0.25 Simple Glazing,,,,, -U 0.36 SHGC 0.36 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.36 SHGC 0.36 Simple Glazing,,,,, -U 0.36 SHGC 0.38 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.36 SHGC 0.38 Simple Glazing,,,,, -U 0.34 SHGC 0.38 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.34 SHGC 0.38 Simple Glazing,,,,, -U 0.29 SHGC 0.4 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.29 SHGC 0.4 Simple Glazing,,,,, -U 0.26 SHGC 0.4 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.26 SHGC 0.4 Simple Glazing,,,,, -U 0.37 SHGC 0.36 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.37 SHGC 0.36 Simple Glazing,,,,, -U 0.37 SHGC 0.38 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.37 SHGC 0.38 Simple Glazing,,,,, -U 0.35 SHGC 0.38 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.35 SHGC 0.38 Simple Glazing,,,,, -U 0.3 SHGC 0.4 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.3 SHGC 0.4 Simple Glazing,,,,, -U 0.27 SHGC 0.4 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.27 SHGC 0.4 Simple Glazing,,,,, -U 0.5 SHGC 0.23 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.5 SHGC 0.23 Simple Glazing,,,,, -U 0.42 SHGC 0.25 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.42 SHGC 0.25 Simple Glazing,,,,, -U 0.47 SHGC 0.25 Simple Glazing Window Weighted,ExteriorWindow,Weighted,,,U 0.47 SHGC 0.25 Simple Glazing,,,,, -U 1.2 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 1.2 SHGC 0.45 Simple Glazing,,,,, -U 0.5 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.5 SHGC 0.45 Simple Glazing,,,,, -U 0.39 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.39 SHGC 0.45 Simple Glazing,,,,, -U 0.36 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.36 SHGC 0.45 Simple Glazing,,,,, -U 0.75 SHGC 0.35 Simple Glazing Window,Skylight,Weighted,,,U 0.75 SHGC 0.35 Simple Glazing Window,,,,, -U 0.65 SHGC 0.35 Simple Glazing Window,Skylight,Weighted,,,U 0.65 SHGC 0.35 Simple Glazing Window,,,,, -U 0.55 SHGC 0.35 Simple Glazing Window,Skylight,Weighted,,,U 0.55 SHGC 0.35 Simple Glazing,,,,, -U 0.5 SHGC 0.4 Simple Glazing Window,Skylight,Weighted,,,U 0.5 SHGC 0.4 Simple Glazing,,,,, -U 0.5 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 0.5 SHGC 0.55 Simple Glazing,,,,, -U 0.41 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 0.41 SHGC 0.55 Simple Glazing,,,,, -U 1.8 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 1.8 SHGC 0.55 Simple Glazing,,,,, -U 1.7 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 1.7 SHGC 0.55 Simple Glazing,,,,, -U 1.15 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 1.15 SHGC 0.55 Simple Glazing,,,,, -U 0.98 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 0.98 SHGC 0.55 Simple Glazing,,,,, -U 0.85 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 0.85 SHGC 0.55 Simple Glazing,,,,, -U 0.7 SHGC 0.3 Simple Glazing Window,Skylight,Weighted,,,U 0.7 SHGC 0.3 Simple Glazing,,,,, -U 0.65 SHGC 0.3 Simple Glazing Window,Skylight,Weighted,,,U 0.65 SHGC 0.3 Simple Glazing,,,,, -U 0.55 SHGC 0.3 Simple Glazing Window,Skylight,Weighted,,,U 0.55 SHGC 0.3 Simple Glazing,,,,, -U 0.47 SHGC 0.4 Simple Glazing Window,Skylight,Weighted,,,U 0.47 SHGC 0.4 Simple Glazing,,,,, -U 0.44 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 0.44 SHGC 0.55 Simple Glazing,,,,, -U 0.9 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 0.9 SHGC 0.55 Simple Glazing,,,,, -U 0.75 SHGC 0.55 Simple Glazing Window,Skylight,Weighted,,,U 0.75 SHGC 0.55 Simple Glazing,,,,, -U 0.37 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.37 SHGC 0.25 Simple Glazing,,,,, -U 0.83 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.83 SHGC 0.25 Simple Glazing,,,,, -U 0.77 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.77 SHGC 0.25 Simple Glazing,,,,, -U 0.93 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.93 SHGC 0.45 Simple Glazing,,,,, -U 0.83 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.83 SHGC 0.45 Simple Glazing,,,,, -U 0.65 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 0.65 SHGC 0.55 Simple Glazing,,,,, -U 1.8 SHGC 0.77 Simple Glazing Skylight,Skylight,Weighted,,,U 1.8 SHGC 0.77 Simple Glazing,,,,, -U 0.65 SHGC 0.77 Simple Glazing Skylight,Skylight,Weighted,,,U 0.65 SHGC 0.77 Simple Glazing,,,,, -U 1.8 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 1.8 SHGC 0.55 Simple Glazing,,,,, -U 0.65 SHGC 0.68 Simple Glazing Skylight,Skylight,Weighted,,,U 0.65 SHGC 0.68 Simple Glazing,,,,, -U 1.8 SHGC 0.64 Simple Glazing Skylight,Skylight,Weighted,,,U 1.8 SHGC 0.64 Simple Glazing,,,,, -U 0.33 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.33 SHGC 0.25 Simple Glazing,,,,, -U 0.68 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.68 SHGC 0.25 Simple Glazing,,,,, -U 0.87 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.87 SHGC 0.45 Simple Glazing,,,,, -U 0.77 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.77 SHGC 0.45 Simple Glazing,,,,, -U 0.55 SHGC 0.64 Simple Glazing Skylight,Skylight,Weighted,,,U 0.55 SHGC 0.64 Simple Glazing,,,,, -U 0.55 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 0.55 SHGC 0.55 Simple Glazing,,,,, -U 1.7 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 1.7 SHGC 0.55 Simple Glazing,,,,, -U 0.31 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.31 SHGC 0.36 Simple Glazing,,,,, -U 0.68 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.68 SHGC 0.36 Simple Glazing,,,,, -U 0.5 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 0.5 SHGC 0.55 Simple Glazing,,,,, -U 1.15 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 1.15 SHGC 0.55 Simple Glazing,,,,, -U 0.31 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.31 SHGC 0.38 Simple Glazing,,,,, -U 0.68 SHGC 0.38 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.68 SHGC 0.38 Simple Glazing,,,,, -U 0.45 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.45 SHGC 0.45 Simple Glazing,,,,, -U 0.5 SHGC 0.36 Simple Glazing Skylight,Skylight,Weighted,,,U 0.5 SHGC 0.36 Simple Glazing,,,,, -U 0.5 SHGC 0.19 Simple Glazing Skylight,Skylight,Weighted,,,U 0.5 SHGC 0.19 Simple Glazing,,,,, -U 0.98 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 0.98 SHGC 0.55 Simple Glazing,,,,, -U 0.5 SHGC 0.34 Simple Glazing Skylight,Skylight,Weighted,,,U 0.5 SHGC 0.34 Simple Glazing,,,,, -U 0.98 SHGC 0.27 Simple Glazing Skylight,Skylight,Weighted,,,U 0.98 SHGC 0.27 Simple Glazing,,,,, -U 0.68 SHGC 0.4 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.68 SHGC 0.4 Simple Glazing,,,,, -U 0.85 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 0.85 SHGC 0.55 Simple Glazing,,,,, -U 0.85 SHGC 0.19 Simple Glazing Skylight,Skylight,Weighted,,,U 0.85 SHGC 0.19 Simple Glazing,,,,, -U 0.85 SHGC 0.39 Simple Glazing Skylight,Skylight,Weighted,,,U 0.85 SHGC 0.39 Simple Glazing,,,,, -U 0.28 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.28 SHGC 0.45 Simple Glazing,,,,, -U 0.68 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.68 SHGC 0.45 Simple Glazing,,,,, -U 0.32 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.32 SHGC 0.45 Simple Glazing,,,,, -U 0.5 SHGC 0.27 Simple Glazing Skylight,Skylight,Weighted,,,U 0.5 SHGC 0.27 Simple Glazing,,,,, -U 0.25 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.25 SHGC 0.45 Simple Glazing,,,,, -U 0.5 SHGC 0.39 Simple Glazing Skylight,Skylight,Weighted,,,U 0.5 SHGC 0.39 Simple Glazing,,,,, -U 0.5 SHGC 0.65 Simple Glazing Skylight,Skylight,Weighted,,,U 0.5 SHGC 0.65 Simple Glazing,,,,, -U 0.85 SHGC 0.27 Simple Glazing Skylight,Skylight,Weighted,,,U 0.85 SHGC 0.27 Simple Glazing,,,,, -U 0.5 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.5 SHGC 0.25 Simple Glazing,,,,, -U 1.1 SHGC 0.25 Simple Glazing Window,ExteriorWindow,Weighted,,,U 1.1 SHGC 0.25 Simple Glazing,,,,, -U 1.1 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 1.1 SHGC 0.45 Simple Glazing,,,,, -U 0.75 SHGC 0.55 Simple Glazing Skylight,Skylight,Weighted,,,U 0.75 SHGC 0.55 Simple Glazing,,,,, -U 0.75 SHGC 0.49 Simple Glazing Skylight,Skylight,Weighted,,,U 0.75 SHGC 0.49 Simple Glazing,,,,, -U 1.8 SHGC 0.49 Simple Glazing Skylight,Skylight,Weighted,,,U 1.8 SHGC 0.49 Simple Glazing,,,,, -U 0.75 SHGC 0.39 Simple Glazing Skylight,Skylight,Weighted,,,U 0.75 SHGC 0.39 Simple Glazing,,,,, -U 0.75 SHGC 0.68 Simple Glazing Skylight,Skylight,Weighted,,,U 0.75 SHGC 0.68 Simple Glazing,,,,, -U 0.75 SHGC 0.64 Simple Glazing Skylight,Skylight,Weighted,,,U 0.75 SHGC 0.64 Simple Glazing,,,,, -U 0.77 SHGC 0.23 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.77 SHGC 0.23 Simple Glazing,,,,, -U 0.68 SHGC 0.23 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.68 SHGC 0.23 Simple Glazing,,,,, -U 0.63 SHGC 0.33 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.63 SHGC 0.33 Simple Glazing,,,,, -U 0.63 SHGC 0.34 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.63 SHGC 0.34 Simple Glazing,,,,, -U 0.63 SHGC 0.36 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.63 SHGC 0.36 Simple Glazing,,,,, -U 0.63 SHGC 0.45 Simple Glazing Window,ExteriorWindow,Weighted,,,U 0.63 SHGC 0.45 Simple Glazing,,,,, -U 0.55 SHGC 0.35 Simple Glazing Skylight,Skylight,,,,U 0.55 SHGC 0.35 Simple Glazing,,,,, -U 0.5 SHGC 0.4 Simple Glazing Skylight,Skylight,,,,U 0.5 SHGC 0.4 Simple Glazing,,,,, -U 0.41 SHGC 0.55 Simple Glazing Skylight,Skylight,,,,U 0.41 SHGC 0.55 Simple Glazing,,,,, -U 0.6 SHGC 0.23 Simple Glazing Window,ExteriorWindow,,,,U 0.6 SHGC 0.23 Simple Glazing,,,,, -U 0.65 SHGC 0.3 Simple Glazing Skylight,Skylight,,,,U 0.65 SHGC 0.3 Simple Glazing,,,,, -U 0.55 SHGC 0.3 Simple Glazing Skylight,Skylight,,,,U 0.55 SHGC 0.3 Simple Glazing,,,,, -U 0.47 SHGC 0.4 Simple Glazing Skylight,Skylight,,,,U 0.47 SHGC 0.4 Simple Glazing,,,,, -U 0.44 SHGC 0.55 Simple Glazing Skylight,Skylight,,,,U 0.44 SHGC 0.55 Simple Glazing,,,,, -U 0.83 SHGC 0.21 Simple Glazing Window,ExteriorWindow,,,,U 0.83 SHGC 0.21 Simple Glazing,,,,, -U 0.7 SHGC 0.3 Simple Glazing Skylight,Skylight,,,,U 0.7 SHGC 0.3 Simple Glazing,,,,, -U 0.32 SHGC 0.22 Simple Glazing Window,ExteriorWindow,,,,U 0.32 SHGC 0.22 Simple Glazing,,,,, -U 0.83 SHGC 0.22 Simple Glazing Window,ExteriorWindow,,,,U 0.83 SHGC 0.22 Simple Glazing,,,,, -U 0.83 SHGC 0.2 Simple Glazing Window,ExteriorWindow,,,,U 0.83 SHGC 0.2 Simple Glazing,,,,, -U 0.62 SHGC 0.2 Simple Glazing Window,ExteriorWindow,,,,U 0.62 SHGC 0.2 Simple Glazing,,,,, -U 1.22 SHGC 0.19 Simple Glazing Window,ExteriorWindow,,,,U 1.22 SHGC 0.19 Simple Glazing,,,,, -U 1.22 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 1.22 SHGC 0.45 Simple Glazing,,,,, -U 1.22 SHGC 0.17 Simple Glazing Window,ExteriorWindow,,,,U 1.22 SHGC 0.17 Simple Glazing,,,,, -U 1.22 SHGC 0.39 Simple Glazing Window,ExteriorWindow,,,,U 1.22 SHGC 0.39 Simple Glazing,,,,, -U 0.98 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.98 SHGC 0.45 Simple Glazing,,,,, -U 1.98 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 1.98 SHGC 0.45 Simple Glazing,,,,, -U 0.57 SHGC 0.39 Simple Glazing Window,ExteriorWindow,,,,U 0.57 SHGC 0.39 Simple Glazing,,,,, -U 0.46 SHGC 0.19 Simple Glazing Window,ExteriorWindow,,,,U 0.46 SHGC 0.19 Simple Glazing,,,,, -U 1.98 SHGC 0.34 Simple Glazing Skylight,Skylight,,,,U 1.98 SHGC 0.34 Simple Glazing,,,,, -U 1.22 SHGC 0.61 Simple Glazing Window,ExteriorWindow,,,,U 1.22 SHGC 0.61 Simple Glazing,,,,, -U 1.22 SHGC 0.34 Simple Glazing Window,ExteriorWindow,,,,U 1.22 SHGC 0.34 Simple Glazing,,,,, -U 0.57 SHGC 0.49 Simple Glazing Window,ExteriorWindow,,,,U 0.57 SHGC 0.49 Simple Glazing,,,,, -U 0.46 SHGC 0.26 Simple Glazing Window,ExteriorWindow,,,,U 0.46 SHGC 0.26 Simple Glazing,,,,, -U 0.98 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 0.98 SHGC 0.45 Simple Glazing,,,,, -U 1.98 SHGC 0.65 Simple Glazing Skylight,Skylight,,,,U 1.98 SHGC 0.65 Simple Glazing,,,,, -U 0.58 SHGC 0.61 Simple Glazing Skylight,Skylight,,,,U 0.58 SHGC 0.61 Simple Glazing,,,,, -U 0.46 SHGC 0.36 Simple Glazing Window,ExteriorWindow,,,,U 0.46 SHGC 0.36 Simple Glazing,,,,, -U 0.46 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.46 SHGC 0.45 Simple Glazing,,,,, -U 0.35 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.35 SHGC 0.45 Simple Glazing,,,,, -U 0.98 SHGC 0.62 Simple Glazing Skylight,Skylight,,,,U 0.98 SHGC 0.62 Simple Glazing,,,,, -U 0.58 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 0.58 SHGC 0.45 Simple Glazing,,,,, -U 0.75 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.75 SHGC 0.25 Simple Glazing,,,,, -U 0.7 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.7 SHGC 0.25 Simple Glazing,,,,, -U 1.98 SHGC 0.49 Simple Glazing Skylight,Skylight,,,,U 1.98 SHGC 0.49 Simple Glazing,,,,, -U 0.65 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.65 SHGC 0.25 Simple Glazing,,,,, -U 0.6 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.6 SHGC 0.25 Simple Glazing,,,,, -U 0.9 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.9 SHGC 0.25 Simple Glazing,,,,, -U 1.98 SHGC 0.71 Simple Glazing Skylight,Skylight,,,,U 1.98 SHGC 0.71 Simple Glazing,,,,, -U 0.4 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.4 SHGC 0.4 Simple Glazing,,,,, -U 0.55 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.55 SHGC 0.4 Simple Glazing,,,,, -U 0.85 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.85 SHGC 0.4 Simple Glazing,,,,, -U 0.35 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.35 SHGC 0.4 Simple Glazing,,,,, -U 0.45 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.45 SHGC 0.4 Simple Glazing,,,,, -U 0.8 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.8 SHGC 0.4 Simple Glazing,,,,, -U 0.65 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.65 SHGC 0.45 Simple Glazing,,,,, -U 0.6 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.6 SHGC 0.45 Simple Glazing,,,,, -U 0.9 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.9 SHGC 0.45 Simple Glazing,,,,, -U 0.4 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.4 SHGC 0.45 Simple Glazing,,,,, -U 0.8 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.8 SHGC 0.45 Simple Glazing,,,,, -U 1.2 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 1.2 SHGC 0.25 Simple Glazing,,,,, -U 1.98 SHGC 0.27 Simple Glazing Skylight,Skylight,,,,U 1.98 SHGC 0.27 Simple Glazing,,,,, -U 1.17 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 1.17 SHGC 0.45 Simple Glazing,,,,, -U 0.98 SHGC 0.49 Simple Glazing Skylight,Skylight,,,,U 0.98 SHGC 0.49 Simple Glazing,,,,, -U 0.98 SHGC 0.46 Simple Glazing Skylight,Skylight,,,,U 0.98 SHGC 0.46 Simple Glazing,,,,, -U 0.58 SHGC 0.65 Simple Glazing Skylight,Skylight,,,,U 0.58 SHGC 0.65 Simple Glazing,,,,, -U 0.58 SHGC 0.55 Simple Glazing Skylight,Skylight,,,,U 0.58 SHGC 0.55 Simple Glazing,,,,, -U 0.4 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.4 SHGC 0.25 Simple Glazing,,,,, -U 0.65 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 0.65 SHGC 0.45 Simple Glazing,,,,, -U 0.35 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.35 SHGC 0.25 Simple Glazing,,,,, -U 0.55 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 0.55 SHGC 0.45 Simple Glazing,,,,, -U 0.42 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.42 SHGC 0.4 Simple Glazing,,,,, -U 0.77 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.77 SHGC 0.4 Simple Glazing,,,,, -U 0.81 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.81 SHGC 0.45 Simple Glazing,,,,, -U 0.5 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 0.5 SHGC 0.45 Simple Glazing,,,,, -U 0.32 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.32 SHGC 0.4 Simple Glazing,,,,, -U 0.7 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.7 SHGC 0.45 Simple Glazing,,,,, -U 0.59 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.59 SHGC 0.45 Simple Glazing,,,,, -U 0.44 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.44 SHGC 0.45 Simple Glazing,,,,, -U 0.93 SHGC 0.25 Simple Glazing Window,ExteriorWindow,,,,U 0.93 SHGC 0.25 Simple Glazing,,,,, -U 0.75 SHGC 0.45 Simple Glazing Skylight,Skylight,,,,U 0.75 SHGC 0.45 Simple Glazing,,,,, -U 0.3 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.3 SHGC 0.4 Simple Glazing,,,,, -U 0.36 SHGC 0.4 Simple Glazing Window,ExteriorWindow,,,,U 0.36 SHGC 0.4 Simple Glazing,,,,, -U 0.9 SHGC 0.55 Simple Glazing Skylight,Skylight,,,,U 0.9 SHGC 0.55 Simple Glazing,,,,, -U 0.48 SHGC 0.45 Simple Glazing Window,ExteriorWindow,,,,U 0.48 SHGC 0.45 Simple Glazing,,,,, diff --git a/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.csv b/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.csv deleted file mode 100644 index 7922e7d82b..0000000000 --- a/data/openstudio_standards_data/database_files/support_electric_equipment_space_type_name_tags.csv +++ /dev/null @@ -1,59 +0,0 @@ -support_electric_equipment_space_type_name_tags -airport_concourse_electric_equipment -atrium_lt_20_ft_height_electric_equipment -attic_electric_equipment -audience_seating_all_other_electric_equipment -baggage_carousel_electric_equipment -banking_activity_electric_equipment -classroom_lecture_training_all_other_electric_equipment -computer_room_electric_equipment -conference_meeting_multipurpose_electric_equipment -confinement_cells_electric_equipment -corridor_all_other_electric_equipment -courtroom_electric_equipment -dining_all_other_electric_equipment -performing_arts_dressing_room_electric_equipment -electrical_mechanical_electric_equipment -emergency_room_electric_equipment -emergency_vehicle_garage_electric_equipment -exam_treatment_electric_equipment -gymnasium_exercise_area_electric_equipment -museum_exhibit_area_electric_equipment -guest_room_electric_equipment -parking_area_interior_electric_equipment -judges_chambers_electric_equipment -kitchen_electric_equipment -laboratory_electric_equipment -laundry_washing_electric_equipment -library_stacks_electric_equipment -dormitory_living_quarters_electric_equipment -lobby_all_other_electric_equipment -locker_room_electric_equipment -lounge_breakroom_all_other_electric_equipment -manufacturing_low_bay_electric_equipment -pharmacy_electric_equipment -patient_room_electric_equipment -nurses_station_electric_equipment -office_open_electric_equipment -office_enclosed_lte_250_sf_electric_equipment -operating_room_electric_equipment -physical_therapy_electric_equipment -gymnasium_playing_area_electric_equipment -plenum_electric_equipment -post_office_sorting_area_electric_equipment -restroom_all_other_electric_equipment -sales_electric_equipment -shaft_electric_equipment -firestation_sleeping_quarters_electric_equipment -sports_arena_playing_area_class_ii_electric_equipment -stairwell_electric_equipment -storage_50_to_1000_sf_all_other_electric_equipment -transportation_ticket_counter_electric_equipment -vehicular_maintenance_electric_equipment -workshop_electric_equipment -worship_pulpit_choir_area_electric_equipment -datacenter_high_ite_equipment -datacenter_low_ite_equipment -multifamily_equipment -imaging_room_equipment -loading_dock_equipment diff --git a/data/openstudio_standards_data/database_files/support_lighting_space_type_name_tags.csv b/data/openstudio_standards_data/database_files/support_lighting_space_type_name_tags.csv deleted file mode 100644 index b7d064fb58..0000000000 --- a/data/openstudio_standards_data/database_files/support_lighting_space_type_name_tags.csv +++ /dev/null @@ -1,119 +0,0 @@ -lighting_space_type_name -airport_concourse_lighting -atrium_lighting -none_lighting -audience_seating_lighting -baggage_carousel_lighting -banking_lighting -classroom_lecture_training_lighting -computer_room_lighting -conference_meeting_multipurpose_lighting -confinement_cells_lighting -copy_print_lighting -corridor_lighting -courtroom_lighting -datacenterhighite_lighting -datacenterlowite_lighting -dining_lighting -dressing_room_lighting -electrical_mechanical_lighting -emergency_room_lighting -emergency_vehicle_garage_lighting -exam_treatment_lighting -exercise_area_lighting -exhibit_lighting -guest_room_lighting -imaging_lighting -interior_parking_lighting -judges_chambers_lighting -food_preparation_lighting -laboratory_lighting -laundry_washing_lighting -library_lighting -living_quarters_lighting -loading_dock_lighting -lobby_lighting -locker_room_lighting -lounge_breakroom_lighting -manufacturing_lighting -medical_supply_lighting -multifamily_lighting -nursery_lighting -nurses_station_lighting -office_lighting -office_enclosed_lighting -operating_room_lighting -patient_room_lighting -pharmacy_lighting -physical_therapy_lighting -playing_area_lighting -post_office_lighting -recovery_lighting -recreation_common_living_lighting -restroom_lighting -retail_sales_lighting -sleeping_quarters_lighting -sports_arena_lighting -stairwell_lighting -storage_lighting -transportation_lighting -vehicular_maintenance_lighting -workshop_lighting -worship_lighting -ba_automotive_facility_lighting -ba_convention_center_lighting -ba_courthouse_lighting -ba_dining_bar_lounge_leisure_lighting -ba_dining_cafeteria_fast_food_lighting -ba_dining_family_lighting -ba_dormitory_lighting -ba_exercise_center_lighting -ba_fire_station_lighting -ba_gymnasium_lighting -ba_health-care_clinic_lighting -ba_hospital_lighting -ba_hotel_motel_lighting -ba_motion_picture_theater_lighting -ba_museum_lighting -ba_parking_garage_lighting -ba_penitentiary_lighting -ba_performing_arts_theater_lighting -ba_police_station_lighting -ba_school_university_lighting -ba_town_hall_lighting -ba_retail_lighting -ba_warehouse_lighting -audience_seating_area_for_gymnasium_lighting -audience_seating_area_for_motion_picture_theater_lighting -audience_seating_area_for_penitentiary_lighting -audience_seating_area_for_performing_arts_theater_lighting -audience_seating_area_for_religious_buildings_lighting -audience_seating_area_for_sports_arena_lighting -classroom_lecture_training_for_penitentiary_lighting -corridor_transition_for_hospital_lighting -dining_area_for_penitentiary_lighting -dining_bar_lounge_leisure_general_lighting -dining_cafeteria_fast_food_general_lighting -dining_area_for_family_dining_lighting -lobby_for_hotel_lighting -lobby_for_motion_picture_theater_lighting -lobby_for_performing_arts_theater_lighting -lounge_recreation_for_hospital_lighting -office-enclosed_general_lighting -office_open_plan_lighting -automotive_general_lighting -convention_center_exhibit_space_general_lighting -library_reading_area_lighting -library_stacks_lighting -manufacturing_facility_detailed_manufacturing_area_lighting -manufacturing_facility_equipment_room_lighting -manufacturing_facility_high_bay_area_25_to_50_ft_ftc_hgt_lighting -manufacturing_facility_low_bay_area_lt_25_ft_ftc_hgt_lighting -museum_restoration_room_lighting -post_office_sorting_area_general_lighting -religious_buildings_fellowship_hall_lighting -religious_buildings_worship_pulpit_choir_lighting -retail_mall_concourse_lighting -transportation_facility_ticket_counter_lighting -warehouse_storage_area_medium_to_bulky_palletized_items_lighting -warehouse_storage_area_smaller_hand-carried_items_lighting diff --git a/data/openstudio_standards_data/database_files/support_lighting_technologies.csv b/data/openstudio_standards_data/database_files/support_lighting_technologies.csv deleted file mode 100644 index 00ce10f852..0000000000 --- a/data/openstudio_standards_data/database_files/support_lighting_technologies.csv +++ /dev/null @@ -1,2 +0,0 @@ -lighting_technology_definition_name,lighting_fraction_to_return_air,lighting_fraction_radiant,lighting_fraction_visible,lighting_fraction_replaceable,lpd_fraction_linear_fluorescent,lpd_fraction_compact_fluorescent,lpd_fraction_high_bay,lpd_fraction_specialty_lighting,lpd_fraction_exit_lighting,compact_fluorescent_lighting_schedule,high_bay_lighting_schedule,specialty_lighting_schedule,exit_lighting_schedule -default,0,0.7,0.2,1,1,0,0,0,0,,,, diff --git a/data/openstudio_standards_data/database_files/support_materials.csv b/data/openstudio_standards_data/database_files/support_materials.csv deleted file mode 100644 index 304cf74d9d..0000000000 --- a/data/openstudio_standards_data/database_files/support_materials.csv +++ /dev/null @@ -1,1390 +0,0 @@ -name,material_type,roughness,thickness,conductivity,resistance,density,specific_heat,thermal_absorptance,solar_absorptance,visible_absorptance,gas_type,u_factor,solar_heat_gain_coefficient,visible_transmittance,optical_data_type,solar_transmittance_at_normal_incidence,front_side_solar_reflectance_at_normal_incidence,back_side_solar_reflectance_at_normal_incidence,visible_transmittance_at_normal_incidence,front_side_visible_reflectance_at_normal_incidence,back_side_visible_reflectance_at_normal_incidence,infrared_transmittance_at_normal_incidence,front_side_infrared_hemispherical_emissivity,back_side_infrared_hemispherical_emissivity,dirt_correction_factor_for_solar_and_visible_transmittance,solar_diffusing,frame_width,annotation -1 Coat Stucco,StandardOpaqueMaterial,MediumRough,0.38,5.0004,0.07599392,115.81,0.2,,,,,,,,,,,,,,,,,,,,, -1/2 in. Gypsum Board,StandardOpaqueMaterial,Smooth,0.5,1.109355488,0.450712153,49.94236846,0.260342027,0.9,0.7,0.5,,,,,,,,,,,,,,,,,, -1/2IN Gypsum,StandardOpaqueMaterial,Smooth,0.5,1.109355488,0.450712153,48.99970626,0.198242094,0.9,0.4,0.4,,,,,,,,,,,,,,,,,, -10 PSF Roof - 1 in.,StandardOpaqueMaterial,VeryRough,1,12.0048,0.083300013,120,0.2,,,,,,,,,,,,,,,,,,,,, -100mm Normalweight concrete floor,StandardOpaqueMaterial,MediumRough,4,16.0194175,0.249696969,144.957816,0.198852772,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -12 in. Normalweight Concrete Floor,StandardOpaqueMaterial,MediumRough,12,16.01631985,0.749235786,144.9577245,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -15 PSF Roof - 1 1/2 in.,StandardOpaqueMaterial,VeryRough,1.5,18.0072,0.083300013,120,0.2,,,,,,,,,,,,,,,,,,,,, -1IN Stucco,StandardOpaqueMaterial,Smooth,0.996062992,4.79657579,0.207661264,115.9911508,0.199914015,0.9,0.7,0.92,,,,,,,,,,,,,,,,,, -25 PSF Roof - 2 1/2 in.,StandardOpaqueMaterial,VeryRough,2.5,30.012,0.083300013,120,0.2,,,,,,,,,,,,,,,,,,,,, -25mm Stucco,StandardOpaqueMaterial,Smooth,1,4.992099695,0.200316512,115.8662948,0.200630553,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -3 Coat Stucco,StandardOpaqueMaterial,MediumRough,0.88,4.3752,0.201133662,116,0.2,,,,,,,,,,,,,,,,,,,,, -4 in. Normalweight Concrete Floor,StandardOpaqueMaterial,MediumRough,4,16.01631985,0.249745262,144.9577245,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -4 in. Normalweight Concrete Wall,StandardOpaqueMaterial,MediumRough,4,16.01631985,0.249745262,144.9577245,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -5 PSF Roof - 1/2 in.,StandardOpaqueMaterial,VeryRough,0.5,6.0024,0.083300013,120,0.2,,,,,,,,,,,,,,,,,,,,, -5/8 in. Gypsum Board,StandardOpaqueMaterial,MediumSmooth,0.625984252,1.109355488,0.56427742,49.94236846,0.260342027,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -5/8 in. Plywood,StandardOpaqueMaterial,Smooth,0.625984252,0.832016616,0.752369893,33.96081055,0.289003535,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -6 in. Heavyweight Concrete Roof,StandardOpaqueMaterial,MediumRough,6,16.01631985,0.374617893,144.9577245,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -6 in. Normalweight Concrete Floor,StandardOpaqueMaterial,MediumRough,6,16.01631985,0.374617893,144.9577245,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -8 in. Concrete Block Basement Wall,StandardOpaqueMaterial,MediumRough,8,9.193783605,0.870153176,114.9923034,0.217827458,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -8 in. Concrete Block Wall,StandardOpaqueMaterial,MediumRough,8,4.992099695,1.602532098,49.94236846,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -8 in. Normalweight Concrete Floor,StandardOpaqueMaterial,MediumRough,8,16.01631985,0.499490524,144.9577245,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -8 in. Normalweight Concrete Wall,StandardOpaqueMaterial,MediumRough,8,16.01631985,0.499490524,144.9577245,0.198719786,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -8IN Concrete HW,StandardOpaqueMaterial,MediumRough,8.003937008,11.99213282,0.667432318,140.0259156,0.199914015,0.9,0.65,0.65,,,,,,,,,,,,,,,,,, -8IN CONCRETE HW RefBldg,StandardOpaqueMaterial,Rough,8,9.089781528,0.880109162,139.8386317,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Acoustic Ceiling,StandardOpaqueMaterial,MediumSmooth,0.5,0.395207893,1.26515692,17.97925265,0.319814656,0.9,0.7,0.2,,,,,,,,,,,,,,,,,, -Acoustic Tile - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,0.3996,1.251251251,18,0.19,,,,,,,,,,,,,,,,,,,,, -Acoustic Tile - 3/4 in.,StandardOpaqueMaterial,MediumSmooth,0.75,0.3996,1.876876877,18,0.19,,,,,,,,,,,,,,,,,,,,, -Acoustic Tile - 3/8 in.,StandardOpaqueMaterial,MediumSmooth,0.38,0.39,0.974358974,18,0.19,,,,,,,,,,,,,,,,,,,,, -Adiabatic Material,MasslessOpaqueMaterial,,,,9999,,,,,,,,,,,,,,,,,,,,,,, -Aggregate - 45 lb/ft3 - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,1.56,0.320512821,45,0.32,,,,,,,,,,,,,,,,,,,,, -Aggregate - 45 lb/ft3 - 5/8 in.,StandardOpaqueMaterial,MediumSmooth,0.63,1.5996,0.393848462,45,0.32,,,,,,,,,,,,,,,,,,,,, -Aggregate - 45 lb/ft3 - on metal lath - 3/4 in.,StandardOpaqueMaterial,MediumSmooth,0.75,1.5996,0.468867217,45,0.32,,,,,,,,,,,,,,,,,,,,, -Aggregate - Perlite - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,1.2996,0.384733764,45,0.32,,,,,,,,,,,,,,,,,,,,, -Aggregate - Perlite - 5/8 in.,StandardOpaqueMaterial,Smooth,0.63,1.5,0.42,45,0.32,,,,,,,,,,,,,,,,,,,,, -Aggregate - Perlite - on metal lath - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,1.7004,0.441072689,45,0.32,,,,,,,,,,,,,,,,,,,,, -Air - Cavity - Wall Roof Ceiling - 4 in. or more,StandardOpaqueMaterial,Smooth,6,6.5196,0.920301859,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Ceiling - 1 1/2 in.,StandardOpaqueMaterial,Smooth,1.5,1.95,0.769230769,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Ceiling - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.6804,0.734861846,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Ceiling - 3 1/2 in.,StandardOpaqueMaterial,Smooth,3.5,4.38,0.799086758,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Ceiling - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,0.9996,0.75030012,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Floor - 1 1/2 in.,StandardOpaqueMaterial,Smooth,1.5,1.5996,0.937734434,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Floor - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.6504,0.768757688,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Floor - 3 1/2 in.,StandardOpaqueMaterial,Smooth,3.5,3.5004,0.999885727,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Floor - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,0.8796,0.8526603,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Metal Wall Framing - 16 or 24 in. OC,StandardOpaqueMaterial,Smooth,5.5,8.46,0.650118203,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Roof - 1 1/2 in.,StandardOpaqueMaterial,Smooth,1.5,1.8804,0.797702616,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Roof - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.66,0.757575758,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Roof - 3 1/2 in.,StandardOpaqueMaterial,Smooth,3.5,4.2696,0.819748923,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Roof - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,0.93,0.806451613,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Wall - 1 1/2 in.,StandardOpaqueMaterial,Smooth,1.5,1.7196,0.872295883,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Wall - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.6504,0.768757688,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Wall - 3 1/2 in.,StandardOpaqueMaterial,Smooth,3.5,4.1196,0.849597048,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -Air - Wall - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,0.8904,0.842318059,0.08,0.24,,,,,,,,,,,,,,,,,,,,, -AIR 13MM,Gas,,0.5,,,,,,,,Air,,,,,,,,,,,,,,,,, -AIR 3MM,Gas,,0.125984252,,,,,,,,Air,,,,,,,,,,,,,,,,, -AIR 6MM,Gas,,0.248031496,,,,,,,,Air,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Double glass with no low e - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.9,2.522222222,29.09,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Double glass with no low e - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.8196,3.989751098,20.44,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Double glass with no low e - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,1.08,4.138888889,15.23,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Double glass with no low e - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,1.3296,4.264440433,12.22,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Double glass with no low e - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,1.5996,4.294823706,10.26,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Double glass with no low e - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.8504,4.361219196,8.88,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Double glass with no low e - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.5304,3.450226244,35.69,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Double glass with no low e - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.6696,3.808243728,25.92,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - No Ins.,StandardOpaqueMaterial,Smooth,2.27,1.1796,1.924381146,29.09,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.8496,3.848870056,20.44,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,1.1004,4.062159215,15.23,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,1.35,4.2,12.22,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,1.6104,4.266020864,10.26,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.86,4.338709677,8.88,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.5604,3.265524625,35.69,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Single glass pane. stone. or metal pane - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.6996,3.644939966,25.92,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Triple or low e glass - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.78,2.91025641,29.09,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Triple or low e glass - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.8196,3.989751098,20.44,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Triple or low e glass - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,1.08,4.138888889,15.23,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Triple or low e glass - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,1.3296,4.264440433,12.22,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Triple or low e glass - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,1.5996,4.294823706,10.26,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Triple or low e glass - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.8504,4.361219196,8.88,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Triple or low e glass - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.51,3.588235294,35.69,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/ Thrml Break - Triple or low e glass - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.6696,3.808243728,25.92,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Double glass with no low e coatings - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.8304,2.733622351,29.09,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Double glass with no low e coatings - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.6504,5.027675277,20.44,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Double glass with no low e coatings - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.8304,5.382947977,15.23,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Double glass with no low e coatings - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,1.00464,5.643812709,12.22,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Double glass with no low e coatings - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,1.1904,5.771169355,10.26,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Double glass with no low e coatings - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.3704,5.888791594,8.88,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Double glass with no low e coatings - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.4404,4.155313351,35.69,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Double glass with no low e coatings - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.54,4.722222222,25.92,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - No Ins.,StandardOpaqueMaterial,Smooth,2.27,1.1304,2.008138712,29.09,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.66,4.954545455,20.44,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.84,5.321428571,15.23,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,1.0104,5.611638955,12.22,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,1.1904,5.771169355,10.26,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.38,5.847826087,8.88,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.4704,3.890306122,35.69,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Single glass pane. stone. or metal pane - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.5604,4.550321199,25.92,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Triple or low e glass - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.69,3.289855072,29.09,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Triple or low e glass - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.63648,5.137631976,20.44,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Triple or low e glass - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.8196,5.453879941,15.23,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Triple or low e glass - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,0.9996,5.672268908,12.22,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Triple or low e glass - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,1.1796,5.824008138,10.26,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Triple or low e glass - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.3704,5.888791594,8.88,0.27,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Triple or low e glass - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.41724,4.385964912,35.69,0.26,,,,,,,,,,,,,,,,,,,,, -Aluminum w/out Thrml Break - Triple or low e glass - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.5304,4.807692308,25.92,0.26,,,,,,,,,,,,,,,,,,,,, -ARGON 13MM,Gas,,0.5,,,,,,,,Argon,,,,,,,,,,,,,,,,, -Asbestos or cement shingles - 3/8 in.,StandardOpaqueMaterial,VeryRough,0.38,1.7904,0.212243074,120,0.24,,,,,,,,,,,,,,,,,,,,, -Ash - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,1.1004,0.908760451,40.06,0.39,,,,,,,,,,,,,,,,,,,,, -Asphalt - bitumen with inert fill - 100 lb/ft3 - 3/4 in.,StandardOpaqueMaterial,VeryRough,0.75,3,0.25,100,0.3,,,,,,,,,,,,,,,,,,,,, -Asphalt - bitumen with inert fill - 144 lb/ft3 - 3/4 in.,StandardOpaqueMaterial,VeryRough,0.75,8.0004,0.093745313,144,0.3,,,,,,,,,,,,,,,,,,,,, -Asphalt roll roofing - 1/4 in.,StandardOpaqueMaterial,VeryRough,0.25,1.6704,0.149664751,70,0.36,,,,,,,,,,,,,,,,,,,,, -Asphalt Shingles,StandardOpaqueMaterial,VeryRough,0.125984252,0.277338872,0.454261067,69.91931585,0.30094583,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Asphalt shingles - 1/4 in.,StandardOpaqueMaterial,VeryRough,0.25,0.5604,0.446109921,69.89,0.3,,,,,,,,,,,,,,,,,,,,, -AtticFloor Insulation,StandardOpaqueMaterial,MediumRough,9.366141732,0.339740118,27.56854794,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Birch - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,1.1904,0.840053763,43.93,0.39,,,,,,,,,,,,,,,,,,,,, -BLUE 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.48,0.05,0.05,0.57,0.06,0.06,0,0.84,0.84,1,FALSE,, -Brick - 48 lb/ft3 - 3 5/8 in.,StandardOpaqueMaterial,Rough,3.63,1.5,2.42,48,0.19,,,,,,,,,,,,,,,,,,,,, -Brick - fired clay - 140 lb/ft3 - 3 5/8 in.,StandardOpaqueMaterial,MediumRough,3.63,8.22,0.441605839,139.78,0.19,,,,,,,,,,,,,,,,,,,,, -BRONZE 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.482,0.054,0.054,0.534,0.057,0.057,0,0.84,0.84,1,FALSE,, -Building Paper - 1/16 in.,StandardOpaqueMaterial,MediumSmooth,0.06,2.0004,0.029994001,70,0.3,,,,,,,,,,,,,,,,,,,,, -Built-up Roofing,StandardOpaqueMaterial,Rough,0.374015748,1.109355488,0.337146886,69.91931585,0.348715009,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Built-up roofing - 3/8 in.,StandardOpaqueMaterial,VeryRough,0.38,1.14,0.333333333,70,0.35,,,,,,,,,,,,,,,,,,,,, -Built-up Roofing - Highly Reflective,StandardOpaqueMaterial,Rough,0.374015748,1.109355488,0.337146886,69.91931585,0.348715009,0.75,0.45,0.7,,,,,,,,,,,,,,,,,, -Bulk Storage Products Material,StandardOpaqueMaterial,Rough,96.0001946,9.998066642,9.601875846,12.49999184,0.199866248,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -California Redwood - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,0.78,1.282051282,26.21,0.39,,,,,,,,,,,,,,,,,,,,, -Carpet - 3/4 in.,StandardOpaqueMaterial,Rough,0.75,0.3156,2.376425856,18,0.33,,,,,,,,,,,,,,,,,,,,, -Carpet - 3/4 in. CBES,StandardOpaqueMaterial,Smooth,0.75,0.34691,,18,0.33,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -ceiling_2_Insulation,StandardOpaqueMaterial,Smooth,3.96766,0.15963,,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 1 1/2 in. R8.8,StandardOpaqueMaterial,Rough,1.5,0.1704,8.802816901,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 1 in. R5.9,StandardOpaqueMaterial,Rough,1,0.1704,5.868544601,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 1/2 in. R2.9,StandardOpaqueMaterial,Rough,0.5,0.1704,2.9342723,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 1/4 in. R1.5,StandardOpaqueMaterial,Rough,0.25,0.1704,1.46713615,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 1/8 in. R0.7,StandardOpaqueMaterial,Rough,0.13,0.1704,0.762910798,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 2 1/2 in. R15,StandardOpaqueMaterial,Rough,2.5,0.1704,14.6713615,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 2 in. R12,StandardOpaqueMaterial,Rough,2,0.1704,11.7370892,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 3 1/2 in. R21,StandardOpaqueMaterial,Rough,3.5,0.1704,20.5399061,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 3 in. R18,StandardOpaqueMaterial,Rough,3,0.1704,17.6056338,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 4 1/2 in. R26,StandardOpaqueMaterial,Rough,4.5,0.1704,26.4084507,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 4 in. R23,StandardOpaqueMaterial,Rough,4,0.1704,23.4741784,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 5 1/2 in. R32,StandardOpaqueMaterial,Rough,5.5,0.1704,32.27699531,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 5 in. R29,StandardOpaqueMaterial,Rough,5,0.1704,29.342723,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 6 1/2 in. R38,StandardOpaqueMaterial,Rough,6.5,0.1704,38.14553991,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Cellular polyisocyanurate (unfaced) - 6 in. R35,StandardOpaqueMaterial,Rough,6,0.1704,35.21126761,1.5,0.38,,,,,,,,,,,,,,,,,,,,, -Clay - Part Grouted and Empty - 130 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.12,1.923076923,130,0.13,,,,,,,,,,,,,,,,,,,,, -Clay - Part Grouted and Empty - 130 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,3.7596,2.127885945,130,0.13,,,,,,,,,,,,,,,,,,,,, -Clay - Part Grouted and Insulated - 130 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,2.7,2.222222222,130,0.13,,,,,,,,,,,,,,,,,,,,, -Clay - Part Grouted and Insulated - 130 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,3.12,2.564102564,130,0.13,,,,,,,,,,,,,,,,,,,,, -Clay - Solid Grout - 130 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.9,1.538461538,130,0.17,,,,,,,,,,,,,,,,,,,,, -Clay - Solid Grout - 130 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,4.56,1.754385965,130,0.17,,,,,,,,,,,,,,,,,,,,, -Clay tile - 1/2 in.,StandardOpaqueMaterial,MediumRough,0.5,0.1896,2.637130802,85,0.21,,,,,,,,,,,,,,,,,,,,, -Clay tile - hollow - 1 cell deep - 3 in.,StandardOpaqueMaterial,MediumRough,3,3.75,0.8,85,0.21,,,,,,,,,,,,,,,,,,,,, -Clay tile - hollow - 1 cell deep - 4 in.,StandardOpaqueMaterial,MediumRough,4,3.6,1.111111111,85,0.21,,,,,,,,,,,,,,,,,,,,, -Clay tile - hollow - 2 cells deep - 10 in.,StandardOpaqueMaterial,MediumRough,10,4.5,2.222222222,85,0.21,,,,,,,,,,,,,,,,,,,,, -Clay tile - hollow - 2 cells deep - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.9504,1.518833536,85,0.21,,,,,,,,,,,,,,,,,,,,, -Clay tile - hollow - 2 cells deep - 8 in.,StandardOpaqueMaterial,MediumRough,8,4.32,1.851851852,85,0.21,,,,,,,,,,,,,,,,,,,,, -Clay tile - hollow - 3 cells deep - 12 in.,StandardOpaqueMaterial,MediumRough,12,4.8,2.5,85,0.21,,,,,,,,,,,,,,,,,,,,, -Clay Tile - Paver,StandardOpaqueMaterial,MediumRough,0.38,12.504,0.030390275,139.78,0.22,,,,,,,,,,,,,,,,,,,,, -CLEAR 2.5MM,StandardGlazing,,0.098425197,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.8,0.075,0.075,0.901,0.081,0.081,0,0.84,0.84,1,FALSE,, -CLEAR 3MM,StandardGlazing,,0.118110236,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.837,0.075,0.075,0.898,0.081,0.081,0,0.84,0.84,1,FALSE,, -CLEAR 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.775,0.071,0.071,0.881,0.08,0.08,0,0.84,0.84,1,FALSE,, -COATED POLY-55,StandardGlazing,,0.02007874,0.970686052,1.030199206,,,,,,,,,,SpectralAverage,0.32,0.582,0.593,0.551,0.336,0.375,0,0.046,0.72,1,FALSE,, -COATED POLY-77,StandardGlazing,,0.02007874,0.970686052,1.030199206,,,,,,,,,,SpectralAverage,0.504,0.402,0.398,0.766,0.147,0.167,0,0.075,0.72,1,FALSE,, -Compliance Insulation R0.01,StandardOpaqueMaterial,MediumSmooth,0.0016,0.1596,0.010025063,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R0.02,StandardOpaqueMaterial,MediumSmooth,0.0032,0.1596,0.020050125,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R0.10,StandardOpaqueMaterial,MediumSmooth,0.016,0.1596,0.100250627,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R1.35,StandardOpaqueMaterial,MediumSmooth,0.216,0.1596,1.353383459,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R1.41,StandardOpaqueMaterial,MediumSmooth,0.2256,0.1596,1.413533835,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R1.54,StandardOpaqueMaterial,MediumSmooth,0.2464,0.1596,1.543859649,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R10.06,StandardOpaqueMaterial,MediumSmooth,1.6096,0.1596,10.08521303,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R12.55,StandardOpaqueMaterial,MediumSmooth,2.008,0.1596,12.58145363,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R12.69,StandardOpaqueMaterial,MediumSmooth,2.0304,0.1596,12.72180451,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R13.99,StandardOpaqueMaterial,MediumSmooth,2.2384,0.1596,14.02506266,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R14.14,StandardOpaqueMaterial,MediumSmooth,2.2624,0.1596,14.1754386,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R14.32,StandardOpaqueMaterial,MediumSmooth,2.2912,0.1596,14.35588972,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R14.60,StandardOpaqueMaterial,MediumSmooth,2.336,0.1596,14.63659148,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R15.54,StandardOpaqueMaterial,MediumSmooth,2.4864,0.1596,15.57894737,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R16.58,StandardOpaqueMaterial,MediumSmooth,2.6528,0.1596,16.62155388,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R16.69,StandardOpaqueMaterial,MediumSmooth,2.6704,0.1596,16.73182957,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R17.67,StandardOpaqueMaterial,MediumSmooth,2.8272,0.1596,17.71428571,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R19.63,StandardOpaqueMaterial,MediumSmooth,3.1408,0.1596,19.67919799,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R2.15,StandardOpaqueMaterial,MediumSmooth,0.344,0.1596,2.155388471,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R2.19,StandardOpaqueMaterial,MediumSmooth,0.3504,0.1596,2.195488722,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R2.85,StandardOpaqueMaterial,MediumSmooth,0.456,0.1596,2.857142857,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R2.89,StandardOpaqueMaterial,MediumSmooth,0.4624,0.1596,2.897243108,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R20.05,StandardOpaqueMaterial,MediumSmooth,3.208,0.1596,20.10025063,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R21.18,StandardOpaqueMaterial,MediumSmooth,3.3888,0.1596,21.23308271,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R21.39,StandardOpaqueMaterial,MediumSmooth,3.4224,0.1596,21.44360902,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R22.48,StandardOpaqueMaterial,MediumSmooth,3.5968,0.1596,22.53634085,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R24.86,StandardOpaqueMaterial,MediumSmooth,3.9776,0.1596,24.92230576,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R25.16,StandardOpaqueMaterial,MediumSmooth,4.0256,0.1596,25.22305764,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R28.63,StandardOpaqueMaterial,MediumSmooth,4.5808,0.1596,28.70175439,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R3.63,StandardOpaqueMaterial,MediumSmooth,0.5808,0.1596,3.639097744,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R3.70,StandardOpaqueMaterial,MediumSmooth,0.592,0.1596,3.709273183,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R34.93,StandardOpaqueMaterial,MediumSmooth,5.5888,0.1596,35.01754386,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R6.32,StandardOpaqueMaterial,MediumSmooth,1.0112,0.1596,6.335839599,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R6.46,StandardOpaqueMaterial,MediumSmooth,1.0336,0.1596,6.476190476,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R7.10,StandardOpaqueMaterial,MediumSmooth,1.136,0.1596,7.117794486,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R7.18,StandardOpaqueMaterial,MediumSmooth,1.1488,0.1596,7.197994987,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R7.39,StandardOpaqueMaterial,MediumSmooth,1.1824,0.1596,7.408521303,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R8.00,StandardOpaqueMaterial,MediumSmooth,1.28,0.1596,8.020050125,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R8.07,StandardOpaqueMaterial,MediumSmooth,1.2912,0.1596,8.090225564,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R9.83,StandardOpaqueMaterial,MediumSmooth,1.5697,0.1596,9.835213033,1,0.27,,,,,,,,,,,,,,,,,,,,, -Compliance Insulation R9.94,StandardOpaqueMaterial,MediumSmooth,1.5904,0.1596,9.964912281,1,0.27,,,,,,,,,,,,,,,,,,,,, -Concrete - 100 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,6.2496,1.600102407,100,0.21,,,,,,,,,,,,,,,,,,,,, -Concrete - 100 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,6.2496,1.920122888,100,0.21,,,,,,,,,,,,,,,,,,,,, -Concrete - 100 lb/ft3 - 2 in.,StandardOpaqueMaterial,MediumRough,2,6.2496,0.320020481,100,0.21,,,,,,,,,,,,,,,,,,,,, -Concrete - 100 lb/ft3 - 4 in.,StandardOpaqueMaterial,MediumRough,4,6.2496,0.640040963,100,0.21,,,,,,,,,,,,,,,,,,,,, -Concrete - 100 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,6.2496,0.960061444,100,0.21,,,,,,,,,,,,,,,,,,,,, -Concrete - 100 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,6.2496,1.280081925,100,0.21,,,,,,,,,,,,,,,,,,,,, -Concrete - 140 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,13.53,0.7390983,139.78,0.22,,,,,,,,,,,,,,,,,,,,, -Concrete - 140 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,13.53,0.88691796,139.78,0.22,,,,,,,,,,,,,,,,,,,,, -Concrete - 140 lb/ft3 - 2 in.,StandardOpaqueMaterial,MediumRough,2,13.53,0.14781966,139.78,0.22,,,,,,,,,,,,,,,,,,,,, -Concrete - 140 lb/ft3 - 4 in.,StandardOpaqueMaterial,MediumRough,4,13.53,0.29563932,139.78,0.22,,,,,,,,,,,,,,,,,,,,, -Concrete - 140 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,13.53,0.44345898,139.78,0.22,,,,,,,,,,,,,,,,,,,,, -Concrete - 140 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,13.53,0.59127864,139.78,0.22,,,,,,,,,,,,,,,,,,,,, -Concrete - 80 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,3.6804,2.717095968,79.87,0.2,,,,,,,,,,,,,,,,,,,,, -Concrete - 80 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,3.6804,3.260515161,79.87,0.2,,,,,,,,,,,,,,,,,,,,, -Concrete - 80 lb/ft3 - 2 in.,StandardOpaqueMaterial,MediumRough,2,3.6804,0.543419194,79.87,0.2,,,,,,,,,,,,,,,,,,,,, -Concrete - 80 lb/ft3 - 4 in.,StandardOpaqueMaterial,MediumRough,4,3.6804,1.086838387,79.87,0.2,,,,,,,,,,,,,,,,,,,,, -Concrete - 80 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.6804,1.630257581,79.87,0.2,,,,,,,,,,,,,,,,,,,,, -Concrete - 80 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,3.6804,2.173676774,79.87,0.2,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Empty - 105 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,4.5996,2.174102096,105,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Empty - 105 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,5.16,2.325581395,105,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Empty - 105 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.24,1.851851852,105,0.15,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Empty - 105 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,3.9996,2.00020002,105,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Empty - 115 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,4.8996,2.040982937,115,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Empty - 115 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,5.52,2.173913043,115,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Empty - 115 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.48,1.724137931,115,0.15,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Empty - 115 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,4.2396,1.886970469,115,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Empty - 125 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,5.1996,1.923224863,125,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Empty - 125 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,5.88,2.040816327,125,0.13,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Empty - 125 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.66,1.639344262,125,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Empty - 125 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,4.4796,1.785873739,125,0.13,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Insulated - 105 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,3.3996,2.941522532,105,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Insulated - 105 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,3.6,3.333333333,105,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Insulated - 105 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,2.64,2.272727273,105,0.15,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Insulated - 105 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,2.9604,2.702337522,105,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Insulated - 115 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,3.6996,2.702994918,115,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Insulated - 115 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,3.96,3.03030303,115,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Insulated - 115 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,2.88,2.083333333,115,0.15,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Insulated - 115 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,3.2796,2.439321869,115,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Insulated - 125 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,4.1004,2.43878646,125,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Insulated - 125 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,4.32,2.777777778,125,0.13,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Insulated - 125 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,3.12,1.923076923,125,0.14,,,,,,,,,,,,,,,,,,,,, -Concrete - Part Grouted and Insulated - 125 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,3.5196,2.272985567,125,0.13,,,,,,,,,,,,,,,,,,,,, -Concrete - Solid Grout - 105 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,8.4744,1.180024545,105,0.22,,,,,,,,,,,,,,,,,,,,, -Concrete - Solid Grout - 105 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,8.5704,1.40016802,105,0.22,,,,,,,,,,,,,,,,,,,,, -Concrete - Solid Grout - 105 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,8.3328,0.720046083,105,0.21,,,,,,,,,,,,,,,,,,,,, -Concrete - Solid Grout - 105 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,8.3328,0.960061444,105,0.22,,,,,,,,,,,,,,,,,,,,, -Concrete - Solid Grout - 115 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,9.174,1.090037061,115,0.21,,,,,,,,,,,,,,,,,,,,, -Concrete - Solid Grout - 115 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,9.2304,1.300052002,115,0.21,,,,,,,,,,,,,,,,,,,,, -Concrete - Solid Grout - 115 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,10.17,0.589970501,115,0.2,,,,,,,,,,,,,,,,,,,,, -Concrete - Solid Grout - 115 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,9.1224,0.876962203,115,0.2,,,,,,,,,,,,,,,,,,,,, -Concrete - Solid Grout - 125 lb/ft3 - 10 in.,StandardOpaqueMaterial,MediumRough,10,10.1016,0.989942187,125,0.2,,,,,,,,,,,,,,,,,,,,, -Concrete - Solid Grout - 125 lb/ft3 - 12 in.,StandardOpaqueMaterial,MediumRough,12,10.0836,1.190051172,125,0.2,,,,,,,,,,,,,,,,,,,,, -Concrete - Solid Grout - 125 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,10.17,0.589970501,125,0.19,,,,,,,,,,,,,,,,,,,,, -Concrete - Solid Grout - 125 lb/ft3 - 8 in.,StandardOpaqueMaterial,MediumRough,8,10.1268,0.789983015,125,0.2,,,,,,,,,,,,,,,,,,,,, -Concrete Paver,StandardOpaqueMaterial,MediumRough,0.38,4.5024,0.084399431,144,0.2,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 100% Ins. Layer - No Steel in Ins. - Ins. 1 1/2 in.,StandardOpaqueMaterial,MediumRough,13.5,1.8396,7.338551859,133.44,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 100% Ins. Layer - No Steel in Ins. - Ins. 2 in.,StandardOpaqueMaterial,MediumRough,14,1.4496,9.657836645,128.71,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 100% Ins. Layer - No Steel in Ins. - Ins. 3 in.,StandardOpaqueMaterial,MediumRough,15,1.05,14.28571429,120.2,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 100% Ins. Layer - No Steel in Ins. - Ins. 4 in.,StandardOpaqueMaterial,MediumRough,16,0.8496,18.83239171,112.75,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 100% Ins. Layer - No Steel in Ins. - Ins. 6 in.,StandardOpaqueMaterial,MediumRough,18,0.63,28.57142857,100.33,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 100% Ins. Layer - Steel in Ins. - Ins. 1 1/2 in.,StandardOpaqueMaterial,MediumRough,13.5,2.5704,5.25210084,133.44,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 100% Ins. Layer - Steel in Ins. - Ins. 2 in.,StandardOpaqueMaterial,MediumRough,14,2.01,6.965174129,128.71,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 100% Ins. Layer - Steel in Ins. - Ins. 3 in.,StandardOpaqueMaterial,MediumRough,15,1.4796,10.1378751,120.2,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 100% Ins. Layer - Steel in Ins. - Ins. 4 in.,StandardOpaqueMaterial,MediumRough,16,1.1904,13.44086022,112.75,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 100% Ins. Layer - Steel in Ins. - Ins. 6 in.,StandardOpaqueMaterial,MediumRough,18,0.9,20,100.33,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 80% Ins. Layer - No Steel in Ins. - Ins. 1 1/2 in.,StandardOpaqueMaterial,MediumRough,13.5,15.8604,0.851176515,133.44,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 80% Ins. Layer - No Steel in Ins. - Ins. 2 in.,StandardOpaqueMaterial,MediumRough,14,14.7504,0.949126803,128.71,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 80% Ins. Layer - No Steel in Ins. - Ins. 3 in.,StandardOpaqueMaterial,MediumRough,15,11.9904,1.251000801,120.2,0.12,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 80% Ins. Layer - No Steel in Ins. - Ins. 4 in.,StandardOpaqueMaterial,MediumRough,16,10.3404,1.547328923,112.75,0.12,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 80% Ins. Layer - No Steel in Ins. - Ins. 6 in.,StandardOpaqueMaterial,MediumRough,18,8.3604,2.153007033,100.33,0.13,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 80% Ins. Layer - Steel in Ins. - Ins. 1 1/2 in.,StandardOpaqueMaterial,MediumRough,13.5,15.8604,0.851176515,133.44,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 80% Ins. Layer - Steel in Ins. - Ins. 2 in.,StandardOpaqueMaterial,MediumRough,14,25.1796,0.556005655,128.71,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 80% Ins. Layer - Steel in Ins. - Ins. 3 in.,StandardOpaqueMaterial,MediumRough,15,31.5096,0.476045396,120.2,0.12,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 80% Ins. Layer - Steel in Ins. - Ins. 4 in.,StandardOpaqueMaterial,MediumRough,16,38.37,0.416992442,112.75,0.12,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 80% Ins. Layer - Steel in Ins. - Ins. 6 in.,StandardOpaqueMaterial,MediumRough,18,54.0504,0.333022512,100.33,0.13,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 90% Ins. Layer - No Steel in Ins. - Ins. 1 1/2 in.,StandardOpaqueMaterial,MediumRough,13.5,10.7904,1.2511121,133.44,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 90% Ins. Layer - No Steel in Ins. - Ins. 2 in.,StandardOpaqueMaterial,MediumRough,14,9.66,1.449275362,128.71,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 90% Ins. Layer - No Steel in Ins. - Ins. 3 in.,StandardOpaqueMaterial,MediumRough,15,7.32,2.049180328,120.2,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 90% Ins. Layer - No Steel in Ins. - Ins. 4 in.,StandardOpaqueMaterial,MediumRough,16,6.0396,2.649182065,112.75,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 90% Ins. Layer - No Steel in Ins. - Ins. 6 in.,StandardOpaqueMaterial,MediumRough,18,4.7904,3.75751503,100.33,0.12,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 90% Ins. Layer - Steel in Ins. - Ins. 1 1/2 in.,StandardOpaqueMaterial,MediumRough,13.5,11.7396,1.149954002,133.44,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 90% Ins. Layer - Steel in Ins. - Ins. 2 in.,StandardOpaqueMaterial,MediumRough,14,9.66,1.449275362,128.71,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 90% Ins. Layer - Steel in Ins. - Ins. 3 in.,StandardOpaqueMaterial,MediumRough,15,7.6896,1.950686642,120.2,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 90% Ins. Layer - Steel in Ins. - Ins. 4 in.,StandardOpaqueMaterial,MediumRough,16,6.5304,2.450079628,112.75,0.11,,,,,,,,,,,,,,,,,,,,, -Concrete Sandwich Panel - 90% Ins. Layer - Steel in Ins. - Ins. 6 in.,StandardOpaqueMaterial,MediumRough,18,5.0604,3.557031065,100.33,0.12,,,,,,,,,,,,,,,,,,,,, -Concrete/Sand Aggregate - 6 in.,StandardOpaqueMaterial,Smooth,6.01,4.29,1.400932401,116,0.2,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Double glass with no low e coatings - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.9,2.522222222,29.09,0.26,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Double glass with no low e coatings - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.26196,12.4828218,20.44,0.26,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Double glass with no low e coatings - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.25296,17.67077799,15.23,0.27,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Double glass with no low e coatings - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,0.25308,22.40398293,12.22,0.27,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Double glass with no low e coatings - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,0.2478,27.72397094,10.26,0.27,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Double glass with no low e coatings - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,0.2484,32.48792271,8.88,0.27,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Double glass with no low e coatings - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.2814,6.503198294,35.69,0.26,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Double glass with no low e coatings - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.27,9.444444444,25.92,0.26,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Single glass pane. stone. or metal pane - No Ins.,StandardOpaqueMaterial,Smooth,2.27,1.1796,1.924381146,29.09,0.26,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Single glass pane. stone. or metal pane - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.27312,11.97275923,20.44,0.26,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Single glass pane. stone. or metal pane - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.2628,17.00913242,15.23,0.27,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Single glass pane. stone. or metal pane - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,0.2592,21.875,12.22,0.27,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Single glass pane. stone. or metal pane - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,0.25512,26.92850423,10.26,0.27,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Single glass pane. stone. or metal pane - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,0.25692,31.41055582,8.88,0.27,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Single glass pane. stone. or metal pane - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.3096,5.910852713,35.69,0.26,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Single glass pane. stone. or metal pane - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.28476,8.954909397,25.92,0.26,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Triple or low e glass - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.78,2.91025641,29.09,0.26,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Triple or low e glass - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.25452,12.84771334,20.44,0.26,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Triple or low e glass - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.24804,18.02128689,15.23,0.27,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Triple or low e glass - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,0.24696,22.95918367,12.22,0.27,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Triple or low e glass - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,0.2478,27.72397094,10.26,0.27,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Triple or low e glass - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,0.2484,32.48792271,8.88,0.27,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Triple or low e glass - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.2652,6.900452489,35.69,0.26,,,,,,,,,,,,,,,,,,,,, -Continuous Ins. - Triple or low e glass - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.25752,9.902143523,25.92,0.26,,,,,,,,,,,,,,,,,,,,, -CP02 CARPET PAD,MasslessOpaqueMaterial,VeryRough,,,1.229230374,,,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -Douglas Fir-Larch - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,0.9804,1.01999184,34.88,0.39,,,,,,,,,,,,,,,,,,,,, -ECABS-2 BLEACHED 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.814,0.086,0.086,0.847,0.099,0.099,0,0.84,0.1,1,FALSE,, -ECABS-2 COLORED 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.111,0.179,0.179,0.128,0.081,0.081,0,0.84,0.1,1,FALSE,, -ECREF-1 COLORED 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.099,0.219,0.219,0.155,0.073,0.073,0,0.84,0.84,1,FALSE,, -ECREF-2 BLEACHED 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.694,0.168,0.168,0.818,0.11,0.11,0,0.84,0.1,1,FALSE,, -ECREF-2 COLORED 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.099,0.219,0.219,0.155,0.073,0.073,0,0.84,0.1,1,FALSE,, -Expanded perlite - organic bonded - 1 1/2 in. R4.2,StandardOpaqueMaterial,MediumSmooth,1.5,0.36,4.166666667,1,0.3,,,,,,,,,,,,,,,,,,,,, -Expanded perlite - organic bonded - 1 in. R2.8,StandardOpaqueMaterial,MediumSmooth,1,0.36,2.777777778,1,0.3,,,,,,,,,,,,,,,,,,,,, -Expanded perlite - organic bonded - 2 in. R5.6,StandardOpaqueMaterial,MediumSmooth,2,0.36,5.555555556,1,0.3,,,,,,,,,,,,,,,,,,,,, -Expanded perlite - organic bonded - 3 in. R8.3,StandardOpaqueMaterial,MediumSmooth,3,0.36,8.333333333,1,0.3,,,,,,,,,,,,,,,,,,,,, -Expanded perlite - organic bonded - 3/4 in. R2.1,StandardOpaqueMaterial,MediumSmooth,0.75,0.36,2.083333333,1,0.3,,,,,,,,,,,,,,,,,,,,, -Expanded perlite - organic bonded - 4 in. R11,StandardOpaqueMaterial,MediumSmooth,4,0.36,11.11111111,1,0.3,,,,,,,,,,,,,,,,,,,,, -Expanded perlite - organic bonded - 6 in. R17,StandardOpaqueMaterial,MediumSmooth,6,0.36,16.66666667,1,0.3,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 1 1/2 in. R6.3,StandardOpaqueMaterial,MediumSmooth,1.5,0.24,6.25,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 1 1/4 in. R5.2,StandardOpaqueMaterial,MediumSmooth,1.25,0.24,5.208333333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 1 15/16 in. R8.1,StandardOpaqueMaterial,MediumSmooth,1.94,0.24,8.083333333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 1 3/4 in. R7.3,StandardOpaqueMaterial,MediumSmooth,1.75,0.24,7.291666667,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 1 7/8 in. R8.0,StandardOpaqueMaterial,MediumSmooth,1.92,0.24,8,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 1 in. R4.2,StandardOpaqueMaterial,MediumSmooth,1,0.24,4.166666667,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 1/2 in. R2.1,StandardOpaqueMaterial,MediumSmooth,0.5,0.24,2.083333333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 1/4 in. R1.0,StandardOpaqueMaterial,MediumSmooth,0.25,0.24,1.041666667,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 2 2/5 in. R10,StandardOpaqueMaterial,MediumSmooth,2.4,0.24,10,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 2 7/16 in. R10,StandardOpaqueMaterial,MediumSmooth,2.43,0.24,10.125,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 2 in. R8.3,StandardOpaqueMaterial,MediumSmooth,2,0.24,8.333333333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 3 1/2 in. R15,StandardOpaqueMaterial,MediumSmooth,3.5,0.24,14.58333333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 3 1/3 in. R14,StandardOpaqueMaterial,MediumSmooth,3.35,0.24,13.95833333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 3 2/5 in. R14,StandardOpaqueMaterial,MediumSmooth,3.39,0.24,14.125,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 3 in. R13,StandardOpaqueMaterial,MediumSmooth,3.01,0.24,12.54166667,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 3/4 in. R3.1,StandardOpaqueMaterial,MediumSmooth,0.75,0.24,3.125,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 4 1/16 in. R17,StandardOpaqueMaterial,MediumSmooth,4.05,0.24,16.875,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 4 7/10 in. R20,StandardOpaqueMaterial,MediumSmooth,4.71,0.24,19.625,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 5 19/20 in. R25,StandardOpaqueMaterial,MediumSmooth,5.96,0.24,24.83333333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 5 2/5 in. R22,StandardOpaqueMaterial,MediumSmooth,5.2,0.24,21.66666667,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 6 1/10 in. R25,StandardOpaqueMaterial,MediumSmooth,6.11,0.24,25.45833333,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 6 7/8 in. R29,StandardOpaqueMaterial,MediumSmooth,6.87,0.24,28.625,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polystyrene - EPS - 8 3/5 in. R35,StandardOpaqueMaterial,MediumSmooth,8.38,0.24,34.91666667,1.2,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polyurethane - 1 1/4 in. R7.8,StandardOpaqueMaterial,MediumSmooth,1.25,0.1596,7.832080201,1,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polyurethane - 1 in. R6.3,StandardOpaqueMaterial,MediumSmooth,1,0.1596,6.26566416,1,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polyurethane - 1/2 in. R3.1,StandardOpaqueMaterial,MediumSmooth,0.5,0.1596,3.13283208,1,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polyurethane - 2 in. R12.6,StandardOpaqueMaterial,MediumSmooth,2,0.1596,12.53132832,1,0.27,,,,,,,,,,,,,,,,,,,,, -Expanded Polyurethane - 3/4 in. R4.7,StandardOpaqueMaterial,MediumSmooth,0.75,0.1596,4.69924812,1,0.27,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 1 1/2 in. R7.50,StandardOpaqueMaterial,MediumSmooth,1.5,0.200000004,7.49999985,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 1 1/4 in. R6.25,StandardOpaqueMaterial,MediumSmooth,1.25,0.200000004,6.249999875,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 1 3/4 in. R8.75,StandardOpaqueMaterial,MediumSmooth,1.75,0.200000004,8.749999825,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 1 7/8 in. R9.37,StandardOpaqueMaterial,MediumSmooth,1.88,0.200000004,9.399999812,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 1 in. R5.00,StandardOpaqueMaterial,MediumSmooth,1,0.200000004,4.9999999,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 1/2 in. R2.50,StandardOpaqueMaterial,MediumSmooth,0.5,0.200000004,2.49999995,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 1/4 in. R1.25,StandardOpaqueMaterial,MediumSmooth,0.25,0.200000004,1.249999975,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 2 1/2 in. R12.50,StandardOpaqueMaterial,MediumSmooth,2.5,0.200000004,12.49999975,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 2 in. R10.00,StandardOpaqueMaterial,MediumSmooth,2,0.200000004,9.9999998,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 3 1/2 in. R17.50,StandardOpaqueMaterial,MediumSmooth,3.5,0.200000004,17.49999965,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 3 in. R15.00,StandardOpaqueMaterial,MediumSmooth,3,0.200000004,14.9999997,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 3/4 in. R3.75,StandardOpaqueMaterial,MediumSmooth,0.75,0.200000004,3.749999925,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 4 1/2 in. R22.50,StandardOpaqueMaterial,MediumSmooth,4.5,0.200000004,22.49999955,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 4 in. R20.00,StandardOpaqueMaterial,MediumSmooth,4,0.200000004,19.9999996,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 5 1/2 in. R27.50,StandardOpaqueMaterial,MediumSmooth,5.5,0.200000004,27.49999945,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 5 in. R25.00,StandardOpaqueMaterial,MediumSmooth,5,0.200000004,24.9999995,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 6 1/2 in. R32.50,StandardOpaqueMaterial,MediumSmooth,6.5,0.200000004,32.49999935,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 6 in. R30.00,StandardOpaqueMaterial,MediumSmooth,6,0.200000004,29.9999994,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 8 1/2 in. R42.50,StandardOpaqueMaterial,MediumSmooth,8.5,0.200000004,42.49999915,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -Extruded Polystyrene - XPS - 8 in. R40.00,StandardOpaqueMaterial,MediumSmooth,8,0.200000004,39.9999992,1.3,0.35,,,,,,,,,,,,,,,,,,,,, -F04 Wall air space resistance,AirGap,,,46.22314532,0.021634183,,,,,,,,,,,,,,,,,,,,,,, -F05 Ceiling air space resistance,AirGap,,,38.51928777,0.02596102,,,,,,,,,,,,,,,,,,,,,,, -F08 Metal surface,StandardOpaqueMaterial,Smooth,0.031496063,313.947603,0.000100323,488.4363635,0.119422948,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -F16 Acoustic tile,StandardOpaqueMaterial,MediumSmooth,0.751968504,0.416008308,1.807580497,22.97348949,0.140919079,0.9,0.3,0.3,,,,,,,,,,,,,,,,,, -Fiber cement board - 63 lb/ft3 - 1/3 in.,StandardOpaqueMaterial,Smooth,0.31,1.2996,0.238534934,63,0.2,,,,,,,,,,,,,,,,,,,,, -Fiber cement board - 88 lb/ft3 - 1/2 in.,StandardOpaqueMaterial,Smooth,0.47,1.7004,0.276405552,88,0.2,,,,,,,,,,,,,,,,,,,,, -Fiber cement board - 88 lb/ft3 - 1/3 in.,StandardOpaqueMaterial,Smooth,0.31,1.7004,0.182310045,88,0.2,,,,,,,,,,,,,,,,,,,,, -Fiberboard sheathing - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.4896,1.02124183,24.96,0.31,,,,,,,,,,,,,,,,,,,,, -Fixed Window 2.00/0.40/0.31,SimpleGlazing,,,,,,,,,,,0.35,0.4,0.31,,,,,,,,,,,,,, -Fixed Window 2.00/0.45/0.35,SimpleGlazing,,,,,,,,,,,0.35,0.45,0.35,,,,,,,,,,,,,, -Fixed Window 2.30/0.40/0.31,SimpleGlazing,,,,,,,,,,,0.4,0.4,0.31,,,,,,,,,,,,,, -Fixed Window 2.56/0.45/0.35,SimpleGlazing,,,,,,,,,,,0.45,0.45,0.35,,,,,,,,,,,,,, -Fixed Window 2.62/0.30/0.21,SimpleGlazing,,,,,,,,,,,0.459978667,0.3,0.21,,,,,,,,,,,,,, -Fixed Window 2.67/0.30/0.21,SimpleGlazing,,,,,,,,,,,0.469978203,0.49,0.38,,,,,,,,,,,,,, -Fixed Window 2.96/0.39/0.31,SimpleGlazing,,,,,,,,,,,0.519975884,0.39,0.31,,,,,,,,,,,,,, -Fixed Window 2.96/0.49/0.41,SimpleGlazing,,,,,,,,,,,0.519975884,0.49,0.41,,,,,,,,,,,,,, -Fixed Window 2.96/0.62/0.54,SimpleGlazing,,,,,,,,,,,0.519975884,0.62,0.54,,,,,,,,,,,,,, -Fixed Window 3.12/0.40/0.31,SimpleGlazing,,,,,,,,,,,0.55,0.4,0.31,,,,,,,,,,,,,, -Fixed Window 3.24/0.25/0.16,SimpleGlazing,,,,,,,,,,,0.569973565,0.25,0.16,,,,,,,,,,,,,, -Fixed Window 3.24/0.39/0.31,SimpleGlazing,,,,,,,,,,,0.569973565,0.39,0.31,,,,,,,,,,,,,, -Fixed Window 3.24/0.49/0.41,SimpleGlazing,,,,,,,,,,,0.569973565,0.49,0.41,,,,,,,,,,,,,, -Fixed Window 3.35/0.36/0.27,SimpleGlazing,,,,,,,,,,,0.589972638,0.36,0.27,,,,,,,,,,,,,, -Fixed Window 3.35/0.39/0.31,SimpleGlazing,,,,,,,,,,,0.589972638,0.39,0.31,,,,,,,,,,,,,, -Fixed Window 3.53/0.41/0.32,SimpleGlazing,,,,,,,,,,,0.619971246,0.41,0.32,,,,,,,,,,,,,, -Fixed Window 3.69/0.25/0.16,SimpleGlazing,,,,,,,,,,,0.65,0.25,0.16,,,,,,,,,,,,,, -Fixed Window 3.69/0.70/0.60,SimpleGlazing,,,,,,,,,,,0.65,0.7,0.6,,,,,,,,,,,,,, -Fixed Window 3.81/0.39/0.27,SimpleGlazing,,,,,,,,,,,0.519975884,0.39,0.27,,,,,,,,,,,,,, -Fixed Window 3.81/0.49/0.38,SimpleGlazing,,,,,,,,,,,0.519975884,0.49,0.38,,,,,,,,,,,,,, -Fixed Window 4.09/0.26/0.13,SimpleGlazing,,,,,,,,,,,0.719966609,0.25,0.13,,,,,,,,,,,,,, -Fixed Window 4.09/0.36/0.23,SimpleGlazing,,,,,,,,,,,0.719966609,0.36,0.23,,,,,,,,,,,,,, -Fixed Window 4.09/0.39/0.25,SimpleGlazing,,,,,,,,,,,0.719966609,0.39,0.25,,,,,,,,,,,,,, -Fixed Window 4.26/0.25/0.16,SimpleGlazing,,,,,,,,,,,0.75,0.25,0.16,,,,,,,,,,,,,, -Fixed Window 5.84/0.25/0.11,SimpleGlazing,,,,,,,,,,,1.028483473,0.25,0.11,,,,,,,,,,,,,, -Fixed Window 5.84/0.39/0.22,SimpleGlazing,,,,,,,,,,,1.028483473,0.39,0.22,,,,,,,,,,,,,, -Fixed Window 5.84/0.44/0.27,SimpleGlazing,,,,,,,,,,,1.028483473,0.44,0.27,,,,,,,,,,,,,, -Fixed Window 5.84/0.54/0.38,SimpleGlazing,,,,,,,,,,,1.028483473,0.54,0.38,,,,,,,,,,,,,, -Fixed Window 5.84/0.61/0.47,SimpleGlazing,,,,,,,,,,,1.028483473,0.61,0.47,,,,,,,,,,,,,, -Fixed Window 5.84/0.70/0.60,SimpleGlazing,,,,,,,,,,,1.028483473,0.7,0.6,,,,,,,,,,,,,, -G01 13mm gypsum board,StandardOpaqueMaterial,Smooth,0.5,1.10957004,0.450625001,49.9424,0.260516252,0.9,0.7,0.5,,,,,,,,,,,,,,,,,, -G01a 19mm gypsum board,StandardOpaqueMaterial,MediumSmooth,0.748031496,1.109355488,0.674293772,49.94236846,0.260342027,0.9,0.4,0.4,,,,,,,,,,,,,,,,,, -G05 25mm wood,StandardOpaqueMaterial,MediumSmooth,1,1.04002077,0.961519259,37.95620003,0.389318812,0.9,0.5,0.5,,,,,,,,,,,,,,,,,, -Gap_1_W_0_0018,Gas,,0.070866142,,,,,,,,Air,,,,,,,,,,,,,,,,, -Gap_1_W_0_0024,Gas,,0.094488189,,,,,,,,Air,,,,,,,,,,,,,,,,, -Gap_1_W_0_0025,Gas,,0.098425197,,,,,,,,Air,,,,,,,,,,,,,,,,, -Gap_1_W_0_0032,Gas,,0.125984252,,,,,,,,Air,,,,,,,,,,,,,,,,, -Gap_1_W_0_0038,Gas,,0.149606299,,,,,,,,Air,,,,,,,,,,,,,,,,, -Gap_1_W_0_0042,Gas,,0.165354331,,,,,,,,Air,,,,,,,,,,,,,,,,, -Gap_1_W_0_0043,Gas,,0.169291339,,,,,,,,Air,,,,,,,,,,,,,,,,, -Glass fiber batt - 10 in. R30 (CEC Default),StandardOpaqueMaterial,MediumRough,10,0.3336,29.97601918,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass fiber batt - 12 in. R38 (CEC Default),StandardOpaqueMaterial,MediumRough,12,0.3156,38.02281369,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass fiber batt - 3 1/2 in. R11 (CEC Default),StandardOpaqueMaterial,MediumRough,3.5,0.318,11.00628931,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass fiber batt - 3 1/2 in. R13 (CEC Default),StandardOpaqueMaterial,MediumRough,3.5,0.2688,13.02083333,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass fiber batt - 3 1/2 in. R15 (CEC Default),StandardOpaqueMaterial,MediumRough,3.5,0.2328,15.03436426,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass fiber batt - 4 1/2 in.,StandardOpaqueMaterial,MediumRough,4.5,0.3,15,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass fiber batt - 4 in.,StandardOpaqueMaterial,MediumRough,4,0.3,13.33333333,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass fiber batt - 5 1/2 in. R19 (CEC Default),StandardOpaqueMaterial,MediumRough,5.5,0.306,17.97385621,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass fiber batt - 5 1/2 in. R21 (CEC Default),StandardOpaqueMaterial,MediumRough,5.5,0.2616,21.02446483,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass fiber batt - 5 in.,StandardOpaqueMaterial,MediumRough,5,0.3,16.66666667,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass fiber batt - 6 1/2 in.,StandardOpaqueMaterial,MediumRough,6.5,0.3,21.66666667,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass fiber batt - 6 in.,StandardOpaqueMaterial,MediumRough,6,0.3,20,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass fiber batt - 7 1/4 in. R25 (CEC Default),StandardOpaqueMaterial,MediumRough,7.25,0.3024,23.97486772,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass fiber batt - 7 1/4 in. R30 (CEC Default),StandardOpaqueMaterial,MediumRough,7.25,0.2904,24.96556474,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass fiber batt - 8 1/4 in. R30C (CEC Default),StandardOpaqueMaterial,MediumRough,8.25,0.2748,30.02183406,0.7,0.2,,,,,,,,,,,,,,,,,,,,, -Glass_2010F_LayerAvg,StandardGlazing,,0.087007874,6.933471799,0.144227889,,,,,,,,,,SpectralAverage,0.434294,0.4183747,0.3410654,0.797579,0.043577,0.056031,0,0.042274,0.84,1,FALSE,, -Glass_2022F_LayerAvg,StandardGlazing,,0.153543307,6.933471799,0.144227889,,,,,,,,,,SpectralAverage,0.355897,0.3940945,0.2656452,0.677694,0.042734,0.05547,0,0.046,0.84,1,FALSE,, -Glass_2027F_LayerAvg,StandardGlazing,,0.157480315,6.933471799,,,,,,,,,,,SpectralAverage,0.369744,0.4700695,0.340935,0.765222,0.0546,0.073741,0,0.03675,0.84,1,FALSE,, -Glass_2052_LayerAvg,StandardGlazing,,0.329527559,6.933471799,,,,,,,,,,,SpectralAverage,0.507767,0.05422805,0.05449309,0.586833,0.05805,0.058397,0,0.84,0.84,1,FALSE,, -Glass_2175_LayerAvg,StandardGlazing,,0.338582677,6.933471799,0.144227889,,,,,,,,,,SpectralAverage,0.167758,0.2176064,0.4379779,0.416044,0.078729,0.10654,0,0.84,0.84,1,FALSE,, -GREEN 3MM,StandardGlazing,,0.118110236,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.635,0.063,0.063,0.822,0.075,0.075,0,0.84,0.84,1,FALSE,, -GREEN 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.487,0.056,0.056,0.749,0.07,0.07,0,0.84,0.84,1,FALSE,, -GREY 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.455,0.053,0.053,0.431,0.052,0.052,0,0.84,0.84,1,FALSE,, -Ground_Floor_R11_T2013,StandardOpaqueMaterial,Smooth,1.74123,0.15963,10.91,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -Ground_Floor_R17_T2013,StandardOpaqueMaterial,Smooth,2.71324,0.15963,17.66,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -Ground_Floor_R22_T2013,StandardOpaqueMaterial,Smooth,3.51125,0.15963,22.47,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -Gypsum Board - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,1.10004,0.454528926,40,0.27,,,,,,,,,,,,,,,,,,,,, -Gypsum Board - 1/2 in. CBES,StandardOpaqueMaterial,Smooth,0.5,1.1101,,40,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -Gypsum Board - 3/4 in.,StandardOpaqueMaterial,MediumSmooth,0.75,1.10004,0.681793389,40,0.27,,,,,,,,,,,,,,,,,,,,, -Gypsum Board - 3/8 in.,StandardOpaqueMaterial,MediumSmooth,0.38,1.10004,0.345441984,40,0.27,,,,,,,,,,,,,,,,,,,,, -Gypsum Board - 5/8 in.,StandardOpaqueMaterial,MediumSmooth,0.63,1.10004,0.572706447,40,0.27,,,,,,,,,,,,,,,,,,,,, -Gypsum Or Plaster Board - 3/8 in.,StandardOpaqueMaterial,MediumSmooth,0.374015748,4.021413643,0.093006037,49.94236846,0.260342027,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Gypsum partition block - 3 cells - 4 in. x 12 in. x 30 in. - 4 in.,StandardOpaqueMaterial,MediumRough,4,2.4,1.666666667,53.1,0.19,,,,,,,,,,,,,,,,,,,,, -Gypsum partition block - 4 cells - 3 in. x 12 in. x 30 in. - 3 in.,StandardOpaqueMaterial,MediumRough,3,2.22,1.351351351,53.1,0.19,,,,,,,,,,,,,,,,,,,,, -Gypsum partition block - solid - 3 in. x 12 in. x 30 in. - 3 in.,StandardOpaqueMaterial,MediumRough,3,2.3796,1.260716087,62.4,0.19,,,,,,,,,,,,,,,,,,,,, -Gypsum plaster - 80 lb/ft3 - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,3.2004,0.156230471,80,0.26,,,,,,,,,,,,,,,,,,,,, -Gypsum plaster - 80 lb/ft3 - 5/8 in.,StandardOpaqueMaterial,Smooth,0.63,3.2004,0.196850394,80,0.26,,,,,,,,,,,,,,,,,,,,, -Gypsum plaster - on metal lath 70 lb/ft3 - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,2.6004,0.288417167,70,0.26,,,,,,,,,,,,,,,,,,,,, -Gypsum plaster - on metal lath 80 lb/ft3 - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,3.2004,0.234345707,80,0.26,,,,,,,,,,,,,,,,,,,,, -Hard Board - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,0.72,1.041666667,50,0.31,,,,,,,,,,,,,,,,,,,,, -Hardboard - HDF - 50 lb/ft3 - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.7296,0.685307018,50,0.31,,,,,,,,,,,,,,,,,,,,, -Hardboard - HDF - 50 lb/ft3 - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,0.7296,1.027960526,50,0.31,,,,,,,,,,,,,,,,,,,,, -Hardboard - HDF - 50 lb/ft3 - 3/8 in.,StandardOpaqueMaterial,Smooth,0.38,0.7296,0.520833333,50,0.31,,,,,,,,,,,,,,,,,,,,, -Hardboard - HDF - 50 lb/ft3 - 5/8 in.,StandardOpaqueMaterial,Smooth,0.63,0.7296,0.863,50,0.31,,,,,,,,,,,,,,,,,,,,, -Hardwood - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,1.1604,0.861771803,42.43,0.39,,,,,,,,,,,,,,,,,,,,, -Hardwood - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,1.1604,0.430885901,42.43,0.39,,,,,,,,,,,,,,,,,,,,, -Hardwood - 3/4 in.,StandardOpaqueMaterial,MediumSmooth,0.75,1.1604,0.646328852,42.43,0.39,,,,,,,,,,,,,,,,,,,,, -HB Part. Brd - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,1.17996,0.635614767,50,0.31,,,,,,,,,,,,,,,,,,,,, -HW CONCRETE,StandardOpaqueMaterial,Rough,4,9.09153953,0.439969489,139.83872,0.2,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -HW CONCRETE 8 in,StandardOpaqueMaterial,Rough,8,9.09153953,0.879938978,139.83872,0.2,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -I01 25mm insulation board,StandardOpaqueMaterial,MediumRough,1,0.208004154,4.807596295,2.684402305,0.289003535,0.9,0.6,0.6,,,,,,,,,,,,,,,,,, -I02 50mm insulation board,StandardOpaqueMaterial,MediumRough,2,0.208004154,9.615192591,2.684402305,0.289003535,0.9,0.6,0.6,,,,,,,,,,,,,,,,,, -IEAD NonRes Roof Insulation-1.76,StandardOpaqueMaterial,MediumRough,2.912618228,0.339740118,8.573077103,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -IEAD Roof Insulation R-3.47 IP,StandardOpaqueMaterial,MediumRough,1.178836998,0.339740118,3.469819827,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 1 1/2 in. Polyurethane Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,9,0.4704,19.13265306,100.33,0.23,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 1 1/2 in. Polyurethane Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,11,0.57,19.29824561,109.36,0.22,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 2 1/2 in. EPS Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,11,0.51648,21.29801735,76.81,0.23,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 2 1/2 in. EPS Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,13,0.60612,21.44789811,86.54,0.22,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 2 in. EPS Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,10,0.6096,16.40419948,90.4,0.23,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 2 in. EPS Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,12,0.72,16.66666667,100.33,0.22,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 2 in. Polyurethane Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,10,0.4404,22.70663034,90.4,0.23,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 2 in. Polyurethane Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,12,0.5196,23.09468822,100.33,0.22,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 2 in. XPS Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,10,0.4704,21.2585034,90.4,0.23,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 2 in. XPS Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,12,0.57,21.05263158,100.33,0.22,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 3 in. EPS Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,12,0.5004,23.98081535,75.5,0.23,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 3 in. EPS Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,14,0.57,24.56140351,86.14,0.22,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 3 in. XPS Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,12,0.39,30.76923077,75.5,0.23,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 3 in. XPS Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,14,0.45,31.11111111,86.14,0.22,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 4 1/2 in. Polyurethane Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,15,0.3504,42.80821918,60.6,0.23,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 4 1/2 in. Polyurethane Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,17,0.3996,42.54254254,71.12,0.22,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 4 in. EPS Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,14,0.4296,32.58845438,64.86,0.23,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 4 in. EPS Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,16,0.5004,31.97442046,75.5,0.22,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 4 in. XPS Ins. each side - concrete 6 in.,StandardOpaqueMaterial,Smooth,14,0.3504,39.9543379,64.86,0.23,,,,,,,,,,,,,,,,,,,,, -Insulating Concrete Forms - 4 in. XPS Ins. each side - concrete 8 in.,StandardOpaqueMaterial,Smooth,16,0.39,41.02564103,75.5,0.22,,,,,,,,,,,,,,,,,,,,, -Insulation 1m,StandardOpaqueMaterial,Smooth,39.37,0.13876,,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -Interior Wall Addi Insul,StandardOpaqueMaterial,MediumRough,1e-06,0.299941999,3.33e-06,1.399999086,0.199866248,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Light Roof - 2/5 in.,StandardOpaqueMaterial,VeryRough,0.2,2.4012,0.083291687,120,0.2,,,,,,,,,,,,,,,,,,,,, -Linoleum/cork tile - 1/4 in.,StandardOpaqueMaterial,MediumRough,0.25,0.51,0.490196078,29,0.45,,,,,,,,,,,,,,,,,,,,, -LoE CLEAR 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.6,0.17,0.22,0.84,0.055,0.078,0,0.84,0.1,1,FALSE,, -LoE SPEC SEL CLEAR 3MM,StandardGlazing,,0.118110236,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.45,0.34,0.37,0.78,0.07,0.06,0,0.84,0.03,1,FALSE,, -LoE SPEC SEL CLEAR 6MM Rev,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.43,0.42,0.3,0.77,0.06,0.07,0,0.03,0.84,1,FALSE,, -LoE SPEC SEL TINT 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.26,0.14,0.41,0.46,0.06,0.04,0,0.84,0.03,1,FALSE,, -LoE TINT 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.36,0.093,0.2,0.5,0.035,0.054,0,0.84,0.1,1,FALSE,, -Loose fill - Mineral fiber - 2 lb/ft3 - 13 3/4 in.,StandardOpaqueMaterial,Rough,13.75,0.336,40.92261905,2,0.2,,,,,,,,,,,,,,,,,,,,, -Loose fill - Mineral fiber - 2 lb/ft3 - 4 in.,StandardOpaqueMaterial,Rough,4,0.336,11.9047619,2,0.2,,,,,,,,,,,,,,,,,,,,, -Loose fill - Mineral fiber - 2 lb/ft3 - 6 1/2 in.,StandardOpaqueMaterial,Rough,6.5,0.336,19.3452381,2,0.2,,,,,,,,,,,,,,,,,,,,, -Loose fill - Mineral fiber - 2 lb/ft3 - 7 1/2 in.,StandardOpaqueMaterial,Rough,7.5,0.336,22.32142857,2,0.2,,,,,,,,,,,,,,,,,,,,, -Loose fill - Mineral fiber - 2 lb/ft3 - 8 1/4 in.,StandardOpaqueMaterial,Rough,8.25,0.336,24.55357143,2,0.2,,,,,,,,,,,,,,,,,,,,, -Loose fill - Mineral fiber - closed sidewalls - 3 1/2 in.,StandardOpaqueMaterial,Rough,3.5,0.336,10.41666667,2,0.2,,,,,,,,,,,,,,,,,,,,, -M01 100mm brick,StandardOpaqueMaterial,MediumRough,4,6.170789901,0.648215231,119.8616843,0.188688258,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -M11 100mm lightweight concrete,StandardOpaqueMaterial,MediumRough,4,3.674740053,1.088512369,79.90778954,0.200630553,0.9,0.5,0.5,,,,,,,,,,,,,,,,,, -M15 200mm heavyweight concrete,StandardOpaqueMaterial,MediumRough,8,13.52027001,0.591704159,139.8386317,0.214961307,0.9,0.5,0.5,,,,,,,,,,,,,,,,,, -Maple - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,1.14,0.877192982,41.87,0.39,,,,,,,,,,,,,,,,,,,,, -Mass NonRes Wall Insulation-0.43,StandardOpaqueMaterial,MediumRough,0.017196119,0.339740118,0.050615509,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Mass Wall Insulation R-4.23 IP,StandardOpaqueMaterial,MediumRough,1.438471204,0.339740118,4.234033978,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Mastic asphalt (heavy - 20% grit) - 1 in.,StandardOpaqueMaterial,VeryRough,1,1.2996,0.769467528,59,0.22,,,,,,,,,,,,,,,,,,,,, -MAT-CC05 4 HW CONCRETE,StandardOpaqueMaterial,Rough,4,9.089781528,0.440054581,139.8386317,0.199866246,0.9,0.85,0.85,,,,,,,,,,,,,,,,,, -MAT-CC05 8 HW CONCRETE,StandardOpaqueMaterial,Rough,8,9.089781528,0.880109162,139.8386317,0.199866246,0.9,0.85,0.85,,,,,,,,,,,,,,,,,, -MAT-SHEATH,MasslessOpaqueMaterial,,,6.240124619,0.16025321,0.043699572,0.000167192,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Metal Building Semi-Cond Wall Insulation-0.54,StandardOpaqueMaterial,MediumRough,0.604172732,0.339740118,1.778337913,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Metal Building Wall Insulation R-4.14 IP,StandardOpaqueMaterial,MediumRough,1.404445223,0.339740118,4.133881011,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Metal Deck - 1/16 in.,StandardOpaqueMaterial,Smooth,0.0625,314.4,0.000198791,488.22,0.12,,,,,,,,,,,,,,,,,,,,, -Metal Decking,StandardOpaqueMaterial,MediumSmooth,0.059055118,312.0478318,0.00018925,479.4467372,0.099933123,0.9,0.6,0.6,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 16inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,9.383,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 16inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,10.756,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 16inOC - 2x6 - R0 ins.,MasslessOpaqueMaterial,,,,0.003,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 16inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,5.309,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 16inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,5.854,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 16inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,6.92,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 16inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,7.414,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 16inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,7.815,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 24inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,12.443,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 24inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,14.569,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 24inOC - 2x6 - R0 ins.,MasslessOpaqueMaterial,,,,0.003,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 24inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,6.576,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 24inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,7.544,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 24inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,9.037,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 24inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,9.564,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Floor - 24inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,10.336,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,10.16,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,10.92,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x12 - R30 ins.,MasslessOpaqueMaterial,,,,11.42,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,12.34,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x14 - R38 ins.,MasslessOpaqueMaterial,,,,12.97,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,6.01,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,6.52,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,6.96,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x4 - R19 ins.,MasslessOpaqueMaterial,,,,6.52,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,6.39,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,6.96,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x6 - R15 ins.,MasslessOpaqueMaterial,,,,8.16,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,8.26,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,8.68,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 16inOC - 2x8 - R21 ins.,MasslessOpaqueMaterial,,,,9.01,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,12.97,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,14.13,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x12 - R30 ins.,MasslessOpaqueMaterial,,,,14.65,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,16.44,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x14 - R38 ins.,MasslessOpaqueMaterial,,,,17.13,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,7.27,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,8.06,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,8.68,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x4 - R19 ins.,MasslessOpaqueMaterial,,,,8.06,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,7.61,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,8.36,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x6 - R15 ins.,MasslessOpaqueMaterial,,,,9.89,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,10.31,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,10.76,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Roof - 24inOC - 2x8 - R21 ins.,MasslessOpaqueMaterial,,,,11.42,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 16inOC - 2x4 - R0 ins.,MasslessOpaqueMaterial,,,,0.643,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 16inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,2.924,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 16inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,3.068,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 16inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,3.199,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 16inOC - 2x4 - R5 ins.,MasslessOpaqueMaterial,,,,1.309,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 16inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,3.924,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 16inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,4.078,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 16inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,4.558,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 16inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,4.71,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 16inOC - 2x8 - R25 ins.,MasslessOpaqueMaterial,,,,4.789,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 16inOC - 2x8 - R30 ins.,MasslessOpaqueMaterial,,,,4.829,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 24inOC - 2x4 - R0 ins.,MasslessOpaqueMaterial,,,,0.658,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 24inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,3.222,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 24inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,3.386,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 24inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,3.536,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 24inOC - 2x4 - R5 ins.,MasslessOpaqueMaterial,,,,1.463,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 24inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,4.558,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 24inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,4.671,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 24inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,4.996,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 24inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,5.171,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 24inOC - 2x8 - R25 ins.,MasslessOpaqueMaterial,,,,5.263,,,,,,,,,,,,,,,,,,,,,,, -Metal Framed Wall - 24inOC - 2x8 - R30 ins.,MasslessOpaqueMaterial,,,,5.309,,,,,,,,,,,,,,,,,,,,,,, -Metal Insulated Panels - 2 1/2 in.,StandardOpaqueMaterial,Smooth,2.5,0.16644,15.02042778,28.47,0.26,,,,,,,,,,,,,,,,,,,,, -Metal Insulated Panels - 2 in.,StandardOpaqueMaterial,Smooth,2,0.16704,11.97318008,34.87,0.26,,,,,,,,,,,,,,,,,,,,, -Metal Insulated Panels - 3 in.,StandardOpaqueMaterial,Smooth,3,0.16656,18.01152738,24.11,0.26,,,,,,,,,,,,,,,,,,,,, -Metal Insulated Panels - 4 in.,StandardOpaqueMaterial,Smooth,4,0.16992,23.54048964,18.54,0.26,,,,,,,,,,,,,,,,,,,,, -Metal Insulated Panels - 5 in.,StandardOpaqueMaterial,Smooth,5,0.1698,29.44640754,15.14,0.27,,,,,,,,,,,,,,,,,,,,, -Metal Insulated Panels - 6 in.,StandardOpaqueMaterial,Smooth,6,0.16584,36.17945007,12.84,0.27,,,,,,,,,,,,,,,,,,,,, -Metal Roof Insulation R-5.21 IP,StandardOpaqueMaterial,MediumRough,1.769246081,0.339740118,5.207645452,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Metal Roof Surface,StandardOpaqueMaterial,Smooth,0.031496063,313.947603,0.000100323,488.4363635,0.119422948,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Metal Roof Surface - Cool Roof,StandardOpaqueMaterial,Smooth,0.031496063,313.947603,0.000100323,488.4363635,0.119422948,0.75,0.37,0.7,,,,,,,,,,,,,,,,,, -Metal Roof Surface - Highly Reflective,StandardOpaqueMaterial,Smooth,0.031496063,313.947603,0.000100323,488.4363635,0.119422948,0.75,0.45,0.7,,,,,,,,,,,,,,,,,, -Metal Roofing,StandardOpaqueMaterial,MediumSmooth,0.059055118,312.0478318,0.00018925,479.4467372,0.099933123,0.9,0.6,0.6,,,,,,,,,,,,,,,,,, -Metal Roofing - Cool Roof,StandardOpaqueMaterial,MediumSmooth,0.059055118,312.0478318,0.00018925,479.4467372,0.099933123,0.75,0.37,0.6,,,,,,,,,,,,,,,,,, -Metal Roofing - Highly Reflective,StandardOpaqueMaterial,MediumSmooth,0.059055118,312.0478318,0.00018925,479.4467372,0.099933123,0.75,0.45,0.6,,,,,,,,,,,,,,,,,, -Metal Screw Down Roof - No Thrml Blk - R10 ins.,MasslessOpaqueMaterial,,,,5.756,,,,,,,,,,,,,,,,,,,,,,, -Metal Screw Down Roof - No Thrml Blk - R11 ins.,MasslessOpaqueMaterial,,,,6.414,,,,,,,,,,,,,,,,,,,,,,, -Metal Screw Down Roof - No Thrml Blk - R13ins.,MasslessOpaqueMaterial,,,,6.912,,,,,,,,,,,,,,,,,,,,,,, -Metal Screw Down Roof - No Thrml Blk - R16 ins.,MasslessOpaqueMaterial,,,,8.654,,,,,,,,,,,,,,,,,,,,,,, -Metal Screw Down Roof - No Thrml Blk - R19 ins.,MasslessOpaqueMaterial,,,,9.424,,,,,,,,,,,,,,,,,,,,,,, -Metal Semi-Cond Roof Insulation-1.05,StandardOpaqueMaterial,MediumRough,1.664068118,0.339740118,4.898061868,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Metal Siding,StandardOpaqueMaterial,Smooth,0.059055118,311.7288921,0.000189444,479.999849,0.097926818,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Metal Siding - 1/16 in.,StandardOpaqueMaterial,Smooth,0.0625,314.4,0.000198791,488.22,0.12,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam - 1/16 in.,StandardOpaqueMaterial,Smooth,0.0625,3.9996,0.015626563,488.22,0.12,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam - 1/16 in. CBES,StandardOpaqueMaterial,MediumRough,0.06,4.0241,,488.22,0.12,0.85,0.37,0.85,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R10 + R10 Ins.,MasslessOpaqueMaterial,,,,15.093,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R10 + R11 Ins.,MasslessOpaqueMaterial,,,,15.613,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R10 + R13 Ins.,MasslessOpaqueMaterial,,,,16.461,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R10 + R19 Ins.,MasslessOpaqueMaterial,,,,18.451,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R11 + R11 Ins.,MasslessOpaqueMaterial,,,,15.887,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R11 + R13 Ins.,MasslessOpaqueMaterial,,,,16.764,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R11 + R19 Ins.,MasslessOpaqueMaterial,,,,18.828,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R13 + R13 Ins.,MasslessOpaqueMaterial,,,,17.402,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R13 + R19 Ins.,MasslessOpaqueMaterial,,,,19.628,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R16 + R19 Ins.,MasslessOpaqueMaterial,,,,20.497,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - Dbl Ins. Layer - R19 + R19 Ins.,MasslessOpaqueMaterial,,,,20.959,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - Ins. and Filled Cavity - R19 + R10 Ins.,MasslessOpaqueMaterial,,,,23.61,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - R10 ins.,MasslessOpaqueMaterial,,,,9.529,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - R11 ins.,MasslessOpaqueMaterial,,,,10.09,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - R13 ins.,MasslessOpaqueMaterial,,,,11.268,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - R16 ins.,MasslessOpaqueMaterial,,,,13.109,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - R19 ins.,MasslessOpaqueMaterial,,,,14.605,,,,,,,,,,,,,,,,,,,,,,, -Metal Standing Seam Roof - Thrml Blk - R6 ins.,MasslessOpaqueMaterial,,,,5.208,,,,,,,,,,,,,,,,,,,,,,, -Metal Surface,StandardOpaqueMaterial,Smooth,0.031496063,313.947603,0.000100323,488.4363635,0.119422948,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Mortar - Cement - 1 3/4 in.,StandardOpaqueMaterial,Smooth,1.76,5.01,0.351297405,116,0.2,,,,,,,,,,,,,,,,,,,,, -Mortar - Cement - 1 in.,StandardOpaqueMaterial,Smooth,1.01,5.0304,0.200779262,116,0.2,,,,,,,,,,,,,,,,,,,,, -NACM_Carpet 3/4in,StandardOpaqueMaterial,Smooth,0.75,0.34691,,18,0.33,0.9,0.7,0.9,,,,,,,,,,,,,,,,,, -NACM_Concrete 4in_140lb/ft3,StandardOpaqueMaterial,MediumRough,4,13.52932,,139.78,0.22,0.75,0.92,0.75,,,,,,,,,,,,,,,,,, -NACM_Gypsum Board 5/8in,StandardOpaqueMaterial,MediumRough,0.63,1.1101,,40,0.27,0.9,0.7,0.5,,,,,,,,,,,,,,,,,, -Nonres_Floor_Insulation,MasslessOpaqueMaterial,MediumSmooth,,,16.3699766,,,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Oak - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,1.1796,0.847744998,43.93,0.39,,,,,,,,,,,,,,,,,,,,, -OSB - Oriented Strand Board - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,0.6204,0.805931657,41,0.45,,,,,,,,,,,,,,,,,,,,, -OSB - Oriented Strand Board - 3/4 in.,StandardOpaqueMaterial,MediumSmooth,0.75,0.9096,0.824538259,41,0.45,,,,,,,,,,,,,,,,,,,,, -OSB - Oriented Strand Board - 5/8 in.,StandardOpaqueMaterial,MediumSmooth,0.63,0.7596,0.829383886,41,0.45,,,,,,,,,,,,,,,,,,,,, -Perlite board - 1 1/2 in. R3.8,StandardOpaqueMaterial,Rough,1.5,0.3996,3.753753754,10,0.2,,,,,,,,,,,,,,,,,,,,, -Perlite board - 1 in. R2.5,StandardOpaqueMaterial,Rough,1,0.3996,2.502502503,10,0.2,,,,,,,,,,,,,,,,,,,,, -Perlite board - 2 in. R5.0,StandardOpaqueMaterial,Rough,2,0.3996,5.005005005,10,0.2,,,,,,,,,,,,,,,,,,,,, -Perlite board - 3/4 in. R1.9,StandardOpaqueMaterial,Rough,0.75,0.3996,1.876876877,10,0.2,,,,,,,,,,,,,,,,,,,,, -Perlite plaster - 25 lb/ft3 - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.6,0.833333333,25,0.32,,,,,,,,,,,,,,,,,,,,, -Perlite plaster - 38 lb/ft3 - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,1.2996,0.384733764,38,0.32,,,,,,,,,,,,,,,,,,,,, -Pine (oven-dried) - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,0.6396,1.563477173,23,0.45,,,,,,,,,,,,,,,,,,,,, -Plaster/Sand Aggregate - 1 in.,StandardOpaqueMaterial,Smooth,1.01,5.0304,0.200779262,116,0.2,,,,,,,,,,,,,,,,,,,,, -Plywood - 1 1/2 in.,StandardOpaqueMaterial,MediumSmooth,1.5,0.8004,1.874062969,30,0.45,,,,,,,,,,,,,,,,,,,,, -Plywood - 1 1/4 in.,StandardOpaqueMaterial,MediumSmooth,1.25,0.8004,1.56171914,30,0.45,,,,,,,,,,,,,,,,,,,,, -Plywood - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,0.8004,1.249375312,30,0.45,,,,,,,,,,,,,,,,,,,,, -Plywood - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,0.8004,0.624687656,30,0.45,,,,,,,,,,,,,,,,,,,,, -Plywood - 1/4 in.,StandardOpaqueMaterial,MediumSmooth,0.25,0.8004,0.312343828,30,0.45,,,,,,,,,,,,,,,,,,,,, -Plywood - 3/4 in.,StandardOpaqueMaterial,MediumSmooth,0.75,0.8004,0.937031484,30,0.45,,,,,,,,,,,,,,,,,,,,, -Plywood - 3/8 in.,StandardOpaqueMaterial,MediumSmooth,0.38,0.8004,0.474762619,30,0.45,,,,,,,,,,,,,,,,,,,,, -Plywood - 5/8 in.,StandardOpaqueMaterial,MediumSmooth,0.63,0.8004,0.787106447,30,0.45,,,,,,,,,,,,,,,,,,,,, -Plywood - 5/8 in. CBES,StandardOpaqueMaterial,Smooth,0.63,0.83257,,30,0.45,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Pulpboard or paper plaster - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,0.5004,0.999200639,38,0.32,,,,,,,,,,,,,,,,,,,,, -PYR B CLEAR 3MM,StandardGlazing,,0.118110236,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.74,0.09,0.1,0.82,0.11,0.12,0,0.84,0.2,1,FALSE,, -PYR B CLEAR 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.68,0.09,0.1,0.81,0.11,0.12,0,0.84,0.2,1,FALSE,, -R_R30,StandardOpaqueMaterial,Smooth,4.78807,0.15963,30,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -R_R38,StandardOpaqueMaterial,Smooth,6.06489,0.15963,38,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -R_T24_2013_24.86,StandardOpaqueMaterial,Smooth,3.96771,0.15963,24.86,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -R-24 Batt Wall - 8 in. R24,StandardOpaqueMaterial,VeryRough,8,0.3336,23.98081535,1.19,0.23,,,,,,,,,,,,,,,,,,,,, -R1_R14.20,StandardOpaqueMaterial,Smooth,2.26635,0.15963,14.2,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -R2_R12.90,StandardOpaqueMaterial,Smooth,2.05887,0.15963,12.9,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -R3_R17.74,StandardOpaqueMaterial,Smooth,2.83134,0.15963,17.74,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -R4_R20.28,StandardOpaqueMaterial,Smooth,3.23667,0.15963,20.28,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -Rammed Earth,StandardOpaqueMaterial,Rough,18,1.4796,12.16545012,115,0.2,,,,,,,,,,,,,,,,,,,,, -REF A CLEAR LO 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.066,0.341,0.493,0.08,0.41,0.37,0,0.84,0.4,1,FALSE,, -REF A CLEAR MID 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.11,0.27,0.43,0.14,0.31,0.35,0,0.84,0.47,1,FALSE,, -REF A TINT MID 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.06,0.13,0.42,0.09,0.14,0.35,0,0.84,0.47,1,FALSE,, -REF B CLEAR HI 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.24,0.16,0.32,0.3,0.16,0.29,0,0.84,0.6,1,FALSE,, -REF B CLEAR LO 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.15,0.22,0.38,0.2,0.23,0.33,0,0.84,0.58,1,FALSE,, -REF B TINT HI 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.15,0.09,0.33,0.18,0.08,0.28,0,0.84,0.6,1,FALSE,, -REF B TINT MID 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.1,0.11,0.41,0.13,0.1,0.32,0,0.84,0.45,1,FALSE,, -REF C CLEAR HI 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.2,0.16,0.39,0.22,0.17,0.35,0,0.84,0.55,1,FALSE,, -REF C CLEAR MID 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.17,0.2,0.42,0.19,0.21,0.38,0,0.84,0.51,1,FALSE,, -REF D CLEAR 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.429,0.308,0.379,0.334,0.453,0.505,0,0.84,0.82,1,FALSE,, -REF D TINT 6MM,StandardGlazing,,0.236220472,6.240124619,0.16025321,,,,,,,,,,SpectralAverage,0.3,0.14,0.36,0.25,0.18,0.45,0,0.84,0.82,1,FALSE,, -Roof Gravel - 1 in.,StandardOpaqueMaterial,VeryRough,1,9.9996,0.100004,159.74,0.19,,,,,,,,,,,,,,,,,,,,, -Roof Gravel - 1/2 in.,StandardOpaqueMaterial,VeryRough,0.5,9.9996,0.050002,159.74,0.19,,,,,,,,,,,,,,,,,,,,, -Roof Insulation [18],StandardOpaqueMaterial,MediumRough,6.665354331,0.339740118,19.61897926,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Roof Membrane,StandardOpaqueMaterial,VeryRough,0.374015748,1.109355488,0.337146886,69.99984791,0.348715009,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Roof Membrane - Cool Roof,StandardOpaqueMaterial,VeryRough,0.374015748,1.109355488,0.337146886,69.99984791,0.348715009,0.75,0.37,0.7,,,,,,,,,,,,,,,,,, -Roof Membrane - Highly Reflective,StandardOpaqueMaterial,VeryRough,0.374015748,1.109355488,0.337146886,69.99984791,0.348715009,0.75,0.45,0.7,,,,,,,,,,,,,,,,,, -Roofing felt - 1/8 in.,StandardOpaqueMaterial,VeryRough,0.13,8.3004,0.015661896,141,0.3,,,,,,,,,,,,,,,,,,,,, -Rubber tile - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,0.3396,2.944640754,119,0.48,,,,,,,,,,,,,,,,,,,,, -Sand aggregate - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,5.4504,0.091736386,105,0.2,,,,,,,,,,,,,,,,,,,,, -Sand aggregate - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,5.0796,0.147649421,116,0.2,,,,,,,,,,,,,,,,,,,,, -Sand aggregate - 3/8 in.,StandardOpaqueMaterial,Smooth,0.38,5.1504,0.073780677,116,0.2,,,,,,,,,,,,,,,,,,,,, -Sand aggregate - 5/8 in.,StandardOpaqueMaterial,Smooth,0.63,5.6004,0.112491965,105,0.2,,,,,,,,,,,,,,,,,,,,, -Sand aggregate on metal lath - 3/4 in.,StandardOpaqueMaterial,Smooth,0.75,5.7696,0.129991681,105,0.2,,,,,,,,,,,,,,,,,,,,, -Shingles - Asbestos cement - lapped - 1/4 in.,StandardOpaqueMaterial,VeryRough,0.25,1.1904,0.210013441,120,0.24,,,,,,,,,,,,,,,,,,,,, -Shingles - Asphalt roll siding - 1/4 in.,StandardOpaqueMaterial,VeryRough,0.25,1.6704,0.149664751,70,0.36,,,,,,,,,,,,,,,,,,,,, -Shingles - Wood - 16 in. - 7 1/2 in. exposure - 1/2 in.,StandardOpaqueMaterial,MediumRough,0.5,0.57,0.877192982,22,0.31,,,,,,,,,,,,,,,,,,,,, -Shingles - Wood - plus insulated backer board Siding - 5/16 in.,StandardOpaqueMaterial,MediumRough,0.31,0.2196,1.411657559,22,0.31,,,,,,,,,,,,,,,,,,,,, -Siding - Asphalt insulating siding - 1/2 in. bed - 1/2 in.,StandardOpaqueMaterial,VeryRough,0.5,0.3396,1.472320377,70,0.35,,,,,,,,,,,,,,,,,,,,, -Siding - Wood - bevel - 10 in. - lapped - 3/4 in.,StandardOpaqueMaterial,Rough,0.75,0.7104,1.055743243,22,0.28,,,,,,,,,,,,,,,,,,,,, -Simple Glazing,SimpleGlazing,,,,,,,,,,,1.23,0.61,0.25,,,,,,,,,,,,,, -SIPS - Crawl Space - R22 - Double 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.24768,26.24354005,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - Crawl Space - R22 - I Joist Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.23148,28.08017971,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - Crawl Space - R22 - Single 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.23952,27.13760855,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - Crawl Space - R28 - Double 2x Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.25356,32.53667771,5.85,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - Crawl Space - R28 - I Joist Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.2436,33.86699507,5.85,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - Crawl Space - R28 - Single 2x Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.2436,33.86699507,5.85,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - Crawl Space - R33 - Double 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.1842,35.28773073,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - Crawl Space - R33 - I Joist Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.16884,38.49798626,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - Crawl Space - R33 - Single 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.16884,38.49798626,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - Crawl Space - R36 - Double 2x Spline - 10 1/4 in.,StandardOpaqueMaterial,Smooth,10.25,0.26628,38.49331531,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - Crawl Space - R36 - I Joist Spline - 10 1/4 in.,StandardOpaqueMaterial,Smooth,10.25,0.2424,42.28547855,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - Crawl Space - R36 - Single 2x Spline - 10 1/4 in.,StandardOpaqueMaterial,Smooth,10.25,0.25428,40.3098946,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - No Crawl Space - R22 - Double 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.32364,20.084044,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - No Crawl Space - R22 - I Joist Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.29772,21.83259438,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - No Crawl Space - R22 - Single 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.30636,21.21686904,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - No Crawl Space - R28 - Double 2x Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.3144,26.24045802,5.85,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - No Crawl Space - R28 - I Joist Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.29376,28.08415033,5.85,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - No Crawl Space - R28 - Single 2x Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.30408,27.13101815,5.85,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - No Crawl Space - R33 - Double 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.23148,28.08017971,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - No Crawl Space - R33 - I Joist Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.19968,32.55208333,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - No Crawl Space - R33 - Single 2x Spline - 6 1/2 in.,StandardOpaqueMaterial,Smooth,6.5,0.2076,31.31021195,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - No Crawl Space - R36 - Double 2x Spline - 10 1/4 in.,StandardOpaqueMaterial,Smooth,10.25,0.315,32.53968254,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - No Crawl Space - R36 - I Joist Spline - 10 1/4 in.,StandardOpaqueMaterial,Smooth,10.25,0.2904,35.29614325,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - No Crawl Space - R36 - Single 2x Spline - 10 1/4 in.,StandardOpaqueMaterial,Smooth,10.25,0.2904,35.29614325,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R14 - Double 2x Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.39312,11.44688645,9.89,0.31,,,,,,,,,,,,,,,,,,,,, -SIPS - R14 - I joist Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.35304,12.746431,9.89,0.31,,,,,,,,,,,,,,,,,,,,, -SIPS - R14 - Metal Spline - 48 in.,StandardOpaqueMaterial,Smooth,48,4.14,11.5942029,1.83,0.27,,,,,,,,,,,,,,,,,,,,, -SIPS - R14 - OSB Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.303,14.85148515,9.89,0.31,,,,,,,,,,,,,,,,,,,,, -SIPS - R14 - Single 2x Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.35868,12.54600201,9.89,0.31,,,,,,,,,,,,,,,,,,,,, -SIPS - R18 - Double 2x Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.3306,13.61161525,9.89,0.31,,,,,,,,,,,,,,,,,,,,, -SIPS - R18 - I joist Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.29208,15.40673788,9.89,0.31,,,,,,,,,,,,,,,,,,,,, -SIPS - R18 - OSB Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.25968,17.32902033,9.89,0.31,,,,,,,,,,,,,,,,,,,,, -SIPS - R18 - Single 2x Spline - 4 1/2 in.,StandardOpaqueMaterial,Smooth,4.5,0.303,14.85148515,9.89,0.31,,,,,,,,,,,,,,,,,,,,, -SIPS - R22 - Double 2x Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.32496,20.00246184,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R22 - Double 2x Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.3828,16.98014629,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R22 - I joist Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.30216,21.51178184,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R22 - I joist Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.33696,19.29012346,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R22 - Metal Spline - 48 in.,StandardOpaqueMaterial,Smooth,48,3.0396,15.79155152,1.83,0.27,,,,,,,,,,,,,,,,,,,,, -SIPS - R22 - OSB Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.28692,22.65439844,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R22 - OSB Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.28452,22.84549417,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R22 - Single 2x Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.3096,20.99483204,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R22 - Single 2x Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.35208,18.46171325,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R28 - Double 2x Spline - 8 1/2 in.,StandardOpaqueMaterial,Smooth,8.5,0.33612,25.28858741,5.71,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R28 - Double 2x Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.37992,21.71509792,5.85,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R28 - I joist Spline - 8 1/2 in.,StandardOpaqueMaterial,Smooth,8.5,0.2976,28.56182796,5.71,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R28 - I joist Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.32364,25.49128661,5.85,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R28 - Metal Spline - 48 in.,StandardOpaqueMaterial,Smooth,48,2.45688,19.53697372,1.83,0.27,,,,,,,,,,,,,,,,,,,,, -SIPS - R28 - OSB Spline - 8 1/2 in.,StandardOpaqueMaterial,Smooth,8.5,0.2976,28.56182796,5.71,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R28 - OSB Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.27768,29.71045808,5.85,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R28 - Single 2x Spline - 8 1/2 in.,StandardOpaqueMaterial,Smooth,8.5,0.3072,27.66927083,5.71,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R28 - Single 2x Spline - 8 1/4 in.,StandardOpaqueMaterial,Smooth,8.25,0.34236,24.09744129,5.85,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R33 - Double 2x Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.23484,27.67841935,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R33 - Double 2x Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.29928,21.71879177,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R33 - I joist Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.213,30.51643192,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R33 - I joist Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.24768,26.24354005,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R33 - OSB Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.2058,31.5840622,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R33 - OSB Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.21876,29.71292741,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R33 - Single 2x Spline - 6 1/2 in. (Roof),StandardOpaqueMaterial,Smooth,6.5,0.213,30.51643192,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R33 - Single 2x Spline - 6 1/2 in. (Wall),StandardOpaqueMaterial,Smooth,6.5,0.26232,24.778896,7.15,0.3,,,,,,,,,,,,,,,,,,,,, -SIPS - R36 - Double 2x Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.31308,32.73923598,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R36 - Double 2x Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.3792,27.03059072,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R36 - I joist Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.2904,35.29614325,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R36 - I joist Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.32244,31.78885994,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R36 - Metal Spline - 48 in.,StandardOpaqueMaterial,Smooth,48,2.2296,21.5285253,1.83,0.27,,,,,,,,,,,,,,,,,,,,, -SIPS - R36 - OSB Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.27912,36.72255661,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R36 - OSB Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.27756,36.9289523,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R36 - Single 2x Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.30168,33.97639883,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R36 - Single 2x Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.345,29.71014493,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R44 - Double 2x Spline - 12 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,12.25,0.32016,38.26211894,4.27,0.28,,,,,,,,,,,,,,,,,,,,, -SIPS - R44 - Double 2x Spline - 12 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,12.25,0.35844,34.17587323,4.27,0.28,,,,,,,,,,,,,,,,,,,,, -SIPS - R44 - I joist Spline - 12 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,12.25,0.2802,43.71877231,4.27,0.28,,,,,,,,,,,,,,,,,,,,, -SIPS - R44 - I joist Spline - 12 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,12.25,0.31848,38.46395378,4.27,0.28,,,,,,,,,,,,,,,,,,,,, -SIPS - R44 - OSB Spline - 12 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,12.25,0.267,45.88014981,4.27,0.28,,,,,,,,,,,,,,,,,,,,, -SIPS - R44 - OSB Spline - 12 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,12.25,0.279,43.90681004,4.27,0.28,,,,,,,,,,,,,,,,,,,,, -SIPS - R44 - Single 2x Spline - 12 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,12.25,0.29352,41.73480512,4.27,0.28,,,,,,,,,,,,,,,,,,,,, -SIPS - R44 - Single 2x Spline - 12 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,12.25,0.34512,35.49490032,4.27,0.28,,,,,,,,,,,,,,,,,,,,, -SIPS - R55 - Double 2x Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.22344,45.8736126,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R55 - Double 2x Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.3,34.16666667,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R55 - I joist Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.19044,53.82272632,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R55 - I joist Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.2334,43.91602399,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R55 - OSB Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.17952,57.09670232,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R55 - OSB Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.21156,48.4496124,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R55 - Single 2x Spline - 10 1/4 in. (Roof),StandardOpaqueMaterial,Smooth,10.25,0.20136,50.90385379,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -SIPS - R55 - Single 2x Spline - 10 1/4 in. (Wall),StandardOpaqueMaterial,Smooth,10.25,0.25548,40.12055738,4.9,0.29,,,,,,,,,,,,,,,,,,,,, -Skylight_Frame_Width_0.000_in,,,,,0,,,,,,,,,,,,,,,,,,,,,,0, -Skylight_Frame_Width_0.334_in,,,,,0.02,,,,,,,,,,,,,,,,,,,,,,0.334, -Skylight_Frame_Width_0.430_in,,,,,0.02,,,,,,,,,,,,,,,,,,,,,,0.43, -Skylight_Frame_Width_0.709_in,,,,,0.02,,,,,,,,,,,,,,,,,,,,,,0.709, -Skylight_Frame_Width_2.339_in,,,,,0.02,,,,,,,,,,,,,,,,,,,,,,2.339, -Slate - 1/2 in.,StandardOpaqueMaterial,VeryRough,0.5,11.0304,0.045329272,119.81,0.3,,,,,,,,,,,,,,,,,,,,, -Slate or tile - 1/2 in.,StandardOpaqueMaterial,VeryRough,0.5,11.0304,0.045329272,119.81,0.3,,,,,,,,,,,,,,,,,,,,, -Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 3 1/2 in.,StandardOpaqueMaterial,Rough,3.5,0.3204,10.92384519,4.6,0.34,,,,,,,,,,,,,,,,,,,,, -Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 4 1/2 in.,StandardOpaqueMaterial,Rough,4.5,0.3204,14.04494382,4.6,0.34,,,,,,,,,,,,,,,,,,,,, -Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 4 in.,StandardOpaqueMaterial,Rough,4,0.3204,12.48439451,4.6,0.34,,,,,,,,,,,,,,,,,,,,, -Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 5 1/2 in.,StandardOpaqueMaterial,Rough,5.5,0.3204,17.16604245,4.6,0.34,,,,,,,,,,,,,,,,,,,,, -Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 5 in.,StandardOpaqueMaterial,Rough,5,0.3204,15.60549313,4.6,0.34,,,,,,,,,,,,,,,,,,,,, -Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 6 1/2 in.,StandardOpaqueMaterial,Rough,6.5,0.3204,20.28714107,4.6,0.34,,,,,,,,,,,,,,,,,,,,, -Spray applied - Cellulosic fiber - 4.6 lb/ft3 - 6 in.,StandardOpaqueMaterial,Rough,6,0.3204,18.72659176,4.6,0.34,,,,,,,,,,,,,,,,,,,,, -Spray applied - Glass fiber - 3.9 lb/ft3 - 3 1/2 in.,StandardOpaqueMaterial,MediumRough,3.5,0.27,12.96296296,3.9,0.23,,,,,,,,,,,,,,,,,,,,, -Spray applied - Glass fiber - 3.9 lb/ft3 - 4 1/2 in.,StandardOpaqueMaterial,MediumRough,4.5,0.27,16.66666667,3.9,0.23,,,,,,,,,,,,,,,,,,,,, -Spray applied - Glass fiber - 3.9 lb/ft3 - 4 in.,StandardOpaqueMaterial,MediumRough,4,0.27,14.81481481,3.9,0.23,,,,,,,,,,,,,,,,,,,,, -Spray applied - Glass fiber - 3.9 lb/ft3 - 5 1/2 in.,StandardOpaqueMaterial,MediumRough,5.5,0.27,20.37037037,3.9,0.23,,,,,,,,,,,,,,,,,,,,, -Spray applied - Glass fiber - 3.9 lb/ft3 - 5 in.,StandardOpaqueMaterial,MediumRough,5,0.27,18.51851852,3.9,0.23,,,,,,,,,,,,,,,,,,,,, -Spray applied - Glass fiber - 3.9 lb/ft3 - 6 1/2 in.,StandardOpaqueMaterial,MediumRough,6.5,0.27,24.07407407,3.9,0.23,,,,,,,,,,,,,,,,,,,,, -Spray applied - Glass fiber - 3.9 lb/ft3 - 6 in.,StandardOpaqueMaterial,MediumRough,6,0.27,22.22222222,3.9,0.23,,,,,,,,,,,,,,,,,,,,, -Spray applied - Polyurethane foam - 0.5 lb/ft3 - 3 1/2 in.,StandardOpaqueMaterial,Rough,3.5,0.3,11.66666667,0.5,0.35,,,,,,,,,,,,,,,,,,,,, -Spray applied - Polyurethane foam - 0.5 lb/ft3 - 4 1/2 in.,StandardOpaqueMaterial,Rough,4.5,0.3,15,0.5,0.35,,,,,,,,,,,,,,,,,,,,, -Spray applied - Polyurethane foam - 0.5 lb/ft3 - 4 in.,StandardOpaqueMaterial,Rough,4,0.3,13.33333333,0.5,0.35,,,,,,,,,,,,,,,,,,,,, -Spray applied - Polyurethane foam - 0.5 lb/ft3 - 5 1/2 in.,StandardOpaqueMaterial,Rough,5.5,0.3,18.33333333,0.5,0.35,,,,,,,,,,,,,,,,,,,,, -Spray applied - Polyurethane foam - 0.5 lb/ft3 - 5 in.,StandardOpaqueMaterial,Rough,5,0.3,16.66666667,0.5,0.35,,,,,,,,,,,,,,,,,,,,, -Spray applied - Polyurethane foam - 0.5 lb/ft3 - 6 1/2 in.,StandardOpaqueMaterial,Rough,6.5,0.3,21.66666667,0.5,0.35,,,,,,,,,,,,,,,,,,,,, -Spray applied - Polyurethane foam - 0.5 lb/ft3 - 6 in.,StandardOpaqueMaterial,Rough,6,0.3,20,0.5,0.35,,,,,,,,,,,,,,,,,,,,, -Spray applied - Polyurethane foam - 3.0 lb/ft3 - 3 1/2 in.,StandardOpaqueMaterial,Rough,3.5,0.20004,17.4965007,3,0.35,,,,,,,,,,,,,,,,,,,,, -Spray applied - Polyurethane foam - 3.0 lb/ft3 - 4 1/2 in.,StandardOpaqueMaterial,Rough,4.5,0.20004,22.4955009,3,0.35,,,,,,,,,,,,,,,,,,,,, -Spray applied - Polyurethane foam - 3.0 lb/ft3 - 4 in.,StandardOpaqueMaterial,Rough,4,0.20004,19.9960008,3,0.35,,,,,,,,,,,,,,,,,,,,, -Spray applied - Polyurethane foam - 3.0 lb/ft3 - 5 1/2 in.,StandardOpaqueMaterial,Rough,5.5,0.20004,27.4945011,3,0.35,,,,,,,,,,,,,,,,,,,,, -Spray applied - Polyurethane foam - 3.0 lb/ft3 - 5 in.,StandardOpaqueMaterial,Rough,5,0.20004,24.995001,3,0.35,,,,,,,,,,,,,,,,,,,,, -Spray applied - Polyurethane foam - 3.0 lb/ft3 - 6 1/2 in.,StandardOpaqueMaterial,Rough,6.5,0.20004,32.4935013,3,0.35,,,,,,,,,,,,,,,,,,,,, -Spray applied - Polyurethane foam - 3.0 lb/ft3 - 6 in.,StandardOpaqueMaterial,Rough,6,0.20004,29.9940012,3,0.35,,,,,,,,,,,,,,,,,,,,, -Std Wood 6 in.,StandardOpaqueMaterial,MediumSmooth,5.905511811,0.832016616,7.097829176,33.71109871,0.289003535,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Std Wood 6inch Furnishings,StandardOpaqueMaterial,MediumSmooth,5.91,0.83257,,33.71,0.29,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Steel Frame NonRes Wall Insulation-0.73,StandardOpaqueMaterial,MediumRough,0.79835618,0.339740118,2.34990258,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Steel Frame Wall Insulation R-1.02 IP,StandardOpaqueMaterial,MediumRough,0.347890885,0.339740118,1.023991182,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Steel Frame/Cavity,StandardOpaqueMaterial,MediumRough,3.500007095,0.583217221,6.001206697,40.03997387,0.119919749,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Stone - 1 in.,StandardOpaqueMaterial,MediumRough,1,12.504,0.079974408,139.78,0.22,,,,,,,,,,,,,,,,,,,,, -Straw Bale - Int and Ext Stucco - 18 in.,StandardOpaqueMaterial,Smooth,19.5,0.6504,29.98154982,12.95,0.11,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Double glass with no low e coatings - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.81,2.802469136,29.09,0.26,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Double glass with no low e coatings - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.5304,6.165158371,20.44,0.26,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Double glass with no low e coatings - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.64764,6.901982583,15.23,0.27,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Double glass with no low e coatings - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,0.7704,7.359813084,12.22,0.27,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Double glass with no low e coatings - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,0.8904,7.715633423,10.26,0.27,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Double glass with no low e coatings - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.02,7.911764706,8.88,0.27,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Double glass with no low e coatings - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.39,4.692307692,35.69,0.26,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Double glass with no low e coatings - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.4596,5.548302872,25.92,0.26,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Single glass pane. stone. or metal pane - No Ins.,StandardOpaqueMaterial,Smooth,2.52,1.2804,1.968134958,41.9,0.26,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Single glass pane. stone. or metal pane - R10 Ins.,StandardOpaqueMaterial,Smooth,3.52,0.5904,5.962059621,30.2,0.26,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Single glass pane. stone. or metal pane - R15 Ins.,StandardOpaqueMaterial,Smooth,4.72,0.6996,6.746712407,22.79,0.26,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Single glass pane. stone. or metal pane - R20 Ins.,StandardOpaqueMaterial,Smooth,5.92,0.81324,7.27952388,18.37,0.26,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Single glass pane. stone. or metal pane - R25 Ins.,StandardOpaqueMaterial,Smooth,7.12,0.93372,7.625412329,15.45,0.27,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Single glass pane. stone. or metal pane - R30 Ins.,StandardOpaqueMaterial,Smooth,8.32,1.05,7.923809524,13.37,0.27,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Single glass pane. stone. or metal pane - R4 Ins.,StandardOpaqueMaterial,Smooth,2.08,0.48624,4.277722935,50.36,0.25,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Single glass pane. stone. or metal pane - R7 Ins.,StandardOpaqueMaterial,Smooth,2.8,0.5304,5.279034691,37.69,0.26,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Triple or low e glass - No Ins.,StandardOpaqueMaterial,Smooth,2.27,0.6504,3.490159902,29.09,0.26,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Triple or low e glass - R10 Ins.,StandardOpaqueMaterial,Smooth,3.27,0.51,6.411764706,20.44,0.26,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Triple or low e glass - R15 Ins.,StandardOpaqueMaterial,Smooth,4.47,0.63636,7.024325853,15.23,0.27,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Triple or low e glass - R20 Ins.,StandardOpaqueMaterial,Smooth,5.67,0.76476,7.414090695,12.22,0.27,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Triple or low e glass - R25 Ins.,StandardOpaqueMaterial,Smooth,6.87,0.88404,7.771141577,10.26,0.27,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Triple or low e glass - R30 Ins.,StandardOpaqueMaterial,Smooth,8.07,1.0104,7.986935867,8.88,0.27,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Triple or low e glass - R4 Ins.,StandardOpaqueMaterial,Smooth,1.83,0.36,5.083333333,35.69,0.26,,,,,,,,,,,,,,,,,,,,, -Structural Glazing - Triple or low e glass - R7 Ins.,StandardOpaqueMaterial,Smooth,2.55,0.43836,5.8171366,25.92,0.26,,,,,,,,,,,,,,,,,,,,, -Stucco - 3/8 in.,StandardOpaqueMaterial,Smooth,0.38,5.0004,0.07599392,115.81,0.2,,,,,,,,,,,,,,,,,,,,, -Stucco - 7/8 in.,StandardOpaqueMaterial,Smooth,0.88,4.86,0.181069959,115.81,0.2,,,,,,,,,,,,,,,,,,,,, -Stucco - 7/8 in. CBES,StandardOpaqueMaterial,MediumRough,0.88,4.85668,,115.81,0.2,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -Synthetic Stucco - EIFS finish - 1 in.,StandardOpaqueMaterial,Smooth,1,0.2496,4.006410256,1.5,0.35,,,,,,,,,,,,,,,,,,,,, -Terrazzo - 1 in.,StandardOpaqueMaterial,Rough,1,12.5004,0.07999744,160,0.19,,,,,,,,,,,,,,,,,,,,, -Test,Test,Test,0.1,0.1,0.1,0.1,0.1,0.1,0.1,0.1,,,,,,,,,,,,,,,,,, -Theoretical Glass [167],StandardGlazing,,0.118110236,14.61090512,0.06844203,,,,,,,,,,SpectralAverage,0.2374,0.7126,0.7126,0.2512,0.6988,0.6988,0,0.985,0.985,1,FALSE,, -Theoretical Glass [197],StandardGlazing,,0.118110236,0.28773908,3.475370816,,,,,,,,,,SpectralAverage,0.2349,0.7151,0.7151,0.2512,0.6988,0.6988,0,0.9,0.9,1,FALSE,, -Theoretical Glass [202],StandardGlazing,,0.118110236,0.133122659,7.511869212,,,,,,,,,,SpectralAverage,0.2325,0.7175,0.7175,0.3192,0.6308,0.6308,0,0.9,0.9,1,FALSE,, -Theoretical Glass [207],StandardGlazing,,0.118110236,0.092215175,10.84420217,,,,,,,,,,SpectralAverage,0.3311,0.6189,0.6189,0.44,0.51,0.51,0,0.9,0.9,1,FALSE,, -Theoretical Glass [216],StandardGlazing,,0.118110236,0.092215175,10.84420217,,,,,,,,,,SpectralAverage,0.3801,0.5699,0.5699,0.5079,0.4421,0.4421,0,0.9,0.9,1,FALSE,, -Theoretical Glass [221],StandardGlazing,,0.118110236,0.061707899,16.20538077,,,,,,,,,,SpectralAverage,0.4296,0.5204,0.5204,0.4503,0.4997,0.4997,0,0.9,0.9,1,FALSE,, -Theoretical Glass 297,StandardGlazing,,0.118110236,0.071803727,13.92685363,,,,,,,,,,SpectralAverage,0.375039,0.574961,0.574961,0.529698,0.420302,0.420302,0,0.9,0.9,1,FALSE,, -Theoretical Glass 347,StandardGlazing,,0.118110236,0.071816901,13.92429898,,,,,,,,,,SpectralAverage,0.315861,0.634139,0.634139,0.479911,0.470089,0.470089,0,0.9,0.9,1,FALSE,, -Tile Gap - 3/4 in.,StandardOpaqueMaterial,VeryRough,0.75,0.6612,1.13430127,70,0.24,,,,,,,,,,,,,,,,,,,,, -Typical Air Wall,MasslessOpaqueMaterial,,,6.240124619,0.16025321,0.043699572,0.000167192,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Typical Carpet Pad,MasslessOpaqueMaterial,VeryRough,,,1.229230374,,,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -Typical Insulation,MasslessOpaqueMaterial,MediumSmooth,,6.240124619,0.16025321,0.043699572,0.000167192,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -U 0.11 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.11,0.34,0.374,,,,,,,,,,,,,, -U 0.11 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.11,0.38,0.418,,,,,,,,,,,,,, -U 0.12 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.12,0.34,0.374,,,,,,,,,,,,,, -U 0.12 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.12,0.38,0.418,,,,,,,,,,,,,, -U 0.13 SHGC 0.32 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.13,0.32,0.352,,,,,,,,,,,,,, -U 0.13 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.13,0.38,0.418,,,,,,,,,,,,,, -U 0.14 SHGC 0.31 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.14,0.31,0.341,,,,,,,,,,,,,, -U 0.14 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.14,0.34,0.374,,,,,,,,,,,,,, -U 0.14 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.14,0.36,0.396,,,,,,,,,,,,,, -U 0.14 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.14,0.38,0.418,,,,,,,,,,,,,, -U 0.15 SHGC 0.31 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.15,0.31,0.341,,,,,,,,,,,,,, -U 0.15 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.15,0.34,0.374,,,,,,,,,,,,,, -U 0.17 SHGC 0.31 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.17,0.31,0.341,,,,,,,,,,,,,, -U 0.17 SHGC 0.32 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.17,0.32,0.352,,,,,,,,,,,,,, -U 0.17 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.17,0.36,0.396,,,,,,,,,,,,,, -U 0.18 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.18,0.22,0.242,,,,,,,,,,,,,, -U 0.18 SHGC 0.24 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.18,0.24,0.264,,,,,,,,,,,,,, -U 0.20 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.2,0.19,0.209,,,,,,,,,,,,,, -U 0.20 SHGC 0.20 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.2,0.2,0.22,,,,,,,,,,,,,, -U 0.20 SHGC 0.21 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.2,0.21,0.231,,,,,,,,,,,,,, -U 0.20 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.2,0.22,0.242,,,,,,,,,,,,,, -U 0.23 SHGC 0.31 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.23,0.31,0.341,,,,,,,,,,,,,, -U 0.23 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.23,0.34,0.374,,,,,,,,,,,,,, -U 0.25 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.25,0.22,0.242,,,,,,,,,,,,,, -U 0.25 SHGC 0.24 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.25,0.24,0.264,,,,,,,,,,,,,, -U 0.26 SHGC 0.40 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.26,0.4,0.44,,,,,,,,,,,,,, -U 0.29 SHGC 0.40 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.29,0.4,0.44,,,,,,,,,,,,,, -U 0.32 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.32,0.36,0.396,,,,,,,,,,,,,, -U 0.35 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.35,0.22,0.242,,,,,,,,,,,,,, -U 0.35 SHGC 0.24 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.35,0.24,0.264,,,,,,,,,,,,,, -U 0.42 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.42,0.34,0.374,,,,,,,,,,,,,, -U 0.45 SHGC 0.33 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.45,0.33,0.363,,,,,,,,,,,,,, -U 0.47 SHGC 0.33 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.47,0.33,0.363,,,,,,,,,,,,,, -U 0.48 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.48,0.19,0.209,,,,,,,,,,,,,, -U 0.48 SHGC 0.21 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.48,0.21,0.231,,,,,,,,,,,,,, -U 0.48 SHGC 0.20 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.48,0.2,0.22,,,,,,,,,,,,,, -U 0.48 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.48,0.22,0.242,,,,,,,,,,,,,, -U 0.50 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.22,0.242,,,,,,,,,,,,,, -U 0.50 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.23,0.253,,,,,,,,,,,,,, -U 0.52 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.52,0.39,0.31,,,,,,,,,,,,,, -U 0.52 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.52,0.49,0.41,,,,,,,,,,,,,, -U 0.52 SHGC 0.615 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.52,0.615,0.41,,,,,,,,,,,,,, -U 0.54 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.54,0.23,0.253,,,,,,,,,,,,,, -U 0.58 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.58,0.19,0.15,,,,,,,,,,,,,, -U 0.58 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.58,0.36,0.25,,,,,,,,,,,,,, -U 0.59 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.59,0.36,0.27,,,,,,,,,,,,,, -U 0.59 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.59,0.39,0.31,,,,,,,,,,,,,, -U 0.60 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.6,0.23,0.253,,,,,,,,,,,,,, -U 0.61 SHGC 0.77 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.61,0.77,0.6,,,,,,,,,,,,,, -U 0.62 SHGC 0.20 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.62,0.2,0.22,,,,,,,,,,,,,, -U 0.62 SHGC 0.21 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.62,0.21,0.231,,,,,,,,,,,,,, -U 0.62 SHGC 0.41 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.62,0.41,0.32,,,,,,,,,,,,,, -U 0.65 SHGC 0.35 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.65,0.35,0.25,,,,,,,,,,,,,, -U 0.69 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.69,0.19,0.15,,,,,,,,,,,,,, -U 0.69 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.69,0.36,0.23,,,,,,,,,,,,,, -U 0.69 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.69,0.39,0.23,,,,,,,,,,,,,, -U 0.69 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.69,0.49,0.38,,,,,,,,,,,,,, -U 0.69 SHGC 0.64 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.69,0.64,0.55,,,,,,,,,,,,,, -U 0.69 SHGC 0.68 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.69,0.68,0.55,,,,,,,,,,,,,, -U 0.72 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.72,0.25,0.13,,,,,,,,,,,,,, -U 0.72 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.72,0.36,0.23,,,,,,,,,,,,,, -U 0.72 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.72,0.39,0.23,,,,,,,,,,,,,, -U 0.74 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.74,0.55,0.4,,,,,,,,,,,,,, -U 0.74 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.74,0.65,0.55,,,,,,,,,,,,,, -U 0.75 SHGC 0.35 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.35,0.23,,,,,,,,,,,,,, -U 0.81 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.81,0.65,0.55,,,,,,,,,,,,,, -U 0.85 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.85,0.65,0.55,,,,,,,,,,,,,, -U 0.87 SHGC 0.58 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.87,0.58,0.55,,,,,,,,,,,,,, -U 0.87 SHGC 0.71 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.87,0.71,0.6,,,,,,,,,,,,,, -U 0.87 SHGC 0.77 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.87,0.77,0.6,,,,,,,,,,,,,, -U 0.98 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.19,0.15,,,,,,,,,,,,,, -U 0.98 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.36,0.25,,,,,,,,,,,,,, -U 1.10 SHGC 0.62 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.1,0.62,0.55,,,,,,,,,,,,,, -U 1.10 SHGC 0.77 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.1,0.77,0.6,,,,,,,,,,,,,, -U 1.15 SHGC 0.77 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.15,0.77,0.6,,,,,,,,,,,,,, -U 1.17 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.17,0.19,0.15,,,,,,,,,,,,,, -U 1.17 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.17,0.36,0.23,,,,,,,,,,,,,, -U 1.17 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.17,0.39,0.23,,,,,,,,,,,,,, -U 1.17 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.17,0.49,0.38,,,,,,,,,,,,,, -U 1.17 SHGC 0.64 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.17,0.64,0.55,,,,,,,,,,,,,, -U 1.17 SHGC 0.68 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.17,0.68,0.55,,,,,,,,,,,,,, -U 1.22 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.25,0.11,,,,,,,,,,,,,, -U 1.22 SHGC 0.54 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.54,0.38,,,,,,,,,,,,,, -U 1.30 SHGC 0.27 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.3,0.27,0.25,,,,,,,,,,,,,, -U 1.30 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.3,0.34,0.25,,,,,,,,,,,,,, -U 1.30 SHGC 0.62 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.3,0.62,0.55,,,,,,,,,,,,,, -U 1.30 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.3,0.65,0.55,,,,,,,,,,,,,, -U 1.36 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.36,0.19,0.15,,,,,,,,,,,,,, -U 1.36 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.36,0.36,0.23,,,,,,,,,,,,,, -U 1.36 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.36,0.39,0.23,,,,,,,,,,,,,, -U 1.36 SHGC 0.61 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.36,0.61,0.23,,,,,,,,,,,,,, -U 1.70 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.7,0.36,0.23,,,,,,,,,,,,,, -U 1.80 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.8,0.36,0.23,,,,,,,,,,,,,, -U 1.90 SHGC 0.27 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.9,0.27,0.25,,,,,,,,,,,,,, -U 1.90 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.9,0.34,0.25,,,,,,,,,,,,,, -U 1.90 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.9,0.39,0.25,,,,,,,,,,,,,, -U 1.90 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.9,0.65,0.25,,,,,,,,,,,,,, -U 1.98 SHGC 0.16 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.16,0.15,,,,,,,,,,,,,, -U 1.98 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.19,0.15,,,,,,,,,,,,,, -U 1.98 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.36,0.25,,,,,,,,,,,,,, -U 1.98 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.39,0.25,,,,,,,,,,,,,, -U 1.98 SHGC 0.61 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.61,0.25,,,,,,,,,,,,,, -U0.47_SHGC_0.49_SimpleGlazing_Window_05,SimpleGlazing,,,,,,,,,,Air,0.47,0.49,0.81,,,,,,,,,,,,,, -U0.47_SHGC0.46_SimpleGlazing_Window_07,SimpleGlazing,,,,,,,,,,Air,0.47,0.46,0.81,,,,,,,,,,,,,, -U0.47_SHGC0.47_SimpleGlazing_Window_06,SimpleGlazing,,,,,,,,,,Air,0.47,0.47,0.81,,,,,,,,,,,,,, -U0.47_SHGC0.47_SimpleGlazing_Window_11,SimpleGlazing,,,,,,,,,,Air,0.47,0.47,0.81,,,,,,,,,,,,,, -U0.47_SHGC0.5_SimpleGlazing_Window_03,SimpleGlazing,,,,,,,,,,Air,0.47,0.5,0.81,,,,,,,,,,,,,, -U0.77_SHGC_0.77_SimpleGlazing_Window_02,SimpleGlazing,,,,,,,,,,Air,0.77,0.77,0.81,,,,,,,,,,,,,, -U0.77_SHGC0.5_SimpleGlazing_Window_09,SimpleGlazing,,,,,,,,,,Air,0.77,0.5,0.81,,,,,,,,,,,,,, -U0.77_SHGC0.61_SimpleGlazing_Window_08,SimpleGlazing,,,,,,,,,,Air,0.77,0.61,0.81,,,,,,,,,,,,,, -U0.77_SHGC0.62_SimpleGlazing_Window_04,SimpleGlazing,,,,,,,,,,Air,0.77,0.62,0.81,,,,,,,,,,,,,, -U1.23_SHGC0.5_SimpleGlazing_Window_12,SimpleGlazing,,,,,,,,,,Air,1.23,0.5,0.81,,,,,,,,,,,,,, -U1.23_SHGC0.82_SimpleGlazing_Window_01,SimpleGlazing,,,,,,,,,,Air,1.23,0.82,0.81,,,,,,,,,,,,,, -U1.23_SHGC0.82_SimpleGlazing_Window_10,SimpleGlazing,,,,,,,,,,Air,1.23,0.62,0.81,,,,,,,,,,,,,, -Vapor permeable felt - 1/8 in.,StandardOpaqueMaterial,Rough,0.13,2.0796,0.062512022,22,0.3,,,,,,,,,,,,,,,,,,,,, -Vapor seal - 2 layers of mopped 15 lb felt - 1/4 in.,StandardOpaqueMaterial,Rough,0.25,2.0796,0.120215426,22,0.3,,,,,,,,,,,,,,,,,,,,, -Vapor seal - plastic film - 1/16 in.,StandardOpaqueMaterial,Rough,0.63,62.4996,0.010080065,30,0.3,,,,,,,,,,,,,,,,,,,,, -Vermiculite aggregate - 45 lb/ft3 - 1/2 in.,StandardOpaqueMaterial,Smooth,0.5,1.7004,0.294048459,45,0.32,,,,,,,,,,,,,,,,,,,,, -W_m1_R15,StandardOpaqueMaterial,Smooth,2.39403,0.15963,15,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -W_m2_R19,StandardOpaqueMaterial,Smooth,3.03244,0.15963,19,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -W_m3_R21,StandardOpaqueMaterial,Smooth,3.35165,0.15963,21,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -W_T24_2013_R13.99,StandardOpaqueMaterial,Smooth,2.23284,0.15963,13.99,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -W1_R8.60,StandardOpaqueMaterial,Smooth,1.37252,0.15963,8.6,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -W2_R11.13,StandardOpaqueMaterial,Smooth,1.77634,0.15963,11.13,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -W3_R11.36,StandardOpaqueMaterial,Smooth,1.81305,0.15963,11.36,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -W4_R12.62,StandardOpaqueMaterial,Smooth,2.01414,0.15963,12.62,1,0.27,0.9,0.7,0.8,,,,,,,,,,,,,,,,,, -Wall Insulation [31],StandardOpaqueMaterial,MediumRough,1.326771654,0.299525982,4.429571171,5.680944412,0.199914015,0.9,0.5,0.5,,,,,,,,,,,,,,,,,, -Wood - 1 in.,StandardOpaqueMaterial,MediumSmooth,1,1.0404,0.961168781,37.94,0.39,,,,,,,,,,,,,,,,,,,,, -Wood - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,1.0404,0.480584391,37.94,0.39,,,,,,,,,,,,,,,,,,,,, -Wood - 2 in.,StandardOpaqueMaterial,MediumSmooth,2,1.0404,1.922337562,37.94,0.39,,,,,,,,,,,,,,,,,,,,, -Wood - 4 in.,StandardOpaqueMaterial,MediumSmooth,4,1.0404,3.844675125,37.94,0.39,,,,,,,,,,,,,,,,,,,,, -Wood Frame NonRes Wall Insulation-0.73,StandardOpaqueMaterial,MediumRough,0.79835618,0.339740118,2.34990258,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Wood Frame Wall Insulation R-1.61 IP,StandardOpaqueMaterial,MediumRough,0.54621365,0.339740118,1.607739625,16.54340955,0.199866246,0.9,0.7,0.7,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x10 - R11 ins.,MasslessOpaqueMaterial,,,,10.783,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x10 - R13 ins.,MasslessOpaqueMaterial,,,,12.4765,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x10 - R19 ins.,MasslessOpaqueMaterial,,,,17.1561,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x10 - R21 ins.,MasslessOpaqueMaterial,,,,18.5953,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x10 - R22 ins.,MasslessOpaqueMaterial,,,,19.2942,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,21.3129,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,24.4379,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x10 - R38 ins.,MasslessOpaqueMaterial,,,,28.8982,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x10 - R44 ins.,MasslessOpaqueMaterial,,,,31.873,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x10 - R49 ins.,MasslessOpaqueMaterial,,,,34.1444,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x10 - R60 ins.,MasslessOpaqueMaterial,,,,38.5802,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x12 - R11 ins.,MasslessOpaqueMaterial,,,,11.0136,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x12 - R13 ins.,MasslessOpaqueMaterial,,,,12.7862,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x12 - R19 ins.,MasslessOpaqueMaterial,,,,17.7471,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x12 - R21 ins.,MasslessOpaqueMaterial,,,,19.2917,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x12 - R22 ins.,MasslessOpaqueMaterial,,,,20.045,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x12 - R25 ins.,MasslessOpaqueMaterial,,,,22.2328,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x12 - R30 ins.,MasslessOpaqueMaterial,,,,25.6551,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,30.6158,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x12 - R44 ins.,MasslessOpaqueMaterial,,,,33.9752,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x12 - R49 ins.,MasslessOpaqueMaterial,,,,36.5684,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x12 - R60 ins.,MasslessOpaqueMaterial,,,,41.7037,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,9.0352,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,10.1946,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x4 - R19 ins.,MasslessOpaqueMaterial,,,,13.1185,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x4 - R21 ins.,MasslessOpaqueMaterial,,,,13.9437,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x4 - R22 ins.,MasslessOpaqueMaterial,,,,14.333,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x4 - R25 ins.,MasslessOpaqueMaterial,,,,15.4178,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x4 - R30 ins.,MasslessOpaqueMaterial,,,,16.9895,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x4 - R38 ins.,MasslessOpaqueMaterial,,,,19.0316,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x4 - R44 ins.,MasslessOpaqueMaterial,,,,20.278,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x4 - R49 ins.,MasslessOpaqueMaterial,,,,21.1742,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x4 - R60 ins.,MasslessOpaqueMaterial,,,,22.7998,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,9.98167,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,11.416,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,15.2129,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,16.3338,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x6 - R22 ins.,MasslessOpaqueMaterial,,,,16.8706,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x6 - R25 ins.,MasslessOpaqueMaterial,,,,18.394,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x6 - R30 ins.,MasslessOpaqueMaterial,,,,20.6759,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x6 - R38 ins.,MasslessOpaqueMaterial,,,,23.7814,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x6 - R44 ins.,MasslessOpaqueMaterial,,,,25.7599,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x6 - R49 ins.,MasslessOpaqueMaterial,,,,27.2236,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x6 - R60 ins.,MasslessOpaqueMaterial,,,,29.9711,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x8 - R11 ins.,MasslessOpaqueMaterial,,,,10.4438,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x8 - R13 ins.,MasslessOpaqueMaterial,,,,12.0246,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,16.313,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x8 - R21 ins.,MasslessOpaqueMaterial,,,,17.6089,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,18.2344,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x8 - R25 ins.,MasslessOpaqueMaterial,,,,20.0271,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x8 - R30 ins.,MasslessOpaqueMaterial,,,,22.7622,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x8 - R38 ins.,MasslessOpaqueMaterial,,,,26.584,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x8 - R44 ins.,MasslessOpaqueMaterial,,,,29.0808,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x8 - R49 ins.,MasslessOpaqueMaterial,,,,30.96,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 16inOC - 2x8 - R60 ins.,MasslessOpaqueMaterial,,,,34.5633,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x10 - R11 ins.,MasslessOpaqueMaterial,,,,10.8472,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x10 - R13 ins.,MasslessOpaqueMaterial,,,,12.6291,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x10 - R19 ins.,MasslessOpaqueMaterial,,,,17.6705,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x10 - R21 ins.,MasslessOpaqueMaterial,,,,19.2568,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x10 - R22 ins.,MasslessOpaqueMaterial,,,,20.0334,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,22.2995,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,25.8772,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x10 - R38 ins.,MasslessOpaqueMaterial,,,,31.1355,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x10 - R44 ins.,MasslessOpaqueMaterial,,,,34.7459,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x10 - R49 ins.,MasslessOpaqueMaterial,,,,37.5607,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x10 - R60 ins.,MasslessOpaqueMaterial,,,,43.2077,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x12 - R11 ins.,MasslessOpaqueMaterial,,,,11.0095,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x12 - R13 ins.,MasslessOpaqueMaterial,,,,12.8496,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x12 - R19 ins.,MasslessOpaqueMaterial,,,,18.1053,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x12 - R21 ins.,MasslessOpaqueMaterial,,,,19.7743,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x12 - R22 ins.,MasslessOpaqueMaterial,,,,20.594,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x12 - R25 ins.,MasslessOpaqueMaterial,,,,22.9964,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x12 - R30 ins.,MasslessOpaqueMaterial,,,,26.8204,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,32.5111,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x12 - R44 ins.,MasslessOpaqueMaterial,,,,36.4678,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x12 - R49 ins.,MasslessOpaqueMaterial,,,,39.581,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x12 - R60 ins.,MasslessOpaqueMaterial,,,,45.903,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,9.54677,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,10.9003,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x4 - R19 ins.,MasslessOpaqueMaterial,,,,14.4614,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x4 - R21 ins.,MasslessOpaqueMaterial,,,,15.5068,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x4 - R22 ins.,MasslessOpaqueMaterial,,,,16.0065,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x4 - R25 ins.,MasslessOpaqueMaterial,,,,17.421,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x4 - R30 ins.,MasslessOpaqueMaterial,,,,19.5305,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x4 - R38 ins.,MasslessOpaqueMaterial,,,,22.3835,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x4 - R44 ins.,MasslessOpaqueMaterial,,,,24.1906,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x4 - R49 ins.,MasslessOpaqueMaterial,,,,25.5222,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x4 - R60 ins.,MasslessOpaqueMaterial,,,,28.0096,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,10.2668,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,11.8491,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,16.1804,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,17.5004,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x6 - R22 ins.,MasslessOpaqueMaterial,,,,18.1394,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x6 - R25 ins.,MasslessOpaqueMaterial,,,,19.9777,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x6 - R30 ins.,MasslessOpaqueMaterial,,,,22.802,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x6 - R38 ins.,MasslessOpaqueMaterial,,,,26.7885,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x6 - R44 ins.,MasslessOpaqueMaterial,,,,29.4185,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x6 - R49 ins.,MasslessOpaqueMaterial,,,,31.4116,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x6 - R60 ins.,MasslessOpaqueMaterial,,,,35.2661,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x8 - R11 ins.,MasslessOpaqueMaterial,,,,10.6047,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x8 - R13 ins.,MasslessOpaqueMaterial,,,,12.3015,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,17.0358,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x8 - R21 ins.,MasslessOpaqueMaterial,,,,18.5054,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,19.2214,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x8 - R25 ins.,MasslessOpaqueMaterial,,,,21.298,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x8 - R30 ins.,MasslessOpaqueMaterial,,,,24.5383,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x8 - R38 ins.,MasslessOpaqueMaterial,,,,29.2172,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x8 - R44 ins.,MasslessOpaqueMaterial,,,,32.3739,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x8 - R49 ins.,MasslessOpaqueMaterial,,,,34.804,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Attic Floor - 24inOC - 2x8 - R60 ins.,MasslessOpaqueMaterial,,,,39.5997,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 16inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,21.3129,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 16inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,24.4379,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 16inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,30.6158,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 16inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,9.98167,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 16inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,11.416,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 16inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,15.2129,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 16inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,16.313,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 16inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,18.2344,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 24inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,22.2995,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 24inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,25.8772,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 24inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,32.5111,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 24inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,10.2668,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 24inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,11.8491,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 24inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,16.1804,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 24inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,17.0358,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Floor - 24inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,19.2214,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x10 - R22 ins.,MasslessOpaqueMaterial,,,,19.2942,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,21.3129,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,24.4379,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x12 - R30 ins.,MasslessOpaqueMaterial,,,,25.6551,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,30.6158,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x14 - R38 ins.,MasslessOpaqueMaterial,,,,30.6158,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,9.0352,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,10.1946,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,11.2537,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x4 - R19 ins.,MasslessOpaqueMaterial,,,,13.1185,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,9.98167,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,11.416,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x6 - R15 ins.,MasslessOpaqueMaterial,,,,12.7607,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,15.2129,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,16.3338,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,16.313,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 16inOC - 2x8 - R21 ins.,MasslessOpaqueMaterial,,,,17.6089,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x10 - R22 ins.,MasslessOpaqueMaterial,,,,20.0334,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x10 - R25 ins.,MasslessOpaqueMaterial,,,,22.2995,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x10 - R30 ins.,MasslessOpaqueMaterial,,,,25.8772,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x12 - R30 ins.,MasslessOpaqueMaterial,,,,26.8204,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x12 - R38 ins.,MasslessOpaqueMaterial,,,,32.5111,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x14 - R38 ins.,MasslessOpaqueMaterial,,,,32.5111,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,9.54677,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,10.9003,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,12.1652,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x4 - R19 ins.,MasslessOpaqueMaterial,,,,14.4614,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x6 - R11 ins.,MasslessOpaqueMaterial,,,,10.2668,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x6 - R13 ins.,MasslessOpaqueMaterial,,,,11.8491,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x6 - R15 ins.,MasslessOpaqueMaterial,,,,13.359,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,16.1804,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,17.5004,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,17.0358,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Rafter Roof - 24inOC - 2x8 - R21 ins.,MasslessOpaqueMaterial,,,,18.5054,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 16inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,7.12596,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 16inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,7.70165,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 16inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,8.18665,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 16inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,11.7113,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 16inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,12.2507,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 16inOC - 2x6 - R22 ins.,MasslessOpaqueMaterial,,,,12.4993,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 16inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,13.4581,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 16inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,14.5092,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 16inOC - 2x8 - R25 ins.,MasslessOpaqueMaterial,,,,15.4247,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 16inOC - 2x8 - R30 ins.,MasslessOpaqueMaterial,,,,16.7137,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x4 - R11 ins.,MasslessOpaqueMaterial,,,,7.44041,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x4 - R11 ins. AWS,MasslessOpaqueMaterial,,,,8.03106,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x4 - R13 ins.,MasslessOpaqueMaterial,,,,8.09769,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x4 - R13 ins. AWS,MasslessOpaqueMaterial,,,,8.85675,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x4 - R15 ins.,MasslessOpaqueMaterial,,,,8.6586,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x4 - R15 ins. AWS,MasslessOpaqueMaterial,,,,9.57897,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x6 - R19 ins.,MasslessOpaqueMaterial,,,,12.2765,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x6 - R19 ins. AWS,MasslessOpaqueMaterial,,,,13.3502,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x6 - R21 ins.,MasslessOpaqueMaterial,,,,12.8954,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x6 - R21 ins. AWS,MasslessOpaqueMaterial,,,,14.1353,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x6 - R22 ins.,MasslessOpaqueMaterial,,,,13.1824,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x6 - R22 ins. AWS,MasslessOpaqueMaterial,,,,14.5036,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x8 - R19 ins.,MasslessOpaqueMaterial,,,,13.9462,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x8 - R19 ins. AWS,MasslessOpaqueMaterial,,,,14.8435,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x8 - R22 ins.,MasslessOpaqueMaterial,,,,15.1272,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x8 - R22 ins. AWS,MasslessOpaqueMaterial,,,,16.2834,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x8 - R25 ins.,MasslessOpaqueMaterial,,,,16.1678,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x8 - R25 ins. AWS,MasslessOpaqueMaterial,,,,17.5793,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x8 - R30 ins.,MasslessOpaqueMaterial,,,,17.6518,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 24inOC - 2x8 - R30 ins. AWS,MasslessOpaqueMaterial,,,,19.4735,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 48inOC - 2x4 - R11 ins. AWS,MasslessOpaqueMaterial,,,,10.1197,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 48inOC - 2x4 - R13 ins. AWS,MasslessOpaqueMaterial,,,,11.711,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 48inOC - 2x4 - R15 ins. AWS,MasslessOpaqueMaterial,,,,13.2373,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 48inOC - 2x6 - R19 ins. AWS,MasslessOpaqueMaterial,,,,17.2794,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 48inOC - 2x6 - R21 ins. AWS,MasslessOpaqueMaterial,,,,18.8464,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 48inOC - 2x6 - R22 ins. AWS,MasslessOpaqueMaterial,,,,19.6146,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 48inOC - 2x8 - R19 ins. AWS,MasslessOpaqueMaterial,,,,17.8255,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 48inOC - 2x8 - R22 ins. AWS,MasslessOpaqueMaterial,,,,20.3213,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 48inOC - 2x8 - R25 ins. AWS,MasslessOpaqueMaterial,,,,22.7412,,,,,,,,,,,,,,,,,,,,,,, -Wood Framed Wall - 48inOC - 2x8 - R30 ins. AWS,MasslessOpaqueMaterial,,,,26.6149,,,,,,,,,,,,,,,,,,,,,,, -Wood shingles - 3/4 in.,StandardOpaqueMaterial,VeryRough,0.75,0.8304,0.903179191,36.94,0.31,,,,,,,,,,,,,,,,,,,,, -Wood shingles - plain and plastic film faced - 3/4 in.,StandardOpaqueMaterial,VeryRough,0.75,0.8004,0.937031484,22,0.31,,,,,,,,,,,,,,,,,,,,, -Wood Siding,StandardOpaqueMaterial,MediumSmooth,0.393700787,0.762681898,0.516205758,33.99951589,0.289003535,0.9,0.78,0.78,,,,,,,,,,,,,,,,,, -Wood siding - 1/2 in.,StandardOpaqueMaterial,MediumSmooth,0.5,0.6204,0.805931657,36.94,0.28,,,,,,,,,,,,,,,,,,,,, -U 0.49 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.49,0.22,,,,,,,,,,,,,,, -U 0.57 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.57,0.25,,,,,,,,,,,,,,, -U 0.53 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.53,0.25,,,,,,,,,,,,,,, -U 0.48 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.48,0.25,,,,,,,,,,,,,,, -U 0.38 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.38,0.36,,,,,,,,,,,,,,, -U 0.38 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.38,0.38,,,,,,,,,,,,,,, -U 0.36 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.36,0.4,,,,,,,,,,,,,,, -U 0.33 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.33,0.45,,,,,,,,,,,,,,, -U 0.29 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.29,0.45,,,,,,,,,,,,,,, -U 0.5 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.22,,,,,,,,,,,,,,, -U 0.54 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.54,0.25,,,,,,,,,,,,,,, -U 0.49 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.49,0.25,,,,,,,,,,,,,,, -U 0.45 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.45,0.25,,,,,,,,,,,,,,, -U 1.19 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.19,0.45,,,,,,,,,,,,,,, -U 0.73 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.73,0.45,,,,,,,,,,,,,,, -U 0.62 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.62,0.45,,,,,,,,,,,,,,, -U 0.51 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.51,0.45,,,,,,,,,,,,,,, -U 0.38 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.38,0.45,,,,,,,,,,,,,,, -U 0.53 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.53,0.22,,,,,,,,,,,,,,, -U 0.53 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.53,0.23,,,,,,,,,,,,,,, -U 0.38 SHGC 0.35 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.38,0.35,,,,,,,,,,,,,,, -U 0.38 SHGC 0.37 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.38,0.37,,,,,,,,,,,,,,, -U 0.36 SHGC 0.37 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.36,0.37,,,,,,,,,,,,,,, -U 0.31 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.31,0.39,,,,,,,,,,,,,,, -U 0.28 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.28,0.39,,,,,,,,,,,,,,, -U 0.51 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.51,0.22,,,,,,,,,,,,,,, -U 0.51 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.51,0.23,,,,,,,,,,,,,,, -U 0.46 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.46,0.25,,,,,,,,,,,,,,, -U 0.43 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.43,0.25,,,,,,,,,,,,,,, -U 0.36 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.36,0.36,,,,,,,,,,,,,,, -U 0.36 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.36,0.38,,,,,,,,,,,,,,, -U 0.34 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.34,0.38,,,,,,,,,,,,,,, -U 0.29 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.29,0.4,,,,,,,,,,,,,,, -U 0.26 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.26,0.4,,,,,,,,,,,,,,, -U 0.37 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.37,0.36,,,,,,,,,,,,,,, -U 0.37 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.37,0.38,,,,,,,,,,,,,,, -U 0.35 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.35,0.38,,,,,,,,,,,,,,, -U 0.3 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.3,0.4,,,,,,,,,,,,,,, -U 0.27 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.27,0.4,,,,,,,,,,,,,,, -U 0.5 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.23,,,,,,,,,,,,,,, -U 0.42 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.42,0.25,,,,,,,,,,,,,,, -U 0.47 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.47,0.25,,,,,,,,,,,,,,, -U 1.2 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.2,0.45,,,,,,,,,,,,,,, -U 0.5 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.45,,,,,,,,,,,,,,, -U 0.39 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.39,0.45,,,,,,,,,,,,,,, -U 0.36 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.36,0.45,,,,,,,,,,,,,,, -U 0.75 SHGC 0.35 Simple Glazing Window,SimpleGlazing,,,,,,,,,,,0.75,0.35,,,,,,,,,,,,,,, -U 0.65 SHGC 0.35 Simple Glazing Window,SimpleGlazing,,,,,,,,,,,0.65,0.35,,,,,,,,,,,,,,, -U 0.55 SHGC 0.35 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.55,0.35,,,,,,,,,,,,,,, -U 0.5 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.4,,,,,,,,,,,,,,, -U 0.5 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.55,,,,,,,,,,,,,,, -U 0.41 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.41,0.55,,,,,,,,,,,,,,, -U 1.8 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.8,0.55,,,,,,,,,,,,,,, -U 1.7 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.7,0.55,,,,,,,,,,,,,,, -U 1.15 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.15,0.55,,,,,,,,,,,,,,, -U 0.98 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.55,,,,,,,,,,,,,,, -U 0.85 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.85,0.55,,,,,,,,,,,,,,, -U 0.7 SHGC 0.3 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.7,0.3,,,,,,,,,,,,,,, -U 0.65 SHGC 0.3 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.65,0.3,,,,,,,,,,,,,,, -U 0.55 SHGC 0.3 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.55,0.3,,,,,,,,,,,,,,, -U 0.47 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.47,0.4,,,,,,,,,,,,,,, -U 0.44 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.44,0.55,,,,,,,,,,,,,,, -U 0.9 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.9,0.55,,,,,,,,,,,,,,, -U 0.75 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.55,,,,,,,,,,,,,,, -U 0.37 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.37,0.25,,,,,,,,,,,,,,, -U 0.83 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.83,0.25,,,,,,,,,,,,,,, -U 0.77 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.77,0.25,,,,,,,,,,,,,,, -U 0.93 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.93,0.45,,,,,,,,,,,,,,, -U 0.83 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.83,0.45,,,,,,,,,,,,,,, -U 0.65 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.65,0.55,,,,,,,,,,,,,,, -U 1.8 SHGC 0.77 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.8,0.77,,,,,,,,,,,,,,, -U 0.65 SHGC 0.77 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.65,0.77,,,,,,,,,,,,,,, -U 0.65 SHGC 0.68 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.65,0.68,,,,,,,,,,,,,,, -U 1.8 SHGC 0.64 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.8,0.64,,,,,,,,,,,,,,, -U 0.33 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.33,0.25,,,,,,,,,,,,,,, -U 0.68 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.68,0.25,,,,,,,,,,,,,,, -U 0.87 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.87,0.45,,,,,,,,,,,,,,, -U 0.77 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.77,0.45,,,,,,,,,,,,,,, -U 0.55 SHGC 0.64 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.55,0.64,,,,,,,,,,,,,,, -U 0.55 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.55,0.55,,,,,,,,,,,,,,, -U 0.31 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.31,0.36,,,,,,,,,,,,,,, -U 0.68 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.68,0.36,,,,,,,,,,,,,,, -U 0.31 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.31,0.38,,,,,,,,,,,,,,, -U 0.68 SHGC 0.38 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.68,0.38,,,,,,,,,,,,,,, -U 0.45 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.45,0.45,,,,,,,,,,,,,,, -U 0.5 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.36,,,,,,,,,,,,,,, -U 0.5 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.19,,,,,,,,,,,,,,, -U 0.5 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.34,,,,,,,,,,,,,,, -U 0.98 SHGC 0.27 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.27,,,,,,,,,,,,,,, -U 0.98 SHGC 0.36 Simple Glazing Weighted,SimpleGlazing,,,,,,,,,,,0.98,0.36,,,,,,,,,,,,,,, -U 0.68 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.68,0.4,,,,,,,,,,,,,,, -U 0.85 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.85,0.19,,,,,,,,,,,,,,, -U 0.85 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.85,0.39,,,,,,,,,,,,,,, -U 0.28 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.28,0.45,,,,,,,,,,,,,,, -U 0.68 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.68,0.45,,,,,,,,,,,,,,, -U 0.32 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.32,0.45,,,,,,,,,,,,,,, -U 0.5 SHGC 0.27 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.27,,,,,,,,,,,,,,, -U 0.25 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.25,0.45,,,,,,,,,,,,,,, -U 0.5 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.39,,,,,,,,,,,,,,, -U 0.5 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.65,,,,,,,,,,,,,,, -U 0.85 SHGC 0.27 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.85,0.27,,,,,,,,,,,,,,, -U 0.5 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.5,0.25,,,,,,,,,,,,,,, -U 1.1 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.1,0.25,,,,,,,,,,,,,,, -U 1.1 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.1,0.45,,,,,,,,,,,,,,, -U 0.75 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.49,,,,,,,,,,,,,,, -U 1.8 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.8,0.49,,,,,,,,,,,,,,, -U 0.75 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.39,,,,,,,,,,,,,,, -U 0.75 SHGC 0.68 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.68,,,,,,,,,,,,,,, -U 0.75 SHGC 0.64 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.64,,,,,,,,,,,,,,, -U 0.77 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.77,0.23,,,,,,,,,,,,,,, -U 0.68 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.68,0.23,,,,,,,,,,,,,,, -U 0.63 SHGC 0.33 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.63,0.33,,,,,,,,,,,,,,, -U 0.63 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.63,0.34,,,,,,,,,,,,,,, -U 0.63 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.63,0.36,,,,,,,,,,,,,,, -U 0.63 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.63,0.45,,,,,,,,,,,,,,, -U 0.83 SHGC 0.21 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.83,0.21,,,,,,,,,,,,,,, -U 0.32 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.32,0.22,,,,,,,,,,,,,,, -U 0.83 SHGC 0.22 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.83,0.22,,,,,,,,,,,,,,, -U 0.83 SHGC 0.2 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.83,0.2,,,,,,,,,,,,,,, -U 0.6 SHGC 0.23 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.6,0.23,,,,,,,,,,,,,,, -U 0.62 SHGC 0.2 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.62,0.2,,,,,,,,,,,,,,, -U 1.22 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.19,,,,,,,,,,,,,,, -U 1.22 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.45,,,,,,,,,,,,,,, -U 1.22 SHGC 0.17 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.17,,,,,,,,,,,,,,, -U 1.22 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.39,,,,,,,,,,,,,,, -U 0.98 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.45,,,,,,,,,,,,,,, -U 1.98 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.45,,,,,,,,,,,,,,, -U 0.57 SHGC 0.39 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.57,0.39,,,,,,,,,,,,,,, -U 0.46 SHGC 0.19 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.46,0.19,,,,,,,,,,,,,,, -U 1.98 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.34,,,,,,,,,,,,,,, -U 1.22 SHGC 0.61 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.61,,,,,,,,,,,,,,, -U 1.22 SHGC 0.34 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.22,0.34,,,,,,,,,,,,,,, -U 0.57 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.57,0.49,,,,,,,,,,,,,,, -U 0.46 SHGC 0.26 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.46,0.26,,,,,,,,,,,,,,, -U 1.98 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.65,,,,,,,,,,,,,,, -U 0.58 SHGC 0.61 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.58,0.61,,,,,,,,,,,,,,, -U 0.46 SHGC 0.36 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.46,0.36,,,,,,,,,,,,,,, -U 0.46 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.46,0.45,,,,,,,,,,,,,,, -U 0.35 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.35,0.45,,,,,,,,,,,,,,, -U 0.98 SHGC 0.62 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.62,,,,,,,,,,,,,,, -U 0.58 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.58,0.45,,,,,,,,,,,,,,, -U 0.75 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.25,,,,,,,,,,,,,,, -U 0.7 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.7,0.25,,,,,,,,,,,,,,, -U 1.98 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.49,,,,,,,,,,,,,,, -U 0.65 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.65,0.25,,,,,,,,,,,,,,, -U 0.6 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.6,0.25,,,,,,,,,,,,,,, -U 0.9 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.9,0.25,,,,,,,,,,,,,,, -U 1.98 SHGC 0.71 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.71,,,,,,,,,,,,,,, -U 0.4 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.4,0.4,,,,,,,,,,,,,,, -U 0.55 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.55,0.4,,,,,,,,,,,,,,, -U 0.85 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.85,0.4,,,,,,,,,,,,,,, -U 0.35 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.35,0.4,,,,,,,,,,,,,,, -U 0.45 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.45,0.4,,,,,,,,,,,,,,, -U 0.8 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.8,0.4,,,,,,,,,,,,,,, -U 0.65 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.65,0.45,,,,,,,,,,,,,,, -U 0.6 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.6,0.45,,,,,,,,,,,,,,, -U 0.9 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.9,0.45,,,,,,,,,,,,,,, -U 0.4 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.4,0.45,,,,,,,,,,,,,,, -U 0.8 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.8,0.45,,,,,,,,,,,,,,, -U 1.2 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.2,0.25,,,,,,,,,,,,,,, -U 1.98 SHGC 0.27 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.98,0.27,,,,,,,,,,,,,,, -U 1.17 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,1.17,0.45,,,,,,,,,,,,,,, -U 0.98 SHGC 0.49 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.49,,,,,,,,,,,,,,, -U 0.98 SHGC 0.46 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.98,0.46,,,,,,,,,,,,,,, -U 0.58 SHGC 0.65 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.58,0.65,,,,,,,,,,,,,,, -U 0.58 SHGC 0.55 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.58,0.55,,,,,,,,,,,,,,, -U 0.4 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.4,0.25,,,,,,,,,,,,,,, -U 0.35 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.35,0.25,,,,,,,,,,,,,,, -U 0.55 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.55,0.45,,,,,,,,,,,,,,, -U 0.42 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.42,0.4,,,,,,,,,,,,,,, -U 0.77 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.77,0.4,,,,,,,,,,,,,,, -U 0.81 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.81,0.45,,,,,,,,,,,,,,, -U 0.32 SHGC 0.4 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.32,0.4,,,,,,,,,,,,,,, -U 0.7 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.7,0.45,,,,,,,,,,,,,,, -U 0.59 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.59,0.45,,,,,,,,,,,,,,, -U 0.44 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.44,0.45,,,,,,,,,,,,,,, -U 0.93 SHGC 0.25 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.93,0.25,,,,,,,,,,,,,,, -U 0.75 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.75,0.45,,,,,,,,,,,,,,, -U 0.48 SHGC 0.45 Simple Glazing,SimpleGlazing,,,,,,,,,,,0.48,0.45,,,,,,,,,,,,,,, diff --git a/data/openstudio_standards_data/database_files/support_performance_curves.csv b/data/openstudio_standards_data/database_files/support_performance_curves.csv deleted file mode 100644 index c4a7a9d817..0000000000 --- a/data/openstudio_standards_data/database_files/support_performance_curves.csv +++ /dev/null @@ -1,734 +0,0 @@ -name,category,form,dependent_variable,independent_variable_1,independent_variable_2,coeff_1,coeff_2,coeff_3,coeff_4,coeff_5,coeff_6,coeff_7,coeff_8,coeff_9,coeff_10,minimum_independent_variable_1,maximum_independent_variable_1,minimum_independent_variable_2,maximum_independent_variable_2,minimum_dependent_variable_output,maximum_dependent_variable_output,annotation -a-Si_Spectral-fAirMass,PV-Module,Cubic,,AirMass,,0.99264449,0.05334853,-0.0372019,0.00327026,,,,,,,,,,,,,From .dat files included with MASControl2 -Absor-1-Cap-fCHWT&ECT,1-StageAbsorptn,BiQuadratic,QRatio,CHWT,ECT,1.757428,0.054774,-0.00290628,-0.035145,-0.000156,0.000894,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Absor-1-HIR-fCHWT&ECT,1-StageAbsorptn,BiQuadratic,,CHWT,ECT,0.691153,0,0,0.005355,0.000178,0,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Absor-1-HIR-fPLR,1-StageAbsorptn,Quadratic,,PLR,,0.087773,0.744921,0.167306,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Absor-2-Cap-fCHWT&ECT,2-StageAbsorptn,BiQuadratic,QRatio,CHWT,ECT,0.362073,0.0001386,0.001458,0.0733878,-0.00206064,0.00101,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Absor-2-HIR-fCHWT&ECT,2-StageAbsorptn,BiQuadratic,,CHWT,ECT,0.98675,0,0,-0.0234,0.00081,0,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Absor-2-HIR-fPLR,2-StageAbsorptn,Quadratic,,PLR,,0.1355115,0.61798084,0.24651277,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -AHU-1_CoolCStandard10Ton_CapFF,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.77136,0.34053,-0.11088,,,,,,,,0.75918,1.13877,,,,,"From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" -AirCooled_Chiller_2004_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.0433811,0.0407077,0.0004506,-0.0041514,-8.86e-05,-0.0003467,,,,,5,10,12.7,51.67,,,"Based on Dick Lord's study dated January 17, 2010." -AirCooled_Chiller_2004_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.5961915,-0.0099496,0.0007888,0.0004506,0.0004875,-0.0007623,,,,,5,10,12.7,51.67,,,"Based on Dick Lord's study dated January 17, 2010." -AirCooled_Chiller_2010_PathA_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.0433825,0.0407073,0.0004506,-0.0041514,-8.86e-05,-0.0003467,,,,,5,10,12.7,51.67,,,"Based on Dick Lord's study dated January 17, 2010." -AirCooled_Chiller_2010_PathA_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.5961915,-0.0099496,0.0007888,0.0004506,0.0004875,-0.0007623,,,,,5,10,12.7,51.67,,,"Based on Dick Lord's study dated January 17, 2010." -AirCooled_Chiller_AllCapacities_2004_2010_EIRFPLR,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.141,0.655,0.203,,,,,,,,0,1,,,,,"Based on Dick Lord's study dated January 17, 2010. EIRFPLR curve is identical for all AirCooled Chillers" -AirCooled_Chiller_GT150_2004_EIRFPLR,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.141,0.655,0.203,,,,,,,,0,1,,,,,"Based on Dick Lord's study dated January 17, 2010." -AirCooled_Chiller_GT150_2010_PathA_EIRFPLR,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.141,0.655,0.203,,,,,,,,0,1,,,,,"Based on Dick Lord's study dated January 17, 2010." -AirCooled_Chiller_LT150_2004_EIRFPLR,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.141,0.655,0.203,,,,,,,,0,1,,,,,"Based on Dick Lord's study dated January 17, 2010." -AirCooled_Chiller_LT150_2010_PathA_EIRFPLR,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.141,0.655,0.203,,,,,,,,0,1,,,,,"Based on Dick Lord's study dated January 17, 2010." -AirFoil w Dischrg Dampers FPLR,FanEIR-FPLR,Quadratic,,PLR,,0.227143,1.178929,-0.410714,,,,,,,,,,,,0.68,1,From .dat files included with MASControl2 -AirFoil w Inlet Vanes FPLR,FanEIR-FPLR,Quadratic,,PLR,,0.584345,-0.579167,0.970238,,,,,,,,,,,,0.48,1,From .dat files included with MASControl2 -Atmospheric-Blr-HIR-fPLR,FuelBoilers,Quadratic,,PLR,,0.02699999,1.10549998,-0.13249961,,,,,,,,,,,,,,From .dat files included with MASControl2 -Boiler Constant Efficiency Curve,Boiler,Cubic,FIRRatio,QRatio,,1,0,0,0,,,,,,,0,1,,,,,From DOE Reference Building -Boiler with Minimum Turndown,Boiler,Cubic,FIRRatio,QRatio,,0.7791,1.4745,-2.5795,1.3467,,,,,,,0,1.3,,,,,From Regression of Prototype Building EMS -Boiler with No Minimum Turndown,Boiler,Cubic,FIRRatio,QRatio,,0.7463,1.3196,-2.2154,1.1674,,,,,,,0,1.3,,,,,From Regression of Prototype Building EMS -BOILER-EFFFPLR-NECB2011,Boiler,Cubic,FIRRatio,QRatio,,0.2901,2.6664,-3.764,1.82,,,,,,,0,1,,,,,From NECB 2011 -CdTe_Spectral-fAirMass,PV-Module,Cubic,,AirMass,,0.93700588,0.05130703,-0.00646639,0.00017267,,,,,,,,,,,,,From .dat files included with MASControl2 -CentChlrAirCoolCap-fCHW&OAT,Chiller,BiQuadratic,QRatio,CHWT,OAT,0.94533053,0.068473818,-0.003361694,0.000108108,-0.000225,8.2e-05,,,,,,,,,,,From .dat files included with MASControl2 -CentChlrAirCoolEIR-fCHW&OAT,Chiller,BiQuadratic,EIRRatio,CHWT,OAT,0.47343824,0.015708042,-0.000948,0.012260718,9.55e-05,-0.000352,,,,,,,,,,,From .dat files included with MASControl2 -CentChlrAirCoolEIR-fPLR,Chiller,Quadratic,EIRRatio,PLR,,0.24258,0.41468,0.34273973,,,,,,,,,,,,,,From .dat files included with MASControl2 -CentH2O-Cap-fCHWT&ECT,HermCentrifugal,BiQuadratic,QRatio,CHWT,ECT,0.36460761,-0.030523554,-0.001929776,0.066367926,-0.001891966,0.003110627,,,,,,,,,,,From .dat files included with MASControl2 -CentH2O-EIR-fCHWT&ECT,HermCentrifugal,BiQuadratic,EIRRatio,CHWT,ECT,0.65868459,-0.025336458,0.000991,0.01280322,0.000171,-0.000301,,,,,,,,,,,From .dat files included with MASControl2 -CentH2O-EIR-fPLR&dT,HermCentrifugal,BiQuadratic,EIRRatio,PLR,dT,0.27969646,0.57375735,0.25690463,-0.010452906,0.000475,-0.006354126,,,,,,,,,,,From .dat files included with MASControl2 -CentH2OVSD-Cap-fCHWT&ECT,HermCentrifugal,BiQuadratic,QRatio,CHWT,ECT,0.36211013,-0.032249754,-0.000886,0.066743838,-0.001731488,0.002180358,,,,,,,,,,,From .dat files included with MASControl2 -CentH2OVSD-EIR-fCHWT&ECT,HermCentrifugal,BiQuadratic,EIRRatio,CHWT,ECT,0.41386133,-0.088037676,0.00098,0.056770308,-0.000946,0.001418731,,,,,,,,,,,From .dat files included with MASControl2 -CentH2OVSD-EIR-fPLR&dT,HermCentrifugal,BiQuadratic,EIRRatio,PLR,dT,0.14703037,-0.00349667,1.01161313,-0.006474546,0.00088,-0.020960478,,,,,,,,,,,From .dat files included with MASControl2 -ChillerCentCapFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.7446451,0.0114858,1.48e-05,0.022401,-0.000688,0.0009839,,,,,5,10,24,35,,,From Dick Lord's Chiller Model study for ASHRAE 2007 baseline -ChillerCentEIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.772877,0.022101,-7.99e-05,-0.0070045,0.0004763,-0.0010612,,,,,5,10,24,35,,,From Dick Lord's Chiller Model study for ASHRAE 2007 baseline -ChillerCentEIRPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,From Dick Lord's Chiller Model study for ASHRAE 2007 baseline -ChlrAirRecipEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.114437,0.545933,0.342299,,,,,,,,0,1,,,0.11,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrAirRecipEIRRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.542784,-0.013907,0.000476,0.012197,0.000149,-0.000334,,,,,4.44,12.22,23.89,46.11,0.72,1.3,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrAirRecipQRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.12603,0.041571,0.000253,-0.010526,1e-05,-0.000256,,,,,4.44,12.22,23.89,46.11,0.82,1.3,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrAirScrewEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.036487,0.734743,0.219947,,,,,,,,0,1,,,0.04,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrAirScrewEIRRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.570624,0.011954,-0.000522,-3.2e-05,0.000421,-0.000606,,,,,4.44,12.22,23.89,46.11,0.7,1.38,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrAirScrewQRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.985959,0.049487,-0.000298,-0.003737,-4.5e-05,-0.000502,,,,,4.44,12.22,23.89,46.11,0.82,1.3,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrAirScrollEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.063691,0.584888,0.352803,,,,,,,,0,1,,,0.06,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrAirScrollEIRRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.702194,-0.004466,0.000535,-0.005506,0.000544,-0.000729,,,,,4.44,12.22,23.89,46.11,0.69,1.45,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrAirScrollQRatio_fTchwsToadbSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.02138,0.037021,0.000233,-0.003893,-6.5e-05,-0.000269,,,,,4.44,12.22,23.89,46.11,0.82,1.3,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrHPAirCoolCap-fCHW&OAT,Chiller,BiQuadratic,QRatio,CHWT,OAT,1.13076899,0.03157983,0.000358,-0.009856332,1.01e-05,-0.00015,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPAirCoolEIR-fCHW&OAT,Chiller,BiQuadratic,EIRRatio,CHWT,OAT,0.5637406,-0.009225918,0.000353,0.009452178,0.000187,-0.000314,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPAirHeatCap-fHW&39-,Chiller,BiQuadratic,QRatio,HW,39,0.92141508,-0.003413682,-3.86e-06,0.0324,0.000611,-5.18e-05,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPAirHeatCap-fHW&39+,Chiller,BiQuadratic,QRatio,HW,39+,0.94069023,-0.004035888,4.21e-07,0.046218906,-0.001703171,-2.27e-07,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPAirHeatEIR-fHW&39-,Chiller,BiQuadratic,EIRRatio,HW,39,0.33398382,0.019817694,1.2e-05,0.0048024,-3.32e-05,-0.000898,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPAirHeatEIR-fHW&39+,Chiller,BiQuadratic,EIRRatio,HW,39+,0.38886863,0.018107262,1.94e-05,-0.026683668,0.002056655,-0.000499,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPH2OCoolCap_fCHW&ECT,Chiller/HP,BiQuadratic,QRatio,CHWT,ECT,35.68362061,0.62273101,-0.005677932,-0.248948775,-0.003461286,0.011142622,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPH2OCoolCap_fCHW&ECT-Old,Chiller/HP,BiQuadratic,QRatio,CHWT,ECT,0.96601399,0.04050054,0.000589,-0.008098668,6.65e-05,-0.000454,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPH2OCoolEIR_fCHW&ECT,Chiller/HP,BiQuadratic,EIRRatio,CHWT,ECT,0.111287472,-0.002094557,0.000201,0.00170532,0.000168,-0.000308,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPH2OCoolEIR_fCHW&ECT-Old,Chiller/HP,BiQuadratic,EIRRatio,CHWT,ECT,0.61092869,-0.016352352,0.000407,0.003044232,0.000592,-0.000668,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPH2OHeatCap_fHWS&EET,Chiller/HP,BiQuadratic,QRatio,HWS,EET,29.914016,0.1544256,-0.0041472,0.6832512,-0.00203148,0.00199584,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPH2OHeatCap_fHWS&EET-Old,Chiller/HP,BiQuadratic,QRatio,HWS,EET,0.84649612,-0.00264807,2.31e-05,0.02700126,0.00013,-0.000127,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPH2OHeatEIR_fHWS&EET,Chiller/HP,BiQuadratic,EIRRatio,HWS,EET,0.12004,-0.00011232,9.85e-05,-0.00107928,7.32e-05,-0.000134,,,,,,,,,,,From .dat files included with MASControl2 -ChlrHPH2OHeatEIR_fHWS&EET-Old,Chiller/HP,BiQuadratic,EIRRatio,HWS,EET,0.2068226,0.018812142,0.000105,-0.012659724,0.000406,-0.000399,,,,,,,,,,,From .dat files included with MASControl2 -ChlrWtrCentPathAAllEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.222149,0.503156,0.256905,,,,,,,,0.1,1,,,0.28,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrCentPathAAllEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.658643,-0.025339,0.000991,0.012801,0.000171,-0.000301,,,,,4.44,12.22,15.56,29.44,0.68,1.05,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrCentPathAAllQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.364691,-0.030521,-0.00193,0.066374,-0.001892,0.003111,,,,,4.44,12.22,15.56,29.44,0.87,0.91,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrCentPathBGtEql300Lt600tonEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.055483,0.451866,0.488242,,,,,,,,0.1,1,,,0.11,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrCentPathBGtEql300Lt600tonEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.756376,-0.015019,0.000156,0.00246,0.000515,-0.000687,,,,,4.44,12.22,15.56,29.44,0.63,1.12,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrCentPathBGtEql300Lt600tonQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,1.35608,0.04875,-0.000888,-0.014525,-0.000286,-4e-05,,,,,4.44,12.22,15.56,29.44,0.87,1.52,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrCentPathBGtEql600tonEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.107426,0.156775,0.739345,,,,,,,,0.1,1,,,0.13,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrCentPathBGtEql600tonEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.737625,0.001456,-0.000223,0.007116,0.000267,-0.000735,,,,,4.44,12.22,15.56,29.44,0.76,1.08,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrCentPathBGtEql600tonQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.854454,0.042526,-0.000185,0.011697,-0.000497,-0.000412,,,,,4.44,12.22,15.56,29.44,0.9,1.33,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrCentPathBLt300tonEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.208389,-0.121404,0.918455,,,,,,,,0.1,1,,,0.21,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrCentPathBLt300tonEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.711108,-0.023515,0.001194,0.017737,0.000152,-0.001159,,,,,4.44,12.22,15.56,29.44,0.69,1.13,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrCentPathBLt300tonQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,1.15508,0.036503,-0.000499,-0.001455,-0.000439,-0.000172,,,,,4.44,12.22,15.56,29.44,0.86,1.37,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrPosDispPathAAllEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.310965,0.322519,0.372745,,,,,,,,0.1,1,,,0.35,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrPosDispPathAAllEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.665307,-0.009339,0.000483,0.009492,0.000544,-0.000864,,,,,4.44,12.22,15.56,29.44,0.74,1.27,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrPosDispPathAAllQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.96744,0.037082,0.000434,-0.005837,-4.9e-05,-0.000274,,,,,4.44,12.22,15.56,29.44,0.89,1.33,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrPosDispPathBAllEIRRatio_fQRatio,Electric Chiller,Quadratic,EIRRatio,QRatio,,0,0.6206,0.3893,,,,,,,,0.1,1,,,0.07,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrPosDispPathBAllEIRRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.428265,-0.024071,0.000849,0.016416,0.000381,-0.00059,,,,,4.44,12.22,15.56,29.44,0.5,1.07,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ChlrWtrPosDispPathBAllQRatio_fTchwsTcwsSI,Electric Chiller,BiQuadratic,QRatio,Tchws,Tcws,0.899926,0.030102,-0.000332,-0.001743,-9.2e-05,0.000229,,,,,4.44,12.22,15.56,29.44,0.93,1.21,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CHW-Coil-Cap-fAirflow,CHWCoils,Quadratic,QRatio,Airflow,,0.0488,1.38,-0.425,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -CHW-Coil-Cap-fEWB&EWT,CHWCoils,BiQuadratic,QRatio,EWB,EWT,1.6726784,-0.13378464,0.0065124,0.03828096,8.26e-05,-0.005868936,,,,,15.55556,29.44444,4.44444,18.33333,,,From .dat files included with MASControl2 -CHW-Coil-Cap-fFluidFlow,CHWCoils,Quadratic,QRatio,FluidFlow,,0.218,3199.5088,-3280000,,,,,,,,0,1,,,,,From .dat files included with MASControl2 -Coffin Defrost Curve,Refrigerated Case,Cubic,,,,0.3475,0.0296,0.0007,3e-05,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings -Coffin Latent Curve,Refrigerated Case,Cubic,,,,0.3379,0.0309,0.0005,4e-05,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings -COIL-BF-FFLOW-SPEC,CoilBF-FFLOW,Linear,,Flow,,0.33,1419.6496,,,,,,,,,,,,,0.8,,From .dat files included with MASControl2 -Coil-Bypass-Factor-fPLR,CHWCoils,Linear,QRatio,PLR,,1,0,,,,,,,,,,,,,,,From .dat files included with MASControl2 -CoilClgDXDblEIRRatio_fCFMRatio,DX Cooling Coil,Cubic,EIRRatio,FlowRatio,,1.007948,0.345441,-0.692289,0.338899,,,,,,,0,1,,,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgDXDblQRatio_fCFMRatio,DX Cooling Coil,Cubic,QRatio,FlowRatio,,0.472786,1.243342,-1.038706,0.322578,,,,,,,-100,100,0.47,,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgDXEIRRatio_fQFrac,DX Cooling Coil,Cubic,EIRRatio,QRatio,,0,5.1091,-8.5515,4.4744,,,,,,,0.7,1,0.92,1,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgDXEIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.116709,0.028458,-0.000411,0.021422,0.000162,-0.00068,,,,,13.89,25,23.89,46.11,0.77,1.33,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgDXQRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.86779,0.014245,0.000554,-0.007569,3.2e-05,-0.000191,,,,,13.89,25,23.89,46.11,0.77,1.29,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgDXSEER13EER11EIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,-0.199992,-0.035686,0.000787,0.074834,-0.000516,-0.000573,,,,,13.89,25,23.89,46.11,0.55,1.44,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgDXSEER15EER11EIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,-1.790474,-0.028777,0.000763,0.153391,-0.001482,-0.000721,,,,,13.89,25,23.89,46.11,0.35,1.42,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgDXSEER16EER13EIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.686684,-0.035826,0.000781,0.025564,0.000163,-0.000559,,,,,13.89,25,23.89,46.11,0.65,1.51,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgDXSEER17EER11EIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,-3.060538,-0.023207,0.000744,0.216093,-0.002253,-0.000839,,,,,13.89,25,23.89,46.11,0.2,1.4,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgDXSEER18EER13EIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,-1.247121,-0.027513,0.000752,0.121123,-0.001013,-0.000736,,,,,13.89,25,23.89,46.11,0.41,1.48,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgDXSEER20EER13EIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,-2.72492,-0.02112,0.00073,0.194128,-0.001911,-0.000872,,,,,13.89,25,23.89,46.11,0.23,1.45,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgDXSEEREIRRatio_fQFrac,DX Cooling Coil,Cubic,EIRRatio,QRatio,,1,0,0,0,,,,,,,0.7,1,1,1,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgDXSnglEIRRatio_fCFMRatio,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.156,-0.1816,0.0256,,,,,,,,0,1,,,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgDXSnglQRatio_fCFMRatio,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgPTACEIRRatio_fQFrac,DX Cooling Coil,Cubic,EIRRatio,QRatio,,0.85,0.15,0,0,,,,,,,0.7,1,0.96,1,,,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgPTACEIRRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.341434,0.03481,-0.000625,0.004941,0.000437,-0.000729,,,,,13.89,25,23.89,46.11,0.75,1.4,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -CoilClgPTACQRatio_fTwbToadbSI,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.942879,0.009538,0.000684,-0.011002,6e-06,-1e-05,,,,,13.89,25,23.89,46.11,0.71,1.34,From CBECC Appendix_3.7_PerformanceCurves-S901G.xlsx -ConstantCubic,,Cubic,,,,1,0,0,0,,,,,,,-100,100,,,,,From Reference Buildings -Cool-PLF-fPLR,DX Cooling Coil,Quadratic,EIRRatio,QRatio,,0.90949556,0.09864773,-0.00819488,,,,,,,,0,1,,,,,From PNNL Prototype FullServiceRestaurant -CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.2055,-0.32953,0.12308,,,,,,,,0.75918,1.13877,,,,,"From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" -Curve_Biquadratic_CBES_01,,BiQuadratic,,,,0.86779,0.014245,0.000554,-0.007569,3.2e-05,-0.000191,,,,,0,100,0,100,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov -Curve_Biquadratic_CBES_02,,BiQuadratic,,,,-0.199992,-0.035686,0.000787,0.074834,-0.000516,-0.000573,,,,,13.9,25,23.9,43.3,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov -Curve_Biquadratic_CBES_03,,BiQuadratic,,,,0.9425878,0.00954335,0.00068377,-0.0110427,5.25e-06,-9.72e-06,,,,,17,22,13,46,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov -Curve_Biquadratic_CBES_04,,BiQuadratic,,,,0.3424144,0.03488501,-0.0006237,0.00497722,0.00043795,-0.000728,,,,,17,22,13,46,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov -Curve_Quadratic_CBES_01,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov -Curve_Quadratic_CBES_02,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.156,-0.1816,0.0256,,,,,,,,0.5,1.5,,,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov -Curve_Quadratic_CBES_03,,Quadratic,,,,1,0,0,,,,,,,,0,1,,,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov -Curve_Quadratic_CBES_04,,Quadratic,,,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov -Curve_Quadratic_CBES_05,,Quadratic,,,,1.1552,-0.1808,0.0256,,,,,,,,0.5,1.5,,,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov -Curve_Quadratic_CBES_06,,Quadratic,,,,0.85,0.15,0,,,,,,,,0,1,,,,,From Commercial Building Energy Saver (CBES) Prototype Models: cbes.lbl.gov -DEER DHW HIR-FPLR Curve,DEERDHWHIR-FPLR,Linear,,PLR,,0,1,,,,,,,,,,,,,,,From .dat files included with MASControl2 -DEER_defrost,Refrigeration,Cubic,,,,0.023632,0.0006232,2.832e-05,4.4035e-07,,,,,,,-23,7,,,,, -DEER_Heat_Rejections_LT,Refrigeration,Linear,Capacity,DeltaT,,0,16383.61446,,,,,,,,,-100,100,,,,,From eQuest Grocery store model -DEER_Heat_Rejections_MT,Refrigeration,Linear,Capacity,DeltaT,,0,20626.34211,,,,,,,,,-100,100,,,,,From eQuest Grocery store model -Default_Case_Latent_Cedit_Curve,Refrigeration,Cubic,,,,0.026526281,0.001078032,-6.02558e-05,1.23732e-06,,,,,,,-35,20,,,,, -Defrost-ResisDem-Frac-fOWB&ODB,DXCool/Heat,BiLinear,QRatio,OWB,ODB,0.0333,0,0,,,,,,,,-23.333,29.444,-23.333,29.444,,,From .dat files included with MASControl2 -Defrost-ResisTime-Frac-fOWB&ODB,DXCool/Heat,BiLinear,QRatio,OWB,ODB,0.0333,0,0,,,,,,,,-23.333,29.444,-23.333,29.444,,,From .dat files included with MASControl2 -Defrost-ReversDem-Frac-fOWB&ODB,DXCool/Heat,BiLinear,QRatio,OWB,ODB,0.0333,0,0,,,,,,,,-23.333,29.444,-23.333,29.444,,,From .dat files included with MASControl2 -Defrost-ReversTime-Frac-fOWB&ODB,DXCool/Heat,BiLinear,QRatio,OWB,ODB,0.0583,0,0,,,,,,,,-23.333,29.444,-23.333,29.444,,,From .dat files included with MASControl2 -Desc-Gas-fT&W,Desiccant,BiQuadratic,,T,W,18784.36736,-3209.524992,-11.8830564,3874.59,-1.69627,-23.53176,,,,,7.22222,46.11111,0,0.1,,,From .dat files included with MASControl2 -Desc-HR8-fWB1&WB6,Desiccant,BiQuadratic,,WB1,WB6,-0.27680768,0.071770464,0.000735,0.145668672,0.000591,-0.002648246,,,,,12.77778,46.11111,12.77778,46.11111,,,From .dat files included with MASControl2 -Desc-HR8PL-fWB1&WB6,Desiccant,BiQuadratic,,WB1,WB6,-0.05234208,0.076111488,0.000502,0.11464641,0.001235315,-0.002453879,,,,,12.77778,46.11111,12.77778,46.11111,,,From .dat files included with MASControl2 -Desc-kW-fT&W,Desiccant,BiQuadratic,,T,W,3.33024,-0.010674,0,0.00404,0,0,,,,,7.22222,46.11111,0,0.1,,,From .dat files included with MASControl2 -Desc-QREG-fWB1&WB6,Desiccant,BiQuadratic,,WB1,WB6,80.58068736,-0.627217344,0.0170748,-2.186211312,4.37e-05,0.018960674,,,,,12.77778,40.55556,12.77778,46.11111,,,From .dat files included with MASControl2 -Desc-QREGPL-fWB1&WB6,Desiccant,BiQuadratic,,WB1,WB6,20.30901408,-0.159663744,0.0046008,-0.586622934,-0.00024,0.005206064,,,,,12.77778,46.11111,12.77778,46.11111,,,From .dat files included with MASControl2 -Desc-T-fT&W,Desiccant,BiQuadratic,,T,W,31.53328,1.0173168,-0.0033372,0.295,-0.00017,-0.0015696,,,,,7.22222,46.11111,0,0.1,,,From .dat files included with MASControl2 -Desc-T8-fWB1&WB6,Desiccant,BiLinear,,WB1,WB6,34.64,1.6236,0.2574,,,,,,,,12.77778,46.11111,12.77778,46.11111,,,From .dat files included with MASControl2 -Desc-T8PL-fWB1&WB6,Desiccant,BiLinear,,WB1,WB6,32.7692,1.7496,0.06588,,,,,,,,12.77778,46.11111,12.77778,46.11111,,,From .dat files included with MASControl2 -Desc-W-fT&W,Desiccant,BiQuadratic,,T,W,7.82704,0.119376,0.0144504,0.0831,0.000697,0.002862,,,,,7.22222,46.11111,0,0.1,,,From .dat files included with MASControl2 -Direct-Effectiveness-fFlow,EvapCooler,Quadratic,,Flow,,1.18,-546.67104,333000,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -DOE Ref DX Clg Coil Cool-CAP-fFlow,DX Cooling Coil,Cubic,QRatio,FlowRatio,,1,0,0,0,,,,,,,-100,100,,,,,From DOE Pre-1980 Reference Building -DOE Ref DX Clg Coil Cool-Cap-fT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.9712123,-0.015275502,0.001443452,-0.00039321,-6.8364e-06,-0.000290596,,,,,-100,100,-100,100,,,From DOE Pre-1980 Reference Building -DOE Ref DX Clg Coil Cool-EIR-fFlow,DX Cooling Coil,Cubic,EIRRatio,FlowRatio,,1,0,0,0,,,,,,,-100,100,,,,,From DOE Pre-1980 Reference Building -DOE Ref DX Clg Coil Cool-EIR-fT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.28687133,0.023902164,-0.000810648,0.013458546,0.000338936,-0.000487004,,,,,-100,100,-100,100,,,From DOE Pre-1980 Reference Building -DOE Ref DX Clg Coil Cool-PLF-fPLR,DX Cooling Coil,Quadratic,EIRRatio,QRatio,,0.90949556,0.09864773,-0.00819488,,,,,,,,0,1,,,,, -Draft-Fan-EIR-fPLR,FuelBoilers,Cubic,EIRRatio,PLR,,0.35071223,0.3080535,-0.5413736,0.87198823,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -DW-Elec-EIR-fPLR,ElecDW-Heater,Linear,EIRRatio,PLR,,0,1,,,,,,,,,,,,,,,From .dat files included with MASControl2 -DW-Gas-HIR-fPLR,GasDW-Heater,Quadratic,,PLR,,0.021826,0.97763,0.000543,,,,,,,,,,,,,,From .dat files included with MASControl2 -DW-Gas-Pilotless-HIR-fPLR,GasDW-Heater,Quadratic,,PLR,,0,0.999457,0.000543,,,,,,,,,,,,,,From .dat files included with MASControl2 -DW-HeatPump-Cap-fSupplyT&EDB,HeatPumpDW-Heat,BiQuadratic,QRatio,SupplyT,EDB,0.74922298,0,0,0.028130328,0.000236,0,,,,,,,,,,,From .dat files included with MASControl2 -DW-HeatPump-EIR-fPLR,HeatPumpDW-Heat,Cubic,EIRRatio,PLR,,0.08565215,0.93881371,-0.1834361,0.15897022,,,,,,,,,,,,,From .dat files included with MASControl2 -DW-HeatPump-EIR-fSupplyT&EDB,HeatPumpDW-Heat,BiQuadratic,EIRRatio,SupplyT,EDB,1.25311702,0,0,-0.033921486,0.000426,0,,,,,,,,,,,From .dat files included with MASControl2 -DX Coil Cap-FF,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,,"From PNNL Prototype Buildings ApartmentMidRise, HotelSmall, OfficeSmall, RetailStandAlone, RetailStripmall, SchoolPrimary, Warehouse" -DX-Bypass-Factor-fAirflow,DXCool/Heat,Quadratic,QRatio,Airflow,,-0.2542341,1.2182557,0.03597841,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -DX-Bypass-Factor-fEWB&EDB,DXCool/Heat,BiQuadratic,QRatio,EWB,EDB,0.8463094,0.014259096,0.000184,-0.014791716,-5.48e-06,0.000487,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -DX-Bypass-Factor-fPLR,DXCool/Heat,Linear,QRatio,PLR,,1,0,,,,,,,,,,,,,,,From .dat files included with MASControl2 -DX-Cap-fAirflow,DXCool/Heat,Cubic,QRatio,Airflow,,0.06429396,1.99755645,-1.44277024,0.38091758,,,,,,,,,,,,,From .dat files included with MASControl2 -DX-Cool-Cap-fEWB&OAT,DXCool/Heat,BiQuadratic,QRatio,EWB,OAT,0.86791562,0.014247648,0.000554,-0.007558056,3.3e-05,-0.000192,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -DX-Cool-Cap-fRPM&OAT,DXCool/Heat,BiQuadratic,QRatio,RPM,OAT,32,9.549296596,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 -DX-Cool-CondFan-fPLR&OAT,DXCool/Heat,BiQuadratic,PwrRatio,PLR,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 -DX-Cool-CycleLoss-fPLR,DXCool/Heat,Linear,QRatio,PLR,,0.7,0.3,,,,,,,,,,,,,,,From .dat files included with MASControl2 -DX-Cool-EIR-fEWB&OAT,DXCool/Heat,BiQuadratic,EIRRatio,EWB,OAT,0.1210048,0.0285336,-0.000411,0.02134944,0.000161,-0.00068,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -DX-Cool-EIR-fPLR,DXCool/Heat,Cubic,EIRRatio,PLR,,0.201,-0.0312,1.95,-1.12,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -DX-Cool-EIR-fRPM&OAT,DXCool/Heat,BiQuadratic,EIRRatio,RPM,OAT,32,9.549296596,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 -DX-Cool-Waste-Heat-fEWB&OAT,DXCool/Heat,BiLinear,QRatio,EWB,OAT,1,0,0,,,,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -DX-Cool-Waste-Heat-fRPM&OAT,DXCool/Heat,BiQuadratic,QRatio,RPM,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 -DX-Heat-Cap-fEDB&OAT,DXCool/Heat,BiQuadratic,QRatio,EDB,OAT,0.7422592,0,0,0.030682602,3.23e-05,0,,,,,12.77778,29.44444,-12.22222,29.44444,,,From .dat files included with MASControl2 -DX-Heat-Cap-fRPM&OAT,DXCool/Heat,BiQuadratic,QRatio,RPM,OAT,32,9.549296596,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 -DX-Heat-CondFan-fPLR&OAT,DXCool/Heat,BiQuadratic,PwrRatio,PLR,OAT,1,0,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 -DX-Heat-CycleLoss-fPLR,DXCool/Heat,Linear,QRatio,PLR,,0.75,0.25,,,,,,,,,,,,,,,From .dat files included with MASControl2 -DX-Heat-EIR-fEDB&OAT,DXCool/Heat,BiQuadratic,EIRRatio,EDB,OAT,1.25399584,0,0,-0.040063338,0.0010877,0,,,,,12.77778,29.44444,-12.22222,29.44444,,,From .dat files included with MASControl2 -DX-Heat-EIR-fPLR,DXCool/Heat,Cubic,EIRRatio,PLR,,0.0857,0.939,-0.183,0.159,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -DX-Heat-EIR-fRPM&OAT,DXCool/Heat,BiQuadratic,EIRRatio,RPM,OAT,32,9.549296596,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 -DX-Heat-Waste-Heat-fEDB&OAT,DXCool/Heat,BiLinear,QRatio,EDB,OAT,1,0,0,,,,,,,,12.77778,29.44444,-12.22222,29.44444,,,From .dat files included with MASControl2 -DX-Heat-Waste-Heat-fRPM&OAT,DXCool/Heat,BiQuadratic,QRatio,RPM,OAT,1,0,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 -DX-Sens-Cap-fAirflow,DXCool/Heat,Cubic,QRatio,Airflow,,0.34465606,0.89289891,-0.3554498,0.1178948,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -DX-Sens-Cap-fEWB&OAT,DXCool/Heat,BiQuadratic,QRatio,EWB,OAT,2.93224448,-0.09445968,0.0002,-0.007176816,1.03e-05,0.000109,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -DXCOOL-NECB2011-REF-CAPFFLOW,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,1,0,0,,,,,,,,0,1,,,,,From NECB 2011 -DXCOOL-NECB2011-REF-CAPFT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.867905,0.0142459,0.00055436,-0.0075575,3.3e-05,-0.0001918,,,,,13,24,24,46,,,From NECB 2011 -DXCOOL-NECB2011-REF-COOLEIRFFLOW,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1,0,0,,,,,,,,0,1,,,,,From NECB 2011 -DXCOOL-NECB2011-REF-COOLEIRFT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.116936,0.0284933,-0.0004112,0.0214108,0.00016103,-0.0006791,,,,,13,24,24,46,,,From NECB 2011 -DXCOOL-NECB2011-REF-COOLPLFFPLR,DX Cooling Coil,Cubic,EIRRatio,QRatio,,0.0277,4.9151,-8.184,4.2702,,,,,,,0.7,1,,,,,"From NECB, curve modified to take into account how PLF is used in E+, and PLF ranges (> 0.7)" -DXHEAT-NECB2011-REF-CAPFFLOW,DX Heating Coil,Cubic,QRatio,FlowRatio,,0.84,0.16,0,0,,,,,,,0.5,1.5,,,,,From NECB 2011 -DXHEAT-NECB2011-REF-CAPFT,DX Heating Coil,Cubic,QRatio,Toadb,,0.729,0.0319,0.000136,-8.75e-06,,,,,,,-20,20,,,,,From NECB 2011 -DXHEAT-NECB2011-REF-EIRFFLOW,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.3824,-0.4336,0.0512,,,,,,,,0,1,,,,,From NECB 2011 -DXHEAT-NECB2011-REF-EIRFT,DX Heating Coil,Cubic,EIRRatio,Toadb,,1.2183,-0.03612,0.00142,-2.68e-05,,,,,,,-20,20,,,,,From NECB 2011 -DXHEAT-NECB2011-REF-PLFFPLR,DX Heating Coil,Cubic,EIRRatio,QRatio,,0.3696,2.3362,-2.9577,1.2596,,,,,,,0.7,1,,,,,From NECB 2011 -Minisplit-Heat-Cap-fT,DX Heating Coil,BiQuadratic,QRatio,Tiadb,Toadb,1.14715889,-0.010386676,0,0.008653846,0,0,,,,,-100,100,-100,100,,,From OpenStudio-HPXML -Minisplit-Heat-Cap-fFF,DX Heating Coil,Quadratic,QRatio,Tiadb,Toadb,1,0,0,,,,,,,,0,2,0,2,,,From OpenStudio-HPXML -Minisplit-Heat-EIR-fT,DX Heating Coil,BiQuadratic,EIRRatio,Tiadb,Toadb,0.99999417,0.004684594,5.90129e-05,-0.002862447,1.30411e-05,-0.000161729,,,,,-100,100,-100,100,,,From OpenStudio-HPXML -Minisplit-Heat-EIR-fFF,DX Heating Coil,Quadratic,EIRRatio,Tiadb,Toadb,1,0,0,,,,,,,,0,2,0,2,,,From OpenStudio-HPXML -Minisplit-Heat-PLF-fPLR,DX Heating Coil,BiQuadratic,EIRRatio,Tiadb,Toadb,0.89,0.11,,,,,,,,,0,1,0.6,1,,,From OpenStudio-HPXML -Minisplit-Cool-Cap-fT,DX Cooling Coil,BiQuadratic,QRatio,Tiadb,Toadb,0.75319835,0.003618194,0,0.006574385,-6.87181e-05,0,,,,,0,100,0,100,,,From OpenStudio-HPXML -Minisplit-Cool-Cap-fFF,DX Cooling Coil,Quadratic,QRatio,Tiadb,Toadb,1,0,0,,,,,,,,0,2,0,2,,,From OpenStudio-HPXML -Minisplit-Cool-EIR-fT,DX Cooling Coil,BiQuadratic,EIRRatio,Tiadb,Toadb,-0.063769248,-0.001336059,1.41306e-05,0.019433076,-4.91396e-05,-4.90934e-05,,,,,0,100,0,100,,,From OpenStudio-HPXML -Minisplit-Cool-EIR-fFF,DX Cooling Coil,Quadratic,EIRRatio,Tiadb,Toadb,1,0,0,,,,,,,,0,2,0,2,,,From OpenStudio-HPXML -Minisplit-Cool-PLF-fPLR,DX Cooling Coil,BiQuadratic,EIRRatio,Tiadb,Toadb,0.89,0.11,,,,,,,,,0,1,0.6,1,,,From OpenStudio-HPXML -EFG-Si_Spectral-fAirMass,PV-Module,Cubic,,AirMass,,0.93235892,0.05557786,-0.00723784,0.00016577,,,,,,,,,,,,,From .dat files included with MASControl2 -Elec-HW-Blr-EIR-fPLR,ElecBoilers,Linear,EIRRatio,PLR,,0.02,0.98,,,,,,,,,,,,,,,From .dat files included with MASControl2 -Elec-Stm-Blr-EIR-fPLR,ElecBoilers,Linear,EIRRatio,PLR,,0.03,0.97,,,,,,,,,,,,,,,From .dat files included with MASControl2 -Engine-Chlr-Cap-fCHWT&ECT,EngineChiller,BiQuadratic,QRatio,CHWT,ECT,1.02245976,0.033624396,0,-0.00837585,0,0,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Engine-Chlr-HeatRej-fECT,EngineChiller,Cubic,,ECT,,0.81658293,0.00622926,0,0,,,,,,,60,150,,,,,From .dat files included with MASControl2 -Engine-Chlr-HeatRej-fPLR,EngineChiller,Cubic,,PLR,,1.05269921,-0.05269912,0,0,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Engine-Chlr-HIR-fCHWT&ECT,EngineChiller,BiQuadratic,,CHWT,ECT,0.76855672,-0.016619742,0.001163452,0.007451082,0.000302,-0.000971,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Engine-Chlr-HIR-fPLR,EngineChiller,Quadratic,,PLR,,0.12571636,0.34714213,0.52714163,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Engine-Exh-fPLR,EngineGenerator,Quadratic,,PLR,,0.024516,0.3323871,0.6430968,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Engine-HIR-fPLR,EngineGenerator,Linear,,PLR,,0.107,0.893,,,,,,,,,,,,,,,From .dat files included with MASControl2 -Engine-Jac-fPLR,EngineGenerator,Quadratic,,PLR,,0.287936,1.0204516,-0.3083871,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -FluidCooler-FluidCap-fApp&WB,FluidCooler,BiQuadratic,QRatio,App,WB,-0.16463568,0.048677022,-0.001437296,0.072275256,0.000924,0.005085439,,,,,,,,,,,From .dat files included with MASControl2 -FluidCooler-FluidCap-fRng&WB,FluidCooler,BiQuadratic,QRatio,Rng,WB,0,0.18,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 -ForcedDraft-Blr-HIR-fPLR,FuelBoilers,Quadratic,,PLR,,0.01599992,0.94495332,0.03904687,,,,,,,,,,,,,,From .dat files included with MASControl2 -ForCurve w Dischrg Dampers FPLR,FanEIR-FPLR,Quadratic,,PLR,,0.190667,0.31,0.5,,,,,,,,,,,,0.22,1,From .dat files included with MASControl2 -ForCurve w Inlet Vanes FPLR,FanEIR-FPLR,Quadratic,,PLR,,0.339619,-0.848139,1.495671,,,,,,,,,,,,0.22,1,From .dat files included with MASControl2 -FURNACE_PACU_VAV_CoolCCarrier48TM014_12tons_EIRFFF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.19525,-0.306138,0.110973,,,,,,,,0.75,1.25,,,,,From PNNL OfficeMedium -FURNACE_PACU_VAV_CoolCCarrier48TM014_12tons_EIRFT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,-0.536161,0.105138,-0.00172659,0.0149848,0.000659948,-0.0017385,,,,,16.5556,22.1111,23.7778,47.66,,,From PNNL Prototype Buildings OfficeMedium -FURNACE-EFFPLR-NECB2011,Gas Heating Coil,Cubic,FIRRatio,QRatio,,0.7277,1.0667,-1.5174,0.7282,,,,,,,0,1,,,,,From NECB 2011 -Furnace-HIR-fPLR,Furnace,Quadratic,FIRRatio,PLR,,0.0186,1.09,-0.113,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Gas-Absor-Cap-fCHWT&ECT,Chiller/Heater,BiQuadratic,QRatio,CHWT,ECT,0.362073,0.0001386,0.001458,0.0733878,-0.00206064,0.00101,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Gas-Absor-HCap-fCoolPLR,Chiller/Heater,Quadratic,QRatio,CoolPLR,,0.863599,-1.30495346,0.44135284,,,,,,,,,,,,,,From .dat files included with MASControl2 -Gas-Absor-HIR-fCHWT&ECT,Chiller/Heater,BiQuadratic,,CHWT,ECT,0.96182051,-0.0507105,0.003155468,0.005732838,0.000349,-0.00118516,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Gas-Absor-HIR-fDesiccantT,Chiller/Heater,Cubic,,DesiccantT,,0.85427336,0.002997504,4.26e-05,0,,,,,,,100,300,,,,,From .dat files included with MASControl2 -Gas-Absor-Qreg-fDesiccantT,Chiller/Heater,Cubic,,DesiccantT,,0.5984,-0.00234,0,0,,,,,,,100,300,,,,,From .dat files included with MASControl2 -GasTurbine-Cap-fPLR,GasTurbineGen,Linear,QRatio,PLR,,1.24,-0.0041,,,,,,,,,,,,,,,From .dat files included with MASControl2 -GasTurbine-Exh-fPLR,GasTurbineGen,Quadratic,,PLR,,0.295626,0.4930194,0.2113548,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -GasTurbine-HIR-fPLR,GasTurbineGen,Quadratic,,PLR,,0.442979,0.3974,0.1569621,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -GHP-Bypass-Factor-fAirflow,GasHeat-Pump,Quadratic,QRatio,Airflow,,-0.254,1.22,0.036,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -GHP-Bypass-Factor-fEWB&EDB,GasHeat-Pump,BiQuadratic,QRatio,EWB,EDB,0.85028352,0.014256792,0.000184,-0.014791716,-5.48e-06,0.000487,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -GHP-Bypass-Factor-fPLR,GasHeat-Pump,Linear,QRatio,PLR,,1,0,,,,,,,,,,,,,,,From .dat files included with MASControl2 -GHP-Cool-Cap-fEWB&OAT,GasHeat-Pump,BiLinear,QRatio,EWB,OAT,1.1688,0.01926,-0.01539,,,,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -GHP-Cool-Cap-fRPM&OAT,GasHeat-Pump,BiQuadratic,QRatio,RPM,OAT,-372.736,-234.129654,-36.65800433,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 -GHP-Cool-CondFan-fPLR&OAT,GasHeat-Pump,BiQuadratic,,PLR,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 -GHP-Cool-CycleLoss-fPLR,GasHeat-Pump,Linear,QRatio,PLR,,0.82,0.18,,,,,,,,,,,,,,,From .dat files included with MASControl2 -GHP-Cool-HIR-fEWB&OAT,GasHeat-Pump,BiQuadratic,,EWB,OAT,1.1386752,-0.049248,0.000914,0.02128896,0.000306,-0.000953,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -GHP-Cool-HIR-fRPM&OAT,GasHeat-Pump,BiQuadratic,,RPM,OAT,-369.60598,-234.0532596,-36.93157152,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 -GHP-Cool-Waste-Heat-fEWB&OAT,GasHeat-Pump,BiLinear,QRatio,EWB,OAT,1,0,0,,,,,,,,,,,,,,From .dat files included with MASControl2 -GHP-Cool-Waste-Heat-fRPM&OAT,GasHeat-Pump,BiQuadratic,QRatio,RPM,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 -GHP-Defrost-Frac-fOWB&ODB,GasHeat-Pump,BiLinear,QRatio,OWB,ODB,0.0333,0,0,,,,,,,,-23.33333,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 -GHP-Heat-Cap-fEDB&OAT,GasHeat-Pump,BiQuadratic,QRatio,EDB,OAT,0.8291632,0,0,0.01817136,0.000281,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 -GHP-Heat-Cap-fRPM&OAT,GasHeat-Pump,BiQuadratic,QRatio,RPM,OAT,157.86,89.17133162,12.58409104,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 -GHP-Heat-CondFan-fPLR&OAT,GasHeat-Pump,BiQuadratic,,PLR,OAT,1,0,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 -GHP-Heat-CycleLoss-fPLR,GasHeat-Pump,Linear,QRatio,PLR,,0.82,0.18,,,,,,,,,,,,,,,From .dat files included with MASControl2 -GHP-Heat-HIR-fEDB&OAT,GasHeat-Pump,BiQuadratic,,EDB,OAT,1.14897728,0,0,-0.017395056,-2.6e-05,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 -GHP-Heat-HIR-fRPM&OAT,GasHeat-Pump,BiQuadratic,,RPM,OAT,194.037,109.788263,15.50214113,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 -GHP-Heat-Waste-Heat-fEDB&OAT,GasHeat-Pump,BiLinear,QRatio,EDB,OAT,1,0,0,,,,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 -GHP-Heat-Waste-Heat-fRPM&OAT,GasHeat-Pump,BiQuadratic,QRatio,RPM,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 -GHP-Sens-Cap-fEWB&OAT,GasHeat-Pump,BiQuadratic,QRatio,EWB,OAT,1.49637568,0.079056576,-0.004212,-0.030189312,0.000157,0.00062,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -Glass Door Defrost Curve,Refrigerated Case,Cubic,,,,0.3475,0.0296,0.0007,3e-05,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings -Glass Door Latent Curve,Refrigerated Case,Cubic,,,,0.3379,0.0309,0.0005,4e-05,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings -GoodCyclingAC-EIR-fPLR,CyclingAC,Cubic,EIRRatio,PLR,,2.73e-06,1.05259,-0.0552087,0.00262236,,,,,,,,,,,,,From .dat files included with MASControl2 -GSHP/WLHP_BF_fAirflow-Old,GSHP/WLHPCurves,Cubic,QRatio,Airflow,,-0.828,14.3,-21.9,9.4,,,,,,,,,,,,,From .dat files included with MASControl2 -GSHP/WLHP_BF_fEwbEwt,GSHP/WLHPCurves,BiLinear,QRatio,EWB,EWT,-0.2016,0.0297,0.02646,,,,,,,,,,,,0.347365,1.67341,From .dat files included with MASControl2 -GSHP/WLHP_BF_fEwbEwt-Old,GSHP/WLHPCurves,BiQuadratic,QRatio,EWB,EWT,-5.522656,0.735768,-0.0185004,0.1418832,0.000943,-0.010206,,,,,,,,,,,From .dat files included with MASControl2 -GSHP/WLHP_Cool_Cap_fEwbEwt,GSHP/WLHPCurves,BiLinear,QRatio,EWB,EWT,0.88114368,0.015264,-0.007493418,,,,,,,,,,,,0.803411,1.18555,From .dat files included with MASControl2 -GSHP/WLHP_Cool_EIR_fEwbEwt,GSHP/WLHPCurves,BiLinear,EIRRatio,EWB,EWT,0.4111216,-0.00396,0.03011184,,,,,,,,,,,,0.300674,1.80627,From .dat files included with MASControl2 -GSHP/WLHP_H/C_EIR-fPLR,GSHP/WLHPCurves,Quadratic,EIRRatio,PLR,,0.0414,0.328,0.575337,,,,,,,,,,,,0,1,From .dat files included with MASControl2 -GSHP/WLHP_H/C_EIR-fPLR-Old,GSHP/WLHPCurves,Cubic,EIRRatio,PLR,,0.00988,1.08,-0.105,0.0151,,,,,,,,,,,,,From .dat files included with MASControl2 -GSHP/WLHP_Heat_Cap_fEdbEwt,GSHP/WLHPCurves,BiLinear,QRatio,EDB,EWT,1.07264,-0.003564,0.027,,,,,,,,,,,,0.966284,1.86368,From .dat files included with MASControl2 -GSHP/WLHP_Heat_EIR_fEdbEwt,GSHP/WLHPCurves,BiLinear,EIRRatio,EDB,EWT,0.59444,0.01908,-0.009774,,,,,,,,,,,,0.681922,1.10294,From .dat files included with MASControl2 -HeatSys1 Boiler Non-Condensing Boiler Curve,Boiler,Cubic,FIRRatio,QRatio,,0.626428326,0.645643582,-0.77720685,0.313806701,,,,,,,0.1,1,,,,,From Prototype Buildings -HeatWheel-EIR-fSpeed,ERVUnit,Linear,EIRRatio,Speed,,25.8,7.639437277,,,,,,,,,,,,,,,From .dat files included with MASControl2 -Herm-Cent-Cap-fCHWT&ECT,HermCentrifugal,BiQuadratic,QRatio,CHWT,ECT,0.257896,0.0389016,-0.000217,0.0468684,-0.000943,-0.000343,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Herm-Cent-EIR-fCHWT&ECT,HermCentrifugal,BiQuadratic,EIRRatio,CHWT,ECT,0.933884,-0.058212,0.00450036,0.00243,0.000486,-0.001215,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Herm-Cent-EIR-fPLR,HermCentrifugal,Quadratic,EIRRatio,PLR,,0.222903,0.313387,0.46371,,,,,,,,0,0.105,,,,,From .dat files included with MASControl2 -Herm-Rec-Cap-fCHWT&ECT,HermReciprocatg,BiQuadratic,QRatio,CHWT,ECT,0.507883,0.1452276,-0.00625644,-0.0011178,-0.00013,-0.000282,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Herm-Rec-EIR-fCHWT&ECT,HermReciprocatg,BiQuadratic,EIRRatio,CHWT,ECT,1.030757,-0.103536,0.00710208,0.0093186,0.000318,-0.00104,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Herm-Rec-EIR-fPLR,HermReciprocatg,Quadratic,EIRRatio,PLR,,0.088065,1.137742,-0.225806,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Hospital Kitchen_Flr_5_Case:1_WALKINFREEZERSingleShelfHorizontal_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.0236,0.0006,0,0,,,,,,,-35,20,,,,,From Prototype Buildings -Hospital Kitchen_Flr_5_Case:2_SELFCONTAINEDDISPLAYCASEMultiShelfVertical_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,6.02558e-05,1.23732e-06,,,,,,,-35,20,,,,,From Prototype Buildings -HotelLarge Kitchen_Flr_6_Case:1_WALKINFREEZERSingleShelfHorizontal_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.0236,0.0006,0,0,,,,,,,-35,20,,,,,From Prototype Buildings -HotelLarge Kitchen_Flr_6_Case:2_SELFCONTAINEDDISPLAYCASEMultiShelfVertical_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,6.02558e-05,1.23732e-06,,,,,,,-35,20,,,,,From Prototype Buildings -HP-Bypass-Factor-fAirflow,Water-LoopHP,Cubic,QRatio,Airflow,,-0.828,14.3,-21.9,9.4,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -HP-Bypass-Factor-fEWB&EWT,Water-LoopHP,BiQuadratic,QRatio,EWB,EWT,-5.522656,0.735768,-0.0185004,0.1418832,0.000943,-0.010206,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -HP-Cool-Cap-fEWB&EWT,Water-LoopHP,BiQuadratic,QRatio,EWB,EWT,0.38053696,0.041974272,-3.09e-05,-0.006642864,2.28e-05,-8.81e-05,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -HP-Cool-EIR-fEWB&EWT,Water-LoopHP,BiQuadratic,EIRRatio,EWB,EWT,1.3257696,-0.0504504,0.000988,0.02036448,7.91e-05,-0.000531,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -HP-Cool-EIR-fPLR,Water-LoopHP,Linear,EIRRatio,PLR,,0.125,0.875,,,,,,,,,,,,,,,From .dat files included with MASControl2 -HP-Heat-Cap-fEDB&EWT,Water-LoopHP,BiLinear,QRatio,EDB,EWT,0.72324,-0.012204,0.02538,,,,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -HP-Heat-EIR-fEDB&EWT,Water-LoopHP,BiLinear,EIRRatio,EDB,EWT,1.2124,0.01089,-0.02088,,,,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -HP-Heat-EIR-fPLR,Water-LoopHP,Cubic,EIRRatio,PLR,,0.0857,0.939,-0.183,0.15897022,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -HP-Sens-Cap-fAirflow,Water-LoopHP,Cubic,QRatio,Airflow,,-0.13,2.16,-1.6,0.573,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -HP-Sens-Cap-fEWB&EWT,Water-LoopHP,BiQuadratic,QRatio,EWB,EWT,1.68318464,0.012410496,-0.00215784,-0.009251064,6.32e-05,0.000174,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -HPACCoolCapFFF,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,, -HPACCoolCapFT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.766956,0.0107756,-4.14703e-05,0.00134961,-0.000261144,0.000457488,,,,,12.77778,23.88889,21.11111,46.11111,,, -HPACCOOLEIRFFF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.156,-0.1816,0.0256,,,,,,,,0.5,1.5,,,,, -HPACCOOLEIRFT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.297145,0.0430933,-0.000748766,0.00597727,0.000482112,-0.000956448,,,,,12.77778,23.88889,21.11111,46.11111,,, -HPACCOOLPLFFPLR,DX Cooling Coil,Quadratic,EIRRatio,QRatio,,0.85,0.15,0,,,,,,,,0,1,,,,, -HPACHeatCapFFF,DX Heating Coil,Cubic,QRatio,FlowRatio,,0.84,0.16,0,0,,,,,,,0.5,1.5,,,,,From Prototype Buildings -HPACHeatCapFT,DX Heating Coil,Cubic,QRatio,Toadb,,0.758746,0.027626,0.000148716,3.4992e-06,,,,,,,-20,20,,,,,From Prototype Buildings -HPACHeatEIRFFF,DX Heating Coil,Quadratic,EIRRatio,FlowRatio,,1.3824,-0.4336,0.0512,,,,,,,,0,1,,,,,From Prototype Buildings -HPACHeatEIRFT,DX Heating Coil,Cubic,EIRRatio,Toadb,,1.19248,-0.0300438,0.00103745,-2.3328e-05,,,,,,,-20,20,,,,,From Prototype Buildings -Htrec-Chlr-Cap-fCHWT&ECT,ElecHeatRecover,BiQuadratic,QRatio,CHWT,ECT,0.257896,0.0389016,-0.000217,0.0468684,-0.000943,-0.000343,,,,,4.44444,18.33333,12.77778,51.66667,,,From .dat files included with MASControl2 -Htrec-Chlr-EIR-fCHWT&ECT,ElecHeatRecover,BiQuadratic,EIRRatio,CHWT,ECT,0.933884,-0.058212,0.00450036,0.00243,0.000486,-0.001215,,,,,4.44444,18.33333,12.77778,51.66667,,,From .dat files included with MASControl2 -Htrec-Chlr-EIR-fPLR,ElecHeatRecover,Quadratic,EIRRatio,PLR,,0.349032,0.263871,0.387097,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Htrej-Fan-Pwr-fDamper,FluidCooler,Cubic,,Damper,,0.37607971,-0.21440694,1.00540793,-0.16712119,,,,,,,,,,,0.36,1,From .dat files included with MASControl2 -HW-Coil-Cap-fAirflow,HWCoils,Quadratic,QRatio,Airflow,,0.289,1.03,-0.317,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -HW-Coil-Cap-fdT,HWCoils,Quadratic,QRatio,dT,,-0.00467,1.8,0.010960272,,,,,,,,0,150,,,0.01,,From .dat files included with MASControl2 -HW-Coil-Cap-fFluidFlow,HWCoils,Quadratic,QRatio,FluidFlow,,0.18,2945.2432,-2540000,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Indirect-Effectiveness-fFlow,EvapCooler,Quadratic,,Flow,,1.1,-350,306000,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Inverter_EIR-fPLR,PV-Inverter,Quadratic,EIRRatio,PLR,,0.01677774,1.03766656,-0.05444431,,,,,,,,,,,,,,From .dat files included with MASControl2 -Large-CHW-Bypass-fAirflow,CHWCoils,Quadratic,QRatio,Airflow,,0.397,0.15,0.45374713,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Large-CHW-Coil-Bypass-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,0.435936,0.23652,-0.0047628,-0.1330272,0.00119556,0.000859,,,,,15.55556,29.44444,12.77778,29.44444,,,From .dat files included with MASControl2 -Large-CHW-Coil-Cap-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,0.09793216,-0.13886496,0.0124416,0.088907328,0.001938946,-0.009305604,,,,,15.55556,29.44444,12.77778,29.44444,,,From .dat files included with MASControl2 -Large-CHW-Sens-Cap-fAirflow,CHWCoils,Quadratic,QRatio,Airflow,,0.202,0.855,-0.057,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Large-CHW-Sens-Cap-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,0.12076864,-0.124558848,0.0063828,0.11146032,0.001847902,-0.006508285,,,,,15.55556,13.33333,12.77778,29.44444,,,From .dat files included with MASControl2 -Lp2Lp_Cap_fCHW&HWR,Loop2Loop,BiQuadratic,QRatio,CHWT,HWR,0.95122179,0.035393436,0.00027,-0.002654118,-8.69e-05,-0.000274,,,,,,,,,,,From .dat files included with MASControl2 -Lp2Lp_EIR_fCHW&HWR,Loop2Loop,BiQuadratic,EIRRatio,CHWT,HWR,0.59918703,-0.00950724,0.000335,0.00863883,0.000312,-0.000386,,,,,,,,,,,From .dat files included with MASControl2 -Lp2Lp-EIR-fPLR-1Comp/Ckt,Loop2Loop,Quadratic,EIRRatio,PLR,,0.03481113,0.95945376,0.00573495,,,,,,,,,,,,,,From .dat files included with MASControl2 -Lp2Lp-EIR-fPLR-2Comp/Ckt,Loop2Loop,Quadratic,EIRRatio,PLR,,0.02297712,0.90150452,0.07551826,,,,,,,,,,,,,,From .dat files included with MASControl2 -LT_compressor_capacity,Refrigeration,BiCubic,Capacity,Suction T,Discharge T,170751.834,6102.9037,78.2619862,-2959.4326,19.7876589,-90.958101,0.43596477,-0.0411577,-0.608846,0.459133262,-40,17.8,4.4,54.4,,,From AEDG -LT_compressor_power,Refrigeration,BiCubic,Power,Suction T,Discharge T,29669.2711,1027.63205,18.1066262,-442.19971,11.1335288,-20.380452,0.13998065,-0.0588669,-0.2184515,0.203858467,-40,-17.8,4.4,54.4,,,From AEDG -mc-Si_Spectral-fAirMass,PV-Module,Cubic,,AirMass,,0.96113414,0.02820018,-0.00134585,-0.00012036,,,,,,,,,,,,,From .dat files included with MASControl2 -Measured_CoolCStandard10Ton_EIRFFF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.192,-0.1917,0,,,,,,,,0.776,1.197,,,,,From PNNL Prototype FullServiceRestaurant -MNECB-CAP-FAPP&WB,CAP-FAPP&WB,BiQuadratic,QRatio,App,WB,-0.05425558,-0.063981648,0.026052289,0.260016714,0.000809093,0.015903767,,,,,,,,,,,From .dat files included with MASControl2 -MNECB-CAP-FRNG&WB,CAP-FRNG&WB,BiQuadratic,QRatio,Rng,WB,188.8588489,0.300231774,-0.045692003,35.40844622,0.601350934,0.78576062,,,,,,,,,,,From .dat files included with MASControl2 -MNECB-Centrif-CAP-FT,Centrif-CAP-FT,BiQuadratic,QRatio,T,T,0.70790824,-0.002006568,-0.00259605,0.030058776,-0.001056434,0.002045704,,,,,,,,,,,From .dat files included with MASControl2 -MNECB-Centrif-EIR-FPLR,Centrif-EIR-FPLR,Quadratic,EIRRatio,PLR,,0.17149273,0.58820208,0.23737257,,,,,,,,,,,,,,From .dat files included with MASControl2 -MNECB-Centrif-EIR-FT,Centrif-EIR-FT,BiQuadratic,EIRRatio,T,T,0.5605438,-0.01377927,6.57e-05,0.013219362,0.000268596,-0.000501131,,,,,,,,,,,From .dat files included with MASControl2 -MNECB-DW-HIR-fPLR,DHW-HIR,Quadratic,,PLR,,0.021826,0.97763,0.000543,,,,,,,,,,,,,,From .dat files included with MASControl2 -MNECB-HW-HIR-fPLR,HW-HIR,Quadratic,,PLR,,0.082597,0.996764,-0.079361,,,,,,,,,,,,,,From .dat files included with MASControl2 -MNECB-Recip-CAP-FT,Recip-CAP-FT,BiQuadratic,QRatio,T,T,1.0303123,0.033469794,0.00023639,-0.007295868,-2.32e-05,-0.000148943,,,,,,,,,,,From .dat files included with MASControl2 -MNECB-Recip-EIR-FPLR,Recip-EIR-FPLR,Quadratic,EIRRatio,PLR,,0.08144133,0.41927141,0.49939604,,,,,,,,,,,,,,From .dat files included with MASControl2 -MNECB-Recip-EIR-FT,Recip-EIR-FT,BiQuadratic,EIRRatio,T,T,0.49969897,-0.013084056,0.000266425,0.016592526,0.000185393,-0.000375646,,,,,,,,,,,From .dat files included with MASControl2 -Multi Shelf Vertical Latent Energy Multiplier,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,-6.02558e-05,1.23732e-06,,,,,,,-35,20,,,,,From Reference Buildings -Multi Zone VAV with Airfoil or Backward Incline riding the curve,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.1631,1.5901,-0.8817,0.1281,,,,,,,0,1,,,0.7,,From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method -Multi Zone VAV with Airfoil or Backward Incline with inlet vanes,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.9977,-0.659,0.9547,-0.2936,,,,,,,0,1,,,0.5,,From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method -Multi Zone VAV with Forward Curved fans riding the curve,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.1224,0.612,0.5983,-0.3334,,,,,,,0,1,,,0.3,,From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method -Multi Zone VAV with Forward Curved with inlet vanes,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.3038,-0.7608,2.2729,-0.8169,,,,,,,0,1,,,0.3,,From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method -Multi zone VAV with static pressure reset,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.040759894,0.08804497,-0.07292612,0.943739823,,,,,,,0,1,,,0.1,,"OpenStudio default, baseline for System Types 5-8 from ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method" -Multi Zone VAV with vane-axial with variable pitch blades,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.1639,-0.4016,1.9909,-0.7541,,,,,,,0,1,,,0.2,,From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method -Multi Zone VAV with VSD and fixed SP setpoint,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.0013,0.147,0.9506,-0.0998,,,,,,,0,1,,,0.2,,Appendix G baseline from ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method -New_Low_Temp_Comp_Cap_Curve,,BiCubic,,,,58336.861,1561.7435,6.6068129,-283.65007,-0.12023494,-12.495749,-0.11627856,0.002277001,-0.11814833,0.032839613,-40,-17.8,4.4,54.4,,, -New_Low_Temp_Comp_Pwr_Curve,,BiCubic,,,,6274.9904,61.390661,1.6208537,129.11279,0.87411617,1.9581173,0.030293311,0.005754678,0.004653957,-0.000749905,-40,-17.8,4.4,54.4,,, -New_Med_Temp_Comp_Cap_Curve,,BiCubic,,,,61412.175,1570.8519,13.533449,-500.19524,8.1639124,-3.6895385,0.054485574,-0.088096805,0.006381584,-0.037503058,-23.3,7.2,10,60,,, -New_Med_Temp_Comp_Pwr_Curve,,BiCubic,,,,4994.0336,170.24972,2.8463891,356.79403,-6.3074704,-1.409856,0.012160476,0.076231729,-0.057527471,0.009054446,-23.3,7.2,10,60,,, -No SP Reset VSD Fan,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.070428852,0.385330201,-0.460864118,1.00920344,,,,,,,0,1,,,0.1,,"From California Energy Commision, ""Advanced Variable Air Volume System Design Guide,"" October 2004" -Old_Low_Temp_Comp_Cap_Curve,,BiCubic,,,,170751.834,6102.9037,78.2619862,-2959.43265,19.7876589,-90.9581015,0.435964768,-0.041157653,-0.60884596,0.459133262,-40,-17.8,4.4,54.4,,, -Old_Low_Temp_Comp_Pwr_Curve,,BiCubic,,,,29669.2711,1027.63205,18.1066262,-442.199714,11.1335288,-20.3804519,0.139980653,-0.058866918,-0.218451538,0.203858467,-40,-17.8,4.4,54.4,,, -Old_Med_Temp_Comp_Cap_Curve,,BiCubic,,,,151166.436,5266.34789,60.6727151,-1851.55938,5.73132755,-46.9277173,0.136401203,-0.035697884,-0.403053994,-0.039290478,-23.3,7.2,10,60,,, -Old_Med_Temp_Comp_Pwr_Curve,,BiCubic,,,,7438.92229,-269.597565,-9.85610446,553.57326,-3.38588961,14.8657878,-0.100796292,0.009822793,0.097362356,-0.039675217,-23.3,7.2,10,60,,, -Open Latent Curve,Refrigerated Case,Cubic,,,,-0.0187,0.0458,0.0011,5e-05,,,,,,,-55,55,,,,,For SuperMarket Prototype Buildings -Open-Cent-Cap-fCHWT&ECT,OpenCentrifugal,BiQuadratic,QRatio,CHWT,ECT,0.257896,0.0389016,-0.000217,0.0468684,-0.000943,-0.000343,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Open-Cent-EIR-fCHWT&ECT,OpenCentrifugal,BiQuadratic,EIRRatio,CHWT,ECT,0.933884,-0.058212,0.00450036,0.00243,0.000486,-0.001215,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Open-Cent-EIR-fPLR,OpenCentrifugal,Quadratic,EIRRatio,PLR,,0.222903,0.313387,0.46371,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Open-Rec-Cap-fCHWT&ECT,OpenReciprocatg,BiQuadratic,QRatio,CHWT,ECT,0.507883,0.1452276,-0.00625644,-0.0011178,-0.00013,-0.000282,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Open-Rec-EIR-fCHWT&ECT,OpenReciprocatg,BiQuadratic,EIRRatio,CHWT,ECT,1.030757,-0.103536,0.00710208,0.0093186,0.000318,-0.00104,,,,,4.44444,18.33333,12.77778,46.11111,,,From .dat files included with MASControl2 -Open-Rec-EIR-fPLR,OpenReciprocatg,Quadratic,EIRRatio,PLR,,0.088065,1.137742,-0.225806,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -OpenTwr-FluidCap-fApp&WB,OpenTower,BiQuadratic,QRatio,App,WB,0.11735985,0.010588518,0.000701,0.052439526,0.000724,0.003437899,,,,,,,,,,,From .dat files included with MASControl2 -OpenTwr-FluidCap-fRng&WB,OpenTower,BiQuadratic,QRatio,Rng,WB,0.11661702,0.202450932,-0.004401443,-0.01592307,0.000101,-0.001101632,,,,,,,,,,,From .dat files included with MASControl2 -PoorCyclingAC-EIR-fPLR,CyclingAC,Cubic,EIRRatio,PLR,,0.000362523,1.32573,-0.407603,0.0818194,,,,,,,,,,,,,From .dat files included with MASControl2 -PSZ-AC DX Coil EIR-FT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.342414409,0.034885008,-0.0006237,0.004977216,0.000437951,-0.000728028,,,,,12.77778,23.88889,23.88889,46.11111,,,"From PNNL Prototype Buildings HotelSmall, Warehouse" -PSZ-AC DX Unitary Package EIRFT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.297145,0.0430933,-0.000748766,0.00597727,0.000482112,-0.000956448,,,,,12.77778,23.88889,21.11111,46.11111,,,"From PNNL Prototype Buildings RetailStandAlone, RetailStripMall,SchoolPrimary" -PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_CapFT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.42415,0.04426,-0.00042,0.00333,-8e-05,-0.00021,,,,,17,22,29,46,,,"From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" -PSZ-AC_CoolCLennoxStandard10Ton_TGA120S2B_PLR,DX Cooling Coil,Quadratic,EIRRatio,QRatio,,0.771,0.229,0,,,,,,,,0,1,,,,,"From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" -PSZ-AC_CoolCStandard10Ton_EIRFT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,1.23649,-0.02431,0.00057,-0.01434,0.00063,-0.00038,,,,,17,22,29,46,,,"From PNNL Prototype Buildings OutPatientHealtCare, RestaurantFastFood, RestaurantSitDown, SchoolPrimary, SchoolSecondary" -PSZ-AC_Unitary_PackagecoolCapFT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.766956,0.0107756,-4.14703e-05,0.00134961,-0.000261144,0.000457488,,,,,12.77778,23.88889,21.11111,46.11111,,,"From PNNL Prototype Buildings RetailStandalone, RetailStripMall, SchoolPrimary" -PSZ-AC_Unitary_PackagecoolEIRFFF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.156,-0.1816,0.0256,,,,,,,,0.5,1.5,,,,, -PSZ-AC_Unitary_PackagecoolFFF,DX Cooling Coil,Quadratic,QRatio,FlowRatio,,0.8,0.2,0,,,,,,,,0.5,1.5,,,,, -PSZ-AC_Unitary_PackagecoolPLR,DX Cooling Coil,Quadratic,EIRRatio,QRatio,,0.75,0.25,0,,,,,,,,0,1,,,,,"From PNNL Prototype Buildings RetailStandAlone, RetailStripMall, SchoolPrimary" -PSZ-AC:1_Unitary_PackagecoolEIRFFF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.156,-0.1816,0.0256,,,,,,,,0.5,1.5,,,,,"From PNNL Prototype Buildings RetailStandAlone, RetailStripMall, SchoolPrimary" -PSZ-Fine Storage DX Coil Cap-FT,DX Cooling Coil,BiQuadratic,QRatio,Twb,Toadb,0.942587793,0.009543347,0.00068377,-0.011042676,5.249e-06,-9.72e-06,,,,,12.77778,23.88889,23.88889,46.11111,,,"From PNNL Prototype Buildings HotelSmall, Warehouse" -PSZ-Fine Storage Heating Coil PLF-FPLR,DX Heating Coil,Cubic,EIRRatio,QRatio,,0.8,0.2,0,0,,,,,,,0,1,,,,,From Prototype Buildings -PSZ-Office Heating Coil PLF-FPLR,DX Heating Coil,Cubic,EIRRatio,QRatio,,0.8,0.2,0,0,,,,,,,0,1,,,,,From Prototype Buildings -PSZ135to240_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 -PSZ135to240_BF_fT,BF_fT,BiQuadratic,,T,T,43.269632,-4.898304,0.148392,0.0947376,0.00213192,-0.0134136,,,,,,,,,0,4.04,From .dat files included with MASControl2 -PSZ135to240_CEIR_fPLR,CEIR_fPLR,Cubic,EIRRatio,PLR,,0.0184,1.15,-0.208,0.0423,,,,,,,,,,,,,From .dat files included with MASControl2 -PSZ135to240_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.62774528,-0.060192,0.00260172,-0.005653656,2.66e-05,-0.00040824,,,,,,,,,,,From .dat files included with MASControl2 -PSZ135to240_CLoss_fPLR,CLoss_fPLR,Cubic,,PLR,,0.852,0.203,-0.0423,0.00938,,,,,,,,,,,0.8024,1.0728,From .dat files included with MASControl2 -PSZ135to240_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,0.4018688,0.1920384,-0.0077436,-0.01956816,-4.15e-05,0.00077436,,,,,,,,,,,From .dat files included with MASControl2 -PSZ135to240_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,-0.0449056,0.07059456,-0.00216432,0.00440856,0.00041148,-0.000245916,,,,,,,,,,,From .dat files included with MASControl2 -PSZ135to240_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 -PSZ135to240_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 -PSZ240to760_BF_fFlow,BF_fFlow,Linear,QRatio,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 -PSZ240to760_BF_fT,BF_fT,BiQuadratic,,T,T,15.8724544,-1.6604928,0.041148,0.03013992,0.000278964,0.00047628,,,,,,,,,0,3.252,From .dat files included with MASControl2 -PSZ240to760_CEIR_fPLR,CEIR_fPLR,Cubic,EIRRatio,PLR,,2.63,-9.5,14.3,-6.4,,,,,,,,,,,,,From .dat files included with MASControl2 -PSZ240to760_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.27910208,-0.0291096,0.00167184,-0.002266416,-3.1e-05,-0.00033372,,,,,,,,,,,From .dat files included with MASControl2 -PSZ240to760_CLoss_fPLR,CLoss_fPLR,Cubic,,PLR,,0.964,0.289,0.183,-0.131,,,,,,,,,,,0.96,1.3,From .dat files included with MASControl2 -PSZ240to760_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.64083712,-0.06152112,-0.0004698,-0.010834704,-2.89e-05,0.000222912,,,,,,,,,,,From .dat files included with MASControl2 -PSZ240to760_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.336608,0.0487944,-0.00116316,-0.005994,0.00067716,-0.00069012,,,,,,,,,,,From .dat files included with MASControl2 -PSZ240to760_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 -PSZ240to760_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 -PSZ65to135_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 -PSZ65to135_BF_fT,BF_fT,BiQuadratic,,T,T,14.931264,-1.5724512,0.04698,0.0015984,0.00096552,-0.00319788,,,,,,,,,0,3.509,From .dat files included with MASControl2 -PSZ65to135_CEIR_fPLR,CEIR_fPLR,Cubic,EIRRatio,PLR,,0.0184,1.15,-0.208,0.0423,,,,,,,,,,,,,From .dat files included with MASControl2 -PSZ65to135_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.2518496,-0.02766672,0.00115344,0.0035388,-0.000134136,-0.000167508,,,,,,,,,,,From .dat files included with MASControl2 -PSZ65to135_CLoss_fPLR,CLoss_fPLR,Cubic,,PLR,,0.882,0.211,-0.0439,0.0098,,,,,,,,,,,0.8323,1.1087,From .dat files included with MASControl2 -PSZ65to135_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.7733472,0.0383688,-0.0038556,-0.01090224,-0.000138348,0.00070632,,,,,,,,,,,From .dat files included with MASControl2 -PSZ65to135_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.5431072,0.03102048,-0.00090072,-0.01496592,0.0006966,-0.000199908,,,,,,,,,,,From .dat files included with MASControl2 -PSZ65to135_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 -PSZ65to135_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 -PTAC_EIR_fPLR,PkgdTerminalACS,Cubic,EIRRatio,PLR,,0.125,0.875,0,0,,,,,,,,,,,,,From .dat files included with MASControl2 -PTAC-Bypass-Factor-fAirflow,PkgdTerminalAC,Quadratic,QRatio,Airflow,,-2.28,5.21,-1.93,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -PTAC-Bypass-Factor-fEWB&EDB,PkgdTerminalAC,BiQuadratic,QRatio,EWB,EDB,-0.219664,0.0994608,0.00102,-0.020394,0.00036,-0.00120528,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -PTAC-Cool-Cap-fEWB&OAT,PkgdTerminalAC,BiQuadratic,QRatio,EWB,OAT,0.93865088,0.0095364,0.000684,-0.011038176,5.25e-06,-9.72e-06,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -PTAC-EIR-fEWB&OAT,PkgdTerminalAC,BiQuadratic,EIRRatio,EWB,OAT,0.34208928,0.03484368,-0.000625,0.004968864,0.000438,-0.000728,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -PTAC-EIR-fPLR,PkgdTerminalAC,Linear,EIRRatio,PLR,,0.125,0.875,,,,,,,,,,,,,,,From .dat files included with MASControl2 -PTAC-Sens-Cap-fAirflow,PkgdTerminalAC,Linear,QRatio,Airflow,,0.6,0.4,,,,,,,,,,,,,,,From .dat files included with MASControl2 -PTAC-Sens-Cap-fEWB&OAT,PkgdTerminalAC,BiQuadratic,QRatio,EWB,OAT,3.2722656,-0.14984352,0.00140292,0.0047124,-0.000162,0.000207,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -PTACHPACEIRFT,DX Cooling Coil,BiQuadratic,EIRRatio,Twb,Toadb,0.342414409,0.034885008,-0.0006237,0.004977216,0.000437951,-0.000728028,,,,,12.77778,23.88889,18.3,46.11111,,,From DOE Reference Buildings SmallHotel -Pump-Head-fFlow,Pumps,Quadratic,QRatio,Flow,,1.3534831,33.8,-1660000,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Pump-Power-fFlow,Pumps,Quadratic,,Flow,,0.3697739,1780.65378,-943000,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -PVV240to760_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 -PVV240to760_BF_fT,BF_fT,BiQuadratic,,T,T,8.747712,-1.2544704,0.034992,0.219888,-0.00221292,-0.00284796,,,,,,,,,0,3.2,From .dat files included with MASControl2 -PVV240to760_CEIR_fPLR,CEIR_fPLR,Cubic,EIRRatio,PLR,,0.124,0.376,1.29,-0.794,,,,,,,,,,,,,From .dat files included with MASControl2 -PVV240to760_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,0.9521152,-0.01097712,0.0012312,-0.00072792,-4.54e-05,-0.000173988,,,,,,,,,,,From .dat files included with MASControl2 -PVV240to760_CLoss_fPLR,CLoss_fPLR,Cubic,,PLR,,0,1,0,0,,,,,,,,,,,0.1,1,From .dat files included with MASControl2 -PVV240to760_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.91654848,0.0047736,-0.00233604,-0.013756896,-3.23e-05,0.00057672,,,,,,,,,,,From .dat files included with MASControl2 -PVV240to760_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.380192,0.0241488,-0.00047952,0.0111168,0.00052488,-0.00102384,,,,,,,,,,,From .dat files included with MASControl2 -PVV240to760_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 -PVV240to760_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,,,,,,,From .dat files included with MASControl2 -PVVT-Bypass-Factor-fAirflow,PkgdVVVT,Quadratic,QRatio,Airflow,,-0.254,1.22,0.036,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -PVVT-Bypass-Factor-fEWB&EDB,PkgdVVVT,BiQuadratic,QRatio,EWB,EDB,0.85028352,0.014256792,0.000184,-0.014791716,-5.48e-06,0.000487,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -PVVT-Cool-Cap-fEWB&OAT,PkgdVVVT,BiQuadratic,QRatio,EWB,OAT,0.86783424,0.014239008,0.000554,-0.007558056,3.3e-05,-0.000192,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -PVVT-Cool-EIR-fEWB&OAT,PkgdVVVT,BiQuadratic,EIRRatio,EWB,OAT,0.1210048,0.0285336,-0.000411,0.02134944,0.000161,-0.00068,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -PVVT-Cool-EIR-fPLR,PkgdVVVT,Cubic,EIRRatio,PLR,,0.201,-0.0312,1.9504979,-1.1205104,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -PVVT-Heat-Cap-fEDB&OAT,PkgdVVVT,BiQuadratic,QRatio,EDB,OAT,0.74200928,0,0,0.030668544,3.23e-05,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 -PVVT-Heat-EIR-fEDB&OAT,PkgdVVVT,BiQuadratic,EIRRatio,EDB,OAT,1.255664,0,0,-0.0399528,0.00108864,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 -PVVT-Heat-EIR-fPLR,PkgdVVVT,Cubic,EIRRatio,PLR,,0.0857,0.939,-0.183,0.159,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -PVVT-Sens-Cap-fEWB&OAT,PkgdVVVT,BiQuadratic,QRatio,EWB,OAT,2.93229888,-0.09445968,0.0002,-0.007173756,1.03e-05,0.000109,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -Rcmp-kW-f-Tc-T1-Hi-Eff,Refrigeration,Quadratic,,Tc,,0.635620298,0.003533521,0.000161,,,,,,,,,,,,0.7533,1.2802,From .dat files included with MASControl2 -Rcmp-kW-f-Tc-T1-Low-Eff,Refrigeration,Quadratic,,Tc,,1.113461,-0.0308988,0.000739,,,,,,,,,,,,0.950084,1.606833,From .dat files included with MASControl2 -Rcmp-kW-f-Tc-T2-Hi-Eff,Refrigeration,Quadratic,,Tc,,0.580834119,0.00494838,0.000161,,,,,,,,,,,,0.7262,1.3046,From .dat files included with MASControl2 -Rcmp-kW-f-Tc-T2-Low-Eff,Refrigeration,Quadratic,,Tc,,0.970164,-0.02268,0.000625,,,,,,,,,,,,0.943908,1.565353,From .dat files included with MASControl2 -Rcmp-kW-f-Tc-T3-Hi-Eff,Refrigeration,Quadratic,,Tc,,0.358796196,0.007319986,0.000257,,,,,,,,,,,,0.5728,1.4917,From .dat files included with MASControl2 -Rcmp-kW-f-Tc-T3-Low-Eff,Refrigeration,Quadratic,,Tc,,0.656539,-0.0039924,0.00035,,,,,,,,,,,,0.941987,1.418136,From .dat files included with MASControl2 -Rcmp-kW2-f-Tc-T1-Hi-Eff,Refrigeration,Quadratic,,Tc,,0.904478102,-0.008972199,0.000303,,,,,,,,,,,,0.8518,1.2802,From .dat files included with MASControl2 -Rcmp-kW2-f-Tc-T1-Low-Eff,Refrigeration,Quadratic,,Tc,,1.113461,-0.0308988,0.000739,,,,,,,,,,,,0.950084,1.606833,From .dat files included with MASControl2 -Rcmp-kW2-f-Tc-T2-Hi-Eff,Refrigeration,Quadratic,,Tc,,0.887325182,-0.009516488,0.000328,,,,,,,,,,,,0.8326,1.3046,From .dat files included with MASControl2 -Rcmp-kW2-f-Tc-T2-Low-Eff,Refrigeration,Quadratic,,Tc,,0.970164,-0.02268,0.000625,,,,,,,,,,,,0.943908,1.565353,From .dat files included with MASControl2 -Rcmp-kW2-f-Tc-T3-Hi-Eff,Refrigeration,Quadratic,,Tc,,0.829593266,-0.014865914,0.000512,,,,,,,,,,,,0.7434,1.4917,From .dat files included with MASControl2 -Rcmp-kW2-f-Tc-T3-Low-Eff,Refrigeration,Quadratic,,Tc,,0.656539,-0.0039924,0.00035,,,,,,,,,,,,0.941987,1.418136,From .dat files included with MASControl2 -Rcond-Fan-Pwr-fPLR-ACpress,Refrigeration,Linear,,PLR,,0,1,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 -Rcond-Fan-Pwr-fPLR-Damper,Refrigeration,Linear,,PLR,,0.3,0.7,,,,,,,,,,,,,0.3,1,From .dat files included with MASControl2 -RecipAir-Cap-fCHWT&DBT,HermReciprocatg,BiQuadratic,QRatio,CHWT,DBT,1.10674018,0.040197888,0.000286,-0.009552852,5.22e-06,-0.000255,,,,,,,,,,,From .dat files included with MASControl2 -RecipAir-EIR-fCHWT&DBT,HermReciprocatg,BiQuadratic,EIRRatio,CHWT,DBT,0.53866251,-0.008142246,0.000125,0.011090538,0.000164,-0.000342,,,,,,,,,,,From .dat files included with MASControl2 -RecipAir-EIR-fPLR-1Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.03892594,1.07531738,-0.10724027,-0.001050714,9.43e-06,0.000536346,,,,,,,,,,,From .dat files included with MASControl2 -RecipAir-EIR-fPLR-2Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.04812248,0.69573414,0.2349389,0.000819378,-3.86e-06,3.79e-05,,,,,,,,,,,From .dat files included with MASControl2 -RecipAir-EIR-fPLR-3Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.03296722,0.57721251,0.33923307,0.002786436,-3.11e-05,-0.000119,,,,,,,,,,,From .dat files included with MASControl2 -RecipAir-EIR-fPLR-4Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.00434876,0.61917436,0.32643354,0.003223368,-3.33e-05,-0.000514206,,,,,,,,,,,From .dat files included with MASControl2 -RecipH2O-Cap-fCHWT&ECT,HermReciprocatg,BiQuadratic,QRatio,CHWT,ECT,1.0689798,0.036781398,0.000334,-0.010426122,2.17e-05,-0.000208,,,,,,,,,,,From .dat files included with MASControl2 -RecipH2O-EIR-fCHWT&ECT,HermReciprocatg,BiQuadratic,EIRRatio,CHWT,ECT,0.51329254,-0.015039378,0.000362,0.015398694,0.000228,-0.000409,,,,,,,,,,,From .dat files included with MASControl2 -RecipH2O-EIR-fPLR&dT-1Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,-0.0142974,0.95360994,0.01805304,0.002822994,-1.99e-05,-0.000497988,,,,,,,,,,,From .dat files included with MASControl2 -RecipH2O-EIR-fPLR&dT-2Comp/Ckt,HermReciprocatg,BiQuadratic,EIRRatio,PLR,dT,0.02391765,0.88946915,0.07793053,-0.000474426,2.33e-05,0.000324,,,,,,,,,,,From .dat files included with MASControl2 -RecipRemote-Cap-fCHWT&SCT,HermReciprocatg,BiQuadratic,QRatio,CHWT,SCT,1.27977199,0.051393222,0.000332,-0.009522792,-1.97e-05,-0.000269,,,,,,,,,,,From .dat files included with MASControl2 -RecipRemote-EIR-fCHWT&SCT,HermReciprocatg,BiQuadratic,EIRRatio,CHWT,SCT,0.25314951,-0.015358788,0.000506,0.009717714,0.000171,-0.000382,,,,,,,,,,,From .dat files included with MASControl2 -RecipRemote-EIR-fPLR-1Comp/Ckt,HermReciprocatg,Quadratic,EIRRatio,PLR,,0.03521065,0.93266129,0.03212802,,,,,,,,,,,,,,From .dat files included with MASControl2 -RecipRemote-EIR-fPLR-2Comp/Ckt,HermReciprocatg,Quadratic,EIRRatio,PLR,,0.02511026,0.8934145,0.08147529,,,,,,,,,,,,,,From .dat files included with MASControl2 -Refg-Condenser-Cap-fCondT&WBT,Refrigeration,BiQuadratic,QRatio,CondT,WBT,0.15373327,0.00942813,0.000693,-0.020963196,-0.000702,0.000302,,,,,,,,,0.2,2.222,From .dat files included with MASControl2 -Refg-kW-fECT-T1,Refrigeration,Quadratic,,ECT,,0.753416,-0.0212148,0.000739,,,,,,,,,,,,0.850358,1.747334,From .dat files included with MASControl2 -Refg-kW-fECT-T2,Refrigeration,Quadratic,,ECT,,1.00323,-0.0290574,0.000765,,,,,,,,,,,,0.859029,1.592964,From .dat files included with MASControl2 -Refg-kW-fECT-T3,Refrigeration,Quadratic,,ECT,,0.671617,-0.0074358,0.000424,,,,,,,,,,,,0.873079,1.466883,From .dat files included with MASControl2 -Refg-kW-fPLR,Refrigeration,Quadratic,,PLR,,0.0383,1.08,-0.116129,,,,,,,,,,,,0.1,1.2,From .dat files included with MASControl2 -Refg-kW2-fECT-T1,Refrigeration,Quadratic,,ECT,,0.753416,-0.0212148,0.000739,,,,,,,,,,,,0.850358,1.747334,From .dat files included with MASControl2 -Refg-kW2-fECT-T2,Refrigeration,Quadratic,,ECT,,1.00323,-0.0290574,0.000765,,,,,,,,,,,,0.859029,1.592964,From .dat files included with MASControl2 -Refg-kW2-fECT-T3,Refrigeration,Quadratic,,ECT,,0.671617,-0.0074358,0.000424,,,,,,,,,,,,0.873079,1.466883,From .dat files included with MASControl2 -Residential Fix Vol-Fan EIR,FanEIR-FPLR,Linear,EIRRatio,PLR,,1,0,,,,,,,,,,,,,,,From .dat files included with MASControl2 -Residential Var Vol-Fan EIR,FanEIR-FPLR,Cubic,EIRRatio,PLR,,0.000281,-0.0579,0.586,0.471,,,,,,,,,,,,,From .dat files included with MASControl2 -RestaurantFastFood Kitchen_Case:1_WALKINFREEZERSingleShelfHorizontal_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.0236,0.0006,0,0,,,,,,,-35,20,,,,,From Prototype Buildings -RestaurantFastFood Kitchen_Case:2_SELFCONTAINEDDISPLAYCASEMultiShelfVertical_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,6.02558e-05,1.23732e-06,,,,,,,-35,20,,,,,From Prototype Buildings -RESVVT-Bypass-Factor-fAirflow,ResidentialVVVT,Quadratic,QRatio,Airflow,,-0.254,1.22,0.036,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -RESVVT-Bypass-Factor-fEWB&EDB,ResidentialVVVT,BiQuadratic,QRatio,EWB,EDB,0.85086272,0.014256792,0.000184,-0.014759136,-5.48e-06,0.000487,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -RESVVT-Cool-Cap-fEWB&OAT,ResidentialVVVT,BiQuadratic,QRatio,EWB,OAT,0.47523136,0.04006368,0.000226,-0.000847152,-7.32e-06,-0.000447,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -RESVVT-Cool-Cap-fRPM&OAT,ResidentialVVVT,BiQuadratic,QRatio,RPM,OAT,-686.394,-427.2546283,-66.38563967,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 -RESVVT-Cool-CondFan-fPLR&OAT,ResidentialVVVT,BiQuadratic,,PLR,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 -RESVVT-Cool-CycleLoss-fPLR,ResidentialVVVT,Linear,QRatio,PLR,,0.7,0.3,,,,,,,,,,,,,,,From .dat files included with MASControl2 -RESVVT-Cool-EIR-fEWB&OAT,ResidentialVVVT,BiQuadratic,EIRRatio,EWB,OAT,0.63153792,-0.012168288,0.000509,0.015536304,0.000273,-0.000679,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -RESVVT-Cool-EIR-fPLR,ResidentialVVVT,Linear,EIRRatio,PLR,,0,1,,,,,,,,,,,,,,,From .dat files included with MASControl2 -RESVVT-Cool-EIR-fRPM&OAT,ResidentialVVVT,BiQuadratic,EIRRatio,RPM,OAT,35.1027,10.50422626,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 -RESVVT-Cool-EIR-LoSpeed-fEWB&OAT,ResidentialVVVT,BiQuadratic,EIRRatio,EWB,OAT,0.77672128,-0.034271136,0.000784,0.01465956,0.000489,-0.000752,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -RESVVT-Cool-Waste-Heat-fEWB&OAT,ResidentialVVVT,BiLinear,QRatio,EWB,OAT,1,0,0,,,,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -RESVVT-Cool-Waste-Heat-fRPM&OAT,ResidentialVVVT,BiQuadratic,QRatio,RPM,OAT,1,0,0,0,0,0,,,,,0,1.05,12.77778,46.11111,,,From .dat files included with MASControl2 -RESVVT-Heat-Cap-fEDB&OAT,ResidentialVVVT,BiQuadratic,QRatio,EDB,OAT,0.7716,0,0,0.02754,0,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 -RESVVT-Heat-Cap-fRPM&OAT,ResidentialVVVT,BiQuadratic,QRatio,RPM,OAT,-483.189,-303.9732093,-47.69188125,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 -RESVVT-Heat-CondFan-fPLR&OAT,ResidentialVVVT,BiQuadratic,,PLR,OAT,1,0,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 -RESVVT-Heat-CycleLoss-fPLR,ResidentialVVVT,Linear,QRatio,PLR,,0.75,0.25,,,,,,,,,,,,,,,From .dat files included with MASControl2 -RESVVT-Heat-EIR-fEDB&OAT,ResidentialVVVT,BiQuadratic,EIRRatio,EDB,OAT,1.1544,0,0,-0.02448,0.000729,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 -RESVVT-Heat-EIR-fPLR,ResidentialVVVT,Linear,EIRRatio,PLR,,0,1,,,,,,,,,,,,,,,From .dat files included with MASControl2 -RESVVT-Heat-EIR-fRPM&OAT,ResidentialVVVT,BiQuadratic,EIRRatio,RPM,OAT,31.9068,9.520648707,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 -RESVVT-Heat-EIR-LoSpeed-fEDB&OAT,ResidentialVVVT,BiQuadratic,EIRRatio,EDB,OAT,1.25435136,0,0,-0.040685472,0.001209784,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 -RESVVT-Heat-Waste-Heat-fEDB&OAT,ResidentialVVVT,BiLinear,QRatio,EDB,OAT,1,0,0,,,,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 -RESVVT-Heat-Waste-Heat-fRPM&OAT,ResidentialVVVT,BiQuadratic,QRatio,RPM,OAT,1,0,0,0,0,0,,,,,0,1.05,-23.33333,29.44444,,,From .dat files included with MASControl2 -RESVVT-Sens-Cap-fEWB&OAT,ResidentialVVVT,BiLinear,QRatio,EWB,OAT,2.78672,-0.08208,-0.005292,,,,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -RESYS-Bypass-Factor-fAirflow,Residential#1,Quadratic,QRatio,Airflow,,-3.01,6.59,-2.57,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -RESYS-Bypass-Factor-fEWB&EDB,Residential#1,BiQuadratic,QRatio,EWB,EDB,-1.1641344,0.20453184,-0.000603,-0.03036096,0.00036,-0.001464804,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -RESYS-Bypass-Factor-fPLR,ResidentialVVVT,Linear,QRatio,PLR,,1,0,,,,,,,,,,,,,,,From .dat files included with MASControl2 -RESYS-Cool-Cap-fEWB&OAT,Residential#1,BiQuadratic,QRatio,EWB,OAT,0.7665024,0.01076904,-4.15e-05,0.00133848,-0.000261,0.000457,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -RESYS-Cool-EIR-fEWB&OAT,Residential#1,BiQuadratic,EIRRatio,EWB,OAT,0.29770688,0.04314528,-0.000748,0.005972688,0.000482,-0.000956,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -RESYS-Cool-EIR-fPLR,,Cubic,EIRRatio,PLR,,6.26e-05,1.18,-0.202,0.0263344,,,,,,,,,,,,,From .dat files included with MASControl2 -RESYS-Heat-Cap-fEDB&OAT,Residential#1,BiQuadratic,QRatio,EDB,OAT,0.7516064,0,0,0.02799072,0.00019,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 -RESYS-Heat-EIR-fEDB&OAT,Residential#1,BiQuadratic,EIRRatio,EDB,OAT,1.231072,0,0,-0.0334944,0.000739,0,,,,,7.22222,29.44444,-23.33333,29.44444,,,From .dat files included with MASControl2 -RESYS-Heat-EIR-fPLR,Residential#1,Cubic,EIRRatio,PLR,,0.0857,0.939,-0.1834361,0.15897022,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -RESYS-Sens-Cap-fAirflow,Residential#1,Linear,QRatio,Airflow,,0.6,0.4,,,,,,,,,,,,,,,From .dat files included with MASControl2 -RESYS-Sens-Cap-fEWB&OAT,Residential#1,BiQuadratic,QRatio,EWB,OAT,3.3127968,-0.1617552,0.00184356,0.01027584,-0.000156,-2.84e-05,,,,,12.77778,29.44444,21.11111,46.11111,,,From .dat files included with MASControl2 -SAC Heating Coil PLF-FPLR,DX Heating Coil,Cubic,EIRRatio,QRatio,,0.8,0.2,0,0,,,,,,,0,1,,,,,From Prototype Buildings -SchoolPrimary Kitchen_ZN_1_FLR_1_Case:1_WALKINFREEZERSingleShelfHorizontal_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.0236,0.0006,0,0,,,,,,,-35,20,,,,,From Prototype Buildings -SchoolPrimary Kitchen_ZN_1_FLR_1_Case:2_SELFCONTAINEDDISPLAYCASEMultiShelfVertical_LatentEnergyMult,Refrigerated Case,Cubic,,,,0.026526281,0.001078032,6.02558e-05,1.23732e-06,,,,,,,-35,20,,,,,From Prototype Buildings -ScrewAir-Cap-fCHWT&DBT,Screw,BiQuadratic,QRatio,CHWT,DBT,0.97878647,0.02387169,0.000587,-4.78e-05,-0.000112,-0.00011,,,,,,,,,,,From .dat files included with MASControl2 -ScrewAir-EIR-fCHWT&DBT,Screw,BiQuadratic,EIRRatio,CHWT,DBT,0.6729704,-0.005730012,0.000702,-0.00119601,0.00044,-0.000699,,,,,,,,,,,From .dat files included with MASControl2 -ScrewAir-EIR-fPLR&dT-1Comp/Ckt,Screw,BiQuadratic,EIRRatio,PLR,dT,0.01040687,1.05183303,-0.09462459,0.002943774,-2.52e-05,-0.001085832,,,,,,,,,,,From .dat files included with MASControl2 -ScrewAir-EIR-fPLR&dT-2Comp/Ckt,Screw,BiQuadratic,EIRRatio,PLR,dT,0.09611014,0.72898877,0.19517007,-0.000729072,6.67e-06,-0.000175,,,,,,,,,,,From .dat files included with MASControl2 -ScrewH2O-Cap-fCHWT&ECT,Screw,BiQuadratic,QRatio,CHWT,ECT,1.07096667,0.02693502,0.000768,-0.00643302,-9.49e-05,-6.59e-05,,,,,,,,,,,From .dat files included with MASControl2 -ScrewH2O-EIR-fCHWT&ECT,Screw,BiQuadratic,EIRRatio,CHWT,ECT,0.59849788,-0.00123345,0.000563,0.001602738,0.000636,-0.001094148,,,,,,,,,,,From .dat files included with MASControl2 -ScrewH2O-EIR-fPLR&dT-1Comp/Ckt,Screw,BiQuadratic,EIRRatio,PLR,dT,-0.11699212,1.2635448,-0.2194667,0.005301648,5.47e-05,-0.003346506,,,,,,,,,,,From .dat files included with MASControl2 -ScrewH2O-EIR-fPLR&dT-2Comp/Ckt,Screw,BiQuadratic,EIRRatio,PLR,dT,-0.27111483,1.49009538,-0.33198115,0.017556084,-0.000191,-0.008247186,,,,,,,,,,,From .dat files included with MASControl2 -ScrewRemote-Cap-fCHWT&SCT,Screw,BiQuadratic,QRatio,CHWT,SCT,1.16410009,0.048370122,0.000493,-0.002428218,-0.000109,-0.000269,,,,,,,,,,,From .dat files included with MASControl2 -ScrewRemote-EIR-fCHWT&SCT,Screw,BiQuadratic,EIRRatio,CHWT,SCT,0.79518287,-0.009101466,0.001707804,-0.015352632,0.000488,-0.000932,,,,,,,,,,,From .dat files included with MASControl2 -ScrewRemote-EIR-fPLR-1Comp/Ckt,Screw,Quadratic,EIRRatio,PLR,,0.07043035,1.01683199,-0.08726242,,,,,,,,,,,,,,From .dat files included with MASControl2 -ScrewRemote-EIR-fPLR-2Comp/Ckt,Screw,Quadratic,EIRRatio,PLR,,0.08138224,0.72724819,0.19136968,,,,,,,,,,,,,,From .dat files included with MASControl2 -ScrollChlrAirCoolCap-fCHW&OAT,Chiller,BiQuadratic,QRatio,CHWT,OAT,1.05229229,0.033560892,0.000215,-0.005180832,-4.42e-05,-0.000215,,,,,,,,,,,From .dat files included with MASControl2 -ScrollChlrAirCoolEIR-fCHW&OAT,Chiller,BiQuadratic,EIRRatio,CHWT,OAT,0.58333562,-0.004036194,0.000468,-0.000224478,0.000481,-0.000682,,,,,,,,,,,From .dat files included with MASControl2 -ScrollChlrAirCoolEIR-fPLR,Chiller,Quadratic,EIRRatio,PLR,,0.03366649,0.53152555,0.43480802,,,,,,,,,,,,,,From .dat files included with MASControl2 -Si-Film_Spectral-fAirMass,PV-Module,Cubic,,AirMass,,0.95691782,0.04079713,-0.00869376,0.00042887,,,,,,,,,,,,,From .dat files included with MASControl2 -Single Shelf Horizontal Latent Energy Multiplier_After2004,Refrigerated Case,Cubic,,,,0.0236,0.0006,0,0,,,,,,,-35,20,,,,,From Reference Buildings -Single Shelf Horizontal Latent Energy Multiplier_Pre2004,Refrigerated Case,Cubic,,,,0.020376,0.00024378,1.14e-05,1.811e-07,,,,,,,-35,20,,,,,From Reference Buildings -Single zone VAV fan,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.027827882,0.026583195,-0.0870687,1.03091975,,,,,,,0,1,,,0.1,,Baseline for System Type 11 from ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method -Small-CHW-Bypass-fAirflow,CHWCoils,Quadratic,QRatio,Airflow,,-0.718,1.91,-0.189,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Small-CHW-Coil-Bypass-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,1.09657216,0.001908,0.000369,-0.005647032,2.46e-05,-0.000277,,,,,15.55556,29.44444,12.77778,29.44444,,,From .dat files included with MASControl2 -Small-CHW-Coil-Cap-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,-0.282048,-0.022212,0.0054432,0.0297216,0.000804,-0.0033372,,,,,15.55556,29.44444,12.77778,29.44444,,,From .dat files included with MASControl2 -Small-CHW-Sens-Cap-fAirflow,CHWCoils,Quadratic,QRatio,Airflow,,0.155,1.01,-0.16,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Small-CHW-Sens-Cap-fEWB&EDB,CHWCoils,BiQuadratic,QRatio,EWB,EDB,-0.415152,-0.0405576,0.00140616,0.086508,0.000444,-0.00184356,,,,,12.77778,29.44444,12.77778,29.44444,,,From .dat files included with MASControl2 -Smooth_Optical-fAOI,PV-Module,Cubic,,AOI,,3.76248479,-0.15946805,0.00302191,-1.91e-05,,,,,,,,,,,,,From .dat files included with MASControl2 -Split DX Coil EIR-FF,DX Cooling Coil,Quadratic,EIRRatio,FlowRatio,,1.1552,-0.1808,0.0256,,,,,,,,0.5,1.5,,,,,"From PNNL Prototype Buildings ApartmentMidRise, HotelSmall, Warehouse" -SpltAC1Sp_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 -SpltAC1Sp_BF_fT,BF_fT,BiQuadratic,,T,T,8.513632,-0.630072,0.0165888,-0.0450144,0.00107892,-0.0018954,,,,,,,,,0,3.33,From .dat files included with MASControl2 -SpltAC1Sp_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,7e-05,1.23,-0.307,0.0756,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,0.00012,1.2,-0.261,0.0596,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-7e-05,1.17,-0.213,0.0438,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,0.67916,0.016938,0.00069336,0.0045576,-8.42e-05,-0.00047628,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC1Sp_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.805,0.233,-0.038,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.827,0.203,-0.03,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.852,0.17,-0.0219,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.7311616,-0.10297296,0.00093636,0.00477864,-9.07e-05,-0.000202824,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.7390464,-0.00778968,0.000128304,-0.00027,0.0006642,-0.000648,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC1Sp_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC1Sp_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC1Sp-ge45_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 -SpltAC1Sp-ge45_BF_fT,BF_fT,BiQuadratic,,T,T,16.900064,-1.747584,0.050544,0.1428912,0.00048924,-0.0090396,,,,,,,,,0,3.76,From .dat files included with MASControl2 -SpltAC1Sp-ge45_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0,1.18,-0.223,0.0468,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-ge45_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,8e-05,1.15,-0.183,0.0343,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-ge45_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.0001,1.12,-0.14,0.0225,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-ge45_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.2403136,-0.0346752,0.00187596,0.00106848,-5.7e-05,-0.0003564,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC1Sp-ge45_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.847,0.177,-0.0235,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-ge45_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.869,0.149,-0.0172,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-ge45_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.893,0.118,-0.0112,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-ge45_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.8260768,0.0199944,-0.00284148,-0.01422576,-5.77e-05,0.00064152,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-ge45_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.093776,0.0674784,-0.00192132,-0.0031176,0.00067068,-0.0005832,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC1Sp-ge45_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC1Sp-ge45_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC1Sp-lt45_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 -SpltAC1Sp-lt45_BF_fT,BF_fT,BiQuadratic,,T,T,22.932224,-2.291616,0.063504,0.0800712,0.00076464,-0.0068364,,,,,,,,,0,3.3,From .dat files included with MASControl2 -SpltAC1Sp-lt45_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0,1.18,-0.223,0.0468,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-lt45_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,8e-05,1.15,-0.183,0.0343,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-lt45_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.0001,1.12,-0.14,0.0225,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-lt45_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.1299744,-0.0222336,0.0015228,-3.53e-05,-4.34e-05,-0.00032724,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC1Sp-lt45_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.847,0.177,-0.0235,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-lt45_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.869,0.149,-0.0172,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-lt45_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.893,0.118,-0.0112,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-lt45_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.4985024,0.0478512,-0.0034992,-0.01084968,-5.48e-05,0.00047628,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC1Sp-lt45_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.09712,0.0536256,-0.00144828,0.0040644,0.00062208,-0.000729,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC1Sp-lt45_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC1Sp-lt45_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC2SpHiSEER_BF_fFlow,BF_fFlow,Linear,,Flow,,1.75,-1578.5656,,,,,,,,,,,,,1,1.189,From .dat files included with MASControl2 -SpltAC2SpHiSEER_BF_fT,BF_fT,BiQuadratic,,T,T,20.03024,-1.922832,0.051516,0.086184,0.0011502,-0.0076788,,,,,,,,,0,3.92,From .dat files included with MASControl2 -SpltAC2SpHiSEER_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0.00635,1.12,-0.139,0.016,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpHiSEER_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,-0.00144,1.12,-0.14,0.022,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpHiSEER_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.00726,1.11,-0.132,0.0262,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpHiSEER_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.5240096,-0.0665928,0.00299376,0.00162288,-6.51e-05,-0.00048924,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC2SpHiSEER_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.923,0.153,-0.0156,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpHiSEER_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.94,0.124,-0.0109,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpHiSEER_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.959,0.0934,-0.00688,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpHiSEER_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.54,0.0382752,-0.00297756,-0.0114912,-0.00010044,0.0005346,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpHiSEER_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,-0.172512,0.1176624,-0.00324,-0.01152,0.00077112,-0.00057024,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC2SpHiSEER_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC2SpHiSEER_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC2SpLoSEER_BF_fFlow,BF_fFlow,Linear,,Flow,,1.75,-1578.5656,,,,,,,,,,,,,1,1.189,From .dat files included with MASControl2 -SpltAC2SpLoSEER_BF_fT,BF_fT,BiQuadratic,,T,T,10.820416,-1.041264,0.0254988,0.2290608,0.00062856,-0.0117612,,,,,,,,,0,5.76,From .dat files included with MASControl2 -SpltAC2SpLoSEER_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,-0.00016,1.12,-0.143,0.0206,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpLoSEER_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,-0.00146,1.1,-0.119,0.0176,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpLoSEER_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,0.00284,1.06,-0.0687,0.00523,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpLoSEER_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.54887488,-0.0648072,0.00310068,-0.000425376,-2.55e-05,-0.00060264,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC2SpLoSEER_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.856,0.121,-0.0124,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpLoSEER_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.872,0.0941,-0.00752,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpLoSEER_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.889,0.0695,-0.00646,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpLoSEER_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.322048,-0.0286956,-0.00124092,-0.020124,-4.05e-05,0.0006804,,,,,,,,,,,From .dat files included with MASControl2 -SpltAC2SpLoSEER_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,-0.281376,0.1343088,-0.0036936,-0.0173736,0.00096552,-0.00075168,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC2SpLoSEER_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltAC2SpLoSEER_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltACEvap_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 -SpltACEvap_BF_fT,BF_fT,BiQuadratic,,T,T,16.06,-1.566,0.0405,1.75e-10,3.24e-12,3.24e-12,,,,,,,,,0,3.97,From .dat files included with MASControl2 -SpltACEvap_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0,1,0,0,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltACEvap_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,0,1,0,0,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltACEvap_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,0,1,0,0,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltACEvap_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,0.6302064,0.0171576,0.00069012,-0.00374688,0.000212544,-0.0005508,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltACEvap_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.94,0.06,0,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltACEvap_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.97,0.03,0,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltACEvap_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,1,0,0,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltACEvap_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.9516064,-0.0154008,-0.0012798,-0.00110088,0.000194724,-0.00054432,,,,,,,,,,,From .dat files included with MASControl2 -SpltACEvap_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,1.207232,-0.0528552,0.00053136,0.0261288,-0.00045684,0.0005508,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltACEvap_HIR_fT,HIR_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltACEvap_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0,0,0,0,0,0,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltHP1SpCom_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 -SpltHP1SpCom_BF_fT,BF_fT,BiQuadratic,,T,T,8.513632,-0.630072,0.0165888,-0.0450144,0.00107892,-0.0018954,,,,,,,,,0,3.33,From .dat files included with MASControl2 -SpltHP1SpCom_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,7e-05,1.23,-0.307,0.0756,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpCom_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,0.00012,1.2,-0.261,0.0596,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpCom_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-7e-05,1.17,-0.213,0.0438,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpCom_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,0.67916,0.016938,0.00069336,0.0045576,-8.42e-05,-0.00047628,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltHP1SpCom_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.805,0.233,-0.038,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpCom_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.827,0.203,-0.03,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpCom_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.852,0.17,-0.0219,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpCom_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.7311616,-0.10297296,0.00093636,0.00477864,-9.07e-05,-0.000202824,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpCom_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.7390464,-0.00778968,0.000128304,-0.00027,0.0006642,-0.000648,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltHP1SpCom_HIR_fT,HIR_fT,BiQuadratic,,T,T,0.8186976,0.01406952,0.000117936,-0.01579104,0.000222264,-0.000300024,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltHP1SpCom_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0.85516576,-0.003631392,-6.19e-06,0.02644704,0.00041148,-0.000141264,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltHP1SpRes_BF_fFlow,BF_fFlow,Linear,,Flow,,1,0,,,,,,,,,,,,,0,1,From .dat files included with MASControl2 -SpltHP1SpRes_BF_fT,BF_fT,BiQuadratic,,T,T,8.513632,-0.630072,0.0165888,-0.0450144,0.00107892,-0.0018954,,,,,,,,,0,3.33,From .dat files included with MASControl2 -SpltHP1SpRes_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,7e-05,1.23,-0.307,0.0756,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpRes_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,0.00012,1.2,-0.261,0.0596,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpRes_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-7e-05,1.17,-0.213,0.0438,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpRes_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,0.67916,0.016938,0.00069336,0.0045576,-8.42e-05,-0.00047628,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltHP1SpRes_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.805,0.233,-0.038,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpRes_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.827,0.203,-0.03,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpRes_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.852,0.17,-0.0219,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpRes_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,2.7311616,-0.10297296,0.00093636,0.00477864,-9.07e-05,-0.000202824,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP1SpRes_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,0.7390464,-0.00778968,0.000128304,-0.00027,0.0006642,-0.000648,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltHP1SpRes_HIR_fT,HIR_fT,BiQuadratic,,T,T,0.9003872,0.01108728,0.0001701,-0.02579472,0.0008424,-0.000290628,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltHP1SpRes_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0.9303344,-0.0064656,1.77e-05,0.02813472,-5.51e-06,-0.000208656,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltHP2Sp_BF_fFlow,BF_fFlow,Linear,,Flow,,1.75,-1578.5656,,,,,,,,,,,,,1,1.189,From .dat files included with MASControl2 -SpltHP2Sp_BF_fT,BF_fT,BiQuadratic,,T,T,20.03024,-1.922832,0.051516,0.086184,0.0011502,-0.0076788,,,,,,,,,0,3.92,From .dat files included with MASControl2 -SpltHP2Sp_CEIR_fPLR_Hot,CEIR_fPLR_Hot,Cubic,EIRRatio,PLR,,0.00635,1.12,-0.139,0.016,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP2Sp_CEIR_fPLR_Mod,CEIR_fPLR_Mod,Cubic,EIRRatio,PLR,,-0.00144,1.12,-0.14,0.022,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP2Sp_CEIR_fPLR_Tem,CEIR_fPLR_Tem,Cubic,EIRRatio,PLR,,-0.00726,1.11,-0.132,0.0262,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP2Sp_ClCap_fT,ClCap_fT,BiQuadratic,,T,T,1.5240096,-0.0665928,0.00299376,0.00162288,-6.51e-05,-0.00048924,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltHP2Sp_CLoss_fPLR_Hot,CLoss_fPLR_Hot,Quadratic,,PLR,,0.923,0.153,-0.0156,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP2Sp_CLoss_fPLR_Mod,CLoss_fPLR_Mod,Quadratic,,PLR,,0.94,0.124,-0.0109,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP2Sp_CLoss_fPLR_Tem,CLoss_fPLR_Tem,Quadratic,,PLR,,0.959,0.0934,-0.00688,,,,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP2Sp_ClSH_fT,ClSH_fT,BiQuadratic,,T,T,1.54,0.0382752,-0.00297756,-0.0114912,-0.00010044,0.0005346,,,,,,,,,,,From .dat files included with MASControl2 -SpltHP2Sp_EIR_fT,EIR_fT,BiQuadratic,EIRRatio,T,T,-0.172512,0.1176624,-0.00324,-0.01152,0.00077112,-0.00057024,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltHP2Sp_HIR_fT,HIR_fT,BiQuadratic,,T,T,0.9272864,0.00802008,0.000201528,-0.02177136,0.000729,-0.000303264,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SpltHP2Sp_HtCap_fT,HtCap_fT,BiQuadratic,,T,T,0.8756304,-0.00466344,1.62e-14,0.02912976,0.00012636,-0.000163296,,,,,7.22222,29.44444,-23.333,46.11111,,,From .dat files included with MASControl2 -SteamTurbine-Flow-fPSIG,SteamTurbineGen,BiQuadratic,QRatio,PSIG,PSIG,38.79236,-3.07e-05,1.11e-11,0.000147951,1.93e-11,-7.36e-11,,,,,,,,,18,100,From .dat files included with MASControl2 -SteamTurbine-HIR-fPLR,SteamTurbineGen,Quadratic,,PLR,,0.12838545,0.90049523,-0.02888074,,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Stippled_Optical-fAOI,PV-Module,Cubic,,AOI,,4.70208168,-0.21138079,0.00393233,-2.4e-05,,,,,,,,,,,,,From .dat files included with MASControl2 -SWH-EFFFPLR-NECB2011,Water Heater,Cubic,FIRRatio,QRatio,,0.7576,1.0071,-1.4443,0.6844,,,,,,,0,1,,,,,From NECB 2011 -Tower_Fan_Curve,,Cubic,,,,0,0,0,1,,,,,,,0,1,,,,,From Prototype Buildings -Transformer-Loss-fPLR,ElecMeters,Linear,QRatio,PLR,,0.1,0.9,,,,,,,,,,,,,,,From .dat files included with MASControl2 -Two-Speed Fan EIR fPLR,FanEIR-FPLR,Linear,,PLR,,-0.764706,1.764706,,,,,,,,,,,,,0.4,,From .dat files included with MASControl2 -TwoSpeedFan,FanEIR-FPLR,Cubic,EIRRatio,PLR,,0.000281,-0.0579,0.586,0.471,,,,,,,,,,,,,From .dat files included with MASControl2 -Typical VSD Fan,FanEIR-FPLR,Cubic,PwrRatio,FlowRatio,,0.047182815,0.130541742,-0.117286942,0.940313747,,,,,,,0,1,,,0.1,,"From California Energy Commision, ""Advanced Variable Air Volume System Design Guide,"" October 2003" -TypicalCyclingAC-EIR-fPLR,CyclingAC,Cubic,EIRRatio,PLR,,6.26e-05,1.17517,-0.201513,0.0263344,,,,,,,,,,,,,From .dat files included with MASControl2 -Vane Axial w Var Pitch FPLR,FanEIR-FPLR,Quadratic,,PLR,,0.212048,-0.569286,1.345238,,,,,,,,,,,,0.15,1,From .dat files included with MASControl2 -Variable Speed Drive FPLR,FanEIR-FPLR,Quadratic,,PLR,,0.219762,-0.874784,1.652597,,,,,,,,,,,,0.1,1,From .dat files included with MASControl2 -VarVolFan-AFBIFanCurve-NECB2011-FPLR,Fan,Cubic,PwrRatio,FlowRatio,,-2.4176,9.5874,-11.559,5.4009,,,,,,,0.68,1,,,,,From NECB 2011 -VarVolFan-AFBIInletVanes-NECB2011-FPLR,Fan,Cubic,PwrRatio,FlowRatio,,-4.1457,16.803,-19.471,7.8488,,,,,,,0.5,1,,,,,From NECB 2011 -VarVolFan-FCInletVanes-NECB2011-FPLR,Fan,Cubic,PwrRatio,FlowRatio,,-0.3477,4.0976,-5.0024,2.268,,,,,,,0.22,1,,,,,From NECB 2011 -VarVolFan-VSD-NECB2011-FPLR,Fan,Cubic,PwrRatio,FlowRatio,,0.1389,1.7699,-1.615,0.6996,,,,,,,0.04,1,,,,,From NECB 2011 -VFD-Loss-fPLR,Pumps,Linear,QRatio,PLR,,0.6,0.4,,,,,,,,,,,,,,,From .dat files included with MASControl2 -VRF-HP-Resys-ClCap-fSST&ODB,CondUnit,BiQuadratic,QRatio,SST,ODB,1.26588416,0,0,-0.007582032,-2.14e-06,0,,,,,,,,,,,From .dat files included with MASControl2 -VRF-HP-Resys-ClEIR-fSST&ODB,CondUnit,BiQuadratic,EIRRatio,SST,ODB,0.384832,0,0,0.0092304,0.000238,0,,,,,,,,,,,From .dat files included with MASControl2 -VRF-HP-Resys-Crankcase-fPLR,CondUnit,Quadratic,,PLR,,1,-1.72,0.72,,,,,,,,,,,,,,From .dat files included with MASControl2 -VRF-HP-Resys-Cycle-fPLR,CondUnit,Linear,QRatio,PLR,,0.898,0.102,,,,,,,,,,,,,,,From .dat files included with MASControl2 -VRF-HP-Resys-HtCap-fSCT&OWB,CondUnit,BiQuadratic,QRatio,SCT,OWB,0.89783456,0,0,0.016707888,6.16e-07,0,,,,,,,,,,,From .dat files included with MASControl2 -VRF-HP-Resys-HtEIR-fSCT&OWB,CondUnit,BiQuadratic,EIRRatio,SCT,OWB,1.0525344,0,0,-0.00815688,-8.72e-05,0,,,,,,,,,,,From .dat files included with MASControl2 -VSD-TWR-FAN-FPLR,Cooling Tower,Cubic,,,,0.33162901,-0.88567609,0.60556507,0.9484823,,,,,,,0,1,,,,,From PNNL PRM Reference Manual -Water-Cooled-Bypass-fAirflow,"DXCooling,WCC",Cubic,QRatio,Airflow,,0.9,-3.73,7.37,-3.54,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Water-Cooled-Bypass-fEWB&EWT,"DXCooling,WCC",BiQuadratic,QRatio,EWB,EWT,-5.51104768,0.73563552,-0.0185004,0.142520616,0.000942,-0.010213452,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -Water-Cooled-Cool-Cap-fEWB&EWT,"DXCooling,WCC",BiQuadratic,QRatio,EWB,EWT,0.8254384,0.00574416,0.000735,-0.00310374,-1.46e-05,-0.000194,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -Water-Cooled-EIR-fEWB&EWT,"DXCooling,WCC",BiQuadratic,EIRRatio,EWB,EWT,0.0985984,0.062604,-0.00184356,0.01183032,0.000292,-0.000395,,,,,12.77778,29.44444,12.77778,46.11111,,,From .dat files included with MASControl2 -Water-Cooled-EIR-fPLR,"DXCooling,WCC",Cubic,EIRRatio,PLR,,0.201,-0.0312,1.9504979,-1.1205104,,,,,,,0,1.05,,,,,From .dat files included with MASControl2 -Water-Cooled-Sens-Cap-fEWB&EWT,"DXCooling,WCC",BiQuadratic,QRatio,EWB,EWT,2.1542784,-0.0242784,-0.00148716,-0.00829548,-2.96e-05,0.000272,,,,,12.77778,29.44444,10,46.11111,,,From .dat files included with MASControl2 -WaterCooled_Centrifugal_CAPFT_NECB2011,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.707908,-0.00200657,-0.00259605,0.0300588,-0.00105643,0.0020457,,,,,5,10,24,35,,,From NECB 2011 -WaterCooled_Centrifugal_Chiller_150TO300_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_150TO300_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_150TO300_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_2010_PathA_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.7600172,0.0147432,0.0002144,0.0207218,-0.0006425,0.0008007,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_2010_PathA_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.6772577,0.0117857,-0.0001967,0.0014414,0.0003005,-0.0006807,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_2010_PathB_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.536234,0.005581,-0.0013654,0.0488966,-0.0012018,0.0010523,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_2010_PathB_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,1.0821822,0.0042977,-0.0013182,-0.0260781,0.0008256,-0.0006013,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_300TO600_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_300TO600_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_AllCapacities_2004_2007_2010_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010. EIRFPLR curve is identical for all WaterCooled Chillers" -WaterCooled_Centrifugal_Chiller_GT150_2004_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.7600172,0.0147432,0.0002144,0.0207218,-0.0006425,0.0008007,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_GT150_2004_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.6772577,0.0117857,-0.0001967,0.0014414,0.0003005,-0.0006807,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_GT300_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_GT600_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_GT600_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_LT150_2004_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.7446451,0.0114858,1.48e-05,0.022401,-0.000688,0.0009839,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_LT150_2004_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.772877,0.022101,-7.99e-05,-0.0070045,0.0004763,-0.0010612,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_LT150_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_Chiller_LT150_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Centrifugal_EIRFPLR_NECB2011,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.171493,0.588202,0.237373,,,,,,,,0,1,,,,,From NECB 2011 -WaterCooled_Centrifugal_EIRFT_NECB2011,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.560523,-0.0137816,6.56424e-05,0.0132194,0.000268596,-0.000501131,,,,,5,10,24,35,,,From NECB 2011 -WaterCooled_PositiveDisplacement_Chiller_150TO300_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_150TO300_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_150TO300_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_2004_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.906115,0.029227,-0.0003647,-0.0009709,-9.05e-05,0.0002527,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_2004_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.3617105,-0.0229833,0.0009519,0.0131889,0.0003752,-0.0007059,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_2010_PathB_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.9061171,0.0292267,-0.0003665,-0.0009698,-9.07e-05,0.0002535,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_2010_PathB_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.3617782,-0.0230016,0.0009672,0.0131801,0.0003761,-0.0007121,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_75TO150_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_75TO150_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_75TO150_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.906115,0.0292277,-0.0003647,-0.0009709,-9.05e-05,0.0002527,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_GT150_2010_PathA_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.3773115,-0.0229032,0.0016504,0.0118156,0.0004345,-0.0010132,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_GT300_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_GT300_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_GT300_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_CAPFT,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.906115,0.0292277,-0.0003647,-0.0009709,-9.05e-05,0.0002527,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_LT150_2010_PathA_EIRFT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.3617105,-0.0229833,0.0009519,0.0131889,0.0003752,-0.0007059,,,,,5,10,17.78,46.11,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_LT75_2004_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_LT75_2010_PathA_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_PositiveDisplacement_Chiller_LT75_2010_PathB_EIRFPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.1360532,0.008642703,3.85558e-06,1.024034,0.06047444,-0.00894786,0,0.05706602,0,0,31.13,36.52,0.19,1.03,,,"Based on Dick Lord's study dated January 17, 2010." -WaterCooled_Reciprocating_CAPFT_NECB2011,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,1.03031,0.0334698,0.00023639,-0.00729587,-2.3166e-05,-0.000148943,,,,,5,10,24,35,,,From NECB 2011 -WaterCooled_Reciprocating_EIRFPLR_NECB2011,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.081441,0.419271,0.499396,,,,,,,,0,1,,,,,From NECB 2011 -WaterCooled_Reciprocating_EIRFT_NECB2011,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.499699,-0.0130841,0.000266425,0.0165925,0.000185393,-0.000375646,,,,,5,10,24,35,,,From NECB 2011 -WaterCooled_Screw_CAPFT_NECB2011,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.812998,-0.0142532,-0.00161799,0.0263844,-0.00091543,0.00169601,,,,,5,10,24,35,,,From NECB 2011 -WaterCooled_Screw_EIRFPLR_NECB2011,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.330188,0.235543,0.460708,,,,,,,,0,1,,,,,From NECB 2011 -WaterCooled_Screw_EIRFT_NECB2011,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.638103,0.00630158,0.00092327,-0.00455294,0.000825682,-0.00156152,,,,,5,10,24,35,,,From NECB 2011 -WaterCooled_Scroll_CAPFT_NECB2011,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.94418,0.0337102,9.75564e-05,-0.00322114,-4.91832e-05,-0.000177584,,,,,5,10,24,35,,,From NECB 2011 -WaterCooled_Scroll_EIRFPLR_NECB2011,Electric Chiller,Quadratic,EIRRatio,QRatio,,0.04412,0.640367,0.319555,,,,,,,,0,1,,,,,From NECB 2011 -WaterCooled_Scroll_EIRFT_NECB2011,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.727393,-0.0118922,0.000541177,0.00187934,0.000473461,-0.000711472,,,,,5,10,24,35,,,From NECB 2011 -WC Screw Default 90.1-2004 Cap_fTWC,Electric Chiller,BiQuadratic,QRatio,Tchws,Toadb,0.906115,0.0292277,-0.0003647,-0.0009709,-9.05e-05,0.0002527,,,,,0,20,0,50,,,From RefBldgLargeOfficePost1980 & Pre1980 -WC Screw Default 90.1-2004 EIR_fT,Electric Chiller,BiQuadratic,EIRRatio,Tchws,Toadb,0.3617105,-0.0229833,-0.0009519,0.0131889,0.0003752,-0.0007059,,,,,0,20,0,50,,,From RefBldgLargeOfficePost1980 % Pre1980 -WC Screw GTE 300tons Default 90.1-2004 EIR_fPLR,Electric Chiller,BiCubic,EIRRatio,Tcws,QRatio,-0.2737954,0.02822257,-8.09766e-05,0.9612284,0.3029741,-0.02421933,0,-0.03885224,0,0,18.54,31.63,0.2,1.02,,,From RefBldgLargeOfficePost1980 & Pre1980 -WC_PD_2004_CAPFT,,BiQuadratic,,,,0.906115,0.0292277,-0.0003647,-0.0009709,-9.05e-05,0.0002527,,,,,5,10,17.78,46.11,,,From PNNL Prototype Hospital -WC_PD_2010_PB_CAPFT,,BiQuadratic,,,,0.9061171,0.0292267,-0.0003665,-0.0009698,-9.07e-05,0.0002535,,,,,5,10,17.78,46.11,,,From PNNL Prototype OfficeLarge -WC_PD_2010_PB_EIRFT,,BiQuadratic,,,,0.3617782,-0.0230016,0.0009672,0.0131801,0.0003761,-0.0007121,,,,,5,10,17.78,46.11,,,From PNNL Prototype OfficeLarge -MT_compressor_power,Refrigeration,BiCubic,Power,Suction T,Discharge T,7438.92229,-269.59756,-9.8561045,553.57326,-3.3858896,14.8657878,-0.1007963,0.00982279,0.09736236,-0.039675217,-23.3,7.2,10,60,,,From AEDG -MT_compressor_capacity,Refrigeration,BiCubic,Capacity,Suction T,Discharge T,151166.436,5266.34789,60.6727151,-1851.5594,5.73132755,-46.927717,0.1364012,-0.0356979,-0.403054,-0.039290478,-23.3,-7.2,10,60,,,From AEDG -MT_compressor_capacity_smallandold,Refrigeration,BiCubic,Capacity,Suction T,Discharge T,15000,541.8,7.285,-118,-0.3645,-3.05,0.0344,0.00225,-0.03927,-0.007307,-17.8,4.4,10,48.9,,,From EP DataSets -MT_compressor_power_smallandold,Refrigeration,BiCubic,Power,Suction T,Discharge T,483.6,-53.2,-1.384,56.19,0.003688,1.439,-0.008268,-0.00281,0.007222,0.006025,-17.8,4.4,10,48.9,,,From EP DataSets -LT_compressor_capacity_smallandold,Refrigeration,BiCubic,Capacity,Suction T,Discharge T,23500,816.7,10.7,-28.24,0.1131,-0.4553,0.05604,-0.00412,-0.006728,0.006782,-40,-17.8,10,48.9,,,From EP DataSets -LT_compressor_power_smallandold,Refrigeration,BiCubic,Power,Suction T,Discharge T,4018,95,1.507,5.705,1.247,-1.381,0.01277,-0.007518,-0.02424,0.02917,-40,-17.8,10,48.9,,,From EP DataSets -Glass Door Latent Curve Case,Refrigeration,Cubic,,,,0.3379,0.0309,0.0005,4e-05,,,,,,,-55,55,,,,,From AEDG -Coffin Latent Curve Case,Refrigeration,Cubic,,,,0.3379,0.0309,0.0005,4e-05,,,,,,,-55,55,,,,,From AEDG -Open Latent Curve Case,Refrigeration,Cubic,,,,-0.0187,0.0458,0.0011,5e-05,,,,,,,-55,55,,,,,From AEDG -Glass Door Defrost Curve Walkin,Refrigeration,Cubic,,,,0.3475,0.0296,0.0007,3e-05,,,,,,,-55,55,,,,,From AEDG -Coffin Defrost Curve Walkin,Refrigeration,Cubic,,,,0.3475,0.0296,0.0007,3e-05,,,,,,,-55,55,,,,,From AEDG -Open Defrost Curve Walkin,Refrigeration,Cubic,,,,0.0572,0.0461,0.0004,6e-05,,,,,,,-55,55,,,,,From AEDG -Refrigeration Case Latent Credit Curve,Refrigeration,Cubic,,,,0.026526281,0.001078032,6.02558e-05,1.23732e-06,,,,,,,-35,20,,,,, diff --git a/data/openstudio_standards_data/database_files/support_schedules.csv b/data/openstudio_standards_data/database_files/support_schedules.csv deleted file mode 100644 index 20ad38159e..0000000000 --- a/data/openstudio_standards_data/database_files/support_schedules.csv +++ /dev/null @@ -1,811 +0,0 @@ -name,category,units,day_types,start_date,end_date,type,hr_1,hr_2,hr_3,hr_4,hr_5,hr_6,hr_7,hr_8,hr_9,hr_10,hr_11,hr_12,hr_13,hr_14,hr_15,hr_16,hr_17,hr_18,hr_19,hr_20,hr_21,hr_22,hr_23,hr_24,annotation -corridor_all_other,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.9,0.5,0,0,0, -corridor_all_other,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.9,0.51,0,0,0, -corridor_all_other,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.9,0.51,0,0,0, -corridor_all_other,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -corridor_all_other,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -corridor_all_other,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -corridor_all_other,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -corridor_all_other,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -corridor_all_other,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -dining_all_other,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0.25,0.9,0.9,0.75,0,0,0,0,0,0,0,0,0, -dining_all_other,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.25,0.25,0.25,0.9,0.9,0.5,0.25,0.25,0,0,0,0,0,0,0, -dining_all_other,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.25,0.25,0.25,0.9,0.9,0.5,0.25,0.25,0,0,0,0,0,0,0, -dining_all_other,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0,0,0, -dining_all_other,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, -dining_all_other,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, -dining_all_other,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.08,0.06,0.06,0.06,0.06,0.06,0.06, -dining_all_other,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.08,0.06,0.06,0.06,0.06,0.06,0.06, -dining_all_other,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.08,0.06,0.06,0.06,0.06,0.06,0.06, -electrical_mechanical,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0,0,0,0,0,0,0, -electrical_mechanical,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -electrical_mechanical,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -electrical_mechanical,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0,0,0,0,0,0,0, -electrical_mechanical,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -electrical_mechanical,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -electrical_mechanical,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.24,0.24,0.24,0.24,0.24,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25, -electrical_mechanical,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.24,0.24,0.24,0.24,0.24,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25, -electrical_mechanical,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.24,0.24,0.24,0.24,0.24,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25, -kitchen,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.5,0.25,0.25,0.9,0.9,0.75,0.25,0,0,0,0,0,0,0,0, -kitchen,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.25,0.25,0.25,0.9,0.75,0.5,0.25,0.25,0,0,0,0,0,0,0, -kitchen,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.25,0.25,0.25,0.9,0.75,0.5,0.25,0.25,0,0,0,0,0,0,0, -kitchen,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0,0, -kitchen,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, -kitchen,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, -kitchen,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.07,0.05,0.05,0.05,0.05,0.05,0.05, -kitchen,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.27,0.06,0.05,0.05,0.05,0.05,0.05, -kitchen,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.27,0.06,0.05,0.05,0.05,0.05,0.05, -laboratory,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -laboratory,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.05,0.125,0.375,0.45,0.45,0.25,0.25,0.45,0.45,0.25,0.25,0,0,0,0,0,0, -laboratory,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.05,0.125,0.625,0.9,0.9,0.75,0.75,0.9,0.825,0.25,0.25,0,0,0,0,0,0, -laboratory,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -laboratory,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0,0,0,0, -laboratory,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0,0,0,0,0,0, -laboratory,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, -laboratory,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.055,0.48,0.48,0.48,0.48,0.48,0.48,0.48,0.48,0.48,0.48,0.055,0.055,0.05,0.05,0.05,0.05, -laboratory,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.055,0.48,0.715,0.9,0.9,0.9,0.83,0.9,0.83,0.48,0.48,0.055,0.055,0.05,0.05,0.05,0.05, -lobby_all_other,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.25,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -lobby_all_other,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0,0,0,0,0,0, -lobby_all_other,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0,0,0,0,0,0, -lobby_all_other,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -lobby_all_other,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0,0,0,0,0,0, -lobby_all_other,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0,0,0,0,0,0, -lobby_all_other,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.53,0.9,0.9,0.05,0.05,0.05,0.05, -lobby_all_other,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.48,0.48,0.48,0.48,0.48,0.48,0.48,0.715,0.52,0.05,0.05,0.05,0.05,0.05,0.05, -lobby_all_other,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.48,0.48,0.48,0.48,0.48,0.48,0.48,0.715,0.52,0.05,0.05,0.05,0.05,0.05,0.05, -locker_room,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.5,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.75,0.25,0,0,0,0,0, -locker_room,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -locker_room,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -locker_room,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -locker_room,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -locker_room,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -locker_room,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -locker_room,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.06,0.05,0.05,0.05, -locker_room,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.06,0.05,0.05,0.05, -lounge_breakroom_all_other,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.25,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -lounge_breakroom_all_other,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, -lounge_breakroom_all_other,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, -lounge_breakroom_all_other,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -lounge_breakroom_all_other,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -lounge_breakroom_all_other,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -lounge_breakroom_all_other,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -lounge_breakroom_all_other,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.53,0.9,0.9,0.9,0.05,0.05,0.05, -lounge_breakroom_all_other,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.53,0.9,0.9,0.9,0.05,0.05,0.05, -office_enclosed_lte_250_sf,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.375,0.825,0.9,0.9,0.625,0.625,0.9,0.9,0.7,0.5,0,0,0,0,0,0, -office_enclosed_lte_250_sf,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -office_enclosed_lte_250_sf,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -office_enclosed_lte_250_sf,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -office_enclosed_lte_250_sf,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -office_enclosed_lte_250_sf,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -office_enclosed_lte_250_sf,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.7,0.05,0.05,0.05,0.05, -office_enclosed_lte_250_sf,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.4,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.4,0.15,0.05,0.05,0.05,0.05, -office_enclosed_lte_250_sf,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.4,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.4,0.15,0.05,0.05,0.05,0.05, -office_enclosed_gt_250_sf,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -office_enclosed_gt_250_sf,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -office_enclosed_gt_250_sf,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -office_enclosed_gt_250_sf,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -office_enclosed_gt_250_sf,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -office_enclosed_gt_250_sf,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -office_enclosed_gt_250_sf,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, -office_enclosed_gt_250_sf,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -office_enclosed_gt_250_sf,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -office_open,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.375,0.825,0.9,0.9,0.625,0.625,0.9,0.9,0.7,0.5,0,0,0,0,0,0, -office_open,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -office_open,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -office_open,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -office_open,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -office_open,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -office_open,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.825,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.825,0.7,0.05,0.05,0.05,0.05, -office_open,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -office_open,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -restroom_all_other,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.375,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.5,0.5,0,0,0, -restroom_all_other,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.375,0.5,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0.25,0,0,0, -restroom_all_other,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.375,0.5,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0.25,0,0,0, -restroom_all_other,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -restroom_all_other,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -restroom_all_other,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -restroom_all_other,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -restroom_all_other,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -restroom_all_other,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -stairwell,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.7,0.9,0.5,0,0,0, -stairwell,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.38,0,0,0, -stairwell,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.38,0,0,0, -stairwell,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -stairwell,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -stairwell,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -stairwell,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -stairwell,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -stairwell,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -storage_50_to_1000_sf_all_other,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.3,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -storage_50_to_1000_sf_all_other,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.1,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0,0,0,0,0,0, -storage_50_to_1000_sf_all_other,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.1,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0,0,0,0,0,0, -storage_50_to_1000_sf_all_other,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -storage_50_to_1000_sf_all_other,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -storage_50_to_1000_sf_all_other,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -storage_50_to_1000_sf_all_other,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -storage_50_to_1000_sf_all_other,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -storage_50_to_1000_sf_all_other,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -storage_lt_50_sf_all_other,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.05,0.3,0.825,0.9,0.9,0.825,0.825,0.9,0.9,0.9,0.75,0.05,0.05,0,0,0,0, -storage_lt_50_sf_all_other,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.175,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0,0,0,0,0,0, -storage_lt_50_sf_all_other,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.175,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0,0,0,0,0,0, -storage_lt_50_sf_all_other,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0,0,0,0, -storage_lt_50_sf_all_other,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -storage_lt_50_sf_all_other,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -storage_lt_50_sf_all_other,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -storage_lt_50_sf_all_other,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -storage_lt_50_sf_all_other,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -vehicular_maintenance,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.45,0.45,0.5,0.575,0.825,0.9,0.9,0.7,0.7,0.9,0.9,0.7,0.7,0.45,0.45,0.45,0,0,0, -vehicular_maintenance,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, -vehicular_maintenance,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, -vehicular_maintenance,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0.45,0,0,0, -vehicular_maintenance,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, -vehicular_maintenance,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, -vehicular_maintenance,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.045,0.045,0.045,0.045,0.045,0.47,0.47,0.47,0.47,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.47,0.47,0.47,0.47,0.045,0.045,0.045, -vehicular_maintenance,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.045,0.045,0.045,0.045,0.045,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.045,0.045,0.045, -vehicular_maintenance,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.045,0.045,0.045,0.045,0.045,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.47,0.045,0.045,0.045, -workshop,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -workshop,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, -workshop,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, -workshop,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -workshop,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -workshop,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -workshop,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.07,0.07,0.05,0.05,0.05,0.05, -workshop,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -workshop,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -atrium_first_three_floors,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0.25,0.25,0.25,0.25,0.25,0, -atrium_first_three_floors,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0.25,0.25,0.25,0.25,0.25,0, -atrium_first_three_floors,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0.25,0.25,0.25,0.25,0.25,0, -atrium_first_three_floors,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -atrium_first_three_floors,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -atrium_first_three_floors,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -atrium_first_three_floors,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -atrium_first_three_floors,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -atrium_first_three_floors,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_convention_center,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_convention_center,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_convention_center,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_convention_center,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_convention_center,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_convention_center,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_convention_center,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_convention_center,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_convention_center,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -classroom_lecture_training_all_other,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -classroom_lecture_training_all_other,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, -classroom_lecture_training_all_other,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, -classroom_lecture_training_all_other,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -classroom_lecture_training_all_other,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -classroom_lecture_training_all_other,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -classroom_lecture_training_all_other,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.07,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.05,0.05,0.05,0.05, -classroom_lecture_training_all_other,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, -classroom_lecture_training_all_other,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, -conference_meeting_multipurpose,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -conference_meeting_multipurpose,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, -conference_meeting_multipurpose,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, -conference_meeting_multipurpose,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -conference_meeting_multipurpose,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -conference_meeting_multipurpose,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -conference_meeting_multipurpose,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -conference_meeting_multipurpose,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, -conference_meeting_multipurpose,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.9,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, -exhibit_convention_center,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -exhibit_convention_center,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -exhibit_convention_center,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -exhibit_convention_center,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -exhibit_convention_center,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -exhibit_convention_center,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -exhibit_convention_center,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -exhibit_convention_center,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -exhibit_convention_center,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -gymnasium_exercise_area,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -gymnasium_exercise_area,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -gymnasium_exercise_area,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -gymnasium_exercise_area,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -gymnasium_exercise_area,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -gymnasium_exercise_area,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -gymnasium_exercise_area,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -gymnasium_exercise_area,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -gymnasium_exercise_area,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -gymnasium_playing_area,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0.25,0,0,0,0,0, -gymnasium_playing_area,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -gymnasium_playing_area,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -gymnasium_playing_area,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -gymnasium_playing_area,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -gymnasium_playing_area,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -gymnasium_playing_area,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.475,0.475,0.475,0.05,0.05,0.05, -gymnasium_playing_area,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.83,0.9,0.9,0.83,0.83,0.9,0.9,0.9,0.83,0.475,0.475,0.475,0.05,0.05,0.05, -gymnasium_playing_area,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.83,0.9,0.9,0.83,0.83,0.9,0.9,0.9,0.83,0.475,0.475,0.475,0.05,0.05,0.05, -laundry_washing,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0,0,0,0,0,0, -laundry_washing,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, -laundry_washing,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, -laundry_washing,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -laundry_washing,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, -laundry_washing,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, -laundry_washing,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.06,0.06,0.06,0.05,0.05,0.05,0.05, -laundry_washing,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.06,0.06,0.06,0.05,0.05,0.05,0.05, -laundry_washing,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.06,0.06,0.06,0.05,0.05,0.05,0.05, -lobby_elevator,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -lobby_elevator,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, -lobby_elevator,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, -lobby_elevator,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -lobby_elevator,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -lobby_elevator,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -lobby_elevator,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, -lobby_elevator,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -lobby_elevator,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -nurses_station,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -nurses_station,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -nurses_station,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -nurses_station,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -nurses_station,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -nurses_station,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -nurses_station,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, -nurses_station,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, -nurses_station,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, -post_office_sorting_area,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -post_office_sorting_area,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -post_office_sorting_area,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -post_office_sorting_area,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -post_office_sorting_area,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -post_office_sorting_area,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -post_office_sorting_area,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -post_office_sorting_area,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -post_office_sorting_area,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -sales,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -sales,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -sales,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -sales,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -sales,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -sales,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -sales,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -sales,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -sales,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -sports_arena_playing_area_class_iv,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -sports_arena_playing_area_class_iv,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -sports_arena_playing_area_class_iv,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -sports_arena_playing_area_class_iv,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -sports_arena_playing_area_class_iv,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -sports_arena_playing_area_class_iv,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -sports_arena_playing_area_class_iv,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -sports_arena_playing_area_class_iv,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -sports_arena_playing_area_class_iv,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -audience_seating_all_other,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.125,0.25,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.625,0.25,0,0,0,0,0, -audience_seating_all_other,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.625,0.9,0.9,0.825,0.75,0.9,0.825,0.45,0.375,0,0,0,0,0,0, -audience_seating_all_other,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.625,0.9,0.9,0.825,0.75,0.9,0.825,0.45,0.375,0,0,0,0,0,0, -audience_seating_all_other,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -audience_seating_all_other,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0,0,0,0,0,0, -audience_seating_all_other,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0,0,0,0,0,0, -audience_seating_all_other,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.475,0.05,0.05,0.05, -audience_seating_all_other,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.645,0.9,0.9,0.83,0.76,0.9,0.83,0.475,0.405,0.05,0.05,0.05,0.05,0.05,0.05, -audience_seating_all_other,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.83,0.9,0.9,0.83,0.83,0.9,0.9,0.9,0.405,0.05,0.05,0.05,0.05,0.05,0.05, -confinement_cells,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0.125,0.125,0.125,0.125,0.125,0.125,0.125,0.125,0.125,0,0,0,0,0.25,0.75, -confinement_cells,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, -confinement_cells,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, -confinement_cells,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0,0,0.9,0.45, -confinement_cells,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.45, -confinement_cells,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.45, -confinement_cells,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -confinement_cells,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -confinement_cells,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -courtroom,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -courtroom,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, -courtroom,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, -courtroom,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -courtroom,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -courtroom,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -courtroom,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.07,0.07,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.07,0.07,0.07,0.07,0.05,0.05,0.05, -courtroom,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.07,0.07,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.07,0.07,0.07,0.07,0.05,0.05,0.05, -courtroom,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.07,0.07,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.07,0.07,0.07,0.07,0.05,0.05,0.05, -judges_chambers,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -judges_chambers,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -judges_chambers,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -judges_chambers,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -judges_chambers,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -judges_chambers,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -judges_chambers,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -judges_chambers,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -judges_chambers,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -library_stacks,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -library_stacks,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0,0,0,0,0,0, -library_stacks,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0,0,0,0,0,0, -library_stacks,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -library_stacks,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.5,0.9,0.9,0.9,0.75,0.9,0.75,0,0,0,0,0,0,0,0, -library_stacks,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.5,0.9,0.9,0.9,0.75,0.9,0.75,0,0,0,0,0,0,0,0, -library_stacks,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -library_stacks,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -library_stacks,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -storage_inactive,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.3,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.3,0,0,0,0,0,0, -storage_inactive,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0,0,0,0,0,0,0, -storage_inactive,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0.3,0,0,0,0,0,0,0, -storage_inactive,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -storage_inactive,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, -storage_inactive,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, -storage_inactive,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -storage_inactive,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -storage_inactive,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -dining_bar_lounge_leisure,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, -dining_bar_lounge_leisure,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, -dining_bar_lounge_leisure,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, -dining_bar_lounge_leisure,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -dining_bar_lounge_leisure,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -dining_bar_lounge_leisure,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -dining_bar_lounge_leisure,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -dining_bar_lounge_leisure,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -dining_bar_lounge_leisure,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -dining_cafeteria_fast_food,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, -dining_cafeteria_fast_food,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, -dining_cafeteria_fast_food,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, -dining_cafeteria_fast_food,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -dining_cafeteria_fast_food,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -dining_cafeteria_fast_food,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -dining_cafeteria_fast_food,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -dining_cafeteria_fast_food,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -dining_cafeteria_fast_food,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -dining_family,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, -dining_family,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, -dining_family,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.25,0.5,0.5,0.5,0.9,0.9,0.5,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.5,0, -dining_family,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -dining_family,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -dining_family,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -dining_family,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -dining_family,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -dining_family,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -computer_room,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0.75,0.75,0.75,0.5,0.5,0, -computer_room,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0.75,0.75,0.75,0.5,0.5,0, -computer_room,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0.75,0.75,0.75,0.5,0.5,0, -computer_room,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -computer_room,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -computer_room,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -computer_room,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05, -computer_room,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05, -computer_room,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05, -dormitory_living_quarters,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75,0.9, -dormitory_living_quarters,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75,0.9, -dormitory_living_quarters,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75,0.9, -dormitory_living_quarters,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.5,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.25, -dormitory_living_quarters,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.5,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.25, -dormitory_living_quarters,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.5,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.25, -dormitory_living_quarters,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -dormitory_living_quarters,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -dormitory_living_quarters,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -audience_seating_exercise_center,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_exercise_center,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_exercise_center,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_exercise_center,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_exercise_center,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_exercise_center,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_exercise_center,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_exercise_center,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_exercise_center,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -exam_treatment,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -exam_treatment,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -exam_treatment,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -exam_treatment,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -exam_treatment,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -exam_treatment,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -exam_treatment,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, -exam_treatment,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -exam_treatment,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -library_reading,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0,0,0,0,0,0, -library_reading,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0,0,0,0,0,0,0, -library_reading,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0,0,0,0,0,0,0, -library_reading,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -library_reading,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, -library_reading,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0,0, -library_reading,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -library_reading,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -library_reading,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -emergency_vehicle_garage,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0,0,0,0,0,0,0, -emergency_vehicle_garage,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -emergency_vehicle_garage,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -emergency_vehicle_garage,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0.01,0,0,0,0,0,0,0, -emergency_vehicle_garage,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -emergency_vehicle_garage,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -emergency_vehicle_garage,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -emergency_vehicle_garage,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -emergency_vehicle_garage,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -firestation_sleeping_quarters,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, -firestation_sleeping_quarters,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, -firestation_sleeping_quarters,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, -firestation_sleeping_quarters,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0, -firestation_sleeping_quarters,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0, -firestation_sleeping_quarters,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0, -firestation_sleeping_quarters,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -firestation_sleeping_quarters,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -firestation_sleeping_quarters,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -parking_area_interior,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0.125,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.705,0.9,0.575,0.125,0,0,0, -parking_area_interior,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.58,0.46,0.58,0.75,0.75,0.705,0.46,0.46,0.5,0.25,0,0,0,0,0, -parking_area_interior,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.58,0.46,0.58,0.75,0.75,0.705,0.46,0.46,0.5,0.25,0,0,0,0,0, -parking_area_interior,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0,0,0, -parking_area_interior,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -parking_area_interior,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -parking_area_interior,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -parking_area_interior,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -parking_area_interior,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -audience_seating_gymnasium,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_gymnasium,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_gymnasium,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_gymnasium,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_gymnasium,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_gymnasium,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_gymnasium,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_gymnasium,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_gymnasium,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -emergency_room,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.575,0.7,0.9,0.9,0.9,0.825,0.825,0.9,0.9,0.9,0.7,0.575,0.45,0.45,0,0,0, -emergency_room,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, -emergency_room,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, -emergency_room,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0,0,0, -emergency_room,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, -emergency_room,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, -emergency_room,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.475,0.475,0.475,0.05,0.05,0.05, -emergency_room,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.05,0.05,0.05, -emergency_room,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.05,0.05,0.05, -patient_room,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.575,0.7,0.9,0.9,0.9,0.825,0.825,0.9,0.9,0.9,0.7,0.575,0.45,0.45,0.45,0.45,0.45, -patient_room,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45, -patient_room,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45, -patient_room,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.15,0.8,0.9,0.9,0.9,0.9,0.9,0.9,0.8,0.6,0.6,0.8,0.9,0.45,0.45,0.45,0.35,0.15, -patient_room,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.15,0.35,0.45,0.45,0.45,0.45,0.45,0.45,0.35,0.15,0.15,0.35,0.45,0.45,0.45,0.45,0.35,0.15, -patient_room,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.15,0.35,0.45,0.45,0.45,0.45,0.45,0.45,0.35,0.15,0.15,0.35,0.45,0.45,0.45,0.45,0.35,0.15, -patient_room,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.475,0.475,0.475,0.475,0.475,0.195, -patient_room,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.195, -patient_room,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.195, -pharmacy,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -pharmacy,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -pharmacy,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -pharmacy,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -pharmacy,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -pharmacy,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -pharmacy,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, -pharmacy,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -pharmacy,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -corridor_hospital,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -corridor_hospital,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -corridor_hospital,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -corridor_hospital,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -corridor_hospital,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -corridor_hospital,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -corridor_hospital,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -corridor_hospital,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -corridor_hospital,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -fellowship_hall_religious_facility,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -fellowship_hall_religious_facility,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, -fellowship_hall_religious_facility,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, -fellowship_hall_religious_facility,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -fellowship_hall_religious_facility,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, -fellowship_hall_religious_facility,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0,0,0, -fellowship_hall_religious_facility,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -fellowship_hall_religious_facility,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.05,0.05,0.05, -fellowship_hall_religious_facility,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.475,0.05,0.05,0.05, -lounge_breakroom_healthcare_facility,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -lounge_breakroom_healthcare_facility,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -lounge_breakroom_healthcare_facility,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -lounge_breakroom_healthcare_facility,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -lounge_breakroom_healthcare_facility,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -lounge_breakroom_healthcare_facility,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -lounge_breakroom_healthcare_facility,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, -lounge_breakroom_healthcare_facility,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, -lounge_breakroom_healthcare_facility,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, -operating_room,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -operating_room,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -operating_room,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -operating_room,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.18,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.58,0.45,0.18, -operating_room,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.18,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.58,0.45,0.18, -operating_room,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.18,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.58,0.45,0.18, -operating_room,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -operating_room,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -operating_room,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -physical_therapy,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -physical_therapy,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -physical_therapy,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -physical_therapy,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -physical_therapy,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -physical_therapy,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -physical_therapy,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, -physical_therapy,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, -physical_therapy,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.76,0.9,0.9,0.76,0.76,0.9,0.9,0.9,0.76,0.05,0.05,0.05,0.05,0.05,0.05, -storage_50_to_1000_sf_hospital,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, -storage_50_to_1000_sf_hospital,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, -storage_50_to_1000_sf_hospital,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, -storage_50_to_1000_sf_hospital,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, -storage_50_to_1000_sf_hospital,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, -storage_50_to_1000_sf_hospital,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, -storage_50_to_1000_sf_hospital,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -storage_50_to_1000_sf_hospital,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -storage_50_to_1000_sf_hospital,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -storage_lt_50_sf_hospital,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, -storage_lt_50_sf_hospital,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, -storage_lt_50_sf_hospital,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, -storage_lt_50_sf_hospital,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, -storage_lt_50_sf_hospital,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, -storage_lt_50_sf_hospital,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0, -storage_lt_50_sf_hospital,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -storage_lt_50_sf_hospital,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -storage_lt_50_sf_hospital,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -guest_room,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75,0.9, -guest_room,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75,0.9, -guest_room,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75,0.9, -guest_room,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9, -guest_room,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9, -guest_room,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9, -guest_room,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -guest_room,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -guest_room,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -lobby_hotel,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.3, -lobby_hotel,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.3, -lobby_hotel,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.3, -lobby_hotel,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -lobby_hotel,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -lobby_hotel,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -lobby_hotel,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -lobby_hotel,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -lobby_hotel,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -library_cataloging,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -library_cataloging,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -library_cataloging,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -library_cataloging,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -library_cataloging,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -library_cataloging,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -library_cataloging,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -library_cataloging,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -library_cataloging,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -museum_exhibit_area,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.375,0.45,0.45,0.375,0.375,0.45,0.45,0.7,0.5,0.125,0,0,0,0,0, -museum_exhibit_area,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.375,0.45,0.45,0.375,0.375,0.45,0.45,0.7,0.5,0.125,0,0,0,0,0, -museum_exhibit_area,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.375,0.45,0.45,0.375,0.375,0.45,0.45,0.7,0.5,0.125,0,0,0,0,0, -museum_exhibit_area,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45, -museum_exhibit_area,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45, -museum_exhibit_area,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.45,0.45,0.45,0.45,0.45,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45, -museum_exhibit_area,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.055,0.055,0.055,0.055,0.055,0.05, -museum_exhibit_area,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.055,0.055,0.055,0.055,0.055,0.05, -museum_exhibit_area,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.055,0.055,0.055,0.055,0.055,0.05, -corridor_manufacturing_facility,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -corridor_manufacturing_facility,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -corridor_manufacturing_facility,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -corridor_manufacturing_facility,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -corridor_manufacturing_facility,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -corridor_manufacturing_facility,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -corridor_manufacturing_facility,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.04,0.04,0.04,0.04,0.04,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.04,0.04,0.04, -corridor_manufacturing_facility,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.04,0.04,0.04,0.04,0.04,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.04,0.04,0.04, -corridor_manufacturing_facility,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.04,0.04,0.04,0.04,0.04,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.04,0.04,0.04, -manufacturing_equipment_room,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -manufacturing_equipment_room,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -manufacturing_equipment_room,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -manufacturing_equipment_room,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -manufacturing_equipment_room,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -manufacturing_equipment_room,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -manufacturing_equipment_room,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -manufacturing_equipment_room,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -manufacturing_equipment_room,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -manufacturing_low_bay,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -manufacturing_low_bay,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -manufacturing_low_bay,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -manufacturing_low_bay,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -manufacturing_low_bay,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -manufacturing_low_bay,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -manufacturing_low_bay,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -manufacturing_low_bay,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -manufacturing_low_bay,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -performing_arts_dressing_room,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.825,0,0,0,0,0,0, -performing_arts_dressing_room,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0,0,0,0,0,0, -performing_arts_dressing_room,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0,0,0,0,0,0, -performing_arts_dressing_room,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -performing_arts_dressing_room,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0,0,0,0,0,0, -performing_arts_dressing_room,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0,0,0,0,0,0, -performing_arts_dressing_room,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.045,0.045,0.045,0.045,0.055,0.055,0.055,0.055,0.48,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.475,0.475,0.475,0.045,0.045,0.045, -performing_arts_dressing_room,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.045,0.045,0.045,0.045,0.055,0.055,0.055,0.055,0.48,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.48,0.055,0.055,0.055,0.045,0.045,0.045, -performing_arts_dressing_room,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.045,0.045,0.045,0.045,0.045,0.045,0.045,0.045,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.48,0.055,0.055,0.055,0.045,0.045,0.045, -audience_seating_auditorium,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_auditorium,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_auditorium,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_auditorium,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_auditorium,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_auditorium,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_auditorium,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_auditorium,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_auditorium,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_motion_picture_theater,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_motion_picture_theater,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_motion_picture_theater,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_motion_picture_theater,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_motion_picture_theater,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_motion_picture_theater,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_motion_picture_theater,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_motion_picture_theater,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_motion_picture_theater,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -lobby_motion_picture_theater,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -lobby_motion_picture_theater,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -lobby_motion_picture_theater,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -lobby_motion_picture_theater,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -lobby_motion_picture_theater,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -lobby_motion_picture_theater,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -lobby_motion_picture_theater,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -lobby_motion_picture_theater,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -lobby_motion_picture_theater,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -dwelling_unit,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, -dwelling_unit,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, -dwelling_unit,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0,0,0,0,0,0,0,0,0,0.25,0.75, -dwelling_unit,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0,0,0,0,0,0,0,0,0,0.2,0.2,0.2,0.2,0, -dwelling_unit,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0,0,0,0,0,0,0,0,0,0.2,0.2,0.2,0.2,0, -dwelling_unit,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0,0,0,0,0,0,0,0,0,0.2,0.2,0.2,0.2,0, -dwelling_unit,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -dwelling_unit,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -dwelling_unit,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.53,0.9,0.53,0.07,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.53,0.77,0.9,0.9,0.77,0.3, -museum_restoration,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -museum_restoration,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -museum_restoration,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -museum_restoration,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -museum_restoration,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -museum_restoration,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -museum_restoration,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -museum_restoration,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -museum_restoration,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -banking_activity,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -banking_activity,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -banking_activity,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -banking_activity,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -banking_activity,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -banking_activity,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -banking_activity,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05, -banking_activity,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -banking_activity,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -warehouse_fine_storage,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.45,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.45,0,0,0,0,0,0, -warehouse_fine_storage,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.45,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.45,0,0,0,0,0,0, -warehouse_fine_storage,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.45,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.45,0,0,0,0,0,0, -warehouse_fine_storage,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.45,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.45,0,0,0,0,0,0, -warehouse_fine_storage,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.45,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.45,0,0,0,0,0,0, -warehouse_fine_storage,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.45,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.455,0.45,0,0,0,0,0,0, -warehouse_fine_storage,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -warehouse_fine_storage,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -warehouse_fine_storage,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -classroom_lecture_training_penitentiary,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -classroom_lecture_training_penitentiary,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -classroom_lecture_training_penitentiary,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -classroom_lecture_training_penitentiary,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -classroom_lecture_training_penitentiary,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -classroom_lecture_training_penitentiary,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -classroom_lecture_training_penitentiary,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.04,0.04,0.04,0.04,0.04,0.04,0.04, -classroom_lecture_training_penitentiary,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04, -classroom_lecture_training_penitentiary,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04,0.04, -dining_penitentiary,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0.25,0.9,0.9,0.25,0,0.25,0.9,0.9,0.5,0,0,0.5,0.9,0.9,0.5,0,0,0, -dining_penitentiary,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0.25,0.9,0.9,0.25,0,0.25,0.9,0.9,0.5,0,0,0.5,0.9,0.9,0.5,0,0,0, -dining_penitentiary,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0.25,0.9,0.9,0.25,0,0.25,0.9,0.9,0.5,0,0,0.5,0.9,0.9,0.5,0,0,0, -dining_penitentiary,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0,0.9,0.9,0.9,0.9,0,0,0.9,0.9,0.9,0.9,0,0,0, -dining_penitentiary,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0,0.9,0.9,0.9,0.9,0,0,0.9,0.9,0.9,0.9,0,0,0, -dining_penitentiary,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0,0.9,0.9,0.9,0.9,0,0,0.9,0.9,0.9,0.9,0,0,0, -dining_penitentiary,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.9,0.9,0.3,0.07,0.3,0.9,0.9,0.54,0.07,0.07,0.54,0.9,0.9,0.54,0.07,0.07,0.07, -dining_penitentiary,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.9,0.9,0.3,0.07,0.3,0.9,0.9,0.54,0.07,0.07,0.54,0.9,0.9,0.54,0.07,0.07,0.07, -dining_penitentiary,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.07,0.07,0.07,0.07,0.07,0.07,0.3,0.9,0.9,0.3,0.07,0.3,0.9,0.9,0.54,0.07,0.07,0.54,0.9,0.9,0.54,0.07,0.07,0.07, -audience_seating_performing_arts_theater,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_performing_arts_theater,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_performing_arts_theater,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_performing_arts_theater,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_performing_arts_theater,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_performing_arts_theater,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_performing_arts_theater,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_performing_arts_theater,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_performing_arts_theater,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -lobby_performing_arts_theater,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -lobby_performing_arts_theater,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -lobby_performing_arts_theater,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.75,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.75,0,0,0,0,0,0, -lobby_performing_arts_theater,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -lobby_performing_arts_theater,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -lobby_performing_arts_theater,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -lobby_performing_arts_theater,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -lobby_performing_arts_theater,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -lobby_performing_arts_theater,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -audience_seating_religious_facility,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -audience_seating_religious_facility,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -audience_seating_religious_facility,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -audience_seating_religious_facility,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -audience_seating_religious_facility,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -audience_seating_religious_facility,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -audience_seating_religious_facility,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -audience_seating_religious_facility,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -audience_seating_religious_facility,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -worship_pulpit_choir_area,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -worship_pulpit_choir_area,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -worship_pulpit_choir_area,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -worship_pulpit_choir_area,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0, -worship_pulpit_choir_area,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -worship_pulpit_choir_area,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -worship_pulpit_choir_area,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -worship_pulpit_choir_area,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -worship_pulpit_choir_area,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -classroom_lecture_training_preschool_to_12th,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.1,0.25,0.75,0.9,0.9,0.5,0.5,0.9,0.9,0.5,0.5,0,0,0,0,0,0, -classroom_lecture_training_preschool_to_12th,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -classroom_lecture_training_preschool_to_12th,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -classroom_lecture_training_preschool_to_12th,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -classroom_lecture_training_preschool_to_12th,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -classroom_lecture_training_preschool_to_12th,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -classroom_lecture_training_preschool_to_12th,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05, -classroom_lecture_training_preschool_to_12th,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -classroom_lecture_training_preschool_to_12th,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05, -sports_arena_playing_area_class_ii,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.125,0.25,0.9,0.9,0.9,0.825,0.825,0.9,0.9,0.9,0.7,0.575,0.45,0.45,0,0,0, -sports_arena_playing_area_class_ii,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.825,0.9,0.9,0.825,0.825,0.9,0.9,0.9,0.825,0.45,0.45,0.45,0,0,0, -sports_arena_playing_area_class_ii,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.825,0.9,0.9,0.825,0.825,0.9,0.9,0.9,0.825,0.45,0.45,0.45,0,0,0, -sports_arena_playing_area_class_ii,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.45,0.45,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0,0,0, -sports_arena_playing_area_class_ii,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0.45,0,0,0, -sports_arena_playing_area_class_ii,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.45,0.45,0.45,0,0,0, -sports_arena_playing_area_class_ii,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.475,0.475,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.475,0.05,0.05,0.05, -sports_arena_playing_area_class_ii,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.83,0.9,0.9,0.83,0.83,0.9,0.9,0.9,0.83,0.475,0.475,0.475,0.05,0.05,0.05, -sports_arena_playing_area_class_ii,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.83,0.9,0.9,0.83,0.83,0.9,0.9,0.9,0.83,0.475,0.475,0.475,0.05,0.05,0.05, -audience_seating_sports_arena,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_sports_arena,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_sports_arena,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.5,0.5,0.9,0.9,0.9,0.9,0.67,0, -audience_seating_sports_arena,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_sports_arena,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_sports_arena,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0, -audience_seating_sports_arena,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_sports_arena,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -audience_seating_sports_arena,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.06,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.34, -airport_concourse,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0.25,0.25,0.25,0.25,0.25, -airport_concourse,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0.25,0.25,0.25,0.25,0.25, -airport_concourse,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0.25,0.25,0.25,0.25,0.25, -airport_concourse,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -airport_concourse,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -airport_concourse,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -airport_concourse,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -airport_concourse,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -airport_concourse,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -atrium_lt_20_ft_height,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_lt_20_ft_height,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_lt_20_ft_height,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_lt_20_ft_height,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_lt_20_ft_height,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_lt_20_ft_height,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_lt_20_ft_height,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -atrium_lt_20_ft_height,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -atrium_lt_20_ft_height,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -atrium_gt_40_ft_height,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_gt_40_ft_height,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_gt_40_ft_height,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_gt_40_ft_height,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_gt_40_ft_height,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_gt_40_ft_height,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_gt_40_ft_height,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -atrium_gt_40_ft_height,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -atrium_gt_40_ft_height,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -atrium_gte_20_ft_and_lte_40_ft_in_height,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_gte_20_ft_and_lte_40_ft_in_height,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_gte_20_ft_and_lte_40_ft_in_height,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_gte_20_ft_and_lte_40_ft_in_height,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_gte_20_ft_and_lte_40_ft_in_height,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_gte_20_ft_and_lte_40_ft_in_height,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -atrium_gte_20_ft_and_lte_40_ft_in_height,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -atrium_gte_20_ft_and_lte_40_ft_in_height,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -atrium_gte_20_ft_and_lte_40_ft_in_height,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.05,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.05,0.05,0.05,0.05,0.05,0.05, -baggage_carousel,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0.25,0.25,0.25,0.25,0.25, -baggage_carousel,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0.25,0.25,0.25,0.25,0.25, -baggage_carousel,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0.25,0.25,0.25,0.25,0.25, -baggage_carousel,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -baggage_carousel,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -baggage_carousel,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -baggage_carousel,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -baggage_carousel,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -baggage_carousel,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -seating_area_general,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25,0.25, -seating_area_general,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25,0.25, -seating_area_general,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25,0.25, -seating_area_general,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -seating_area_general,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -seating_area_general,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -seating_area_general,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -seating_area_general,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -seating_area_general,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9, -transportation_ticket_counter,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -transportation_ticket_counter,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -transportation_ticket_counter,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.25,0.5,0.9,0.9,0.9,0.75,0.75,0.9,0.9,0.9,0.5,0.25,0,0,0,0,0, -transportation_ticket_counter,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -transportation_ticket_counter,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -transportation_ticket_counter,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0, -transportation_ticket_counter,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25,0.25,0.25, -transportation_ticket_counter,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25,0.25,0.25, -transportation_ticket_counter,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0.25,0.25,0.25,0.25,0.25,0.25,0.25,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.25,0.25,0.25,0.25,0.25, -warehouse_bulk_storage,Occupancy,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -warehouse_bulk_storage,Occupancy,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -warehouse_bulk_storage,Occupancy,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -warehouse_bulk_storage,Lighting,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -warehouse_bulk_storage,Lighting,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -warehouse_bulk_storage,Lighting,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0.9,0,0,0,0,0,0, -warehouse_bulk_storage,Equipment,,Default|SmrDsn|Wkdy,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -warehouse_bulk_storage,Equipment,,Sat,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, -warehouse_bulk_storage,Equipment,,WntrDsn|Hol|Sun,1/1/2023,12/31/2023,Hourly,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0, diff --git a/data/openstudio_standards_data/database_files/support_standard_templates.csv b/data/openstudio_standards_data/database_files/support_standard_templates.csv deleted file mode 100644 index 38a317f247..0000000000 --- a/data/openstudio_standards_data/database_files/support_standard_templates.csv +++ /dev/null @@ -1,3 +0,0 @@ -template,lighting_standard,lighting_standard_table,ventilation_standard,ventilation_standard_table -90.1-2019,ASHRAE 90.1-2019,level_3_lighting_90_1_2019,ASHRAE 62.1-2019,level_3_ventilation_90_1_2019 -90.1-2004,ASHRAE 90.1-2004,level_3_lighting_90_1_2004,ASHRAE 62.1-2004,level_3_ventilation_90_1_2004 diff --git a/data/openstudio_standards_data/database_files/support_ventilation_space_type_name_tags.csv b/data/openstudio_standards_data/database_files/support_ventilation_space_type_name_tags.csv deleted file mode 100644 index f8145aba7f..0000000000 --- a/data/openstudio_standards_data/database_files/support_ventilation_space_type_name_tags.csv +++ /dev/null @@ -1,99 +0,0 @@ -ventilation_space_type_name -airport_concourse_ventilation -atrium_ventilation -attic_ventilation -audience_seating_ventilation -baggage_carousel_ventilation -banking_ventilation -classroom_lecture_training_ventilation -computer_room_ventilation -conference_meeting_multipurpose_ventilation -confinement_cells_ventilation -copy_print_ventilation -corridor_ventilation -courtroom_ventilation -datacenterhighite_ventilation -datacenterlowite_ventilation -dining_ventilation -dressing_room_ventilation -electrical_mechanical_ventilation -emergency_room_ventilation -exam_treatment_ventilation -exercise_area_ventilation -exhibit_ventilation -guest_room_ventilation -imaging_ventilation -judges_chambers_ventilation -food_preparation_ventilation -laboratory_ventilation -laundry_washing_ventilation -library_ventilation -living_quarters_ventilation -loading_dock_ventilation -lobby_ventilation -locker_room_ventilation -lounge_breakroom_ventilation -manufacturing_ventilation -medical_supply_ventilation -multifamily_ventilation -nursery_ventilation -nurses_station_ventilation -office_ventilation -office_enclosed_ventilation -operating_room_ventilation -patient_room_ventilation -pharmacy_ventilation -physical_therapy_ventilation -playing_area_ventilation -plenum_ventilation -post_office_ventilation -recovery_ventilation -recreation_common_living_ventilation -retail_sales_ventilation -shaft_ventilation -sleeping_quarters_ventilation -sports_arena_ventilation -stairwell_ventilation -storage_ventilation -transportation_ventilation -workshop_ventilation -worship_ventilation -correctional_facilities_booking_waiting_ventilation -correctional_facilities_day_room_ventilation -correctional_facilities_guard_stations_ventilation -educational_facilities_art_classroom_ventilation -educational_facilities_classrooms_ages_5-8_ventilation -educational_facilities_daycare_through_age_4_ventilation -educational_facilities_lecture_classroom_ventilation -educational_facilities_lecture_hall_fixed_seats_ventilation -educational_facilities_media_center_ventilation -educational_facilities_multi-use_assembly_ventilation -educational_facilities_music_theater_dance_ventilation -educational_facilities_science_laboratories_ventilation -educational_facilities_wood_metal_shop_ventilation -food_and_beverage_service_bars_cocktail_lounges_ventilation -food_and_beverage_service_cafeteria_fast_food_dining_ventilation -hotels_motels_resorts_dormitories_lobbies_prefunction_ventilation -miscellaneous_spaces_bank_vaults_safe_deposit_ventilation -miscellaneous_spaces_computer_not_printing_ventilation -miscellaneous_spaces_photo_studios_ventilation -miscellaneous_spaces_warehouses_ventilation -public_assembly_spaces_lobbies_ventilation -public_assembly_spaces_museums_childrens_ventilation -retail_barber_shop_ventilation -retail_beauty_and_nail_salons_ventilation -retail_coin-operated_laundries_ventilation -retail_pet_shops_animal_areas_ventilation -retail_supermarket_ventilation -sports_and_entertainment_bowling_alley_seating_ventilation -sports_and_entertainment_disco_dance_floors_ventilation -sports_and_entertainment_gambling_casinos_ventilation -sports_and_entertainment_game_arcades_ventilation -sports_and_entertainment_health_club_weight_rooms_ventilation -sports_and_entertainment_spectator_areas_ventilation -sports_and_entertainment_stages_studios_ventilation -sports_and_entertainment_swimming_pool_deck_ventilation -emergency_vehicle_garage_ventilation -interior_parking_ventilation -restroom_ventilation -vehicular_maintenance_ventilation diff --git a/data/openstudio_standards_data/database_files/system_requirement_economizer_90_1.csv b/data/openstudio_standards_data/database_files/system_requirement_economizer_90_1.csv deleted file mode 100644 index 1405f86a9d..0000000000 --- a/data/openstudio_standards_data/database_files/system_requirement_economizer_90_1.csv +++ /dev/null @@ -1,497 +0,0 @@ -template,climate_zone,data_center,capacity_limit,fixed_dry_bulb_high_limit_shutoff_temp,annotation -90.1-2004,ASHRAE 169-2006-1A,FALSE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-1A,TRUE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-1B,FALSE,,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-1B,TRUE,,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-2A,FALSE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-2A,TRUE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-2B,FALSE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-2B,TRUE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-3A,FALSE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-3A,TRUE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-3B,FALSE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-3B,TRUE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-3C,FALSE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-3C,TRUE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-4A,FALSE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-4A,TRUE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-4B,FALSE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-4B,TRUE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-4C,FALSE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-4C,TRUE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-5A,FALSE,135000,70,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-5A,TRUE,135000,70,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-5B,FALSE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-5B,TRUE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-5C,FALSE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-5C,TRUE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-6A,FALSE,135000,70,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-6A,TRUE,135000,70,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-6B,FALSE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-6B,TRUE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-7A,FALSE,135000,70,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-7A,TRUE,135000,70,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-7B,FALSE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-7B,TRUE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-8A,FALSE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-8A,TRUE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-8B,FALSE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-8B,TRUE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-1A,FALSE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-1A,TRUE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-1B,FALSE,,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-1B,TRUE,,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-2A,FALSE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-2A,TRUE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-2B,FALSE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-2B,TRUE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-3A,FALSE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-3A,TRUE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-3B,FALSE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-3B,TRUE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-3C,FALSE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-3C,TRUE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-4A,FALSE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-4A,TRUE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-4B,FALSE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-4B,TRUE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-4C,FALSE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-4C,TRUE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-5A,FALSE,135000,70,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-5A,TRUE,135000,70,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-5B,FALSE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-5B,TRUE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-5C,FALSE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-5C,TRUE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-6A,FALSE,135000,70,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-6A,TRUE,135000,70,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-6B,FALSE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-6B,TRUE,65000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-7A,FALSE,135000,70,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-7A,TRUE,135000,70,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-7B,FALSE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-7B,TRUE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-8A,FALSE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-8A,TRUE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-8B,FALSE,135000,75,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-8B,TRUE,135000,75,90.1-2004 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-1A,FALSE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-1A,TRUE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-1B,FALSE,,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-1B,TRUE,,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-2A,FALSE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-2A,TRUE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-2B,FALSE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-2B,TRUE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-3A,FALSE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-3A,TRUE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-3B,FALSE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-3B,TRUE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-3C,FALSE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-3C,TRUE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-4A,FALSE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-4A,TRUE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-4B,FALSE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-4B,TRUE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-4C,FALSE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-4C,TRUE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-5A,FALSE,135000,70,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-5A,TRUE,135000,70,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-5B,FALSE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-5B,TRUE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-5C,FALSE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-5C,TRUE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-6A,FALSE,135000,70,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-6A,TRUE,135000,70,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-6B,FALSE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-6B,TRUE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-7A,FALSE,135000,70,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-7A,TRUE,135000,70,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-7B,FALSE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-7B,TRUE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-8A,FALSE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-8A,TRUE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-8B,FALSE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-8B,TRUE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-1A,FALSE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-1A,TRUE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-1B,FALSE,,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-1B,TRUE,,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-2A,FALSE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-2A,TRUE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-2B,FALSE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-2B,TRUE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-3A,FALSE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-3A,TRUE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-3B,FALSE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-3B,TRUE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-3C,FALSE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-3C,TRUE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-4A,FALSE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-4A,TRUE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-4B,FALSE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-4B,TRUE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-4C,FALSE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-4C,TRUE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-5A,FALSE,135000,70,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-5A,TRUE,135000,70,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-5B,FALSE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-5B,TRUE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-5C,FALSE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-5C,TRUE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-6A,FALSE,135000,70,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-6A,TRUE,135000,70,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-6B,FALSE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-6B,TRUE,65000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-7A,FALSE,135000,70,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-7A,TRUE,135000,70,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-7B,FALSE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-7B,TRUE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-8A,FALSE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-8A,TRUE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-8B,FALSE,135000,75,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-8B,TRUE,135000,75,90.1-2007 Table 6.5.1 -90.1-2010,ASHRAE 169-2006-1A,TRUE,,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-1A,FALSE,,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-1B,TRUE,,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-1B,FALSE,,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-2A,TRUE,,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-2A,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-2B,TRUE,135000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-2B,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-3A,TRUE,,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-3A,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-3B,TRUE,65000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-3B,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-3C,TRUE,65000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-3C,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-4A,TRUE,,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-4A,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-4B,TRUE,65000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-4B,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-4C,TRUE,65000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-4C,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-5A,TRUE,135000,70,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-5A,FALSE,54000,70,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-5B,TRUE,65000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-5B,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-5C,TRUE,65000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-5C,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-6A,TRUE,135000,70,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-6A,FALSE,54000,70,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-6B,TRUE,65000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-6B,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-7A,TRUE,135000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-7A,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-7B,TRUE,135000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-7B,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-8A,TRUE,135000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-8A,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-8B,TRUE,135000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-8B,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-1A,TRUE,,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-1A,FALSE,,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-1B,TRUE,,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-1B,FALSE,,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-2A,TRUE,,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-2A,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-2B,TRUE,135000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-2B,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-3A,TRUE,,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-3A,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-3B,TRUE,65000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-3B,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-3C,TRUE,65000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-3C,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-4A,TRUE,,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-4A,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-4B,TRUE,65000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-4B,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-4C,TRUE,65000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-4C,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-5A,TRUE,135000,70,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-5A,FALSE,54000,70,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-5B,TRUE,65000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-5B,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-5C,TRUE,65000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-5C,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-6A,TRUE,135000,70,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-6A,FALSE,54000,70,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-6B,TRUE,65000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-6B,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-7A,TRUE,135000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-7A,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-7B,TRUE,135000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-7B,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-8A,TRUE,135000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-8A,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-8B,TRUE,135000,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-8B,FALSE,54000,75,90.1-2010 Table 6.5.1A -90.1-2013,ASHRAE 169-2006-1A,TRUE,,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-1A,FALSE,,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-1B,TRUE,,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-1B,FALSE,,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-2A,TRUE,,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-2A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-2B,TRUE,135000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-2B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-3A,TRUE,,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-3A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-3B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-3B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-3C,TRUE,65000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-3C,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-4A,TRUE,,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-4A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-4B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-4B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-4C,TRUE,65000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-4C,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-5A,TRUE,135000,70,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-5A,FALSE,54000,70,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-5B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-5B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-5C,TRUE,65000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-5C,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-6A,TRUE,135000,70,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-6A,FALSE,54000,70,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-6B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-6B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-7A,TRUE,135000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-7A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-7B,TRUE,135000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-7B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-8A,TRUE,135000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-8A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-8B,TRUE,135000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-8B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-1A,TRUE,,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-1A,FALSE,,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-1B,TRUE,,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-1B,FALSE,,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-2A,TRUE,,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-2A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-2B,TRUE,135000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-2B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-3A,TRUE,,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-3A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-3B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-3B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-3C,TRUE,65000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-3C,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-4A,TRUE,,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-4A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-4B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-4B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-4C,TRUE,65000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-4C,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-5A,TRUE,135000,70,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-5A,FALSE,54000,70,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-5B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-5B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-5C,TRUE,65000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-5C,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-6A,TRUE,135000,70,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-6A,FALSE,54000,70,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-6B,TRUE,65000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-6B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-7A,TRUE,135000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-7A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-7B,TRUE,135000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-7B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-8A,TRUE,135000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-8A,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-8B,TRUE,135000,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-8B,FALSE,54000,75,90.1-2013 Table 6.5.1-1 -90.1-2004,ASHRAE 169-2006-0A,FALSE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2006-0B,FALSE,,75,90.1-2004 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-0A,FALSE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2006-0B,FALSE,,75,90.1-2007 Table 6.5.1 -90.1-2010,ASHRAE 169-2006-0A,FALSE,,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2006-0B,FALSE,,75,90.1-2010 Table 6.5.1A -90.1-2013,ASHRAE 169-2006-0A,FALSE,,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2006-0B,FALSE,,75,90.1-2013 Table 6.5.1-1 -90.1-2004,ASHRAE 169-2013-0A,FALSE,,65,90.1-2004 Table 6.5.1 -90.1-2004,ASHRAE 169-2013-0B,FALSE,,75,90.1-2004 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-0A,FALSE,,65,90.1-2007 Table 6.5.1 -90.1-2007,ASHRAE 169-2013-0B,FALSE,,75,90.1-2007 Table 6.5.1 -90.1-2010,ASHRAE 169-2013-0A,FALSE,,75,90.1-2010 Table 6.5.1A -90.1-2010,ASHRAE 169-2013-0B,FALSE,,75,90.1-2010 Table 6.5.1A -90.1-2013,ASHRAE 169-2013-0A,FALSE,,75,90.1-2013 Table 6.5.1-1 -90.1-2013,ASHRAE 169-2013-0B,FALSE,,75,90.1-2013 Table 6.5.1-1 -90.1-2010,ASHRAE 169-2006-0A,TRUE,,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2006-0B,TRUE,,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-0A,TRUE,,75,90.1-2010 Table 6.5.1B -90.1-2010,ASHRAE 169-2013-0B,TRUE,,75,90.1-2010 Table 6.5.1B -90.1-2013,ASHRAE 169-2006-0A,TRUE,,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2006-0B,TRUE,,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-0A,TRUE,,75,90.1-2013 Table 6.5.1-2 -90.1-2013,ASHRAE 169-2013-0B,TRUE,,75,90.1-2013 Table 6.5.1-2 -90.1-2016,ASHRAE 169-2006-1A,TRUE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-1A,FALSE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-1B,TRUE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-1B,FALSE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-2A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-2A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-2B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-2B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-3A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-3A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-3B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-3B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-3C,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-3C,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-4A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-4A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-4B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-4B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-4C,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-4C,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-5A,TRUE,54000,70,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-5A,FALSE,54000,70,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-5B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-5B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-5C,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-5C,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-6A,TRUE,54000,70,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-6A,FALSE,54000,70,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-6B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-6B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-7A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-7A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-7B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-7B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-8A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-8A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-8B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-8B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-1A,TRUE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-1A,FALSE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-1B,TRUE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-1B,FALSE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-2A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-2A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-2B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-2B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-3A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-3A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-3B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-3B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-3C,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-3C,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-4A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-4A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-4B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-4B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-4C,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-4C,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-5A,TRUE,54000,70,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-5A,FALSE,54000,70,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-5B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-5B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-5C,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-5C,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-6A,TRUE,54000,70,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-6A,FALSE,54000,70,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-6B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-6B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-7A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-7A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-7B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-7B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-8A,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-8A,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-8B,TRUE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-8B,FALSE,54000,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-0A,FALSE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-0B,FALSE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-0A,FALSE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-0B,FALSE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-0A,TRUE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2006-0B,TRUE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-0A,TRUE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2016,ASHRAE 169-2013-0B,TRUE,,75,90.1-2016 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-1A,TRUE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-1A,FALSE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-1B,TRUE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-1B,FALSE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-2A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-2A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-2B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-2B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-3A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-3A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-3B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-3B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-3C,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-3C,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-4A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-4A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-4B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-4B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-4C,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-4C,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-5A,TRUE,54000,70,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-5A,FALSE,54000,70,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-5B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-5B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-5C,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-5C,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-6A,TRUE,54000,70,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-6A,FALSE,54000,70,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-6B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-6B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-7A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-7A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-7B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-7B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-8A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-8A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-8B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-8B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-1A,TRUE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-1A,FALSE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-1B,TRUE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-1B,FALSE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-2A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-2A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-2B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-2B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-3A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-3A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-3B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-3B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-3C,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-3C,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-4A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-4A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-4B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-4B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-4C,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-4C,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-5A,TRUE,54000,70,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-5A,FALSE,54000,70,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-5B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-5B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-5C,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-5C,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-6A,TRUE,54000,70,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-6A,FALSE,54000,70,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-6B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-6B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-7A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-7A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-7B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-7B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-8A,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-8A,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-8B,TRUE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-8B,FALSE,54000,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-0A,FALSE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-0B,FALSE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-0A,FALSE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-0B,FALSE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-0A,TRUE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2006-0B,TRUE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-0A,TRUE,,75,90.1-2019 Table 6.5.1.1.3 -90.1-2019,ASHRAE 169-2013-0B,TRUE,,75,90.1-2019 Table 6.5.1.1.3 diff --git a/data/openstudio_standards_data/database_files/system_requirement_energy_recovery_90_1.csv b/data/openstudio_standards_data/database_files/system_requirement_energy_recovery_90_1.csv deleted file mode 100644 index 862acf4361..0000000000 --- a/data/openstudio_standards_data/database_files/system_requirement_energy_recovery_90_1.csv +++ /dev/null @@ -1,409 +0,0 @@ -template,climate_zone,under_8000_hours,nontransient_dwelling,percent_oa_0_to_10,percent_oa_10_to_20,percent_oa_20_to_30,percent_oa_30_to_40,percent_oa_40_to_50,percent_oa_50_to_60,percent_oa_60_to_70,percent_oa_70_to_80,percent_oa_greater_than_80,enthalpy_recovery_ratio_design_conditions,enthalpy_recovery_ratio,annotation -90.1-2010,ASHRAE 169-2006-1A,,,,,,5500,4500,3500,2000,1000,0,,, -90.1-2010,ASHRAE 169-2006-1B,,,,,,,,26000,12000,5000,4000,,, -90.1-2010,ASHRAE 169-2006-2A,,,,,,5500,4500,3500,2000,1000,0,,, -90.1-2010,ASHRAE 169-2006-2B,,,,,,,,26000,12000,5000,4000,,, -90.1-2010,ASHRAE 169-2006-3A,,,,,,5500,4500,3500,2000,1000,0,,, -90.1-2010,ASHRAE 169-2006-3B,,,,,,,,,,5000,5000,,, -90.1-2010,ASHRAE 169-2006-3C,,,,,,,,,,5000,5000,,, -90.1-2010,ASHRAE 169-2006-4A,,,,,,5500,4500,3500,2000,1000,0,,, -90.1-2010,ASHRAE 169-2006-4B,,,,,,,,,,5000,5000,,, -90.1-2010,ASHRAE 169-2006-4C,,,,,,,,,,5000,5000,,, -90.1-2010,ASHRAE 169-2006-5A,,,,,,5500,4500,3500,2000,1000,0,,, -90.1-2010,ASHRAE 169-2006-5B,,,,,,,,,,5000,5000,,, -90.1-2010,ASHRAE 169-2006-5C,,,,,,,,26000,12000,5000,4000,,, -90.1-2010,ASHRAE 169-2006-6A,,,,,,5500,4500,3500,2000,1000,0,,, -90.1-2010,ASHRAE 169-2006-6B,,,,,,11000,5500,4500,3500,2500,1500,,, -90.1-2010,ASHRAE 169-2006-7A,,,,,,2500,1000,0,0,0,0,,, -90.1-2010,ASHRAE 169-2006-7B,,,,,,2500,1000,0,0,0,0,,, -90.1-2010,ASHRAE 169-2006-8A,,,,,,2500,1000,0,0,0,0,,, -90.1-2010,ASHRAE 169-2006-8B,,,,,,2500,1000,0,0,0,0,,, -90.1-2010,ASHRAE 169-2013-1A,,,,,,5500,4500,3500,2000,1000,0,,, -90.1-2010,ASHRAE 169-2013-1B,,,,,,,,26000,12000,5000,4000,,, -90.1-2010,ASHRAE 169-2013-2A,,,,,,5500,4500,3500,2000,1000,0,,, -90.1-2010,ASHRAE 169-2013-2B,,,,,,,,26000,12000,5000,4000,,, -90.1-2010,ASHRAE 169-2013-3A,,,,,,5500,4500,3500,2000,1000,0,,, -90.1-2010,ASHRAE 169-2013-3B,,,,,,,,,,5000,5000,,, -90.1-2010,ASHRAE 169-2013-3C,,,,,,,,,,5000,5000,,, -90.1-2010,ASHRAE 169-2013-4A,,,,,,5500,4500,3500,2000,1000,0,,, -90.1-2010,ASHRAE 169-2013-4B,,,,,,,,,,5000,5000,,, -90.1-2010,ASHRAE 169-2013-4C,,,,,,,,,,5000,5000,,, -90.1-2010,ASHRAE 169-2013-5A,,,,,,5500,4500,3500,2000,1000,0,,, -90.1-2010,ASHRAE 169-2013-5B,,,,,,,,,,5000,5000,,, -90.1-2010,ASHRAE 169-2013-5C,,,,,,,,26000,12000,5000,4000,,, -90.1-2010,ASHRAE 169-2013-6A,,,,,,5500,4500,3500,2000,1000,0,,, -90.1-2010,ASHRAE 169-2013-6B,,,,,,11000,5500,4500,3500,2500,1500,,, -90.1-2010,ASHRAE 169-2013-7A,,,,,,2500,1000,0,0,0,0,,, -90.1-2010,ASHRAE 169-2013-7B,,,,,,2500,1000,0,0,0,0,,, -90.1-2010,ASHRAE 169-2013-8A,,,,,,2500,1000,0,0,0,0,,, -90.1-2010,ASHRAE 169-2013-8B,,,,,,2500,1000,0,0,0,0,,, -90.1-2013,ASHRAE 169-2006-1A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,,, -90.1-2013,ASHRAE 169-2006-1A,FALSE,,,2500,2000,1000,500,0,0,0,0,,, -90.1-2013,ASHRAE 169-2006-1B,TRUE,,,,,,,26000,12000,5000,4000,,, -90.1-2013,ASHRAE 169-2006-1B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,,, -90.1-2013,ASHRAE 169-2006-2A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,,, -90.1-2013,ASHRAE 169-2006-2A,FALSE,,,2500,2000,1000,500,0,0,0,0,,, -90.1-2013,ASHRAE 169-2006-2B,TRUE,,,,,,,26000,12000,5000,4000,,, -90.1-2013,ASHRAE 169-2006-2B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,,, -90.1-2013,ASHRAE 169-2006-3A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,,, -90.1-2013,ASHRAE 169-2006-3A,FALSE,,,2500,2000,1000,500,0,0,0,0,,, -90.1-2013,ASHRAE 169-2006-3B,TRUE,,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2006-3B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,,, -90.1-2013,ASHRAE 169-2006-3C,TRUE,,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2006-3C,FALSE,,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2006-4A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,,, -90.1-2013,ASHRAE 169-2006-4A,FALSE,,,0,0,0,0,0,0,0,0,,, -90.1-2013,ASHRAE 169-2006-4B,TRUE,,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2006-4B,FALSE,,,2500,2000,1000,500,0,0,0,0,,, -90.1-2013,ASHRAE 169-2006-4C,TRUE,,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2006-4C,FALSE,,,,19500,9000,5000,4000,3000,1500,0,,, -90.1-2013,ASHRAE 169-2006-5A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,,, -90.1-2013,ASHRAE 169-2006-5A,FALSE,,,0,0,0,0,0,0,0,0,,, -90.1-2013,ASHRAE 169-2006-5B,TRUE,,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2006-5B,FALSE,,,2500,2000,1000,500,0,0,0,0,,, -90.1-2013,ASHRAE 169-2006-5C,TRUE,,,,,,,26000,12000,5000,4000,,, -90.1-2013,ASHRAE 169-2006-5C,FALSE,,,,19500,9000,5000,4000,3000,1500,0,,, -90.1-2013,ASHRAE 169-2006-6A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,,, -90.1-2013,ASHRAE 169-2006-6A,FALSE,,,0,0,0,0,0,0,0,0,,, -90.1-2013,ASHRAE 169-2006-6B,TRUE,,,28000,26500,11000,5500,4500,3500,2500,1500,,, -90.1-2013,ASHRAE 169-2006-6B,FALSE,,,0,0,0,0,0,0,0,0,,, -90.1-2013,ASHRAE 169-2006-7A,TRUE,,,4500,4000,2500,1000,0,0,0,0,,, -90.1-2013,ASHRAE 169-2006-7A,FALSE,,,0,0,0,0,0,0,0,0,,, -90.1-2013,ASHRAE 169-2006-7B,TRUE,,,4500,4000,2500,1000,0,0,0,0,,, -90.1-2013,ASHRAE 169-2006-7B,FALSE,,,0,0,0,0,0,0,0,0,,, -90.1-2013,ASHRAE 169-2006-8A,TRUE,,,4500,4000,2500,1000,0,0,0,0,,, -90.1-2013,ASHRAE 169-2006-8A,FALSE,,,0,0,0,0,0,0,0,0,,, -90.1-2013,ASHRAE 169-2006-8B,TRUE,,,4500,4000,2500,1000,0,0,0,0,,, -90.1-2013,ASHRAE 169-2006-8B,FALSE,,,0,0,0,0,0,0,0,0,,, -90.1-2013,ASHRAE 169-2013-1A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,,, -90.1-2013,ASHRAE 169-2013-1A,FALSE,,,2500,2000,1000,500,0,0,0,0,,, -90.1-2013,ASHRAE 169-2013-1B,TRUE,,,,,,,26000,12000,5000,4000,,, -90.1-2013,ASHRAE 169-2013-1B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,,, -90.1-2013,ASHRAE 169-2013-2A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,,, -90.1-2013,ASHRAE 169-2013-2A,FALSE,,,2500,2000,1000,500,0,0,0,0,,, -90.1-2013,ASHRAE 169-2013-2B,TRUE,,,,,,,26000,12000,5000,4000,,, -90.1-2013,ASHRAE 169-2013-2B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,,, -90.1-2013,ASHRAE 169-2013-3A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,,, -90.1-2013,ASHRAE 169-2013-3A,FALSE,,,2500,2000,1000,500,0,0,0,0,,, -90.1-2013,ASHRAE 169-2013-3B,TRUE,,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2013-3B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,,, -90.1-2013,ASHRAE 169-2013-3C,TRUE,,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2013-3C,FALSE,,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2013-4A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,,, -90.1-2013,ASHRAE 169-2013-4A,FALSE,,,0,0,0,0,0,0,0,0,,, -90.1-2013,ASHRAE 169-2013-4B,TRUE,,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2013-4B,FALSE,,,2500,2000,1000,500,0,0,0,0,,, -90.1-2013,ASHRAE 169-2013-4C,TRUE,,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2013-4C,FALSE,,,,19500,9000,5000,4000,3000,1500,0,,, -90.1-2013,ASHRAE 169-2013-5A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,,, -90.1-2013,ASHRAE 169-2013-5A,FALSE,,,0,0,0,0,0,0,0,0,,, -90.1-2013,ASHRAE 169-2013-5B,TRUE,,,,,,,,,,,,, -90.1-2013,ASHRAE 169-2013-5B,FALSE,,,2500,2000,1000,500,0,0,0,0,,, -90.1-2013,ASHRAE 169-2013-5C,TRUE,,,,,,,26000,12000,5000,4000,,, -90.1-2013,ASHRAE 169-2013-5C,FALSE,,,,19500,9000,5000,4000,3000,1500,0,,, -90.1-2013,ASHRAE 169-2013-6A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,,, -90.1-2013,ASHRAE 169-2013-6A,FALSE,,,0,0,0,0,0,0,0,0,,, -90.1-2013,ASHRAE 169-2013-6B,TRUE,,,28000,26500,11000,5500,4500,3500,2500,1500,,, -90.1-2013,ASHRAE 169-2013-6B,FALSE,,,0,0,0,0,0,0,0,0,,, -90.1-2013,ASHRAE 169-2013-7A,TRUE,,,4500,4000,2500,1000,0,0,0,0,,, -90.1-2013,ASHRAE 169-2013-7A,FALSE,,,0,0,0,0,0,0,0,0,,, -90.1-2013,ASHRAE 169-2013-7B,TRUE,,,4500,4000,2500,1000,0,0,0,0,,, -90.1-2013,ASHRAE 169-2013-7B,FALSE,,,0,0,0,0,0,0,0,0,,, -90.1-2013,ASHRAE 169-2013-8A,TRUE,,,4500,4000,2500,1000,0,0,0,0,,, -90.1-2013,ASHRAE 169-2013-8A,FALSE,,,0,0,0,0,0,0,0,0,,, -90.1-2013,ASHRAE 169-2013-8B,TRUE,,,4500,4000,2500,1000,0,0,0,0,,, -90.1-2013,ASHRAE 169-2013-8B,FALSE,,,0,0,0,0,0,0,0,0,,, -90.1-2016,ASHRAE 169-2006-1A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, -90.1-2016,ASHRAE 169-2006-1A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, -90.1-2016,ASHRAE 169-2006-1B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5, -90.1-2016,ASHRAE 169-2006-1B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, -90.1-2016,ASHRAE 169-2006-2A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, -90.1-2016,ASHRAE 169-2006-2A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, -90.1-2016,ASHRAE 169-2006-2B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5, -90.1-2016,ASHRAE 169-2006-2B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, -90.1-2016,ASHRAE 169-2006-3A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, -90.1-2016,ASHRAE 169-2006-3A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, -90.1-2016,ASHRAE 169-2006-3B,TRUE,,,,,,,,,,,Cooling,0.5, -90.1-2016,ASHRAE 169-2006-3B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, -90.1-2016,ASHRAE 169-2006-3C,TRUE,,,,,,,,,,,Heating,0.5, -90.1-2016,ASHRAE 169-2006-3C,FALSE,,,,,,,,,,,Heating,0.5, -90.1-2016,ASHRAE 169-2006-4A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, -90.1-2016,ASHRAE 169-2006-4A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5, -90.1-2016,ASHRAE 169-2006-4B,TRUE,,,,,,,,,,,Cooling,0.5, -90.1-2016,ASHRAE 169-2006-4B,TRUE,,,,,,,,,,,Heating,0.5, -90.1-2016,ASHRAE 169-2006-4B,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, -90.1-2016,ASHRAE 169-2006-4B,FALSE,,,2500,2000,1000,500,140,120,100,80,Heating,0.5, -90.1-2016,ASHRAE 169-2006-4C,TRUE,,,,,,,,,,,Heating,0.5, -90.1-2016,ASHRAE 169-2006-4C,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5, -90.1-2016,ASHRAE 169-2006-5A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, -90.1-2016,ASHRAE 169-2006-5A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5, -90.1-2016,ASHRAE 169-2006-5B,TRUE,,,,,,,,,,,Heating,0.5, -90.1-2016,ASHRAE 169-2006-5B,FALSE,,,2500,2000,1000,500,140,120,100,80,Heating,0.5, -90.1-2016,ASHRAE 169-2006-5C,TRUE,,,,,,,26000,12000,5000,4000,Heating,0.5, -90.1-2016,ASHRAE 169-2006-5C,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5, -90.1-2016,ASHRAE 169-2006-6A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, -90.1-2016,ASHRAE 169-2006-6A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5, -90.1-2016,ASHRAE 169-2006-6B,TRUE,,,28000,26500,11000,5500,4500,3500,2500,1500,Heating,0.5, -90.1-2016,ASHRAE 169-2006-6B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5, -90.1-2016,ASHRAE 169-2006-7A,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, -90.1-2016,ASHRAE 169-2006-7A,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5, -90.1-2016,ASHRAE 169-2006-7B,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, -90.1-2016,ASHRAE 169-2006-7B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5, -90.1-2016,ASHRAE 169-2006-8A,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, -90.1-2016,ASHRAE 169-2006-8A,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5, -90.1-2016,ASHRAE 169-2006-8B,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, -90.1-2016,ASHRAE 169-2006-8B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5, -90.1-2016,ASHRAE 169-2013-1A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, -90.1-2016,ASHRAE 169-2013-1A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, -90.1-2016,ASHRAE 169-2013-1B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5, -90.1-2016,ASHRAE 169-2013-1B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, -90.1-2016,ASHRAE 169-2013-2A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, -90.1-2016,ASHRAE 169-2013-2A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, -90.1-2016,ASHRAE 169-2013-2B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5, -90.1-2016,ASHRAE 169-2013-2B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, -90.1-2016,ASHRAE 169-2013-3A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, -90.1-2016,ASHRAE 169-2013-3A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, -90.1-2016,ASHRAE 169-2013-3B,TRUE,,,,,,,,,,,Cooling,0.5, -90.1-2016,ASHRAE 169-2013-3B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, -90.1-2016,ASHRAE 169-2013-3C,TRUE,,,,,,,,,,,Heating,0.5, -90.1-2016,ASHRAE 169-2013-3C,FALSE,,,,,,,,,,,Heating,0.5, -90.1-2016,ASHRAE 169-2013-4A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, -90.1-2016,ASHRAE 169-2013-4A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5, -90.1-2016,ASHRAE 169-2013-4B,TRUE,,,,,,,,,,,Cooling,0.5, -90.1-2016,ASHRAE 169-2013-4B,TRUE,,,,,,,,,,,Heating,0.5, -90.1-2016,ASHRAE 169-2013-4B,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, -90.1-2016,ASHRAE 169-2013-4B,FALSE,,,2500,2000,1000,500,140,120,100,80,Heating,0.5, -90.1-2016,ASHRAE 169-2013-4C,TRUE,,,,,,,,,,,Heating,0.5, -90.1-2016,ASHRAE 169-2013-4C,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5, -90.1-2016,ASHRAE 169-2013-5A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, -90.1-2016,ASHRAE 169-2013-5A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5, -90.1-2016,ASHRAE 169-2013-5B,TRUE,,,,,,,,,,,Heating,0.5, -90.1-2016,ASHRAE 169-2013-5B,FALSE,,,2500,2000,1000,500,140,120,100,80,Heating,0.5, -90.1-2016,ASHRAE 169-2013-5C,TRUE,,,,,,,26000,12000,5000,4000,Heating,0.5, -90.1-2016,ASHRAE 169-2013-5C,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5, -90.1-2016,ASHRAE 169-2013-6A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, -90.1-2016,ASHRAE 169-2013-6A,FALSE,,,200,130,100,80,70,60,50,40,Cooling,0.5, -90.1-2016,ASHRAE 169-2013-6B,TRUE,,,28000,26500,11000,5500,4500,3500,2500,1500,Heating,0.5, -90.1-2016,ASHRAE 169-2013-6B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5, -90.1-2016,ASHRAE 169-2013-7A,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, -90.1-2016,ASHRAE 169-2013-7A,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5, -90.1-2016,ASHRAE 169-2013-7B,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, -90.1-2016,ASHRAE 169-2013-7B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5, -90.1-2016,ASHRAE 169-2013-8A,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, -90.1-2016,ASHRAE 169-2013-8A,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5, -90.1-2016,ASHRAE 169-2013-8B,TRUE,,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, -90.1-2016,ASHRAE 169-2013-8B,FALSE,,,200,130,100,80,70,60,50,40,Heating,0.5, -90.1-2019,ASHRAE 169-2006-1A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-1A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-1A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-1A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-1B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-1B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-1B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-1B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-2A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-2A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-2A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-2A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-2B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-2B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-2B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-2B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-3A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-3A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-3A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5, -90.1-2019,ASHRAE 169-2006-3A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-3A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-3A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5, -90.1-2019,ASHRAE 169-2006-3B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-3B,TRUE,FALSE,,,,,,,,,,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-3B,TRUE,FALSE,,,,,,,,,,Heating,0.5, -90.1-2019,ASHRAE 169-2006-3B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-3B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-3B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5, -90.1-2019,ASHRAE 169-2006-3C,TRUE,TRUE,,,,,,,,,,,, -90.1-2019,ASHRAE 169-2006-3C,TRUE,FALSE,,,,,,,,,,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-3C,TRUE,FALSE,,,,,,,,,,Heating,0.5, -90.1-2019,ASHRAE 169-2006-3C,FALSE,TRUE,,,,,,,,,,,, -90.1-2019,ASHRAE 169-2006-3C,FALSE,FALSE,,,,,,,,,,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-3C,FALSE,FALSE,,,,,,,,,,Heating,0.5, -90.1-2019,ASHRAE 169-2006-4A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2006-4A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-4A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5, -90.1-2019,ASHRAE 169-2006-4A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2006-4A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-4A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, -90.1-2019,ASHRAE 169-2006-4B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2006-4B,TRUE,FALSE,,,,,,,,,,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-4B,TRUE,FALSE,,,,,,,,,,Heating,0.5, -90.1-2019,ASHRAE 169-2006-4B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2006-4B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-4B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5, -90.1-2019,ASHRAE 169-2006-4C,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2006-4C,TRUE,FALSE,,,,,,,,,,Heating,0.5, -90.1-2019,ASHRAE 169-2006-4C,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2006-4C,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5, -90.1-2019,ASHRAE 169-2006-5A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2006-5A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-5A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5, -90.1-2019,ASHRAE 169-2006-5A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2006-5A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-5A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, -90.1-2019,ASHRAE 169-2006-5B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2006-5B,TRUE,FALSE,,,,,,,,,,Heating,0.5, -90.1-2019,ASHRAE 169-2006-5B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2006-5B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5, -90.1-2019,ASHRAE 169-2006-5C,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2006-5C,TRUE,FALSE,,,,,,26000,12000,5000,4000,Heating,0.5, -90.1-2019,ASHRAE 169-2006-5C,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2006-5C,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5, -90.1-2019,ASHRAE 169-2006-6A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2006-6A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-6A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5, -90.1-2019,ASHRAE 169-2006-6A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2006-6A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-6A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, -90.1-2019,ASHRAE 169-2006-6B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2006-6B,TRUE,FALSE,,28000,26500,11000,5500,4500,3500,2500,1500,Heating,0.5, -90.1-2019,ASHRAE 169-2006-6B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2006-6B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, -90.1-2019,ASHRAE 169-2006-7A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2006-7A,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, -90.1-2019,ASHRAE 169-2006-7A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2006-7A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, -90.1-2019,ASHRAE 169-2006-7B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2006-7B,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, -90.1-2019,ASHRAE 169-2006-7B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2006-7B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, -90.1-2019,ASHRAE 169-2006-8A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2006-8A,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, -90.1-2019,ASHRAE 169-2006-8A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2006-8A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, -90.1-2019,ASHRAE 169-2006-8B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2006-8B,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, -90.1-2019,ASHRAE 169-2006-8B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2006-8B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, -90.1-2019,ASHRAE 169-2013-1A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-1A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-1A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-1A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-1B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-1B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-1B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-1B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-2A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-2A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-2A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-2A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-2B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-2B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-2B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-2B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-3A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-3A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-3A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5, -90.1-2019,ASHRAE 169-2013-3A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-3A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-3A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5, -90.1-2019,ASHRAE 169-2013-3B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-3B,TRUE,FALSE,,,,,,,,,,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-3B,TRUE,FALSE,,,,,,,,,,Heating,0.5, -90.1-2019,ASHRAE 169-2013-3B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-3B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-3B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5, -90.1-2019,ASHRAE 169-2013-3C,TRUE,TRUE,,,,,,,,,,,, -90.1-2019,ASHRAE 169-2013-3C,TRUE,FALSE,,,,,,,,,,Heating,0.5, -90.1-2019,ASHRAE 169-2013-3C,FALSE,TRUE,,,,,,,,,,,, -90.1-2019,ASHRAE 169-2013-3C,FALSE,FALSE,,,,,,,,,,Heating,0.5, -90.1-2019,ASHRAE 169-2013-4A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2013-4A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-4A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5, -90.1-2019,ASHRAE 169-2013-4A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2013-4A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-4A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, -90.1-2019,ASHRAE 169-2013-4B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2013-4B,TRUE,FALSE,,,,,,,,,,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-4B,TRUE,FALSE,,,,,,,,,,Heating,0.5, -90.1-2019,ASHRAE 169-2013-4B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2013-4B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-4B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5, -90.1-2019,ASHRAE 169-2013-4C,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2013-4C,TRUE,FALSE,,,,,,,,,,Heating,0.5, -90.1-2019,ASHRAE 169-2013-4C,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2013-4C,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5, -90.1-2019,ASHRAE 169-2013-5A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2013-5A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-5A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5, -90.1-2019,ASHRAE 169-2013-5A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2013-5A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-5A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, -90.1-2019,ASHRAE 169-2013-5B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2013-5B,TRUE,FALSE,,,,,,,,,,Heating,0.5, -90.1-2019,ASHRAE 169-2013-5B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2013-5B,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Heating,0.5, -90.1-2019,ASHRAE 169-2013-5C,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2013-5C,TRUE,FALSE,,,,,,26000,12000,5000,4000,Heating,0.5, -90.1-2019,ASHRAE 169-2013-5C,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2013-5C,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Heating,0.5, -90.1-2019,ASHRAE 169-2013-6A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2013-6A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-6A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Heating,0.5, -90.1-2019,ASHRAE 169-2013-6A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2013-6A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-6A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, -90.1-2019,ASHRAE 169-2013-6B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2013-6B,TRUE,FALSE,,28000,26500,11000,5500,4500,3500,2500,1500,Heating,0.5, -90.1-2019,ASHRAE 169-2013-6B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2013-6B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, -90.1-2019,ASHRAE 169-2013-7A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2013-7A,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, -90.1-2019,ASHRAE 169-2013-7A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2013-7A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, -90.1-2019,ASHRAE 169-2013-7B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2013-7B,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, -90.1-2019,ASHRAE 169-2013-7B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2013-7B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, -90.1-2019,ASHRAE 169-2013-8A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2013-8A,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, -90.1-2019,ASHRAE 169-2013-8A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2013-8A,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, -90.1-2019,ASHRAE 169-2013-8B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2013-8B,TRUE,FALSE,,4500,4000,2500,1000,140,120,100,80,Heating,0.5, -90.1-2019,ASHRAE 169-2013-8B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Heating,0.6, -90.1-2019,ASHRAE 169-2013-8B,FALSE,FALSE,,200,130,100,80,70,60,50,40,Heating,0.5, -90.1-2010,ASHRAE 169-2006-0A,,,,,,5500,4500,3500,2000,1000,0,,, -90.1-2010,ASHRAE 169-2006-0B,,,,,,,,26000,12000,5000,4000,,, -90.1-2010,ASHRAE 169-2013-0A,,,,,,5500,4500,3500,2000,1000,0,,, -90.1-2010,ASHRAE 169-2013-0B,,,,,,,,26000,12000,5000,4000,,, -90.1-2013,ASHRAE 169-2006-0A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,,, -90.1-2013,ASHRAE 169-2006-0A,FALSE,,,2500,2000,1000,500,0,0,0,0,,, -90.1-2013,ASHRAE 169-2006-0B,TRUE,,,,,,,26000,12000,5000,4000,,, -90.1-2013,ASHRAE 169-2006-0B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,,, -90.1-2013,ASHRAE 169-2013-0A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,0,,, -90.1-2013,ASHRAE 169-2013-0A,FALSE,,,2500,2000,1000,500,0,0,0,0,,, -90.1-2013,ASHRAE 169-2013-0B,TRUE,,,,,,,26000,12000,5000,4000,,, -90.1-2013,ASHRAE 169-2013-0B,FALSE,,,,19500,9000,5000,4000,3000,1500,0,,, -90.1-2016,ASHRAE 169-2006-0A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, -90.1-2016,ASHRAE 169-2006-0A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, -90.1-2016,ASHRAE 169-2006-0B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5, -90.1-2016,ASHRAE 169-2006-0B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, -90.1-2016,ASHRAE 169-2013-0A,TRUE,,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, -90.1-2016,ASHRAE 169-2013-0A,FALSE,,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, -90.1-2016,ASHRAE 169-2013-0B,TRUE,,,,,,,26000,12000,5000,4000,Cooling,0.5, -90.1-2016,ASHRAE 169-2013-0B,FALSE,,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-0A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-0A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-0A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-0A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-0B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-0B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-0B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2006-0B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-0A,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-0A,TRUE,FALSE,,26000,16000,5500,4500,3500,2000,1000,120,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-0A,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-0A,FALSE,FALSE,,2500,2000,1000,500,140,120,100,80,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-0B,TRUE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-0B,TRUE,FALSE,,,,,,26000,12000,5000,4000,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-0B,FALSE,TRUE,0,0,0,0,0,0,0,0,0,Cooling,0.5, -90.1-2019,ASHRAE 169-2013-0B,FALSE,FALSE,,,19500,9000,5000,4000,3000,1500,120,Cooling,0.5, From f56befb36210528a71d826014cb26160aec2781b Mon Sep 17 00:00:00 2001 From: "Lerond, Jeremy" Date: Tue, 9 May 2023 13:03:51 -0700 Subject: [PATCH 24/45] Revert changes to medium office OSM. --- data/geometry/ASHRAEMediumOffice.osm | 10 +++++----- 1 file changed, 5 insertions(+), 5 deletions(-) diff --git a/data/geometry/ASHRAEMediumOffice.osm b/data/geometry/ASHRAEMediumOffice.osm index 7e6984e7f4..b377f9c93f 100644 --- a/data/geometry/ASHRAEMediumOffice.osm +++ b/data/geometry/ASHRAEMediumOffice.osm @@ -4452,30 +4452,30 @@ OS:ZoneHVAC:EquipmentList, OS:SpaceType, {34e15ad4-259e-4af7-9d47-f9dfb6b78bc5}, !- Handle - Office, !- Name + Office WholeBuilding - Md Office, !- Name , !- Default Construction Set Name , !- Default Schedule Set Name {507a5052-c6fa-4e80-96ea-d8413460cc49}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Office, !- Standards Building Type - Office; !- Standards Space Type + WholeBuilding - Md Office; !- Standards Space Type OS:Rendering:Color, {507a5052-c6fa-4e80-96ea-d8413460cc49}, !- Handle - Office, !- Name + Office WholeBuilding - Md Office, !- Name 120, !- Rendering Red Value 230, !- Rendering Green Value 199; !- Rendering Blue Value OS:SpaceType, {197e68ab-195b-4ad3-9452-c3b5ed7c640d}, !- Handle - Corridor, !- Name + Plenum, !- Name , !- Default Construction Set Name , !- Default Schedule Set Name , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name , !- Standards Building Type - Corridor; !- Standards Space Type + Plenum; !- Standards Space Type OS:SubSurface, {bc65ca32-39bf-48a6-a1cd-d61dc5fd3db7}, !- Handle From 3c788e664520568894a4d1473d4d012b9da856b6 Mon Sep 17 00:00:00 2001 From: "Lerond, Jeremy" Date: Tue, 9 May 2023 13:08:59 -0700 Subject: [PATCH 25/45] update gitignore. --- .gitignore | 1 + 1 file changed, 1 insertion(+) diff --git a/.gitignore b/.gitignore index fba952516a..f78c286963 100644 --- a/.gitignore +++ b/.gitignore @@ -48,6 +48,7 @@ coverage/ /data/standards/openstudio_standards_duplicates_log.csv /data/standards/export /data/geometry/../*.osw +/data/openstudio_standards_data/Pipfile.lock ## Python ignores # Byte-compiled / optimized / DLL files From 1bd64d424121af21a9767a73e8f9eb62663f660c Mon Sep 17 00:00:00 2001 From: Weili Xu Date: Tue, 30 May 2023 12:43:20 -0700 Subject: [PATCH 26/45] remove acrynom header for space type data --- .../create_openstudio_standards_json.py | 12 ++++++------ .../query/fetch/space.py | 18 +++++++++--------- 2 files changed, 15 insertions(+), 15 deletions(-) diff --git a/data/openstudio_standards_data/applications/create_openstudio_standards_json.py b/data/openstudio_standards_data/applications/create_openstudio_standards_json.py index 429e403e7b..a336b8a6a7 100644 --- a/data/openstudio_standards_data/applications/create_openstudio_standards_json.py +++ b/data/openstudio_standards_data/applications/create_openstudio_standards_json.py @@ -92,7 +92,7 @@ def create_openstudio_standards_space_data_json( rec for rec in space_map_table if f"{code.replace('ashrae_', '')}_{code_version}" - in rec["LS.level_3_lighting_code_definition_table"] + in rec["level_3_lighting_code_definition_table"] ] space_types = {"space_types": []} @@ -101,7 +101,7 @@ def create_openstudio_standards_space_data_json( space_type_name = space_type_infos["space_type_name"] if not space_type_name in space_type_names: space_type_names.append(space_type_name) - lighting_space_type_name = space_type_infos["BS.lighting_space_type_name"] + lighting_space_type_name = space_type_infos["lighting_space_type_name"] space_type_data = {"template": template, "space_type": space_type_name} # Get lighting space type data @@ -168,7 +168,7 @@ def create_openstudio_standards_space_data_json( # Get equipment space type data electric_equipment_space_type_name = space_type_infos[ - "ES.electric_equipment_space_type_name" + "electric_equipment_space_type_name" ] electric_equipment_space_type_data = fetch_records_from_table_by_key_values( conn, @@ -202,7 +202,7 @@ def create_openstudio_standards_space_data_json( space_type_data[f] = 0.0 natural_gas_equipment_space_type_name = space_type_infos[ - "EGS.natural_gas_equipment_space_type_name" + "natural_gas_equipment_space_type_name" ] natural_gas_equipment_space_type_data = fetch_records_from_table_by_key_values( conn, @@ -236,7 +236,7 @@ def create_openstudio_standards_space_data_json( # Get ventilation and occupancy space type data ventilation_space_type_name = space_type_infos[ - "BS.ventilation_space_type_name" + "ventilation_space_type_name" ] ventilation_space_type_data = fetch_records_from_table_by_key_values( conn, @@ -280,7 +280,7 @@ def create_openstudio_standards_space_data_json( ] = occ_per_area # assume unit is people / 1000 ft2; TODO: unit check # Schedules - schedule_set_name = space_type_infos["BS.schedule_set_name"] + schedule_set_name = space_type_infos["schedule_set_name"] space_type_data[ "electric_equipment_schedule" ] = f"{schedule_set_name}_equipment" diff --git a/data/openstudio_standards_data/query/fetch/space.py b/data/openstudio_standards_data/query/fetch/space.py index 6e912661b3..be8ca133c1 100644 --- a/data/openstudio_standards_data/query/fetch/space.py +++ b/data/openstudio_standards_data/query/fetch/space.py @@ -8,15 +8,15 @@ SPACE_DATA_HEADER = [ "space_type_name", - "BS.lighting_space_type_name", - "BS.ventilation_space_type_name", - "LS.level_3_lighting_code_definition_table", - "LS.level_3_lighting_code_definition_id", - "VS.level_3_ventilation_definition_table", - "VS.level_3_ventilation_definition_id", - "ES.electric_equipment_space_type_name", - "EGS.natural_gas_equipment_space_type_name", - "BS.schedule_set_name", + "lighting_space_type_name", + "ventilation_space_type_name", + "level_3_lighting_code_definition_table", + "level_3_lighting_code_definition_id", + "level_3_ventilation_definition_table", + "level_3_ventilation_definition_id", + "electric_equipment_space_type_name", + "natural_gas_equipment_space_type_name", + "schedule_set_name", ] From 3e1eff3df547b6dfedb20f3ad83870582bac3388 Mon Sep 17 00:00:00 2001 From: Weili Xu Date: Tue, 30 May 2023 15:23:50 -0700 Subject: [PATCH 27/45] Fix bug that create database crash due to no such table --- data/openstudio_standards_data/database_engine/assertions.py | 4 ++++ data/openstudio_standards_data/database_tables/__init__.py | 2 +- 2 files changed, 5 insertions(+), 1 deletion(-) diff --git a/data/openstudio_standards_data/database_engine/assertions.py b/data/openstudio_standards_data/database_engine/assertions.py index bf1cf0bc6f..fcc392e3fa 100644 --- a/data/openstudio_standards_data/database_engine/assertions.py +++ b/data/openstudio_standards_data/database_engine/assertions.py @@ -1,3 +1,6 @@ +import logging + + class OpenStudioStandardsDataException(Exception): def __init__(self, message): super().__init__(message) @@ -10,6 +13,7 @@ def __init__(self, message): def assert_(b: bool, err_msg: str): if not b: + logging.getLogger("debug") raise OpenStudioStandardsFormDataException(err_msg) diff --git a/data/openstudio_standards_data/database_tables/__init__.py b/data/openstudio_standards_data/database_tables/__init__.py index 7fc4530a41..971582bc74 100644 --- a/data/openstudio_standards_data/database_tables/__init__.py +++ b/data/openstudio_standards_data/database_tables/__init__.py @@ -49,8 +49,8 @@ "level_2_lighting_space_types", "level_2_ventilation_space_types", "level_1_space_types", - "envelope_requirement", "support_constructions", + "envelope_requirement", ] From c749002d0aa3288e35092cc6cad4c440a383e1f0 Mon Sep 17 00:00:00 2001 From: Weili Xu Date: Tue, 30 May 2023 16:24:25 -0700 Subject: [PATCH 28/45] update units in envelope requirement, lighting and the original json file --- .../database_files/envelope_requirement.json | 13599 ++++++++++++++++ .../level_2_natural_gas_equipment.json | 12 +- .../level_3_lighting_90_1_2004.json | 252 +- .../level_3_lighting_90_1_2007.json | 258 +- .../level_3_lighting_90_1_2010.json | 266 +- .../level_3_lighting_90_1_2013.json | 286 +- .../level_3_lighting_90_1_2016.json | 284 +- .../level_3_lighting_90_1_2019.json | 278 +- .../database_tables/envelope_requirement.py | 17 +- .../level_3_lighting_90_1_definition.py | 10 +- 10 files changed, 14438 insertions(+), 824 deletions(-) diff --git a/data/openstudio_standards_data/database_files/envelope_requirement.json b/data/openstudio_standards_data/database_files/envelope_requirement.json index 383b01982e..2ff3d3a28f 100644 --- a/data/openstudio_standards_data/database_files/envelope_requirement.json +++ b/data/openstudio_standards_data/database_files/envelope_requirement.json @@ -10,10 +10,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29,10 +32,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48,10 +54,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67,10 +76,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -86,10 +98,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -105,10 +120,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -124,10 +142,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -143,10 +164,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -162,10 +186,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -181,10 +208,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -200,10 +230,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -219,10 +252,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -238,10 +274,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -257,10 +296,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -276,10 +318,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -295,10 +340,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -314,10 +362,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -333,10 +384,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -352,10 +406,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.034, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -371,10 +428,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -390,10 +450,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -409,10 +472,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -428,10 +494,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.614, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -447,10 +516,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -466,10 +538,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.28, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -485,10 +560,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -504,10 +582,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -523,10 +604,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -542,10 +626,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -561,10 +648,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -580,10 +670,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -599,10 +692,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -618,10 +714,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -637,10 +736,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -656,10 +758,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -675,10 +780,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.18, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -694,10 +802,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.352, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -713,10 +824,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.292, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -732,10 +846,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -751,10 +868,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -770,10 +890,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -789,10 +912,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -808,10 +934,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -827,10 +956,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -846,10 +978,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -865,10 +1000,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -884,10 +1022,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -903,10 +1044,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -922,10 +1066,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -941,10 +1088,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -960,10 +1110,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -979,10 +1132,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -998,10 +1154,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1017,10 +1176,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1036,10 +1198,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1055,10 +1220,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1074,10 +1242,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1093,10 +1264,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1112,10 +1286,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1131,10 +1308,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1150,10 +1330,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1169,10 +1352,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1188,10 +1374,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1207,10 +1396,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1226,10 +1418,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1245,10 +1440,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1264,10 +1462,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1283,10 +1484,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1302,10 +1506,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1321,10 +1528,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1340,10 +1550,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1359,10 +1572,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1378,10 +1594,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1397,10 +1616,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1416,10 +1638,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1435,10 +1660,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1454,10 +1682,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1473,10 +1704,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1492,10 +1726,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1511,10 +1748,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1530,10 +1770,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1549,10 +1792,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1568,10 +1814,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1587,10 +1836,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.137, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1606,10 +1858,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1625,10 +1880,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1644,10 +1902,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.107, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1663,10 +1924,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1682,10 +1946,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1701,10 +1968,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1720,10 +1990,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1739,10 +2012,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1758,10 +2034,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1777,10 +2056,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1796,10 +2078,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1815,10 +2100,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.034, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1834,10 +2122,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1853,10 +2144,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1872,10 +2166,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.218, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1891,10 +2188,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.081, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1910,10 +2210,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1929,10 +2232,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.167, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1948,10 +2254,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1967,10 +2276,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -1986,10 +2298,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2005,10 +2320,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2024,10 +2342,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2043,10 +2364,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2062,10 +2386,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2081,10 +2408,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2100,10 +2430,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2119,10 +2452,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2138,10 +2474,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.184, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2157,10 +2496,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.352, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2176,10 +2518,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.292, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2195,10 +2540,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2214,10 +2562,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2233,10 +2584,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2252,10 +2606,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2271,10 +2628,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2290,10 +2650,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2309,10 +2672,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2328,10 +2694,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2347,10 +2716,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2366,10 +2738,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2385,10 +2760,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2404,10 +2782,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2423,10 +2804,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2442,10 +2826,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.17, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2461,10 +2848,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.17, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2480,10 +2870,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.17, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2499,10 +2892,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2518,10 +2914,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2537,10 +2936,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2556,10 +2958,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2575,10 +2980,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2594,10 +3002,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2613,10 +3024,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2632,10 +3046,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2651,10 +3068,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2670,10 +3090,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2689,10 +3112,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2708,10 +3134,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2727,10 +3156,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.17, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2746,10 +3178,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.17, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2765,10 +3200,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.17, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2784,10 +3222,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2803,10 +3244,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2822,10 +3266,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2841,10 +3288,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2860,10 +3310,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2879,10 +3332,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2898,10 +3354,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2917,10 +3376,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2936,10 +3398,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2955,10 +3420,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2974,10 +3442,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -2993,10 +3464,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3012,10 +3486,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3031,10 +3508,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3050,10 +3530,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3069,10 +3552,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3088,10 +3574,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3107,10 +3596,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3126,10 +3618,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3145,10 +3640,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.17, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3164,10 +3662,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3183,10 +3684,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3202,10 +3706,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3221,10 +3728,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3240,10 +3750,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.17, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3259,10 +3772,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3278,10 +3794,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3297,10 +3816,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3316,10 +3838,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3335,10 +3860,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3354,10 +3882,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3373,10 +3904,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3392,10 +3926,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3411,10 +3948,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3430,10 +3970,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3449,10 +3992,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3468,10 +4014,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3487,10 +4036,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3506,10 +4058,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3525,10 +4080,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3544,10 +4102,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3563,10 +4124,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3582,10 +4146,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3601,10 +4168,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3620,10 +4190,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3639,10 +4212,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3658,10 +4234,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3677,10 +4256,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3696,10 +4278,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3715,10 +4300,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3734,10 +4322,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3753,10 +4344,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3772,10 +4366,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3791,10 +4388,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3810,10 +4410,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3829,10 +4432,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3848,10 +4454,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3867,10 +4476,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3886,10 +4498,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3905,10 +4520,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3924,10 +4542,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3943,10 +4564,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3962,10 +4586,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -3981,10 +4608,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4000,10 +4630,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4019,10 +4652,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4038,10 +4674,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4057,10 +4696,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4076,10 +4718,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4095,10 +4740,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4114,10 +4762,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4133,10 +4784,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.107, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4152,10 +4806,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4171,10 +4828,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4190,10 +4850,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.087, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4209,10 +4872,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4228,10 +4894,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4247,10 +4916,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4266,10 +4938,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.069, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4285,10 +4960,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4304,10 +4982,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4323,10 +5004,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4342,10 +5026,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.034, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4361,10 +5048,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4380,10 +5070,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4399,10 +5092,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.218, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4418,10 +5114,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.081, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4437,10 +5136,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4456,10 +5158,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.097, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4475,10 +5180,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4494,10 +5202,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4513,10 +5224,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4532,10 +5246,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4551,10 +5268,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.123, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4570,10 +5290,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4589,10 +5312,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.084, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4608,10 +5334,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4627,10 +5356,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4646,10 +5378,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.184, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4665,10 +5400,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.352, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4684,10 +5422,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4703,10 +5444,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4722,10 +5466,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4741,10 +5488,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4760,10 +5510,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4779,10 +5532,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4798,10 +5554,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4817,10 +5576,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4836,10 +5598,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4855,10 +5620,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4874,10 +5642,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4893,10 +5664,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4912,10 +5686,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4931,10 +5708,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4950,10 +5730,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4969,10 +5752,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -4988,10 +5774,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5007,10 +5796,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5026,10 +5818,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5045,10 +5840,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5064,10 +5862,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5083,10 +5884,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5102,10 +5906,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5121,10 +5928,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5140,10 +5950,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5159,10 +5972,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5178,10 +5994,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5197,10 +6016,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5216,10 +6038,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5235,10 +6060,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5254,10 +6082,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5273,10 +6104,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5292,10 +6126,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5311,10 +6148,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5330,10 +6170,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5349,10 +6192,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5368,10 +6214,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5387,10 +6236,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5406,10 +6258,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5425,10 +6280,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5444,10 +6302,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5463,10 +6324,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5482,10 +6346,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5501,10 +6368,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5520,10 +6390,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5539,10 +6412,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5558,10 +6434,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5577,10 +6456,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5596,10 +6478,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5615,10 +6500,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5634,10 +6522,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5653,10 +6544,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5672,10 +6566,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5691,10 +6588,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5710,10 +6610,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5729,10 +6632,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5748,10 +6654,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5767,10 +6676,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5786,10 +6698,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5805,10 +6720,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5824,10 +6742,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5843,10 +6764,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5862,10 +6786,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5881,10 +6808,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5900,10 +6830,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5919,10 +6852,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5938,10 +6874,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5957,10 +6896,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5976,10 +6918,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -5995,10 +6940,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6014,10 +6962,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.17, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6033,10 +6984,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.17, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6052,10 +7006,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.34, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6071,10 +7028,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.3, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.27, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6090,10 +7050,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.3, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.27, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6109,10 +7072,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6128,10 +7094,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.69, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6147,10 +7116,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.69, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6166,10 +7138,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6185,10 +7160,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6204,10 +7182,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6223,10 +7204,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6242,10 +7226,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6261,10 +7248,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6280,10 +7270,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6299,10 +7292,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.107, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6318,10 +7314,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6337,10 +7336,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6356,10 +7358,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.087, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6375,10 +7380,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6394,10 +7402,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6413,10 +7424,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6432,10 +7446,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.069, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6451,10 +7468,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6470,10 +7490,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6489,10 +7512,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6508,10 +7534,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6527,10 +7556,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.218, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6546,10 +7578,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.081, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6565,10 +7600,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6584,10 +7622,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.097, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6603,10 +7644,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6622,10 +7666,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6641,10 +7688,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6660,10 +7710,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6679,10 +7732,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.123, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6698,10 +7754,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6717,10 +7776,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.084, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6736,10 +7798,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6755,10 +7820,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6774,10 +7842,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.184, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6793,10 +7864,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.352, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6812,10 +7886,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6831,10 +7908,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6850,10 +7930,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6869,10 +7952,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6888,10 +7974,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6907,10 +7996,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6926,10 +8018,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6945,10 +8040,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6964,10 +8062,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -6983,10 +8084,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7002,10 +8106,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7021,10 +8128,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7040,10 +8150,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7059,10 +8172,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7078,10 +8194,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7097,10 +8216,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7116,10 +8238,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7135,10 +8260,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7154,10 +8282,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7173,10 +8304,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7192,10 +8326,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7211,10 +8348,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7230,10 +8370,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7249,10 +8392,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7268,10 +8414,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7287,10 +8436,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7306,10 +8458,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7325,10 +8480,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7344,10 +8502,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7363,10 +8524,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7382,10 +8546,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7401,10 +8568,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7420,10 +8590,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7439,10 +8612,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7458,10 +8634,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7477,10 +8656,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7496,10 +8678,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7515,10 +8700,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7534,10 +8722,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7553,10 +8744,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7572,10 +8766,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7591,10 +8788,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7610,10 +8810,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7629,10 +8832,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7648,10 +8854,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7667,10 +8876,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7686,10 +8898,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7705,10 +8920,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7724,10 +8942,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7743,10 +8964,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7762,10 +8986,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7781,10 +9008,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7800,10 +9030,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7819,10 +9052,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7838,10 +9074,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7857,10 +9096,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7876,10 +9118,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7895,10 +9140,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7914,10 +9162,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7933,10 +9184,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7952,10 +9206,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7971,10 +9228,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -7990,10 +9250,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.034, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8009,10 +9272,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8028,10 +9294,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8047,10 +9316,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8066,10 +9338,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8085,10 +9360,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8104,10 +9382,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8123,10 +9404,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8142,10 +9426,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8161,10 +9448,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8180,10 +9470,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.17, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8199,10 +9492,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.17, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8218,10 +9514,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8237,10 +9536,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.3, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8256,10 +9558,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.3, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8275,10 +9580,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8294,10 +9602,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.69, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8313,10 +9624,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.69, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8332,10 +9646,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.65, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8351,10 +9668,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8370,10 +9690,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8389,10 +9712,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8408,10 +9734,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8427,10 +9756,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8446,10 +9778,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8465,10 +9800,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.107, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8484,10 +9822,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8503,10 +9844,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8522,10 +9866,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.087, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8541,10 +9888,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8560,10 +9910,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8579,10 +9932,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8598,10 +9954,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.069, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8617,10 +9976,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8636,10 +9998,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8655,10 +10020,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8674,10 +10042,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8693,10 +10064,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.218, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8712,10 +10086,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.081, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8731,10 +10108,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8750,10 +10130,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.097, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8769,10 +10152,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8788,10 +10174,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8807,10 +10196,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8826,10 +10218,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8845,10 +10240,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.123, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8864,10 +10262,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8883,10 +10284,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.084, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8902,10 +10306,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8921,10 +10328,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8940,10 +10350,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.184, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8959,10 +10372,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.352, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8978,10 +10394,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -8997,10 +10416,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.61, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9016,10 +10438,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.61, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9035,10 +10460,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.61, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9054,10 +10482,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9073,10 +10504,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9092,10 +10526,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9111,10 +10548,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9130,10 +10570,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9149,10 +10592,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9168,10 +10614,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.34, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9187,10 +10636,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.34, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9206,10 +10658,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.34, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9225,10 +10680,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9244,10 +10702,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9263,10 +10724,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9282,10 +10746,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.61, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9301,10 +10768,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.61, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9320,10 +10790,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.61, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9339,10 +10812,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.61, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9358,10 +10834,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.61, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9377,10 +10856,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.61, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9396,10 +10878,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9415,10 +10900,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9434,10 +10922,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9453,10 +10944,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.34, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9472,10 +10966,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.34, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9491,10 +10988,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.34, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9510,10 +11010,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.72, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9529,10 +11032,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.72, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9548,10 +11054,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.72, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9567,10 +11076,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9586,10 +11098,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9605,10 +11120,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9624,10 +11142,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9643,10 +11164,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9662,10 +11186,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9681,10 +11208,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9700,10 +11230,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9719,10 +11252,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9738,10 +11274,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9757,10 +11296,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9776,10 +11318,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9795,10 +11340,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9814,10 +11362,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9833,10 +11384,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9852,10 +11406,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.61, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9871,10 +11428,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9890,10 +11450,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9909,10 +11472,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.34, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9928,10 +11494,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9947,10 +11516,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.61, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9966,10 +11538,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.61, "assembly_minimum_vt_shgc": null, "annotation": null @@ -9985,10 +11560,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10004,10 +11582,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.34, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10023,10 +11604,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.72, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10042,10 +11626,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10061,10 +11648,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10080,10 +11670,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10099,10 +11692,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10118,10 +11714,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10137,10 +11736,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10156,10 +11758,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.034, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10175,10 +11780,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10194,10 +11802,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10213,10 +11824,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10232,10 +11846,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10251,10 +11868,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10270,10 +11890,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10289,10 +11912,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10308,10 +11934,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10327,10 +11956,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10346,10 +11978,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.27, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10365,10 +12000,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.27, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10384,10 +12022,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10403,10 +12044,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10422,10 +12066,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10441,10 +12088,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10460,10 +12110,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10479,10 +12132,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10498,10 +12154,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10517,10 +12176,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10536,10 +12198,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10555,10 +12220,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10574,10 +12242,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10593,10 +12264,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10612,10 +12286,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10631,10 +12308,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.107, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10650,10 +12330,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10669,10 +12352,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10688,10 +12374,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.087, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10707,10 +12396,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10726,10 +12418,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10745,10 +12440,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10764,10 +12462,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.069, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10783,10 +12484,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.066, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10802,10 +12506,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10821,10 +12528,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10840,10 +12550,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10859,10 +12572,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.034, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10878,10 +12594,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10897,10 +12616,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10916,10 +12638,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.218, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10935,10 +12660,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.081, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10954,10 +12682,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10973,10 +12704,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.097, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -10992,10 +12726,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11011,10 +12748,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11030,10 +12770,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11049,10 +12792,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11068,10 +12814,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11087,10 +12836,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.104, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11106,10 +12858,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11125,10 +12880,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11144,10 +12902,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11163,10 +12924,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11182,10 +12946,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.134, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11201,10 +12968,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11220,10 +12990,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11239,10 +13012,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11258,10 +13034,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11277,10 +13056,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11296,10 +13078,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11315,10 +13100,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11334,10 +13122,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11353,10 +13144,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11372,10 +13166,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11391,10 +13188,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11410,10 +13210,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11429,10 +13232,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11448,10 +13254,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11467,10 +13276,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11486,10 +13298,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11505,10 +13320,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11524,10 +13342,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11543,10 +13364,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11562,10 +13386,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11581,10 +13408,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11600,10 +13430,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11619,10 +13452,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11638,10 +13474,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11657,10 +13496,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11676,10 +13518,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11695,10 +13540,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11714,10 +13562,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11733,10 +13584,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11752,10 +13606,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11771,10 +13628,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11790,10 +13650,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11809,10 +13672,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11828,10 +13694,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11847,10 +13716,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11866,10 +13738,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11885,10 +13760,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11904,10 +13782,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11923,10 +13804,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11942,10 +13826,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11961,10 +13848,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11980,10 +13870,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -11999,10 +13892,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12018,10 +13914,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12037,10 +13936,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12056,10 +13958,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12075,10 +13980,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12094,10 +14002,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12113,10 +14024,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12132,10 +14046,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12151,10 +14068,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12170,10 +14090,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12189,10 +14112,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12208,10 +14134,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12227,10 +14156,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12246,10 +14178,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12265,10 +14200,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12284,10 +14222,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12303,10 +14244,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12322,10 +14266,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12341,10 +14288,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12360,10 +14310,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12379,10 +14332,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12398,10 +14354,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12417,10 +14376,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.95, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12436,10 +14398,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12455,10 +14420,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.84, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12474,10 +14442,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12493,10 +14464,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12512,10 +14486,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12531,10 +14508,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12550,10 +14530,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12569,10 +14552,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12588,10 +14574,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.17, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12607,10 +14596,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12626,10 +14618,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12645,10 +14640,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.3, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12664,10 +14662,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.3, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12683,10 +14684,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.65, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12702,10 +14706,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.69, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.27, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12721,10 +14728,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.27, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12740,10 +14750,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12759,10 +14772,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12778,10 +14794,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12797,10 +14816,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12816,10 +14838,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12835,10 +14860,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12854,10 +14882,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12873,10 +14904,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.087, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12892,10 +14926,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12911,10 +14948,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12930,10 +14970,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.074, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12949,10 +14992,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12968,10 +15014,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -12987,10 +15036,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13006,10 +15058,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.069, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13025,10 +15080,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.066, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13044,10 +15102,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13063,10 +15124,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13082,10 +15146,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13101,10 +15168,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13120,10 +15190,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.034, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13139,10 +15212,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13158,10 +15234,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13177,10 +15256,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.173, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13196,10 +15278,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.053, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13215,10 +15300,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.097, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13234,10 +15322,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13253,10 +15344,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.123, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13272,10 +15366,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13291,10 +15388,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.084, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13310,10 +15410,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13329,10 +15432,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.09, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13348,10 +15454,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.057, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13367,10 +15476,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13386,10 +15498,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13405,10 +15520,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13424,10 +15542,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.123, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13443,10 +15564,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13462,10 +15586,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13481,10 +15608,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13500,10 +15630,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13519,10 +15652,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13538,10 +15674,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13557,10 +15696,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13576,10 +15718,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13595,10 +15740,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13614,10 +15762,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13633,10 +15784,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13652,10 +15806,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13671,10 +15828,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13690,10 +15850,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13709,10 +15872,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13728,10 +15894,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.26, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13747,10 +15916,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.26, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13766,10 +15938,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.26, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13785,10 +15960,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13804,10 +15982,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13823,10 +16004,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13842,10 +16026,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13861,10 +16048,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13880,10 +16070,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13899,10 +16092,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13918,10 +16114,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13937,10 +16136,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13956,10 +16158,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13975,10 +16180,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -13994,10 +16202,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14013,10 +16224,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.26, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14032,10 +16246,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.26, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14051,10 +16268,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.26, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14070,10 +16290,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14089,10 +16312,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14108,10 +16334,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14127,10 +16356,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14146,10 +16378,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14165,10 +16400,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14184,10 +16422,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14203,10 +16444,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14222,10 +16466,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14241,10 +16488,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14260,10 +16510,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14279,10 +16532,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14298,10 +16554,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14317,10 +16576,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14336,10 +16598,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14355,10 +16620,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14374,10 +16642,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14393,10 +16664,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14412,10 +16686,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14431,10 +16708,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.26, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14450,10 +16730,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14469,10 +16752,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14488,10 +16774,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14507,10 +16796,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14526,10 +16818,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.26, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14545,10 +16840,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14564,10 +16862,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14583,10 +16884,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14602,10 +16906,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14621,10 +16928,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14640,10 +16950,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14659,10 +16972,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.84, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14678,10 +16994,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14697,10 +17016,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.84, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14716,10 +17038,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14735,10 +17060,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14754,10 +17082,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14773,10 +17104,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14792,10 +17126,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14811,10 +17148,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14830,10 +17170,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.17, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14849,10 +17192,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.17, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14868,10 +17214,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14887,10 +17236,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.1, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14906,10 +17258,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.1, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14925,10 +17280,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14944,10 +17302,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.69, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.61, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14963,10 +17324,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.69, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -14982,10 +17346,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15001,10 +17368,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15020,10 +17390,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15039,10 +17412,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15058,10 +17434,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15077,10 +17456,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15096,10 +17478,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15115,10 +17500,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.087, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15134,10 +17522,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15153,10 +17544,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15172,10 +17566,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15191,10 +17588,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15210,10 +17610,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15229,10 +17632,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15248,10 +17654,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.069, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15267,10 +17676,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.0066, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15286,10 +17698,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15305,10 +17720,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15324,10 +17742,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15343,10 +17764,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15362,10 +17786,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15381,10 +17808,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15400,10 +17830,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15419,10 +17852,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.173, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15438,10 +17874,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.053, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15457,10 +17896,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.097, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15476,10 +17918,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15495,10 +17940,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.104, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15514,10 +17962,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15533,10 +17984,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.084, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15552,10 +18006,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15571,10 +18028,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.09, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15590,10 +18050,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.057, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15609,10 +18072,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15628,10 +18094,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15647,10 +18116,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15666,10 +18138,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15685,10 +18160,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15704,10 +18182,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15723,10 +18204,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15742,10 +18226,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15761,10 +18248,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15780,10 +18270,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15799,10 +18292,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15818,10 +18314,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15837,10 +18336,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15856,10 +18358,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15875,10 +18380,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15894,10 +18402,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15913,10 +18424,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15932,10 +18446,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15951,10 +18468,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15970,10 +18490,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.26, "assembly_minimum_vt_shgc": null, "annotation": null @@ -15989,10 +18512,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.26, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16008,10 +18534,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.26, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16027,10 +18556,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16046,10 +18578,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16065,10 +18600,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16084,10 +18622,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16103,10 +18644,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16122,10 +18666,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16141,10 +18688,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16160,10 +18710,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16179,10 +18732,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16198,10 +18754,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16217,10 +18776,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16236,10 +18798,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16255,10 +18820,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.26, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16274,10 +18842,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.26, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16293,10 +18864,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.26, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16312,10 +18886,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16331,10 +18908,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16350,10 +18930,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16369,10 +18952,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16388,10 +18974,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16407,10 +18996,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16426,10 +19018,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16445,10 +19040,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16464,10 +19062,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16483,10 +19084,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16502,10 +19106,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16521,10 +19128,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16540,10 +19150,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16559,10 +19172,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16578,10 +19194,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16597,10 +19216,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16616,10 +19238,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16635,10 +19260,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16654,10 +19282,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16673,10 +19304,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.26, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16692,10 +19326,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16711,10 +19348,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16730,10 +19370,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16749,10 +19392,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16768,10 +19414,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.26, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16787,10 +19436,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16806,10 +19458,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16825,10 +19480,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16844,10 +19502,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16863,10 +19524,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16882,10 +19546,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16901,10 +19568,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.84, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16920,10 +19590,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16939,10 +19612,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.78, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16958,10 +19634,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16977,10 +19656,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -16996,10 +19678,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17015,10 +19700,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17034,10 +19722,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17053,10 +19744,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17072,10 +19766,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.17, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17091,10 +19788,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17110,10 +19810,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.65, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17129,10 +19832,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.87, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.65, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17148,10 +19854,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.74, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.34, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17167,10 +19876,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17186,10 +19898,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.69, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17205,10 +19920,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.61, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17224,10 +19942,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17243,10 +19964,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17262,10 +19986,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17281,10 +20008,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17300,10 +20030,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17319,10 +20052,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17338,10 +20074,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17357,10 +20096,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.087, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17376,10 +20118,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17395,10 +20140,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17414,10 +20162,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17433,10 +20184,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17452,10 +20206,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17471,10 +20228,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.137, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17490,10 +20250,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17509,10 +20272,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.066, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17528,10 +20294,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17547,10 +20316,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17566,10 +20338,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17585,10 +20360,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17604,10 +20382,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17623,10 +20404,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17642,10 +20426,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17661,10 +20448,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.173, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17680,10 +20470,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.053, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17699,10 +20492,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.097, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17718,10 +20514,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17737,10 +20536,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.09, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17756,10 +20558,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.057, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17775,10 +20580,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17794,10 +20602,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17813,10 +20624,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.08, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17832,10 +20646,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.057, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17851,10 +20668,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17870,10 +20690,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17889,10 +20712,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17908,10 +20734,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17927,10 +20756,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17946,10 +20778,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17965,10 +20800,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -17984,10 +20822,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18003,10 +20844,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18022,10 +20866,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18041,10 +20888,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18060,10 +20910,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18079,10 +20932,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18098,10 +20954,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18117,10 +20976,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18136,10 +20998,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18155,10 +21020,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18174,10 +21042,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18193,10 +21064,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18212,10 +21086,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18231,10 +21108,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18250,10 +21130,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18269,10 +21152,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18288,10 +21174,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18307,10 +21196,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18326,10 +21218,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18345,10 +21240,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18364,10 +21262,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18383,10 +21284,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18402,10 +21306,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18421,10 +21328,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18440,10 +21350,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18459,10 +21372,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18478,10 +21394,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18497,10 +21416,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18516,10 +21438,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18535,10 +21460,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18554,10 +21482,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18573,10 +21504,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18592,10 +21526,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18611,10 +21548,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18630,10 +21570,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18649,10 +21592,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18668,10 +21614,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18687,10 +21636,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18706,10 +21658,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18725,10 +21680,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18744,10 +21702,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18763,10 +21724,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18782,10 +21746,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18801,10 +21768,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18820,10 +21790,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18839,10 +21812,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18858,10 +21834,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18877,10 +21856,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18896,10 +21878,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18915,10 +21900,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18934,10 +21922,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18953,10 +21944,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18972,10 +21966,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -18991,10 +21988,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19010,10 +22010,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19029,10 +22032,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19048,10 +22054,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19067,10 +22076,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19086,10 +22098,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19105,10 +22120,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19124,10 +22142,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19143,10 +22164,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.84, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19162,10 +22186,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.54, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19181,10 +22208,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.78, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19200,10 +22230,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19219,10 +22252,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19238,10 +22274,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19257,10 +22296,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19276,10 +22318,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19295,10 +22340,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19314,10 +22362,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.17, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19333,10 +22384,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.17, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19352,10 +22406,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19371,10 +22428,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.87, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19390,10 +22450,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.61, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19409,10 +22472,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19428,10 +22494,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.69, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19447,10 +22516,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.69, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19466,10 +22538,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.65, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19485,10 +22560,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19504,10 +22582,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19523,10 +22604,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19542,10 +22626,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19561,10 +22648,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19580,10 +22670,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19599,10 +22692,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19618,10 +22714,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19637,10 +22736,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19656,10 +22758,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.057, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19675,10 +22780,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19694,10 +22802,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19713,10 +22824,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.137, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19732,10 +22846,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19751,10 +22868,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19770,10 +22890,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19789,10 +22912,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.049, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19808,10 +22934,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.049, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19827,10 +22956,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19846,10 +22978,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19865,10 +23000,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19884,10 +23022,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19903,10 +23044,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.093, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19922,10 +23066,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.034, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19941,10 +23088,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.072, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19960,10 +23110,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19979,10 +23132,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.08, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -19998,10 +23154,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.057, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20017,10 +23176,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20036,10 +23198,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20055,10 +23220,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.071, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20074,10 +23242,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.057, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20093,10 +23264,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.055, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20112,10 +23286,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20131,10 +23308,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20150,10 +23330,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20169,10 +23352,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20188,10 +23374,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20207,10 +23396,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20226,10 +23418,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20245,10 +23440,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20264,10 +23462,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20283,10 +23484,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20302,10 +23506,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20321,10 +23528,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20340,10 +23550,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20359,10 +23572,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20378,10 +23594,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20397,10 +23616,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20416,10 +23638,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20435,10 +23660,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20454,10 +23682,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20473,10 +23704,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20492,10 +23726,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20511,10 +23748,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20530,10 +23770,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20549,10 +23792,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20568,10 +23814,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20587,10 +23836,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20606,10 +23858,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20625,10 +23880,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20644,10 +23902,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20663,10 +23924,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20682,10 +23946,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20701,10 +23968,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20720,10 +23990,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20739,10 +24012,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20758,10 +24034,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20777,10 +24056,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20796,10 +24078,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20815,10 +24100,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20834,10 +24122,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20853,10 +24144,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20872,10 +24166,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20891,10 +24188,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20910,10 +24210,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20929,10 +24232,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20948,10 +24254,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20967,10 +24276,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -20986,10 +24298,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21005,10 +24320,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21024,10 +24342,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21043,10 +24364,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21062,10 +24386,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21081,10 +24408,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21100,10 +24430,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21119,10 +24452,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21138,10 +24474,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21157,10 +24496,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21176,10 +24518,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21195,10 +24540,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21214,10 +24562,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21233,10 +24584,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 0.46, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21252,10 +24606,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21271,10 +24628,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21290,10 +24650,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21309,10 +24672,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21328,10 +24694,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21347,10 +24716,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21366,10 +24738,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.54, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21385,10 +24760,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.78, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21404,10 +24782,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.52, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21423,10 +24804,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.78, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21442,10 +24826,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21461,10 +24848,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.95, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21480,10 +24870,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21499,10 +24892,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21518,10 +24914,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21537,10 +24936,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21556,10 +24958,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.62, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21575,10 +24980,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.27, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21594,10 +25002,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.3, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21613,10 +25024,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.61, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21632,10 +25046,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.61, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21651,10 +25068,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.1, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21670,10 +25090,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21689,10 +25112,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21708,10 +25134,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.81, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21727,10 +25156,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21746,10 +25178,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21765,10 +25200,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21784,10 +25222,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21803,10 +25244,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21822,10 +25266,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21841,10 +25288,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21860,10 +25310,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21879,10 +25332,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21898,10 +25354,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21917,10 +25376,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21936,10 +25398,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21955,10 +25420,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21974,10 +25442,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -21993,10 +25464,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22012,10 +25486,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22031,10 +25508,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22050,10 +25530,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22069,10 +25552,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22088,10 +25574,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22107,10 +25596,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22126,10 +25618,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22145,10 +25640,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22164,10 +25662,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22183,10 +25684,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22202,10 +25706,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22221,10 +25728,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22240,10 +25750,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22259,10 +25772,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22278,10 +25794,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22297,10 +25816,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22316,10 +25838,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22335,10 +25860,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22354,10 +25882,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22373,10 +25904,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.16, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22392,10 +25926,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22411,10 +25948,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22430,10 +25970,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.34, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22449,10 +25992,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.27, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22468,10 +26014,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.27, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22487,10 +26036,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22506,10 +26058,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22525,10 +26080,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22544,10 +26102,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22563,10 +26124,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22582,10 +26146,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22601,10 +26168,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22620,10 +26190,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22639,10 +26212,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22658,10 +26234,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22677,10 +26256,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22696,10 +26278,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22715,10 +26300,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22734,10 +26322,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22753,10 +26344,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22772,10 +26366,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22791,10 +26388,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22810,10 +26410,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22829,10 +26432,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22848,10 +26454,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.034, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22867,10 +26476,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22886,10 +26498,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22905,10 +26520,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.218, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22924,10 +26542,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.081, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22943,10 +26564,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22962,10 +26586,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.28, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -22981,10 +26608,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23000,10 +26630,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23019,10 +26652,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23038,10 +26674,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23057,10 +26696,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23076,10 +26718,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23095,10 +26740,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23114,10 +26762,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23133,10 +26784,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23152,10 +26806,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23171,10 +26828,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.107, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23190,10 +26850,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23209,10 +26872,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23228,10 +26894,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.087, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23247,10 +26916,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23266,10 +26938,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23285,10 +26960,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23304,10 +26982,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.069, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23323,10 +27004,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.066, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23342,10 +27026,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23361,10 +27048,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23380,10 +27070,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23399,10 +27092,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23418,10 +27114,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23437,10 +27136,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23456,10 +27158,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.218, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23475,10 +27180,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.081, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23494,10 +27202,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23513,10 +27224,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.167, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23532,10 +27246,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23551,10 +27268,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23570,10 +27290,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23589,10 +27312,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23608,10 +27334,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23627,10 +27356,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.123, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23646,10 +27378,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23665,10 +27400,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23684,10 +27422,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23703,10 +27444,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23722,10 +27466,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.184, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23741,10 +27488,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23760,10 +27510,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23779,10 +27532,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23798,10 +27554,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23817,10 +27576,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23836,10 +27598,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23855,10 +27620,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23874,10 +27642,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23893,10 +27664,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23912,10 +27686,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23931,10 +27708,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23950,10 +27730,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23969,10 +27752,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.1, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -23988,10 +27774,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.1, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24007,10 +27796,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24026,10 +27818,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24045,10 +27840,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24064,10 +27862,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24083,10 +27884,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24102,10 +27906,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24121,10 +27928,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24140,10 +27950,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24159,10 +27972,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24178,10 +27994,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24197,10 +28016,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24216,10 +28038,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24235,10 +28060,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24254,10 +28082,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24273,10 +28104,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24292,10 +28126,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24311,10 +28148,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24330,10 +28170,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24349,10 +28192,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.46, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24368,10 +28214,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24387,10 +28236,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24406,10 +28258,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24425,10 +28280,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24444,10 +28302,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24463,10 +28324,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24482,10 +28346,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24501,10 +28368,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.107, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24520,10 +28390,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24539,10 +28412,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24558,10 +28434,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.087, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24577,10 +28456,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24596,10 +28478,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24615,10 +28500,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24634,10 +28522,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.069, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24653,10 +28544,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.066, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24672,10 +28566,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24691,10 +28588,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24710,10 +28610,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24729,10 +28632,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24748,10 +28654,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24767,10 +28676,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24786,10 +28698,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.173, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24805,10 +28720,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.053, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24824,10 +28742,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.055, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24843,10 +28764,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.097, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24862,10 +28786,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24881,10 +28808,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.123, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24900,10 +28830,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24919,10 +28852,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.084, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24938,10 +28874,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24957,10 +28896,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.104, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24976,10 +28918,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.084, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -24995,10 +28940,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25014,10 +28962,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25033,10 +28984,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25052,10 +29006,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.184, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25071,10 +29028,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25090,10 +29050,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25109,10 +29072,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25128,10 +29094,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25147,10 +29116,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.6, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25166,10 +29138,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25185,10 +29160,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25204,10 +29182,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.6, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25223,10 +29204,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25242,10 +29226,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25261,10 +29248,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25280,10 +29270,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25299,10 +29292,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25318,10 +29314,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25337,10 +29336,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25356,10 +29358,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25375,10 +29380,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.9, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25394,10 +29402,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25413,10 +29424,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.09, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25432,10 +29446,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25451,10 +29468,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25470,10 +29490,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25489,10 +29512,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25508,10 +29534,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25527,10 +29556,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25546,10 +29578,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.17, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25565,10 +29600,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.17, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25584,10 +29622,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.71, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25603,10 +29644,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.3, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.65, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25622,10 +29666,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.3, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.55, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25641,10 +29688,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25660,10 +29710,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.69, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25679,10 +29732,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.69, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25698,10 +29754,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25717,10 +29776,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25736,10 +29798,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25755,10 +29820,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25774,10 +29842,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25793,10 +29864,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25812,10 +29886,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25831,10 +29908,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.087, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25850,10 +29930,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25869,10 +29952,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25888,10 +29974,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.074, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25907,10 +29996,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25926,10 +30018,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25945,10 +30040,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.137, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25964,10 +30062,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.069, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -25983,10 +30084,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.066, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26002,10 +30106,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26021,10 +30128,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26040,10 +30150,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26059,10 +30172,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26078,10 +30194,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26097,10 +30216,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26116,10 +30238,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26135,10 +30260,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.173, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26154,10 +30282,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.053, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26173,10 +30304,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.097, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26192,10 +30326,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26211,10 +30348,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.104, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26230,10 +30370,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26249,10 +30392,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26268,10 +30414,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26287,10 +30436,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.09, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26306,10 +30458,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26325,10 +30480,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26344,10 +30502,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26363,10 +30524,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26382,10 +30546,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.134, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26401,10 +30568,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26420,10 +30590,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26439,10 +30612,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26458,10 +30634,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.4, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26477,10 +30656,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26496,10 +30678,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26515,10 +30700,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.4, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26534,10 +30722,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26553,10 +30744,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26572,10 +30766,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26591,10 +30788,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26610,10 +30810,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26629,10 +30832,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.85, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26648,10 +30854,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.85, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26667,10 +30876,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26686,10 +30898,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26705,10 +30920,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.86, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26724,10 +30942,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.54, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26743,10 +30964,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.86, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26762,10 +30986,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26781,10 +31008,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26800,10 +31030,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26819,10 +31052,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26838,10 +31074,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26857,10 +31096,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26876,10 +31118,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.17, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26895,10 +31140,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26914,10 +31162,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26933,10 +31184,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.3, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.68, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26952,10 +31206,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.3, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.64, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26971,10 +31228,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.64, "assembly_minimum_vt_shgc": null, "annotation": null @@ -26990,10 +31250,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.69, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27009,10 +31272,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27028,10 +31294,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.77, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27047,10 +31316,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27066,10 +31338,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27085,10 +31360,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27104,10 +31382,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27123,10 +31404,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27142,10 +31426,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27161,10 +31448,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.074, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27180,10 +31470,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27199,10 +31492,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27218,10 +31514,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27237,10 +31536,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27256,10 +31558,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27275,10 +31580,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.137, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27294,10 +31602,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27313,10 +31624,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27332,10 +31646,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27351,10 +31668,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27370,10 +31690,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27389,10 +31712,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27408,10 +31734,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27427,10 +31756,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27446,10 +31778,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27465,10 +31800,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.119, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27484,10 +31822,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.053, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27503,10 +31844,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.097, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27522,10 +31866,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27541,10 +31888,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.09, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27560,10 +31910,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27579,10 +31932,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27598,10 +31954,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27617,10 +31976,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.08, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27636,10 +31998,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.057, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27655,10 +32020,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27674,10 +32042,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27693,10 +32064,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27712,10 +32086,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.123, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27731,10 +32108,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27750,10 +32130,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27769,10 +32152,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27788,10 +32174,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27807,10 +32196,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27826,10 +32218,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27845,10 +32240,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27864,10 +32262,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27883,10 +32284,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27902,10 +32306,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27921,10 +32328,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27940,10 +32350,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27959,10 +32372,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27978,10 +32394,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -27997,10 +32416,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28016,10 +32438,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28035,10 +32460,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.86, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28054,10 +32482,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.54, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28073,10 +32504,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.86, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28092,10 +32526,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28111,10 +32548,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28130,10 +32570,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28149,10 +32592,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28168,10 +32614,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28187,10 +32636,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28206,10 +32658,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.17, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.77, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28225,10 +32680,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.17, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.77, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28244,10 +32702,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28263,10 +32724,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.1, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28282,10 +32746,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.1, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.68, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28301,10 +32768,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.64, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28320,10 +32790,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.69, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.64, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28339,10 +32812,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.69, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28358,10 +32834,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28377,10 +32856,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28396,10 +32878,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28415,10 +32900,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28434,10 +32922,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28453,10 +32944,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28472,10 +32966,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28491,10 +32988,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28510,10 +33010,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28529,10 +33032,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28548,10 +33054,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.057, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28567,10 +33076,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28586,10 +33098,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28605,10 +33120,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.137, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28624,10 +33142,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28643,10 +33164,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28662,10 +33186,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28681,10 +33208,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28700,10 +33230,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28719,10 +33252,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28738,10 +33274,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28757,10 +33296,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28776,10 +33318,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28795,10 +33340,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.093, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28814,10 +33362,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.034, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28833,10 +33384,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.097, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28852,10 +33406,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28871,10 +33428,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.08, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28890,10 +33450,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28909,10 +33472,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28928,10 +33494,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28947,10 +33516,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.071, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28966,10 +33538,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.057, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -28985,10 +33560,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29004,10 +33582,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29023,10 +33604,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29042,10 +33626,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29061,10 +33648,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29080,10 +33670,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29099,10 +33692,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29118,10 +33714,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29137,10 +33736,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29156,10 +33758,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29175,10 +33780,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29194,10 +33802,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29213,10 +33824,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29232,10 +33846,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29251,10 +33868,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.6, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29270,10 +33890,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29289,10 +33912,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29308,10 +33934,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29327,10 +33956,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29346,10 +33978,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.54, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29365,10 +34000,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.86, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29384,10 +34022,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.52, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29403,10 +34044,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.688, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29422,10 +34066,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29441,10 +34088,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29460,10 +34110,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29479,10 +34132,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29498,10 +34154,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29517,10 +34176,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29536,10 +34198,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.17, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29555,10 +34220,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29574,10 +34242,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29593,10 +34264,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.87, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29612,10 +34286,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.74, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29631,10 +34308,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29650,10 +34330,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.69, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29669,10 +34352,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29688,10 +34374,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29707,10 +34396,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29726,10 +34418,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29745,10 +34440,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29764,10 +34462,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29783,10 +34484,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29802,10 +34506,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29821,10 +34528,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29840,10 +34550,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29859,10 +34572,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29878,10 +34594,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29897,10 +34616,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29916,10 +34638,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29935,10 +34660,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.107, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29954,10 +34682,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29973,10 +34704,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -29992,10 +34726,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30011,10 +34748,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30030,10 +34770,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30049,10 +34792,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30068,10 +34814,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30087,10 +34836,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30106,10 +34858,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30125,10 +34880,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.093, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30144,10 +34902,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.034, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30163,10 +34924,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.097, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30182,10 +34946,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30201,10 +34968,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.071, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30220,10 +34990,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.057, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30239,10 +35012,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30258,10 +35034,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30277,10 +35056,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.071, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30296,10 +35078,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.057, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30315,10 +35100,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.042, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30334,10 +35122,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30353,10 +35144,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.123, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30372,10 +35166,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30391,10 +35188,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30410,10 +35210,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30429,10 +35232,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30448,10 +35254,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30467,10 +35276,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.4, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30486,10 +35298,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30505,10 +35320,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30524,10 +35342,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.4, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30543,10 +35364,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30562,10 +35386,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30581,10 +35408,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.6, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30600,10 +35430,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30619,10 +35452,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30638,10 +35474,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30657,10 +35496,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30676,10 +35518,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.52, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30695,10 +35540,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.843, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30714,10 +35562,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.52, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30733,10 +35584,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.688, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30752,10 +35606,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30771,10 +35628,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.9, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30790,10 +35650,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30809,10 +35672,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30828,10 +35694,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.092, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30847,10 +35716,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30866,10 +35738,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.17, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30885,10 +35760,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.17, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30904,10 +35782,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30923,10 +35804,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.87, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30942,10 +35826,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.61, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30961,10 +35848,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30980,10 +35870,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.69, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -30999,10 +35892,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.69, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31018,10 +35914,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.16, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31037,10 +35936,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31056,10 +35958,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31075,10 +35980,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31094,10 +36002,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31113,10 +36024,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31132,10 +36046,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31151,10 +36068,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.057, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31170,10 +36090,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31189,10 +36112,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31208,10 +36134,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31227,10 +36156,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31246,10 +36178,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31265,10 +36200,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.087, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31284,10 +36222,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31303,10 +36244,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31322,10 +36266,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31341,10 +36288,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.049, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31360,10 +36310,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.049, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31379,10 +36332,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31398,10 +36354,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.021, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31417,10 +36376,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31436,10 +36398,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.021, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31455,10 +36420,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31474,10 +36442,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.034, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31493,10 +36464,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.072, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31512,10 +36486,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31531,10 +36508,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.071, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31550,10 +36530,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.057, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31569,10 +36552,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31588,10 +36574,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.036, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31607,10 +36596,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31626,10 +36618,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.057, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31645,10 +36640,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.037, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31664,10 +36662,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.036, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31683,10 +36684,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.104, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31702,10 +36706,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31721,10 +36728,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.084, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31740,10 +36750,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31759,10 +36772,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31778,10 +36794,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31797,10 +36816,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.4, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31816,10 +36838,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31835,10 +36860,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31854,10 +36882,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.4, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31873,10 +36904,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31892,10 +36926,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31911,10 +36948,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.6, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31930,10 +36970,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31949,10 +36992,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31968,10 +37014,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -31987,10 +37036,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32006,10 +37058,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.52, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32025,10 +37080,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.688, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32044,10 +37102,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.51, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32063,10 +37124,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.688, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32082,10 +37146,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32101,10 +37168,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.9, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32120,10 +37190,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32139,10 +37212,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32158,10 +37234,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.075, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32177,10 +37256,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32196,10 +37278,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32215,10 +37300,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32234,10 +37322,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.3, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.34, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32253,10 +37344,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.61, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.27, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32272,10 +37366,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.61, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.27, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32291,10 +37388,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.1, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32310,10 +37410,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32329,10 +37432,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32348,10 +37454,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.81, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32367,10 +37476,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32386,10 +37498,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32405,10 +37520,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32424,10 +37542,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32443,10 +37564,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32462,10 +37586,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32481,10 +37608,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.18, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32500,10 +37630,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.352, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32519,10 +37652,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.292, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32538,10 +37674,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32557,10 +37696,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32576,10 +37718,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32595,10 +37740,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32614,10 +37762,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32633,10 +37784,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32652,10 +37806,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32671,10 +37828,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32690,10 +37850,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32709,10 +37872,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32728,10 +37894,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32747,10 +37916,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32766,10 +37938,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32785,10 +37960,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32804,10 +37982,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32823,10 +38004,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32842,10 +38026,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32861,10 +38048,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32880,10 +38070,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32899,10 +38092,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32918,10 +38114,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32937,10 +38136,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32956,10 +38158,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32975,10 +38180,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -32994,10 +38202,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33013,10 +38224,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33032,10 +38246,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33051,10 +38268,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33070,10 +38290,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.77, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33089,10 +38312,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.77, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33108,10 +38334,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.62, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33127,10 +38356,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33146,10 +38378,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33165,10 +38400,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33184,10 +38422,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33203,10 +38444,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33222,10 +38466,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33241,10 +38488,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33260,10 +38510,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33279,10 +38532,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33298,10 +38554,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33317,10 +38576,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33336,10 +38598,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33355,10 +38620,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33374,10 +38642,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33393,10 +38664,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33412,10 +38686,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33431,10 +38708,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33450,10 +38730,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33469,10 +38752,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33488,10 +38774,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.034, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33507,10 +38796,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33526,10 +38818,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33545,10 +38840,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33564,10 +38862,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.218, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33583,10 +38884,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.081, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33602,10 +38906,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.167, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33621,10 +38928,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33640,10 +38950,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33659,10 +38972,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.093, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33678,10 +38994,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33697,10 +39016,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33716,10 +39038,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33735,10 +39060,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33754,10 +39082,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33773,10 +39104,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33792,10 +39126,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33811,10 +39148,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.107, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33830,10 +39170,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.087, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33849,10 +39192,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33868,10 +39214,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33887,10 +39236,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33906,10 +39258,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.069, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33925,10 +39280,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33944,10 +39302,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33963,10 +39324,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.066, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -33982,10 +39346,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34001,10 +39368,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34020,10 +39390,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34039,10 +39412,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.081, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34058,10 +39434,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34077,10 +39456,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34096,10 +39478,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.218, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34115,10 +39500,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.055, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34134,10 +39522,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.055, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34153,10 +39544,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.097, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34172,10 +39566,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34191,10 +39588,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34210,10 +39610,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.123, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34229,10 +39632,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34248,10 +39654,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.093, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34267,10 +39676,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.093, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34286,10 +39698,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34305,10 +39720,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34324,10 +39742,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34343,10 +39764,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34362,10 +39786,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34381,10 +39808,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34400,10 +39830,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34419,10 +39852,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34438,10 +39874,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34457,10 +39896,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34476,10 +39918,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34495,10 +39940,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34514,10 +39962,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34533,10 +39984,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34552,10 +40006,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34571,10 +40028,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34590,10 +40050,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34609,10 +40072,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.1, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34628,10 +40094,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.1, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34647,10 +40116,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34666,10 +40138,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34685,10 +40160,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34704,10 +40182,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34723,10 +40204,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34742,10 +40226,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34761,10 +40248,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34780,10 +40270,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34799,10 +40292,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34818,10 +40314,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34837,10 +40336,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34856,10 +40358,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.27, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34875,10 +40380,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.27, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34894,10 +40402,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34913,10 +40424,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34932,10 +40446,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34951,10 +40468,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34970,10 +40490,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -34989,10 +40512,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35008,10 +40534,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35027,10 +40556,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35046,10 +40578,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35065,10 +40600,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35084,10 +40622,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35103,10 +40644,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35122,10 +40666,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35141,10 +40688,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.107, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35160,10 +40710,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35179,10 +40732,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35198,10 +40754,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.087, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35217,10 +40776,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35236,10 +40798,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35255,10 +40820,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35274,10 +40842,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.069, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35293,10 +40864,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.066, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35312,10 +40886,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35331,10 +40908,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.055, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35350,10 +40930,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35369,10 +40952,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35388,10 +40974,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35407,10 +40996,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35426,10 +41018,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.055, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35445,10 +41040,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.173, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35464,10 +41062,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.053, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35483,10 +41084,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.097, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35502,10 +41106,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35521,10 +41128,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.123, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35540,10 +41150,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.084, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35559,10 +41172,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.084, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35578,10 +41194,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35597,10 +41216,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.104, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35616,10 +41238,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.084, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35635,10 +41260,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35654,10 +41282,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35673,10 +41304,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35692,10 +41326,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35711,10 +41348,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35730,10 +41370,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35749,10 +41392,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35768,10 +41414,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35787,10 +41436,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.6, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35806,10 +41458,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35825,10 +41480,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35844,10 +41502,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.6, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35863,10 +41524,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35882,10 +41546,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35901,10 +41568,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35920,10 +41590,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35939,10 +41612,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35958,10 +41634,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35977,10 +41656,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -35996,10 +41678,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36015,10 +41700,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.9, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36034,10 +41722,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36053,10 +41744,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.09, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36072,10 +41766,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36091,10 +41788,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36110,10 +41810,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36129,10 +41832,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36148,10 +41854,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36167,10 +41876,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36186,10 +41898,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.17, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36205,10 +41920,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.17, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36224,10 +41942,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36243,10 +41964,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.3, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36262,10 +41986,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.3, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36281,10 +42008,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.65, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36300,10 +42030,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.69, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.27, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36319,10 +42052,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.69, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.27, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36338,10 +42074,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36357,10 +42096,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36376,10 +42118,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36395,10 +42140,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36414,10 +42162,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36433,10 +42184,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36452,10 +42206,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36471,10 +42228,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.087, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36490,10 +42250,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36509,10 +42272,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36528,10 +42294,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.074, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36547,10 +42316,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36566,10 +42338,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36585,10 +42360,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.137, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36604,10 +42382,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.069, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36623,10 +42404,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.066, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36642,10 +42426,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36661,10 +42448,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.055, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36680,10 +42470,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36699,10 +42492,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36718,10 +42514,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.055, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36737,10 +42536,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36756,10 +42558,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36775,10 +42580,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.173, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36794,10 +42602,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.053, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36813,10 +42624,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.097, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36832,10 +42646,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36851,10 +42668,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.104, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36870,10 +42690,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.084, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36889,10 +42712,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36908,10 +42734,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36927,10 +42756,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.09, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36946,10 +42778,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.084, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36965,10 +42800,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -36984,10 +42822,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37003,10 +42844,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37022,10 +42866,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37041,10 +42888,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37060,10 +42910,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37079,10 +42932,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37098,10 +42954,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.4, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37117,10 +42976,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37136,10 +42998,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37155,10 +43020,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.4, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37174,10 +43042,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37193,10 +43064,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37212,10 +43086,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37231,10 +43108,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37250,10 +43130,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37269,10 +43152,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.85, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37288,10 +43174,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.85, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37307,10 +43196,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37326,10 +43218,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37345,10 +43240,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.86, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37364,10 +43262,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.54, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37383,10 +43284,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.86, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37402,10 +43306,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37421,10 +43328,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37440,10 +43350,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37459,10 +43372,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37478,10 +43394,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37497,10 +43416,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37516,10 +43438,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.17, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37535,10 +43460,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37554,10 +43482,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37573,10 +43504,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.3, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37592,10 +43526,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.3, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37611,10 +43548,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37630,10 +43570,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.69, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37649,10 +43592,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37668,10 +43614,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37687,10 +43636,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37706,10 +43658,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37725,10 +43680,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37744,10 +43702,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37763,10 +43724,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37782,10 +43746,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37801,10 +43768,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.074, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37820,10 +43790,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37839,10 +43812,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37858,10 +43834,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37877,10 +43856,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37896,10 +43878,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37915,10 +43900,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.137, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37934,10 +43922,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37953,10 +43944,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37972,10 +43966,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -37991,10 +43988,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.055, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38010,10 +44010,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38029,10 +44032,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38048,10 +44054,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.055, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38067,10 +44076,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38086,10 +44098,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38105,10 +44120,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.119, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38124,10 +44142,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.053, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38143,10 +44164,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.083, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38162,10 +44186,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38181,10 +44208,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.09, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38200,10 +44230,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.069, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38219,10 +44252,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38238,10 +44274,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38257,10 +44296,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.08, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38276,10 +44318,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.069, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38295,10 +44340,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38314,10 +44362,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38333,10 +44384,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38352,10 +44406,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38371,10 +44428,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38390,10 +44450,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38409,10 +44472,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38428,10 +44494,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38447,10 +44516,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38466,10 +44538,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38485,10 +44560,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38504,10 +44582,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38523,10 +44604,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38542,10 +44626,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38561,10 +44648,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38580,10 +44670,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38599,10 +44692,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38618,10 +44714,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38637,10 +44736,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38656,10 +44758,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38675,10 +44780,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.86, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38694,10 +44802,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.54, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38713,10 +44824,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.86, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38732,10 +44846,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38751,10 +44868,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38770,10 +44890,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38789,10 +44912,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38808,10 +44934,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38827,10 +44956,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38846,10 +44978,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.17, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38865,10 +45000,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.17, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38884,10 +45022,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.65, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38903,10 +45044,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.1, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.62, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38922,10 +45066,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.1, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.27, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38941,10 +45088,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38960,10 +45110,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.69, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38979,10 +45132,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.69, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -38998,10 +45154,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39017,10 +45176,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39036,10 +45198,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39055,10 +45220,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39074,10 +45242,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39093,10 +45264,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39112,10 +45286,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39131,10 +45308,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39150,10 +45330,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39169,10 +45352,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39188,10 +45374,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.057, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39207,10 +45396,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39226,10 +45418,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39245,10 +45440,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.137, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39264,10 +45462,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39283,10 +45484,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39302,10 +45506,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39321,10 +45528,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.049, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39340,10 +45550,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39359,10 +45572,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39378,10 +45594,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.049, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39397,10 +45616,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39416,10 +45638,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39435,10 +45660,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.093, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39454,10 +45682,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.034, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39473,10 +45704,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.072, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39492,10 +45726,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39511,10 +45748,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.08, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39530,10 +45770,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.069, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39549,10 +45792,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39568,10 +45814,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39587,10 +45836,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.071, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39606,10 +45858,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.069, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39625,10 +45880,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39644,10 +45902,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39663,10 +45924,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39682,10 +45946,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39701,10 +45968,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39720,10 +45990,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39739,10 +46012,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39758,10 +46034,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39777,10 +46056,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39796,10 +46078,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39815,10 +46100,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39834,10 +46122,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39853,10 +46144,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39872,10 +46166,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39891,10 +46188,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.6, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39910,10 +46210,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39929,10 +46232,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39948,10 +46254,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39967,10 +46276,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -39986,10 +46298,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.54, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40005,10 +46320,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.86, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40024,10 +46342,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.52, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40043,10 +46364,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.688, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40062,10 +46386,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40081,10 +46408,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40100,10 +46430,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40119,10 +46452,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40138,10 +46474,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40157,10 +46496,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40176,10 +46518,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.17, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40195,10 +46540,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40214,10 +46562,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40233,10 +46584,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.87, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40252,10 +46606,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.74, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40271,10 +46628,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40290,10 +46650,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.69, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40309,10 +46672,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40328,10 +46694,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.77, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40347,10 +46716,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40366,10 +46738,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40385,10 +46760,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40404,10 +46782,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40423,10 +46804,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40442,10 +46826,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40461,10 +46848,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40480,10 +46870,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40499,10 +46892,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40518,10 +46914,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40537,10 +46936,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40556,10 +46958,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40575,10 +46980,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.107, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40594,10 +47002,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40613,10 +47024,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40632,10 +47046,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40651,10 +47068,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.049, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40670,10 +47090,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40689,10 +47112,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40708,10 +47134,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.049, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40727,10 +47156,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40746,10 +47178,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40765,10 +47200,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.093, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40784,10 +47222,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.034, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40803,10 +47244,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.072, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40822,10 +47266,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40841,10 +47288,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.071, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40860,10 +47310,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.057, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40879,10 +47332,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40898,10 +47354,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40917,10 +47376,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.071, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40936,10 +47398,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.057, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40955,10 +47420,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.042, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40974,10 +47442,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -40993,10 +47464,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.123, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41012,10 +47486,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41031,10 +47508,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41050,10 +47530,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41069,10 +47552,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41088,10 +47574,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41107,10 +47596,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.4, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41126,10 +47618,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41145,10 +47640,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41164,10 +47662,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.4, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41183,10 +47684,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41202,10 +47706,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41221,10 +47728,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.6, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41240,10 +47750,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41259,10 +47772,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41278,10 +47794,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41297,10 +47816,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41316,10 +47838,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.52, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41335,10 +47860,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.843, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41354,10 +47882,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.52, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41373,10 +47904,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.688, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41392,10 +47926,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41411,10 +47948,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.9, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41430,10 +47970,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41449,10 +47992,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41468,10 +48014,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.092, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41487,10 +48036,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41506,10 +48058,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.17, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.77, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41525,10 +48080,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.17, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.62, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41544,10 +48102,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41563,10 +48124,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.87, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41582,10 +48146,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.61, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41601,10 +48168,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41620,10 +48190,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.69, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41639,10 +48212,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.69, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41658,10 +48234,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41677,10 +48256,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41696,10 +48278,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41715,10 +48300,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41734,10 +48322,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41753,10 +48344,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41772,10 +48366,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41791,10 +48388,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.057, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41810,10 +48410,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41829,10 +48432,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41848,10 +48454,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41867,10 +48476,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41886,10 +48498,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41905,10 +48520,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.087, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41924,10 +48542,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41943,10 +48564,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41962,10 +48586,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -41981,10 +48608,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.035, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42000,10 +48630,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42019,10 +48652,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.021, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42038,10 +48674,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.035, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42057,10 +48696,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42076,10 +48718,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.021, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42095,10 +48740,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42114,10 +48762,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42133,10 +48784,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.034, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42152,10 +48806,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42171,10 +48828,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.071, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42190,10 +48850,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.057, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42209,10 +48872,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42228,10 +48894,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.036, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42247,10 +48916,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42266,10 +48938,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.057, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42285,10 +48960,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.037, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42304,10 +48982,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.036, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42323,10 +49004,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.104, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42342,10 +49026,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42361,10 +49048,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.084, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42380,10 +49070,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42399,10 +49092,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42418,10 +49114,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42437,10 +49136,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.4, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42456,10 +49158,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42475,10 +49180,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42494,10 +49202,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.4, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42513,10 +49224,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42532,10 +49246,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42551,10 +49268,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.6, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42570,10 +49290,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42589,10 +49312,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42608,10 +49334,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42627,10 +49356,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42646,10 +49378,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.52, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42665,10 +49400,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.688, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42684,10 +49422,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.51, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42703,10 +49444,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.688, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42722,10 +49466,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42741,10 +49488,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.9, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42760,10 +49510,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42779,10 +49532,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42798,10 +49554,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.075, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42817,10 +49576,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42836,10 +49598,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42855,10 +49620,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.46, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42874,10 +49642,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.3, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42893,10 +49664,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.61, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42912,10 +49686,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.61, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42931,10 +49708,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.1, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.71, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42950,10 +49730,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.65, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42969,10 +49752,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.55, "assembly_minimum_vt_shgc": null, "annotation": null @@ -42988,10 +49774,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.81, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43007,10 +49796,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43026,10 +49818,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43045,10 +49840,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.093, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43064,10 +49862,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43083,10 +49884,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43102,10 +49906,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43121,10 +49928,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43140,10 +49950,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.352, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43159,10 +49972,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.292, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43178,10 +49994,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43197,10 +50016,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43216,10 +50038,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43235,10 +50060,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43254,10 +50082,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43273,10 +50104,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43292,10 +50126,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43311,10 +50148,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43330,10 +50170,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43349,10 +50192,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43368,10 +50214,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43387,10 +50236,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43406,10 +50258,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43425,10 +50280,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43444,10 +50302,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43463,10 +50324,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43482,10 +50346,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43501,10 +50368,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43520,10 +50390,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43539,10 +50412,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43558,10 +50434,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43577,10 +50456,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43596,10 +50478,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43615,10 +50500,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43634,10 +50522,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43653,10 +50544,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43672,10 +50566,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43691,10 +50588,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43710,10 +50610,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43729,10 +50632,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43748,10 +50654,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43767,10 +50676,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43786,10 +50698,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43805,10 +50720,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43824,10 +50742,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43843,10 +50764,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43862,10 +50786,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43881,10 +50808,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43900,10 +50830,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43919,10 +50852,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43938,10 +50874,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43957,10 +50896,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43976,10 +50918,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -43995,10 +50940,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44014,10 +50962,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44033,10 +50984,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44052,10 +51006,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44071,10 +51028,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44090,10 +51050,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44109,10 +51072,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.041, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44128,10 +51094,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44147,10 +51116,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44166,10 +51138,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.041, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44185,10 +51160,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44204,10 +51182,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.218, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44223,10 +51204,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.1156, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44242,10 +51226,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.081, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44261,10 +51248,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44280,10 +51270,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44299,10 +51292,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.094, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44318,10 +51314,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44337,10 +51336,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44356,10 +51358,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44375,10 +51380,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44394,10 +51402,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44413,10 +51424,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44432,10 +51446,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44451,10 +51468,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.107, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44470,10 +51490,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44489,10 +51512,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44508,10 +51534,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.087, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44527,10 +51556,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44546,10 +51578,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44565,10 +51600,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44584,10 +51622,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.069, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44603,10 +51644,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.066, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44622,10 +51666,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44641,10 +51688,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44660,10 +51710,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.041, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44679,10 +51732,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44698,10 +51754,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44717,10 +51776,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.041, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44736,10 +51798,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44755,10 +51820,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.173, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44774,10 +51842,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.096, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44793,10 +51864,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.053, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44812,10 +51886,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44831,10 +51908,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44850,10 +51930,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.094, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44869,10 +51952,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.084, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44888,10 +51974,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44907,10 +51996,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.123, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44926,10 +52018,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.094, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44945,10 +52040,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44964,10 +52062,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -44983,10 +52084,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45002,10 +52106,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.162, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45021,10 +52128,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45040,10 +52150,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45059,10 +52172,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45078,10 +52194,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.4, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -45097,10 +52216,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -45116,10 +52238,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.83, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -45135,10 +52260,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.4, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -45154,10 +52282,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -45173,10 +52304,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -45192,10 +52326,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.93, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45211,10 +52348,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45230,10 +52370,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.83, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45249,10 +52392,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -45268,10 +52414,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -45287,10 +52436,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45306,10 +52458,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45325,10 +52480,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.9, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45344,10 +52502,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45363,10 +52524,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.86, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45382,10 +52546,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45401,10 +52568,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45420,10 +52590,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45439,10 +52612,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45458,10 +52634,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45477,10 +52656,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45496,10 +52678,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45515,10 +52700,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45534,10 +52722,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.77, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45553,10 +52744,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.77, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45572,10 +52766,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.77, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45591,10 +52788,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45610,10 +52810,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45629,10 +52832,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.68, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45648,10 +52854,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.64, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45667,10 +52876,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45686,10 +52898,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45705,10 +52920,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45724,10 +52942,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45743,10 +52964,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45762,10 +52986,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45781,10 +53008,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.074, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45800,10 +53030,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45819,10 +53052,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45838,10 +53074,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.074, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45857,10 +53096,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45876,10 +53118,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45895,10 +53140,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.137, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45914,10 +53162,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45933,10 +53184,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45952,10 +53206,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45971,10 +53228,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -45990,10 +53250,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.041, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46009,10 +53272,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46028,10 +53294,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46047,10 +53316,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.041, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46066,10 +53338,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46085,10 +53360,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.119, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46104,10 +53382,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.096, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46123,10 +53404,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.053, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46142,10 +53426,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46161,10 +53448,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.123, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46180,10 +53470,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.094, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46199,10 +53492,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.077, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46218,10 +53514,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46237,10 +53536,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.104, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46256,10 +53558,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.072, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46275,10 +53580,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46294,10 +53602,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46313,10 +53624,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46332,10 +53646,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.162, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46351,10 +53668,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46370,10 +53690,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46389,10 +53712,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46408,10 +53734,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -46427,10 +53756,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -46446,10 +53778,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -46465,10 +53800,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -46484,10 +53822,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -46503,10 +53844,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.68, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -46522,10 +53866,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.87, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46541,10 +53888,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46560,10 +53910,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46579,10 +53932,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.6, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -46598,10 +53954,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.6, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -46617,10 +53976,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46636,10 +53998,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46655,10 +54020,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.86, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46674,10 +54042,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.54, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46693,10 +54064,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.86, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46712,10 +54086,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46731,10 +54108,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46750,10 +54130,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46769,10 +54152,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46788,10 +54174,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46807,10 +54196,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46826,10 +54218,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.64, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46845,10 +54240,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46864,10 +54262,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46883,10 +54284,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46902,10 +54306,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46921,10 +54328,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46940,10 +54350,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46959,10 +54372,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46978,10 +54394,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -46997,10 +54416,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47016,10 +54438,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47035,10 +54460,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47054,10 +54482,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47073,10 +54504,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47092,10 +54526,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47111,10 +54548,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.057, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47130,10 +54570,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47149,10 +54592,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47168,10 +54614,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47187,10 +54636,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47206,10 +54658,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47225,10 +54680,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.107, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47244,10 +54702,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47263,10 +54724,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47282,10 +54746,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47301,10 +54768,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47320,10 +54790,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.037, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47339,10 +54812,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.021, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47358,10 +54834,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47377,10 +54856,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.037, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47396,10 +54878,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.021, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47415,10 +54900,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.093, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47434,10 +54922,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.082, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47453,10 +54944,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.034, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47472,10 +54966,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47491,10 +54988,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.104, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47510,10 +55010,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.06, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47529,10 +55032,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47548,10 +55054,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47567,10 +55076,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.09, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47586,10 +55098,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.05, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47605,10 +55120,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47624,10 +55142,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47643,10 +55164,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47662,10 +55186,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.162, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47681,10 +55208,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47700,10 +55230,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47719,10 +55252,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47738,10 +55274,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -47757,10 +55296,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.42, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -47776,10 +55318,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -47795,10 +55340,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.42, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -47814,10 +55362,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.68, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -47833,10 +55384,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.51, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47852,10 +55406,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.73, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47871,10 +55428,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47890,10 +55450,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -47909,10 +55472,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -47928,10 +55494,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -47947,10 +55516,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.81, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47966,10 +55538,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.52, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -47985,10 +55560,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.843, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48004,10 +55582,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.52, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48023,10 +55604,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.688, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48042,10 +55626,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48061,10 +55648,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.9, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48080,10 +55670,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48099,10 +55692,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48118,10 +55714,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.092, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48137,10 +55736,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48156,10 +55758,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48175,10 +55780,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48194,10 +55802,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.15, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48213,10 +55824,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48232,10 +55846,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48251,10 +55868,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.15, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48270,10 +55890,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48289,10 +55912,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48308,10 +55934,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.15, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48327,10 +55956,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48346,10 +55978,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48365,10 +56000,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48384,10 +56022,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48403,10 +56044,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48422,10 +56066,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48441,10 +56088,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.057, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48460,10 +56110,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48479,10 +56132,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48498,10 +56154,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48517,10 +56176,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48536,10 +56198,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48555,10 +56220,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.107, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48574,10 +56242,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48593,10 +56264,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48612,10 +56286,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48631,10 +56308,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48650,10 +56330,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.037, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48669,10 +56352,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.021, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48688,10 +56374,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48707,10 +56396,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.037, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48726,10 +56418,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.021, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48745,10 +56440,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48764,10 +56462,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.082, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48783,10 +56484,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.034, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48802,10 +56506,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48821,10 +56528,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.09, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48840,10 +56550,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.05, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48859,10 +56572,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.055, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48878,10 +56594,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48897,10 +56616,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.08, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48916,10 +56638,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.05, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48935,10 +56660,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.055, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48954,10 +56682,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48973,10 +56704,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -48992,10 +56726,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.094, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49011,10 +56748,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.084, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49030,10 +56770,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49049,10 +56792,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49068,10 +56814,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.32, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -49087,10 +56836,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.42, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -49106,10 +56858,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.32, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -49125,10 +56880,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.42, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -49144,10 +56902,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.68, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -49163,10 +56924,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49182,10 +56946,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.62, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49201,10 +56968,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49220,10 +56990,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -49239,10 +57012,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -49258,10 +57034,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -49277,10 +57056,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49296,10 +57078,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.52, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49315,10 +57100,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.688, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49334,10 +57122,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.51, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49353,10 +57144,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.688, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49372,10 +57166,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49391,10 +57188,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.9, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49410,10 +57210,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49429,10 +57232,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49448,10 +57254,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.092, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49467,10 +57276,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49486,10 +57298,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49505,10 +57320,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49524,10 +57342,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49543,10 +57364,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49562,10 +57386,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.34, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49581,10 +57408,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.27, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49600,10 +57430,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49619,10 +57452,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49638,10 +57474,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49657,10 +57496,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49676,10 +57518,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49695,10 +57540,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49714,10 +57562,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49733,10 +57584,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49752,10 +57606,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49771,10 +57628,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49790,10 +57650,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49809,10 +57672,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49828,10 +57694,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49847,10 +57716,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49866,10 +57738,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49885,10 +57760,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.087, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49904,10 +57782,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49923,10 +57804,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49942,10 +57826,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49961,10 +57848,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49980,10 +57870,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.031, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -49999,10 +57892,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.021, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50018,10 +57914,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50037,10 +57936,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.029, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50056,10 +57958,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.021, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50075,10 +57980,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50094,10 +58002,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.06, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50113,10 +58024,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.034, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50132,10 +58046,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50151,10 +58068,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.08, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50170,10 +58090,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.05, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50189,10 +58112,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.049, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50208,10 +58134,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50227,10 +58156,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.071, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50246,10 +58178,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.05, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50265,10 +58200,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.049, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50284,10 +58222,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50303,10 +58244,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50322,10 +58266,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.094, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50341,10 +58288,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.084, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50360,10 +58310,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50379,10 +58332,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50398,10 +58354,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.32, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -50417,10 +58376,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.42, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -50436,10 +58398,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -50455,10 +58420,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.32, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -50474,10 +58442,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.42, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -50493,10 +58464,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.68, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -50512,10 +58486,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50531,10 +58508,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.51, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50550,10 +58530,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50569,10 +58552,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -50588,10 +58574,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -50607,10 +58596,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.59, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50626,10 +58618,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.51, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50645,10 +58640,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.688, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50664,10 +58662,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.434, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50683,10 +58684,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.671, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50702,10 +58706,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50721,10 +58728,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.86, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50740,10 +58750,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50759,10 +58772,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.092, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50778,10 +58794,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.063, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50797,10 +58816,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50816,10 +58838,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50835,10 +58860,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50854,10 +58882,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.85, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50873,10 +58904,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50892,10 +58926,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50911,10 +58948,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.85, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50930,10 +58970,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50949,10 +58992,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50968,10 +59014,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.85, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -50987,10 +59036,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51006,10 +59058,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51025,10 +59080,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51044,10 +59102,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51063,10 +59124,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51082,10 +59146,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51101,10 +59168,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.042, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51120,10 +59190,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51139,10 +59212,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51158,10 +59234,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.042, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51177,10 +59256,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51196,10 +59278,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.27, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51215,10 +59300,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.074, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51234,10 +59322,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51253,10 +59344,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51272,10 +59366,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51291,10 +59388,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.028, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51310,10 +59410,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.029, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51329,10 +59432,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.017, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51348,10 +59454,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.028, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51367,10 +59476,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.029, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51386,10 +59498,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.017, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51405,10 +59520,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51424,10 +59542,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.037, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51443,10 +59564,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51462,10 +59586,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51481,10 +59608,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.071, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51500,10 +59630,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.044, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51519,10 +59652,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.049, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51538,10 +59674,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51557,10 +59696,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.071, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51576,10 +59718,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.044, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51595,10 +59740,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.042, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51614,10 +59762,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51633,10 +59784,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.123, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51652,10 +59806,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.072, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51671,10 +59828,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51690,10 +59850,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51709,10 +59872,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51728,10 +59894,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.32, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -51747,10 +59916,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.38, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -51766,10 +59938,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -51785,10 +59960,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.32, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -51804,10 +59982,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.38, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -51823,10 +60004,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.68, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -51842,10 +60026,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.32, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51861,10 +60048,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.38, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51880,10 +60070,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51899,10 +60092,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.4, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -51918,10 +60114,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.4, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -51937,10 +60136,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.44, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51956,10 +60158,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.51, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51975,10 +60180,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.671, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -51994,10 +60202,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.434, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52013,10 +60224,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.671, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52032,10 +60246,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52051,10 +60268,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.86, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52070,10 +60290,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52089,10 +60312,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.063, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52108,10 +60334,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.063, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52127,10 +60356,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52146,10 +60378,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.27, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52165,10 +60400,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.27, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52184,10 +60422,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.85, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52203,10 +60444,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52222,10 +60466,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52241,10 +60488,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.85, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52260,10 +60510,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52279,10 +60532,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52298,10 +60554,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.85, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52317,10 +60576,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52336,10 +60598,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52355,10 +60620,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52374,10 +60642,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52393,10 +60664,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52412,10 +60686,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52431,10 +60708,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52450,10 +60730,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52469,10 +60752,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52488,10 +60774,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52507,10 +60796,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52526,10 +60818,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52545,10 +60840,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52564,10 +60862,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52583,10 +60884,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52602,10 +60906,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52621,10 +60928,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.028, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52640,10 +60950,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.026, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52659,10 +60972,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.017, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52678,10 +60994,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.028, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52697,10 +61016,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.026, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52716,10 +61038,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.017, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52735,10 +61060,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52754,10 +61082,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.037, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52773,10 +61104,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52792,10 +61126,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52811,10 +61148,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52830,10 +61170,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52849,10 +61192,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.037, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52868,10 +61214,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52887,10 +61236,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52906,10 +61258,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52925,10 +61280,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.037, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52944,10 +61302,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52963,10 +61324,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.104, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -52982,10 +61346,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.06, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53001,10 +61368,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53020,10 +61390,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53039,10 +61412,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53058,10 +61434,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.32, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -53077,10 +61456,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.38, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -53096,10 +61478,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -53115,10 +61500,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.32, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -53134,10 +61522,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.38, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -53153,10 +61544,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.68, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -53172,10 +61566,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.32, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53191,10 +61588,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.38, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53210,10 +61610,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53229,10 +61632,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.4, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -53248,10 +61654,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.4, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -53267,10 +61676,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.44, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53286,10 +61698,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.434, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53305,10 +61720,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.671, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53324,10 +61742,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.424, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53343,10 +61764,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.373, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53362,10 +61786,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.54, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53381,10 +61808,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.86, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53400,10 +61830,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53419,10 +61852,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.063, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53438,10 +61874,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.063, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53457,10 +61896,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53476,10 +61918,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53495,10 +61940,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53514,10 +61962,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.85, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53533,10 +61984,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53552,10 +62006,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.65, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53571,10 +62028,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.85, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.27, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53590,10 +62050,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53609,10 +62072,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53628,10 +62094,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.85, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53647,10 +62116,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53666,10 +62138,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53685,10 +62160,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.094, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53704,10 +62182,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53723,10 +62204,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53742,10 +62226,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53761,10 +62248,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.352, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53780,10 +62270,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.352, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53799,10 +62292,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.292, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53818,10 +62314,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53837,10 +62336,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -53856,10 +62358,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -53875,10 +62380,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.1, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -53894,10 +62402,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -53913,10 +62424,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -53932,10 +62446,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.1, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -53951,10 +62468,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.93, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53970,10 +62490,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -53989,10 +62512,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.1, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54008,10 +62534,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -54027,10 +62556,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -54046,10 +62578,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54065,10 +62600,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54084,10 +62622,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54103,10 +62644,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54122,10 +62666,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54141,10 +62688,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54160,10 +62710,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54179,10 +62732,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54198,10 +62754,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54217,10 +62776,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54236,10 +62798,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54255,10 +62820,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54274,10 +62842,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54293,10 +62864,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54312,10 +62886,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54331,10 +62908,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54350,10 +62930,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54369,10 +62952,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.68, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54388,10 +62974,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.64, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54407,10 +62996,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.64, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54426,10 +63018,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -54445,10 +63040,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -54464,10 +63062,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -54483,10 +63084,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -54502,10 +63106,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54521,10 +63128,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54540,10 +63150,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54559,10 +63172,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54578,10 +63194,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54597,10 +63216,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54616,10 +63238,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54635,10 +63260,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54654,10 +63282,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54673,10 +63304,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54692,10 +63326,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54711,10 +63348,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54730,10 +63370,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54749,10 +63392,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.041, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54768,10 +63414,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54787,10 +63436,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54806,10 +63458,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.041, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54825,10 +63480,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54844,10 +63502,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.218, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54863,10 +63524,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.1156, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54882,10 +63546,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.081, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54901,10 +63568,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54920,10 +63590,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54939,10 +63612,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.094, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54958,10 +63634,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -54977,10 +63656,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -54996,10 +63678,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -55015,10 +63700,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -55034,10 +63722,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -55053,10 +63744,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55072,10 +63766,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55091,10 +63788,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.107, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55110,10 +63810,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55129,10 +63832,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55148,10 +63854,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.087, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55167,10 +63876,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55186,10 +63898,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55205,10 +63920,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55224,10 +63942,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.069, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55243,10 +63964,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.066, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55262,10 +63986,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55281,10 +64008,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55300,10 +64030,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.041, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55319,10 +64052,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55338,10 +64074,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55357,10 +64096,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.041, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55376,10 +64118,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55395,10 +64140,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.173, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55414,10 +64162,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.096, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55433,10 +64184,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.053, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55452,10 +64206,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55471,10 +64228,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55490,10 +64250,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.094, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55509,10 +64272,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.084, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55528,10 +64294,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55547,10 +64316,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.123, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55566,10 +64338,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.094, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55585,10 +64360,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55604,10 +64382,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55623,10 +64404,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55642,10 +64426,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.162, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55661,10 +64448,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55680,10 +64470,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55699,10 +64492,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55718,10 +64514,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -55737,10 +64536,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.54, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -55756,10 +64558,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.83, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -55775,10 +64580,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -55794,10 +64602,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.54, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -55813,10 +64624,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -55832,10 +64646,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.93, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55851,10 +64668,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55870,10 +64690,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.83, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55889,10 +64712,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -55908,10 +64734,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -55927,10 +64756,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55946,10 +64778,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55965,10 +64800,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.9, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -55984,10 +64822,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56003,10 +64844,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.86, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56022,10 +64866,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56041,10 +64888,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56060,10 +64910,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56079,10 +64932,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56098,10 +64954,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56117,10 +64976,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56136,10 +64998,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.35, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56155,10 +65020,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.35, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56174,10 +65042,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.55, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56193,10 +65064,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.35, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56212,10 +65086,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.35, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56231,10 +65108,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.55, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56250,10 +65130,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.35, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56269,10 +65152,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.35, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56288,10 +65174,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.55, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56307,10 +65196,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -56326,10 +65218,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -56345,10 +65240,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -56364,10 +65262,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -56383,10 +65284,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -56402,10 +65306,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -56421,10 +65328,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.074, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56440,10 +65350,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56459,10 +65372,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56478,10 +65394,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.074, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56497,10 +65416,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56516,10 +65438,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56535,10 +65460,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.137, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56554,10 +65482,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56573,10 +65504,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56592,10 +65526,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56611,10 +65548,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56630,10 +65570,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.041, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56649,10 +65592,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56668,10 +65614,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56687,10 +65636,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.041, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56706,10 +65658,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56725,10 +65680,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.119, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56744,10 +65702,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.096, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56763,10 +65724,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.053, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56782,10 +65746,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56801,10 +65768,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.123, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56820,10 +65790,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.094, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56839,10 +65812,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.077, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56858,10 +65834,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56877,10 +65856,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.104, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56896,10 +65878,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.072, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56915,10 +65900,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56934,10 +65922,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56953,10 +65944,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56972,10 +65966,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.162, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -56991,10 +65988,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57010,10 +66010,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57029,10 +66032,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57048,10 +66054,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.33, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -57067,10 +66076,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -57086,10 +66098,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -57105,10 +66120,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.33, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -57124,10 +66142,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -57143,10 +66164,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.68, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -57162,10 +66186,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.87, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57181,10 +66208,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57200,10 +66230,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57219,10 +66252,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.6, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -57238,10 +66274,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.6, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -57257,10 +66296,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57276,10 +66318,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57295,10 +66340,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.86, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57314,10 +66362,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.54, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57333,10 +66384,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.86, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57352,10 +66406,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57371,10 +66428,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57390,10 +66450,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57409,10 +66472,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57428,10 +66494,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57447,10 +66516,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57466,10 +66538,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.35, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57485,10 +66560,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.35, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57504,10 +66582,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57523,10 +66604,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.35, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57542,10 +66626,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.35, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57561,10 +66648,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57580,10 +66670,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.35, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57599,10 +66692,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.35, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57618,10 +66714,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57637,10 +66736,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -57656,10 +66758,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -57675,10 +66780,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -57694,10 +66802,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -57713,10 +66824,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -57732,10 +66846,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -57751,10 +66868,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.057, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57770,10 +66890,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57789,10 +66912,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57808,10 +66934,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57827,10 +66956,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57846,10 +66978,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57865,10 +67000,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.107, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57884,10 +67022,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57903,10 +67044,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57922,10 +67066,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57941,10 +67088,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57960,10 +67110,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.037, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57979,10 +67132,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.021, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -57998,10 +67154,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58017,10 +67176,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.037, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58036,10 +67198,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.021, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58055,10 +67220,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.093, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58074,10 +67242,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.082, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58093,10 +67264,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.034, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58112,10 +67286,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58131,10 +67308,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.104, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58150,10 +67330,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.06, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58169,10 +67352,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58188,10 +67374,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58207,10 +67396,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.09, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58226,10 +67418,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.05, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58245,10 +67440,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58264,10 +67462,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58283,10 +67484,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58302,10 +67506,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.162, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58321,10 +67528,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58340,10 +67550,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58359,10 +67572,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58378,10 +67594,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -58397,10 +67616,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.38, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -58416,10 +67638,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -58435,10 +67660,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.38, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -58454,10 +67682,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.68, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -58473,10 +67704,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.51, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58492,10 +67726,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.73, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58511,10 +67748,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58530,10 +67770,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.68, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -58549,10 +67792,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -58568,10 +67814,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -58587,10 +67836,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.81, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58606,10 +67858,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.52, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58625,10 +67880,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.843, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58644,10 +67902,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.52, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58663,10 +67924,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.688, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58682,10 +67946,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58701,10 +67968,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.9, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58720,10 +67990,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58739,10 +68012,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58758,10 +68034,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.092, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58777,10 +68056,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58796,10 +68078,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58815,10 +68100,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58834,10 +68122,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.15, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58853,10 +68144,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58872,10 +68166,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58891,10 +68188,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.15, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58910,10 +68210,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58929,10 +68232,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58948,10 +68254,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.15, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -58967,10 +68276,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -58986,10 +68298,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -59005,10 +68320,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -59024,10 +68342,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -59043,10 +68364,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -59062,10 +68386,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -59081,10 +68408,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.057, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59100,10 +68430,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59119,10 +68452,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59138,10 +68474,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59157,10 +68496,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59176,10 +68518,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59195,10 +68540,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.107, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59214,10 +68562,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59233,10 +68584,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59252,10 +68606,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59271,10 +68628,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59290,10 +68650,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.037, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59309,10 +68672,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.021, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59328,10 +68694,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59347,10 +68716,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.037, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59366,10 +68738,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.021, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59385,10 +68760,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59404,10 +68782,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.082, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59423,10 +68804,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.034, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59442,10 +68826,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59461,10 +68848,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.09, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59480,10 +68870,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.05, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59499,10 +68892,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.055, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59518,10 +68914,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59537,10 +68936,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.08, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59556,10 +68958,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.05, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59575,10 +68980,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.055, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59594,10 +69002,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59613,10 +69024,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59632,10 +69046,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.094, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59651,10 +69068,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.084, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59670,10 +69090,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59689,10 +69112,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59708,10 +69134,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.38, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -59727,10 +69156,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.38, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.38, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -59746,10 +69178,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.38, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -59765,10 +69200,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.38, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.38, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -59784,10 +69222,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.68, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.38, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -59803,10 +69244,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59822,10 +69266,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.62, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59841,10 +69288,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59860,10 +69310,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.68, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.38, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -59879,10 +69332,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -59898,10 +69354,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -59917,10 +69376,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59936,10 +69398,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.52, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59955,10 +69420,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.688, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59974,10 +69442,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.51, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -59993,10 +69464,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.688, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60012,10 +69486,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60031,10 +69508,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.9, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60050,10 +69530,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60069,10 +69552,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60088,10 +69574,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.092, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60107,10 +69596,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60126,10 +69618,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60145,10 +69640,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60164,10 +69662,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60183,10 +69684,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60202,10 +69706,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60221,10 +69728,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60240,10 +69750,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60259,10 +69772,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60278,10 +69794,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60297,10 +69816,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -60316,10 +69838,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -60335,10 +69860,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -60354,10 +69882,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -60373,10 +69904,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -60392,10 +69926,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -60411,10 +69948,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60430,10 +69970,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60449,10 +69992,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60468,10 +70014,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60487,10 +70036,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60506,10 +70058,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60525,10 +70080,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.087, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60544,10 +70102,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60563,10 +70124,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60582,10 +70146,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60601,10 +70168,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60620,10 +70190,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.031, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60639,10 +70212,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.021, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60658,10 +70234,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60677,10 +70256,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.029, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60696,10 +70278,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.021, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60715,10 +70300,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60734,10 +70322,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.06, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60753,10 +70344,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.034, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60772,10 +70366,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60791,10 +70388,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.08, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60810,10 +70410,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.05, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60829,10 +70432,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.049, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60848,10 +70454,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60867,10 +70476,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.071, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60886,10 +70498,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.05, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60905,10 +70520,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.049, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60924,10 +70542,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60943,10 +70564,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60962,10 +70586,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.094, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -60981,10 +70608,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.084, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61000,10 +70630,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61019,10 +70652,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61038,10 +70674,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.3, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -61057,10 +70696,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -61076,10 +70718,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.68, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -61095,10 +70740,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.3, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -61114,10 +70762,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -61133,10 +70784,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.68, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -61152,10 +70806,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61171,10 +70828,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.51, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61190,10 +70850,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61209,10 +70872,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -61228,10 +70894,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -61247,10 +70916,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.59, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61266,10 +70938,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.51, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61285,10 +70960,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.688, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61304,10 +70982,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.434, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61323,10 +71004,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.671, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61342,10 +71026,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61361,10 +71048,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.86, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61380,10 +71070,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61399,10 +71092,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.092, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61418,10 +71114,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.063, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61437,10 +71136,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61456,10 +71158,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61475,10 +71180,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61494,10 +71202,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.85, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61513,10 +71224,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61532,10 +71246,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61551,10 +71268,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.85, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61570,10 +71290,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61589,10 +71312,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61608,10 +71334,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.85, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61627,10 +71356,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -61646,10 +71378,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -61665,10 +71400,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -61684,10 +71422,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -61703,10 +71444,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -61722,10 +71466,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -61741,10 +71488,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.042, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61760,10 +71510,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61779,10 +71532,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61798,10 +71554,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.042, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61817,10 +71576,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61836,10 +71598,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.27, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61855,10 +71620,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.074, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61874,10 +71642,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61893,10 +71664,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61912,10 +71686,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61931,10 +71708,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.028, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61950,10 +71730,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.029, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61969,10 +71752,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.017, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -61988,10 +71774,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.028, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62007,10 +71796,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.029, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62026,10 +71818,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.017, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62045,10 +71840,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62064,10 +71862,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.037, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62083,10 +71884,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62102,10 +71906,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62121,10 +71928,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.071, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62140,10 +71950,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.044, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62159,10 +71972,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.049, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62178,10 +71994,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62197,10 +72016,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.071, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62216,10 +72038,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.044, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62235,10 +72060,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.042, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62254,10 +72082,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62273,10 +72104,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.123, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62292,10 +72126,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.072, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62311,10 +72148,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62330,10 +72170,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62349,10 +72192,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62368,10 +72214,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.28, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -62387,10 +72236,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.33, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -62406,10 +72258,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.68, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -62425,10 +72280,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.28, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -62444,10 +72302,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.33, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -62463,10 +72324,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.68, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -62482,10 +72346,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.32, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62501,10 +72368,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.38, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62520,10 +72390,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62539,10 +72412,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.4, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -62558,10 +72434,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.4, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -62577,10 +72456,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.44, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62596,10 +72478,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.51, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62615,10 +72500,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.671, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62634,10 +72522,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.434, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62653,10 +72544,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.671, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62672,10 +72566,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62691,10 +72588,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.86, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62710,10 +72610,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62729,10 +72632,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.063, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62748,10 +72654,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.063, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62767,10 +72676,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62786,10 +72698,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62805,10 +72720,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62824,10 +72742,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.85, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62843,10 +72764,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62862,10 +72786,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62881,10 +72808,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.85, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62900,10 +72830,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62919,10 +72852,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62938,10 +72874,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.85, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -62957,10 +72896,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -62976,10 +72918,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -62995,10 +72940,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -63014,10 +72962,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -63033,10 +72984,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -63052,10 +73006,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -63071,10 +73028,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63090,10 +73050,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63109,10 +73072,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63128,10 +73094,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63147,10 +73116,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63166,10 +73138,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63185,10 +73160,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63204,10 +73182,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63223,10 +73204,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63242,10 +73226,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63261,10 +73248,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.028, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63280,10 +73270,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.026, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63299,10 +73292,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.017, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63318,10 +73314,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.028, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63337,10 +73336,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.026, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63356,10 +73358,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.017, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63375,10 +73380,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63394,10 +73402,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.037, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63413,10 +73424,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63432,10 +73446,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63451,10 +73468,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63470,10 +73490,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63489,10 +73512,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.037, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63508,10 +73534,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63527,10 +73556,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63546,10 +73578,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63565,10 +73600,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.037, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63584,10 +73622,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63603,10 +73644,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.104, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63622,10 +73666,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.06, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63641,10 +73688,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63660,10 +73710,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63679,10 +73732,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63698,10 +73754,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.25, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -63717,10 +73776,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.29, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -63736,10 +73798,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.68, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -63755,10 +73820,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.25, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -63774,10 +73842,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.29, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -63793,10 +73864,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.68, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -63812,10 +73886,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.32, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63831,10 +73908,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.38, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63850,10 +73930,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63869,10 +73952,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.4, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -63888,10 +73974,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.4, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -63907,10 +73996,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.44, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63926,10 +74018,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.434, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63945,10 +74040,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.671, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63964,10 +74062,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.424, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -63983,10 +74084,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.373, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64002,10 +74106,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.54, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64021,10 +74128,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.86, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64040,10 +74150,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64059,10 +74172,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.063, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64078,10 +74194,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.063, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64097,10 +74216,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64116,10 +74238,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.41, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64135,10 +74260,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.41, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64154,10 +74282,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.85, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64173,10 +74304,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.41, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64192,10 +74326,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.41, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64211,10 +74348,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.85, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64230,10 +74370,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.41, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64249,10 +74392,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.41, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64268,10 +74414,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.85, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64287,10 +74436,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64306,10 +74458,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64325,10 +74480,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.094, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64344,10 +74502,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64363,10 +74524,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64382,10 +74546,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64401,10 +74568,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.352, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64420,10 +74590,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.352, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64439,10 +74612,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.292, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64458,10 +74634,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64477,10 +74656,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -64496,10 +74678,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -64515,10 +74700,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.1, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -64534,10 +74722,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -64553,10 +74744,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -64572,10 +74766,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.1, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -64591,10 +74788,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.93, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64610,10 +74810,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64629,10 +74832,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.1, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64648,10 +74854,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -64667,10 +74876,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -64686,10 +74898,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64705,10 +74920,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64724,10 +74942,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64743,10 +74964,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64762,10 +74986,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64781,10 +75008,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64800,10 +75030,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64819,10 +75052,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64838,10 +75074,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64857,10 +75096,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64876,10 +75118,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64895,10 +75140,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.35, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64914,10 +75162,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.35, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64933,10 +75184,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.55, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64952,10 +75206,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.35, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64971,10 +75228,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.35, "assembly_minimum_vt_shgc": null, "annotation": null @@ -64990,10 +75250,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.55, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65009,10 +75272,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.35, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65028,10 +75294,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.35, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65047,10 +75316,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.55, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65066,10 +75338,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -65085,10 +75360,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -65104,10 +75382,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -65123,10 +75404,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -65142,10 +75426,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65161,10 +75448,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65180,10 +75470,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65199,10 +75492,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65218,10 +75514,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65237,10 +75536,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65256,10 +75558,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65275,10 +75580,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65294,10 +75602,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65313,10 +75624,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65332,10 +75646,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65351,10 +75668,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65370,10 +75690,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65389,10 +75712,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.041, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65408,10 +75734,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65427,10 +75756,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65446,10 +75778,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.041, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65465,10 +75800,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65484,10 +75822,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.218, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65503,10 +75844,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.1156, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65522,10 +75866,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.081, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65541,10 +75888,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65560,10 +75910,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65579,10 +75932,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.094, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65598,10 +75954,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65617,10 +75976,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -65636,10 +75998,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -65655,10 +76020,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -65674,10 +76042,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -65693,10 +76064,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65712,10 +76086,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65731,10 +76108,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.107, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65750,10 +76130,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65769,10 +76152,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65788,10 +76174,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.087, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65807,10 +76196,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65826,10 +76218,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65845,10 +76240,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65864,10 +76262,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.069, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65883,10 +76284,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.066, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65902,10 +76306,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65921,10 +76328,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65940,10 +76350,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.041, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65959,10 +76372,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65978,10 +76394,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -65997,10 +76416,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.041, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66016,10 +76438,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66035,10 +76460,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.173, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66054,10 +76482,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.096, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66073,10 +76504,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.053, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66092,10 +76526,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66111,10 +76548,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66130,10 +76570,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.094, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66149,10 +76592,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.084, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66168,10 +76614,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66187,10 +76636,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.123, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66206,10 +76658,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.094, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66225,10 +76680,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66244,10 +76702,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66263,10 +76724,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66282,10 +76746,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.162, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66301,10 +76768,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66320,10 +76790,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66339,10 +76812,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66358,10 +76834,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -66377,10 +76856,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -66396,10 +76878,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.23, "assembly_minimum_vt_shgc": 1.1, "annotation": "Entrance door" @@ -66415,10 +76900,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -66434,10 +76922,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.6, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.23, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -66453,10 +76944,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.23, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -66472,10 +76966,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -66491,10 +76988,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -66510,10 +77010,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.23, "assembly_minimum_vt_shgc": 1.1, "annotation": "Entrance door" @@ -66529,10 +77032,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -66548,10 +77054,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.6, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.23, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -66567,10 +77076,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.23, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -66586,10 +77098,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Fixed" @@ -66605,10 +77120,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Fixed" @@ -66624,10 +77142,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Entrance door" @@ -66643,10 +77164,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66662,10 +77186,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66681,10 +77208,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66700,10 +77230,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -66719,10 +77252,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -66738,10 +77274,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66757,10 +77296,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66776,10 +77318,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.9, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66795,10 +77340,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66814,10 +77362,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.86, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66833,10 +77384,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66852,10 +77406,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66871,10 +77428,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66890,10 +77450,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66909,10 +77472,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66928,10 +77494,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66947,10 +77516,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.3, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66966,10 +77538,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.3, "assembly_minimum_vt_shgc": null, "annotation": null @@ -66985,10 +77560,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.55, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67004,10 +77582,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.3, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67023,10 +77604,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.3, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67042,10 +77626,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.55, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67061,10 +77648,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.3, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67080,10 +77670,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.3, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67099,10 +77692,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.55, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67118,10 +77714,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -67137,10 +77736,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -67156,10 +77758,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -67175,10 +77780,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -67194,10 +77802,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -67213,10 +77824,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -67232,10 +77846,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.074, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67251,10 +77868,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67270,10 +77890,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67289,10 +77912,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.074, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67308,10 +77934,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67327,10 +77956,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67346,10 +77978,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.137, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67365,10 +78000,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67384,10 +78022,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67403,10 +78044,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67422,10 +78066,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67441,10 +78088,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.041, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67460,10 +78110,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67479,10 +78132,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67498,10 +78154,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.041, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67517,10 +78176,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67536,10 +78198,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.119, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67555,10 +78220,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.096, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67574,10 +78242,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.053, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67593,10 +78264,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67612,10 +78286,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.123, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67631,10 +78308,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.094, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67650,10 +78330,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.077, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67669,10 +78352,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67688,10 +78374,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.104, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67707,10 +78396,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.072, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67726,10 +78418,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67745,10 +78440,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67764,10 +78462,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67783,10 +78484,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.162, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67802,10 +78506,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67821,10 +78528,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67840,10 +78550,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -67859,10 +78572,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.42, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -67878,10 +78594,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.42, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -67897,10 +78616,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.68, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.23, "assembly_minimum_vt_shgc": 1.1, "annotation": "Entrance door" @@ -67916,10 +78638,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.42, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -67935,10 +78660,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.54, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.23, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -67954,10 +78682,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.68, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.23, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -67973,10 +78704,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.42, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -67992,10 +78726,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.42, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -68011,10 +78748,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.68, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.23, "assembly_minimum_vt_shgc": 1.1, "annotation": "Entrance door" @@ -68030,10 +78770,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.42, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -68049,10 +78792,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.54, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.23, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -68068,10 +78814,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.68, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.23, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -68087,10 +78836,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Fixed" @@ -68106,10 +78858,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Fixed" @@ -68125,10 +78880,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Entrance door" @@ -68144,10 +78902,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68163,10 +78924,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68182,10 +78946,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68201,10 +78968,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.6, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -68220,10 +78990,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.6, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -68239,10 +79012,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68258,10 +79034,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68277,10 +79056,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.86, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68296,10 +79078,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.54, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68315,10 +79100,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.86, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68334,10 +79122,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68353,10 +79144,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68372,10 +79166,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68391,10 +79188,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68410,10 +79210,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68429,10 +79232,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68448,10 +79254,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.3, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68467,10 +79276,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.3, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68486,10 +79298,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68505,10 +79320,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.3, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68524,10 +79342,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.3, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68543,10 +79364,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68562,10 +79386,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.3, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68581,10 +79408,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.55, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.3, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68600,10 +79430,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68619,10 +79452,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -68638,10 +79474,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -68657,10 +79496,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -68676,10 +79518,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -68695,10 +79540,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -68714,10 +79562,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -68733,10 +79584,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.057, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68752,10 +79606,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68771,10 +79628,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68790,10 +79650,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68809,10 +79672,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68828,10 +79694,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68847,10 +79716,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.107, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68866,10 +79738,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68885,10 +79760,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68904,10 +79782,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68923,10 +79804,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68942,10 +79826,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.037, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68961,10 +79848,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.021, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68980,10 +79870,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -68999,10 +79892,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.037, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69018,10 +79914,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.021, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69037,10 +79936,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.093, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69056,10 +79958,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.082, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69075,10 +79980,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.034, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69094,10 +80002,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69113,10 +80024,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.104, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69132,10 +80046,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.06, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69151,10 +80068,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69170,10 +80090,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69189,10 +80112,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.09, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69208,10 +80134,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.05, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69227,10 +80156,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69246,10 +80178,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69265,10 +80200,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69284,10 +80222,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.162, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69303,10 +80244,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69322,10 +80266,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69341,10 +80288,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69360,10 +80310,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -69379,10 +80332,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -69398,10 +80354,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -69417,10 +80376,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -69436,10 +80398,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.63, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.33, "assembly_minimum_vt_shgc": 1.1, "annotation": "Entrance door" @@ -69455,10 +80420,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -69474,10 +80442,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.33, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -69493,10 +80464,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.63, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.33, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -69512,10 +80486,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Fixed" @@ -69531,10 +80508,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Fixed" @@ -69550,10 +80530,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Entrance door" @@ -69569,10 +80552,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69588,10 +80574,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69607,10 +80596,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69626,10 +80618,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.63, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.33, "assembly_minimum_vt_shgc": 1.1, "annotation": "Entrance door" @@ -69645,10 +80640,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -69664,10 +80662,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.33, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -69683,10 +80684,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.63, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.33, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -69702,10 +80706,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -69721,10 +80728,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -69740,10 +80750,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.81, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69759,10 +80772,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.52, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69778,10 +80794,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.843, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69797,10 +80816,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.52, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69816,10 +80838,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.688, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69835,10 +80860,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69854,10 +80882,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.9, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69873,10 +80904,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69892,10 +80926,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69911,10 +80948,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.092, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69930,10 +80970,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69949,10 +80992,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69968,10 +81014,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -69987,10 +81036,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70006,10 +81058,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70025,10 +81080,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70044,10 +81102,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70063,10 +81124,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70082,10 +81146,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70101,10 +81168,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70120,10 +81190,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -70139,10 +81212,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -70158,10 +81234,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -70177,10 +81256,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -70196,10 +81278,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -70215,10 +81300,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -70234,10 +81322,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.057, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70253,10 +81344,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70272,10 +81366,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70291,10 +81388,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70310,10 +81410,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70329,10 +81432,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70348,10 +81454,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.107, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70367,10 +81476,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70386,10 +81498,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70405,10 +81520,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70424,10 +81542,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70443,10 +81564,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.037, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70462,10 +81586,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.021, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70481,10 +81608,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70500,10 +81630,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.037, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70519,10 +81652,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.021, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70538,10 +81674,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70557,10 +81696,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.082, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70576,10 +81718,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.034, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70595,10 +81740,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70614,10 +81762,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.09, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70633,10 +81784,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.05, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70652,10 +81806,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.055, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70671,10 +81828,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70690,10 +81850,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.08, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70709,10 +81872,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.05, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70728,10 +81894,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.055, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70747,10 +81916,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70766,10 +81938,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70785,10 +81960,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.094, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70804,10 +81982,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.084, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70823,10 +82004,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70842,10 +82026,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -70861,10 +82048,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.38, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -70880,10 +82070,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.38, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -70899,10 +82092,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.38, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -70918,10 +82114,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.38, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -70937,10 +82136,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.63, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.33, "assembly_minimum_vt_shgc": 1.1, "annotation": "Entrance door" @@ -70956,10 +82158,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.38, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -70975,10 +82180,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.33, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -70994,10 +82202,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.63, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.33, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -71013,10 +82224,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Fixed" @@ -71032,10 +82246,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Fixed" @@ -71051,10 +82268,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Entrance door" @@ -71070,10 +82290,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71089,10 +82312,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71108,10 +82334,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.77, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71127,10 +82356,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.63, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.33, "assembly_minimum_vt_shgc": 1.1, "annotation": "Entrance door" @@ -71146,10 +82378,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.38, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -71165,10 +82400,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.33, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -71184,10 +82422,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.63, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.33, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -71203,10 +82444,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -71222,10 +82466,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -71241,10 +82488,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71260,10 +82510,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.52, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71279,10 +82532,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.688, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71298,10 +82554,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.51, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71317,10 +82576,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.688, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71336,10 +82598,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71355,10 +82620,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.9, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71374,10 +82642,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71393,10 +82664,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71412,10 +82686,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.092, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71431,10 +82708,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71450,10 +82730,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71469,10 +82752,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71488,10 +82774,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71507,10 +82796,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71526,10 +82818,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71545,10 +82840,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71564,10 +82862,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71583,10 +82884,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71602,10 +82906,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71621,10 +82928,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -71640,10 +82950,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -71659,10 +82972,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -71678,10 +82994,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -71697,10 +83016,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -71716,10 +83038,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -71735,10 +83060,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71754,10 +83082,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71773,10 +83104,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71792,10 +83126,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71811,10 +83148,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71830,10 +83170,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71849,10 +83192,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.087, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71868,10 +83214,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71887,10 +83236,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71906,10 +83258,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71925,10 +83280,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71944,10 +83302,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.031, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71963,10 +83324,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.021, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -71982,10 +83346,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72001,10 +83368,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.029, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72020,10 +83390,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.021, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72039,10 +83412,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72058,10 +83434,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.06, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72077,10 +83456,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.034, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72096,10 +83478,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72115,10 +83500,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.08, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72134,10 +83522,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.05, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72153,10 +83544,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.049, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72172,10 +83566,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72191,10 +83588,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.071, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72210,10 +83610,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.05, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72229,10 +83632,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.049, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72248,10 +83654,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72267,10 +83676,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72286,10 +83698,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.094, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72305,10 +83720,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.084, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72324,10 +83742,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72343,10 +83764,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72362,10 +83786,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.34, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.38, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -72381,10 +83808,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.34, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.38, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -72400,10 +83830,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.63, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.34, "assembly_minimum_vt_shgc": 1.1, "annotation": "Entrance door" @@ -72419,10 +83852,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.34, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.38, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -72438,10 +83874,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.42, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.34, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -72457,10 +83896,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.63, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.34, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -72476,10 +83918,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.34, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.38, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -72495,10 +83940,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.34, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.38, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -72514,10 +83962,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.63, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.34, "assembly_minimum_vt_shgc": 1.1, "annotation": "Entrance door" @@ -72533,10 +83984,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.34, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.38, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -72552,10 +84006,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.42, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.34, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -72571,10 +84028,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.63, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.34, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -72590,10 +84050,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.39, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Fixed" @@ -72609,10 +84072,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.39, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Fixed" @@ -72628,10 +84094,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.68, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Entrance door" @@ -72647,10 +84116,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.39, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72666,10 +84138,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.48, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72685,10 +84160,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.68, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72704,10 +84182,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -72723,10 +84204,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -72742,10 +84226,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.59, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72761,10 +84248,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.51, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72780,10 +84270,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.688, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72799,10 +84292,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.434, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72818,10 +84314,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.671, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72837,10 +84336,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72856,10 +84358,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.86, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72875,10 +84380,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72894,10 +84402,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.092, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72913,10 +84424,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.063, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72932,10 +84446,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72951,10 +84468,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.47, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72970,10 +84490,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -72989,10 +84512,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73008,10 +84534,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.47, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73027,10 +84556,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73046,10 +84578,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73065,10 +84600,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.47, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73084,10 +84622,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73103,10 +84644,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73122,10 +84666,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -73141,10 +84688,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -73160,10 +84710,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -73179,10 +84732,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -73198,10 +84754,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -73217,10 +84776,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -73236,10 +84798,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.042, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73255,10 +84820,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73274,10 +84842,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73293,10 +84864,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.042, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73312,10 +84886,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73331,10 +84908,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.27, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73350,10 +84930,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.074, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73369,10 +84952,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73388,10 +84974,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73407,10 +84996,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73426,10 +85018,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.028, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73445,10 +85040,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.029, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73464,10 +85062,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.017, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73483,10 +85084,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.028, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73502,10 +85106,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.029, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73521,10 +85128,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.017, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73540,10 +85150,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73559,10 +85172,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.037, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73578,10 +85194,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73597,10 +85216,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73616,10 +85238,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.071, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73635,10 +85260,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.044, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73654,10 +85282,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.049, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73673,10 +85304,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73692,10 +85326,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.071, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73711,10 +85348,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.044, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73730,10 +85370,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.042, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73749,10 +85392,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73768,10 +85414,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.123, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73787,10 +85436,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.072, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73806,10 +85458,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73825,10 +85480,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73844,10 +85502,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -73863,10 +85524,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.29, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -73882,10 +85546,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.29, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -73901,10 +85568,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.63, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": 1.1, "annotation": "Entrance door" @@ -73920,10 +85590,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.29, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -73939,10 +85612,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -73958,10 +85634,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.63, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -73977,10 +85656,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.29, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -73996,10 +85678,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.29, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -74015,10 +85700,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.63, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": 1.1, "annotation": "Entrance door" @@ -74034,10 +85722,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.26, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -74053,10 +85744,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -74072,10 +85766,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.63, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -74091,10 +85788,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Fixed" @@ -74110,10 +85810,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Fixed" @@ -74129,10 +85832,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.63, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Entrance door" @@ -74148,10 +85854,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74167,10 +85876,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.44, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74186,10 +85898,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.63, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74205,10 +85920,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.4, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -74224,10 +85942,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.4, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -74243,10 +85964,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.44, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74262,10 +85986,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.51, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74281,10 +86008,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.671, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74300,10 +86030,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.434, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74319,10 +86052,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.671, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74338,10 +86074,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74357,10 +86096,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.86, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74376,10 +86118,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74395,10 +86140,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.063, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74414,10 +86162,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.063, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74433,10 +86184,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74452,10 +86206,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.44, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74471,10 +86228,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.44, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74490,10 +86250,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74509,10 +86272,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.44, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74528,10 +86294,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.44, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74547,10 +86316,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74566,10 +86338,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.44, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74585,10 +86360,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.44, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74604,10 +86382,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74623,10 +86404,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -74642,10 +86426,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -74661,10 +86448,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -74680,10 +86470,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -74699,10 +86492,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -74718,10 +86514,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -74737,10 +86536,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74756,10 +86558,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74775,10 +86580,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74794,10 +86602,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.038, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74813,10 +86624,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74832,10 +86646,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74851,10 +86668,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74870,10 +86690,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.052, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74889,10 +86712,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74908,10 +86734,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74927,10 +86756,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.028, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74946,10 +86778,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.026, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74965,10 +86800,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.017, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -74984,10 +86822,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.028, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75003,10 +86844,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.026, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75022,10 +86866,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.017, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75041,10 +86888,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75060,10 +86910,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.037, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75079,10 +86932,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75098,10 +86954,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75117,10 +86976,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75136,10 +86998,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75155,10 +87020,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.037, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75174,10 +87042,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75193,10 +87064,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75212,10 +87086,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75231,10 +87108,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.037, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75250,10 +87130,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75269,10 +87152,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.104, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75288,10 +87174,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.06, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75307,10 +87196,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.064, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75326,10 +87218,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.051, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75345,10 +87240,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75364,10 +87262,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.26, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -75383,10 +87284,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.26, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -75402,10 +87306,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.63, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": 1.1, "annotation": "Entrance door" @@ -75421,10 +87328,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.26, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -75440,10 +87350,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.32, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -75459,10 +87372,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.63, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -75478,10 +87394,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.26, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -75497,10 +87416,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.26, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -75516,10 +87438,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.63, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": 1.1, "annotation": "Entrance door" @@ -75535,10 +87460,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.26, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.4, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -75554,10 +87482,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.32, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -75573,10 +87504,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.63, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -75592,10 +87526,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Fixed" @@ -75611,10 +87548,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Fixed" @@ -75630,10 +87570,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.63, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Entrance door" @@ -75649,10 +87592,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75668,10 +87614,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.44, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75687,10 +87636,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.63, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75706,10 +87658,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.4, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -75725,10 +87680,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.4, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.45, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -75744,10 +87702,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.44, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75763,10 +87724,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.434, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75782,10 +87746,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.671, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75801,10 +87768,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.424, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75820,10 +87790,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.373, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75839,10 +87812,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.54, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75858,10 +87834,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.86, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75877,10 +87856,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75896,10 +87878,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.063, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75915,10 +87900,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.063, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75934,10 +87922,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 0.119, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75953,10 +87944,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.41, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75972,10 +87966,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.41, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -75991,10 +87988,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76010,10 +88010,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.41, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76029,10 +88032,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.41, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76048,10 +88054,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76067,10 +88076,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.41, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76086,10 +88098,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.41, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76105,10 +88120,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76124,10 +88142,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76143,10 +88164,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76162,10 +88186,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.094, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76181,10 +88208,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76200,10 +88230,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76219,10 +88252,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76238,10 +88274,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.352, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76257,10 +88296,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.352, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76276,10 +88318,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.292, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76295,10 +88340,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76314,10 +88362,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.23, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -76333,10 +88384,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.23, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -76352,10 +88406,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.83, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.21, "assembly_minimum_vt_shgc": 1.1, "annotation": "Entrance door" @@ -76371,10 +88428,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.23, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -76390,10 +88450,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.62, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.21, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -76409,10 +88472,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.83, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.21, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -76428,10 +88494,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.23, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -76447,10 +88516,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.23, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -76466,10 +88538,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.83, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.21, "assembly_minimum_vt_shgc": 1.1, "annotation": "Entrance door" @@ -76485,10 +88560,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.23, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -76504,10 +88582,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.62, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.21, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -76523,10 +88604,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.83, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.21, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -76542,10 +88626,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Fixed" @@ -76561,10 +88648,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Fixed" @@ -76580,10 +88670,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.1, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Entrance door" @@ -76599,10 +88692,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76618,10 +88714,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76637,10 +88736,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.1, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76656,10 +88758,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -76675,10 +88780,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -76694,10 +88802,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76713,10 +88824,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76732,10 +88846,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76751,10 +88868,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76770,10 +88890,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76789,10 +88912,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76808,10 +88934,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76827,10 +88956,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76846,10 +88978,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76865,10 +89000,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76884,10 +89022,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76903,10 +89044,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.3, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76922,10 +89066,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.3, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76941,10 +89088,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.55, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76960,10 +89110,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.3, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76979,10 +89132,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.3, "assembly_minimum_vt_shgc": null, "annotation": null @@ -76998,10 +89154,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.55, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77017,10 +89176,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.3, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77036,10 +89198,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.3, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77055,10 +89220,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.55, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77074,10 +89242,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -77093,10 +89264,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -77112,10 +89286,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -77131,10 +89308,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -77150,10 +89330,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77169,10 +89352,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77188,10 +89374,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77207,10 +89396,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77226,10 +89418,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77245,10 +89440,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77264,10 +89462,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77283,10 +89484,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77302,10 +89506,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77321,10 +89528,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77340,10 +89550,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77359,10 +89572,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77378,10 +89594,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77397,10 +89616,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.041, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77416,10 +89638,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77435,10 +89660,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77454,10 +89682,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.041, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77473,10 +89704,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77492,10 +89726,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.218, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77511,10 +89748,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.115, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77530,10 +89770,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.081, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77549,10 +89792,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77568,10 +89814,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77587,10 +89836,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.094, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77606,10 +89858,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77625,10 +89880,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77644,10 +89902,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77663,10 +89924,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.094, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77682,10 +89946,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77701,10 +89968,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77720,10 +89990,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77739,10 +90012,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.352, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77758,10 +90034,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.352, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77777,10 +90056,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.292, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77796,10 +90078,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77815,10 +90100,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.32, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.22, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -77834,10 +90122,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.22, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -77853,10 +90144,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.83, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.22, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -77872,10 +90166,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.32, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.22, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -77891,10 +90188,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.22, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -77910,10 +90210,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.83, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.22, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -77929,10 +90232,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.93, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77948,10 +90254,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77967,10 +90276,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.1, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -77986,10 +90298,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -78005,10 +90320,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -78024,10 +90342,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78043,10 +90364,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78062,10 +90386,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78081,10 +90408,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78100,10 +90430,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78119,10 +90452,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78138,10 +90474,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78157,10 +90496,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78176,10 +90518,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78195,10 +90540,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78214,10 +90562,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78233,10 +90584,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.35, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78252,10 +90606,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.35, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78271,10 +90628,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.55, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78290,10 +90650,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.35, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78309,10 +90672,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.35, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78328,10 +90694,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.55, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78347,10 +90716,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.35, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78366,10 +90738,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.35, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78385,10 +90760,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.55, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78404,10 +90782,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -78423,10 +90804,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -78442,10 +90826,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.37, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -78461,10 +90848,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.31, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Exceptions 1. and 2. from Section 5.5.3.6 is not captured in this table" @@ -78480,10 +90870,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78499,10 +90892,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78518,10 +90914,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78537,10 +90936,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78556,10 +90958,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78575,10 +90980,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78594,10 +91002,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78613,10 +91024,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78632,10 +91046,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78651,10 +91068,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78670,10 +91090,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78689,10 +91112,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78708,10 +91134,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78727,10 +91156,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.041, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78746,10 +91178,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78765,10 +91200,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.032, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78784,10 +91222,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.041, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78803,10 +91244,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78822,10 +91266,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.218, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78841,10 +91288,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.115, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78860,10 +91310,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.081, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78879,10 +91332,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78898,10 +91354,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78917,10 +91376,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.094, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78936,10 +91398,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78955,10 +91420,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78974,10 +91442,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -78993,10 +91464,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.094, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79012,10 +91486,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79031,10 +91508,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79050,10 +91530,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79069,10 +91552,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.352, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79088,10 +91574,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.352, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79107,10 +91596,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.292, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79126,10 +91618,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79145,10 +91640,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.22, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -79164,10 +91662,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.22, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -79183,10 +91684,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.83, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.2, "assembly_minimum_vt_shgc": 1.1, "annotation": "Entrance door" @@ -79202,10 +91706,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.22, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -79221,10 +91728,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.62, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.2, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -79240,10 +91750,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.83, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.2, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -79259,10 +91772,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.22, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -79278,10 +91794,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.22, "assembly_minimum_vt_shgc": 1.1, "annotation": "Fixed" @@ -79297,10 +91816,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.83, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.2, "assembly_minimum_vt_shgc": 1.1, "annotation": "Entrance door" @@ -79316,10 +91838,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.22, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -79335,10 +91860,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.62, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.2, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -79354,10 +91882,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.83, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.2, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -79373,10 +91904,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Fixed" @@ -79392,10 +91926,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Fixed" @@ -79411,10 +91948,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.1, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": "Entrance door" @@ -79430,10 +91970,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79449,10 +91992,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79468,10 +92014,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.1, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79487,10 +92036,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -79506,10 +92058,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -79525,10 +92080,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79544,10 +92102,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79563,10 +92124,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79582,10 +92146,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79601,10 +92168,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79620,10 +92190,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79639,10 +92212,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79658,10 +92234,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79677,10 +92256,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79696,10 +92278,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79715,10 +92300,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79734,10 +92322,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.3, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79753,10 +92344,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.3, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79772,10 +92366,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79791,10 +92388,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.3, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79810,10 +92410,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.3, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79829,10 +92432,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79848,10 +92454,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.3, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79867,10 +92476,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.3, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79886,10 +92498,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79905,10 +92520,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79924,10 +92542,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79943,10 +92564,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79962,10 +92586,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -79981,10 +92608,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80000,10 +92630,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80019,10 +92652,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80038,10 +92674,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80057,10 +92696,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80076,10 +92718,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80095,10 +92740,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80114,10 +92762,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80133,10 +92784,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80152,10 +92806,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80171,10 +92828,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80190,10 +92850,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80209,10 +92872,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80228,10 +92894,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80247,10 +92916,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.034, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80266,10 +92938,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80285,10 +92960,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80304,10 +92982,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80323,10 +93004,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.614, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80342,10 +93026,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80361,10 +93048,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.28, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80380,10 +93070,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80399,10 +93092,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80418,10 +93114,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80437,10 +93136,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80456,10 +93158,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80475,10 +93180,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80494,10 +93202,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80513,10 +93224,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80532,10 +93246,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80551,10 +93268,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80570,10 +93290,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.18, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80589,10 +93312,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.352, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80608,10 +93334,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.292, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80627,10 +93356,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80646,10 +93378,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80665,10 +93400,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80684,10 +93422,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80703,10 +93444,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80722,10 +93466,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80741,10 +93488,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80760,10 +93510,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80779,10 +93532,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80798,10 +93554,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80817,10 +93576,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80836,10 +93598,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80855,10 +93620,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80874,10 +93642,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80893,10 +93664,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80912,10 +93686,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80931,10 +93708,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80950,10 +93730,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80969,10 +93752,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -80988,10 +93774,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81007,10 +93796,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81026,10 +93818,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81045,10 +93840,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81064,10 +93862,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81083,10 +93884,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81102,10 +93906,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81121,10 +93928,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81140,10 +93950,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81159,10 +93972,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81178,10 +93994,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81197,10 +94016,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81216,10 +94038,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81235,10 +94060,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81254,10 +94082,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81273,10 +94104,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81292,10 +94126,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81311,10 +94148,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81330,10 +94170,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81349,10 +94192,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81368,10 +94214,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81387,10 +94236,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81406,10 +94258,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81425,10 +94280,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81444,10 +94302,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81463,10 +94324,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81482,10 +94346,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81501,10 +94368,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81520,10 +94390,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81539,10 +94412,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81558,10 +94434,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81577,10 +94456,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81596,10 +94478,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81615,10 +94500,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81634,10 +94522,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81653,10 +94544,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81672,10 +94566,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81691,10 +94588,13 @@ "minimum_percent_of_surface": 1, "maximum_percent_of_surface": 10, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81710,10 +94610,13 @@ "minimum_percent_of_surface": 10.001, "maximum_percent_of_surface": 20, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81729,10 +94632,13 @@ "minimum_percent_of_surface": 20.001, "maximum_percent_of_surface": 30, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81748,10 +94654,13 @@ "minimum_percent_of_surface": 30.001, "maximum_percent_of_surface": 40, "assembly_maximum_u_value": 1.22, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81767,10 +94676,13 @@ "minimum_percent_of_surface": 40.001, "maximum_percent_of_surface": 100, "assembly_maximum_u_value": 0.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81786,10 +94698,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81805,10 +94720,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81824,10 +94742,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81843,10 +94764,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81862,10 +94786,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81881,10 +94808,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81900,10 +94830,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81919,10 +94852,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81938,10 +94874,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81957,10 +94896,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81976,10 +94918,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -81995,10 +94940,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82014,10 +94962,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.16, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82033,10 +94984,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82052,10 +95006,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82071,10 +95028,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.34, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82090,10 +95050,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.27, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82109,10 +95072,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.27, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82128,10 +95094,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82147,10 +95116,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82166,10 +95138,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82185,10 +95160,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82204,10 +95182,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82223,10 +95204,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82242,10 +95226,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82261,10 +95248,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82280,10 +95270,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82299,10 +95292,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82318,10 +95314,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82337,10 +95336,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82356,10 +95358,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82375,10 +95380,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82394,10 +95402,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82413,10 +95424,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82432,10 +95446,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82451,10 +95468,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82470,10 +95490,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82489,10 +95512,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.034, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82508,10 +95534,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82527,10 +95556,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82546,10 +95578,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.218, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82565,10 +95600,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.081, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82584,10 +95622,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82603,10 +95644,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.28, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82622,10 +95666,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82641,10 +95688,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82660,10 +95710,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82679,10 +95732,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82698,10 +95754,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82717,10 +95776,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82736,10 +95798,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82755,10 +95820,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82774,10 +95842,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82793,10 +95864,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82812,10 +95886,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.18, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82831,10 +95908,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.352, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82850,10 +95930,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.292, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82869,10 +95952,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82888,10 +95974,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82907,10 +95996,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82926,10 +96018,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82945,10 +96040,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82964,10 +96062,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -82983,10 +96084,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83002,10 +96106,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83021,10 +96128,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83040,10 +96150,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83059,10 +96172,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83078,10 +96194,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83097,10 +96216,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83116,10 +96238,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83135,10 +96260,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83154,10 +96282,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83173,10 +96304,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83192,10 +96326,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83211,10 +96348,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83230,10 +96370,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83249,10 +96392,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83268,10 +96414,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83287,10 +96436,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83306,10 +96458,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83325,10 +96480,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83344,10 +96502,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83363,10 +96524,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83382,10 +96546,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83401,10 +96568,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.77, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83420,10 +96590,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.77, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83439,10 +96612,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.62, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83458,10 +96634,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83477,10 +96656,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83496,10 +96678,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83515,10 +96700,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83534,10 +96722,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83553,10 +96744,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83572,10 +96766,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83591,10 +96788,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83610,10 +96810,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83629,10 +96832,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83648,10 +96854,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83667,10 +96876,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83686,10 +96898,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.033, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83705,10 +96920,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83724,10 +96942,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83743,10 +96964,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83762,10 +96986,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83781,10 +97008,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83800,10 +97030,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.063, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83819,10 +97052,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.034, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83838,10 +97074,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83857,10 +97096,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83876,10 +97118,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.065, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83895,10 +97140,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.218, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83914,10 +97162,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.081, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83933,10 +97184,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.167, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83952,10 +97206,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83971,10 +97228,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -83990,10 +97250,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.093, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84009,10 +97272,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84028,10 +97294,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84047,10 +97316,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84066,10 +97338,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.093, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84085,10 +97360,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84104,10 +97382,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84123,10 +97404,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84142,10 +97426,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.113, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84161,10 +97448,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.352, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84180,10 +97470,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.292, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84199,10 +97492,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84218,10 +97514,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84237,10 +97536,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84256,10 +97558,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84275,10 +97580,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84294,10 +97602,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84313,10 +97624,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84332,10 +97646,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84351,10 +97668,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84370,10 +97690,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84389,10 +97712,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84408,10 +97734,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84427,10 +97756,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84446,10 +97778,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84465,10 +97800,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84484,10 +97822,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84503,10 +97844,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84522,10 +97866,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84541,10 +97888,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84560,10 +97910,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84579,10 +97932,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84598,10 +97954,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84617,10 +97976,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84636,10 +97998,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84655,10 +98020,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84674,10 +98042,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.98, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84693,10 +98064,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.36, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84712,10 +98086,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84731,10 +98108,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.9, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.19, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84750,10 +98130,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84769,10 +98152,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84788,10 +98174,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.36, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84807,10 +98196,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84826,10 +98218,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84845,10 +98240,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84864,10 +98262,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84883,10 +98284,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.7, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84902,10 +98306,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.45, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84921,10 +98328,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84940,10 +98350,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84959,10 +98372,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84978,10 +98394,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -84997,10 +98416,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85016,10 +98438,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85035,10 +98460,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.322, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85054,10 +98482,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.35, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85073,10 +98504,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.282, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85092,10 +98526,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85111,10 +98548,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.048, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85130,10 +98570,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.041, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85149,10 +98592,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85168,10 +98614,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.039, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85187,10 +98636,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.041, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85206,10 +98658,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.027, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85225,10 +98680,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.218, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85244,10 +98702,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.1156, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85263,10 +98724,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.081, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85282,10 +98746,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85301,10 +98768,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85320,10 +98790,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.094, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85339,10 +98812,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85358,10 +98834,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85377,10 +98856,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.151, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85396,10 +98878,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.094, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85415,10 +98900,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.124, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85434,10 +98922,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.089, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85453,10 +98944,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.58, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85472,10 +98966,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.352, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85491,10 +98988,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.352, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85510,10 +99010,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.292, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85529,10 +99032,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85548,10 +99054,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -85567,10 +99076,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -85586,10 +99098,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.1, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -85605,10 +99120,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.5, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -85624,10 +99142,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.57, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -85643,10 +99164,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.1, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -85662,10 +99186,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.93, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85681,10 +99208,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85700,10 +99230,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.1, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85719,10 +99252,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -85738,10 +99274,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 0.65, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": 1.1, "annotation": null @@ -85757,10 +99296,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": 1.2, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.25, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85776,10 +99318,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85795,10 +99340,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85814,10 +99362,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85833,10 +99384,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85852,10 +99406,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 0.73, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85871,10 +99428,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": 1.02, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85890,10 +99450,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": 0, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": null, "u_value_includes_exterior_film_coefficient": null, "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85909,10 +99472,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85928,10 +99494,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85947,10 +99516,13 @@ "minimum_percent_of_surface": null, "maximum_percent_of_surface": null, "assembly_maximum_u_value": null, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": 1.14, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85966,10 +99538,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -85985,10 +99560,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -86004,10 +99582,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.49, "assembly_minimum_vt_shgc": null, "annotation": null @@ -86023,10 +99604,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.39, "assembly_minimum_vt_shgc": null, "annotation": null @@ -86042,10 +99626,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -86061,10 +99648,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": null, "assembly_minimum_vt_shgc": null, "annotation": null @@ -86080,10 +99670,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.68, "assembly_minimum_vt_shgc": null, "annotation": null @@ -86099,10 +99692,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 0.75, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.64, "assembly_minimum_vt_shgc": null, "annotation": null @@ -86118,10 +99714,13 @@ "minimum_percent_of_surface": 0, "maximum_percent_of_surface": 2, "assembly_maximum_u_value": 1.8, + "assembly_maximum_u_value_unit": "Btu/h-ft2-F", "u_value_includes_interior_film_coefficient": "TRUE", "u_value_includes_exterior_film_coefficient": "TRUE", "assembly_maximum_f_factor": null, + "assembly_maximum_f_factor_unit": "Btu-in/h-ft2-F", "assembly_maximum_c_factor": null, + "assembly_maximum_c_factor_unit": "Btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.64, "assembly_minimum_vt_shgc": null, "annotation": null diff --git a/data/openstudio_standards_data/database_files/level_2_natural_gas_equipment.json b/data/openstudio_standards_data/database_files/level_2_natural_gas_equipment.json index aef2798e52..add5846ac4 100644 --- a/data/openstudio_standards_data/database_files/level_2_natural_gas_equipment.json +++ b/data/openstudio_standards_data/database_files/level_2_natural_gas_equipment.json @@ -5,7 +5,7 @@ "natural_gas_equipment_average_epd": 361.7807576, "natural_gas_equipment_median_epd": 302.6, "natural_gas_equipment_maximum_epd": 767, - "natural_gas_equipment_epd_unit": "Btu/hr.ft2", + "natural_gas_equipment_epd_unit": "Btu/h-ft2", "natural_gas_equipment_fraction_latent": 0.1, "natural_gas_equipment_fraction_radiant": 0.2, "natural_gas_equipment_fraction_lost": 0.7 @@ -16,7 +16,7 @@ "natural_gas_equipment_average_epd": 138.4291667, "natural_gas_equipment_median_epd": 129.9, "natural_gas_equipment_maximum_epd": 170, - "natural_gas_equipment_epd_unit": "Btu/hr.ft2", + "natural_gas_equipment_epd_unit": "Btu/h-ft2", "natural_gas_equipment_fraction_latent": 0, "natural_gas_equipment_fraction_radiant": 0.5, "natural_gas_equipment_fraction_lost": 0 @@ -27,7 +27,7 @@ "natural_gas_equipment_average_epd": 23.223, "natural_gas_equipment_median_epd": 23.87, "natural_gas_equipment_maximum_epd": 23.87, - "natural_gas_equipment_epd_unit": "Btu/hr.ft2", + "natural_gas_equipment_epd_unit": "Btu/h-ft2", "natural_gas_equipment_fraction_latent": 0, "natural_gas_equipment_fraction_radiant": 0, "natural_gas_equipment_fraction_lost": 0.5 @@ -38,7 +38,7 @@ "natural_gas_equipment_average_epd": 8.5225, "natural_gas_equipment_median_epd": 8.52, "natural_gas_equipment_maximum_epd": 8.53, - "natural_gas_equipment_epd_unit": "Btu/hr.ft2", + "natural_gas_equipment_epd_unit": "Btu/h-ft2", "natural_gas_equipment_fraction_latent": 0.1, "natural_gas_equipment_fraction_radiant": 0.2, "natural_gas_equipment_fraction_lost": 0.7 @@ -49,7 +49,7 @@ "natural_gas_equipment_average_epd": 8.5375, "natural_gas_equipment_median_epd": 8.54, "natural_gas_equipment_maximum_epd": 8.54, - "natural_gas_equipment_epd_unit": "Btu/hr.ft2", + "natural_gas_equipment_epd_unit": "Btu/h-ft2", "natural_gas_equipment_fraction_latent": 0.1, "natural_gas_equipment_fraction_radiant": 0.2, "natural_gas_equipment_fraction_lost": 0.7 @@ -60,7 +60,7 @@ "natural_gas_equipment_average_epd": 6.25, "natural_gas_equipment_median_epd": 6.25, "natural_gas_equipment_maximum_epd": 6.25, - "natural_gas_equipment_epd_unit": "Btu/hr.ft2", + "natural_gas_equipment_epd_unit": "Btu/h-ft2", "natural_gas_equipment_fraction_latent": 0.1, "natural_gas_equipment_fraction_radiant": 0.2, "natural_gas_equipment_fraction_lost": 0.7 diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2004.json b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2004.json index bc5e80c1fa..6edfe37c24 100644 --- a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2004.json +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2004.json @@ -4,7 +4,7 @@ "lighting_primary_space_type": "Automotive Facility", "lighting_secondary_space_type": "General", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -18,7 +18,7 @@ "lighting_primary_space_type": "Convention Center", "lighting_secondary_space_type": "General", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -32,7 +32,7 @@ "lighting_primary_space_type": "Court House", "lighting_secondary_space_type": "General", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -46,7 +46,7 @@ "lighting_primary_space_type": "Dining: Bar Lounge/Leisure", "lighting_secondary_space_type": "General", "lighting_power_density": 1.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -60,7 +60,7 @@ "lighting_primary_space_type": "Dining: Cafeteria/Fast Food", "lighting_secondary_space_type": "General", "lighting_power_density": 1.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -74,7 +74,7 @@ "lighting_primary_space_type": "Dining: Family", "lighting_secondary_space_type": "General", "lighting_power_density": 1.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -88,7 +88,7 @@ "lighting_primary_space_type": "Dormitory", "lighting_secondary_space_type": "General", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -102,7 +102,7 @@ "lighting_primary_space_type": "Exercise Center", "lighting_secondary_space_type": "General", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -116,7 +116,7 @@ "lighting_primary_space_type": "Gymnasium", "lighting_secondary_space_type": "General", "lighting_power_density": 1.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -130,7 +130,7 @@ "lighting_primary_space_type": "Health Care-Clinic", "lighting_secondary_space_type": "General", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -144,7 +144,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "General", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -158,7 +158,7 @@ "lighting_primary_space_type": "Hotel", "lighting_secondary_space_type": "General", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -172,7 +172,7 @@ "lighting_primary_space_type": "Library", "lighting_secondary_space_type": "General", "lighting_power_density": 1.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -186,7 +186,7 @@ "lighting_primary_space_type": "Manufacturing Facility", "lighting_secondary_space_type": "General", "lighting_power_density": 1.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -200,7 +200,7 @@ "lighting_primary_space_type": "Motel", "lighting_secondary_space_type": "General", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -214,7 +214,7 @@ "lighting_primary_space_type": "Motion Picture Theater", "lighting_secondary_space_type": "General", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -228,7 +228,7 @@ "lighting_primary_space_type": "Multi-Family", "lighting_secondary_space_type": "General", "lighting_power_density": 0.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -242,7 +242,7 @@ "lighting_primary_space_type": "Museum", "lighting_secondary_space_type": "General", "lighting_power_density": 1.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -256,7 +256,7 @@ "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "General", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -270,7 +270,7 @@ "lighting_primary_space_type": "Parking Garage", "lighting_secondary_space_type": "General", "lighting_power_density": 0.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -284,7 +284,7 @@ "lighting_primary_space_type": "Penitentiary", "lighting_secondary_space_type": "General", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -298,7 +298,7 @@ "lighting_primary_space_type": "Performing Arts Theater", "lighting_secondary_space_type": "General", "lighting_power_density": 1.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -312,7 +312,7 @@ "lighting_primary_space_type": "Police/Fire Station", "lighting_secondary_space_type": "General", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -326,7 +326,7 @@ "lighting_primary_space_type": "Post Office", "lighting_secondary_space_type": "General", "lighting_power_density": 1.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -340,7 +340,7 @@ "lighting_primary_space_type": "Religious Building", "lighting_secondary_space_type": "General", "lighting_power_density": 1.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -354,7 +354,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "General", "lighting_power_density": 1.5, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -368,7 +368,7 @@ "lighting_primary_space_type": "School/University", "lighting_secondary_space_type": "General", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -382,7 +382,7 @@ "lighting_primary_space_type": "Sports Arena", "lighting_secondary_space_type": "General", "lighting_power_density": 1.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -396,7 +396,7 @@ "lighting_primary_space_type": "Town Hall", "lighting_secondary_space_type": "General", "lighting_power_density": 1.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -410,7 +410,7 @@ "lighting_primary_space_type": "Transportation", "lighting_secondary_space_type": "General", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -424,7 +424,7 @@ "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "General", "lighting_power_density": 0.8, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -438,7 +438,7 @@ "lighting_primary_space_type": "Workshop", "lighting_secondary_space_type": "General", "lighting_power_density": 1.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -452,7 +452,7 @@ "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_power_density": 1.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -466,7 +466,7 @@ "lighting_primary_space_type": "Office-Open Plan", "lighting_secondary_space_type": "General", "lighting_power_density": 1.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -480,7 +480,7 @@ "lighting_primary_space_type": "Conference/Meeting/Multipurpose", "lighting_secondary_space_type": "General", "lighting_power_density": 1.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -494,7 +494,7 @@ "lighting_primary_space_type": "Classroom/Lecture/Training", "lighting_secondary_space_type": "General", "lighting_power_density": 1.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -508,7 +508,7 @@ "lighting_primary_space_type": "Classroom/Lecture/Training", "lighting_secondary_space_type": "For Penitentiary", "lighting_power_density": 1.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -522,7 +522,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_power_density": 1.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -536,7 +536,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "For Hotel", "lighting_power_density": 1.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -550,7 +550,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "For Performing Arts Theater", "lighting_power_density": 3.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -564,7 +564,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "For Motion Picture Theater", "lighting_power_density": 1.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -578,7 +578,7 @@ "lighting_primary_space_type": "Audience/Seating Area", "lighting_secondary_space_type": "General", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -592,7 +592,7 @@ "lighting_primary_space_type": "Audience/Seating Area", "lighting_secondary_space_type": "For Gymnasium", "lighting_power_density": 0.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -606,7 +606,7 @@ "lighting_primary_space_type": "Audience/Seating Area", "lighting_secondary_space_type": "For Exercise Center", "lighting_power_density": 0.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -620,7 +620,7 @@ "lighting_primary_space_type": "Audience/Seating Area", "lighting_secondary_space_type": "For Convention Center", "lighting_power_density": 0.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -634,7 +634,7 @@ "lighting_primary_space_type": "Audience/Seating Area", "lighting_secondary_space_type": "For Penitentiary", "lighting_power_density": 0.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -648,7 +648,7 @@ "lighting_primary_space_type": "Audience/Seating Area", "lighting_secondary_space_type": "For Religious Buildings", "lighting_power_density": 1.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -662,7 +662,7 @@ "lighting_primary_space_type": "Audience/Seating Area", "lighting_secondary_space_type": "For Sports Arena", "lighting_power_density": 0.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -676,7 +676,7 @@ "lighting_primary_space_type": "Audience/Seating Area", "lighting_secondary_space_type": "For Performing Arts Theater", "lighting_power_density": 2.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -690,7 +690,7 @@ "lighting_primary_space_type": "Audience/Seating Area", "lighting_secondary_space_type": "For Motion Picture Theater", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -704,7 +704,7 @@ "lighting_primary_space_type": "Audience/Seating Area", "lighting_secondary_space_type": "For Transportation", "lighting_power_density": 0.5, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -718,7 +718,7 @@ "lighting_primary_space_type": "Atrium: First Three Floors", "lighting_secondary_space_type": "General", "lighting_power_density": 0.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -732,7 +732,7 @@ "lighting_primary_space_type": "Atrium: Each Additional Floor", "lighting_secondary_space_type": "General", "lighting_power_density": 0.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -746,7 +746,7 @@ "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "General", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -760,7 +760,7 @@ "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "For Hospital", "lighting_power_density": 0.8, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -774,7 +774,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -788,7 +788,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Penitentiary", "lighting_power_density": 1.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -802,7 +802,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Hotel", "lighting_power_density": 1.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -816,7 +816,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Motel", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -830,7 +830,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Bar Lounge/Leisure Dining", "lighting_power_density": 1.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -844,7 +844,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Family Dining", "lighting_power_density": 2.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -858,7 +858,7 @@ "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -872,7 +872,7 @@ "lighting_primary_space_type": "Laboratory", "lighting_secondary_space_type": "General", "lighting_power_density": 1.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -886,7 +886,7 @@ "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -900,7 +900,7 @@ "lighting_primary_space_type": "Dressing/Locker/Fitting Room", "lighting_secondary_space_type": "General", "lighting_power_density": 0.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -914,7 +914,7 @@ "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_power_density": 0.5, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -928,7 +928,7 @@ "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "For Hospital", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -942,7 +942,7 @@ "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "For Manufacturing Facility", "lighting_power_density": 0.5, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -956,7 +956,7 @@ "lighting_primary_space_type": "Stairs: Active", "lighting_secondary_space_type": "General", "lighting_power_density": 0.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -970,7 +970,7 @@ "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "General", "lighting_power_density": 0.8, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -984,7 +984,7 @@ "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "For Hospital", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -998,7 +998,7 @@ "lighting_primary_space_type": "Inactive Storage", "lighting_secondary_space_type": "General", "lighting_power_density": 0.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1012,7 +1012,7 @@ "lighting_primary_space_type": "Inactive Storage", "lighting_secondary_space_type": "For Museum", "lighting_power_density": 0.8, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1026,7 +1026,7 @@ "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_power_density": 1.5, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1040,7 +1040,7 @@ "lighting_primary_space_type": "Workshop", "lighting_secondary_space_type": "General", "lighting_power_density": 1.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1054,7 +1054,7 @@ "lighting_primary_space_type": "Gymnasium/Exercise Center", "lighting_secondary_space_type": "Playing Area", "lighting_power_density": 1.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1068,7 +1068,7 @@ "lighting_primary_space_type": "Gymnasium/Exercise Center", "lighting_secondary_space_type": "Exercise Area", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1082,7 +1082,7 @@ "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", "lighting_secondary_space_type": "Courtroom", "lighting_power_density": 1.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1096,7 +1096,7 @@ "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", "lighting_secondary_space_type": "Confinement Cells", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1110,7 +1110,7 @@ "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", "lighting_secondary_space_type": "Judges Chambers", "lighting_power_density": 1.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1124,7 +1124,7 @@ "lighting_primary_space_type": "Fire Stations", "lighting_secondary_space_type": "Fire Station Engine Room", "lighting_power_density": 0.8, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1138,7 +1138,7 @@ "lighting_primary_space_type": "Fire Stations", "lighting_secondary_space_type": "Sleeping Quarters", "lighting_power_density": 0.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1152,7 +1152,7 @@ "lighting_primary_space_type": "Post Office: Sorting Area", "lighting_secondary_space_type": "General", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1166,7 +1166,7 @@ "lighting_primary_space_type": "Convention Center: Exhibit Space", "lighting_secondary_space_type": "General", "lighting_power_density": 1.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1180,7 +1180,7 @@ "lighting_primary_space_type": "Library", "lighting_secondary_space_type": "Card File and Cataloging", "lighting_power_density": 1.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1194,7 +1194,7 @@ "lighting_primary_space_type": "Library", "lighting_secondary_space_type": "Stacks", "lighting_power_density": 1.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1208,7 +1208,7 @@ "lighting_primary_space_type": "Library", "lighting_secondary_space_type": "Reading Area", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1222,7 +1222,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Emergency", "lighting_power_density": 2.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1236,7 +1236,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Recovery", "lighting_power_density": 0.8, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1250,7 +1250,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Nurse Station", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1264,7 +1264,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Exam/Treatment", "lighting_power_density": 1.5, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1278,7 +1278,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Pharmacy", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1292,7 +1292,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Patient Room", "lighting_power_density": 0.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1306,7 +1306,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Operating Room", "lighting_power_density": 2.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1320,7 +1320,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Nursery", "lighting_power_density": 0.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1334,7 +1334,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Medical Supply", "lighting_power_density": 1.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1348,7 +1348,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Physical Therapy", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1362,7 +1362,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Radiology", "lighting_power_density": 0.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1376,7 +1376,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Laundry: Washing", "lighting_power_density": 0.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1390,7 +1390,7 @@ "lighting_primary_space_type": "Automotive: Service/Repair", "lighting_secondary_space_type": "General", "lighting_power_density": 0.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1404,7 +1404,7 @@ "lighting_primary_space_type": "Manufacturing", "lighting_secondary_space_type": "Low Bay (<25 ft Floor to Ceiling Height)", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1418,7 +1418,7 @@ "lighting_primary_space_type": "Manufacturing", "lighting_secondary_space_type": "High Bay (>25 ft Floor to Ceiling Height)", "lighting_power_density": 1.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1432,7 +1432,7 @@ "lighting_primary_space_type": "Manufacturing", "lighting_secondary_space_type": "Detailed Manufacturing", "lighting_power_density": 2.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1446,7 +1446,7 @@ "lighting_primary_space_type": "Manufacturing", "lighting_secondary_space_type": "Equipment Room", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1460,7 +1460,7 @@ "lighting_primary_space_type": "Manufacturing", "lighting_secondary_space_type": "Control Room", "lighting_power_density": 0.5, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1474,7 +1474,7 @@ "lighting_primary_space_type": "Hotel/Motel Guest Rooms", "lighting_secondary_space_type": "General", "lighting_power_density": 1.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1488,7 +1488,7 @@ "lighting_primary_space_type": "Dormitory: Living Quarters", "lighting_secondary_space_type": "General", "lighting_power_density": 1.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1502,7 +1502,7 @@ "lighting_primary_space_type": "Museum", "lighting_secondary_space_type": "General Exhibition", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1516,7 +1516,7 @@ "lighting_primary_space_type": "Museum", "lighting_secondary_space_type": "Restoration", "lighting_power_density": 1.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1530,7 +1530,7 @@ "lighting_primary_space_type": "Bank/Office Banking Activity Area", "lighting_secondary_space_type": "General", "lighting_power_density": 1.5, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1544,7 +1544,7 @@ "lighting_primary_space_type": "Religious Buildings", "lighting_secondary_space_type": "Worship Pulpit, Choir", "lighting_power_density": 2.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1558,7 +1558,7 @@ "lighting_primary_space_type": "Religious Buildings", "lighting_secondary_space_type": "Fellowship Hall", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1572,7 +1572,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Sales Area", "lighting_power_density": 1.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1586,7 +1586,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Mall Concourse", "lighting_power_density": 1.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1600,7 +1600,7 @@ "lighting_primary_space_type": "Sports Arena", "lighting_secondary_space_type": "Ring Sports Area", "lighting_power_density": 2.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1614,7 +1614,7 @@ "lighting_primary_space_type": "Sports Arena", "lighting_secondary_space_type": "Court Sports Area", "lighting_power_density": 2.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1628,7 +1628,7 @@ "lighting_primary_space_type": "Sports Arena", "lighting_secondary_space_type": "Indoor Playing Field Area", "lighting_power_density": 1.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1642,7 +1642,7 @@ "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "Fine Material Storage", "lighting_power_density": 1.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1656,7 +1656,7 @@ "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "Medium/Bulky Material Storage", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1670,7 +1670,7 @@ "lighting_primary_space_type": "Parking Garage: Garage Area", "lighting_secondary_space_type": "General", "lighting_power_density": 0.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1684,7 +1684,7 @@ "lighting_primary_space_type": "Transportation", "lighting_secondary_space_type": "Airport: Concourse", "lighting_power_density": 0.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1698,7 +1698,7 @@ "lighting_primary_space_type": "Transportation", "lighting_secondary_space_type": "Air/Train/Bus: Baggage Area", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1712,7 +1712,7 @@ "lighting_primary_space_type": "Transportation", "lighting_secondary_space_type": "Terminal: Ticket Counter", "lighting_power_density": 1.5, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1726,7 +1726,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Sales Additional (Specific Display)", "lighting_power_density": 1.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1740,7 +1740,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Sales Additional (Valuable Merchandise)", "lighting_power_density": 3.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1754,7 +1754,7 @@ "lighting_primary_space_type": "None", "lighting_secondary_space_type": "None", "lighting_power_density": 0, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2007.json b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2007.json index 9181f5184c..49ca9bb4a7 100644 --- a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2007.json +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2007.json @@ -4,7 +4,7 @@ "lighting_primary_space_type": "Automotive Facility", "lighting_secondary_space_type": "General", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -18,7 +18,7 @@ "lighting_primary_space_type": "Convention Center", "lighting_secondary_space_type": "General", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -32,7 +32,7 @@ "lighting_primary_space_type": "Courthouse", "lighting_secondary_space_type": "General", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -46,7 +46,7 @@ "lighting_primary_space_type": "Dining: Bar Lounge/leisure", "lighting_secondary_space_type": "General", "lighting_power_density": 1.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -60,7 +60,7 @@ "lighting_primary_space_type": "Dining: Cafeteria/fast Food", "lighting_secondary_space_type": "General", "lighting_power_density": 1.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -74,7 +74,7 @@ "lighting_primary_space_type": "Dining: Family", "lighting_secondary_space_type": "General", "lighting_power_density": 1.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -88,7 +88,7 @@ "lighting_primary_space_type": "Dormitory", "lighting_secondary_space_type": "General", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -102,7 +102,7 @@ "lighting_primary_space_type": "Exercise Center", "lighting_secondary_space_type": "General", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -116,7 +116,7 @@ "lighting_primary_space_type": "Gymnasium", "lighting_secondary_space_type": "General", "lighting_power_density": 1.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -130,7 +130,7 @@ "lighting_primary_space_type": "Health-care Clinic", "lighting_secondary_space_type": "General", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -144,7 +144,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "General", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -158,7 +158,7 @@ "lighting_primary_space_type": "Hotel", "lighting_secondary_space_type": "General", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -172,7 +172,7 @@ "lighting_primary_space_type": "Library", "lighting_secondary_space_type": "General", "lighting_power_density": 1.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -186,7 +186,7 @@ "lighting_primary_space_type": "Manufacturing Facility", "lighting_secondary_space_type": "General", "lighting_power_density": 1.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -200,7 +200,7 @@ "lighting_primary_space_type": "Motel", "lighting_secondary_space_type": "General", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -214,7 +214,7 @@ "lighting_primary_space_type": "Motion Picture Theater", "lighting_secondary_space_type": "General", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -228,7 +228,7 @@ "lighting_primary_space_type": "Multifamily", "lighting_secondary_space_type": "General", "lighting_power_density": 0.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -242,7 +242,7 @@ "lighting_primary_space_type": "Museum", "lighting_secondary_space_type": "General", "lighting_power_density": 1.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -256,7 +256,7 @@ "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "General", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -270,7 +270,7 @@ "lighting_primary_space_type": "Parking Garage", "lighting_secondary_space_type": "General", "lighting_power_density": 0.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -284,7 +284,7 @@ "lighting_primary_space_type": "Penitentiary", "lighting_secondary_space_type": "General", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -298,7 +298,7 @@ "lighting_primary_space_type": "Performing Arts Theater", "lighting_secondary_space_type": "General", "lighting_power_density": 1.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -312,7 +312,7 @@ "lighting_primary_space_type": "Police/fire Station", "lighting_secondary_space_type": "General", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -326,7 +326,7 @@ "lighting_primary_space_type": "Post Office", "lighting_secondary_space_type": "General", "lighting_power_density": 1.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -340,7 +340,7 @@ "lighting_primary_space_type": "Religious Building", "lighting_secondary_space_type": "General", "lighting_power_density": 1.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -354,7 +354,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "General", "lighting_power_density": 1.5, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -368,7 +368,7 @@ "lighting_primary_space_type": "School/University", "lighting_secondary_space_type": "General", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -382,7 +382,7 @@ "lighting_primary_space_type": "Sports Arena", "lighting_secondary_space_type": "General", "lighting_power_density": 1.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -396,7 +396,7 @@ "lighting_primary_space_type": "Town Hall", "lighting_secondary_space_type": "General", "lighting_power_density": 1.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -410,7 +410,7 @@ "lighting_primary_space_type": "Transportation", "lighting_secondary_space_type": "General", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -424,7 +424,7 @@ "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "General", "lighting_power_density": 0.8, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -438,7 +438,7 @@ "lighting_primary_space_type": "Workshop", "lighting_secondary_space_type": "General", "lighting_power_density": 1.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -452,7 +452,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Bar Lounge/Leisure Dining", "lighting_power_density": 1.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -466,7 +466,7 @@ "lighting_primary_space_type": "Audience/seating Area", "lighting_secondary_space_type": "For Convention Center", "lighting_power_density": 0.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -480,7 +480,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Family Dining", "lighting_power_density": 2.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -494,7 +494,7 @@ "lighting_primary_space_type": "Audience/seating Area", "lighting_secondary_space_type": "For Exercise Center", "lighting_power_density": 0.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -508,7 +508,7 @@ "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "For Hospital", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -522,7 +522,7 @@ "lighting_primary_space_type": "Corridor/transition", "lighting_secondary_space_type": "For Hospital", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -536,7 +536,7 @@ "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "For Hospital", "lighting_power_density": 0.8, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -550,7 +550,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Hotel", "lighting_power_density": 1.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -564,7 +564,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "For Hotel", "lighting_power_density": 1.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -578,7 +578,7 @@ "lighting_primary_space_type": "Corridor/transition", "lighting_secondary_space_type": "For Manufacturing Facility", "lighting_power_density": 0.5, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -592,7 +592,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Motel", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -606,7 +606,7 @@ "lighting_primary_space_type": "Audience/seating Area", "lighting_secondary_space_type": "General", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -620,7 +620,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "For Motion Picture Theater", "lighting_power_density": 1.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -634,7 +634,7 @@ "lighting_primary_space_type": "Inactive Storage", "lighting_secondary_space_type": "For Museum", "lighting_power_density": 0.8, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -648,7 +648,7 @@ "lighting_primary_space_type": "Classroom/Lecture/Training", "lighting_secondary_space_type": "For Penitentiary", "lighting_power_density": 1.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -662,7 +662,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Penitentiary", "lighting_power_density": 1.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -676,7 +676,7 @@ "lighting_primary_space_type": "Audience/seating Area", "lighting_secondary_space_type": "For Gymnasium", "lighting_power_density": 0.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -690,7 +690,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "For Performing Arts Theater", "lighting_power_density": 3.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -704,7 +704,7 @@ "lighting_primary_space_type": "Audience/seating Area", "lighting_secondary_space_type": "For Motion Picture Theater", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -718,7 +718,7 @@ "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "General", "lighting_power_density": 0.8, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -732,7 +732,7 @@ "lighting_primary_space_type": "Atrium each Additional Floor", "lighting_secondary_space_type": "General", "lighting_power_density": 0.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -746,7 +746,7 @@ "lighting_primary_space_type": "Atrium first Three Floors", "lighting_secondary_space_type": "General", "lighting_power_density": 0.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -760,7 +760,7 @@ "lighting_primary_space_type": "Classroom/Lecture/Training", "lighting_secondary_space_type": "General", "lighting_power_density": 1.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -774,7 +774,7 @@ "lighting_primary_space_type": "Conference/Meeting/Multipurpose", "lighting_secondary_space_type": "General", "lighting_power_density": 1.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -788,7 +788,7 @@ "lighting_primary_space_type": "Corridor/transition", "lighting_secondary_space_type": "General", "lighting_power_density": 0.5, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -802,7 +802,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -816,7 +816,7 @@ "lighting_primary_space_type": "Dressing/Locker/Fitting Room", "lighting_secondary_space_type": "General", "lighting_power_density": 0.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -830,7 +830,7 @@ "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_power_density": 1.5, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -844,7 +844,7 @@ "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -858,7 +858,7 @@ "lighting_primary_space_type": "Inactive Storage", "lighting_secondary_space_type": "General", "lighting_power_density": 0.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -872,7 +872,7 @@ "lighting_primary_space_type": "Laboratory", "lighting_secondary_space_type": "General", "lighting_power_density": 1.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -886,7 +886,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_power_density": 1.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -900,7 +900,7 @@ "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "General", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -914,7 +914,7 @@ "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_power_density": 1.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -928,7 +928,7 @@ "lighting_primary_space_type": "Office-Open Plan", "lighting_secondary_space_type": "General", "lighting_power_density": 1.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -942,7 +942,7 @@ "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -956,7 +956,7 @@ "lighting_primary_space_type": "Sales Area", "lighting_secondary_space_type": "General", "lighting_power_density": 1.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -970,7 +970,7 @@ "lighting_primary_space_type": "Audience/seating Area", "lighting_secondary_space_type": "For Penitentiary", "lighting_power_density": 0.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -984,7 +984,7 @@ "lighting_primary_space_type": "Stairs active", "lighting_secondary_space_type": "General", "lighting_power_density": 0.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -998,7 +998,7 @@ "lighting_primary_space_type": "Workshop", "lighting_secondary_space_type": "General", "lighting_power_density": 1.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1012,7 +1012,7 @@ "lighting_primary_space_type": "Audience/seating Area", "lighting_secondary_space_type": "For Performing Arts Theater", "lighting_power_density": 2.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1026,7 +1026,7 @@ "lighting_primary_space_type": "Audience/seating Area", "lighting_secondary_space_type": "For Religious Buildings", "lighting_power_density": 1.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1040,7 +1040,7 @@ "lighting_primary_space_type": "Audience/seating Area", "lighting_secondary_space_type": "For Sports Arena", "lighting_power_density": 0.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1054,7 +1054,7 @@ "lighting_primary_space_type": "Audience/seating Area", "lighting_secondary_space_type": "For Transportation", "lighting_power_density": 0.5, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1068,7 +1068,7 @@ "lighting_primary_space_type": "Transportation", "lighting_secondary_space_type": "Air/Train/Bus Baggage Area", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1082,7 +1082,7 @@ "lighting_primary_space_type": "Transportation", "lighting_secondary_space_type": "Airport Concourse", "lighting_power_density": 0.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1096,7 +1096,7 @@ "lighting_primary_space_type": "Library", "lighting_secondary_space_type": "Card File and Cataloging", "lighting_power_density": 1.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1110,7 +1110,7 @@ "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", "lighting_secondary_space_type": "Confinement Cells", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1124,7 +1124,7 @@ "lighting_primary_space_type": "Manufacturing", "lighting_secondary_space_type": "Control Room", "lighting_power_density": 0.5, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1138,7 +1138,7 @@ "lighting_primary_space_type": "Sports Arena", "lighting_secondary_space_type": "Court Sports Area", "lighting_power_density": 2.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1152,7 +1152,7 @@ "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", "lighting_secondary_space_type": "Courtroom", "lighting_power_density": 1.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1166,7 +1166,7 @@ "lighting_primary_space_type": "Manufacturing", "lighting_secondary_space_type": "Detailed Manufacturing", "lighting_power_density": 2.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1180,7 +1180,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Emergency", "lighting_power_density": 2.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1194,7 +1194,7 @@ "lighting_primary_space_type": "Fire Stations", "lighting_secondary_space_type": "Engine Room", "lighting_power_density": 0.8, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1208,7 +1208,7 @@ "lighting_primary_space_type": "Manufacturing", "lighting_secondary_space_type": "Equipment Room", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1222,7 +1222,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Exam/Treatment", "lighting_power_density": 1.5, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1236,7 +1236,7 @@ "lighting_primary_space_type": "Gymnasium/exercise Center", "lighting_secondary_space_type": "Exercise Area", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1250,7 +1250,7 @@ "lighting_primary_space_type": "Religious Buildings", "lighting_secondary_space_type": "Fellowship Hall", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1264,7 +1264,7 @@ "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "Fine Material Storage", "lighting_power_density": 1.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1278,7 +1278,7 @@ "lighting_primary_space_type": "Automotive service/repair", "lighting_secondary_space_type": "General", "lighting_power_density": 0.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1292,7 +1292,7 @@ "lighting_primary_space_type": "Bank/Office Banking Activity Area", "lighting_secondary_space_type": "General", "lighting_power_density": 1.5, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1306,7 +1306,7 @@ "lighting_primary_space_type": "Convention Center exhibit Space", "lighting_secondary_space_type": "General", "lighting_power_density": 1.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1320,7 +1320,7 @@ "lighting_primary_space_type": "Dormitory living Quarters", "lighting_secondary_space_type": "General", "lighting_power_density": 1.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1334,7 +1334,7 @@ "lighting_primary_space_type": "Hotel/motel Guest Rooms", "lighting_secondary_space_type": "General", "lighting_power_density": 1.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1348,7 +1348,7 @@ "lighting_primary_space_type": "Parking Garage garage Area", "lighting_secondary_space_type": "General", "lighting_power_density": 0.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1362,7 +1362,7 @@ "lighting_primary_space_type": "Post Office sorting Area", "lighting_secondary_space_type": "General", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1376,7 +1376,7 @@ "lighting_primary_space_type": "Museum", "lighting_secondary_space_type": "General Exhibition", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1390,7 +1390,7 @@ "lighting_primary_space_type": "Manufacturing", "lighting_secondary_space_type": "High Bay (>25 ft Floor to Ceiling Height)", "lighting_power_density": 1.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1404,7 +1404,7 @@ "lighting_primary_space_type": "Sports Arena", "lighting_secondary_space_type": "Indoor Playing Field Area", "lighting_power_density": 1.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1418,7 +1418,7 @@ "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", "lighting_secondary_space_type": "Judges Chambers", "lighting_power_density": 1.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1432,7 +1432,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Laundry Washing", "lighting_power_density": 0.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1446,7 +1446,7 @@ "lighting_primary_space_type": "Manufacturing", "lighting_secondary_space_type": "Low Bay (<25 ft Floor to Ceiling Height)", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1460,7 +1460,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Mall Concourse", "lighting_power_density": 1.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1474,7 +1474,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Medical Supply", "lighting_power_density": 1.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1488,7 +1488,7 @@ "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "Medium/Bulky Material Storage", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1502,7 +1502,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Nurse Station", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1516,7 +1516,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Nursery", "lighting_power_density": 0.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1530,7 +1530,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Operating Room", "lighting_power_density": 2.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1544,7 +1544,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Patient Room", "lighting_power_density": 0.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1558,7 +1558,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Pharmacy", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1572,7 +1572,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Physical Therapy", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1586,7 +1586,7 @@ "lighting_primary_space_type": "Gymnasium/exercise Center", "lighting_secondary_space_type": "Playing Area", "lighting_power_density": 1.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1600,7 +1600,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Radiology", "lighting_power_density": 0.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1614,7 +1614,7 @@ "lighting_primary_space_type": "Library", "lighting_secondary_space_type": "Reading Area", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1628,7 +1628,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Recovery", "lighting_power_density": 0.8, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1642,7 +1642,7 @@ "lighting_primary_space_type": "Museum", "lighting_secondary_space_type": "Restoration", "lighting_power_density": 1.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1656,7 +1656,7 @@ "lighting_primary_space_type": "Sports Arena", "lighting_secondary_space_type": "Ring Sports Area", "lighting_power_density": 2.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1670,7 +1670,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Sales Additional (Type 1)", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1684,7 +1684,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Sales Additional (Type 2)", "lighting_power_density": 1.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1698,7 +1698,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Sales Additional (Type 3)", "lighting_power_density": 2.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1712,7 +1712,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Sales Additional (Type 4)", "lighting_power_density": 4.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1726,7 +1726,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Sales Area", "lighting_power_density": 1.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1740,7 +1740,7 @@ "lighting_primary_space_type": "Fire Stations", "lighting_secondary_space_type": "Sleeping Quarters", "lighting_power_density": 0.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1754,7 +1754,7 @@ "lighting_primary_space_type": "Library", "lighting_secondary_space_type": "Stacks", "lighting_power_density": 1.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1768,7 +1768,7 @@ "lighting_primary_space_type": "Transportation", "lighting_secondary_space_type": "Terminal Ticket Counter", "lighting_power_density": 1.5, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1782,7 +1782,7 @@ "lighting_primary_space_type": "Religious Buildings", "lighting_secondary_space_type": "Worship Pulpit, Choir", "lighting_power_density": 2.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1796,7 +1796,7 @@ "lighting_primary_space_type": "None", "lighting_secondary_space_type": "None", "lighting_power_density": 0, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2010.json b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2010.json index f3650018cd..848cefc4fd 100644 --- a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2010.json +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2010.json @@ -4,7 +4,7 @@ "lighting_primary_space_type": "Automotive Facility", "lighting_secondary_space_type": "General", "lighting_power_density": 0.82, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -18,7 +18,7 @@ "lighting_primary_space_type": "Convention Center", "lighting_secondary_space_type": "General", "lighting_power_density": 1.08, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -32,7 +32,7 @@ "lighting_primary_space_type": "Courthouse", "lighting_secondary_space_type": "General", "lighting_power_density": 1.05, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -46,7 +46,7 @@ "lighting_primary_space_type": "Dining: Bar Lounge/Leisure", "lighting_secondary_space_type": "General", "lighting_power_density": 0.99, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -60,7 +60,7 @@ "lighting_primary_space_type": "Dining: Cafeteria/Fast Food", "lighting_secondary_space_type": "General", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -74,7 +74,7 @@ "lighting_primary_space_type": "Dining: Family", "lighting_secondary_space_type": "General", "lighting_power_density": 0.89, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -88,7 +88,7 @@ "lighting_primary_space_type": "Dormitory", "lighting_secondary_space_type": "General", "lighting_power_density": 0.61, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -102,7 +102,7 @@ "lighting_primary_space_type": "Exercise Center", "lighting_secondary_space_type": "General", "lighting_power_density": 0.88, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -116,7 +116,7 @@ "lighting_primary_space_type": "Fire Stations", "lighting_secondary_space_type": "General", "lighting_power_density": 0.71, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -130,7 +130,7 @@ "lighting_primary_space_type": "Gymnasium", "lighting_secondary_space_type": "General", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -144,7 +144,7 @@ "lighting_primary_space_type": "Health-care Clinic", "lighting_secondary_space_type": "General", "lighting_power_density": 0.87, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -158,7 +158,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "General", "lighting_power_density": 1.21, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -172,7 +172,7 @@ "lighting_primary_space_type": "Hotel", "lighting_secondary_space_type": "General", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -186,7 +186,7 @@ "lighting_primary_space_type": "Library", "lighting_secondary_space_type": "General", "lighting_power_density": 1.18, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -200,7 +200,7 @@ "lighting_primary_space_type": "Manufacturing Facility", "lighting_secondary_space_type": "General", "lighting_power_density": 1.11, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -214,7 +214,7 @@ "lighting_primary_space_type": "Motel", "lighting_secondary_space_type": "General", "lighting_power_density": 0.88, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -228,7 +228,7 @@ "lighting_primary_space_type": "Motion Picture Theater", "lighting_secondary_space_type": "General", "lighting_power_density": 0.83, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -242,7 +242,7 @@ "lighting_primary_space_type": "Multifamily", "lighting_secondary_space_type": "General", "lighting_power_density": 0.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -256,7 +256,7 @@ "lighting_primary_space_type": "Museum", "lighting_secondary_space_type": "General", "lighting_power_density": 1.06, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -270,7 +270,7 @@ "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "General", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -284,7 +284,7 @@ "lighting_primary_space_type": "Parking Garage", "lighting_secondary_space_type": "General", "lighting_power_density": 0.25, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -298,7 +298,7 @@ "lighting_primary_space_type": "Penitentiary", "lighting_secondary_space_type": "General", "lighting_power_density": 0.97, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -312,7 +312,7 @@ "lighting_primary_space_type": "Performing Arts Theater", "lighting_secondary_space_type": "General", "lighting_power_density": 1.39, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -326,7 +326,7 @@ "lighting_primary_space_type": "Police Station", "lighting_secondary_space_type": "General", "lighting_power_density": 0.96, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -340,7 +340,7 @@ "lighting_primary_space_type": "Post Office", "lighting_secondary_space_type": "General", "lighting_power_density": 0.87, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -354,7 +354,7 @@ "lighting_primary_space_type": "Religious Building", "lighting_secondary_space_type": "General", "lighting_power_density": 1.05, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -368,7 +368,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "General", "lighting_power_density": 1.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -382,7 +382,7 @@ "lighting_primary_space_type": "School/University", "lighting_secondary_space_type": "General", "lighting_power_density": 0.99, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -396,7 +396,7 @@ "lighting_primary_space_type": "Sports Arena", "lighting_secondary_space_type": "General", "lighting_power_density": 0.78, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -410,7 +410,7 @@ "lighting_primary_space_type": "Town Hall", "lighting_secondary_space_type": "General", "lighting_power_density": 0.92, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -424,7 +424,7 @@ "lighting_primary_space_type": "Transportation", "lighting_secondary_space_type": "General", "lighting_power_density": 0.77, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -438,7 +438,7 @@ "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "General", "lighting_power_density": 0.66, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -452,7 +452,7 @@ "lighting_primary_space_type": "Workshop", "lighting_secondary_space_type": "General", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -466,7 +466,7 @@ "lighting_primary_space_type": "Audience/seating Area permanent", "lighting_secondary_space_type": "For auditorium", "lighting_power_density": 0.79, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -480,7 +480,7 @@ "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "Enclosed", "lighting_power_density": 1.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -494,7 +494,7 @@ "lighting_primary_space_type": "Atrium", "lighting_secondary_space_type": "First 40 ft in height", "lighting_power_density": 0.03, - "unit": "W/ft", + "lighting_power_density_unit": "W/ft", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -508,7 +508,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Bar Lounge/Leisure Dining", "lighting_power_density": 1.31, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -522,7 +522,7 @@ "lighting_primary_space_type": "Laboratory", "lighting_secondary_space_type": "For Classrooms", "lighting_power_density": 1.28, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -536,7 +536,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "For Elevator", "lighting_power_density": 0.64, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -550,7 +550,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Family Dining", "lighting_power_density": 0.89, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -564,7 +564,7 @@ "lighting_primary_space_type": "Laboratory", "lighting_secondary_space_type": "For Medical/Industrial/Research", "lighting_power_density": 1.81, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -578,7 +578,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "For Motion Picture Theater", "lighting_power_density": 0.52, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -592,7 +592,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "For Performing Arts Theater", "lighting_power_density": 2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -606,7 +606,7 @@ "lighting_primary_space_type": "Audience/seating Area permanent", "lighting_secondary_space_type": "For Motion Picture Theater", "lighting_power_density": 1.14, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -620,7 +620,7 @@ "lighting_primary_space_type": "Classroom/Lecture/Training", "lighting_secondary_space_type": "General", "lighting_power_density": 1.24, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -634,7 +634,7 @@ "lighting_primary_space_type": "Conference/Meeting/Multipurpose", "lighting_secondary_space_type": "General", "lighting_power_density": 1.23, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -648,7 +648,7 @@ "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_power_density": 0.66, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -662,7 +662,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_power_density": 0.65, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -676,7 +676,7 @@ "lighting_primary_space_type": "Dressing/Fitting Room For Performing Arts Theater", "lighting_secondary_space_type": "General", "lighting_power_density": 0.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -690,7 +690,7 @@ "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_power_density": 0.95, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -704,7 +704,7 @@ "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_power_density": 0.99, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -718,7 +718,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -732,7 +732,7 @@ "lighting_primary_space_type": "Locker Room", "lighting_secondary_space_type": "General", "lighting_power_density": 0.75, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -746,7 +746,7 @@ "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "General", "lighting_power_density": 0.73, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -760,7 +760,7 @@ "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_power_density": 0.98, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -774,7 +774,7 @@ "lighting_primary_space_type": "Sales Area", "lighting_secondary_space_type": "General", "lighting_power_density": 1.68, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -788,7 +788,7 @@ "lighting_primary_space_type": "Stairway", "lighting_secondary_space_type": "General", "lighting_power_density": 0.69, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 10, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -802,7 +802,7 @@ "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_power_density": 0.63, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -816,7 +816,7 @@ "lighting_primary_space_type": "Workshop", "lighting_secondary_space_type": "General", "lighting_power_density": 1.59, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -830,7 +830,7 @@ "lighting_primary_space_type": "Atrium", "lighting_secondary_space_type": "Height above 40 ft", "lighting_power_density": 0.02, - "unit": "W/ft", + "lighting_power_density_unit": "W/ft", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -844,7 +844,7 @@ "lighting_primary_space_type": "Audience/seating Area permanent", "lighting_secondary_space_type": "For Performing Arts Theater", "lighting_power_density": 2.43, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -858,7 +858,7 @@ "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "Open Plan", "lighting_power_density": 0.98, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -872,7 +872,7 @@ "lighting_primary_space_type": "Transportation", "lighting_secondary_space_type": "Air/Train/Bus Baggage Area", "lighting_power_density": 0.76, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -886,7 +886,7 @@ "lighting_primary_space_type": "Transportation", "lighting_secondary_space_type": "Airport Concourse", "lighting_power_density": 0.36, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -900,7 +900,7 @@ "lighting_primary_space_type": "Convention Center", "lighting_secondary_space_type": "Audience Seating", "lighting_power_density": 0.82, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -914,7 +914,7 @@ "lighting_primary_space_type": "Religious Buildings", "lighting_secondary_space_type": "Audience Seating", "lighting_power_density": 1.53, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -928,7 +928,7 @@ "lighting_primary_space_type": "Sports Arena", "lighting_secondary_space_type": "Audience Seating", "lighting_power_density": 0.43, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -942,7 +942,7 @@ "lighting_primary_space_type": "Transportation", "lighting_secondary_space_type": "Audience Seating", "lighting_power_density": 0.54, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -956,7 +956,7 @@ "lighting_primary_space_type": "Bank/Office", "lighting_secondary_space_type": "Banking Activity Area", "lighting_power_density": 1.38, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -970,7 +970,7 @@ "lighting_primary_space_type": "Library", "lighting_secondary_space_type": "Card File and Cataloging", "lighting_power_density": 0.72, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -984,7 +984,7 @@ "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", "lighting_secondary_space_type": "Confinement Cells", "lighting_power_density": 1.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -998,7 +998,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Corridor/Transition", "lighting_power_density": 0.89, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1012,7 +1012,7 @@ "lighting_primary_space_type": "Manufacturing", "lighting_secondary_space_type": "Corridor/Transition", "lighting_power_density": 0.41, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1026,7 +1026,7 @@ "lighting_primary_space_type": "Sports Arena", "lighting_secondary_space_type": "Court Sports Arena Class 1", "lighting_power_density": 3.01, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1040,7 +1040,7 @@ "lighting_primary_space_type": "Sports Arena", "lighting_secondary_space_type": "Court Sports Arena Class 2", "lighting_power_density": 1.92, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1054,7 +1054,7 @@ "lighting_primary_space_type": "Sports Arena", "lighting_secondary_space_type": "Court Sports Arena Class 3", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1068,7 +1068,7 @@ "lighting_primary_space_type": "Sports Arena", "lighting_secondary_space_type": "Court Sports Arena Class 4", "lighting_power_density": 0.72, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1082,7 +1082,7 @@ "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", "lighting_secondary_space_type": "Courtroom", "lighting_power_density": 1.72, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1096,7 +1096,7 @@ "lighting_primary_space_type": "Manufacturing", "lighting_secondary_space_type": "Detailed Manufacturing", "lighting_power_density": 1.29, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1110,7 +1110,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Dressing/Fitting Room", "lighting_power_density": 0.87, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1124,7 +1124,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Emergency", "lighting_power_density": 2.26, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1138,7 +1138,7 @@ "lighting_primary_space_type": "Fire Stations", "lighting_secondary_space_type": "Engine Room", "lighting_power_density": 0.56, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1152,7 +1152,7 @@ "lighting_primary_space_type": "Manufacturing", "lighting_secondary_space_type": "Equipment Room", "lighting_power_density": 0.95, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1166,7 +1166,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Exam/Treatment", "lighting_power_density": 1.66, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1180,7 +1180,7 @@ "lighting_primary_space_type": "Gymnasium/fitness Center", "lighting_secondary_space_type": "Exercise Area", "lighting_power_density": 0.72, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1194,7 +1194,7 @@ "lighting_primary_space_type": "Convention Center", "lighting_secondary_space_type": "Exhibit Space", "lighting_power_density": 1.45, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1208,7 +1208,7 @@ "lighting_primary_space_type": "Manufacturing", "lighting_secondary_space_type": "Extra High Bay (>50 ft Floor to Ceiling Height)", "lighting_power_density": 1.05, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1222,7 +1222,7 @@ "lighting_primary_space_type": "Religious Buildings", "lighting_secondary_space_type": "Fellowship Hall", "lighting_power_density": 0.64, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1236,7 +1236,7 @@ "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "Fine Material Storage", "lighting_power_density": 0.95, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1250,7 +1250,7 @@ "lighting_primary_space_type": "Parking Garage", "lighting_secondary_space_type": "Garage Area", "lighting_power_density": 0.19, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1264,7 +1264,7 @@ "lighting_primary_space_type": "Post Office Sorting Area", "lighting_secondary_space_type": "General", "lighting_power_density": 0.94, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1278,7 +1278,7 @@ "lighting_primary_space_type": "Museum", "lighting_secondary_space_type": "General Exhibition", "lighting_power_density": 1.05, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1292,7 +1292,7 @@ "lighting_primary_space_type": "Gymnasium/fitness Center", "lighting_secondary_space_type": "Gymnasium Audience Seating", "lighting_power_density": 0.43, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1306,7 +1306,7 @@ "lighting_primary_space_type": "Manufacturing", "lighting_secondary_space_type": "High Bay (25-50 ft Floor to Ceiling Height)", "lighting_power_density": 1.23, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1320,7 +1320,7 @@ "lighting_primary_space_type": "Hotel/Highway Lodging", "lighting_secondary_space_type": "Highway Lodging Dining", "lighting_power_density": 0.88, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1334,7 +1334,7 @@ "lighting_primary_space_type": "Hotel/Highway Lodging", "lighting_secondary_space_type": "Highway Lodging Guest Rooms", "lighting_power_density": 0.75, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1348,7 +1348,7 @@ "lighting_primary_space_type": "Hotel/Highway Lodging", "lighting_secondary_space_type": "Hotel Dining", "lighting_power_density": 0.82, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1362,7 +1362,7 @@ "lighting_primary_space_type": "Hotel/Highway Lodging", "lighting_secondary_space_type": "Hotel Guest Rooms", "lighting_power_density": 1.11, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1376,7 +1376,7 @@ "lighting_primary_space_type": "Hotel/Highway Lodging", "lighting_secondary_space_type": "Hotel Lobby", "lighting_power_density": 1.06, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1390,7 +1390,7 @@ "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", "lighting_secondary_space_type": "Judges' Chambers", "lighting_power_density": 1.17, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1404,7 +1404,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Laundry/Washing", "lighting_power_density": 0.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1418,7 +1418,7 @@ "lighting_primary_space_type": "Dormitory", "lighting_secondary_space_type": "Living Quarters", "lighting_power_density": 0.38, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1432,7 +1432,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Lounge/Recreation", "lighting_power_density": 1.07, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1446,7 +1446,7 @@ "lighting_primary_space_type": "Manufacturing", "lighting_secondary_space_type": "Low Bay (<25 ft Floor to Ceiling Height)", "lighting_power_density": 1.19, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1460,7 +1460,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Mall Concourse", "lighting_power_density": 1.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1474,7 +1474,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Medical Supply", "lighting_power_density": 1.27, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1488,7 +1488,7 @@ "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "Medium/Bulky Material Storage", "lighting_power_density": 0.58, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1502,7 +1502,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Nursery", "lighting_power_density": 0.88, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1516,7 +1516,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Nurses' Station", "lighting_power_density": 0.87, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1530,7 +1530,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Operating Room", "lighting_power_density": 1.89, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1544,7 +1544,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Patient Room", "lighting_power_density": 0.62, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1558,7 +1558,7 @@ "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", "lighting_secondary_space_type": "Penitentiary Audience Seating", "lighting_power_density": 0.43, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1572,7 +1572,7 @@ "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", "lighting_secondary_space_type": "Penitentiary Classroom", "lighting_power_density": 1.34, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1586,7 +1586,7 @@ "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", "lighting_secondary_space_type": "Penitentiary Dining", "lighting_power_density": 1.07, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1600,7 +1600,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Pharmacy", "lighting_power_density": 1.14, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1614,7 +1614,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Physical Therapy", "lighting_power_density": 0.91, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1628,7 +1628,7 @@ "lighting_primary_space_type": "Gymnasium/fitness Center", "lighting_secondary_space_type": "Playing Area", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1642,7 +1642,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Radiology/Imaging", "lighting_power_density": 1.32, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1656,7 +1656,7 @@ "lighting_primary_space_type": "Library", "lighting_secondary_space_type": "Reading Area", "lighting_power_density": 0.93, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1670,7 +1670,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Recovery", "lighting_power_density": 1.15, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1684,7 +1684,7 @@ "lighting_primary_space_type": "Museum", "lighting_secondary_space_type": "Restoration", "lighting_power_density": 1.02, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1698,7 +1698,7 @@ "lighting_primary_space_type": "Sports Arena", "lighting_secondary_space_type": "Ring Sports Area", "lighting_power_density": 2.68, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1712,7 +1712,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Sales Additional (Type 1)", "lighting_power_density": 0.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1726,7 +1726,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Sales Additional (Type 2)", "lighting_power_density": 0.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1740,7 +1740,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Sales Additional (Type 3)", "lighting_power_density": 1.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1754,7 +1754,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Sales Additional (Type 4)", "lighting_power_density": 2.5, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1768,7 +1768,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Sales Area", "lighting_power_density": 1.68, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1782,7 +1782,7 @@ "lighting_primary_space_type": "Automotive", "lighting_secondary_space_type": "Service/Repair", "lighting_power_density": 0.67, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1796,7 +1796,7 @@ "lighting_primary_space_type": "Fire Stations", "lighting_secondary_space_type": "Sleeping Quarters", "lighting_power_density": 0.25, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1810,7 +1810,7 @@ "lighting_primary_space_type": "Library", "lighting_secondary_space_type": "Stacks", "lighting_power_density": 1.71, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1824,7 +1824,7 @@ "lighting_primary_space_type": "Transportation", "lighting_secondary_space_type": "Terminal Ticket Counter", "lighting_power_density": 1.08, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1838,7 +1838,7 @@ "lighting_primary_space_type": "Religious Buildings", "lighting_secondary_space_type": "Worship Pulpit, Choir", "lighting_power_density": 1.53, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1852,7 +1852,7 @@ "lighting_primary_space_type": "None", "lighting_secondary_space_type": "None", "lighting_power_density": 0, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2013.json b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2013.json index 90fc41798d..0e69db14b9 100644 --- a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2013.json +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2013.json @@ -4,7 +4,7 @@ "lighting_primary_space_type": "Automotive Facility", "lighting_secondary_space_type": "General", "lighting_power_density": 0.8, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -18,7 +18,7 @@ "lighting_primary_space_type": "Convention Center", "lighting_secondary_space_type": "General", "lighting_power_density": 1.01, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -32,7 +32,7 @@ "lighting_primary_space_type": "Courthouse", "lighting_secondary_space_type": "General", "lighting_power_density": 1.01, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -46,7 +46,7 @@ "lighting_primary_space_type": "Dining: Bar Lounge/leisure", "lighting_secondary_space_type": "General", "lighting_power_density": 1.01, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -60,7 +60,7 @@ "lighting_primary_space_type": "Dining: Cafeteria/fast Food", "lighting_secondary_space_type": "General", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -74,7 +74,7 @@ "lighting_primary_space_type": "Dining: Family", "lighting_secondary_space_type": "General", "lighting_power_density": 0.95, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -88,7 +88,7 @@ "lighting_primary_space_type": "Dormitory", "lighting_secondary_space_type": "General", "lighting_power_density": 0.57, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -102,7 +102,7 @@ "lighting_primary_space_type": "Exercise Center", "lighting_secondary_space_type": "General", "lighting_power_density": 0.84, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -116,7 +116,7 @@ "lighting_primary_space_type": "Fire Station", "lighting_secondary_space_type": "General", "lighting_power_density": 0.671, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -130,7 +130,7 @@ "lighting_primary_space_type": "Gymnasium", "lighting_secondary_space_type": "General", "lighting_power_density": 0.94, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -144,7 +144,7 @@ "lighting_primary_space_type": "Health-care Clinic", "lighting_secondary_space_type": "General", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -158,7 +158,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "General", "lighting_power_density": 1.05, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -172,7 +172,7 @@ "lighting_primary_space_type": "Hotel/motel", "lighting_secondary_space_type": "General", "lighting_power_density": 0.87, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -186,7 +186,7 @@ "lighting_primary_space_type": "Library", "lighting_secondary_space_type": "General", "lighting_power_density": 1.19, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -200,7 +200,7 @@ "lighting_primary_space_type": "Manufacturing Facility", "lighting_secondary_space_type": "General", "lighting_power_density": 1.17, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -214,7 +214,7 @@ "lighting_primary_space_type": "Motion Picture Theater", "lighting_secondary_space_type": "General", "lighting_power_density": 0.76, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -228,7 +228,7 @@ "lighting_primary_space_type": "Multifamily", "lighting_secondary_space_type": "General", "lighting_power_density": 0.51, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -242,7 +242,7 @@ "lighting_primary_space_type": "Museum", "lighting_secondary_space_type": "General", "lighting_power_density": 1.02, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -256,7 +256,7 @@ "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "General", "lighting_power_density": 0.82, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -270,7 +270,7 @@ "lighting_primary_space_type": "Parking Garage", "lighting_secondary_space_type": "General", "lighting_power_density": 0.21, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -284,7 +284,7 @@ "lighting_primary_space_type": "Penitentiary", "lighting_secondary_space_type": "General", "lighting_power_density": 0.81, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -298,7 +298,7 @@ "lighting_primary_space_type": "Performing Arts Theater", "lighting_secondary_space_type": "General", "lighting_power_density": 1.39, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -312,7 +312,7 @@ "lighting_primary_space_type": "Police Station", "lighting_secondary_space_type": "General", "lighting_power_density": 0.87, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -326,7 +326,7 @@ "lighting_primary_space_type": "Post Office", "lighting_secondary_space_type": "General", "lighting_power_density": 0.87, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -340,7 +340,7 @@ "lighting_primary_space_type": "Religious Building", "lighting_secondary_space_type": "General", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -354,7 +354,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "General", "lighting_power_density": 1.26, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -368,7 +368,7 @@ "lighting_primary_space_type": "School/University", "lighting_secondary_space_type": "General", "lighting_power_density": 0.87, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -382,7 +382,7 @@ "lighting_primary_space_type": "Sports Arena", "lighting_secondary_space_type": "General", "lighting_power_density": 0.91, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -396,7 +396,7 @@ "lighting_primary_space_type": "Town Hall", "lighting_secondary_space_type": "General", "lighting_power_density": 0.89, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -410,7 +410,7 @@ "lighting_primary_space_type": "Transportation", "lighting_secondary_space_type": "General", "lighting_power_density": 0.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -424,7 +424,7 @@ "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "General", "lighting_power_density": 0.66, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -438,7 +438,7 @@ "lighting_primary_space_type": "Workshop", "lighting_secondary_space_type": "General", "lighting_power_density": 1.19, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -452,7 +452,7 @@ "lighting_primary_space_type": "Atrium", "lighting_secondary_space_type": "<20 ft in height", "lighting_power_density": 0.03, - "unit": "W/ft", + "lighting_power_density_unit": "W/ft", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -466,7 +466,7 @@ "lighting_primary_space_type": "Storage Room", "lighting_secondary_space_type": "<50 ft2", "lighting_power_density": 1.24, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -480,7 +480,7 @@ "lighting_primary_space_type": "Atrium", "lighting_secondary_space_type": ">40 ft in height", "lighting_power_density": 0.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -494,7 +494,7 @@ "lighting_primary_space_type": "Atrium", "lighting_secondary_space_type": "gt 20 ft and lt40 ft in height", "lighting_power_density": 0.03, - "unit": "W/ft", + "lighting_power_density_unit": "W/ft", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -508,7 +508,7 @@ "lighting_primary_space_type": "Storage Room", "lighting_secondary_space_type": "gt 50 ft2 and lt 1000 ft2", "lighting_power_density": 0.63, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -522,7 +522,7 @@ "lighting_primary_space_type": "Audience/seating Area", "lighting_secondary_space_type": "all other audience seating areas", "lighting_power_density": 0.43, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -536,7 +536,7 @@ "lighting_primary_space_type": "Classroom/Lecture Hall/Training Room", "lighting_secondary_space_type": "all other classrooms/lecture halls/training rooms", "lighting_power_density": 1.24, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -550,7 +550,7 @@ "lighting_primary_space_type": "Corridor", "lighting_secondary_space_type": "all other corridors", "lighting_power_density": 0.66, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -564,7 +564,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "all other dining areas", "lighting_power_density": 0.65, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -578,7 +578,7 @@ "lighting_primary_space_type": "Laboratory", "lighting_secondary_space_type": "all other laboratories", "lighting_power_density": 1.81, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -592,7 +592,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "all other lobbies", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -606,7 +606,7 @@ "lighting_primary_space_type": "Lounge/Breakroom", "lighting_secondary_space_type": "all other lounges/breakrooms", "lighting_power_density": 0.73, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -620,7 +620,7 @@ "lighting_primary_space_type": "Restroom", "lighting_secondary_space_type": "all other restrooms", "lighting_power_density": 0.98, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -634,7 +634,7 @@ "lighting_primary_space_type": "Storage Room", "lighting_secondary_space_type": "all other storage rooms", "lighting_power_density": 0.63, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -648,7 +648,7 @@ "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "enclosed and >250 ft2", "lighting_power_density": 1.11, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -662,7 +662,7 @@ "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "enclosed and lt 250 ft2", "lighting_power_density": 1.11, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -676,7 +676,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "for an elevator", "lighting_power_density": 0.64, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -690,7 +690,7 @@ "lighting_primary_space_type": "Audience/seating Area", "lighting_secondary_space_type": "in an auditorium", "lighting_power_density": 0.63, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -704,7 +704,7 @@ "lighting_primary_space_type": "Audience/seating Area", "lighting_secondary_space_type": "in a convention center", "lighting_power_density": 0.82, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -718,7 +718,7 @@ "lighting_primary_space_type": "Seating Area, General", "lighting_secondary_space_type": "General", "lighting_power_density": 0.54, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -732,7 +732,7 @@ "lighting_primary_space_type": "Audience/seating Area", "lighting_secondary_space_type": "in a gymnasium", "lighting_power_density": 0.65, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -746,7 +746,7 @@ "lighting_primary_space_type": "Audience/seating Area", "lighting_secondary_space_type": "in a motion picture theater", "lighting_power_density": 1.14, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -760,7 +760,7 @@ "lighting_primary_space_type": "Banking Activity Area", "lighting_secondary_space_type": "General", "lighting_power_density": 1.01, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -774,7 +774,7 @@ "lighting_primary_space_type": "Breakroom", "lighting_secondary_space_type": "General", "lighting_power_density": 0.73, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -788,7 +788,7 @@ "lighting_primary_space_type": "Computer Room", "lighting_secondary_space_type": "General", "lighting_power_density": 1.71, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -802,7 +802,7 @@ "lighting_primary_space_type": "Conference/meeting/multipurpose Room", "lighting_secondary_space_type": "General", "lighting_power_density": 1.23, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -816,7 +816,7 @@ "lighting_primary_space_type": "Confinement Cells", "lighting_secondary_space_type": "General", "lighting_power_density": 0.81, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -830,7 +830,7 @@ "lighting_primary_space_type": "Copy/Print Room", "lighting_secondary_space_type": "General", "lighting_power_density": 0.72, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -844,7 +844,7 @@ "lighting_primary_space_type": "Courtroom", "lighting_secondary_space_type": "General", "lighting_power_density": 1.72, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -858,7 +858,7 @@ "lighting_primary_space_type": "Electrical/Mechanical Room", "lighting_secondary_space_type": "General", "lighting_power_density": 0.42, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -872,7 +872,7 @@ "lighting_primary_space_type": "Emergency Vehicle Garage", "lighting_secondary_space_type": "General", "lighting_power_density": 0.56, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -886,7 +886,7 @@ "lighting_primary_space_type": "Food Preparation Area", "lighting_secondary_space_type": "General", "lighting_power_density": 1.21, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -900,7 +900,7 @@ "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "General", "lighting_power_density": 0.91, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -914,7 +914,7 @@ "lighting_primary_space_type": "Laundry/Washing Area", "lighting_secondary_space_type": "General", "lighting_power_density": 0.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -928,7 +928,7 @@ "lighting_primary_space_type": "Loading Dock, Interior", "lighting_secondary_space_type": "General", "lighting_power_density": 0.47, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -942,7 +942,7 @@ "lighting_primary_space_type": "Locker Room", "lighting_secondary_space_type": "General", "lighting_power_density": 0.75, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -956,7 +956,7 @@ "lighting_primary_space_type": "Parking Area, Interior", "lighting_secondary_space_type": "General", "lighting_power_density": 0.19, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -970,7 +970,7 @@ "lighting_primary_space_type": "Pharmacy Area", "lighting_secondary_space_type": "General", "lighting_power_density": 1.68, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -984,7 +984,7 @@ "lighting_primary_space_type": "Sales Area", "lighting_secondary_space_type": "General", "lighting_power_density": 1.44, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -998,7 +998,7 @@ "lighting_primary_space_type": "Audience/seating Area", "lighting_secondary_space_type": "in a penitentiary", "lighting_power_density": 0.28, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1012,7 +1012,7 @@ "lighting_primary_space_type": "Stairway", "lighting_secondary_space_type": "General", "lighting_power_density": 0.69, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 10, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1026,7 +1026,7 @@ "lighting_primary_space_type": "Stairwell", "lighting_secondary_space_type": "General", "lighting_power_density": 0.69, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 10, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1040,7 +1040,7 @@ "lighting_primary_space_type": "Vehicular Maintenance Area", "lighting_secondary_space_type": "General", "lighting_power_density": 0.67, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1054,7 +1054,7 @@ "lighting_primary_space_type": "Workshop", "lighting_secondary_space_type": "General", "lighting_power_density": 1.59, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1068,7 +1068,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "in a facility for the visually impaired (and not used primarily by staff)", "lighting_power_density": 2.65, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1082,7 +1082,7 @@ "lighting_primary_space_type": "Corridor", "lighting_secondary_space_type": "in a facility for the visually impaired (and not used primarily by the staff)", "lighting_power_density": 0.92, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1096,7 +1096,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "in a facility for the visually impaired (and not used primarily by the staff)", "lighting_power_density": 1.8, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1110,7 +1110,7 @@ "lighting_primary_space_type": "Restroom", "lighting_secondary_space_type": "in a facility for the visually impaired (and not used primarily by the staff)", "lighting_power_density": 1.21, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1124,7 +1124,7 @@ "lighting_primary_space_type": "Lounge/Breakroom", "lighting_secondary_space_type": "in a healthcare facility", "lighting_power_density": 0.92, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1138,7 +1138,7 @@ "lighting_primary_space_type": "Corridor", "lighting_secondary_space_type": "in a hospital", "lighting_power_density": 0.99, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1152,7 +1152,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "in a hotel", "lighting_power_density": 1.06, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1166,7 +1166,7 @@ "lighting_primary_space_type": "Corridor", "lighting_secondary_space_type": "in a manufacturing facility", "lighting_power_density": 0.41, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1180,7 +1180,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "in a motion picture theater", "lighting_power_density": 0.59, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1194,7 +1194,7 @@ "lighting_primary_space_type": "Audience/seating Area", "lighting_secondary_space_type": "in a performing arts theater", "lighting_power_density": 2.43, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1208,7 +1208,7 @@ "lighting_primary_space_type": "Classroom/Lecture Hall/Training Room", "lighting_secondary_space_type": "in a penitentiary", "lighting_power_density": 1.34, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1222,7 +1222,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "in a penitentiary", "lighting_power_density": 0.96, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1236,7 +1236,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "in a performing arts theater", "lighting_power_density": 2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1250,7 +1250,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "in bar/lounge or leisure dining", "lighting_power_density": 1.07, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1264,7 +1264,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "in cafeteria or fast food dining", "lighting_power_density": 0.65, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1278,7 +1278,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "in family dining", "lighting_power_density": 0.89, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1292,7 +1292,7 @@ "lighting_primary_space_type": "Laboratory", "lighting_secondary_space_type": "in or as a classroom", "lighting_power_density": 1.43, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1306,7 +1306,7 @@ "lighting_primary_space_type": "Audience/seating Area", "lighting_secondary_space_type": "in a religious building", "lighting_power_density": 1.53, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1320,7 +1320,7 @@ "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "open plan", "lighting_power_density": 0.98, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1334,7 +1334,7 @@ "lighting_primary_space_type": "Audience/seating Area", "lighting_secondary_space_type": "in a sports arena", "lighting_power_density": 0.43, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1348,7 +1348,7 @@ "lighting_primary_space_type": "Religious Buildings", "lighting_secondary_space_type": "a worship/pulpit/choir area", "lighting_power_density": 1.53, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1362,7 +1362,7 @@ "lighting_primary_space_type": "Transportation Facility", "lighting_secondary_space_type": "at a terminal ticket counter", "lighting_power_density": 0.8, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1376,7 +1376,7 @@ "lighting_primary_space_type": "Sports Arena Playing Area", "lighting_secondary_space_type": "for a Class I facility", "lighting_power_density": 3.68, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1390,7 +1390,7 @@ "lighting_primary_space_type": "Sports Arena Playing Area", "lighting_secondary_space_type": "for a Class II facility", "lighting_power_density": 2.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1404,7 +1404,7 @@ "lighting_primary_space_type": "Sports Arena Playing Area", "lighting_secondary_space_type": "for a Class III facility", "lighting_power_density": 1.8, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1418,7 +1418,7 @@ "lighting_primary_space_type": "Sports Arena Playing Area", "lighting_secondary_space_type": "for a Class IV facility", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1432,7 +1432,7 @@ "lighting_primary_space_type": "Warehouse storage Area", "lighting_secondary_space_type": "for medium to bulky, palletized items", "lighting_power_density": 0.58, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1446,7 +1446,7 @@ "lighting_primary_space_type": "Warehouse storage Area", "lighting_secondary_space_type": "for smaller, hand-carried items", "lighting_power_density": 0.95, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1460,7 +1460,7 @@ "lighting_primary_space_type": "Automotive", "lighting_secondary_space_type": "General", "lighting_power_density": 0.67, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1474,7 +1474,7 @@ "lighting_primary_space_type": "Convention Center Exhibit Space", "lighting_secondary_space_type": "General", "lighting_power_density": 1.45, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1488,7 +1488,7 @@ "lighting_primary_space_type": "Dormitory Living Quarters", "lighting_secondary_space_type": "General", "lighting_power_density": 0.38, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1502,7 +1502,7 @@ "lighting_primary_space_type": "Fire Station Sleeping Quarters", "lighting_secondary_space_type": "General", "lighting_power_density": 0.22, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1516,7 +1516,7 @@ "lighting_primary_space_type": "Performing Arts Theater Dressing Room", "lighting_secondary_space_type": "General", "lighting_power_density": 0.61, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1530,7 +1530,7 @@ "lighting_primary_space_type": "Post Office Sorting Area", "lighting_secondary_space_type": "General", "lighting_power_density": 0.94, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1544,7 +1544,7 @@ "lighting_primary_space_type": "Transportation Facility", "lighting_secondary_space_type": "in a baggage/carousel area", "lighting_power_density": 0.53, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1558,7 +1558,7 @@ "lighting_primary_space_type": "Facility For The Visually Impaired", "lighting_secondary_space_type": "in a chapel (used primarily by residents)", "lighting_power_density": 2.21, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1572,7 +1572,7 @@ "lighting_primary_space_type": "Manufacturing Facility", "lighting_secondary_space_type": "in a detailed manufacturing area", "lighting_power_density": 1.29, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1586,7 +1586,7 @@ "lighting_primary_space_type": "Retail Facilities", "lighting_secondary_space_type": "in a dressing/fitting room", "lighting_power_density": 0.71, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1600,7 +1600,7 @@ "lighting_primary_space_type": "Religious Buildings", "lighting_secondary_space_type": "in a fellowship hall", "lighting_power_density": 0.64, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1614,7 +1614,7 @@ "lighting_primary_space_type": "Museum", "lighting_secondary_space_type": "in a general exhibition area", "lighting_power_density": 1.05, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1628,7 +1628,7 @@ "lighting_primary_space_type": "Manufacturing Facility", "lighting_secondary_space_type": "in a high bay area (25 50 ft floor-to-ceiling height)", "lighting_power_density": 1.23, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1642,7 +1642,7 @@ "lighting_primary_space_type": "Manufacturing Facility", "lighting_secondary_space_type": "in a low bay area (<25 ft floor-to-ceiling height)", "lighting_power_density": 1.19, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1656,7 +1656,7 @@ "lighting_primary_space_type": "Retail Facilities", "lighting_secondary_space_type": "in a mall concourse", "lighting_power_density": 1.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1670,7 +1670,7 @@ "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "in a medical supply room", "lighting_power_density": 0.74, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1684,7 +1684,7 @@ "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "in a nurse s station", "lighting_power_density": 0.71, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1698,7 +1698,7 @@ "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "in a nursery", "lighting_power_density": 0.88, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1712,7 +1712,7 @@ "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "in a patient room", "lighting_power_density": 0.62, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1726,7 +1726,7 @@ "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "in a physical therapy room", "lighting_power_density": 0.91, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1740,7 +1740,7 @@ "lighting_primary_space_type": "Gymnasium/fitness Center", "lighting_secondary_space_type": "in a playing area", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1754,7 +1754,7 @@ "lighting_primary_space_type": "Library", "lighting_secondary_space_type": "in a reading area", "lighting_power_density": 1.06, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1768,7 +1768,7 @@ "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "in a recovery room", "lighting_power_density": 1.15, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1782,7 +1782,7 @@ "lighting_primary_space_type": "Facility For The Visually Impaired", "lighting_secondary_space_type": "in a recreation room/common living room (and not used primarily by staff)", "lighting_power_density": 2.41, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1796,7 +1796,7 @@ "lighting_primary_space_type": "Facility For The Visually Impaired", "lighting_secondary_space_type": "in a recreation room/common living room (and not used primarily by staff)", "lighting_power_density": 2.41, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1810,7 +1810,7 @@ "lighting_primary_space_type": "Museum", "lighting_secondary_space_type": "in a restoration room", "lighting_power_density": 1.02, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1824,7 +1824,7 @@ "lighting_primary_space_type": "Transportation Facility", "lighting_secondary_space_type": "in an airport concourse", "lighting_power_density": 0.36, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1838,7 +1838,7 @@ "lighting_primary_space_type": "Manufacturing Facility", "lighting_secondary_space_type": "in an equipment room", "lighting_power_density": 0.74, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1852,7 +1852,7 @@ "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "in an exam/treatment room", "lighting_power_density": 1.66, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1866,7 +1866,7 @@ "lighting_primary_space_type": "Gymnasium/fitness Center", "lighting_secondary_space_type": "in an exercise area", "lighting_power_density": 0.72, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1880,7 +1880,7 @@ "lighting_primary_space_type": "Manufacturing Facility", "lighting_secondary_space_type": "in an extra high bay area (>50 ft floor-to-ceiling height)", "lighting_power_density": 1.05, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1894,7 +1894,7 @@ "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "in an imaging room", "lighting_power_density": 1.51, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1908,7 +1908,7 @@ "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "in an operating room", "lighting_power_density": 2.48, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1922,7 +1922,7 @@ "lighting_primary_space_type": "Library", "lighting_secondary_space_type": "in the stacks", "lighting_power_density": 1.71, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1936,7 +1936,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Sales Additional (Type 1)", "lighting_power_density": 0.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1950,7 +1950,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Sales Additional (Type 2)", "lighting_power_density": 0.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1964,7 +1964,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Sales Additional (Type 3)", "lighting_power_density": 1.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1978,7 +1978,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Sales Additional (Type 4)", "lighting_power_density": 2.5, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1992,7 +1992,7 @@ "lighting_primary_space_type": "None", "lighting_secondary_space_type": "None", "lighting_power_density": 0, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.json b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.json index ae014f65c9..426756789d 100644 --- a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.json +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.json @@ -4,7 +4,7 @@ "lighting_primary_space_type": "Automotive Facility", "lighting_secondary_space_type": "General", "lighting_power_density": 0.71, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -18,7 +18,7 @@ "lighting_primary_space_type": "Convention Center", "lighting_secondary_space_type": "General", "lighting_power_density": 0.76, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -32,7 +32,7 @@ "lighting_primary_space_type": "Courthouse", "lighting_secondary_space_type": "General", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -46,7 +46,7 @@ "lighting_primary_space_type": "Dining: Bar Lounge/leisure", "lighting_secondary_space_type": "General", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -60,7 +60,7 @@ "lighting_primary_space_type": "Dining: Cafeteria/Fast Food", "lighting_secondary_space_type": "General", "lighting_power_density": 0.79, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -74,7 +74,7 @@ "lighting_primary_space_type": "Dining: Family", "lighting_secondary_space_type": "General", "lighting_power_density": 0.78, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -88,7 +88,7 @@ "lighting_primary_space_type": "Dormitory", "lighting_secondary_space_type": "General", "lighting_power_density": 0.61, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -102,7 +102,7 @@ "lighting_primary_space_type": "Exercise Center", "lighting_secondary_space_type": "General", "lighting_power_density": 0.65, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -116,7 +116,7 @@ "lighting_primary_space_type": "Fire Station", "lighting_secondary_space_type": "General", "lighting_power_density": 0.53, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -130,7 +130,7 @@ "lighting_primary_space_type": "Gymnasium", "lighting_secondary_space_type": "General", "lighting_power_density": 0.68, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -144,7 +144,7 @@ "lighting_primary_space_type": "Health-care Clinic", "lighting_secondary_space_type": "General", "lighting_power_density": 0.82, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -158,7 +158,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "General", "lighting_power_density": 1.05, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -172,7 +172,7 @@ "lighting_primary_space_type": "Hotel/motel", "lighting_secondary_space_type": "General", "lighting_power_density": 0.75, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -186,7 +186,7 @@ "lighting_primary_space_type": "Library", "lighting_secondary_space_type": "General", "lighting_power_density": 0.78, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -200,7 +200,7 @@ "lighting_primary_space_type": "Manufacturing Facility", "lighting_secondary_space_type": "General", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -214,7 +214,7 @@ "lighting_primary_space_type": "Motion Picture Theater", "lighting_secondary_space_type": "General", "lighting_power_density": 0.83, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -228,7 +228,7 @@ "lighting_primary_space_type": "Multifamily", "lighting_secondary_space_type": "General", "lighting_power_density": 0.68, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -242,7 +242,7 @@ "lighting_primary_space_type": "Museum", "lighting_secondary_space_type": "General", "lighting_power_density": 1.06, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -256,7 +256,7 @@ "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "General", "lighting_power_density": 0.79, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -270,7 +270,7 @@ "lighting_primary_space_type": "Parking Garage", "lighting_secondary_space_type": "General", "lighting_power_density": 0.15, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -284,7 +284,7 @@ "lighting_primary_space_type": "Penitentiary", "lighting_secondary_space_type": "General", "lighting_power_density": 0.75, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -298,7 +298,7 @@ "lighting_primary_space_type": "Performing Arts Theater", "lighting_secondary_space_type": "General", "lighting_power_density": 1.18, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -312,7 +312,7 @@ "lighting_primary_space_type": "Police Station", "lighting_secondary_space_type": "General", "lighting_power_density": 0.8, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -326,7 +326,7 @@ "lighting_primary_space_type": "Post Office", "lighting_secondary_space_type": "General", "lighting_power_density": 0.67, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -340,7 +340,7 @@ "lighting_primary_space_type": "Religious Facility", "lighting_secondary_space_type": "General", "lighting_power_density": 0.94, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -354,7 +354,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "General", "lighting_power_density": 1.06, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -368,7 +368,7 @@ "lighting_primary_space_type": "School/University", "lighting_secondary_space_type": "General", "lighting_power_density": 0.81, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -382,7 +382,7 @@ "lighting_primary_space_type": "Sports Arena", "lighting_secondary_space_type": "General", "lighting_power_density": 0.87, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -396,7 +396,7 @@ "lighting_primary_space_type": "Town Hall", "lighting_secondary_space_type": "General", "lighting_power_density": 0.8, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -410,7 +410,7 @@ "lighting_primary_space_type": "Transportation", "lighting_secondary_space_type": "General", "lighting_power_density": 0.61, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -424,7 +424,7 @@ "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "General", "lighting_power_density": 0.48, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -438,7 +438,7 @@ "lighting_primary_space_type": "Workshop", "lighting_secondary_space_type": "General", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -452,7 +452,7 @@ "lighting_primary_space_type": "Atrium", "lighting_secondary_space_type": "<20 ft in height", "lighting_power_density": 0.03, - "unit": "W/ft", + "lighting_power_density_unit": "W/ft", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -466,7 +466,7 @@ "lighting_primary_space_type": "Storage Room", "lighting_secondary_space_type": "<50 Ft2", "lighting_power_density": 0.97, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -480,7 +480,7 @@ "lighting_primary_space_type": "Atrium", "lighting_secondary_space_type": ">40 ft in height", "lighting_power_density": 0.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -494,7 +494,7 @@ "lighting_primary_space_type": "Atrium", "lighting_secondary_space_type": "gt 20 ft and lt 40 ft in height", "lighting_power_density": 0.03, - "unit": "W/ft", + "lighting_power_density_unit": "W/ft", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -508,7 +508,7 @@ "lighting_primary_space_type": "Storage Room", "lighting_secondary_space_type": "gt 50 Ft2 And lt 1000 Ft2", "lighting_power_density": 0.46, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -522,7 +522,7 @@ "lighting_primary_space_type": "Audience Seating Area", "lighting_secondary_space_type": "All Other Audience Seating Areas", "lighting_power_density": 0.43, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -536,7 +536,7 @@ "lighting_primary_space_type": "Classroom/lecture Hall/training Room", "lighting_secondary_space_type": "All Other Classrooms/lecture Halls/training Rooms", "lighting_power_density": 0.92, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -550,7 +550,7 @@ "lighting_primary_space_type": "Corridor", "lighting_secondary_space_type": "All Other Corridors", "lighting_power_density": 0.66, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -564,7 +564,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "All Other Dining Areas", "lighting_power_density": 0.63, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -578,7 +578,7 @@ "lighting_primary_space_type": "Laboratory", "lighting_secondary_space_type": "All Other Laboratories", "lighting_power_density": 1.45, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -592,7 +592,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "All Other Lobbies", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -606,7 +606,7 @@ "lighting_primary_space_type": "Lounge/Breakroom", "lighting_secondary_space_type": "All Other Lounges/breakrooms", "lighting_power_density": 0.62, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -620,7 +620,7 @@ "lighting_primary_space_type": "Restroom", "lighting_secondary_space_type": "All Other Restrooms", "lighting_power_density": 0.85, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -634,7 +634,7 @@ "lighting_primary_space_type": "Storage Room", "lighting_secondary_space_type": "All Other Storage Rooms", "lighting_power_density": 0.46, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -648,7 +648,7 @@ "lighting_primary_space_type": "Audience Seating Area", "lighting_secondary_space_type": "Auditorium", "lighting_power_density": 0.63, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -662,7 +662,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "Bar/lounge Or Leisure Dining", "lighting_power_density": 0.93, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -676,7 +676,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "Cafeteria Or Fast Food Dining", "lighting_power_density": 0.63, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -690,7 +690,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "Elevator", "lighting_power_density": 0.69, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -704,7 +704,7 @@ "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "Enclosed And >250 Ft2", "lighting_power_density": 0.93, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -718,7 +718,7 @@ "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "Enclosed And gt 250 Ft2", "lighting_power_density": 0.93, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -732,7 +732,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "Facility For The Visually Impaired (and Not Used Primarily By Staff)", "lighting_power_density": 2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -746,7 +746,7 @@ "lighting_primary_space_type": "Corridor", "lighting_secondary_space_type": "Facility For The Visually Impaired (and Not Used Primarily By The Staff)", "lighting_power_density": 0.92, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -760,7 +760,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "Facility For The Visually Impaired (and Not Used Primarily By The Staff)", "lighting_power_density": 2.03, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -774,7 +774,7 @@ "lighting_primary_space_type": "Restroom", "lighting_secondary_space_type": "Facility For The Visually Impaired (and Not Used Primarily By The Staff)", "lighting_power_density": 0.96, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -788,7 +788,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "Family Dining", "lighting_power_density": 0.71, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -802,7 +802,7 @@ "lighting_primary_space_type": "Audience Seating Area", "lighting_secondary_space_type": "Convention Center", "lighting_power_density": 0.82, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -816,7 +816,7 @@ "lighting_primary_space_type": "Seating Area, General", "lighting_secondary_space_type": "General", "lighting_power_density": 0.42, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -830,7 +830,7 @@ "lighting_primary_space_type": "Audience Seating Area", "lighting_secondary_space_type": "Gymnasium", "lighting_power_density": 0.65, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -844,7 +844,7 @@ "lighting_primary_space_type": "Audience Seating Area", "lighting_secondary_space_type": "Motion Picture Theater", "lighting_power_density": 1.14, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -858,7 +858,7 @@ "lighting_primary_space_type": "Banking Activity Area", "lighting_secondary_space_type": "General", "lighting_power_density": 0.86, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -872,7 +872,7 @@ "lighting_primary_space_type": "Breakroom", "lighting_secondary_space_type": "General", "lighting_power_density": 0.62, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -886,7 +886,7 @@ "lighting_primary_space_type": "Computer Room", "lighting_secondary_space_type": "General", "lighting_power_density": 1.33, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -900,7 +900,7 @@ "lighting_primary_space_type": "Conference/meeting/multipurpose Room", "lighting_secondary_space_type": "General", "lighting_power_density": 1.07, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -914,7 +914,7 @@ "lighting_primary_space_type": "Confinement Cells", "lighting_secondary_space_type": "General", "lighting_power_density": 0.81, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -928,7 +928,7 @@ "lighting_primary_space_type": "Copy/Print Room", "lighting_secondary_space_type": "General", "lighting_power_density": 0.56, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -942,7 +942,7 @@ "lighting_primary_space_type": "Courtroom", "lighting_secondary_space_type": "General", "lighting_power_density": 1.39, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -956,7 +956,7 @@ "lighting_primary_space_type": "Electrical/mechanical Room", "lighting_secondary_space_type": "General", "lighting_power_density": 0.43, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -970,7 +970,7 @@ "lighting_primary_space_type": "Emergency Vehicle Garage", "lighting_secondary_space_type": "General", "lighting_power_density": 0.41, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -984,7 +984,7 @@ "lighting_primary_space_type": "Food Preparation Area", "lighting_secondary_space_type": "General", "lighting_power_density": 1.06, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -998,7 +998,7 @@ "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "General", "lighting_power_density": 0.77, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1012,7 +1012,7 @@ "lighting_primary_space_type": "Laundry/washing Area", "lighting_secondary_space_type": "General", "lighting_power_density": 0.43, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1026,7 +1026,7 @@ "lighting_primary_space_type": "Loading Dock, Interior", "lighting_secondary_space_type": "General", "lighting_power_density": 0.58, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1040,7 +1040,7 @@ "lighting_primary_space_type": "Locker Room", "lighting_secondary_space_type": "General", "lighting_power_density": 0.48, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1054,7 +1054,7 @@ "lighting_primary_space_type": "Parking Area, Interior", "lighting_secondary_space_type": "General", "lighting_power_density": 0.14, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1068,7 +1068,7 @@ "lighting_primary_space_type": "Pharmacy Area", "lighting_secondary_space_type": "General", "lighting_power_density": 1.34, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1082,7 +1082,7 @@ "lighting_primary_space_type": "Sales Area", "lighting_secondary_space_type": "General", "lighting_power_density": 1.22, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 3, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1096,7 +1096,7 @@ "lighting_primary_space_type": "Stairway", "lighting_secondary_space_type": "General", "lighting_power_density": 0.58, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 10, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1110,7 +1110,7 @@ "lighting_primary_space_type": "Stairwell", "lighting_secondary_space_type": "General", "lighting_power_density": 0.58, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 10, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1124,7 +1124,7 @@ "lighting_primary_space_type": "Vehicular Maintenance Area", "lighting_secondary_space_type": "General", "lighting_power_density": 0.56, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1138,7 +1138,7 @@ "lighting_primary_space_type": "Workshop", "lighting_secondary_space_type": "General", "lighting_power_density": 1.14, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1152,7 +1152,7 @@ "lighting_primary_space_type": "Audience Seating Area", "lighting_secondary_space_type": "Penitentiary", "lighting_power_density": 0.28, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1166,7 +1166,7 @@ "lighting_primary_space_type": "Lounge/Breakroom", "lighting_secondary_space_type": "Healthcare Facility", "lighting_power_density": 0.78, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1180,7 +1180,7 @@ "lighting_primary_space_type": "Corridor", "lighting_secondary_space_type": "Hospital", "lighting_power_density": 0.92, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1194,7 +1194,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "Hotel", "lighting_power_density": 1.06, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1208,7 +1208,7 @@ "lighting_primary_space_type": "Audience Seating Area", "lighting_secondary_space_type": "Performing Arts Theater", "lighting_power_density": 2.03, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1222,7 +1222,7 @@ "lighting_primary_space_type": "Laboratory", "lighting_secondary_space_type": "In Or As A Classroom", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1236,7 +1236,7 @@ "lighting_primary_space_type": "Corridor", "lighting_secondary_space_type": "Manufacturing Facility", "lighting_power_density": 0.29, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1250,7 +1250,7 @@ "lighting_primary_space_type": "Audience Seating Area", "lighting_secondary_space_type": "Religious Facility", "lighting_power_density": 1.53, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1264,7 +1264,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "Motion Picture Theater", "lighting_power_density": 0.45, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1278,7 +1278,7 @@ "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "Open Plan", "lighting_power_density": 0.81, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1292,7 +1292,7 @@ "lighting_primary_space_type": "Classroom/lecture Hall/training Room", "lighting_secondary_space_type": "Penitentiary", "lighting_power_density": 1.34, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1306,7 +1306,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "Penitentiary", "lighting_power_density": 0.96, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1320,7 +1320,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "Performing Arts Theater", "lighting_power_density": 1.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1334,7 +1334,7 @@ "lighting_primary_space_type": "Audience Seating Area", "lighting_secondary_space_type": "Sports Arena", "lighting_power_density": 0.43, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1348,7 +1348,7 @@ "lighting_primary_space_type": "Transportation Facility", "lighting_secondary_space_type": "Airport Concourse", "lighting_power_density": 0.31, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1362,7 +1362,7 @@ "lighting_primary_space_type": "Transportation Facility", "lighting_secondary_space_type": "Baggage/carousel Area", "lighting_power_density": 0.46, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1376,7 +1376,7 @@ "lighting_primary_space_type": "Facility For The Visually Impaired", "lighting_secondary_space_type": "Chapel (used Primarily By Residents)", "lighting_power_density": 1.06, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1390,7 +1390,7 @@ "lighting_primary_space_type": "Sports Arena-playing Area", "lighting_secondary_space_type": "Class I Facility", "lighting_power_density": 2.47, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1404,7 +1404,7 @@ "lighting_primary_space_type": "Sports Arena-playing Area", "lighting_secondary_space_type": "Class II Facility", "lighting_power_density": 1.96, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1418,7 +1418,7 @@ "lighting_primary_space_type": "Sports Arena-playing Area", "lighting_secondary_space_type": "Class Iii Facility", "lighting_power_density": 1.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1432,7 +1432,7 @@ "lighting_primary_space_type": "Sports Arena-playing Area", "lighting_secondary_space_type": "Class Iv Facility", "lighting_power_density": 1.13, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1446,7 +1446,7 @@ "lighting_primary_space_type": "Manufacturing Facility", "lighting_secondary_space_type": "Detailed Manufacturing Area", "lighting_power_density": 0.93, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1460,7 +1460,7 @@ "lighting_primary_space_type": "Retail Facilities", "lighting_secondary_space_type": "Dressing/Fitting Room", "lighting_power_density": 0.5, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1474,7 +1474,7 @@ "lighting_primary_space_type": "Manufacturing Facility", "lighting_secondary_space_type": "Equipment Room", "lighting_power_density": 0.65, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1488,7 +1488,7 @@ "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Exam/treatment Room", "lighting_power_density": 1.68, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1502,7 +1502,7 @@ "lighting_primary_space_type": "Gymnasium/fitness Center", "lighting_secondary_space_type": "Exercise Area", "lighting_power_density": 0.5, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1516,7 +1516,7 @@ "lighting_primary_space_type": "Manufacturing Facility", "lighting_secondary_space_type": "Extra High Bay Area (>50 Ft Floor-to-ceiling Height)", "lighting_power_density": 1.05, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1530,7 +1530,7 @@ "lighting_primary_space_type": "Religious Facility", "lighting_secondary_space_type": "Fellowship Hall", "lighting_power_density": 0.55, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1544,7 +1544,7 @@ "lighting_primary_space_type": "Automotive", "lighting_secondary_space_type": "General", "lighting_power_density": 0.56, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1558,7 +1558,7 @@ "lighting_primary_space_type": "Convention Center-exhibit Space", "lighting_secondary_space_type": "General", "lighting_power_density": 0.88, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1572,7 +1572,7 @@ "lighting_primary_space_type": "Dormitory-living Quarters", "lighting_secondary_space_type": "General", "lighting_power_density": 0.54, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1586,7 +1586,7 @@ "lighting_primary_space_type": "Fire Station-sleeping Quarters", "lighting_secondary_space_type": "General", "lighting_power_density": 0.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1600,7 +1600,7 @@ "lighting_primary_space_type": "Performing Arts Theater-dressing Room", "lighting_secondary_space_type": "General", "lighting_power_density": 0.36, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1614,7 +1614,7 @@ "lighting_primary_space_type": "Post Office-sorting Area", "lighting_secondary_space_type": "General", "lighting_power_density": 0.68, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1628,7 +1628,7 @@ "lighting_primary_space_type": "Museum", "lighting_secondary_space_type": "General Exhibition Area", "lighting_power_density": 1.05, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1642,7 +1642,7 @@ "lighting_primary_space_type": "Manufacturing Facility", "lighting_secondary_space_type": "High Bay Area (25 To 50 Ft Floor-to-ceiling Height)", "lighting_power_density": 0.75, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1656,7 +1656,7 @@ "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Imaging Room", "lighting_power_density": 1.06, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1670,7 +1670,7 @@ "lighting_primary_space_type": "Manufacturing Facility", "lighting_secondary_space_type": "Low Bay Area (<25 Ft Floor-to-ceiling Height)", "lighting_power_density": 0.96, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1684,7 +1684,7 @@ "lighting_primary_space_type": "Retail Facilities", "lighting_secondary_space_type": "Mall Concourse", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1698,7 +1698,7 @@ "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Medical Supply Room", "lighting_power_density": 0.54, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1712,7 +1712,7 @@ "lighting_primary_space_type": "Warehouse-storage Area", "lighting_secondary_space_type": "Medium To Bulky, Palletized Items", "lighting_power_density": 0.35, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1726,7 +1726,7 @@ "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Nurse\u00c3\u00a2\u00e2\u201a\u00ac\u00e2\u201e\u00a2s Station", "lighting_power_density": 0.81, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1740,7 +1740,7 @@ "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Nursery", "lighting_power_density": 1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1754,7 +1754,7 @@ "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Operating Room", "lighting_power_density": 2.17, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1768,7 +1768,7 @@ "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Patient Room", "lighting_power_density": 0.62, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1782,7 +1782,7 @@ "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Physical Therapy Room", "lighting_power_density": 0.84, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1796,7 +1796,7 @@ "lighting_primary_space_type": "Gymnasium/fitness Center", "lighting_secondary_space_type": "Playing Area", "lighting_power_density": 0.82, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1810,7 +1810,7 @@ "lighting_primary_space_type": "Library", "lighting_secondary_space_type": "Reading Area", "lighting_power_density": 0.82, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1824,7 +1824,7 @@ "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Recovery Room", "lighting_power_density": 1.03, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1838,7 +1838,7 @@ "lighting_primary_space_type": "Facility For The Visually Impaired", "lighting_secondary_space_type": "Recreation Room/common Living Room (and Not Used Primarily By Staff)", "lighting_power_density": 1.8, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1852,7 +1852,7 @@ "lighting_primary_space_type": "Museum", "lighting_secondary_space_type": "Restoration Room", "lighting_power_density": 0.85, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1866,7 +1866,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Sales Additional (type 1)", "lighting_power_density": 0.45, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1880,7 +1880,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Sales Additional (type 2)", "lighting_power_density": 0.45, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1894,7 +1894,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Sales Additional (type 3)", "lighting_power_density": 1.05, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1908,7 +1908,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Sales Additional (type 4)", "lighting_power_density": 1.88, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1922,7 +1922,7 @@ "lighting_primary_space_type": "Warehouse-storage Area", "lighting_secondary_space_type": "Smaller, Hand-carried Items", "lighting_power_density": 0.69, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1936,7 +1936,7 @@ "lighting_primary_space_type": "Library", "lighting_secondary_space_type": "Stacks", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1950,7 +1950,7 @@ "lighting_primary_space_type": "Transportation Facility", "lighting_secondary_space_type": "Terminal Ticket Counter", "lighting_power_density": 0.62, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1964,7 +1964,7 @@ "lighting_primary_space_type": "Religious Facility", "lighting_secondary_space_type": "Worship/Pulpit/Choir Area", "lighting_power_density": 1.53, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1978,7 +1978,7 @@ "lighting_primary_space_type": "None", "lighting_secondary_space_type": "None", "lighting_power_density": 0, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2019.json b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2019.json index 63f5789ebe..76e38875f3 100644 --- a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2019.json +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2019.json @@ -4,7 +4,7 @@ "lighting_primary_space_type": "Automotive facility", "lighting_secondary_space_type": "General", "lighting_power_density": 0.75, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -18,7 +18,7 @@ "lighting_primary_space_type": "Convention center", "lighting_secondary_space_type": "General", "lighting_power_density": 0.64, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -32,7 +32,7 @@ "lighting_primary_space_type": "Courthouse", "lighting_secondary_space_type": "General", "lighting_power_density": 0.79, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -46,7 +46,7 @@ "lighting_primary_space_type": "Dining: Bar lounge/leisure", "lighting_secondary_space_type": "General", "lighting_power_density": 0.8, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -60,7 +60,7 @@ "lighting_primary_space_type": "Dining: Cafeteria/fast food", "lighting_secondary_space_type": "General", "lighting_power_density": 0.76, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -74,7 +74,7 @@ "lighting_primary_space_type": "Dining: Family", "lighting_secondary_space_type": "General", "lighting_power_density": 0.71, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -88,7 +88,7 @@ "lighting_primary_space_type": "Dormitory", "lighting_secondary_space_type": "General", "lighting_power_density": 0.53, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -102,7 +102,7 @@ "lighting_primary_space_type": "Exercise center", "lighting_secondary_space_type": "General", "lighting_power_density": 0.72, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -116,7 +116,7 @@ "lighting_primary_space_type": "Fire station", "lighting_secondary_space_type": "General", "lighting_power_density": 0.56, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -130,7 +130,7 @@ "lighting_primary_space_type": "Gymnasium", "lighting_secondary_space_type": "General", "lighting_power_density": 0.76, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -144,7 +144,7 @@ "lighting_primary_space_type": "Health-care clinic", "lighting_secondary_space_type": "General", "lighting_power_density": 0.81, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -158,7 +158,7 @@ "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "General", "lighting_power_density": 0.96, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -172,7 +172,7 @@ "lighting_primary_space_type": "Hotel/motel", "lighting_secondary_space_type": "General", "lighting_power_density": 0.56, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -186,7 +186,7 @@ "lighting_primary_space_type": "Library", "lighting_secondary_space_type": "General", "lighting_power_density": 0.83, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -200,7 +200,7 @@ "lighting_primary_space_type": "Manufacturing facility", "lighting_secondary_space_type": "General", "lighting_power_density": 0.82, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -214,7 +214,7 @@ "lighting_primary_space_type": "Motion picture theater", "lighting_secondary_space_type": "General", "lighting_power_density": 0.44, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -228,7 +228,7 @@ "lighting_primary_space_type": "Multifamily", "lighting_secondary_space_type": "General", "lighting_power_density": 0.45, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -242,7 +242,7 @@ "lighting_primary_space_type": "Museum", "lighting_secondary_space_type": "General", "lighting_power_density": 0.55, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -256,7 +256,7 @@ "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "General", "lighting_power_density": 0.64, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -270,7 +270,7 @@ "lighting_primary_space_type": "Parking garage", "lighting_secondary_space_type": "General", "lighting_power_density": 0.18, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -284,7 +284,7 @@ "lighting_primary_space_type": "Penitentiary", "lighting_secondary_space_type": "General", "lighting_power_density": 0.69, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -298,7 +298,7 @@ "lighting_primary_space_type": "Performing arts theater", "lighting_secondary_space_type": "General", "lighting_power_density": 0.84, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -312,7 +312,7 @@ "lighting_primary_space_type": "Police station", "lighting_secondary_space_type": "General", "lighting_power_density": 0.66, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -326,7 +326,7 @@ "lighting_primary_space_type": "Post office", "lighting_secondary_space_type": "General", "lighting_power_density": 0.65, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -340,7 +340,7 @@ "lighting_primary_space_type": "Religious facility", "lighting_secondary_space_type": "General", "lighting_power_density": 0.67, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -354,7 +354,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "General", "lighting_power_density": 0.84, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -368,7 +368,7 @@ "lighting_primary_space_type": "School/university", "lighting_secondary_space_type": "General", "lighting_power_density": 0.72, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -382,7 +382,7 @@ "lighting_primary_space_type": "Sports arena", "lighting_secondary_space_type": "General", "lighting_power_density": 0.76, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -396,7 +396,7 @@ "lighting_primary_space_type": "Town hall", "lighting_secondary_space_type": "General", "lighting_power_density": 0.69, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -410,7 +410,7 @@ "lighting_primary_space_type": "Transportation", "lighting_secondary_space_type": "General", "lighting_power_density": 0.5, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -424,7 +424,7 @@ "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "General", "lighting_power_density": 0.45, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -438,7 +438,7 @@ "lighting_primary_space_type": "Workshop", "lighting_secondary_space_type": "General", "lighting_power_density": 0.91, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -452,7 +452,7 @@ "lighting_primary_space_type": "Atrium", "lighting_secondary_space_type": "< 20 ft in height", "lighting_power_density": 0.39, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -466,7 +466,7 @@ "lighting_primary_space_type": "Atrium", "lighting_secondary_space_type": ">= 20 ft and <= 40 ft in height", "lighting_power_density": 0.48, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -480,7 +480,7 @@ "lighting_primary_space_type": "Atrium", "lighting_secondary_space_type": "> 40 ft in height", "lighting_power_density": 0.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 11, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -494,7 +494,7 @@ "lighting_primary_space_type": "Audience Seating Area", "lighting_secondary_space_type": "Auditorium", "lighting_power_density": 0.61, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -508,7 +508,7 @@ "lighting_primary_space_type": "Audience Seating Area", "lighting_secondary_space_type": "Gymnasium", "lighting_power_density": 0.23, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -522,7 +522,7 @@ "lighting_primary_space_type": "Audience Seating Area", "lighting_secondary_space_type": "Motion picture theater", "lighting_power_density": 0.27, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -536,7 +536,7 @@ "lighting_primary_space_type": "Audience Seating Area", "lighting_secondary_space_type": "Penitentiary", "lighting_power_density": 0.67, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -550,7 +550,7 @@ "lighting_primary_space_type": "Audience Seating Area", "lighting_secondary_space_type": "Performing arts theater", "lighting_power_density": 1.16, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -564,7 +564,7 @@ "lighting_primary_space_type": "Audience Seating Area", "lighting_secondary_space_type": "Religious facility", "lighting_power_density": 0.72, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -578,7 +578,7 @@ "lighting_primary_space_type": "Audience Seating Area", "lighting_secondary_space_type": "Sports arena", "lighting_power_density": 0.33, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -592,7 +592,7 @@ "lighting_primary_space_type": "Audience Seating Area", "lighting_secondary_space_type": "All other audience seating areas", "lighting_power_density": 0.23, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -606,7 +606,7 @@ "lighting_primary_space_type": "Banking Activity Area", "lighting_secondary_space_type": "General", "lighting_power_density": 0.61, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -620,7 +620,7 @@ "lighting_primary_space_type": "Breakroom", "lighting_secondary_space_type": "General", "lighting_power_density": 0.59, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -634,7 +634,7 @@ "lighting_primary_space_type": "Classroom/Lecture Hall/Training Room", "lighting_secondary_space_type": "Penitentiary", "lighting_power_density": 0.89, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -648,7 +648,7 @@ "lighting_primary_space_type": "Classroom/Lecture Hall/Training Room", "lighting_secondary_space_type": "All other classrooms/lecture halls/training rooms", "lighting_power_density": 0.71, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -662,7 +662,7 @@ "lighting_primary_space_type": "Conference/Meeting/Multipurpose Room", "lighting_secondary_space_type": "General", "lighting_power_density": 0.97, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -676,7 +676,7 @@ "lighting_primary_space_type": "Confinement Cells", "lighting_secondary_space_type": "General", "lighting_power_density": 0.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -690,7 +690,7 @@ "lighting_primary_space_type": "Copy/Print Room", "lighting_secondary_space_type": "General", "lighting_power_density": 0.31, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -704,7 +704,7 @@ "lighting_primary_space_type": "Corridor", "lighting_secondary_space_type": "Facility for the visually impaired (and not used primarily by the staff)", "lighting_power_density": 0.71, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -718,7 +718,7 @@ "lighting_primary_space_type": "Corridor", "lighting_secondary_space_type": "Hospital", "lighting_power_density": 0.71, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -732,7 +732,7 @@ "lighting_primary_space_type": "Corridor", "lighting_secondary_space_type": "All other corridors", "lighting_power_density": 0.41, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -746,7 +746,7 @@ "lighting_primary_space_type": "Courtroom", "lighting_secondary_space_type": "General", "lighting_power_density": 1.2, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -760,7 +760,7 @@ "lighting_primary_space_type": "Computer Room", "lighting_secondary_space_type": "General", "lighting_power_density": 0.94, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -774,7 +774,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "Penitentiary", "lighting_power_density": 0.42, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -788,7 +788,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "Facility for the visually impaired (and not used primarily by staff)", "lighting_power_density": 1.27, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -802,7 +802,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "Bar/lounge or leisure dining", "lighting_power_density": 0.86, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -816,7 +816,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "Cafeteria or fast food dining", "lighting_power_density": 0.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -830,7 +830,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "Family dining", "lighting_power_density": 0.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -844,7 +844,7 @@ "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "All other dining areas", "lighting_power_density": 0.43, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -858,7 +858,7 @@ "lighting_primary_space_type": "Electrical/Mechanical Room", "lighting_secondary_space_type": "General", "lighting_power_density": 0.43, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -872,7 +872,7 @@ "lighting_primary_space_type": "Emergency Vehicle Garage", "lighting_secondary_space_type": "General", "lighting_power_density": 0.52, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -886,7 +886,7 @@ "lighting_primary_space_type": "Food Preparation Area", "lighting_secondary_space_type": "General", "lighting_power_density": 1.09, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -900,7 +900,7 @@ "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "General", "lighting_power_density": 0.41, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -914,7 +914,7 @@ "lighting_primary_space_type": "Laboratory", "lighting_secondary_space_type": "In or as a classroom", "lighting_power_density": 1.11, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -928,7 +928,7 @@ "lighting_primary_space_type": "Laboratory", "lighting_secondary_space_type": "All other laboratories", "lighting_power_density": 1.33, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -942,7 +942,7 @@ "lighting_primary_space_type": "Laundry/Washing Area", "lighting_secondary_space_type": "General", "lighting_power_density": 0.53, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -956,7 +956,7 @@ "lighting_primary_space_type": "Loading Dock, Interior", "lighting_secondary_space_type": "General", "lighting_power_density": 0.88, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -970,7 +970,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "Facility for the visually impaired (and not used primarily by the staff)", "lighting_power_density": 1.69, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -984,7 +984,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "Elevator", "lighting_power_density": 0.65, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -998,7 +998,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "Hotel", "lighting_power_density": 0.51, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1012,7 +1012,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "Motion picture theater", "lighting_power_density": 0.23, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1026,7 +1026,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "Performing arts theater ", "lighting_power_density": 1.25, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1040,7 +1040,7 @@ "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "All other lobbies", "lighting_power_density": 0.84, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1054,7 +1054,7 @@ "lighting_primary_space_type": "Locker Room", "lighting_secondary_space_type": "General", "lighting_power_density": 0.52, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1068,7 +1068,7 @@ "lighting_primary_space_type": "Lounge/Breakroom", "lighting_secondary_space_type": "Healthcare facility", "lighting_power_density": 0.42, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1082,7 +1082,7 @@ "lighting_primary_space_type": "Lounge/Breakroom", "lighting_secondary_space_type": "All other lounges/breakrooms", "lighting_power_density": 0.59, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1096,7 +1096,7 @@ "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "Enclosed and <= 250 ft2", "lighting_power_density": 0.74, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1110,7 +1110,7 @@ "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "Enclosed and > 250 ft2", "lighting_power_density": 0.66, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1124,7 +1124,7 @@ "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "Open plan", "lighting_power_density": 0.61, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1138,7 +1138,7 @@ "lighting_primary_space_type": "Parking Area, Interior", "lighting_secondary_space_type": "General", "lighting_power_density": 0.15, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1152,7 +1152,7 @@ "lighting_primary_space_type": "Pharmacy Area", "lighting_secondary_space_type": "General", "lighting_power_density": 1.66, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1166,7 +1166,7 @@ "lighting_primary_space_type": "Restroom", "lighting_secondary_space_type": "Facility for the visually impaired (and not used primarily by the staff)", "lighting_power_density": 1.26, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1180,7 +1180,7 @@ "lighting_primary_space_type": "Restroom", "lighting_secondary_space_type": "All other restrooms", "lighting_power_density": 0.63, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1194,7 +1194,7 @@ "lighting_primary_space_type": "Sales Area", "lighting_secondary_space_type": "General", "lighting_power_density": 1.05, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1208,7 +1208,7 @@ "lighting_primary_space_type": "Seating Area, General", "lighting_secondary_space_type": "General", "lighting_power_density": 0.23, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1222,7 +1222,7 @@ "lighting_primary_space_type": "Stairway", "lighting_secondary_space_type": "General", "lighting_power_density": 0.49, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 10, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1236,7 +1236,7 @@ "lighting_primary_space_type": "Stairwell", "lighting_secondary_space_type": "General", "lighting_power_density": 0.49, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 10, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1250,7 +1250,7 @@ "lighting_primary_space_type": "Storage Room", "lighting_secondary_space_type": "< 50 ft2", "lighting_power_density": 0.51, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 9, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1264,7 +1264,7 @@ "lighting_primary_space_type": "Storage Room", "lighting_secondary_space_type": ">= 50 ft2", "lighting_power_density": 0.38, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1278,7 +1278,7 @@ "lighting_primary_space_type": "Vehicular Maintenance Area", "lighting_secondary_space_type": "General", "lighting_power_density": 0.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1292,7 +1292,7 @@ "lighting_primary_space_type": "Workshop", "lighting_secondary_space_type": "General", "lighting_power_density": 1.26, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1306,7 +1306,7 @@ "lighting_primary_space_type": "Facility for the Visually Impaired", "lighting_secondary_space_type": "Chapel (used primarily by residents)", "lighting_power_density": 0.7, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1320,7 +1320,7 @@ "lighting_primary_space_type": "Facility for the Visually Impaired", "lighting_secondary_space_type": "Recreation room/common living room (and not used primarily by staff)", "lighting_power_density": 1.77, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1334,7 +1334,7 @@ "lighting_primary_space_type": "Automotive", "lighting_secondary_space_type": "General", "lighting_power_density": 0.6, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1348,7 +1348,7 @@ "lighting_primary_space_type": "Convention Center: Exhibit Space", "lighting_secondary_space_type": "General", "lighting_power_density": 0.61, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1362,7 +1362,7 @@ "lighting_primary_space_type": "Dormitory: Living Quarters", "lighting_secondary_space_type": "General", "lighting_power_density": 0.5, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1376,7 +1376,7 @@ "lighting_primary_space_type": "Fire Station: Sleeping Quarters", "lighting_secondary_space_type": "General", "lighting_power_density": 0.23, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1390,7 +1390,7 @@ "lighting_primary_space_type": "Gymnasium/Fitness Center", "lighting_secondary_space_type": "Exercise area", "lighting_power_density": 0.9, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1404,7 +1404,7 @@ "lighting_primary_space_type": "Gymnasium/Fitness Center", "lighting_secondary_space_type": "Playing area", "lighting_power_density": 0.85, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1418,7 +1418,7 @@ "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Exam/treatment room", "lighting_power_density": 1.4, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1432,7 +1432,7 @@ "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Imaging room", "lighting_power_density": 0.94, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1446,7 +1446,7 @@ "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Medical supply room", "lighting_power_density": 0.62, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1460,7 +1460,7 @@ "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Nursery", "lighting_power_density": 0.92, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1474,7 +1474,7 @@ "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Nurse's station", "lighting_power_density": 1.17, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1488,7 +1488,7 @@ "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Operating room", "lighting_power_density": 2.26, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, @@ -1502,7 +1502,7 @@ "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Patient room", "lighting_power_density": 0.68, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1516,7 +1516,7 @@ "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Physical therapy room", "lighting_power_density": 0.91, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1530,7 +1530,7 @@ "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Recovery room", "lighting_power_density": 1.25, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1544,7 +1544,7 @@ "lighting_primary_space_type": "Library", "lighting_secondary_space_type": "Reading area", "lighting_power_density": 0.96, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1558,7 +1558,7 @@ "lighting_primary_space_type": "Library", "lighting_secondary_space_type": "Stacks", "lighting_power_density": 1.18, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1572,7 +1572,7 @@ "lighting_primary_space_type": "Manufacturing Facility", "lighting_secondary_space_type": "Detailed manufacturing area", "lighting_power_density": 0.8, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1586,7 +1586,7 @@ "lighting_primary_space_type": "Manufacturing Facility", "lighting_secondary_space_type": "Equipment room", "lighting_power_density": 0.76, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1600,7 +1600,7 @@ "lighting_primary_space_type": "Manufacturing Facility", "lighting_secondary_space_type": "Extra high bay area (> 50 ft floor-to-ceiling height)", "lighting_power_density": 1.42, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1614,7 +1614,7 @@ "lighting_primary_space_type": "Manufacturing Facility", "lighting_secondary_space_type": "High bay area (25 to 50 ft floor-to-ceiling height)", "lighting_power_density": 1.24, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1628,7 +1628,7 @@ "lighting_primary_space_type": "Manufacturing Facility", "lighting_secondary_space_type": "Low bay area (< 25 ft floor-to-ceiling height)", "lighting_power_density": 0.86, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 3, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1642,7 +1642,7 @@ "lighting_primary_space_type": "Museum", "lighting_secondary_space_type": "General exhibition area", "lighting_power_density": 0.31, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1656,7 +1656,7 @@ "lighting_primary_space_type": "Museum", "lighting_secondary_space_type": "Restoration room", "lighting_power_density": 1.1, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1670,7 +1670,7 @@ "lighting_primary_space_type": "Performing Arts Theater: Dressing Room", "lighting_secondary_space_type": "General", "lighting_power_density": 0.41, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1684,7 +1684,7 @@ "lighting_primary_space_type": "Post Office: Sorting Area", "lighting_secondary_space_type": "General", "lighting_power_density": 0.76, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1698,7 +1698,7 @@ "lighting_primary_space_type": "Religious Facility", "lighting_secondary_space_type": "Fellowship hall", "lighting_power_density": 0.54, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1712,7 +1712,7 @@ "lighting_primary_space_type": "Religious Facility", "lighting_secondary_space_type": "Worship/pulpit/choir area", "lighting_power_density": 0.85, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1726,7 +1726,7 @@ "lighting_primary_space_type": "Retail Facilities", "lighting_secondary_space_type": "Dressing/fitting room", "lighting_power_density": 0.51, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1740,7 +1740,7 @@ "lighting_primary_space_type": "Retail Facilities", "lighting_secondary_space_type": "Mall concourse", "lighting_power_density": 0.82, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1754,7 +1754,7 @@ "lighting_primary_space_type": "Sports Arena: Playing Area", "lighting_secondary_space_type": "Class I facility", "lighting_power_density": 2.94, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1768,7 +1768,7 @@ "lighting_primary_space_type": "Sports Arena: Playing Area", "lighting_secondary_space_type": "Class II facility", "lighting_power_density": 2.01, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1782,7 +1782,7 @@ "lighting_primary_space_type": "Sports Arena: Playing Area", "lighting_secondary_space_type": "Class III facility", "lighting_power_density": 1.3, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1796,7 +1796,7 @@ "lighting_primary_space_type": "Sports Arena: Playing Area", "lighting_secondary_space_type": "Class IV facility", "lighting_power_density": 0.86, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1810,7 +1810,7 @@ "lighting_primary_space_type": "Transportation Facility", "lighting_secondary_space_type": "Baggage/carousel area", "lighting_power_density": 0.39, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1824,7 +1824,7 @@ "lighting_primary_space_type": "Transportation Facility", "lighting_secondary_space_type": "Airport concourse", "lighting_power_density": 0.25, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1838,7 +1838,7 @@ "lighting_primary_space_type": "Transportation Facility", "lighting_secondary_space_type": "Ticket counter", "lighting_power_density": 0.51, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1852,7 +1852,7 @@ "lighting_primary_space_type": "Warehouse: Storage Area", "lighting_secondary_space_type": "Medium to bulky, palletized items", "lighting_power_density": 0.33, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1866,7 +1866,7 @@ "lighting_primary_space_type": "Warehouse: Storage Area", "lighting_secondary_space_type": "Smaller, hand-carried items", "lighting_power_density": 0.69, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1880,7 +1880,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Sales Additional (Retail Area 1)", "lighting_power_density": 0.45, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1894,7 +1894,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Sales Additional (Retail Area 2)", "lighting_power_density": 0.45, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1908,7 +1908,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Sales Additional (Retail Area 3)", "lighting_power_density": 1.05, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1922,7 +1922,7 @@ "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Sales Additional (Retail Area 4)", "lighting_power_density": 1.88, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", @@ -1936,7 +1936,7 @@ "lighting_primary_space_type": "None", "lighting_secondary_space_type": "None", "lighting_power_density": 0, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, diff --git a/data/openstudio_standards_data/database_tables/envelope_requirement.py b/data/openstudio_standards_data/database_tables/envelope_requirement.py index e46a1556df..4eac381349 100644 --- a/data/openstudio_standards_data/database_tables/envelope_requirement.py +++ b/data/openstudio_standards_data/database_tables/envelope_requirement.py @@ -16,10 +16,13 @@ minimum_percent_of_surface: NUMERIC maximum_percent_of_surface: NUMERIC assembly_maximum_u_value: NUMERIC +assembly_maximum_u_value_unit: TEXT u_value_includes_interior_film_coefficient: TEXT u_value_includes_exterior_film_coefficient: TEXT assembly_maximum_f_factor: NUMERIC +assembly_maximum_f_factor_unit: TEXT assembly_maximum_c_factor: NUMERIC +assembly_maximum_c_factor_unit: TEXT assembly_maximum_solar_heat_gain_coefficient: NUMERIC assembly_minimum_vt_SHGC: NUMERIC annotation: TEXT (optional) @@ -38,10 +41,13 @@ minimum_percent_of_surface NUMERIC, maximum_percent_of_surface NUMERIC, assembly_maximum_u_value NUMERIC, +assembly_maximum_u_value_unit TEXT, u_value_includes_interior_film_coefficient TEXT, u_value_includes_exterior_film_coefficient TEXT, assembly_maximum_f_factor NUMERIC, +assembly_maximum_f_factor_unit TEXT, assembly_maximum_c_factor NUMERIC, +assembly_maximum_c_factor_unit TEXT, assembly_maximum_solar_heat_gain_coefficient NUMERIC, assembly_minimum_vt_shgc NUMERIC, annotation TEXT, @@ -61,15 +67,18 @@ minimum_percent_of_surface, maximum_percent_of_surface, assembly_maximum_u_value, +assembly_maximum_u_value_unit, u_value_includes_interior_film_coefficient, u_value_includes_exterior_film_coefficient, assembly_maximum_f_factor, +assembly_maximum_f_factor_unit, assembly_maximum_c_factor, +assembly_maximum_c_factor_unit, assembly_maximum_solar_heat_gain_coefficient, assembly_minimum_vt_shgc, annotation ) -VALUES (?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?); +VALUES (?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ? , ? , ?); """ RECORD_TEMPLATE = { @@ -83,10 +92,13 @@ "minimum_percent_of_surface": 0.0, "maximum_percent_of_surface": 0.0, "assembly_maximum_u_value": 0.0, + "assembly_maximum_u_value_unit": "btu/h-ft2-F", "u_value_includes_interior_film_coefficient": 0.0, "u_value_includes_exterior_film_coefficient": 0.0, "assembly_maximum_f_factor": 0.0, + "assembly_maximum_f_factor_unit": "btu/h-ft-F", "assembly_maximum_c_factor": 0.0, + "assembly_maximum_c_factor_unit": "btu/h-ft2-F", "assembly_maximum_solar_heat_gain_coefficient": 0.0, "assembly_minimum_vt_shgc": 0.0, "annotation": "", @@ -166,10 +178,13 @@ def _preprocess_record(self, record): getattr_either("minimum_percent_of_surface", record), getattr_either("maximum_percent_of_surface", record), getattr_either("assembly_maximum_u_value", record), + getattr_either("assembly_maximum_u_value_unit", record, "btu/h-ft2-F"), getattr_either("u_value_includes_interior_film_coefficient", record), getattr_either("u_value_includes_exterior_film_coefficient", record), getattr_either("assembly_maximum_f_factor", record), + getattr_either("assembly_maximum_f_factor_unit", record, "btu/h-ft-F"), getattr_either("assembly_maximum_c_factor", record), + getattr_either("assembly_maximum_c_factor_unit", record, "btu/h-ft2-F"), getattr_either("assembly_maximum_solar_heat_gain_coefficient", record), getattr_either("assembly_minimum_vt_shgc", record), getattr_either("annotation", record), diff --git a/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_definition.py b/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_definition.py index 070b12f375..d5e38fbb73 100644 --- a/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_definition.py +++ b/data/openstudio_standards_data/database_tables/level_3_lighting_90_1_definition.py @@ -9,7 +9,7 @@ lighting_primary_space_type: TEXT lighting_secondary_space_type: TEXT lighting_per_area: REAL -unit: TEXT +lighting_power_density_unit: TEXT rcr_threshold: NUMERIC automatic_daylight_responsive_controls_for_sidelighting: TEXT automatic_daylight_responsive_controls_for_toplighting: TEXT @@ -26,7 +26,7 @@ lighting_primary_space_type TEXT, lighting_secondary_space_type TEXT, lighting_power_density NUMERIC NOT NULL, -unit TEXT DEFAULT 'w/ft2' NOT NULL, +lighting_power_density_unit TEXT DEFAULT 'w/ft2' NOT NULL, rcr_threshold NUMERIC, automatic_daylight_responsive_controls_for_sidelighting TEXT, automatic_daylight_responsive_controls_for_toplighting TEXT, @@ -43,7 +43,7 @@ lighting_primary_space_type, lighting_secondary_space_type, lighting_power_density, - unit, + lighting_power_density_unit, rcr_threshold, automatic_daylight_responsive_controls_for_sidelighting, automatic_daylight_responsive_controls_for_toplighting, @@ -60,7 +60,7 @@ "lighting_primary_space_type": "", "lighting_secondary_space_type": "", "lighting_power_density": 0.0, - "unit": "W/ft2", + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 0.0, "automatic_daylight_responsive_controls_for_sidelighting": "", "automatic_daylight_responsive_controls_for_toplighting": "", @@ -112,7 +112,7 @@ def _preprocess_record(self, record): getattr_either("lighting_primary_space_type", record), getattr_either("lighting_secondary_space_type", record), getattr_either("lighting_power_density", record), - getattr_either("unit", record, "W/ft2"), + getattr_either("lighting_power_density_unit", record, "W/ft2"), getattr_either("rcr_threshold", record), getattr_either( "automatic_daylight_responsive_controls_for_sidelighting", record From 8c19415859b55baef10aee9e5c15083bc078e58d Mon Sep 17 00:00:00 2001 From: Weili Xu Date: Tue, 30 May 2023 16:27:53 -0700 Subject: [PATCH 29/45] update comments in database_table fetch function --- data/openstudio_standards_data/query/fetch/database_table.py | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/data/openstudio_standards_data/query/fetch/database_table.py b/data/openstudio_standards_data/query/fetch/database_table.py index 2df8745015..8e5b70592c 100644 --- a/data/openstudio_standards_data/query/fetch/database_table.py +++ b/data/openstudio_standards_data/query/fetch/database_table.py @@ -1,5 +1,5 @@ """ -This module fetches the lighting standards +This module contains functions that help to fetch data from tables """ import sqlite3 From 31a5d864c3471ef8bffd9e853a5e5c64f50d2ef3 Mon Sep 17 00:00:00 2001 From: Weili Xu Date: Wed, 31 May 2023 06:08:19 -0700 Subject: [PATCH 30/45] update level_2_lighting_space_types schema to add a unit field --- .../level_2_lighting_space_types.json | 708 ++++++++++++++++++ .../level_2_lighting_space_types.py | 7 +- 2 files changed, 714 insertions(+), 1 deletion(-) diff --git a/data/openstudio_standards_data/database_files/level_2_lighting_space_types.json b/data/openstudio_standards_data/database_files/level_2_lighting_space_types.json index 8364cbe8a9..4b2c3e6e39 100644 --- a/data/openstudio_standards_data/database_files/level_2_lighting_space_types.json +++ b/data/openstudio_standards_data/database_files/level_2_lighting_space_types.json @@ -5,6 +5,7 @@ "level_3_lighting_code_definition_id": 122, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -13,6 +14,7 @@ "level_3_lighting_code_definition_id": 36, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -21,6 +23,7 @@ "level_3_lighting_code_definition_id": 126, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 0, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -29,6 +32,7 @@ "level_3_lighting_code_definition_id": 46, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -37,6 +41,7 @@ "level_3_lighting_code_definition_id": 121, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -45,6 +50,7 @@ "level_3_lighting_code_definition_id": 77, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -53,6 +59,7 @@ "level_3_lighting_code_definition_id": 48, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 471, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -61,6 +68,7 @@ "level_3_lighting_code_definition_id": 48, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 710, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -69,6 +77,7 @@ "level_3_lighting_code_definition_id": 49, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -77,6 +86,7 @@ "level_3_lighting_code_definition_id": 79, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -85,6 +95,7 @@ "level_3_lighting_code_definition_id": 49, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -93,6 +104,7 @@ "level_3_lighting_code_definition_id": 52, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -101,6 +113,7 @@ "level_3_lighting_code_definition_id": 80, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -109,6 +122,7 @@ "level_3_lighting_code_definition_id": 60, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -117,6 +131,7 @@ "level_3_lighting_code_definition_id": 60, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -125,6 +140,7 @@ "level_3_lighting_code_definition_id": 58, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 308, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -133,6 +149,7 @@ "level_3_lighting_code_definition_id": 59, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -141,6 +158,7 @@ "level_3_lighting_code_definition_id": 60, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -149,6 +167,7 @@ "level_3_lighting_code_definition_id": 87, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 888, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -157,6 +176,7 @@ "level_3_lighting_code_definition_id": 83, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -165,6 +185,7 @@ "level_3_lighting_code_definition_id": 88, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -173,6 +194,7 @@ "level_3_lighting_code_definition_id": 85, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -181,6 +203,7 @@ "level_3_lighting_code_definition_id": 108, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 431, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -189,6 +212,7 @@ "level_3_lighting_code_definition_id": 99, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -197,6 +221,7 @@ "level_3_lighting_code_definition_id": 97, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -205,6 +230,7 @@ "level_3_lighting_code_definition_id": 110, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 54, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -213,6 +239,7 @@ "level_3_lighting_code_definition_id": 81, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -221,6 +248,7 @@ "level_3_lighting_code_definition_id": 61, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 538, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -229,6 +257,7 @@ "level_3_lighting_code_definition_id": 64, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -237,6 +266,7 @@ "level_3_lighting_code_definition_id": 89, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -245,6 +275,7 @@ "level_3_lighting_code_definition_id": 13, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -253,6 +284,7 @@ "level_3_lighting_code_definition_id": 82, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -261,6 +293,7 @@ "level_3_lighting_code_definition_id": 30, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -269,6 +302,7 @@ "level_3_lighting_code_definition_id": 68, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -277,6 +311,7 @@ "level_3_lighting_code_definition_id": 59, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -285,6 +320,7 @@ "level_3_lighting_code_definition_id": 70, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -293,6 +329,7 @@ "level_3_lighting_code_definition_id": 14, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -301,6 +338,7 @@ "level_3_lighting_code_definition_id": 90, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -309,6 +347,7 @@ "level_3_lighting_code_definition_id": 17, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -317,6 +356,7 @@ "level_3_lighting_code_definition_id": 92, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -325,6 +365,7 @@ "level_3_lighting_code_definition_id": 91, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -333,6 +374,7 @@ "level_3_lighting_code_definition_id": 19, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 414, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -341,6 +383,7 @@ "level_3_lighting_code_definition_id": 71, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -349,6 +392,7 @@ "level_3_lighting_code_definition_id": 93, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 1184, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -357,6 +401,7 @@ "level_3_lighting_code_definition_id": 94, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -365,6 +410,7 @@ "level_3_lighting_code_definition_id": 95, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 888, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -373,6 +419,7 @@ "level_3_lighting_code_definition_id": 96, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -381,6 +428,7 @@ "level_3_lighting_code_definition_id": 86, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -389,6 +437,7 @@ "level_3_lighting_code_definition_id": 24, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -397,6 +446,7 @@ "level_3_lighting_code_definition_id": 98, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -405,6 +455,7 @@ "level_3_lighting_code_definition_id": 70, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 323, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -413,6 +464,7 @@ "level_3_lighting_code_definition_id": 73, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -421,6 +473,7 @@ "level_3_lighting_code_definition_id": 117, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -429,6 +482,7 @@ "level_3_lighting_code_definition_id": 84, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 59, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -437,6 +491,7 @@ "level_3_lighting_code_definition_id": 28, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 1184, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -445,6 +500,7 @@ "level_3_lighting_code_definition_id": 74, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -453,6 +509,7 @@ "level_3_lighting_code_definition_id": 34, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -461,6 +518,7 @@ "level_3_lighting_code_definition_id": 30, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -469,6 +527,7 @@ "level_3_lighting_code_definition_id": 76, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -477,6 +536,7 @@ "level_3_lighting_code_definition_id": 32, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -485,6 +545,7 @@ "level_3_lighting_code_definition_id": 25, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -493,6 +554,7 @@ "level_3_lighting_code_definition_id": 1, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -501,6 +563,7 @@ "level_3_lighting_code_definition_id": 2, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -509,6 +572,7 @@ "level_3_lighting_code_definition_id": 3, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -517,6 +581,7 @@ "level_3_lighting_code_definition_id": 4, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -525,6 +590,7 @@ "level_3_lighting_code_definition_id": 5, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -533,6 +599,7 @@ "level_3_lighting_code_definition_id": 6, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -541,6 +608,7 @@ "level_3_lighting_code_definition_id": 7, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -549,6 +617,7 @@ "level_3_lighting_code_definition_id": 8, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -557,6 +626,7 @@ "level_3_lighting_code_definition_id": 23, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -565,6 +635,7 @@ "level_3_lighting_code_definition_id": 9, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -573,6 +644,7 @@ "level_3_lighting_code_definition_id": 10, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -581,6 +653,7 @@ "level_3_lighting_code_definition_id": 11, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -589,6 +662,7 @@ "level_3_lighting_code_definition_id": 12, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -597,6 +671,7 @@ "level_3_lighting_code_definition_id": 16, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -605,6 +680,7 @@ "level_3_lighting_code_definition_id": 18, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -613,6 +689,7 @@ "level_3_lighting_code_definition_id": 20, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 54, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -621,6 +698,7 @@ "level_3_lighting_code_definition_id": 21, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -629,6 +707,7 @@ "level_3_lighting_code_definition_id": 22, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 426, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -637,6 +716,7 @@ "level_3_lighting_code_definition_id": 23, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -645,6 +725,7 @@ "level_3_lighting_code_definition_id": 27, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 471, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -653,6 +734,7 @@ "level_3_lighting_code_definition_id": 29, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -661,6 +743,7 @@ "level_3_lighting_code_definition_id": 26, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -669,6 +752,7 @@ "level_3_lighting_code_definition_id": 31, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -677,6 +761,7 @@ "level_3_lighting_code_definition_id": 39, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -685,6 +770,7 @@ "level_3_lighting_code_definition_id": 40, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -693,6 +779,7 @@ "level_3_lighting_code_definition_id": 41, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -701,6 +788,7 @@ "level_3_lighting_code_definition_id": 42, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 426, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -709,6 +797,7 @@ "level_3_lighting_code_definition_id": 43, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -717,6 +806,7 @@ "level_3_lighting_code_definition_id": 44, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -725,6 +815,7 @@ "level_3_lighting_code_definition_id": 47, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 471, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -733,6 +824,7 @@ "level_3_lighting_code_definition_id": 50, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -741,6 +833,7 @@ "level_3_lighting_code_definition_id": 57, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -749,6 +842,7 @@ "level_3_lighting_code_definition_id": 4, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -757,6 +851,7 @@ "level_3_lighting_code_definition_id": 5, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -765,6 +860,7 @@ "level_3_lighting_code_definition_id": 54, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -773,6 +869,7 @@ "level_3_lighting_code_definition_id": 65, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -781,6 +878,7 @@ "level_3_lighting_code_definition_id": 66, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -789,6 +887,7 @@ "level_3_lighting_code_definition_id": 67, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -797,6 +896,7 @@ "level_3_lighting_code_definition_id": 69, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -805,6 +905,7 @@ "level_3_lighting_code_definition_id": 71, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -813,6 +914,7 @@ "level_3_lighting_code_definition_id": 72, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 414, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -821,6 +923,7 @@ "level_3_lighting_code_definition_id": 76, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -829,6 +932,7 @@ "level_3_lighting_code_definition_id": 78, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 431, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -837,6 +941,7 @@ "level_3_lighting_code_definition_id": 101, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -845,6 +950,7 @@ "level_3_lighting_code_definition_id": 102, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -853,6 +959,7 @@ "level_3_lighting_code_definition_id": 104, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -861,6 +968,7 @@ "level_3_lighting_code_definition_id": 105, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -869,6 +977,7 @@ "level_3_lighting_code_definition_id": 106, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -877,6 +986,7 @@ "level_3_lighting_code_definition_id": 107, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -885,6 +995,7 @@ "level_3_lighting_code_definition_id": 109, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -893,6 +1004,7 @@ "level_3_lighting_code_definition_id": 111, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -901,6 +1013,7 @@ "level_3_lighting_code_definition_id": 112, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -909,6 +1022,7 @@ "level_3_lighting_code_definition_id": 113, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -917,6 +1031,7 @@ "level_3_lighting_code_definition_id": 114, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 403, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -925,6 +1040,7 @@ "level_3_lighting_code_definition_id": 123, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -933,6 +1049,7 @@ "level_3_lighting_code_definition_id": 125, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -941,6 +1058,7 @@ "level_3_lighting_code_definition_id": 124, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -949,6 +1067,7 @@ "level_3_lighting_code_definition_id": 125, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -957,6 +1076,7 @@ "level_3_lighting_code_definition_id": 36, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -965,6 +1085,7 @@ "level_3_lighting_code_definition_id": 129, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 0, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -973,6 +1094,7 @@ "level_3_lighting_code_definition_id": 46, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -981,6 +1103,7 @@ "level_3_lighting_code_definition_id": 124, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -989,6 +1112,7 @@ "level_3_lighting_code_definition_id": 78, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -997,6 +1121,7 @@ "level_3_lighting_code_definition_id": 48, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 471, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1005,6 +1130,7 @@ "level_3_lighting_code_definition_id": 48, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 710, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1013,6 +1139,7 @@ "level_3_lighting_code_definition_id": 49, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1021,6 +1148,7 @@ "level_3_lighting_code_definition_id": 80, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1029,6 +1157,7 @@ "level_3_lighting_code_definition_id": 49, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1037,6 +1166,7 @@ "level_3_lighting_code_definition_id": 52, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1045,6 +1175,7 @@ "level_3_lighting_code_definition_id": 81, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1053,6 +1184,7 @@ "level_3_lighting_code_definition_id": 60, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1061,6 +1193,7 @@ "level_3_lighting_code_definition_id": 60, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1069,6 +1202,7 @@ "level_3_lighting_code_definition_id": 58, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 308, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1077,6 +1211,7 @@ "level_3_lighting_code_definition_id": 59, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1085,6 +1220,7 @@ "level_3_lighting_code_definition_id": 60, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1093,6 +1229,7 @@ "level_3_lighting_code_definition_id": 88, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 888, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1101,6 +1238,7 @@ "level_3_lighting_code_definition_id": 84, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1109,6 +1247,7 @@ "level_3_lighting_code_definition_id": 89, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1117,6 +1256,7 @@ "level_3_lighting_code_definition_id": 86, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1125,6 +1265,7 @@ "level_3_lighting_code_definition_id": 109, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 431, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1133,6 +1274,7 @@ "level_3_lighting_code_definition_id": 100, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1141,6 +1283,7 @@ "level_3_lighting_code_definition_id": 98, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1149,6 +1292,7 @@ "level_3_lighting_code_definition_id": 111, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 54, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1157,6 +1301,7 @@ "level_3_lighting_code_definition_id": 82, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1165,6 +1310,7 @@ "level_3_lighting_code_definition_id": 61, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 538, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1173,6 +1319,7 @@ "level_3_lighting_code_definition_id": 64, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1181,6 +1328,7 @@ "level_3_lighting_code_definition_id": 90, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1189,6 +1337,7 @@ "level_3_lighting_code_definition_id": 13, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1197,6 +1346,7 @@ "level_3_lighting_code_definition_id": 83, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1205,6 +1355,7 @@ "level_3_lighting_code_definition_id": 30, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1213,6 +1364,7 @@ "level_3_lighting_code_definition_id": 68, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1221,6 +1373,7 @@ "level_3_lighting_code_definition_id": 59, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1229,6 +1382,7 @@ "level_3_lighting_code_definition_id": 70, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1237,6 +1391,7 @@ "level_3_lighting_code_definition_id": 14, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1245,6 +1400,7 @@ "level_3_lighting_code_definition_id": 91, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1253,6 +1409,7 @@ "level_3_lighting_code_definition_id": 17, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1261,6 +1418,7 @@ "level_3_lighting_code_definition_id": 93, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1269,6 +1427,7 @@ "level_3_lighting_code_definition_id": 92, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1277,6 +1436,7 @@ "level_3_lighting_code_definition_id": 19, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 414, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1285,6 +1445,7 @@ "level_3_lighting_code_definition_id": 71, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1293,6 +1454,7 @@ "level_3_lighting_code_definition_id": 94, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 1184, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1301,6 +1463,7 @@ "level_3_lighting_code_definition_id": 95, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1309,6 +1472,7 @@ "level_3_lighting_code_definition_id": 96, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 888, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1317,6 +1481,7 @@ "level_3_lighting_code_definition_id": 97, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1325,6 +1490,7 @@ "level_3_lighting_code_definition_id": 87, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1333,6 +1499,7 @@ "level_3_lighting_code_definition_id": 24, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1341,6 +1508,7 @@ "level_3_lighting_code_definition_id": 99, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1349,6 +1517,7 @@ "level_3_lighting_code_definition_id": 70, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 323, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1357,6 +1526,7 @@ "level_3_lighting_code_definition_id": 73, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1365,6 +1535,7 @@ "level_3_lighting_code_definition_id": 120, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1373,6 +1544,7 @@ "level_3_lighting_code_definition_id": 85, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 59, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1381,6 +1553,7 @@ "level_3_lighting_code_definition_id": 28, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 1184, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1389,6 +1562,7 @@ "level_3_lighting_code_definition_id": 75, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1397,6 +1571,7 @@ "level_3_lighting_code_definition_id": 34, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1405,6 +1580,7 @@ "level_3_lighting_code_definition_id": 30, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1413,6 +1589,7 @@ "level_3_lighting_code_definition_id": 77, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1421,6 +1598,7 @@ "level_3_lighting_code_definition_id": 32, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1429,6 +1607,7 @@ "level_3_lighting_code_definition_id": 25, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1437,6 +1616,7 @@ "level_3_lighting_code_definition_id": 1, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1445,6 +1625,7 @@ "level_3_lighting_code_definition_id": 2, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1453,6 +1634,7 @@ "level_3_lighting_code_definition_id": 3, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1461,6 +1643,7 @@ "level_3_lighting_code_definition_id": 4, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1469,6 +1652,7 @@ "level_3_lighting_code_definition_id": 5, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1477,6 +1661,7 @@ "level_3_lighting_code_definition_id": 6, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1485,6 +1670,7 @@ "level_3_lighting_code_definition_id": 7, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1493,6 +1679,7 @@ "level_3_lighting_code_definition_id": 8, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1501,6 +1688,7 @@ "level_3_lighting_code_definition_id": 23, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1509,6 +1697,7 @@ "level_3_lighting_code_definition_id": 9, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1517,6 +1706,7 @@ "level_3_lighting_code_definition_id": 10, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1525,6 +1715,7 @@ "level_3_lighting_code_definition_id": 11, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1533,6 +1724,7 @@ "level_3_lighting_code_definition_id": 12, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1541,6 +1733,7 @@ "level_3_lighting_code_definition_id": 16, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1549,6 +1742,7 @@ "level_3_lighting_code_definition_id": 18, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1557,6 +1751,7 @@ "level_3_lighting_code_definition_id": 20, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 54, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1565,6 +1760,7 @@ "level_3_lighting_code_definition_id": 21, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1573,6 +1769,7 @@ "level_3_lighting_code_definition_id": 22, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 426, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1581,6 +1778,7 @@ "level_3_lighting_code_definition_id": 23, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1589,6 +1787,7 @@ "level_3_lighting_code_definition_id": 27, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 471, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1597,6 +1796,7 @@ "level_3_lighting_code_definition_id": 29, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1605,6 +1805,7 @@ "level_3_lighting_code_definition_id": 26, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1613,6 +1814,7 @@ "level_3_lighting_code_definition_id": 31, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1621,6 +1823,7 @@ "level_3_lighting_code_definition_id": 39, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1629,6 +1832,7 @@ "level_3_lighting_code_definition_id": 40, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1637,6 +1841,7 @@ "level_3_lighting_code_definition_id": 41, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1645,6 +1850,7 @@ "level_3_lighting_code_definition_id": 42, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 426, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1653,6 +1859,7 @@ "level_3_lighting_code_definition_id": 43, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1661,6 +1868,7 @@ "level_3_lighting_code_definition_id": 44, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1669,6 +1877,7 @@ "level_3_lighting_code_definition_id": 47, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 471, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1677,6 +1886,7 @@ "level_3_lighting_code_definition_id": 50, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1685,6 +1895,7 @@ "level_3_lighting_code_definition_id": 57, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1693,6 +1904,7 @@ "level_3_lighting_code_definition_id": 4, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1701,6 +1913,7 @@ "level_3_lighting_code_definition_id": 5, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1709,6 +1922,7 @@ "level_3_lighting_code_definition_id": 54, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1717,6 +1931,7 @@ "level_3_lighting_code_definition_id": 65, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1725,6 +1940,7 @@ "level_3_lighting_code_definition_id": 66, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1733,6 +1949,7 @@ "level_3_lighting_code_definition_id": 67, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1741,6 +1958,7 @@ "level_3_lighting_code_definition_id": 69, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1749,6 +1967,7 @@ "level_3_lighting_code_definition_id": 71, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1757,6 +1976,7 @@ "level_3_lighting_code_definition_id": 72, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 414, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1765,6 +1985,7 @@ "level_3_lighting_code_definition_id": 77, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1773,6 +1994,7 @@ "level_3_lighting_code_definition_id": 79, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 431, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1781,6 +2003,7 @@ "level_3_lighting_code_definition_id": 102, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1789,6 +2012,7 @@ "level_3_lighting_code_definition_id": 103, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1797,6 +2021,7 @@ "level_3_lighting_code_definition_id": 105, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1805,6 +2030,7 @@ "level_3_lighting_code_definition_id": 106, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1813,6 +2039,7 @@ "level_3_lighting_code_definition_id": 107, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1821,6 +2048,7 @@ "level_3_lighting_code_definition_id": 108, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1829,6 +2057,7 @@ "level_3_lighting_code_definition_id": 110, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1837,6 +2066,7 @@ "level_3_lighting_code_definition_id": 112, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1845,6 +2075,7 @@ "level_3_lighting_code_definition_id": 113, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1853,6 +2084,7 @@ "level_3_lighting_code_definition_id": 114, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1861,6 +2093,7 @@ "level_3_lighting_code_definition_id": 115, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 403, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1869,6 +2102,7 @@ "level_3_lighting_code_definition_id": 126, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1877,6 +2111,7 @@ "level_3_lighting_code_definition_id": 128, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1885,6 +2120,7 @@ "level_3_lighting_code_definition_id": 127, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1893,6 +2129,7 @@ "level_3_lighting_code_definition_id": 128, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1901,6 +2138,7 @@ "level_3_lighting_code_definition_id": 34, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1909,6 +2147,7 @@ "level_3_lighting_code_definition_id": 133, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 0, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1917,6 +2156,7 @@ "level_3_lighting_code_definition_id": 36, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1925,6 +2165,7 @@ "level_3_lighting_code_definition_id": 127, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1933,6 +2174,7 @@ "level_3_lighting_code_definition_id": 64, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1941,6 +2183,7 @@ "level_3_lighting_code_definition_id": 39, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 471, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1949,6 +2192,7 @@ "level_3_lighting_code_definition_id": 39, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 710, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1957,6 +2201,7 @@ "level_3_lighting_code_definition_id": 40, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1965,6 +2210,7 @@ "level_3_lighting_code_definition_id": 67, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1973,6 +2219,7 @@ "level_3_lighting_code_definition_id": 40, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1981,6 +2228,7 @@ "level_3_lighting_code_definition_id": 41, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1989,6 +2237,7 @@ "level_3_lighting_code_definition_id": 68, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -1997,6 +2246,7 @@ "level_3_lighting_code_definition_id": 46, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2005,6 +2255,7 @@ "level_3_lighting_code_definition_id": 46, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2013,6 +2264,7 @@ "level_3_lighting_code_definition_id": 44, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 308, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2021,6 +2273,7 @@ "level_3_lighting_code_definition_id": 113, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2029,6 +2282,7 @@ "level_3_lighting_code_definition_id": 46, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2037,6 +2291,7 @@ "level_3_lighting_code_definition_id": 80, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 888, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2045,6 +2300,7 @@ "level_3_lighting_code_definition_id": 74, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2053,6 +2309,7 @@ "level_3_lighting_code_definition_id": 81, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2061,6 +2318,7 @@ "level_3_lighting_code_definition_id": 76, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2069,6 +2327,7 @@ "level_3_lighting_code_definition_id": 107, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 431, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2077,6 +2336,7 @@ "level_3_lighting_code_definition_id": 96, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2085,6 +2345,7 @@ "level_3_lighting_code_definition_id": 91, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2093,6 +2354,7 @@ "level_3_lighting_code_definition_id": 109, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 54, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2101,6 +2363,7 @@ "level_3_lighting_code_definition_id": 69, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2109,6 +2372,7 @@ "level_3_lighting_code_definition_id": 47, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 538, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2117,6 +2381,7 @@ "level_3_lighting_code_definition_id": 49, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2125,6 +2390,7 @@ "level_3_lighting_code_definition_id": 82, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2133,6 +2399,7 @@ "level_3_lighting_code_definition_id": 14, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2141,6 +2408,7 @@ "level_3_lighting_code_definition_id": 73, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2149,6 +2417,7 @@ "level_3_lighting_code_definition_id": 31, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2157,6 +2426,7 @@ "level_3_lighting_code_definition_id": 53, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2165,6 +2435,7 @@ "level_3_lighting_code_definition_id": 54, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2173,6 +2444,7 @@ "level_3_lighting_code_definition_id": 55, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2181,6 +2453,7 @@ "level_3_lighting_code_definition_id": 15, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2189,6 +2462,7 @@ "level_3_lighting_code_definition_id": 84, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2197,6 +2471,7 @@ "level_3_lighting_code_definition_id": 18, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2205,6 +2480,7 @@ "level_3_lighting_code_definition_id": 85, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2213,6 +2489,7 @@ "level_3_lighting_code_definition_id": 86, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2221,6 +2498,7 @@ "level_3_lighting_code_definition_id": 20, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 414, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2229,6 +2507,7 @@ "level_3_lighting_code_definition_id": 56, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2237,6 +2516,7 @@ "level_3_lighting_code_definition_id": 87, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 1184, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2245,6 +2525,7 @@ "level_3_lighting_code_definition_id": 88, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2253,6 +2534,7 @@ "level_3_lighting_code_definition_id": 89, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 888, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2261,6 +2543,7 @@ "level_3_lighting_code_definition_id": 90, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2269,6 +2552,7 @@ "level_3_lighting_code_definition_id": 78, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2277,6 +2561,7 @@ "level_3_lighting_code_definition_id": 25, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2285,6 +2570,7 @@ "level_3_lighting_code_definition_id": 92, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2293,6 +2579,7 @@ "level_3_lighting_code_definition_id": 55, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 323, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2301,6 +2588,7 @@ "level_3_lighting_code_definition_id": 58, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2309,6 +2597,7 @@ "level_3_lighting_code_definition_id": 119, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2317,6 +2606,7 @@ "level_3_lighting_code_definition_id": 75, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 59, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2325,6 +2615,7 @@ "level_3_lighting_code_definition_id": 29, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 1184, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2333,6 +2624,7 @@ "level_3_lighting_code_definition_id": 60, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2341,6 +2633,7 @@ "level_3_lighting_code_definition_id": 61, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2349,6 +2642,7 @@ "level_3_lighting_code_definition_id": 31, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2357,6 +2651,7 @@ "level_3_lighting_code_definition_id": 63, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2365,6 +2660,7 @@ "level_3_lighting_code_definition_id": 33, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2373,6 +2669,7 @@ "level_3_lighting_code_definition_id": 26, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2381,6 +2678,7 @@ "level_3_lighting_code_definition_id": 1, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2389,6 +2687,7 @@ "level_3_lighting_code_definition_id": 2, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2397,6 +2696,7 @@ "level_3_lighting_code_definition_id": 3, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2405,6 +2705,7 @@ "level_3_lighting_code_definition_id": 4, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2413,6 +2714,7 @@ "level_3_lighting_code_definition_id": 5, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2421,6 +2723,7 @@ "level_3_lighting_code_definition_id": 6, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2429,6 +2732,7 @@ "level_3_lighting_code_definition_id": 7, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2437,6 +2741,7 @@ "level_3_lighting_code_definition_id": 8, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2445,6 +2750,7 @@ "level_3_lighting_code_definition_id": 9, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2453,6 +2759,7 @@ "level_3_lighting_code_definition_id": 10, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2461,6 +2768,7 @@ "level_3_lighting_code_definition_id": 11, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2469,6 +2777,7 @@ "level_3_lighting_code_definition_id": 12, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2477,6 +2786,7 @@ "level_3_lighting_code_definition_id": 13, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2485,6 +2795,7 @@ "level_3_lighting_code_definition_id": 17, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2493,6 +2804,7 @@ "level_3_lighting_code_definition_id": 19, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2501,6 +2813,7 @@ "level_3_lighting_code_definition_id": 21, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 54, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2509,6 +2822,7 @@ "level_3_lighting_code_definition_id": 22, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2517,6 +2831,7 @@ "level_3_lighting_code_definition_id": 23, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 426, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2525,6 +2840,7 @@ "level_3_lighting_code_definition_id": 24, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2533,6 +2849,7 @@ "level_3_lighting_code_definition_id": 28, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 471, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2541,6 +2858,7 @@ "level_3_lighting_code_definition_id": 30, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2549,6 +2867,7 @@ "level_3_lighting_code_definition_id": 27, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2557,6 +2876,7 @@ "level_3_lighting_code_definition_id": 32, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2565,6 +2885,7 @@ "level_3_lighting_code_definition_id": 77, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2573,6 +2894,7 @@ "level_3_lighting_code_definition_id": 37, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2581,6 +2903,7 @@ "level_3_lighting_code_definition_id": 70, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2589,6 +2912,7 @@ "level_3_lighting_code_definition_id": 38, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 426, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2597,6 +2921,7 @@ "level_3_lighting_code_definition_id": 110, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2605,6 +2930,7 @@ "level_3_lighting_code_definition_id": 120, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2613,6 +2939,7 @@ "level_3_lighting_code_definition_id": 71, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 471, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2621,6 +2948,7 @@ "level_3_lighting_code_definition_id": 79, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2629,6 +2957,7 @@ "level_3_lighting_code_definition_id": 72, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2637,6 +2966,7 @@ "level_3_lighting_code_definition_id": 4, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2645,6 +2975,7 @@ "level_3_lighting_code_definition_id": 5, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2653,6 +2984,7 @@ "level_3_lighting_code_definition_id": 43, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2661,6 +2993,7 @@ "level_3_lighting_code_definition_id": 97, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2669,6 +3002,7 @@ "level_3_lighting_code_definition_id": 51, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2677,6 +3011,7 @@ "level_3_lighting_code_definition_id": 52, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2685,6 +3020,7 @@ "level_3_lighting_code_definition_id": 83, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2693,6 +3029,7 @@ "level_3_lighting_code_definition_id": 56, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2701,6 +3038,7 @@ "level_3_lighting_code_definition_id": 57, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 414, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2709,6 +3047,7 @@ "level_3_lighting_code_definition_id": 63, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2717,6 +3056,7 @@ "level_3_lighting_code_definition_id": 66, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 431, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2725,6 +3065,7 @@ "level_3_lighting_code_definition_id": 99, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2733,6 +3074,7 @@ "level_3_lighting_code_definition_id": 100, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2741,6 +3083,7 @@ "level_3_lighting_code_definition_id": 102, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2749,6 +3092,7 @@ "level_3_lighting_code_definition_id": 103, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2757,6 +3101,7 @@ "level_3_lighting_code_definition_id": 105, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2765,6 +3110,7 @@ "level_3_lighting_code_definition_id": 106, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2773,6 +3119,7 @@ "level_3_lighting_code_definition_id": 108, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2781,6 +3128,7 @@ "level_3_lighting_code_definition_id": 126, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2789,6 +3137,7 @@ "level_3_lighting_code_definition_id": 111, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2797,6 +3146,7 @@ "level_3_lighting_code_definition_id": 112, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2805,6 +3155,7 @@ "level_3_lighting_code_definition_id": 114, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 403, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2813,6 +3164,7 @@ "level_3_lighting_code_definition_id": 130, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2821,6 +3173,7 @@ "level_3_lighting_code_definition_id": 132, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2829,6 +3182,7 @@ "level_3_lighting_code_definition_id": 131, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2837,6 +3191,7 @@ "level_3_lighting_code_definition_id": 140, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2845,6 +3200,7 @@ "level_3_lighting_code_definition_id": 33, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2853,6 +3209,7 @@ "level_3_lighting_code_definition_id": 143, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 0, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2861,6 +3218,7 @@ "level_3_lighting_code_definition_id": 36, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2869,6 +3227,7 @@ "level_3_lighting_code_definition_id": 139, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2877,6 +3236,7 @@ "level_3_lighting_code_definition_id": 45, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2885,6 +3245,7 @@ "level_3_lighting_code_definition_id": 47, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 471, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2893,6 +3254,7 @@ "level_3_lighting_code_definition_id": 49, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 710, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2901,6 +3263,7 @@ "level_3_lighting_code_definition_id": 50, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2909,6 +3272,7 @@ "level_3_lighting_code_definition_id": 51, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2917,6 +3281,7 @@ "level_3_lighting_code_definition_id": 52, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2925,6 +3290,7 @@ "level_3_lighting_code_definition_id": 53, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2933,6 +3299,7 @@ "level_3_lighting_code_definition_id": 57, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2941,6 +3308,7 @@ "level_3_lighting_code_definition_id": 64, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2949,6 +3317,7 @@ "level_3_lighting_code_definition_id": 64, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2957,6 +3326,7 @@ "level_3_lighting_code_definition_id": 58, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 308, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2965,6 +3335,7 @@ "level_3_lighting_code_definition_id": 128, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2973,6 +3344,7 @@ "level_3_lighting_code_definition_id": 64, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2981,6 +3353,7 @@ "level_3_lighting_code_definition_id": 112, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 888, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2989,6 +3362,7 @@ "level_3_lighting_code_definition_id": 65, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -2997,6 +3371,7 @@ "level_3_lighting_code_definition_id": 112, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3005,6 +3380,7 @@ "level_3_lighting_code_definition_id": 105, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3013,6 +3389,7 @@ "level_3_lighting_code_definition_id": 122, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 431, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3021,6 +3398,7 @@ "level_3_lighting_code_definition_id": 67, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3029,6 +3407,7 @@ "level_3_lighting_code_definition_id": 113, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3037,6 +3416,7 @@ "level_3_lighting_code_definition_id": 84, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 54, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3045,6 +3425,7 @@ "level_3_lighting_code_definition_id": 57, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3053,6 +3434,7 @@ "level_3_lighting_code_definition_id": 66, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 538, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3061,6 +3443,7 @@ "level_3_lighting_code_definition_id": 68, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3069,6 +3452,7 @@ "level_3_lighting_code_definition_id": 70, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3077,6 +3461,7 @@ "level_3_lighting_code_definition_id": 14, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3085,6 +3470,7 @@ "level_3_lighting_code_definition_id": 99, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3093,6 +3479,7 @@ "level_3_lighting_code_definition_id": 71, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3101,6 +3488,7 @@ "level_3_lighting_code_definition_id": 72, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3109,6 +3497,7 @@ "level_3_lighting_code_definition_id": 78, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3117,6 +3506,7 @@ "level_3_lighting_code_definition_id": 46, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3125,6 +3515,7 @@ "level_3_lighting_code_definition_id": 15, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3133,6 +3524,7 @@ "level_3_lighting_code_definition_id": 106, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3141,6 +3533,7 @@ "level_3_lighting_code_definition_id": 17, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3149,6 +3542,7 @@ "level_3_lighting_code_definition_id": 108, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3157,6 +3551,7 @@ "level_3_lighting_code_definition_id": 107, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3165,6 +3560,7 @@ "level_3_lighting_code_definition_id": 19, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 414, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3173,6 +3569,7 @@ "level_3_lighting_code_definition_id": 81, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3181,6 +3578,7 @@ "level_3_lighting_code_definition_id": 114, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 1184, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3189,6 +3587,7 @@ "level_3_lighting_code_definition_id": 109, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3197,6 +3596,7 @@ "level_3_lighting_code_definition_id": 106, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 888, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3205,6 +3605,7 @@ "level_3_lighting_code_definition_id": 110, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3213,6 +3614,7 @@ "level_3_lighting_code_definition_id": 104, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3221,6 +3623,7 @@ "level_3_lighting_code_definition_id": 24, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3229,6 +3632,7 @@ "level_3_lighting_code_definition_id": 111, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3237,6 +3641,7 @@ "level_3_lighting_code_definition_id": 79, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 323, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3245,6 +3650,7 @@ "level_3_lighting_code_definition_id": 86, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3253,6 +3659,7 @@ "level_3_lighting_code_definition_id": 88, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3261,6 +3668,7 @@ "level_3_lighting_code_definition_id": 103, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 59, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3269,6 +3677,7 @@ "level_3_lighting_code_definition_id": 28, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 1184, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3277,6 +3686,7 @@ "level_3_lighting_code_definition_id": 91, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3285,6 +3695,7 @@ "level_3_lighting_code_definition_id": 94, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3293,6 +3704,7 @@ "level_3_lighting_code_definition_id": 30, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3301,6 +3713,7 @@ "level_3_lighting_code_definition_id": 95, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3309,6 +3722,7 @@ "level_3_lighting_code_definition_id": 32, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3317,6 +3731,7 @@ "level_3_lighting_code_definition_id": 25, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3325,6 +3740,7 @@ "level_3_lighting_code_definition_id": 1, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3333,6 +3749,7 @@ "level_3_lighting_code_definition_id": 2, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3341,6 +3758,7 @@ "level_3_lighting_code_definition_id": 3, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3349,6 +3767,7 @@ "level_3_lighting_code_definition_id": 4, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3357,6 +3776,7 @@ "level_3_lighting_code_definition_id": 5, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3365,6 +3785,7 @@ "level_3_lighting_code_definition_id": 6, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3373,6 +3794,7 @@ "level_3_lighting_code_definition_id": 7, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3381,6 +3803,7 @@ "level_3_lighting_code_definition_id": 8, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3389,6 +3812,7 @@ "level_3_lighting_code_definition_id": 9, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3397,6 +3821,7 @@ "level_3_lighting_code_definition_id": 10, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3405,6 +3830,7 @@ "level_3_lighting_code_definition_id": 11, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3413,6 +3839,7 @@ "level_3_lighting_code_definition_id": 12, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3421,6 +3848,7 @@ "level_3_lighting_code_definition_id": 13, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3429,6 +3857,7 @@ "level_3_lighting_code_definition_id": 16, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3437,6 +3866,7 @@ "level_3_lighting_code_definition_id": 18, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3445,6 +3875,7 @@ "level_3_lighting_code_definition_id": 20, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 54, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3453,6 +3884,7 @@ "level_3_lighting_code_definition_id": 21, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3461,6 +3893,7 @@ "level_3_lighting_code_definition_id": 22, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 426, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3469,6 +3902,7 @@ "level_3_lighting_code_definition_id": 23, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3477,6 +3911,7 @@ "level_3_lighting_code_definition_id": 27, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 471, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3485,6 +3920,7 @@ "level_3_lighting_code_definition_id": 29, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3493,6 +3929,7 @@ "level_3_lighting_code_definition_id": 26, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3501,6 +3938,7 @@ "level_3_lighting_code_definition_id": 31, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3509,6 +3947,7 @@ "level_3_lighting_code_definition_id": 38, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3517,6 +3956,7 @@ "level_3_lighting_code_definition_id": 39, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3525,6 +3965,7 @@ "level_3_lighting_code_definition_id": 40, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3533,6 +3974,7 @@ "level_3_lighting_code_definition_id": 41, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 426, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3541,6 +3983,7 @@ "level_3_lighting_code_definition_id": 42, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3549,6 +3992,7 @@ "level_3_lighting_code_definition_id": 43, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3557,6 +4001,7 @@ "level_3_lighting_code_definition_id": 48, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 471, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3565,6 +4010,7 @@ "level_3_lighting_code_definition_id": 55, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3573,6 +4019,7 @@ "level_3_lighting_code_definition_id": 60, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3581,6 +4028,7 @@ "level_3_lighting_code_definition_id": 4, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3589,6 +4037,7 @@ "level_3_lighting_code_definition_id": 5, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3597,6 +4046,7 @@ "level_3_lighting_code_definition_id": 63, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3605,6 +4055,7 @@ "level_3_lighting_code_definition_id": 75, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3613,6 +4064,7 @@ "level_3_lighting_code_definition_id": 76, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3621,6 +4073,7 @@ "level_3_lighting_code_definition_id": 77, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3629,6 +4082,7 @@ "level_3_lighting_code_definition_id": 80, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3637,6 +4091,7 @@ "level_3_lighting_code_definition_id": 81, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3645,6 +4100,7 @@ "level_3_lighting_code_definition_id": 83, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 414, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3653,6 +4109,7 @@ "level_3_lighting_code_definition_id": 97, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3661,6 +4118,7 @@ "level_3_lighting_code_definition_id": 98, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 431, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3669,6 +4127,7 @@ "level_3_lighting_code_definition_id": 115, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3677,6 +4136,7 @@ "level_3_lighting_code_definition_id": 116, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3685,6 +4145,7 @@ "level_3_lighting_code_definition_id": 117, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3693,6 +4154,7 @@ "level_3_lighting_code_definition_id": 120, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3701,6 +4163,7 @@ "level_3_lighting_code_definition_id": 118, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3709,6 +4172,7 @@ "level_3_lighting_code_definition_id": 119, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3717,6 +4181,7 @@ "level_3_lighting_code_definition_id": 123, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3725,6 +4190,7 @@ "level_3_lighting_code_definition_id": 125, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3733,6 +4199,7 @@ "level_3_lighting_code_definition_id": 127, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3741,6 +4208,7 @@ "level_3_lighting_code_definition_id": 126, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3749,6 +4217,7 @@ "level_3_lighting_code_definition_id": 129, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 403, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3757,6 +4226,7 @@ "level_3_lighting_code_definition_id": 138, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3765,6 +4235,7 @@ "level_3_lighting_code_definition_id": 141, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3773,6 +4244,7 @@ "level_3_lighting_code_definition_id": 142, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3781,6 +4253,7 @@ "level_3_lighting_code_definition_id": 137, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3789,6 +4262,7 @@ "level_3_lighting_code_definition_id": 33, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3797,6 +4271,7 @@ "level_3_lighting_code_definition_id": 142, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 0, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3805,6 +4280,7 @@ "level_3_lighting_code_definition_id": 36, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3813,6 +4289,7 @@ "level_3_lighting_code_definition_id": 138, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3821,6 +4298,7 @@ "level_3_lighting_code_definition_id": 45, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3829,6 +4307,7 @@ "level_3_lighting_code_definition_id": 47, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 471, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3837,6 +4316,7 @@ "level_3_lighting_code_definition_id": 49, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 710, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3845,6 +4325,7 @@ "level_3_lighting_code_definition_id": 50, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3853,6 +4334,7 @@ "level_3_lighting_code_definition_id": 51, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3861,6 +4343,7 @@ "level_3_lighting_code_definition_id": 52, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3869,6 +4352,7 @@ "level_3_lighting_code_definition_id": 53, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3877,6 +4361,7 @@ "level_3_lighting_code_definition_id": 57, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3885,6 +4370,7 @@ "level_3_lighting_code_definition_id": 64, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3893,6 +4379,7 @@ "level_3_lighting_code_definition_id": 64, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3901,6 +4388,7 @@ "level_3_lighting_code_definition_id": 58, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 308, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3909,6 +4397,7 @@ "level_3_lighting_code_definition_id": 127, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3917,6 +4406,7 @@ "level_3_lighting_code_definition_id": 64, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3925,6 +4415,7 @@ "level_3_lighting_code_definition_id": 105, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 888, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3933,6 +4424,7 @@ "level_3_lighting_code_definition_id": 65, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3941,6 +4433,7 @@ "level_3_lighting_code_definition_id": 105, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3949,6 +4442,7 @@ "level_3_lighting_code_definition_id": 103, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3957,6 +4451,7 @@ "level_3_lighting_code_definition_id": 121, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 431, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3965,6 +4460,7 @@ "level_3_lighting_code_definition_id": 67, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3973,6 +4469,7 @@ "level_3_lighting_code_definition_id": 106, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3981,6 +4478,7 @@ "level_3_lighting_code_definition_id": 84, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 54, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3989,6 +4487,7 @@ "level_3_lighting_code_definition_id": 57, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -3997,6 +4496,7 @@ "level_3_lighting_code_definition_id": 66, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 538, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4005,6 +4505,7 @@ "level_3_lighting_code_definition_id": 68, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4013,6 +4514,7 @@ "level_3_lighting_code_definition_id": 70, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4021,6 +4523,7 @@ "level_3_lighting_code_definition_id": 14, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4029,6 +4532,7 @@ "level_3_lighting_code_definition_id": 99, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4037,6 +4541,7 @@ "level_3_lighting_code_definition_id": 71, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4045,6 +4550,7 @@ "level_3_lighting_code_definition_id": 72, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4053,6 +4559,7 @@ "level_3_lighting_code_definition_id": 78, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4061,6 +4568,7 @@ "level_3_lighting_code_definition_id": 46, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4069,6 +4577,7 @@ "level_3_lighting_code_definition_id": 15, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4077,6 +4586,7 @@ "level_3_lighting_code_definition_id": 107, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4085,6 +4595,7 @@ "level_3_lighting_code_definition_id": 17, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4093,6 +4604,7 @@ "level_3_lighting_code_definition_id": 109, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4101,6 +4613,7 @@ "level_3_lighting_code_definition_id": 108, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4109,6 +4622,7 @@ "level_3_lighting_code_definition_id": 19, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 414, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4117,6 +4631,7 @@ "level_3_lighting_code_definition_id": 81, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4125,6 +4640,7 @@ "level_3_lighting_code_definition_id": 110, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 1184, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4133,6 +4649,7 @@ "level_3_lighting_code_definition_id": 111, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4141,6 +4658,7 @@ "level_3_lighting_code_definition_id": 107, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 888, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4149,6 +4667,7 @@ "level_3_lighting_code_definition_id": 112, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4157,6 +4676,7 @@ "level_3_lighting_code_definition_id": 104, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4165,6 +4685,7 @@ "level_3_lighting_code_definition_id": 24, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4173,6 +4694,7 @@ "level_3_lighting_code_definition_id": 113, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4181,6 +4703,7 @@ "level_3_lighting_code_definition_id": 79, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 323, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4189,6 +4712,7 @@ "level_3_lighting_code_definition_id": 86, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4197,6 +4721,7 @@ "level_3_lighting_code_definition_id": 88, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4205,6 +4730,7 @@ "level_3_lighting_code_definition_id": 102, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 59, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4213,6 +4739,7 @@ "level_3_lighting_code_definition_id": 28, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 1184, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4221,6 +4748,7 @@ "level_3_lighting_code_definition_id": 91, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4229,6 +4757,7 @@ "level_3_lighting_code_definition_id": 94, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4237,6 +4766,7 @@ "level_3_lighting_code_definition_id": 30, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4245,6 +4775,7 @@ "level_3_lighting_code_definition_id": 95, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4253,6 +4784,7 @@ "level_3_lighting_code_definition_id": 32, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4261,6 +4793,7 @@ "level_3_lighting_code_definition_id": 25, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4269,6 +4802,7 @@ "level_3_lighting_code_definition_id": 1, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4277,6 +4811,7 @@ "level_3_lighting_code_definition_id": 2, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4285,6 +4820,7 @@ "level_3_lighting_code_definition_id": 3, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4293,6 +4829,7 @@ "level_3_lighting_code_definition_id": 4, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4301,6 +4838,7 @@ "level_3_lighting_code_definition_id": 5, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4309,6 +4847,7 @@ "level_3_lighting_code_definition_id": 6, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4317,6 +4856,7 @@ "level_3_lighting_code_definition_id": 7, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4325,6 +4865,7 @@ "level_3_lighting_code_definition_id": 8, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4333,6 +4874,7 @@ "level_3_lighting_code_definition_id": 9, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4341,6 +4883,7 @@ "level_3_lighting_code_definition_id": 10, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4349,6 +4892,7 @@ "level_3_lighting_code_definition_id": 11, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4357,6 +4901,7 @@ "level_3_lighting_code_definition_id": 12, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4365,6 +4910,7 @@ "level_3_lighting_code_definition_id": 13, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4373,6 +4919,7 @@ "level_3_lighting_code_definition_id": 16, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4381,6 +4928,7 @@ "level_3_lighting_code_definition_id": 18, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4389,6 +4937,7 @@ "level_3_lighting_code_definition_id": 20, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 54, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4397,6 +4946,7 @@ "level_3_lighting_code_definition_id": 21, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4405,6 +4955,7 @@ "level_3_lighting_code_definition_id": 22, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 426, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4413,6 +4964,7 @@ "level_3_lighting_code_definition_id": 23, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4421,6 +4973,7 @@ "level_3_lighting_code_definition_id": 27, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 471, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4429,6 +4982,7 @@ "level_3_lighting_code_definition_id": 29, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4437,6 +4991,7 @@ "level_3_lighting_code_definition_id": 26, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4445,6 +5000,7 @@ "level_3_lighting_code_definition_id": 31, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4453,6 +5009,7 @@ "level_3_lighting_code_definition_id": 39, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4461,6 +5018,7 @@ "level_3_lighting_code_definition_id": 40, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4469,6 +5027,7 @@ "level_3_lighting_code_definition_id": 41, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4477,6 +5036,7 @@ "level_3_lighting_code_definition_id": 42, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 426, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4485,6 +5045,7 @@ "level_3_lighting_code_definition_id": 43, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4493,6 +5054,7 @@ "level_3_lighting_code_definition_id": 44, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4501,6 +5063,7 @@ "level_3_lighting_code_definition_id": 48, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 471, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4509,6 +5072,7 @@ "level_3_lighting_code_definition_id": 55, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4517,6 +5081,7 @@ "level_3_lighting_code_definition_id": 61, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4525,6 +5090,7 @@ "level_3_lighting_code_definition_id": 4, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4533,6 +5099,7 @@ "level_3_lighting_code_definition_id": 5, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4541,6 +5108,7 @@ "level_3_lighting_code_definition_id": 62, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4549,6 +5117,7 @@ "level_3_lighting_code_definition_id": 75, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4557,6 +5126,7 @@ "level_3_lighting_code_definition_id": 76, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4565,6 +5135,7 @@ "level_3_lighting_code_definition_id": 77, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4573,6 +5144,7 @@ "level_3_lighting_code_definition_id": 80, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4581,6 +5153,7 @@ "level_3_lighting_code_definition_id": 81, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4589,6 +5162,7 @@ "level_3_lighting_code_definition_id": 83, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 414, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4597,6 +5171,7 @@ "level_3_lighting_code_definition_id": 97, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4605,6 +5180,7 @@ "level_3_lighting_code_definition_id": 98, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 431, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4613,6 +5189,7 @@ "level_3_lighting_code_definition_id": 114, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4621,6 +5198,7 @@ "level_3_lighting_code_definition_id": 115, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4629,6 +5207,7 @@ "level_3_lighting_code_definition_id": 116, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4637,6 +5216,7 @@ "level_3_lighting_code_definition_id": 117, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4645,6 +5225,7 @@ "level_3_lighting_code_definition_id": 119, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4653,6 +5234,7 @@ "level_3_lighting_code_definition_id": 120, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4661,6 +5243,7 @@ "level_3_lighting_code_definition_id": 122, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4669,6 +5252,7 @@ "level_3_lighting_code_definition_id": 124, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4677,6 +5261,7 @@ "level_3_lighting_code_definition_id": 125, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4685,6 +5270,7 @@ "level_3_lighting_code_definition_id": 126, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4693,6 +5279,7 @@ "level_3_lighting_code_definition_id": 128, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 403, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4701,6 +5288,7 @@ "level_3_lighting_code_definition_id": 139, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4709,6 +5297,7 @@ "level_3_lighting_code_definition_id": 140, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4717,6 +5306,7 @@ "level_3_lighting_code_definition_id": 141, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4725,6 +5315,7 @@ "level_3_lighting_code_definition_id": 134, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4733,6 +5324,7 @@ "level_3_lighting_code_definition_id": 33, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4741,6 +5333,7 @@ "level_3_lighting_code_definition_id": 139, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 0, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4749,6 +5342,7 @@ "level_3_lighting_code_definition_id": 36, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4757,6 +5351,7 @@ "level_3_lighting_code_definition_id": 135, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4765,6 +5360,7 @@ "level_3_lighting_code_definition_id": 44, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4773,6 +5369,7 @@ "level_3_lighting_code_definition_id": 46, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 471, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4781,6 +5378,7 @@ "level_3_lighting_code_definition_id": 48, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 710, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4789,6 +5387,7 @@ "level_3_lighting_code_definition_id": 49, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4797,6 +5396,7 @@ "level_3_lighting_code_definition_id": 50, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4805,6 +5405,7 @@ "level_3_lighting_code_definition_id": 51, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4813,6 +5414,7 @@ "level_3_lighting_code_definition_id": 52, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4821,6 +5423,7 @@ "level_3_lighting_code_definition_id": 55, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4829,6 +5432,7 @@ "level_3_lighting_code_definition_id": 62, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4837,6 +5441,7 @@ "level_3_lighting_code_definition_id": 62, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4845,6 +5450,7 @@ "level_3_lighting_code_definition_id": 56, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 308, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4853,6 +5459,7 @@ "level_3_lighting_code_definition_id": 124, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4861,6 +5468,7 @@ "level_3_lighting_code_definition_id": 62, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4869,6 +5477,7 @@ "level_3_lighting_code_definition_id": 102, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 888, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4877,6 +5486,7 @@ "level_3_lighting_code_definition_id": 63, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4885,6 +5495,7 @@ "level_3_lighting_code_definition_id": 102, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4893,6 +5504,7 @@ "level_3_lighting_code_definition_id": 100, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4901,6 +5513,7 @@ "level_3_lighting_code_definition_id": 118, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 431, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4909,6 +5522,7 @@ "level_3_lighting_code_definition_id": 65, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4917,6 +5531,7 @@ "level_3_lighting_code_definition_id": 103, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4925,6 +5540,7 @@ "level_3_lighting_code_definition_id": 82, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 54, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4933,6 +5549,7 @@ "level_3_lighting_code_definition_id": 55, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4941,6 +5558,7 @@ "level_3_lighting_code_definition_id": 64, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 538, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4949,6 +5567,7 @@ "level_3_lighting_code_definition_id": 66, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4957,6 +5576,7 @@ "level_3_lighting_code_definition_id": 68, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4965,6 +5585,7 @@ "level_3_lighting_code_definition_id": 14, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4973,6 +5594,7 @@ "level_3_lighting_code_definition_id": 96, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4981,6 +5603,7 @@ "level_3_lighting_code_definition_id": 69, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4989,6 +5612,7 @@ "level_3_lighting_code_definition_id": 70, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -4997,6 +5621,7 @@ "level_3_lighting_code_definition_id": 76, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5005,6 +5630,7 @@ "level_3_lighting_code_definition_id": 45, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5013,6 +5639,7 @@ "level_3_lighting_code_definition_id": 15, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5021,6 +5648,7 @@ "level_3_lighting_code_definition_id": 104, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5029,6 +5657,7 @@ "level_3_lighting_code_definition_id": 17, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5037,6 +5666,7 @@ "level_3_lighting_code_definition_id": 105, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5045,6 +5675,7 @@ "level_3_lighting_code_definition_id": 106, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5053,6 +5684,7 @@ "level_3_lighting_code_definition_id": 19, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 414, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5061,6 +5693,7 @@ "level_3_lighting_code_definition_id": 79, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5069,6 +5702,7 @@ "level_3_lighting_code_definition_id": 107, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 1184, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5077,6 +5711,7 @@ "level_3_lighting_code_definition_id": 108, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5085,6 +5720,7 @@ "level_3_lighting_code_definition_id": 104, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 888, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5093,6 +5729,7 @@ "level_3_lighting_code_definition_id": 109, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5101,6 +5738,7 @@ "level_3_lighting_code_definition_id": 101, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5109,6 +5747,7 @@ "level_3_lighting_code_definition_id": 24, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5117,6 +5756,7 @@ "level_3_lighting_code_definition_id": 110, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5125,6 +5765,7 @@ "level_3_lighting_code_definition_id": 77, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 323, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5133,6 +5774,7 @@ "level_3_lighting_code_definition_id": 84, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5141,6 +5783,7 @@ "level_3_lighting_code_definition_id": 86, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5149,6 +5792,7 @@ "level_3_lighting_code_definition_id": 99, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 59, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5157,6 +5801,7 @@ "level_3_lighting_code_definition_id": 28, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 1184, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5165,6 +5810,7 @@ "level_3_lighting_code_definition_id": 89, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5173,6 +5819,7 @@ "level_3_lighting_code_definition_id": 91, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5181,6 +5828,7 @@ "level_3_lighting_code_definition_id": 30, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5189,6 +5837,7 @@ "level_3_lighting_code_definition_id": 92, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5197,6 +5846,7 @@ "level_3_lighting_code_definition_id": 32, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5205,6 +5855,7 @@ "level_3_lighting_code_definition_id": 25, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5213,6 +5864,7 @@ "level_3_lighting_code_definition_id": 1, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5221,6 +5873,7 @@ "level_3_lighting_code_definition_id": 2, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5229,6 +5882,7 @@ "level_3_lighting_code_definition_id": 3, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5237,6 +5891,7 @@ "level_3_lighting_code_definition_id": 4, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5245,6 +5900,7 @@ "level_3_lighting_code_definition_id": 5, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5253,6 +5909,7 @@ "level_3_lighting_code_definition_id": 6, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5261,6 +5918,7 @@ "level_3_lighting_code_definition_id": 7, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5269,6 +5927,7 @@ "level_3_lighting_code_definition_id": 8, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5277,6 +5936,7 @@ "level_3_lighting_code_definition_id": 9, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5285,6 +5945,7 @@ "level_3_lighting_code_definition_id": 10, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5293,6 +5954,7 @@ "level_3_lighting_code_definition_id": 11, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5301,6 +5963,7 @@ "level_3_lighting_code_definition_id": 12, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5309,6 +5972,7 @@ "level_3_lighting_code_definition_id": 13, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5317,6 +5981,7 @@ "level_3_lighting_code_definition_id": 16, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5325,6 +5990,7 @@ "level_3_lighting_code_definition_id": 18, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5333,6 +5999,7 @@ "level_3_lighting_code_definition_id": 20, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 54, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5341,6 +6008,7 @@ "level_3_lighting_code_definition_id": 21, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5349,6 +6017,7 @@ "level_3_lighting_code_definition_id": 22, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 426, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5357,6 +6026,7 @@ "level_3_lighting_code_definition_id": 23, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5365,6 +6035,7 @@ "level_3_lighting_code_definition_id": 27, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 471, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5373,6 +6044,7 @@ "level_3_lighting_code_definition_id": 29, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5381,6 +6053,7 @@ "level_3_lighting_code_definition_id": 26, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5389,6 +6062,7 @@ "level_3_lighting_code_definition_id": 31, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5397,6 +6071,7 @@ "level_3_lighting_code_definition_id": 38, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5405,6 +6080,7 @@ "level_3_lighting_code_definition_id": 39, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5413,6 +6089,7 @@ "level_3_lighting_code_definition_id": 40, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5421,6 +6098,7 @@ "level_3_lighting_code_definition_id": 41, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 426, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5429,6 +6107,7 @@ "level_3_lighting_code_definition_id": 42, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5437,6 +6116,7 @@ "level_3_lighting_code_definition_id": 43, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5445,6 +6125,7 @@ "level_3_lighting_code_definition_id": 47, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 471, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5453,6 +6134,7 @@ "level_3_lighting_code_definition_id": 54, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5461,6 +6143,7 @@ "level_3_lighting_code_definition_id": 61, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5469,6 +6152,7 @@ "level_3_lighting_code_definition_id": 57, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5477,6 +6161,7 @@ "level_3_lighting_code_definition_id": 58, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5485,6 +6170,7 @@ "level_3_lighting_code_definition_id": 60, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5493,6 +6179,7 @@ "level_3_lighting_code_definition_id": 73, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 178, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5501,6 +6188,7 @@ "level_3_lighting_code_definition_id": 74, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 118, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5509,6 +6197,7 @@ "level_3_lighting_code_definition_id": 75, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5517,6 +6206,7 @@ "level_3_lighting_code_definition_id": 78, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5525,6 +6215,7 @@ "level_3_lighting_code_definition_id": 80, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5533,6 +6224,7 @@ "level_3_lighting_code_definition_id": 81, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 414, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5541,6 +6233,7 @@ "level_3_lighting_code_definition_id": 94, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5549,6 +6242,7 @@ "level_3_lighting_code_definition_id": 95, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 431, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5557,6 +6251,7 @@ "level_3_lighting_code_definition_id": 111, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5565,6 +6260,7 @@ "level_3_lighting_code_definition_id": 112, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5573,6 +6269,7 @@ "level_3_lighting_code_definition_id": 113, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5581,6 +6278,7 @@ "level_3_lighting_code_definition_id": 114, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5589,6 +6287,7 @@ "level_3_lighting_code_definition_id": 116, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5597,6 +6296,7 @@ "level_3_lighting_code_definition_id": 117, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5605,6 +6305,7 @@ "level_3_lighting_code_definition_id": 119, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 592, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5613,6 +6314,7 @@ "level_3_lighting_code_definition_id": 121, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 474, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5621,6 +6323,7 @@ "level_3_lighting_code_definition_id": 122, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5629,6 +6332,7 @@ "level_3_lighting_code_definition_id": 123, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5637,6 +6341,7 @@ "level_3_lighting_code_definition_id": 125, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 403, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5645,6 +6350,7 @@ "level_3_lighting_code_definition_id": 136, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 296, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5653,6 +6359,7 @@ "level_3_lighting_code_definition_id": 137, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 355, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" }, { @@ -5661,6 +6368,7 @@ "level_3_lighting_code_definition_id": 138, "lighting_technology_name": "default", "lighting_space_type_target_illuminance_setpoint": 237, + "lighting_space_type_target_illuminance_setpoint_unit": "Lux", "annotation": "illuminance setpoint values have been determined based on \"2019\" on total horizontal illuminance values provided by IES" } ] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py b/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py index 457b922cb4..7466002774 100644 --- a/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py +++ b/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py @@ -10,6 +10,7 @@ level_3_lighting_code_definition_id: id from level_3_lighting_definition index lighting_technology_name: TEXT lighting_space_type_target_illuminance_setpoint: NUMERIC +lighting_space_type_target_illuminance_setpoint_unit: TEXT """ CREATE_LIGHT_SUBSPACE_TABLE = f""" @@ -20,6 +21,7 @@ level_3_lighting_code_definition_id INTEGER NOT NULL, lighting_technology_name TEXT, lighting_space_type_target_illuminance_setpoint NUMERIC, +lighting_space_type_target_illuminance_setpoint_unit TEXT, annotation TEXT, FOREIGN KEY(lighting_space_type_name) REFERENCES support_lighting_space_type_name_tags(lighting_space_type_name) FOREIGN KEY(lighting_technology_name) REFERENCES support_lighting_technologies(lighting_technology_definition_name) @@ -34,9 +36,10 @@ level_3_lighting_code_definition_id, lighting_technology_name, lighting_space_type_target_illuminance_setpoint, + lighting_space_type_target_illuminance_setpoint_unit, annotation ) - VALUES (?, ?, ?, ?, ?, ?); + VALUES (?, ?, ?, ?, ?, ?, ?); """ RECORD_TEMPLATE = { @@ -45,6 +48,7 @@ "level_3_lighting_code_definition_id": "", "lighting_technology_name": "", "lighting_space_type_target_illuminance_setpoint": 0.0, + "lighting_space_type_target_illuminance_setpoint_unit": "lux", "annotation": "", } @@ -84,6 +88,7 @@ def _preprocess_record(self, record): getattr_either("level_3_lighting_code_definition_id", record), getattr_either("lighting_technology_name", record), getattr_either("lighting_space_type_target_illuminance_setpoint", record), + getattr_either("lighting_space_type_target_illuminance_setpoint_unit", record, "lux"), getattr_either("annotation", record), ) From 9a9c1ac4d4273d47f0b8a4e06f82d1f98943754b Mon Sep 17 00:00:00 2001 From: Weili Xu Date: Wed, 31 May 2023 07:57:32 -0700 Subject: [PATCH 31/45] reformat file --- .../database_tables/level_2_lighting_space_types.py | 4 +++- 1 file changed, 3 insertions(+), 1 deletion(-) diff --git a/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py b/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py index 7466002774..b725d79bbf 100644 --- a/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py +++ b/data/openstudio_standards_data/database_tables/level_2_lighting_space_types.py @@ -88,7 +88,9 @@ def _preprocess_record(self, record): getattr_either("level_3_lighting_code_definition_id", record), getattr_either("lighting_technology_name", record), getattr_either("lighting_space_type_target_illuminance_setpoint", record), - getattr_either("lighting_space_type_target_illuminance_setpoint_unit", record, "lux"), + getattr_either( + "lighting_space_type_target_illuminance_setpoint_unit", record, "lux" + ), getattr_either("annotation", record), ) From 960137d3ab68f0813f6d33a30e10d1505080deda Mon Sep 17 00:00:00 2001 From: Weili Xu Date: Thu, 1 Jun 2023 10:06:35 -0700 Subject: [PATCH 32/45] update client code --- data/openstudio_standards_data/client.py | 14 ++++++++++---- 1 file changed, 10 insertions(+), 4 deletions(-) diff --git a/data/openstudio_standards_data/client.py b/data/openstudio_standards_data/client.py index 548d9e1650..cd515c5eef 100644 --- a/data/openstudio_standards_data/client.py +++ b/data/openstudio_standards_data/client.py @@ -1,6 +1,5 @@ -from applications.create_openstudio_standards_json import ( - create_openstudio_standards_building_data_json, -) +import logging + from applications.database_maintenance import ( export_openstudio_standards_database_to_json, export_openstudio_standards_database_to_csv, @@ -14,6 +13,13 @@ from database_engine.database import create_connect from query.fetch.database_table import fetch_a_record_from_table_by_id +logging.basicConfig( + filename="new_log", + filemode="a", + format="%(asctime)s,%(msecs)d %(name)s %(levelname)s %(message)s", + datefmt="%H:%M:%S", + level=logging.DEBUG, +) conn = create_connect(None) # create_openstudio_standards_database_from_csv(conn) # a = fetch_a_record_from_table_by_id(conn, "level_3_lighting_90_1_2019", 1) @@ -52,4 +58,4 @@ } ] -update_openstudio_standards_space_data(conn, update_json) +# update_openstudio_standards_space_data(conn, update_json) From d3c30d735084830cb2bfe5b15d9e9b8befa4518f Mon Sep 17 00:00:00 2001 From: "Lerond, Jeremy" Date: Thu, 24 Aug 2023 15:16:09 -0700 Subject: [PATCH 33/45] Change space types used in the prototype templates to the new space types supported by the database. --- .../ASHRAE90120042007RetailStandalone.osm | 8 +- data/geometry/ASHRAE90120042007Warehouse.osm | 6 +- data/geometry/ASHRAE90120102013Warehouse.osm | 6 +- .../ASHRAE9012010RetailStandalone.osm | 8 +- data/geometry/ASHRAE9012010SuperMarket.osm | 24 ++--- data/geometry/ASHRAE9012013Hospital.osm | 42 ++++---- data/geometry/ASHRAE9012013LargeOffice.osm | 12 +-- .../ASHRAE9012013MediumOfficeDetailed.osm | 22 ++--- data/geometry/ASHRAE9012013Outpatient.osm | 64 ++++++------- .../ASHRAE9012013RetailStandalone.osm | 12 +-- data/geometry/ASHRAE9012013SuperMarket.osm | 24 ++--- data/geometry/ASHRAECollege.osm | 30 +++--- data/geometry/ASHRAECourthouse.osm | 44 ++++----- data/geometry/ASHRAEFullServiceRestaurant.osm | 6 +- data/geometry/ASHRAEHighriseApartment.osm | 12 +-- data/geometry/ASHRAEHospital.osm | 38 ++++---- data/geometry/ASHRAELaboratory.osm | 10 +- .../geometry/ASHRAELargeDataCenterHighITE.osm | 2 +- data/geometry/ASHRAELargeDataCenterLowITE.osm | 2 +- data/geometry/ASHRAELargeHotel.osm | 34 +++---- data/geometry/ASHRAELargeOffice.osm | 8 +- data/geometry/ASHRAELargeOfficeDetailed.osm | 28 +++--- data/geometry/ASHRAEMediumOffice.osm | 4 +- data/geometry/ASHRAEMediumOfficeDetailed.osm | 22 ++--- data/geometry/ASHRAEMidriseApartment.osm | 12 +-- data/geometry/ASHRAEOutpatient.osm | 64 ++++++------- data/geometry/ASHRAEPrimarySchool.osm | 22 ++--- .../geometry/ASHRAEQuickServiceRestaurant.osm | 6 +- data/geometry/ASHRAERetailStripmall.osm | 6 +- data/geometry/ASHRAESecondarySchool.osm | 24 ++--- .../geometry/ASHRAESmallDataCenterHighITE.osm | 2 +- data/geometry/ASHRAESmallDataCenterLowITE.osm | 2 +- data/geometry/ASHRAESmallHotel.osm | 44 ++++----- data/geometry/ASHRAESmallOffice.osm | 4 +- data/geometry/ASHRAESmallOfficeDetailed.osm | 20 ++-- data/geometry/ASHRAESuperMarket.osm | 24 ++--- data/geometry/ASHRAESuperTallBuildingbase.osm | 96 +++++++++---------- data/geometry/ASHRAETallBuildingbase.osm | 96 +++++++++---------- data/geometry/CBESMediumOffice.osm | 2 +- data/geometry/CBESRetailStandalone.osm | 8 +- data/geometry/CBESSmallOffice.osm | 4 +- data/geometry/DEER_Asm.osm | 6 +- data/geometry/DEER_ECC.osm | 10 +- data/geometry/DEER_EPr.osm | 10 +- data/geometry/DEER_ERC.osm | 4 +- data/geometry/DEER_ESe.osm | 10 +- data/geometry/DEER_EUn.osm | 12 +-- data/geometry/DEER_Gro.osm | 4 +- data/geometry/DEER_Hsp.osm | 10 +- data/geometry/DEER_Htl.osm | 12 +-- data/geometry/DEER_MBT.osm | 14 +-- data/geometry/DEER_MFm.osm | 2 +- data/geometry/DEER_Mtl.osm | 4 +- data/geometry/DEER_Nrs.osm | 10 +- data/geometry/DEER_OfL.osm | 8 +- data/geometry/DEER_OfS.osm | 6 +- data/geometry/DEER_RFF.osm | 10 +- data/geometry/DEER_RSD.osm | 10 +- data/geometry/DEER_Rt3.osm | 4 +- data/geometry/DEER_RtL.osm | 6 +- data/geometry/DEER_RtS.osm | 4 +- data/geometry/DEER_WRf.osm | 2 +- data/geometry/DOERefLargeHotel.osm | 32 +++---- data/geometry/DOERefLargeOffice.osm | 4 +- data/geometry/DOERefMidriseApartment.osm | 6 +- .../DOERefPre1980FullServiceRestaurant.osm | 4 +- .../DOERefPre1980QuickServiceRestaurant.osm | 4 +- data/geometry/DOERefPre1980SmallOffice.osm | 4 +- data/geometry/DOERefPrimarySchool.osm | 18 ++-- data/geometry/DOERefRetailStandalone.osm | 8 +- data/geometry/DOERefSecondarySchool.osm | 24 ++--- data/geometry/DOERefSmallHotel.osm | 30 +++--- data/geometry/DOERefWarehouse.osm | 6 +- .../database_files/level_1_space_types.json | 24 ++--- 74 files changed, 613 insertions(+), 613 deletions(-) diff --git a/data/geometry/ASHRAE90120042007RetailStandalone.osm b/data/geometry/ASHRAE90120042007RetailStandalone.osm index 8a5aabdfea..1c456c3e23 100644 --- a/data/geometry/ASHRAE90120042007RetailStandalone.osm +++ b/data/geometry/ASHRAE90120042007RetailStandalone.osm @@ -1437,7 +1437,7 @@ OS:SpaceType, {a3a0739e-a571-406d-be23-3a1109c00149}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Retail, !- Standards Building Type - Back_Space; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {a3a0739e-a571-406d-be23-3a1109c00149}, !- Handle @@ -1454,7 +1454,7 @@ OS:SpaceType, {76c09621-8ebd-4f85-9aa1-e7b662cba73a}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Retail, !- Standards Building Type - Entry; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {76c09621-8ebd-4f85-9aa1-e7b662cba73a}, !- Handle @@ -1471,7 +1471,7 @@ OS:SpaceType, {fa5b1461-b656-4d07-a74e-d98fc640db1d}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Retail, !- Standards Building Type - Point_of_Sale; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {fa5b1461-b656-4d07-a74e-d98fc640db1d}, !- Handle @@ -1488,7 +1488,7 @@ OS:SpaceType, {881fc831-ec2a-47eb-9248-d56a79ee8cb0}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Retail, !- Standards Building Type - Retail; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {881fc831-ec2a-47eb-9248-d56a79ee8cb0}, !- Handle diff --git a/data/geometry/ASHRAE90120042007Warehouse.osm b/data/geometry/ASHRAE90120042007Warehouse.osm index dfd42e4d42..44253996e4 100644 --- a/data/geometry/ASHRAE90120042007Warehouse.osm +++ b/data/geometry/ASHRAE90120042007Warehouse.osm @@ -1050,7 +1050,7 @@ OS:SpaceType, {397a9834-ca46-44f2-bf97-1aa5fc23a67d}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Warehouse, !- Standards Building Type - Bulk; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {397a9834-ca46-44f2-bf97-1aa5fc23a67d}, !- Handle @@ -1067,7 +1067,7 @@ OS:SpaceType, {f4306e95-b5d7-4c53-b22d-f8fa8e9ac849}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Warehouse, !- Standards Building Type - Fine; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {f4306e95-b5d7-4c53-b22d-f8fa8e9ac849}, !- Handle @@ -1084,7 +1084,7 @@ OS:SpaceType, {c5bf423d-0ee6-40ac-b721-797e5dbdcfa2}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Warehouse, !- Standards Building Type - Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {c5bf423d-0ee6-40ac-b721-797e5dbdcfa2}, !- Handle diff --git a/data/geometry/ASHRAE90120102013Warehouse.osm b/data/geometry/ASHRAE90120102013Warehouse.osm index 558a39566d..b733cf9d1d 100644 --- a/data/geometry/ASHRAE90120102013Warehouse.osm +++ b/data/geometry/ASHRAE90120102013Warehouse.osm @@ -1662,7 +1662,7 @@ OS:SpaceType, {397a9834-ca46-44f2-bf97-1aa5fc23a67d}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Warehouse, !- Standards Building Type - Bulk; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {397a9834-ca46-44f2-bf97-1aa5fc23a67d}, !- Handle @@ -1679,7 +1679,7 @@ OS:SpaceType, {f4306e95-b5d7-4c53-b22d-f8fa8e9ac849}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Warehouse, !- Standards Building Type - Fine; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {f4306e95-b5d7-4c53-b22d-f8fa8e9ac849}, !- Handle @@ -1696,7 +1696,7 @@ OS:SpaceType, {c5bf423d-0ee6-40ac-b721-797e5dbdcfa2}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Warehouse, !- Standards Building Type - Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {c5bf423d-0ee6-40ac-b721-797e5dbdcfa2}, !- Handle diff --git a/data/geometry/ASHRAE9012010RetailStandalone.osm b/data/geometry/ASHRAE9012010RetailStandalone.osm index a574256561..993541ab89 100644 --- a/data/geometry/ASHRAE9012010RetailStandalone.osm +++ b/data/geometry/ASHRAE9012010RetailStandalone.osm @@ -1574,7 +1574,7 @@ OS:SpaceType, {167cc7b7-8eac-4e49-b28e-caa335790466}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Retail, !- Standards Building Type - Back_Space; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {167cc7b7-8eac-4e49-b28e-caa335790466}, !- Handle @@ -1591,7 +1591,7 @@ OS:SpaceType, {0f7e4bc8-2048-478f-affd-4076526a56ae}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Retail, !- Standards Building Type - Entry; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {0f7e4bc8-2048-478f-affd-4076526a56ae}, !- Handle @@ -1608,7 +1608,7 @@ OS:SpaceType, {d71c19c2-0ea4-4baf-a26a-d5fd227fcca6}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Retail, !- Standards Building Type - Point_of_Sale; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {d71c19c2-0ea4-4baf-a26a-d5fd227fcca6}, !- Handle @@ -1625,7 +1625,7 @@ OS:SpaceType, {72a5f3a5-1e45-49c4-b0dc-cf0379012f35}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Retail, !- Standards Building Type - Retail; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {72a5f3a5-1e45-49c4-b0dc-cf0379012f35}, !- Handle diff --git a/data/geometry/ASHRAE9012010SuperMarket.osm b/data/geometry/ASHRAE9012010SuperMarket.osm index d007f0b49b..4d57b3493e 100644 --- a/data/geometry/ASHRAE9012010SuperMarket.osm +++ b/data/geometry/ASHRAE9012010SuperMarket.osm @@ -2435,7 +2435,7 @@ OS:SpaceType, {d5a4d3a8-a5fd-4aaf-806d-a06898d735bb}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Sales; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {584d5941-6807-4c85-a8e1-f325c9415f01}, !- Handle @@ -2452,7 +2452,7 @@ OS:SpaceType, {0fd86b86-8514-428b-983a-e05274d038f3}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Produce; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {fd47fad6-64f7-4aef-9625-215792b21da0}, !- Handle @@ -2469,7 +2469,7 @@ OS:SpaceType, {85790e85-be38-4905-859f-466ed899db55}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Deli; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {e61d1fd0-7c51-4d2d-a700-6916a13f4e39}, !- Handle @@ -2486,7 +2486,7 @@ OS:SpaceType, {cf17cb7d-482f-438f-a0c4-1a5f373a25d8}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Bakery; !- Standards Space Type + food preparation; !- Standards Space Type OS:Rendering:Color, {5865b2f2-0f2b-4625-a902-27f01e50d17d}, !- Handle @@ -2503,7 +2503,7 @@ OS:SpaceType, {191d53fa-876c-4ae5-b385-65c995be31d6}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {c683d2c8-6126-4dfd-bd42-c3e2177c19f0}, !- Handle @@ -2520,7 +2520,7 @@ OS:SpaceType, {aabefe66-d579-4405-bf24-3f5576b42761}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Meeting; !- Standards Space Type + conference/meeting/multipurpose; !- Standards Space Type OS:Rendering:Color, {15f77b5e-c5c3-4b09-aad3-2d4e57dc3e7c}, !- Handle @@ -2537,7 +2537,7 @@ OS:SpaceType, {3591a590-5c05-47aa-86a7-b9239bec0c25}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Dining; !- Standards Space Type + dining; !- Standards Space Type OS:Rendering:Color, {e20219b6-54ee-40e5-a565-e509c437629a}, !- Handle @@ -2554,7 +2554,7 @@ OS:SpaceType, {820f5e17-d483-4323-a081-c2609441316e}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Restroom; !- Standards Space Type + restroom; !- Standards Space Type OS:Rendering:Color, {c02273df-695e-41c6-bdb5-86d9c30f802c}, !- Handle @@ -2571,7 +2571,7 @@ OS:SpaceType, {95077061-b895-41e0-a684-f88fbf79e327}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Elec/MechRoom; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {e40b28ee-1d55-46c6-9b59-e70c8ae0d0af}, !- Handle @@ -2588,7 +2588,7 @@ OS:SpaceType, {a748bbb9-c181-4842-a74f-8c4aed370da6}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Corridor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {49694992-18d0-4a74-9162-04a571406547}, !- Handle @@ -2605,7 +2605,7 @@ OS:SpaceType, {823782b0-6a99-4868-b14c-a00a41c45e53}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Vestibule; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {7a66eb1c-2621-4acc-ac8f-8333f93ca888}, !- Handle @@ -2622,7 +2622,7 @@ OS:SpaceType, {8f01cc13-2d9b-4cd7-b3e6-0e73f34ad81c}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - DryStorage; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {8ce4180d-d9e9-4145-9f5e-fbe6401853ad}, !- Handle diff --git a/data/geometry/ASHRAE9012013Hospital.osm b/data/geometry/ASHRAE9012013Hospital.osm index bed44b2232..50a6136566 100644 --- a/data/geometry/ASHRAE9012013Hospital.osm +++ b/data/geometry/ASHRAE9012013Hospital.osm @@ -16428,7 +16428,7 @@ OS:SpaceType, {31d1d9b1-5601-4629-bfe8-f747556765cf}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - Corridor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {31d1d9b1-5601-4629-bfe8-f747556765cf}, !- Handle @@ -16445,7 +16445,7 @@ OS:SpaceType, {804342e9-b917-49ea-94bf-1b2148298cc7}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - Dining; !- Standards Space Type + dining; !- Standards Space Type OS:Rendering:Color, {804342e9-b917-49ea-94bf-1b2148298cc7}, !- Handle @@ -16462,7 +16462,7 @@ OS:SpaceType, {e9d3e608-97e4-4656-9f54-535d087e6ec7}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - ER_Exam; !- Standards Space Type + exam/treatment; !- Standards Space Type OS:Rendering:Color, {e9d3e608-97e4-4656-9f54-535d087e6ec7}, !- Handle @@ -16479,7 +16479,7 @@ OS:SpaceType, {d7c03283-af40-4c1e-946b-b8abb9d98530}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - ER_NurseStn; !- Standards Space Type + nurses station; !- Standards Space Type OS:Rendering:Color, {d7c03283-af40-4c1e-946b-b8abb9d98530}, !- Handle @@ -16496,7 +16496,7 @@ OS:SpaceType, {66701b48-1812-4bf6-9aff-9f8465a66eca}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - ER_Trauma; !- Standards Space Type + emergency room; !- Standards Space Type OS:Rendering:Color, {66701b48-1812-4bf6-9aff-9f8465a66eca}, !- Handle @@ -16513,7 +16513,7 @@ OS:SpaceType, {26e979b3-9849-497b-8590-847b62b8469c}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - ER_Triage; !- Standards Space Type + emergency room; !- Standards Space Type OS:Rendering:Color, {26e979b3-9849-497b-8590-847b62b8469c}, !- Handle @@ -16530,7 +16530,7 @@ OS:SpaceType, {650f8517-fcf2-49ef-8016-83b8d3a28dae}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - ICU_NurseStn; !- Standards Space Type + nurses station; !- Standards Space Type OS:Rendering:Color, {650f8517-fcf2-49ef-8016-83b8d3a28dae}, !- Handle @@ -16547,7 +16547,7 @@ OS:SpaceType, {7806b59a-5e1b-43f7-be19-43edea196cc2}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - ICU_Open; !- Standards Space Type + exam/treatment; !- Standards Space Type OS:Rendering:Color, {7806b59a-5e1b-43f7-be19-43edea196cc2}, !- Handle @@ -16564,7 +16564,7 @@ OS:SpaceType, {e2b83995-a5c3-486a-bab7-0673dfc54ba9}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - ICU_PatRm; !- Standards Space Type + patient room; !- Standards Space Type OS:Rendering:Color, {e2b83995-a5c3-486a-bab7-0673dfc54ba9}, !- Handle @@ -16581,7 +16581,7 @@ OS:SpaceType, {53e8e7a0-f3c2-495e-8b90-6cb411b8ade7}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - Kitchen; !- Standards Space Type + food preparation; !- Standards Space Type OS:Rendering:Color, {53e8e7a0-f3c2-495e-8b90-6cb411b8ade7}, !- Handle @@ -16598,7 +16598,7 @@ OS:SpaceType, {763e19bd-42cc-404c-8fa9-d6ff5f366f08}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - Lab; !- Standards Space Type + laboratory; !- Standards Space Type OS:Rendering:Color, {763e19bd-42cc-404c-8fa9-d6ff5f366f08}, !- Handle @@ -16615,7 +16615,7 @@ OS:SpaceType, {1a81df68-0664-46fe-b4c9-03609dd62264}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - Lobby; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {1a81df68-0664-46fe-b4c9-03609dd62264}, !- Handle @@ -16632,7 +16632,7 @@ OS:SpaceType, {31c59b2c-f949-4271-9d2d-0ca10ffba32b}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - NurseStn; !- Standards Space Type + nurses station; !- Standards Space Type OS:Rendering:Color, {31c59b2c-f949-4271-9d2d-0ca10ffba32b}, !- Handle @@ -16649,7 +16649,7 @@ OS:SpaceType, {0ced1fa8-528b-4e7b-92f9-5ee695982263}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - OR; !- Standards Space Type + operating room; !- Standards Space Type OS:Rendering:Color, {0ced1fa8-528b-4e7b-92f9-5ee695982263}, !- Handle @@ -16666,7 +16666,7 @@ OS:SpaceType, {40ec78b9-51ea-4a37-8e9d-34879dd937bf}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {40ec78b9-51ea-4a37-8e9d-34879dd937bf}, !- Handle @@ -16683,7 +16683,7 @@ OS:SpaceType, {44042211-c0b1-4767-89ac-fe36560b04f2}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - Basement; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {44042211-c0b1-4767-89ac-fe36560b04f2}, !- Handle @@ -16700,7 +16700,7 @@ OS:SpaceType, {1eaf223d-e20b-4b2b-afec-bc55e680ab00}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - PatRoom; !- Standards Space Type + patient room; !- Standards Space Type OS:Rendering:Color, {1eaf223d-e20b-4b2b-afec-bc55e680ab00}, !- Handle @@ -16717,7 +16717,7 @@ OS:SpaceType, {02439061-7445-4ccc-9175-791ee3a989c5}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - PhysTherapy; !- Standards Space Type + physical therapy; !- Standards Space Type OS:Rendering:Color, {02439061-7445-4ccc-9175-791ee3a989c5}, !- Handle @@ -16734,7 +16734,7 @@ OS:SpaceType, {49626c0c-6d69-49a2-9500-5f6eea2953a1}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - Radiology; !- Standards Space Type + imaging; !- Standards Space Type OS:Rendering:Color, {49626c0c-6d69-49a2-9500-5f6eea2953a1}, !- Handle @@ -16751,7 +16751,7 @@ OS:SpaceType, {8b254af2-01f3-4936-b806-2f9b2c2d6b3c}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - HospitalOfficeFlr1; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {8b254af2-01f3-4936-b806-2f9b2c2d6b3c}, !- Handle @@ -16768,7 +16768,7 @@ OS:SpaceType, {336e5569-9e3e-49c7-9a9b-1d1a45169673}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - HospitalOfficeFlr5; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {336e5569-9e3e-49c7-9a9b-1d1a45169673}, !- Handle diff --git a/data/geometry/ASHRAE9012013LargeOffice.osm b/data/geometry/ASHRAE9012013LargeOffice.osm index 3de751430e..41793cd023 100644 --- a/data/geometry/ASHRAE9012013LargeOffice.osm +++ b/data/geometry/ASHRAE9012013LargeOffice.osm @@ -5635,7 +5635,7 @@ OS:SpaceType, {deec795f-0d5a-406a-9bf7-2a38ae96582c}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Office, !- Standards Building Type - WholeBuilding - Lg Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {deec795f-0d5a-406a-9bf7-2a38ae96582c}, !- Handle @@ -5652,7 +5652,7 @@ OS:SpaceType, {1662bc3b-58b7-4cf1-b5dd-0ccf3b1c396e}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Office, !- Standards Building Type - OfficeLarge Data Center; !- Standards Space Type + datacenter/low ite; !- Standards Space Type OS:Rendering:Color, {1662bc3b-58b7-4cf1-b5dd-0ccf3b1c396e}, !- Handle @@ -5669,7 +5669,7 @@ OS:SpaceType, {dfeef457-6cd1-40dc-aa16-7b1cfcb585e1}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Office, !- Standards Building Type - OfficeLarge Main Data Center; !- Standards Space Type + datacenter/high ite; !- Standards Space Type OS:Rendering:Color, {dfeef457-6cd1-40dc-aa16-7b1cfcb585e1}, !- Handle @@ -5686,7 +5686,7 @@ OS:SpaceType, {387f9c00-f772-4224-8c40-35c5c7b8a609}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Office, !- Standards Building Type - WholeBuilding - Lg Office-basement; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {387f9c00-f772-4224-8c40-35c5c7b8a609}, !- Handle @@ -5703,7 +5703,7 @@ OS:SpaceType, {43c42105-e066-449e-a862-707906c42529}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Office, !- Standards Building Type - WholeBuilding - Lg Office-others; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {43c42105-e066-449e-a862-707906c42529}, !- Handle @@ -5720,7 +5720,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name , !- Standards Building Type - Plenum; !- Standards Space Type + plenum; !- Standards Space Type OS:SubSurface, {a165c732-31bf-48a6-a413-d61dc5ff3d07}, !- Handle diff --git a/data/geometry/ASHRAE9012013MediumOfficeDetailed.osm b/data/geometry/ASHRAE9012013MediumOfficeDetailed.osm index 74baa3703f..c0409a4a75 100644 --- a/data/geometry/ASHRAE9012013MediumOfficeDetailed.osm +++ b/data/geometry/ASHRAE9012013MediumOfficeDetailed.osm @@ -12912,7 +12912,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - MediumOffice - OpenOffice; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {eb522dc0-a29a-484b-bcb5-8ff1eef34cb0}, !- Handle @@ -12930,7 +12930,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - MediumOffice - ClosedOffice; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {95b38b88-279a-4835-9d48-89da8042a72e}, !- Handle @@ -12948,7 +12948,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - MediumOffice - Classroom; !- Standards Space Type + classroom/lecture/training; !- Standards Space Type OS:Rendering:Color, {687dbd99-171a-4640-8f08-41d2fb660847}, !- Handle @@ -12966,7 +12966,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - MediumOffice - Conference; !- Standards Space Type + conference/meeting/multipurpose; !- Standards Space Type OS:Rendering:Color, {af24da99-6231-473d-a4ee-98e18dec0b26}, !- Handle @@ -12984,7 +12984,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - MediumOffice - Storage; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {b88bdaea-5220-4f5f-8918-1277d0cb2bef}, !- Handle @@ -13002,7 +13002,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - MediumOffice - Corridor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {b365ceb4-b39a-4c6e-be79-d8570755bc74}, !- Handle @@ -13020,7 +13020,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - MediumOffice - Dining; !- Standards Space Type + dining; !- Standards Space Type OS:Rendering:Color, {b3caefa0-edb1-4409-bb19-0da21d57131f}, !- Handle @@ -13038,7 +13038,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - MediumOffice - Lobby; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {a733da76-dbef-4059-a66c-7a259eba3233}, !- Handle @@ -13056,7 +13056,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - MediumOffice - Elec/MechRoom; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {22c28617-85f5-4120-8ce3-46c49fba1406}, !- Handle @@ -13074,7 +13074,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - MediumOffice - Stair; !- Standards Space Type + stairwell; !- Standards Space Type OS:Rendering:Color, {7c21f5c0-74ce-48f5-ac78-18545b8bd117}, !- Handle @@ -13092,7 +13092,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - MediumOffice - Restroom; !- Standards Space Type + restroom; !- Standards Space Type OS:Rendering:Color, {0aa78b18-9198-4ff7-ba83-ca611bc87c18}, !- Handle diff --git a/data/geometry/ASHRAE9012013Outpatient.osm b/data/geometry/ASHRAE9012013Outpatient.osm index 29696ee830..ac8e868d49 100644 --- a/data/geometry/ASHRAE9012013Outpatient.osm +++ b/data/geometry/ASHRAE9012013Outpatient.osm @@ -32849,7 +32849,7 @@ OS:SpaceType, {54db1ed1-80e8-486f-899f-035e0e97239f}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Anesthesia; !- Standards Space Type + exam/treatment; !- Standards Space Type OS:Rendering:Color, {54db1ed1-80e8-486f-899f-035e0e97239f}, !- Handle @@ -32866,7 +32866,7 @@ OS:SpaceType, {df814a82-3e83-4733-b2cb-dcb620901a69}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - BioHazard; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {df814a82-3e83-4733-b2cb-dcb620901a69}, !- Handle @@ -32883,7 +32883,7 @@ OS:SpaceType, {81ab0734-072e-4c44-8dc3-3e9acde5d403}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Cafe; !- Standards Space Type + dining; !- Standards Space Type OS:Rendering:Color, {81ab0734-072e-4c44-8dc3-3e9acde5d403}, !- Handle @@ -32900,7 +32900,7 @@ OS:SpaceType, {5192d441-bb7c-41bf-b24a-ddcdeab8b747}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - CleanWork; !- Standards Space Type + exam/treatment; !- Standards Space Type OS:Rendering:Color, {5192d441-bb7c-41bf-b24a-ddcdeab8b747}, !- Handle @@ -32917,7 +32917,7 @@ OS:SpaceType, {7602e6ab-d574-4523-819b-9dbc607dd42d}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Conference; !- Standards Space Type + conference/meeting/multipurpose; !- Standards Space Type OS:Rendering:Color, {7602e6ab-d574-4523-819b-9dbc607dd42d}, !- Handle @@ -32934,7 +32934,7 @@ OS:SpaceType, {7914d0d4-bf0c-4db6-a57d-430cdc4f66e5}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - DressingRoom; !- Standards Space Type + dressing room; !- Standards Space Type OS:Rendering:Color, {7914d0d4-bf0c-4db6-a57d-430cdc4f66e5}, !- Handle @@ -32951,7 +32951,7 @@ OS:SpaceType, {cc039449-da7a-4737-abda-1ed339cc2113}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Elec/MechRoom; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {cc039449-da7a-4737-abda-1ed339cc2113}, !- Handle @@ -32968,7 +32968,7 @@ OS:SpaceType, {3f5f4d2b-499b-44c9-9d63-c3e20024f78a}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - ElevatorPumpRoom; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {3f5f4d2b-499b-44c9-9d63-c3e20024f78a}, !- Handle @@ -32985,7 +32985,7 @@ OS:SpaceType, {289ef889-859b-4541-9e5c-5c8c30d7385b}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Exam; !- Standards Space Type + exam/treatment; !- Standards Space Type OS:Rendering:Color, {289ef889-859b-4541-9e5c-5c8c30d7385b}, !- Handle @@ -33002,7 +33002,7 @@ OS:SpaceType, {ba4eb9cb-3586-4e65-8541-aa3bc11a1870}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Hall; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {ba4eb9cb-3586-4e65-8541-aa3bc11a1870}, !- Handle @@ -33019,7 +33019,7 @@ OS:SpaceType, {f91b1f68-0eb5-4dc0-bed8-27c4961be65c}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Hall_infil; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {f91b1f68-0eb5-4dc0-bed8-27c4961be65c}, !- Handle @@ -33036,7 +33036,7 @@ OS:SpaceType, {a51b5b7a-405b-44dd-bfab-772935555963}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - IT_Room; !- Standards Space Type + datacenter/low ite; !- Standards Space Type OS:Rendering:Color, {a51b5b7a-405b-44dd-bfab-772935555963}, !- Handle @@ -33053,7 +33053,7 @@ OS:SpaceType, {c27e1678-d235-4fee-8262-bb1ce2382bce}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Janitor; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {c27e1678-d235-4fee-8262-bb1ce2382bce}, !- Handle @@ -33070,7 +33070,7 @@ OS:SpaceType, {bb1dfeec-30eb-452a-b65f-b21605006fef}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Lobby; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {bb1dfeec-30eb-452a-b65f-b21605006fef}, !- Handle @@ -33087,7 +33087,7 @@ OS:SpaceType, {26d485d2-cba6-4799-b13e-18c565e3e3cf}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - LockerRoom; !- Standards Space Type + locker room; !- Standards Space Type OS:Rendering:Color, {26d485d2-cba6-4799-b13e-18c565e3e3cf}, !- Handle @@ -33104,7 +33104,7 @@ OS:SpaceType, {b8e825b7-b2c6-405c-80c9-b3397e74a948}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Lounge; !- Standards Space Type + lounge/breakroom; !- Standards Space Type OS:Rendering:Color, {b8e825b7-b2c6-405c-80c9-b3397e74a948}, !- Handle @@ -33121,7 +33121,7 @@ OS:SpaceType, {0395a4ae-877c-4061-af54-9cd5b80d45b8}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - MRI; !- Standards Space Type + imaging; !- Standards Space Type OS:Rendering:Color, {0395a4ae-877c-4061-af54-9cd5b80d45b8}, !- Handle @@ -33138,7 +33138,7 @@ OS:SpaceType, {ace49159-7d8c-4a75-8dc7-e541dfa842c4}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - MRI_Control; !- Standards Space Type + imaging; !- Standards Space Type OS:Rendering:Color, {ace49159-7d8c-4a75-8dc7-e541dfa842c4}, !- Handle @@ -33155,7 +33155,7 @@ OS:SpaceType, {77acad34-fb1e-4cf2-8618-5fc821e8f9b8}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - MedGas; !- Standards Space Type + exam/treatment; !- Standards Space Type OS:Rendering:Color, {77acad34-fb1e-4cf2-8618-5fc821e8f9b8}, !- Handle @@ -33172,7 +33172,7 @@ OS:SpaceType, {35a9786d-f066-4808-be66-249cfd71d65f}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - NurseStation; !- Standards Space Type + nurses station; !- Standards Space Type OS:Rendering:Color, {35a9786d-f066-4808-be66-249cfd71d65f}, !- Handle @@ -33189,7 +33189,7 @@ OS:SpaceType, {4cf0a6c9-ba59-44d7-8119-29d3da151dce}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - OR; !- Standards Space Type + operating room; !- Standards Space Type OS:Rendering:Color, {4cf0a6c9-ba59-44d7-8119-29d3da151dce}, !- Handle @@ -33206,7 +33206,7 @@ OS:SpaceType, {7c8180e8-b8e3-4750-9762-7b69c07b8647}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {7c8180e8-b8e3-4750-9762-7b69c07b8647}, !- Handle @@ -33223,7 +33223,7 @@ OS:SpaceType, {d6c6ee5b-09e3-41f0-8e1d-8165c403885c}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - PACU; !- Standards Space Type + patient room; !- Standards Space Type OS:Rendering:Color, {d6c6ee5b-09e3-41f0-8e1d-8165c403885c}, !- Handle @@ -33240,7 +33240,7 @@ OS:SpaceType, {3202c1e4-552a-47fb-8849-e9ff9f27e91d}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - PhysicalTherapy; !- Standards Space Type + physical therapy; !- Standards Space Type OS:Rendering:Color, {3202c1e4-552a-47fb-8849-e9ff9f27e91d}, !- Handle @@ -33257,7 +33257,7 @@ OS:SpaceType, {a5da6dba-3010-4e50-a08d-c8c1acce154d}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - PreOp; !- Standards Space Type + operating room; !- Standards Space Type OS:Rendering:Color, {a5da6dba-3010-4e50-a08d-c8c1acce154d}, !- Handle @@ -33274,7 +33274,7 @@ OS:SpaceType, {6701b661-88af-4156-b574-546ca60f54f3}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - ProcedureRoom; !- Standards Space Type + operating room; !- Standards Space Type OS:Rendering:Color, {6701b661-88af-4156-b574-546ca60f54f3}, !- Handle @@ -33291,7 +33291,7 @@ OS:SpaceType, {4b78b7ad-f448-49f3-9fd5-d2818cf20fb6}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Soil Work; !- Standards Space Type + exam/treatment; !- Standards Space Type OS:Rendering:Color, {4b78b7ad-f448-49f3-9fd5-d2818cf20fb6}, !- Handle @@ -33308,7 +33308,7 @@ OS:SpaceType, {b4cea8ff-7836-4a99-a993-03779f4aae86}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Stair; !- Standards Space Type + stairwell; !- Standards Space Type OS:Rendering:Color, {b4cea8ff-7836-4a99-a993-03779f4aae86}, !- Handle @@ -33325,7 +33325,7 @@ OS:SpaceType, {da52f6e0-3816-4e10-945c-7718ea541018}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Toilet; !- Standards Space Type + restroom; !- Standards Space Type OS:Rendering:Color, {da52f6e0-3816-4e10-945c-7718ea541018}, !- Handle @@ -33342,7 +33342,7 @@ OS:SpaceType, {e3e7be2a-044d-4f10-9603-da2aa55c6110}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Xray; !- Standards Space Type + imaging; !- Standards Space Type OS:Rendering:Color, {e3e7be2a-044d-4f10-9603-da2aa55c6110}, !- Handle @@ -33359,7 +33359,7 @@ OS:SpaceType, {7c28a49a-f63e-46c6-9dd3-e4c2cbe8d622}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Reception; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {7c28a49a-f63e-46c6-9dd3-e4c2cbe8d622}, !- Handle @@ -33376,7 +33376,7 @@ OS:SpaceType, {158cc556-36f0-4c04-b601-3a3ac73f51ac}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Undeveloped; !- Standards Space Type + shaft; !- Standards Space Type OS:Rendering:Color, {158cc556-36f0-4c04-b601-3a3ac73f51ac}, !- Handle diff --git a/data/geometry/ASHRAE9012013RetailStandalone.osm b/data/geometry/ASHRAE9012013RetailStandalone.osm index 60de3711d9..78af29ee6c 100644 --- a/data/geometry/ASHRAE9012013RetailStandalone.osm +++ b/data/geometry/ASHRAE9012013RetailStandalone.osm @@ -1574,7 +1574,7 @@ OS:SpaceType, {167cc7b7-8eac-4e49-b28e-caa335790466}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Retail, !- Standards Building Type - Back_Space; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {167cc7b7-8eac-4e49-b28e-caa335790466}, !- Handle @@ -1591,7 +1591,7 @@ OS:SpaceType, {0f7e4bc8-2048-478f-affd-4076526a56ae}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Retail, !- Standards Building Type - Entry; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {0f7e4bc8-2048-478f-affd-4076526a56ae}, !- Handle @@ -1608,7 +1608,7 @@ OS:SpaceType, {d71c19c2-0ea4-4baf-a26a-d5fd227fcca6}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Retail, !- Standards Building Type - Point_of_Sale; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {d71c19c2-0ea4-4baf-a26a-d5fd227fcca6}, !- Handle @@ -1625,7 +1625,7 @@ OS:SpaceType, {72a5f3a5-1e45-49c4-b0dc-cf0379012f35}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Retail, !- Standards Building Type - Retail; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {72a5f3a5-1e45-49c4-b0dc-cf0379012f35}, !- Handle @@ -1642,7 +1642,7 @@ OS:SpaceType, {36228824-8698-4846-8500-606b5c6a7311}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Retail, !- Standards Building Type - Core_Retail; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {36228824-8698-4846-8500-606b5c6a7311}, !- Handle @@ -1659,7 +1659,7 @@ OS:SpaceType, {4f94eb74-b3bb-469e-bfb3-7990f3d6946c}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Retail, !- Standards Building Type - Front_Retail; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {4f94eb74-b3bb-469e-bfb3-7990f3d6946c}, !- Handle diff --git a/data/geometry/ASHRAE9012013SuperMarket.osm b/data/geometry/ASHRAE9012013SuperMarket.osm index 4eba478fa0..f9623e737b 100644 --- a/data/geometry/ASHRAE9012013SuperMarket.osm +++ b/data/geometry/ASHRAE9012013SuperMarket.osm @@ -2435,7 +2435,7 @@ OS:SpaceType, {d5a4d3a8-a5fd-4aaf-806d-a06898d735bb}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Sales; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {584d5941-6807-4c85-a8e1-f325c9415f01}, !- Handle @@ -2452,7 +2452,7 @@ OS:SpaceType, {0fd86b86-8514-428b-983a-e05274d038f3}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Produce; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {fd47fad6-64f7-4aef-9625-215792b21da0}, !- Handle @@ -2469,7 +2469,7 @@ OS:SpaceType, {85790e85-be38-4905-859f-466ed899db55}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Deli; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {e61d1fd0-7c51-4d2d-a700-6916a13f4e39}, !- Handle @@ -2486,7 +2486,7 @@ OS:SpaceType, {cf17cb7d-482f-438f-a0c4-1a5f373a25d8}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Bakery; !- Standards Space Type + food preparation; !- Standards Space Type OS:Rendering:Color, {5865b2f2-0f2b-4625-a902-27f01e50d17d}, !- Handle @@ -2503,7 +2503,7 @@ OS:SpaceType, {191d53fa-876c-4ae5-b385-65c995be31d6}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {c683d2c8-6126-4dfd-bd42-c3e2177c19f0}, !- Handle @@ -2520,7 +2520,7 @@ OS:SpaceType, {aabefe66-d579-4405-bf24-3f5576b42761}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Meeting; !- Standards Space Type + conference/meeting/multipurpose; !- Standards Space Type OS:Rendering:Color, {15f77b5e-c5c3-4b09-aad3-2d4e57dc3e7c}, !- Handle @@ -2537,7 +2537,7 @@ OS:SpaceType, {3591a590-5c05-47aa-86a7-b9239bec0c25}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Dining; !- Standards Space Type + dining; !- Standards Space Type OS:Rendering:Color, {e20219b6-54ee-40e5-a565-e509c437629a}, !- Handle @@ -2554,7 +2554,7 @@ OS:SpaceType, {820f5e17-d483-4323-a081-c2609441316e}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Restroom; !- Standards Space Type + restroom; !- Standards Space Type OS:Rendering:Color, {c02273df-695e-41c6-bdb5-86d9c30f802c}, !- Handle @@ -2571,7 +2571,7 @@ OS:SpaceType, {95077061-b895-41e0-a684-f88fbf79e327}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Elec/MechRoom; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {e40b28ee-1d55-46c6-9b59-e70c8ae0d0af}, !- Handle @@ -2588,7 +2588,7 @@ OS:SpaceType, {a748bbb9-c181-4842-a74f-8c4aed370da6}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Corridor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {49694992-18d0-4a74-9162-04a571406547}, !- Handle @@ -2605,7 +2605,7 @@ OS:SpaceType, {823782b0-6a99-4868-b14c-a00a41c45e53}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Vestibule; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {7a66eb1c-2621-4acc-ac8f-8333f93ca888}, !- Handle @@ -2622,7 +2622,7 @@ OS:SpaceType, {8f01cc13-2d9b-4cd7-b3e6-0e73f34ad81c}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - DryStorage; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {8ce4180d-d9e9-4145-9f5e-fbe6401853ad}, !- Handle diff --git a/data/geometry/ASHRAECollege.osm b/data/geometry/ASHRAECollege.osm index 64ddb0cb13..83e6f9d1b8 100644 --- a/data/geometry/ASHRAECollege.osm +++ b/data/geometry/ASHRAECollege.osm @@ -14475,7 +14475,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template College, !- Standards Building Type - College - Classroom; !- Standards Space Type + classroom/lecture/training; !- Standards Space Type OS:Rendering:Color, {d59683ef-a55e-492d-ad1f-524cc6cccb62}, !- Handle @@ -14493,7 +14493,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template College, !- Standards Building Type - College - Media Center; !- Standards Space Type + computer room; !- Standards Space Type OS:Rendering:Color, {f4b1d35f-0a69-404e-9919-2dc91e2cc5b5}, !- Handle @@ -14511,7 +14511,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template College, !- Standards Building Type - College - Lounge; !- Standards Space Type + lounge/breakroom; !- Standards Space Type OS:Rendering:Color, {49796b7b-227c-416b-8d2b-f52a8a21299f}, !- Handle @@ -14529,7 +14529,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template College, !- Standards Building Type - College - Entrance Lobby; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {cc03a111-314c-40e2-89f2-27cbd7f5878a}, !- Handle @@ -14547,7 +14547,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template College, !- Standards Building Type - College - Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {26acb4e8-d146-4584-808e-ab344c900c35}, !- Handle @@ -14565,7 +14565,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template College, !- Standards Building Type - College - Conference; !- Standards Space Type + conference/meeting/multipurpose; !- Standards Space Type OS:Rendering:Color, {2dd1b0a4-442a-40c2-a7ae-ef4655136e77}, !- Handle @@ -14583,7 +14583,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template College, !- Standards Building Type - College - Restroom; !- Standards Space Type + restroom; !- Standards Space Type OS:Rendering:Color, {5ad3a6cc-27d9-495a-ba21-51fcf7b2a5cb}, !- Handle @@ -14601,7 +14601,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template College, !- Standards Building Type - College - Corridor; !- Standards Space Type + corridor; !- Standards Space Type OS:SpaceType, {6e5c5762-d2d0-48e1-b3f0-dc85148ed47b}, !- Handle @@ -14612,7 +14612,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template College, !- Standards Building Type - College - Elevator Shaft; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {eb36a302-13c5-40d5-83b1-f582d55ea6ec}, !- Handle @@ -14630,7 +14630,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template College, !- Standards Building Type - College - Utility; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {1a8bed03-a9f5-4b60-a98a-15f2d0bd0286}, !- Handle @@ -14655,7 +14655,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template College, !- Standards Building Type - College - Storage; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {55dd2b53-9c5d-4a36-bb21-e820ce98d5dd}, !- Handle @@ -14673,7 +14673,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template College, !- Standards Building Type - College - Stairs; !- Standards Space Type + stairwell; !- Standards Space Type OS:Rendering:Color, {f9c8f680-6a37-4e65-b914-85ad743a9af4}, !- Handle @@ -14698,7 +14698,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template College, !- Standards Building Type - College - Laboratory; !- Standards Space Type + laboratory; !- Standards Space Type OS:Rendering:Color, {1936b8fb-e8b6-4076-a39c-d72b5ead0ecb}, !- Handle @@ -19961,7 +19961,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template College, !- Standards Building Type - College - Art Classroom; !- Standards Space Type + classroom/lecture/training; !- Standards Space Type OS:Rendering:Color, {bfb98788-0227-4b23-93e3-e9fb6304e7d1}, !- Handle @@ -20323,7 +20323,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template College, !- Standards Building Type - College - Lecture Hall; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {555e9fcd-367f-4c24-a355-b4c26ca8b615}, !- Handle diff --git a/data/geometry/ASHRAECourthouse.osm b/data/geometry/ASHRAECourthouse.osm index fbb64110ab..af0f8ed176 100644 --- a/data/geometry/ASHRAECourthouse.osm +++ b/data/geometry/ASHRAECourthouse.osm @@ -26000,7 +26000,7 @@ OS:SpaceType, {7d52e697-0bdd-416e-8d5b-601a576e47c6}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Courthouse, !- Standards Building Type - Courthouse - Break Room; !- Standards Space Type + lounge/breakroom; !- Standards Space Type OS:Rendering:Color, {7d52e697-0bdd-416e-8d5b-601a576e47c6}, !- Handle @@ -26017,7 +26017,7 @@ OS:SpaceType, {6eeef126-879e-4f28-b2eb-cb671f65d522}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Courthouse, !- Standards Building Type - Courthouse - Cell; !- Standards Space Type + confinement cells; !- Standards Space Type OS:Rendering:Color, {6eeef126-879e-4f28-b2eb-cb671f65d522}, !- Handle @@ -26034,7 +26034,7 @@ OS:SpaceType, {f4559668-2f3a-42ac-adbc-632f1a9501fc}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Courthouse, !- Standards Building Type - Courthouse - Conference; !- Standards Space Type + conference/meeting/multipurpose; !- Standards Space Type OS:Rendering:Color, {f4559668-2f3a-42ac-adbc-632f1a9501fc}, !- Handle @@ -26051,7 +26051,7 @@ OS:SpaceType, {57e52c47-845d-45cc-a970-db03de6e89d8}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Courthouse, !- Standards Building Type - Courthouse - Corridor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {57e52c47-845d-45cc-a970-db03de6e89d8}, !- Handle @@ -26068,7 +26068,7 @@ OS:SpaceType, {e14c306a-d9b6-454f-b950-481c889d3393}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Courthouse, !- Standards Building Type - Courthouse - Courtroom; !- Standards Space Type + courtroom; !- Standards Space Type OS:Rendering:Color, {e14c306a-d9b6-454f-b950-481c889d3393}, !- Handle @@ -26085,7 +26085,7 @@ OS:SpaceType, {7c5445bf-2701-417f-a75b-fd2c3782f7f8}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Courthouse, !- Standards Building Type - Courthouse - Courtroom Waiting; !- Standards Space Type + lounge/breakroom; !- Standards Space Type OS:Rendering:Color, {7c5445bf-2701-417f-a75b-fd2c3782f7f8}, !- Handle @@ -26102,7 +26102,7 @@ OS:SpaceType, {5cfcde16-f680-4fe7-bf7b-9895e291730c}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Courthouse, !- Standards Building Type - Courthouse - Elevator Lobby; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {5cfcde16-f680-4fe7-bf7b-9895e291730c}, !- Handle @@ -26119,7 +26119,7 @@ OS:SpaceType, {afd56ee2-d95b-48dc-bb6b-7ba0710ae462}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Courthouse, !- Standards Building Type - Courthouse - Elevator Shaft; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {afd56ee2-d95b-48dc-bb6b-7ba0710ae462}, !- Handle @@ -26136,7 +26136,7 @@ OS:SpaceType, {80a4d7ac-475d-4837-9ee9-acc3a974c851}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Courthouse, !- Standards Building Type - Courthouse - Entrance Lobby; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {80a4d7ac-475d-4837-9ee9-acc3a974c851}, !- Handle @@ -26153,7 +26153,7 @@ OS:SpaceType, {7eef3f7e-dad4-4abf-bd7f-21b431318499}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Courthouse, !- Standards Building Type - Courthouse - Judges Chamber; !- Standards Space Type + judges chambers; !- Standards Space Type OS:Rendering:Color, {7eef3f7e-dad4-4abf-bd7f-21b431318499}, !- Handle @@ -26170,7 +26170,7 @@ OS:SpaceType, {c4bcb6bf-c369-408e-8580-8d955e6a9ab8}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Courthouse, !- Standards Building Type - Courthouse - Jury Assembly; !- Standards Space Type + audience seating; !- Standards Space Type OS:Rendering:Color, {c4bcb6bf-c369-408e-8580-8d955e6a9ab8}, !- Handle @@ -26187,7 +26187,7 @@ OS:SpaceType, {12a096b5-c1e9-4e3d-9a1c-c10e0500a9b8}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Courthouse, !- Standards Building Type - Courthouse - Jury Deliberation; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {12a096b5-c1e9-4e3d-9a1c-c10e0500a9b8}, !- Handle @@ -26204,7 +26204,7 @@ OS:SpaceType, {1c134506-2818-4a4d-9269-af6796e5f751}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Courthouse, !- Standards Building Type - Courthouse - Library; !- Standards Space Type + library; !- Standards Space Type OS:Rendering:Color, {1c134506-2818-4a4d-9269-af6796e5f751}, !- Handle @@ -26221,7 +26221,7 @@ OS:SpaceType, {d6161ec4-a9cd-4bb2-b786-e30684eaa0f5}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Courthouse, !- Standards Building Type - Courthouse - Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {d6161ec4-a9cd-4bb2-b786-e30684eaa0f5}, !- Handle @@ -26238,7 +26238,7 @@ OS:SpaceType, {7a30333c-d7af-4f6c-9b76-f5f3e8c457aa}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Courthouse, !- Standards Building Type - Courthouse - Parking; !- Standards Space Type + interior parking; !- Standards Space Type OS:Rendering:Color, {7a30333c-d7af-4f6c-9b76-f5f3e8c457aa}, !- Handle @@ -26255,7 +26255,7 @@ OS:SpaceType, {f437c278-7404-4657-8ac9-474b14811a0f}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Courthouse, !- Standards Building Type - Courthouse - Plenum; !- Standards Space Type + plenum; !- Standards Space Type OS:Rendering:Color, {f437c278-7404-4657-8ac9-474b14811a0f}, !- Handle @@ -26272,7 +26272,7 @@ OS:SpaceType, {0f19eeb9-54a4-4943-bb6c-c48151a580ee}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Courthouse, !- Standards Building Type - Courthouse - Restrooms; !- Standards Space Type + restroom; !- Standards Space Type OS:Rendering:Color, {0f19eeb9-54a4-4943-bb6c-c48151a580ee}, !- Handle @@ -26289,7 +26289,7 @@ OS:SpaceType, {ef3c565b-24d7-4744-bbaa-7cefbc95a972}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Courthouse, !- Standards Building Type - Courthouse - Security Screening; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {ef3c565b-24d7-4744-bbaa-7cefbc95a972}, !- Handle @@ -26306,7 +26306,7 @@ OS:SpaceType, {8f222ef5-047a-47e5-a034-6bb28561268b}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Courthouse, !- Standards Building Type - Courthouse - Service Shaft; !- Standards Space Type + shaft; !- Standards Space Type OS:Rendering:Color, {8f222ef5-047a-47e5-a034-6bb28561268b}, !- Handle @@ -26323,7 +26323,7 @@ OS:SpaceType, {2d0a0756-4a8f-4654-8fef-ef360413c69e}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Courthouse, !- Standards Building Type - Courthouse - Stairs; !- Standards Space Type + stairwell; !- Standards Space Type OS:Rendering:Color, {2d0a0756-4a8f-4654-8fef-ef360413c69e}, !- Handle @@ -26340,7 +26340,7 @@ OS:SpaceType, {9c20768b-8d7e-4f41-9225-fdf1d876e8ae}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Courthouse, !- Standards Building Type - Courthouse - Storage; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {9c20768b-8d7e-4f41-9225-fdf1d876e8ae}, !- Handle @@ -26357,7 +26357,7 @@ OS:SpaceType, {880d3767-85dd-45b4-9110-49d61aa05b1e}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Courthouse, !- Standards Building Type - Courthouse - Utility; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {880d3767-85dd-45b4-9110-49d61aa05b1e}, !- Handle diff --git a/data/geometry/ASHRAEFullServiceRestaurant.osm b/data/geometry/ASHRAEFullServiceRestaurant.osm index e452af0c12..e4403c0a24 100644 --- a/data/geometry/ASHRAEFullServiceRestaurant.osm +++ b/data/geometry/ASHRAEFullServiceRestaurant.osm @@ -777,7 +777,7 @@ OS:SpaceType, {507a5052-c6fa-4e80-96ea-d8413460cc49}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name FullServiceRestaurant, !- Standards Building Type - Dining; !- Standards Space Type + dining; !- Standards Space Type OS:Rendering:Color, {507a5052-c6fa-4e80-96ea-d8413460cc49}, !- Handle @@ -794,7 +794,7 @@ OS:SpaceType, {de34b478-3803-4e06-a6b0-94fb668f99b0}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name FullServiceRestaurant, !- Standards Building Type - Kitchen; !- Standards Space Type + food preparation; !- Standards Space Type OS:Rendering:Color, {de34b478-3803-4e06-a6b0-94fb668f99b0}, !- Handle @@ -811,7 +811,7 @@ OS:SpaceType, {3a0f162a-46fe-45d9-8a9b-011bcdf88e16}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name FullServiceRestaurant, !- Standards Building Type - Attic; !- Standards Space Type + attic; !- Standards Space Type OS:Rendering:Color, {3a0f162a-46fe-45d9-8a9b-011bcdf88e16}, !- Handle diff --git a/data/geometry/ASHRAEHighriseApartment.osm b/data/geometry/ASHRAEHighriseApartment.osm index 5489bd2984..e1ae583874 100644 --- a/data/geometry/ASHRAEHighriseApartment.osm +++ b/data/geometry/ASHRAEHighriseApartment.osm @@ -21438,7 +21438,7 @@ OS:SpaceType, {507a5052-c6fa-4e80-96ea-d8413460cc49}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name HighriseApartment, !- Standards Building Type - Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {507a5052-c6fa-4e80-96ea-d8413460cc49}, !- Handle @@ -21455,7 +21455,7 @@ OS:SpaceType, {de34b478-3803-4e06-a6b0-94fb668f99b0}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name HighriseApartment, !- Standards Building Type - Corridor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {de34b478-3803-4e06-a6b0-94fb668f99b0}, !- Handle @@ -21472,7 +21472,7 @@ OS:SpaceType, {3a0f162a-46fe-45d9-8a9b-011bcdf88e16}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name HighriseApartment, !- Standards Building Type - Corridor_topfloor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {3a0f162a-46fe-45d9-8a9b-011bcdf88e16}, !- Handle @@ -21489,7 +21489,7 @@ OS:SpaceType, {69c18cae-9d2f-4864-9c57-e3dd9c93faac}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name HighriseApartment, !- Standards Building Type - Apartment; !- Standards Space Type + multifamily; !- Standards Space Type OS:Rendering:Color, {69c18cae-9d2f-4864-9c57-e3dd9c93faac}, !- Handle @@ -21506,7 +21506,7 @@ OS:SpaceType, {13d8edca-f17b-4a9f-8402-de08ca4175c3}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name HighriseApartment, !- Standards Building Type - Apartment_topfloor_WE; !- Standards Space Type + multifamily; !- Standards Space Type OS:Rendering:Color, {13d8edca-f17b-4a9f-8402-de08ca4175c3}, !- Handle @@ -21523,7 +21523,7 @@ OS:SpaceType, {4b81ad58-3059-4888-a5f0-4667974bbc33}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name HighriseApartment, !- Standards Building Type - Apartment_topfloor_NS; !- Standards Space Type + multifamily; !- Standards Space Type OS:Rendering:Color, {4b81ad58-3059-4888-a5f0-4667974bbc33}, !- Handle diff --git a/data/geometry/ASHRAEHospital.osm b/data/geometry/ASHRAEHospital.osm index ae4fffb2cc..4bdbfeb092 100644 --- a/data/geometry/ASHRAEHospital.osm +++ b/data/geometry/ASHRAEHospital.osm @@ -16428,7 +16428,7 @@ OS:SpaceType, {31d1d9b1-5601-4629-bfe8-f747556765cf}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - Corridor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {31d1d9b1-5601-4629-bfe8-f747556765cf}, !- Handle @@ -16445,7 +16445,7 @@ OS:SpaceType, {804342e9-b917-49ea-94bf-1b2148298cc7}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - Dining; !- Standards Space Type + dining; !- Standards Space Type OS:Rendering:Color, {804342e9-b917-49ea-94bf-1b2148298cc7}, !- Handle @@ -16462,7 +16462,7 @@ OS:SpaceType, {e9d3e608-97e4-4656-9f54-535d087e6ec7}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - ER_Exam; !- Standards Space Type + exam/treatment; !- Standards Space Type OS:Rendering:Color, {e9d3e608-97e4-4656-9f54-535d087e6ec7}, !- Handle @@ -16479,7 +16479,7 @@ OS:SpaceType, {d7c03283-af40-4c1e-946b-b8abb9d98530}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - ER_NurseStn; !- Standards Space Type + nurses station; !- Standards Space Type OS:Rendering:Color, {d7c03283-af40-4c1e-946b-b8abb9d98530}, !- Handle @@ -16496,7 +16496,7 @@ OS:SpaceType, {66701b48-1812-4bf6-9aff-9f8465a66eca}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - ER_Trauma; !- Standards Space Type + emergency room; !- Standards Space Type OS:Rendering:Color, {66701b48-1812-4bf6-9aff-9f8465a66eca}, !- Handle @@ -16513,7 +16513,7 @@ OS:SpaceType, {26e979b3-9849-497b-8590-847b62b8469c}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - ER_Triage; !- Standards Space Type + emergency room; !- Standards Space Type OS:Rendering:Color, {26e979b3-9849-497b-8590-847b62b8469c}, !- Handle @@ -16530,7 +16530,7 @@ OS:SpaceType, {650f8517-fcf2-49ef-8016-83b8d3a28dae}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - ICU_NurseStn; !- Standards Space Type + nurses station; !- Standards Space Type OS:Rendering:Color, {650f8517-fcf2-49ef-8016-83b8d3a28dae}, !- Handle @@ -16547,7 +16547,7 @@ OS:SpaceType, {7806b59a-5e1b-43f7-be19-43edea196cc2}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - ICU_Open; !- Standards Space Type + exam/treatment; !- Standards Space Type OS:Rendering:Color, {7806b59a-5e1b-43f7-be19-43edea196cc2}, !- Handle @@ -16564,7 +16564,7 @@ OS:SpaceType, {e2b83995-a5c3-486a-bab7-0673dfc54ba9}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - ICU_PatRm; !- Standards Space Type + patient room; !- Standards Space Type OS:Rendering:Color, {e2b83995-a5c3-486a-bab7-0673dfc54ba9}, !- Handle @@ -16581,7 +16581,7 @@ OS:SpaceType, {53e8e7a0-f3c2-495e-8b90-6cb411b8ade7}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - Kitchen; !- Standards Space Type + food preparation; !- Standards Space Type OS:Rendering:Color, {53e8e7a0-f3c2-495e-8b90-6cb411b8ade7}, !- Handle @@ -16598,7 +16598,7 @@ OS:SpaceType, {763e19bd-42cc-404c-8fa9-d6ff5f366f08}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - Lab; !- Standards Space Type + laboratory; !- Standards Space Type OS:Rendering:Color, {763e19bd-42cc-404c-8fa9-d6ff5f366f08}, !- Handle @@ -16615,7 +16615,7 @@ OS:SpaceType, {1a81df68-0664-46fe-b4c9-03609dd62264}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - Lobby; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {1a81df68-0664-46fe-b4c9-03609dd62264}, !- Handle @@ -16632,7 +16632,7 @@ OS:SpaceType, {31c59b2c-f949-4271-9d2d-0ca10ffba32b}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - NurseStn; !- Standards Space Type + nurses station; !- Standards Space Type OS:Rendering:Color, {31c59b2c-f949-4271-9d2d-0ca10ffba32b}, !- Handle @@ -16649,7 +16649,7 @@ OS:SpaceType, {0ced1fa8-528b-4e7b-92f9-5ee695982263}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - OR; !- Standards Space Type + operating room; !- Standards Space Type OS:Rendering:Color, {0ced1fa8-528b-4e7b-92f9-5ee695982263}, !- Handle @@ -16666,7 +16666,7 @@ OS:SpaceType, {40ec78b9-51ea-4a37-8e9d-34879dd937bf}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {40ec78b9-51ea-4a37-8e9d-34879dd937bf}, !- Handle @@ -16683,7 +16683,7 @@ OS:SpaceType, {44042211-c0b1-4767-89ac-fe36560b04f2}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - Basement; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {44042211-c0b1-4767-89ac-fe36560b04f2}, !- Handle @@ -16700,7 +16700,7 @@ OS:SpaceType, {1eaf223d-e20b-4b2b-afec-bc55e680ab00}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - PatRoom; !- Standards Space Type + patient room; !- Standards Space Type OS:Rendering:Color, {1eaf223d-e20b-4b2b-afec-bc55e680ab00}, !- Handle @@ -16717,7 +16717,7 @@ OS:SpaceType, {02439061-7445-4ccc-9175-791ee3a989c5}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - PhysTherapy; !- Standards Space Type + physical therapy; !- Standards Space Type OS:Rendering:Color, {02439061-7445-4ccc-9175-791ee3a989c5}, !- Handle @@ -16734,7 +16734,7 @@ OS:SpaceType, {49626c0c-6d69-49a2-9500-5f6eea2953a1}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hospital, !- Standards Building Type - Radiology; !- Standards Space Type + imaging; !- Standards Space Type OS:Rendering:Color, {49626c0c-6d69-49a2-9500-5f6eea2953a1}, !- Handle diff --git a/data/geometry/ASHRAELaboratory.osm b/data/geometry/ASHRAELaboratory.osm index 6bb07dd09f..f9cd3ac985 100644 --- a/data/geometry/ASHRAELaboratory.osm +++ b/data/geometry/ASHRAELaboratory.osm @@ -12402,7 +12402,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Laboratory, !- Standards Building Type - Equipment corridor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {7c449471-e44a-44cf-bf7e-8c3376bd55e7}, !- Handle @@ -12420,7 +12420,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Laboratory, !- Standards Building Type - Lab with fume hood; !- Standards Space Type + laboratory; !- Standards Space Type OS:Rendering:Color, {7faddff0-701a-4fb3-af24-6f0a8254bba7}, !- Handle @@ -12438,7 +12438,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Laboratory, !- Standards Building Type - Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {f35e15fc-a426-4389-98c5-8da170be761a}, !- Handle @@ -12456,7 +12456,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Laboratory, !- Standards Building Type - Open lab; !- Standards Space Type + laboratory; !- Standards Space Type OS:Rendering:Color, {ee4078eb-d19b-428c-8273-e6d2eaf64a50}, !- Handle @@ -12726,7 +12726,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Laboratory, !- Standards Building Type - Plenum; !- Standards Space Type + plenum; !- Standards Space Type OS:Rendering:Color, {3cf0e9fa-2854-45ad-822f-49e2653d1463}, !- Handle diff --git a/data/geometry/ASHRAELargeDataCenterHighITE.osm b/data/geometry/ASHRAELargeDataCenterHighITE.osm index a781599ff0..0d0c115861 100644 --- a/data/geometry/ASHRAELargeDataCenterHighITE.osm +++ b/data/geometry/ASHRAELargeDataCenterHighITE.osm @@ -136,7 +136,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeDataCenterHighITE, !- Standards Building Type - StandaloneDataCenter; !- Standards Space Type + datacenter/low ite; !- Standards Space Type OS:ThermalZone, {46a2286d-ca49-4b83-8152-08512e95caf2}, !- Handle diff --git a/data/geometry/ASHRAELargeDataCenterLowITE.osm b/data/geometry/ASHRAELargeDataCenterLowITE.osm index 1e329cedff..c742a2b51f 100644 --- a/data/geometry/ASHRAELargeDataCenterLowITE.osm +++ b/data/geometry/ASHRAELargeDataCenterLowITE.osm @@ -136,7 +136,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeDataCenterLowITE, !- Standards Building Type - StandaloneDataCenter; !- Standards Space Type + datacenter/low ite; !- Standards Space Type OS:ThermalZone, {d16c199c-a9be-4ecd-bd06-61ef3b913647}, !- Handle diff --git a/data/geometry/ASHRAELargeHotel.osm b/data/geometry/ASHRAELargeHotel.osm index 284bad1409..06738a14b1 100644 --- a/data/geometry/ASHRAELargeHotel.osm +++ b/data/geometry/ASHRAELargeHotel.osm @@ -6092,7 +6092,7 @@ OS:SpaceType, {cdb9dbb2-d965-4b7f-aaf5-fc5498d69895}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - Banquet; !- Standards Space Type + dining; !- Standards Space Type OS:Rendering:Color, {cdb9dbb2-d965-4b7f-aaf5-fc5498d69895}, !- Handle @@ -6109,7 +6109,7 @@ OS:SpaceType, {a128b76e-a720-4d8c-a9c7-e945dcb28da0}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - Basement; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {a128b76e-a720-4d8c-a9c7-e945dcb28da0}, !- Handle @@ -6126,7 +6126,7 @@ OS:SpaceType, {4cbf1a19-a1d6-47b1-be2c-e0cb3239b580}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - Cafe; !- Standards Space Type + dining; !- Standards Space Type OS:Rendering:Color, {4cbf1a19-a1d6-47b1-be2c-e0cb3239b580}, !- Handle @@ -6143,7 +6143,7 @@ OS:SpaceType, {79fe25cc-f18f-4c81-9067-4f1339143a11}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - Corridor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {79fe25cc-f18f-4c81-9067-4f1339143a11}, !- Handle @@ -6160,7 +6160,7 @@ OS:SpaceType, {882bc51d-c688-4e24-9ff9-084b2e7d2d7c}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - Corridor2; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {882bc51d-c688-4e24-9ff9-084b2e7d2d7c}, !- Handle @@ -6177,7 +6177,7 @@ OS:SpaceType, {f2d8c78a-d039-4674-aac1-32e4bde41f20}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - GuestRoom; !- Standards Space Type + guest room; !- Standards Space Type OS:Rendering:Color, {f2d8c78a-d039-4674-aac1-32e4bde41f20}, !- Handle @@ -6194,7 +6194,7 @@ OS:SpaceType, {bd7bd0ee-6bc9-4453-a45f-4450f4b9aa3c}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - GuestRoom2; !- Standards Space Type + guest room; !- Standards Space Type OS:SpaceType, {0e58dbf0-8037-11eb-9439-0242ac130002}, !- Handle @@ -6204,7 +6204,7 @@ OS:SpaceType, {bd7bd0ee-6bc9-4453-a45f-4450f4b9aa3c}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - GuestRoom8; !- Standards Space Type + guest room; !- Standards Space Type OS:Rendering:Color, {bd7bd0ee-6bc9-4453-a45f-4450f4b9aa3c}, !- Handle @@ -6221,7 +6221,7 @@ OS:SpaceType, {8d612775-c120-46de-8971-53be32c16a4e}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - GuestRoom3; !- Standards Space Type + guest room; !- Standards Space Type OS:Rendering:Color, {8d612775-c120-46de-8971-53be32c16a4e}, !- Handle @@ -6238,7 +6238,7 @@ OS:SpaceType, {847b4ee3-d01a-49ae-a246-fb522793e8ba}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - GuestRoom4; !- Standards Space Type + guest room; !- Standards Space Type OS:Rendering:Color, {847b4ee3-d01a-49ae-a246-fb522793e8ba}, !- Handle @@ -6255,7 +6255,7 @@ OS:SpaceType, {bbb88b17-fdc6-4280-a1e5-ebdc8292eba7}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - Kitchen; !- Standards Space Type + food preparation; !- Standards Space Type OS:Rendering:Color, {bbb88b17-fdc6-4280-a1e5-ebdc8292eba7}, !- Handle @@ -6272,7 +6272,7 @@ OS:SpaceType, {bc6be1c5-9868-4f47-82a8-d8744fb32b91}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - Laundry; !- Standards Space Type + laundry/washing; !- Standards Space Type OS:Rendering:Color, {bc6be1c5-9868-4f47-82a8-d8744fb32b91}, !- Handle @@ -6289,7 +6289,7 @@ OS:SpaceType, {b7dd911b-aef4-4967-897d-1f5ab22ba27b}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - Lobby; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {b7dd911b-aef4-4967-897d-1f5ab22ba27b}, !- Handle @@ -6306,7 +6306,7 @@ OS:SpaceType, {913d3e3f-2e56-4c91-928e-38f17d6c81fe}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - Mechanical; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {913d3e3f-2e56-4c91-928e-38f17d6c81fe}, !- Handle @@ -6323,7 +6323,7 @@ OS:SpaceType, {144eada1-1292-4b0a-ab18-5b2985bb8412}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - Retail; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {144eada1-1292-4b0a-ab18-5b2985bb8412}, !- Handle @@ -6340,7 +6340,7 @@ OS:SpaceType, {72698817-919d-4c15-b2f1-e7b195442ee8}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - Retail2; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {72698817-919d-4c15-b2f1-e7b195442ee8}, !- Handle @@ -6357,7 +6357,7 @@ OS:SpaceType, {e493b7d7-a50e-4baa-b7c9-945bc81bf348}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - Storage; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {e493b7d7-a50e-4baa-b7c9-945bc81bf348}, !- Handle diff --git a/data/geometry/ASHRAELargeOffice.osm b/data/geometry/ASHRAELargeOffice.osm index 4021fdaba2..e07db231c4 100644 --- a/data/geometry/ASHRAELargeOffice.osm +++ b/data/geometry/ASHRAELargeOffice.osm @@ -5635,7 +5635,7 @@ OS:SpaceType, {deec795f-0d5a-406a-9bf7-2a38ae96582c}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Office, !- Standards Building Type - WholeBuilding - Lg Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {deec795f-0d5a-406a-9bf7-2a38ae96582c}, !- Handle @@ -5652,7 +5652,7 @@ OS:SpaceType, {1662bc3b-58b7-4cf1-b5dd-0ccf3b1c396e}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Office, !- Standards Building Type - OfficeLarge Data Center; !- Standards Space Type + datacenter/low ite; !- Standards Space Type OS:Rendering:Color, {1662bc3b-58b7-4cf1-b5dd-0ccf3b1c396e}, !- Handle @@ -5669,7 +5669,7 @@ OS:SpaceType, {dfeef457-6cd1-40dc-aa16-7b1cfcb585e1}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Office, !- Standards Building Type - OfficeLarge Main Data Center; !- Standards Space Type + datacenter/high ite; !- Standards Space Type OS:Rendering:Color, {dfeef457-6cd1-40dc-aa16-7b1cfcb585e1}, !- Handle @@ -5686,7 +5686,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name , !- Standards Building Type - Plenum; !- Standards Space Type + plenum; !- Standards Space Type OS:SubSurface, {a165c732-31bf-48a6-a413-d61dc5ff3d07}, !- Handle diff --git a/data/geometry/ASHRAELargeOfficeDetailed.osm b/data/geometry/ASHRAELargeOfficeDetailed.osm index 21f2f13659..95e1dcd3ec 100644 --- a/data/geometry/ASHRAELargeOfficeDetailed.osm +++ b/data/geometry/ASHRAELargeOfficeDetailed.osm @@ -18477,7 +18477,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - OpenOffice; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {1387cc37-4d7b-4f7f-86b3-e285075a148e}, !- Handle @@ -18495,7 +18495,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - ClosedOffice; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {cc772eef-de54-43c2-b85a-a10de18e5b13}, !- Handle @@ -18513,7 +18513,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Elec/MechRoom; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {f95a3f05-079b-4b27-8005-df87c23246f2}, !- Handle @@ -18531,7 +18531,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Corridor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {4f50db8c-15e9-426f-83d2-9ec9581b4aa8}, !- Handle @@ -18549,7 +18549,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Restroom; !- Standards Space Type + restroom; !- Standards Space Type OS:Rendering:Color, {1708cbe5-533e-4dcd-bdfd-a7905b49eb3f}, !- Handle @@ -18567,7 +18567,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Lobby; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {51d0357b-8dcc-46a8-8147-6e4ae929de2d}, !- Handle @@ -18585,7 +18585,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Stair; !- Standards Space Type + stairwell; !- Standards Space Type OS:Rendering:Color, {5b4db05a-e3aa-4691-a828-be7c19730c34}, !- Handle @@ -18604,7 +18604,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Dining; !- Standards Space Type + dining; !- Standards Space Type OS:Rendering:Color, {81238171-1bb6-49b8-96f6-58b5e3fbf0f8}, !- Handle @@ -18622,7 +18622,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Conference; !- Standards Space Type + conference/meeting/multipurpose; !- Standards Space Type OS:Rendering:Color, {329a96ca-030a-4aa0-92d7-862dbb62dbda}, !- Handle @@ -18640,7 +18640,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Storage; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {69347753-25b6-4f5c-b66a-2d8ce0fc90d4}, !- Handle @@ -18658,7 +18658,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Classroom; !- Standards Space Type + classroom/lecture/training; !- Standards Space Type OS:Rendering:Color, {70112ab4-810d-4a54-933c-8dc9a21f3119}, !- Handle @@ -18676,7 +18676,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - BreakRoom; !- Standards Space Type + lounge/breakroom; !- Standards Space Type OS:Rendering:Color, {95ccf356-3dd3-40f5-8b41-746c84a8c446}, !- Handle @@ -18694,7 +18694,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - OfficeLarge Data Center; !- Standards Space Type + datacenter/low ite; !- Standards Space Type OS:Rendering:Color, {dfe7bc47-b47a-465d-8dfe-aac3a9a32494}, !- Handle @@ -18712,7 +18712,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - OfficeLarge Main Data Center; !- Standards Space Type + datacenter/high ite; !- Standards Space Type OS:Rendering:Color, {711e801a-193d-4b81-a8dc-027496c01cd2}, !- Handle diff --git a/data/geometry/ASHRAEMediumOffice.osm b/data/geometry/ASHRAEMediumOffice.osm index b377f9c93f..a99b08368c 100644 --- a/data/geometry/ASHRAEMediumOffice.osm +++ b/data/geometry/ASHRAEMediumOffice.osm @@ -4458,7 +4458,7 @@ OS:SpaceType, {507a5052-c6fa-4e80-96ea-d8413460cc49}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Office, !- Standards Building Type - WholeBuilding - Md Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {507a5052-c6fa-4e80-96ea-d8413460cc49}, !- Handle @@ -4475,7 +4475,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name , !- Standards Building Type - Plenum; !- Standards Space Type + plenum; !- Standards Space Type OS:SubSurface, {bc65ca32-39bf-48a6-a1cd-d61dc5fd3db7}, !- Handle diff --git a/data/geometry/ASHRAEMediumOfficeDetailed.osm b/data/geometry/ASHRAEMediumOfficeDetailed.osm index 0c30c5aac8..a9346a445f 100644 --- a/data/geometry/ASHRAEMediumOfficeDetailed.osm +++ b/data/geometry/ASHRAEMediumOfficeDetailed.osm @@ -12912,7 +12912,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - MediumOffice - OpenOffice; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {eb522dc0-a29a-484b-bcb5-8ff1eef34cb0}, !- Handle @@ -12930,7 +12930,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - MediumOffice - ClosedOffice; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {95b38b88-279a-4835-9d48-89da8042a72e}, !- Handle @@ -12948,7 +12948,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - MediumOffice - Classroom; !- Standards Space Type + classroom/lecture/training; !- Standards Space Type OS:Rendering:Color, {687dbd99-171a-4640-8f08-41d2fb660847}, !- Handle @@ -12966,7 +12966,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - MediumOffice - Conference; !- Standards Space Type + conference/meeting/multipurpose; !- Standards Space Type OS:Rendering:Color, {af24da99-6231-473d-a4ee-98e18dec0b26}, !- Handle @@ -12984,7 +12984,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - MediumOffice - Storage; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {b88bdaea-5220-4f5f-8918-1277d0cb2bef}, !- Handle @@ -13002,7 +13002,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - MediumOffice - Corridor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {b365ceb4-b39a-4c6e-be79-d8570755bc74}, !- Handle @@ -13020,7 +13020,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - MediumOffice - Dining; !- Standards Space Type + dining; !- Standards Space Type OS:Rendering:Color, {b3caefa0-edb1-4409-bb19-0da21d57131f}, !- Handle @@ -13038,7 +13038,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - MediumOffice - Lobby; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {a733da76-dbef-4059-a66c-7a259eba3233}, !- Handle @@ -13056,7 +13056,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - MediumOffice - Elec/MechRoom; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {22c28617-85f5-4120-8ce3-46c49fba1406}, !- Handle @@ -13074,7 +13074,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - MediumOffice - Stair; !- Standards Space Type + stairwell; !- Standards Space Type OS:Rendering:Color, {7c21f5c0-74ce-48f5-ac78-18545b8bd117}, !- Handle @@ -13092,7 +13092,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - MediumOffice - Restroom; !- Standards Space Type + restroom; !- Standards Space Type OS:Rendering:Color, {0aa78b18-9198-4ff7-ba83-ca611bc87c18}, !- Handle diff --git a/data/geometry/ASHRAEMidriseApartment.osm b/data/geometry/ASHRAEMidriseApartment.osm index 100e7a1f25..f22d6261d7 100644 --- a/data/geometry/ASHRAEMidriseApartment.osm +++ b/data/geometry/ASHRAEMidriseApartment.osm @@ -6427,7 +6427,7 @@ OS:SpaceType, {fa8e349c-6a95-4319-9ad6-a8ad113788c0}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name MidriseApartment, !- Standards Building Type - Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {fa8e349c-6a95-4319-9ad6-a8ad113788c0}, !- Handle @@ -6444,7 +6444,7 @@ OS:SpaceType, {f3a79c8b-753a-4d43-800b-7b41ca42acc5}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name MidriseApartment, !- Standards Building Type - Corridor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {f3a79c8b-753a-4d43-800b-7b41ca42acc5}, !- Handle @@ -6461,7 +6461,7 @@ OS:SpaceType, {dd6acbd6-13bf-4848-b85d-4393f69a5e36}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name MidriseApartment, !- Standards Building Type - Corridor_topfloor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {dd6acbd6-13bf-4848-b85d-4393f69a5e36}, !- Handle @@ -6478,7 +6478,7 @@ OS:SpaceType, {c02af3d7-2b46-4b65-ba55-43b9b2109d80}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name MidriseApartment, !- Standards Building Type - Apartment; !- Standards Space Type + multifamily; !- Standards Space Type OS:Rendering:Color, {c02af3d7-2b46-4b65-ba55-43b9b2109d80}, !- Handle @@ -6495,7 +6495,7 @@ OS:SpaceType, {56644041-06bb-44dd-ad1a-4cc4126ec016}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name MidriseApartment, !- Standards Building Type - Apartment_topfloor_WE; !- Standards Space Type + multifamily; !- Standards Space Type OS:Rendering:Color, {56644041-06bb-44dd-ad1a-4cc4126ec016}, !- Handle @@ -6512,7 +6512,7 @@ OS:SpaceType, {cda85b10-df59-4b24-836d-e9fea30febfd}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name MidriseApartment, !- Standards Building Type - Apartment_topfloor_NS; !- Standards Space Type + multifamily; !- Standards Space Type OS:Rendering:Color, {cda85b10-df59-4b24-836d-e9fea30febfd}, !- Handle diff --git a/data/geometry/ASHRAEOutpatient.osm b/data/geometry/ASHRAEOutpatient.osm index 1b5cccdf9d..b56db92215 100644 --- a/data/geometry/ASHRAEOutpatient.osm +++ b/data/geometry/ASHRAEOutpatient.osm @@ -32849,7 +32849,7 @@ OS:SpaceType, {54db1ed1-80e8-486f-899f-035e0e97239f}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Anesthesia; !- Standards Space Type + exam/treatment; !- Standards Space Type OS:Rendering:Color, {54db1ed1-80e8-486f-899f-035e0e97239f}, !- Handle @@ -32866,7 +32866,7 @@ OS:SpaceType, {df814a82-3e83-4733-b2cb-dcb620901a69}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - BioHazard; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {df814a82-3e83-4733-b2cb-dcb620901a69}, !- Handle @@ -32883,7 +32883,7 @@ OS:SpaceType, {81ab0734-072e-4c44-8dc3-3e9acde5d403}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Cafe; !- Standards Space Type + dining; !- Standards Space Type OS:Rendering:Color, {81ab0734-072e-4c44-8dc3-3e9acde5d403}, !- Handle @@ -32900,7 +32900,7 @@ OS:SpaceType, {5192d441-bb7c-41bf-b24a-ddcdeab8b747}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - CleanWork; !- Standards Space Type + exam/treatment; !- Standards Space Type OS:Rendering:Color, {5192d441-bb7c-41bf-b24a-ddcdeab8b747}, !- Handle @@ -32917,7 +32917,7 @@ OS:SpaceType, {7602e6ab-d574-4523-819b-9dbc607dd42d}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Conference; !- Standards Space Type + conference/meeting/multipurpose; !- Standards Space Type OS:Rendering:Color, {7602e6ab-d574-4523-819b-9dbc607dd42d}, !- Handle @@ -32934,7 +32934,7 @@ OS:SpaceType, {7914d0d4-bf0c-4db6-a57d-430cdc4f66e5}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - DressingRoom; !- Standards Space Type + dressing room; !- Standards Space Type OS:Rendering:Color, {7914d0d4-bf0c-4db6-a57d-430cdc4f66e5}, !- Handle @@ -32951,7 +32951,7 @@ OS:SpaceType, {cc039449-da7a-4737-abda-1ed339cc2113}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Elec/MechRoom; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {cc039449-da7a-4737-abda-1ed339cc2113}, !- Handle @@ -32968,7 +32968,7 @@ OS:SpaceType, {3f5f4d2b-499b-44c9-9d63-c3e20024f78a}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - ElevatorPumpRoom; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {3f5f4d2b-499b-44c9-9d63-c3e20024f78a}, !- Handle @@ -32985,7 +32985,7 @@ OS:SpaceType, {289ef889-859b-4541-9e5c-5c8c30d7385b}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Exam; !- Standards Space Type + exam/treatment; !- Standards Space Type OS:Rendering:Color, {289ef889-859b-4541-9e5c-5c8c30d7385b}, !- Handle @@ -33002,7 +33002,7 @@ OS:SpaceType, {ba4eb9cb-3586-4e65-8541-aa3bc11a1870}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Hall; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {ba4eb9cb-3586-4e65-8541-aa3bc11a1870}, !- Handle @@ -33019,7 +33019,7 @@ OS:SpaceType, {f91b1f68-0eb5-4dc0-bed8-27c4961be65c}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Hall_infil; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {f91b1f68-0eb5-4dc0-bed8-27c4961be65c}, !- Handle @@ -33036,7 +33036,7 @@ OS:SpaceType, {a51b5b7a-405b-44dd-bfab-772935555963}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - IT_Room; !- Standards Space Type + datacenter/low ite; !- Standards Space Type OS:Rendering:Color, {a51b5b7a-405b-44dd-bfab-772935555963}, !- Handle @@ -33053,7 +33053,7 @@ OS:SpaceType, {c27e1678-d235-4fee-8262-bb1ce2382bce}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Janitor; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {c27e1678-d235-4fee-8262-bb1ce2382bce}, !- Handle @@ -33070,7 +33070,7 @@ OS:SpaceType, {bb1dfeec-30eb-452a-b65f-b21605006fef}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Lobby; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {bb1dfeec-30eb-452a-b65f-b21605006fef}, !- Handle @@ -33087,7 +33087,7 @@ OS:SpaceType, {26d485d2-cba6-4799-b13e-18c565e3e3cf}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - LockerRoom; !- Standards Space Type + locker room; !- Standards Space Type OS:Rendering:Color, {26d485d2-cba6-4799-b13e-18c565e3e3cf}, !- Handle @@ -33104,7 +33104,7 @@ OS:SpaceType, {b8e825b7-b2c6-405c-80c9-b3397e74a948}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Lounge; !- Standards Space Type + lounge/breakroom; !- Standards Space Type OS:Rendering:Color, {b8e825b7-b2c6-405c-80c9-b3397e74a948}, !- Handle @@ -33121,7 +33121,7 @@ OS:SpaceType, {0395a4ae-877c-4061-af54-9cd5b80d45b8}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - MRI; !- Standards Space Type + imaging; !- Standards Space Type OS:Rendering:Color, {0395a4ae-877c-4061-af54-9cd5b80d45b8}, !- Handle @@ -33138,7 +33138,7 @@ OS:SpaceType, {ace49159-7d8c-4a75-8dc7-e541dfa842c4}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - MRI_Control; !- Standards Space Type + imaging; !- Standards Space Type OS:Rendering:Color, {ace49159-7d8c-4a75-8dc7-e541dfa842c4}, !- Handle @@ -33155,7 +33155,7 @@ OS:SpaceType, {77acad34-fb1e-4cf2-8618-5fc821e8f9b8}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - MedGas; !- Standards Space Type + exam/treatment; !- Standards Space Type OS:Rendering:Color, {77acad34-fb1e-4cf2-8618-5fc821e8f9b8}, !- Handle @@ -33172,7 +33172,7 @@ OS:SpaceType, {35a9786d-f066-4808-be66-249cfd71d65f}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - NurseStation; !- Standards Space Type + nurses station; !- Standards Space Type OS:Rendering:Color, {35a9786d-f066-4808-be66-249cfd71d65f}, !- Handle @@ -33189,7 +33189,7 @@ OS:SpaceType, {4cf0a6c9-ba59-44d7-8119-29d3da151dce}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - OR; !- Standards Space Type + operating room; !- Standards Space Type OS:Rendering:Color, {4cf0a6c9-ba59-44d7-8119-29d3da151dce}, !- Handle @@ -33206,7 +33206,7 @@ OS:SpaceType, {7c8180e8-b8e3-4750-9762-7b69c07b8647}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {7c8180e8-b8e3-4750-9762-7b69c07b8647}, !- Handle @@ -33223,7 +33223,7 @@ OS:SpaceType, {d6c6ee5b-09e3-41f0-8e1d-8165c403885c}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - PACU; !- Standards Space Type + patient room; !- Standards Space Type OS:Rendering:Color, {d6c6ee5b-09e3-41f0-8e1d-8165c403885c}, !- Handle @@ -33240,7 +33240,7 @@ OS:SpaceType, {3202c1e4-552a-47fb-8849-e9ff9f27e91d}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - PhysicalTherapy; !- Standards Space Type + physical therapy; !- Standards Space Type OS:Rendering:Color, {3202c1e4-552a-47fb-8849-e9ff9f27e91d}, !- Handle @@ -33257,7 +33257,7 @@ OS:SpaceType, {a5da6dba-3010-4e50-a08d-c8c1acce154d}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - PreOp; !- Standards Space Type + operating room; !- Standards Space Type OS:Rendering:Color, {a5da6dba-3010-4e50-a08d-c8c1acce154d}, !- Handle @@ -33274,7 +33274,7 @@ OS:SpaceType, {6701b661-88af-4156-b574-546ca60f54f3}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - ProcedureRoom; !- Standards Space Type + operating room; !- Standards Space Type OS:Rendering:Color, {6701b661-88af-4156-b574-546ca60f54f3}, !- Handle @@ -33291,7 +33291,7 @@ OS:SpaceType, {4b78b7ad-f448-49f3-9fd5-d2818cf20fb6}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Soil Work; !- Standards Space Type + exam/treatment; !- Standards Space Type OS:Rendering:Color, {4b78b7ad-f448-49f3-9fd5-d2818cf20fb6}, !- Handle @@ -33308,7 +33308,7 @@ OS:SpaceType, {b4cea8ff-7836-4a99-a993-03779f4aae86}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Stair; !- Standards Space Type + stairwell; !- Standards Space Type OS:Rendering:Color, {b4cea8ff-7836-4a99-a993-03779f4aae86}, !- Handle @@ -33325,7 +33325,7 @@ OS:SpaceType, {da52f6e0-3816-4e10-945c-7718ea541018}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Toilet; !- Standards Space Type + restroom; !- Standards Space Type OS:Rendering:Color, {da52f6e0-3816-4e10-945c-7718ea541018}, !- Handle @@ -33342,7 +33342,7 @@ OS:SpaceType, {e3e7be2a-044d-4f10-9603-da2aa55c6110}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Xray; !- Standards Space Type + imaging; !- Standards Space Type OS:Rendering:Color, {e3e7be2a-044d-4f10-9603-da2aa55c6110}, !- Handle @@ -33359,7 +33359,7 @@ OS:SpaceType, {7c28a49a-f63e-46c6-9dd3-e4c2cbe8d622}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Reception; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {7c28a49a-f63e-46c6-9dd3-e4c2cbe8d622}, !- Handle @@ -33376,7 +33376,7 @@ OS:SpaceType, {158cc556-36f0-4c04-b601-3a3ac73f51ac}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Outpatient, !- Standards Building Type - Undeveloped; !- Standards Space Type + shaft; !- Standards Space Type OS:Rendering:Color, {158cc556-36f0-4c04-b601-3a3ac73f51ac}, !- Handle diff --git a/data/geometry/ASHRAEPrimarySchool.osm b/data/geometry/ASHRAEPrimarySchool.osm index 8ceac90b42..9db9b0850c 100644 --- a/data/geometry/ASHRAEPrimarySchool.osm +++ b/data/geometry/ASHRAEPrimarySchool.osm @@ -6743,7 +6743,7 @@ OS:SpaceType, {507a5052-c6fa-4e80-96ea-d8413460cc49}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name PrimarySchool, !- Standards Building Type - Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {507a5052-c6fa-4e80-96ea-d8413460cc49}, !- Handle @@ -6760,7 +6760,7 @@ OS:SpaceType, {de34b478-3803-4e06-a6b0-94fb668f99b0}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name PrimarySchool, !- Standards Building Type - Lobby; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {de34b478-3803-4e06-a6b0-94fb668f99b0}, !- Handle @@ -6777,7 +6777,7 @@ OS:SpaceType, {3a0f162a-46fe-45d9-8a9b-011bcdf88e16}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name PrimarySchool, !- Standards Building Type - Gym; !- Standards Space Type + exercise area; !- Standards Space Type OS:Rendering:Color, {3a0f162a-46fe-45d9-8a9b-011bcdf88e16}, !- Handle @@ -6794,7 +6794,7 @@ OS:SpaceType, {69c18cae-9d2f-4864-9c57-e3dd9c93faac}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name PrimarySchool, !- Standards Building Type - Mechanical; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {69c18cae-9d2f-4864-9c57-e3dd9c93faac}, !- Handle @@ -6811,7 +6811,7 @@ OS:SpaceType, {13d8edca-f17b-4a9f-8402-de08ca4175c3}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name PrimarySchool, !- Standards Building Type - Cafeteria; !- Standards Space Type + dining; !- Standards Space Type OS:Rendering:Color, {13d8edca-f17b-4a9f-8402-de08ca4175c3}, !- Handle @@ -6828,7 +6828,7 @@ OS:SpaceType, {4b81ad58-3059-4888-a5f0-4667974bbc33}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name PrimarySchool, !- Standards Building Type - Kitchen; !- Standards Space Type + food preparation; !- Standards Space Type OS:Rendering:Color, {4b81ad58-3059-4888-a5f0-4667974bbc33}, !- Handle @@ -6845,7 +6845,7 @@ OS:SpaceType, {5f90fb4b-00a3-4f7c-9da6-bb0d2f6c8dbd}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name PrimarySchool, !- Standards Building Type - Restroom; !- Standards Space Type + restroom; !- Standards Space Type OS:Rendering:Color, {5f90fb4b-00a3-4f7c-9da6-bb0d2f6c8dbd}, !- Handle @@ -6862,7 +6862,7 @@ OS:SpaceType, {35d16a43-528e-4bb0-b366-0307cf03d08b}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name PrimarySchool, !- Standards Building Type - Corridor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {35d16a43-528e-4bb0-b366-0307cf03d08b}, !- Handle @@ -6879,7 +6879,7 @@ OS:SpaceType, {b33dba6b-b3dc-431f-999e-546c9d49159b}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name PrimarySchool, !- Standards Building Type - Classroom; !- Standards Space Type + classroom/lecture/training; !- Standards Space Type OS:Rendering:Color, {b33dba6b-b3dc-431f-999e-546c9d49159b}, !- Handle @@ -6896,7 +6896,7 @@ OS:SpaceType, {5523923f-6128-48f7-b361-279399792ff5}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name PrimarySchool, !- Standards Building Type - ComputerRoom; !- Standards Space Type + datacenter/low ite; !- Standards Space Type OS:Rendering:Color, {5523923f-6128-48f7-b361-279399792ff5}, !- Handle @@ -6913,7 +6913,7 @@ OS:SpaceType, {b36531a2-a0fd-4d78-a02d-531890427a29}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name PrimarySchool, !- Standards Building Type - Library; !- Standards Space Type + library; !- Standards Space Type OS:Rendering:Color, {b36531a2-a0fd-4d78-a02d-531890427a29}, !- Handle diff --git a/data/geometry/ASHRAEQuickServiceRestaurant.osm b/data/geometry/ASHRAEQuickServiceRestaurant.osm index de36fe8278..1bd2cd4099 100644 --- a/data/geometry/ASHRAEQuickServiceRestaurant.osm +++ b/data/geometry/ASHRAEQuickServiceRestaurant.osm @@ -790,7 +790,7 @@ OS:SpaceType, {507a5052-c6fa-4e80-96ea-d8413460cc49}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name QuickServiceRestaurant, !- Standards Building Type - Dining; !- Standards Space Type + dining; !- Standards Space Type OS:Rendering:Color, {507a5052-c6fa-4e80-96ea-d8413460cc49}, !- Handle @@ -807,7 +807,7 @@ OS:SpaceType, {de34b478-3803-4e06-a6b0-94fb668f99b0}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name QuickServiceRestaurant, !- Standards Building Type - Kitchen; !- Standards Space Type + food preparation; !- Standards Space Type OS:Rendering:Color, {de34b478-3803-4e06-a6b0-94fb668f99b0}, !- Handle @@ -824,7 +824,7 @@ OS:SpaceType, {3a0f162a-46fe-45d9-8a9b-011bcdf88e16}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name QuickServiceRestaurant, !- Standards Building Type - Attic; !- Standards Space Type + attic; !- Standards Space Type OS:Rendering:Color, {3a0f162a-46fe-45d9-8a9b-011bcdf88e16}, !- Handle diff --git a/data/geometry/ASHRAERetailStripmall.osm b/data/geometry/ASHRAERetailStripmall.osm index e537ead215..348e7f68e7 100644 --- a/data/geometry/ASHRAERetailStripmall.osm +++ b/data/geometry/ASHRAERetailStripmall.osm @@ -2969,7 +2969,7 @@ OS:SpaceType, {e185e757-f684-4834-8de5-a992fdf9cc51}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name StripMall, !- Standards Building Type - Strip mall - type 1; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {e185e757-f684-4834-8de5-a992fdf9cc51}, !- Handle @@ -2986,7 +2986,7 @@ OS:SpaceType, {1609d3a3-991f-4f05-945e-2e061cebaa9a}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name StripMall, !- Standards Building Type - Strip mall - type 2; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {1609d3a3-991f-4f05-945e-2e061cebaa9a}, !- Handle @@ -3003,7 +3003,7 @@ OS:SpaceType, {99a89640-fa94-4223-86ac-5730ec03257d}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name StripMall, !- Standards Building Type - Strip mall - type 3; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {99a89640-fa94-4223-86ac-5730ec03257d}, !- Handle diff --git a/data/geometry/ASHRAESecondarySchool.osm b/data/geometry/ASHRAESecondarySchool.osm index 70a5aa3d1b..6aaf60c653 100644 --- a/data/geometry/ASHRAESecondarySchool.osm +++ b/data/geometry/ASHRAESecondarySchool.osm @@ -13503,7 +13503,7 @@ OS:SpaceType, {3700293b-c86a-41bd-87a7-218d799d774f}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SecondarySchool, !- Standards Building Type - Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {3700293b-c86a-41bd-87a7-218d799d774f}, !- Handle @@ -13520,7 +13520,7 @@ OS:SpaceType, {d046d443-7b8c-4894-aeb6-0ae35f445413}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SecondarySchool, !- Standards Building Type - Lobby; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {d046d443-7b8c-4894-aeb6-0ae35f445413}, !- Handle @@ -13537,7 +13537,7 @@ OS:SpaceType, {70cd8f25-45c2-4b6b-bca5-5a00efcd1035}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SecondarySchool, !- Standards Building Type - Gym; !- Standards Space Type + exercise area; !- Standards Space Type OS:Rendering:Color, {70cd8f25-45c2-4b6b-bca5-5a00efcd1035}, !- Handle @@ -13554,7 +13554,7 @@ OS:SpaceType, {a6eb1313-91d2-4450-a3fa-986d23c94af6}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SecondarySchool, !- Standards Building Type - Mechanical; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {a6eb1313-91d2-4450-a3fa-986d23c94af6}, !- Handle @@ -13571,7 +13571,7 @@ OS:SpaceType, {228ad953-9b82-41ee-9d04-4d928aecc05b}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SecondarySchool, !- Standards Building Type - Cafeteria; !- Standards Space Type + dining; !- Standards Space Type OS:Rendering:Color, {228ad953-9b82-41ee-9d04-4d928aecc05b}, !- Handle @@ -13588,7 +13588,7 @@ OS:SpaceType, {437d0173-cbd1-47be-a7e7-bde954d25d85}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SecondarySchool, !- Standards Building Type - Kitchen; !- Standards Space Type + food preparation; !- Standards Space Type OS:Rendering:Color, {437d0173-cbd1-47be-a7e7-bde954d25d85}, !- Handle @@ -13605,7 +13605,7 @@ OS:SpaceType, {56cd9005-3fad-4747-b686-d7129eed429c}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SecondarySchool, !- Standards Building Type - Restroom; !- Standards Space Type + restroom; !- Standards Space Type OS:Rendering:Color, {56cd9005-3fad-4747-b686-d7129eed429c}, !- Handle @@ -13622,7 +13622,7 @@ OS:SpaceType, {3c4285f1-84f8-4a3d-ab1b-3bbab5bb320c}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SecondarySchool, !- Standards Building Type - Auditorium; !- Standards Space Type + audience seating; !- Standards Space Type OS:Rendering:Color, {3c4285f1-84f8-4a3d-ab1b-3bbab5bb320c}, !- Handle @@ -13639,7 +13639,7 @@ OS:SpaceType, {cf44149e-79aa-4ce0-b48c-da5493e927ba}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SecondarySchool, !- Standards Building Type - Library; !- Standards Space Type + library; !- Standards Space Type OS:Rendering:Color, {cf44149e-79aa-4ce0-b48c-da5493e927ba}, !- Handle @@ -13656,7 +13656,7 @@ OS:SpaceType, {80464b57-3b05-4aa7-94b0-9010ce0a69e2}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SecondarySchool, !- Standards Building Type - Corridor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {80464b57-3b05-4aa7-94b0-9010ce0a69e2}, !- Handle @@ -13673,7 +13673,7 @@ OS:SpaceType, {cb3854c6-e817-4be8-a30e-8daa0a5bf51f}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SecondarySchool, !- Standards Building Type - Classroom; !- Standards Space Type + classroom/lecture/training; !- Standards Space Type OS:Rendering:Color, {cb3854c6-e817-4be8-a30e-8daa0a5bf51f}, !- Handle @@ -13690,7 +13690,7 @@ OS:SpaceType, {27d027f7-2a45-4c89-a187-5aae2be88f12}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SecondarySchool, !- Standards Building Type - ComputerRoom; !- Standards Space Type + datacenter/low ite; !- Standards Space Type OS:Rendering:Color, {27d027f7-2a45-4c89-a187-5aae2be88f12}, !- Handle diff --git a/data/geometry/ASHRAESmallDataCenterHighITE.osm b/data/geometry/ASHRAESmallDataCenterHighITE.osm index ee9673c1bd..c4cbafbb4f 100644 --- a/data/geometry/ASHRAESmallDataCenterHighITE.osm +++ b/data/geometry/ASHRAESmallDataCenterHighITE.osm @@ -136,7 +136,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template SmallDataCenterHighITE, !- Standards Building Type - ComputerRoom; !- Standards Space Type + datacenter/low ite; !- Standards Space Type OS:ThermalZone, {d38545b2-2961-40d7-b81d-d37499da0447}, !- Handle diff --git a/data/geometry/ASHRAESmallDataCenterLowITE.osm b/data/geometry/ASHRAESmallDataCenterLowITE.osm index fcbac7cf0e..05c253fb54 100644 --- a/data/geometry/ASHRAESmallDataCenterLowITE.osm +++ b/data/geometry/ASHRAESmallDataCenterLowITE.osm @@ -136,7 +136,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template SmallDataCenterLowITE, !- Standards Building Type - ComputerRoom; !- Standards Space Type + datacenter/low ite; !- Standards Space Type OS:ThermalZone, {ae5f6744-0515-4e74-8da9-8d078d2bb425}, !- Handle diff --git a/data/geometry/ASHRAESmallHotel.osm b/data/geometry/ASHRAESmallHotel.osm index 9d3c10d109..ab5227a63f 100644 --- a/data/geometry/ASHRAESmallHotel.osm +++ b/data/geometry/ASHRAESmallHotel.osm @@ -17087,7 +17087,7 @@ OS:SpaceType, {7d683ed9-f4a8-41fc-a335-cbd38420323e}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - Corridor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {7d683ed9-f4a8-41fc-a335-cbd38420323e}, !- Handle @@ -17104,7 +17104,7 @@ OS:SpaceType, {6a61cc16-c155-4fa3-8490-fab026fc5c9c}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - Corridor4; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {6a61cc16-c155-4fa3-8490-fab026fc5c9c}, !- Handle @@ -17121,7 +17121,7 @@ OS:SpaceType, {2937517b-f3bc-49e6-8db4-a06dca2d2676}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - Elec/MechRoom; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {2937517b-f3bc-49e6-8db4-a06dca2d2676}, !- Handle @@ -17138,7 +17138,7 @@ OS:SpaceType, {543c0443-4c68-49bd-b7b8-7a7c4a10aed0}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - ElevatorCore; !- Standards Space Type + shaft; !- Standards Space Type OS:Rendering:Color, {543c0443-4c68-49bd-b7b8-7a7c4a10aed0}, !- Handle @@ -17155,7 +17155,7 @@ OS:SpaceType, {0d4d25c9-ed08-4d2a-bc60-7294b3c705d0}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - ElevatorCore4; !- Standards Space Type + shaft; !- Standards Space Type OS:Rendering:Color, {0d4d25c9-ed08-4d2a-bc60-7294b3c705d0}, !- Handle @@ -17172,7 +17172,7 @@ OS:SpaceType, {de36faca-43bf-4c9f-adef-9686a2c25887}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - StaffLounge; !- Standards Space Type + lounge/breakroom; !- Standards Space Type OS:Rendering:Color, {de36faca-43bf-4c9f-adef-9686a2c25887}, !- Handle @@ -17189,7 +17189,7 @@ OS:SpaceType, {d705d106-efda-4513-807b-fec73e85686d}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - Exercise; !- Standards Space Type + exercise area; !- Standards Space Type OS:Rendering:Color, {d705d106-efda-4513-807b-fec73e85686d}, !- Handle @@ -17206,7 +17206,7 @@ OS:SpaceType, {2c32f817-541a-4b1a-acf2-a74a3a8e7852}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - GuestLounge; !- Standards Space Type + lounge/breakroom; !- Standards Space Type OS:Rendering:Color, {2c32f817-541a-4b1a-acf2-a74a3a8e7852}, !- Handle @@ -17223,7 +17223,7 @@ OS:SpaceType, {9614ba9b-7b88-49ef-8e4d-52b366028dfa}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {9614ba9b-7b88-49ef-8e4d-52b366028dfa}, !- Handle @@ -17240,7 +17240,7 @@ OS:SpaceType, {a826c61c-092a-4a2f-862c-7073948c6ae1}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - Stair; !- Standards Space Type + stairwell; !- Standards Space Type OS:Rendering:Color, {a826c61c-092a-4a2f-862c-7073948c6ae1}, !- Handle @@ -17257,7 +17257,7 @@ OS:SpaceType, {74043f3f-de88-469b-b933-3d740474db6e}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - Stair4; !- Standards Space Type + stairwell; !- Standards Space Type OS:Rendering:Color, {74043f3f-de88-469b-b933-3d740474db6e}, !- Handle @@ -17274,7 +17274,7 @@ OS:SpaceType, {b4b4b093-ef06-4b4c-a16a-c09ae1c34986}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - Storage; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {b4b4b093-ef06-4b4c-a16a-c09ae1c34986}, !- Handle @@ -17291,7 +17291,7 @@ OS:SpaceType, {850b24a9-8e44-4b0c-9a4a-a8b60aec94b9}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - Storage4Front; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {850b24a9-8e44-4b0c-9a4a-a8b60aec94b9}, !- Handle @@ -17308,7 +17308,7 @@ OS:SpaceType, {6ae11d02-0af6-46c1-a013-620d4abc6322}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - Storage4Rear; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {6ae11d02-0af6-46c1-a013-620d4abc6322}, !- Handle @@ -17325,7 +17325,7 @@ OS:SpaceType, {ca3accbe-1941-4be5-9e8c-d723e688a598}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - GuestRoom123Occ; !- Standards Space Type + guest room; !- Standards Space Type OS:Rendering:Color, {ca3accbe-1941-4be5-9e8c-d723e688a598}, !- Handle @@ -17342,7 +17342,7 @@ OS:SpaceType, {70aad15d-93e8-47bc-9693-e49c41534fff}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - GuestRoom123Vac; !- Standards Space Type + guest room; !- Standards Space Type OS:Rendering:Color, {70aad15d-93e8-47bc-9693-e49c41534fff}, !- Handle @@ -17359,7 +17359,7 @@ OS:SpaceType, {df829925-91ed-40ec-a27f-e1ea4b1336d0}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - GuestRoom4Occ; !- Standards Space Type + guest room; !- Standards Space Type OS:Rendering:Color, {df829925-91ed-40ec-a27f-e1ea4b1336d0}, !- Handle @@ -17376,7 +17376,7 @@ OS:SpaceType, {dac722f2-8b7c-4241-adf6-012b8484f680}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - GuestRoom4Vac; !- Standards Space Type + guest room; !- Standards Space Type OS:Rendering:Color, {dac722f2-8b7c-4241-adf6-012b8484f680}, !- Handle @@ -17393,7 +17393,7 @@ OS:SpaceType, {dd6df320-66da-4275-9115-581f030b5c7e}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - Laundry; !- Standards Space Type + laundry/washing; !- Standards Space Type OS:Rendering:Color, {dd6df320-66da-4275-9115-581f030b5c7e}, !- Handle @@ -17410,7 +17410,7 @@ OS:SpaceType, {0e071a67-4cf9-4ebb-9a3a-87900b204b7b}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - Mechanical; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {0e071a67-4cf9-4ebb-9a3a-87900b204b7b}, !- Handle @@ -17427,7 +17427,7 @@ OS:SpaceType, {f64a4379-5791-4680-a07c-63d67ed014ec}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - Meeting; !- Standards Space Type + conference/meeting/multipurpose; !- Standards Space Type OS:Rendering:Color, {f64a4379-5791-4680-a07c-63d67ed014ec}, !- Handle @@ -17444,7 +17444,7 @@ OS:SpaceType, {d87591c7-14ef-4876-8438-9c602dc80c76}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - PublicRestroom; !- Standards Space Type + restroom; !- Standards Space Type OS:Rendering:Color, {d87591c7-14ef-4876-8438-9c602dc80c76}, !- Handle diff --git a/data/geometry/ASHRAESmallOffice.osm b/data/geometry/ASHRAESmallOffice.osm index 2bc501e3ef..9c3bad26e2 100644 --- a/data/geometry/ASHRAESmallOffice.osm +++ b/data/geometry/ASHRAESmallOffice.osm @@ -1835,7 +1835,7 @@ OS:SpaceType, {75385b6d-b97f-430d-8c39-23fe5b927d8a}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Office, !- Standards Building Type - WholeBuilding - Sm Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {75385b6d-b97f-430d-8c39-23fe5b927d8a}, !- Handle @@ -1852,7 +1852,7 @@ OS:SpaceType, {996c5881-2074-43c3-865a-a3c1283bbb9c}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Office, !- Standards Building Type - Attic; !- Standards Space Type + attic; !- Standards Space Type OS:Rendering:Color, {996c5881-2074-43c3-865a-a3c1283bbb9c}, !- Handle diff --git a/data/geometry/ASHRAESmallOfficeDetailed.osm b/data/geometry/ASHRAESmallOfficeDetailed.osm index 5cc6d3826b..db6199744d 100644 --- a/data/geometry/ASHRAESmallOfficeDetailed.osm +++ b/data/geometry/ASHRAESmallOfficeDetailed.osm @@ -4371,7 +4371,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - SmallOffice - Attic; !- Standards Space Type + attic; !- Standards Space Type OS:Rendering:Color, {0e2c7c7b-5d29-4b67-8b76-6e000891c8e2}, !- Handle @@ -4389,7 +4389,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - SmallOffice - OpenOffice; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {6da57b8c-46fd-4274-b97f-db06a942dfd8}, !- Handle @@ -4407,7 +4407,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - SmallOffice - ClosedOffice; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {58ddad7a-f214-4f61-9550-8655e973894a}, !- Handle @@ -4439,7 +4439,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - SmallOffice - Storage; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {dc376b19-b9ed-4763-82e3-b08274971093}, !- Handle @@ -4457,7 +4457,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - SmallOffice - Corridor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {2b050801-386a-4014-bcfb-1c0716e4f9a4}, !- Handle @@ -4475,7 +4475,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - SmallOffice - Restroom; !- Standards Space Type + restroom; !- Standards Space Type OS:Rendering:Color, {f7e3d7f9-cc2c-421f-b786-ddb373f1e608}, !- Handle @@ -4493,7 +4493,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - SmallOffice - Lobby; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {b8ce435c-7c1d-4617-874e-e45d9dba881a}, !- Handle @@ -4511,7 +4511,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - SmallOffice - Conference; !- Standards Space Type + conference/meeting/multipurpose; !- Standards Space Type OS:Rendering:Color, {a33fce9b-9840-4251-8e37-99b269931de4}, !- Handle @@ -4529,7 +4529,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - SmallOffice - Elec/MechRoom; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {2f523f3e-fb20-40d6-bc4a-14b65d9eb47b}, !- Handle @@ -4547,7 +4547,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - SmallOffice - Stair; !- Standards Space Type + stairwell; !- Standards Space Type OS:Rendering:Color, {414e245c-ae4b-4d32-a008-f307b1a150c1}, !- Handle diff --git a/data/geometry/ASHRAESuperMarket.osm b/data/geometry/ASHRAESuperMarket.osm index 0a856eeceb..1455c58f22 100644 --- a/data/geometry/ASHRAESuperMarket.osm +++ b/data/geometry/ASHRAESuperMarket.osm @@ -2027,7 +2027,7 @@ OS:SpaceType, {1ae07daf-5bd4-486f-9e1c-6802de433785}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Sales; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {ecb548af-f353-4b26-b9c6-a1416bd565d2}, !- Handle @@ -2044,7 +2044,7 @@ OS:SpaceType, {84fe7a3a-9487-439f-aceb-8a7d41ad4bbf}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Produce; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {651fc774-28aa-4409-84d3-4126e05a54b2}, !- Handle @@ -2061,7 +2061,7 @@ OS:SpaceType, {57ec9698-3b85-45db-89ef-8db7f5fcb2e4}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Deli; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {a9042189-0934-4921-90cb-c9afb666da7b}, !- Handle @@ -2078,7 +2078,7 @@ OS:SpaceType, {3fd7f60b-3ccb-41e9-9060-c4037f8c5f99}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Bakery; !- Standards Space Type + food preparation; !- Standards Space Type OS:Rendering:Color, {367065fb-924a-430d-a63d-7e3f0a5eb592}, !- Handle @@ -2095,7 +2095,7 @@ OS:SpaceType, {84362cb1-33b5-40b1-a2d9-2703bd689c96}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {e70e0639-d8d4-4133-98da-44f850867be3}, !- Handle @@ -2112,7 +2112,7 @@ OS:SpaceType, {56e5e7ff-0674-4534-843c-922f050bc52d}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Meeting; !- Standards Space Type + conference/meeting/multipurpose; !- Standards Space Type OS:Rendering:Color, {5fafb310-7e4d-4286-9d88-cdea90ef634b}, !- Handle @@ -2129,7 +2129,7 @@ OS:SpaceType, {b83e4b82-c5dc-421b-91d9-914e46793fc4}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Dining; !- Standards Space Type + dining; !- Standards Space Type OS:Rendering:Color, {0f4147c6-ed90-44e8-8d5e-91e4623ca5ee}, !- Handle @@ -2146,7 +2146,7 @@ OS:SpaceType, {704b3fcf-2856-4ed1-9db6-679aae8ce02e}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Restroom; !- Standards Space Type + restroom; !- Standards Space Type OS:Rendering:Color, {39ca94d3-8ecc-4d0c-9f9d-527e72ad1f56}, !- Handle @@ -2163,7 +2163,7 @@ OS:SpaceType, {ef6da368-3d45-4fbb-aea3-44e65e161773}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Elec/MechRoom; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {3355683a-baf8-41e8-bf16-16e57def1fb4}, !- Handle @@ -2180,7 +2180,7 @@ OS:SpaceType, {e929e980-8d62-4a6f-90ff-c2aff3c89dfc}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Corridor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {fc78297d-857b-4de7-98fe-949d2cecc4b3}, !- Handle @@ -2197,7 +2197,7 @@ OS:SpaceType, {122525b6-6325-4b96-90a2-f916ee284ba1}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - Vestibule; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {56d89051-dd95-408e-8e83-2729dc3e14e7}, !- Handle @@ -2214,7 +2214,7 @@ OS:SpaceType, {4eeb8088-1858-4a87-bffe-930a4088ba20}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SuperMarket, !- Standards Building Type - DryStorage; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {08a9d0dd-c052-4893-a56a-b95ee0e4c5f6}, !- Handle diff --git a/data/geometry/ASHRAESuperTallBuildingbase.osm b/data/geometry/ASHRAESuperTallBuildingbase.osm index c12dd42bd3..698834a79a 100644 --- a/data/geometry/ASHRAESuperTallBuildingbase.osm +++ b/data/geometry/ASHRAESuperTallBuildingbase.osm @@ -59182,7 +59182,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - BreakRoom; !- Standards Space Type + lounge/breakroom; !- Standards Space Type OS:Rendering:Color, {a310161c-afb7-4ae6-af42-df77d6142be8}, !- Handle @@ -59200,7 +59200,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Classroom; !- Standards Space Type + classroom/lecture/training; !- Standards Space Type OS:Rendering:Color, {954f00ea-e798-4829-bdfd-1c6ee8594bbe}, !- Handle @@ -59218,7 +59218,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - ClosedOffice; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {ece73a59-cb9a-461f-9c9b-efa18622390a}, !- Handle @@ -59236,7 +59236,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Conference; !- Standards Space Type + conference/meeting/multipurpose; !- Standards Space Type OS:Rendering:Color, {2d92e2dd-5df9-407c-8ff2-023df2759864}, !- Handle @@ -59254,7 +59254,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Corridor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {f46e0fd1-876d-4ab2-bf6f-92ac197dfce9}, !- Handle @@ -59272,7 +59272,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Dining; !- Standards Space Type + dining; !- Standards Space Type OS:Rendering:Color, {7b29fc2b-362d-4d42-a2ae-c4931be8210d}, !- Handle @@ -59290,7 +59290,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Elec/MechRoom; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {6253c024-de62-4d85-885a-df13656bcd5e}, !- Handle @@ -59308,7 +59308,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template HighriseApartment, !- Standards Building Type - Apartment; !- Standards Space Type + multifamily; !- Standards Space Type OS:Rendering:Color, {2490811d-cca4-48f7-9178-d108a2690123}, !- Handle @@ -59326,7 +59326,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template HighriseApartment, !- Standards Building Type - Apartment_topfloor_NS; !- Standards Space Type + multifamily; !- Standards Space Type OS:Rendering:Color, {e170da25-796a-47ac-a7e9-7293807260ca}, !- Handle @@ -59344,7 +59344,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template HighriseApartment, !- Standards Building Type - Apartment_topfloor_WE; !- Standards Space Type + multifamily; !- Standards Space Type OS:Rendering:Color, {60c4d153-050a-44ee-b26c-9cdca79b6583}, !- Handle @@ -59362,7 +59362,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template HighriseApartment, !- Standards Building Type - Corridor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {8437d558-9fda-4eb1-8490-b0f866ebff11}, !- Handle @@ -59380,7 +59380,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template HighriseApartment, !- Standards Building Type - Corridor_topfloor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {2d910251-cbb7-4dab-90ef-66ebf5eeba8e}, !- Handle @@ -59398,7 +59398,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template HighriseApartment, !- Standards Building Type - Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {3c3079d1-1c1d-43b6-a189-a1b575821be9}, !- Handle @@ -59416,7 +59416,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - Banquet; !- Standards Space Type + dining; !- Standards Space Type OS:Rendering:Color, {e3906e10-a054-407e-82a8-28ba39df572b}, !- Handle @@ -59434,7 +59434,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - Basement; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {98192a20-3bb0-43c7-8c73-59f862724b0b}, !- Handle @@ -59452,7 +59452,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - Cafe; !- Standards Space Type + dining; !- Standards Space Type OS:Rendering:Color, {8c74985b-2fac-465c-9d77-c26302e59653}, !- Handle @@ -59470,7 +59470,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - Corridor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {569f7a9c-a956-402a-a48c-ac97630da16a}, !- Handle @@ -59488,7 +59488,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - Corridor2; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {789ce74c-538b-4efa-a17c-0bd1626fa983}, !- Handle @@ -59506,7 +59506,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - GuestRoom; !- Standards Space Type + guest room; !- Standards Space Type OS:Rendering:Color, {a794066e-1ac3-4494-b9bc-de53ce5b434c}, !- Handle @@ -59524,7 +59524,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - GuestRoom2; !- Standards Space Type + guest room; !- Standards Space Type OS:Rendering:Color, {b3459ab9-6226-4751-b7c4-b67f5733bf11}, !- Handle @@ -59542,7 +59542,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - GuestRoom3; !- Standards Space Type + guest room; !- Standards Space Type OS:Rendering:Color, {d057d35a-e8b4-4268-bd39-9ef10485eb89}, !- Handle @@ -59560,7 +59560,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - GuestRoom4; !- Standards Space Type + guest room; !- Standards Space Type OS:Rendering:Color, {599d8962-90dd-42e4-81a7-b968368b4b1a}, !- Handle @@ -59578,7 +59578,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - Kitchen; !- Standards Space Type + food preparation; !- Standards Space Type OS:Rendering:Color, {d5bc2d65-7df3-4899-aca3-f2dd80282fde}, !- Handle @@ -59596,7 +59596,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - Laundry; !- Standards Space Type + laundry/washing; !- Standards Space Type OS:Rendering:Color, {18f0100f-8d2e-4cf1-a32c-ff29f983f331}, !- Handle @@ -59614,7 +59614,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - Lobby; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {a9529fed-c391-4a1a-9eb2-6cb4f4a78138}, !- Handle @@ -59632,7 +59632,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - Mechanical; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {4d9f4950-edb7-4553-af81-843da011004f}, !- Handle @@ -59650,7 +59650,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - Retail; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {b0cca15a-f193-4226-8ad8-40e1cacad3e7}, !- Handle @@ -59668,7 +59668,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - Retail2; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {e4c3f610-13ce-4cfe-bf6e-b7d8c641d1de}, !- Handle @@ -59686,7 +59686,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - Storage; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {91730480-679e-4f9b-aa22-556fe5cda447}, !- Handle @@ -59704,7 +59704,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Lobby; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {3d2a32f0-55ff-4d45-b619-6be24d5bfdf2}, !- Handle @@ -59722,7 +59722,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - OfficeLarge Data Center; !- Standards Space Type + datacenter/low ite; !- Standards Space Type OS:Rendering:Color, {ea2720b6-8471-43ae-a250-7d0d18ab456a}, !- Handle @@ -59740,7 +59740,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - OfficeLarge Main Data Center; !- Standards Space Type + datacenter/high ite; !- Standards Space Type OS:Rendering:Color, {a3acc8d2-c7db-42b5-a214-b9009514f972}, !- Handle @@ -59758,7 +59758,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - OpenOffice; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {2e9f25db-beb2-4182-9280-d80702ae33f1}, !- Handle @@ -59776,7 +59776,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Restroom; !- Standards Space Type + restroom; !- Standards Space Type OS:Rendering:Color, {ab627797-bdf6-4150-8dd4-ca2289590f1f}, !- Handle @@ -59794,7 +59794,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Retail, !- Standards Building Type - Back_Space; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {c458fa76-0fe6-4f38-aa34-5440f3e60472}, !- Handle @@ -59812,7 +59812,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Retail, !- Standards Building Type - Entry; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {85288b50-718f-4a25-aad7-e1a4a4e84bd1}, !- Handle @@ -59830,7 +59830,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Retail, !- Standards Building Type - Point_of_Sale; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {9dbf1a50-c4ca-4059-b99f-a442ac9ab439}, !- Handle @@ -59848,7 +59848,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Retail, !- Standards Building Type - Retail; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {b954611d-0bd5-4f2b-b4aa-2fa406f19cef}, !- Handle @@ -59866,7 +59866,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Stair; !- Standards Space Type + stairwell; !- Standards Space Type OS:Rendering:Color, {872f0ae1-5155-4ce4-aa13-5253a3ac310a}, !- Handle @@ -59885,7 +59885,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Storage; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {2faec3a2-1d42-427f-8860-e3371ede90c5}, !- Handle @@ -59903,7 +59903,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Elevator Lobby; !- Standards Space Type + lobby; !- Standards Space Type OS:SpaceType, {579e34d5-7bfd-4248-8f1d-33734e1a6006}, !- Handle @@ -59914,7 +59914,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Elevator Shaft; !- Standards Space Type + lobby; !- Standards Space Type OS:SpaceType, {44d06014-01c4-40f8-8a0c-c69856aa44b7}, !- Handle @@ -59925,7 +59925,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Elevator Machine Room; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:SpaceType, {c1a2dea1-5eea-416b-ab7e-54a1ac0bbcb2}, !- Handle @@ -59936,7 +59936,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Main Electrical; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:SpaceType, {ecb401c5-3574-4f75-8e32-1f7315c90162}, !- Handle @@ -59947,7 +59947,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Main Mechanical; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:SpaceType, {c94f2345-51cd-4ed2-a6bd-14651d7ec846}, !- Handle @@ -59958,7 +59958,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - GuestRoom5; !- Standards Space Type + guest room; !- Standards Space Type OS:SpaceType, {f835ed21-95fb-4162-9bd8-5361100ddccb}, !- Handle @@ -59969,7 +59969,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - GuestRoom6; !- Standards Space Type + guest room; !- Standards Space Type OS:SpaceType, {ba1f31d8-e76e-432b-a879-371d59a47197}, !- Handle @@ -59980,7 +59980,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - GuestRoom7; !- Standards Space Type + guest room; !- Standards Space Type OS:BuildingStory, {c03fa0e6-2b20-4f73-8d8c-efa9f7cbba53}, !- Handle diff --git a/data/geometry/ASHRAETallBuildingbase.osm b/data/geometry/ASHRAETallBuildingbase.osm index 7e4612d65c..48d4fa8ee8 100644 --- a/data/geometry/ASHRAETallBuildingbase.osm +++ b/data/geometry/ASHRAETallBuildingbase.osm @@ -53546,7 +53546,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - BreakRoom; !- Standards Space Type + lounge/breakroom; !- Standards Space Type OS:Rendering:Color, {a99fbfdd-6a6a-4cb9-a24f-ff27257f3a3b}, !- Handle @@ -53564,7 +53564,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Classroom; !- Standards Space Type + classroom/lecture/training; !- Standards Space Type OS:Rendering:Color, {f1eab6fb-aa05-4c20-9395-0bf12df146cf}, !- Handle @@ -53582,7 +53582,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - ClosedOffice; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {721ae511-bead-4e67-8004-7e3334db1dd4}, !- Handle @@ -53600,7 +53600,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Conference; !- Standards Space Type + conference/meeting/multipurpose; !- Standards Space Type OS:Rendering:Color, {02c4dbfa-74fb-4d4d-b5cf-c85588d7ad53}, !- Handle @@ -53618,7 +53618,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Corridor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {9805d1ae-1386-4e30-a44c-bdb043a89648}, !- Handle @@ -53636,7 +53636,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Dining; !- Standards Space Type + dining; !- Standards Space Type OS:Rendering:Color, {2186a831-c25c-4d41-9f41-a20aa1ffe4a2}, !- Handle @@ -53654,7 +53654,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Elec/MechRoom; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {aed30921-95d3-4cf4-8198-2924f8292104}, !- Handle @@ -53672,7 +53672,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template HighriseApartment, !- Standards Building Type - Apartment; !- Standards Space Type + multifamily; !- Standards Space Type OS:Rendering:Color, {3ecee402-6715-4f2a-847c-63bf638b72a3}, !- Handle @@ -53690,7 +53690,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template HighriseApartment, !- Standards Building Type - Apartment_topfloor_NS; !- Standards Space Type + multifamily; !- Standards Space Type OS:Rendering:Color, {69411813-fc1f-4c31-8b9b-680b77598148}, !- Handle @@ -53708,7 +53708,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template HighriseApartment, !- Standards Building Type - Apartment_topfloor_WE; !- Standards Space Type + multifamily; !- Standards Space Type OS:Rendering:Color, {66536b4a-3c8e-4bb4-a5f3-55d8b91b7a49}, !- Handle @@ -53726,7 +53726,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template HighriseApartment, !- Standards Building Type - Corridor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {f3bc2016-e866-485f-8706-be9ba1de2282}, !- Handle @@ -53744,7 +53744,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template HighriseApartment, !- Standards Building Type - Corridor_topfloor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {0a21be3d-7a35-49b0-a93d-5caa36faf7d2}, !- Handle @@ -53762,7 +53762,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template HighriseApartment, !- Standards Building Type - Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {168ea72d-afdd-4fee-b308-11e921238057}, !- Handle @@ -53780,7 +53780,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - Banquet; !- Standards Space Type + dining; !- Standards Space Type OS:Rendering:Color, {3bc8220e-b2a5-4a46-8548-923c31729f80}, !- Handle @@ -53798,7 +53798,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - Basement; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {1038c37d-83a1-4830-aa53-7f2a00779ec9}, !- Handle @@ -53816,7 +53816,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - Cafe; !- Standards Space Type + dining; !- Standards Space Type OS:Rendering:Color, {1315d0b3-7596-4000-a78c-7413534b5ca9}, !- Handle @@ -53834,7 +53834,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - Corridor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {35c7c7cd-87c7-4182-ae7d-c5f1ea40e082}, !- Handle @@ -53852,7 +53852,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - Corridor2; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {0e2cd06d-c4e7-45de-8e69-c609e8b6d948}, !- Handle @@ -53870,7 +53870,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - GuestRoom; !- Standards Space Type + guest room; !- Standards Space Type OS:Rendering:Color, {3a43ac69-07b5-471c-a6e1-4eddbeebeb49}, !- Handle @@ -53888,7 +53888,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - GuestRoom2; !- Standards Space Type + guest room; !- Standards Space Type OS:Rendering:Color, {769a71e1-10ad-480e-b496-2f2476cc14d6}, !- Handle @@ -53906,7 +53906,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - GuestRoom3; !- Standards Space Type + guest room; !- Standards Space Type OS:Rendering:Color, {25e39bbb-2a0c-41d3-84ac-80a22cd86c0b}, !- Handle @@ -53924,7 +53924,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - GuestRoom4; !- Standards Space Type + guest room; !- Standards Space Type OS:Rendering:Color, {a76c32e6-36e5-46a8-870b-2b3403339b4b}, !- Handle @@ -53942,7 +53942,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - Kitchen; !- Standards Space Type + food preparation; !- Standards Space Type OS:Rendering:Color, {cb97d509-e3b1-44ab-83b2-39eed93787a3}, !- Handle @@ -53960,7 +53960,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - Laundry; !- Standards Space Type + laundry/washing; !- Standards Space Type OS:Rendering:Color, {c010d79c-a7ac-405c-a300-979fe838255a}, !- Handle @@ -53978,7 +53978,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - Lobby; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {247a06a2-be2b-49a7-9bc2-b21fa590cf12}, !- Handle @@ -53996,7 +53996,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - Mechanical; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {543eae17-9690-4086-9888-bf8f2d595180}, !- Handle @@ -54014,7 +54014,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - Retail; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {872549cc-4b99-4ea6-9a4f-8c63f791dd92}, !- Handle @@ -54032,7 +54032,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - Retail2; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {2971b0b5-04b0-4856-9b0f-124855a7767a}, !- Handle @@ -54050,7 +54050,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - Storage; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {6727ccc7-9b68-44a3-ab41-93024d9d8f05}, !- Handle @@ -54068,7 +54068,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Lobby; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {5684d140-5496-4929-9e87-ab91443692e0}, !- Handle @@ -54086,7 +54086,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - OfficeLarge Data Center; !- Standards Space Type + datacenter/low ite; !- Standards Space Type OS:Rendering:Color, {2d5a9384-1064-4c3c-8ae0-07feaf150bbf}, !- Handle @@ -54104,7 +54104,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - OfficeLarge Main Data Center; !- Standards Space Type + datacenter/high ite; !- Standards Space Type OS:Rendering:Color, {1b972ab7-e3ff-48b5-a672-114babd55d3b}, !- Handle @@ -54122,7 +54122,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - OpenOffice; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {9d2bb677-f12d-4a27-a7f8-671c69b291cf}, !- Handle @@ -54140,7 +54140,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Restroom; !- Standards Space Type + restroom; !- Standards Space Type OS:Rendering:Color, {99cb542a-f008-415c-ad2d-3c818cc8db56}, !- Handle @@ -54158,7 +54158,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Retail, !- Standards Building Type - Back_Space; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {732b9c7e-256a-45b5-a319-96cc8df64ff5}, !- Handle @@ -54176,7 +54176,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Retail, !- Standards Building Type - Entry; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {c3043cfa-a430-45c5-8654-6b526cbb2572}, !- Handle @@ -54194,7 +54194,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Retail, !- Standards Building Type - Point_of_Sale; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {ebccfa9c-24ab-46aa-a119-14f592992abb}, !- Handle @@ -54212,7 +54212,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Retail, !- Standards Building Type - Retail; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {2c4c39dd-b88c-44b5-baa4-79165acd285b}, !- Handle @@ -54230,7 +54230,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Stair; !- Standards Space Type + stairwell; !- Standards Space Type OS:Rendering:Color, {690343ea-e8e7-4b88-9416-c727a8dc4788}, !- Handle @@ -54249,7 +54249,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Storage; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {ca9b786d-a652-4cd2-adf9-251fc6d36172}, !- Handle @@ -54267,7 +54267,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Elevator Lobby; !- Standards Space Type + lobby; !- Standards Space Type OS:SpaceType, {b2e624ed-a317-422f-ba4d-4962369d8dd3}, !- Handle @@ -54278,7 +54278,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Elevator Shaft; !- Standards Space Type + lobby; !- Standards Space Type OS:SpaceType, {e694b972-a4b9-4ab3-b6c1-18f9400b519b}, !- Handle @@ -54289,7 +54289,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Elevator Machine Room; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:SpaceType, {7e9b8a3b-4b69-4d4b-bf02-27411dba32d7}, !- Handle @@ -54300,7 +54300,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Main Electrical; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:SpaceType, {51f0eb91-cf0d-4fd2-a124-bc06023cb3c2}, !- Handle @@ -54311,7 +54311,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template Office, !- Standards Building Type - Main Mechanical; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:SpaceType, {3392663f-5b41-4f47-943b-1bdb7b548066}, !- Handle @@ -54322,7 +54322,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - GuestRoom5; !- Standards Space Type + guest room; !- Standards Space Type OS:SpaceType, {7229485b-f545-4a3f-a5ff-376f6c8edc53}, !- Handle @@ -54333,7 +54333,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - GuestRoom6; !- Standards Space Type + guest room; !- Standards Space Type OS:SpaceType, {aaa9dd7b-fcc7-42f6-a8c3-e75500577a25}, !- Handle @@ -54344,7 +54344,7 @@ OS:SpaceType, , !- Design Specification Outdoor Air Object Name , !- Standards Template LargeHotel, !- Standards Building Type - GuestRoom7; !- Standards Space Type + guest room; !- Standards Space Type OS:BuildingStory, {9ad0fb37-ca9c-4e39-a80d-14fc8f7086d1}, !- Handle diff --git a/data/geometry/CBESMediumOffice.osm b/data/geometry/CBESMediumOffice.osm index 1b6d2a3ee9..6fa8e18a2b 100644 --- a/data/geometry/CBESMediumOffice.osm +++ b/data/geometry/CBESMediumOffice.osm @@ -4452,7 +4452,7 @@ OS:SpaceType, {507a5052-c6fa-4e80-96ea-d8413460cc49}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Office, !- Standards Building Type - WholeBuilding - Md Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {507a5052-c6fa-4e80-96ea-d8413460cc49}, !- Handle diff --git a/data/geometry/CBESRetailStandalone.osm b/data/geometry/CBESRetailStandalone.osm index 98db1c2013..526f1e63f9 100644 --- a/data/geometry/CBESRetailStandalone.osm +++ b/data/geometry/CBESRetailStandalone.osm @@ -1366,7 +1366,7 @@ OS:SpaceType, {97b3f9f1-451c-4488-ad42-134d432a7e5b}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Retail, !- Standards Building Type - Back_Space; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {97b3f9f1-451c-4488-ad42-134d432a7e5b}, !- Handle @@ -1383,7 +1383,7 @@ OS:SpaceType, {d3080f5b-3a3e-4dc6-b8b0-2e0b97f50604}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Retail, !- Standards Building Type - Entry; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {d3080f5b-3a3e-4dc6-b8b0-2e0b97f50604}, !- Handle @@ -1400,7 +1400,7 @@ OS:SpaceType, {0a27121a-8997-40f0-835c-273c753446f7}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Retail, !- Standards Building Type - Point_of_Sale; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {0a27121a-8997-40f0-835c-273c753446f7}, !- Handle @@ -1417,7 +1417,7 @@ OS:SpaceType, {764e244f-b4b9-46b5-aa0f-cb5bf117a992}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Retail, !- Standards Building Type - Retail; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {764e244f-b4b9-46b5-aa0f-cb5bf117a992}, !- Handle diff --git a/data/geometry/CBESSmallOffice.osm b/data/geometry/CBESSmallOffice.osm index 2565a3106f..4e120468ca 100644 --- a/data/geometry/CBESSmallOffice.osm +++ b/data/geometry/CBESSmallOffice.osm @@ -1838,7 +1838,7 @@ OS:SpaceType, {507a5052-c6fa-4e80-96ea-d8413460cc49}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Office, !- Standards Building Type - WholeBuilding - Sm Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {507a5052-c6fa-4e80-96ea-d8413460cc49}, !- Handle @@ -1855,7 +1855,7 @@ OS:SpaceType, {de34b478-3803-4e06-a6b0-94fb668f99b0}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Office, !- Standards Building Type - Attic; !- Standards Space Type + attic; !- Standards Space Type OS:Rendering:Color, {de34b478-3803-4e06-a6b0-94fb668f99b0}, !- Handle diff --git a/data/geometry/DEER_Asm.osm b/data/geometry/DEER_Asm.osm index 5412643b68..33fd68aa57 100644 --- a/data/geometry/DEER_Asm.osm +++ b/data/geometry/DEER_Asm.osm @@ -1773,7 +1773,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Asm, !- Standards Building Type - Auditorium; !- Standards Space Type + audience seating; !- Standards Space Type OS:SpaceType, {7efdc289-8909-4807-aa4e-882f847dbf56}, !- Handle @@ -1783,7 +1783,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Asm, !- Standards Building Type - OfficeGeneral; !- Standards Space Type + office; !- Standards Space Type OS:ThermalZone, {5d89a67f-359c-4571-bb53-62ef5139e733}, !- Handle @@ -2613,5 +2613,5 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name , !- Standards Building Type - Plenum; !- Standards Space Type + plenum; !- Standards Space Type diff --git a/data/geometry/DEER_ECC.osm b/data/geometry/DEER_ECC.osm index 73f8a55e81..ee038d2a94 100644 --- a/data/geometry/DEER_ECC.osm +++ b/data/geometry/DEER_ECC.osm @@ -4480,7 +4480,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name ECC, !- Standards Building Type - Classroom; !- Standards Space Type + classroom/lecture/training; !- Standards Space Type OS:SpaceType, {d5e359bc-8c03-4b97-b9f5-07a4a83b7fea}, !- Handle @@ -4500,7 +4500,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name ECC, !- Standards Building Type - Dining; !- Standards Space Type + dining; !- Standards Space Type OS:SpaceType, {f6068a7c-4a5d-4520-82b5-fd8a5ecb7a9b}, !- Handle @@ -4510,7 +4510,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name ECC, !- Standards Building Type - Kitchen; !- Standards Space Type + food preparation; !- Standards Space Type OS:SpaceType, {7d775c0c-2a17-4d45-898a-caea84b8ea64}, !- Handle @@ -4520,7 +4520,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name ECC, !- Standards Building Type - OfficeGeneral; !- Standards Space Type + office; !- Standards Space Type OS:SpaceType, {de5a5701-469d-46dc-bf2e-6ade9f8b9b7c}, !- Handle @@ -7922,5 +7922,5 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name , !- Standards Building Type - Plenum; !- Standards Space Type + plenum; !- Standards Space Type diff --git a/data/geometry/DEER_EPr.osm b/data/geometry/DEER_EPr.osm index aac5ca5cf5..b55e947a55 100644 --- a/data/geometry/DEER_EPr.osm +++ b/data/geometry/DEER_EPr.osm @@ -1685,7 +1685,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name EPr, !- Standards Building Type - Classroom; !- Standards Space Type + classroom/lecture/training; !- Standards Space Type OS:SpaceType, {749a6bee-fa96-4dff-be22-8b4771f91e76}, !- Handle @@ -1695,7 +1695,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name EPr, !- Standards Building Type - Dining; !- Standards Space Type + dining; !- Standards Space Type OS:SpaceType, {82ee6f91-0f77-4eb2-9137-a499889deb58}, !- Handle @@ -1705,7 +1705,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name EPr, !- Standards Building Type - Gymnasium; !- Standards Space Type + exercise area; !- Standards Space Type OS:SpaceType, {3664932f-f79c-4d34-87e8-57b70e02fa35}, !- Handle @@ -1715,7 +1715,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name EPr, !- Standards Building Type - Kitchen; !- Standards Space Type + food preparation; !- Standards Space Type OS:ThermalZone, {2032f2dd-0f13-48c1-9cdc-26fb9698d9a5}, !- Handle @@ -2627,5 +2627,5 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name , !- Standards Building Type - Plenum; !- Standards Space Type + plenum; !- Standards Space Type diff --git a/data/geometry/DEER_ERC.osm b/data/geometry/DEER_ERC.osm index d92995f7ec..86ddada390 100644 --- a/data/geometry/DEER_ERC.osm +++ b/data/geometry/DEER_ERC.osm @@ -563,7 +563,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name ERC, !- Standards Building Type - Classroom; !- Standards Space Type + classroom/lecture/training; !- Standards Space Type OS:ThermalZone, {60fe5081-aa3e-4e3a-aa86-f726412c48b9}, !- Handle @@ -819,5 +819,5 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name , !- Standards Building Type - Plenum; !- Standards Space Type + plenum; !- Standards Space Type diff --git a/data/geometry/DEER_ESe.osm b/data/geometry/DEER_ESe.osm index 5962aecdce..710824ee7b 100644 --- a/data/geometry/DEER_ESe.osm +++ b/data/geometry/DEER_ESe.osm @@ -2742,7 +2742,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name ESe, !- Standards Building Type - Classroom; !- Standards Space Type + classroom/lecture/training; !- Standards Space Type OS:SpaceType, {29243df3-b501-44c7-8333-1fce59002668}, !- Handle @@ -2762,7 +2762,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name ESe, !- Standards Building Type - Dining; !- Standards Space Type + dining; !- Standards Space Type OS:SpaceType, {b3a2cf32-672a-4bcc-96fe-e640ec2fbb0c}, !- Handle @@ -2772,7 +2772,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name ESe, !- Standards Building Type - Gymnasium; !- Standards Space Type + exercise area; !- Standards Space Type OS:SpaceType, {52a7395f-7c11-4cf8-add8-30685f2fc6f0}, !- Handle @@ -2782,7 +2782,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name ESe, !- Standards Building Type - Kitchen; !- Standards Space Type + food preparation; !- Standards Space Type OS:ThermalZone, {c1ba5fba-5209-4c77-ab39-fdb73a839281}, !- Handle @@ -4596,7 +4596,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name , !- Standards Building Type - Plenum; !- Standards Space Type + plenum; !- Standards Space Type OS:Surface, {3c38cff1-f9bc-40bf-a64b-76ed9f08d5a3}, !- Handle diff --git a/data/geometry/DEER_EUn.osm b/data/geometry/DEER_EUn.osm index f6727ee7b3..d60940194d 100644 --- a/data/geometry/DEER_EUn.osm +++ b/data/geometry/DEER_EUn.osm @@ -7490,7 +7490,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name EUn, !- Standards Building Type - Classroom; !- Standards Space Type + classroom/lecture/training; !- Standards Space Type OS:SpaceType, {30170ce0-7a8a-49d4-a92c-d20369b09fef}, !- Handle @@ -7510,7 +7510,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name EUn, !- Standards Building Type - CorridorStairway; !- Standards Space Type + stairwell; !- Standards Space Type OS:SpaceType, {98c85a4e-8a54-414b-b506-c9d7507043d2}, !- Handle @@ -7520,7 +7520,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name EUn, !- Standards Building Type - Dining; !- Standards Space Type + dining; !- Standards Space Type OS:SpaceType, {d6ac571e-fa4d-48d6-a87d-866a666081f7}, !- Handle @@ -7540,7 +7540,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name EUn, !- Standards Building Type - Kitchen; !- Standards Space Type + food preparation; !- Standards Space Type OS:SpaceType, {06bf9451-c5aa-4155-8f50-cb58b16cab7c}, !- Handle @@ -7550,7 +7550,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name EUn, !- Standards Building Type - OfficeGeneral; !- Standards Space Type + office; !- Standards Space Type OS:SpaceType, {901d7b24-357d-423f-bb59-8f3b0a0d4507}, !- Handle @@ -12080,7 +12080,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name , !- Standards Building Type - Plenum; !- Standards Space Type + plenum; !- Standards Space Type OS:Surface, {08ce47da-92c2-4770-ab64-36241dcb4678}, !- Handle diff --git a/data/geometry/DEER_Gro.osm b/data/geometry/DEER_Gro.osm index 2592780723..e993e846ab 100644 --- a/data/geometry/DEER_Gro.osm +++ b/data/geometry/DEER_Gro.osm @@ -1311,7 +1311,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Gro, !- Standards Building Type - GrocSales; !- Standards Space Type + retail; !- Standards Space Type OS:SpaceType, {7db0a0bd-9aa4-45cd-9747-d2e0c17b7502}, !- Handle @@ -1321,7 +1321,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Gro, !- Standards Building Type - OfficeGeneral; !- Standards Space Type + office; !- Standards Space Type OS:SpaceType, {44a8edd8-c3fb-460d-8de4-7887fc170cae}, !- Handle diff --git a/data/geometry/DEER_Hsp.osm b/data/geometry/DEER_Hsp.osm index 235668fd80..5037923a25 100644 --- a/data/geometry/DEER_Hsp.osm +++ b/data/geometry/DEER_Hsp.osm @@ -6100,7 +6100,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hsp, !- Standards Building Type - Dining; !- Standards Space Type + dining; !- Standards Space Type OS:SpaceType, {67cdaa04-0ed8-45fc-9d5b-aede2c022071}, !- Handle @@ -6110,7 +6110,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hsp, !- Standards Building Type - HspSurgOutptLab; !- Standards Space Type + laboratory; !- Standards Space Type OS:SpaceType, {d3a57413-9b87-4ba2-bac9-69a2b24870a0}, !- Handle @@ -6120,7 +6120,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hsp, !- Standards Building Type - Kitchen; !- Standards Space Type + food preparation; !- Standards Space Type OS:SpaceType, {1333d8da-fb3b-450d-9a6a-ad18628ede63}, !- Handle @@ -6130,7 +6130,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Hsp, !- Standards Building Type - OfficeGeneral; !- Standards Space Type + office; !- Standards Space Type OS:SpaceType, {3e66655b-37dc-4d90-8ef3-e740531a40f8}, !- Handle @@ -10168,7 +10168,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name , !- Standards Building Type - Plenum; !- Standards Space Type + plenum; !- Standards Space Type OS:Surface, {cfa35c8e-ca3f-4bce-9353-45fd36cc990d}, !- Handle diff --git a/data/geometry/DEER_Htl.osm b/data/geometry/DEER_Htl.osm index 6c44ce7ba7..e128b1c9e0 100644 --- a/data/geometry/DEER_Htl.osm +++ b/data/geometry/DEER_Htl.osm @@ -8480,7 +8480,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Htl, !- Standards Building Type - Dining; !- Standards Space Type + dining; !- Standards Space Type OS:SpaceType, {556c6347-b7be-4a7a-bf80-da065b46a276}, !- Handle @@ -8510,7 +8510,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Htl, !- Standards Building Type - HotelLobby; !- Standards Space Type + lobby; !- Standards Space Type OS:SpaceType, {8ae54457-9b5a-4a33-baec-e1b5cb6be1d2}, !- Handle @@ -8520,7 +8520,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Htl, !- Standards Building Type - Kitchen; !- Standards Space Type + food preparation; !- Standards Space Type OS:SpaceType, {a7a55c46-7fa1-4f7f-9312-17cbc6a6fbc9}, !- Handle @@ -8530,7 +8530,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Htl, !- Standards Building Type - Laundry; !- Standards Space Type + laundry/washing; !- Standards Space Type OS:SpaceType, {7cd40050-b4be-4fea-a59e-0b26c9b32814}, !- Handle @@ -8540,7 +8540,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Htl, !- Standards Building Type - OfficeGeneral; !- Standards Space Type + office; !- Standards Space Type OS:ThermalZone, {ad360f49-bd6e-4b31-b97a-eeaaadd39dc1}, !- Handle @@ -12486,7 +12486,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name , !- Standards Building Type - Plenum; !- Standards Space Type + plenum; !- Standards Space Type OS:Surface, {0c966c7c-86db-4c05-baac-f645b184d925}, !- Handle diff --git a/data/geometry/DEER_MBT.osm b/data/geometry/DEER_MBT.osm index b285c36c04..07bb2be405 100644 --- a/data/geometry/DEER_MBT.osm +++ b/data/geometry/DEER_MBT.osm @@ -2978,7 +2978,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name MBT, !- Standards Building Type - Conference; !- Standards Space Type + conference/meeting/multipurpose; !- Standards Space Type OS:SpaceType, {7f93896f-4a7a-445f-a6c5-0efec97cfe2c}, !- Handle @@ -2988,7 +2988,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name MBT, !- Standards Building Type - CorridorStairway; !- Standards Space Type + stairwell; !- Standards Space Type OS:SpaceType, {c995cbb2-f342-4bfb-bc86-4b32307b3592}, !- Handle @@ -2998,7 +2998,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name MBT, !- Standards Building Type - Laboratory; !- Standards Space Type + laboratory; !- Standards Space Type OS:SpaceType, {8905b938-64e5-4658-8ce9-6a78f3092278}, !- Handle @@ -3008,7 +3008,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name MBT, !- Standards Building Type - OfficeOpen; !- Standards Space Type + office; !- Standards Space Type OS:SpaceType, {926df76e-5ffd-43ae-892b-f551ddbef75d}, !- Handle @@ -3018,7 +3018,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name MBT, !- Standards Building Type - Dining; !- Standards Space Type + dining; !- Standards Space Type OS:SpaceType, {90fe549d-fb78-4870-860e-a1358fb2c662}, !- Handle @@ -3028,7 +3028,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name MBT, !- Standards Building Type - Kitchen; !- Standards Space Type + food preparation; !- Standards Space Type OS:ThermalZone, {2e00aab7-823c-4dfe-be61-ffc7e68a9bab}, !- Handle @@ -4842,7 +4842,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name , !- Standards Building Type - Plenum; !- Standards Space Type + plenum; !- Standards Space Type OS:Surface, {333214f2-7420-4a46-be3a-c46c94702c03}, !- Handle diff --git a/data/geometry/DEER_MFm.osm b/data/geometry/DEER_MFm.osm index 5f70241a1f..96c4c3d19e 100644 --- a/data/geometry/DEER_MFm.osm +++ b/data/geometry/DEER_MFm.osm @@ -11974,5 +11974,5 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name , !- Standards Building Type - Plenum; !- Standards Space Type + plenum; !- Standards Space Type diff --git a/data/geometry/DEER_Mtl.osm b/data/geometry/DEER_Mtl.osm index 24894e0b8f..41fef5e8dd 100644 --- a/data/geometry/DEER_Mtl.osm +++ b/data/geometry/DEER_Mtl.osm @@ -5437,7 +5437,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Mtl, !- Standards Building Type - Laundry; !- Standards Space Type + laundry/washing; !- Standards Space Type OS:SpaceType, {a03333ef-47d7-4d91-ae4c-e6eac8d39a5b}, !- Handle @@ -5447,7 +5447,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Mtl, !- Standards Building Type - OfficeGeneral; !- Standards Space Type + office; !- Standards Space Type OS:ThermalZone, {cc477908-b3ba-4542-a123-f0bcc779d675}, !- Handle diff --git a/data/geometry/DEER_Nrs.osm b/data/geometry/DEER_Nrs.osm index 51a2de4e3d..ec2ba647a8 100644 --- a/data/geometry/DEER_Nrs.osm +++ b/data/geometry/DEER_Nrs.osm @@ -2647,7 +2647,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Nrs, !- Standards Building Type - CorridorStairway; !- Standards Space Type + stairwell; !- Standards Space Type OS:SpaceType, {b2fd4d32-8018-4b73-b37d-a5770d001747}, !- Handle @@ -2657,7 +2657,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Nrs, !- Standards Building Type - Dining; !- Standards Space Type + dining; !- Standards Space Type OS:SpaceType, {d9220f9a-2c5a-4206-a7bd-7f47ececad24}, !- Handle @@ -2667,7 +2667,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Nrs, !- Standards Building Type - Kitchen; !- Standards Space Type + food preparation; !- Standards Space Type OS:SpaceType, {baad95c2-2301-4259-9b5c-e7f74838202a}, !- Handle @@ -2677,7 +2677,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Nrs, !- Standards Building Type - OfficeGeneral; !- Standards Space Type + office; !- Standards Space Type OS:SpaceType, {57ce7636-4de7-459a-b96e-6fc5770be7b3}, !- Handle @@ -4337,7 +4337,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name , !- Standards Building Type - Plenum; !- Standards Space Type + plenum; !- Standards Space Type OS:Surface, {4300d593-52dc-4083-853c-957b6ba8a9d6}, !- Handle diff --git a/data/geometry/DEER_OfL.osm b/data/geometry/DEER_OfL.osm index a17ada5a0a..14df7220f4 100644 --- a/data/geometry/DEER_OfL.osm +++ b/data/geometry/DEER_OfL.osm @@ -3826,7 +3826,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name OfL, !- Standards Building Type - LobbyWaiting; !- Standards Space Type + lobby; !- Standards Space Type OS:SpaceType, {5ee851b4-f2ae-4075-a7e1-6fa593c0b3ba}, !- Handle @@ -3846,7 +3846,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name OfL, !- Standards Building Type - OfficeOpen; !- Standards Space Type + office; !- Standards Space Type OS:SpaceType, {f35b22f1-af66-4882-99e4-271aef07eaa2}, !- Handle @@ -3856,7 +3856,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name OfL, !- Standards Building Type - OfficeSmall; !- Standards Space Type + office; !- Standards Space Type OS:ThermalZone, {17dd05f8-8bf8-481c-9e27-6cc23e9e4f82}, !- Handle @@ -6326,5 +6326,5 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name , !- Standards Building Type - Plenum; !- Standards Space Type + plenum; !- Standards Space Type diff --git a/data/geometry/DEER_OfS.osm b/data/geometry/DEER_OfS.osm index cbf50e36ef..247da32d3a 100644 --- a/data/geometry/DEER_OfS.osm +++ b/data/geometry/DEER_OfS.osm @@ -2565,7 +2565,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name OfS, !- Standards Building Type - Hall; !- Standards Space Type + lobby; !- Standards Space Type OS:SpaceType, {032dd457-2f82-4a6c-a2aa-dfa0ab50ab5f}, !- Handle @@ -2575,7 +2575,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name OfS, !- Standards Building Type - OfficeSmall; !- Standards Space Type + office; !- Standards Space Type OS:ThermalZone, {7768453a-9003-4d27-a8e2-20e33cf43975}, !- Handle @@ -4225,5 +4225,5 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name , !- Standards Building Type - Plenum; !- Standards Space Type + plenum; !- Standards Space Type diff --git a/data/geometry/DEER_RFF.osm b/data/geometry/DEER_RFF.osm index 79d14c4731..0cf534c985 100644 --- a/data/geometry/DEER_RFF.osm +++ b/data/geometry/DEER_RFF.osm @@ -1270,7 +1270,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name RFF, !- Standards Building Type - Dining; !- Standards Space Type + dining; !- Standards Space Type OS:SpaceType, {13209b99-4226-4a26-8950-9d6f7039c223}, !- Handle @@ -1280,7 +1280,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name RFF, !- Standards Building Type - Kitchen; !- Standards Space Type + food preparation; !- Standards Space Type OS:SpaceType, {f750e5ca-117c-42fb-b229-4120e6ac488c}, !- Handle @@ -1290,7 +1290,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name RFF, !- Standards Building Type - LobbyWaiting; !- Standards Space Type + lobby; !- Standards Space Type OS:SpaceType, {e218e120-5b48-433e-9d16-8f40bfd4341a}, !- Handle @@ -1300,7 +1300,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name RFF, !- Standards Building Type - Restroom; !- Standards Space Type + restroom; !- Standards Space Type OS:ThermalZone, {a896f55e-fe40-427f-b3bc-32bcd0c468e4}, !- Handle @@ -1966,5 +1966,5 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name , !- Standards Building Type - Plenum; !- Standards Space Type + plenum; !- Standards Space Type diff --git a/data/geometry/DEER_RSD.osm b/data/geometry/DEER_RSD.osm index df07e666eb..a11f2f7ffe 100644 --- a/data/geometry/DEER_RSD.osm +++ b/data/geometry/DEER_RSD.osm @@ -1269,7 +1269,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name RSD, !- Standards Building Type - Dining; !- Standards Space Type + dining; !- Standards Space Type OS:SpaceType, {0ea74e37-eb42-439a-b930-ccdf2c2956f9}, !- Handle @@ -1279,7 +1279,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name RSD, !- Standards Building Type - LobbyWaiting; !- Standards Space Type + lobby; !- Standards Space Type OS:SpaceType, {6f22e2cb-6cd3-428a-8af0-096ead5c8f62}, !- Handle @@ -1289,7 +1289,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name RSD, !- Standards Building Type - Kitchen; !- Standards Space Type + food preparation; !- Standards Space Type OS:SpaceType, {bf4c0ae1-4801-49f0-96dd-39afecbd7a32}, !- Handle @@ -1299,7 +1299,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name RSD, !- Standards Building Type - Restroom; !- Standards Space Type + restroom; !- Standards Space Type OS:ThermalZone, {30a91bb7-3e43-4b2f-ae67-c4228edfd6e2}, !- Handle @@ -1965,5 +1965,5 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name , !- Standards Building Type - Plenum; !- Standards Space Type + plenum; !- Standards Space Type diff --git a/data/geometry/DEER_Rt3.osm b/data/geometry/DEER_Rt3.osm index f9a1a50b60..15bfe0546c 100644 --- a/data/geometry/DEER_Rt3.osm +++ b/data/geometry/DEER_Rt3.osm @@ -3797,7 +3797,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Rt3, !- Standards Building Type - RetailSales; !- Standards Space Type + retail; !- Standards Space Type OS:ThermalZone, {d07384aa-7bbb-466c-a025-a04af55fe006}, !- Handle @@ -6267,5 +6267,5 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name , !- Standards Building Type - Plenum; !- Standards Space Type + plenum; !- Standards Space Type diff --git a/data/geometry/DEER_RtL.osm b/data/geometry/DEER_RtL.osm index b2e1f5ae9c..6593d6645c 100644 --- a/data/geometry/DEER_RtL.osm +++ b/data/geometry/DEER_RtL.osm @@ -1376,7 +1376,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name RtL, !- Standards Building Type - OfficeGeneral; !- Standards Space Type + office; !- Standards Space Type OS:SpaceType, {321df5cb-26ab-4daf-80a2-93a8df1d727b}, !- Handle @@ -1406,7 +1406,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name RtL, !- Standards Building Type - RetailSales; !- Standards Space Type + retail; !- Standards Space Type OS:SpaceType, {ed250944-b7bf-4150-9635-a53bd0b94ac9}, !- Handle @@ -1416,7 +1416,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name RtL, !- Standards Building Type - Kitchen; !- Standards Space Type + food preparation; !- Standards Space Type OS:ThermalZone, {f689a3a4-0d49-4b78-bb77-49e08a8e27e8}, !- Handle diff --git a/data/geometry/DEER_RtS.osm b/data/geometry/DEER_RtS.osm index c2b0acfcf6..8097052bc3 100644 --- a/data/geometry/DEER_RtS.osm +++ b/data/geometry/DEER_RtS.osm @@ -870,7 +870,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name RtS, !- Standards Building Type - RetailSales; !- Standards Space Type + retail; !- Standards Space Type OS:SpaceType, {6d0a25b7-7aca-469d-9977-c6b57fcef994}, !- Handle @@ -1218,5 +1218,5 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name , !- Standards Building Type - Plenum; !- Standards Space Type + plenum; !- Standards Space Type diff --git a/data/geometry/DEER_WRf.osm b/data/geometry/DEER_WRf.osm index c897efbf19..10d4d3ca53 100644 --- a/data/geometry/DEER_WRf.osm +++ b/data/geometry/DEER_WRf.osm @@ -750,7 +750,7 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name WRf, !- Standards Building Type - OfficeGeneral; !- Standards Space Type + office; !- Standards Space Type OS:SpaceType, {c6da30eb-4ece-43eb-a308-b34123674df8}, !- Handle diff --git a/data/geometry/DOERefLargeHotel.osm b/data/geometry/DOERefLargeHotel.osm index d6b5b3c24f..442f83d400 100644 --- a/data/geometry/DOERefLargeHotel.osm +++ b/data/geometry/DOERefLargeHotel.osm @@ -6208,7 +6208,7 @@ OS:SpaceType, {50b38936-f4c4-4b15-9320-b8141f10ddb6}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - Banquet; !- Standards Space Type + dining; !- Standards Space Type OS:Rendering:Color, {50b38936-f4c4-4b15-9320-b8141f10ddb6}, !- Handle @@ -6225,7 +6225,7 @@ OS:SpaceType, {ad82c63e-7ff0-4e0e-9b38-9c1aa8df8180}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - Basement; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {ad82c63e-7ff0-4e0e-9b38-9c1aa8df8180}, !- Handle @@ -6242,7 +6242,7 @@ OS:SpaceType, {d9846bdc-761e-4b74-b47d-4d9099132c2d}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - Cafe; !- Standards Space Type + dining; !- Standards Space Type OS:Rendering:Color, {d9846bdc-761e-4b74-b47d-4d9099132c2d}, !- Handle @@ -6259,7 +6259,7 @@ OS:SpaceType, {3588649d-df17-4537-9d96-0bed9910e630}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - Corridor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {3588649d-df17-4537-9d96-0bed9910e630}, !- Handle @@ -6276,7 +6276,7 @@ OS:SpaceType, {5400f6e8-9423-4bcf-b3f0-8965dcf534d0}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - Corridor2; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {5400f6e8-9423-4bcf-b3f0-8965dcf534d0}, !- Handle @@ -6293,7 +6293,7 @@ OS:SpaceType, {e311b21f-427c-455e-b6f9-1a99271bf31b}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - GuestRoom; !- Standards Space Type + guest room; !- Standards Space Type OS:Rendering:Color, {e311b21f-427c-455e-b6f9-1a99271bf31b}, !- Handle @@ -6310,7 +6310,7 @@ OS:SpaceType, {df28cb16-bc1d-4ee9-b1b9-2df9ec5ddd20}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - GuestRoom2; !- Standards Space Type + guest room; !- Standards Space Type OS:Rendering:Color, {df28cb16-bc1d-4ee9-b1b9-2df9ec5ddd20}, !- Handle @@ -6327,7 +6327,7 @@ OS:SpaceType, {cc564a68-10f5-4448-9d40-a5ce68c77860}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - GuestRoom3; !- Standards Space Type + guest room; !- Standards Space Type OS:Rendering:Color, {cc564a68-10f5-4448-9d40-a5ce68c77860}, !- Handle @@ -6344,7 +6344,7 @@ OS:SpaceType, {db657990-5755-4ccd-924f-aeede9dcc85a}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - GuestRoom4; !- Standards Space Type + guest room; !- Standards Space Type OS:Rendering:Color, {db657990-5755-4ccd-924f-aeede9dcc85a}, !- Handle @@ -6361,7 +6361,7 @@ OS:SpaceType, {a6d4bd5f-7bbc-4f41-87f7-5d8f7fb109e3}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - Kitchen; !- Standards Space Type + food preparation; !- Standards Space Type OS:Rendering:Color, {a6d4bd5f-7bbc-4f41-87f7-5d8f7fb109e3}, !- Handle @@ -6378,7 +6378,7 @@ OS:SpaceType, {26b2859a-0872-4a25-a2e6-6dd7f963d667}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - Laundry; !- Standards Space Type + laundry/washing; !- Standards Space Type OS:Rendering:Color, {26b2859a-0872-4a25-a2e6-6dd7f963d667}, !- Handle @@ -6395,7 +6395,7 @@ OS:SpaceType, {3144ec28-2569-45d4-9647-95541e2088b1}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - Lobby; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {3144ec28-2569-45d4-9647-95541e2088b1}, !- Handle @@ -6412,7 +6412,7 @@ OS:SpaceType, {d9bea9b1-2936-4e5f-a153-398cf2edc31c}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - Mechanical; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {d9bea9b1-2936-4e5f-a153-398cf2edc31c}, !- Handle @@ -6429,7 +6429,7 @@ OS:SpaceType, {5adaf293-f8d2-4480-80be-792c2af092a6}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - Retail; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {5adaf293-f8d2-4480-80be-792c2af092a6}, !- Handle @@ -6446,7 +6446,7 @@ OS:SpaceType, {f118ef28-6a21-42dd-a9e5-44665a14c94a}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - Retail2; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {f118ef28-6a21-42dd-a9e5-44665a14c94a}, !- Handle @@ -6463,7 +6463,7 @@ OS:SpaceType, {13493879-6a84-4250-93da-925b138d817b}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name LargeHotel, !- Standards Building Type - Storage; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {13493879-6a84-4250-93da-925b138d817b}, !- Handle diff --git a/data/geometry/DOERefLargeOffice.osm b/data/geometry/DOERefLargeOffice.osm index 77b5376da8..94fdc98ccf 100644 --- a/data/geometry/DOERefLargeOffice.osm +++ b/data/geometry/DOERefLargeOffice.osm @@ -4484,7 +4484,7 @@ OS:SpaceType, {507a5052-c6fa-4e80-96ea-d8413460cc49}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Office, !- Standards Building Type - WholeBuilding - Lg Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {507a5052-c6fa-4e80-96ea-d8413460cc49}, !- Handle @@ -4501,4 +4501,4 @@ OS:SpaceType, , !- Group Rendering Name , !- Design Specification Outdoor Air Object Name , !- Standards Building Type - Plenum; !- Standards Space Type \ No newline at end of file + plenum; !- Standards Space Type diff --git a/data/geometry/DOERefMidriseApartment.osm b/data/geometry/DOERefMidriseApartment.osm index bf9ccee431..976b08dfc0 100644 --- a/data/geometry/DOERefMidriseApartment.osm +++ b/data/geometry/DOERefMidriseApartment.osm @@ -6416,7 +6416,7 @@ OS:SpaceType, {d5f1419a-2e63-460e-afcd-dfe102a5d5fb}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name MidriseApartment, !- Standards Building Type - Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {d5f1419a-2e63-460e-afcd-dfe102a5d5fb}, !- Handle @@ -6433,7 +6433,7 @@ OS:SpaceType, {e241c0d8-fa8f-499e-8a25-f4ea1cb20dcc}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name MidriseApartment, !- Standards Building Type - Corridor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {e241c0d8-fa8f-499e-8a25-f4ea1cb20dcc}, !- Handle @@ -6450,7 +6450,7 @@ OS:SpaceType, {2cb76859-269e-48d8-9938-995154c7a449}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name MidriseApartment, !- Standards Building Type - Apartment; !- Standards Space Type + multifamily; !- Standards Space Type OS:Rendering:Color, {2cb76859-269e-48d8-9938-995154c7a449}, !- Handle diff --git a/data/geometry/DOERefPre1980FullServiceRestaurant.osm b/data/geometry/DOERefPre1980FullServiceRestaurant.osm index 046df6ad43..a70f812fc6 100644 --- a/data/geometry/DOERefPre1980FullServiceRestaurant.osm +++ b/data/geometry/DOERefPre1980FullServiceRestaurant.osm @@ -664,7 +664,7 @@ OS:SpaceType, {507a5052-c6fa-4e80-96ea-d8413460cc49}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name FullServiceRestaurant, !- Standards Building Type - Dining; !- Standards Space Type + dining; !- Standards Space Type OS:Rendering:Color, {507a5052-c6fa-4e80-96ea-d8413460cc49}, !- Handle @@ -681,7 +681,7 @@ OS:SpaceType, {de34b478-3803-4e06-a6b0-94fb668f99b0}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name FullServiceRestaurant, !- Standards Building Type - Kitchen; !- Standards Space Type + food preparation; !- Standards Space Type OS:Rendering:Color, {de34b478-3803-4e06-a6b0-94fb668f99b0}, !- Handle diff --git a/data/geometry/DOERefPre1980QuickServiceRestaurant.osm b/data/geometry/DOERefPre1980QuickServiceRestaurant.osm index 381ed98b29..add8ee41ce 100644 --- a/data/geometry/DOERefPre1980QuickServiceRestaurant.osm +++ b/data/geometry/DOERefPre1980QuickServiceRestaurant.osm @@ -662,7 +662,7 @@ OS:SpaceType, {994c42ae-65a6-4582-836e-6df2b0f626ab}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name QuickServiceRestaurant, !- Standards Building Type - Dining; !- Standards Space Type + dining; !- Standards Space Type OS:Rendering:Color, {994c42ae-65a6-4582-836e-6df2b0f626ab}, !- Handle @@ -679,7 +679,7 @@ OS:SpaceType, {059a561a-51d8-4576-9a70-8a20249a6886}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name QuickServiceRestaurant, !- Standards Building Type - Kitchen; !- Standards Space Type + food preparation; !- Standards Space Type OS:Rendering:Color, {059a561a-51d8-4576-9a70-8a20249a6886}, !- Handle diff --git a/data/geometry/DOERefPre1980SmallOffice.osm b/data/geometry/DOERefPre1980SmallOffice.osm index f1d0368eae..5bb78fe18b 100644 --- a/data/geometry/DOERefPre1980SmallOffice.osm +++ b/data/geometry/DOERefPre1980SmallOffice.osm @@ -1602,7 +1602,7 @@ OS:SpaceType, {03bfd290-ffb6-4d2b-a0ab-77bbcba6bea4}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Office, !- Standards Building Type - WholeBuilding - Sm Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {03bfd290-ffb6-4d2b-a0ab-77bbcba6bea4}, !- Handle @@ -1619,7 +1619,7 @@ OS:SpaceType, {61f4697f-5695-4b1a-84f2-80b405c75f50}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Office, !- Standards Building Type - Attic; !- Standards Space Type + attic; !- Standards Space Type OS:Rendering:Color, {61f4697f-5695-4b1a-84f2-80b405c75f50}, !- Handle diff --git a/data/geometry/DOERefPrimarySchool.osm b/data/geometry/DOERefPrimarySchool.osm index 0523514898..d076e9467d 100644 --- a/data/geometry/DOERefPrimarySchool.osm +++ b/data/geometry/DOERefPrimarySchool.osm @@ -6311,7 +6311,7 @@ OS:SpaceType, {b5f3d145-0b77-4ecf-915c-f1c56739fe99}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name PrimarySchool, !- Standards Building Type - Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {b5f3d145-0b77-4ecf-915c-f1c56739fe99}, !- Handle @@ -6328,7 +6328,7 @@ OS:SpaceType, {66a356e0-b816-417d-8c80-c66e6f0e82f3}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name PrimarySchool, !- Standards Building Type - Lobby; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {66a356e0-b816-417d-8c80-c66e6f0e82f3}, !- Handle @@ -6345,7 +6345,7 @@ OS:SpaceType, {97fb5788-e23d-4898-97e2-784eae7f11b4}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name PrimarySchool, !- Standards Building Type - Gym; !- Standards Space Type + exercise area; !- Standards Space Type OS:Rendering:Color, {97fb5788-e23d-4898-97e2-784eae7f11b4}, !- Handle @@ -6362,7 +6362,7 @@ OS:SpaceType, {023bcd7f-a9b5-47c7-a888-761951c7579e}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name PrimarySchool, !- Standards Building Type - Mechanical; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {023bcd7f-a9b5-47c7-a888-761951c7579e}, !- Handle @@ -6379,7 +6379,7 @@ OS:SpaceType, {124b43d8-bb66-402a-9bf1-b919f8909174}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name PrimarySchool, !- Standards Building Type - Cafeteria; !- Standards Space Type + dining; !- Standards Space Type OS:Rendering:Color, {124b43d8-bb66-402a-9bf1-b919f8909174}, !- Handle @@ -6396,7 +6396,7 @@ OS:SpaceType, {8e034d0b-f6e0-4e3f-b0c8-e2ccdca43d18}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name PrimarySchool, !- Standards Building Type - Kitchen; !- Standards Space Type + food preparation; !- Standards Space Type OS:Rendering:Color, {8e034d0b-f6e0-4e3f-b0c8-e2ccdca43d18}, !- Handle @@ -6413,7 +6413,7 @@ OS:SpaceType, {b19b93f4-f5ba-40c2-b99d-cb0e9dfa18e6}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name PrimarySchool, !- Standards Building Type - Restroom; !- Standards Space Type + restroom; !- Standards Space Type OS:Rendering:Color, {b19b93f4-f5ba-40c2-b99d-cb0e9dfa18e6}, !- Handle @@ -6430,7 +6430,7 @@ OS:SpaceType, {2ff681c8-9964-4282-9ba4-cea87d7bcc42}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name PrimarySchool, !- Standards Building Type - Corridor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {2ff681c8-9964-4282-9ba4-cea87d7bcc42}, !- Handle @@ -6447,7 +6447,7 @@ OS:SpaceType, {57e34e90-72da-442f-8cbd-0a11214f9276}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name PrimarySchool, !- Standards Building Type - Classroom; !- Standards Space Type + classroom/lecture/training; !- Standards Space Type OS:Rendering:Color, {57e34e90-72da-442f-8cbd-0a11214f9276}, !- Handle diff --git a/data/geometry/DOERefRetailStandalone.osm b/data/geometry/DOERefRetailStandalone.osm index 537e16d78b..d997523159 100644 --- a/data/geometry/DOERefRetailStandalone.osm +++ b/data/geometry/DOERefRetailStandalone.osm @@ -1366,7 +1366,7 @@ OS:SpaceType, {97b3f9f1-451c-4488-ad42-134d432a7e5b}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Retail, !- Standards Building Type - Back_Space; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {97b3f9f1-451c-4488-ad42-134d432a7e5b}, !- Handle @@ -1383,7 +1383,7 @@ OS:SpaceType, {d3080f5b-3a3e-4dc6-b8b0-2e0b97f50604}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Retail, !- Standards Building Type - Entry; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {d3080f5b-3a3e-4dc6-b8b0-2e0b97f50604}, !- Handle @@ -1400,7 +1400,7 @@ OS:SpaceType, {0a27121a-8997-40f0-835c-273c753446f7}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Retail, !- Standards Building Type - Point_of_Sale; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {0a27121a-8997-40f0-835c-273c753446f7}, !- Handle @@ -1417,7 +1417,7 @@ OS:SpaceType, {764e244f-b4b9-46b5-aa0f-cb5bf117a992}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Retail, !- Standards Building Type - Retail; !- Standards Space Type + retail; !- Standards Space Type OS:Rendering:Color, {764e244f-b4b9-46b5-aa0f-cb5bf117a992}, !- Handle diff --git a/data/geometry/DOERefSecondarySchool.osm b/data/geometry/DOERefSecondarySchool.osm index c3adcdfd7e..8115469ea0 100644 --- a/data/geometry/DOERefSecondarySchool.osm +++ b/data/geometry/DOERefSecondarySchool.osm @@ -11738,7 +11738,7 @@ OS:SpaceType, {ae375c1a-a6f6-4f72-97c7-68988455a7f8}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SecondarySchool, !- Standards Building Type - Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {ae375c1a-a6f6-4f72-97c7-68988455a7f8}, !- Handle @@ -11755,7 +11755,7 @@ OS:SpaceType, {a6d15c65-3ddb-42e8-bd00-926e749c5bb2}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SecondarySchool, !- Standards Building Type - Lobby; !- Standards Space Type + lobby; !- Standards Space Type OS:Rendering:Color, {a6d15c65-3ddb-42e8-bd00-926e749c5bb2}, !- Handle @@ -11772,7 +11772,7 @@ OS:SpaceType, {d083477d-f5f6-4089-9cf1-32e6a9f6476f}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SecondarySchool, !- Standards Building Type - Gym; !- Standards Space Type + exercise area; !- Standards Space Type OS:Rendering:Color, {d083477d-f5f6-4089-9cf1-32e6a9f6476f}, !- Handle @@ -11789,7 +11789,7 @@ OS:SpaceType, {bbe5ef4c-9228-44af-b64a-afac7b888d58}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SecondarySchool, !- Standards Building Type - Gym - audience; !- Standards Space Type + exercise area; !- Standards Space Type OS:Rendering:Color, {bbe5ef4c-9228-44af-b64a-afac7b888d58}, !- Handle @@ -11806,7 +11806,7 @@ OS:SpaceType, {617a8237-69b6-4911-afc0-0416a9c98fb2}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SecondarySchool, !- Standards Building Type - Mechanical; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {617a8237-69b6-4911-afc0-0416a9c98fb2}, !- Handle @@ -11823,7 +11823,7 @@ OS:SpaceType, {c00a9beb-b35b-49fc-bcc6-a995e78f18ba}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SecondarySchool, !- Standards Building Type - Cafeteria; !- Standards Space Type + dining; !- Standards Space Type OS:Rendering:Color, {c00a9beb-b35b-49fc-bcc6-a995e78f18ba}, !- Handle @@ -11840,7 +11840,7 @@ OS:SpaceType, {0ee28c4d-2fff-48bf-89fd-8fbf762777b9}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SecondarySchool, !- Standards Building Type - Kitchen; !- Standards Space Type + food preparation; !- Standards Space Type OS:Rendering:Color, {0ee28c4d-2fff-48bf-89fd-8fbf762777b9}, !- Handle @@ -11857,7 +11857,7 @@ OS:SpaceType, {a85cd5d7-0061-4546-8ede-2b3366185288}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SecondarySchool, !- Standards Building Type - Restroom; !- Standards Space Type + restroom; !- Standards Space Type OS:Rendering:Color, {a85cd5d7-0061-4546-8ede-2b3366185288}, !- Handle @@ -11874,7 +11874,7 @@ OS:SpaceType, {8a4effad-3dbc-4f6d-a435-b77af1ceb8d8}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SecondarySchool, !- Standards Building Type - Auditorium; !- Standards Space Type + audience seating; !- Standards Space Type OS:Rendering:Color, {8a4effad-3dbc-4f6d-a435-b77af1ceb8d8}, !- Handle @@ -11891,7 +11891,7 @@ OS:SpaceType, {a33dce9a-85d0-4aab-b313-fb7d7bc37040}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SecondarySchool, !- Standards Building Type - Library; !- Standards Space Type + library; !- Standards Space Type OS:Rendering:Color, {a33dce9a-85d0-4aab-b313-fb7d7bc37040}, !- Handle @@ -11908,7 +11908,7 @@ OS:SpaceType, {42444a47-424d-4820-810f-d6393f429006}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SecondarySchool, !- Standards Building Type - Corridor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {42444a47-424d-4820-810f-d6393f429006}, !- Handle @@ -11925,7 +11925,7 @@ OS:SpaceType, {da98f479-caf2-452a-a12e-95330a652e3a}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SecondarySchool, !- Standards Building Type - Classroom; !- Standards Space Type + classroom/lecture/training; !- Standards Space Type OS:Rendering:Color, {da98f479-caf2-452a-a12e-95330a652e3a}, !- Handle diff --git a/data/geometry/DOERefSmallHotel.osm b/data/geometry/DOERefSmallHotel.osm index 30dc2f248a..81ffd03e07 100644 --- a/data/geometry/DOERefSmallHotel.osm +++ b/data/geometry/DOERefSmallHotel.osm @@ -17239,7 +17239,7 @@ OS:SpaceType, {507a5052-c6fa-4e80-96ea-d8413460cc49}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - Corridor; !- Standards Space Type + corridor; !- Standards Space Type OS:Rendering:Color, {507a5052-c6fa-4e80-96ea-d8413460cc49}, !- Handle @@ -17256,7 +17256,7 @@ OS:SpaceType, {de34b478-3803-4e06-a6b0-94fb668f99b0}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - Elec/MechRoom; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {de34b478-3803-4e06-a6b0-94fb668f99b0}, !- Handle @@ -17273,7 +17273,7 @@ OS:SpaceType, {3a0f162a-46fe-45d9-8a9b-011bcdf88e16}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - ElevatorCore; !- Standards Space Type + shaft; !- Standards Space Type OS:Rendering:Color, {3a0f162a-46fe-45d9-8a9b-011bcdf88e16}, !- Handle @@ -17290,7 +17290,7 @@ OS:SpaceType, {69c18cae-9d2f-4864-9c57-e3dd9c93faac}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - StaffLounge; !- Standards Space Type + lounge/breakroom; !- Standards Space Type OS:Rendering:Color, {69c18cae-9d2f-4864-9c57-e3dd9c93faac}, !- Handle @@ -17307,7 +17307,7 @@ OS:SpaceType, {13d8edca-f17b-4a9f-8402-de08ca4175c3}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - Exercise; !- Standards Space Type + exercise area; !- Standards Space Type OS:Rendering:Color, {13d8edca-f17b-4a9f-8402-de08ca4175c3}, !- Handle @@ -17324,7 +17324,7 @@ OS:SpaceType, {4b81ad58-3059-4888-a5f0-4667974bbc33}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - GuestLounge; !- Standards Space Type + lounge/breakroom; !- Standards Space Type OS:Rendering:Color, {4b81ad58-3059-4888-a5f0-4667974bbc33}, !- Handle @@ -17341,7 +17341,7 @@ OS:SpaceType, {5f90fb4b-00a3-4f7c-9da6-bb0d2f6c8dbd}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {5f90fb4b-00a3-4f7c-9da6-bb0d2f6c8dbd}, !- Handle @@ -17358,7 +17358,7 @@ OS:SpaceType, {35d16a43-528e-4bb0-b366-0307cf03d08b}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - Stair; !- Standards Space Type + stairwell; !- Standards Space Type OS:Rendering:Color, {35d16a43-528e-4bb0-b366-0307cf03d08b}, !- Handle @@ -17375,7 +17375,7 @@ OS:SpaceType, {b33dba6b-b3dc-431f-999e-546c9d49159b}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - Storage; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {b33dba6b-b3dc-431f-999e-546c9d49159b}, !- Handle @@ -17392,7 +17392,7 @@ OS:SpaceType, {ad242bae-a693-422e-8f2d-435218ff6c70}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - GuestRoom; !- Standards Space Type + guest room; !- Standards Space Type OS:Rendering:Color, {ad242bae-a693-422e-8f2d-435218ff6c70}, !- Handle @@ -17409,7 +17409,7 @@ OS:SpaceType, {d196909f-e708-424c-8b62-e23fef048807}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - Laundry; !- Standards Space Type + laundry/washing; !- Standards Space Type OS:Rendering:Color, {d196909f-e708-424c-8b62-e23fef048807}, !- Handle @@ -17426,7 +17426,7 @@ OS:SpaceType, {49de8715-0c8d-4155-8d49-022f93ad0fe6}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - Mechanical; !- Standards Space Type + electrical/mechanical; !- Standards Space Type OS:Rendering:Color, {49de8715-0c8d-4155-8d49-022f93ad0fe6}, !- Handle @@ -17443,7 +17443,7 @@ OS:SpaceType, {db9b36bb-e838-4180-8395-ff6c263593da}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - Meeting; !- Standards Space Type + conference/meeting/multipurpose; !- Standards Space Type OS:Rendering:Color, {db9b36bb-e838-4180-8395-ff6c263593da}, !- Handle @@ -17460,7 +17460,7 @@ OS:SpaceType, {ce525ba1-8b6c-4461-8bbc-16843874a57e}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - PublicRestroom; !- Standards Space Type + restroom; !- Standards Space Type OS:Rendering:Color, {ce525ba1-8b6c-4461-8bbc-16843874a57e}, !- Handle @@ -17477,7 +17477,7 @@ OS:SpaceType, {74928bcc-d6f5-4e09-ab22-149fe06810a7}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name SmallHotel, !- Standards Building Type - Attic; !- Standards Space Type + attic; !- Standards Space Type OS:Rendering:Color, {74928bcc-d6f5-4e09-ab22-149fe06810a7}, !- Handle diff --git a/data/geometry/DOERefWarehouse.osm b/data/geometry/DOERefWarehouse.osm index 042349beaf..a6f5413c43 100644 --- a/data/geometry/DOERefWarehouse.osm +++ b/data/geometry/DOERefWarehouse.osm @@ -1235,7 +1235,7 @@ OS:SpaceType, {507a5052-c6fa-4e80-96ea-d8413460cc49}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Warehouse, !- Standards Building Type - Bulk; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {507a5052-c6fa-4e80-96ea-d8413460cc49}, !- Handle @@ -1252,7 +1252,7 @@ OS:SpaceType, {de34b478-3803-4e06-a6b0-94fb668f99b0}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Warehouse, !- Standards Building Type - Fine; !- Standards Space Type + storage; !- Standards Space Type OS:Rendering:Color, {de34b478-3803-4e06-a6b0-94fb668f99b0}, !- Handle @@ -1269,7 +1269,7 @@ OS:SpaceType, {3a0f162a-46fe-45d9-8a9b-011bcdf88e16}, !- Group Rendering Name , !- Design Specification Outdoor Air Object Name Warehouse, !- Standards Building Type - Office; !- Standards Space Type + office; !- Standards Space Type OS:Rendering:Color, {3a0f162a-46fe-45d9-8a9b-011bcdf88e16}, !- Handle diff --git a/data/openstudio_standards_data/database_files/level_1_space_types.json b/data/openstudio_standards_data/database_files/level_1_space_types.json index 8abeab1094..9c07de1145 100644 --- a/data/openstudio_standards_data/database_files/level_1_space_types.json +++ b/data/openstudio_standards_data/database_files/level_1_space_types.json @@ -36,7 +36,7 @@ "annotation": null }, { - "space_type_name": "classroom, lecture, training", + "space_type_name": "classroom/lecture/training", "lighting_space_type_name": "classroom_lecture_training_lighting", "ventilation_space_type_name": "classroom_lecture_training_ventilation", "electric_equipment_space_type_name": "classroom_lecture_training_all_other_electric_equipment", @@ -54,7 +54,7 @@ "annotation": null }, { - "space_type_name": "conference, meeting, multipurpose", + "space_type_name": "conference/meeting/multipurpose", "lighting_space_type_name": "conference_meeting_multipurpose_lighting", "ventilation_space_type_name": "conference_meeting_multipurpose_ventilation", "electric_equipment_space_type_name": "conference_meeting_multipurpose_electric_equipment", @@ -72,7 +72,7 @@ "annotation": null }, { - "space_type_name": "copy, print", + "space_type_name": "copy/print", "lighting_space_type_name": "copy_print_lighting", "ventilation_space_type_name": "copy_print_ventilation", "electric_equipment_space_type_name": "office_enclosed_lte_250_sf_electric_equipment", @@ -99,7 +99,7 @@ "annotation": null }, { - "space_type_name": "datacenter, high ite", + "space_type_name": "datacenter/high ite", "lighting_space_type_name": "datacenterhighite_lighting", "ventilation_space_type_name": "datacenterhighite_ventilation", "electric_equipment_space_type_name": "datacenter_high_ite_equipment", @@ -108,7 +108,7 @@ "annotation": "to be revised" }, { - "space_type_name": "datacenter, low ite", + "space_type_name": "datacenter/low ite", "lighting_space_type_name": "datacenterlowite_lighting", "ventilation_space_type_name": "datacenterlowite_ventilation", "electric_equipment_space_type_name": "datacenter_low_ite_equipment", @@ -135,7 +135,7 @@ "annotation": null }, { - "space_type_name": "electrical, mechanical", + "space_type_name": "electrical/mechanical", "lighting_space_type_name": "electrical_mechanical_lighting", "ventilation_space_type_name": "electrical_mechanical_ventilation", "electric_equipment_space_type_name": "electrical_mechanical_electric_equipment", @@ -162,7 +162,7 @@ "annotation": null }, { - "space_type_name": "exam, treatment", + "space_type_name": "exam/treatment", "lighting_space_type_name": "exam_treatment_lighting", "ventilation_space_type_name": "exam_treatment_ventilation", "electric_equipment_space_type_name": "exam_treatment_electric_equipment", @@ -243,7 +243,7 @@ "annotation": null }, { - "space_type_name": "laundry, washing", + "space_type_name": "laundry/washing", "lighting_space_type_name": "laundry_washing_lighting", "ventilation_space_type_name": "laundry_washing_ventilation", "electric_equipment_space_type_name": "laundry_washing_electric_equipment", @@ -297,7 +297,7 @@ "annotation": null }, { - "space_type_name": "lounge, breakroom", + "space_type_name": "lounge/breakroom", "lighting_space_type_name": "lounge_breakroom_lighting", "ventilation_space_type_name": "lounge_breakroom_ventilation", "electric_equipment_space_type_name": "lounge_breakroom_all_other_electric_equipment", @@ -330,7 +330,7 @@ "electric_equipment_space_type_name": "multifamily_equipment", "natural_gas_equipment_space_type_name": null, "schedule_set_name": "lounge_breakroom_all_other", - "annotation": "common areas in a multifamily building, NOT dwelling units; schedule to be revised" + "annotation": "common areas in a multifamily building/NOT dwelling units; schedule to be revised" }, { "space_type_name": "nursery", @@ -360,7 +360,7 @@ "annotation": null }, { - "space_type_name": "office, enclosed", + "space_type_name": "office/enclosed", "lighting_space_type_name": "office_enclosed_lighting", "ventilation_space_type_name": "office_enclosed_ventilation", "electric_equipment_space_type_name": "office_enclosed_lte_250_sf_electric_equipment", @@ -441,7 +441,7 @@ "annotation": null }, { - "space_type_name": "recreation, common living", + "space_type_name": "recreation/common living", "lighting_space_type_name": "recreation_common_living_lighting", "ventilation_space_type_name": "recreation_common_living_ventilation", "electric_equipment_space_type_name": "lounge_breakroom_all_other_electric_equipment", From d4cb1b433979a772013b80e5d5b10f93db09261e Mon Sep 17 00:00:00 2001 From: Matthew Dahlhausen Date: Mon, 11 Sep 2023 22:03:57 -0600 Subject: [PATCH 34/45] add OsLib_Schedules methods move OsLib_Schedules methods from the openstudio-extension-gem to openstudio-standards. Add tests for the new methods. --- lib/openstudio-standards/schedules/create.rb | 365 ++++++++++++++ .../schedules/information.rb | 77 +++ lib/openstudio-standards/schedules/modify.rb | 447 ++++++++++++++++++ test/schedules/test_schedules_create.rb | 70 +++ test/schedules/test_schedules_information.rb | 36 ++ test/schedules/test_schedules_modify.rb | 70 +++ 6 files changed, 1065 insertions(+) create mode 100644 lib/openstudio-standards/schedules/create.rb create mode 100644 lib/openstudio-standards/schedules/information.rb create mode 100644 lib/openstudio-standards/schedules/modify.rb create mode 100644 test/schedules/test_schedules_create.rb create mode 100644 test/schedules/test_schedules_information.rb create mode 100644 test/schedules/test_schedules_modify.rb diff --git a/lib/openstudio-standards/schedules/create.rb b/lib/openstudio-standards/schedules/create.rb new file mode 100644 index 0000000000..a31051def4 --- /dev/null +++ b/lib/openstudio-standards/schedules/create.rb @@ -0,0 +1,365 @@ +# Methods to create Schedule objects +module OpenstudioStandards + module Schedules + module Create + # create a ruleset schedule with a basic profile + # + # @param model [OpenStudio::Model::Model] OpenStudio model object + # @param options [Hash] Hash of name and time value pairs + # @return [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object + def model_create_simple_schedule(model, options = {}) + defaults = { + 'name' => nil, + 'winterTimeValuePairs' => { 24.0 => 0.0 }, + 'summerTimeValuePairs' => { 24.0 => 1.0 }, + 'defaultTimeValuePairs' => { 24.0 => 1.0 } + } + + # merge user inputs with defaults + options = defaults.merge(options) + + # ScheduleRuleset + sch_ruleset = OpenStudio::Model::ScheduleRuleset.new(model) + if name + sch_ruleset.setName(options['name']) + end + + # Winter Design Day + winter_dsn_day = OpenStudio::Model::ScheduleDay.new(model) + sch_ruleset.setWinterDesignDaySchedule(winter_dsn_day) + winter_dsn_day = sch_ruleset.winterDesignDaySchedule + winter_dsn_day.setName("#{sch_ruleset.name} Winter Design Day") + options['winterTimeValuePairs'].each do |k, v| + hour = k.truncate + min = ((k - hour) * 60).to_i + winter_dsn_day.addValue(OpenStudio::Time.new(0, hour, min, 0), v) + end + + # Summer Design Day + summer_dsn_day = OpenStudio::Model::ScheduleDay.new(model) + sch_ruleset.setSummerDesignDaySchedule(summer_dsn_day) + summer_dsn_day = sch_ruleset.summerDesignDaySchedule + summer_dsn_day.setName("#{sch_ruleset.name} Summer Design Day") + options['summerTimeValuePairs'].each do |k, v| + hour = k.truncate + min = ((k - hour) * 60).to_i + summer_dsn_day.addValue(OpenStudio::Time.new(0, hour, min, 0), v) + end + + # All Days + default_day = sch_ruleset.defaultDaySchedule + default_day.setName("#{sch_ruleset.name} Schedule Week Day") + options['defaultTimeValuePairs'].each do |k, v| + hour = k.truncate + min = ((k - hour) * 60).to_i + default_day.addValue(OpenStudio::Time.new(0, hour, min, 0), v) + end + + return sch_ruleset + end + + # create a ruleset schedule with a complex profile + # + # @param model [OpenStudio::Model::Model] OpenStudio model object + # @param options [Hash] Hash of name and time value pairs + # @return [OpenStudio::Model::ScheduleRuleset] OpenStudio ruleset schedule object + def model_create_complex_schedule(model, options = {}) + defaults = { + 'name' => nil, + 'default_day' => ['always_on', [24.0, 1.0]] + } + + # merge user inputs with defaults + options = defaults.merge(options) + + # ScheduleRuleset + sch_ruleset = OpenStudio::Model::ScheduleRuleset.new(model) + if name + sch_ruleset.setName(options['name']) + end + + # Winter Design Day + unless options['winter_design_day'].nil? + winter_dsn_day = OpenStudio::Model::ScheduleDay.new(model) + sch_ruleset.setWinterDesignDaySchedule(winter_dsn_day) + winter_dsn_day = sch_ruleset.winterDesignDaySchedule + winter_dsn_day.setName("#{sch_ruleset.name} Winter Design Day") + options['winter_design_day'].each do |data_pair| + hour = data_pair[0].truncate + min = ((data_pair[0] - hour) * 60).to_i + winter_dsn_day.addValue(OpenStudio::Time.new(0, hour, min, 0), data_pair[1]) + end + end + + # Summer Design Day + unless options['summer_design_day'].nil? + summer_dsn_day = OpenStudio::Model::ScheduleDay.new(model) + sch_ruleset.setSummerDesignDaySchedule(summer_dsn_day) + summer_dsn_day = sch_ruleset.summerDesignDaySchedule + summer_dsn_day.setName("#{sch_ruleset.name} Summer Design Day") + options['summer_design_day'].each do |data_pair| + hour = data_pair[0].truncate + min = ((data_pair[0] - hour) * 60).to_i + summer_dsn_day.addValue(OpenStudio::Time.new(0, hour, min, 0), data_pair[1]) + end + end + + # Default Day + default_day = sch_ruleset.defaultDaySchedule + default_day.setName("#{sch_ruleset.name} #{options['default_day'][0]}") + default_data_array = options['default_day'] + default_data_array.delete_at(0) + default_data_array.each do |data_pair| + hour = data_pair[0].truncate + min = ((data_pair[0] - hour) * 60).to_i + default_day.addValue(OpenStudio::Time.new(0, hour, min, 0), data_pair[1]) + end + + # Rules + unless options['rules'].nil? + options['rules'].each do |data_array| + rule = OpenStudio::Model::ScheduleRule.new(sch_ruleset) + rule.setName("#{sch_ruleset.name} #{data_array[0]} Rule") + date_range = data_array[1].split('-') + start_date = date_range[0].split('/') + end_date = date_range[1].split('/') + rule.setStartDate(model.getYearDescription.makeDate(start_date[0].to_i, start_date[1].to_i)) + rule.setEndDate(model.getYearDescription.makeDate(end_date[0].to_i, end_date[1].to_i)) + days = data_array[2].split('/') + rule.setApplySunday(true) if days.include? 'Sun' + rule.setApplyMonday(true) if days.include? 'Mon' + rule.setApplyTuesday(true) if days.include? 'Tue' + rule.setApplyWednesday(true) if days.include? 'Wed' + rule.setApplyThursday(true) if days.include? 'Thu' + rule.setApplyFriday(true) if days.include? 'Fri' + rule.setApplySaturday(true) if days.include? 'Sat' + day_schedule = rule.daySchedule + day_schedule.setName("#{sch_ruleset.name} #{data_array[0]}") + data_array.delete_at(0) + data_array.delete_at(0) + data_array.delete_at(0) + data_array.each do |data_pair| + hour = data_pair[0].truncate + min = ((data_pair[0] - hour) * 60).to_i + day_schedule.addValue(OpenStudio::Time.new(0, hour, min, 0), data_pair[1]) + end + end + end + + return sch_ruleset + end + + # create a new schedule using absolute velocity of existing schedule + # + # @param model [OpenStudio::Model::Model] OpenStudio model object + # @param schedule [OpenStudio::Model::ScheduleRuleset] OpenStudio ruleset schedule object + # @return [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object + # @todo fix velocity so it isn't fraction change per step, but per hour + # (I need to count hours between times and divide value by this) + def model_create_schedule_from_rate_of_change(model, schedule_ruleset) + # clone source schedule + new_schedule = schedule_ruleset.clone(model) + new_schedule.setName("#{schedule_ruleset.name} - Rate of Change") + new_schedule = new_schedule.to_ScheduleRuleset.get + + # create array of all profiles to change. This includes summer, winter, default, and rules + profiles = [] + profiles << new_schedule.winterDesignDaySchedule + profiles << new_schedule.summerDesignDaySchedule + profiles << new_schedule.defaultDaySchedule + + # time values may need + end_profile_time = OpenStudio::Time.new(0, 24, 0, 0) + hour_bump_time = OpenStudio::Time.new(0, 1, 0, 0) + one_hour_left_time = OpenStudio::Time.new(0, 23, 0, 0) + + rules = new_schedule.scheduleRules + rules.each do |rule| + profiles << rule.daySchedule + end + + profiles.uniq.each do |profile| + times = profile.times + values = profile.values + + i = 0 + values_intermediate = [] + times_intermediate = [] + until i == values.size + if i == 0 + values_intermediate << 0.0 + if times[i] > hour_bump_time + times_intermediate << times[i] - hour_bump_time + if times[i + 1].nil? + time_step_value = end_profile_time.hours + end_profile_time.minutes / 60 - times[i].hours - times[i].minutes / 60 + else + time_step_value = times[i + 1].hours + times[i + 1].minutes / 60 - times[i].hours - times[i].minutes / 60 + end + values_intermediate << (values[i + 1].to_f - values[i].to_f).abs / (time_step_value * 2) + end + times_intermediate << times[i] + elsif i == (values.size - 1) + if times[times.size - 2] < one_hour_left_time + times_intermediate << times[times.size - 2] + hour_bump_time # this should be the second to last time + time_step_value = times[i - 1].hours + times[i - 1].minutes / 60 - times[i - 2].hours - times[i - 2].minutes / 60 + values_intermediate << (values[i - 1].to_f - values[i - 2].to_f).abs / (time_step_value * 2) + end + values_intermediate << 0.0 + times_intermediate << times[i] # this should be the last time + else + # get value multiplier based on how many hours it is spread over + time_step_value = times[i].hours + times[i].minutes / 60 - times[i - 1].hours - times[i - 1].minutes / 60 + values_intermediate << (values[i].to_f - values[i - 1].to_f).abs / time_step_value + times_intermediate << times[i] + end + i += 1 + end + + # delete all profile values + profile.clearValues + + i = 0 + until i == times_intermediate.size + if i == (times_intermediate.size - 1) + profile.addValue(times_intermediate[i], values_intermediate[i].to_f) + else + profile.addValue(times_intermediate[i], values_intermediate[i].to_f) + end + i += 1 + end + end + + return new_schedule + end + + # merge multiple schedules into one using load or other value to weight each schedules influence on the merge + # + # @param model [OpenStudio::Model::Model] OpenStudio model object + # @param schedule_weights_hash [Hash] Array of hashes of {OpenStudio::Model::ScheduleRuleset, Double} + # @sch_name [String] Optional name of new schedule + # @return [Hash] Hash of {OpenStudio::Model::ScheduleRuleset, Double} + # with the OpenStudio ScheduleRuleset object and the total denominator + # @todo apply weights to schedule rules as well, not just winter, summer, and default profile + def model_create_weighted_merge_schedules(model, schedule_weights_hash, sch_name: 'Merged Schedule') + # get denominator for weight + denominator = 0.0 + schedule_weights_hash.each do |schedule, weight| + denominator += weight + end + + # create new schedule + sch_ruleset = OpenStudio::Model::ScheduleRuleset.new(model) + sch_ruleset.setName(sch_name) + + # create winter design day profile + winter_dsn_day = OpenStudio::Model::ScheduleDay.new(model) + sch_ruleset.setWinterDesignDaySchedule(winter_dsn_day) + winter_dsn_day = sch_ruleset.winterDesignDaySchedule + winter_dsn_day.setName("#{sch_ruleset.name} Winter Design Day") + + # create summer design day profile + summer_dsn_day = OpenStudio::Model::ScheduleDay.new(model) + sch_ruleset.setSummerDesignDaySchedule(summer_dsn_day) + summer_dsn_day = sch_ruleset.summerDesignDaySchedule + summer_dsn_day.setName("#{sch_ruleset.name} Summer Design Day") + + # create default profile + default_day = sch_ruleset.defaultDaySchedule + default_day.setName("#{sch_ruleset.name} Schedule Week Day") + + # hash of schedule rules + rules_hash = {} # mon, tue, wed, thur, fri, sat, sun, startDate, endDate + # to avoid stacking order issues across schedules, I may need to make a rule for each day of the week for each date range + + schedule_weights_hash.each do |schedule, weight| + # populate winter design day profile + old_winter_profile = schedule.to_ScheduleRuleset.get.winterDesignDaySchedule + times_final = summer_dsn_day.times + i = 0 + value_updated_array = [] + # loop through times already in profile and update values + until i > times_final.size - 1 + value = old_winter_profile.getValue(times_final[i]) * weight / denominator + starting_value = winter_dsn_day.getValue(times_final[i]) + winter_dsn_day.addValue(times_final[i], value + starting_value) + value_updated_array << times_final[i] + i += 1 + end + # loop through any new times unique to the current old profile to be merged + j = 0 + times = old_winter_profile.times + values = old_winter_profile.values + until j > times.size - 1 + unless value_updated_array.include? times[j] + value = values[j] * weight / denominator + starting_value = winter_dsn_day.getValue(times[j]) + winter_dsn_day.addValue(times[j], value + starting_value) + end + j += 1 + end + + # populate summer design day profile + old_summer_profile = schedule.to_ScheduleRuleset.get.summerDesignDaySchedule + times_final = summer_dsn_day.times + i = 0 + value_updated_array = [] + # loop through times already in profile and update values + until i > times_final.size - 1 + value = old_summer_profile.getValue(times_final[i]) * weight / denominator + starting_value = summer_dsn_day.getValue(times_final[i]) + summer_dsn_day.addValue(times_final[i], value + starting_value) + value_updated_array << times_final[i] + i += 1 + end + # loop through any new times unique to the current old profile to be merged + j = 0 + times = old_summer_profile.times + values = old_summer_profile.values + until j > times.size - 1 + unless value_updated_array.include? times[j] + value = values[j] * weight / denominator + starting_value = summer_dsn_day.getValue(times[j]) + summer_dsn_day.addValue(times[j], value + starting_value) + end + j += 1 + end + + # populate default profile + old_default_profile = schedule.to_ScheduleRuleset.get.defaultDaySchedule + times_final = default_day.times + i = 0 + value_updated_array = [] + # loop through times already in profile and update values + until i > times_final.size - 1 + value = old_default_profile.getValue(times_final[i]) * weight / denominator + starting_value = default_day.getValue(times_final[i]) + default_day.addValue(times_final[i], value + starting_value) + value_updated_array << times_final[i] + i += 1 + end + # loop through any new times unique to the current old profile to be merged + j = 0 + times = old_default_profile.times + values = old_default_profile.values + until j > times.size - 1 + unless value_updated_array.include? times[j] + value = values[j] * weight / denominator + starting_value = default_day.getValue(times[j]) + default_day.addValue(times[j], value + starting_value) + end + j += 1 + end + + # create rules + + # gather data for rule profiles + + # populate rule profiles + end + + result = { 'mergedSchedule' => sch_ruleset, 'denominator' => denominator } + return result + end + end + end +end \ No newline at end of file diff --git a/lib/openstudio-standards/schedules/information.rb b/lib/openstudio-standards/schedules/information.rb new file mode 100644 index 0000000000..7e9fc9b84c --- /dev/null +++ b/lib/openstudio-standards/schedules/information.rb @@ -0,0 +1,77 @@ +# Methods to get information from Schedule objects +# Many of these methods may be moved to core OpenStudio +module OpenstudioStandards + module Schedules + module Information + + # add general schedule_min_max(schedule) method and merge with other methods + + # returns the schedule ruleset minimum and maximum values + # + # @param schedule_ruleset [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object + # @return [Hash] returns as hash with 'min' and 'max' values + def schedule_ruleset_min_max(schedule_ruleset) + # validate schedule + if schedule_ruleset.to_ScheduleRuleset.is_initialized + schedule = schedule_ruleset.to_ScheduleRuleset.get + + # gather profiles + profiles = [] + defaultProfile = schedule.defaultDaySchedule + profiles << defaultProfile + rules = schedule.scheduleRules + rules.each do |rule| + profiles << rule.daySchedule + end + + # test profiles + min = nil + max = nil + profiles.each do |profile| + profile.values.each do |value| + if min.nil? + min = value + else + if min > value then min = value end + end + if max.nil? + max = value + else + if max < value then max = value end + end + end + end + result = { 'min' => min, 'max' => max } # this doesn't include summer and winter design day + else + result = nil + end + + return result + end + + # create TimeSeries from ScheduleRuleset + # + # @param schedule_ruleset [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object + # @return [OpenStudio::TimeSeries] OpenStudio TimeSeries object of schedule values + def schedule_ruleset_timeseries(schedule_ruleset) + yd = schedule_ruleset.model.getYearDescription + start_date = yd.makeDate(1, 1) + end_date = yd.makeDate(12, 31) + + values = OpenStudio::DoubleVector.new + day = OpenStudio::Time.new(1.0) + interval = OpenStudio::Time.new(1.0 / 48.0) + day_schedules = schedule_ruleset.to_ScheduleRuleset.get.getDaySchedules(start_date, end_date) + day_schedules.each do |day_schedule| + time = interval + while time < day + values << day_schedule.getValue(time) + time += interval + end + end + timeseries = OpenStudio::TimeSeries.new(start_date, interval, OpenStudio.createVector(values), '') + return timeseries + end + end + end +end \ No newline at end of file diff --git a/lib/openstudio-standards/schedules/modify.rb b/lib/openstudio-standards/schedules/modify.rb new file mode 100644 index 0000000000..7dbd4d1c04 --- /dev/null +++ b/lib/openstudio-standards/schedules/modify.rb @@ -0,0 +1,447 @@ +# Methods to modify existing Schedule objects +module OpenstudioStandards + module Schedules + module Modify + + # Increase/decrease by percentage or static value + # + # @param schedule_ruleset [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object + # @param value [Double] Hash of name and time value pairs + # @param modification_type [String] Options are 'Multiplier', which multiples by the value, + # and 'Sum' which adds by the value + # @return [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object + # @todo add in design day adjustments, maybe as an optional argument + # @todo provide option to clone existing schedule + def schedule_ruleset_simple_value_adjust(schedule_ruleset, value, modification_type = 'Multiplier') + # gather profiles + profiles = [] + default_profile = schedule_ruleset.to_ScheduleRuleset.get.defaultDaySchedule + profiles << default_profile + rules = schedule_ruleset.scheduleRules + rules.each do |rule| + profiles << rule.daySchedule + end + + # alter profiles + profiles.each do |profile| + times = profile.times + i = 0 + profile.values.each do |sch_value| + case modification_type + when 'Multiplier', 'Percentage' + # percentage was used early on but Multiplier is preferable + profile.addValue(times[i], sch_value * value) + when 'Sum', 'Value' + # value was used early on but Sum is preferable + profile.addValue(times[i], sch_value + value) + end + i += 1 + end + end + + return schedule_ruleset + end + + # Increase/decrease by percentage or static value + # change value when value passes/fails test + # + # @param schedule_ruleset [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object + # @param test_value [Double] if less than the test_value, use the pass_value to modify, otherwise use the fail_value + # @param pass_value [Double] value to adjust by if less than test value + # @param fail_value [Double] value to adjust by if more than test value + # @param floor_value [Double] minimum value that the adjustment can take + # @param modification_type [String] Options are 'Multiplier', which multiples by the value, + # and 'Sum' which adds by the value + # @return [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object + # @todo add in design day adjustments, maybe as an optional argument + # @todo provide option to clone existing schedule + def schedule_ruleset_conditional_adjust_value(schedule_ruleset, test_value, pass_value, fail_value, floor_value, modification_type = 'Multiplier') + # gather profiles + profiles = [] + default_profile = schedule_ruleset.to_ScheduleRuleset.get.defaultDaySchedule + profiles << default_profile + rules = schedule_ruleset.scheduleRules + rules.each do |rule| + profiles << rule.daySchedule + end + + # alter profiles + profiles.each do |profile| + times = profile.times + i = 0 + + profile.values.each do |sch_value| + # run test on this sch_value + if sch_value < test_value + adjust_value = pass_value + else + adjust_value = fail_value + end + + # skip if sch_value is floor or less + next if sch_value <= floor_value + + case modification_type + when 'Multiplier' + # take the max of the floor or resulting value + profile.addValue(times[i], [sch_value * adjust_value, floor_value].max) + when 'Sum' + # take the max of the floor or resulting value + profile.addValue(times[i], [sch_value + adjust_value, floor_value].max) + end + i += 1 + end + end + + return schedule_ruleset + end + + # Increase/decrease by percentage or static value + # change value when time passes test + # + # @param schedule_ruleset [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object + # @param hhmm_before [String] time before string in hhmm format, e.g. 1530 + # @param hhmm_after [String] string in hhmm format, e.g. 1530 + # @param inside_value [Double] + # @param outside_value [Double] + # @param modification_type [String] Options are 'Sum', which adds to the value, + # and 'Replace' which replaces the value + # @return [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object + def schedule_ruleset_time_conditional_adjust_value(schedule_ruleset, hhmm_before, hhmm_after, inside_value, outside_value, modification_type = 'Sum') + # setup variables + array = hhmm_before.to_s.split('') + before_hour = "#{array[0]}#{array[1]}".to_i + before_min = "#{array[2]}#{array[3]}".to_i + array = hhmm_after.to_s.split('') + after_hour = "#{array[0]}#{array[1]}".to_i + after_min = "#{array[2]}#{array[3]}".to_i + + # gather profiles + profiles = [] + schedule = schedule_ruleset.to_ScheduleRuleset.get + default_profile = schedule_ruleset.defaultDaySchedule + profiles << default_profile + rules = schedule_ruleset.scheduleRules + rules.each do |rule| + profiles << rule.daySchedule + end + + # alter profiles + profiles.each do |day_sch| + times = day_sch.times + i = 0 + + # set times special times needed for methods below + before_time = OpenStudio::Time.new(0, before_hour, before_min, 0) + after_time = OpenStudio::Time.new(0, after_hour, after_min, 0) + # day_end_time = OpenStudio::Time.new(0, 24, 0, 0) + + # add datapoint at before and after time + original_value_at_before_time = day_sch.getValue(before_time) + original_value_at_after_time = day_sch.getValue(after_time) + day_sch.addValue(before_time, original_value_at_before_time) + day_sch.addValue(after_time, original_value_at_after_time) + + # make arrays for original times and values + times = day_sch.times + sch_values = day_sch.values + day_sch.clearValues + + # make arrays for new values + new_times = [] + new_values = [] + + # loop through original time/value pairs to populate new array + for i in 0..(sch_values.length - 1) + new_times << times[i] + + if times[i] > before_time && times[i] <= after_time + # updated this so times[i] == before_time goes into the else + if inside_value.nil? + new_values << sch_values[i] + elsif modification_type == 'Sum' + new_values << inside_value + sch_values[i] + elsif modification_type == 'Replace' + new_values << inside_value + else # should be Multiplier + new_values << inside_value * sch_values[i] + end + else + if outside_value.nil? + new_values << sch_values[i] + elsif modification_type == 'Sum' + new_values << outside_value + sch_values[i] + elsif modification_type == 'Replace' + new_values << outside_value + else # should be Multiplier + new_values << outside_value * sch_values[i] + end + end + + end + + # generate new day_sch values + for i in 0..(new_values.length - 1) + day_sch.addValue(new_times[i], new_values[i]) + end + end + + return schedule_ruleset + end + + # Adjust hours of operation + # + # @param schedule_ruleset [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object + # @param options [Hash] Hash of argument options + # @return [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object + def schedule_ruleset_adjust_hours_of_operation(schedule_ruleset, options = {}) + defaults = { + 'base_start_hoo' => 8.0, # may not be good idea to have default + 'base_finish_hoo' => 18.0, # may not be good idea to have default + 'delta_length_hoo' => 0.0, + 'shift_hoo' => 0.0, + 'default' => true, + 'mon' => true, + 'tue' => true, + 'wed' => true, + 'thur' => true, + 'fri' => true, + 'sat' => true, + 'sun' => true, + 'summer' => false, + 'winter' => false + } + + # merge user inputs with defaults + options = defaults.merge(options) + + # grab schedule out of argument + if schedule_ruleset.to_ScheduleRuleset.is_initialized + schedule = schedule_ruleset.to_ScheduleRuleset.get + else + OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.Schedules.Modify', "schedule_ruleset_adjust_hours_of_operation only applies to ScheduleRuleset objects. Skipping #{schedule.name}") + return nil + end + + # array of all profiles to change + profiles = [] + + # push default profiles to array + if options['default'] + default_rule = schedule.defaultDaySchedule + profiles << default_rule + end + + # push profiles to array + rules = schedule.scheduleRules + rules.each do |rule| + day_sch = rule.daySchedule + + # if any day requested also exists in the rule, then it will be altered + alter_rule = false + if rule.applyMonday && rule.applyMonday == options['mon'] then alter_rule = true end + if rule.applyTuesday && rule.applyTuesday == options['tue'] then alter_rule = true end + if rule.applyWednesday && rule.applyWednesday == options['wed'] then alter_rule = true end + if rule.applyThursday && rule.applyThursday == options['thur'] then alter_rule = true end + if rule.applyFriday && rule.applyFriday == options['fri'] then alter_rule = true end + if rule.applySaturday && rule.applySaturday == options['sat'] then alter_rule = true end + if rule.applySunday && rule.applySunday == options['sun'] then alter_rule = true end + + # TODO: - add in logic to warn user about conflicts where a single rule has conflicting tests + + if alter_rule + profiles << day_sch + end + end + + # add design days to array + if options['summer'] + summer_design = schedule.summerDesignDaySchedule + profiles << summer_design + end + if options['winter'] + winter_design = schedule.winterDesignDaySchedule + profiles << winter_design + end + + # give info messages as I change specific profiles + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.Schedules.Modify', "Adjusting #{schedule.name}") + + # rename schedule + schedule.setName("#{schedule.name} - extend #{options['delta_length_hoo']} shift #{options['shift_hoo']}") + + # break time args into hours and minutes + start_hoo_hours = (options['base_start_hoo']).to_i + start_hoo_minutes = (((options['base_start_hoo']) - (options['base_start_hoo']).to_i) * 60).to_i + finish_hoo_hours = (options['base_finish_hoo']).to_i + finish_hoo_minutes = (((options['base_finish_hoo']) - (options['base_finish_hoo']).to_i) * 60).to_i + delta_hours = (options['delta_length_hoo']).to_i + delta_minutes = (((options['delta_length_hoo']) - (options['delta_length_hoo']).to_i) * 60).to_i + shift_hours = (options['shift_hoo']).to_i + shift_minutes = (((options['shift_hoo']) - (options['shift_hoo']).to_i) * 60).to_i + + # time objects to use in measure + time_0 = OpenStudio::Time.new(0, 0, 0, 0) + time_1_min = OpenStudio::Time.new(0, 0, 1, 0) # add this to avoid times in day profile less than this + time_12 = OpenStudio::Time.new(0, 12, 0, 0) + time_24 = OpenStudio::Time.new(0, 24, 0, 0) + start_hoo_time = OpenStudio::Time.new(0, start_hoo_hours, start_hoo_minutes, 0) + finish_hoo_time = OpenStudio::Time.new(0, finish_hoo_hours, finish_hoo_minutes, 0) + delta_time = OpenStudio::Time.new(0, delta_hours, delta_minutes, 0) # not used + shift_time = OpenStudio::Time.new(0, shift_hours, shift_minutes, 0) + + # calculations + if options['base_start_hoo'] <= options['base_finish_hoo'] + base_opp_day_length = options['base_finish_hoo'] - options['base_start_hoo'] + mid_hoo = start_hoo_time + (finish_hoo_time - start_hoo_time) / 2 + mid_non_hoo = mid_hoo + time_12 + if mid_non_hoo > time_24 then mid_non_hoo -= time_24 end + else + base_opp_day_length = options['base_finish_hoo'] - options['base_start_hoo'] + 24 + mid_non_hoo = finish_hoo_time + (start_hoo_time - finish_hoo_time) / 2 + mid_hoo = mid_non_hoo + time_12 + if mid_non_hoo > time_24 then mid_non_hoo -= time_24 end + end + adjusted_opp_day_length = base_opp_day_length + options['delta_length_hoo'] + hoo_time_multiplier = adjusted_opp_day_length / base_opp_day_length + non_hoo_time_multiplier = (24 - adjusted_opp_day_length) / (24 - base_opp_day_length) + + # check for invalid input + if adjusted_opp_day_length < 0 + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.Schedules.Modify', 'Requested hours of operation adjustment results in an invalid negative hours of operation') + return false + end + # check for invalid input + if adjusted_opp_day_length > 24 + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.Schedules.Modify', 'Requested hours of operation adjustment results in more than 24 hours of operation') + return false + end + + # making some temp objects to avoid having to deal with wrap around for change of hoo times + mid_hoo < start_hoo_time ? (adj_mid_hoo = mid_hoo + time_24) : (adj_mid_hoo = mid_hoo) + finish_hoo_time < adj_mid_hoo ? (adj_finish_hoo_time = finish_hoo_time + time_24) : (adj_finish_hoo_time = finish_hoo_time) + mid_non_hoo < adj_finish_hoo_time ? (adj_mid_non_hoo = mid_non_hoo + time_24) : (adj_mid_non_hoo = mid_non_hoo) + adj_start = start_hoo_time + time_24 # not used + + # edit profiles + profiles.each do |day_sch| + times = day_sch.times + values = day_sch.values + + # in this case delete all values outside of + # todo - may need similar logic if exactly 0 hours + if adjusted_opp_day_length == 24 + start_val = day_sch.getValue(start_hoo_time) + finish_val = day_sch.getValue(finish_hoo_time) + + # remove times out of range that should not be reference or compressed + if start_hoo_time < finish_hoo_time + times.each do |time| + if time <= start_hoo_time || time > finish_hoo_time + day_sch.removeValue(time) + end + end + # add in values + day_sch.addValue(start_hoo_time,start_val) + day_sch.addValue(finish_hoo_time,finish_val) + day_sch.addValue(time_24,[start_val,finish_val].max) + else + times.each do |time| + if time > start_hoo_time && time <= finish_hoo_time + day_sch.removeValue(time) + end + end + # add in values + day_sch.addValue(finish_hoo_time,finish_val) + day_sch.addValue(start_hoo_time,start_val) + day_sch.addValue(time_24,[values.first,values.last].max) + end + + end + + times = day_sch.times + values = day_sch.values + + # arrays for values to avoid overlap conflict of times + new_times = [] + new_values = [] + + # this is to store what datapoint will be first after midnight, and what the value at that time should be + min_time_new = time_24 + min_time_value = nil + + # flag if found time at 24 + found_24_or_0 = false + + # push times to array + times.each do |time| + # create logic for four possible quadrants. Assume any quadrant can pass over 24/0 threshold + time < start_hoo_time ? (temp_time = time + time_24) : (temp_time = time) + + # calculate change in time do to hoo delta + if temp_time <= adj_finish_hoo_time + expand_time = (temp_time - adj_mid_hoo) * hoo_time_multiplier - (temp_time - adj_mid_hoo) + else + expand_time = (temp_time - adj_mid_non_hoo) * non_hoo_time_multiplier - (temp_time - adj_mid_non_hoo) + end + + new_time = time + shift_time + expand_time + + # adjust wrap around times + if new_time < time_0 + new_time += time_24 + elsif new_time > time_24 + new_time -= time_24 + end + new_times << new_time + + # see which new_time has the lowest value. Then add a value at 24 equal to that + if !found_24_or_0 && new_time <= min_time_new + min_time_new = new_time + min_time_value = day_sch.getValue(time) + elsif new_time == time_24 # this was added to address time exactly at 24 + min_time_new = new_time + min_time_value = day_sch.getValue(time) + found_24_or_0 = true + elsif new_time == time_0 + min_time_new = new_time + min_time_value = day_sch.getValue(time_0) + found_24_or_0 = true + end + end + + # push values to array + values.each do |value| + new_values << value + end + + # add value for what will be 24 + new_times << time_24 + new_values << min_time_value + + new_time_val_hash = {} + new_times.each_with_index do |time,i| + new_time_val_hash[time.totalHours] = {:time => time, :value => new_values[i]} + end + + # clear values + day_sch.clearValues + + new_time_val_hash = Hash[new_time_val_hash.sort] + prev_time = nil + new_time_val_hash.sort.each do |hours,time_val| + if prev_time.nil? || time_val[:time] - prev_time > time_1_min + day_sch.addValue(time_val[:time], time_val[:value]) + prev_time = time_val[:time] + else + OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.Schedules.Modify', "Time step in #{day_sch.name} between #{prev_time.toString} and #{time_val[:time].toString} is too small to support, not adding value.") + end + end + + end + + return schedule + end + end + end +end \ No newline at end of file diff --git a/test/schedules/test_schedules_create.rb b/test/schedules/test_schedules_create.rb new file mode 100644 index 0000000000..dccfecff80 --- /dev/null +++ b/test/schedules/test_schedules_create.rb @@ -0,0 +1,70 @@ +require_relative '../helpers/minitest_helper' +require_relative '../../lib/openstudio-standards/schedules/create' + +class TestSchedulesCreate < Minitest::Test + include OpenstudioStandards::Schedules::Create + + def test_model_create_simple_schedule + model = OpenStudio::Model::Model.new + test_options = { + 'name' => 'Test Create Simple', + 'winterTimeValuePairs' => { 8.0 => 0.0, 16.0 => 1.0, 24.0 => 0.0 }, + 'summerTimeValuePairs' => { 8.0 => 0.0, 16.0 => 1.0, 24.0 => 0.0 }, + 'defaultTimeValuePairs' => { 8.0 => 0.0, 16.0 => 1.0, 24.0 => 0.0 } + } + schedule = model_create_simple_schedule(model, test_options) + assert(schedule.to_ScheduleRuleset.is_initialized) + assert(schedule.name.to_s == 'Test Create Simple') + end + + def test_model_create_complex_schedule + model = OpenStudio::Model::Model.new + rules = [] + rules << ['Tuesdays and Thursdays', '1/1-12/31', 'Tue/Thu', [4, 0], [4.33, 1], [18, 0], [18.66, 1], [24, 0]] + test_options = { + 'name' => 'Test Create Complex', + 'winter_design_day' => [[24, 0]], + 'summer_design_day' => [[24, 1]], + 'default_day' => ['Test Create Complex Default', [11, 0], [11.33, 1], [23, 0], [23.33, 1], [24, 0]], + 'rules' => rules + } + schedule = model_create_complex_schedule(model, test_options) + assert(schedule.to_ScheduleRuleset.is_initialized) + assert(schedule.name.to_s == 'Test Create Complex') + end + + def test_model_create_schedule_from_rate_of_change + model = OpenStudio::Model::Model.new + test_options = { + 'name' => 'Test Create Rate Of Change', + 'defaultTimeValuePairs' => { 4.0 => 0.0, 6.0 => 6.0, 8.0 => 15.0, 16 => 7.0, 24 => 0.0 } + } + input_schedule = model_create_simple_schedule(model, test_options) + output_schedule = model_create_schedule_from_rate_of_change(model, input_schedule) + assert(output_schedule.to_ScheduleRuleset.is_initialized) + end + + def test_model_create_weighted_merge_schedules + model = OpenStudio::Model::Model.new + schedule1_options = { + 'name' => 'Schedule1', + 'defaultTimeValuePairs' => { 8.0 => 0.0, 16.0 => 10.0, 24.0 => 0.0 } + } + schedule1 = model_create_simple_schedule(model, schedule1_options) + + schedule2_options = { + 'name' => 'Schedule2', + 'defaultTimeValuePairs' => { 8.0 => 0.0, 16.0 => 20.0, 24.0 => 0.0 } + } + schedule2 = model_create_simple_schedule(model, schedule2_options) + + schedule_weights_hash = {} + schedule_weights_hash[schedule1] = 2 + schedule_weights_hash[schedule2] = 8 + + schedule = model_create_weighted_merge_schedules(model, schedule_weights_hash) + assert(schedule['mergedSchedule'].to_ScheduleRuleset.is_initialized) + assert(schedule['mergedSchedule'].name.to_s == 'Merged Schedule') + assert(schedule['denominator'] == 10.0) + end +end \ No newline at end of file diff --git a/test/schedules/test_schedules_information.rb b/test/schedules/test_schedules_information.rb new file mode 100644 index 0000000000..c27d134b3f --- /dev/null +++ b/test/schedules/test_schedules_information.rb @@ -0,0 +1,36 @@ +require_relative '../helpers/minitest_helper' +require_relative '../../lib/openstudio-standards/schedules/create' +require_relative '../../lib/openstudio-standards/schedules/information' + +class TestSchedulesModify < Minitest::Test + include OpenstudioStandards::Schedules::Create + include OpenstudioStandards::Schedules::Information + + def test_schedule_ruleset_min_max + model = OpenStudio::Model::Model.new + test_options = { + 'name' => 'Simple Schedule', + 'winterTimeValuePairs' => { 8.0 => 4.0, 16.0 => 12.0, 24.0 => 5.0 }, + 'summerTimeValuePairs' => { 8.0 => 2.0, 16.0 => 10.0, 24.0 => 3.0 }, + 'defaultTimeValuePairs' => { 8.0 => 6.0, 16.0 => 14.0, 24.0 => 7.0 } + } + schedule = model_create_simple_schedule(model, test_options) + result = schedule_ruleset_min_max(schedule) + assert(result['min'] == 6.0) + assert(result['max'] == 14.0) + end + + def test_schedule_ruleset_timeseries + model = OpenStudio::Model::Model.new + test_options = { + 'name' => 'Simple Schedule', + 'winterTimeValuePairs' => { 8.0 => 4.0, 16.0 => 12.0, 24.0 => 5.0 }, + 'summerTimeValuePairs' => { 8.0 => 2.0, 16.0 => 10.0, 24.0 => 3.0 }, + 'defaultTimeValuePairs' => { 8.0 => 6.0, 16.0 => 14.0, 24.0 => 7.0 } + } + schedule = model_create_simple_schedule(model, test_options) + result = schedule_ruleset_timeseries(schedule) + assert(result.class.to_s == 'OpenStudio::TimeSeries') + assert(result.values.length == (8760*2 - 365)) + end +end \ No newline at end of file diff --git a/test/schedules/test_schedules_modify.rb b/test/schedules/test_schedules_modify.rb new file mode 100644 index 0000000000..5deb18be5b --- /dev/null +++ b/test/schedules/test_schedules_modify.rb @@ -0,0 +1,70 @@ +require_relative '../helpers/minitest_helper' +require_relative '../../lib/openstudio-standards/schedules/create' +require_relative '../../lib/openstudio-standards/schedules/modify' +require_relative '../../lib/openstudio-standards/schedules/information' + +class TestSchedulesModify < Minitest::Test + include OpenstudioStandards::Schedules::Create + include OpenstudioStandards::Schedules::Modify + include OpenstudioStandards::Schedules::Information + + def test_schedule_ruleset_simple_value_adjust + model = OpenStudio::Model::Model.new + test_options = { + 'name' => 'Simple Schedule', + 'defaultTimeValuePairs' => { 8.0 => 0.0, 16.0 => 3.0, 24.0 => 0.0 } + } + schedule = model_create_simple_schedule(model, test_options) + schedule_ruleset_simple_value_adjust(schedule, 0.5) + assert(schedule.to_ScheduleRuleset.is_initialized) + schedule_max = schedule_ruleset_min_max(schedule)['max'] + assert(schedule_max == 1.5) + + schedule_ruleset_simple_value_adjust(schedule, 0.5, 'Sum') + assert(schedule.to_ScheduleRuleset.is_initialized) + schedule_max = schedule_ruleset_min_max(schedule)['max'] + assert(schedule_max == 2.0) + end + + def test_schedule_ruleset_conditional_adjust_value + model = OpenStudio::Model::Model.new + test_options = { + 'name' => 'Simple Schedule', + 'defaultTimeValuePairs' => { 8.0 => 0.0, 12 => 2.0, 16.0 => 4.0, 24.0 => 0.0 } + } + schedule = model_create_simple_schedule(model, test_options) + test_value = 3.0 + pass_value = 1.5 + fail_value = 2.0 + floor_value = 0.1 + schedule_ruleset_conditional_adjust_value(schedule, test_value, pass_value, fail_value, floor_value) + schedule_max = schedule_ruleset_min_max(schedule)['max'] + assert(schedule_max == 8.0) + end + + def test_schedule_ruleset_time_conditional_adjust_value + model = OpenStudio::Model::Model.new + test_options = { + 'name' => 'Simple Schedule', + 'defaultTimeValuePairs' => { 8.0 => 0.0, 16.0 => 3.0, 24.0 => 0.0 } + } + schedule = model_create_simple_schedule(model, test_options) + hhmm_before = 1400 + hhmm_after = 2030 + inside_value = 2.0 + outside_value = 1.0 + schedule_ruleset_time_conditional_adjust_value(schedule, hhmm_before, hhmm_after, inside_value, outside_value) + end + + def test_schedule_ruleset_adjust_hours_of_operation + model = OpenStudio::Model::Model.new + test_options = { + 'name' => 'Simple Schedule', + 'defaultTimeValuePairs' => { 8.0 => 0.0, 16.0 => 3.0, 24.0 => 0.0 } + } + schedule = model_create_simple_schedule(model, test_options) + basic_shift = { 'shift_hoo' => 2.0 } + schedule_ruleset_adjust_hours_of_operation(schedule, basic_shift) + model.save('test_schedule_ruleset_adjust_hours_of_operation.osm') + end +end \ No newline at end of file From 67eb89885c3c2f85d559625b4dc6dc6065a70543 Mon Sep 17 00:00:00 2001 From: Matthew Dahlhausen Date: Tue, 12 Sep 2023 12:35:53 -0600 Subject: [PATCH 35/45] remove one schedule module level switch to object methods add yard documentation edits --- .yardopts | 1 + lib/openstudio-standards.rb | 5 + lib/openstudio-standards/schedules/create.rb | 632 +++++++------- .../schedules/information.rb | 115 ++- lib/openstudio-standards/schedules/modify.rb | 801 +++++++++--------- test/schedules/test_schedules_create.rb | 21 +- test/schedules/test_schedules_information.rb | 15 +- test/schedules/test_schedules_modify.rb | 34 +- 8 files changed, 812 insertions(+), 812 deletions(-) diff --git a/.yardopts b/.yardopts index 8d19bd1700..083b205779 100644 --- a/.yardopts +++ b/.yardopts @@ -16,6 +16,7 @@ lib/openstudio-standards/prototypes/**/*.rb lib/openstudio-standards/utilities/**/*.rb lib/openstudio-standards/weather/**/*.rb lib/openstudio-standards/refs/references.rb +lib/openstudio-standards/schedules/*.rb - docs/Home.md docs/UserQuickStartGuide.md diff --git a/lib/openstudio-standards.rb b/lib/openstudio-standards.rb index 1043b37708..e796957cce 100644 --- a/lib/openstudio-standards.rb +++ b/lib/openstudio-standards.rb @@ -5,6 +5,11 @@ module OpenstudioStandards require 'json' # Used to load standards JSON files + # Load Modules + require_relative 'openstudio-standards/schedules/create' + require_relative 'openstudio-standards/schedules/modify' + require_relative 'openstudio-standards/schedules/information' + # Weather data require_relative 'openstudio-standards/weather/Weather.Model' diff --git a/lib/openstudio-standards/schedules/create.rb b/lib/openstudio-standards/schedules/create.rb index a31051def4..caf98ce525 100644 --- a/lib/openstudio-standards/schedules/create.rb +++ b/lib/openstudio-standards/schedules/create.rb @@ -1,365 +1,365 @@ # Methods to create Schedule objects module OpenstudioStandards module Schedules - module Create - # create a ruleset schedule with a basic profile - # - # @param model [OpenStudio::Model::Model] OpenStudio model object - # @param options [Hash] Hash of name and time value pairs - # @return [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object - def model_create_simple_schedule(model, options = {}) - defaults = { - 'name' => nil, - 'winterTimeValuePairs' => { 24.0 => 0.0 }, - 'summerTimeValuePairs' => { 24.0 => 1.0 }, - 'defaultTimeValuePairs' => { 24.0 => 1.0 } - } - - # merge user inputs with defaults - options = defaults.merge(options) - - # ScheduleRuleset - sch_ruleset = OpenStudio::Model::ScheduleRuleset.new(model) - if name - sch_ruleset.setName(options['name']) - end + # @!group Create + + # create a ruleset schedule with a basic profile + # + # @param model [OpenStudio::Model::Model] OpenStudio model object + # @param options [Hash] Hash of name and time value pairs + # @return [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object + def self.model_create_simple_schedule(model, options = {}) + defaults = { + 'name' => nil, + 'winterTimeValuePairs' => { 24.0 => 0.0 }, + 'summerTimeValuePairs' => { 24.0 => 1.0 }, + 'defaultTimeValuePairs' => { 24.0 => 1.0 } + } + + # merge user inputs with defaults + options = defaults.merge(options) + + # ScheduleRuleset + sch_ruleset = OpenStudio::Model::ScheduleRuleset.new(model) + if name + sch_ruleset.setName(options['name']) + end + + # Winter Design Day + winter_dsn_day = OpenStudio::Model::ScheduleDay.new(model) + sch_ruleset.setWinterDesignDaySchedule(winter_dsn_day) + winter_dsn_day = sch_ruleset.winterDesignDaySchedule + winter_dsn_day.setName("#{sch_ruleset.name} Winter Design Day") + options['winterTimeValuePairs'].each do |k, v| + hour = k.truncate + min = ((k - hour) * 60).to_i + winter_dsn_day.addValue(OpenStudio::Time.new(0, hour, min, 0), v) + end + + # Summer Design Day + summer_dsn_day = OpenStudio::Model::ScheduleDay.new(model) + sch_ruleset.setSummerDesignDaySchedule(summer_dsn_day) + summer_dsn_day = sch_ruleset.summerDesignDaySchedule + summer_dsn_day.setName("#{sch_ruleset.name} Summer Design Day") + options['summerTimeValuePairs'].each do |k, v| + hour = k.truncate + min = ((k - hour) * 60).to_i + summer_dsn_day.addValue(OpenStudio::Time.new(0, hour, min, 0), v) + end + + # All Days + default_day = sch_ruleset.defaultDaySchedule + default_day.setName("#{sch_ruleset.name} Schedule Week Day") + options['defaultTimeValuePairs'].each do |k, v| + hour = k.truncate + min = ((k - hour) * 60).to_i + default_day.addValue(OpenStudio::Time.new(0, hour, min, 0), v) + end + + return sch_ruleset + end + + # create a ruleset schedule with a complex profile + # + # @param model [OpenStudio::Model::Model] OpenStudio model object + # @param options [Hash] Hash of name and time value pairs + # @return [OpenStudio::Model::ScheduleRuleset] OpenStudio ruleset schedule object + def self.model_create_complex_schedule(model, options = {}) + defaults = { + 'name' => nil, + 'default_day' => ['always_on', [24.0, 1.0]] + } + + # merge user inputs with defaults + options = defaults.merge(options) + + # ScheduleRuleset + sch_ruleset = OpenStudio::Model::ScheduleRuleset.new(model) + if name + sch_ruleset.setName(options['name']) + end - # Winter Design Day + # Winter Design Day + unless options['winter_design_day'].nil? winter_dsn_day = OpenStudio::Model::ScheduleDay.new(model) sch_ruleset.setWinterDesignDaySchedule(winter_dsn_day) winter_dsn_day = sch_ruleset.winterDesignDaySchedule winter_dsn_day.setName("#{sch_ruleset.name} Winter Design Day") - options['winterTimeValuePairs'].each do |k, v| - hour = k.truncate - min = ((k - hour) * 60).to_i - winter_dsn_day.addValue(OpenStudio::Time.new(0, hour, min, 0), v) + options['winter_design_day'].each do |data_pair| + hour = data_pair[0].truncate + min = ((data_pair[0] - hour) * 60).to_i + winter_dsn_day.addValue(OpenStudio::Time.new(0, hour, min, 0), data_pair[1]) end + end - # Summer Design Day + # Summer Design Day + unless options['summer_design_day'].nil? summer_dsn_day = OpenStudio::Model::ScheduleDay.new(model) sch_ruleset.setSummerDesignDaySchedule(summer_dsn_day) summer_dsn_day = sch_ruleset.summerDesignDaySchedule summer_dsn_day.setName("#{sch_ruleset.name} Summer Design Day") - options['summerTimeValuePairs'].each do |k, v| - hour = k.truncate - min = ((k - hour) * 60).to_i - summer_dsn_day.addValue(OpenStudio::Time.new(0, hour, min, 0), v) - end - - # All Days - default_day = sch_ruleset.defaultDaySchedule - default_day.setName("#{sch_ruleset.name} Schedule Week Day") - options['defaultTimeValuePairs'].each do |k, v| - hour = k.truncate - min = ((k - hour) * 60).to_i - default_day.addValue(OpenStudio::Time.new(0, hour, min, 0), v) + options['summer_design_day'].each do |data_pair| + hour = data_pair[0].truncate + min = ((data_pair[0] - hour) * 60).to_i + summer_dsn_day.addValue(OpenStudio::Time.new(0, hour, min, 0), data_pair[1]) end - - return sch_ruleset end - # create a ruleset schedule with a complex profile - # - # @param model [OpenStudio::Model::Model] OpenStudio model object - # @param options [Hash] Hash of name and time value pairs - # @return [OpenStudio::Model::ScheduleRuleset] OpenStudio ruleset schedule object - def model_create_complex_schedule(model, options = {}) - defaults = { - 'name' => nil, - 'default_day' => ['always_on', [24.0, 1.0]] - } - - # merge user inputs with defaults - options = defaults.merge(options) - - # ScheduleRuleset - sch_ruleset = OpenStudio::Model::ScheduleRuleset.new(model) - if name - sch_ruleset.setName(options['name']) - end - - # Winter Design Day - unless options['winter_design_day'].nil? - winter_dsn_day = OpenStudio::Model::ScheduleDay.new(model) - sch_ruleset.setWinterDesignDaySchedule(winter_dsn_day) - winter_dsn_day = sch_ruleset.winterDesignDaySchedule - winter_dsn_day.setName("#{sch_ruleset.name} Winter Design Day") - options['winter_design_day'].each do |data_pair| - hour = data_pair[0].truncate - min = ((data_pair[0] - hour) * 60).to_i - winter_dsn_day.addValue(OpenStudio::Time.new(0, hour, min, 0), data_pair[1]) - end - end + # Default Day + default_day = sch_ruleset.defaultDaySchedule + default_day.setName("#{sch_ruleset.name} #{options['default_day'][0]}") + default_data_array = options['default_day'] + default_data_array.delete_at(0) + default_data_array.each do |data_pair| + hour = data_pair[0].truncate + min = ((data_pair[0] - hour) * 60).to_i + default_day.addValue(OpenStudio::Time.new(0, hour, min, 0), data_pair[1]) + end - # Summer Design Day - unless options['summer_design_day'].nil? - summer_dsn_day = OpenStudio::Model::ScheduleDay.new(model) - sch_ruleset.setSummerDesignDaySchedule(summer_dsn_day) - summer_dsn_day = sch_ruleset.summerDesignDaySchedule - summer_dsn_day.setName("#{sch_ruleset.name} Summer Design Day") - options['summer_design_day'].each do |data_pair| + # Rules + unless options['rules'].nil? + options['rules'].each do |data_array| + rule = OpenStudio::Model::ScheduleRule.new(sch_ruleset) + rule.setName("#{sch_ruleset.name} #{data_array[0]} Rule") + date_range = data_array[1].split('-') + start_date = date_range[0].split('/') + end_date = date_range[1].split('/') + rule.setStartDate(model.getYearDescription.makeDate(start_date[0].to_i, start_date[1].to_i)) + rule.setEndDate(model.getYearDescription.makeDate(end_date[0].to_i, end_date[1].to_i)) + days = data_array[2].split('/') + rule.setApplySunday(true) if days.include? 'Sun' + rule.setApplyMonday(true) if days.include? 'Mon' + rule.setApplyTuesday(true) if days.include? 'Tue' + rule.setApplyWednesday(true) if days.include? 'Wed' + rule.setApplyThursday(true) if days.include? 'Thu' + rule.setApplyFriday(true) if days.include? 'Fri' + rule.setApplySaturday(true) if days.include? 'Sat' + day_schedule = rule.daySchedule + day_schedule.setName("#{sch_ruleset.name} #{data_array[0]}") + data_array.delete_at(0) + data_array.delete_at(0) + data_array.delete_at(0) + data_array.each do |data_pair| hour = data_pair[0].truncate min = ((data_pair[0] - hour) * 60).to_i - summer_dsn_day.addValue(OpenStudio::Time.new(0, hour, min, 0), data_pair[1]) + day_schedule.addValue(OpenStudio::Time.new(0, hour, min, 0), data_pair[1]) end end + end - # Default Day - default_day = sch_ruleset.defaultDaySchedule - default_day.setName("#{sch_ruleset.name} #{options['default_day'][0]}") - default_data_array = options['default_day'] - default_data_array.delete_at(0) - default_data_array.each do |data_pair| - hour = data_pair[0].truncate - min = ((data_pair[0] - hour) * 60).to_i - default_day.addValue(OpenStudio::Time.new(0, hour, min, 0), data_pair[1]) - end - - # Rules - unless options['rules'].nil? - options['rules'].each do |data_array| - rule = OpenStudio::Model::ScheduleRule.new(sch_ruleset) - rule.setName("#{sch_ruleset.name} #{data_array[0]} Rule") - date_range = data_array[1].split('-') - start_date = date_range[0].split('/') - end_date = date_range[1].split('/') - rule.setStartDate(model.getYearDescription.makeDate(start_date[0].to_i, start_date[1].to_i)) - rule.setEndDate(model.getYearDescription.makeDate(end_date[0].to_i, end_date[1].to_i)) - days = data_array[2].split('/') - rule.setApplySunday(true) if days.include? 'Sun' - rule.setApplyMonday(true) if days.include? 'Mon' - rule.setApplyTuesday(true) if days.include? 'Tue' - rule.setApplyWednesday(true) if days.include? 'Wed' - rule.setApplyThursday(true) if days.include? 'Thu' - rule.setApplyFriday(true) if days.include? 'Fri' - rule.setApplySaturday(true) if days.include? 'Sat' - day_schedule = rule.daySchedule - day_schedule.setName("#{sch_ruleset.name} #{data_array[0]}") - data_array.delete_at(0) - data_array.delete_at(0) - data_array.delete_at(0) - data_array.each do |data_pair| - hour = data_pair[0].truncate - min = ((data_pair[0] - hour) * 60).to_i - day_schedule.addValue(OpenStudio::Time.new(0, hour, min, 0), data_pair[1]) - end - end - end + return sch_ruleset + end - return sch_ruleset + # create a new schedule using absolute velocity of existing schedule + # + # @param model [OpenStudio::Model::Model] OpenStudio model object + # @param schedule [OpenStudio::Model::ScheduleRuleset] OpenStudio ruleset schedule object + # @return [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object + # @todo fix velocity so it isn't fraction change per step, but per hour + # (I need to count hours between times and divide value by this) + def self.model_create_schedule_from_rate_of_change(model, schedule_ruleset) + # clone source schedule + new_schedule = schedule_ruleset.clone(model) + new_schedule.setName("#{schedule_ruleset.name} - Rate of Change") + new_schedule = new_schedule.to_ScheduleRuleset.get + + # create array of all profiles to change. This includes summer, winter, default, and rules + profiles = [] + profiles << new_schedule.winterDesignDaySchedule + profiles << new_schedule.summerDesignDaySchedule + profiles << new_schedule.defaultDaySchedule + + # time values may need + end_profile_time = OpenStudio::Time.new(0, 24, 0, 0) + hour_bump_time = OpenStudio::Time.new(0, 1, 0, 0) + one_hour_left_time = OpenStudio::Time.new(0, 23, 0, 0) + + rules = new_schedule.scheduleRules + rules.each do |rule| + profiles << rule.daySchedule end - # create a new schedule using absolute velocity of existing schedule - # - # @param model [OpenStudio::Model::Model] OpenStudio model object - # @param schedule [OpenStudio::Model::ScheduleRuleset] OpenStudio ruleset schedule object - # @return [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object - # @todo fix velocity so it isn't fraction change per step, but per hour - # (I need to count hours between times and divide value by this) - def model_create_schedule_from_rate_of_change(model, schedule_ruleset) - # clone source schedule - new_schedule = schedule_ruleset.clone(model) - new_schedule.setName("#{schedule_ruleset.name} - Rate of Change") - new_schedule = new_schedule.to_ScheduleRuleset.get - - # create array of all profiles to change. This includes summer, winter, default, and rules - profiles = [] - profiles << new_schedule.winterDesignDaySchedule - profiles << new_schedule.summerDesignDaySchedule - profiles << new_schedule.defaultDaySchedule - - # time values may need - end_profile_time = OpenStudio::Time.new(0, 24, 0, 0) - hour_bump_time = OpenStudio::Time.new(0, 1, 0, 0) - one_hour_left_time = OpenStudio::Time.new(0, 23, 0, 0) - - rules = new_schedule.scheduleRules - rules.each do |rule| - profiles << rule.daySchedule - end - - profiles.uniq.each do |profile| - times = profile.times - values = profile.values - - i = 0 - values_intermediate = [] - times_intermediate = [] - until i == values.size - if i == 0 - values_intermediate << 0.0 - if times[i] > hour_bump_time - times_intermediate << times[i] - hour_bump_time - if times[i + 1].nil? - time_step_value = end_profile_time.hours + end_profile_time.minutes / 60 - times[i].hours - times[i].minutes / 60 - else - time_step_value = times[i + 1].hours + times[i + 1].minutes / 60 - times[i].hours - times[i].minutes / 60 - end - values_intermediate << (values[i + 1].to_f - values[i].to_f).abs / (time_step_value * 2) - end - times_intermediate << times[i] - elsif i == (values.size - 1) - if times[times.size - 2] < one_hour_left_time - times_intermediate << times[times.size - 2] + hour_bump_time # this should be the second to last time - time_step_value = times[i - 1].hours + times[i - 1].minutes / 60 - times[i - 2].hours - times[i - 2].minutes / 60 - values_intermediate << (values[i - 1].to_f - values[i - 2].to_f).abs / (time_step_value * 2) + profiles.uniq.each do |profile| + times = profile.times + values = profile.values + + i = 0 + values_intermediate = [] + times_intermediate = [] + until i == values.size + if i == 0 + values_intermediate << 0.0 + if times[i] > hour_bump_time + times_intermediate << times[i] - hour_bump_time + if times[i + 1].nil? + time_step_value = end_profile_time.hours + end_profile_time.minutes / 60 - times[i].hours - times[i].minutes / 60 + else + time_step_value = times[i + 1].hours + times[i + 1].minutes / 60 - times[i].hours - times[i].minutes / 60 end - values_intermediate << 0.0 - times_intermediate << times[i] # this should be the last time - else - # get value multiplier based on how many hours it is spread over - time_step_value = times[i].hours + times[i].minutes / 60 - times[i - 1].hours - times[i - 1].minutes / 60 - values_intermediate << (values[i].to_f - values[i - 1].to_f).abs / time_step_value - times_intermediate << times[i] + values_intermediate << (values[i + 1].to_f - values[i].to_f).abs / (time_step_value * 2) end - i += 1 - end - - # delete all profile values - profile.clearValues - - i = 0 - until i == times_intermediate.size - if i == (times_intermediate.size - 1) - profile.addValue(times_intermediate[i], values_intermediate[i].to_f) - else - profile.addValue(times_intermediate[i], values_intermediate[i].to_f) + times_intermediate << times[i] + elsif i == (values.size - 1) + if times[times.size - 2] < one_hour_left_time + times_intermediate << times[times.size - 2] + hour_bump_time # this should be the second to last time + time_step_value = times[i - 1].hours + times[i - 1].minutes / 60 - times[i - 2].hours - times[i - 2].minutes / 60 + values_intermediate << (values[i - 1].to_f - values[i - 2].to_f).abs / (time_step_value * 2) end - i += 1 + values_intermediate << 0.0 + times_intermediate << times[i] # this should be the last time + else + # get value multiplier based on how many hours it is spread over + time_step_value = times[i].hours + times[i].minutes / 60 - times[i - 1].hours - times[i - 1].minutes / 60 + values_intermediate << (values[i].to_f - values[i - 1].to_f).abs / time_step_value + times_intermediate << times[i] end + i += 1 end - return new_schedule - end + # delete all profile values + profile.clearValues - # merge multiple schedules into one using load or other value to weight each schedules influence on the merge - # - # @param model [OpenStudio::Model::Model] OpenStudio model object - # @param schedule_weights_hash [Hash] Array of hashes of {OpenStudio::Model::ScheduleRuleset, Double} - # @sch_name [String] Optional name of new schedule - # @return [Hash] Hash of {OpenStudio::Model::ScheduleRuleset, Double} - # with the OpenStudio ScheduleRuleset object and the total denominator - # @todo apply weights to schedule rules as well, not just winter, summer, and default profile - def model_create_weighted_merge_schedules(model, schedule_weights_hash, sch_name: 'Merged Schedule') - # get denominator for weight - denominator = 0.0 - schedule_weights_hash.each do |schedule, weight| - denominator += weight + i = 0 + until i == times_intermediate.size + if i == (times_intermediate.size - 1) + profile.addValue(times_intermediate[i], values_intermediate[i].to_f) + else + profile.addValue(times_intermediate[i], values_intermediate[i].to_f) + end + i += 1 end + end - # create new schedule - sch_ruleset = OpenStudio::Model::ScheduleRuleset.new(model) - sch_ruleset.setName(sch_name) - - # create winter design day profile - winter_dsn_day = OpenStudio::Model::ScheduleDay.new(model) - sch_ruleset.setWinterDesignDaySchedule(winter_dsn_day) - winter_dsn_day = sch_ruleset.winterDesignDaySchedule - winter_dsn_day.setName("#{sch_ruleset.name} Winter Design Day") + return new_schedule + end - # create summer design day profile - summer_dsn_day = OpenStudio::Model::ScheduleDay.new(model) - sch_ruleset.setSummerDesignDaySchedule(summer_dsn_day) - summer_dsn_day = sch_ruleset.summerDesignDaySchedule - summer_dsn_day.setName("#{sch_ruleset.name} Summer Design Day") + # merge multiple schedules into one using load or other value to weight each schedules influence on the merge + # + # @param model [OpenStudio::Model::Model] OpenStudio model object + # @param schedule_weights_hash [Hash] Array of hashes of {OpenStudio::Model::ScheduleRuleset, Double} + # @sch_name [String] Optional name of new schedule + # @return [Hash] Hash of {OpenStudio::Model::ScheduleRuleset, Double} + # with the OpenStudio ScheduleRuleset object and the total denominator + # @todo apply weights to schedule rules as well, not just winter, summer, and default profile + def self.model_create_weighted_merge_schedules(model, schedule_weights_hash, sch_name: 'Merged Schedule') + # get denominator for weight + denominator = 0.0 + schedule_weights_hash.each do |schedule, weight| + denominator += weight + end - # create default profile - default_day = sch_ruleset.defaultDaySchedule - default_day.setName("#{sch_ruleset.name} Schedule Week Day") - - # hash of schedule rules - rules_hash = {} # mon, tue, wed, thur, fri, sat, sun, startDate, endDate - # to avoid stacking order issues across schedules, I may need to make a rule for each day of the week for each date range - - schedule_weights_hash.each do |schedule, weight| - # populate winter design day profile - old_winter_profile = schedule.to_ScheduleRuleset.get.winterDesignDaySchedule - times_final = summer_dsn_day.times - i = 0 - value_updated_array = [] - # loop through times already in profile and update values - until i > times_final.size - 1 - value = old_winter_profile.getValue(times_final[i]) * weight / denominator - starting_value = winter_dsn_day.getValue(times_final[i]) - winter_dsn_day.addValue(times_final[i], value + starting_value) - value_updated_array << times_final[i] - i += 1 - end - # loop through any new times unique to the current old profile to be merged - j = 0 - times = old_winter_profile.times - values = old_winter_profile.values - until j > times.size - 1 - unless value_updated_array.include? times[j] - value = values[j] * weight / denominator - starting_value = winter_dsn_day.getValue(times[j]) - winter_dsn_day.addValue(times[j], value + starting_value) - end - j += 1 + # create new schedule + sch_ruleset = OpenStudio::Model::ScheduleRuleset.new(model) + sch_ruleset.setName(sch_name) + + # create winter design day profile + winter_dsn_day = OpenStudio::Model::ScheduleDay.new(model) + sch_ruleset.setWinterDesignDaySchedule(winter_dsn_day) + winter_dsn_day = sch_ruleset.winterDesignDaySchedule + winter_dsn_day.setName("#{sch_ruleset.name} Winter Design Day") + + # create summer design day profile + summer_dsn_day = OpenStudio::Model::ScheduleDay.new(model) + sch_ruleset.setSummerDesignDaySchedule(summer_dsn_day) + summer_dsn_day = sch_ruleset.summerDesignDaySchedule + summer_dsn_day.setName("#{sch_ruleset.name} Summer Design Day") + + # create default profile + default_day = sch_ruleset.defaultDaySchedule + default_day.setName("#{sch_ruleset.name} Schedule Week Day") + + # hash of schedule rules + rules_hash = {} # mon, tue, wed, thur, fri, sat, sun, startDate, endDate + # to avoid stacking order issues across schedules, I may need to make a rule for each day of the week for each date range + + schedule_weights_hash.each do |schedule, weight| + # populate winter design day profile + old_winter_profile = schedule.to_ScheduleRuleset.get.winterDesignDaySchedule + times_final = summer_dsn_day.times + i = 0 + value_updated_array = [] + # loop through times already in profile and update values + until i > times_final.size - 1 + value = old_winter_profile.getValue(times_final[i]) * weight / denominator + starting_value = winter_dsn_day.getValue(times_final[i]) + winter_dsn_day.addValue(times_final[i], value + starting_value) + value_updated_array << times_final[i] + i += 1 + end + # loop through any new times unique to the current old profile to be merged + j = 0 + times = old_winter_profile.times + values = old_winter_profile.values + until j > times.size - 1 + unless value_updated_array.include? times[j] + value = values[j] * weight / denominator + starting_value = winter_dsn_day.getValue(times[j]) + winter_dsn_day.addValue(times[j], value + starting_value) end + j += 1 + end - # populate summer design day profile - old_summer_profile = schedule.to_ScheduleRuleset.get.summerDesignDaySchedule - times_final = summer_dsn_day.times - i = 0 - value_updated_array = [] - # loop through times already in profile and update values - until i > times_final.size - 1 - value = old_summer_profile.getValue(times_final[i]) * weight / denominator - starting_value = summer_dsn_day.getValue(times_final[i]) - summer_dsn_day.addValue(times_final[i], value + starting_value) - value_updated_array << times_final[i] - i += 1 - end - # loop through any new times unique to the current old profile to be merged - j = 0 - times = old_summer_profile.times - values = old_summer_profile.values - until j > times.size - 1 - unless value_updated_array.include? times[j] - value = values[j] * weight / denominator - starting_value = summer_dsn_day.getValue(times[j]) - summer_dsn_day.addValue(times[j], value + starting_value) - end - j += 1 + # populate summer design day profile + old_summer_profile = schedule.to_ScheduleRuleset.get.summerDesignDaySchedule + times_final = summer_dsn_day.times + i = 0 + value_updated_array = [] + # loop through times already in profile and update values + until i > times_final.size - 1 + value = old_summer_profile.getValue(times_final[i]) * weight / denominator + starting_value = summer_dsn_day.getValue(times_final[i]) + summer_dsn_day.addValue(times_final[i], value + starting_value) + value_updated_array << times_final[i] + i += 1 + end + # loop through any new times unique to the current old profile to be merged + j = 0 + times = old_summer_profile.times + values = old_summer_profile.values + until j > times.size - 1 + unless value_updated_array.include? times[j] + value = values[j] * weight / denominator + starting_value = summer_dsn_day.getValue(times[j]) + summer_dsn_day.addValue(times[j], value + starting_value) end + j += 1 + end - # populate default profile - old_default_profile = schedule.to_ScheduleRuleset.get.defaultDaySchedule - times_final = default_day.times - i = 0 - value_updated_array = [] - # loop through times already in profile and update values - until i > times_final.size - 1 - value = old_default_profile.getValue(times_final[i]) * weight / denominator - starting_value = default_day.getValue(times_final[i]) - default_day.addValue(times_final[i], value + starting_value) - value_updated_array << times_final[i] - i += 1 - end - # loop through any new times unique to the current old profile to be merged - j = 0 - times = old_default_profile.times - values = old_default_profile.values - until j > times.size - 1 - unless value_updated_array.include? times[j] - value = values[j] * weight / denominator - starting_value = default_day.getValue(times[j]) - default_day.addValue(times[j], value + starting_value) - end - j += 1 + # populate default profile + old_default_profile = schedule.to_ScheduleRuleset.get.defaultDaySchedule + times_final = default_day.times + i = 0 + value_updated_array = [] + # loop through times already in profile and update values + until i > times_final.size - 1 + value = old_default_profile.getValue(times_final[i]) * weight / denominator + starting_value = default_day.getValue(times_final[i]) + default_day.addValue(times_final[i], value + starting_value) + value_updated_array << times_final[i] + i += 1 + end + # loop through any new times unique to the current old profile to be merged + j = 0 + times = old_default_profile.times + values = old_default_profile.values + until j > times.size - 1 + unless value_updated_array.include? times[j] + value = values[j] * weight / denominator + starting_value = default_day.getValue(times[j]) + default_day.addValue(times[j], value + starting_value) end + j += 1 + end - # create rules - - # gather data for rule profiles + # create rules - # populate rule profiles - end + # gather data for rule profiles - result = { 'mergedSchedule' => sch_ruleset, 'denominator' => denominator } - return result + # populate rule profiles end + + result = { 'mergedSchedule' => sch_ruleset, 'denominator' => denominator } + return result end end end \ No newline at end of file diff --git a/lib/openstudio-standards/schedules/information.rb b/lib/openstudio-standards/schedules/information.rb index 7e9fc9b84c..93b53ea547 100644 --- a/lib/openstudio-standards/schedules/information.rb +++ b/lib/openstudio-standards/schedules/information.rb @@ -2,76 +2,75 @@ # Many of these methods may be moved to core OpenStudio module OpenstudioStandards module Schedules - module Information + # @!group Information - # add general schedule_min_max(schedule) method and merge with other methods + # add general schedule_min_max(schedule) method and merge with other methods - # returns the schedule ruleset minimum and maximum values - # - # @param schedule_ruleset [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object - # @return [Hash] returns as hash with 'min' and 'max' values - def schedule_ruleset_min_max(schedule_ruleset) - # validate schedule - if schedule_ruleset.to_ScheduleRuleset.is_initialized - schedule = schedule_ruleset.to_ScheduleRuleset.get + # returns the schedule ruleset minimum and maximum values + # + # @param schedule_ruleset [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object + # @return [Hash] returns as hash with 'min' and 'max' values + def self.schedule_ruleset_min_max(schedule_ruleset) + # validate schedule + if schedule_ruleset.to_ScheduleRuleset.is_initialized + schedule = schedule_ruleset.to_ScheduleRuleset.get - # gather profiles - profiles = [] - defaultProfile = schedule.defaultDaySchedule - profiles << defaultProfile - rules = schedule.scheduleRules - rules.each do |rule| - profiles << rule.daySchedule - end + # gather profiles + profiles = [] + defaultProfile = schedule.defaultDaySchedule + profiles << defaultProfile + rules = schedule.scheduleRules + rules.each do |rule| + profiles << rule.daySchedule + end - # test profiles - min = nil - max = nil - profiles.each do |profile| - profile.values.each do |value| - if min.nil? - min = value - else - if min > value then min = value end - end - if max.nil? - max = value - else - if max < value then max = value end - end + # test profiles + min = nil + max = nil + profiles.each do |profile| + profile.values.each do |value| + if min.nil? + min = value + else + if min > value then min = value end + end + if max.nil? + max = value + else + if max < value then max = value end end end - result = { 'min' => min, 'max' => max } # this doesn't include summer and winter design day - else - result = nil end - - return result + result = { 'min' => min, 'max' => max } # this doesn't include summer and winter design day + else + result = nil end - # create TimeSeries from ScheduleRuleset - # - # @param schedule_ruleset [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object - # @return [OpenStudio::TimeSeries] OpenStudio TimeSeries object of schedule values - def schedule_ruleset_timeseries(schedule_ruleset) - yd = schedule_ruleset.model.getYearDescription - start_date = yd.makeDate(1, 1) - end_date = yd.makeDate(12, 31) + return result + end - values = OpenStudio::DoubleVector.new - day = OpenStudio::Time.new(1.0) - interval = OpenStudio::Time.new(1.0 / 48.0) - day_schedules = schedule_ruleset.to_ScheduleRuleset.get.getDaySchedules(start_date, end_date) - day_schedules.each do |day_schedule| - time = interval - while time < day - values << day_schedule.getValue(time) - time += interval - end + # create TimeSeries from ScheduleRuleset + # + # @param schedule_ruleset [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object + # @return [OpenStudio::TimeSeries] OpenStudio TimeSeries object of schedule values + def self.schedule_ruleset_timeseries(schedule_ruleset) + yd = schedule_ruleset.model.getYearDescription + start_date = yd.makeDate(1, 1) + end_date = yd.makeDate(12, 31) + + values = OpenStudio::DoubleVector.new + day = OpenStudio::Time.new(1.0) + interval = OpenStudio::Time.new(1.0 / 48.0) + day_schedules = schedule_ruleset.to_ScheduleRuleset.get.getDaySchedules(start_date, end_date) + day_schedules.each do |day_schedule| + time = interval + while time < day + values << day_schedule.getValue(time) + time += interval end - timeseries = OpenStudio::TimeSeries.new(start_date, interval, OpenStudio.createVector(values), '') - return timeseries end + timeseries = OpenStudio::TimeSeries.new(start_date, interval, OpenStudio.createVector(values), '') + return timeseries end end end \ No newline at end of file diff --git a/lib/openstudio-standards/schedules/modify.rb b/lib/openstudio-standards/schedules/modify.rb index 7dbd4d1c04..cc42b14ea4 100644 --- a/lib/openstudio-standards/schedules/modify.rb +++ b/lib/openstudio-standards/schedules/modify.rb @@ -1,447 +1,446 @@ # Methods to modify existing Schedule objects module OpenstudioStandards module Schedules - module Modify + # @!group Modify - # Increase/decrease by percentage or static value - # - # @param schedule_ruleset [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object - # @param value [Double] Hash of name and time value pairs - # @param modification_type [String] Options are 'Multiplier', which multiples by the value, - # and 'Sum' which adds by the value - # @return [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object - # @todo add in design day adjustments, maybe as an optional argument - # @todo provide option to clone existing schedule - def schedule_ruleset_simple_value_adjust(schedule_ruleset, value, modification_type = 'Multiplier') - # gather profiles - profiles = [] - default_profile = schedule_ruleset.to_ScheduleRuleset.get.defaultDaySchedule - profiles << default_profile - rules = schedule_ruleset.scheduleRules - rules.each do |rule| - profiles << rule.daySchedule - end + # Increase/decrease by percentage or static value + # + # @param schedule_ruleset [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object + # @param value [Double] Hash of name and time value pairs + # @param modification_type [String] Options are 'Multiplier', which multiples by the value, + # and 'Sum' which adds by the value + # @return [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object + # @todo add in design day adjustments, maybe as an optional argument + # @todo provide option to clone existing schedule + def self.schedule_ruleset_simple_value_adjust(schedule_ruleset, value, modification_type = 'Multiplier') + # gather profiles + profiles = [] + default_profile = schedule_ruleset.to_ScheduleRuleset.get.defaultDaySchedule + profiles << default_profile + rules = schedule_ruleset.scheduleRules + rules.each do |rule| + profiles << rule.daySchedule + end - # alter profiles - profiles.each do |profile| - times = profile.times - i = 0 - profile.values.each do |sch_value| - case modification_type - when 'Multiplier', 'Percentage' - # percentage was used early on but Multiplier is preferable - profile.addValue(times[i], sch_value * value) - when 'Sum', 'Value' - # value was used early on but Sum is preferable - profile.addValue(times[i], sch_value + value) - end - i += 1 + # alter profiles + profiles.each do |profile| + times = profile.times + i = 0 + profile.values.each do |sch_value| + case modification_type + when 'Multiplier', 'Percentage' + # percentage was used early on but Multiplier is preferable + profile.addValue(times[i], sch_value * value) + when 'Sum', 'Value' + # value was used early on but Sum is preferable + profile.addValue(times[i], sch_value + value) end + i += 1 end - - return schedule_ruleset end - # Increase/decrease by percentage or static value - # change value when value passes/fails test - # - # @param schedule_ruleset [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object - # @param test_value [Double] if less than the test_value, use the pass_value to modify, otherwise use the fail_value - # @param pass_value [Double] value to adjust by if less than test value - # @param fail_value [Double] value to adjust by if more than test value - # @param floor_value [Double] minimum value that the adjustment can take - # @param modification_type [String] Options are 'Multiplier', which multiples by the value, - # and 'Sum' which adds by the value - # @return [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object - # @todo add in design day adjustments, maybe as an optional argument - # @todo provide option to clone existing schedule - def schedule_ruleset_conditional_adjust_value(schedule_ruleset, test_value, pass_value, fail_value, floor_value, modification_type = 'Multiplier') - # gather profiles - profiles = [] - default_profile = schedule_ruleset.to_ScheduleRuleset.get.defaultDaySchedule - profiles << default_profile - rules = schedule_ruleset.scheduleRules - rules.each do |rule| - profiles << rule.daySchedule - end + return schedule_ruleset + end - # alter profiles - profiles.each do |profile| - times = profile.times - i = 0 + # Increase/decrease by percentage or static value + # change value when value passes/fails test + # + # @param schedule_ruleset [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object + # @param test_value [Double] if less than the test_value, use the pass_value to modify, otherwise use the fail_value + # @param pass_value [Double] value to adjust by if less than test value + # @param fail_value [Double] value to adjust by if more than test value + # @param floor_value [Double] minimum value that the adjustment can take + # @param modification_type [String] Options are 'Multiplier', which multiples by the value, + # and 'Sum' which adds by the value + # @return [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object + # @todo add in design day adjustments, maybe as an optional argument + # @todo provide option to clone existing schedule + def self.schedule_ruleset_conditional_adjust_value(schedule_ruleset, test_value, pass_value, fail_value, floor_value, modification_type = 'Multiplier') + # gather profiles + profiles = [] + default_profile = schedule_ruleset.to_ScheduleRuleset.get.defaultDaySchedule + profiles << default_profile + rules = schedule_ruleset.scheduleRules + rules.each do |rule| + profiles << rule.daySchedule + end - profile.values.each do |sch_value| - # run test on this sch_value - if sch_value < test_value - adjust_value = pass_value - else - adjust_value = fail_value - end + # alter profiles + profiles.each do |profile| + times = profile.times + i = 0 - # skip if sch_value is floor or less - next if sch_value <= floor_value + profile.values.each do |sch_value| + # run test on this sch_value + if sch_value < test_value + adjust_value = pass_value + else + adjust_value = fail_value + end - case modification_type - when 'Multiplier' - # take the max of the floor or resulting value - profile.addValue(times[i], [sch_value * adjust_value, floor_value].max) - when 'Sum' - # take the max of the floor or resulting value - profile.addValue(times[i], [sch_value + adjust_value, floor_value].max) - end - i += 1 + # skip if sch_value is floor or less + next if sch_value <= floor_value + + case modification_type + when 'Multiplier' + # take the max of the floor or resulting value + profile.addValue(times[i], [sch_value * adjust_value, floor_value].max) + when 'Sum' + # take the max of the floor or resulting value + profile.addValue(times[i], [sch_value + adjust_value, floor_value].max) end + i += 1 end - - return schedule_ruleset end - # Increase/decrease by percentage or static value - # change value when time passes test - # - # @param schedule_ruleset [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object - # @param hhmm_before [String] time before string in hhmm format, e.g. 1530 - # @param hhmm_after [String] string in hhmm format, e.g. 1530 - # @param inside_value [Double] - # @param outside_value [Double] - # @param modification_type [String] Options are 'Sum', which adds to the value, - # and 'Replace' which replaces the value - # @return [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object - def schedule_ruleset_time_conditional_adjust_value(schedule_ruleset, hhmm_before, hhmm_after, inside_value, outside_value, modification_type = 'Sum') - # setup variables - array = hhmm_before.to_s.split('') - before_hour = "#{array[0]}#{array[1]}".to_i - before_min = "#{array[2]}#{array[3]}".to_i - array = hhmm_after.to_s.split('') - after_hour = "#{array[0]}#{array[1]}".to_i - after_min = "#{array[2]}#{array[3]}".to_i + return schedule_ruleset + end + + # Increase/decrease by percentage or static value + # change value when time passes test + # + # @param schedule_ruleset [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object + # @param hhmm_before [String] time before string in hhmm format, e.g. 1530 + # @param hhmm_after [String] string in hhmm format, e.g. 1530 + # @param inside_value [Double] + # @param outside_value [Double] + # @param modification_type [String] Options are 'Sum', which adds to the value, + # and 'Replace' which replaces the value + # @return [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object + def self.schedule_ruleset_time_conditional_adjust_value(schedule_ruleset, hhmm_before, hhmm_after, inside_value, outside_value, modification_type = 'Sum') + # setup variables + array = hhmm_before.to_s.split('') + before_hour = "#{array[0]}#{array[1]}".to_i + before_min = "#{array[2]}#{array[3]}".to_i + array = hhmm_after.to_s.split('') + after_hour = "#{array[0]}#{array[1]}".to_i + after_min = "#{array[2]}#{array[3]}".to_i - # gather profiles - profiles = [] - schedule = schedule_ruleset.to_ScheduleRuleset.get - default_profile = schedule_ruleset.defaultDaySchedule - profiles << default_profile - rules = schedule_ruleset.scheduleRules - rules.each do |rule| - profiles << rule.daySchedule - end + # gather profiles + profiles = [] + schedule = schedule_ruleset.to_ScheduleRuleset.get + default_profile = schedule_ruleset.defaultDaySchedule + profiles << default_profile + rules = schedule_ruleset.scheduleRules + rules.each do |rule| + profiles << rule.daySchedule + end - # alter profiles - profiles.each do |day_sch| - times = day_sch.times - i = 0 + # alter profiles + profiles.each do |day_sch| + times = day_sch.times + i = 0 - # set times special times needed for methods below - before_time = OpenStudio::Time.new(0, before_hour, before_min, 0) - after_time = OpenStudio::Time.new(0, after_hour, after_min, 0) - # day_end_time = OpenStudio::Time.new(0, 24, 0, 0) + # set times special times needed for methods below + before_time = OpenStudio::Time.new(0, before_hour, before_min, 0) + after_time = OpenStudio::Time.new(0, after_hour, after_min, 0) + # day_end_time = OpenStudio::Time.new(0, 24, 0, 0) - # add datapoint at before and after time - original_value_at_before_time = day_sch.getValue(before_time) - original_value_at_after_time = day_sch.getValue(after_time) - day_sch.addValue(before_time, original_value_at_before_time) - day_sch.addValue(after_time, original_value_at_after_time) + # add datapoint at before and after time + original_value_at_before_time = day_sch.getValue(before_time) + original_value_at_after_time = day_sch.getValue(after_time) + day_sch.addValue(before_time, original_value_at_before_time) + day_sch.addValue(after_time, original_value_at_after_time) - # make arrays for original times and values - times = day_sch.times - sch_values = day_sch.values - day_sch.clearValues + # make arrays for original times and values + times = day_sch.times + sch_values = day_sch.values + day_sch.clearValues - # make arrays for new values - new_times = [] - new_values = [] + # make arrays for new values + new_times = [] + new_values = [] - # loop through original time/value pairs to populate new array - for i in 0..(sch_values.length - 1) - new_times << times[i] + # loop through original time/value pairs to populate new array + for i in 0..(sch_values.length - 1) + new_times << times[i] - if times[i] > before_time && times[i] <= after_time - # updated this so times[i] == before_time goes into the else - if inside_value.nil? - new_values << sch_values[i] - elsif modification_type == 'Sum' - new_values << inside_value + sch_values[i] - elsif modification_type == 'Replace' - new_values << inside_value - else # should be Multiplier - new_values << inside_value * sch_values[i] - end - else - if outside_value.nil? - new_values << sch_values[i] - elsif modification_type == 'Sum' - new_values << outside_value + sch_values[i] - elsif modification_type == 'Replace' - new_values << outside_value - else # should be Multiplier - new_values << outside_value * sch_values[i] - end + if times[i] > before_time && times[i] <= after_time + # updated this so times[i] == before_time goes into the else + if inside_value.nil? + new_values << sch_values[i] + elsif modification_type == 'Sum' + new_values << inside_value + sch_values[i] + elsif modification_type == 'Replace' + new_values << inside_value + else # should be Multiplier + new_values << inside_value * sch_values[i] + end + else + if outside_value.nil? + new_values << sch_values[i] + elsif modification_type == 'Sum' + new_values << outside_value + sch_values[i] + elsif modification_type == 'Replace' + new_values << outside_value + else # should be Multiplier + new_values << outside_value * sch_values[i] end - end - # generate new day_sch values - for i in 0..(new_values.length - 1) - day_sch.addValue(new_times[i], new_values[i]) - end end - return schedule_ruleset + # generate new day_sch values + for i in 0..(new_values.length - 1) + day_sch.addValue(new_times[i], new_values[i]) + end end - # Adjust hours of operation - # - # @param schedule_ruleset [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object - # @param options [Hash] Hash of argument options - # @return [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object - def schedule_ruleset_adjust_hours_of_operation(schedule_ruleset, options = {}) - defaults = { - 'base_start_hoo' => 8.0, # may not be good idea to have default - 'base_finish_hoo' => 18.0, # may not be good idea to have default - 'delta_length_hoo' => 0.0, - 'shift_hoo' => 0.0, - 'default' => true, - 'mon' => true, - 'tue' => true, - 'wed' => true, - 'thur' => true, - 'fri' => true, - 'sat' => true, - 'sun' => true, - 'summer' => false, - 'winter' => false - } - - # merge user inputs with defaults - options = defaults.merge(options) - - # grab schedule out of argument - if schedule_ruleset.to_ScheduleRuleset.is_initialized - schedule = schedule_ruleset.to_ScheduleRuleset.get - else - OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.Schedules.Modify', "schedule_ruleset_adjust_hours_of_operation only applies to ScheduleRuleset objects. Skipping #{schedule.name}") - return nil - end - - # array of all profiles to change - profiles = [] - - # push default profiles to array - if options['default'] - default_rule = schedule.defaultDaySchedule - profiles << default_rule - end - - # push profiles to array - rules = schedule.scheduleRules - rules.each do |rule| - day_sch = rule.daySchedule - - # if any day requested also exists in the rule, then it will be altered - alter_rule = false - if rule.applyMonday && rule.applyMonday == options['mon'] then alter_rule = true end - if rule.applyTuesday && rule.applyTuesday == options['tue'] then alter_rule = true end - if rule.applyWednesday && rule.applyWednesday == options['wed'] then alter_rule = true end - if rule.applyThursday && rule.applyThursday == options['thur'] then alter_rule = true end - if rule.applyFriday && rule.applyFriday == options['fri'] then alter_rule = true end - if rule.applySaturday && rule.applySaturday == options['sat'] then alter_rule = true end - if rule.applySunday && rule.applySunday == options['sun'] then alter_rule = true end - - # TODO: - add in logic to warn user about conflicts where a single rule has conflicting tests - - if alter_rule - profiles << day_sch - end - end - - # add design days to array - if options['summer'] - summer_design = schedule.summerDesignDaySchedule - profiles << summer_design - end - if options['winter'] - winter_design = schedule.winterDesignDaySchedule - profiles << winter_design - end - - # give info messages as I change specific profiles - OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.Schedules.Modify', "Adjusting #{schedule.name}") - - # rename schedule - schedule.setName("#{schedule.name} - extend #{options['delta_length_hoo']} shift #{options['shift_hoo']}") - - # break time args into hours and minutes - start_hoo_hours = (options['base_start_hoo']).to_i - start_hoo_minutes = (((options['base_start_hoo']) - (options['base_start_hoo']).to_i) * 60).to_i - finish_hoo_hours = (options['base_finish_hoo']).to_i - finish_hoo_minutes = (((options['base_finish_hoo']) - (options['base_finish_hoo']).to_i) * 60).to_i - delta_hours = (options['delta_length_hoo']).to_i - delta_minutes = (((options['delta_length_hoo']) - (options['delta_length_hoo']).to_i) * 60).to_i - shift_hours = (options['shift_hoo']).to_i - shift_minutes = (((options['shift_hoo']) - (options['shift_hoo']).to_i) * 60).to_i - - # time objects to use in measure - time_0 = OpenStudio::Time.new(0, 0, 0, 0) - time_1_min = OpenStudio::Time.new(0, 0, 1, 0) # add this to avoid times in day profile less than this - time_12 = OpenStudio::Time.new(0, 12, 0, 0) - time_24 = OpenStudio::Time.new(0, 24, 0, 0) - start_hoo_time = OpenStudio::Time.new(0, start_hoo_hours, start_hoo_minutes, 0) - finish_hoo_time = OpenStudio::Time.new(0, finish_hoo_hours, finish_hoo_minutes, 0) - delta_time = OpenStudio::Time.new(0, delta_hours, delta_minutes, 0) # not used - shift_time = OpenStudio::Time.new(0, shift_hours, shift_minutes, 0) - - # calculations - if options['base_start_hoo'] <= options['base_finish_hoo'] - base_opp_day_length = options['base_finish_hoo'] - options['base_start_hoo'] - mid_hoo = start_hoo_time + (finish_hoo_time - start_hoo_time) / 2 - mid_non_hoo = mid_hoo + time_12 - if mid_non_hoo > time_24 then mid_non_hoo -= time_24 end - else - base_opp_day_length = options['base_finish_hoo'] - options['base_start_hoo'] + 24 - mid_non_hoo = finish_hoo_time + (start_hoo_time - finish_hoo_time) / 2 - mid_hoo = mid_non_hoo + time_12 - if mid_non_hoo > time_24 then mid_non_hoo -= time_24 end - end - adjusted_opp_day_length = base_opp_day_length + options['delta_length_hoo'] - hoo_time_multiplier = adjusted_opp_day_length / base_opp_day_length - non_hoo_time_multiplier = (24 - adjusted_opp_day_length) / (24 - base_opp_day_length) - - # check for invalid input - if adjusted_opp_day_length < 0 - OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.Schedules.Modify', 'Requested hours of operation adjustment results in an invalid negative hours of operation') - return false - end - # check for invalid input - if adjusted_opp_day_length > 24 - OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.Schedules.Modify', 'Requested hours of operation adjustment results in more than 24 hours of operation') - return false + return schedule_ruleset + end + + # Adjust hours of operation + # + # @param schedule_ruleset [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object + # @param options [Hash] Hash of argument options + # @return [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object + def self.schedule_ruleset_adjust_hours_of_operation(schedule_ruleset, options = {}) + defaults = { + 'base_start_hoo' => 8.0, # may not be good idea to have default + 'base_finish_hoo' => 18.0, # may not be good idea to have default + 'delta_length_hoo' => 0.0, + 'shift_hoo' => 0.0, + 'default' => true, + 'mon' => true, + 'tue' => true, + 'wed' => true, + 'thur' => true, + 'fri' => true, + 'sat' => true, + 'sun' => true, + 'summer' => false, + 'winter' => false + } + + # merge user inputs with defaults + options = defaults.merge(options) + + # grab schedule out of argument + if schedule_ruleset.to_ScheduleRuleset.is_initialized + schedule = schedule_ruleset.to_ScheduleRuleset.get + else + OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.Schedules.Modify', "schedule_ruleset_adjust_hours_of_operation only applies to ScheduleRuleset objects. Skipping #{schedule.name}") + return nil + end + + # array of all profiles to change + profiles = [] + + # push default profiles to array + if options['default'] + default_rule = schedule.defaultDaySchedule + profiles << default_rule + end + + # push profiles to array + rules = schedule.scheduleRules + rules.each do |rule| + day_sch = rule.daySchedule + + # if any day requested also exists in the rule, then it will be altered + alter_rule = false + if rule.applyMonday && rule.applyMonday == options['mon'] then alter_rule = true end + if rule.applyTuesday && rule.applyTuesday == options['tue'] then alter_rule = true end + if rule.applyWednesday && rule.applyWednesday == options['wed'] then alter_rule = true end + if rule.applyThursday && rule.applyThursday == options['thur'] then alter_rule = true end + if rule.applyFriday && rule.applyFriday == options['fri'] then alter_rule = true end + if rule.applySaturday && rule.applySaturday == options['sat'] then alter_rule = true end + if rule.applySunday && rule.applySunday == options['sun'] then alter_rule = true end + + # TODO: - add in logic to warn user about conflicts where a single rule has conflicting tests + + if alter_rule + profiles << day_sch end - - # making some temp objects to avoid having to deal with wrap around for change of hoo times - mid_hoo < start_hoo_time ? (adj_mid_hoo = mid_hoo + time_24) : (adj_mid_hoo = mid_hoo) - finish_hoo_time < adj_mid_hoo ? (adj_finish_hoo_time = finish_hoo_time + time_24) : (adj_finish_hoo_time = finish_hoo_time) - mid_non_hoo < adj_finish_hoo_time ? (adj_mid_non_hoo = mid_non_hoo + time_24) : (adj_mid_non_hoo = mid_non_hoo) - adj_start = start_hoo_time + time_24 # not used - - # edit profiles - profiles.each do |day_sch| - times = day_sch.times - values = day_sch.values - - # in this case delete all values outside of - # todo - may need similar logic if exactly 0 hours - if adjusted_opp_day_length == 24 - start_val = day_sch.getValue(start_hoo_time) - finish_val = day_sch.getValue(finish_hoo_time) - - # remove times out of range that should not be reference or compressed - if start_hoo_time < finish_hoo_time - times.each do |time| - if time <= start_hoo_time || time > finish_hoo_time - day_sch.removeValue(time) - end + end + + # add design days to array + if options['summer'] + summer_design = schedule.summerDesignDaySchedule + profiles << summer_design + end + if options['winter'] + winter_design = schedule.winterDesignDaySchedule + profiles << winter_design + end + + # give info messages as I change specific profiles + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.Schedules.Modify', "Adjusting #{schedule.name}") + + # rename schedule + schedule.setName("#{schedule.name} - extend #{options['delta_length_hoo']} shift #{options['shift_hoo']}") + + # break time args into hours and minutes + start_hoo_hours = (options['base_start_hoo']).to_i + start_hoo_minutes = (((options['base_start_hoo']) - (options['base_start_hoo']).to_i) * 60).to_i + finish_hoo_hours = (options['base_finish_hoo']).to_i + finish_hoo_minutes = (((options['base_finish_hoo']) - (options['base_finish_hoo']).to_i) * 60).to_i + delta_hours = (options['delta_length_hoo']).to_i + delta_minutes = (((options['delta_length_hoo']) - (options['delta_length_hoo']).to_i) * 60).to_i + shift_hours = (options['shift_hoo']).to_i + shift_minutes = (((options['shift_hoo']) - (options['shift_hoo']).to_i) * 60).to_i + + # time objects to use in measure + time_0 = OpenStudio::Time.new(0, 0, 0, 0) + time_1_min = OpenStudio::Time.new(0, 0, 1, 0) # add this to avoid times in day profile less than this + time_12 = OpenStudio::Time.new(0, 12, 0, 0) + time_24 = OpenStudio::Time.new(0, 24, 0, 0) + start_hoo_time = OpenStudio::Time.new(0, start_hoo_hours, start_hoo_minutes, 0) + finish_hoo_time = OpenStudio::Time.new(0, finish_hoo_hours, finish_hoo_minutes, 0) + delta_time = OpenStudio::Time.new(0, delta_hours, delta_minutes, 0) # not used + shift_time = OpenStudio::Time.new(0, shift_hours, shift_minutes, 0) + + # calculations + if options['base_start_hoo'] <= options['base_finish_hoo'] + base_opp_day_length = options['base_finish_hoo'] - options['base_start_hoo'] + mid_hoo = start_hoo_time + (finish_hoo_time - start_hoo_time) / 2 + mid_non_hoo = mid_hoo + time_12 + if mid_non_hoo > time_24 then mid_non_hoo -= time_24 end + else + base_opp_day_length = options['base_finish_hoo'] - options['base_start_hoo'] + 24 + mid_non_hoo = finish_hoo_time + (start_hoo_time - finish_hoo_time) / 2 + mid_hoo = mid_non_hoo + time_12 + if mid_non_hoo > time_24 then mid_non_hoo -= time_24 end + end + adjusted_opp_day_length = base_opp_day_length + options['delta_length_hoo'] + hoo_time_multiplier = adjusted_opp_day_length / base_opp_day_length + non_hoo_time_multiplier = (24 - adjusted_opp_day_length) / (24 - base_opp_day_length) + + # check for invalid input + if adjusted_opp_day_length < 0 + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.Schedules.Modify', 'Requested hours of operation adjustment results in an invalid negative hours of operation') + return false + end + # check for invalid input + if adjusted_opp_day_length > 24 + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.Schedules.Modify', 'Requested hours of operation adjustment results in more than 24 hours of operation') + return false + end + + # making some temp objects to avoid having to deal with wrap around for change of hoo times + mid_hoo < start_hoo_time ? (adj_mid_hoo = mid_hoo + time_24) : (adj_mid_hoo = mid_hoo) + finish_hoo_time < adj_mid_hoo ? (adj_finish_hoo_time = finish_hoo_time + time_24) : (adj_finish_hoo_time = finish_hoo_time) + mid_non_hoo < adj_finish_hoo_time ? (adj_mid_non_hoo = mid_non_hoo + time_24) : (adj_mid_non_hoo = mid_non_hoo) + adj_start = start_hoo_time + time_24 # not used + + # edit profiles + profiles.each do |day_sch| + times = day_sch.times + values = day_sch.values + + # in this case delete all values outside of + # todo - may need similar logic if exactly 0 hours + if adjusted_opp_day_length == 24 + start_val = day_sch.getValue(start_hoo_time) + finish_val = day_sch.getValue(finish_hoo_time) + + # remove times out of range that should not be reference or compressed + if start_hoo_time < finish_hoo_time + times.each do |time| + if time <= start_hoo_time || time > finish_hoo_time + day_sch.removeValue(time) end - # add in values - day_sch.addValue(start_hoo_time,start_val) - day_sch.addValue(finish_hoo_time,finish_val) - day_sch.addValue(time_24,[start_val,finish_val].max) - else - times.each do |time| - if time > start_hoo_time && time <= finish_hoo_time - day_sch.removeValue(time) - end + end + # add in values + day_sch.addValue(start_hoo_time,start_val) + day_sch.addValue(finish_hoo_time,finish_val) + day_sch.addValue(time_24,[start_val,finish_val].max) + else + times.each do |time| + if time > start_hoo_time && time <= finish_hoo_time + day_sch.removeValue(time) end - # add in values - day_sch.addValue(finish_hoo_time,finish_val) - day_sch.addValue(start_hoo_time,start_val) - day_sch.addValue(time_24,[values.first,values.last].max) end - + # add in values + day_sch.addValue(finish_hoo_time,finish_val) + day_sch.addValue(start_hoo_time,start_val) + day_sch.addValue(time_24,[values.first,values.last].max) end - - times = day_sch.times - values = day_sch.values - - # arrays for values to avoid overlap conflict of times - new_times = [] - new_values = [] - - # this is to store what datapoint will be first after midnight, and what the value at that time should be - min_time_new = time_24 - min_time_value = nil - - # flag if found time at 24 - found_24_or_0 = false - - # push times to array - times.each do |time| - # create logic for four possible quadrants. Assume any quadrant can pass over 24/0 threshold - time < start_hoo_time ? (temp_time = time + time_24) : (temp_time = time) - - # calculate change in time do to hoo delta - if temp_time <= adj_finish_hoo_time - expand_time = (temp_time - adj_mid_hoo) * hoo_time_multiplier - (temp_time - adj_mid_hoo) - else - expand_time = (temp_time - adj_mid_non_hoo) * non_hoo_time_multiplier - (temp_time - adj_mid_non_hoo) - end - - new_time = time + shift_time + expand_time - - # adjust wrap around times - if new_time < time_0 - new_time += time_24 - elsif new_time > time_24 - new_time -= time_24 - end - new_times << new_time - - # see which new_time has the lowest value. Then add a value at 24 equal to that - if !found_24_or_0 && new_time <= min_time_new - min_time_new = new_time - min_time_value = day_sch.getValue(time) - elsif new_time == time_24 # this was added to address time exactly at 24 - min_time_new = new_time - min_time_value = day_sch.getValue(time) - found_24_or_0 = true - elsif new_time == time_0 - min_time_new = new_time - min_time_value = day_sch.getValue(time_0) - found_24_or_0 = true - end + + end + + times = day_sch.times + values = day_sch.values + + # arrays for values to avoid overlap conflict of times + new_times = [] + new_values = [] + + # this is to store what datapoint will be first after midnight, and what the value at that time should be + min_time_new = time_24 + min_time_value = nil + + # flag if found time at 24 + found_24_or_0 = false + + # push times to array + times.each do |time| + # create logic for four possible quadrants. Assume any quadrant can pass over 24/0 threshold + time < start_hoo_time ? (temp_time = time + time_24) : (temp_time = time) + + # calculate change in time do to hoo delta + if temp_time <= adj_finish_hoo_time + expand_time = (temp_time - adj_mid_hoo) * hoo_time_multiplier - (temp_time - adj_mid_hoo) + else + expand_time = (temp_time - adj_mid_non_hoo) * non_hoo_time_multiplier - (temp_time - adj_mid_non_hoo) end - - # push values to array - values.each do |value| - new_values << value + + new_time = time + shift_time + expand_time + + # adjust wrap around times + if new_time < time_0 + new_time += time_24 + elsif new_time > time_24 + new_time -= time_24 end - - # add value for what will be 24 - new_times << time_24 - new_values << min_time_value - - new_time_val_hash = {} - new_times.each_with_index do |time,i| - new_time_val_hash[time.totalHours] = {:time => time, :value => new_values[i]} + new_times << new_time + + # see which new_time has the lowest value. Then add a value at 24 equal to that + if !found_24_or_0 && new_time <= min_time_new + min_time_new = new_time + min_time_value = day_sch.getValue(time) + elsif new_time == time_24 # this was added to address time exactly at 24 + min_time_new = new_time + min_time_value = day_sch.getValue(time) + found_24_or_0 = true + elsif new_time == time_0 + min_time_new = new_time + min_time_value = day_sch.getValue(time_0) + found_24_or_0 = true end - - # clear values - day_sch.clearValues - - new_time_val_hash = Hash[new_time_val_hash.sort] - prev_time = nil - new_time_val_hash.sort.each do |hours,time_val| - if prev_time.nil? || time_val[:time] - prev_time > time_1_min - day_sch.addValue(time_val[:time], time_val[:value]) - prev_time = time_val[:time] - else - OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.Schedules.Modify', "Time step in #{day_sch.name} between #{prev_time.toString} and #{time_val[:time].toString} is too small to support, not adding value.") - end + end + + # push values to array + values.each do |value| + new_values << value + end + + # add value for what will be 24 + new_times << time_24 + new_values << min_time_value + + new_time_val_hash = {} + new_times.each_with_index do |time,i| + new_time_val_hash[time.totalHours] = {:time => time, :value => new_values[i]} + end + + # clear values + day_sch.clearValues + + new_time_val_hash = Hash[new_time_val_hash.sort] + prev_time = nil + new_time_val_hash.sort.each do |hours,time_val| + if prev_time.nil? || time_val[:time] - prev_time > time_1_min + day_sch.addValue(time_val[:time], time_val[:value]) + prev_time = time_val[:time] + else + OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.Schedules.Modify', "Time step in #{day_sch.name} between #{prev_time.toString} and #{time_val[:time].toString} is too small to support, not adding value.") end - end - - return schedule + end + + return schedule end end end \ No newline at end of file diff --git a/test/schedules/test_schedules_create.rb b/test/schedules/test_schedules_create.rb index dccfecff80..28a931dba8 100644 --- a/test/schedules/test_schedules_create.rb +++ b/test/schedules/test_schedules_create.rb @@ -1,9 +1,10 @@ require_relative '../helpers/minitest_helper' -require_relative '../../lib/openstudio-standards/schedules/create' class TestSchedulesCreate < Minitest::Test - include OpenstudioStandards::Schedules::Create - + def setup + @sch = OpenstudioStandards::Schedules + end + def test_model_create_simple_schedule model = OpenStudio::Model::Model.new test_options = { @@ -12,7 +13,7 @@ def test_model_create_simple_schedule 'summerTimeValuePairs' => { 8.0 => 0.0, 16.0 => 1.0, 24.0 => 0.0 }, 'defaultTimeValuePairs' => { 8.0 => 0.0, 16.0 => 1.0, 24.0 => 0.0 } } - schedule = model_create_simple_schedule(model, test_options) + schedule = @sch.model_create_simple_schedule(model, test_options) assert(schedule.to_ScheduleRuleset.is_initialized) assert(schedule.name.to_s == 'Test Create Simple') end @@ -28,7 +29,7 @@ def test_model_create_complex_schedule 'default_day' => ['Test Create Complex Default', [11, 0], [11.33, 1], [23, 0], [23.33, 1], [24, 0]], 'rules' => rules } - schedule = model_create_complex_schedule(model, test_options) + schedule = @sch.model_create_complex_schedule(model, test_options) assert(schedule.to_ScheduleRuleset.is_initialized) assert(schedule.name.to_s == 'Test Create Complex') end @@ -39,8 +40,8 @@ def test_model_create_schedule_from_rate_of_change 'name' => 'Test Create Rate Of Change', 'defaultTimeValuePairs' => { 4.0 => 0.0, 6.0 => 6.0, 8.0 => 15.0, 16 => 7.0, 24 => 0.0 } } - input_schedule = model_create_simple_schedule(model, test_options) - output_schedule = model_create_schedule_from_rate_of_change(model, input_schedule) + input_schedule = @sch.model_create_simple_schedule(model, test_options) + output_schedule = @sch.model_create_schedule_from_rate_of_change(model, input_schedule) assert(output_schedule.to_ScheduleRuleset.is_initialized) end @@ -50,19 +51,19 @@ def test_model_create_weighted_merge_schedules 'name' => 'Schedule1', 'defaultTimeValuePairs' => { 8.0 => 0.0, 16.0 => 10.0, 24.0 => 0.0 } } - schedule1 = model_create_simple_schedule(model, schedule1_options) + schedule1 = @sch.model_create_simple_schedule(model, schedule1_options) schedule2_options = { 'name' => 'Schedule2', 'defaultTimeValuePairs' => { 8.0 => 0.0, 16.0 => 20.0, 24.0 => 0.0 } } - schedule2 = model_create_simple_schedule(model, schedule2_options) + schedule2 = @sch.model_create_simple_schedule(model, schedule2_options) schedule_weights_hash = {} schedule_weights_hash[schedule1] = 2 schedule_weights_hash[schedule2] = 8 - schedule = model_create_weighted_merge_schedules(model, schedule_weights_hash) + schedule = @sch.model_create_weighted_merge_schedules(model, schedule_weights_hash) assert(schedule['mergedSchedule'].to_ScheduleRuleset.is_initialized) assert(schedule['mergedSchedule'].name.to_s == 'Merged Schedule') assert(schedule['denominator'] == 10.0) diff --git a/test/schedules/test_schedules_information.rb b/test/schedules/test_schedules_information.rb index c27d134b3f..f20e0f9b32 100644 --- a/test/schedules/test_schedules_information.rb +++ b/test/schedules/test_schedules_information.rb @@ -1,10 +1,9 @@ require_relative '../helpers/minitest_helper' -require_relative '../../lib/openstudio-standards/schedules/create' -require_relative '../../lib/openstudio-standards/schedules/information' class TestSchedulesModify < Minitest::Test - include OpenstudioStandards::Schedules::Create - include OpenstudioStandards::Schedules::Information + def setup + @sch = OpenstudioStandards::Schedules + end def test_schedule_ruleset_min_max model = OpenStudio::Model::Model.new @@ -14,8 +13,8 @@ def test_schedule_ruleset_min_max 'summerTimeValuePairs' => { 8.0 => 2.0, 16.0 => 10.0, 24.0 => 3.0 }, 'defaultTimeValuePairs' => { 8.0 => 6.0, 16.0 => 14.0, 24.0 => 7.0 } } - schedule = model_create_simple_schedule(model, test_options) - result = schedule_ruleset_min_max(schedule) + schedule = @sch.model_create_simple_schedule(model, test_options) + result = @sch.schedule_ruleset_min_max(schedule) assert(result['min'] == 6.0) assert(result['max'] == 14.0) end @@ -28,8 +27,8 @@ def test_schedule_ruleset_timeseries 'summerTimeValuePairs' => { 8.0 => 2.0, 16.0 => 10.0, 24.0 => 3.0 }, 'defaultTimeValuePairs' => { 8.0 => 6.0, 16.0 => 14.0, 24.0 => 7.0 } } - schedule = model_create_simple_schedule(model, test_options) - result = schedule_ruleset_timeseries(schedule) + schedule = @sch.model_create_simple_schedule(model, test_options) + result = @sch.schedule_ruleset_timeseries(schedule) assert(result.class.to_s == 'OpenStudio::TimeSeries') assert(result.values.length == (8760*2 - 365)) end diff --git a/test/schedules/test_schedules_modify.rb b/test/schedules/test_schedules_modify.rb index 5deb18be5b..b0671826f7 100644 --- a/test/schedules/test_schedules_modify.rb +++ b/test/schedules/test_schedules_modify.rb @@ -1,12 +1,9 @@ require_relative '../helpers/minitest_helper' -require_relative '../../lib/openstudio-standards/schedules/create' -require_relative '../../lib/openstudio-standards/schedules/modify' -require_relative '../../lib/openstudio-standards/schedules/information' class TestSchedulesModify < Minitest::Test - include OpenstudioStandards::Schedules::Create - include OpenstudioStandards::Schedules::Modify - include OpenstudioStandards::Schedules::Information + def setup + @sch = OpenstudioStandards::Schedules + end def test_schedule_ruleset_simple_value_adjust model = OpenStudio::Model::Model.new @@ -14,15 +11,15 @@ def test_schedule_ruleset_simple_value_adjust 'name' => 'Simple Schedule', 'defaultTimeValuePairs' => { 8.0 => 0.0, 16.0 => 3.0, 24.0 => 0.0 } } - schedule = model_create_simple_schedule(model, test_options) - schedule_ruleset_simple_value_adjust(schedule, 0.5) + schedule = @sch.model_create_simple_schedule(model, test_options) + @sch.schedule_ruleset_simple_value_adjust(schedule, 0.5) assert(schedule.to_ScheduleRuleset.is_initialized) - schedule_max = schedule_ruleset_min_max(schedule)['max'] + schedule_max = @sch.schedule_ruleset_min_max(schedule)['max'] assert(schedule_max == 1.5) - schedule_ruleset_simple_value_adjust(schedule, 0.5, 'Sum') + @sch.schedule_ruleset_simple_value_adjust(schedule, 0.5, 'Sum') assert(schedule.to_ScheduleRuleset.is_initialized) - schedule_max = schedule_ruleset_min_max(schedule)['max'] + schedule_max = @sch.schedule_ruleset_min_max(schedule)['max'] assert(schedule_max == 2.0) end @@ -32,13 +29,13 @@ def test_schedule_ruleset_conditional_adjust_value 'name' => 'Simple Schedule', 'defaultTimeValuePairs' => { 8.0 => 0.0, 12 => 2.0, 16.0 => 4.0, 24.0 => 0.0 } } - schedule = model_create_simple_schedule(model, test_options) + schedule = @sch.model_create_simple_schedule(model, test_options) test_value = 3.0 pass_value = 1.5 fail_value = 2.0 floor_value = 0.1 - schedule_ruleset_conditional_adjust_value(schedule, test_value, pass_value, fail_value, floor_value) - schedule_max = schedule_ruleset_min_max(schedule)['max'] + @sch.schedule_ruleset_conditional_adjust_value(schedule, test_value, pass_value, fail_value, floor_value) + schedule_max = @sch.schedule_ruleset_min_max(schedule)['max'] assert(schedule_max == 8.0) end @@ -48,12 +45,12 @@ def test_schedule_ruleset_time_conditional_adjust_value 'name' => 'Simple Schedule', 'defaultTimeValuePairs' => { 8.0 => 0.0, 16.0 => 3.0, 24.0 => 0.0 } } - schedule = model_create_simple_schedule(model, test_options) + schedule = @sch.model_create_simple_schedule(model, test_options) hhmm_before = 1400 hhmm_after = 2030 inside_value = 2.0 outside_value = 1.0 - schedule_ruleset_time_conditional_adjust_value(schedule, hhmm_before, hhmm_after, inside_value, outside_value) + @sch.schedule_ruleset_time_conditional_adjust_value(schedule, hhmm_before, hhmm_after, inside_value, outside_value) end def test_schedule_ruleset_adjust_hours_of_operation @@ -62,9 +59,8 @@ def test_schedule_ruleset_adjust_hours_of_operation 'name' => 'Simple Schedule', 'defaultTimeValuePairs' => { 8.0 => 0.0, 16.0 => 3.0, 24.0 => 0.0 } } - schedule = model_create_simple_schedule(model, test_options) + schedule = @sch.model_create_simple_schedule(model, test_options) basic_shift = { 'shift_hoo' => 2.0 } - schedule_ruleset_adjust_hours_of_operation(schedule, basic_shift) - model.save('test_schedule_ruleset_adjust_hours_of_operation.osm') + @sch.schedule_ruleset_adjust_hours_of_operation(schedule, basic_shift) end end \ No newline at end of file From 671295b7aa5383826e9691282888cf6ae6f60b78 Mon Sep 17 00:00:00 2001 From: Matthew Dahlhausen Date: Tue, 12 Sep 2023 14:40:05 -0600 Subject: [PATCH 36/45] fix yard documentation --- lib/openstudio-standards/schedules/create.rb | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/lib/openstudio-standards/schedules/create.rb b/lib/openstudio-standards/schedules/create.rb index caf98ce525..34edb1981a 100644 --- a/lib/openstudio-standards/schedules/create.rb +++ b/lib/openstudio-standards/schedules/create.rb @@ -153,7 +153,7 @@ def self.model_create_complex_schedule(model, options = {}) # create a new schedule using absolute velocity of existing schedule # # @param model [OpenStudio::Model::Model] OpenStudio model object - # @param schedule [OpenStudio::Model::ScheduleRuleset] OpenStudio ruleset schedule object + # @param schedule_ruleset [OpenStudio::Model::ScheduleRuleset] OpenStudio ruleset schedule object # @return [OpenStudio::Model::ScheduleRuleset] OpenStudio ScheduleRuleset object # @todo fix velocity so it isn't fraction change per step, but per hour # (I need to count hours between times and divide value by this) @@ -237,7 +237,7 @@ def self.model_create_schedule_from_rate_of_change(model, schedule_ruleset) # # @param model [OpenStudio::Model::Model] OpenStudio model object # @param schedule_weights_hash [Hash] Array of hashes of {OpenStudio::Model::ScheduleRuleset, Double} - # @sch_name [String] Optional name of new schedule + # @param sch_name [String] Optional name of new schedule # @return [Hash] Hash of {OpenStudio::Model::ScheduleRuleset, Double} # with the OpenStudio ScheduleRuleset object and the total denominator # @todo apply weights to schedule rules as well, not just winter, summer, and default profile From 7049071957aba105bda913030d8d98594a74e94e Mon Sep 17 00:00:00 2001 From: Matthew Dahlhausen Date: Tue, 12 Sep 2023 23:07:39 -0600 Subject: [PATCH 37/45] add OsLib_ModelGeneration methods --- .yardopts | 5 +- lib/openstudio-standards.rb | 12 + .../create_typical/create_typical.rb | 932 +++++++++ .../create_typical/enumerations.rb | 289 +++ .../create_typical/space_type_ratios.rb | 474 +++++ lib/openstudio-standards/geometry/create.rb | 1855 +++++++++++++++++ .../geometry/information.rb | 19 + lib/openstudio-standards/geometry/modify.rb | 7 + test/create_typical/test_create_typical.rb | 15 + test/create_typical/test_enumerations.rb | 102 + test/create_typical/test_space_type_ratios.rb | 22 + 11 files changed, 3731 insertions(+), 1 deletion(-) create mode 100644 lib/openstudio-standards/create_typical/create_typical.rb create mode 100644 lib/openstudio-standards/create_typical/enumerations.rb create mode 100644 lib/openstudio-standards/create_typical/space_type_ratios.rb create mode 100644 lib/openstudio-standards/geometry/create.rb create mode 100644 lib/openstudio-standards/geometry/information.rb create mode 100644 lib/openstudio-standards/geometry/modify.rb create mode 100644 test/create_typical/test_create_typical.rb create mode 100644 test/create_typical/test_enumerations.rb create mode 100644 test/create_typical/test_space_type_ratios.rb diff --git a/.yardopts b/.yardopts index 083b205779..6f0edac4c8 100644 --- a/.yardopts +++ b/.yardopts @@ -16,7 +16,10 @@ lib/openstudio-standards/prototypes/**/*.rb lib/openstudio-standards/utilities/**/*.rb lib/openstudio-standards/weather/**/*.rb lib/openstudio-standards/refs/references.rb -lib/openstudio-standards/schedules/*.rb +lib/openstudio-standards/schedules/**/*.rb +lib/openstudio-standards/geometry/**/*.rb +lib/openstudio-standards/create_typical/**/*.rb + - docs/Home.md docs/UserQuickStartGuide.md diff --git a/lib/openstudio-standards.rb b/lib/openstudio-standards.rb index e796957cce..612b743c33 100644 --- a/lib/openstudio-standards.rb +++ b/lib/openstudio-standards.rb @@ -6,10 +6,22 @@ module OpenstudioStandards require 'json' # Used to load standards JSON files # Load Modules + + # Geometry Module + require_relative 'openstudio-standards/geometry/create' + require_relative 'openstudio-standards/geometry/modify' + require_relative 'openstudio-standards/geometry/information' + + # Schedules Module require_relative 'openstudio-standards/schedules/create' require_relative 'openstudio-standards/schedules/modify' require_relative 'openstudio-standards/schedules/information' + # CreateTypical Module + require_relative 'openstudio-standards/create_typical/enumerations' + require_relative 'openstudio-standards/create_typical/space_type_ratios' + require_relative 'openstudio-standards/create_typical/create_typical' + # Weather data require_relative 'openstudio-standards/weather/Weather.Model' diff --git a/lib/openstudio-standards/create_typical/create_typical.rb b/lib/openstudio-standards/create_typical/create_typical.rb new file mode 100644 index 0000000000..994f618edc --- /dev/null +++ b/lib/openstudio-standards/create_typical/create_typical.rb @@ -0,0 +1,932 @@ +# Methods to create typical models +module OpenstudioStandards + module CreateTypical + # @!group CreateTypical + + # create typical building from model + # creates a complete energy model from model with defined geometry and standards space type assignments + # + # @return [Boolean] returns true if successful, false if not + def self.typical_building_from_model(model, runner, user_arguments) + # assign the user inputs to variables + args = OsLib_HelperMethods.createRunVariables(runner, model, user_arguments, arguments(model)) + if !args then return false end + + # lookup and replace argument values from upstream measures + if args['use_upstream_args'] == true + args.each do |arg, value| + next if arg == 'use_upstream_args' # this argument should not be changed + value_from_osw = OsLib_HelperMethods.check_upstream_measure_for_arg(runner, arg) + if !value_from_osw.empty? + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Replacing argument named #{arg} from current measure with a value of #{value_from_osw[:value]} from #{value_from_osw[:measure_name]}.") + new_val = value_from_osw[:value] + # TODO: - make code to handle non strings more robust. check_upstream_measure_for_arg coudl pass bakc the argument type + if arg == 'total_bldg_floor_area' + args[arg] = new_val.to_f + elsif arg == 'num_stories_above_grade' + args[arg] = new_val.to_f + elsif arg == 'zipcode' + args[arg] = new_val.to_i + else + args[arg] = new_val + end + end + end + end + + # validate fraction parking + fraction = OsLib_HelperMethods.checkDoubleAndIntegerArguments(runner, user_arguments, 'min' => 0.0, 'max' => 1.0, 'min_eq_bool' => true, 'max_eq_bool' => true, 'arg_array' => ['onsite_parking_fraction']) + if !fraction then return false end + + # validate unmet hours tolerance + unmet_hours_tolerance_valid = OsLib_HelperMethods.checkDoubleAndIntegerArguments(runner, user_arguments, 'min' => 0.0, 'max' => 5.0, 'min_eq_bool' => true, 'max_eq_bool' => true, 'arg_array' => ['unmet_hours_tolerance']) + if !unmet_hours_tolerance_valid then return false end + + # validate weekday hours of operation + wkdy_op_hrs_start_time_hr = nil + wkdy_op_hrs_start_time_min = nil + wkdy_op_hrs_duration_hr = nil + wkdy_op_hrs_duration_min = nil + if args['modify_wkdy_op_hrs'] + # weekday start time hr + wkdy_op_hrs_start_time_hr = args['wkdy_op_hrs_start_time'].floor + if wkdy_op_hrs_start_time_hr < 0 || wkdy_op_hrs_start_time_hr > 24 + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Weekday operating hours start time hrs must be between 0 and 24. #{args['wkdy_op_hrs_start_time']} was entered.") + return false + end + + # weekday start time min + wkdy_op_hrs_start_time_min = (60.0 * (args['wkdy_op_hrs_start_time'] - args['wkdy_op_hrs_start_time'].floor)).floor + if wkdy_op_hrs_start_time_min < 0 || wkdy_op_hrs_start_time_min > 59 + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Weekday operating hours start time mins must be between 0 and 59. #{args['wkdy_op_hrs_start_time']} was entered.") + return false + end + + # weekday duration hr + wkdy_op_hrs_duration_hr = args['wkdy_op_hrs_duration'].floor + if wkdy_op_hrs_duration_hr < 0 || wkdy_op_hrs_duration_hr > 24 + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Weekday operating hours duration hrs must be between 0 and 24. #{args['wkdy_op_hrs_duration']} was entered.") + return false + end + + # weekday duration min + wkdy_op_hrs_duration_min = (60.0 * (args['wkdy_op_hrs_duration'] - args['wkdy_op_hrs_duration'].floor)).floor + if wkdy_op_hrs_duration_min < 0 || wkdy_op_hrs_duration_min > 59 + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Weekday operating hours duration mins must be between 0 and 59. #{args['wkdy_op_hrs_duration']} was entered.") + return false + end + + # check that weekday start time plus duration does not exceed 24 hrs + if (wkdy_op_hrs_start_time_hr + wkdy_op_hrs_duration_hr + (wkdy_op_hrs_start_time_min + wkdy_op_hrs_duration_min) / 60.0) > 24.0 + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Weekday start time of #{args['wkdy_op_hrs_start']} plus duration of #{args['wkdy_op_hrs_duration']} is more than 24 hrs, hours of operation overlap midnight.") + end + end + + # validate weekend hours of operation + wknd_op_hrs_start_time_hr = nil + wknd_op_hrs_start_time_min = nil + wknd_op_hrs_duration_hr = nil + wknd_op_hrs_duration_min = nil + if args['modify_wknd_op_hrs'] + # weekend start time hr + wknd_op_hrs_start_time_hr = args['wknd_op_hrs_start_time'].floor + if wknd_op_hrs_start_time_hr < 0 || wknd_op_hrs_start_time_hr > 24 + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Weekend operating hours start time hrs must be between 0 and 24. #{args['wknd_op_hrs_start_time_change']} was entered.") + return false + end + + # weekend start time min + wknd_op_hrs_start_time_min = (60.0 * (args['wknd_op_hrs_start_time'] - args['wknd_op_hrs_start_time'].floor)).floor + if wknd_op_hrs_start_time_min < 0 || wknd_op_hrs_start_time_min > 59 + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Weekend operating hours start time mins must be between 0 and 59. #{args['wknd_op_hrs_start_time_change']} was entered.") + return false + end + + # weekend duration hr + wknd_op_hrs_duration_hr = args['wknd_op_hrs_duration'].floor + if wknd_op_hrs_duration_hr < 0 || wknd_op_hrs_duration_hr > 24 + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Weekend operating hours duration hrs must be between 0 and 24. #{args['wknd_op_hrs_duration']} was entered.") + return false + end + + # weekend duration min + wknd_op_hrs_duration_min = (60.0 * (args['wknd_op_hrs_duration'] - args['wknd_op_hrs_duration'].floor)).floor + if wknd_op_hrs_duration_min < 0 || wknd_op_hrs_duration_min > 59 + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Weekend operating hours duration min smust be between 0 and 59. #{args['wknd_op_hrs_duration']} was entered.") + return false + end + + # check that weekend start time plus duration does not exceed 24 hrs + if (wknd_op_hrs_start_time_hr + wknd_op_hrs_duration_hr + (wknd_op_hrs_start_time_min + wknd_op_hrs_duration_min) / 60.0) > 24.0 + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Weekend start time of #{args['wknd_op_hrs_start']} plus duration of #{args['wknd_op_hrs_duration']} is more than 24 hrs, hours of operation overlap midnight.") + end + end + + # report initial condition of model + initial_objects = model.getModelObjects.size + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "The building started with #{initial_objects} objects.") + + # open channel to log messages + reset_log + + # Make the standard applier + standard = Standard.build((args['template']).to_s) + + # validate climate zone + if !args.key?('climate_zone') || args['climate_zone'] == 'Lookup From Model' + climate_zone = standard.model_get_building_properties(model)['climate_zone'] + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Using climate zone #{climate_zone} from model") + else + climate_zone = args['climate_zone'] + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Using climate zone #{climate_zone} from user arguments") + end + if climate_zone == '' + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Could not determine climate zone from measure arguments or model.") + return false + end + + # if haystack_file used find the file + # todo - may want to allow NA, empty string or some other value to skip so a measure can ake this optional witht using optional measure arguments + if args['haystack_file'] + haystack_file = runner.workflow.findFile(args['haystack_file']) + if haystack_file.is_initialized + haystack_file = haystack_file.get.to_s + + # load JSON file + json = nil + File.open(haystack_file, 'r') do |file| + json = file.read + # uncomment to inspect haystack json + # puts json + end + + else + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Did not find #{args['haystack_file']} in paths described in OSW file.") + return false + end + else + haystack_file = nil + end + + # make sure daylight savings is turned on up prior to any sizing runs being done. + if args['enable_dst'] + start_date = '2nd Sunday in March' + end_date = '1st Sunday in November' + + runperiodctrl_daylgtsaving = model.getRunPeriodControlDaylightSavingTime + runperiodctrl_daylgtsaving.setStartDate(start_date) + runperiodctrl_daylgtsaving.setEndDate(end_date) + end + + # add internal loads to space types + if args['add_space_type_loads'] + + # remove internal loads + if args['remove_objects'] + model.getSpaceLoads.sort.each do |instance| + next if instance.name.to_s.include?('Elevator') # most prototype building types model exterior elevators with name Elevator + next if instance.to_InternalMass.is_initialized + next if instance.to_WaterUseEquipment.is_initialized + instance.remove + end + model.getDesignSpecificationOutdoorAirs.each(&:remove) + model.getDefaultScheduleSets.each(&:remove) + end + + model.getSpaceTypes.sort.each do |space_type| + # Don't add infiltration here; will be added later in the script + test = standard.space_type_apply_internal_loads(space_type, true, true, true, true, true, false) + if test == false + OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.CreateTypical', "Could not add loads for #{space_type.name}. Not expected for #{args['template']}") + next + end + + # apply internal load schedules + # the last bool test it to make thermostat schedules. They are now added in HVAC section instead of here + standard.space_type_apply_internal_load_schedules(space_type, true, true, true, true, true, true, false) + + # extend space type name to include the args['template']. Consider this as well for load defs + space_type.setName("#{space_type.name} - #{args['template']}") + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Adding loads to space type named #{space_type.name}") + end + + # warn if spaces in model without space type + spaces_without_space_types = [] + model.getSpaces.sort.each do |space| + next if space.spaceType.is_initialized + spaces_without_space_types << space + end + if !spaces_without_space_types.empty? + OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.CreateTypical', "#{spaces_without_space_types.size} spaces do not have space types assigned, and wont' receive internal loads from standards space type lookups.") + end + end + + # identify primary building type (used for construction, and ideally HVAC as well) + building_types = {} + model.getSpaceTypes.sort.each do |space_type| + # populate hash of building types + if space_type.standardsBuildingType.is_initialized + bldg_type = space_type.standardsBuildingType.get + if !building_types.key?(bldg_type) + building_types[bldg_type] = space_type.floorArea + else + building_types[bldg_type] += space_type.floorArea + end + else + OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.CreateTypical', "Can't identify building type for #{space_type.name}") + end + end + primary_bldg_type = building_types.key(building_types.values.max) # TODO: - this fails if no space types, or maybe just no space types with standards + lookup_building_type = standard.model_get_lookup_name(primary_bldg_type) # Used for some lookups in the standards gem + model.getBuilding.setStandardsBuildingType(primary_bldg_type) + + # make construction set and apply to building + if args['add_constructions'] + + # remove default construction sets + if args['remove_objects'] + model.getDefaultConstructionSets.each(&:remove) + end + + # TODO: - allow building type and space type specific constructions set selection. + if ['SmallHotel', 'LargeHotel', 'MidriseApartment', 'HighriseApartment'].include?(primary_bldg_type) + is_residential = 'Yes' + occ_type = 'Residential' + else + is_residential = 'No' + occ_type = 'Nonresidential' + end + bldg_def_const_set = standard.model_add_construction_set(model, climate_zone, lookup_building_type, nil, is_residential) + if bldg_def_const_set.is_initialized + bldg_def_const_set = bldg_def_const_set.get + if is_residential then bldg_def_const_set.setName("Res #{bldg_def_const_set.name}") end + model.getBuilding.setDefaultConstructionSet(bldg_def_const_set) + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Adding default construction set named #{bldg_def_const_set.name}") + else + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Could not create default construction set for the building type #{lookup_building_type} in climate zone #{climate_zone}.") + log_messages_to_runner(runner, debug = true) + return false + end + + # Replace the construction of any outdoor-facing "AtticFloor" surfaces + # with the "ExteriorRoof" - "IEAD" construction for the specific climate zone and template. + # This prevents creation of buildings where the DOE Prototype building construction set + # assumes an attic but the supplied geometry used does not have an attic. + new_construction = nil + climate_zone_set = standard.model_find_climate_zone_set(model, climate_zone) + model.getSurfaces.sort.each do |surf| + next unless surf.outsideBoundaryCondition == 'Outdoors' + next unless surf.surfaceType == 'RoofCeiling' + next if surf.construction.empty? + construction = surf.construction.get + standards_info = construction.standardsInformation + next if standards_info.intendedSurfaceType.empty? + next unless standards_info.intendedSurfaceType.get == 'AtticFloor' + if new_construction.nil? + new_construction = standard.model_find_and_add_construction(model, + climate_zone_set, + 'ExteriorRoof', + 'IEAD', + occ_type) + end + surf.setConstruction(new_construction) + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Changed the construction for #{surf.name} from #{construction.name} to #{new_construction.name} to avoid outdoor-facing attic floor constructions in buildings with no attic space.") + end + + # address any adiabatic surfaces that don't have hard assigned constructions + model.getSurfaces.sort.each do |surface| + next if surface.outsideBoundaryCondition != 'Adiabatic' + next if surface.construction.is_initialized + surface.setAdjacentSurface(surface) + surface.setConstruction(surface.construction.get) + surface.setOutsideBoundaryCondition('Adiabatic') + end + + # modify the infiltration rates + if args['remove_objects'] + model.getSpaceInfiltrationDesignFlowRates.each(&:remove) + end + standard.model_apply_infiltration_standard(model) + standard.model_modify_infiltration_coefficients(model, primary_bldg_type, climate_zone) + + # set ground temperatures from DOE prototype buildings + standard.model_add_ground_temperatures(model, primary_bldg_type, climate_zone) + + end + + # add elevators (returns ElectricEquipment object) + if args['add_elevators'] + + # remove elevators as spaceLoads or exteriorLights + model.getSpaceLoads.sort.each do |instance| + next if !instance.name.to_s.include?('Elevator') # most prototype building types model exterior elevators with name Elevator + instance.remove + end + model.getExteriorLightss.sort.each do |ext_light| + next if !ext_light.name.to_s.include?('Fuel equipment') # some prototype building types model exterior elevators by this name + ext_light.remove + end + + elevators = standard.model_add_elevators(model) + if elevators.nil? + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', 'No elevators added to the building.') + else + elevator_def = elevators.electricEquipmentDefinition + design_level = elevator_def.designLevel.get + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Adding #{elevators.multiplier.round(1)} elevators each with power of #{OpenStudio.toNeatString(design_level, 0, true)} (W), plus lights and fans.") + elevator_def.setFractionLatent(0.0) + elevator_def.setFractionRadiant(0.0) + elevator_def.setFractionLost(1.0) + end + end + + # add exterior lights (returns a hash where key is lighting type and value is exteriorLights object) + if args['add_exterior_lights'] + + if args['remove_objects'] + model.getExteriorLightss.sort.each do |ext_light| + next if ext_light.name.to_s.include?('Fuel equipment') # some prototype building types model exterior elevators by this name + ext_light.remove + end + end + + exterior_lights = standard.model_add_typical_exterior_lights(model, args['exterior_lighting_zone'].chars[0].to_i, args['onsite_parking_fraction']) + exterior_lights.each do |k, v| + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Adding Exterior Lights named #{v.exteriorLightsDefinition.name} with design level of #{v.exteriorLightsDefinition.designLevel} * #{OpenStudio.toNeatString(v.multiplier, 0, true)}.") + end + end + + # add_exhaust + if args['add_exhaust'] + + # remove exhaust objects + if args['remove_objects'] + model.getFanZoneExhausts.each(&:remove) + end + + zone_exhaust_fans = standard.model_add_exhaust(model, args['kitchen_makeup']) # second argument is strategy for finding makeup zones for exhaust zones + zone_exhaust_fans.each do |k, v| + max_flow_rate_ip = OpenStudio.convert(k.maximumFlowRate.get, 'm^3/s', 'cfm').get + if v.key?(:zone_mixing) + zone_mixing = v[:zone_mixing] + mixing_source_zone_name = zone_mixing.sourceZone.get.name + mixing_design_flow_rate_ip = OpenStudio.convert(zone_mixing.designFlowRate.get, 'm^3/s', 'cfm').get + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Adding #{OpenStudio.toNeatString(max_flow_rate_ip, 0, true)} (cfm) of exhaust to #{k.thermalZone.get.name}, with #{OpenStudio.toNeatString(mixing_design_flow_rate_ip, 0, true)} (cfm) of makeup air from #{mixing_source_zone_name}") + else + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Adding #{OpenStudio.toNeatString(max_flow_rate_ip, 0, true)} (cfm) of exhaust to #{k.thermalZone.get.name}") + end + end + end + + # add service water heating demand and supply + if args['add_swh'] + + # remove water use equipment and water use connections + if args['remove_objects'] + # TODO: - remove plant loops used for service water heating + model.getWaterUseEquipments.each(&:remove) + model.getWaterUseConnectionss.each(&:remove) + end + + # Infer the SWH type + if args['swh_src'] == 'Inferred' + if args['htg_src'] == 'NaturalGas' || args['htg_src'] == 'DistrictHeating' + args['swh_src'] = 'NaturalGas' # If building has gas service, probably uses natural gas for SWH + elsif args['htg_src'] == 'Electricity' + args['swh_src'] = 'Electricity' # If building is doing space heating with electricity, probably used for SWH + elsif args['htg_src'] == 'DistrictAmbient' + args['swh_src'] = 'HeatPump' # If building has district ambient loop, it is fancy and probably uses HPs for SWH + else + args['swh_src'] = nil # Use inferences built into OpenStudio Standards for each building and space type + end + end + + typical_swh = standard.model_add_typical_swh(model, water_heater_fuel: args['swh_src']) + midrise_swh_loops = [] + stripmall_swh_loops = [] + typical_swh.each do |loop| + if loop.name.get.include?('MidriseApartment') + midrise_swh_loops << loop + elsif loop.name.get.include?('RetailStripmall') + stripmall_swh_loops << loop + else + water_use_connections = [] + loop.demandComponents.each do |component| + next if !component.to_WaterUseConnections.is_initialized + water_use_connections << component + end + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Adding #{loop.name} to the building. It has #{water_use_connections.size} water use connections.") + end + end + if !midrise_swh_loops.empty? + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Adding #{midrise_swh_loops.size} MidriseApartment service water heating loops.") + end + if !stripmall_swh_loops.empty? + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Adding #{stripmall_swh_loops.size} RetailStripmall service water heating loops.") + end + end + + # add_daylighting_controls (since outdated measure don't have this default to true if arg not found) + if !args.has_key?('add_daylighting_controls') + args['add_daylighting_controls'] = true + end + if args['add_daylighting_controls'] + # remove add_daylighting_controls objects + if args['remove_objects'] + model.getDaylightingControls.each(&:remove) + end + + # add daylight controls, need to perform a sizing run for 2010 + if args['template'] == '90.1-2010' || args['template'] == 'ComStock 90.1-2010' + if standard.model_run_sizing_run(model, "#{Dir.pwd}/SRvt") == false + log_messages_to_runner(runner, debug = true) + return false + end + end + standard.model_add_daylighting_controls(model) + end + + # add refrigeration + if args['add_refrigeration'] + + # remove refrigeration equipment + if args['remove_objects'] + model.getRefrigerationSystems.each(&:remove) + end + + # Add refrigerated cases and walkins + standard.model_add_typical_refrigeration(model, primary_bldg_type) + end + + # add internal mass + if args['add_internal_mass'] + + if args['remove_objects'] + model.getSpaceLoads.sort.each do |instance| + next unless instance.to_InternalMass.is_initialized + instance.remove + end + end + + # add internal mass to conditioned spaces; needs to happen after thermostats are applied + standard.model_add_internal_mass(model, primary_bldg_type) + end + + # TODO: - add slab modeling and slab insulation + + # TODO: - fuel customization for cooking and laundry + # works by switching some fraction of electric loads to gas if requested (assuming base load is electric) + + # add thermostats + if args['add_thermostat'] + + # remove thermostats + if args['remove_objects'] + model.getThermostatSetpointDualSetpoints.each(&:remove) + end + + model.getSpaceTypes.sort.each do |space_type| + # create thermostat schedules + # skip un-recognized space types + next if standard.space_type_get_standards_data(space_type).empty? + # the last bool test it to make thermostat schedules. They are added to the model but not assigned + standard.space_type_apply_internal_load_schedules(space_type, false, false, false, false, false, false, true) + + # identify thermal thermostat and apply to zones (apply_internal_load_schedules names ) + model.getThermostatSetpointDualSetpoints.sort.each do |thermostat| + next if thermostat.name.to_s != "#{space_type.name} Thermostat" + next if !thermostat.coolingSetpointTemperatureSchedule.is_initialized + next if !thermostat.heatingSetpointTemperatureSchedule.is_initialized + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Assigning #{thermostat.name} to thermal zones with #{space_type.name} assigned.") + space_type.spaces.sort.each do |space| + next if !space.thermalZone.is_initialized + space.thermalZone.get.setThermostatSetpointDualSetpoint(thermostat) + end + end + end + end + + # add hvac system + if args['add_hvac'] + + # remove HVAC objects + if args['remove_objects'] + standard.model_remove_prm_hvac(model) + end + + case args['system_type'] + when 'Inferred' + + # Get the hvac delivery type enum + hvac_delivery = case args['hvac_delivery_type'] + when 'Forced Air' + 'air' + when 'Hydronic' + 'hydronic' + end + + # Group the zones by occupancy type. Only split out non-dominant groups if their total area exceeds the limit. + sys_groups = standard.model_group_zones_by_type(model, OpenStudio.convert(20_000, 'ft^2', 'm^2').get) + + # For each group, infer the HVAC system type. + sys_groups.each do |sys_group| + # Infer the primary system type + # OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "template = #{args['template']}, climate_zone = #{climate_zone}, occ_type = #{sys_group['type']}, hvac_delivery = #{hvac_delivery}, htg_src = #{args['htg_src']}, clg_src = #{args['clg_src']}, area_ft2 = #{sys_group['area_ft2']}, num_stories = #{sys_group['stories']}") + sys_type, central_htg_fuel, zone_htg_fuel, clg_fuel = standard.model_typical_hvac_system_type(model, + climate_zone, + sys_group['type'], + hvac_delivery, + args['htg_src'], + args['clg_src'], + OpenStudio.convert(sys_group['area_ft2'], 'ft^2', 'm^2').get, + sys_group['stories']) + + # Infer the secondary system type for multizone systems + sec_sys_type = case sys_type + when 'PVAV Reheat', 'VAV Reheat' + 'PSZ-AC' + when 'PVAV PFP Boxes', 'VAV PFP Boxes' + 'PSZ-HP' + else + sys_type # same as primary system type + end + + # group zones + if haystack_file.nil? + # Group zones by story + bldg_zone_lists = standard.model_group_zones_by_story(model, sys_group['zones']) + else + # todo - group zones using haystack file instead of building stories + # todo - need to do something similar to use haystack to indentify secondary zones + bldg_zone_lists = standard.model_group_zones_by_story(model, sys_group['zones']) + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "***This code will define which zones are on air loops for inferred system***") + end + + # On each story, add the primary system to the primary zones + # and add the secondary system to any zones that are different. + bldg_zone_lists.each do |story_group| + # Differentiate primary and secondary zones, based on + # operating hours and internal loads (same as 90.1 PRM) + pri_sec_zone_lists = standard.model_differentiate_primary_secondary_thermal_zones(model, story_group) + system_zones = pri_sec_zone_lists['primary'] + + # if the primary system type is PTAC, filter to cooled zones to prevent sizing error if no cooling + if sys_type == 'PTAC' + heated_and_cooled_zones = system_zones.select { |zone| standard.thermal_zone_heated?(zone) && standard.thermal_zone_cooled?(zone) } + cooled_only_zones = system_zones.select { |zone| !standard.thermal_zone_heated?(zone) && standard.thermal_zone_cooled?(zone) } + system_zones = heated_and_cooled_zones + cooled_only_zones + end + + # Add the primary system to the primary zones + unless standard.model_add_hvac_system(model, sys_type, central_htg_fuel, zone_htg_fuel, clg_fuel, system_zones) + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "HVAC system type '#{sys_type}' not recognized. Check input system type argument against Model.hvac.rb for valid hvac system type names.") + return false + end + + # Add the secondary system to the secondary zones (if any) + if !pri_sec_zone_lists['secondary'].empty? + system_zones = pri_sec_zone_lists['secondary'] + if (sec_sys_type == 'PTAC') || (sec_sys_type == 'PSZ-AC') + heated_and_cooled_zones = system_zones.select { |zone| standard.thermal_zone_heated?(zone) && standard.thermal_zone_cooled?(zone) } + cooled_only_zones = system_zones.select { |zone| !standard.thermal_zone_heated?(zone) && standard.thermal_zone_cooled?(zone) } + system_zones = heated_and_cooled_zones + cooled_only_zones + end + unless standard.model_add_hvac_system(model, sec_sys_type, central_htg_fuel, zone_htg_fuel, clg_fuel, system_zones) + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "HVAC system type '#{sys_type}' not recognized. Check input system type argument against Model.hvac.rb for valid hvac system type names.") + return false + end + end + end + end + + else # HVAC system_type specified + + # Group the zones by occupancy type. Only split out non-dominant groups if their total area exceeds the limit. + sys_groups = standard.model_group_zones_by_type(model, OpenStudio.convert(20_000, 'ft^2', 'm^2').get) + sys_groups.each do |sys_group| + + # group zones + if haystack_file.nil? + # Group zones by story + bldg_zone_groups = standard.model_group_zones_by_story(model, sys_group['zones']) + else + # todo - group zones using haystack file instead of building stories + # todo - need to do something similar to use haystack to indentify secondary zones + bldg_zone_groups = standard.model_group_zones_by_story(model, sys_group['zones']) + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "***This code will define which zones are on air loops for user specified system***") + end + + # Add the user specified HVAC system for each story. + # Single-zone systems will get one per zone. + bldg_zone_groups.each do |zones| + unless model.add_cbecs_hvac_system(standard, args['system_type'], zones) + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "HVAC system type '#{args['system_type']}' not recognized. Check input system type argument against Model.hvac.rb for valid hvac system type names.") + return false + end + end + end + end + end + + # hours of operation + if args['modify_wkdy_op_hrs'] || args['modify_wknd_op_hrs'] + # Infer the current hours of operation schedule for the building + op_sch = standard.model_infer_hours_of_operation_building(model) + + # setup hoo_var_method (should be hours or fractional) + if args.has_key?('hoo_var_method') + hoo_var_method = args['hoo_var_method'] + else + # support measures that don't supply this argument + hoo_var_method = 'hours' + end + + # Convert existing schedules in the model to parametric schedules based on current hours of operation + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Generating parametric schedules from ruleset schedules using #{hoo_var_method} variable method for hours of operation fromula.") + standard.model_setup_parametric_schedules(model, hoo_var_method: hoo_var_method) + + # Create start and end times from start time and duration supplied + wkdy_start_time = nil + wkdy_end_time = nil + wknd_start_time = nil + wknd_end_time = nil + # weekdays + if args['modify_wkdy_op_hrs'] + wkdy_start_time = OpenStudio::Time.new(0, wkdy_op_hrs_start_time_hr, wkdy_op_hrs_start_time_min, 0) + wkdy_end_time = wkdy_start_time + OpenStudio::Time.new(0, wkdy_op_hrs_duration_hr, wkdy_op_hrs_duration_min, 0) + end + # weekends + if args['modify_wknd_op_hrs'] + wknd_start_time = OpenStudio::Time.new(0, wknd_op_hrs_start_time_hr, wknd_op_hrs_start_time_min, 0) + wknd_end_time = wknd_start_time + OpenStudio::Time.new(0, wknd_op_hrs_duration_hr, wknd_op_hrs_duration_min, 0) + end + + # Modify hours of operation, using weekdays values for all weekdays and weekend values for Saturday and Sunday + standard.schedule_ruleset_set_hours_of_operation(op_sch, + wkdy_start_time: wkdy_start_time, + wkdy_end_time: wkdy_end_time, + sat_start_time: wknd_start_time, + sat_end_time: wknd_end_time, + sun_start_time: wknd_start_time, + sun_end_time: wknd_end_time) + + # Apply new operating hours to parametric schedules to make schedules in model reflect modified hours of operation + parametric_schedules = standard.model_apply_parametric_schedules(model, error_on_out_of_order: false) + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Updated #{parametric_schedules.size} schedules with new hours of operation.") + end + + # set hvac controls and efficiencies (this should be last model articulation element) + if args['add_hvac'] + # set additional properties for building + props = model.getBuilding.additionalProperties + props.setFeature('hvac_system_type', (args['system_type']).to_s) + + case args['system_type'] + when 'Ideal Air Loads' + + else + # Set the heating and cooling sizing parameters + standard.model_apply_prm_sizing_parameters(model) + + # Perform a sizing run + if standard.model_run_sizing_run(model, "#{Dir.pwd}/SR1") == false + log_messages_to_runner(runner, debug = true) + return false + end + + # If there are any multizone systems, reset damper positions + # to achieve a 60% ventilation effectiveness minimum for the system + # following the ventilation rate procedure from 62.1 + standard.model_apply_multizone_vav_outdoor_air_sizing(model) + + # Apply the prototype HVAC assumptions + standard.model_apply_prototype_hvac_assumptions(model, primary_bldg_type, climate_zone) + + # Apply the HVAC efficiency standard + standard.model_apply_hvac_efficiency_standard(model, climate_zone) + end + end + + # add internal mass + if args['add_internal_mass'] + + if args['remove_objects'] + model.getSpaceLoads.sort.each do |instance| + next unless instance.to_InternalMass.is_initialized + instance.remove + end + end + + # add internal mass to conditioned spaces; needs to happen after thermostats are applied + standard.model_add_internal_mass(model, primary_bldg_type) + end + + # set unmet hours tolerance + unmet_hrs_tol_r = args['unmet_hours_tolerance'] + unmet_hrs_tol_k = OpenStudio.convert(unmet_hrs_tol_r, 'R', 'K').get + tolerances = model.getOutputControlReportingTolerances + tolerances.setToleranceforTimeHeatingSetpointNotMet(unmet_hrs_tol_k) + tolerances.setToleranceforTimeCoolingSetpointNotMet(unmet_hrs_tol_k) + + # remove everything but spaces, zones, and stub space types (extend as needed for additional objects, may make bool arg for this) + if args['remove_objects'] + model.purgeUnusedResourceObjects + objects_after_cleanup = initial_objects - model.getModelObjects.size + if objects_after_cleanup > 0 + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Removing #{objects_after_cleanup} objects from model") + end + end + + # change night cycling control to "Thermostat" cycling and increase thermostat tolerance to 1.99999 + manager_night_cycles = model.getAvailabilityManagerNightCycles + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Changing thermostat tollerance to 1.99999 for #{manager_night_cycles.size} night cycle manager objects.") + + manager_night_cycles.each do |night_cycle| + night_cycle.setThermostatTolerance(1.9999) + night_cycle.setCyclingRunTimeControlType("Thermostat") + end + + # report final condition of model + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "The building finished with #{model.getModelObjects.size} objects.") + + # log messages to info messages + log_messages_to_runner(runner, debug = false) + + return true + end + + # creates spaces types and construction objects in the model for the given + # building type, template, and climate zone + # + # @param building_type [String] standard building type + # @param template [String] standard template + # @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A' + # @param create_space_types [Boolean] Create space types + # @param create_construction_set [Boolean] Create the construction set + # @param set_building_defaults [Boolean] Set the climate zone, newly generated construction set, + # and first newly generated space type as the building default + # @return [Boolean] returns true if successful, false if not + def self.create_space_types_and_constructions(model, + building_type, + template, + climate_zone, + create_space_types: true, + create_construction_set: true, + set_building_defaults: true) + # reporting initial condition of model + starting_spaceTypes = model.getSpaceTypes.sort + starting_constructionSets = model.getDefaultConstructionSets.sort + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "The building started with #{starting_spaceTypes.size} space types and #{starting_constructionSets.size} construction sets.") + + # lookup space types for specified building type (false indicates not to use whole building type only) + space_type_hash = get_space_types_from_building_type(building_type, template, false) + if space_type_hash == false + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "#{building_type} is an unexpected building type.") + return false + end + + # create space_type_map from array + space_type_map = {} + default_space_type_name = nil + space_type_hash.each do |space_type_name, hash| + next if hash[:space_type_gen] == false # space types like undeveloped and basement are skipped. + space_type_map[space_type_name] = [] # no spaces to pass in + if hash[:default] + default_space_type_name = space_type_name + end + end + + # Make the standard applier + standard = Standard.build(template) + + # mapping building_type name is needed for a few methods + lookup_building_type = standard.model_get_lookup_name(building_type) + + # get array of new space types + space_types_new = [] + + # create_space_types + if create_space_types + + # array of starting space types + space_types_starting = model.getSpaceTypes.sort + + # create stub space types + space_type_hash.each do |space_type_name, hash| + next if hash[:space_type_gen] == false # space types like undeveloped and basement are skipped. + + # create space type + space_type = OpenStudio::Model::SpaceType.new(model) + space_type.setStandardsBuildingType(lookup_building_type) + space_type.setStandardsSpaceType(space_type_name) + space_type.setName("#{lookup_building_type} #{space_type_name}") + + # add to array of new space types + space_types_new << space_type + + # add internal loads (the nil check isn't necessary, but I will keep it in as a warning instad of an error) + test = standard.space_type_apply_internal_loads(space_type, true, true, true, true, true, true) + if test.nil? + OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.CreateTypical', "Could not add loads for #{space_type.name}. Not expected for #{template} #{lookup_building_type}") + end + + # the last bool test it to make thermostat schedules. They are added to the model but not assigned + standard.space_type_apply_internal_load_schedules(space_type, true, true, true, true, true, true, true) + + # assign colors + standard.space_type_apply_rendering_color(space_type) + + # exend space type name to include the template. Consider this as well for load defs + space_type.setName("#{space_type.name} - #{template}") + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Added space type named #{space_type.name}") + end + + end + + # add construction sets + bldg_def_const_set = nil + if create_construction_set + + # Make the default construction set for the building + is_residential = 'No' # default is nonresidential for building level + bldg_def_const_set = standard.model_add_construction_set(model, climate_zone, lookup_building_type, nil, is_residential) + if bldg_def_const_set.is_initialized + bldg_def_const_set = bldg_def_const_set.get + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Added default construction set named #{bldg_def_const_set.name}") + else + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', 'Could not create default construction set for the building.') + return false + end + + # make residential construction set as unused resource + if ['SmallHotel', 'LargeHotel', 'MidriseApartment', 'HighriseApartment'].include?(building_type) + res_const_set = standard.model_add_construction_set(model, climate_zone, lookup_building_type, nil, 'Yes') + if res_const_set.is_initialized + res_const_set = res_const_set.get + res_const_set.setName("#{bldg_def_const_set.name} - Residential ") + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Added residential construction set named #{res_const_set.name}") + else + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', 'Could not create residential construction set for the building.') + return false + end + end + + end + + # set_building_defaults + if set_building_defaults + + # identify default space type + space_type_standards_info_hash = OsLib_HelperMethods.getSpaceTypeStandardsInformation(space_types_new) + default_space_type = nil + space_type_standards_info_hash.each do |space_type, standards_array| + standards_space_type = standards_array[1] + if default_space_type_name == standards_space_type + default_space_type = space_type + end + end + + # set default space type + building = model.getBuilding + if !default_space_type.nil? + building.setSpaceType(default_space_type) + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Setting default Space Type for building to #{building.spaceType.get.name}") + end + + # default construction + if !bldg_def_const_set.nil? + building.setDefaultConstructionSet(bldg_def_const_set) + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Setting default Construction Set for building to #{building.defaultConstructionSet.get.name}") + end + + # set climate zone + os_climate_zone = climate_zone.gsub('ASHRAE 169-2013-', '') + # trim off letter from climate zone 7 or 8 + if (os_climate_zone[0] == '7') || (os_climate_zone[0] == '8') + os_climate_zone = os_climate_zone[0] + end + climate_zone = model.getClimateZones.setClimateZone('ASHRAE', os_climate_zone) + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Setting #{climate_zone.institution} Climate Zone to #{climate_zone.value}") + + # set building type + # use lookup_building_type so spaces like MediumOffice will map to Office (Supports baseline automation) + building.setStandardsBuildingType(lookup_building_type) + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Setting Standards Building Type to #{building.standardsBuildingType}") + + # rename building if it is named "Building 1" + if model.getBuilding.name.to_s == 'Building 1' + model.getBuilding.setName("#{building_type} #{template} #{os_climate_zone}") + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Renaming building to #{model.getBuilding.name}") + end + + end + + # reporting final condition of model + finishing_spaceTypes = model.getSpaceTypes.sort + finishing_constructionSets = model.getDefaultConstructionSets.sort + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "The building finished with #{finishing_spaceTypes.size} space types and #{finishing_constructionSets.size} construction sets.") + + return true + end + end +end \ No newline at end of file diff --git a/lib/openstudio-standards/create_typical/enumerations.rb b/lib/openstudio-standards/create_typical/enumerations.rb new file mode 100644 index 0000000000..c99af4750d --- /dev/null +++ b/lib/openstudio-standards/create_typical/enumerations.rb @@ -0,0 +1,289 @@ +# Methods to create available inputs for typical models +module OpenstudioStandards + module CreateTypical + # @!group CreateTypicalEnumerations + + # Get DOE building types + # + # @param extended [Boolean] set to true to return additional building types + # @return [OpenStudio::StringVector] array of building type strings + def self.get_doe_building_types(extended = false) + # DOE Prototypes + array = OpenStudio::StringVector.new + array << 'SecondarySchool' + array << 'PrimarySchool' + array << 'SmallOffice' + array << 'MediumOffice' + array << 'LargeOffice' + array << 'SmallHotel' + array << 'LargeHotel' + array << 'Warehouse' + array << 'RetailStandalone' + array << 'RetailStripmall' + array << 'QuickServiceRestaurant' + array << 'FullServiceRestaurant' + array << 'MidriseApartment' + array << 'HighriseApartment' + array << 'Hospital' + array << 'Outpatient' + array << 'SuperMarket' + array << 'Laboratory' + array << 'LargeDataCenterLowITE' + array << 'LargeDataCenterHighITE' + array << 'SmallDataCenterLowITE' + array << 'SmallDataCenterHighITE' + array << 'Courthouse' + array << 'College' + + return array + end + + # Get DEER building types + # + # @param extended [Boolean] set to true to return additional building types + # @return [OpenStudio::StringVector] array of building type strings + def self.get_deer_building_types(extended = false) + # DOE Prototypes + array = OpenStudio::StringVector.new + array << 'Asm' + array << 'DMo' + array << 'ECC' + array << 'EPr' + array << 'ERC' + array << 'ESe' + array << 'EUn' + array << 'GHs' + array << 'Gro' + array << 'Hsp' + array << 'Htl' + array << 'MBT' + array << 'MFm' + array << 'MLI' + array << 'Mtl' + array << 'Nrs' + array << 'OfL' + array << 'OfS' + array << 'RFF' + array << 'RSD' + array << 'Rt3' + array << 'RtL' + array << 'RtS' + array << 'SCn' + array << 'SFm' + array << 'SUn' + array << 'WRf' + + return array + end + + # list of building types that are valid for get_space_types_from_building_type + # + # @param extended [Boolean] set to true to return additional building types + # @return [OpenStudio::StringVector] array of building type strings + def self.get_building_types(extended = false) + # get building_types + if extended + doe = get_doe_building_types(true) + deer = get_deer_building_types(true) + else + doe = get_doe_building_types + deer = get_deer_building_types + end + + # combine building_types + array = OpenStudio::StringVector.new + temp_array = doe.to_a + deer.to_a + temp_array.each do |i| + array << i + end + + return array + end + + # Get DOE templates + # + # @param extended [Boolean] set to true to return additional templates + # @return [OpenStudio::StringVector] array of available standard templates as strings + def self.get_doe_templates(extended = false) + array = OpenStudio::StringVector.new + array << 'DOE Ref Pre-1980' + array << 'DOE Ref 1980-2004' + array << '90.1-2004' + array << '90.1-2007' + array << '90.1-2010' + array << '90.1-2013' + array << '90.1-2016' + array << '90.1-2019' + array << 'ComStock DOE Ref Pre-1980' + array << 'ComStock DOE Ref 1980-2004' + array << 'ComStock 90.1-2004' + array << 'ComStock 90.1-2007' + array << 'ComStock 90.1-2010' + array << 'ComStock 90.1-2013' + array << 'ComStock 90.1-2016' + array << 'ComStock 90.1-2019' + if extended + # array << '189.1-2009' # if turn this on need to update space_type_array for RetailStripmall + array << 'NREL ZNE Ready 2017' + end + + return array + end + + # Get DEER templates + # + # @param extended [Boolean] set to true to return additional templates + # @return [OpenStudio::StringVector] array of available standard templates as strings + def self.get_deer_templates(extended = false) + array = OpenStudio::StringVector.new + array << 'DEER Pre-1975' + array << 'DEER 1985' + array << 'DEER 1996' + array << 'DEER 2003' + array << 'DEER 2007' + array << 'DEER 2011' + array << 'DEER 2014' + array << 'DEER 2015' + array << 'DEER 2017' + array << 'DEER 2020' + if extended + array << 'DEER 2025' + array << 'DEER 2030' + array << 'DEER 2035' + array << 'DEER 2040' + array << 'DEER 2045' + array << 'DEER 2050' + array << 'DEER 2055' + array << 'DEER 2060' + array << 'DEER 2065' + array << 'DEER 2070' + array << 'DEER 2075' + end + + return array + end + + # list of templates that are valid for get_space_types_from_building_type + # + # @param extended [Boolean] set to true to return additional templates + # @return [OpenStudio::StringVector] array of available standard templates as strings + def self.get_templates(extended = false) + # get templates + if extended + doe = get_doe_templates(true) + deer = get_deer_templates(true) + else + doe = get_doe_templates + deer = get_deer_templates + end + + # combine templates + array = OpenStudio::StringVector.new + temp_array = doe.to_a + deer.to_a + temp_array.each do |i| + array << i + end + + return array + end + + # Get DOE climate zones + # + # @param extended [Boolean] set to true to return additional climate zones + # @param extra [String] extra climate zone to append to list + # @return [OpenStudio::StringVector] array of available climate zones as strings + def self.get_doe_climate_zones(extended = false, extra = nil) + # Lookup From Model should be added as an option where appropriate in the measure + cz_choices = OpenStudio::StringVector.new + if !extra.nil? + cz_choices << extra + end + cz_choices << 'ASHRAE 169-2013-1A' + cz_choices << 'ASHRAE 169-2013-1B' + cz_choices << 'ASHRAE 169-2013-2A' + cz_choices << 'ASHRAE 169-2013-2B' + cz_choices << 'ASHRAE 169-2013-3A' + cz_choices << 'ASHRAE 169-2013-3B' + cz_choices << 'ASHRAE 169-2013-3C' + cz_choices << 'ASHRAE 169-2013-4A' + cz_choices << 'ASHRAE 169-2013-4B' + cz_choices << 'ASHRAE 169-2013-4C' + cz_choices << 'ASHRAE 169-2013-5A' + cz_choices << 'ASHRAE 169-2013-5B' + cz_choices << 'ASHRAE 169-2013-5C' + cz_choices << 'ASHRAE 169-2013-6A' + cz_choices << 'ASHRAE 169-2013-6B' + cz_choices << 'ASHRAE 169-2013-7A' + cz_choices << 'ASHRAE 169-2013-8A' + if extended + cz_choices << 'ASHRAE 169-2013-0A' + cz_choices << 'ASHRAE 169-2013-0B' + end + + return cz_choices + end + + # Get DEER climate zones + # + # @param extended [Boolean] set to true to return additional climate zones + # @param extra [String] extra climate zone to append to list + # @return [OpenStudio::StringVector] array of available climate zones as strings + def self.get_deer_climate_zones(extended = false, extra = nil) + # Lookup From Model should be added as an option where appropriate in the measure + cz_choices = OpenStudio::StringVector.new + if !extra.nil? + cz_choices << extra + end + cz_choices << 'CEC T24-CEC1' + cz_choices << 'CEC T24-CEC2' + cz_choices << 'CEC T24-CEC3' + cz_choices << 'CEC T24-CEC4' + cz_choices << 'CEC T24-CEC5' + cz_choices << 'CEC T24-CEC6' + cz_choices << 'CEC T24-CEC7' + cz_choices << 'CEC T24-CEC8' + cz_choices << 'CEC T24-CEC9' + cz_choices << 'CEC T24-CEC10' + cz_choices << 'CEC T24-CEC11' + cz_choices << 'CEC T24-CEC12' + cz_choices << 'CEC T24-CEC13' + cz_choices << 'CEC T24-CEC14' + cz_choices << 'CEC T24-CEC15' + cz_choices << 'CEC T24-CEC16' + + return cz_choices + end + + # Get climate zones + # + # @param extended [Boolean] set to true to return additional climate zones + # @param extra [String] extra climate zone to append to list + # @return [OpenStudio::StringVector] array of available climate zones as strings + def self.get_climate_zones(extended = false, extra = nil) + + # get climate_zones + if extended && extra != nil + doe = get_doe_climate_zones(true, extra) + deer = get_deer_climate_zones(true, nil) + elsif extended + doe = get_doe_climate_zones(true, nil) + deer = get_deer_climate_zones(true, nil) + elsif extra != nil + doe = get_doe_climate_zones(false, extra) + deer = get_deer_climate_zones(false, nil) + else + doe = get_doe_climate_zones + deer = get_deer_climate_zones + end + + # combine climate zones + array = OpenStudio::StringVector.new + temp_array = doe.to_a + deer.to_a + temp_array.each do |i| + array << i + end + + return array + end + end +end \ No newline at end of file diff --git a/lib/openstudio-standards/create_typical/space_type_ratios.rb b/lib/openstudio-standards/create_typical/space_type_ratios.rb new file mode 100644 index 0000000000..c539150aa9 --- /dev/null +++ b/lib/openstudio-standards/create_typical/space_type_ratios.rb @@ -0,0 +1,474 @@ +# Methods to create available inputs for typical models +module OpenstudioStandards + module CreateTypical + + # create hash of space types and generic ratios of building floor area. + # some building type and template combination are incompatible + # + # @param building_type [String] standard building type + # @param template [String] standard template + # @param whole_building [Boolean] use a whole building space type for Office types + # @return [Hash] hash of space types + # @todo this method will be replaced with space type specific edits + # @todo enable each building type and template combination + def self.get_space_types_from_building_type(building_type, template, whole_building = true) + hash = {} + + # DOE Prototypes + if building_type == 'SecondarySchool' + if ['DOE Ref Pre-1980', 'DOE Ref 1980-2004', 'ComStock DOE Ref Pre-1980', 'ComStock DOE Ref 1980-2004'].include?(template) + hash['Auditorium'] = { ratio: 0.0504, space_type_gen: true, default: false, story_height: 26.0 } + hash['Cafeteria'] = { ratio: 0.0319, space_type_gen: true, default: false } + hash['Classroom'] = { ratio: 0.3528, space_type_gen: true, default: true } + hash['Corridor'] = { ratio: 0.2144, space_type_gen: true, default: false, circ: true } + hash['Gym'] = { ratio: 0.1009, space_type_gen: true, default: false, story_height: 26.0 } + hash['Gym - audience'] = { ratio: 0.0637, space_type_gen: true, default: false, story_height: 26.0 } + hash['Kitchen'] = { ratio: 0.0110, space_type_gen: true, default: false } + hash['Library'] = { ratio: 0.0429, space_type_gen: true, default: false } + hash['Lobby'] = { ratio: 0.0214, space_type_gen: true, default: false } + hash['Mechanical'] = { ratio: 0.0349, space_type_gen: true, default: false } + hash['Office'] = { ratio: 0.0543, space_type_gen: true, default: false } + hash['Restroom'] = { ratio: 0.0214, space_type_gen: true, default: false } + else + hash['Auditorium'] = { ratio: 0.0504, space_type_gen: true, default: false, story_height: 26.0 } + hash['Cafeteria'] = { ratio: 0.0319, space_type_gen: true, default: false } + hash['Classroom'] = { ratio: 0.3041, space_type_gen: true, default: true } + hash['ComputerRoom'] = { ratio: 0.0487, space_type_gen: true, default: true } + hash['Corridor'] = { ratio: 0.2144, space_type_gen: true, default: false, circ: true } + hash['Gym'] = { ratio: 0.1646, space_type_gen: true, default: false, story_height: 26.0 } + hash['Kitchen'] = { ratio: 0.0110, space_type_gen: true, default: false } + hash['Library'] = { ratio: 0.0429, space_type_gen: true, default: false } + hash['Lobby'] = { ratio: 0.0214, space_type_gen: true, default: false } + hash['Mechanical'] = { ratio: 0.0349, space_type_gen: true, default: false } + hash['Office'] = { ratio: 0.0543, space_type_gen: true, default: false } + hash['Restroom'] = { ratio: 0.0214, space_type_gen: true, default: false } + end + elsif building_type == 'PrimarySchool' + if ['DOE Ref Pre-1980', 'DOE Ref 1980-2004', 'ComStock DOE Ref Pre-1980', 'ComStock DOE Ref 1980-2004'].include?(template) + # updated to 2004 which includes library vs. pre-1980 + hash['Cafeteria'] = { ratio: 0.0458, space_type_gen: true, default: false } + hash['Classroom'] = { ratio: 0.5610, space_type_gen: true, default: true } + hash['Corridor'] = { ratio: 0.1633, space_type_gen: true, default: false, circ: true } + hash['Gym'] = { ratio: 0.0520, space_type_gen: true, default: false } + hash['Kitchen'] = { ratio: 0.0244, space_type_gen: true, default: false } + hash['Library'] = { ratio: 0.0, space_type_gen: true, default: false } # no library in model + hash['Lobby'] = { ratio: 0.0249, space_type_gen: true, default: false } + hash['Mechanical'] = { ratio: 0.0367, space_type_gen: true, default: false } + hash['Office'] = { ratio: 0.0642, space_type_gen: true, default: false } + hash['Restroom'] = { ratio: 0.0277, space_type_gen: true, default: false } + else + # updated to 2004 which includes library vs. pre-1980 + hash['Cafeteria'] = { ratio: 0.0458, space_type_gen: true, default: false } + hash['Classroom'] = { ratio: 0.4793, space_type_gen: true, default: true } + hash['ComputerRoom'] = { ratio: 0.0236, space_type_gen: true, default: true } + hash['Corridor'] = { ratio: 0.1633, space_type_gen: true, default: false, circ: true } + hash['Gym'] = { ratio: 0.0520, space_type_gen: true, default: false } + hash['Kitchen'] = { ratio: 0.0244, space_type_gen: true, default: false } + hash['Library'] = { ratio: 0.0581, space_type_gen: true, default: false } + hash['Lobby'] = { ratio: 0.0249, space_type_gen: true, default: false } + hash['Mechanical'] = { ratio: 0.0367, space_type_gen: true, default: false } + hash['Office'] = { ratio: 0.0642, space_type_gen: true, default: false } + hash['Restroom'] = { ratio: 0.0277, space_type_gen: true, default: false } + end + elsif building_type == 'SmallOffice' + # @todo populate Small, Medium, and Large office for whole_building false + if whole_building + hash['WholeBuilding - Sm Office'] = { ratio: 1.0, space_type_gen: true, default: true } + else + hash['SmallOffice - Breakroom'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['SmallOffice - ClosedOffice'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['SmallOffice - Conference'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['SmallOffice - Corridor'] = { ratio: 0.99, space_type_gen: true, default: false, circ: true } + hash['SmallOffice - Elec/MechRoom'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['SmallOffice - Lobby'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['SmallOffice - OpenOffice'] = { ratio: 0.99, space_type_gen: true, default: true } + hash['SmallOffice - Restroom'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['SmallOffice - Stair'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['SmallOffice - Storage'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['SmallOffice - Classroom'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['SmallOffice - Dining'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['WholeBuilding - Sm Office'] = { ratio: 0.0, space_type_gen: true, default: false } + end + elsif building_type == 'MediumOffice' + if whole_building + hash['WholeBuilding - Md Office'] = { ratio: 1.0, space_type_gen: true, default: true } + else + hash['MediumOffice - Breakroom'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['MediumOffice - ClosedOffice'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['MediumOffice - Conference'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['MediumOffice - Corridor'] = { ratio: 0.99, space_type_gen: true, default: false, circ: true } + hash['MediumOffice - Elec/MechRoom'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['MediumOffice - Lobby'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['MediumOffice - OpenOffice'] = { ratio: 0.99, space_type_gen: true, default: true } + hash['MediumOffice - Restroom'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['MediumOffice - Stair'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['MediumOffice - Storage'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['MediumOffice - Classroom'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['MediumOffice - Dining'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['WholeBuilding - Md Office'] = { ratio: 0.0, space_type_gen: true, default: false } + end + elsif building_type == 'LargeOffice' + if ['DOE Ref Pre-1980', 'DOE Ref 1980-2004', 'ComStock DOE Ref Pre-1980', 'ComStock DOE Ref 1980-2004'].include?(template) + if whole_building + hash['WholeBuilding - Lg Office'] = { ratio: 1.0, space_type_gen: true, default: true } + else + hash['BreakRoom'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['ClosedOffice'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['Conference'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['Corridor'] = { ratio: 0.99, space_type_gen: true, default: false, circ: true } + hash['Elec/MechRoom'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['IT_Room'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['Lobby'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['OpenOffice'] = { ratio: 0.99, space_type_gen: true, default: true } + hash['PrintRoom'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['Restroom'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['Stair'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['Storage'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['Vending'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['WholeBuilding - Lg Office'] = { ratio: 0.0, space_type_gen: true, default: false } + end + else + if whole_building + hash['WholeBuilding - Lg Office'] = { ratio: 0.9737, space_type_gen: true, default: true } + hash['OfficeLarge Data Center'] = { ratio: 0.0094, space_type_gen: true, default: false } + hash['OfficeLarge Main Data Center'] = { ratio: 0.0169, space_type_gen: true, default: false } + else + hash['BreakRoom'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['ClosedOffice'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['Conference'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['Corridor'] = { ratio: 0.99, space_type_gen: true, default: false, circ: true } + hash['Elec/MechRoom'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['IT_Room'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['Lobby'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['OpenOffice'] = { ratio: 0.99, space_type_gen: true, default: true } + hash['PrintRoom'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['Restroom'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['Stair'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['Storage'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['Vending'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['WholeBuilding - Lg Office'] = { ratio: 0.0, space_type_gen: true, default: false } + hash['OfficeLarge Data Center'] = { ratio: 0.0, space_type_gen: true, default: false } + hash['OfficeLarge Main Data Center'] = { ratio: 0.0, space_type_gen: true, default: false } + end + end + elsif building_type == 'SmallHotel' + if ['DOE Ref Pre-1980', 'DOE Ref 1980-2004', 'ComStock DOE Ref Pre-1980', 'ComStock DOE Ref 1980-2004'].include?(template) + hash['Corridor'] = { ratio: 0.1313, space_type_gen: true, default: false, circ: true } + hash['Elec/MechRoom'] = { ratio: 0.0038, space_type_gen: true, default: false } + hash['ElevatorCore'] = { ratio: 0.0113, space_type_gen: true, default: false } + hash['Exercise'] = { ratio: 0.0081, space_type_gen: true, default: false } + hash['GuestLounge'] = { ratio: 0.0406, space_type_gen: true, default: false } + hash['GuestRoom'] = { ratio: 0.6313, space_type_gen: true, default: true } + hash['Laundry'] = { ratio: 0.0244, space_type_gen: true, default: false } + hash['Mechanical'] = { ratio: 0.0081, space_type_gen: true, default: false } + hash['Meeting'] = { ratio: 0.0200, space_type_gen: true, default: false } + hash['Office'] = { ratio: 0.0325, space_type_gen: true, default: false } + hash['PublicRestroom'] = { ratio: 0.0081, space_type_gen: true, default: false } + hash['StaffLounge'] = { ratio: 0.0081, space_type_gen: true, default: false } + hash['Stair'] = { ratio: 0.0400, space_type_gen: true, default: false } + hash['Storage'] = { ratio: 0.0325, space_type_gen: true, default: false } + else + hash['Corridor'] = { ratio: 0.1313, space_type_gen: true, default: false, circ: true } + hash['Elec/MechRoom'] = { ratio: 0.0038, space_type_gen: true, default: false } + hash['ElevatorCore'] = { ratio: 0.0113, space_type_gen: true, default: false } + hash['Exercise'] = { ratio: 0.0081, space_type_gen: true, default: false } + hash['GuestLounge'] = { ratio: 0.0406, space_type_gen: true, default: false } + hash['GuestRoom123Occ'] = { ratio: 0.4081, space_type_gen: true, default: true } + hash['GuestRoom123Vac'] = { ratio: 0.2231, space_type_gen: true, default: false } + hash['Laundry'] = { ratio: 0.0244, space_type_gen: true, default: false } + hash['Mechanical'] = { ratio: 0.0081, space_type_gen: true, default: false } + hash['Meeting'] = { ratio: 0.0200, space_type_gen: true, default: false } + hash['Office'] = { ratio: 0.0325, space_type_gen: true, default: false } + hash['PublicRestroom'] = { ratio: 0.0081, space_type_gen: true, default: false } + hash['StaffLounge'] = { ratio: 0.0081, space_type_gen: true, default: false } + hash['Stair'] = { ratio: 0.0400, space_type_gen: true, default: false } + hash['Storage'] = { ratio: 0.0325, space_type_gen: true, default: false } + end + elsif building_type == 'LargeHotel' + hash['Banquet'] = { ratio: 0.0585, space_type_gen: true, default: false } + hash['Basement'] = { ratio: 0.1744, space_type_gen: false, default: false } + hash['Cafe'] = { ratio: 0.0166, space_type_gen: true, default: false } + hash['Corridor'] = { ratio: 0.1736, space_type_gen: true, default: false, circ: true } + hash['GuestRoom'] = { ratio: 0.4099, space_type_gen: true, default: true } + hash['Kitchen'] = { ratio: 0.0091, space_type_gen: true, default: false } + hash['Laundry'] = { ratio: 0.0069, space_type_gen: true, default: false } + hash['Lobby'] = { ratio: 0.1153, space_type_gen: true, default: false } + hash['Mechanical'] = { ratio: 0.0145, space_type_gen: true, default: false } + hash['Retail'] = { ratio: 0.0128, space_type_gen: true, default: false } + hash['Storage'] = { ratio: 0.0084, space_type_gen: true, default: false } + elsif building_type == 'Warehouse' + hash['Bulk'] = { ratio: 0.6628, space_type_gen: true, default: true } + hash['Fine'] = { ratio: 0.2882, space_type_gen: true, default: false } + hash['Office'] = { ratio: 0.0490, space_type_gen: true, default: false, wwr: 0.71, story_height: 14.0 } + elsif building_type == 'RetailStandalone' + hash['Back_Space'] = { ratio: 0.1656, space_type_gen: true, default: false } + hash['Entry'] = { ratio: 0.0052, space_type_gen: true, default: false } + hash['Point_of_Sale'] = { ratio: 0.0657, space_type_gen: true, default: false } + hash['Retail'] = { ratio: 0.7635, space_type_gen: true, default: true } + elsif building_type == 'RetailStripmall' + hash['Strip mall - type 1'] = { ratio: 0.25, space_type_gen: true, default: false } + hash['Strip mall - type 2'] = { ratio: 0.25, space_type_gen: true, default: false } + hash['Strip mall - type 3'] = { ratio: 0.50, space_type_gen: true, default: true } + elsif building_type == 'QuickServiceRestaurant' + hash['Dining'] = { ratio: 0.5, space_type_gen: true, default: true } + hash['Kitchen'] = { ratio: 0.5, space_type_gen: true, default: false } + elsif building_type == 'FullServiceRestaurant' + hash['Dining'] = { ratio: 0.7272, space_type_gen: true, default: true } + hash['Kitchen'] = { ratio: 0.2728, space_type_gen: true, default: false } + elsif building_type == 'MidriseApartment' + hash['Apartment'] = { ratio: 0.8727, space_type_gen: true, default: true } + hash['Corridor'] = { ratio: 0.0991, space_type_gen: true, default: false, circ: true } + hash['Office'] = { ratio: 0.0282, space_type_gen: true, default: false } + elsif building_type == 'HighriseApartment' + hash['Apartment'] = { ratio: 0.8896, space_type_gen: true, default: true } + hash['Corridor'] = { ratio: 0.0991, space_type_gen: true, default: false, circ: true } + hash['Office'] = { ratio: 0.0113, space_type_gen: true, default: false } + elsif building_type == 'Hospital' + hash['Basement'] = { ratio: 0.1667, space_type_gen: false, default: false } + hash['Corridor'] = { ratio: 0.1741, space_type_gen: true, default: false, circ: true } + hash['Dining'] = { ratio: 0.0311, space_type_gen: true, default: false } + hash['ER_Exam'] = { ratio: 0.0099, space_type_gen: true, default: false } + hash['ER_NurseStn'] = { ratio: 0.0551, space_type_gen: true, default: false } + hash['ER_Trauma'] = { ratio: 0.0025, space_type_gen: true, default: false } + hash['ER_Triage'] = { ratio: 0.0050, space_type_gen: true, default: false } + hash['ICU_NurseStn'] = { ratio: 0.0298, space_type_gen: true, default: false } + hash['ICU_Open'] = { ratio: 0.0275, space_type_gen: true, default: false } + hash['ICU_PatRm'] = { ratio: 0.0115, space_type_gen: true, default: false } + hash['Kitchen'] = { ratio: 0.0414, space_type_gen: true, default: false } + hash['Lab'] = { ratio: 0.0236, space_type_gen: true, default: false } + hash['Lobby'] = { ratio: 0.0657, space_type_gen: true, default: false } + hash['NurseStn'] = { ratio: 0.1723, space_type_gen: true, default: false } + hash['Office'] = { ratio: 0.0286, space_type_gen: true, default: false } + hash['OR'] = { ratio: 0.0273, space_type_gen: true, default: false } + hash['PatCorridor'] = { ratio: 0.0, space_type_gen: true, default: false } # not in prototype + hash['PatRoom'] = { ratio: 0.0845, space_type_gen: true, default: true } + hash['PhysTherapy'] = { ratio: 0.0217, space_type_gen: true, default: false } + hash['Radiology'] = { ratio: 0.0217, space_type_gen: true, default: false } + elsif building_type == 'Outpatient' + hash['Anesthesia'] = { ratio: 0.0026, space_type_gen: true, default: false } + hash['BioHazard'] = { ratio: 0.0014, space_type_gen: true, default: false } + hash['Cafe'] = { ratio: 0.0103, space_type_gen: true, default: false } + hash['CleanWork'] = { ratio: 0.0071, space_type_gen: true, default: false } + hash['Conference'] = { ratio: 0.0082, space_type_gen: true, default: false } + hash['DressingRoom'] = { ratio: 0.0021, space_type_gen: true, default: false } + hash['Elec/MechRoom'] = { ratio: 0.0109, space_type_gen: true, default: false } + hash['ElevatorPumpRoom'] = { ratio: 0.0022, space_type_gen: true, default: false } + hash['Exam'] = { ratio: 0.1029, space_type_gen: true, default: true } + hash['Hall'] = { ratio: 0.1924, space_type_gen: true, default: false, circ: true } + hash['IT_Room'] = { ratio: 0.0027, space_type_gen: true, default: false } + hash['Janitor'] = { ratio: 0.0672, space_type_gen: true, default: false } + hash['Lobby'] = { ratio: 0.0152, space_type_gen: true, default: false } + hash['LockerRoom'] = { ratio: 0.0190, space_type_gen: true, default: false } + hash['Lounge'] = { ratio: 0.0293, space_type_gen: true, default: false } + hash['MedGas'] = { ratio: 0.0014, space_type_gen: true, default: false } + hash['MRI'] = { ratio: 0.0107, space_type_gen: true, default: false } + hash['MRI_Control'] = { ratio: 0.0041, space_type_gen: true, default: false } + hash['NurseStation'] = { ratio: 0.0189, space_type_gen: true, default: false } + hash['Office'] = { ratio: 0.1828, space_type_gen: true, default: false } + hash['OR'] = { ratio: 0.0346, space_type_gen: true, default: false } + hash['PACU'] = { ratio: 0.0232, space_type_gen: true, default: false } + hash['PhysicalTherapy'] = { ratio: 0.0462, space_type_gen: true, default: false } + hash['PreOp'] = { ratio: 0.0129, space_type_gen: true, default: false } + hash['ProcedureRoom'] = { ratio: 0.0070, space_type_gen: true, default: false } + hash['Reception'] = { ratio: 0.0365, space_type_gen: true, default: false } + hash['Soil Work'] = { ratio: 0.0088, space_type_gen: true, default: false } + hash['Stair'] = { ratio: 0.0146, space_type_gen: true, default: false } + hash['Toilet'] = { ratio: 0.0193, space_type_gen: true, default: false } + hash['Undeveloped'] = { ratio: 0.0835, space_type_gen: false, default: false } + hash['Xray'] = { ratio: 0.0220, space_type_gen: true, default: false } + elsif building_type == 'SuperMarket' + # @todo populate ratios for SuperMarket + hash['Bakery'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['Deli'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['DryStorage'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['Office'] = { ratio: 0.99, space_type_gen: true, default: false } + hash['Produce'] = { ratio: 0.99, space_type_gen: true, default: true } + hash['Sales'] = { ratio: 0.99, space_type_gen: true, default: true } + hash['Corridor'] = { ratio: 0.99, space_type_gen: true, default: true } + hash['Dining'] = { ratio: 0.99, space_type_gen: true, default: true } + hash['Elec/MechRoom'] = { ratio: 0.99, space_type_gen: true, default: true } + hash['Meeting'] = { ratio: 0.99, space_type_gen: true, default: true } + hash['Restroom'] = { ratio: 0.99, space_type_gen: true, default: true } + hash['Vestibule'] = { ratio: 0.99, space_type_gen: true, default: true } + elsif building_type == 'Laboratory' + hash['Office'] = { ratio: 0.50, space_type_gen: true, default: true } + hash['Open lab'] = { ratio: 0.35, space_type_gen: true, default: true } + hash['Equipment corridor'] = { ratio: 0.05, space_type_gen: true, default: true } + hash['Lab with fume hood'] = { ratio: 0.10, space_type_gen: true, default: true } + elsif building_type == 'LargeDataCenterHighITE' + hash['StandaloneDataCenter'] = { ratio: 1.0, space_type_gen: true, default: true } + elsif building_type == 'LargeDataCenterLowITE' + hash['StandaloneDataCenter'] = { ratio: 1.0, space_type_gen: true, default: true } + elsif building_type == 'SmallDataCenterHighITE' + hash['ComputerRoom'] = { ratio: 1.0, space_type_gen: true, default: true } + elsif building_type == 'SmallDataCenterLowITE' + hash['ComputerRoom'] = { ratio: 1.0, space_type_gen: true, default: true } + elsif building_type == 'Courthouse' + hash['Courthouse - Break Room'] = { ratio: 0.0067, space_type_gen: true, default: false } + hash['Courthouse - Cell'] = { ratio: 0.0731, space_type_gen: true, default: false } + hash['Courthouse - Conference'] = { ratio: 0.0203, space_type_gen: true, default: false } + hash['Courthouse - Corridor'] = { ratio: 0.0829, space_type_gen: true, default: false } + hash['Courthouse - Courtroom'] = { ratio: 0.1137, space_type_gen: true, default: false } + hash['Courthouse - Courtroom Waiting'] = { ratio: 0.051, space_type_gen: true, default: false } + hash['Courthouse - Elevator Lobby'] = { ratio: 0.0085, space_type_gen: true, default: false } + hash['Courthouse - Elevator Shaft'] = { ratio: 0.0047, space_type_gen: true, default: false } + hash['Courthouse - Entrance Lobby'] = { ratio: 0.0299, space_type_gen: true, default: false } + hash['Courthouse - Judges Chamber'] = { ratio: 0.0261, space_type_gen: true, default: false } + hash['Courthouse - Jury Assembly'] = { ratio: 0.0355, space_type_gen: true, default: false } + hash['Courthouse - Jury Deliberation'] = { ratio: 0.0133, space_type_gen: true, default: false } + hash['Courthouse - Library'] = { ratio: 0.0302, space_type_gen: true, default: false } + hash['Courthouse - Office'] = { ratio: 0.1930, space_type_gen: true, default: true } + hash['Courthouse - Parking'] = { ratio: 0.1083, space_type_gen: true, default: false } + hash['Courthouse - Restrooms'] = { ratio: 0.04, space_type_gen: true, default: false } + hash['Courthouse - Security Screening'] = { ratio: 0.0132, space_type_gen: true, default: false } + hash['Courthouse - Service Shaft'] = { ratio: 0.0019, space_type_gen: true, default: false } + hash['Courthouse - Stairs'] = { ratio: 0.0111, space_type_gen: true, default: false } + hash['Courthouse - Storage'] = { ratio: 0.0882, space_type_gen: true, default: false } + hash['Courthouse - Utility'] = { ratio: 0.0484, space_type_gen: true, default: false } + elsif building_type == 'College' + hash['College - Art Classroom'] = { ratio: 0.1868, space_type_gen: true, default: false } + hash['College - Classroom'] = { ratio: 0.2348, space_type_gen: true, default: true } + hash['College - Conference'] = { ratio: 0.0215, space_type_gen: true, default: false } + hash['College - Corridor'] = { ratio: 0.0716, space_type_gen: true, default: false } + hash['College - Elevator Shaft'] = { ratio: 0.0074, space_type_gen: true, default: false } + hash['College - Entrance Lobby'] = { ratio: 0.0117, space_type_gen: true, default: false } + hash['College - Laboratory'] = { ratio: 0.0843, space_type_gen: true, default: false } + hash['College - Lecture Hall'] = { ratio: 0.0421, space_type_gen: true, default: false } + hash['College - Lounge'] = { ratio: 0.028, space_type_gen: true, default: false } + hash['College - Media Center'] = { ratio: 0.0421, space_type_gen: true, default: false } + hash['College - Office'] = { ratio: 0.1894, space_type_gen: true, default: false } + hash['College - Restroom'] = { ratio: 0.0363, space_type_gen: true, default: false } + hash['College - Stairs'] = { ratio: 0.0272, space_type_gen: true, default: false } + hash['College - Storage'] = { ratio: 0.0117, space_type_gen: true, default: false } + hash['College - Utility'] = { ratio: 0.0051, space_type_gen: true, default: false } + # DEER Prototypes + elsif building_type == 'Asm' + hash['Auditorium'] = { ratio: 0.7658, space_type_gen: true, default: true } + hash['OfficeGeneral'] = { ratio: 0.2342, space_type_gen: true, default: false } + elsif building_type == 'ECC' + hash['Classroom'] = { ratio: 0.5558, space_type_gen: true, default: true } + hash['CompRoomClassRm'] = { ratio: 0.0319, space_type_gen: true, default: false } + hash['Shop'] = { ratio: 0.1249, space_type_gen: true, default: false } + hash['Dining'] = { ratio: 0.0876, space_type_gen: true, default: false } + hash['Kitchen'] = { ratio: 0.0188, space_type_gen: true, default: false } + hash['OfficeGeneral'] = { ratio: 0.181, space_type_gen: true, default: false } + elsif building_type == 'EPr' + hash['Classroom'] = { ratio: 0.53, space_type_gen: true, default: true } + hash['CorridorStairway'] = { ratio: 0.1, space_type_gen: true, default: false } + hash['Dining'] = { ratio: 0.15, space_type_gen: true, default: false } + hash['Gymnasium'] = { ratio: 0.15, space_type_gen: true, default: false } + hash['Kitchen'] = { ratio: 0.07, space_type_gen: true, default: false } + elsif building_type == 'ERC' + hash['Classroom'] = { ratio: 0.5, space_type_gen: true, default: true } + elsif building_type == 'ESe' + hash['Classroom'] = { ratio: 0.488, space_type_gen: true, default: true } + hash['CompRoomClassRm'] = { ratio: 0.021, space_type_gen: true, default: false } + hash['CorridorStairway'] = { ratio: 0.1, space_type_gen: true, default: false } + hash['Dining'] = { ratio: 0.15, space_type_gen: true, default: false } + hash['Gymnasium'] = { ratio: 0.15, space_type_gen: true, default: false } + hash['Kitchen'] = { ratio: 0.07, space_type_gen: true, default: false } + hash['OfficeGeneral'] = { ratio: 0.021, space_type_gen: true, default: true } + elsif building_type == 'EUn' + hash['Dining'] = { ratio: 0.0238, space_type_gen: true, default: false } + hash['Classroom'] = { ratio: 0.3056, space_type_gen: true, default: false } + hash['OfficeGeneral'] = { ratio: 0.3422, space_type_gen: true, default: true } + hash['CompRoomClassRm'] = { ratio: 0.038, space_type_gen: true, default: false } + hash['Kitchen'] = { ratio: 0.0105, space_type_gen: true, default: false } + hash['CorridorStairway'] = { ratio: 0.03, space_type_gen: true, default: false } + hash['FacMaint'] = { ratio: 0.08, space_type_gen: true, default: false } + hash['DormitoryRoom'] = { ratio: 0.1699, space_type_gen: true, default: false } + elsif building_type == 'Gro' + hash['GrocSales'] = { ratio: 0.8002, space_type_gen: true, default: true } + hash['RefWalkInCool'] = { ratio: 0.0312, space_type_gen: true, default: false } + hash['OfficeGeneral'] = { ratio: 0.07, space_type_gen: true, default: false } + hash['RefFoodPrep'] = { ratio: 0.0253, space_type_gen: true, default: false } + hash['RefWalkInFreeze'] = { ratio: 0.0162, space_type_gen: true, default: false } + hash['IndLoadDock'] = { ratio: 0.057, space_type_gen: true, default: false } + elsif building_type == 'Hsp' + hash['HspSurgOutptLab'] = { ratio: 0.2317, space_type_gen: true, default: false } + hash['Dining'] = { ratio: 0.0172, space_type_gen: true, default: false } + hash['Kitchen'] = { ratio: 0.0075, space_type_gen: true, default: false } + hash['OfficeGeneral'] = { ratio: 0.3636, space_type_gen: true, default: false } + hash['PatientRoom'] = { ratio: 0.38, space_type_gen: true, default: true } + elsif building_type == 'Htl' + hash['Dining'] = { ratio: 0.004, space_type_gen: true, default: false } + hash['BarCasino'] = { ratio: 0.005, space_type_gen: true, default: false } + hash['HotelLobby'] = { ratio: 0.0411, space_type_gen: true, default: false } + hash['OfficeGeneral'] = { ratio: 0.0205, space_type_gen: true, default: false } + hash['GuestRmCorrid'] = { ratio: 0.1011, space_type_gen: true, default: false } + hash['Laundry'] = { ratio: 0.0205, space_type_gen: true, default: false } + hash['GuestRmOcc'] = { ratio: 0.64224, space_type_gen: true, default: true } + hash['GuestRmUnOcc'] = { ratio: 0.16056, space_type_gen: true, default: true } + hash['Kitchen'] = { ratio: 0.005, space_type_gen: true, default: false } + elsif building_type == 'MBT' + hash['CompRoomData'] = { ratio: 0.02, space_type_gen: true, default: false } + hash['Laboratory'] = { ratio: 0.4534, space_type_gen: true, default: true } + hash['CorridorStairway'] = { ratio: 0.2, space_type_gen: true, default: false } + hash['Conference'] = { ratio: 0.02, space_type_gen: true, default: false } + hash['Dining'] = { ratio: 0.03, space_type_gen: true, default: false } + hash['OfficeOpen'] = { ratio: 0.2666, space_type_gen: true, default: false } + hash['Kitchen'] = { ratio: 0.01, space_type_gen: true, default: false } + elsif building_type == 'MFm' + hash['ResLiving'] = { ratio: 0.9297, space_type_gen: true, default: true } + hash['ResPublicArea'] = { ratio: 0.0725, space_type_gen: true, default: false } + elsif building_type == 'MLI' + hash['StockRoom'] = { ratio: 0.2, space_type_gen: true, default: false } + hash['Work'] = { ratio: 0.8, space_type_gen: true, default: true } + elsif building_type == 'Mtl' + hash['OfficeGeneral'] = { ratio: 0.02, space_type_gen: true, default: false } + hash['GuestRmCorrid'] = { ratio: 0.649, space_type_gen: true, default: true } + hash['Laundry'] = { ratio: 0.016, space_type_gen: true, default: false } + hash['GuestRmOcc'] = { ratio: 0.25208, space_type_gen: true, default: false } + hash['GuestRmUnOcc'] = { ratio: 0.06302, space_type_gen: true, default: false } + elsif building_type == 'Nrs' + hash['CorridorStairway'] = { ratio: 0.0555, space_type_gen: true, default: false } + hash['Dining'] = { ratio: 0.105, space_type_gen: true, default: false } + hash['Kitchen'] = { ratio: 0.045, space_type_gen: true, default: false } + hash['OfficeGeneral'] = { ratio: 0.35, space_type_gen: true, default: false } + hash['PatientRoom'] = { ratio: 0.4445, space_type_gen: true, default: true } + elsif building_type == 'OfL' + hash['LobbyWaiting'] = { ratio: 0.0412, space_type_gen: true, default: false } + hash['OfficeSmall'] = { ratio: 0.3704, space_type_gen: true, default: false } + hash['OfficeOpen'] = { ratio: 0.5296, space_type_gen: true, default: true } + hash['MechElecRoom'] = { ratio: 0.0588, space_type_gen: true, default: false } + elsif building_type == 'OfS' + hash['Hall'] = { ratio: 0.3141, space_type_gen: true, default: false } + hash['OfficeSmall'] = { ratio: 0.6859, space_type_gen: true, default: true } + elsif building_type == 'RFF' + hash['Dining'] = { ratio: 0.3997, space_type_gen: true, default: false } + hash['Kitchen'] = { ratio: 0.4, space_type_gen: true, default: true } + hash['LobbyWaiting'] = { ratio: 0.1501, space_type_gen: true, default: false } + hash['Restroom'] = { ratio: 0.0501, space_type_gen: true, default: false } + elsif building_type == 'RSD' + hash['Restroom'] = { ratio: 0.0357, space_type_gen: true, default: false } + hash['Dining'] = { ratio: 0.5353, space_type_gen: true, default: true } + hash['LobbyWaiting'] = { ratio: 0.1429, space_type_gen: true, default: false } + hash['Kitchen'] = { ratio: 0.2861, space_type_gen: true, default: false } + elsif building_type == 'Rt3' + hash['RetailSales'] = { ratio: 1.0, space_type_gen: true, default: true } + elsif building_type == 'RtL' + hash['OfficeGeneral'] = { ratio: 0.0359, space_type_gen: true, default: false } + hash['Work'] = { ratio: 0.04, space_type_gen: true, default: false } + hash['StockRoom'] = { ratio: 0.091, space_type_gen: true, default: false } + hash['RetailSales'] = { ratio: 0.8219, space_type_gen: true, default: true } + hash['Kitchen'] = { ratio: 0.0113, space_type_gen: true, default: false } + elsif building_type == 'RtS' + hash['RetailSales'] = { ratio: 0.8, space_type_gen: true, default: true } + hash['StockRoom'] = { ratio: 0.2, space_type_gen: true, default: false } + elsif building_type == 'SCn' + hash['WarehouseCond'] = { ratio: 1.0, space_type_gen: true, default: true } + elsif building_type == 'SUn' + hash['WarehouseUnCond'] = { ratio: 1.0, space_type_gen: true, default: true } + elsif building_type == 'WRf' + hash['IndLoadDock'] = { ratio: 0.08, space_type_gen: true, default: false } + hash['OfficeGeneral'] = { ratio: 0.02, space_type_gen: true, default: false } + hash['RefStorFreezer'] = { ratio: 0.4005, space_type_gen: true, default: false } + hash['RefStorCooler'] = { ratio: 0.4995, space_type_gen: true, default: true } + else + return false + end + + return hash + end + end +end \ No newline at end of file diff --git a/lib/openstudio-standards/geometry/create.rb b/lib/openstudio-standards/geometry/create.rb new file mode 100644 index 0000000000..33dfb1987e --- /dev/null +++ b/lib/openstudio-standards/geometry/create.rb @@ -0,0 +1,1855 @@ +# Methods to create geometry +module OpenstudioStandards + module Geometry + # @!group Create + + # Building Form Defaults from Table 4.2 in Achieving the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010 + # aspect ratio for NA replaced with floor area to perimeter ratio from prototype model + # currently no reason to split apart doe and deer inputs here + # + # @param building_type [String] standard building type + # @return [Hash] Hash of aspect_ratio, wwr, typical_story, and perim_mult + def self.building_form_defaults(building_type) + hash = {} + + # DOE Prototypes + + # calculate aspect ratios not represented on Table 4.2 + primary_footprint = 73958.0 + primary_p = 619.0 # wrote measure using calculate_perimeter method in os_lib_geometry + primary_ns_ew_ratio = 2.829268293 # estimated from ratio of ns/ew total wall area + primary_width = Math.sqrt(primary_footprint / primary_ns_ew_ratio) + primary_p_min = 2 * (primary_width + primary_width / primary_footprint) + primary_p_mult = primary_p / primary_p_min + + secondary_footprint = 210887.0 / 2.0 # floor area divided by area instead of true footprint 128112.0) + secondary_p = 708.0 # wrote measure using calculate_perimeter method in os_lib_geometry + secondary_ns_ew_ratio = 2.069230769 # estimated from ratio of ns/ew total wall area + secondary_width = Math.sqrt(secondary_footprint / secondary_ns_ew_ratio) + secondary_p_min = 2 * (secondary_width + secondary_width / secondary_footprint) + secondary_p_mult = secondary_p / secondary_p_min + + outpatient_footprint = 40946.0 / 3.0 # floor area divided by area instead of true footprint 17872.0) + outpatient_p = 537.0 # wrote measure using calculate_perimeter method in os_lib_geometry + outpatient_ns_ew_ratio = 1.56448737 # estimated from ratio of ns/ew total wall area + outpatient_width = Math.sqrt(outpatient_footprint / outpatient_ns_ew_ratio) + outpatient_p_min = 2 * (outpatient_width + outpatient_footprint / outpatient_width) + outpatient_p_mult = outpatient_p / outpatient_p_min + + # primary_aspet_ratio = calc_aspect_ratio(73958.0, 2060.0) + # secondary_aspet_ratio = calc_aspect_ratio(128112.0, 2447.0) + # outpatient_aspet_ratio = calc_aspect_ratio(14782.0, 588.0) + supermarket_a = 45001.0 + supermarket_p = 866.0 + supermarket_wwr = 1880.0 / (supermarket_p * 20.0) + supermarket_aspect_ratio = calc_aspect_ratio(supermarket_a, supermarket_p) + + hash['SmallOffice'] = { aspect_ratio: 1.5, wwr: 0.15, typical_story: 10.0, perim_mult: 1.0 } + hash['MediumOffice'] = { aspect_ratio: 1.5, wwr: 0.33, typical_story: 13.0, perim_mult: 1.0 } + hash['LargeOffice'] = { aspect_ratio: 1.5, wwr: 0.15, typical_story: 13.0, perim_mult: 1.0 } + hash['RetailStandalone'] = { aspect_ratio: 1.28, wwr: 0.07, typical_story: 20.0, perim_mult: 1.0 } + hash['RetailStripmall'] = { aspect_ratio: 4.0, wwr: 0.11, typical_story: 17.0, perim_mult: 1.0 } + hash['PrimarySchool'] = { aspect_ratio: primary_ns_ew_ratio.round(1), wwr: 0.35, typical_story: 13.0, perim_mult: primary_p_mult.round(3) } + hash['SecondarySchool'] = { aspect_ratio: secondary_ns_ew_ratio.round(1), wwr: 0.33, typical_story: 13.0, perim_mult: secondary_p_mult.round(3) } + hash['Outpatient'] = { aspect_ratio: outpatient_ns_ew_ratio.round(1), wwr: 0.20, typical_story: 10.0, perim_mult: outpatient_p_mult.round(3) } + hash['Hospital'] = { aspect_ratio: 1.33, wwr: 0.16, typical_story: 14.0, perim_mult: 1.0 } + hash['SmallHotel'] = { aspect_ratio: 3.0, wwr: 0.11, typical_story: 9.0, first_story: 11.0, perim_mult: 1.0 } + hash['LargeHotel'] = { aspect_ratio: 5.1, wwr: 0.27, typical_story: 10.0, first_story: 13.0, perim_mult: 1.0 } + + # code in get_space_types_from_building_type is used to override building wwr with space type specific wwr + hash['Warehouse'] = { aspect_ratio: 2.2, wwr: 0.0, typical_story: 28.0, perim_mult: 1.0 } + + hash['QuickServiceRestaurant'] = { aspect_ratio: 1.0, wwr: 0.14, typical_story: 10.0, perim_mult: 1.0 } + hash['FullServiceRestaurant'] = { aspect_ratio: 1.0, wwr: 0.18, typical_story: 10.0, perim_mult: 1.0 } + hash['QuickServiceRestaurant'] = { aspect_ratio: 1.0, wwr: 0.18, typical_story: 10.0, perim_mult: 1.0 } + hash['MidriseApartment'] = { aspect_ratio: 2.75, wwr: 0.15, typical_story: 10.0, perim_mult: 1.0 } + hash['HighriseApartment'] = { aspect_ratio: 2.75, wwr: 0.15, typical_story: 10.0, perim_mult: 1.0 } + # SuperMarket inputs come from prototype model + hash['SuperMarket'] = { aspect_ratio: supermarket_aspect_ratio.round(1), wwr: supermarket_wwr.round(2), typical_story: 20.0, perim_mult: 1.0 } + + # Add Laboratory and Data Centers + hash['Laboratory'] = { aspect_ratio: 1.33, wwr: 0.12, typical_story: 10.0, perim_mult: 1.0 } + hash['LargeDataCenterLowITE'] = { aspect_ratio: 1.67, wwr: 0.0, typical_story: 14.0, perim_mult: 1.0 } + hash['LargeDataCenterHighITE'] = { aspect_ratio: 1.67, wwr: 0.0, typical_story: 14.0, perim_mult: 1.0 } + hash['SmallDataCenterLowITE'] = { aspect_ratio: 1.5, wwr: 0.0, typical_story: 14.0, perim_mult: 1.0 } + hash['SmallDataCenterHighITE'] = { aspect_ratio: 1.5, wwr: 0.0, typical_story: 14.0, perim_mult: 1.0 } + + # Add Courthouse and Education + hash['Courthouse'] = { aspect_ratio: 2.06, wwr: 0.18, typical_story: 16.0, perim_mult: 1.0 } + hash['College'] = { aspect_ratio: 2.5, wwr: 0.037, typical_story: 13.0, perim_mult: 1.0 } + + # DEER Prototypes + hash['Asm'] = { aspect_ratio: 1.0, wwr: 0.19, typical_story: 15.0 } + hash['ECC'] = { aspect_ratio: 4.0, wwr: 0.25, typical_story: 13.0 } + hash['EPr'] = { aspect_ratio: 2.0, wwr: 0.16, typical_story: 12.0 } + hash['ERC'] = { aspect_ratio: 1.7, wwr: 0.03, typical_story: 12.0 } + hash['ESe'] = { aspect_ratio: 1.0, wwr: 0.15, typical_story: 13.0 } + hash['EUn'] = { aspect_ratio: 2.5, wwr: 0.3, typical_story: 14.0 } + hash['Gro'] = { aspect_ratio: 1.0, wwr: 0.07, typical_story: 25.0 } + hash['Hsp'] = { aspect_ratio: 1.5, wwr: 0.11, typical_story: 13.0 } + hash['Htl'] = { aspect_ratio: 3.0, wwr: 0.23, typical_story: 9.5, first_story: 12.0 } + hash['MBT'] = { aspect_ratio: 10.7, wwr: 0.12, typical_story: 15.0 } + hash['MFm'] = { aspect_ratio: 1.4, wwr: 0.24, typical_story: 9.5 } + hash['MLI'] = { aspect_ratio: 1.0, wwr: 0.01, typical_story: 35.0 } + hash['Mtl'] = { aspect_ratio: 5.1, wwr: 0.41, typical_story: 9.0 } + hash['Nrs'] = { aspect_ratio: 10.3, wwr: 0.2, typical_story: 13.0 } + hash['OfL'] = { aspect_ratio: 1.5, wwr: 0.33, typical_story: 12.0 } + hash['OfS'] = { aspect_ratio: 1.5, wwr: 0.33, typical_story: 12.0 } + hash['RFF'] = { aspect_ratio: 1.0, wwr: 0.25, typical_story: 13.0 } + hash['RSD'] = { aspect_ratio: 1.0, wwr: 0.13, typical_story: 13.0 } + hash['Rt3'] = { aspect_ratio: 1.0, wwr: 0.02, typical_story: 20.8 } + hash['RtL'] = { aspect_ratio: 1.0, wwr: 0.03, typical_story: 20.5 } + hash['RtS'] = { aspect_ratio: 1.0, wwr: 0.13, typical_story: 12.0 } + hash['SCn'] = { aspect_ratio: 1.0, wwr: 0.01, typical_story: 48.0 } + hash['SUn'] = { aspect_ratio: 1.0, wwr: 0.01, typical_story: 48.0 } + hash['WRf'] = { aspect_ratio: 1.6, wwr: 0.0, typical_story: 32.0 } + + return hash[building_type] + end + + # get length and width of rectangle matching bounding box aspect ratio will maintaining proper floor area + # + # @param envelope_data_hash [Hash] Hash of envelope data including building_max_xyz and effective__num_stories + # @return [Hash] hash of bar length and width + def self.calc_bar_reduced_bounding_box(envelope_data_hash) + bar = {} + + bounding_length = envelope_data_hash[:building_max_xyz][0] - envelope_data_hash[:building_min_xyz][0] + bounding_width = envelope_data_hash[:building_max_xyz][1] - envelope_data_hash[:building_min_xyz][1] + bounding_area = bounding_length * bounding_width + footprint_area = envelope_data_hash[:building_floor_area] / envelope_data_hash[:effective__num_stories].to_f + area_multiplier = footprint_area / bounding_area + edge_multiplier = Math.sqrt(area_multiplier) + bar[:length] = bounding_length * edge_multiplier + bar[:width] = bounding_width * edge_multiplier + + return bar + end + + # get length and width of rectangle matching longer of two edges, and reducing the other way until floor area matches + # + # @param envelope_data_hash [Hash] Hash of envelope data including building_max_xyz and effective__num_stories + # @return [Hash] hash of bar length and width + def self.calc_bar_reduced_width(envelope_data_hash) + bar = {} + + bounding_length = envelope_data_hash[:building_max_xyz][0] - envelope_data_hash[:building_min_xyz][0] + bounding_width = envelope_data_hash[:building_max_xyz][1] - envelope_data_hash[:building_min_xyz][1] + footprint_area = envelope_data_hash[:building_floor_area] / envelope_data_hash[:effective__num_stories].to_f + + if bounding_length >= bounding_width + bar[:length] = bounding_length + bar[:width] = footprint_area / bounding_length + else + bar[:width] = bounding_width + bar[:length] = footprint_area / bounding_width + end + + return bar + end + + # get length and width of rectangle by stretching it until both floor area and exterior wall area or perimeter match + # + # @param envelope_data_hash [Hash] Hash of envelope data including building_max_xyz and effective__num_stories + # @return [Hash] hash of bar length and width + def self.calc_bar_stretched(envelope_data_hash) + bar = {} + + bounding_length = envelope_data_hash[:building_max_xyz][0] - envelope_data_hash[:building_min_xyz][0] + bounding_width = envelope_data_hash[:building_max_xyz][1] - envelope_data_hash[:building_min_xyz][1] + a = envelope_data_hash[:building_floor_area] / envelope_data_hash[:effective__num_stories].to_f + p = envelope_data_hash[:building_perimeter] + + if bounding_length >= bounding_width + bar[:length] = 0.25 * (p + Math.sqrt(p**2 - 16 * a)) + bar[:width] = 0.25 * (p - Math.sqrt(p**2 - 16 * a)) + else + bar[:length] = 0.25 * (p - Math.sqrt(p**2 - 16 * a)) + bar[:width] = 0.25 * (p + Math.sqrt(p**2 - 16 * a)) + end + + return bar + end + + # create_bar(runner,model,bar_hash) + # measures using this method should include OsLibGeometry and OsLibHelperMethods + def self.create_bar(runner, model, bar_hash, story_multiplier_method = 'Basements Ground Mid Top') + # warn about site shading + if !model.getSite.shadingSurfaceGroups.empty? + runner.registerWarning('The model has one or more site shading surafces. New geometry may not be positioned where expected, it will be centered over the center of the original geometry.') + end + + # make custom story hash when number of stories below grade > 0 + # todo - update this so have option basements are not below 0? (useful for simplifying existing model and maintaining z position relative to site shading) + story_hash = {} + eff_below = bar_hash[:num_stories_below_grade] + eff_above = bar_hash[:num_stories_above_grade] + footprint_origin = bar_hash[:center_of_footprint] + typical_story_height = bar_hash[:floor_height] + + # flatten story_hash out to individual stories included in building area + stories_flat = [] + stories_flat_counter = 0 + bar_hash[:stories].each_with_index do |(k, v), i| + # k is invalid in some cases, old story object that has been removed, should be from low to high including basement + # skip if source story insn't included in building area + if v[:story_included_in_building_area].nil? || (v[:story_included_in_building_area] == true) + + # add to counter + stories_flat_counter += v[:story_min_multiplier] + + flat_hash = {} + flat_hash[:story_party_walls] = v[:story_party_walls] + flat_hash[:below_partial_story] = v[:below_partial_story] + flat_hash[:bottom_story_ground_exposed_floor] = v[:bottom_story_ground_exposed_floor] + flat_hash[:top_story_exterior_exposed_roof] = v[:top_story_exterior_exposed_roof] + if i < eff_below + flat_hash[:story_type] = 'B' + flat_hash[:multiplier] = 1 + elsif i == eff_below + flat_hash[:story_type] = 'Ground' + flat_hash[:multiplier] = 1 + elsif stories_flat_counter == eff_below + eff_above.ceil + flat_hash[:story_type] = 'Top' + flat_hash[:multiplier] = 1 + else + flat_hash[:story_type] = 'Mid' + flat_hash[:multiplier] = v[:story_min_multiplier] + end + + compare_hash = {} + if !stories_flat.empty? + stories_flat.last.each { |k, v| compare_hash[k] = flat_hash[k] if flat_hash[k] != v } + end + if (story_multiplier_method != 'None' && stories_flat.last == flat_hash) || (story_multiplier_method != 'None' && compare_hash.size == 1 && compare_hash.include?(:multiplier)) + stories_flat.last[:multiplier] += v[:story_min_multiplier] + else + stories_flat << flat_hash + end + end + end + + if bar_hash[:num_stories_below_grade] > 0 + + # add in below grade levels (may want to add below grade multipliers at some point if we start running deep basements) + eff_below.times do |i| + story_hash["B#{i + 1}"] = { space_origin_z: footprint_origin.z - typical_story_height * (i + 1), space_height: typical_story_height, multiplier: 1 } + end + end + + # add in above grade levels + if eff_above > 2 + story_hash['Ground'] = { space_origin_z: footprint_origin.z, space_height: typical_story_height, multiplier: 1 } + + footprint_counter = 0 + effective_stories_counter = 1 + stories_flat.each do |hash| + next if hash[:story_type] != 'Mid' + if footprint_counter == 0 + string = 'Mid' + else + string = "Mid#{footprint_counter + 1}" + end + story_hash[string] = { space_origin_z: footprint_origin.z + typical_story_height * effective_stories_counter + typical_story_height * (hash[:multiplier] - 1) / 2.0, space_height: typical_story_height, multiplier: hash[:multiplier] } + footprint_counter += 1 + effective_stories_counter += hash[:multiplier] + end + + story_hash['Top'] = { space_origin_z: footprint_origin.z + typical_story_height * (eff_above.ceil - 1), space_height: typical_story_height, multiplier: 1 } + elsif eff_above > 1 + story_hash['Ground'] = { space_origin_z: footprint_origin.z, space_height: typical_story_height, multiplier: 1 } + story_hash['Top'] = { space_origin_z: footprint_origin.z + typical_story_height * (eff_above.ceil - 1), space_height: typical_story_height, multiplier: 1 } + else # one story only + story_hash['Ground'] = { space_origin_z: footprint_origin.z, space_height: typical_story_height, multiplier: 1 } + end + + # create footprints + if bar_hash[:bar_division_method] == 'Multiple Space Types - Simple Sliced' + footprints = [] + story_hash.size.times do |i| + # adjust size of bar of top story is not a full story + if i + 1 == story_hash.size + area_multiplier = (1.0 - bar_hash[:num_stories_above_grade].ceil + bar_hash[:num_stories_above_grade]) + edge_multiplier = Math.sqrt(area_multiplier) + length = bar_hash[:length] * edge_multiplier + width = bar_hash[:width] * edge_multiplier + else + length = bar_hash[:length] + width = bar_hash[:width] + end + footprints << OsLib_Geometry.make_sliced_bar_simple_polygons(runner, bar_hash[:space_types], length, width, bar_hash[:center_of_footprint]) + end + + elsif bar_hash[:bar_division_method] == 'Multiple Space Types - Individual Stories Sliced' + + # update story_hash for partial_story_above + story_hash.each_with_index do |(k, v), i| + # adjust size of bar of top story is not a full story + if i + 1 == story_hash.size + story_hash[k][:partial_story_multiplier] = (1.0 - bar_hash[:num_stories_above_grade].ceil + bar_hash[:num_stories_above_grade]) + end + end + + footprints = OsLib_Geometry.make_sliced_bar_multi_polygons(runner, bar_hash[:space_types], bar_hash[:length], bar_hash[:width], bar_hash[:center_of_footprint], story_hash) + + else + footprints = [] + story_hash.size.times do |i| + # adjust size of bar of top story is not a full story + if i + 1 == story_hash.size + area_multiplier = (1.0 - bar_hash[:num_stories_above_grade].ceil + bar_hash[:num_stories_above_grade]) + edge_multiplier = Math.sqrt(area_multiplier) + length = bar_hash[:length] * edge_multiplier + width = bar_hash[:width] * edge_multiplier + else + length = bar_hash[:length] + width = bar_hash[:width] + end + footprints << OsLib_Geometry.make_core_and_perimeter_polygons(runner, length, width, bar_hash[:center_of_footprint]) # perimeter defaults to 15' + end + + # set primary space type to building default space type + space_types = bar_hash[:space_types].sort_by { |k, v| v[:floor_area] } + if space_types.last.first.class.to_s == 'OpenStudio::Model::SpaceType' + model.getBuilding.setSpaceType(space_types.last.first) + end + + end + + # makeSpacesFromPolygons + new_spaces = OsLib_Geometry.makeSpacesFromPolygons(runner, model, footprints, bar_hash[:floor_height], bar_hash[:num_stories], bar_hash[:center_of_footprint], story_hash) + + # put all of the spaces in the model into a vector for intersection and surface matching + spaces = OpenStudio::Model::SpaceVector.new + model.getSpaces.sort.each do |space| + spaces << space + end + + # flag for intersection and matching type + diagnostic_intersect = true + + # only intersect if make_mid_story_surfaces_adiabatic false + if diagnostic_intersect + + model.getPlanarSurfaces.sort.each do |surface| + array = [] + vertices = surface.vertices + fixed = false + vertices.each do |vertex| + next if fixed + if array.include?(vertex) + # create a new set of vertices + new_vertices = OpenStudio::Point3dVector.new + array_b = [] + surface.vertices.each do |vertex_b| + next if array_b.include?(vertex_b) + new_vertices << vertex_b + array_b << vertex_b + end + surface.setVertices(new_vertices) + num_removed = vertices.size - surface.vertices.size + runner.registerWarning("#{surface.name} has duplicate vertices. Started with #{vertices.size} vertices, removed #{num_removed}.") + fixed = true + else + array << vertex + end + end + end + + # remove collinear points in a surface + model.getPlanarSurfaces.sort.each do |surface| + new_vertices = OpenStudio.removeCollinear(surface.vertices) + starting_count = surface.vertices.size + final_count = new_vertices.size + if final_count < starting_count + runner.registerWarning("Removing #{starting_count - final_count} collinear vertices from #{surface.name}.") + surface.setVertices(new_vertices) + end + end + + # remove duplicate surfaces in a space (should be done after remove duplicate and collinear points) + model.getSpaces.sort.each do |space| + # secondary array to compare against + surfaces_b = space.surfaces.sort + + space.surfaces.sort.each do |surface_a| + # delete from secondary array + surfaces_b.delete(surface_a) + + surfaces_b.each do |surface_b| + next if surface_a == surface_b # dont' test against same surface + if surface_a.equalVertices(surface_b) + runner.registerWarning("#{surface_a.name} and #{surface_b.name} in #{space.name} have duplicate geometry, removing #{surface_b.name}.") + surface_b.remove + elsif surface_a.reverseEqualVertices(surface_b) + # TODO: - add logic to determine which face naormal is reversed and which is correct + runner.registerWarning("#{surface_a.name} and #{surface_b.name} in #{space.name} have reversed geometry, removing #{surface_b.name}.") + surface_b.remove + end + end + end + end + + if !(bar_hash[:make_mid_story_surfaces_adiabatic]) + # intersect and surface match two pair by pair + spaces_b = model.getSpaces.sort + # looping through vector of each space + model.getSpaces.sort.each do |space_a| + spaces_b.delete(space_a) + spaces_b.each do |space_b| + # runner.registerInfo("Intersecting and matching surfaces between #{space_a.name} and #{space.name}") + spaces_temp = OpenStudio::Model::SpaceVector.new + spaces_temp << space_a + spaces_temp << space_b + # intersect and sort + OpenStudio::Model.intersectSurfaces(spaces_temp) + OpenStudio::Model.matchSurfaces(spaces_temp) + end + end + runner.registerInfo('Intersecting and matching surfaces in model, this will create additional geometry.') + else # elsif bar_hash[:double_loaded_corridor] # only intersect spaces in each story, not between wtory + model.getBuilding.buildingStories.sort.each do |story| + # intersect and surface match two pair by pair + spaces_b = story.spaces.sort + # looping through vector of each space + story.spaces.sort.each do |space_a| + spaces_b.delete(space_a) + spaces_b.each do |space_b| + spaces_temp = OpenStudio::Model::SpaceVector.new + spaces_temp << space_a + spaces_temp << space_b + # attempt to intersect and match walls on a story, but later secondary match will look for missted matches and turn them to adiabaitc + # intersect and sort + OpenStudio::Model.intersectSurfaces(spaces_temp) + OpenStudio::Model.matchSurfaces(spaces_temp) + end + end + runner.registerInfo("Intersecting and matching surfaces in story #{story.name}, this will create additional geometry. Diagnstoic intersection and matching done a in paris of spaces.") + end + end + + else + + if !(bar_hash[:make_mid_story_surfaces_adiabatic]) + # intersect surfaces + # (when bottom floor has many space types and one above doesn't will end up with heavily subdivided floor. Maybe use adiabatic and don't intersect floor/ceilings) + intersect_surfaces = true + if intersect_surfaces + OpenStudio::Model.intersectSurfaces(spaces) + OpenStudio::Model.matchSurfaces(spaces) + runner.registerInfo('Intersecting and matching surfaces in model, this will create additional geometry.') + end + else # elsif bar_hash[:double_loaded_corridor] # only intersect spaces in each story, not between wtory + model.getBuilding.buildingStories.sort.each do |story| + story_spaces = OpenStudio::Model::SpaceVector.new + story.spaces.sort.each do |space| + story_spaces << space + end + # attempt to intersect and match walls on a story, but later secondary match will look for missted matches and turn them to adiabaitc + # intersect and sort + OpenStudio::Model.intersectSurfaces(story_spaces) + OpenStudio::Model.matchSurfaces(story_spaces) + runner.registerInfo("Intersecting and matching surfaces in story #{story.name}, this will create additional geometry.") + end + end + + end + + # set boundary conditions if not already set when geometry was created + # todo - update this to use space original z value vs. story name + if bar_hash[:num_stories_below_grade] > 0 + model.getBuildingStorys.sort.each do |story| + next if !story.name.to_s.include?('Story B') + story.spaces.sort.each do |space| + next if !new_spaces.include?(space) + space.surfaces.sort.each do |surface| + next if surface.surfaceType != 'Wall' + next if surface.outsideBoundaryCondition != 'Outdoors' + surface.setOutsideBoundaryCondition('Ground') + end + end + end + end + + # set wall boundary condtions to adiabatic if using make_mid_story_surfaces_adiabatic prior to windows being made + if bar_hash[:make_mid_story_surfaces_adiabatic] + + runner.registerInfo("Finding non-exterior walls and setting boundary condition to adiabatic") + + # need to organize by story incase top story is partial story + # should also be only for a single bar + story_bounding = {} + missed_match_count = 0 + + # gather new spaces by story + new_spaces.each do |space| + story = space.buildingStory.get + if story_bounding.has_key?(story) + story_bounding[story][:spaces] << space + else + story_bounding[story] = {:spaces => [space]} + end + end + + # get bounding box for each story + story_bounding.each do |story,v| + + # get bounding_box + bounding_box = OpenStudio::BoundingBox.new + v[:spaces].each do |space| + space.surfaces.each do |space_surface| + bounding_box.addPoints(space.transformation * space_surface.vertices) + end + end + min_x = bounding_box.minX.get + min_y = bounding_box.minY.get + max_x = bounding_box.maxX.get + max_y = bounding_box.maxY.get + ext_wall_toll = 0.01 + + # check surfaces again against min/max and change to adiabatic if not fully on one min or max x or y + # todo - may need to look at aidiabiatc constructions in downstream measure. Some may be exterior party wall others may be interior walls + v[:spaces].each do |space| + space.surfaces.each do |space_surface| + next if not space_surface.surfaceType == "Wall" + next if space_surface.outsideBoundaryCondition == "Surface" # if if found a match leave it alone, don't change to adiabiatc + surface_bounding_box = OpenStudio::BoundingBox.new + surface_bounding_box.addPoints(space.transformation * space_surface.vertices) + surface_on_outside = false + # check xmin + if (surface_bounding_box.minX.get - min_x).abs < ext_wall_toll && (surface_bounding_box.maxX.get - min_x).abs < ext_wall_toll then surface_on_outside = true end + # check xmax + if (surface_bounding_box.minX.get - max_x).abs < ext_wall_toll && (surface_bounding_box.maxX.get - max_x).abs < ext_wall_toll then surface_on_outside = true end + # check ymin + if (surface_bounding_box.minY.get - min_y).abs < ext_wall_toll && (surface_bounding_box.maxY.get - min_y).abs < ext_wall_toll then surface_on_outside = true end + # check ymax + if (surface_bounding_box.minY.get - max_y).abs < ext_wall_toll && (surface_bounding_box.maxY.get - max_y).abs < ext_wall_toll then surface_on_outside = true end + + # change if not exterior + if !surface_on_outside + space_surface.setOutsideBoundaryCondition("Adiabatic") + missed_match_count += 1 + end + end + end + end + + if missed_match_count > 0 + runner.registerInfo("#{missed_match_count} surfaces that were exterior appear to be interior walls and had boundary condition chagned to adiabiatic.") + end + + end + + # sort stories (by name for now but need better way) + sorted_stories = {} + new_spaces.each do |space| + next if !space.buildingStory.is_initialized + story = space.buildingStory.get + if !sorted_stories.key?(name.to_s) + sorted_stories[story.name.to_s] = story + end + end + + # flag space types that have wwr overrides + space_type_wwr_overrides = {} + + # loop through building stories, spaces, and surfaces + sorted_stories.sort.each_with_index do |(key, story), i| + # flag for adiabatic floor if building doesn't have ground exposed floor + if stories_flat[i][:bottom_story_ground_exposed_floor] == false + adiabatic_floor = true + end + # flag for adiabatic roof if building doesn't have exterior exposed roof + if stories_flat[i][:top_story_exterior_exposed_roof] == false + adiabatic_ceiling = true + end + + # make all mid story floor and ceilings adiabatic if requested + if bar_hash[:make_mid_story_surfaces_adiabatic] + if i > 0 + adiabatic_floor = true + end + if i < sorted_stories.size - 1 + adiabatic_ceiling = true + end + end + + # flag orientations for this story to recieve party walls + party_wall_facades = stories_flat[i][:story_party_walls] + + story.spaces.each do |space| + next if !new_spaces.include?(space) + space.surfaces. each do |surface| + # set floor to adiabatic if requited + if adiabatic_floor && surface.surfaceType == 'Floor' + make_surfaces_adiabatic([surface]) + elsif adiabatic_ceiling && surface.surfaceType == 'RoofCeiling' + make_surfaces_adiabatic([surface]) + end + + # skip of not exterior wall + next if surface.surfaceType != 'Wall' + next if surface.outsideBoundaryCondition != 'Outdoors' + + # get the absoluteAzimuth for the surface so we can categorize it + absoluteAzimuth = OpenStudio.convert(surface.azimuth, 'rad', 'deg').get + surface.space.get.directionofRelativeNorth + model.getBuilding.northAxis + absoluteAzimuth = absoluteAzimuth % 360.0 # should result in value between 0 and 360 + absoluteAzimuth = absoluteAzimuth.round(5) # this was creating issues at 45 deg angles with opposing facades + + # target wwr values that may be changed for specific space types + wwr_n = bar_hash[:building_wwr_n] + wwr_e = bar_hash[:building_wwr_e] + wwr_s = bar_hash[:building_wwr_s] + wwr_w = bar_hash[:building_wwr_w] + + # look for space type specific wwr values + if surface.space.is_initialized && surface.space.get.spaceType.is_initialized + space_type = surface.space.get.spaceType.get + + # see if space type has wwr value + bar_hash[:space_types].each do |k, v| + if v.key?(:space_type) && space_type == v[:space_type] + + # if matching space type specifies a wwr then override the orientation specific recommendations for this surface. + if v.key?(:wwr) + wwr_n = v[:wwr] + wwr_e = v[:wwr] + wwr_s = v[:wwr] + wwr_w = v[:wwr] + space_type_wwr_overrides[space_type] = v[:wwr] + end + end + end + end + + # add fenestration (wwr for now, maybe overhang and overhead doors later) + if (absoluteAzimuth >= 315.0) || (absoluteAzimuth < 45.0) + if party_wall_facades.include?('north') + make_surfaces_adiabatic([surface]) + else + surface.setWindowToWallRatio(wwr_n) + end + elsif (absoluteAzimuth >= 45.0) && (absoluteAzimuth < 135.0) + if party_wall_facades.include?('east') + make_surfaces_adiabatic([surface]) + else + surface.setWindowToWallRatio(wwr_e) + end + elsif (absoluteAzimuth >= 135.0) && (absoluteAzimuth < 225.0) + if party_wall_facades.include?('south') + make_surfaces_adiabatic([surface]) + else + surface.setWindowToWallRatio(wwr_s) + end + elsif (absoluteAzimuth >= 225.0) && (absoluteAzimuth < 315.0) + if party_wall_facades.include?('west') + make_surfaces_adiabatic([surface]) + else + surface.setWindowToWallRatio(wwr_w) + end + else + runner.registerError('Unexpected value of facade: ' + absoluteAzimuth + '.') + return false + end + end + end + end + + # report space types with custom wwr values + space_type_wwr_overrides.each do |space_type, wwr| + runner.registerInfo("For #{space_type.name} the default building wwr was replaced with a space type specfic value of #{wwr}") + end + + new_floor_area_si = 0.0 + new_spaces.each do |space| + new_floor_area_si += space.floorArea * space.multiplier + end + new_floor_area_ip = OpenStudio.convert(new_floor_area_si, 'm^2', 'ft^2').get + + final_floor_area_ip = OpenStudio.convert(model.getBuilding.floorArea, 'm^2', 'ft^2').get + if new_floor_area_ip == final_floor_area_ip + runner.registerInfo("Created bar envelope with floor area of #{OpenStudio.toNeatString(new_floor_area_ip, 0, true)} ft^2.") + else + runner.registerInfo("Created bar envelope with floor area of #{OpenStudio.toNeatString(new_floor_area_ip, 0, true)} ft^2. Total building area is #{OpenStudio.toNeatString(final_floor_area_ip, 0, true)} ft^2.") + end + + return new_spaces + end + + def self.bar_hash_setup_run(runner, model, args, length, width, floor_height_si, center_of_footprint, space_types_hash, num_stories) + # create envelope + # populate bar_hash and create envelope with data from envelope_data_hash and user arguments + bar_hash = {} + bar_hash[:length] = length + bar_hash[:width] = width + bar_hash[:num_stories_below_grade] = args['num_stories_below_grade'] + bar_hash[:num_stories_above_grade] = args['num_stories_above_grade'] + bar_hash[:floor_height] = floor_height_si + bar_hash[:center_of_footprint] = center_of_footprint + bar_hash[:bar_division_method] = args['bar_division_method'] + bar_hash[:make_mid_story_surfaces_adiabatic] = args['make_mid_story_surfaces_adiabatic'] + bar_hash[:space_types] = space_types_hash + bar_hash[:building_wwr_n] = args['wwr'] + bar_hash[:building_wwr_s] = args['wwr'] + bar_hash[:building_wwr_e] = args['wwr'] + bar_hash[:building_wwr_w] = args['wwr'] + + # round up non integer stoires to next integer + num_stories_round_up = num_stories.ceil + runner.registerInfo("Making bar with length of #{OpenStudio.toNeatString(OpenStudio.convert(length, 'm', 'ft').get, 0, true)} ft and width of #{OpenStudio.toNeatString(OpenStudio.convert(width, 'm', 'ft').get, 0, true)} ft") + + # party_walls_array to be used by orientation specific or fractional party wall values + party_walls_array = [] # this is an array of arrays, where each entry is effective building story with array of directions + + if args['party_wall_stories_north'] + args['party_wall_stories_south'] + args['party_wall_stories_east'] + args['party_wall_stories_west'] > 0 + + # loop through effective number of stories add orientation specific party walls per user arguments + num_stories_round_up.times do |i| + test_value = i + 1 - bar_hash[:num_stories_below_grade] + + array = [] + if args['party_wall_stories_north'] >= test_value + array << 'north' + end + if args['party_wall_stories_south'] >= test_value + array << 'south' + end + if args['party_wall_stories_east'] >= test_value + array << 'east' + end + if args['party_wall_stories_west'] >= test_value + array << 'west' + end + + # populate party_wall_array for this story + party_walls_array << array + end + end + + # calculate party walls if using party_wall_fraction method + if args['party_wall_fraction'] > 0 && !party_walls_array.empty? + runner.registerWarning('Both orientation and fractional party wall values arguments were populated, will ignore fractional party wall input') + elsif args['party_wall_fraction'] > 0 + + # orientation of long and short side of building will vary based on building rotation + + # full story ext wall area + typical_length_facade_area = length * floor_height_si + typical_width_facade_area = width * floor_height_si + + # top story ext wall area, may be partial story + partial_story_multiplier = (1.0 - args['num_stories_above_grade'].ceil + args['num_stories_above_grade']) + area_multiplier = partial_story_multiplier + edge_multiplier = Math.sqrt(area_multiplier) + top_story_length = length * edge_multiplier + top_story_width = width * edge_multiplier + top_story_length_facade_area = top_story_length * floor_height_si + top_story_width_facade_area = top_story_width * floor_height_si + + total_exterior_wall_area = 2 * (length + width) * (args['num_stories_above_grade'].ceil - 1.0) * floor_height_si + 2 * (top_story_length + top_story_width) * floor_height_si + target_party_wall_area = total_exterior_wall_area * args['party_wall_fraction'] + + width_counter = 0 + width_area = 0.0 + facade_area = typical_width_facade_area + until (width_area + facade_area >= target_party_wall_area) || (width_counter == args['num_stories_above_grade'].ceil * 2) + # update facade area for top story + if width_counter == args['num_stories_above_grade'].ceil - 1 || width_counter == args['num_stories_above_grade'].ceil * 2 - 1 + facade_area = top_story_width_facade_area + else + facade_area = typical_width_facade_area + end + + width_counter += 1 + width_area += facade_area + + end + width_area_remainder = target_party_wall_area - width_area + + length_counter = 0 + length_area = 0.0 + facade_area = typical_length_facade_area + until (length_area + facade_area >= target_party_wall_area) || (length_counter == args['num_stories_above_grade'].ceil * 2) + # update facade area for top story + if length_counter == args['num_stories_above_grade'].ceil - 1 || length_counter == args['num_stories_above_grade'].ceil * 2 - 1 + facade_area = top_story_length_facade_area + else + facade_area = typical_length_facade_area + end + + length_counter += 1 + length_area += facade_area + end + length_area_remainder = target_party_wall_area - length_area + + # get rotation and best fit to adjust orientation for fraction party wall + rotation = args['building_rotation'] % 360.0 # should result in value between 0 and 360 + card_dir_array = [0.0, 90.0, 180.0, 270.0, 360.0] + # reverse array to properly handle 45, 135, 225, and 315 + best_fit = card_dir_array.reverse.min_by { |x| (x.to_f - rotation).abs } + + if ![90.0, 270.0].include? best_fit + width_card_dir = ['east', 'west'] + length_card_dir = ['north', 'south'] + else # if rotation is closest to 90 or 270 then reverse which orientation is used for length and width + width_card_dir = ['north', 'south'] + length_card_dir = ['east', 'west'] + end + + # if dont' find enough on short sides + if width_area_remainder <= typical_length_facade_area + + num_stories_round_up.times do |i| + if i + 1 <= args['num_stories_below_grade'] + party_walls_array << [] + next + end + if i + 1 - args['num_stories_below_grade'] <= width_counter + if i + 1 - args['num_stories_below_grade'] <= width_counter - args['num_stories_above_grade'] + party_walls_array << width_card_dir + else + party_walls_array << [width_card_dir.first] + end + else + party_walls_array << [] + end + end + + else # use long sides instead + + num_stories_round_up.times do |i| + if i + 1 <= args['num_stories_below_grade'] + party_walls_array << [] + next + end + if i + 1 - args['num_stories_below_grade'] <= length_counter + if i + 1 - args['num_stories_below_grade'] <= length_counter - args['num_stories_above_grade'] + party_walls_array << length_card_dir + else + party_walls_array << [length_card_dir.first] + end + else + party_walls_array << [] + end + end + + end + + # TODO: - currently won't go past making two opposing sets of walls party walls. Info and registerValue are after create_bar in measure.rb + + end + + # populate bar hash with story information + bar_hash[:stories] = {} + num_stories_round_up.times do |i| + if party_walls_array.empty? + party_walls = [] + else + party_walls = party_walls_array[i] + end + + # add below_partial_story + if num_stories.ceil > num_stories && i == num_stories_round_up - 2 + below_partial_story = true + else + below_partial_story = false + end + + # bottom_story_ground_exposed_floor and top_story_exterior_exposed_roof already setup as bool + bar_hash[:stories]["key #{i}"] = { story_party_walls: party_walls, story_min_multiplier: 1, story_included_in_building_area: true, below_partial_story: below_partial_story, bottom_story_ground_exposed_floor: args['bottom_story_ground_exposed_floor'], top_story_exterior_exposed_roof: args['top_story_exterior_exposed_roof'] } + end + + # create bar + new_spaces = create_bar(runner, model, bar_hash, args['story_multiplier']) + + # check expect roof and wall area + target_footprint = bar_hash[:length] * bar_hash[:width] + ground_floor_area = 0.0 + roof_area = 0.0 + new_spaces.each do |space| + space.surfaces.each do |surface| + if surface.surfaceType == 'Floor' && surface.outsideBoundaryCondition == 'Ground' + ground_floor_area += surface.netArea + elsif surface.surfaceType == 'RoofCeiling' && surface.outsideBoundaryCondition == 'Outdoors' + roof_area += surface.netArea + end + end + end + # TODO: - extend to address when top and or bottom story are not exposed via argument + if ground_floor_area > target_footprint + 0.001 || roof_area > target_footprint + 0.001 + # runner.registerError("Ground exposed floor or Roof area is larger than footprint, likely inter-floor surface matching and intersection error.") + # return false + + # not providing adiabatic work around when top story is partial story. + if args['num_stories_above_grade'].to_f != args['num_stories_above_grade'].ceil + runner.registerError('Ground exposed floor or Roof area is larger than footprint, likely inter-floor surface matching and intersection error.') + return false + else + runner.registerInfo('Ground exposed floor or Roof area is larger than footprint, likely inter-floor surface matching and intersection error, altering impacted surfaces boundary condition to be adiabatic.') + match_error = true + end + else + match_error = false + end + + # TODO: - should be able to remove this fix after OpenStudio intersection issue is fixed. At that time turn the above message into an error with return false after it + if match_error + + # identify z value of top and bottom story + bottom_story = nil + top_story = nil + new_spaces.each do |space| + story = space.buildingStory.get + nom_z = story.nominalZCoordinate.get + if bottom_story.nil? + bottom_story = nom_z + elsif bottom_story > nom_z + bottom_story = nom_z + end + if top_story.nil? + top_story = nom_z + elsif top_story < nom_z + top_story = nom_z + end + end + + # change boundary condition and intersection as needed. + new_spaces.each do |space| + if space.buildingStory.get.nominalZCoordinate.get > bottom_story + # change floors + space.surfaces.each do |surface| + next if !(surface.surfaceType == 'Floor' && surface.outsideBoundaryCondition == 'Ground') + surface.setOutsideBoundaryCondition('Adiabatic') + end + end + if space.buildingStory.get.nominalZCoordinate.get < top_story + # change ceilings + space.surfaces.each do |surface| + next if !(surface.surfaceType == 'RoofCeiling' && surface.outsideBoundaryCondition == 'Outdoors') + surface.setOutsideBoundaryCondition('Adiabatic') + end + end + end + end + end + + # bar_arg_check_setup + def self.bar_arg_check_setup(model, runner, user_arguments, building_type_ratios = true) + + # assign the user inputs to variables + args = OsLib_HelperMethods.createRunVariables(runner, model, user_arguments, arguments(model)) + if !args then return false end + + # add in arguments that may not be passed in + if !args.key?('double_loaded_corridor') + args['double_loaded_corridor'] = 'None' # use None when not in measure building type data may not contain this + end + if !args.key?('perim_mult') + args['perim_mult'] = 1.0 # will not make two bars for extended perimeter + end + + # lookup and replace argument values from upstream measures + if args['use_upstream_args'] == true + args.each do |arg, value| + next if arg == 'use_upstream_args' # this argument should not be changed + value_from_osw = OsLib_HelperMethods.check_upstream_measure_for_arg(runner, arg) + if !value_from_osw.empty? + runner.registerInfo("Replacing argument named #{arg} from current measure with a value of #{value_from_osw[:value]} from #{value_from_osw[:measure_name]}.") + new_val = value_from_osw[:value] + # TODO: - make code to handle non strings more robust. check_upstream_measure_for_arg could pass back the argument type + if arg == 'total_bldg_floor_area' + args[arg] = new_val.to_f + elsif arg == 'num_stories_above_grade' + args[arg] = new_val.to_f + elsif arg == 'zipcode' + args[arg] = new_val.to_i + else + args[arg] = new_val + end + end + end + end + + # check expected values of double arguments + fraction_args = ['wwr', 'party_wall_fraction'] + if building_type_ratios + fraction_args << 'bldg_type_b_fract_bldg_area' + fraction_args << 'bldg_type_c_fract_bldg_area' + fraction_args << 'bldg_type_d_fract_bldg_area' + end + fraction = OsLib_HelperMethods.checkDoubleAndIntegerArguments(runner, user_arguments, 'min' => 0.0, 'max' => 1.0, 'min_eq_bool' => true, 'max_eq_bool' => true, 'arg_array' => fraction_args) + + one_or_greater_args = ['num_stories_above_grade'] + one_or_greater = OsLib_HelperMethods.checkDoubleAndIntegerArguments(runner, user_arguments, 'min' => 1.0, 'max' => nil, 'min_eq_bool' => true, 'max_eq_bool' => false, 'arg_array' => one_or_greater_args) + + non_neg_args = ['num_stories_below_grade', + 'floor_height', + 'ns_to_ew_ratio', + 'party_wall_stories_north', + 'party_wall_stories_south', + 'party_wall_stories_east', + 'party_wall_stories_west', + 'total_bldg_floor_area', + 'single_floor_area', + 'bar_width'] + non_neg = OsLib_HelperMethods.checkDoubleAndIntegerArguments(runner, user_arguments, 'min' => 0.0, 'max' => nil, 'min_eq_bool' => true, 'max_eq_bool' => false, 'arg_array' => non_neg_args) + + # return false if any errors fail + if !fraction then return false end + return false if !one_or_greater + return false if !non_neg + + return args + + end + + # bar_from_building_type_ratios + # used for varieties of measures that create bar from building type ratios + def self.bar_from_building_type_ratios(model, runner, user_arguments) + + # prep arguments + args = bar_arg_check_setup(model,runner,user_arguments) + if !args then return false end + + # check that sum of fractions for b,c, and d is less than 1.0 (so something is left for primary building type) + bldg_type_a_fract_bldg_area = 1.0 - args['bldg_type_b_fract_bldg_area'] - args['bldg_type_c_fract_bldg_area'] - args['bldg_type_d_fract_bldg_area'] + if bldg_type_a_fract_bldg_area <= 0.0 + runner.registerError('Primary Building Type fraction of floor area must be greater than 0. Please lower one or more of the fractions for Building Type B-D.') + return false + end + + # Make the standard applier + standard = Standard.build((args['template']).to_s) + + # report initial condition of model + runner.registerInitialCondition("The building started with #{model.getSpaces.size} spaces.") + + # determine of ns_ew needs to be mirrored + mirror_ns_ew = false + rotation = model.getBuilding.northAxis + if rotation > 45.0 && rotation < 135.0 + mirror_ns_ew = true + elsif rotation > 45.0 && rotation < 135.0 + mirror_ns_ew = true + end + + # remove non-resource objects not removed by removing the building + remove_non_resource_objects(runner, model) + + # rename building to infer template in downstream measure + name_array = [args['template'], args['bldg_type_a']] + if args['bldg_type_b_fract_bldg_area'] > 0 then name_array << args['bldg_type_b'] end + if args['bldg_type_c_fract_bldg_area'] > 0 then name_array << args['bldg_type_c'] end + if args['bldg_type_d_fract_bldg_area'] > 0 then name_array << args['bldg_type_d'] end + model.getBuilding.setName(name_array.join('|').to_s) + + # hash to whole building type data + building_type_hash = {} + + # gather data for bldg_type_a + building_type_hash[args['bldg_type_a']] = {} + building_type_hash[args['bldg_type_a']][:frac_bldg_area] = bldg_type_a_fract_bldg_area + # building_type_hash[args['bldg_type_a']][:num_units] = args['bldg_type_a_num_units'] + building_type_hash[args['bldg_type_a']][:space_types] = get_space_types_from_building_type(args['bldg_type_a'], args['template'], true) + + # gather data for bldg_type_b + if args['bldg_type_b_fract_bldg_area'] > 0 + building_type_hash[args['bldg_type_b']] = {} + building_type_hash[args['bldg_type_b']][:frac_bldg_area] = args['bldg_type_b_fract_bldg_area'] + # building_type_hash[args['bldg_type_b']][:num_units] = args['bldg_type_b_num_units'] + building_type_hash[args['bldg_type_b']][:space_types] = get_space_types_from_building_type(args['bldg_type_b'], args['template'], true) + end + + # gather data for bldg_type_c + if args['bldg_type_c_fract_bldg_area'] > 0 + building_type_hash[args['bldg_type_c']] = {} + building_type_hash[args['bldg_type_c']][:frac_bldg_area] = args['bldg_type_c_fract_bldg_area'] + # building_type_hash[args['bldg_type_c']][:num_units] = args['bldg_type_c_num_units'] + building_type_hash[args['bldg_type_c']][:space_types] = get_space_types_from_building_type(args['bldg_type_c'], args['template'], true) + end + + # gather data for bldg_type_d + if args['bldg_type_d_fract_bldg_area'] > 0 + building_type_hash[args['bldg_type_d']] = {} + building_type_hash[args['bldg_type_d']][:frac_bldg_area] = args['bldg_type_d_fract_bldg_area'] + # building_type_hash[args['bldg_type_d']][:num_units] = args['bldg_type_d_num_units'] + building_type_hash[args['bldg_type_d']][:space_types] = get_space_types_from_building_type(args['bldg_type_d'], args['template'], true) + end + + # call bar_from_building_space_type_ratios to generate bar + bar_from_space_type_ratios(model, runner, user_arguments, args, building_type_hash) + + return true + + end + + # bar_from_space_type_ratios + # used for varieties of measures that create bar from space type or building type ratios + # args and building_type_hash should both be nil or neither shoould be nill + def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, building_type_hash = nil) + + # do not setup arguments if they were already passed in to this method + if args.nil? + # prep arguments + args = bar_arg_check_setup(model,runner,user_arguments,false) # false stops it from checking args on used in bar_from_building_type_ratios + if !args then return false end + + # process arg into hash + space_type_hash_name = {} + args['space_type_hash_string'][0..-1].split(/, /).each { |entry| entryMap = entry.split(/=>/); value_str = entryMap[1]; space_type_hash_name[entryMap[0].strip[0..-1].to_s] = value_str.nil? ? '' : value_str.strip[0..-1].to_f } + + # create building type hasn from space type ratios + building_type_hash = {} + building_type_fraction_of_building = 0.0 + space_type_hash_name.each do |building_space_type,ratio| + building_type = building_space_type.split("|")[0].strip + space_type = building_space_type.split("|")[1].strip + + # harvest height and circ info from get_space_types_from_building_type(building_type, template, whole_building = true) + building_type_lookup_info = get_space_types_from_building_type(building_type,args['template']) + if building_type_lookup_info.size == 0 + runner.registerWarning("#{building_type} looks like an invalid building type for #{args['template']}") + end + space_type_info_hash = {} + if building_type_lookup_info.key?(space_type) + if building_type_lookup_info[space_type].key?(:story_height) + space_type_info_hash[:story_height] = building_type_lookup_info[space_type][:story_height] + end + if building_type_lookup_info[space_type].key?(:default) + space_type_info_hash[:default] = building_type_lookup_info[space_type][:default] + end + if building_type_lookup_info[space_type].key?(:circ) + space_type_info_hash[:circ] = building_type_lookup_info[space_type][:circ] + end + else + runner.registerWarning("#{space_type} looks like an invalid space type for #{building_type}") + end + + # extend harvested data with custom ratios from space type ratio string argument. + if building_type_hash.key?(building_type) + building_type_hash[building_type][:frac_bldg_area] += ratio + space_type_info_hash[:ratio] = ratio + building_type_hash[building_type][:space_types][space_type] = space_type_info_hash + else + building_type_hash[building_type] = {} + building_type_hash[building_type][:frac_bldg_area] = ratio + space_type_info_hash[:ratio] = ratio + space_types = {} + space_types[space_type] = space_type_info_hash + building_type_hash[building_type][:space_types] = space_types + end + building_type_fraction_of_building += ratio + end + + # identify primary building type for building form defaults + primary_building_type = building_type_hash.keys.first # update to choose building with highest ratio + runner.registerInfo("Creating bar with space type ratio proided as argument.") + runner.registerInfo("Using building type from first ratio #{primary_building_type} as the primary building type. This is used for building form defaults.") + + # todo - confirm if this will get normalized up/down later of if I should fix or stop here instead of just a warning + if building_type_fraction_of_building > 1.0 + runner.registerWarning("Sum of Space Type Ratio of #{building_type_fraction_of_building} is greater than the expected value of 1.0") + elsif building_type_fraction_of_building < 1.0 + runner.registerWarning("Sum of Space Type Ratio of #{building_type_fraction_of_building} is less than the expected value of 1.0") + end + + else # else is used when bar_from_building_type_ratio is used + + # if aspect ratio, story height or wwr have argument value of 0 then use smart building type defaults + primary_building_type = args['bldg_type_a'] + runner.registerInfo("Creating bar space type ratios by building type based on ratios from prototype models.") + runner.registerInfo("#{primary_building_type} will be used for building form defaults.") + + end + + # get defaults for the primary building type + building_form_defaults = building_form_defaults(primary_building_type) + + # store list of defaulted items + defaulted_args = [] + + if args['ns_to_ew_ratio'] == 0.0 + args['ns_to_ew_ratio'] = building_form_defaults[:aspect_ratio] + runner.registerInfo("0.0 value for aspect ratio will be replaced with smart default for #{primary_building_type} of #{building_form_defaults[:aspect_ratio]}.") + end + + if args['perim_mult'] == 0.0 + # if this is not defined then use default of 1.0 + if !building_form_defaults.has_key?(:perim_mult) + args['perim_mult'] = 1.0 + else + args['perim_mult'] = building_form_defaults[:perim_mult] + end + runner.registerInfo("0.0 value for minimum perimeter multiplier will be replaced with smart default for #{primary_building_type} of #{building_form_defaults[:perim_mult]}.") + elsif args['perim_mult'] < 1.0 + runner.registerError("Other than the smart default value of 0, the minimum perimeter multiplier should be equal to 1.0 or greater.") + return false + end + + if args['floor_height'] == 0.0 + args['floor_height'] = building_form_defaults[:typical_story] + runner.registerInfo("0.0 value for floor height will be replaced with smart default for #{primary_building_type} of #{building_form_defaults[:typical_story]}.") + defaulted_args << 'floor_height' + end + # because of this can't set wwr to 0.0. If that is desired then we can change this to check for 1.0 instead of 0.0 + if args['wwr'] == 0.0 + args['wwr'] = building_form_defaults[:wwr] + runner.registerInfo("0.0 value for window to wall ratio will be replaced with smart default for #{primary_building_type} of #{building_form_defaults[:wwr]}.") + end + + # Make the standard applier + standard = Standard.build("#{args['template']}") + + # report initial condition of model + runner.registerInitialCondition("The building started with #{model.getSpaces.size} spaces.") + + # determine of ns_ew needs to be mirrored + mirror_ns_ew = false + rotation = model.getBuilding.northAxis + if rotation > 45.0 && rotation < 135.0 + mirror_ns_ew = true + elsif rotation > 45.0 && rotation < 135.0 + mirror_ns_ew = true + end + + # remove non-resource objects not removed by removing the building + remove_non_resource_objects(runner, model) + + # creating space types for requested building types + building_type_hash.each do |building_type, building_type_hash| + runner.registerInfo("Creating Space Types for #{building_type}.") + + # mapping building_type name is needed for a few methods + building_type = standard.model_get_lookup_name(building_type) + + # create space_type_map from array + sum_of_ratios = 0.0 + building_type_hash[:space_types] = building_type_hash[:space_types].sort_by { |k, v| v[:ratio] }.to_h + building_type_hash[:space_types].each do |space_type_name, hash| + next if hash[:space_type_gen] == false # space types like undeveloped and basement are skipped. + + # create space type + space_type = OpenStudio::Model::SpaceType.new(model) + space_type.setStandardsBuildingType(building_type) + space_type.setStandardsSpaceType(space_type_name) + space_type.setName("#{building_type} #{space_type_name}") + + # set color + test = standard.space_type_apply_rendering_color(space_type) # this uses openstudio-standards + if !test + # TODO: - once fixed in standards un-comment this + # runner.registerWarning("Could not find color for #{args['template']} #{space_type.name}") + end + + # extend hash to hold new space type object + hash[:space_type] = space_type + + # add to sum_of_ratios counter for adjustment multiplier + sum_of_ratios += hash[:ratio] + end + + # store multiplier needed to adjust sum of ratios to equal 1.0 + building_type_hash[:ratio_adjustment_multiplier] = 1.0 / sum_of_ratios + end + + # calculate length and with of bar + total_bldg_floor_area_si = OpenStudio.convert(args['total_bldg_floor_area'], 'ft^2', 'm^2').get + single_floor_area_si = OpenStudio.convert(args['single_floor_area'], 'ft^2', 'm^2').get + + # store number of stories + num_stories = args['num_stories_below_grade'] + args['num_stories_above_grade'] + + # handle user-assigned single floor plate size condition + if args['single_floor_area'] > 0.0 + footprint_si = single_floor_area_si + total_bldg_floor_area_si = footprint_si * num_stories.to_f + runner.registerWarning('User-defined single floor area was used for calculation of total building floor area') + # add warning if custom_height_bar is true and applicable building type is selected + if args['custom_height_bar'] + runner.registerWarning('Cannot use custom height bar with single floor area method, will not create custom height bar.') + args['custom_height_bar'] = false + end + else + footprint_si = nil + end + + # populate space_types_hash + space_types_hash = {} + multi_height_space_types_hash = {} + custom_story_heights = [] + if args['space_type_sort_logic'] == 'Building Type > Size' + building_type_hash = building_type_hash.sort_by { |k, v| v[:frac_bldg_area] } + end + building_type_hash.each do |building_type, building_type_hash| + if args['double_loaded_corridor'] == 'Primary Space Type' + + # see if building type has circulation space type, if so then merge that along with default space type into hash key in place of space type + default_st = nil + circ_st = nil + building_type_hash[:space_types].each do |space_type_name, hash| + if hash[:default] then default_st = space_type_name end + if hash[:circ] then circ_st = space_type_name end + end + + # update building hash + if !default_st.nil? && !circ_st.nil? + runner.registerInfo("Combining #{default_st} and #{circ_st} into a group representing a double loaded corridor") + + # add new item + building_type_hash[:space_types]['Double Loaded Corridor'] = {} + double_loaded_st = building_type_hash[:space_types]['Double Loaded Corridor'] + double_loaded_st[:ratio] = building_type_hash[:space_types][default_st][:ratio] + building_type_hash[:space_types][circ_st][:ratio] + double_loaded_st[:double_loaded_corridor] = true + double_loaded_st[:space_type] = model.getBuilding + double_loaded_st[:children] = {} + building_type_hash[:space_types][default_st][:orig_ratio] = building_type_hash[:ratio_adjustment_multiplier] * building_type_hash[:frac_bldg_area] * building_type_hash[:space_types][default_st][:ratio] + building_type_hash[:space_types][circ_st][:orig_ratio] = building_type_hash[:ratio_adjustment_multiplier] * building_type_hash[:frac_bldg_area] * building_type_hash[:space_types][circ_st][:ratio] + building_type_hash[:space_types][default_st][:name] = default_st + building_type_hash[:space_types][circ_st][:name] = circ_st + double_loaded_st[:children][:default] = building_type_hash[:space_types][default_st] + double_loaded_st[:children][:circ] = building_type_hash[:space_types][circ_st] + double_loaded_st[:orig_ratio] = 0.0 + + # zero out ratios from old item (don't delete because I still want the space types made) + building_type_hash[:space_types][default_st][:ratio] = 0.0 + building_type_hash[:space_types][circ_st][:ratio] = 0.0 + end + end + + building_type_hash[:space_types].each do |space_type_name, hash| + next if hash[:space_type_gen] == false + + space_type = hash[:space_type] + ratio_of_bldg_total = hash[:ratio] * building_type_hash[:ratio_adjustment_multiplier] * building_type_hash[:frac_bldg_area] + final_floor_area = ratio_of_bldg_total * total_bldg_floor_area_si # I think I can just pass ratio but passing in area is cleaner + + # only add custom height space if 0 is used for floor_height + if defaulted_args.include?('floor_height') && hash.key?(:story_height) && args['custom_height_bar'] + multi_height_space_types_hash[space_type] = { floor_area: final_floor_area, space_type: space_type, story_height: hash[:story_height] } + if hash.key?(:orig_ratio) then multi_height_space_types_hash[space_type][:orig_ratio] = hash[:orig_ratio] end + custom_story_heights << hash[:story_height] + if args['wwr'] == 0 && hash.key?(:wwr) + multi_height_space_types_hash[space_type][:wwr] = hash[:wwr] + end + else + # only add wwr if 0 used for wwr arg and if space type has wwr as key + space_types_hash[space_type] = { floor_area: final_floor_area, space_type: space_type } + if hash.key?(:orig_ratio) then space_types_hash[space_type][:orig_ratio] = hash[:orig_ratio] end + if args['wwr'] == 0 && hash.key?(:wwr) + space_types_hash[space_type][:wwr] = hash[:wwr] + end + if hash[:double_loaded_corridor] + space_types_hash[space_type][:children] = hash[:children] + end + end + end + end + + # resort if not sorted by building type + if args['space_type_sort_logic'] == 'Size' + # added code to convert to hash. I use sort_by 3 other times, but those seem to be working fine as is now. + space_types_hash = Hash[space_types_hash.sort_by { |k, v| v[:floor_area] }] + end + + # calculate targets for testing + target_areas = {} # used for checks + target_areas_cust_height = 0.0 + space_types_hash.each do |k, v| + if v.key?(:orig_ratio) + target_areas[k] = v[:orig_ratio] * total_bldg_floor_area_si + else + target_areas[k] = v[:floor_area] + end + end + multi_height_space_types_hash.each do |k, v| + if v.key?(:orig_ratio) + target_areas[k] = v[:orig_ratio] * total_bldg_floor_area_si + target_areas_cust_height += v[:orig_ratio] * total_bldg_floor_area_si + else + target_areas[k] = v[:floor_area] + target_areas_cust_height += v[:floor_area] + end + end + + # gather inputs + if footprint_si.nil? + footprint_si = (total_bldg_floor_area_si - target_areas_cust_height) / num_stories.to_f + end + floor_height_si = OpenStudio.convert(args['floor_height'], 'ft', 'm').get + min_allow_size = OpenStudio.convert(15.0, 'ft', 'm').get + specified_bar_width_si = OpenStudio.convert(args['bar_width'], 'ft', 'm').get + + # set custom width + if specified_bar_width_si > 0 + runner.registerInfo('Ignoring perimeter multiplier argument when non zero width argument is used') + if footprint_si / specified_bar_width_si >= min_allow_size + width = specified_bar_width_si + length = footprint_si / width + else + length = min_allow_size + width = footprint_si / length + runner.registerWarning('User specified width results in a length that is too short, adjusting width to be narrower than specified.') + end + width_cust_height = specified_bar_width_si + else + width = Math.sqrt(footprint_si / args['ns_to_ew_ratio']) + length = footprint_si / width + width_cust_height = Math.sqrt(target_areas_cust_height / args['ns_to_ew_ratio']) + end + length_cust_height = target_areas_cust_height / width_cust_height + if args['perim_mult'] > 1.0 && target_areas_cust_height > 0.0 + # TODO: - update tests that hit this warning + runner.registerWarning('Ignoring perimeter multiplier for bar that represents custom height spaces.') + end + + # check if dual bar is needed + dual_bar = false + if specified_bar_width_si > 0.0 && args['bar_division_method'] == 'Multiple Space Types - Individual Stories Sliced' + if length / width != args['ns_to_ew_ratio'] + + if args['ns_to_ew_ratio'] >= 1.0 && args['ns_to_ew_ratio'] > length / width + runner.registerWarning("Can't meet target aspect ratio of #{args['ns_to_ew_ratio']}, Lowering it to #{length / width} ") + args['ns_to_ew_ratio'] = length / width + elsif args['ns_to_ew_ratio'] < 1.0 && args['ns_to_ew_ratio'] > length / width + runner.registerWarning("Can't meet target aspect ratio of #{args['ns_to_ew_ratio']}, Increasing it to #{length / width} ") + args['ns_to_ew_ratio'] = length / width + else + # check if each bar would be longer then 15 feet, then set as dual bar and override perimeter multiplier + length_alt1 = ((args['ns_to_ew_ratio'] * footprint_si) / width + 2 * args['ns_to_ew_ratio'] * width - 2 * width) / (1 + args['ns_to_ew_ratio']) + length_alt2 = length - length_alt1 + if [length_alt1, length_alt2].min >= min_allow_size + dual_bar = true + else + runner.registerInfo('Second bar would be below minimum length, will model as single bar') + # swap length and width if single bar and aspect ratio less than 1 + if args['ns_to_ew_ratio'] < 1.0 + width = length + length = specified_bar_width_si + end + end + end + end + elsif args['perim_mult'] > 1.0 && args['bar_division_method'] == 'Multiple Space Types - Individual Stories Sliced' + runner.registerInfo('You selected a perimeter multiplier greater than 1.0 for a supported bar division method. This will result in two detached rectangular buildings if secondary bar meets minimum size requirements.') + dual_bar = true + elsif args['perim_mult'] > 1.0 + runner.registerWarning("You selected a perimeter multiplier greater than 1.0 but didn't select a bar division method that supports this. The value for this argument will be ignored by the measure") + end + + # calculations for dual bar, which later will be setup to run create_bar twice + if dual_bar + min_perim = 2 * width + 2 * length + target_area = footprint_si + target_perim = min_perim * args['perim_mult'] + tol_testing = 0.00001 + dual_bar_calc_approach = nil # stretched, adiabatic_ends_bar_b, dual_bar + runner.registerInfo("Minimum rectangle is #{OpenStudio.toNeatString(OpenStudio.convert(length, 'm', 'ft').get, 0, true)} ft x #{OpenStudio.toNeatString(OpenStudio.convert(width, 'm', 'ft').get, 0, true)} ft with an area of #{OpenStudio.toNeatString(OpenStudio.convert(length * width, 'm^2', 'ft^2').get, 0, true)} ft^2. Perimeter is #{OpenStudio.toNeatString(OpenStudio.convert(min_perim, 'm', 'ft').get, 0, true)} ft.") + runner.registerInfo("Target dual bar perimeter is #{OpenStudio.toNeatString(OpenStudio.convert(target_perim, 'm', 'ft').get, 0, true)} ft.") + + # determine which of the three paths to hit target perimeter multiplier are possible + # A use dual bar non adiabatic + # B use dual bar adiabatic + # C use stretched bar (requires model to miss ns/ew ratio) + + # custom quadratic equation to solve two bars with common width 2l^2 - p*l + 4a = 0 + if target_perim**2 - 32 * footprint_si > 0 + if specified_bar_width_si > 0 + runner.registerInfo('Ignoring perimeter multiplier argument and using use specified bar width.') + dual_double_end_width = specified_bar_width_si + dual_double_end_length = footprint_si / dual_double_end_width + else + dual_double_end_length = 0.25 * (target_perim + Math.sqrt(target_perim**2 - 32 * footprint_si)) + dual_double_end_width = footprint_si / dual_double_end_length + end + + # now that stretched bar is made, determine where to split it and rotate + bar_a_length = (args['ns_to_ew_ratio'] * (dual_double_end_length + dual_double_end_width) - dual_double_end_width) / (1 + args['ns_to_ew_ratio']) + bar_b_length = dual_double_end_length - bar_a_length + area_a = bar_a_length * dual_double_end_width + area_b = bar_b_length * dual_double_end_width + else + # this will throw it to adiabatic ends test + bar_a_length = 0 + bar_b_length = 0 + end + + if bar_a_length >= min_allow_size && bar_b_length >= min_allow_size + dual_bar_calc_approach = 'dual_bar' + else + # adiabatic bar input calcs + if target_perim**2 - 16 * footprint_si > 0 + adiabatic_dual_double_end_length = 0.25 * (target_perim + Math.sqrt(target_perim**2 - 16 * footprint_si)) + adiabatic_dual_double_end_width = footprint_si / adiabatic_dual_double_end_length + # test for unexpected + unexpected = false + if (target_area - adiabatic_dual_double_end_length * adiabatic_dual_double_end_width).abs > tol_testing then unexpected = true end + if specified_bar_width_si == 0 + if (target_perim - (adiabatic_dual_double_end_length * 2 + adiabatic_dual_double_end_width * 2)).abs > tol_testing then unexpected = true end + end + if unexpected + runner.registerWarning('Unexpected values for dual rectangle adiabatic ends bar b.') + end + # now that stretched bar is made, determine where to split it and rotate + adiabatic_bar_a_length = (args['ns_to_ew_ratio'] * (adiabatic_dual_double_end_length + adiabatic_dual_double_end_width)) / (1 + args['ns_to_ew_ratio']) + adiabatic_bar_b_length = adiabatic_dual_double_end_length - adiabatic_bar_a_length + adiabatic_area_a = adiabatic_bar_a_length * adiabatic_dual_double_end_width + adiabatic_area_b = adiabatic_bar_b_length * adiabatic_dual_double_end_width + else + # this will throw it stretched single bar + adiabatic_bar_a_length = 0 + adiabatic_bar_b_length = 0 + end + if adiabatic_bar_a_length >= min_allow_size && adiabatic_bar_b_length >= min_allow_size + dual_bar_calc_approach = 'adiabatic_ends_bar_b' + else + dual_bar_calc_approach = 'stretched' + end + end + + # apply prescribed approach for stretched or dual bar + if dual_bar_calc_approach == 'dual_bar' + runner.registerInfo("Stretched #{OpenStudio.toNeatString(OpenStudio.convert(dual_double_end_length, 'm', 'ft').get, 0, true)} ft x #{OpenStudio.toNeatString(OpenStudio.convert(dual_double_end_width, 'm', 'ft').get, 0, true)} ft rectangle has an area of #{OpenStudio.toNeatString(OpenStudio.convert(dual_double_end_length * dual_double_end_width, 'm^2', 'ft^2').get, 0, true)} ft^2. When split in two the perimeter will be #{OpenStudio.toNeatString(OpenStudio.convert(dual_double_end_length * 2 + dual_double_end_width * 4, 'm', 'ft').get, 0, true)} ft") + if (target_area - dual_double_end_length * dual_double_end_width).abs > tol_testing || (target_perim - (dual_double_end_length * 2 + dual_double_end_width * 4)).abs > tol_testing + runner.registerWarning('Unexpected values for dual rectangle.') + end + + runner.registerInfo("For stretched split bar, to match target ns/ew aspect ratio #{OpenStudio.toNeatString(OpenStudio.convert(bar_a_length, 'm', 'ft').get, 0, true)} ft of bar should be horizontal, with #{OpenStudio.toNeatString(OpenStudio.convert(bar_b_length, 'm', 'ft').get, 0, true)} ft turned 90 degrees. Combined area is #{OpenStudio.toNeatString(OpenStudio.convert(area_a + area_b, 'm^2', 'ft^2').get, 0, true)} ft^2. Combined perimeter is #{OpenStudio.toNeatString(OpenStudio.convert(bar_a_length * 2 + bar_b_length * 2 + dual_double_end_width * 4, 'm', 'ft').get, 0, true)} ft") + if (target_area - (area_a + area_b)).abs > tol_testing || (target_perim - (bar_a_length * 2 + bar_b_length * 2 + dual_double_end_width * 4)).abs > tol_testing + runner.registerWarning('Unexpected values for rotated dual rectangle') + end + elsif dual_bar_calc_approach == 'adiabatic_ends_bar_b' + runner.registerInfo("Can't hit target perimeter with two rectangles, need to make two ends adiabatic") + + runner.registerInfo("For dual bar with adiabatic ends on bar b, to reach target aspect ratio #{OpenStudio.toNeatString(OpenStudio.convert(adiabatic_bar_a_length, 'm', 'ft').get, 0, true)} ft of bar should be north/south, with #{OpenStudio.toNeatString(OpenStudio.convert(adiabatic_bar_b_length, 'm', 'ft').get, 0, true)} ft turned 90 degrees. Combined area is #{OpenStudio.toNeatString(OpenStudio.convert(adiabatic_area_a + adiabatic_area_b, 'm^2', 'ft^2').get, 0, true)} ft^2}. Combined perimeter is #{OpenStudio.toNeatString(OpenStudio.convert(adiabatic_bar_a_length * 2 + adiabatic_bar_b_length * 2 + adiabatic_dual_double_end_width * 2, 'm', 'ft').get, 0, true)} ft") + if (target_area - (adiabatic_area_a + adiabatic_area_b)).abs > tol_testing || (target_perim - (adiabatic_bar_a_length * 2 + adiabatic_bar_b_length * 2 + adiabatic_dual_double_end_width * 2)).abs > tol_testing + runner.registerWarning('Unexpected values for rotated dual rectangle adiabatic ends bar b') + end + else # stretched bar + dual_bar = false + + stretched_length = 0.25 * (target_perim + Math.sqrt(target_perim**2 - 16 * footprint_si)) + stretched_width = footprint_si / stretched_length + if (target_area - stretched_length * stretched_width).abs > tol_testing || (target_perim - (stretched_length + stretched_width) * 2) > tol_testing + runner.registerWarning('Unexpected values for single stretched') + end + + width = stretched_width + length = stretched_length + runner.registerInfo("Creating a dual bar to match the target minimum perimeter multiplier at the given aspect ratio would result in a bar with edge shorter than #{OpenStudio.toNeatString(OpenStudio.convert(min_allow_size, 'm', 'ft').get, 0, true)} ft. Will create a single stretched bar instead that hits the target perimeter with a slightly different ns/ew aspect ratio.") + end + end + + bars = {} + bars['primary'] = {} + if dual_bar + if mirror_ns_ew && dual_bar_calc_approach == 'dual_bar' + bars['primary'][:length] = dual_double_end_width + bars['primary'][:width] = bar_a_length + elsif dual_bar_calc_approach == 'dual_bar' + bars['primary'][:length] = bar_a_length + bars['primary'][:width] = dual_double_end_width + elsif mirror_ns_ew + bars['primary'][:length] = adiabatic_dual_double_end_width + bars['primary'][:width] = adiabatic_bar_a_length + else + bars['primary'][:length] = adiabatic_bar_a_length + bars['primary'][:width] = adiabatic_dual_double_end_width + end + else + if mirror_ns_ew + bars['primary'][:length] = width + bars['primary'][:width] = length + else + bars['primary'][:length] = length + bars['primary'][:width] = width + end + end + bars['primary'][:floor_height_si] = floor_height_si # can make use of this when breaking out multi-height spaces + bars['primary'][:num_stories] = num_stories + bars['primary'][:center_of_footprint] = OpenStudio::Point3d.new(0.0, 0.0, 0.0) + space_types_hash_secondary = {} + if dual_bar + # loop through each story and move portion for other bar to its own hash + primary_footprint = bars['primary'][:length] * bars['primary'][:width] + secondary_footprint = target_area - primary_footprint + footprint_counter = primary_footprint + secondary_footprint_counter = secondary_footprint + story_counter = 0 + pri_sec_tol = 0.0001 # m^2 + pri_sec_min_area = 0.0001 # m^2 + space_types_hash.each do |k, v| + space_type_left = v[:floor_area] + + # do not go to next space type until this one is evaulate, which may span stories + until space_type_left == 0.0 || story_counter >= num_stories + + # use secondary footprint if any left + if secondary_footprint_counter > 0.0 + hash_area = [space_type_left, secondary_footprint_counter].min + + # confirm that the part of space type use or what is left is greater than min allowed value + projected_space_type_left = space_type_left - hash_area + test_a = hash_area >= pri_sec_min_area + test_b = projected_space_type_left >= pri_sec_min_area || projected_space_type_left == 0.0 ? true : false + test_c = k == space_types_hash.keys.last # if last space type accept sliver, no other space to infil + if (test_a && test_b) || test_c + if space_types_hash_secondary.key?(k) + # add to what was added for previous story + space_types_hash_secondary[k][:floor_area] += hash_area + else + # add new space type to hash + if v.key?(:children) + space_types_hash_secondary[k] = { floor_area: hash_area, space_type: v[:space_type], children: v[:children] } + else + space_types_hash_secondary[k] = { floor_area: hash_area, space_type: v[:space_type] } + end + end + space_types_hash[k][:floor_area] -= hash_area + secondary_footprint_counter -= hash_area + space_type_left -= hash_area + else + runner.registerInfo("Shifting space types between bars to avoid sliver of #{k.name}.") + end + end + + # remove space if entirely used up by secondary bar + if space_types_hash[k][:floor_area] <= pri_sec_tol + space_types_hash.delete(k) + space_type_left = 0.0 + else + # then look at primary bar + hash_area_pri = [space_type_left, footprint_counter].min + footprint_counter -= hash_area_pri + space_type_left -= hash_area_pri + end + + # reset counter when full + if footprint_counter <= pri_sec_tol && secondary_footprint_counter <= pri_sec_tol + # check if this is partial top floor + story_counter += 1 + if num_stories < story_counter + 1 + footprint_counter = primary_footprint * (num_stories - story_counter) + secondary_footprint_counter = secondary_footprint * (num_stories - story_counter) + else + footprint_counter = primary_footprint + secondary_footprint_counter = secondary_footprint + end + end + end + end + end + + # setup bar_hash and run create_bar + bars['primary'][:space_types_hash] = space_types_hash + bars['primary'][:args] = args + v = bars['primary'] + bar_hash_setup_run(runner, model, v[:args], v[:length], v[:width], v[:floor_height_si], v[:center_of_footprint], v[:space_types_hash], v[:num_stories]) + + # store offset value for multiple bars + if args.key?('bar_sep_dist_mult') && args['bar_sep_dist_mult'] > 0.0 + offset_val = num_stories.ceil * floor_height_si * args['bar_sep_dist_mult'] + elsif args.key?('bar_sep_dist_mult') + runner.registerWarning('Positive value is required for bar_sep_dist_mult, ignoring input and using value of 0.1') + offset_val = num_stories.ceil * floor_height_si * 0.1 + else + offset_val = num_stories.ceil * floor_height_si * 10.0 + end + + if dual_bar + args2 = args.clone + bars['secondary'] = {} + if mirror_ns_ew && dual_bar_calc_approach == 'dual_bar' + bars['secondary'][:length] = bar_b_length + bars['secondary'][:width] = dual_double_end_width + elsif dual_bar_calc_approach == 'dual_bar' + bars['secondary'][:length] = dual_double_end_width + bars['secondary'][:width] = bar_b_length + elsif mirror_ns_ew + bars['secondary'][:length] = adiabatic_bar_b_length + bars['secondary'][:width] = adiabatic_dual_double_end_width + args2['party_wall_stories_east'] = num_stories.ceil + args2['party_wall_stories_west'] = num_stories.ceil + else + bars['secondary'][:length] = adiabatic_dual_double_end_width + bars['secondary'][:width] = adiabatic_bar_b_length + args2['party_wall_stories_south'] = num_stories.ceil + args2['party_wall_stories_north'] = num_stories.ceil + end + bars['secondary'][:floor_height_si] = floor_height_si # can make use of this when breaking out multi-height spaces + bars['secondary'][:num_stories] = num_stories + bars['secondary'][:space_types_hash] = space_types_hash_secondary + if dual_bar_calc_approach == 'adiabatic_ends_bar_b' + # warn that combination of dual bar with low perimeter multiplier and use of party wall may result in discrepency between target and actual adiabatic walls + if args['party_wall_fraction'] > 0 || args['party_wall_stories_north'] > 0 || args['party_wall_stories_south'] > 0 || args['party_wall_stories_east'] > 0 || args['party_wall_stories_west'] > 0 + runner.registerWarning('The combination of low perimeter multiplier and use of non zero party wall inputs may result in discrepency between target and actual adiabatic walls. This is due to the need to create adiabatic walls on secondary bar to maintian target building perimeter.') + else + runner.registerInfo('Adiabatic ends added to secondary bar because target perimeter multiplier could not be met with two full rectangular footprints.') + end + bars['secondary'][:center_of_footprint] = OpenStudio::Point3d.new(adiabatic_bar_a_length * 0.5 + adiabatic_dual_double_end_width * 0.5 + offset_val, adiabatic_bar_b_length * 0.5 + adiabatic_dual_double_end_width * 0.5 + offset_val, 0.0) + else + bars['secondary'][:center_of_footprint] = OpenStudio::Point3d.new(bar_a_length * 0.5 + dual_double_end_width * 0.5 + offset_val, bar_b_length * 0.5 + dual_double_end_width * 0.5 + offset_val, 0.0) + end + bars['secondary'][:args] = args2 + + # setup bar_hash and run create_bar + v = bars['secondary'] + bar_hash_setup_run(runner, model, v[:args], v[:length], v[:width], v[:floor_height_si], v[:center_of_footprint], v[:space_types_hash], v[:num_stories]) + + end + + # future development (up against primary bar run intersection and surface matching after add all bars, avoid interior windows) + # I could loop through each space type and give them unique height but for now will just take largest height and make bar of that height, which is fine for prototypes + if !multi_height_space_types_hash.empty? + args3 = args.clone + bars['custom_height'] = {} + if mirror_ns_ew + bars['custom_height'][:length] = width_cust_height + bars['custom_height'][:width] = length_cust_height + else + bars['custom_height'][:length] = length_cust_height + bars['custom_height'][:width] = width_cust_height + end + if args['party_wall_stories_east'] + args['party_wall_stories_west'] + args['party_wall_stories_south'] + args['party_wall_stories_north'] > 0.0 + runner.registerWarning('Ignorning party wall inputs for custom height bar') + end + + # disable party walls + args3['party_wall_stories_east'] = 0 + args3['party_wall_stories_west'] = 0 + args3['party_wall_stories_south'] = 0 + args3['party_wall_stories_north'] = 0 + + # setup stories + args3['num_stories_below_grade'] = 0 + args3['num_stories_above_grade'] = 1 + + bars['custom_height'][:floor_height_si] = floor_height_si # can make use of this when breaking out multi-height spaces + bars['custom_height'][:num_stories] = num_stories + bars['custom_height'][:center_of_footprint] = OpenStudio::Point3d.new(bars['primary'][:length] * -0.5 - length_cust_height * 0.5 - offset_val, 0.0, 0.0) + bars['custom_height'][:floor_height_si] = OpenStudio.convert(custom_story_heights.max, 'ft', 'm').get + bars['custom_height'][:num_stories] = 1 + bars['custom_height'][:space_types_hash] = multi_height_space_types_hash + bars['custom_height'][:args] = args3 + + v = bars['custom_height'] + bar_hash_setup_run(runner, model, v[:args], v[:length], v[:width], v[:floor_height_si], v[:center_of_footprint], v[:space_types_hash], v[:num_stories]) + end + + # diagnostic log + sum_actual = 0.0 + sum_target = 0.0 + throw_error = false + + # check expected floor areas against actual + model.getSpaceTypes.sort.each do |space_type| + next if !target_areas.key? space_type # space type in model not part of building type(s), maybe issue warning + + # convert to IP + actual_ip = OpenStudio.convert(space_type.floorArea, 'm^2', 'ft^2').get + target_ip = OpenStudio.convert(target_areas[space_type], 'm^2', 'ft^2').get + sum_actual += actual_ip + sum_target += target_ip + + if (space_type.floorArea - target_areas[space_type]).abs >= 1.0 + + if !args['bar_division_method'].include? 'Single Space Type' + runner.registerError("#{space_type.name} doesn't have the expected floor area (actual #{OpenStudio.toNeatString(actual_ip, 0, true)} ft^2, target #{OpenStudio.toNeatString(target_ip, 0, true)} ft^2)") + throw_error = true + else + # will see this if use Single Space type division method on multi-use building or single building type without whole building space type + runner.registerWarning("#{space_type.name} doesn't have the expected floor area (actual #{OpenStudio.toNeatString(actual_ip, 0, true)} ft^2, target #{OpenStudio.toNeatString(target_ip, 0, true)} ft^2)") + end + + end + end + + # report summary then throw error + if throw_error + runner.registerError("Sum of actual floor area is #{sum_actual} ft^2, sum of target floor area is #{sum_target}.") + return false + end + + # check party wall fraction by looping through surfaces + if args['party_wall_fraction'] > 0 + actual_ext_wall_area = model.getBuilding.exteriorWallArea + actual_party_wall_area = 0.0 + model.getSurfaces.sort.each do |surface| + next if surface.outsideBoundaryCondition != 'Adiabatic' + next if surface.surfaceType != 'Wall' + actual_party_wall_area += surface.grossArea * surface.space.get.multiplier + end + actual_party_wall_fraction = actual_party_wall_area / (actual_party_wall_area + actual_ext_wall_area) + runner.registerInfo("Target party wall fraction is #{args['party_wall_fraction']}. Realized fraction is #{actual_party_wall_fraction.round(2)}") + runner.registerValue('party_wall_fraction_actual', actual_party_wall_fraction) + end + + # check ns/ew aspect ratio (harder to check when party walls are added) + wall_and_window_by_orientation = OsLib_Geometry.getExteriorWindowAndWllAreaByOrientation(model, model.getSpaces) + wall_ns = (wall_and_window_by_orientation['northWall'] + wall_and_window_by_orientation['southWall']) + wall_ew = wall_and_window_by_orientation['eastWall'] + wall_and_window_by_orientation['westWall'] + wall_ns_ip = OpenStudio.convert(wall_ns, 'm^2', 'ft^2').get + wall_ew_ip = OpenStudio.convert(wall_ew, 'm^2', 'ft^2').get + runner.registerValue('wall_area_ip', wall_ns_ip + wall_ew_ip, 'ft^2') + runner.registerValue('ns_wall_area_ip', wall_ns_ip, 'ft^2') + runner.registerValue('ew_wall_area_ip', wall_ew_ip, 'ft^2') + # for now using perimeter of ground floor and average story area (building area / num_stories) + runner.registerValue('floor_area_to_perim_ratio', model.getBuilding.floorArea / (OsLib_Geometry.calculate_perimeter(model) * num_stories)) + runner.registerValue('bar_width_output', OpenStudio.convert(bars['primary'][:width], 'm', 'ft').get, 'ft') + + if args['party_wall_fraction'] > 0 || args['party_wall_stories_north'] > 0 || args['party_wall_stories_south'] > 0 || args['party_wall_stories_east'] > 0 || args['party_wall_stories_west'] > 0 + runner.registerInfo('Target facade area by orientation not validated when party walls are applied') + elsif args['num_stories_above_grade'] != args['num_stories_above_grade'].ceil + runner.registerInfo('Target facade area by orientation not validated when partial top story is used') + elsif dual_bar_calc_approach == 'stretched' + runner.registerInfo('Target facade area by orientation not validated when single stretched bar has to be used to meet target minimum perimeter multiplier') + elsif defaulted_args.include?('floor_height') && args['custom_height_bar'] && !multi_height_space_types_hash.empty? + runner.registerInfo('Target facade area by orientation not validated when a dedicated bar is added for space types with custom heights') + elsif args['bar_width'] > 0 + runner.registerInfo('Target facade area by orientation not validated when a dedicated custom bar width is defined') + else + + # adjust length versus width based on building rotation + if mirror_ns_ew + wall_target_ns_ip = 2 * OpenStudio.convert(width, 'm', 'ft').get * args['perim_mult'] * args['num_stories_above_grade'] * args['floor_height'] + wall_target_ew_ip = 2 * OpenStudio.convert(length, 'm', 'ft').get * args['perim_mult'] * args['num_stories_above_grade'] * args['floor_height'] + else + wall_target_ns_ip = 2 * OpenStudio.convert(length, 'm', 'ft').get * args['perim_mult'] * args['num_stories_above_grade'] * args['floor_height'] + wall_target_ew_ip = 2 * OpenStudio.convert(width, 'm', 'ft').get * args['perim_mult'] * args['num_stories_above_grade'] * args['floor_height'] + end + flag_error = false + if (wall_target_ns_ip - wall_ns_ip).abs > 0.1 + runner.registerError("North/South walls don't have the expected area (actual #{OpenStudio.toNeatString(wall_ns_ip, 4, true)} ft^2, target #{OpenStudio.toNeatString(wall_target_ns_ip, 4, true)} ft^2)") + flag_error = true + end + if (wall_target_ew_ip - wall_ew_ip).abs > 0.1 + runner.registerError("East/West walls don't have the expected area (actual #{OpenStudio.toNeatString(wall_ew_ip, 4, true)} ft^2, target #{OpenStudio.toNeatString(wall_target_ew_ip, 4, true)} ft^2)") + flag_error = true + end + if flag_error + return false + end + end + + # test for excessive exterior roof area (indication of problem with intersection and or surface matching) + ext_roof_area = model.getBuilding.exteriorSurfaceArea - model.getBuilding.exteriorWallArea + expected_roof_area = args['total_bldg_floor_area'] / (args['num_stories_above_grade'] + args['num_stories_below_grade']).to_f + if ext_roof_area > expected_roof_area && single_floor_area_si == 0.0 # only test if using whole-building area input + runner.registerError('Roof area larger than expected, may indicate problem with inter-floor surface intersection or matching.') + return false + end + + # set building rotation + initial_rotation = model.getBuilding.northAxis + if args['building_rotation'] != initial_rotation + model.getBuilding.setNorthAxis(args['building_rotation']) + runner.registerInfo("Set Building Rotation to #{model.getBuilding.northAxis}. Rotation altered after geometry generation is completed, as a result party wall orientation and aspect ratio may not reflect input values.") + end + + # report final condition of model + runner.registerFinalCondition("The building finished with #{model.getSpaces.size} spaces.") + + return true + end + + end +end \ No newline at end of file diff --git a/lib/openstudio-standards/geometry/information.rb b/lib/openstudio-standards/geometry/information.rb new file mode 100644 index 0000000000..04d56bc864 --- /dev/null +++ b/lib/openstudio-standards/geometry/information.rb @@ -0,0 +1,19 @@ +# Methods to get information about model geometry +# Many of these methods may be moved to core OpenStudio +module OpenstudioStandards + module Geometry + # @!group Information + + # calculate aspect ratio from area and perimeter + # @param area [Double] area + # @param perimeter [Double] perimeter + # @return [Double] aspect ratio + def self.calc_aspect_ratio(area, perimeter) + l = 0.25 * (perimeter + Math.sqrt(p**2 - 16 * area)) + w = 0.25 * (perimeter - Math.sqrt(p**2 - 16 * area)) + aspect_ratio = l / w + + return aspect_ratio + end + end +end \ No newline at end of file diff --git a/lib/openstudio-standards/geometry/modify.rb b/lib/openstudio-standards/geometry/modify.rb new file mode 100644 index 0000000000..7cb8d4ba73 --- /dev/null +++ b/lib/openstudio-standards/geometry/modify.rb @@ -0,0 +1,7 @@ +# Methods to modify geometry +module OpenstudioStandards + module Geometry + # @!group Modify + + end +end diff --git a/test/create_typical/test_create_typical.rb b/test/create_typical/test_create_typical.rb new file mode 100644 index 0000000000..256683ed78 --- /dev/null +++ b/test/create_typical/test_create_typical.rb @@ -0,0 +1,15 @@ +require_relative '../helpers/minitest_helper' + +class TestCreateTypical < Minitest::Test + def setup + @create = OpenstudioStandards::CreateTypical + end + + def test_typical_building_from_model + + end + + def test_create_space_types_and_constructions + + end +end \ No newline at end of file diff --git a/test/create_typical/test_enumerations.rb b/test/create_typical/test_enumerations.rb new file mode 100644 index 0000000000..6feae5e17c --- /dev/null +++ b/test/create_typical/test_enumerations.rb @@ -0,0 +1,102 @@ +require_relative '../helpers/minitest_helper' + +class TestCreateTypicalEnumerations < Minitest::Test + def setup + @create = OpenstudioStandards::CreateTypical + end + + def test_get_doe_building_types + result = @create.get_doe_building_types + assert(result.class.to_s == 'OpenStudio::StringVector') + assert(!result.empty?) + + result = @create.get_doe_building_types(extended = true) + assert(result.class.to_s == 'OpenStudio::StringVector') + assert(!result.empty?) + end + + def test_get_deer_building_types + result = @create.get_deer_building_types + assert(result.class.to_s == 'OpenStudio::StringVector') + assert(!result.empty?) + + result = @create.get_deer_building_types(extended = true) + assert(result.class.to_s == 'OpenStudio::StringVector') + assert(!result.empty?) + end + + def test_get_building_types + result = @create.get_building_types + assert(result.class.to_s == 'OpenStudio::StringVector') + assert(!result.empty?) + + result = @create.get_building_types(extended = true) + assert(result.class.to_s == 'OpenStudio::StringVector') + assert(!result.empty?) + end + + def test_get_doe_templates + result = @create.get_doe_templates + assert(result.class.to_s == 'OpenStudio::StringVector') + assert(!result.empty?) + + result = @create.get_doe_templates(extended = true) + assert(result.class.to_s == 'OpenStudio::StringVector') + assert(!result.empty?) + end + + def test_get_deer_templates + result = @create.get_deer_templates + assert(result.class.to_s == 'OpenStudio::StringVector') + assert(!result.empty?) + + result = @create.get_deer_templates(extended = true) + assert(result.class.to_s == 'OpenStudio::StringVector') + assert(!result.empty?) + end + + def test_get_templates + result = @create.get_templates + assert(result.class.to_s == 'OpenStudio::StringVector') + assert(!result.empty?) + + result = @create.get_templates(extended = true) + assert(result.class.to_s == 'OpenStudio::StringVector') + assert(!result.empty?) + end + + def test_get_doe_climate_zones + result1 = @create.get_doe_climate_zones + assert(result1.class.to_s == 'OpenStudio::StringVector') + assert(!result1.empty?) + + result2 = @create.get_doe_climate_zones(extended = true) + assert(result2.class.to_s == 'OpenStudio::StringVector') + assert(!result2.empty?) + + result3 = @create.get_doe_climate_zones(extended = false, extra = 'ASHRAE 169-2013-0A') + assert(result3.class.to_s == 'OpenStudio::StringVector') + assert(!result3.empty?) + assert(result1.size + 1 == result3.size) + end + + def test_get_deer_climate_zones + result = @create.get_deer_climate_zones + assert(result.class.to_s == 'OpenStudio::StringVector') + assert(!result.empty?) + + result = @create.get_deer_climate_zones(extended = true) + assert(result.class.to_s == 'OpenStudio::StringVector') + assert(!result.empty?) + end + + def test_get_climate_zones + result = @create.get_climate_zones + assert(result.class.to_s == 'OpenStudio::StringVector') + assert(!result.empty?) + + result = @create.get_climate_zones(extended = true) + assert(result.class.to_s == 'OpenStudio::StringVector') + assert(!result.empty?) + end +end \ No newline at end of file diff --git a/test/create_typical/test_space_type_ratios.rb b/test/create_typical/test_space_type_ratios.rb new file mode 100644 index 0000000000..1cb23e7d3c --- /dev/null +++ b/test/create_typical/test_space_type_ratios.rb @@ -0,0 +1,22 @@ +require_relative '../helpers/minitest_helper' + +class TestCreateTypicalSpaceTypeRatios < Minitest::Test + def setup + @create = OpenstudioStandards::CreateTypical + end + + def test_get_space_types_from_building_type + building_type = 'PrimarySchool' + template = '90.1-2013' + result = @create.get_space_types_from_building_type(building_type, template) + + building_type = 'MediumOffice' + template = '90.1-2013' + result = @create.get_space_types_from_building_type(building_type, template, whole_building = true) + + building_type = 'Casa Bonita' + template = '90.1-2013' + result = @create.get_space_types_from_building_type(building_type, template) + assert(result == false) + end +end \ No newline at end of file From 3b7abc31c8bd71865e4ba56a03ba87379d7e7540 Mon Sep 17 00:00:00 2001 From: Matthew Dahlhausen Date: Wed, 13 Sep 2023 14:03:27 -0600 Subject: [PATCH 38/45] refactor create_typical methods - remove references to runner and Os_Lib_HelperMethods - add tests --- .../create_typical/create_typical.rb | 408 +++++++++--------- test/create_typical/test_create_typical.rb | 19 +- 2 files changed, 215 insertions(+), 212 deletions(-) diff --git a/lib/openstudio-standards/create_typical/create_typical.rb b/lib/openstudio-standards/create_typical/create_typical.rb index 994f618edc..a7a11e4e4e 100644 --- a/lib/openstudio-standards/create_typical/create_typical.rb +++ b/lib/openstudio-standards/create_typical/create_typical.rb @@ -6,79 +6,132 @@ module CreateTypical # create typical building from model # creates a complete energy model from model with defined geometry and standards space type assignments # + # @param template [String] standard template + # @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'. + # @param add_hvac [Boolean] Add HVAC systems to the model + # @param hvac_system_type [String] HVAC system type + # @param hvac_delivery_type [String] HVAC delivery type, how the system delivers heating or cooling to zones. + # Options are 'Forced Air' or 'Hydronic'. + # @param heating_fuel [String] The primary HVAC heating fuel type. + # Options are 'Electricity', 'NaturalGas', 'DistrictHeating', 'DistrictAmbient' + # @param service_water_heating_fuel [String] The primary service water heating fuel type. + # Options are 'Inferred', 'Electricity', 'NaturalGas', 'DistrictHeating', 'HeatPump' + # @param cooling_fuel [String] The primary HVAC cooling fuel type + # Options are 'Electricity', 'DistrictCooling', 'DistrictAmbient' + # @param kitchen_makeup [String] Source of makeup air for kitchen exhaust + # Options are 'None', 'Largest Zone', 'Adjacent' + # @param exterior_lighting_zone [String] The exterior lighting zone for exterior lighting allowance. + # Options are '0 - Undeveloped Areas Parks', '1 - Developed Areas Parks', '2 - Neighborhood', '3 - All Other Areas', '4 - High Activity' + # @param add_constructions [Boolean] Create and apply default construction set + # @param add_space_type_loads [Boolean] Populate existing standards space types in the model with internal loads + # @param add_daylighting_controls [Boolean] Add daylighting controls + # @param add_elevators [Boolean] Apply elevators directly to a space in the model instead of to a space type + # @param add_internal_mass [Boolean] Add internal mass to each space + # @param add_exterior_lights [Boolean] Add exterior lightings objects to parking, canopies, and facades + # @param onsite_parking_fraction [Double] Fraction of allowable exterior parking lighting applied. Set to 0 to add no parking lighting. + # @param add_exhaust [Boolean] Add exhaust fans to the models. Primarly kitchen exhaust fans. + # @param add_swh [Boolean] Add service water heating supply and demand objects + # @param add_thermostat [Boolean] Add thermostats to thermal zones based on the standards space type + # @param add_refrigeration [Boolean] Add refrigerated cases and walkin refrigeration + # @param modify_wkdy_op_hrs [Boolean] Modify the default weekday hours of operation + # @param wkdy_op_hrs_start_time [Double] Weekday operating hours start time. Enter as a fractional value, e.g. 5:15pm is 17.25. Only used if modify_wkdy_op_hrs is true. + # @param wkdy_op_hrs_duration [Double] Weekday operating hours duration from start time. Enter as a fractional value, e.g. 5:15pm is 17.25. Only used if modify_wkdy_op_hrs is true. + # @param modify_wknd_op_hrs [Boolean] Modify the default weekend hours of operation + # @param wknd_op_hrs_start_time [Double] Weekend operation hours start time. Enter as a fractional value, e.g. 5:15pm is 17.25. Only used if modify_wknd_op_hrs is true. + # @param wknd_op_hrs_duration [Double] Weekend operating hours duration from start time. Enter as a fractional value, e.g. 5:15pm is 17.25. Only used if modify_wknd_op_hrs is true. + # @param hoo_var_method [String] hours of operation variable method. Options are 'hours' or 'fractional'. + # @param enable_dst [Boolean] Enable daylight savings + # @param unmet_hours_tolerance_r [Double] Thermostat setpoint tolerance for unmet hours in degrees Rankine + # @param remove_objects [Boolean] Clean model of non-geometry objects. Only removes the same objects types as those added to the model. # @return [Boolean] returns true if successful, false if not - def self.typical_building_from_model(model, runner, user_arguments) - # assign the user inputs to variables - args = OsLib_HelperMethods.createRunVariables(runner, model, user_arguments, arguments(model)) - if !args then return false end - - # lookup and replace argument values from upstream measures - if args['use_upstream_args'] == true - args.each do |arg, value| - next if arg == 'use_upstream_args' # this argument should not be changed - value_from_osw = OsLib_HelperMethods.check_upstream_measure_for_arg(runner, arg) - if !value_from_osw.empty? - OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Replacing argument named #{arg} from current measure with a value of #{value_from_osw[:value]} from #{value_from_osw[:measure_name]}.") - new_val = value_from_osw[:value] - # TODO: - make code to handle non strings more robust. check_upstream_measure_for_arg coudl pass bakc the argument type - if arg == 'total_bldg_floor_area' - args[arg] = new_val.to_f - elsif arg == 'num_stories_above_grade' - args[arg] = new_val.to_f - elsif arg == 'zipcode' - args[arg] = new_val.to_i - else - args[arg] = new_val - end - end - end - end + def self.typical_building_from_model(model, + template, + climate_zone: 'Lookup From Model', + add_hvac: true, + hvac_system_type: 'Inferred', + hvac_delivery_type: 'Forced Air', + heating_fuel: 'NaturalGas', + service_water_heating_fuel: 'NaturalGas', + cooling_fuel: 'Electricity', + kitchen_makeup: 'Adjacent', + exterior_lighting_zone: '3 - All Other Areas', + add_constructions: true, + add_space_type_loads: true, + add_daylighting_controls: true, + add_elevators: true, + add_internal_mass: true, + add_exterior_lights: true, + onsite_parking_fraction: 1.0, + add_exhaust: true, + add_swh: true, + add_thermostat: true, + add_refrigeration: true, + modify_wkdy_op_hrs: false, + wkdy_op_hrs_start_time: 8.0, + wkdy_op_hrs_duration: 8.0, + modify_wknd_op_hrs: false, + wknd_op_hrs_start_time: 8.0, + wknd_op_hrs_duration: 8.0, + hoo_var_method: 'hours', + enable_dst: true, + unmet_hours_tolerance_r: 1.0, + remove_objects: true) - # validate fraction parking - fraction = OsLib_HelperMethods.checkDoubleAndIntegerArguments(runner, user_arguments, 'min' => 0.0, 'max' => 1.0, 'min_eq_bool' => true, 'max_eq_bool' => true, 'arg_array' => ['onsite_parking_fraction']) - if !fraction then return false end + # report initial condition of model + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "The building started with #{model.getModelObjects.size} objects.") - # validate unmet hours tolerance - unmet_hours_tolerance_valid = OsLib_HelperMethods.checkDoubleAndIntegerArguments(runner, user_arguments, 'min' => 0.0, 'max' => 5.0, 'min_eq_bool' => true, 'max_eq_bool' => true, 'arg_array' => ['unmet_hours_tolerance']) - if !unmet_hours_tolerance_valid then return false end + # create a new standard class + standard = Standard.build(template) + + # validate climate zone + if climate_zone == 'Lookup From Model' || climate_zone.nil? + climate_zone = standard.model_get_building_properties(model)['climate_zone'] + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Using climate zone #{climate_zone} from model") + else + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Using climate zone #{climate_zone} from user arguments") + end + if climate_zone == '' + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Could not determine climate zone from measure arguments or model.") + return false + end # validate weekday hours of operation wkdy_op_hrs_start_time_hr = nil wkdy_op_hrs_start_time_min = nil wkdy_op_hrs_duration_hr = nil wkdy_op_hrs_duration_min = nil - if args['modify_wkdy_op_hrs'] + if modify_wkdy_op_hrs # weekday start time hr - wkdy_op_hrs_start_time_hr = args['wkdy_op_hrs_start_time'].floor + wkdy_op_hrs_start_time_hr = wkdy_op_hrs_start_time.floor if wkdy_op_hrs_start_time_hr < 0 || wkdy_op_hrs_start_time_hr > 24 - OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Weekday operating hours start time hrs must be between 0 and 24. #{args['wkdy_op_hrs_start_time']} was entered.") + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Weekday operating hours start time hrs must be between 0 and 24. #{wkdy_op_hrs_start_time} was entered.") return false end # weekday start time min - wkdy_op_hrs_start_time_min = (60.0 * (args['wkdy_op_hrs_start_time'] - args['wkdy_op_hrs_start_time'].floor)).floor + wkdy_op_hrs_start_time_min = (60.0 * (wkdy_op_hrs_start_time - wkdy_op_hrs_start_time.floor)).floor if wkdy_op_hrs_start_time_min < 0 || wkdy_op_hrs_start_time_min > 59 - OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Weekday operating hours start time mins must be between 0 and 59. #{args['wkdy_op_hrs_start_time']} was entered.") + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Weekday operating hours start time mins must be between 0 and 59. #{wkdy_op_hrs_start_time} was entered.") return false end # weekday duration hr - wkdy_op_hrs_duration_hr = args['wkdy_op_hrs_duration'].floor + wkdy_op_hrs_duration_hr = wkdy_op_hrs_duration.floor if wkdy_op_hrs_duration_hr < 0 || wkdy_op_hrs_duration_hr > 24 - OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Weekday operating hours duration hrs must be between 0 and 24. #{args['wkdy_op_hrs_duration']} was entered.") + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Weekday operating hours duration hrs must be between 0 and 24. #{wkdy_op_hrs_duration} was entered.") return false end # weekday duration min - wkdy_op_hrs_duration_min = (60.0 * (args['wkdy_op_hrs_duration'] - args['wkdy_op_hrs_duration'].floor)).floor + wkdy_op_hrs_duration_min = (60.0 * (wkdy_op_hrs_duration - wkdy_op_hrs_duration.floor)).floor if wkdy_op_hrs_duration_min < 0 || wkdy_op_hrs_duration_min > 59 - OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Weekday operating hours duration mins must be between 0 and 59. #{args['wkdy_op_hrs_duration']} was entered.") + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Weekday operating hours duration mins must be between 0 and 59. #{wkdy_op_hrs_duration} was entered.") return false end # check that weekday start time plus duration does not exceed 24 hrs if (wkdy_op_hrs_start_time_hr + wkdy_op_hrs_duration_hr + (wkdy_op_hrs_start_time_min + wkdy_op_hrs_duration_min) / 60.0) > 24.0 - OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Weekday start time of #{args['wkdy_op_hrs_start']} plus duration of #{args['wkdy_op_hrs_duration']} is more than 24 hrs, hours of operation overlap midnight.") + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Weekday start time of #{wkdy_op_hrs_start} plus duration of #{wkdy_op_hrs_duration} is more than 24 hrs, hours of operation overlap midnight.") end end @@ -87,104 +140,68 @@ def self.typical_building_from_model(model, runner, user_arguments) wknd_op_hrs_start_time_min = nil wknd_op_hrs_duration_hr = nil wknd_op_hrs_duration_min = nil - if args['modify_wknd_op_hrs'] + if modify_wknd_op_hrs # weekend start time hr - wknd_op_hrs_start_time_hr = args['wknd_op_hrs_start_time'].floor + wknd_op_hrs_start_time_hr = wknd_op_hrs_start_time.floor if wknd_op_hrs_start_time_hr < 0 || wknd_op_hrs_start_time_hr > 24 - OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Weekend operating hours start time hrs must be between 0 and 24. #{args['wknd_op_hrs_start_time_change']} was entered.") + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Weekend operating hours start time hrs must be between 0 and 24. #{wknd_op_hrs_start_time} was entered.") return false end # weekend start time min - wknd_op_hrs_start_time_min = (60.0 * (args['wknd_op_hrs_start_time'] - args['wknd_op_hrs_start_time'].floor)).floor + wknd_op_hrs_start_time_min = (60.0 * (wknd_op_hrs_start_time - wknd_op_hrs_start_time.floor)).floor if wknd_op_hrs_start_time_min < 0 || wknd_op_hrs_start_time_min > 59 - OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Weekend operating hours start time mins must be between 0 and 59. #{args['wknd_op_hrs_start_time_change']} was entered.") + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Weekend operating hours start time mins must be between 0 and 59. #{wknd_op_hrs_start_time} was entered.") return false end # weekend duration hr - wknd_op_hrs_duration_hr = args['wknd_op_hrs_duration'].floor + wknd_op_hrs_duration_hr = wknd_op_hrs_duration.floor if wknd_op_hrs_duration_hr < 0 || wknd_op_hrs_duration_hr > 24 - OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Weekend operating hours duration hrs must be between 0 and 24. #{args['wknd_op_hrs_duration']} was entered.") + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Weekend operating hours duration hrs must be between 0 and 24. #{wknd_op_hrs_duration} was entered.") return false end # weekend duration min - wknd_op_hrs_duration_min = (60.0 * (args['wknd_op_hrs_duration'] - args['wknd_op_hrs_duration'].floor)).floor + wknd_op_hrs_duration_min = (60.0 * (wknd_op_hrs_duration - wknd_op_hrs_duration.floor)).floor if wknd_op_hrs_duration_min < 0 || wknd_op_hrs_duration_min > 59 - OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Weekend operating hours duration min smust be between 0 and 59. #{args['wknd_op_hrs_duration']} was entered.") + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Weekend operating hours duration min smust be between 0 and 59. #{wknd_op_hrs_duration} was entered.") return false end # check that weekend start time plus duration does not exceed 24 hrs if (wknd_op_hrs_start_time_hr + wknd_op_hrs_duration_hr + (wknd_op_hrs_start_time_min + wknd_op_hrs_duration_min) / 60.0) > 24.0 - OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Weekend start time of #{args['wknd_op_hrs_start']} plus duration of #{args['wknd_op_hrs_duration']} is more than 24 hrs, hours of operation overlap midnight.") + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Weekend start time of #{wknd_op_hrs_start} plus duration of #{wknd_op_hrs_duration} is more than 24 hrs, hours of operation overlap midnight.") end end - # report initial condition of model - initial_objects = model.getModelObjects.size - OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "The building started with #{initial_objects} objects.") - - # open channel to log messages - reset_log - - # Make the standard applier - standard = Standard.build((args['template']).to_s) - - # validate climate zone - if !args.key?('climate_zone') || args['climate_zone'] == 'Lookup From Model' - climate_zone = standard.model_get_building_properties(model)['climate_zone'] - OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Using climate zone #{climate_zone} from model") - else - climate_zone = args['climate_zone'] - OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Using climate zone #{climate_zone} from user arguments") - end - if climate_zone == '' - OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Could not determine climate zone from measure arguments or model.") + # validate unmet hours tolerance + if unmet_hours_tolerance_r < 0 + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "unmet_hours_tolerance_r must be greater than or equal to 0 Rankine.") + return false + elsif unmet_hours_tolerance_r > 5.0 + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "unmet_hours_tolerance_r must be less than or equal to 5 Rankine.") return false - end - - # if haystack_file used find the file - # todo - may want to allow NA, empty string or some other value to skip so a measure can ake this optional witht using optional measure arguments - if args['haystack_file'] - haystack_file = runner.workflow.findFile(args['haystack_file']) - if haystack_file.is_initialized - haystack_file = haystack_file.get.to_s - - # load JSON file - json = nil - File.open(haystack_file, 'r') do |file| - json = file.read - # uncomment to inspect haystack json - # puts json - end - - else - OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Did not find #{args['haystack_file']} in paths described in OSW file.") - return false - end - else - haystack_file = nil end # make sure daylight savings is turned on up prior to any sizing runs being done. - if args['enable_dst'] + if enable_dst start_date = '2nd Sunday in March' end_date = '1st Sunday in November' - runperiodctrl_daylgtsaving = model.getRunPeriodControlDaylightSavingTime - runperiodctrl_daylgtsaving.setStartDate(start_date) - runperiodctrl_daylgtsaving.setEndDate(end_date) + runperiodctrl_daylightsaving = model.getRunPeriodControlDaylightSavingTime + runperiodctrl_daylightsaving.setStartDate(start_date) + runperiodctrl_daylightsaving.setEndDate(end_date) end # add internal loads to space types - if args['add_space_type_loads'] + if add_space_type_loads # remove internal loads - if args['remove_objects'] + if remove_objects model.getSpaceLoads.sort.each do |instance| - next if instance.name.to_s.include?('Elevator') # most prototype building types model exterior elevators with name Elevator + # most prototype building types model exterior elevators with name Elevator + next if instance.name.to_s.include?('Elevator') next if instance.to_InternalMass.is_initialized next if instance.to_WaterUseEquipment.is_initialized instance.remove @@ -197,7 +214,7 @@ def self.typical_building_from_model(model, runner, user_arguments) # Don't add infiltration here; will be added later in the script test = standard.space_type_apply_internal_loads(space_type, true, true, true, true, true, false) if test == false - OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.CreateTypical', "Could not add loads for #{space_type.name}. Not expected for #{args['template']}") + OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.CreateTypical', "Could not add loads for #{space_type.name}. Not expected for #{template}") next end @@ -205,8 +222,8 @@ def self.typical_building_from_model(model, runner, user_arguments) # the last bool test it to make thermostat schedules. They are now added in HVAC section instead of here standard.space_type_apply_internal_load_schedules(space_type, true, true, true, true, true, true, false) - # extend space type name to include the args['template']. Consider this as well for load defs - space_type.setName("#{space_type.name} - #{args['template']}") + # extend space type name to include the template. Consider this as well for load defs + space_type.setName("#{space_type.name} - #{template}") OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Adding loads to space type named #{space_type.name}") end @@ -236,19 +253,20 @@ def self.typical_building_from_model(model, runner, user_arguments) OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.CreateTypical', "Can't identify building type for #{space_type.name}") end end - primary_bldg_type = building_types.key(building_types.values.max) # TODO: - this fails if no space types, or maybe just no space types with standards - lookup_building_type = standard.model_get_lookup_name(primary_bldg_type) # Used for some lookups in the standards gem + # @todo this fails if no space types, or maybe just no space types with standards + primary_bldg_type = building_types.key(building_types.values.max) + # Used for some lookups in the standards gem + lookup_building_type = standard.model_get_lookup_name(primary_bldg_type) model.getBuilding.setStandardsBuildingType(primary_bldg_type) # make construction set and apply to building - if args['add_constructions'] + if add_constructions # remove default construction sets - if args['remove_objects'] + if remove_objects model.getDefaultConstructionSets.each(&:remove) end - # TODO: - allow building type and space type specific constructions set selection. if ['SmallHotel', 'LargeHotel', 'MidriseApartment', 'HighriseApartment'].include?(primary_bldg_type) is_residential = 'Yes' occ_type = 'Residential' @@ -264,7 +282,6 @@ def self.typical_building_from_model(model, runner, user_arguments) OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Adding default construction set named #{bldg_def_const_set.name}") else OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Could not create default construction set for the building type #{lookup_building_type} in climate zone #{climate_zone}.") - log_messages_to_runner(runner, debug = true) return false end @@ -303,7 +320,7 @@ def self.typical_building_from_model(model, runner, user_arguments) end # modify the infiltration rates - if args['remove_objects'] + if remove_objects model.getSpaceInfiltrationDesignFlowRates.each(&:remove) end standard.model_apply_infiltration_standard(model) @@ -311,11 +328,10 @@ def self.typical_building_from_model(model, runner, user_arguments) # set ground temperatures from DOE prototype buildings standard.model_add_ground_temperatures(model, primary_bldg_type, climate_zone) - end # add elevators (returns ElectricEquipment object) - if args['add_elevators'] + if add_elevators # remove elevators as spaceLoads or exteriorLights model.getSpaceLoads.sort.each do |instance| @@ -341,30 +357,30 @@ def self.typical_building_from_model(model, runner, user_arguments) end # add exterior lights (returns a hash where key is lighting type and value is exteriorLights object) - if args['add_exterior_lights'] + if add_exterior_lights - if args['remove_objects'] + if remove_objects model.getExteriorLightss.sort.each do |ext_light| next if ext_light.name.to_s.include?('Fuel equipment') # some prototype building types model exterior elevators by this name ext_light.remove end end - exterior_lights = standard.model_add_typical_exterior_lights(model, args['exterior_lighting_zone'].chars[0].to_i, args['onsite_parking_fraction']) + exterior_lights = standard.model_add_typical_exterior_lights(model, exterior_lighting_zone.chars[0].to_i, onsite_parking_fraction) exterior_lights.each do |k, v| OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Adding Exterior Lights named #{v.exteriorLightsDefinition.name} with design level of #{v.exteriorLightsDefinition.designLevel} * #{OpenStudio.toNeatString(v.multiplier, 0, true)}.") end end # add_exhaust - if args['add_exhaust'] + if add_exhaust # remove exhaust objects - if args['remove_objects'] + if remove_objects model.getFanZoneExhausts.each(&:remove) end - zone_exhaust_fans = standard.model_add_exhaust(model, args['kitchen_makeup']) # second argument is strategy for finding makeup zones for exhaust zones + zone_exhaust_fans = standard.model_add_exhaust(model, kitchen_makeup) # second argument is strategy for finding makeup zones for exhaust zones zone_exhaust_fans.each do |k, v| max_flow_rate_ip = OpenStudio.convert(k.maximumFlowRate.get, 'm^3/s', 'cfm').get if v.key?(:zone_mixing) @@ -379,29 +395,33 @@ def self.typical_building_from_model(model, runner, user_arguments) end # add service water heating demand and supply - if args['add_swh'] + if add_swh # remove water use equipment and water use connections - if args['remove_objects'] + if remove_objects # TODO: - remove plant loops used for service water heating model.getWaterUseEquipments.each(&:remove) model.getWaterUseConnectionss.each(&:remove) end # Infer the SWH type - if args['swh_src'] == 'Inferred' - if args['htg_src'] == 'NaturalGas' || args['htg_src'] == 'DistrictHeating' - args['swh_src'] = 'NaturalGas' # If building has gas service, probably uses natural gas for SWH - elsif args['htg_src'] == 'Electricity' - args['swh_src'] = 'Electricity' # If building is doing space heating with electricity, probably used for SWH - elsif args['htg_src'] == 'DistrictAmbient' - args['swh_src'] = 'HeatPump' # If building has district ambient loop, it is fancy and probably uses HPs for SWH + if service_water_heating_fuel == 'Inferred' + if heating_fuel == 'NaturalGas' || heating_fuel == 'DistrictHeating' + # If building has gas service, probably uses natural gas for SWH + service_water_heating_fuel = 'NaturalGas' + elsif heating_fuel == 'Electricity' + # If building is doing space heating with electricity, probably used for SWH + service_water_heating_fuel = 'Electricity' + elsif heating_fuel == 'DistrictAmbient' + # If building has district ambient loop, it is fancy and probably uses HPs for SWH + service_water_heating_fuel = 'HeatPump' else - args['swh_src'] = nil # Use inferences built into OpenStudio Standards for each building and space type + # Use inferences built into OpenStudio Standards for each building and space type + service_water_heating_fuel = nil end end - typical_swh = standard.model_add_typical_swh(model, water_heater_fuel: args['swh_src']) + typical_swh = standard.model_add_typical_swh(model, water_heater_fuel: service_water_heating_fuel) midrise_swh_loops = [] stripmall_swh_loops = [] typical_swh.each do |loop| @@ -426,20 +446,16 @@ def self.typical_building_from_model(model, runner, user_arguments) end end - # add_daylighting_controls (since outdated measure don't have this default to true if arg not found) - if !args.has_key?('add_daylighting_controls') - args['add_daylighting_controls'] = true - end - if args['add_daylighting_controls'] + # add_daylighting_controls + if add_daylighting_controls # remove add_daylighting_controls objects - if args['remove_objects'] + if remove_objects model.getDaylightingControls.each(&:remove) end # add daylight controls, need to perform a sizing run for 2010 - if args['template'] == '90.1-2010' || args['template'] == 'ComStock 90.1-2010' + if template == '90.1-2010' || template == 'ComStock 90.1-2010' if standard.model_run_sizing_run(model, "#{Dir.pwd}/SRvt") == false - log_messages_to_runner(runner, debug = true) return false end end @@ -447,10 +463,10 @@ def self.typical_building_from_model(model, runner, user_arguments) end # add refrigeration - if args['add_refrigeration'] + if add_refrigeration # remove refrigeration equipment - if args['remove_objects'] + if remove_objects model.getRefrigerationSystems.each(&:remove) end @@ -459,9 +475,9 @@ def self.typical_building_from_model(model, runner, user_arguments) end # add internal mass - if args['add_internal_mass'] + if add_internal_mass - if args['remove_objects'] + if remove_objects model.getSpaceLoads.sort.each do |instance| next unless instance.to_InternalMass.is_initialized instance.remove @@ -472,16 +488,15 @@ def self.typical_building_from_model(model, runner, user_arguments) standard.model_add_internal_mass(model, primary_bldg_type) end - # TODO: - add slab modeling and slab insulation - - # TODO: - fuel customization for cooking and laundry + # @todo add slab modeling and slab insulation + # @todo fuel customization for cooking and laundry # works by switching some fraction of electric loads to gas if requested (assuming base load is electric) # add thermostats - if args['add_thermostat'] + if add_thermostat # remove thermostats - if args['remove_objects'] + if remove_objects model.getThermostatSetpointDualSetpoints.each(&:remove) end @@ -507,18 +522,18 @@ def self.typical_building_from_model(model, runner, user_arguments) end # add hvac system - if args['add_hvac'] + if add_hvac # remove HVAC objects - if args['remove_objects'] + if remove_objects standard.model_remove_prm_hvac(model) end - case args['system_type'] + case hvac_system_type when 'Inferred' # Get the hvac delivery type enum - hvac_delivery = case args['hvac_delivery_type'] + hvac_delivery = case hvac_delivery_type when 'Forced Air' 'air' when 'Hydronic' @@ -531,13 +546,12 @@ def self.typical_building_from_model(model, runner, user_arguments) # For each group, infer the HVAC system type. sys_groups.each do |sys_group| # Infer the primary system type - # OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "template = #{args['template']}, climate_zone = #{climate_zone}, occ_type = #{sys_group['type']}, hvac_delivery = #{hvac_delivery}, htg_src = #{args['htg_src']}, clg_src = #{args['clg_src']}, area_ft2 = #{sys_group['area_ft2']}, num_stories = #{sys_group['stories']}") sys_type, central_htg_fuel, zone_htg_fuel, clg_fuel = standard.model_typical_hvac_system_type(model, climate_zone, sys_group['type'], hvac_delivery, - args['htg_src'], - args['clg_src'], + heating_fuel, + cooling_fuel, OpenStudio.convert(sys_group['area_ft2'], 'ft^2', 'm^2').get, sys_group['stories']) @@ -552,15 +566,7 @@ def self.typical_building_from_model(model, runner, user_arguments) end # group zones - if haystack_file.nil? - # Group zones by story - bldg_zone_lists = standard.model_group_zones_by_story(model, sys_group['zones']) - else - # todo - group zones using haystack file instead of building stories - # todo - need to do something similar to use haystack to indentify secondary zones - bldg_zone_lists = standard.model_group_zones_by_story(model, sys_group['zones']) - OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "***This code will define which zones are on air loops for inferred system***") - end + bldg_zone_lists = standard.model_group_zones_by_story(model, sys_group['zones']) # On each story, add the primary system to the primary zones # and add the secondary system to any zones that are different. @@ -599,28 +605,20 @@ def self.typical_building_from_model(model, runner, user_arguments) end end - else # HVAC system_type specified - + else + # HVAC system_type specified # Group the zones by occupancy type. Only split out non-dominant groups if their total area exceeds the limit. sys_groups = standard.model_group_zones_by_type(model, OpenStudio.convert(20_000, 'ft^2', 'm^2').get) sys_groups.each do |sys_group| # group zones - if haystack_file.nil? - # Group zones by story - bldg_zone_groups = standard.model_group_zones_by_story(model, sys_group['zones']) - else - # todo - group zones using haystack file instead of building stories - # todo - need to do something similar to use haystack to indentify secondary zones - bldg_zone_groups = standard.model_group_zones_by_story(model, sys_group['zones']) - OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "***This code will define which zones are on air loops for user specified system***") - end + bldg_zone_groups = standard.model_group_zones_by_story(model, sys_group['zones']) # Add the user specified HVAC system for each story. # Single-zone systems will get one per zone. bldg_zone_groups.each do |zones| - unless model.add_cbecs_hvac_system(standard, args['system_type'], zones) - OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "HVAC system type '#{args['system_type']}' not recognized. Check input system type argument against Model.hvac.rb for valid hvac system type names.") + unless model.add_cbecs_hvac_system(standard, hvac_system_type, zones) + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "HVAC system type '#{hvac_system_type}' not recognized. Check input system type argument against Model.hvac.rb for valid hvac system type names.") return false end end @@ -629,18 +627,10 @@ def self.typical_building_from_model(model, runner, user_arguments) end # hours of operation - if args['modify_wkdy_op_hrs'] || args['modify_wknd_op_hrs'] + if modify_wkdy_op_hrs || modify_wknd_op_hrs # Infer the current hours of operation schedule for the building op_sch = standard.model_infer_hours_of_operation_building(model) - # setup hoo_var_method (should be hours or fractional) - if args.has_key?('hoo_var_method') - hoo_var_method = args['hoo_var_method'] - else - # support measures that don't supply this argument - hoo_var_method = 'hours' - end - # Convert existing schedules in the model to parametric schedules based on current hours of operation OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Generating parametric schedules from ruleset schedules using #{hoo_var_method} variable method for hours of operation fromula.") standard.model_setup_parametric_schedules(model, hoo_var_method: hoo_var_method) @@ -651,12 +641,12 @@ def self.typical_building_from_model(model, runner, user_arguments) wknd_start_time = nil wknd_end_time = nil # weekdays - if args['modify_wkdy_op_hrs'] + if modify_wkdy_op_hrs wkdy_start_time = OpenStudio::Time.new(0, wkdy_op_hrs_start_time_hr, wkdy_op_hrs_start_time_min, 0) wkdy_end_time = wkdy_start_time + OpenStudio::Time.new(0, wkdy_op_hrs_duration_hr, wkdy_op_hrs_duration_min, 0) end # weekends - if args['modify_wknd_op_hrs'] + if modify_wknd_op_hrs wknd_start_time = OpenStudio::Time.new(0, wknd_op_hrs_start_time_hr, wknd_op_hrs_start_time_min, 0) wknd_end_time = wknd_start_time + OpenStudio::Time.new(0, wknd_op_hrs_duration_hr, wknd_op_hrs_duration_min, 0) end @@ -676,12 +666,12 @@ def self.typical_building_from_model(model, runner, user_arguments) end # set hvac controls and efficiencies (this should be last model articulation element) - if args['add_hvac'] + if add_hvac # set additional properties for building props = model.getBuilding.additionalProperties - props.setFeature('hvac_system_type', (args['system_type']).to_s) + props.setFeature('hvac_system_type', hvac_system_type) - case args['system_type'] + case hvac_system_type when 'Ideal Air Loads' else @@ -690,7 +680,6 @@ def self.typical_building_from_model(model, runner, user_arguments) # Perform a sizing run if standard.model_run_sizing_run(model, "#{Dir.pwd}/SR1") == false - log_messages_to_runner(runner, debug = true) return false end @@ -708,9 +697,9 @@ def self.typical_building_from_model(model, runner, user_arguments) end # add internal mass - if args['add_internal_mass'] + if add_internal_mass - if args['remove_objects'] + if remove_objects model.getSpaceLoads.sort.each do |instance| next unless instance.to_InternalMass.is_initialized instance.remove @@ -722,14 +711,13 @@ def self.typical_building_from_model(model, runner, user_arguments) end # set unmet hours tolerance - unmet_hrs_tol_r = args['unmet_hours_tolerance'] - unmet_hrs_tol_k = OpenStudio.convert(unmet_hrs_tol_r, 'R', 'K').get + unmet_hrs_tol_k = OpenStudio.convert(unmet_hours_tolerance_r, 'R', 'K').get tolerances = model.getOutputControlReportingTolerances tolerances.setToleranceforTimeHeatingSetpointNotMet(unmet_hrs_tol_k) tolerances.setToleranceforTimeCoolingSetpointNotMet(unmet_hrs_tol_k) # remove everything but spaces, zones, and stub space types (extend as needed for additional objects, may make bool arg for this) - if args['remove_objects'] + if remove_objects model.purgeUnusedResourceObjects objects_after_cleanup = initial_objects - model.getModelObjects.size if objects_after_cleanup > 0 @@ -749,9 +737,6 @@ def self.typical_building_from_model(model, runner, user_arguments) # report final condition of model OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "The building finished with #{model.getModelObjects.size} objects.") - # log messages to info messages - log_messages_to_runner(runner, debug = false) - return true end @@ -774,12 +759,12 @@ def self.create_space_types_and_constructions(model, create_construction_set: true, set_building_defaults: true) # reporting initial condition of model - starting_spaceTypes = model.getSpaceTypes.sort - starting_constructionSets = model.getDefaultConstructionSets.sort - OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "The building started with #{starting_spaceTypes.size} space types and #{starting_constructionSets.size} construction sets.") + starting_space_types = model.getSpaceTypes.sort + starting_construction_sets = model.getDefaultConstructionSets.sort + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "The building started with #{starting_space_types.size} space types and #{starting_construction_sets.size} construction sets.") # lookup space types for specified building type (false indicates not to use whole building type only) - space_type_hash = get_space_types_from_building_type(building_type, template, false) + space_type_hash = OpenstudioStandards::CreateTypical::get_space_types_from_building_type(building_type, template, false) if space_type_hash == false OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "#{building_type} is an unexpected building type.") return false @@ -789,8 +774,10 @@ def self.create_space_types_and_constructions(model, space_type_map = {} default_space_type_name = nil space_type_hash.each do |space_type_name, hash| - next if hash[:space_type_gen] == false # space types like undeveloped and basement are skipped. - space_type_map[space_type_name] = [] # no spaces to pass in + # skip space types like undeveloped and basement + next if hash[:space_type_gen] == false + # no spaces to pass in + space_type_map[space_type_name] = [] if hash[:default] default_space_type_name = space_type_name end @@ -813,7 +800,8 @@ def self.create_space_types_and_constructions(model, # create stub space types space_type_hash.each do |space_type_name, hash| - next if hash[:space_type_gen] == false # space types like undeveloped and basement are skipped. + # skip space types like undeveloped and basement + next if hash[:space_type_gen] == false # create space type space_type = OpenStudio::Model::SpaceType.new(model) @@ -877,10 +865,10 @@ def self.create_space_types_and_constructions(model, if set_building_defaults # identify default space type - space_type_standards_info_hash = OsLib_HelperMethods.getSpaceTypeStandardsInformation(space_types_new) default_space_type = nil - space_type_standards_info_hash.each do |space_type, standards_array| - standards_space_type = standards_array[1] + space_types_new.each do |space_type| + standards_building_type = space_type.standardsBuildingType.is_initialized ? space_type.standardsBuildingType.get : nil + standards_space_type = space_type.standardsSpaceType.is_initialized ? space_type.standardsSpaceType.get : nil if default_space_type_name == standards_space_type default_space_type = space_type end diff --git a/test/create_typical/test_create_typical.rb b/test/create_typical/test_create_typical.rb index 256683ed78..cf3f121c6d 100644 --- a/test/create_typical/test_create_typical.rb +++ b/test/create_typical/test_create_typical.rb @@ -6,10 +6,25 @@ def setup end def test_typical_building_from_model - + std = Standard.build('90.1-2013') + model = std.safe_load_model("#{File.dirname(__FILE__)}/../../data/geometry/ASHRAEPrimarySchool.osm") + template = '90.1-2013' + climate_zone = 'ASHRAE 169-2013-4A' + starting_size = model.getModelObjects.size + result = @create.typical_building_from_model(model, '90.1-2013', climate_zone: climate_zone) + ending_size = model.getModelObjects.size + assert(result) + assert(starting_size < ending_size) end def test_create_space_types_and_constructions - + model = OpenStudio::Model::Model.new + building_type = 'PrimarySchool' + template = '90.1-2013' + climate_zone = 'ASHRAE 169-2013-4A' + result = @create.create_space_types_and_constructions(model, building_type, template, climate_zone) + assert(result) + assert(model.getSpaceTypes.size > 0) + assert(model.getDefaultConstructionSets.size > 0) end end \ No newline at end of file From 769d6f36b92754d9987819b1e27169b09ff54fda Mon Sep 17 00:00:00 2001 From: Matthew Dahlhausen Date: Wed, 13 Sep 2023 14:59:15 -0600 Subject: [PATCH 39/45] fix tests by adding weather file --- .../create_typical/create_typical.rb | 5 +++-- test/create_typical/test_create_typical.rb | 10 +++++++--- 2 files changed, 10 insertions(+), 5 deletions(-) diff --git a/lib/openstudio-standards/create_typical/create_typical.rb b/lib/openstudio-standards/create_typical/create_typical.rb index a7a11e4e4e..c45fde4413 100644 --- a/lib/openstudio-standards/create_typical/create_typical.rb +++ b/lib/openstudio-standards/create_typical/create_typical.rb @@ -78,7 +78,8 @@ def self.typical_building_from_model(model, remove_objects: true) # report initial condition of model - OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "The building started with #{model.getModelObjects.size} objects.") + initial_object_size = model.getModelObjects.size + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "The building started with #{initial_object_size} objects.") # create a new standard class standard = Standard.build(template) @@ -719,7 +720,7 @@ def self.typical_building_from_model(model, # remove everything but spaces, zones, and stub space types (extend as needed for additional objects, may make bool arg for this) if remove_objects model.purgeUnusedResourceObjects - objects_after_cleanup = initial_objects - model.getModelObjects.size + objects_after_cleanup = initial_object_size - model.getModelObjects.size if objects_after_cleanup > 0 OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Removing #{objects_after_cleanup} objects from model") end diff --git a/test/create_typical/test_create_typical.rb b/test/create_typical/test_create_typical.rb index cf3f121c6d..ba362e4f81 100644 --- a/test/create_typical/test_create_typical.rb +++ b/test/create_typical/test_create_typical.rb @@ -6,12 +6,16 @@ def setup end def test_typical_building_from_model - std = Standard.build('90.1-2013') - model = std.safe_load_model("#{File.dirname(__FILE__)}/../../data/geometry/ASHRAEPrimarySchool.osm") + # load model and set up weather file template = '90.1-2013' climate_zone = 'ASHRAE 169-2013-4A' + std = Standard.build(template) + model = std.safe_load_model("#{File.dirname(__FILE__)}/../../data/geometry/ASHRAEPrimarySchool.osm") + std.model_add_design_days_and_weather_file(model, climate_zone) + + # apply create typical starting_size = model.getModelObjects.size - result = @create.typical_building_from_model(model, '90.1-2013', climate_zone: climate_zone) + result = @create.typical_building_from_model(model, template, climate_zone: climate_zone) ending_size = model.getModelObjects.size assert(result) assert(starting_size < ending_size) From 2d936ae43f462df6be7b7d34c3d43883d194f9b9 Mon Sep 17 00:00:00 2001 From: Matthew Dahlhausen Date: Wed, 13 Sep 2023 19:51:28 -0600 Subject: [PATCH 40/45] minor yard syntax update --- lib/openstudio-standards/schedules/create.rb | 5 ++--- 1 file changed, 2 insertions(+), 3 deletions(-) diff --git a/lib/openstudio-standards/schedules/create.rb b/lib/openstudio-standards/schedules/create.rb index 34edb1981a..29ad0419a6 100644 --- a/lib/openstudio-standards/schedules/create.rb +++ b/lib/openstudio-standards/schedules/create.rb @@ -236,10 +236,9 @@ def self.model_create_schedule_from_rate_of_change(model, schedule_ruleset) # merge multiple schedules into one using load or other value to weight each schedules influence on the merge # # @param model [OpenStudio::Model::Model] OpenStudio model object - # @param schedule_weights_hash [Hash] Array of hashes of {OpenStudio::Model::ScheduleRuleset, Double} + # @param schedule_weights_hash [Hash] Hash of OpenStudio::Model::ScheduleRuleset, Double # @param sch_name [String] Optional name of new schedule - # @return [Hash] Hash of {OpenStudio::Model::ScheduleRuleset, Double} - # with the OpenStudio ScheduleRuleset object and the total denominator + # @return [Hash] Hash of merged schedule and the total denominator # @todo apply weights to schedule rules as well, not just winter, summer, and default profile def self.model_create_weighted_merge_schedules(model, schedule_weights_hash, sch_name: 'Merged Schedule') # get denominator for weight From c1d68cd55657cf9a3992d5194d0fb2d169aac2f7 Mon Sep 17 00:00:00 2001 From: Matthew Dahlhausen Date: Wed, 13 Sep 2023 20:21:10 -0600 Subject: [PATCH 41/45] rubocop fixes --- .../create_typical/create_typical.rb | 52 ++- .../create_typical/enumerations.rb | 7 +- .../create_typical/space_type_ratios.rb | 5 +- lib/openstudio-standards/geometry/create.rb | 351 +++++++++--------- .../geometry/information.rb | 2 +- lib/openstudio-standards/geometry/modify.rb | 1 - lib/openstudio-standards/schedules/create.rb | 2 +- .../schedules/information.rb | 2 +- lib/openstudio-standards/schedules/modify.rb | 93 +++-- 9 files changed, 266 insertions(+), 249 deletions(-) diff --git a/lib/openstudio-standards/create_typical/create_typical.rb b/lib/openstudio-standards/create_typical/create_typical.rb index c45fde4413..1ceb1c64f3 100644 --- a/lib/openstudio-standards/create_typical/create_typical.rb +++ b/lib/openstudio-standards/create_typical/create_typical.rb @@ -92,7 +92,7 @@ def self.typical_building_from_model(model, OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Using climate zone #{climate_zone} from user arguments") end if climate_zone == '' - OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "Could not determine climate zone from measure arguments or model.") + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', 'Could not determine climate zone from measure arguments or model.') return false end @@ -178,10 +178,10 @@ def self.typical_building_from_model(model, # validate unmet hours tolerance if unmet_hours_tolerance_r < 0 - OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "unmet_hours_tolerance_r must be greater than or equal to 0 Rankine.") + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', 'unmet_hours_tolerance_r must be greater than or equal to 0 Rankine.') return false elsif unmet_hours_tolerance_r > 5.0 - OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "unmet_hours_tolerance_r must be less than or equal to 5 Rankine.") + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', 'unmet_hours_tolerance_r must be less than or equal to 5 Rankine.') return false end @@ -205,6 +205,7 @@ def self.typical_building_from_model(model, next if instance.name.to_s.include?('Elevator') next if instance.to_InternalMass.is_initialized next if instance.to_WaterUseEquipment.is_initialized + instance.remove end model.getDesignSpecificationOutdoorAirs.each(&:remove) @@ -232,6 +233,7 @@ def self.typical_building_from_model(model, spaces_without_space_types = [] model.getSpaces.sort.each do |space| next if space.spaceType.is_initialized + spaces_without_space_types << space end if !spaces_without_space_types.empty? @@ -296,10 +298,12 @@ def self.typical_building_from_model(model, next unless surf.outsideBoundaryCondition == 'Outdoors' next unless surf.surfaceType == 'RoofCeiling' next if surf.construction.empty? + construction = surf.construction.get standards_info = construction.standardsInformation next if standards_info.intendedSurfaceType.empty? next unless standards_info.intendedSurfaceType.get == 'AtticFloor' + if new_construction.nil? new_construction = standard.model_find_and_add_construction(model, climate_zone_set, @@ -315,6 +319,7 @@ def self.typical_building_from_model(model, model.getSurfaces.sort.each do |surface| next if surface.outsideBoundaryCondition != 'Adiabatic' next if surface.construction.is_initialized + surface.setAdjacentSurface(surface) surface.setConstruction(surface.construction.get) surface.setOutsideBoundaryCondition('Adiabatic') @@ -337,10 +342,12 @@ def self.typical_building_from_model(model, # remove elevators as spaceLoads or exteriorLights model.getSpaceLoads.sort.each do |instance| next if !instance.name.to_s.include?('Elevator') # most prototype building types model exterior elevators with name Elevator + instance.remove end model.getExteriorLightss.sort.each do |ext_light| next if !ext_light.name.to_s.include?('Fuel equipment') # some prototype building types model exterior elevators by this name + ext_light.remove end @@ -363,6 +370,7 @@ def self.typical_building_from_model(model, if remove_objects model.getExteriorLightss.sort.each do |ext_light| next if ext_light.name.to_s.include?('Fuel equipment') # some prototype building types model exterior elevators by this name + ext_light.remove end end @@ -408,11 +416,11 @@ def self.typical_building_from_model(model, # Infer the SWH type if service_water_heating_fuel == 'Inferred' if heating_fuel == 'NaturalGas' || heating_fuel == 'DistrictHeating' - # If building has gas service, probably uses natural gas for SWH - service_water_heating_fuel = 'NaturalGas' + # If building has gas service, probably uses natural gas for SWH + service_water_heating_fuel = 'NaturalGas' elsif heating_fuel == 'Electricity' - # If building is doing space heating with electricity, probably used for SWH - service_water_heating_fuel = 'Electricity' + # If building is doing space heating with electricity, probably used for SWH + service_water_heating_fuel = 'Electricity' elsif heating_fuel == 'DistrictAmbient' # If building has district ambient loop, it is fancy and probably uses HPs for SWH service_water_heating_fuel = 'HeatPump' @@ -434,6 +442,7 @@ def self.typical_building_from_model(model, water_use_connections = [] loop.demandComponents.each do |component| next if !component.to_WaterUseConnections.is_initialized + water_use_connections << component end OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Adding #{loop.name} to the building. It has #{water_use_connections.size} water use connections.") @@ -481,6 +490,7 @@ def self.typical_building_from_model(model, if remove_objects model.getSpaceLoads.sort.each do |instance| next unless instance.to_InternalMass.is_initialized + instance.remove end end @@ -505,6 +515,7 @@ def self.typical_building_from_model(model, # create thermostat schedules # skip un-recognized space types next if standard.space_type_get_standards_data(space_type).empty? + # the last bool test it to make thermostat schedules. They are added to the model but not assigned standard.space_type_apply_internal_load_schedules(space_type, false, false, false, false, false, false, true) @@ -513,9 +524,11 @@ def self.typical_building_from_model(model, next if thermostat.name.to_s != "#{space_type.name} Thermostat" next if !thermostat.coolingSetpointTemperatureSchedule.is_initialized next if !thermostat.heatingSetpointTemperatureSchedule.is_initialized + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Assigning #{thermostat.name} to thermal zones with #{space_type.name} assigned.") space_type.spaces.sort.each do |space| next if !space.thermalZone.is_initialized + space.thermalZone.get.setThermostatSetpointDualSetpoint(thermostat) end end @@ -606,12 +619,11 @@ def self.typical_building_from_model(model, end end - else + else # HVAC system_type specified # Group the zones by occupancy type. Only split out non-dominant groups if their total area exceeds the limit. sys_groups = standard.model_group_zones_by_type(model, OpenStudio.convert(20_000, 'ft^2', 'm^2').get) sys_groups.each do |sys_group| - # group zones bldg_zone_groups = standard.model_group_zones_by_story(model, sys_group['zones']) @@ -654,12 +666,12 @@ def self.typical_building_from_model(model, # Modify hours of operation, using weekdays values for all weekdays and weekend values for Saturday and Sunday standard.schedule_ruleset_set_hours_of_operation(op_sch, - wkdy_start_time: wkdy_start_time, - wkdy_end_time: wkdy_end_time, - sat_start_time: wknd_start_time, - sat_end_time: wknd_end_time, - sun_start_time: wknd_start_time, - sun_end_time: wknd_end_time) + wkdy_start_time: wkdy_start_time, + wkdy_end_time: wkdy_end_time, + sat_start_time: wknd_start_time, + sat_end_time: wknd_end_time, + sun_start_time: wknd_start_time, + sun_end_time: wknd_end_time) # Apply new operating hours to parametric schedules to make schedules in model reflect modified hours of operation parametric_schedules = standard.model_apply_parametric_schedules(model, error_on_out_of_order: false) @@ -703,6 +715,7 @@ def self.typical_building_from_model(model, if remove_objects model.getSpaceLoads.sort.each do |instance| next unless instance.to_InternalMass.is_initialized + instance.remove end end @@ -732,7 +745,7 @@ def self.typical_building_from_model(model, manager_night_cycles.each do |night_cycle| night_cycle.setThermostatTolerance(1.9999) - night_cycle.setCyclingRunTimeControlType("Thermostat") + night_cycle.setCyclingRunTimeControlType('Thermostat') end # report final condition of model @@ -747,7 +760,7 @@ def self.typical_building_from_model(model, # @param building_type [String] standard building type # @param template [String] standard template # @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A' - # @param create_space_types [Boolean] Create space types + # @param create_space_types [Boolean] Create space types # @param create_construction_set [Boolean] Create the construction set # @param set_building_defaults [Boolean] Set the climate zone, newly generated construction set, # and first newly generated space type as the building default @@ -765,7 +778,7 @@ def self.create_space_types_and_constructions(model, OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "The building started with #{starting_space_types.size} space types and #{starting_construction_sets.size} construction sets.") # lookup space types for specified building type (false indicates not to use whole building type only) - space_type_hash = OpenstudioStandards::CreateTypical::get_space_types_from_building_type(building_type, template, false) + space_type_hash = OpenstudioStandards::CreateTypical.get_space_types_from_building_type(building_type, template, false) if space_type_hash == false OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "#{building_type} is an unexpected building type.") return false @@ -777,6 +790,7 @@ def self.create_space_types_and_constructions(model, space_type_hash.each do |space_type_name, hash| # skip space types like undeveloped and basement next if hash[:space_type_gen] == false + # no spaces to pass in space_type_map[space_type_name] = [] if hash[:default] @@ -918,4 +932,4 @@ def self.create_space_types_and_constructions(model, return true end end -end \ No newline at end of file +end diff --git a/lib/openstudio-standards/create_typical/enumerations.rb b/lib/openstudio-standards/create_typical/enumerations.rb index c99af4750d..0af0421e7e 100644 --- a/lib/openstudio-standards/create_typical/enumerations.rb +++ b/lib/openstudio-standards/create_typical/enumerations.rb @@ -260,15 +260,14 @@ def self.get_deer_climate_zones(extended = false, extra = nil) # @param extra [String] extra climate zone to append to list # @return [OpenStudio::StringVector] array of available climate zones as strings def self.get_climate_zones(extended = false, extra = nil) - # get climate_zones - if extended && extra != nil + if extended && !extra.nil? doe = get_doe_climate_zones(true, extra) deer = get_deer_climate_zones(true, nil) elsif extended doe = get_doe_climate_zones(true, nil) deer = get_deer_climate_zones(true, nil) - elsif extra != nil + elsif !extra.nil? doe = get_doe_climate_zones(false, extra) deer = get_deer_climate_zones(false, nil) else @@ -286,4 +285,4 @@ def self.get_climate_zones(extended = false, extra = nil) return array end end -end \ No newline at end of file +end diff --git a/lib/openstudio-standards/create_typical/space_type_ratios.rb b/lib/openstudio-standards/create_typical/space_type_ratios.rb index c539150aa9..df751e17f5 100644 --- a/lib/openstudio-standards/create_typical/space_type_ratios.rb +++ b/lib/openstudio-standards/create_typical/space_type_ratios.rb @@ -1,10 +1,9 @@ # Methods to create available inputs for typical models module OpenstudioStandards module CreateTypical - # create hash of space types and generic ratios of building floor area. # some building type and template combination are incompatible - # + # # @param building_type [String] standard building type # @param template [String] standard template # @param whole_building [Boolean] use a whole building space type for Office types @@ -471,4 +470,4 @@ def self.get_space_types_from_building_type(building_type, template, whole_build return hash end end -end \ No newline at end of file +end diff --git a/lib/openstudio-standards/geometry/create.rb b/lib/openstudio-standards/geometry/create.rb index 33dfb1987e..91a2fcf257 100644 --- a/lib/openstudio-standards/geometry/create.rb +++ b/lib/openstudio-standards/geometry/create.rb @@ -245,6 +245,7 @@ def self.create_bar(runner, model, bar_hash, story_multiplier_method = 'Basement effective_stories_counter = 1 stories_flat.each do |hash| next if hash[:story_type] != 'Mid' + if footprint_counter == 0 string = 'Mid' else @@ -337,12 +338,14 @@ def self.create_bar(runner, model, bar_hash, story_multiplier_method = 'Basement fixed = false vertices.each do |vertex| next if fixed + if array.include?(vertex) # create a new set of vertices new_vertices = OpenStudio::Point3dVector.new array_b = [] surface.vertices.each do |vertex_b| next if array_b.include?(vertex_b) + new_vertices << vertex_b array_b << vertex_b end @@ -378,6 +381,7 @@ def self.create_bar(runner, model, bar_hash, story_multiplier_method = 'Basement surfaces_b.each do |surface_b| next if surface_a == surface_b # dont' test against same surface + if surface_a.equalVertices(surface_b) runner.registerWarning("#{surface_a.name} and #{surface_b.name} in #{space.name} have duplicate geometry, removing #{surface_b.name}.") surface_b.remove @@ -460,11 +464,14 @@ def self.create_bar(runner, model, bar_hash, story_multiplier_method = 'Basement if bar_hash[:num_stories_below_grade] > 0 model.getBuildingStorys.sort.each do |story| next if !story.name.to_s.include?('Story B') + story.spaces.sort.each do |space| next if !new_spaces.include?(space) + space.surfaces.sort.each do |surface| next if surface.surfaceType != 'Wall' next if surface.outsideBoundaryCondition != 'Outdoors' + surface.setOutsideBoundaryCondition('Ground') end end @@ -474,7 +481,7 @@ def self.create_bar(runner, model, bar_hash, story_multiplier_method = 'Basement # set wall boundary condtions to adiabatic if using make_mid_story_surfaces_adiabatic prior to windows being made if bar_hash[:make_mid_story_surfaces_adiabatic] - runner.registerInfo("Finding non-exterior walls and setting boundary condition to adiabatic") + runner.registerInfo('Finding non-exterior walls and setting boundary condition to adiabatic') # need to organize by story incase top story is partial story # should also be only for a single bar @@ -484,16 +491,15 @@ def self.create_bar(runner, model, bar_hash, story_multiplier_method = 'Basement # gather new spaces by story new_spaces.each do |space| story = space.buildingStory.get - if story_bounding.has_key?(story) - story_bounding[story][:spaces] << space - else - story_bounding[story] = {:spaces => [space]} - end + if story_bounding.key?(story) + story_bounding[story][:spaces] << space + else + story_bounding[story] = { spaces: [space] } + end end # get bounding box for each story - story_bounding.each do |story,v| - + story_bounding.each do |story, v| # get bounding_box bounding_box = OpenStudio::BoundingBox.new v[:spaces].each do |space| @@ -511,8 +517,9 @@ def self.create_bar(runner, model, bar_hash, story_multiplier_method = 'Basement # todo - may need to look at aidiabiatc constructions in downstream measure. Some may be exterior party wall others may be interior walls v[:spaces].each do |space| space.surfaces.each do |space_surface| - next if not space_surface.surfaceType == "Wall" - next if space_surface.outsideBoundaryCondition == "Surface" # if if found a match leave it alone, don't change to adiabiatc + next if space_surface.surfaceType != 'Wall' + next if space_surface.outsideBoundaryCondition == 'Surface' # if if found a match leave it alone, don't change to adiabiatc + surface_bounding_box = OpenStudio::BoundingBox.new surface_bounding_box.addPoints(space.transformation * space_surface.vertices) surface_on_outside = false @@ -527,7 +534,7 @@ def self.create_bar(runner, model, bar_hash, story_multiplier_method = 'Basement # change if not exterior if !surface_on_outside - space_surface.setOutsideBoundaryCondition("Adiabatic") + space_surface.setOutsideBoundaryCondition('Adiabatic') missed_match_count += 1 end end @@ -544,6 +551,7 @@ def self.create_bar(runner, model, bar_hash, story_multiplier_method = 'Basement sorted_stories = {} new_spaces.each do |space| next if !space.buildingStory.is_initialized + story = space.buildingStory.get if !sorted_stories.key?(name.to_s) sorted_stories[story.name.to_s] = story @@ -579,6 +587,7 @@ def self.create_bar(runner, model, bar_hash, story_multiplier_method = 'Basement story.spaces.each do |space| next if !new_spaces.include?(space) + space.surfaces. each do |surface| # set floor to adiabatic if requited if adiabatic_floor && surface.surfaceType == 'Floor' @@ -693,20 +702,20 @@ def self.bar_hash_setup_run(runner, model, args, length, width, floor_height_si, bar_hash[:building_wwr_s] = args['wwr'] bar_hash[:building_wwr_e] = args['wwr'] bar_hash[:building_wwr_w] = args['wwr'] - + # round up non integer stoires to next integer num_stories_round_up = num_stories.ceil runner.registerInfo("Making bar with length of #{OpenStudio.toNeatString(OpenStudio.convert(length, 'm', 'ft').get, 0, true)} ft and width of #{OpenStudio.toNeatString(OpenStudio.convert(width, 'm', 'ft').get, 0, true)} ft") - + # party_walls_array to be used by orientation specific or fractional party wall values party_walls_array = [] # this is an array of arrays, where each entry is effective building story with array of directions - + if args['party_wall_stories_north'] + args['party_wall_stories_south'] + args['party_wall_stories_east'] + args['party_wall_stories_west'] > 0 - + # loop through effective number of stories add orientation specific party walls per user arguments num_stories_round_up.times do |i| test_value = i + 1 - bar_hash[:num_stories_below_grade] - + array = [] if args['party_wall_stories_north'] >= test_value array << 'north' @@ -720,23 +729,23 @@ def self.bar_hash_setup_run(runner, model, args, length, width, floor_height_si, if args['party_wall_stories_west'] >= test_value array << 'west' end - + # populate party_wall_array for this story party_walls_array << array end end - + # calculate party walls if using party_wall_fraction method if args['party_wall_fraction'] > 0 && !party_walls_array.empty? runner.registerWarning('Both orientation and fractional party wall values arguments were populated, will ignore fractional party wall input') elsif args['party_wall_fraction'] > 0 - + # orientation of long and short side of building will vary based on building rotation - + # full story ext wall area typical_length_facade_area = length * floor_height_si typical_width_facade_area = width * floor_height_si - + # top story ext wall area, may be partial story partial_story_multiplier = (1.0 - args['num_stories_above_grade'].ceil + args['num_stories_above_grade']) area_multiplier = partial_story_multiplier @@ -745,10 +754,10 @@ def self.bar_hash_setup_run(runner, model, args, length, width, floor_height_si, top_story_width = width * edge_multiplier top_story_length_facade_area = top_story_length * floor_height_si top_story_width_facade_area = top_story_width * floor_height_si - + total_exterior_wall_area = 2 * (length + width) * (args['num_stories_above_grade'].ceil - 1.0) * floor_height_si + 2 * (top_story_length + top_story_width) * floor_height_si target_party_wall_area = total_exterior_wall_area * args['party_wall_fraction'] - + width_counter = 0 width_area = 0.0 facade_area = typical_width_facade_area @@ -759,13 +768,13 @@ def self.bar_hash_setup_run(runner, model, args, length, width, floor_height_si, else facade_area = typical_width_facade_area end - + width_counter += 1 width_area += facade_area - + end width_area_remainder = target_party_wall_area - width_area - + length_counter = 0 length_area = 0.0 facade_area = typical_length_facade_area @@ -776,18 +785,18 @@ def self.bar_hash_setup_run(runner, model, args, length, width, floor_height_si, else facade_area = typical_length_facade_area end - + length_counter += 1 length_area += facade_area end length_area_remainder = target_party_wall_area - length_area - + # get rotation and best fit to adjust orientation for fraction party wall rotation = args['building_rotation'] % 360.0 # should result in value between 0 and 360 card_dir_array = [0.0, 90.0, 180.0, 270.0, 360.0] # reverse array to properly handle 45, 135, 225, and 315 best_fit = card_dir_array.reverse.min_by { |x| (x.to_f - rotation).abs } - + if ![90.0, 270.0].include? best_fit width_card_dir = ['east', 'west'] length_card_dir = ['north', 'south'] @@ -795,10 +804,10 @@ def self.bar_hash_setup_run(runner, model, args, length, width, floor_height_si, width_card_dir = ['north', 'south'] length_card_dir = ['east', 'west'] end - + # if dont' find enough on short sides if width_area_remainder <= typical_length_facade_area - + num_stories_round_up.times do |i| if i + 1 <= args['num_stories_below_grade'] party_walls_array << [] @@ -814,9 +823,9 @@ def self.bar_hash_setup_run(runner, model, args, length, width, floor_height_si, party_walls_array << [] end end - + else # use long sides instead - + num_stories_round_up.times do |i| if i + 1 <= args['num_stories_below_grade'] party_walls_array << [] @@ -832,13 +841,13 @@ def self.bar_hash_setup_run(runner, model, args, length, width, floor_height_si, party_walls_array << [] end end - + end - + # TODO: - currently won't go past making two opposing sets of walls party walls. Info and registerValue are after create_bar in measure.rb - + end - + # populate bar hash with story information bar_hash[:stories] = {} num_stories_round_up.times do |i| @@ -847,21 +856,21 @@ def self.bar_hash_setup_run(runner, model, args, length, width, floor_height_si, else party_walls = party_walls_array[i] end - + # add below_partial_story if num_stories.ceil > num_stories && i == num_stories_round_up - 2 below_partial_story = true else below_partial_story = false end - + # bottom_story_ground_exposed_floor and top_story_exterior_exposed_roof already setup as bool bar_hash[:stories]["key #{i}"] = { story_party_walls: party_walls, story_min_multiplier: 1, story_included_in_building_area: true, below_partial_story: below_partial_story, bottom_story_ground_exposed_floor: args['bottom_story_ground_exposed_floor'], top_story_exterior_exposed_roof: args['top_story_exterior_exposed_roof'] } end - + # create bar new_spaces = create_bar(runner, model, bar_hash, args['story_multiplier']) - + # check expect roof and wall area target_footprint = bar_hash[:length] * bar_hash[:width] ground_floor_area = 0.0 @@ -879,7 +888,7 @@ def self.bar_hash_setup_run(runner, model, args, length, width, floor_height_si, if ground_floor_area > target_footprint + 0.001 || roof_area > target_footprint + 0.001 # runner.registerError("Ground exposed floor or Roof area is larger than footprint, likely inter-floor surface matching and intersection error.") # return false - + # not providing adiabatic work around when top story is partial story. if args['num_stories_above_grade'].to_f != args['num_stories_above_grade'].ceil runner.registerError('Ground exposed floor or Roof area is larger than footprint, likely inter-floor surface matching and intersection error.') @@ -891,10 +900,10 @@ def self.bar_hash_setup_run(runner, model, args, length, width, floor_height_si, else match_error = false end - + # TODO: - should be able to remove this fix after OpenStudio intersection issue is fixed. At that time turn the above message into an error with return false after it if match_error - + # identify z value of top and bottom story bottom_story = nil top_story = nil @@ -912,13 +921,14 @@ def self.bar_hash_setup_run(runner, model, args, length, width, floor_height_si, top_story = nom_z end end - + # change boundary condition and intersection as needed. new_spaces.each do |space| if space.buildingStory.get.nominalZCoordinate.get > bottom_story # change floors space.surfaces.each do |surface| next if !(surface.surfaceType == 'Floor' && surface.outsideBoundaryCondition == 'Ground') + surface.setOutsideBoundaryCondition('Adiabatic') end end @@ -926,20 +936,20 @@ def self.bar_hash_setup_run(runner, model, args, length, width, floor_height_si, # change ceilings space.surfaces.each do |surface| next if !(surface.surfaceType == 'RoofCeiling' && surface.outsideBoundaryCondition == 'Outdoors') + surface.setOutsideBoundaryCondition('Adiabatic') end end end end end - + # bar_arg_check_setup def self.bar_arg_check_setup(model, runner, user_arguments, building_type_ratios = true) - # assign the user inputs to variables args = OsLib_HelperMethods.createRunVariables(runner, model, user_arguments, arguments(model)) if !args then return false end - + # add in arguments that may not be passed in if !args.key?('double_loaded_corridor') args['double_loaded_corridor'] = 'None' # use None when not in measure building type data may not contain this @@ -947,11 +957,12 @@ def self.bar_arg_check_setup(model, runner, user_arguments, building_type_ratios if !args.key?('perim_mult') args['perim_mult'] = 1.0 # will not make two bars for extended perimeter end - + # lookup and replace argument values from upstream measures if args['use_upstream_args'] == true args.each do |arg, value| next if arg == 'use_upstream_args' # this argument should not be changed + value_from_osw = OsLib_HelperMethods.check_upstream_measure_for_arg(runner, arg) if !value_from_osw.empty? runner.registerInfo("Replacing argument named #{arg} from current measure with a value of #{value_from_osw[:value]} from #{value_from_osw[:measure_name]}.") @@ -969,7 +980,7 @@ def self.bar_arg_check_setup(model, runner, user_arguments, building_type_ratios end end end - + # check expected values of double arguments fraction_args = ['wwr', 'party_wall_fraction'] if building_type_ratios @@ -978,10 +989,10 @@ def self.bar_arg_check_setup(model, runner, user_arguments, building_type_ratios fraction_args << 'bldg_type_d_fract_bldg_area' end fraction = OsLib_HelperMethods.checkDoubleAndIntegerArguments(runner, user_arguments, 'min' => 0.0, 'max' => 1.0, 'min_eq_bool' => true, 'max_eq_bool' => true, 'arg_array' => fraction_args) - + one_or_greater_args = ['num_stories_above_grade'] one_or_greater = OsLib_HelperMethods.checkDoubleAndIntegerArguments(runner, user_arguments, 'min' => 1.0, 'max' => nil, 'min_eq_bool' => true, 'max_eq_bool' => false, 'arg_array' => one_or_greater_args) - + non_neg_args = ['num_stories_below_grade', 'floor_height', 'ns_to_ew_ratio', @@ -993,37 +1004,35 @@ def self.bar_arg_check_setup(model, runner, user_arguments, building_type_ratios 'single_floor_area', 'bar_width'] non_neg = OsLib_HelperMethods.checkDoubleAndIntegerArguments(runner, user_arguments, 'min' => 0.0, 'max' => nil, 'min_eq_bool' => true, 'max_eq_bool' => false, 'arg_array' => non_neg_args) - + # return false if any errors fail if !fraction then return false end return false if !one_or_greater return false if !non_neg - + return args - end - + # bar_from_building_type_ratios # used for varieties of measures that create bar from building type ratios def self.bar_from_building_type_ratios(model, runner, user_arguments) - # prep arguments - args = bar_arg_check_setup(model,runner,user_arguments) + args = bar_arg_check_setup(model, runner, user_arguments) if !args then return false end - + # check that sum of fractions for b,c, and d is less than 1.0 (so something is left for primary building type) bldg_type_a_fract_bldg_area = 1.0 - args['bldg_type_b_fract_bldg_area'] - args['bldg_type_c_fract_bldg_area'] - args['bldg_type_d_fract_bldg_area'] if bldg_type_a_fract_bldg_area <= 0.0 runner.registerError('Primary Building Type fraction of floor area must be greater than 0. Please lower one or more of the fractions for Building Type B-D.') return false end - + # Make the standard applier standard = Standard.build((args['template']).to_s) - + # report initial condition of model runner.registerInitialCondition("The building started with #{model.getSpaces.size} spaces.") - + # determine of ns_ew needs to be mirrored mirror_ns_ew = false rotation = model.getBuilding.northAxis @@ -1032,26 +1041,26 @@ def self.bar_from_building_type_ratios(model, runner, user_arguments) elsif rotation > 45.0 && rotation < 135.0 mirror_ns_ew = true end - + # remove non-resource objects not removed by removing the building remove_non_resource_objects(runner, model) - + # rename building to infer template in downstream measure name_array = [args['template'], args['bldg_type_a']] if args['bldg_type_b_fract_bldg_area'] > 0 then name_array << args['bldg_type_b'] end if args['bldg_type_c_fract_bldg_area'] > 0 then name_array << args['bldg_type_c'] end if args['bldg_type_d_fract_bldg_area'] > 0 then name_array << args['bldg_type_d'] end model.getBuilding.setName(name_array.join('|').to_s) - + # hash to whole building type data building_type_hash = {} - + # gather data for bldg_type_a building_type_hash[args['bldg_type_a']] = {} building_type_hash[args['bldg_type_a']][:frac_bldg_area] = bldg_type_a_fract_bldg_area # building_type_hash[args['bldg_type_a']][:num_units] = args['bldg_type_a_num_units'] building_type_hash[args['bldg_type_a']][:space_types] = get_space_types_from_building_type(args['bldg_type_a'], args['template'], true) - + # gather data for bldg_type_b if args['bldg_type_b_fract_bldg_area'] > 0 building_type_hash[args['bldg_type_b']] = {} @@ -1059,7 +1068,7 @@ def self.bar_from_building_type_ratios(model, runner, user_arguments) # building_type_hash[args['bldg_type_b']][:num_units] = args['bldg_type_b_num_units'] building_type_hash[args['bldg_type_b']][:space_types] = get_space_types_from_building_type(args['bldg_type_b'], args['template'], true) end - + # gather data for bldg_type_c if args['bldg_type_c_fract_bldg_area'] > 0 building_type_hash[args['bldg_type_c']] = {} @@ -1067,7 +1076,7 @@ def self.bar_from_building_type_ratios(model, runner, user_arguments) # building_type_hash[args['bldg_type_c']][:num_units] = args['bldg_type_c_num_units'] building_type_hash[args['bldg_type_c']][:space_types] = get_space_types_from_building_type(args['bldg_type_c'], args['template'], true) end - + # gather data for bldg_type_d if args['bldg_type_d_fract_bldg_area'] > 0 building_type_hash[args['bldg_type_d']] = {} @@ -1075,39 +1084,37 @@ def self.bar_from_building_type_ratios(model, runner, user_arguments) # building_type_hash[args['bldg_type_d']][:num_units] = args['bldg_type_d_num_units'] building_type_hash[args['bldg_type_d']][:space_types] = get_space_types_from_building_type(args['bldg_type_d'], args['template'], true) end - + # call bar_from_building_space_type_ratios to generate bar bar_from_space_type_ratios(model, runner, user_arguments, args, building_type_hash) - + return true - end - + # bar_from_space_type_ratios # used for varieties of measures that create bar from space type or building type ratios # args and building_type_hash should both be nil or neither shoould be nill def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, building_type_hash = nil) - # do not setup arguments if they were already passed in to this method if args.nil? # prep arguments - args = bar_arg_check_setup(model,runner,user_arguments,false) # false stops it from checking args on used in bar_from_building_type_ratios + args = bar_arg_check_setup(model, runner, user_arguments, false) # false stops it from checking args on used in bar_from_building_type_ratios if !args then return false end - + # process arg into hash space_type_hash_name = {} args['space_type_hash_string'][0..-1].split(/, /).each { |entry| entryMap = entry.split(/=>/); value_str = entryMap[1]; space_type_hash_name[entryMap[0].strip[0..-1].to_s] = value_str.nil? ? '' : value_str.strip[0..-1].to_f } - + # create building type hasn from space type ratios building_type_hash = {} building_type_fraction_of_building = 0.0 - space_type_hash_name.each do |building_space_type,ratio| - building_type = building_space_type.split("|")[0].strip - space_type = building_space_type.split("|")[1].strip - + space_type_hash_name.each do |building_space_type, ratio| + building_type = building_space_type.split('|')[0].strip + space_type = building_space_type.split('|')[1].strip + # harvest height and circ info from get_space_types_from_building_type(building_type, template, whole_building = true) - building_type_lookup_info = get_space_types_from_building_type(building_type,args['template']) - if building_type_lookup_info.size == 0 + building_type_lookup_info = get_space_types_from_building_type(building_type, args['template']) + if building_type_lookup_info.empty? runner.registerWarning("#{building_type} looks like an invalid building type for #{args['template']}") end space_type_info_hash = {} @@ -1124,7 +1131,7 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b else runner.registerWarning("#{space_type} looks like an invalid space type for #{building_type}") end - + # extend harvested data with custom ratios from space type ratio string argument. if building_type_hash.key?(building_type) building_type_hash[building_type][:frac_bldg_area] += ratio @@ -1140,52 +1147,52 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b end building_type_fraction_of_building += ratio end - + # identify primary building type for building form defaults primary_building_type = building_type_hash.keys.first # update to choose building with highest ratio - runner.registerInfo("Creating bar with space type ratio proided as argument.") + runner.registerInfo('Creating bar with space type ratio proided as argument.') runner.registerInfo("Using building type from first ratio #{primary_building_type} as the primary building type. This is used for building form defaults.") - - # todo - confirm if this will get normalized up/down later of if I should fix or stop here instead of just a warning + + # TODO: - confirm if this will get normalized up/down later of if I should fix or stop here instead of just a warning if building_type_fraction_of_building > 1.0 runner.registerWarning("Sum of Space Type Ratio of #{building_type_fraction_of_building} is greater than the expected value of 1.0") elsif building_type_fraction_of_building < 1.0 runner.registerWarning("Sum of Space Type Ratio of #{building_type_fraction_of_building} is less than the expected value of 1.0") end - + else # else is used when bar_from_building_type_ratio is used - + # if aspect ratio, story height or wwr have argument value of 0 then use smart building type defaults primary_building_type = args['bldg_type_a'] - runner.registerInfo("Creating bar space type ratios by building type based on ratios from prototype models.") + runner.registerInfo('Creating bar space type ratios by building type based on ratios from prototype models.') runner.registerInfo("#{primary_building_type} will be used for building form defaults.") - + end - + # get defaults for the primary building type building_form_defaults = building_form_defaults(primary_building_type) - + # store list of defaulted items defaulted_args = [] - + if args['ns_to_ew_ratio'] == 0.0 args['ns_to_ew_ratio'] = building_form_defaults[:aspect_ratio] runner.registerInfo("0.0 value for aspect ratio will be replaced with smart default for #{primary_building_type} of #{building_form_defaults[:aspect_ratio]}.") end - + if args['perim_mult'] == 0.0 # if this is not defined then use default of 1.0 - if !building_form_defaults.has_key?(:perim_mult) + if !building_form_defaults.key?(:perim_mult) args['perim_mult'] = 1.0 else args['perim_mult'] = building_form_defaults[:perim_mult] end runner.registerInfo("0.0 value for minimum perimeter multiplier will be replaced with smart default for #{primary_building_type} of #{building_form_defaults[:perim_mult]}.") elsif args['perim_mult'] < 1.0 - runner.registerError("Other than the smart default value of 0, the minimum perimeter multiplier should be equal to 1.0 or greater.") + runner.registerError('Other than the smart default value of 0, the minimum perimeter multiplier should be equal to 1.0 or greater.') return false end - + if args['floor_height'] == 0.0 args['floor_height'] = building_form_defaults[:typical_story] runner.registerInfo("0.0 value for floor height will be replaced with smart default for #{primary_building_type} of #{building_form_defaults[:typical_story]}.") @@ -1196,13 +1203,13 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b args['wwr'] = building_form_defaults[:wwr] runner.registerInfo("0.0 value for window to wall ratio will be replaced with smart default for #{primary_building_type} of #{building_form_defaults[:wwr]}.") end - + # Make the standard applier - standard = Standard.build("#{args['template']}") - + standard = Standard.build((args['template']).to_s) + # report initial condition of model runner.registerInitialCondition("The building started with #{model.getSpaces.size} spaces.") - + # determine of ns_ew needs to be mirrored mirror_ns_ew = false rotation = model.getBuilding.northAxis @@ -1211,54 +1218,54 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b elsif rotation > 45.0 && rotation < 135.0 mirror_ns_ew = true end - + # remove non-resource objects not removed by removing the building remove_non_resource_objects(runner, model) - + # creating space types for requested building types building_type_hash.each do |building_type, building_type_hash| runner.registerInfo("Creating Space Types for #{building_type}.") - + # mapping building_type name is needed for a few methods building_type = standard.model_get_lookup_name(building_type) - + # create space_type_map from array sum_of_ratios = 0.0 building_type_hash[:space_types] = building_type_hash[:space_types].sort_by { |k, v| v[:ratio] }.to_h building_type_hash[:space_types].each do |space_type_name, hash| next if hash[:space_type_gen] == false # space types like undeveloped and basement are skipped. - + # create space type space_type = OpenStudio::Model::SpaceType.new(model) space_type.setStandardsBuildingType(building_type) space_type.setStandardsSpaceType(space_type_name) space_type.setName("#{building_type} #{space_type_name}") - + # set color test = standard.space_type_apply_rendering_color(space_type) # this uses openstudio-standards if !test # TODO: - once fixed in standards un-comment this # runner.registerWarning("Could not find color for #{args['template']} #{space_type.name}") end - + # extend hash to hold new space type object hash[:space_type] = space_type - + # add to sum_of_ratios counter for adjustment multiplier sum_of_ratios += hash[:ratio] end - + # store multiplier needed to adjust sum of ratios to equal 1.0 building_type_hash[:ratio_adjustment_multiplier] = 1.0 / sum_of_ratios end - + # calculate length and with of bar total_bldg_floor_area_si = OpenStudio.convert(args['total_bldg_floor_area'], 'ft^2', 'm^2').get single_floor_area_si = OpenStudio.convert(args['single_floor_area'], 'ft^2', 'm^2').get - + # store number of stories num_stories = args['num_stories_below_grade'] + args['num_stories_above_grade'] - + # handle user-assigned single floor plate size condition if args['single_floor_area'] > 0.0 footprint_si = single_floor_area_si @@ -1272,7 +1279,7 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b else footprint_si = nil end - + # populate space_types_hash space_types_hash = {} multi_height_space_types_hash = {} @@ -1282,7 +1289,7 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b end building_type_hash.each do |building_type, building_type_hash| if args['double_loaded_corridor'] == 'Primary Space Type' - + # see if building type has circulation space type, if so then merge that along with default space type into hash key in place of space type default_st = nil circ_st = nil @@ -1290,11 +1297,11 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b if hash[:default] then default_st = space_type_name end if hash[:circ] then circ_st = space_type_name end end - + # update building hash if !default_st.nil? && !circ_st.nil? runner.registerInfo("Combining #{default_st} and #{circ_st} into a group representing a double loaded corridor") - + # add new item building_type_hash[:space_types]['Double Loaded Corridor'] = {} double_loaded_st = building_type_hash[:space_types]['Double Loaded Corridor'] @@ -1309,20 +1316,20 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b double_loaded_st[:children][:default] = building_type_hash[:space_types][default_st] double_loaded_st[:children][:circ] = building_type_hash[:space_types][circ_st] double_loaded_st[:orig_ratio] = 0.0 - + # zero out ratios from old item (don't delete because I still want the space types made) building_type_hash[:space_types][default_st][:ratio] = 0.0 building_type_hash[:space_types][circ_st][:ratio] = 0.0 end end - + building_type_hash[:space_types].each do |space_type_name, hash| next if hash[:space_type_gen] == false - + space_type = hash[:space_type] ratio_of_bldg_total = hash[:ratio] * building_type_hash[:ratio_adjustment_multiplier] * building_type_hash[:frac_bldg_area] final_floor_area = ratio_of_bldg_total * total_bldg_floor_area_si # I think I can just pass ratio but passing in area is cleaner - + # only add custom height space if 0 is used for floor_height if defaulted_args.include?('floor_height') && hash.key?(:story_height) && args['custom_height_bar'] multi_height_space_types_hash[space_type] = { floor_area: final_floor_area, space_type: space_type, story_height: hash[:story_height] } @@ -1344,13 +1351,13 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b end end end - + # resort if not sorted by building type if args['space_type_sort_logic'] == 'Size' # added code to convert to hash. I use sort_by 3 other times, but those seem to be working fine as is now. space_types_hash = Hash[space_types_hash.sort_by { |k, v| v[:floor_area] }] end - + # calculate targets for testing target_areas = {} # used for checks target_areas_cust_height = 0.0 @@ -1370,7 +1377,7 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b target_areas_cust_height += v[:floor_area] end end - + # gather inputs if footprint_si.nil? footprint_si = (total_bldg_floor_area_si - target_areas_cust_height) / num_stories.to_f @@ -1378,7 +1385,7 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b floor_height_si = OpenStudio.convert(args['floor_height'], 'ft', 'm').get min_allow_size = OpenStudio.convert(15.0, 'ft', 'm').get specified_bar_width_si = OpenStudio.convert(args['bar_width'], 'ft', 'm').get - + # set custom width if specified_bar_width_si > 0 runner.registerInfo('Ignoring perimeter multiplier argument when non zero width argument is used') @@ -1401,12 +1408,12 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b # TODO: - update tests that hit this warning runner.registerWarning('Ignoring perimeter multiplier for bar that represents custom height spaces.') end - + # check if dual bar is needed dual_bar = false if specified_bar_width_si > 0.0 && args['bar_division_method'] == 'Multiple Space Types - Individual Stories Sliced' if length / width != args['ns_to_ew_ratio'] - + if args['ns_to_ew_ratio'] >= 1.0 && args['ns_to_ew_ratio'] > length / width runner.registerWarning("Can't meet target aspect ratio of #{args['ns_to_ew_ratio']}, Lowering it to #{length / width} ") args['ns_to_ew_ratio'] = length / width @@ -1435,7 +1442,7 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b elsif args['perim_mult'] > 1.0 runner.registerWarning("You selected a perimeter multiplier greater than 1.0 but didn't select a bar division method that supports this. The value for this argument will be ignored by the measure") end - + # calculations for dual bar, which later will be setup to run create_bar twice if dual_bar min_perim = 2 * width + 2 * length @@ -1445,12 +1452,12 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b dual_bar_calc_approach = nil # stretched, adiabatic_ends_bar_b, dual_bar runner.registerInfo("Minimum rectangle is #{OpenStudio.toNeatString(OpenStudio.convert(length, 'm', 'ft').get, 0, true)} ft x #{OpenStudio.toNeatString(OpenStudio.convert(width, 'm', 'ft').get, 0, true)} ft with an area of #{OpenStudio.toNeatString(OpenStudio.convert(length * width, 'm^2', 'ft^2').get, 0, true)} ft^2. Perimeter is #{OpenStudio.toNeatString(OpenStudio.convert(min_perim, 'm', 'ft').get, 0, true)} ft.") runner.registerInfo("Target dual bar perimeter is #{OpenStudio.toNeatString(OpenStudio.convert(target_perim, 'm', 'ft').get, 0, true)} ft.") - + # determine which of the three paths to hit target perimeter multiplier are possible # A use dual bar non adiabatic # B use dual bar adiabatic # C use stretched bar (requires model to miss ns/ew ratio) - + # custom quadratic equation to solve two bars with common width 2l^2 - p*l + 4a = 0 if target_perim**2 - 32 * footprint_si > 0 if specified_bar_width_si > 0 @@ -1461,7 +1468,7 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b dual_double_end_length = 0.25 * (target_perim + Math.sqrt(target_perim**2 - 32 * footprint_si)) dual_double_end_width = footprint_si / dual_double_end_length end - + # now that stretched bar is made, determine where to split it and rotate bar_a_length = (args['ns_to_ew_ratio'] * (dual_double_end_length + dual_double_end_width) - dual_double_end_width) / (1 + args['ns_to_ew_ratio']) bar_b_length = dual_double_end_length - bar_a_length @@ -1472,7 +1479,7 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b bar_a_length = 0 bar_b_length = 0 end - + if bar_a_length >= min_allow_size && bar_b_length >= min_allow_size dual_bar_calc_approach = 'dual_bar' else @@ -1505,40 +1512,40 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b dual_bar_calc_approach = 'stretched' end end - + # apply prescribed approach for stretched or dual bar if dual_bar_calc_approach == 'dual_bar' runner.registerInfo("Stretched #{OpenStudio.toNeatString(OpenStudio.convert(dual_double_end_length, 'm', 'ft').get, 0, true)} ft x #{OpenStudio.toNeatString(OpenStudio.convert(dual_double_end_width, 'm', 'ft').get, 0, true)} ft rectangle has an area of #{OpenStudio.toNeatString(OpenStudio.convert(dual_double_end_length * dual_double_end_width, 'm^2', 'ft^2').get, 0, true)} ft^2. When split in two the perimeter will be #{OpenStudio.toNeatString(OpenStudio.convert(dual_double_end_length * 2 + dual_double_end_width * 4, 'm', 'ft').get, 0, true)} ft") if (target_area - dual_double_end_length * dual_double_end_width).abs > tol_testing || (target_perim - (dual_double_end_length * 2 + dual_double_end_width * 4)).abs > tol_testing runner.registerWarning('Unexpected values for dual rectangle.') end - + runner.registerInfo("For stretched split bar, to match target ns/ew aspect ratio #{OpenStudio.toNeatString(OpenStudio.convert(bar_a_length, 'm', 'ft').get, 0, true)} ft of bar should be horizontal, with #{OpenStudio.toNeatString(OpenStudio.convert(bar_b_length, 'm', 'ft').get, 0, true)} ft turned 90 degrees. Combined area is #{OpenStudio.toNeatString(OpenStudio.convert(area_a + area_b, 'm^2', 'ft^2').get, 0, true)} ft^2. Combined perimeter is #{OpenStudio.toNeatString(OpenStudio.convert(bar_a_length * 2 + bar_b_length * 2 + dual_double_end_width * 4, 'm', 'ft').get, 0, true)} ft") if (target_area - (area_a + area_b)).abs > tol_testing || (target_perim - (bar_a_length * 2 + bar_b_length * 2 + dual_double_end_width * 4)).abs > tol_testing runner.registerWarning('Unexpected values for rotated dual rectangle') end elsif dual_bar_calc_approach == 'adiabatic_ends_bar_b' runner.registerInfo("Can't hit target perimeter with two rectangles, need to make two ends adiabatic") - + runner.registerInfo("For dual bar with adiabatic ends on bar b, to reach target aspect ratio #{OpenStudio.toNeatString(OpenStudio.convert(adiabatic_bar_a_length, 'm', 'ft').get, 0, true)} ft of bar should be north/south, with #{OpenStudio.toNeatString(OpenStudio.convert(adiabatic_bar_b_length, 'm', 'ft').get, 0, true)} ft turned 90 degrees. Combined area is #{OpenStudio.toNeatString(OpenStudio.convert(adiabatic_area_a + adiabatic_area_b, 'm^2', 'ft^2').get, 0, true)} ft^2}. Combined perimeter is #{OpenStudio.toNeatString(OpenStudio.convert(adiabatic_bar_a_length * 2 + adiabatic_bar_b_length * 2 + adiabatic_dual_double_end_width * 2, 'm', 'ft').get, 0, true)} ft") if (target_area - (adiabatic_area_a + adiabatic_area_b)).abs > tol_testing || (target_perim - (adiabatic_bar_a_length * 2 + adiabatic_bar_b_length * 2 + adiabatic_dual_double_end_width * 2)).abs > tol_testing runner.registerWarning('Unexpected values for rotated dual rectangle adiabatic ends bar b') end else # stretched bar dual_bar = false - + stretched_length = 0.25 * (target_perim + Math.sqrt(target_perim**2 - 16 * footprint_si)) stretched_width = footprint_si / stretched_length if (target_area - stretched_length * stretched_width).abs > tol_testing || (target_perim - (stretched_length + stretched_width) * 2) > tol_testing runner.registerWarning('Unexpected values for single stretched') end - + width = stretched_width length = stretched_length runner.registerInfo("Creating a dual bar to match the target minimum perimeter multiplier at the given aspect ratio would result in a bar with edge shorter than #{OpenStudio.toNeatString(OpenStudio.convert(min_allow_size, 'm', 'ft').get, 0, true)} ft. Will create a single stretched bar instead that hits the target perimeter with a slightly different ns/ew aspect ratio.") end end - + bars = {} bars['primary'] = {} if dual_bar @@ -1579,14 +1586,14 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b pri_sec_min_area = 0.0001 # m^2 space_types_hash.each do |k, v| space_type_left = v[:floor_area] - + # do not go to next space type until this one is evaulate, which may span stories until space_type_left == 0.0 || story_counter >= num_stories - + # use secondary footprint if any left if secondary_footprint_counter > 0.0 hash_area = [space_type_left, secondary_footprint_counter].min - + # confirm that the part of space type use or what is left is greater than min allowed value projected_space_type_left = space_type_left - hash_area test_a = hash_area >= pri_sec_min_area @@ -1611,7 +1618,7 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b runner.registerInfo("Shifting space types between bars to avoid sliver of #{k.name}.") end end - + # remove space if entirely used up by secondary bar if space_types_hash[k][:floor_area] <= pri_sec_tol space_types_hash.delete(k) @@ -1622,7 +1629,7 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b footprint_counter -= hash_area_pri space_type_left -= hash_area_pri end - + # reset counter when full if footprint_counter <= pri_sec_tol && secondary_footprint_counter <= pri_sec_tol # check if this is partial top floor @@ -1638,13 +1645,13 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b end end end - + # setup bar_hash and run create_bar bars['primary'][:space_types_hash] = space_types_hash bars['primary'][:args] = args v = bars['primary'] bar_hash_setup_run(runner, model, v[:args], v[:length], v[:width], v[:floor_height_si], v[:center_of_footprint], v[:space_types_hash], v[:num_stories]) - + # store offset value for multiple bars if args.key?('bar_sep_dist_mult') && args['bar_sep_dist_mult'] > 0.0 offset_val = num_stories.ceil * floor_height_si * args['bar_sep_dist_mult'] @@ -1654,7 +1661,7 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b else offset_val = num_stories.ceil * floor_height_si * 10.0 end - + if dual_bar args2 = args.clone bars['secondary'] = {} @@ -1690,13 +1697,13 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b bars['secondary'][:center_of_footprint] = OpenStudio::Point3d.new(bar_a_length * 0.5 + dual_double_end_width * 0.5 + offset_val, bar_b_length * 0.5 + dual_double_end_width * 0.5 + offset_val, 0.0) end bars['secondary'][:args] = args2 - + # setup bar_hash and run create_bar v = bars['secondary'] bar_hash_setup_run(runner, model, v[:args], v[:length], v[:width], v[:floor_height_si], v[:center_of_footprint], v[:space_types_hash], v[:num_stories]) - + end - + # future development (up against primary bar run intersection and surface matching after add all bars, avoid interior windows) # I could loop through each space type and give them unique height but for now will just take largest height and make bar of that height, which is fine for prototypes if !multi_height_space_types_hash.empty? @@ -1712,17 +1719,17 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b if args['party_wall_stories_east'] + args['party_wall_stories_west'] + args['party_wall_stories_south'] + args['party_wall_stories_north'] > 0.0 runner.registerWarning('Ignorning party wall inputs for custom height bar') end - + # disable party walls args3['party_wall_stories_east'] = 0 args3['party_wall_stories_west'] = 0 args3['party_wall_stories_south'] = 0 args3['party_wall_stories_north'] = 0 - + # setup stories args3['num_stories_below_grade'] = 0 args3['num_stories_above_grade'] = 1 - + bars['custom_height'][:floor_height_si] = floor_height_si # can make use of this when breaking out multi-height spaces bars['custom_height'][:num_stories] = num_stories bars['custom_height'][:center_of_footprint] = OpenStudio::Point3d.new(bars['primary'][:length] * -0.5 - length_cust_height * 0.5 - offset_val, 0.0, 0.0) @@ -1730,28 +1737,28 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b bars['custom_height'][:num_stories] = 1 bars['custom_height'][:space_types_hash] = multi_height_space_types_hash bars['custom_height'][:args] = args3 - + v = bars['custom_height'] bar_hash_setup_run(runner, model, v[:args], v[:length], v[:width], v[:floor_height_si], v[:center_of_footprint], v[:space_types_hash], v[:num_stories]) end - + # diagnostic log sum_actual = 0.0 sum_target = 0.0 throw_error = false - + # check expected floor areas against actual model.getSpaceTypes.sort.each do |space_type| next if !target_areas.key? space_type # space type in model not part of building type(s), maybe issue warning - + # convert to IP actual_ip = OpenStudio.convert(space_type.floorArea, 'm^2', 'ft^2').get target_ip = OpenStudio.convert(target_areas[space_type], 'm^2', 'ft^2').get sum_actual += actual_ip sum_target += target_ip - + if (space_type.floorArea - target_areas[space_type]).abs >= 1.0 - + if !args['bar_division_method'].include? 'Single Space Type' runner.registerError("#{space_type.name} doesn't have the expected floor area (actual #{OpenStudio.toNeatString(actual_ip, 0, true)} ft^2, target #{OpenStudio.toNeatString(target_ip, 0, true)} ft^2)") throw_error = true @@ -1759,16 +1766,16 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b # will see this if use Single Space type division method on multi-use building or single building type without whole building space type runner.registerWarning("#{space_type.name} doesn't have the expected floor area (actual #{OpenStudio.toNeatString(actual_ip, 0, true)} ft^2, target #{OpenStudio.toNeatString(target_ip, 0, true)} ft^2)") end - + end end - + # report summary then throw error if throw_error runner.registerError("Sum of actual floor area is #{sum_actual} ft^2, sum of target floor area is #{sum_target}.") return false end - + # check party wall fraction by looping through surfaces if args['party_wall_fraction'] > 0 actual_ext_wall_area = model.getBuilding.exteriorWallArea @@ -1776,13 +1783,14 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b model.getSurfaces.sort.each do |surface| next if surface.outsideBoundaryCondition != 'Adiabatic' next if surface.surfaceType != 'Wall' + actual_party_wall_area += surface.grossArea * surface.space.get.multiplier end actual_party_wall_fraction = actual_party_wall_area / (actual_party_wall_area + actual_ext_wall_area) runner.registerInfo("Target party wall fraction is #{args['party_wall_fraction']}. Realized fraction is #{actual_party_wall_fraction.round(2)}") runner.registerValue('party_wall_fraction_actual', actual_party_wall_fraction) end - + # check ns/ew aspect ratio (harder to check when party walls are added) wall_and_window_by_orientation = OsLib_Geometry.getExteriorWindowAndWllAreaByOrientation(model, model.getSpaces) wall_ns = (wall_and_window_by_orientation['northWall'] + wall_and_window_by_orientation['southWall']) @@ -1795,7 +1803,7 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b # for now using perimeter of ground floor and average story area (building area / num_stories) runner.registerValue('floor_area_to_perim_ratio', model.getBuilding.floorArea / (OsLib_Geometry.calculate_perimeter(model) * num_stories)) runner.registerValue('bar_width_output', OpenStudio.convert(bars['primary'][:width], 'm', 'ft').get, 'ft') - + if args['party_wall_fraction'] > 0 || args['party_wall_stories_north'] > 0 || args['party_wall_stories_south'] > 0 || args['party_wall_stories_east'] > 0 || args['party_wall_stories_west'] > 0 runner.registerInfo('Target facade area by orientation not validated when party walls are applied') elsif args['num_stories_above_grade'] != args['num_stories_above_grade'].ceil @@ -1807,7 +1815,7 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b elsif args['bar_width'] > 0 runner.registerInfo('Target facade area by orientation not validated when a dedicated custom bar width is defined') else - + # adjust length versus width based on building rotation if mirror_ns_ew wall_target_ns_ip = 2 * OpenStudio.convert(width, 'm', 'ft').get * args['perim_mult'] * args['num_stories_above_grade'] * args['floor_height'] @@ -1829,7 +1837,7 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b return false end end - + # test for excessive exterior roof area (indication of problem with intersection and or surface matching) ext_roof_area = model.getBuilding.exteriorSurfaceArea - model.getBuilding.exteriorWallArea expected_roof_area = args['total_bldg_floor_area'] / (args['num_stories_above_grade'] + args['num_stories_below_grade']).to_f @@ -1837,19 +1845,18 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b runner.registerError('Roof area larger than expected, may indicate problem with inter-floor surface intersection or matching.') return false end - + # set building rotation initial_rotation = model.getBuilding.northAxis if args['building_rotation'] != initial_rotation model.getBuilding.setNorthAxis(args['building_rotation']) runner.registerInfo("Set Building Rotation to #{model.getBuilding.northAxis}. Rotation altered after geometry generation is completed, as a result party wall orientation and aspect ratio may not reflect input values.") end - + # report final condition of model runner.registerFinalCondition("The building finished with #{model.getSpaces.size} spaces.") - + return true end - end -end \ No newline at end of file +end diff --git a/lib/openstudio-standards/geometry/information.rb b/lib/openstudio-standards/geometry/information.rb index 04d56bc864..1ed9f081ed 100644 --- a/lib/openstudio-standards/geometry/information.rb +++ b/lib/openstudio-standards/geometry/information.rb @@ -16,4 +16,4 @@ def self.calc_aspect_ratio(area, perimeter) return aspect_ratio end end -end \ No newline at end of file +end diff --git a/lib/openstudio-standards/geometry/modify.rb b/lib/openstudio-standards/geometry/modify.rb index 7cb8d4ba73..0af2e7a2a2 100644 --- a/lib/openstudio-standards/geometry/modify.rb +++ b/lib/openstudio-standards/geometry/modify.rb @@ -2,6 +2,5 @@ module OpenstudioStandards module Geometry # @!group Modify - end end diff --git a/lib/openstudio-standards/schedules/create.rb b/lib/openstudio-standards/schedules/create.rb index 29ad0419a6..b6633c890f 100644 --- a/lib/openstudio-standards/schedules/create.rb +++ b/lib/openstudio-standards/schedules/create.rb @@ -361,4 +361,4 @@ def self.model_create_weighted_merge_schedules(model, schedule_weights_hash, sch return result end end -end \ No newline at end of file +end diff --git a/lib/openstudio-standards/schedules/information.rb b/lib/openstudio-standards/schedules/information.rb index 93b53ea547..0e7bb43830 100644 --- a/lib/openstudio-standards/schedules/information.rb +++ b/lib/openstudio-standards/schedules/information.rb @@ -73,4 +73,4 @@ def self.schedule_ruleset_timeseries(schedule_ruleset) return timeseries end end -end \ No newline at end of file +end diff --git a/lib/openstudio-standards/schedules/modify.rb b/lib/openstudio-standards/schedules/modify.rb index cc42b14ea4..4476fa594c 100644 --- a/lib/openstudio-standards/schedules/modify.rb +++ b/lib/openstudio-standards/schedules/modify.rb @@ -87,7 +87,7 @@ def self.schedule_ruleset_conditional_adjust_value(schedule_ruleset, test_value, profile.addValue(times[i], [sch_value * adjust_value, floor_value].max) when 'Sum' # take the max of the floor or resulting value - profile.addValue(times[i], [sch_value + adjust_value, floor_value].max) + profile.addValue(times[i], [sch_value + adjust_value, floor_value].max) end i += 1 end @@ -211,10 +211,10 @@ def self.schedule_ruleset_adjust_hours_of_operation(schedule_ruleset, options = 'summer' => false, 'winter' => false } - + # merge user inputs with defaults options = defaults.merge(options) - + # grab schedule out of argument if schedule_ruleset.to_ScheduleRuleset.is_initialized schedule = schedule_ruleset.to_ScheduleRuleset.get @@ -222,21 +222,21 @@ def self.schedule_ruleset_adjust_hours_of_operation(schedule_ruleset, options = OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.Schedules.Modify', "schedule_ruleset_adjust_hours_of_operation only applies to ScheduleRuleset objects. Skipping #{schedule.name}") return nil end - + # array of all profiles to change profiles = [] - + # push default profiles to array if options['default'] default_rule = schedule.defaultDaySchedule profiles << default_rule end - + # push profiles to array rules = schedule.scheduleRules rules.each do |rule| day_sch = rule.daySchedule - + # if any day requested also exists in the rule, then it will be altered alter_rule = false if rule.applyMonday && rule.applyMonday == options['mon'] then alter_rule = true end @@ -246,14 +246,14 @@ def self.schedule_ruleset_adjust_hours_of_operation(schedule_ruleset, options = if rule.applyFriday && rule.applyFriday == options['fri'] then alter_rule = true end if rule.applySaturday && rule.applySaturday == options['sat'] then alter_rule = true end if rule.applySunday && rule.applySunday == options['sun'] then alter_rule = true end - + # TODO: - add in logic to warn user about conflicts where a single rule has conflicting tests - + if alter_rule profiles << day_sch end end - + # add design days to array if options['summer'] summer_design = schedule.summerDesignDaySchedule @@ -263,13 +263,13 @@ def self.schedule_ruleset_adjust_hours_of_operation(schedule_ruleset, options = winter_design = schedule.winterDesignDaySchedule profiles << winter_design end - + # give info messages as I change specific profiles OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.Schedules.Modify', "Adjusting #{schedule.name}") - + # rename schedule schedule.setName("#{schedule.name} - extend #{options['delta_length_hoo']} shift #{options['shift_hoo']}") - + # break time args into hours and minutes start_hoo_hours = (options['base_start_hoo']).to_i start_hoo_minutes = (((options['base_start_hoo']) - (options['base_start_hoo']).to_i) * 60).to_i @@ -279,7 +279,7 @@ def self.schedule_ruleset_adjust_hours_of_operation(schedule_ruleset, options = delta_minutes = (((options['delta_length_hoo']) - (options['delta_length_hoo']).to_i) * 60).to_i shift_hours = (options['shift_hoo']).to_i shift_minutes = (((options['shift_hoo']) - (options['shift_hoo']).to_i) * 60).to_i - + # time objects to use in measure time_0 = OpenStudio::Time.new(0, 0, 0, 0) time_1_min = OpenStudio::Time.new(0, 0, 1, 0) # add this to avoid times in day profile less than this @@ -289,7 +289,7 @@ def self.schedule_ruleset_adjust_hours_of_operation(schedule_ruleset, options = finish_hoo_time = OpenStudio::Time.new(0, finish_hoo_hours, finish_hoo_minutes, 0) delta_time = OpenStudio::Time.new(0, delta_hours, delta_minutes, 0) # not used shift_time = OpenStudio::Time.new(0, shift_hours, shift_minutes, 0) - + # calculations if options['base_start_hoo'] <= options['base_finish_hoo'] base_opp_day_length = options['base_finish_hoo'] - options['base_start_hoo'] @@ -305,7 +305,7 @@ def self.schedule_ruleset_adjust_hours_of_operation(schedule_ruleset, options = adjusted_opp_day_length = base_opp_day_length + options['delta_length_hoo'] hoo_time_multiplier = adjusted_opp_day_length / base_opp_day_length non_hoo_time_multiplier = (24 - adjusted_opp_day_length) / (24 - base_opp_day_length) - + # check for invalid input if adjusted_opp_day_length < 0 OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.Schedules.Modify', 'Requested hours of operation adjustment results in an invalid negative hours of operation') @@ -316,24 +316,24 @@ def self.schedule_ruleset_adjust_hours_of_operation(schedule_ruleset, options = OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.Schedules.Modify', 'Requested hours of operation adjustment results in more than 24 hours of operation') return false end - + # making some temp objects to avoid having to deal with wrap around for change of hoo times mid_hoo < start_hoo_time ? (adj_mid_hoo = mid_hoo + time_24) : (adj_mid_hoo = mid_hoo) finish_hoo_time < adj_mid_hoo ? (adj_finish_hoo_time = finish_hoo_time + time_24) : (adj_finish_hoo_time = finish_hoo_time) mid_non_hoo < adj_finish_hoo_time ? (adj_mid_non_hoo = mid_non_hoo + time_24) : (adj_mid_non_hoo = mid_non_hoo) adj_start = start_hoo_time + time_24 # not used - + # edit profiles profiles.each do |day_sch| times = day_sch.times values = day_sch.values - + # in this case delete all values outside of # todo - may need similar logic if exactly 0 hours if adjusted_opp_day_length == 24 start_val = day_sch.getValue(start_hoo_time) finish_val = day_sch.getValue(finish_hoo_time) - + # remove times out of range that should not be reference or compressed if start_hoo_time < finish_hoo_time times.each do |time| @@ -342,9 +342,9 @@ def self.schedule_ruleset_adjust_hours_of_operation(schedule_ruleset, options = end end # add in values - day_sch.addValue(start_hoo_time,start_val) - day_sch.addValue(finish_hoo_time,finish_val) - day_sch.addValue(time_24,[start_val,finish_val].max) + day_sch.addValue(start_hoo_time, start_val) + day_sch.addValue(finish_hoo_time, finish_val) + day_sch.addValue(time_24, [start_val, finish_val].max) else times.each do |time| if time > start_hoo_time && time <= finish_hoo_time @@ -352,41 +352,41 @@ def self.schedule_ruleset_adjust_hours_of_operation(schedule_ruleset, options = end end # add in values - day_sch.addValue(finish_hoo_time,finish_val) - day_sch.addValue(start_hoo_time,start_val) - day_sch.addValue(time_24,[values.first,values.last].max) + day_sch.addValue(finish_hoo_time, finish_val) + day_sch.addValue(start_hoo_time, start_val) + day_sch.addValue(time_24, [values.first, values.last].max) end - + end - + times = day_sch.times values = day_sch.values - + # arrays for values to avoid overlap conflict of times new_times = [] new_values = [] - + # this is to store what datapoint will be first after midnight, and what the value at that time should be min_time_new = time_24 min_time_value = nil - + # flag if found time at 24 found_24_or_0 = false - + # push times to array times.each do |time| # create logic for four possible quadrants. Assume any quadrant can pass over 24/0 threshold time < start_hoo_time ? (temp_time = time + time_24) : (temp_time = time) - + # calculate change in time do to hoo delta if temp_time <= adj_finish_hoo_time expand_time = (temp_time - adj_mid_hoo) * hoo_time_multiplier - (temp_time - adj_mid_hoo) else expand_time = (temp_time - adj_mid_non_hoo) * non_hoo_time_multiplier - (temp_time - adj_mid_non_hoo) end - + new_time = time + shift_time + expand_time - + # adjust wrap around times if new_time < time_0 new_time += time_24 @@ -394,7 +394,7 @@ def self.schedule_ruleset_adjust_hours_of_operation(schedule_ruleset, options = new_time -= time_24 end new_times << new_time - + # see which new_time has the lowest value. Then add a value at 24 equal to that if !found_24_or_0 && new_time <= min_time_new min_time_new = new_time @@ -409,27 +409,27 @@ def self.schedule_ruleset_adjust_hours_of_operation(schedule_ruleset, options = found_24_or_0 = true end end - + # push values to array values.each do |value| new_values << value end - + # add value for what will be 24 new_times << time_24 new_values << min_time_value - + new_time_val_hash = {} - new_times.each_with_index do |time,i| - new_time_val_hash[time.totalHours] = {:time => time, :value => new_values[i]} + new_times.each_with_index do |time, i| + new_time_val_hash[time.totalHours] = { time: time, value: new_values[i] } end - + # clear values day_sch.clearValues - + new_time_val_hash = Hash[new_time_val_hash.sort] prev_time = nil - new_time_val_hash.sort.each do |hours,time_val| + new_time_val_hash.sort.each do |hours, time_val| if prev_time.nil? || time_val[:time] - prev_time > time_1_min day_sch.addValue(time_val[:time], time_val[:value]) prev_time = time_val[:time] @@ -437,10 +437,9 @@ def self.schedule_ruleset_adjust_hours_of_operation(schedule_ruleset, options = OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.Schedules.Modify', "Time step in #{day_sch.name} between #{prev_time.toString} and #{time_val[:time].toString} is too small to support, not adding value.") end end - end - + return schedule end end -end \ No newline at end of file +end From abcb73d074302df9fcf8c0920074c60999eedff6 Mon Sep 17 00:00:00 2001 From: Matthew Dahlhausen Date: Wed, 13 Sep 2023 21:00:27 -0600 Subject: [PATCH 42/45] merge ComStock changes to create typical --- .../create_typical/create_typical.rb | 84 ++++++++++++++++--- .../create_typical/enumerations.rb | 11 +++ .../create_typical/space_type_ratios.rb | 57 +++++-------- lib/openstudio-standards/geometry/create.rb | 11 +-- 4 files changed, 109 insertions(+), 54 deletions(-) diff --git a/lib/openstudio-standards/create_typical/create_typical.rb b/lib/openstudio-standards/create_typical/create_typical.rb index 1ceb1c64f3..b87a4cb1b1 100644 --- a/lib/openstudio-standards/create_typical/create_typical.rb +++ b/lib/openstudio-standards/create_typical/create_typical.rb @@ -23,6 +23,8 @@ module CreateTypical # @param exterior_lighting_zone [String] The exterior lighting zone for exterior lighting allowance. # Options are '0 - Undeveloped Areas Parks', '1 - Developed Areas Parks', '2 - Neighborhood', '3 - All Other Areas', '4 - High Activity' # @param add_constructions [Boolean] Create and apply default construction set + # @param wall_construction_type [String] wall construction type. + # Options are 'Inferred', 'Mass', 'Metal Building', 'WoodFramed', 'SteelFramed' # @param add_space_type_loads [Boolean] Populate existing standards space types in the model with internal loads # @param add_daylighting_controls [Boolean] Add daylighting controls # @param add_elevators [Boolean] Apply elevators directly to a space in the model instead of to a space type @@ -56,6 +58,7 @@ def self.typical_building_from_model(model, kitchen_makeup: 'Adjacent', exterior_lighting_zone: '3 - All Other Areas', add_constructions: true, + wall_construction_type: 'Inferred', add_space_type_loads: true, add_daylighting_controls: true, add_elevators: true, @@ -262,6 +265,15 @@ def self.typical_building_from_model(model, lookup_building_type = standard.model_get_lookup_name(primary_bldg_type) model.getBuilding.setStandardsBuildingType(primary_bldg_type) + # set FC factor constructions before adding other constructions + standard.model_set_below_grade_wall_constructions(model, lookup_building_type, climate_zone) + standard.model_set_floor_constructions(model, lookup_building_type, climate_zone) + if model.getFFactorGroundFloorConstructions.empty? + OpenStudio.logFree(OpenStudio::Info, 'Unable to determine FC factor value to use. Using default ground construction instead.') + else + OpenStudio.logFree(OpenStudio::Info, 'Set FC factor constructions for slab and below grade walls.') + end + # make construction set and apply to building if add_constructions @@ -280,7 +292,9 @@ def self.typical_building_from_model(model, bldg_def_const_set = standard.model_add_construction_set(model, climate_zone, lookup_building_type, nil, is_residential) if bldg_def_const_set.is_initialized bldg_def_const_set = bldg_def_const_set.get - if is_residential then bldg_def_const_set.setName("Res #{bldg_def_const_set.name}") end + if is_residential == 'Yes' + bldg_def_const_set.setName("Res #{bldg_def_const_set.name}") + end model.getBuilding.setDefaultConstructionSet(bldg_def_const_set) OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Adding default construction set named #{bldg_def_const_set.name}") else @@ -288,6 +302,46 @@ def self.typical_building_from_model(model, return false end + # Replace the construction of exterior walls with user-specified wall construction type + unless wall_construction_type == 'Inferred' + # Check that a default exterior construction set is defined + if bldg_def_const_set.defaultExteriorSurfaceConstructions.empty? + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', 'Default construction set has no default exterior surface constructions.') + return false + end + ext_surf_consts = bldg_def_const_set.defaultExteriorSurfaceConstructions.get + + # Check that a default exterior wall is defined + if ext_surf_consts.wallConstruction.empty? + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', 'Default construction set has no default exterior wall construction.') + return false + end + old_construction = ext_surf_consts.wallConstruction.get + standards_info = old_construction.standardsInformation + + # Get the old wall construction type + if standards_info.standardsConstructionType.empty? + old_wall_construction_type = 'Not defined' + else + old_wall_construction_type = standards_info.standardsConstructionType.get + end + + # Modify the default wall construction if different from measure input + if old_wall_construction_type == wall_construction_type + # Don’t modify if the default matches the user-specified wall construction type + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Exterior wall construction type #{wall_construction_type} is the default for this building type.") + else + climate_zone_set = standard.model_find_climate_zone_set(model, climate_zone) + new_construction = standard.model_find_and_add_construction(model, + climate_zone_set, + 'ExteriorWall', + wall_construction_type, + occ_type) + ext_surf_consts.setWallConstruction(new_construction) + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Set exterior wall construction to #{new_construction.name}, replacing building type default #{old_construction.name}.") + end + end + # Replace the construction of any outdoor-facing "AtticFloor" surfaces # with the "ExteriorRoof" - "IEAD" construction for the specific climate zone and template. # This prevents creation of buildings where the DOE Prototype building construction set @@ -408,7 +462,7 @@ def self.typical_building_from_model(model, # remove water use equipment and water use connections if remove_objects - # TODO: - remove plant loops used for service water heating + # @todo remove plant loops used for service water heating model.getWaterUseEquipments.each(&:remove) model.getWaterUseConnectionss.each(&:remove) end @@ -465,7 +519,7 @@ def self.typical_building_from_model(model, # add daylight controls, need to perform a sizing run for 2010 if template == '90.1-2010' || template == 'ComStock 90.1-2010' - if standard.model_run_sizing_run(model, "#{Dir.pwd}/SRvt") == false + if standard.model_run_sizing_run(model, "#{Dir.pwd}/create_typical_building_from_model_SR0") == false return false end end @@ -580,11 +634,11 @@ def self.typical_building_from_model(model, end # group zones - bldg_zone_lists = standard.model_group_zones_by_story(model, sys_group['zones']) + story_zone_lists = standard.model_group_zones_by_story(model, sys_group['zones']) # On each story, add the primary system to the primary zones # and add the secondary system to any zones that are different. - bldg_zone_lists.each do |story_group| + story_zone_lists.each do |story_group| # Differentiate primary and secondary zones, based on # operating hours and internal loads (same as 90.1 PRM) pri_sec_zone_lists = standard.model_differentiate_primary_secondary_thermal_zones(model, story_group) @@ -625,11 +679,11 @@ def self.typical_building_from_model(model, sys_groups = standard.model_group_zones_by_type(model, OpenStudio.convert(20_000, 'ft^2', 'm^2').get) sys_groups.each do |sys_group| # group zones - bldg_zone_groups = standard.model_group_zones_by_story(model, sys_group['zones']) + story_zone_groups = standard.model_group_zones_by_story(model, sys_group['zones']) # Add the user specified HVAC system for each story. # Single-zone systems will get one per zone. - bldg_zone_groups.each do |zones| + story_zone_groups.each do |zones| unless model.add_cbecs_hvac_system(standard, hvac_system_type, zones) OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CreateTypical', "HVAC system type '#{hvac_system_type}' not recognized. Check input system type argument against Model.hvac.rb for valid hvac system type names.") return false @@ -645,7 +699,7 @@ def self.typical_building_from_model(model, op_sch = standard.model_infer_hours_of_operation_building(model) # Convert existing schedules in the model to parametric schedules based on current hours of operation - OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Generating parametric schedules from ruleset schedules using #{hoo_var_method} variable method for hours of operation fromula.") + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Generating parametric schedules from ruleset schedules using #{hoo_var_method} variable method for hours of operation formula.") standard.model_setup_parametric_schedules(model, hoo_var_method: hoo_var_method) # Create start and end times from start time and duration supplied @@ -692,7 +746,7 @@ def self.typical_building_from_model(model, standard.model_apply_prm_sizing_parameters(model) # Perform a sizing run - if standard.model_run_sizing_run(model, "#{Dir.pwd}/SR1") == false + if standard.model_run_sizing_run(model, "#{Dir.pwd}/create_typical_building_from_model_SR1") == false return false end @@ -742,12 +796,17 @@ def self.typical_building_from_model(model, # change night cycling control to "Thermostat" cycling and increase thermostat tolerance to 1.99999 manager_night_cycles = model.getAvailabilityManagerNightCycles OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Changing thermostat tollerance to 1.99999 for #{manager_night_cycles.size} night cycle manager objects.") - manager_night_cycles.each do |night_cycle| night_cycle.setThermostatTolerance(1.9999) night_cycle.setCyclingRunTimeControlType('Thermostat') end + # disable HVAC Sizing Simulation for Sizing Periods, not used for the type of PlantLoop sizing used in ComStock + if model.version >= OpenStudio::VersionString.new('3.0.0') + sim_control = model.getSimulationControl + sim_control.setDoHVACSizingSimulationforSizingPeriodsNoFail(false) + end + # report final condition of model OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "The building finished with #{model.getModelObjects.size} objects.") @@ -804,6 +863,11 @@ def self.create_space_types_and_constructions(model, # mapping building_type name is needed for a few methods lookup_building_type = standard.model_get_lookup_name(building_type) + # remap small medium and large office to office + if building_type.include?('Office') + building_type = 'Office' + end + # get array of new space types space_types_new = [] diff --git a/lib/openstudio-standards/create_typical/enumerations.rb b/lib/openstudio-standards/create_typical/enumerations.rb index 0af0421e7e..b1c883c208 100644 --- a/lib/openstudio-standards/create_typical/enumerations.rb +++ b/lib/openstudio-standards/create_typical/enumerations.rb @@ -160,6 +160,17 @@ def self.get_deer_templates(extended = false) array << 'DEER 2075' end + array << 'ComStock DEER Pre-1975' + array << 'ComStock DEER 1985' + array << 'ComStock DEER 1996' + array << 'ComStock DEER 2003' + array << 'ComStock DEER 2007' + array << 'ComStock DEER 2011' + array << 'ComStock DEER 2014' + array << 'ComStock DEER 2015' + array << 'ComStock DEER 2017' + array << 'ComStock DEER 2020' + return array end diff --git a/lib/openstudio-standards/create_typical/space_type_ratios.rb b/lib/openstudio-standards/create_typical/space_type_ratios.rb index df751e17f5..b9746718ce 100644 --- a/lib/openstudio-standards/create_typical/space_type_ratios.rb +++ b/lib/openstudio-standards/create_typical/space_type_ratios.rb @@ -151,38 +151,21 @@ def self.get_space_types_from_building_type(building_type, template, whole_build end end elsif building_type == 'SmallHotel' - if ['DOE Ref Pre-1980', 'DOE Ref 1980-2004', 'ComStock DOE Ref Pre-1980', 'ComStock DOE Ref 1980-2004'].include?(template) - hash['Corridor'] = { ratio: 0.1313, space_type_gen: true, default: false, circ: true } - hash['Elec/MechRoom'] = { ratio: 0.0038, space_type_gen: true, default: false } - hash['ElevatorCore'] = { ratio: 0.0113, space_type_gen: true, default: false } - hash['Exercise'] = { ratio: 0.0081, space_type_gen: true, default: false } - hash['GuestLounge'] = { ratio: 0.0406, space_type_gen: true, default: false } - hash['GuestRoom'] = { ratio: 0.6313, space_type_gen: true, default: true } - hash['Laundry'] = { ratio: 0.0244, space_type_gen: true, default: false } - hash['Mechanical'] = { ratio: 0.0081, space_type_gen: true, default: false } - hash['Meeting'] = { ratio: 0.0200, space_type_gen: true, default: false } - hash['Office'] = { ratio: 0.0325, space_type_gen: true, default: false } - hash['PublicRestroom'] = { ratio: 0.0081, space_type_gen: true, default: false } - hash['StaffLounge'] = { ratio: 0.0081, space_type_gen: true, default: false } - hash['Stair'] = { ratio: 0.0400, space_type_gen: true, default: false } - hash['Storage'] = { ratio: 0.0325, space_type_gen: true, default: false } - else - hash['Corridor'] = { ratio: 0.1313, space_type_gen: true, default: false, circ: true } - hash['Elec/MechRoom'] = { ratio: 0.0038, space_type_gen: true, default: false } - hash['ElevatorCore'] = { ratio: 0.0113, space_type_gen: true, default: false } - hash['Exercise'] = { ratio: 0.0081, space_type_gen: true, default: false } - hash['GuestLounge'] = { ratio: 0.0406, space_type_gen: true, default: false } - hash['GuestRoom123Occ'] = { ratio: 0.4081, space_type_gen: true, default: true } - hash['GuestRoom123Vac'] = { ratio: 0.2231, space_type_gen: true, default: false } - hash['Laundry'] = { ratio: 0.0244, space_type_gen: true, default: false } - hash['Mechanical'] = { ratio: 0.0081, space_type_gen: true, default: false } - hash['Meeting'] = { ratio: 0.0200, space_type_gen: true, default: false } - hash['Office'] = { ratio: 0.0325, space_type_gen: true, default: false } - hash['PublicRestroom'] = { ratio: 0.0081, space_type_gen: true, default: false } - hash['StaffLounge'] = { ratio: 0.0081, space_type_gen: true, default: false } - hash['Stair'] = { ratio: 0.0400, space_type_gen: true, default: false } - hash['Storage'] = { ratio: 0.0325, space_type_gen: true, default: false } - end + hash['Corridor'] = { ratio: 0.1313, space_type_gen: true, default: false, circ: true } + hash['Elec/MechRoom'] = { ratio: 0.0038, space_type_gen: true, default: false } + hash['ElevatorCore'] = { ratio: 0.0113, space_type_gen: true, default: false } + hash['Exercise'] = { ratio: 0.0081, space_type_gen: true, default: false } + hash['GuestLounge'] = { ratio: 0.0406, space_type_gen: true, default: false } + hash['GuestRoom123Occ'] = { ratio: 0.4081, space_type_gen: true, default: true } + hash['GuestRoom123Vac'] = { ratio: 0.2231, space_type_gen: true, default: false } + hash['Laundry'] = { ratio: 0.0244, space_type_gen: true, default: false } + hash['Mechanical'] = { ratio: 0.0081, space_type_gen: true, default: false } + hash['Meeting'] = { ratio: 0.0200, space_type_gen: true, default: false } + hash['Office'] = { ratio: 0.0325, space_type_gen: true, default: false } + hash['PublicRestroom'] = { ratio: 0.0081, space_type_gen: true, default: false } + hash['StaffLounge'] = { ratio: 0.0081, space_type_gen: true, default: false } + hash['Stair'] = { ratio: 0.0400, space_type_gen: true, default: false } + hash['Storage'] = { ratio: 0.0325, space_type_gen: true, default: false } elsif building_type == 'LargeHotel' hash['Banquet'] = { ratio: 0.0585, space_type_gen: true, default: false } hash['Basement'] = { ratio: 0.1744, space_type_gen: false, default: false } @@ -446,11 +429,11 @@ def self.get_space_types_from_building_type(building_type, template, whole_build elsif building_type == 'Rt3' hash['RetailSales'] = { ratio: 1.0, space_type_gen: true, default: true } elsif building_type == 'RtL' - hash['OfficeGeneral'] = { ratio: 0.0359, space_type_gen: true, default: false } - hash['Work'] = { ratio: 0.04, space_type_gen: true, default: false } - hash['StockRoom'] = { ratio: 0.091, space_type_gen: true, default: false } - hash['RetailSales'] = { ratio: 0.8219, space_type_gen: true, default: true } - hash['Kitchen'] = { ratio: 0.0113, space_type_gen: true, default: false } + hash['OfficeGeneral'] = { ratio: 0.0363, space_type_gen: true, default: false } + hash['Work'] = { ratio: 0.0405, space_type_gen: true, default: false } + hash['StockRoom'] = { ratio: 0.0920, space_type_gen: true, default: false } + hash['RetailSales'] = { ratio: 0.8312, space_type_gen: true, default: true } + # hash['Kitchen'] = { ratio: 0.0113, space_type_gen: true, default: false } elsif building_type == 'RtS' hash['RetailSales'] = { ratio: 0.8, space_type_gen: true, default: true } hash['StockRoom'] = { ratio: 0.2, space_type_gen: true, default: false } diff --git a/lib/openstudio-standards/geometry/create.rb b/lib/openstudio-standards/geometry/create.rb index 91a2fcf257..d5cacab39b 100644 --- a/lib/openstudio-standards/geometry/create.rb +++ b/lib/openstudio-standards/geometry/create.rb @@ -422,18 +422,16 @@ def self.create_bar(runner, model, bar_hash, story_multiplier_method = 'Basement spaces_temp = OpenStudio::Model::SpaceVector.new spaces_temp << space_a spaces_temp << space_b - # attempt to intersect and match walls on a story, but later secondary match will look for missted matches and turn them to adiabaitc + # intersect and sort OpenStudio::Model.intersectSurfaces(spaces_temp) OpenStudio::Model.matchSurfaces(spaces_temp) end end - runner.registerInfo("Intersecting and matching surfaces in story #{story.name}, this will create additional geometry. Diagnstoic intersection and matching done a in paris of spaces.") + runner.registerInfo("Intersecting and matching surfaces in story #{story.name}, this will create additional geometry.") end end - else - if !(bar_hash[:make_mid_story_surfaces_adiabatic]) # intersect surfaces # (when bottom floor has many space types and one above doesn't will end up with heavily subdivided floor. Maybe use adiabatic and don't intersect floor/ceilings) @@ -449,7 +447,7 @@ def self.create_bar(runner, model, bar_hash, story_multiplier_method = 'Basement story.spaces.sort.each do |space| story_spaces << space end - # attempt to intersect and match walls on a story, but later secondary match will look for missted matches and turn them to adiabaitc + # intersect and sort OpenStudio::Model.intersectSurfaces(story_spaces) OpenStudio::Model.matchSurfaces(story_spaces) @@ -544,7 +542,6 @@ def self.create_bar(runner, model, bar_hash, story_multiplier_method = 'Basement if missed_match_count > 0 runner.registerInfo("#{missed_match_count} surfaces that were exterior appear to be interior walls and had boundary condition chagned to adiabiatic.") end - end # sort stories (by name for now but need better way) @@ -1802,7 +1799,7 @@ def self.bar_from_space_type_ratios(model, runner, user_arguments, args = nil, b runner.registerValue('ew_wall_area_ip', wall_ew_ip, 'ft^2') # for now using perimeter of ground floor and average story area (building area / num_stories) runner.registerValue('floor_area_to_perim_ratio', model.getBuilding.floorArea / (OsLib_Geometry.calculate_perimeter(model) * num_stories)) - runner.registerValue('bar_width_output', OpenStudio.convert(bars['primary'][:width], 'm', 'ft').get, 'ft') + runner.registerValue('bar_width', OpenStudio.convert(bars['primary'][:width], 'm', 'ft').get, 'ft') if args['party_wall_fraction'] > 0 || args['party_wall_stories_north'] > 0 || args['party_wall_stories_south'] > 0 || args['party_wall_stories_east'] > 0 || args['party_wall_stories_west'] > 0 runner.registerInfo('Target facade area by orientation not validated when party walls are applied') From 84e09330d687da8c25daf4e0ddb0460e53a38ebb Mon Sep 17 00:00:00 2001 From: "Lerond, Jeremy" Date: Wed, 4 Oct 2023 16:04:00 -0700 Subject: [PATCH 43/45] Fix typo. --- .../applications/create_openstudio_standards_json.py | 10 +++++----- data/openstudio_standards_data/query/fetch/space.py | 8 ++++---- 2 files changed, 9 insertions(+), 9 deletions(-) diff --git a/data/openstudio_standards_data/applications/create_openstudio_standards_json.py b/data/openstudio_standards_data/applications/create_openstudio_standards_json.py index a336b8a6a7..5a0ead1f00 100644 --- a/data/openstudio_standards_data/applications/create_openstudio_standards_json.py +++ b/data/openstudio_standards_data/applications/create_openstudio_standards_json.py @@ -101,7 +101,7 @@ def create_openstudio_standards_space_data_json( space_type_name = space_type_infos["space_type_name"] if not space_type_name in space_type_names: space_type_names.append(space_type_name) - lighting_space_type_name = space_type_infos["lighting_space_type_name"] + lighting_space_type_name = space_type_infos["LS.lighting_space_type_name"] space_type_data = {"template": template, "space_type": space_type_name} # Get lighting space type data @@ -131,7 +131,7 @@ def create_openstudio_standards_space_data_json( )[0] space_lpd = float(lighting_records["lighting_power_density"]) - space_lpd_unit = lighting_records["unit"] + space_lpd_unit = lighting_records["lighting_power_density_unit"] if space_lpd_unit.lower() == "w/ft2": space_type_data["lighting_per_area"] = space_lpd space_type_data["lighting_per_height"] = 0.0 @@ -168,7 +168,7 @@ def create_openstudio_standards_space_data_json( # Get equipment space type data electric_equipment_space_type_name = space_type_infos[ - "electric_equipment_space_type_name" + "ES.electric_equipment_space_type_name" ] electric_equipment_space_type_data = fetch_records_from_table_by_key_values( conn, @@ -202,7 +202,7 @@ def create_openstudio_standards_space_data_json( space_type_data[f] = 0.0 natural_gas_equipment_space_type_name = space_type_infos[ - "natural_gas_equipment_space_type_name" + "EGS.natural_gas_equipment_space_type_name" ] natural_gas_equipment_space_type_data = fetch_records_from_table_by_key_values( conn, @@ -236,7 +236,7 @@ def create_openstudio_standards_space_data_json( # Get ventilation and occupancy space type data ventilation_space_type_name = space_type_infos[ - "ventilation_space_type_name" + "VS.ventilation_space_type_name" ] ventilation_space_type_data = fetch_records_from_table_by_key_values( conn, diff --git a/data/openstudio_standards_data/query/fetch/space.py b/data/openstudio_standards_data/query/fetch/space.py index be8ca133c1..b922cd5e4f 100644 --- a/data/openstudio_standards_data/query/fetch/space.py +++ b/data/openstudio_standards_data/query/fetch/space.py @@ -8,14 +8,14 @@ SPACE_DATA_HEADER = [ "space_type_name", - "lighting_space_type_name", - "ventilation_space_type_name", + "LS.lighting_space_type_name", + "VS.ventilation_space_type_name", "level_3_lighting_code_definition_table", "level_3_lighting_code_definition_id", "level_3_ventilation_definition_table", "level_3_ventilation_definition_id", - "electric_equipment_space_type_name", - "natural_gas_equipment_space_type_name", + "ES.electric_equipment_space_type_name", + "EGS.natural_gas_equipment_space_type_name", "schedule_set_name", ] From e84baf87621079fd424dc7f3df89f35459a98faa Mon Sep 17 00:00:00 2001 From: "Lerond, Jeremy" Date: Wed, 4 Oct 2023 22:35:39 -0700 Subject: [PATCH 44/45] Add developer notes. --- .../DEVELOPER_README.md | 54 +++++++++++++++++++ 1 file changed, 54 insertions(+) create mode 100644 data/openstudio_standards_data/DEVELOPER_README.md diff --git a/data/openstudio_standards_data/DEVELOPER_README.md b/data/openstudio_standards_data/DEVELOPER_README.md new file mode 100644 index 0000000000..fb90c89960 --- /dev/null +++ b/data/openstudio_standards_data/DEVELOPER_README.md @@ -0,0 +1,54 @@ +# Notes for Developers +## Prerequisites +Below are listed the prerequisites to any of the database related code. +- Python 3.10 +## Expanding the Database +Developers wishing to expand the database do not need advanced SQL knowledge to do so. The following tips should provide enough information to expand the database. +### Adding Tables and Data for a New Code Versions +#### Creating New Tables +Table definitions are located in `database_tables`. A good starting point is a copy of an existing table definition file that most closely match the content of the table that you wish to add. +* If you are creating a table that inherits from a parent (e.g., `level_3_lighting_90_1_2004.py` which inherits from `level_3_lighting_90_1_definition.py`): + * Rename the `table_name` variable + * Rename the name of the class and subsequent mention of it in that file + + __Example__: Add a level 3 (code requirement) table for lighting power allowances 90.1-1975. One could copy the content of `level_3_lighting_90_1_2004.py` and modify it as follows: + + ``` + import sqlite3 + from database_tables.level_3_lighting_90_1_definition import LightDef901 + TABLE_NAME = "level_3_lighting_90_1_1975" + class LightDef9011975Table(LightDef901): + def __init__(self): + super(LightDef9011975Table, self).__init__( + table_name=TABLE_NAME, + initial_data_directory=f"database_files/{TABLE_NAME}", + ) + ``` + + * If inherited attributes need to be modified, for example a new column needs to be added, the attribute can be overwritten in the new table definition file. Be mindful that it's possible that some attribute depend on others, for example if `record_template` is modified, then `insert_record_query` should be modified as well. +* If you are creating a table that does not inherit from a parent (e.g., support tables): + * Rename the `table_name` variable and all other attributes (`record_template`, `initial_data_directory`, `create_table_query`, `insert_record_query`) + * update the `_preprocess_record` function. +* When modifying `create_table_query` use either `TEXT` or `NUMERIC` when describing a column and use `NOT NULL` when a value in the column cannot be blank. +#### Space Type Data +* Start by adding tables for the lowest level of space type data. For instance, for lighting and ventilation, this is level 3, i.e., the data as represented in the code. +* Map data to the parent level. For instance, for lighting and ventilation this would be level 2. +Note that not all records for the lowest level should be necessarily mapped to a parent level. +#### Define Relationships +Relationship between column (or keys) from a table to another is established in the `create_table_query` attribute. In the example below the column (or key) `lighting_space_type_name` from a table that's being created is in relation with the `lighting_space_type_name` column (or key) from the `support_lighting_space_type_name_tags` table. +``` +FOREIGN KEY(lighting_space_type_name) REFERENCES support_lighting_space_type_name_tags(lighting_space_type_name) +``` +#### Adding Data +Data can be provided either in CSV or in the JSON file format. The best approach is to: +1) Generate the database, +2) Export the content to CSV or JSON, +3) Modify the database structure (see the Creating New Tables section above), +4) Add a new CSV of JSON file in the data folder corresponding to the `initial_data_directory` attribute in the new table class, +5) Re-generate the database. +#### Tests +A small set of tests have been implemented, mostly to make sure that further edits to the data or database structure is valid, and that JSON and CSV files generated from the database include the same content. After modifying the database, it is good practice to run the tests locally to verify the integrity of the database. From the root directory one can run the following command: +``` +pytest test +``` +An error will be displayed if the tests failed. \ No newline at end of file From c09d24b3bfac2d818d43312f8148b8cf1202f111 Mon Sep 17 00:00:00 2001 From: "Lerond, Jeremy" Date: Mon, 9 Oct 2023 15:02:29 -0700 Subject: [PATCH 45/45] Fix IDS. --- .../level_3_lighting_90_1_2004.json | 476 +++---- .../level_3_lighting_90_1_2007.json | 522 ++++---- .../level_3_lighting_90_1_2010.json | 764 ++++++------ .../level_3_lighting_90_1_2013.json | 1098 ++++++++--------- .../level_3_lighting_90_1_2016.json | 1086 ++++++++-------- .../level_3_lighting_90_1_2019.json | 364 +++--- 6 files changed, 2155 insertions(+), 2155 deletions(-) diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2004.json b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2004.json index 6edfe37c24..fbb86d2a2d 100644 --- a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2004.json +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2004.json @@ -449,9 +449,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Office-Enclosed", - "lighting_secondary_space_type": "General", - "lighting_power_density": 1.1, + "lighting_primary_space_type": "Active Storage", + "lighting_secondary_space_type": "For Hospital", + "lighting_power_density": 0.9, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -463,9 +463,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Office-Open Plan", + "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "General", - "lighting_power_density": 1.1, + "lighting_power_density": 0.8, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -477,51 +477,51 @@ }, { "method": "CS", - "lighting_primary_space_type": "Conference/Meeting/Multipurpose", + "lighting_primary_space_type": "Atrium: Each Additional Floor", "lighting_secondary_space_type": "General", - "lighting_power_density": 1.3, + "lighting_power_density": 0.2, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, "automatic_partial_off": null, - "automatic_full_off": "REQ", + "automatic_full_off": null, "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Classroom/Lecture/Training", + "lighting_primary_space_type": "Atrium: First Three Floors", "lighting_secondary_space_type": "General", - "lighting_power_density": 1.4, + "lighting_power_density": 0.6, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, "automatic_partial_off": null, - "automatic_full_off": "REQ", + "automatic_full_off": null, "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Classroom/Lecture/Training", - "lighting_secondary_space_type": "For Penitentiary", - "lighting_power_density": 1.3, + "lighting_primary_space_type": "Audience/Seating Area", + "lighting_secondary_space_type": "For Convention Center", + "lighting_power_density": 0.7, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, "automatic_partial_off": null, - "automatic_full_off": "REQ", + "automatic_full_off": null, "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "General", - "lighting_power_density": 1.3, + "lighting_primary_space_type": "Audience/Seating Area", + "lighting_secondary_space_type": "For Exercise Center", + "lighting_power_density": 0.3, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -533,9 +533,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "For Hotel", - "lighting_power_density": 1.1, + "lighting_primary_space_type": "Audience/Seating Area", + "lighting_secondary_space_type": "For Gymnasium", + "lighting_power_density": 0.4, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -547,9 +547,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "For Performing Arts Theater", - "lighting_power_density": 3.3, + "lighting_primary_space_type": "Audience/Seating Area", + "lighting_secondary_space_type": "For Motion Picture Theater", + "lighting_power_density": 1.2, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -561,9 +561,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "For Motion Picture Theater", - "lighting_power_density": 1.1, + "lighting_primary_space_type": "Audience/Seating Area", + "lighting_secondary_space_type": "For Penitentiary", + "lighting_power_density": 0.7, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -576,8 +576,8 @@ { "method": "CS", "lighting_primary_space_type": "Audience/Seating Area", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.9, + "lighting_secondary_space_type": "For Performing Arts Theater", + "lighting_power_density": 2.6, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -590,8 +590,8 @@ { "method": "CS", "lighting_primary_space_type": "Audience/Seating Area", - "lighting_secondary_space_type": "For Gymnasium", - "lighting_power_density": 0.4, + "lighting_secondary_space_type": "For Religious Buildings", + "lighting_power_density": 1.7, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -604,8 +604,8 @@ { "method": "CS", "lighting_primary_space_type": "Audience/Seating Area", - "lighting_secondary_space_type": "For Exercise Center", - "lighting_power_density": 0.3, + "lighting_secondary_space_type": "For Sports Arena", + "lighting_power_density": 0.4, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -618,8 +618,8 @@ { "method": "CS", "lighting_primary_space_type": "Audience/Seating Area", - "lighting_secondary_space_type": "For Convention Center", - "lighting_power_density": 0.7, + "lighting_secondary_space_type": "For Transportation", + "lighting_power_density": 0.5, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -632,8 +632,8 @@ { "method": "CS", "lighting_primary_space_type": "Audience/Seating Area", - "lighting_secondary_space_type": "For Penitentiary", - "lighting_power_density": 0.7, + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.9, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -645,51 +645,51 @@ }, { "method": "CS", - "lighting_primary_space_type": "Audience/Seating Area", - "lighting_secondary_space_type": "For Religious Buildings", - "lighting_power_density": 1.7, + "lighting_primary_space_type": "Classroom/Lecture/Training", + "lighting_secondary_space_type": "For Penitentiary", + "lighting_power_density": 1.3, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, "automatic_partial_off": null, - "automatic_full_off": null, + "automatic_full_off": "REQ", "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Audience/Seating Area", - "lighting_secondary_space_type": "For Sports Arena", - "lighting_power_density": 0.4, + "lighting_primary_space_type": "Classroom/Lecture/Training", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.4, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, "automatic_partial_off": null, - "automatic_full_off": null, + "automatic_full_off": "REQ", "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Audience/Seating Area", - "lighting_secondary_space_type": "For Performing Arts Theater", - "lighting_power_density": 2.6, + "lighting_primary_space_type": "Conference/Meeting/Multipurpose", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.3, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, "automatic_partial_off": null, - "automatic_full_off": null, + "automatic_full_off": "REQ", "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Audience/Seating Area", - "lighting_secondary_space_type": "For Motion Picture Theater", - "lighting_power_density": 1.2, + "lighting_primary_space_type": "Corridor/Transition", + "lighting_secondary_space_type": "For Hospital", + "lighting_power_density": 1, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -701,8 +701,8 @@ }, { "method": "CS", - "lighting_primary_space_type": "Audience/Seating Area", - "lighting_secondary_space_type": "For Transportation", + "lighting_primary_space_type": "Corridor/Transition", + "lighting_secondary_space_type": "For Manufacturing Facility", "lighting_power_density": 0.5, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, @@ -715,9 +715,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Atrium: First Three Floors", + "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", - "lighting_power_density": 0.6, + "lighting_power_density": 0.5, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -729,9 +729,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Atrium: Each Additional Floor", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.2, + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "For Bar Lounge/Leisure Dining", + "lighting_power_density": 1.4, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -743,37 +743,37 @@ }, { "method": "CS", - "lighting_primary_space_type": "Lounge/Recreation", - "lighting_secondary_space_type": "General", - "lighting_power_density": 1.2, + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "For Family Dining", + "lighting_power_density": 2.1, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, "automatic_partial_off": null, - "automatic_full_off": "REQ", + "automatic_full_off": null, "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Lounge/Recreation", - "lighting_secondary_space_type": "For Hospital", - "lighting_power_density": 0.8, + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "For Hotel", + "lighting_power_density": 1.3, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, "automatic_partial_off": null, - "automatic_full_off": "REQ", + "automatic_full_off": null, "scheduled_shutoff": null, "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.9, + "lighting_secondary_space_type": "For Motel", + "lighting_power_density": 1.2, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -800,8 +800,8 @@ { "method": "CS", "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "For Hotel", - "lighting_power_density": 1.3, + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.9, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -813,9 +813,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "For Motel", - "lighting_power_density": 1.2, + "lighting_primary_space_type": "Dressing/Locker/Fitting Room", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.6, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -827,9 +827,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "For Bar Lounge/Leisure Dining", - "lighting_power_density": 1.4, + "lighting_primary_space_type": "Electrical/Mechanical", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.5, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -841,9 +841,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "For Family Dining", - "lighting_power_density": 2.1, + "lighting_primary_space_type": "Food Preparation", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.2, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -855,9 +855,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Food Preparation", - "lighting_secondary_space_type": "General", - "lighting_power_density": 1.2, + "lighting_primary_space_type": "Inactive Storage", + "lighting_secondary_space_type": "For Museum", + "lighting_power_density": 0.8, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -869,9 +869,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Laboratory", + "lighting_primary_space_type": "Inactive Storage", "lighting_secondary_space_type": "General", - "lighting_power_density": 1.4, + "lighting_power_density": 0.3, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -883,9 +883,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Restrooms", + "lighting_primary_space_type": "Laboratory", "lighting_secondary_space_type": "General", - "lighting_power_density": 0.9, + "lighting_power_density": 1.4, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -897,9 +897,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Dressing/Locker/Fitting Room", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.6, + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "For Hotel", + "lighting_power_density": 1.1, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -911,9 +911,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Corridor/Transition", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.5, + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "For Motion Picture Theater", + "lighting_power_density": 1.1, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -925,9 +925,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Corridor/Transition", - "lighting_secondary_space_type": "For Hospital", - "lighting_power_density": 1, + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "For Performing Arts Theater", + "lighting_power_density": 3.3, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -939,9 +939,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Corridor/Transition", - "lighting_secondary_space_type": "For Manufacturing Facility", - "lighting_power_density": 0.5, + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.3, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -953,37 +953,37 @@ }, { "method": "CS", - "lighting_primary_space_type": "Stairs: Active", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.6, + "lighting_primary_space_type": "Lounge/Recreation", + "lighting_secondary_space_type": "For Hospital", + "lighting_power_density": 0.8, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, "automatic_partial_off": null, - "automatic_full_off": null, + "automatic_full_off": "REQ", "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Active Storage", + "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "General", - "lighting_power_density": 0.8, + "lighting_power_density": 1.2, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, "automatic_partial_off": null, - "automatic_full_off": null, + "automatic_full_off": "REQ", "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Active Storage", - "lighting_secondary_space_type": "For Hospital", - "lighting_power_density": 0.9, + "lighting_primary_space_type": "Office-Enclosed", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.1, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -995,9 +995,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Inactive Storage", + "lighting_primary_space_type": "Office-Open Plan", "lighting_secondary_space_type": "General", - "lighting_power_density": 0.3, + "lighting_power_density": 1.1, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1009,9 +1009,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Inactive Storage", - "lighting_secondary_space_type": "For Museum", - "lighting_power_density": 0.8, + "lighting_primary_space_type": "Restrooms", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.9, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1023,9 +1023,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Electrical/Mechanical", + "lighting_primary_space_type": "Stairs: Active", "lighting_secondary_space_type": "General", - "lighting_power_density": 1.5, + "lighting_power_density": 0.6, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1051,9 +1051,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Gymnasium/Exercise Center", - "lighting_secondary_space_type": "Playing Area", - "lighting_power_density": 1.4, + "lighting_primary_space_type": "Automotive: Service/Repair", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.7, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1065,9 +1065,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Gymnasium/Exercise Center", - "lighting_secondary_space_type": "Exercise Area", - "lighting_power_density": 0.9, + "lighting_primary_space_type": "Bank/Office Banking Activity Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.5, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1079,9 +1079,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", - "lighting_secondary_space_type": "Courtroom", - "lighting_power_density": 1.9, + "lighting_primary_space_type": "Convention Center: Exhibit Space", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.3, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1105,6 +1105,20 @@ "scheduled_shutoff": null, "annotation": null }, + { + "method": "SS", + "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", + "lighting_secondary_space_type": "Courtroom", + "lighting_power_density": 1.9, + "lighting_power_density_unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, { "method": "SS", "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", @@ -1121,9 +1135,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Fire Stations", - "lighting_secondary_space_type": "Fire Station Engine Room", - "lighting_power_density": 0.8, + "lighting_primary_space_type": "Dormitory: Living Quarters", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.1, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1136,8 +1150,8 @@ { "method": "SS", "lighting_primary_space_type": "Fire Stations", - "lighting_secondary_space_type": "Sleeping Quarters", - "lighting_power_density": 0.3, + "lighting_secondary_space_type": "Fire Station Engine Room", + "lighting_power_density": 0.8, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1149,9 +1163,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Post Office: Sorting Area", - "lighting_secondary_space_type": "General", - "lighting_power_density": 1.2, + "lighting_primary_space_type": "Fire Stations", + "lighting_secondary_space_type": "Sleeping Quarters", + "lighting_power_density": 0.3, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1163,9 +1177,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Convention Center: Exhibit Space", - "lighting_secondary_space_type": "General", - "lighting_power_density": 1.3, + "lighting_primary_space_type": "Gymnasium/Exercise Center", + "lighting_secondary_space_type": "Exercise Area", + "lighting_power_density": 0.9, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1177,9 +1191,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Library", - "lighting_secondary_space_type": "Card File and Cataloging", - "lighting_power_density": 1.1, + "lighting_primary_space_type": "Gymnasium/Exercise Center", + "lighting_secondary_space_type": "Playing Area", + "lighting_power_density": 1.4, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1191,9 +1205,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Library", - "lighting_secondary_space_type": "Stacks", - "lighting_power_density": 1.7, + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Emergency", + "lighting_power_density": 2.7, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1205,9 +1219,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Library", - "lighting_secondary_space_type": "Reading Area", - "lighting_power_density": 1.2, + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Exam/Treatment", + "lighting_power_density": 1.5, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1220,8 +1234,8 @@ { "method": "SS", "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Emergency", - "lighting_power_density": 2.7, + "lighting_secondary_space_type": "Laundry: Washing", + "lighting_power_density": 0.6, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1234,8 +1248,8 @@ { "method": "SS", "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Recovery", - "lighting_power_density": 0.8, + "lighting_secondary_space_type": "Medical Supply", + "lighting_power_density": 1.4, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1262,8 +1276,8 @@ { "method": "SS", "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Exam/Treatment", - "lighting_power_density": 1.5, + "lighting_secondary_space_type": "Nursery", + "lighting_power_density": 0.6, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1276,8 +1290,8 @@ { "method": "SS", "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Pharmacy", - "lighting_power_density": 1.2, + "lighting_secondary_space_type": "Operating Room", + "lighting_power_density": 2.2, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1304,8 +1318,8 @@ { "method": "SS", "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Operating Room", - "lighting_power_density": 2.2, + "lighting_secondary_space_type": "Pharmacy", + "lighting_power_density": 1.2, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1318,8 +1332,8 @@ { "method": "SS", "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Nursery", - "lighting_power_density": 0.6, + "lighting_secondary_space_type": "Physical Therapy", + "lighting_power_density": 0.9, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1332,8 +1346,8 @@ { "method": "SS", "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Medical Supply", - "lighting_power_density": 1.4, + "lighting_secondary_space_type": "Radiology", + "lighting_power_density": 0.4, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1346,8 +1360,8 @@ { "method": "SS", "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Physical Therapy", - "lighting_power_density": 0.9, + "lighting_secondary_space_type": "Recovery", + "lighting_power_density": 0.8, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1359,9 +1373,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Radiology", - "lighting_power_density": 0.4, + "lighting_primary_space_type": "Hotel/Motel Guest Rooms", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.1, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1373,9 +1387,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Laundry: Washing", - "lighting_power_density": 0.6, + "lighting_primary_space_type": "Library", + "lighting_secondary_space_type": "Card File and Cataloging", + "lighting_power_density": 1.1, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1387,9 +1401,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Automotive: Service/Repair", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.7, + "lighting_primary_space_type": "Library", + "lighting_secondary_space_type": "Reading Area", + "lighting_power_density": 1.2, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1401,9 +1415,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Manufacturing", - "lighting_secondary_space_type": "Low Bay (<25 ft Floor to Ceiling Height)", - "lighting_power_density": 1.2, + "lighting_primary_space_type": "Library", + "lighting_secondary_space_type": "Stacks", + "lighting_power_density": 1.7, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1416,8 +1430,8 @@ { "method": "SS", "lighting_primary_space_type": "Manufacturing", - "lighting_secondary_space_type": "High Bay (>25 ft Floor to Ceiling Height)", - "lighting_power_density": 1.7, + "lighting_secondary_space_type": "Control Room", + "lighting_power_density": 0.5, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1458,8 +1472,8 @@ { "method": "SS", "lighting_primary_space_type": "Manufacturing", - "lighting_secondary_space_type": "Control Room", - "lighting_power_density": 0.5, + "lighting_secondary_space_type": "High Bay (>25 ft Floor to Ceiling Height)", + "lighting_power_density": 1.7, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1471,9 +1485,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Hotel/Motel Guest Rooms", - "lighting_secondary_space_type": "General", - "lighting_power_density": 1.1, + "lighting_primary_space_type": "Manufacturing", + "lighting_secondary_space_type": "Low Bay (<25 ft Floor to Ceiling Height)", + "lighting_power_density": 1.2, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1485,9 +1499,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Dormitory: Living Quarters", - "lighting_secondary_space_type": "General", - "lighting_power_density": 1.1, + "lighting_primary_space_type": "Museum", + "lighting_secondary_space_type": "General Exhibition", + "lighting_power_density": 1, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1500,8 +1514,8 @@ { "method": "SS", "lighting_primary_space_type": "Museum", - "lighting_secondary_space_type": "General Exhibition", - "lighting_power_density": 1, + "lighting_secondary_space_type": "Restoration", + "lighting_power_density": 1.7, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1513,9 +1527,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Museum", - "lighting_secondary_space_type": "Restoration", - "lighting_power_density": 1.7, + "lighting_primary_space_type": "None", + "lighting_secondary_space_type": "None", + "lighting_power_density": 0, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1527,9 +1541,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Bank/Office Banking Activity Area", + "lighting_primary_space_type": "Parking Garage: Garage Area", "lighting_secondary_space_type": "General", - "lighting_power_density": 1.5, + "lighting_power_density": 0.2, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1541,9 +1555,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Religious Buildings", - "lighting_secondary_space_type": "Worship Pulpit, Choir", - "lighting_power_density": 2.4, + "lighting_primary_space_type": "Post Office: Sorting Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.2, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1569,9 +1583,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Sales Area", - "lighting_power_density": 1.7, + "lighting_primary_space_type": "Religious Buildings", + "lighting_secondary_space_type": "Worship Pulpit, Choir", + "lighting_power_density": 2.4, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1597,9 +1611,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Sports Arena", - "lighting_secondary_space_type": "Ring Sports Area", - "lighting_power_density": 2.7, + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (Specific Display)", + "lighting_power_density": 1.6, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1611,9 +1625,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Sports Arena", - "lighting_secondary_space_type": "Court Sports Area", - "lighting_power_density": 2.3, + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (Valuable Merchandise)", + "lighting_power_density": 3.9, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1625,9 +1639,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Sports Arena", - "lighting_secondary_space_type": "Indoor Playing Field Area", - "lighting_power_density": 1.4, + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Area", + "lighting_power_density": 1.7, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1639,9 +1653,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Warehouse", - "lighting_secondary_space_type": "Fine Material Storage", - "lighting_power_density": 1.4, + "lighting_primary_space_type": "Sports Arena", + "lighting_secondary_space_type": "Court Sports Area", + "lighting_power_density": 2.3, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1653,9 +1667,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Warehouse", - "lighting_secondary_space_type": "Medium/Bulky Material Storage", - "lighting_power_density": 0.9, + "lighting_primary_space_type": "Sports Arena", + "lighting_secondary_space_type": "Indoor Playing Field Area", + "lighting_power_density": 1.4, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1667,9 +1681,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Parking Garage: Garage Area", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.2, + "lighting_primary_space_type": "Sports Arena", + "lighting_secondary_space_type": "Ring Sports Area", + "lighting_power_density": 2.7, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1682,8 +1696,8 @@ { "method": "SS", "lighting_primary_space_type": "Transportation", - "lighting_secondary_space_type": "Airport: Concourse", - "lighting_power_density": 0.6, + "lighting_secondary_space_type": "Air/Train/Bus: Baggage Area", + "lighting_power_density": 1, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1696,8 +1710,8 @@ { "method": "SS", "lighting_primary_space_type": "Transportation", - "lighting_secondary_space_type": "Air/Train/Bus: Baggage Area", - "lighting_power_density": 1, + "lighting_secondary_space_type": "Airport: Concourse", + "lighting_power_density": 0.6, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1723,23 +1737,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Sales Additional (Specific Display)", - "lighting_power_density": 1.6, - "lighting_power_density_unit": "W/ft2", - "rcr_threshold": null, - "automatic_daylight_responsive_controls_for_sidelighting": null, - "automatic_daylight_responsive_controls_for_toplighting": null, - "automatic_partial_off": null, - "automatic_full_off": null, - "scheduled_shutoff": null, - "annotation": null - }, - { - "method": "SS", - "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Sales Additional (Valuable Merchandise)", - "lighting_power_density": 3.9, + "lighting_primary_space_type": "Warehouse", + "lighting_secondary_space_type": "Fine Material Storage", + "lighting_power_density": 1.4, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1751,9 +1751,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "None", - "lighting_secondary_space_type": "None", - "lighting_power_density": 0, + "lighting_primary_space_type": "Warehouse", + "lighting_secondary_space_type": "Medium/Bulky Material Storage", + "lighting_power_density": 0.9, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2007.json b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2007.json index 49ca9bb4a7..5bc9f34c63 100644 --- a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2007.json +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2007.json @@ -449,9 +449,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "For Bar Lounge/Leisure Dining", - "lighting_power_density": 1.4, + "lighting_primary_space_type": "Active Storage", + "lighting_secondary_space_type": "For Hospital", + "lighting_power_density": 0.9, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -463,9 +463,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Audience/seating Area", - "lighting_secondary_space_type": "For Convention Center", - "lighting_power_density": 0.7, + "lighting_primary_space_type": "Active Storage", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.8, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -477,9 +477,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "For Family Dining", - "lighting_power_density": 2.1, + "lighting_primary_space_type": "Atrium each Additional Floor", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.2, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -491,9 +491,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Audience/seating Area", - "lighting_secondary_space_type": "For Exercise Center", - "lighting_power_density": 0.3, + "lighting_primary_space_type": "Atrium first Three Floors", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.6, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -505,9 +505,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Active Storage", - "lighting_secondary_space_type": "For Hospital", - "lighting_power_density": 0.9, + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "For Convention Center", + "lighting_power_density": 0.7, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -519,9 +519,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Corridor/transition", - "lighting_secondary_space_type": "For Hospital", - "lighting_power_density": 1, + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "For Exercise Center", + "lighting_power_density": 0.3, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -533,23 +533,23 @@ }, { "method": "CS", - "lighting_primary_space_type": "Lounge/Recreation", - "lighting_secondary_space_type": "For Hospital", - "lighting_power_density": 0.8, + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "For Gymnasium", + "lighting_power_density": 0.4, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, "automatic_partial_off": null, - "automatic_full_off": "REQ", + "automatic_full_off": null, "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "For Hotel", - "lighting_power_density": 1.3, + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "For Motion Picture Theater", + "lighting_power_density": 1.2, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -561,9 +561,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "For Hotel", - "lighting_power_density": 1.1, + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "For Penitentiary", + "lighting_power_density": 0.7, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -575,9 +575,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Corridor/transition", - "lighting_secondary_space_type": "For Manufacturing Facility", - "lighting_power_density": 0.5, + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "For Performing Arts Theater", + "lighting_power_density": 2.6, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -589,9 +589,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "For Motel", - "lighting_power_density": 1.2, + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "For Religious Buildings", + "lighting_power_density": 1.7, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -604,8 +604,8 @@ { "method": "CS", "lighting_primary_space_type": "Audience/seating Area", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.9, + "lighting_secondary_space_type": "For Sports Arena", + "lighting_power_density": 0.4, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -617,9 +617,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "For Motion Picture Theater", - "lighting_power_density": 1.1, + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "For Transportation", + "lighting_power_density": 0.5, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -631,9 +631,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Inactive Storage", - "lighting_secondary_space_type": "For Museum", - "lighting_power_density": 0.8, + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.9, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -659,37 +659,37 @@ }, { "method": "CS", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "For Penitentiary", - "lighting_power_density": 1.3, + "lighting_primary_space_type": "Classroom/Lecture/Training", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.4, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, "automatic_partial_off": null, - "automatic_full_off": null, + "automatic_full_off": "REQ", "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Audience/seating Area", - "lighting_secondary_space_type": "For Gymnasium", - "lighting_power_density": 0.4, + "lighting_primary_space_type": "Conference/Meeting/Multipurpose", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.3, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, "automatic_partial_off": null, - "automatic_full_off": null, + "automatic_full_off": "REQ", "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "For Performing Arts Theater", - "lighting_power_density": 3.3, + "lighting_primary_space_type": "Corridor/transition", + "lighting_secondary_space_type": "For Hospital", + "lighting_power_density": 1, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -701,9 +701,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Audience/seating Area", - "lighting_secondary_space_type": "For Motion Picture Theater", - "lighting_power_density": 1.2, + "lighting_primary_space_type": "Corridor/transition", + "lighting_secondary_space_type": "For Manufacturing Facility", + "lighting_power_density": 0.5, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -715,9 +715,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Active Storage", + "lighting_primary_space_type": "Corridor/transition", "lighting_secondary_space_type": "General", - "lighting_power_density": 0.8, + "lighting_power_density": 0.5, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -729,9 +729,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Atrium each Additional Floor", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.2, + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "For Bar Lounge/Leisure Dining", + "lighting_power_density": 1.4, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -743,9 +743,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Atrium first Three Floors", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.6, + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "For Family Dining", + "lighting_power_density": 2.1, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -757,37 +757,37 @@ }, { "method": "CS", - "lighting_primary_space_type": "Classroom/Lecture/Training", - "lighting_secondary_space_type": "General", - "lighting_power_density": 1.4, + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "For Hotel", + "lighting_power_density": 1.3, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, "automatic_partial_off": null, - "automatic_full_off": "REQ", + "automatic_full_off": null, "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Conference/Meeting/Multipurpose", - "lighting_secondary_space_type": "General", - "lighting_power_density": 1.3, + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "For Motel", + "lighting_power_density": 1.2, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, "automatic_partial_off": null, - "automatic_full_off": "REQ", + "automatic_full_off": null, "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Corridor/transition", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.5, + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "For Penitentiary", + "lighting_power_density": 1.3, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -856,8 +856,8 @@ { "method": "CS", "lighting_primary_space_type": "Inactive Storage", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.3, + "lighting_secondary_space_type": "For Museum", + "lighting_power_density": 0.8, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -869,9 +869,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Laboratory", + "lighting_primary_space_type": "Inactive Storage", "lighting_secondary_space_type": "General", - "lighting_power_density": 1.4, + "lighting_power_density": 0.3, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -883,9 +883,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Lobby", + "lighting_primary_space_type": "Laboratory", "lighting_secondary_space_type": "General", - "lighting_power_density": 1.3, + "lighting_power_density": 1.4, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -897,22 +897,22 @@ }, { "method": "CS", - "lighting_primary_space_type": "Lounge/Recreation", - "lighting_secondary_space_type": "General", - "lighting_power_density": 1.2, + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "For Hotel", + "lighting_power_density": 1.1, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, "automatic_partial_off": null, - "automatic_full_off": "REQ", + "automatic_full_off": null, "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Office-Enclosed", - "lighting_secondary_space_type": "General", + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "For Motion Picture Theater", "lighting_power_density": 1.1, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, @@ -925,9 +925,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Office-Open Plan", - "lighting_secondary_space_type": "General", - "lighting_power_density": 1.1, + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "For Performing Arts Theater", + "lighting_power_density": 3.3, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -939,9 +939,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Restrooms", + "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", - "lighting_power_density": 0.9, + "lighting_power_density": 1.3, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -953,37 +953,37 @@ }, { "method": "CS", - "lighting_primary_space_type": "Sales Area", - "lighting_secondary_space_type": "General", - "lighting_power_density": 1.7, + "lighting_primary_space_type": "Lounge/Recreation", + "lighting_secondary_space_type": "For Hospital", + "lighting_power_density": 0.8, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, "automatic_partial_off": null, - "automatic_full_off": null, + "automatic_full_off": "REQ", "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Audience/seating Area", - "lighting_secondary_space_type": "For Penitentiary", - "lighting_power_density": 0.7, + "lighting_primary_space_type": "Lounge/Recreation", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.2, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": null, "automatic_partial_off": null, - "automatic_full_off": null, + "automatic_full_off": "REQ", "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Stairs active", + "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", - "lighting_power_density": 0.6, + "lighting_power_density": 1.1, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -995,9 +995,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Workshop", + "lighting_primary_space_type": "Office-Open Plan", "lighting_secondary_space_type": "General", - "lighting_power_density": 1.9, + "lighting_power_density": 1.1, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1009,9 +1009,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Audience/seating Area", - "lighting_secondary_space_type": "For Performing Arts Theater", - "lighting_power_density": 2.6, + "lighting_primary_space_type": "Restrooms", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.9, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1023,8 +1023,8 @@ }, { "method": "CS", - "lighting_primary_space_type": "Audience/seating Area", - "lighting_secondary_space_type": "For Religious Buildings", + "lighting_primary_space_type": "Sales Area", + "lighting_secondary_space_type": "General", "lighting_power_density": 1.7, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, @@ -1037,9 +1037,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Audience/seating Area", - "lighting_secondary_space_type": "For Sports Arena", - "lighting_power_density": 0.4, + "lighting_primary_space_type": "Stairs active", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.6, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1051,9 +1051,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Audience/seating Area", - "lighting_secondary_space_type": "For Transportation", - "lighting_power_density": 0.5, + "lighting_primary_space_type": "Workshop", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.9, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1065,9 +1065,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Transportation", - "lighting_secondary_space_type": "Air/Train/Bus Baggage Area", - "lighting_power_density": 1, + "lighting_primary_space_type": "Automotive service/repair", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.7, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1079,9 +1079,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Transportation", - "lighting_secondary_space_type": "Airport Concourse", - "lighting_power_density": 0.6, + "lighting_primary_space_type": "Bank/Office Banking Activity Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.5, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1093,9 +1093,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Library", - "lighting_secondary_space_type": "Card File and Cataloging", - "lighting_power_density": 1.1, + "lighting_primary_space_type": "Convention Center exhibit Space", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.3, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1121,9 +1121,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Manufacturing", - "lighting_secondary_space_type": "Control Room", - "lighting_power_density": 0.5, + "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", + "lighting_secondary_space_type": "Courtroom", + "lighting_power_density": 1.9, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1135,9 +1135,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Sports Arena", - "lighting_secondary_space_type": "Court Sports Area", - "lighting_power_density": 2.3, + "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", + "lighting_secondary_space_type": "Judges Chambers", + "lighting_power_density": 1.3, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1149,9 +1149,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", - "lighting_secondary_space_type": "Courtroom", - "lighting_power_density": 1.9, + "lighting_primary_space_type": "Dormitory living Quarters", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.1, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1163,9 +1163,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Manufacturing", - "lighting_secondary_space_type": "Detailed Manufacturing", - "lighting_power_density": 2.1, + "lighting_primary_space_type": "Fire Stations", + "lighting_secondary_space_type": "Engine Room", + "lighting_power_density": 0.8, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1177,9 +1177,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Emergency", - "lighting_power_density": 2.7, + "lighting_primary_space_type": "Fire Stations", + "lighting_secondary_space_type": "Sleeping Quarters", + "lighting_power_density": 0.3, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1191,9 +1191,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Fire Stations", - "lighting_secondary_space_type": "Engine Room", - "lighting_power_density": 0.8, + "lighting_primary_space_type": "Gymnasium/exercise Center", + "lighting_secondary_space_type": "Exercise Area", + "lighting_power_density": 0.9, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1205,9 +1205,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Manufacturing", - "lighting_secondary_space_type": "Equipment Room", - "lighting_power_density": 1.2, + "lighting_primary_space_type": "Gymnasium/exercise Center", + "lighting_secondary_space_type": "Playing Area", + "lighting_power_density": 1.4, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1220,8 +1220,8 @@ { "method": "SS", "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Exam/Treatment", - "lighting_power_density": 1.5, + "lighting_secondary_space_type": "Emergency", + "lighting_power_density": 2.7, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1233,9 +1233,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Gymnasium/exercise Center", - "lighting_secondary_space_type": "Exercise Area", - "lighting_power_density": 0.9, + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Exam/Treatment", + "lighting_power_density": 1.5, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1247,9 +1247,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Religious Buildings", - "lighting_secondary_space_type": "Fellowship Hall", - "lighting_power_density": 0.9, + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Laundry Washing", + "lighting_power_density": 0.6, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1261,8 +1261,8 @@ }, { "method": "SS", - "lighting_primary_space_type": "Warehouse", - "lighting_secondary_space_type": "Fine Material Storage", + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Medical Supply", "lighting_power_density": 1.4, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, @@ -1275,9 +1275,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Automotive service/repair", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.7, + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Nurse Station", + "lighting_power_density": 1, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1289,9 +1289,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Bank/Office Banking Activity Area", - "lighting_secondary_space_type": "General", - "lighting_power_density": 1.5, + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Nursery", + "lighting_power_density": 0.6, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1303,9 +1303,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Convention Center exhibit Space", - "lighting_secondary_space_type": "General", - "lighting_power_density": 1.3, + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Operating Room", + "lighting_power_density": 2.2, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1317,9 +1317,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Dormitory living Quarters", - "lighting_secondary_space_type": "General", - "lighting_power_density": 1.1, + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Patient Room", + "lighting_power_density": 0.7, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1331,9 +1331,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Hotel/motel Guest Rooms", - "lighting_secondary_space_type": "General", - "lighting_power_density": 1.1, + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Pharmacy", + "lighting_power_density": 1.2, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1345,9 +1345,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Parking Garage garage Area", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.2, + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Physical Therapy", + "lighting_power_density": 0.9, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1359,9 +1359,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Post Office sorting Area", - "lighting_secondary_space_type": "General", - "lighting_power_density": 1.2, + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Radiology", + "lighting_power_density": 0.4, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1373,9 +1373,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Museum", - "lighting_secondary_space_type": "General Exhibition", - "lighting_power_density": 1, + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Recovery", + "lighting_power_density": 0.8, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1387,9 +1387,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Manufacturing", - "lighting_secondary_space_type": "High Bay (>25 ft Floor to Ceiling Height)", - "lighting_power_density": 1.7, + "lighting_primary_space_type": "Hotel/motel Guest Rooms", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.1, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1401,9 +1401,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Sports Arena", - "lighting_secondary_space_type": "Indoor Playing Field Area", - "lighting_power_density": 1.4, + "lighting_primary_space_type": "Library", + "lighting_secondary_space_type": "Card File and Cataloging", + "lighting_power_density": 1.1, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1415,9 +1415,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", - "lighting_secondary_space_type": "Judges Chambers", - "lighting_power_density": 1.3, + "lighting_primary_space_type": "Library", + "lighting_secondary_space_type": "Reading Area", + "lighting_power_density": 1.2, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1429,9 +1429,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Laundry Washing", - "lighting_power_density": 0.6, + "lighting_primary_space_type": "Library", + "lighting_secondary_space_type": "Stacks", + "lighting_power_density": 1.7, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1444,8 +1444,8 @@ { "method": "SS", "lighting_primary_space_type": "Manufacturing", - "lighting_secondary_space_type": "Low Bay (<25 ft Floor to Ceiling Height)", - "lighting_power_density": 1.2, + "lighting_secondary_space_type": "Control Room", + "lighting_power_density": 0.5, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1457,9 +1457,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Mall Concourse", - "lighting_power_density": 1.7, + "lighting_primary_space_type": "Manufacturing", + "lighting_secondary_space_type": "Detailed Manufacturing", + "lighting_power_density": 2.1, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1471,9 +1471,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Medical Supply", - "lighting_power_density": 1.4, + "lighting_primary_space_type": "Manufacturing", + "lighting_secondary_space_type": "Equipment Room", + "lighting_power_density": 1.2, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1485,9 +1485,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Warehouse", - "lighting_secondary_space_type": "Medium/Bulky Material Storage", - "lighting_power_density": 0.9, + "lighting_primary_space_type": "Manufacturing", + "lighting_secondary_space_type": "High Bay (>25 ft Floor to Ceiling Height)", + "lighting_power_density": 1.7, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1499,9 +1499,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Nurse Station", - "lighting_power_density": 1, + "lighting_primary_space_type": "Manufacturing", + "lighting_secondary_space_type": "Low Bay (<25 ft Floor to Ceiling Height)", + "lighting_power_density": 1.2, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1513,9 +1513,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Nursery", - "lighting_power_density": 0.6, + "lighting_primary_space_type": "Museum", + "lighting_secondary_space_type": "General Exhibition", + "lighting_power_density": 1, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1527,9 +1527,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Operating Room", - "lighting_power_density": 2.2, + "lighting_primary_space_type": "Museum", + "lighting_secondary_space_type": "Restoration", + "lighting_power_density": 1.7, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1541,9 +1541,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Patient Room", - "lighting_power_density": 0.7, + "lighting_primary_space_type": "None", + "lighting_secondary_space_type": "None", + "lighting_power_density": 0, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1555,9 +1555,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Pharmacy", - "lighting_power_density": 1.2, + "lighting_primary_space_type": "Parking Garage garage Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.2, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1569,9 +1569,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Physical Therapy", - "lighting_power_density": 0.9, + "lighting_primary_space_type": "Post Office sorting Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.2, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1583,9 +1583,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Gymnasium/exercise Center", - "lighting_secondary_space_type": "Playing Area", - "lighting_power_density": 1.4, + "lighting_primary_space_type": "Religious Buildings", + "lighting_secondary_space_type": "Fellowship Hall", + "lighting_power_density": 0.9, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1597,9 +1597,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Radiology", - "lighting_power_density": 0.4, + "lighting_primary_space_type": "Religious Buildings", + "lighting_secondary_space_type": "Worship Pulpit, Choir", + "lighting_power_density": 2.4, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1611,9 +1611,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Library", - "lighting_secondary_space_type": "Reading Area", - "lighting_power_density": 1.2, + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Mall Concourse", + "lighting_power_density": 1.7, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1625,9 +1625,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Recovery", - "lighting_power_density": 0.8, + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (Type 1)", + "lighting_power_density": 1, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1639,8 +1639,8 @@ }, { "method": "SS", - "lighting_primary_space_type": "Museum", - "lighting_secondary_space_type": "Restoration", + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (Type 2)", "lighting_power_density": 1.7, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, @@ -1653,9 +1653,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Sports Arena", - "lighting_secondary_space_type": "Ring Sports Area", - "lighting_power_density": 2.7, + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (Type 3)", + "lighting_power_density": 2.6, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1668,8 +1668,8 @@ { "method": "SS", "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Sales Additional (Type 1)", - "lighting_power_density": 1, + "lighting_secondary_space_type": "Sales Additional (Type 4)", + "lighting_power_density": 4.2, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1682,7 +1682,7 @@ { "method": "SS", "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Sales Additional (Type 2)", + "lighting_secondary_space_type": "Sales Area", "lighting_power_density": 1.7, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, @@ -1695,9 +1695,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Sales Additional (Type 3)", - "lighting_power_density": 2.6, + "lighting_primary_space_type": "Sports Arena", + "lighting_secondary_space_type": "Court Sports Area", + "lighting_power_density": 2.3, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1709,9 +1709,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Sales Additional (Type 4)", - "lighting_power_density": 4.2, + "lighting_primary_space_type": "Sports Arena", + "lighting_secondary_space_type": "Indoor Playing Field Area", + "lighting_power_density": 1.4, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1723,9 +1723,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Sales Area", - "lighting_power_density": 1.7, + "lighting_primary_space_type": "Sports Arena", + "lighting_secondary_space_type": "Ring Sports Area", + "lighting_power_density": 2.7, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1737,9 +1737,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Fire Stations", - "lighting_secondary_space_type": "Sleeping Quarters", - "lighting_power_density": 0.3, + "lighting_primary_space_type": "Transportation", + "lighting_secondary_space_type": "Air/Train/Bus Baggage Area", + "lighting_power_density": 1, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1751,9 +1751,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Library", - "lighting_secondary_space_type": "Stacks", - "lighting_power_density": 1.7, + "lighting_primary_space_type": "Transportation", + "lighting_secondary_space_type": "Airport Concourse", + "lighting_power_density": 0.6, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1779,9 +1779,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Religious Buildings", - "lighting_secondary_space_type": "Worship Pulpit, Choir", - "lighting_power_density": 2.4, + "lighting_primary_space_type": "Warehouse", + "lighting_secondary_space_type": "Fine Material Storage", + "lighting_power_density": 1.4, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1793,9 +1793,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "None", - "lighting_secondary_space_type": "None", - "lighting_power_density": 0, + "lighting_primary_space_type": "Warehouse", + "lighting_secondary_space_type": "Medium/Bulky Material Storage", + "lighting_power_density": 0.9, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": null, diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2010.json b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2010.json index 848cefc4fd..6f79187852 100644 --- a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2010.json +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2010.json @@ -163,7 +163,7 @@ "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "REQ", + "automatic_full_off": null, "scheduled_shutoff": null, "annotation": null }, @@ -463,11 +463,11 @@ }, { "method": "CS", - "lighting_primary_space_type": "Audience/seating Area permanent", - "lighting_secondary_space_type": "For auditorium", - "lighting_power_density": 0.79, - "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "lighting_primary_space_type": "Atrium", + "lighting_secondary_space_type": "First 40 ft in height", + "lighting_power_density": 0.03, + "lighting_power_density_unit": "W/ft", + "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -477,25 +477,25 @@ }, { "method": "CS", - "lighting_primary_space_type": "Office", - "lighting_secondary_space_type": "Enclosed", - "lighting_power_density": 1.1, - "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 8, + "lighting_primary_space_type": "Atrium", + "lighting_secondary_space_type": "Height above 40 ft", + "lighting_power_density": 0.02, + "lighting_power_density_unit": "W/ft", + "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "REQ", + "automatic_full_off": null, "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Atrium", - "lighting_secondary_space_type": "First 40 ft in height", - "lighting_power_density": 0.03, - "lighting_power_density_unit": "W/ft", - "rcr_threshold": null, + "lighting_primary_space_type": "Audience/seating Area permanent", + "lighting_secondary_space_type": "For auditorium", + "lighting_power_density": 0.79, + "lighting_power_density_unit": "W/ft2", + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -505,9 +505,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "For Bar Lounge/Leisure Dining", - "lighting_power_density": 1.31, + "lighting_primary_space_type": "Audience/seating Area permanent", + "lighting_secondary_space_type": "For Motion Picture Theater", + "lighting_power_density": 1.14, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -519,11 +519,11 @@ }, { "method": "CS", - "lighting_primary_space_type": "Laboratory", - "lighting_secondary_space_type": "For Classrooms", - "lighting_power_density": 1.28, + "lighting_primary_space_type": "Audience/seating Area permanent", + "lighting_secondary_space_type": "For Performing Arts Theater", + "lighting_power_density": 2.43, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -533,51 +533,51 @@ }, { "method": "CS", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "For Elevator", - "lighting_power_density": 0.64, + "lighting_primary_space_type": "Classroom/Lecture/Training", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.24, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": null, + "automatic_full_off": "REQ", "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "For Family Dining", - "lighting_power_density": 0.89, + "lighting_primary_space_type": "Conference/Meeting/Multipurpose", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.23, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": null, + "automatic_full_off": "REQ", "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Laboratory", - "lighting_secondary_space_type": "For Medical/Industrial/Research", - "lighting_power_density": 1.81, + "lighting_primary_space_type": "Corridor/Transition", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.66, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, "automatic_full_off": null, "scheduled_shutoff": null, - "annotation": null + "annotation": "rcr_threshold: width<8 ft" }, { "method": "CS", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "For Motion Picture Theater", - "lighting_power_density": 0.52, + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "For Bar Lounge/Leisure Dining", + "lighting_power_density": 1.31, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -589,11 +589,11 @@ }, { "method": "CS", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "For Performing Arts Theater", - "lighting_power_density": 2, + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "For Family Dining", + "lighting_power_density": 0.89, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -603,9 +603,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Audience/seating Area permanent", - "lighting_secondary_space_type": "For Motion Picture Theater", - "lighting_power_density": 1.14, + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.65, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -617,53 +617,53 @@ }, { "method": "CS", - "lighting_primary_space_type": "Classroom/Lecture/Training", + "lighting_primary_space_type": "Dressing/Fitting Room For Performing Arts Theater", "lighting_secondary_space_type": "General", - "lighting_power_density": 1.24, + "lighting_power_density": 0.4, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "REQ", + "automatic_full_off": null, "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Conference/Meeting/Multipurpose", + "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", - "lighting_power_density": 1.23, + "lighting_power_density": 0.95, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "REQ", + "automatic_full_off": null, "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Corridor/Transition", + "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", - "lighting_power_density": 0.66, + "lighting_power_density": 0.99, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": null, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, "automatic_full_off": null, "scheduled_shutoff": null, - "annotation": "rcr_threshold: width<8 ft" + "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.65, + "lighting_primary_space_type": "Laboratory", + "lighting_secondary_space_type": "For Classrooms", + "lighting_power_density": 1.28, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -673,9 +673,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Dressing/Fitting Room For Performing Arts Theater", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.4, + "lighting_primary_space_type": "Laboratory", + "lighting_secondary_space_type": "For Medical/Industrial/Research", + "lighting_power_density": 1.81, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -687,9 +687,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Electrical/Mechanical", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.95, + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "For Elevator", + "lighting_power_density": 0.64, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -701,9 +701,23 @@ }, { "method": "CS", - "lighting_primary_space_type": "Food Preparation", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.99, + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "For Motion Picture Theater", + "lighting_power_density": 0.52, + "lighting_power_density_unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "For Performing Arts Theater", + "lighting_power_density": 2, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -755,6 +769,34 @@ "scheduled_shutoff": null, "annotation": null }, + { + "method": "CS", + "lighting_primary_space_type": "Office", + "lighting_secondary_space_type": "Enclosed", + "lighting_power_density": 1.1, + "lighting_power_density_unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Office", + "lighting_secondary_space_type": "Open Plan", + "lighting_power_density": 0.98, + "lighting_power_density_unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, { "method": "CS", "lighting_primary_space_type": "Restrooms", @@ -826,12 +868,12 @@ "annotation": null }, { - "method": "CS", - "lighting_primary_space_type": "Atrium", - "lighting_secondary_space_type": "Height above 40 ft", - "lighting_power_density": 0.02, - "lighting_power_density_unit": "W/ft", - "rcr_threshold": null, + "method": "SS", + "lighting_primary_space_type": "Automotive", + "lighting_secondary_space_type": "Service/Repair", + "lighting_power_density": 0.67, + "lighting_power_density_unit": "W/ft2", + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -840,12 +882,12 @@ "annotation": null }, { - "method": "CS", - "lighting_primary_space_type": "Audience/seating Area permanent", - "lighting_secondary_space_type": "For Performing Arts Theater", - "lighting_power_density": 2.43, + "method": "SS", + "lighting_primary_space_type": "Bank/Office", + "lighting_secondary_space_type": "Banking Activity Area", + "lighting_power_density": 1.38, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 8, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -854,10 +896,10 @@ "annotation": null }, { - "method": "CS", - "lighting_primary_space_type": "Office", - "lighting_secondary_space_type": "Open Plan", - "lighting_power_density": 0.98, + "method": "SS", + "lighting_primary_space_type": "Convention Center", + "lighting_secondary_space_type": "Audience Seating", + "lighting_power_density": 0.82, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -869,9 +911,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Transportation", - "lighting_secondary_space_type": "Air/Train/Bus Baggage Area", - "lighting_power_density": 0.76, + "lighting_primary_space_type": "Convention Center", + "lighting_secondary_space_type": "Exhibit Space", + "lighting_power_density": 1.45, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -883,11 +925,11 @@ }, { "method": "SS", - "lighting_primary_space_type": "Transportation", - "lighting_secondary_space_type": "Airport Concourse", - "lighting_power_density": 0.36, + "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", + "lighting_secondary_space_type": "Confinement Cells", + "lighting_power_density": 1.1, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -897,11 +939,11 @@ }, { "method": "SS", - "lighting_primary_space_type": "Convention Center", - "lighting_secondary_space_type": "Audience Seating", - "lighting_power_density": 0.82, + "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", + "lighting_secondary_space_type": "Courtroom", + "lighting_power_density": 1.72, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -911,11 +953,11 @@ }, { "method": "SS", - "lighting_primary_space_type": "Religious Buildings", - "lighting_secondary_space_type": "Audience Seating", - "lighting_power_density": 1.53, + "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", + "lighting_secondary_space_type": "Judges' Chambers", + "lighting_power_density": 1.17, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -925,8 +967,8 @@ }, { "method": "SS", - "lighting_primary_space_type": "Sports Arena", - "lighting_secondary_space_type": "Audience Seating", + "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", + "lighting_secondary_space_type": "Penitentiary Audience Seating", "lighting_power_density": 0.43, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, @@ -939,51 +981,23 @@ }, { "method": "SS", - "lighting_primary_space_type": "Transportation", - "lighting_secondary_space_type": "Audience Seating", - "lighting_power_density": 0.54, - "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", - "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, - "automatic_full_off": null, - "scheduled_shutoff": null, - "annotation": null - }, - { - "method": "SS", - "lighting_primary_space_type": "Bank/Office", - "lighting_secondary_space_type": "Banking Activity Area", - "lighting_power_density": 1.38, - "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", - "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, - "automatic_full_off": null, - "scheduled_shutoff": null, - "annotation": null - }, - { - "method": "SS", - "lighting_primary_space_type": "Library", - "lighting_secondary_space_type": "Card File and Cataloging", - "lighting_power_density": 0.72, + "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", + "lighting_secondary_space_type": "Penitentiary Classroom", + "lighting_power_density": 1.34, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": null, + "automatic_full_off": "REQ", "scheduled_shutoff": null, "annotation": null }, { "method": "SS", "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", - "lighting_secondary_space_type": "Confinement Cells", - "lighting_power_density": 1.1, + "lighting_secondary_space_type": "Penitentiary Dining", + "lighting_power_density": 1.07, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -995,39 +1009,11 @@ }, { "method": "SS", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Corridor/Transition", - "lighting_power_density": 0.89, - "lighting_power_density_unit": "W/ft2", - "rcr_threshold": null, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", - "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, - "automatic_full_off": null, - "scheduled_shutoff": null, - "annotation": "rcr_threshold: width<8 ft" - }, - { - "method": "SS", - "lighting_primary_space_type": "Manufacturing", - "lighting_secondary_space_type": "Corridor/Transition", - "lighting_power_density": 0.41, - "lighting_power_density_unit": "W/ft2", - "rcr_threshold": null, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", - "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, - "automatic_full_off": null, - "scheduled_shutoff": null, - "annotation": "rcr_threshold: width<8 ft" - }, - { - "method": "SS", - "lighting_primary_space_type": "Sports Arena", - "lighting_secondary_space_type": "Court Sports Arena Class 1", - "lighting_power_density": 3.01, + "lighting_primary_space_type": "Dormitory", + "lighting_secondary_space_type": "Living Quarters", + "lighting_power_density": 0.38, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1037,9 +1023,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Sports Arena", - "lighting_secondary_space_type": "Court Sports Arena Class 2", - "lighting_power_density": 1.92, + "lighting_primary_space_type": "Fire Stations", + "lighting_secondary_space_type": "Engine Room", + "lighting_power_density": 0.56, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1051,11 +1037,11 @@ }, { "method": "SS", - "lighting_primary_space_type": "Sports Arena", - "lighting_secondary_space_type": "Court Sports Arena Class 3", - "lighting_power_density": 1.2, + "lighting_primary_space_type": "Fire Stations", + "lighting_secondary_space_type": "Sleeping Quarters", + "lighting_power_density": 0.25, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1065,8 +1051,8 @@ }, { "method": "SS", - "lighting_primary_space_type": "Sports Arena", - "lighting_secondary_space_type": "Court Sports Arena Class 4", + "lighting_primary_space_type": "Gymnasium/fitness Center", + "lighting_secondary_space_type": "Exercise Area", "lighting_power_density": 0.72, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, @@ -1079,9 +1065,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", - "lighting_secondary_space_type": "Courtroom", - "lighting_power_density": 1.72, + "lighting_primary_space_type": "Gymnasium/fitness Center", + "lighting_secondary_space_type": "Gymnasium Audience Seating", + "lighting_power_density": 0.43, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1093,9 +1079,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Manufacturing", - "lighting_secondary_space_type": "Detailed Manufacturing", - "lighting_power_density": 1.29, + "lighting_primary_space_type": "Gymnasium/fitness Center", + "lighting_secondary_space_type": "Playing Area", + "lighting_power_density": 1.2, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1107,17 +1093,17 @@ }, { "method": "SS", - "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Dressing/Fitting Room", - "lighting_power_density": 0.87, + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Corridor/Transition", + "lighting_power_density": 0.89, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 8, + "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, "automatic_full_off": null, "scheduled_shutoff": null, - "annotation": null + "annotation": "rcr_threshold: width<8 ft" }, { "method": "SS", @@ -1135,25 +1121,11 @@ }, { "method": "SS", - "lighting_primary_space_type": "Fire Stations", - "lighting_secondary_space_type": "Engine Room", - "lighting_power_density": 0.56, - "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", - "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, - "automatic_full_off": null, - "scheduled_shutoff": null, - "annotation": null - }, - { - "method": "SS", - "lighting_primary_space_type": "Manufacturing", - "lighting_secondary_space_type": "Equipment Room", - "lighting_power_density": 0.95, + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Exam/Treatment", + "lighting_power_density": 1.66, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1164,10 +1136,10 @@ { "method": "SS", "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Exam/Treatment", - "lighting_power_density": 1.66, + "lighting_secondary_space_type": "Laundry/Washing", + "lighting_power_density": 0.6, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 8, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1177,39 +1149,39 @@ }, { "method": "SS", - "lighting_primary_space_type": "Gymnasium/fitness Center", - "lighting_secondary_space_type": "Exercise Area", - "lighting_power_density": 0.72, + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Lounge/Recreation", + "lighting_power_density": 1.07, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": null, + "automatic_full_off": "REQ", "scheduled_shutoff": null, "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Convention Center", - "lighting_secondary_space_type": "Exhibit Space", - "lighting_power_density": 1.45, + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Medical Supply", + "lighting_power_density": 1.27, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": null, + "automatic_full_off": "REQ", "scheduled_shutoff": null, "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Manufacturing", - "lighting_secondary_space_type": "Extra High Bay (>50 ft Floor to Ceiling Height)", - "lighting_power_density": 1.05, + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Nursery", + "lighting_power_density": 0.88, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1219,11 +1191,11 @@ }, { "method": "SS", - "lighting_primary_space_type": "Religious Buildings", - "lighting_secondary_space_type": "Fellowship Hall", - "lighting_power_density": 0.64, + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Nurses' Station", + "lighting_power_density": 0.87, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1233,9 +1205,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Warehouse", - "lighting_secondary_space_type": "Fine Material Storage", - "lighting_power_density": 0.95, + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Operating Room", + "lighting_power_density": 1.89, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1247,11 +1219,11 @@ }, { "method": "SS", - "lighting_primary_space_type": "Parking Garage", - "lighting_secondary_space_type": "Garage Area", - "lighting_power_density": 0.19, + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Patient Room", + "lighting_power_density": 0.62, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1261,11 +1233,11 @@ }, { "method": "SS", - "lighting_primary_space_type": "Post Office Sorting Area", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.94, + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Pharmacy", + "lighting_power_density": 1.14, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1275,9 +1247,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Museum", - "lighting_secondary_space_type": "General Exhibition", - "lighting_power_density": 1.05, + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Physical Therapy", + "lighting_power_density": 0.91, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1289,9 +1261,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Gymnasium/fitness Center", - "lighting_secondary_space_type": "Gymnasium Audience Seating", - "lighting_power_density": 0.43, + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Radiology/Imaging", + "lighting_power_density": 1.32, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1303,11 +1275,11 @@ }, { "method": "SS", - "lighting_primary_space_type": "Manufacturing", - "lighting_secondary_space_type": "High Bay (25-50 ft Floor to Ceiling Height)", - "lighting_power_density": 1.23, + "lighting_primary_space_type": "Hospital", + "lighting_secondary_space_type": "Recovery", + "lighting_power_density": 1.15, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1387,11 +1359,11 @@ }, { "method": "SS", - "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", - "lighting_secondary_space_type": "Judges' Chambers", - "lighting_power_density": 1.17, + "lighting_primary_space_type": "Library", + "lighting_secondary_space_type": "Card File and Cataloging", + "lighting_power_density": 0.72, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 8, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1401,9 +1373,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Laundry/Washing", - "lighting_power_density": 0.6, + "lighting_primary_space_type": "Library", + "lighting_secondary_space_type": "Reading Area", + "lighting_power_density": 0.93, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1415,11 +1387,11 @@ }, { "method": "SS", - "lighting_primary_space_type": "Dormitory", - "lighting_secondary_space_type": "Living Quarters", - "lighting_power_density": 0.38, + "lighting_primary_space_type": "Library", + "lighting_secondary_space_type": "Stacks", + "lighting_power_density": 1.71, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 8, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1429,23 +1401,23 @@ }, { "method": "SS", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Lounge/Recreation", - "lighting_power_density": 1.07, + "lighting_primary_space_type": "Manufacturing", + "lighting_secondary_space_type": "Corridor/Transition", + "lighting_power_density": 0.41, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "REQ", + "automatic_full_off": null, "scheduled_shutoff": null, - "annotation": null + "annotation": "rcr_threshold: width<8 ft" }, { "method": "SS", "lighting_primary_space_type": "Manufacturing", - "lighting_secondary_space_type": "Low Bay (<25 ft Floor to Ceiling Height)", - "lighting_power_density": 1.19, + "lighting_secondary_space_type": "Detailed Manufacturing", + "lighting_power_density": 1.29, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1457,11 +1429,11 @@ }, { "method": "SS", - "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Mall Concourse", - "lighting_power_density": 1.1, + "lighting_primary_space_type": "Manufacturing", + "lighting_secondary_space_type": "Equipment Room", + "lighting_power_density": 0.95, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1471,23 +1443,23 @@ }, { "method": "SS", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Medical Supply", - "lighting_power_density": 1.27, + "lighting_primary_space_type": "Manufacturing", + "lighting_secondary_space_type": "Extra High Bay (>50 ft Floor to Ceiling Height)", + "lighting_power_density": 1.05, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "REQ", + "automatic_full_off": null, "scheduled_shutoff": null, "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Warehouse", - "lighting_secondary_space_type": "Medium/Bulky Material Storage", - "lighting_power_density": 0.58, + "lighting_primary_space_type": "Manufacturing", + "lighting_secondary_space_type": "High Bay (25-50 ft Floor to Ceiling Height)", + "lighting_power_density": 1.23, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1499,11 +1471,11 @@ }, { "method": "SS", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Nursery", - "lighting_power_density": 0.88, + "lighting_primary_space_type": "Manufacturing", + "lighting_secondary_space_type": "Low Bay (<25 ft Floor to Ceiling Height)", + "lighting_power_density": 1.19, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1513,9 +1485,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Nurses' Station", - "lighting_power_density": 0.87, + "lighting_primary_space_type": "Museum", + "lighting_secondary_space_type": "General Exhibition", + "lighting_power_density": 1.05, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1527,9 +1499,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Operating Room", - "lighting_power_density": 1.89, + "lighting_primary_space_type": "Museum", + "lighting_secondary_space_type": "Restoration", + "lighting_power_density": 1.02, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1541,11 +1513,25 @@ }, { "method": "SS", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Patient Room", - "lighting_power_density": 0.62, + "lighting_primary_space_type": "None", + "lighting_secondary_space_type": "None", + "lighting_power_density": 0, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Parking Garage", + "lighting_secondary_space_type": "Garage Area", + "lighting_power_density": 0.19, + "lighting_power_density_unit": "W/ft2", + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1555,9 +1541,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", - "lighting_secondary_space_type": "Penitentiary Audience Seating", - "lighting_power_density": 0.43, + "lighting_primary_space_type": "Post Office Sorting Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.94, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1569,25 +1555,25 @@ }, { "method": "SS", - "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", - "lighting_secondary_space_type": "Penitentiary Classroom", - "lighting_power_density": 1.34, + "lighting_primary_space_type": "Religious Buildings", + "lighting_secondary_space_type": "Audience Seating", + "lighting_power_density": 1.53, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "REQ", + "automatic_full_off": null, "scheduled_shutoff": null, "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Courthouse/Police Station/Penitentiary", - "lighting_secondary_space_type": "Penitentiary Dining", - "lighting_power_density": 1.07, + "lighting_primary_space_type": "Religious Buildings", + "lighting_secondary_space_type": "Fellowship Hall", + "lighting_power_density": 0.64, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1597,11 +1583,11 @@ }, { "method": "SS", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Pharmacy", - "lighting_power_density": 1.14, + "lighting_primary_space_type": "Religious Buildings", + "lighting_secondary_space_type": "Worship Pulpit, Choir", + "lighting_power_density": 1.53, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1611,11 +1597,11 @@ }, { "method": "SS", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Physical Therapy", - "lighting_power_density": 0.91, + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Dressing/Fitting Room", + "lighting_power_density": 0.87, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1625,9 +1611,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Gymnasium/fitness Center", - "lighting_secondary_space_type": "Playing Area", - "lighting_power_density": 1.2, + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Mall Concourse", + "lighting_power_density": 1.1, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1639,12 +1625,12 @@ }, { "method": "SS", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Radiology/Imaging", - "lighting_power_density": 1.32, + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (Type 1)", + "lighting_power_density": 0.6, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, "automatic_full_off": null, @@ -1653,12 +1639,12 @@ }, { "method": "SS", - "lighting_primary_space_type": "Library", - "lighting_secondary_space_type": "Reading Area", - "lighting_power_density": 0.93, + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (Type 2)", + "lighting_power_density": 0.6, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, "automatic_full_off": null, @@ -1667,12 +1653,12 @@ }, { "method": "SS", - "lighting_primary_space_type": "Hospital", - "lighting_secondary_space_type": "Recovery", - "lighting_power_density": 1.15, + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (Type 3)", + "lighting_power_density": 1.4, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, "automatic_full_off": null, @@ -1681,12 +1667,26 @@ }, { "method": "SS", - "lighting_primary_space_type": "Museum", - "lighting_secondary_space_type": "Restoration", - "lighting_power_density": 1.02, + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (Type 4)", + "lighting_power_density": 2.5, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Area", + "lighting_power_density": 1.68, + "lighting_power_density_unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, "automatic_full_off": null, @@ -1696,8 +1696,8 @@ { "method": "SS", "lighting_primary_space_type": "Sports Arena", - "lighting_secondary_space_type": "Ring Sports Area", - "lighting_power_density": 2.68, + "lighting_secondary_space_type": "Audience Seating", + "lighting_power_density": 0.43, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1709,12 +1709,12 @@ }, { "method": "SS", - "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Sales Additional (Type 1)", - "lighting_power_density": 0.6, + "lighting_primary_space_type": "Sports Arena", + "lighting_secondary_space_type": "Court Sports Arena Class 1", + "lighting_power_density": 3.01, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": null, + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, "automatic_full_off": null, @@ -1723,12 +1723,12 @@ }, { "method": "SS", - "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Sales Additional (Type 2)", - "lighting_power_density": 0.6, + "lighting_primary_space_type": "Sports Arena", + "lighting_secondary_space_type": "Court Sports Arena Class 2", + "lighting_power_density": 1.92, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": null, + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, "automatic_full_off": null, @@ -1737,12 +1737,12 @@ }, { "method": "SS", - "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Sales Additional (Type 3)", - "lighting_power_density": 1.4, + "lighting_primary_space_type": "Sports Arena", + "lighting_secondary_space_type": "Court Sports Arena Class 3", + "lighting_power_density": 1.2, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": null, + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, "automatic_full_off": null, @@ -1751,12 +1751,12 @@ }, { "method": "SS", - "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Sales Additional (Type 4)", - "lighting_power_density": 2.5, + "lighting_primary_space_type": "Sports Arena", + "lighting_secondary_space_type": "Court Sports Arena Class 4", + "lighting_power_density": 0.72, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": null, + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, "automatic_full_off": null, @@ -1765,12 +1765,12 @@ }, { "method": "SS", - "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Sales Area", - "lighting_power_density": 1.68, + "lighting_primary_space_type": "Sports Arena", + "lighting_secondary_space_type": "Ring Sports Area", + "lighting_power_density": 2.68, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": null, + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, "automatic_full_off": null, @@ -1779,9 +1779,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Automotive", - "lighting_secondary_space_type": "Service/Repair", - "lighting_power_density": 0.67, + "lighting_primary_space_type": "Transportation", + "lighting_secondary_space_type": "Air/Train/Bus Baggage Area", + "lighting_power_density": 0.76, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1793,11 +1793,11 @@ }, { "method": "SS", - "lighting_primary_space_type": "Fire Stations", - "lighting_secondary_space_type": "Sleeping Quarters", - "lighting_power_density": 0.25, + "lighting_primary_space_type": "Transportation", + "lighting_secondary_space_type": "Airport Concourse", + "lighting_power_density": 0.36, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1807,9 +1807,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Library", - "lighting_secondary_space_type": "Stacks", - "lighting_power_density": 1.71, + "lighting_primary_space_type": "Transportation", + "lighting_secondary_space_type": "Audience Seating", + "lighting_power_density": 0.54, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1835,11 +1835,11 @@ }, { "method": "SS", - "lighting_primary_space_type": "Religious Buildings", - "lighting_secondary_space_type": "Worship Pulpit, Choir", - "lighting_power_density": 1.53, + "lighting_primary_space_type": "Warehouse", + "lighting_secondary_space_type": "Fine Material Storage", + "lighting_power_density": 0.95, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1849,13 +1849,13 @@ }, { "method": "SS", - "lighting_primary_space_type": "None", - "lighting_secondary_space_type": "None", - "lighting_power_density": 0, + "lighting_primary_space_type": "Warehouse", + "lighting_secondary_space_type": "Medium/Bulky Material Storage", + "lighting_power_density": 0.58, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": null, - "automatic_daylight_responsive_controls_for_sidelighting": null, - "automatic_daylight_responsive_controls_for_toplighting": null, + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, "automatic_full_off": null, "scheduled_shutoff": null, diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2013.json b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2013.json index 0e69db14b9..3ad0d87414 100644 --- a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2013.json +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2013.json @@ -461,20 +461,6 @@ "scheduled_shutoff": "ADD2", "annotation": "LP-Height" }, - { - "method": "CS", - "lighting_primary_space_type": "Storage Room", - "lighting_secondary_space_type": "<50 ft2", - "lighting_power_density": 1.24, - "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": null, - "automatic_daylight_responsive_controls_for_toplighting": null, - "automatic_partial_off": null, - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", - "annotation": null - }, { "method": "CS", "lighting_primary_space_type": "Atrium", @@ -503,20 +489,6 @@ "scheduled_shutoff": "ADD2", "annotation": "LP-Height" }, - { - "method": "CS", - "lighting_primary_space_type": "Storage Room", - "lighting_secondary_space_type": "gt 50 ft2 and lt 1000 ft2", - "lighting_power_density": 0.63, - "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", - "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, - "automatic_full_off": "REQ", - "scheduled_shutoff": null, - "annotation": null - }, { "method": "CS", "lighting_primary_space_type": "Audience/seating Area", @@ -533,37 +505,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Classroom/Lecture Hall/Training Room", - "lighting_secondary_space_type": "all other classrooms/lecture halls/training rooms", - "lighting_power_density": 1.24, - "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", - "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, - "automatic_full_off": "REQ", - "scheduled_shutoff": null, - "annotation": null - }, - { - "method": "CS", - "lighting_primary_space_type": "Corridor", - "lighting_secondary_space_type": "all other corridors", - "lighting_power_density": 0.66, - "lighting_power_density_unit": "W/ft2", - "rcr_threshold": null, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", - "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", - "annotation": "rcr_threshold: width<8 ft" - }, - { - "method": "CS", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "all other dining areas", - "lighting_power_density": 0.65, + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "in a convention center", + "lighting_power_density": 0.82, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -575,9 +519,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Laboratory", - "lighting_secondary_space_type": "all other laboratories", - "lighting_power_density": 1.81, + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "in a gymnasium", + "lighting_power_density": 0.65, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -589,98 +533,42 @@ }, { "method": "CS", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "all other lobbies", - "lighting_power_density": 0.9, + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "in a motion picture theater", + "lighting_power_density": 1.14, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", + "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Lounge/Breakroom", - "lighting_secondary_space_type": "all other lounges/breakrooms", - "lighting_power_density": 0.73, + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "in a penitentiary", + "lighting_power_density": 0.28, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "REQ", - "scheduled_shutoff": null, - "annotation": null - }, - { - "method": "CS", - "lighting_primary_space_type": "Restroom", - "lighting_secondary_space_type": "all other restrooms", - "lighting_power_density": 0.98, - "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 8, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", - "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, - "automatic_full_off": "REQ", - "scheduled_shutoff": null, - "annotation": null - }, - { - "method": "CS", - "lighting_primary_space_type": "Storage Room", - "lighting_secondary_space_type": "all other storage rooms", - "lighting_power_density": 0.63, - "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", - "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Office", - "lighting_secondary_space_type": "enclosed and >250 ft2", - "lighting_power_density": 1.11, - "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 8, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", - "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, - "automatic_full_off": "ADD2", - "scheduled_shutoff": null, - "annotation": null - }, - { - "method": "CS", - "lighting_primary_space_type": "Office", - "lighting_secondary_space_type": "enclosed and lt 250 ft2", - "lighting_power_density": 1.11, + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "in a performing arts theater", + "lighting_power_density": 2.43, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "REQ", - "scheduled_shutoff": null, - "annotation": null - }, - { - "method": "CS", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "for an elevator", - "lighting_power_density": 0.64, - "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", - "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null @@ -688,10 +576,10 @@ { "method": "CS", "lighting_primary_space_type": "Audience/seating Area", - "lighting_secondary_space_type": "in an auditorium", - "lighting_power_density": 0.63, + "lighting_secondary_space_type": "in a religious building", + "lighting_power_density": 1.53, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -702,8 +590,8 @@ { "method": "CS", "lighting_primary_space_type": "Audience/seating Area", - "lighting_secondary_space_type": "in a convention center", - "lighting_power_density": 0.82, + "lighting_secondary_space_type": "in a sports arena", + "lighting_power_density": 0.43, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -715,11 +603,11 @@ }, { "method": "CS", - "lighting_primary_space_type": "Seating Area, General", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.54, + "lighting_primary_space_type": "Audience/seating Area", + "lighting_secondary_space_type": "in an auditorium", + "lighting_power_density": 0.63, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -729,9 +617,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Audience/seating Area", - "lighting_secondary_space_type": "in a gymnasium", - "lighting_power_density": 0.65, + "lighting_primary_space_type": "Banking Activity Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.01, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -743,37 +631,37 @@ }, { "method": "CS", - "lighting_primary_space_type": "Audience/seating Area", - "lighting_secondary_space_type": "in a motion picture theater", - "lighting_power_density": 1.14, + "lighting_primary_space_type": "Breakroom", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.73, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", + "automatic_full_off": "REQ", + "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Banking Activity Area", - "lighting_secondary_space_type": "General", - "lighting_power_density": 1.01, + "lighting_primary_space_type": "Classroom/Lecture Hall/Training Room", + "lighting_secondary_space_type": "all other classrooms/lecture halls/training rooms", + "lighting_power_density": 1.24, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", + "automatic_full_off": "REQ", + "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Breakroom", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.73, + "lighting_primary_space_type": "Classroom/Lecture Hall/Training Room", + "lighting_secondary_space_type": "in a penitentiary", + "lighting_power_density": 1.34, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -841,79 +729,79 @@ }, { "method": "CS", - "lighting_primary_space_type": "Courtroom", - "lighting_secondary_space_type": "General", - "lighting_power_density": 1.72, + "lighting_primary_space_type": "Corridor", + "lighting_secondary_space_type": "all other corridors", + "lighting_power_density": 0.66, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, + "automatic_partial_off": "REQ", "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", - "annotation": null + "annotation": "rcr_threshold: width<8 ft" }, { "method": "CS", - "lighting_primary_space_type": "Electrical/Mechanical Room", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.42, + "lighting_primary_space_type": "Corridor", + "lighting_secondary_space_type": "in a facility for the visually impaired (and not used primarily by the staff)", + "lighting_power_density": 0.92, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, - "automatic_full_off": null, - "scheduled_shutoff": null, - "annotation": null + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": "rcr_threshold: width<8 ft" }, { "method": "CS", - "lighting_primary_space_type": "Emergency Vehicle Garage", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.56, + "lighting_primary_space_type": "Corridor", + "lighting_secondary_space_type": "in a hospital", + "lighting_power_density": 0.99, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, + "automatic_partial_off": "ADD2", "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", - "annotation": null + "annotation": "rcr_threshold: width<8 ft" }, { "method": "CS", - "lighting_primary_space_type": "Food Preparation Area", - "lighting_secondary_space_type": "General", - "lighting_power_density": 1.21, + "lighting_primary_space_type": "Corridor", + "lighting_secondary_space_type": "in a manufacturing facility", + "lighting_power_density": 0.41, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", - "annotation": null + "annotation": "rcr_threshold: width<8 ft" }, { "method": "CS", - "lighting_primary_space_type": "Guest Room", + "lighting_primary_space_type": "Courtroom", "lighting_secondary_space_type": "General", - "lighting_power_density": 0.91, + "lighting_power_density": 1.72, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": null, - "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "REQ", - "scheduled_shutoff": null, - "annotation": "See Section 9.4.1.3b" + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Laundry/Washing Area", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.6, + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "all other dining areas", + "lighting_power_density": 0.65, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -925,11 +813,11 @@ }, { "method": "CS", - "lighting_primary_space_type": "Loading Dock, Interior", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.47, + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "in a facility for the visually impaired (and not used primarily by staff)", + "lighting_power_density": 2.65, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -939,39 +827,25 @@ }, { "method": "CS", - "lighting_primary_space_type": "Locker Room", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.75, + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "in a penitentiary", + "lighting_power_density": 0.96, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "REQ", - "scheduled_shutoff": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Parking Area, Interior", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.19, + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "in bar/lounge or leisure dining", + "lighting_power_density": 1.07, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, - "automatic_daylight_responsive_controls_for_sidelighting": null, - "automatic_daylight_responsive_controls_for_toplighting": null, - "automatic_partial_off": "REQ", - "automatic_full_off": null, - "scheduled_shutoff": null, - "annotation": "See Section 9.4.1.2" - }, - { - "method": "CS", - "lighting_primary_space_type": "Pharmacy Area", - "lighting_secondary_space_type": "General", - "lighting_power_density": 1.68, - "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -981,12 +855,12 @@ }, { "method": "CS", - "lighting_primary_space_type": "Sales Area", - "lighting_secondary_space_type": "General", - "lighting_power_density": 1.44, + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "in cafeteria or fast food dining", + "lighting_power_density": 0.65, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": null, + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, "automatic_full_off": "ADD2", @@ -995,9 +869,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Audience/seating Area", - "lighting_secondary_space_type": "in a penitentiary", - "lighting_power_density": 0.28, + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "in family dining", + "lighting_power_density": 0.89, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1009,39 +883,39 @@ }, { "method": "CS", - "lighting_primary_space_type": "Stairway", + "lighting_primary_space_type": "Electrical/Mechanical Room", "lighting_secondary_space_type": "General", - "lighting_power_density": 0.69, + "lighting_power_density": 0.42, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 10, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Stairwell", + "lighting_primary_space_type": "Emergency Vehicle Garage", "lighting_secondary_space_type": "General", - "lighting_power_density": 0.69, + "lighting_power_density": 0.56, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 10, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", + "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Vehicular Maintenance Area", + "lighting_primary_space_type": "Food Preparation Area", "lighting_secondary_space_type": "General", - "lighting_power_density": 0.67, + "lighting_power_density": 1.21, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1051,25 +925,25 @@ }, { "method": "CS", - "lighting_primary_space_type": "Workshop", + "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "General", - "lighting_power_density": 1.59, + "lighting_power_density": 0.91, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", - "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, "automatic_partial_off": null, - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", - "annotation": null + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": "See Section 9.4.1.3b" }, { "method": "CS", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "in a facility for the visually impaired (and not used primarily by staff)", - "lighting_power_density": 2.65, + "lighting_primary_space_type": "Laboratory", + "lighting_secondary_space_type": "all other laboratories", + "lighting_power_density": 1.81, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1079,101 +953,101 @@ }, { "method": "CS", - "lighting_primary_space_type": "Corridor", - "lighting_secondary_space_type": "in a facility for the visually impaired (and not used primarily by the staff)", - "lighting_power_density": 0.92, + "lighting_primary_space_type": "Laboratory", + "lighting_secondary_space_type": "in or as a classroom", + "lighting_power_density": 1.43, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": null, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": "REQ", "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", - "annotation": "rcr_threshold: width<8 ft" + "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "in a facility for the visually impaired (and not used primarily by the staff)", - "lighting_power_density": 1.8, + "lighting_primary_space_type": "Laundry/Washing Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.6, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", + "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Restroom", - "lighting_secondary_space_type": "in a facility for the visually impaired (and not used primarily by the staff)", - "lighting_power_density": 1.21, + "lighting_primary_space_type": "Loading Dock, Interior", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.47, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 8, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "REQ", - "scheduled_shutoff": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Lounge/Breakroom", - "lighting_secondary_space_type": "in a healthcare facility", - "lighting_power_density": 0.92, + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "all other lobbies", + "lighting_power_density": 0.9, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, - "automatic_full_off": "REQ", - "scheduled_shutoff": null, + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Corridor", - "lighting_secondary_space_type": "in a hospital", - "lighting_power_density": 0.99, + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "for an elevator", + "lighting_power_density": 0.64, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": null, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "ADD2", + "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", - "annotation": "rcr_threshold: width<8 ft" + "annotation": null }, { "method": "CS", "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "in a hotel", - "lighting_power_density": 1.06, + "lighting_secondary_space_type": "in a facility for the visually impaired (and not used primarily by the staff)", + "lighting_power_density": 1.8, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, + "automatic_partial_off": "REQ", "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Corridor", - "lighting_secondary_space_type": "in a manufacturing facility", - "lighting_power_density": 0.41, + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "in a hotel", + "lighting_power_density": 1.06, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": null, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", - "annotation": "rcr_threshold: width<8 ft" + "annotation": null }, { "method": "CS", @@ -1191,25 +1065,25 @@ }, { "method": "CS", - "lighting_primary_space_type": "Audience/seating Area", + "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "in a performing arts theater", - "lighting_power_density": 2.43, + "lighting_power_density": 2, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 8, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, + "automatic_partial_off": "REQ", "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Classroom/Lecture Hall/Training Room", - "lighting_secondary_space_type": "in a penitentiary", - "lighting_power_density": 1.34, + "lighting_primary_space_type": "Locker Room", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.75, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1219,65 +1093,65 @@ }, { "method": "CS", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "in a penitentiary", - "lighting_power_density": 0.96, + "lighting_primary_space_type": "Lounge/Breakroom", + "lighting_secondary_space_type": "all other lounges/breakrooms", + "lighting_power_density": 0.73, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", + "automatic_full_off": "REQ", + "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "in a performing arts theater", - "lighting_power_density": 2, + "lighting_primary_space_type": "Lounge/Breakroom", + "lighting_secondary_space_type": "in a healthcare facility", + "lighting_power_density": 0.92, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "in bar/lounge or leisure dining", - "lighting_power_density": 1.07, + "lighting_primary_space_type": "Office", + "lighting_secondary_space_type": "enclosed and >250 ft2", + "lighting_power_density": 1.11, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", + "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "in cafeteria or fast food dining", - "lighting_power_density": 0.65, + "lighting_primary_space_type": "Office", + "lighting_secondary_space_type": "enclosed and lt 250 ft2", + "lighting_power_density": 1.11, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", + "automatic_full_off": "REQ", + "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "in family dining", - "lighting_power_density": 0.89, + "lighting_primary_space_type": "Office", + "lighting_secondary_space_type": "open plan", + "lighting_power_density": 0.98, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1289,54 +1163,68 @@ }, { "method": "CS", - "lighting_primary_space_type": "Laboratory", - "lighting_secondary_space_type": "in or as a classroom", - "lighting_power_density": 1.43, - "lighting_power_density_unit": "W/ft2", + "lighting_primary_space_type": "Parking Area, Interior", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.19, + "lighting_power_density_unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": "REQ", + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": "See Section 9.4.1.2" + }, + { + "method": "CS", + "lighting_primary_space_type": "Pharmacy Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.68, + "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", + "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Audience/seating Area", - "lighting_secondary_space_type": "in a religious building", - "lighting_power_density": 1.53, + "lighting_primary_space_type": "Restroom", + "lighting_secondary_space_type": "all other restrooms", + "lighting_power_density": 0.98, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", + "automatic_full_off": "REQ", + "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Office", - "lighting_secondary_space_type": "open plan", - "lighting_power_density": 0.98, + "lighting_primary_space_type": "Restroom", + "lighting_secondary_space_type": "in a facility for the visually impaired (and not used primarily by the staff)", + "lighting_power_density": 1.21, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", + "automatic_full_off": "REQ", + "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Audience/seating Area", - "lighting_secondary_space_type": "in a sports arena", - "lighting_power_density": 0.43, + "lighting_primary_space_type": "Sales Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.44, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, "automatic_full_off": "ADD2", @@ -1344,10 +1232,10 @@ "annotation": null }, { - "method": "SS", - "lighting_primary_space_type": "Religious Buildings", - "lighting_secondary_space_type": "a worship/pulpit/choir area", - "lighting_power_density": 1.53, + "method": "CS", + "lighting_primary_space_type": "Seating Area, General", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.54, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1358,99 +1246,99 @@ "annotation": null }, { - "method": "SS", - "lighting_primary_space_type": "Transportation Facility", - "lighting_secondary_space_type": "at a terminal ticket counter", - "lighting_power_density": 0.8, + "method": "CS", + "lighting_primary_space_type": "Stairway", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.69, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 10, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, + "automatic_partial_off": "REQ", "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { - "method": "SS", - "lighting_primary_space_type": "Sports Arena Playing Area", - "lighting_secondary_space_type": "for a Class I facility", - "lighting_power_density": 3.68, + "method": "CS", + "lighting_primary_space_type": "Stairwell", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.69, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 10, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, + "automatic_partial_off": "REQ", "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { - "method": "SS", - "lighting_primary_space_type": "Sports Arena Playing Area", - "lighting_secondary_space_type": "for a Class II facility", - "lighting_power_density": 2.4, + "method": "CS", + "lighting_primary_space_type": "Storage Room", + "lighting_secondary_space_type": "<50 ft2", + "lighting_power_density": 1.24, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", - "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { - "method": "SS", - "lighting_primary_space_type": "Sports Arena Playing Area", - "lighting_secondary_space_type": "for a Class III facility", - "lighting_power_density": 1.8, + "method": "CS", + "lighting_primary_space_type": "Storage Room", + "lighting_secondary_space_type": "all other storage rooms", + "lighting_power_density": 0.63, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, + "automatic_partial_off": "REQ", "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { - "method": "SS", - "lighting_primary_space_type": "Sports Arena Playing Area", - "lighting_secondary_space_type": "for a Class IV facility", - "lighting_power_density": 1.2, + "method": "CS", + "lighting_primary_space_type": "Storage Room", + "lighting_secondary_space_type": "gt 50 ft2 and lt 1000 ft2", + "lighting_power_density": 0.63, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", + "automatic_full_off": "REQ", + "scheduled_shutoff": null, "annotation": null }, { - "method": "SS", - "lighting_primary_space_type": "Warehouse storage Area", - "lighting_secondary_space_type": "for medium to bulky, palletized items", - "lighting_power_density": 0.58, + "method": "CS", + "lighting_primary_space_type": "Vehicular Maintenance Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.67, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", + "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { - "method": "SS", - "lighting_primary_space_type": "Warehouse storage Area", - "lighting_secondary_space_type": "for smaller, hand-carried items", - "lighting_power_density": 0.95, + "method": "CS", + "lighting_primary_space_type": "Workshop", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.59, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", + "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null @@ -1497,6 +1385,48 @@ "scheduled_shutoff": null, "annotation": null }, + { + "method": "SS", + "lighting_primary_space_type": "Facility For The Visually Impaired", + "lighting_secondary_space_type": "in a chapel (used primarily by residents)", + "lighting_power_density": 2.21, + "lighting_power_density_unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Facility For The Visually Impaired", + "lighting_secondary_space_type": "in a recreation room/common living room (and not used primarily by staff)", + "lighting_power_density": 2.41, + "lighting_power_density_unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Facility For The Visually Impaired", + "lighting_secondary_space_type": "in a recreation room/common living room (and not used primarily by staff)", + "lighting_power_density": 2.41, + "lighting_power_density_unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, { "method": "SS", "lighting_primary_space_type": "Fire Station Sleeping Quarters", @@ -1513,27 +1443,41 @@ }, { "method": "SS", - "lighting_primary_space_type": "Performing Arts Theater Dressing Room", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.61, + "lighting_primary_space_type": "Gymnasium/fitness Center", + "lighting_secondary_space_type": "in a playing area", + "lighting_power_density": 1.2, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "REQ", - "scheduled_shutoff": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Post Office Sorting Area", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.94, + "lighting_primary_space_type": "Gymnasium/fitness Center", + "lighting_secondary_space_type": "in an exercise area", + "lighting_power_density": 0.72, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "in a medical supply room", + "lighting_power_density": 0.74, + "lighting_power_density_unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": "REQ", "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", @@ -1541,11 +1485,11 @@ }, { "method": "SS", - "lighting_primary_space_type": "Transportation Facility", - "lighting_secondary_space_type": "in a baggage/carousel area", - "lighting_power_density": 0.53, + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "in a nurse s station", + "lighting_power_density": 0.71, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1555,11 +1499,11 @@ }, { "method": "SS", - "lighting_primary_space_type": "Facility For The Visually Impaired", - "lighting_secondary_space_type": "in a chapel (used primarily by residents)", - "lighting_power_density": 2.21, + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "in a nursery", + "lighting_power_density": 0.88, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1569,11 +1513,11 @@ }, { "method": "SS", - "lighting_primary_space_type": "Manufacturing Facility", - "lighting_secondary_space_type": "in a detailed manufacturing area", - "lighting_power_density": 1.29, + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "in a patient room", + "lighting_power_density": 0.62, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1583,23 +1527,79 @@ }, { "method": "SS", - "lighting_primary_space_type": "Retail Facilities", - "lighting_secondary_space_type": "in a dressing/fitting room", - "lighting_power_density": 0.71, + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "in a physical therapy room", + "lighting_power_density": 0.91, + "lighting_power_density_unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "in a recovery room", + "lighting_power_density": 1.15, + "lighting_power_density_unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "in an exam/treatment room", + "lighting_power_density": 1.66, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "REQ", - "scheduled_shutoff": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Religious Buildings", - "lighting_secondary_space_type": "in a fellowship hall", - "lighting_power_density": 0.64, + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "in an imaging room", + "lighting_power_density": 1.51, + "lighting_power_density_unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "in an operating room", + "lighting_power_density": 2.48, + "lighting_power_density_unit": "W/ft2", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Library", + "lighting_secondary_space_type": "in a reading area", + "lighting_power_density": 1.06, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1611,11 +1611,25 @@ }, { "method": "SS", - "lighting_primary_space_type": "Museum", - "lighting_secondary_space_type": "in a general exhibition area", - "lighting_power_density": 1.05, + "lighting_primary_space_type": "Library", + "lighting_secondary_space_type": "in the stacks", + "lighting_power_density": 1.71, + "lighting_power_density_unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Manufacturing Facility", + "lighting_secondary_space_type": "in a detailed manufacturing area", + "lighting_power_density": 1.29, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1653,11 +1667,11 @@ }, { "method": "SS", - "lighting_primary_space_type": "Retail Facilities", - "lighting_secondary_space_type": "in a mall concourse", - "lighting_power_density": 1.1, + "lighting_primary_space_type": "Manufacturing Facility", + "lighting_secondary_space_type": "in an equipment room", + "lighting_power_density": 0.74, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1667,23 +1681,23 @@ }, { "method": "SS", - "lighting_primary_space_type": "Healthcare Facility", - "lighting_secondary_space_type": "in a medical supply room", - "lighting_power_density": 0.74, + "lighting_primary_space_type": "Manufacturing Facility", + "lighting_secondary_space_type": "in an extra high bay area (>50 ft floor-to-ceiling height)", + "lighting_power_density": 1.05, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", + "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Healthcare Facility", - "lighting_secondary_space_type": "in a nurse s station", - "lighting_power_density": 0.71, + "lighting_primary_space_type": "Museum", + "lighting_secondary_space_type": "in a general exhibition area", + "lighting_power_density": 1.05, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1695,9 +1709,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Healthcare Facility", - "lighting_secondary_space_type": "in a nursery", - "lighting_power_density": 0.88, + "lighting_primary_space_type": "Museum", + "lighting_secondary_space_type": "in a restoration room", + "lighting_power_density": 1.02, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1709,51 +1723,51 @@ }, { "method": "SS", - "lighting_primary_space_type": "Healthcare Facility", - "lighting_secondary_space_type": "in a patient room", - "lighting_power_density": 0.62, + "lighting_primary_space_type": "None", + "lighting_secondary_space_type": "None", + "lighting_power_density": 0, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", - "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, "automatic_partial_off": null, - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", + "automatic_full_off": null, + "scheduled_shutoff": null, "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Healthcare Facility", - "lighting_secondary_space_type": "in a physical therapy room", - "lighting_power_density": 0.91, + "lighting_primary_space_type": "Performing Arts Theater Dressing Room", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.61, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", + "automatic_full_off": "REQ", + "scheduled_shutoff": null, "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Gymnasium/fitness Center", - "lighting_secondary_space_type": "in a playing area", - "lighting_power_density": 1.2, + "lighting_primary_space_type": "Post Office Sorting Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.94, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, + "automatic_partial_off": "REQ", "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Library", - "lighting_secondary_space_type": "in a reading area", - "lighting_power_density": 1.06, + "lighting_primary_space_type": "Religious Buildings", + "lighting_secondary_space_type": "a worship/pulpit/choir area", + "lighting_power_density": 1.53, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1765,11 +1779,11 @@ }, { "method": "SS", - "lighting_primary_space_type": "Healthcare Facility", - "lighting_secondary_space_type": "in a recovery room", - "lighting_power_density": 1.15, + "lighting_primary_space_type": "Religious Buildings", + "lighting_secondary_space_type": "in a fellowship hall", + "lighting_power_density": 0.64, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1779,13 +1793,13 @@ }, { "method": "SS", - "lighting_primary_space_type": "Facility For The Visually Impaired", - "lighting_secondary_space_type": "in a recreation room/common living room (and not used primarily by staff)", - "lighting_power_density": 2.41, + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (Type 1)", + "lighting_power_density": 0.6, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": null, - "automatic_daylight_responsive_controls_for_toplighting": null, + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, "automatic_full_off": null, "scheduled_shutoff": null, @@ -1793,13 +1807,13 @@ }, { "method": "SS", - "lighting_primary_space_type": "Facility For The Visually Impaired", - "lighting_secondary_space_type": "in a recreation room/common living room (and not used primarily by staff)", - "lighting_power_density": 2.41, + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (Type 2)", + "lighting_power_density": 0.6, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": null, - "automatic_daylight_responsive_controls_for_toplighting": null, + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, "automatic_full_off": null, "scheduled_shutoff": null, @@ -1807,53 +1821,53 @@ }, { "method": "SS", - "lighting_primary_space_type": "Museum", - "lighting_secondary_space_type": "in a restoration room", - "lighting_power_density": 1.02, + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (Type 3)", + "lighting_power_density": 1.4, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", + "automatic_full_off": null, + "scheduled_shutoff": null, "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Transportation Facility", - "lighting_secondary_space_type": "in an airport concourse", - "lighting_power_density": 0.36, + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (Type 4)", + "lighting_power_density": 2.5, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", + "automatic_full_off": null, + "scheduled_shutoff": null, "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Manufacturing Facility", - "lighting_secondary_space_type": "in an equipment room", - "lighting_power_density": 0.74, + "lighting_primary_space_type": "Retail Facilities", + "lighting_secondary_space_type": "in a dressing/fitting room", + "lighting_power_density": 0.71, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", + "automatic_full_off": "REQ", + "scheduled_shutoff": null, "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Healthcare Facility", - "lighting_secondary_space_type": "in an exam/treatment room", - "lighting_power_density": 1.66, + "lighting_primary_space_type": "Retail Facilities", + "lighting_secondary_space_type": "in a mall concourse", + "lighting_power_density": 1.1, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 8, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1863,9 +1877,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Gymnasium/fitness Center", - "lighting_secondary_space_type": "in an exercise area", - "lighting_power_density": 0.72, + "lighting_primary_space_type": "Sports Arena Playing Area", + "lighting_secondary_space_type": "for a Class I facility", + "lighting_power_density": 3.68, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1877,9 +1891,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Manufacturing Facility", - "lighting_secondary_space_type": "in an extra high bay area (>50 ft floor-to-ceiling height)", - "lighting_power_density": 1.05, + "lighting_primary_space_type": "Sports Arena Playing Area", + "lighting_secondary_space_type": "for a Class II facility", + "lighting_power_density": 2.4, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1891,13 +1905,13 @@ }, { "method": "SS", - "lighting_primary_space_type": "Healthcare Facility", - "lighting_secondary_space_type": "in an imaging room", - "lighting_power_density": 1.51, + "lighting_primary_space_type": "Sports Arena Playing Area", + "lighting_secondary_space_type": "for a Class III facility", + "lighting_power_density": 1.8, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": null, - "automatic_daylight_responsive_controls_for_toplighting": null, + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", @@ -1905,13 +1919,13 @@ }, { "method": "SS", - "lighting_primary_space_type": "Healthcare Facility", - "lighting_secondary_space_type": "in an operating room", - "lighting_power_density": 2.48, + "lighting_primary_space_type": "Sports Arena Playing Area", + "lighting_secondary_space_type": "for a Class IV facility", + "lighting_power_density": 1.2, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": null, - "automatic_daylight_responsive_controls_for_toplighting": null, + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", @@ -1919,86 +1933,72 @@ }, { "method": "SS", - "lighting_primary_space_type": "Library", - "lighting_secondary_space_type": "in the stacks", - "lighting_power_density": 1.71, + "lighting_primary_space_type": "Transportation Facility", + "lighting_secondary_space_type": "at a terminal ticket counter", + "lighting_power_density": 0.8, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", + "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Sales Additional (Type 1)", - "lighting_power_density": 0.6, + "lighting_primary_space_type": "Transportation Facility", + "lighting_secondary_space_type": "in a baggage/carousel area", + "lighting_power_density": 0.53, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": null, - "scheduled_shutoff": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Sales Additional (Type 2)", - "lighting_power_density": 0.6, + "lighting_primary_space_type": "Transportation Facility", + "lighting_secondary_space_type": "in an airport concourse", + "lighting_power_density": 0.36, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": null, - "scheduled_shutoff": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Sales Additional (Type 3)", - "lighting_power_density": 1.4, + "lighting_primary_space_type": "Warehouse storage Area", + "lighting_secondary_space_type": "for medium to bulky, palletized items", + "lighting_power_density": 0.58, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, - "automatic_full_off": null, - "scheduled_shutoff": null, + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Sales Additional (Type 4)", - "lighting_power_density": 2.5, + "lighting_primary_space_type": "Warehouse storage Area", + "lighting_secondary_space_type": "for smaller, hand-carried items", + "lighting_power_density": 0.95, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, - "automatic_full_off": null, - "scheduled_shutoff": null, - "annotation": null - }, - { - "method": "SS", - "lighting_primary_space_type": "None", - "lighting_secondary_space_type": "None", - "lighting_power_density": 0, - "lighting_power_density_unit": "W/ft2", - "rcr_threshold": null, - "automatic_daylight_responsive_controls_for_sidelighting": null, - "automatic_daylight_responsive_controls_for_toplighting": null, - "automatic_partial_off": null, - "automatic_full_off": null, - "scheduled_shutoff": null, + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", "annotation": null } ] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.json b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.json index 426756789d..0f46fcac23 100644 --- a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.json +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2016.json @@ -461,20 +461,6 @@ "scheduled_shutoff": "ADD2", "annotation": null }, - { - "method": "CS", - "lighting_primary_space_type": "Storage Room", - "lighting_secondary_space_type": "<50 Ft2", - "lighting_power_density": 0.97, - "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": null, - "automatic_daylight_responsive_controls_for_toplighting": null, - "automatic_partial_off": null, - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", - "annotation": null - }, { "method": "CS", "lighting_primary_space_type": "Atrium", @@ -503,20 +489,6 @@ "scheduled_shutoff": "ADD2", "annotation": null }, - { - "method": "CS", - "lighting_primary_space_type": "Storage Room", - "lighting_secondary_space_type": "gt 50 Ft2 And lt 1000 Ft2", - "lighting_power_density": 0.46, - "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", - "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, - "automatic_full_off": "REQ", - "scheduled_shutoff": null, - "annotation": null - }, { "method": "CS", "lighting_primary_space_type": "Audience Seating Area", @@ -533,123 +505,95 @@ }, { "method": "CS", - "lighting_primary_space_type": "Classroom/lecture Hall/training Room", - "lighting_secondary_space_type": "All Other Classrooms/lecture Halls/training Rooms", - "lighting_power_density": 0.92, - "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", - "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, - "automatic_full_off": "REQ", - "scheduled_shutoff": null, - "annotation": null - }, - { - "method": "CS", - "lighting_primary_space_type": "Corridor", - "lighting_secondary_space_type": "All Other Corridors", - "lighting_power_density": 0.66, + "lighting_primary_space_type": "Audience Seating Area", + "lighting_secondary_space_type": "Auditorium", + "lighting_power_density": 0.63, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": null, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": "REQ", - "automatic_full_off": "ADD2", + "automatic_full_off": null, "scheduled_shutoff": "ADD2", - "annotation": "rcr_threshold: width<8 ft" + "annotation": "ADD2" }, { "method": "CS", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "All Other Dining Areas", - "lighting_power_density": 0.63, + "lighting_primary_space_type": "Audience Seating Area", + "lighting_secondary_space_type": "Convention Center", + "lighting_power_density": 0.82, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, - "automatic_full_off": "ADD2", + "automatic_partial_off": "REQ", + "automatic_full_off": null, "scheduled_shutoff": "ADD2", - "annotation": null + "annotation": "ADD2" }, { "method": "CS", - "lighting_primary_space_type": "Laboratory", - "lighting_secondary_space_type": "All Other Laboratories", - "lighting_power_density": 1.45, + "lighting_primary_space_type": "Audience Seating Area", + "lighting_secondary_space_type": "Gymnasium", + "lighting_power_density": 0.65, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, - "automatic_full_off": "ADD2", + "automatic_partial_off": "REQ", + "automatic_full_off": null, "scheduled_shutoff": "ADD2", - "annotation": null + "annotation": "ADD2" }, { "method": "CS", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "All Other Lobbies", - "lighting_power_density": 1, + "lighting_primary_space_type": "Audience Seating Area", + "lighting_secondary_space_type": "Motion Picture Theater", + "lighting_power_density": 1.14, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": "REQ", - "automatic_full_off": "ADD2", + "automatic_full_off": null, "scheduled_shutoff": "ADD2", - "annotation": null + "annotation": "ADD2" }, { "method": "CS", - "lighting_primary_space_type": "Lounge/Breakroom", - "lighting_secondary_space_type": "All Other Lounges/breakrooms", - "lighting_power_density": 0.62, + "lighting_primary_space_type": "Audience Seating Area", + "lighting_secondary_space_type": "Penitentiary", + "lighting_power_density": 0.28, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, - "automatic_full_off": "REQ", - "scheduled_shutoff": null, - "annotation": null + "automatic_partial_off": "REQ", + "automatic_full_off": null, + "scheduled_shutoff": "ADD2", + "annotation": "ADD2" }, { "method": "CS", - "lighting_primary_space_type": "Restroom", - "lighting_secondary_space_type": "All Other Restrooms", - "lighting_power_density": 0.85, + "lighting_primary_space_type": "Audience Seating Area", + "lighting_secondary_space_type": "Performing Arts Theater", + "lighting_power_density": 2.03, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", - "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, - "automatic_full_off": "REQ", - "scheduled_shutoff": null, - "annotation": null - }, - { - "method": "CS", - "lighting_primary_space_type": "Storage Room", - "lighting_secondary_space_type": "All Other Storage Rooms", - "lighting_power_density": 0.46, - "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": "REQ", - "automatic_full_off": "ADD2", + "automatic_full_off": null, "scheduled_shutoff": "ADD2", - "annotation": null + "annotation": "ADD2" }, { "method": "CS", "lighting_primary_space_type": "Audience Seating Area", - "lighting_secondary_space_type": "Auditorium", - "lighting_power_density": 0.63, + "lighting_secondary_space_type": "Religious Facility", + "lighting_power_density": 1.53, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": "REQ", @@ -659,25 +603,25 @@ }, { "method": "CS", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "Bar/lounge Or Leisure Dining", - "lighting_power_density": 0.93, + "lighting_primary_space_type": "Audience Seating Area", + "lighting_secondary_space_type": "Sports Arena", + "lighting_power_density": 0.43, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, - "automatic_full_off": "ADD2", + "automatic_partial_off": "REQ", + "automatic_full_off": null, "scheduled_shutoff": "ADD2", - "annotation": null + "annotation": "ADD2" }, { "method": "CS", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "Cafeteria Or Fast Food Dining", - "lighting_power_density": 0.63, + "lighting_primary_space_type": "Banking Activity Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.86, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -687,39 +631,39 @@ }, { "method": "CS", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "Elevator", - "lighting_power_density": 0.69, + "lighting_primary_space_type": "Breakroom", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.62, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", + "automatic_partial_off": "REQ", + "automatic_full_off": null, + "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Office", - "lighting_secondary_space_type": "Enclosed And >250 Ft2", - "lighting_power_density": 0.93, + "lighting_primary_space_type": "Classroom/lecture Hall/training Room", + "lighting_secondary_space_type": "All Other Classrooms/lecture Halls/training Rooms", + "lighting_power_density": 0.92, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 8, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", + "automatic_full_off": "REQ", + "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Office", - "lighting_secondary_space_type": "Enclosed And gt 250 Ft2", - "lighting_power_density": 0.93, + "lighting_primary_space_type": "Classroom/lecture Hall/training Room", + "lighting_secondary_space_type": "Penitentiary", + "lighting_power_density": 1.34, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 8, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -729,9 +673,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "Facility For The Visually Impaired (and Not Used Primarily By Staff)", - "lighting_power_density": 2, + "lighting_primary_space_type": "Computer Room", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.33, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -743,25 +687,25 @@ }, { "method": "CS", - "lighting_primary_space_type": "Corridor", - "lighting_secondary_space_type": "Facility For The Visually Impaired (and Not Used Primarily By The Staff)", - "lighting_power_density": 0.92, + "lighting_primary_space_type": "Conference/meeting/multipurpose Room", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.07, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": null, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "Facility For The Visually Impaired (and Not Used Primarily By The Staff)", - "lighting_power_density": 2.03, + "lighting_primary_space_type": "Confinement Cells", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.81, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -771,11 +715,11 @@ }, { "method": "CS", - "lighting_primary_space_type": "Restroom", - "lighting_secondary_space_type": "Facility For The Visually Impaired (and Not Used Primarily By The Staff)", - "lighting_power_density": 0.96, + "lighting_primary_space_type": "Copy/Print Room", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.56, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 8, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -785,79 +729,65 @@ }, { "method": "CS", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "Family Dining", - "lighting_power_density": 0.71, + "lighting_primary_space_type": "Corridor", + "lighting_secondary_space_type": "All Other Corridors", + "lighting_power_density": 0.66, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", - "annotation": null - }, - { - "method": "CS", - "lighting_primary_space_type": "Audience Seating Area", - "lighting_secondary_space_type": "Convention Center", - "lighting_power_density": 0.82, - "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, - "automatic_daylight_responsive_controls_for_sidelighting": null, - "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": "REQ", - "automatic_full_off": null, + "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", - "annotation": "ADD2" + "annotation": "rcr_threshold: width<8 ft" }, { "method": "CS", - "lighting_primary_space_type": "Seating Area, General", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.42, + "lighting_primary_space_type": "Corridor", + "lighting_secondary_space_type": "Facility For The Visually Impaired (and Not Used Primarily By The Staff)", + "lighting_power_density": 0.92, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, - "automatic_daylight_responsive_controls_for_sidelighting": null, + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": "REQ", - "automatic_full_off": null, + "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", - "annotation": "ADD2" + "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Audience Seating Area", - "lighting_secondary_space_type": "Gymnasium", - "lighting_power_density": 0.65, + "lighting_primary_space_type": "Corridor", + "lighting_secondary_space_type": "Hospital", + "lighting_power_density": 0.92, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": null, + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", - "automatic_full_off": null, + "automatic_partial_off": "ADD2", + "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", - "annotation": "ADD2" + "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Audience Seating Area", - "lighting_secondary_space_type": "Motion Picture Theater", - "lighting_power_density": 1.14, + "lighting_primary_space_type": "Corridor", + "lighting_secondary_space_type": "Manufacturing Facility", + "lighting_power_density": 0.29, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, - "automatic_daylight_responsive_controls_for_sidelighting": null, + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", - "automatic_full_off": null, + "automatic_partial_off": null, + "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", - "annotation": "ADD2" + "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Banking Activity Area", + "lighting_primary_space_type": "Courtroom", "lighting_secondary_space_type": "General", - "lighting_power_density": 0.86, + "lighting_power_density": 1.39, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -869,23 +799,23 @@ }, { "method": "CS", - "lighting_primary_space_type": "Breakroom", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.62, + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "All Other Dining Areas", + "lighting_power_density": 0.63, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", - "automatic_full_off": null, - "scheduled_shutoff": null, + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Computer Room", - "lighting_secondary_space_type": "General", - "lighting_power_density": 1.33, + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "Bar/lounge Or Leisure Dining", + "lighting_power_density": 0.93, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -897,25 +827,25 @@ }, { "method": "CS", - "lighting_primary_space_type": "Conference/meeting/multipurpose Room", - "lighting_secondary_space_type": "General", - "lighting_power_density": 1.07, + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "Cafeteria Or Fast Food Dining", + "lighting_power_density": 0.63, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "REQ", - "scheduled_shutoff": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Confinement Cells", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.81, + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "Facility For The Visually Impaired (and Not Used Primarily By Staff)", + "lighting_power_density": 2, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -925,23 +855,23 @@ }, { "method": "CS", - "lighting_primary_space_type": "Copy/Print Room", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.56, + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "Family Dining", + "lighting_power_density": 0.71, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "REQ", - "scheduled_shutoff": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Courtroom", - "lighting_secondary_space_type": "General", - "lighting_power_density": 1.39, + "lighting_primary_space_type": "Dining Area", + "lighting_secondary_space_type": "Penitentiary", + "lighting_power_density": 0.96, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1009,11 +939,11 @@ }, { "method": "CS", - "lighting_primary_space_type": "Laundry/washing Area", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.43, + "lighting_primary_space_type": "Laboratory", + "lighting_secondary_space_type": "All Other Laboratories", + "lighting_power_density": 1.45, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1023,13 +953,27 @@ }, { "method": "CS", - "lighting_primary_space_type": "Loading Dock, Interior", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.58, + "lighting_primary_space_type": "Laboratory", + "lighting_secondary_space_type": "In Or As A Classroom", + "lighting_power_density": 1.2, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Laundry/washing Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.43, + "lighting_power_density_unit": "W/ft2", + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", @@ -1037,37 +981,37 @@ }, { "method": "CS", - "lighting_primary_space_type": "Locker Room", + "lighting_primary_space_type": "Loading Dock, Interior", "lighting_secondary_space_type": "General", - "lighting_power_density": 0.48, + "lighting_power_density": 0.58, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "REQ", - "scheduled_shutoff": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Parking Area, Interior", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.14, + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "All Other Lobbies", + "lighting_power_density": 1, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, - "automatic_daylight_responsive_controls_for_sidelighting": null, - "automatic_daylight_responsive_controls_for_toplighting": null, - "automatic_partial_off": null, - "automatic_full_off": null, - "scheduled_shutoff": null, - "annotation": "See Section 9.4.1.2" + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Pharmacy Area", - "lighting_secondary_space_type": "General", - "lighting_power_density": 1.34, + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "Elevator", + "lighting_power_density": 0.69, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1079,12 +1023,12 @@ }, { "method": "CS", - "lighting_primary_space_type": "Sales Area", - "lighting_secondary_space_type": "General", - "lighting_power_density": 1.22, + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "Facility For The Visually Impaired (and Not Used Primarily By The Staff)", + "lighting_power_density": 2.03, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 3, - "automatic_daylight_responsive_controls_for_sidelighting": null, + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, "automatic_full_off": "ADD2", @@ -1093,73 +1037,73 @@ }, { "method": "CS", - "lighting_primary_space_type": "Stairway", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.58, + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "Hotel", + "lighting_power_density": 1.06, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 10, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", + "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Stairwell", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.58, + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "Motion Picture Theater", + "lighting_power_density": 0.45, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 10, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", + "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Vehicular Maintenance Area", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.56, + "lighting_primary_space_type": "Lobby", + "lighting_secondary_space_type": "Performing Arts Theater", + "lighting_power_density": 1.7, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, + "automatic_partial_off": "REQ", "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Workshop", + "lighting_primary_space_type": "Locker Room", "lighting_secondary_space_type": "General", - "lighting_power_density": 1.14, + "lighting_power_density": 0.48, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", + "automatic_full_off": "REQ", + "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Audience Seating Area", - "lighting_secondary_space_type": "Penitentiary", - "lighting_power_density": 0.28, + "lighting_primary_space_type": "Lounge/Breakroom", + "lighting_secondary_space_type": "All Other Lounges/breakrooms", + "lighting_power_density": 0.62, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, - "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", - "automatic_full_off": null, - "scheduled_shutoff": "ADD2", - "annotation": "ADD2" + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null }, { "method": "CS", @@ -1177,23 +1121,37 @@ }, { "method": "CS", - "lighting_primary_space_type": "Corridor", - "lighting_secondary_space_type": "Hospital", - "lighting_power_density": 0.92, + "lighting_primary_space_type": "Office", + "lighting_secondary_space_type": "Enclosed And >250 Ft2", + "lighting_power_density": 0.93, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": null, + "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "ADD2", + "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "Hotel", - "lighting_power_density": 1.06, + "lighting_primary_space_type": "Office", + "lighting_secondary_space_type": "Enclosed And gt 250 Ft2", + "lighting_power_density": 0.93, + "lighting_power_density_unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Office", + "lighting_secondary_space_type": "Open Plan", + "lighting_power_density": 0.81, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1205,40 +1163,68 @@ }, { "method": "CS", - "lighting_primary_space_type": "Audience Seating Area", - "lighting_secondary_space_type": "Performing Arts Theater", - "lighting_power_density": 2.03, + "lighting_primary_space_type": "Parking Area, Interior", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.14, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 8, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": null, - "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, "automatic_full_off": null, - "scheduled_shutoff": "ADD2", - "annotation": "ADD2" + "scheduled_shutoff": null, + "annotation": "See Section 9.4.1.2" }, { "method": "CS", - "lighting_primary_space_type": "Laboratory", - "lighting_secondary_space_type": "In Or As A Classroom", - "lighting_power_density": 1.2, + "lighting_primary_space_type": "Pharmacy Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.34, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", + "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Corridor", - "lighting_secondary_space_type": "Manufacturing Facility", - "lighting_power_density": 0.29, + "lighting_primary_space_type": "Restroom", + "lighting_secondary_space_type": "All Other Restrooms", + "lighting_power_density": 0.85, + "lighting_power_density_unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Restroom", + "lighting_secondary_space_type": "Facility For The Visually Impaired (and Not Used Primarily By The Staff)", + "lighting_power_density": 0.96, + "lighting_power_density_unit": "W/ft2", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "CS", + "lighting_primary_space_type": "Sales Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.22, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": null, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "rcr_threshold": 3, + "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, "automatic_full_off": "ADD2", @@ -1247,9 +1233,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Audience Seating Area", - "lighting_secondary_space_type": "Religious Facility", - "lighting_power_density": 1.53, + "lighting_primary_space_type": "Seating Area, General", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.42, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": null, @@ -1261,55 +1247,41 @@ }, { "method": "CS", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "Motion Picture Theater", - "lighting_power_density": 0.45, + "lighting_primary_space_type": "Stairway", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.58, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 10, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, + "automatic_partial_off": "REQ", "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Office", - "lighting_secondary_space_type": "Open Plan", - "lighting_power_density": 0.81, + "lighting_primary_space_type": "Stairwell", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.58, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 10, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, + "automatic_partial_off": "REQ", "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Classroom/lecture Hall/training Room", - "lighting_secondary_space_type": "Penitentiary", - "lighting_power_density": 1.34, - "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", - "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, - "automatic_full_off": "REQ", - "scheduled_shutoff": null, - "annotation": null - }, - { - "method": "CS", - "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "Penitentiary", - "lighting_power_density": 0.96, + "lighting_primary_space_type": "Storage Room", + "lighting_secondary_space_type": "<50 Ft2", + "lighting_power_density": 0.97, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", - "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", @@ -1317,9 +1289,9 @@ }, { "method": "CS", - "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "Performing Arts Theater", - "lighting_power_density": 1.7, + "lighting_primary_space_type": "Storage Room", + "lighting_secondary_space_type": "All Other Storage Rooms", + "lighting_power_density": 0.46, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1331,23 +1303,23 @@ }, { "method": "CS", - "lighting_primary_space_type": "Audience Seating Area", - "lighting_secondary_space_type": "Sports Arena", - "lighting_power_density": 0.43, + "lighting_primary_space_type": "Storage Room", + "lighting_secondary_space_type": "gt 50 Ft2 And lt 1000 Ft2", + "lighting_power_density": 0.46, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, - "automatic_daylight_responsive_controls_for_sidelighting": null, + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", - "automatic_full_off": null, - "scheduled_shutoff": "ADD2", - "annotation": "ADD2" + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null }, { - "method": "SS", - "lighting_primary_space_type": "Transportation Facility", - "lighting_secondary_space_type": "Airport Concourse", - "lighting_power_density": 0.31, + "method": "CS", + "lighting_primary_space_type": "Vehicular Maintenance Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.56, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1358,12 +1330,12 @@ "annotation": null }, { - "method": "SS", - "lighting_primary_space_type": "Transportation Facility", - "lighting_secondary_space_type": "Baggage/carousel Area", - "lighting_power_density": 0.46, + "method": "CS", + "lighting_primary_space_type": "Workshop", + "lighting_secondary_space_type": "General", + "lighting_power_density": 1.14, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1373,9 +1345,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Facility For The Visually Impaired", - "lighting_secondary_space_type": "Chapel (used Primarily By Residents)", - "lighting_power_density": 1.06, + "lighting_primary_space_type": "Automotive", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.56, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1387,9 +1359,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Sports Arena-playing Area", - "lighting_secondary_space_type": "Class I Facility", - "lighting_power_density": 2.47, + "lighting_primary_space_type": "Convention Center-exhibit Space", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.88, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1401,23 +1373,23 @@ }, { "method": "SS", - "lighting_primary_space_type": "Sports Arena-playing Area", - "lighting_secondary_space_type": "Class II Facility", - "lighting_power_density": 1.96, + "lighting_primary_space_type": "Dormitory-living Quarters", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.54, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", - "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, "automatic_partial_off": null, - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", + "automatic_full_off": null, + "scheduled_shutoff": null, "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Sports Arena-playing Area", - "lighting_secondary_space_type": "Class Iii Facility", - "lighting_power_density": 1.7, + "lighting_primary_space_type": "Facility For The Visually Impaired", + "lighting_secondary_space_type": "Chapel (used Primarily By Residents)", + "lighting_power_density": 1.06, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1429,11 +1401,11 @@ }, { "method": "SS", - "lighting_primary_space_type": "Sports Arena-playing Area", - "lighting_secondary_space_type": "Class Iv Facility", - "lighting_power_density": 1.13, + "lighting_primary_space_type": "Facility For The Visually Impaired", + "lighting_secondary_space_type": "Recreation Room/common Living Room (and Not Used Primarily By Staff)", + "lighting_power_density": 1.8, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1443,39 +1415,39 @@ }, { "method": "SS", - "lighting_primary_space_type": "Manufacturing Facility", - "lighting_secondary_space_type": "Detailed Manufacturing Area", - "lighting_power_density": 0.93, + "lighting_primary_space_type": "Fire Station-sleeping Quarters", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.2, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", - "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, "automatic_partial_off": null, - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", + "automatic_full_off": null, + "scheduled_shutoff": null, "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Retail Facilities", - "lighting_secondary_space_type": "Dressing/Fitting Room", + "lighting_primary_space_type": "Gymnasium/fitness Center", + "lighting_secondary_space_type": "Exercise Area", "lighting_power_density": 0.5, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 8, - "automatic_daylight_responsive_controls_for_sidelighting": null, + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "REQ", - "scheduled_shutoff": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Manufacturing Facility", - "lighting_secondary_space_type": "Equipment Room", - "lighting_power_density": 0.65, + "lighting_primary_space_type": "Gymnasium/fitness Center", + "lighting_secondary_space_type": "Playing Area", + "lighting_power_density": 0.82, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1499,13 +1471,13 @@ }, { "method": "SS", - "lighting_primary_space_type": "Gymnasium/fitness Center", - "lighting_secondary_space_type": "Exercise Area", - "lighting_power_density": 0.5, + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "Imaging Room", + "lighting_power_density": 1.06, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", - "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", @@ -1513,25 +1485,25 @@ }, { "method": "SS", - "lighting_primary_space_type": "Manufacturing Facility", - "lighting_secondary_space_type": "Extra High Bay Area (>50 Ft Floor-to-ceiling Height)", - "lighting_power_density": 1.05, + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "Medical Supply Room", + "lighting_power_density": 0.54, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, + "automatic_partial_off": "REQ", "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Religious Facility", - "lighting_secondary_space_type": "Fellowship Hall", - "lighting_power_density": 0.55, + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "Nurse\u00c3\u0192\u00c2\u00a2\u00c3\u00a2\u00e2\u20ac\u0161\u00c2\u00ac\u00c3\u00a2\u00e2\u20ac\u017e\u00c2\u00a2s Station", + "lighting_power_density": 0.81, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1541,11 +1513,11 @@ }, { "method": "SS", - "lighting_primary_space_type": "Automotive", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.56, + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "Nursery", + "lighting_power_density": 1, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1555,13 +1527,13 @@ }, { "method": "SS", - "lighting_primary_space_type": "Convention Center-exhibit Space", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.88, + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "Operating Room", + "lighting_power_density": 2.17, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", - "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", @@ -1569,70 +1541,70 @@ }, { "method": "SS", - "lighting_primary_space_type": "Dormitory-living Quarters", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.54, + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "Patient Room", + "lighting_power_density": 0.62, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 8, - "automatic_daylight_responsive_controls_for_sidelighting": null, - "automatic_daylight_responsive_controls_for_toplighting": null, + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": null, - "scheduled_shutoff": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Fire Station-sleeping Quarters", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.2, + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "Physical Therapy Room", + "lighting_power_density": 0.84, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": null, - "automatic_daylight_responsive_controls_for_toplighting": null, + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": null, - "scheduled_shutoff": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Performing Arts Theater-dressing Room", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.36, + "lighting_primary_space_type": "Healthcare Facility", + "lighting_secondary_space_type": "Recovery Room", + "lighting_power_density": 1.03, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "REQ", - "scheduled_shutoff": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Post Office-sorting Area", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.68, + "lighting_primary_space_type": "Library", + "lighting_secondary_space_type": "Reading Area", + "lighting_power_density": 0.82, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", + "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Museum", - "lighting_secondary_space_type": "General Exhibition Area", - "lighting_power_density": 1.05, + "lighting_primary_space_type": "Library", + "lighting_secondary_space_type": "Stacks", + "lighting_power_density": 1.2, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, + "automatic_partial_off": "REQ", "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null @@ -1640,8 +1612,8 @@ { "method": "SS", "lighting_primary_space_type": "Manufacturing Facility", - "lighting_secondary_space_type": "High Bay Area (25 To 50 Ft Floor-to-ceiling Height)", - "lighting_power_density": 0.75, + "lighting_secondary_space_type": "Detailed Manufacturing Area", + "lighting_power_density": 0.93, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1653,13 +1625,13 @@ }, { "method": "SS", - "lighting_primary_space_type": "Healthcare Facility", - "lighting_secondary_space_type": "Imaging Room", - "lighting_power_density": 1.06, + "lighting_primary_space_type": "Manufacturing Facility", + "lighting_secondary_space_type": "Equipment Room", + "lighting_power_density": 0.65, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": null, - "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", @@ -1668,8 +1640,8 @@ { "method": "SS", "lighting_primary_space_type": "Manufacturing Facility", - "lighting_secondary_space_type": "Low Bay Area (<25 Ft Floor-to-ceiling Height)", - "lighting_power_density": 0.96, + "lighting_secondary_space_type": "Extra High Bay Area (>50 Ft Floor-to-ceiling Height)", + "lighting_power_density": 1.05, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1681,9 +1653,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Retail Facilities", - "lighting_secondary_space_type": "Mall Concourse", - "lighting_power_density": 0.9, + "lighting_primary_space_type": "Manufacturing Facility", + "lighting_secondary_space_type": "High Bay Area (25 To 50 Ft Floor-to-ceiling Height)", + "lighting_power_density": 0.75, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1695,37 +1667,37 @@ }, { "method": "SS", - "lighting_primary_space_type": "Healthcare Facility", - "lighting_secondary_space_type": "Medical Supply Room", - "lighting_power_density": 0.54, + "lighting_primary_space_type": "Manufacturing Facility", + "lighting_secondary_space_type": "Low Bay Area (<25 Ft Floor-to-ceiling Height)", + "lighting_power_density": 0.96, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", + "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Warehouse-storage Area", - "lighting_secondary_space_type": "Medium To Bulky, Palletized Items", - "lighting_power_density": 0.35, + "lighting_primary_space_type": "Museum", + "lighting_secondary_space_type": "General Exhibition Area", + "lighting_power_density": 1.05, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", + "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Healthcare Facility", - "lighting_secondary_space_type": "Nurse\u00c3\u00a2\u00e2\u201a\u00ac\u00e2\u201e\u00a2s Station", - "lighting_power_density": 0.81, + "lighting_primary_space_type": "Museum", + "lighting_secondary_space_type": "Restoration Room", + "lighting_power_density": 0.85, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1737,39 +1709,53 @@ }, { "method": "SS", - "lighting_primary_space_type": "Healthcare Facility", - "lighting_secondary_space_type": "Nursery", - "lighting_power_density": 1, + "lighting_primary_space_type": "None", + "lighting_secondary_space_type": "None", + "lighting_power_density": 0, + "lighting_power_density_unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Performing Arts Theater-dressing Room", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.36, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", + "automatic_full_off": "REQ", + "scheduled_shutoff": null, "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Healthcare Facility", - "lighting_secondary_space_type": "Operating Room", - "lighting_power_density": 2.17, + "lighting_primary_space_type": "Post Office-sorting Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.68, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, - "automatic_daylight_responsive_controls_for_sidelighting": null, - "automatic_daylight_responsive_controls_for_toplighting": null, - "automatic_partial_off": null, + "rcr_threshold": 4, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Healthcare Facility", - "lighting_secondary_space_type": "Patient Room", - "lighting_power_density": 0.62, + "lighting_primary_space_type": "Religious Facility", + "lighting_secondary_space_type": "Fellowship Hall", + "lighting_power_density": 0.55, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1779,11 +1765,11 @@ }, { "method": "SS", - "lighting_primary_space_type": "Healthcare Facility", - "lighting_secondary_space_type": "Physical Therapy Room", - "lighting_power_density": 0.84, + "lighting_primary_space_type": "Religious Facility", + "lighting_secondary_space_type": "Worship/Pulpit/Choir Area", + "lighting_power_density": 1.53, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1793,9 +1779,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Gymnasium/fitness Center", - "lighting_secondary_space_type": "Playing Area", - "lighting_power_density": 0.82, + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (type 1)", + "lighting_power_density": 0.45, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1807,9 +1793,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Library", - "lighting_secondary_space_type": "Reading Area", - "lighting_power_density": 0.82, + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (type 2)", + "lighting_power_density": 0.45, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1821,11 +1807,11 @@ }, { "method": "SS", - "lighting_primary_space_type": "Healthcare Facility", - "lighting_secondary_space_type": "Recovery Room", - "lighting_power_density": 1.03, + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (type 3)", + "lighting_power_density": 1.05, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1835,11 +1821,11 @@ }, { "method": "SS", - "lighting_primary_space_type": "Facility For The Visually Impaired", - "lighting_secondary_space_type": "Recreation Room/common Living Room (and Not Used Primarily By Staff)", - "lighting_power_density": 1.8, + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (type 4)", + "lighting_power_density": 1.88, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1849,11 +1835,25 @@ }, { "method": "SS", - "lighting_primary_space_type": "Museum", - "lighting_secondary_space_type": "Restoration Room", - "lighting_power_density": 0.85, + "lighting_primary_space_type": "Retail Facilities", + "lighting_secondary_space_type": "Dressing/Fitting Room", + "lighting_power_density": 0.5, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "REQ", + "scheduled_shutoff": null, + "annotation": null + }, + { + "method": "SS", + "lighting_primary_space_type": "Retail Facilities", + "lighting_secondary_space_type": "Mall Concourse", + "lighting_power_density": 0.9, + "lighting_power_density_unit": "W/ft2", + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1863,9 +1863,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Sales Additional (type 1)", - "lighting_power_density": 0.45, + "lighting_primary_space_type": "Sports Arena-playing Area", + "lighting_secondary_space_type": "Class I Facility", + "lighting_power_density": 2.47, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1877,9 +1877,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Sales Additional (type 2)", - "lighting_power_density": 0.45, + "lighting_primary_space_type": "Sports Arena-playing Area", + "lighting_secondary_space_type": "Class II Facility", + "lighting_power_density": 1.96, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1891,9 +1891,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Sales Additional (type 3)", - "lighting_power_density": 1.05, + "lighting_primary_space_type": "Sports Arena-playing Area", + "lighting_secondary_space_type": "Class Iii Facility", + "lighting_power_density": 1.7, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1905,9 +1905,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Sales Additional (type 4)", - "lighting_power_density": 1.88, + "lighting_primary_space_type": "Sports Arena-playing Area", + "lighting_secondary_space_type": "Class Iv Facility", + "lighting_power_density": 1.13, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1919,28 +1919,28 @@ }, { "method": "SS", - "lighting_primary_space_type": "Warehouse-storage Area", - "lighting_secondary_space_type": "Smaller, Hand-carried Items", - "lighting_power_density": 0.69, + "lighting_primary_space_type": "Transportation Facility", + "lighting_secondary_space_type": "Airport Concourse", + "lighting_power_density": 0.31, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", + "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Library", - "lighting_secondary_space_type": "Stacks", - "lighting_power_density": 1.2, + "lighting_primary_space_type": "Transportation Facility", + "lighting_secondary_space_type": "Baggage/carousel Area", + "lighting_power_density": 0.46, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", + "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null @@ -1961,30 +1961,30 @@ }, { "method": "SS", - "lighting_primary_space_type": "Religious Facility", - "lighting_secondary_space_type": "Worship/Pulpit/Choir Area", - "lighting_power_density": 1.53, + "lighting_primary_space_type": "Warehouse-storage Area", + "lighting_secondary_space_type": "Medium To Bulky, Palletized Items", + "lighting_power_density": 0.35, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, + "automatic_partial_off": "REQ", "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "None", - "lighting_secondary_space_type": "None", - "lighting_power_density": 0, + "lighting_primary_space_type": "Warehouse-storage Area", + "lighting_secondary_space_type": "Smaller, Hand-carried Items", + "lighting_power_density": 0.69, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": null, - "automatic_daylight_responsive_controls_for_sidelighting": null, - "automatic_daylight_responsive_controls_for_toplighting": null, - "automatic_partial_off": null, - "automatic_full_off": null, - "scheduled_shutoff": null, + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", "annotation": null } ] \ No newline at end of file diff --git a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2019.json b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2019.json index 76e38875f3..da392a8a6f 100644 --- a/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2019.json +++ b/data/openstudio_standards_data/database_files/level_3_lighting_90_1_2019.json @@ -461,6 +461,20 @@ "scheduled_shutoff": "ADD2", "annotation": null }, + { + "method": "CS", + "lighting_primary_space_type": "Atrium", + "lighting_secondary_space_type": "> 40 ft in height", + "lighting_power_density": 0.6, + "lighting_power_density_unit": "W/ft2", + "rcr_threshold": 11, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", + "annotation": null + }, { "method": "CS", "lighting_primary_space_type": "Atrium", @@ -477,11 +491,11 @@ }, { "method": "CS", - "lighting_primary_space_type": "Atrium", - "lighting_secondary_space_type": "> 40 ft in height", - "lighting_power_density": 0.6, + "lighting_primary_space_type": "Audience Seating Area", + "lighting_secondary_space_type": "All other audience seating areas", + "lighting_power_density": 0.23, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 11, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -589,11 +603,11 @@ }, { "method": "CS", - "lighting_primary_space_type": "Audience Seating Area", - "lighting_secondary_space_type": "All other audience seating areas", - "lighting_power_density": 0.23, + "lighting_primary_space_type": "Banking Activity Area", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.61, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -603,23 +617,23 @@ }, { "method": "CS", - "lighting_primary_space_type": "Banking Activity Area", + "lighting_primary_space_type": "Breakroom", "lighting_secondary_space_type": "General", - "lighting_power_density": 0.61, + "lighting_power_density": 0.59, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", + "automatic_full_off": "REQ", + "scheduled_shutoff": null, "annotation": null }, { "method": "CS", - "lighting_primary_space_type": "Breakroom", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.59, + "lighting_primary_space_type": "Classroom/Lecture Hall/Training Room", + "lighting_secondary_space_type": "All other classrooms/lecture halls/training rooms", + "lighting_power_density": 0.71, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -645,16 +659,16 @@ }, { "method": "CS", - "lighting_primary_space_type": "Classroom/Lecture Hall/Training Room", - "lighting_secondary_space_type": "All other classrooms/lecture halls/training rooms", - "lighting_power_density": 0.71, + "lighting_primary_space_type": "Computer Room", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.94, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "REQ", - "scheduled_shutoff": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", "annotation": null }, { @@ -702,8 +716,8 @@ { "method": "CS", "lighting_primary_space_type": "Corridor", - "lighting_secondary_space_type": "Facility for the visually impaired (and not used primarily by the staff)", - "lighting_power_density": 0.71, + "lighting_secondary_space_type": "All other corridors", + "lighting_power_density": 0.41, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -716,13 +730,13 @@ { "method": "CS", "lighting_primary_space_type": "Corridor", - "lighting_secondary_space_type": "Hospital", + "lighting_secondary_space_type": "Facility for the visually impaired (and not used primarily by the staff)", "lighting_power_density": 0.71, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "ADD2", + "automatic_partial_off": "REQ", "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": "rcr_threshold: width<8 ft" @@ -730,13 +744,13 @@ { "method": "CS", "lighting_primary_space_type": "Corridor", - "lighting_secondary_space_type": "All other corridors", - "lighting_power_density": 0.41, + "lighting_secondary_space_type": "Hospital", + "lighting_power_density": 0.71, "lighting_power_density_unit": "W/ft2", "rcr_threshold": null, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", + "automatic_partial_off": "ADD2", "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": "rcr_threshold: width<8 ft" @@ -755,27 +769,13 @@ "scheduled_shutoff": "ADD2", "annotation": null }, - { - "method": "CS", - "lighting_primary_space_type": "Computer Room", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.94, - "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", - "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", - "annotation": null - }, { "method": "CS", "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "Penitentiary", - "lighting_power_density": 0.42, + "lighting_secondary_space_type": "All other dining areas", + "lighting_power_density": 0.43, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -786,8 +786,8 @@ { "method": "CS", "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "Facility for the visually impaired (and not used primarily by staff)", - "lighting_power_density": 1.27, + "lighting_secondary_space_type": "Bar/lounge or leisure dining", + "lighting_power_density": 0.86, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -800,8 +800,8 @@ { "method": "CS", "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "Bar/lounge or leisure dining", - "lighting_power_density": 0.86, + "lighting_secondary_space_type": "Cafeteria or fast food dining", + "lighting_power_density": 0.4, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -814,8 +814,8 @@ { "method": "CS", "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "Cafeteria or fast food dining", - "lighting_power_density": 0.4, + "lighting_secondary_space_type": "Facility for the visually impaired (and not used primarily by staff)", + "lighting_power_density": 1.27, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -842,10 +842,10 @@ { "method": "CS", "lighting_primary_space_type": "Dining Area", - "lighting_secondary_space_type": "All other dining areas", - "lighting_power_density": 0.43, + "lighting_secondary_space_type": "Penitentiary", + "lighting_power_density": 0.42, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -912,13 +912,13 @@ { "method": "CS", "lighting_primary_space_type": "Laboratory", - "lighting_secondary_space_type": "In or as a classroom", - "lighting_power_density": 1.11, + "lighting_secondary_space_type": "All other laboratories", + "lighting_power_density": 1.33, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", + "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null @@ -926,13 +926,13 @@ { "method": "CS", "lighting_primary_space_type": "Laboratory", - "lighting_secondary_space_type": "All other laboratories", - "lighting_power_density": 1.33, + "lighting_secondary_space_type": "In or as a classroom", + "lighting_power_density": 1.11, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, + "automatic_partial_off": "REQ", "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null @@ -968,8 +968,8 @@ { "method": "CS", "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "Facility for the visually impaired (and not used primarily by the staff)", - "lighting_power_density": 1.69, + "lighting_secondary_space_type": "All other lobbies", + "lighting_power_density": 0.84, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -996,13 +996,13 @@ { "method": "CS", "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "Hotel", - "lighting_power_density": 0.51, + "lighting_secondary_space_type": "Facility for the visually impaired (and not used primarily by the staff)", + "lighting_power_density": 1.69, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, + "automatic_partial_off": "REQ", "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null @@ -1010,8 +1010,8 @@ { "method": "CS", "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "Motion picture theater", - "lighting_power_density": 0.23, + "lighting_secondary_space_type": "Hotel", + "lighting_power_density": 0.51, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1024,13 +1024,13 @@ { "method": "CS", "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "Performing arts theater ", - "lighting_power_density": 1.25, + "lighting_secondary_space_type": "Motion picture theater", + "lighting_power_density": 0.23, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", + "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null @@ -1038,10 +1038,10 @@ { "method": "CS", "lighting_primary_space_type": "Lobby", - "lighting_secondary_space_type": "All other lobbies", - "lighting_power_density": 0.84, + "lighting_secondary_space_type": "Performing arts theater ", + "lighting_power_density": 1.25, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": "REQ", @@ -1066,10 +1066,10 @@ { "method": "CS", "lighting_primary_space_type": "Lounge/Breakroom", - "lighting_secondary_space_type": "Healthcare facility", - "lighting_power_density": 0.42, + "lighting_secondary_space_type": "All other lounges/breakrooms", + "lighting_power_density": 0.59, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1080,10 +1080,10 @@ { "method": "CS", "lighting_primary_space_type": "Lounge/Breakroom", - "lighting_secondary_space_type": "All other lounges/breakrooms", - "lighting_power_density": 0.59, + "lighting_secondary_space_type": "Healthcare facility", + "lighting_power_density": 0.42, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, + "rcr_threshold": 6, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1164,8 +1164,8 @@ { "method": "CS", "lighting_primary_space_type": "Restroom", - "lighting_secondary_space_type": "Facility for the visually impaired (and not used primarily by the staff)", - "lighting_power_density": 1.26, + "lighting_secondary_space_type": "All other restrooms", + "lighting_power_density": 0.63, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1178,8 +1178,8 @@ { "method": "CS", "lighting_primary_space_type": "Restroom", - "lighting_secondary_space_type": "All other restrooms", - "lighting_power_density": 0.63, + "lighting_secondary_space_type": "Facility for the visually impaired (and not used primarily by the staff)", + "lighting_power_density": 1.26, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 8, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1303,9 +1303,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Facility for the Visually Impaired", - "lighting_secondary_space_type": "Chapel (used primarily by residents)", - "lighting_power_density": 0.7, + "lighting_primary_space_type": "Automotive", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.6, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1317,11 +1317,11 @@ }, { "method": "SS", - "lighting_primary_space_type": "Facility for the Visually Impaired", - "lighting_secondary_space_type": "Recreation room/common living room (and not used primarily by staff)", - "lighting_power_density": 1.77, + "lighting_primary_space_type": "Convention Center: Exhibit Space", + "lighting_secondary_space_type": "General", + "lighting_power_density": 0.61, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, @@ -1331,23 +1331,23 @@ }, { "method": "SS", - "lighting_primary_space_type": "Automotive", + "lighting_primary_space_type": "Dormitory: Living Quarters", "lighting_secondary_space_type": "General", - "lighting_power_density": 0.6, + "lighting_power_density": 0.5, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", - "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, "automatic_partial_off": null, - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", + "automatic_full_off": null, + "scheduled_shutoff": null, "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Convention Center: Exhibit Space", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.61, + "lighting_primary_space_type": "Facility for the Visually Impaired", + "lighting_secondary_space_type": "Chapel (used primarily by residents)", + "lighting_power_density": 0.7, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1359,16 +1359,16 @@ }, { "method": "SS", - "lighting_primary_space_type": "Dormitory: Living Quarters", - "lighting_secondary_space_type": "General", - "lighting_power_density": 0.5, + "lighting_primary_space_type": "Facility for the Visually Impaired", + "lighting_secondary_space_type": "Recreation room/common living room (and not used primarily by staff)", + "lighting_power_density": 1.77, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 8, - "automatic_daylight_responsive_controls_for_sidelighting": null, - "automatic_daylight_responsive_controls_for_toplighting": null, + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": null, - "scheduled_shutoff": null, + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", "annotation": null }, { @@ -1665,6 +1665,20 @@ "scheduled_shutoff": "ADD2", "annotation": null }, + { + "method": "SS", + "lighting_primary_space_type": "None", + "lighting_secondary_space_type": "None", + "lighting_power_density": 0, + "lighting_power_density_unit": "W/ft2", + "rcr_threshold": null, + "automatic_daylight_responsive_controls_for_sidelighting": null, + "automatic_daylight_responsive_controls_for_toplighting": null, + "automatic_partial_off": null, + "automatic_full_off": null, + "scheduled_shutoff": null, + "annotation": null + }, { "method": "SS", "lighting_primary_space_type": "Performing Arts Theater: Dressing Room", @@ -1723,23 +1737,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Retail Facilities", - "lighting_secondary_space_type": "Dressing/fitting room", - "lighting_power_density": 0.51, - "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 8, - "automatic_daylight_responsive_controls_for_sidelighting": null, - "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, - "automatic_full_off": "REQ", - "scheduled_shutoff": null, - "annotation": null - }, - { - "method": "SS", - "lighting_primary_space_type": "Retail Facilities", - "lighting_secondary_space_type": "Mall concourse", - "lighting_power_density": 0.82, + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (Retail Area 1)", + "lighting_power_density": 0.45, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1751,9 +1751,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Sports Arena: Playing Area", - "lighting_secondary_space_type": "Class I facility", - "lighting_power_density": 2.94, + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (Retail Area 2)", + "lighting_power_density": 0.45, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1765,9 +1765,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Sports Arena: Playing Area", - "lighting_secondary_space_type": "Class II facility", - "lighting_power_density": 2.01, + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (Retail Area 3)", + "lighting_power_density": 1.05, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1779,9 +1779,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Sports Arena: Playing Area", - "lighting_secondary_space_type": "Class III facility", - "lighting_power_density": 1.3, + "lighting_primary_space_type": "Retail", + "lighting_secondary_space_type": "Sales Additional (Retail Area 4)", + "lighting_power_density": 1.88, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1793,23 +1793,23 @@ }, { "method": "SS", - "lighting_primary_space_type": "Sports Arena: Playing Area", - "lighting_secondary_space_type": "Class IV facility", - "lighting_power_density": 0.86, + "lighting_primary_space_type": "Retail Facilities", + "lighting_secondary_space_type": "Dressing/fitting room", + "lighting_power_density": 0.51, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 4, - "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "rcr_threshold": 8, + "automatic_daylight_responsive_controls_for_sidelighting": null, "automatic_daylight_responsive_controls_for_toplighting": "REQ", "automatic_partial_off": null, - "automatic_full_off": "ADD2", - "scheduled_shutoff": "ADD2", + "automatic_full_off": "REQ", + "scheduled_shutoff": null, "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Transportation Facility", - "lighting_secondary_space_type": "Baggage/carousel area", - "lighting_power_density": 0.39, + "lighting_primary_space_type": "Retail Facilities", + "lighting_secondary_space_type": "Mall concourse", + "lighting_power_density": 0.82, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1821,9 +1821,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Transportation Facility", - "lighting_secondary_space_type": "Airport concourse", - "lighting_power_density": 0.25, + "lighting_primary_space_type": "Sports Arena: Playing Area", + "lighting_secondary_space_type": "Class I facility", + "lighting_power_density": 2.94, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1835,9 +1835,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Transportation Facility", - "lighting_secondary_space_type": "Ticket counter", - "lighting_power_density": 0.51, + "lighting_primary_space_type": "Sports Arena: Playing Area", + "lighting_secondary_space_type": "Class II facility", + "lighting_power_density": 2.01, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1849,37 +1849,37 @@ }, { "method": "SS", - "lighting_primary_space_type": "Warehouse: Storage Area", - "lighting_secondary_space_type": "Medium to bulky, palletized items", - "lighting_power_density": 0.33, + "lighting_primary_space_type": "Sports Arena: Playing Area", + "lighting_secondary_space_type": "Class III facility", + "lighting_power_density": 1.3, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", + "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Warehouse: Storage Area", - "lighting_secondary_space_type": "Smaller, hand-carried items", - "lighting_power_density": 0.69, + "lighting_primary_space_type": "Sports Arena: Playing Area", + "lighting_secondary_space_type": "Class IV facility", + "lighting_power_density": 0.86, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": 6, + "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": "REQ", + "automatic_partial_off": null, "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Sales Additional (Retail Area 1)", - "lighting_power_density": 0.45, + "lighting_primary_space_type": "Transportation Facility", + "lighting_secondary_space_type": "Airport concourse", + "lighting_power_density": 0.25, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1891,9 +1891,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Sales Additional (Retail Area 2)", - "lighting_power_density": 0.45, + "lighting_primary_space_type": "Transportation Facility", + "lighting_secondary_space_type": "Baggage/carousel area", + "lighting_power_density": 0.39, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1905,9 +1905,9 @@ }, { "method": "SS", - "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Sales Additional (Retail Area 3)", - "lighting_power_density": 1.05, + "lighting_primary_space_type": "Transportation Facility", + "lighting_secondary_space_type": "Ticket counter", + "lighting_power_density": 0.51, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", @@ -1919,30 +1919,30 @@ }, { "method": "SS", - "lighting_primary_space_type": "Retail", - "lighting_secondary_space_type": "Sales Additional (Retail Area 4)", - "lighting_power_density": 1.88, + "lighting_primary_space_type": "Warehouse: Storage Area", + "lighting_secondary_space_type": "Medium to bulky, palletized items", + "lighting_power_density": 0.33, "lighting_power_density_unit": "W/ft2", "rcr_threshold": 4, "automatic_daylight_responsive_controls_for_sidelighting": "REQ", "automatic_daylight_responsive_controls_for_toplighting": "REQ", - "automatic_partial_off": null, + "automatic_partial_off": "REQ", "automatic_full_off": "ADD2", "scheduled_shutoff": "ADD2", "annotation": null }, { "method": "SS", - "lighting_primary_space_type": "None", - "lighting_secondary_space_type": "None", - "lighting_power_density": 0, + "lighting_primary_space_type": "Warehouse: Storage Area", + "lighting_secondary_space_type": "Smaller, hand-carried items", + "lighting_power_density": 0.69, "lighting_power_density_unit": "W/ft2", - "rcr_threshold": null, - "automatic_daylight_responsive_controls_for_sidelighting": null, - "automatic_daylight_responsive_controls_for_toplighting": null, - "automatic_partial_off": null, - "automatic_full_off": null, - "scheduled_shutoff": null, + "rcr_threshold": 6, + "automatic_daylight_responsive_controls_for_sidelighting": "REQ", + "automatic_daylight_responsive_controls_for_toplighting": "REQ", + "automatic_partial_off": "REQ", + "automatic_full_off": "ADD2", + "scheduled_shutoff": "ADD2", "annotation": null } ] \ No newline at end of file